HPE P2000 G3 Troubleshooting Guide

Size: px
Start display at page:

Download "HPE P2000 G3 Troubleshooting Guide"

Transcription

1 HPE P2000 G3 Troubleshooting Guide Part Number: Published: July 2016 Edition: 1

2 Contents 1 Troubleshooting HPE P2000 G3...3 Events and LEDs...3 Event Monitoring...3 Events sent as Indications to SMI-S Clients...3 Events requiring FRU replacements...4 LED Indications and Recommended Actions...6 Isolating a host-side connection fault...9 Disk Drives...9 Disk Drive LEDs...10 Disk Error Conditions and Recommended Actions...11 Disk Drive Bay Numbers...13 Drive Status...13 Disk Drive Leftover...14 Vdisk or Disk Group Status...16 Vdisk or Disk Group Quarantined...16 Disk Drive Failure during Reconstruct...18 Vdisk or disk group Member Unavailable...19 Two or Multiple Disk Drive Failure...19 Vdisk or Disk Group Alerts...20 Vdisk or disk group Expansion Frequently Asked Questions (FAQs)...20 Management Controller Issue...21 Restarting the Management Controller...21 Instances when the Management Controller becomes Unresponsive...22 Power Supply Faults and Power Cycle...24 Power Cycle...24 Power Supply Faults and Recommended Actions...25 Chassis Replacement...26 Using the Trust Command...26 Running the trust command...27 After running the trust command Support and other resources...31 Accessing Hewlett Packard Enterprise Support...31 Accessing updates...31 Websites...31 Customer self repair...32 Remote support...32 Documentation feedback Contents

3 1 Troubleshooting HPE P2000 G3 The following section details the events and their descriptions used to troubleshoot HPE P2000 G3: Events and LEDs (page 3) Disk Drives (page 9) Management Controller Issue (page 21) Power Supply Faults and Power Cycle (page 24) Chassis Replacement (page 26) Using the Trust Command (page 26) Events and LEDs Event Monitoring (page 3) Events sent as Indications to SMI-S Clients (page 3) Events requiring FRU replacements (page 4) LED Indications and Recommended Actions (page 6) Event Monitoring Event notification can be set to four different levels: Informational Warning Error Critical INFORMATIONAL used to inform all system events. This level will result in increased messages as all categories of messages will be reported. This level requires regular attention and review to ensure that WARNING (or ERROR or CRITICAL) events are not lost in the resulting expanded event report. WARNING recommended as it signals a problem exists that results in the loss of redundancy. If another similar failure occurs, a system outage (and resulting loss of access to data) occurs. HPE recommends that you investigate and resolve the event promptly. ERROR used to inform failure occurred that might affect data Integrity or system stability. Correct the problem as soon as possible. CRITICAL used to inform failure occurred that might cause a controller to shutdown. Correct the problem immediately. Events sent as Indications to SMI-S Clients If the storage systems SMI-S interface is enabled, the system will send events as indications to SMI-S clients. The SMI-S clients can then monitor the system performance. For information on enabling the SMI-S interface, see Configuring the system in the MSA 1040/2040 SMU Reference Guide on the Hewlett Packard Enterprise Support Center website. For information on the event categories pertaining to Field Replaceable Unit (FRU) assemblies and certain FRU components, see Events sent as indications to SMI-S clients in the MSA Event Descriptions Reference Guide on the Hewlett Packard Enterprise Support Center website. Events and LEDs 3

4 Events requiring FRU replacements Table 1 Events requiring FRU replacements scenarios Event ID FRU 8 HDD See Disk Error Conditions and Recommended Actions (page 11) 39 Controller The sensors monitored a temperature or voltage in the warning range. Verify the following: The system has two power supplies and both are running correctly The ambient temperature is not too warm. The enclosure operating range is 5 40 C (41 F 104 F) A module or blank plate resides in every module slot in the enclosure If none of these conditions apply, replace the controller module that reported the error. 40 Controller The sensors monitored a temperature or voltage in the failure range. Verify the following: The system has two power supplies and both are running correctly The ambient temperature is not too warm. The enclosure operating range is 5 40 C (41 F 104 F) A module or blank plate resides in every module slot in the enclosure If none of these conditions apply, replace the controller module that reported the error. 50 Controller Correctable ECC error in buffer memory. Replace on multiple occurrences. 51 Controller An uncorrectable ECC error occurred in buffer memory. Replace on first occurrence. 55 HDD A disk drive reported a SMART event. Replace on first occurrence. 58 HDD A disk drive detected a serious error, such as a parity error or disk hardware failure. Replace on first occurrence. 62 HDD The indicated global or dedicated spare disk has failed. The drive LED changes to amber. Replace the drive. 65 Controller An uncorrectable ECC error occurred on the buffer memory on startup. Replace on first occurrence. 95 Controller Both controllers in an Active-Active configuration have the same serial number. Replace one of the controllers on first occurrence. 157 Controller A failure occurred when trying to write to the Storage Controller flash chip. Replace on first occurrence. 168 PSU See Power Supply Faults and Recommended Actions (page 25) 204 CompactFlash A failure occurred when trying to write to the CompactFlash. Replace the CompactFlash. 217 Controller A supercapacitor failure occurred on the controller. Replace on first occurrence. 4 Troubleshooting HPE P2000 G3

5 Table 1 Events requiring FRU replacements scenarios (continued) Event ID FRU 218 Controller The supercapacitor pack is nearing end-of-life. Replace on first occurrence. 233 HDD The indicated disk type is invalid and is not enabled in the current configuration. Replace on first occurrence. 235 Controller An enclosure management processor (EMP) detected a serious error. Replace on first occurrence. 239 CompactFlash A timeout occurs while flushing the CompactFlash. Replace the CompactFlash. 240 CompactFlash The CompactFlash hardware detected an error. Replace the CompactFlash. 242 CompactFlash The controller module's CompactFlash card has failed. Replace the CompactFlash. 246 Controller The coin battery is not present or is not properly seated or has reached end-of-life. Replace on first occurrence. 247 Various The FRU ID SEEPROM for the indicated FRU cannot be read. FRU ID data might not be programmed. Replace the FRU indicated. 307 Controller A temperature sensor on a controller FRU detected an over-temperature condition that caused the controller to Verify the following: The system has two power supplies and both are running correctly shutdown. The ambient temperature is not too warm. The enclosure operating range is 5 40 C (41 F 104 F) Obstructions to airflow. A module or blank plate resides in every module slot in the enclosure If none of these conditions apply, replace the controller module that reported the error. 313 Controller The indicated controller module has failed. This event can be ignored for a single-controller configuration. Replace on first occurrence. 314 Various The indicated FRU has failed or is not operating correctly. This event follows some other FRU-specific event indicating a problem. To determine whether the FRU must be replaced, see Verifying component failure in the component's replacement instructions document. 318 Controller A hardware failure occurred: XOR error. Replace on first occurrence. 319 HDD The indicated available disk has failed. Replace on first occurrence. 442 Controller Power-On Self-Test (POST) diagnostics detected a hardware error. Replace on first occurrence. 455 SFP The controller detected that the configured host-port link speed Replace with an SFP that supports a later speed. Events and LEDs 5

6 Table 1 Events requiring FRU replacements scenarios (continued) Event ID FRU exceeded the capability of an FC SFP. 464 SFP A user inserted an unsupported cable or SFP into the indicated controller host port. Replace with a supported SFP. 551 PSU See Power Supply Faults and Recommended Actions (page 25) LED Indications and Recommended Actions Table 2 LED Indications and recommended actions Indicator Status Cause The enclosure front panel Fault/Service Required LED Off Amber System is functioning properly. No action required. A fault condition Verify the following: exists/occurred. If installing The LEDs on the back of an I/O module FRU, the the controller enclosure module has not gone online to narrow the fault to a and likely failed its self-test. FRU, connection, or both The event log for specific information regarding the fault; follow any Recommended Actions If installing an IOM FRU, try removing and reinstalling the new IOM, and check the event log for errors If the previous actions do not resolve the fault, isolate the fault, and contact an authorized service provider for assistance. Replacement is necessary. 6 Troubleshooting HPE P2000 G3

7 Table 2 LED Indications and recommended actions (continued) Indicator Status Cause The enclosure rear panel FRU OK LED On; blinking regularly System is functioning properly. System is booting. No action required. Wait for system to boot. Off The controller module is not powered on. The controller module has failed. Verify the following: The controller module is fully inserted and latched in place, and the enclosure is powered on The event log for specific information regarding the failure The enclosure rear panel Fault/Service Required LED Off Amber; blinking regularly System is functioning properly. No action required. Hardware-controlled Restart this controller power-up error from the other controller using the SMU or the CLI Cache flush error If the previous action Cache self-refresh error does not resolve the fault, remove the controller and reinsert it If the previous actions do not resolve the fault, contact an authorized service provider for assistance. Replace the controller. Connected host port Host Link Status LED On; blinking regularly System is functioning properly. No action required. Events and LEDs 7

8 Table 2 LED Indications and recommended actions (continued) Indicator Status Cause Off The link is down. Check cable connections and reseat if necessary Inspect cables for damage. Replace cable if necessary Defective cable causes fault. Swap cables to determine the fault. Replace cable if necessary Verify that the switch, if any, is operating properly. If possible, test with another port Verify that the HBA is fully seated, and that the PCI slot is powered on and operational In the SMU, review event logs for indicators of a specific fault in a host datapath component; follow any Recommended Actions. Contact an authorized service provider for assistance. A connected port Expansion Port Status LED On System is functioning properly. No action required. Off The link is down. Check cable connections and reseat if necessary Inspect cables for damage. Replace cable if necessary Defective cable causes fault. Swap cables to determine the fault. Replace cable if necessary In the SMU, review event logs for indicators of a specific fault in a host datapath component; follow any Recommended Actions. Contact an authorized service provider for assistance A connected port Network Port Link Status LED On System is functioning properly. No action required. Off The link is down. Use standard networking troubleshooting procedures to isolate faults on the network. 8 Troubleshooting HPE P2000 G3

9 Table 2 LED Indications and recommended actions (continued) Indicator Status Cause The power supply Input Power Source LED On System is functioning properly. No action required. Off The power supply is not Verify that the power receiving adequate power. cable is properly connected and check the power source to which it connects Check that the power supply FRU is firmly locked into position In the SMU, check the event log for specific information regarding the fault; follow any Recommended Actions If the previous action does not resolve or isolate the fault, contact an authorized service provider for assistance The power supply Voltage/Fan Fault/Service Required LED Off On; blinking regularly System is functioning properly. The power supply unit or a fan is operating at an unacceptable voltage/rpm level, or has failed. No action required. When isolating faults in the power supply, remember that the fans in both modules receive power through a common bus on the midplane. If a power supply unit fails, the fans continue to operate normally: Verify the following: The power supply FRU is firmly locked into position The power cable is connected to a power source The power cable is connected to the power supply module Isolating a host-side connection fault Disk Drives If data hosts are having trouble accessing the storage system, and you cannot locate a specific fault or cannot access the event logs, see Isolating a host-side connection fault section in the HPE P2000 G3 FC/iSCSI MSA System User Guide. For more troubleshooting information, see Troubleshooting chapter in the HPE P2000 G3 FC/iSCSI MSA System User Guide. Disk Drive LEDs (page 10) Disk Error Conditions and Recommended Actions (page 11) Disk Drive Bay Numbers (page 13) Disk Drives 9

10 Disk Drive Leftover (page 14) Vdisk or Disk Group Quarantined (page 16) Disk Drive Failure during Reconstruct (page 18) Vdisk or disk group Member Unavailable (page 19) Two or Multiple Disk Drive Failure (page 19) Vdisk or Disk Group Alerts (page 20) Vdisk or disk group Expansion Frequently Asked Questions (FAQs) (page 20) Disk Drive LEDs Figure SFF disk drive Figure LFF disk drive Table 3 LEDs - Disk drive LEDs LED 1 2 Description Fault/UID (amber/blue) Online/Activity (green) 10 Troubleshooting HPE P2000 G3

11 Table 4 LEDs - Disk drive combinations Online/Activity (green) Fault/UID (amber/blue) Description Recommended Action On Off Normal operation. The drive is online, but it is not currently active. No action required. Blinking irregularly Off The drive is active and operating normally. No action required. Off Amber; blinking Offline; the drive is not being Check the event log for specific regularly accessed. A drive error might be information regarding the fault (1 Hz) received for this device. Further investigation is required. Isolate the fault Contact an authorized service On Online; possible I/O activity. A drive provider for assistance Amber; blinking regularly (1 Hz) error might be received for this device. Further investigation is required. Blinking irregularly Amber; blinking regularly (1 Hz) The drive is active, but a drive error might be received for this drive. Further investigation is required. Off Amber; solid Offline; no activity. A failure or critical fault condition is identified for this drive. This activity indicates that the drive is leftover rather than a problem with the drive itself. Off Blue; solid Offline. A management application (SMU) selects the drive. No action required. On or blinking Blue; solid The controller is driving I/O to the drive. A management application (SMU) selects the drive. No action required. Blinking regularly (1 Hz) Off CAUTION: Do not remove the drive. Removing a drive closes the current operation and causes data loss. The drive is rebuilding. No action required. Off Off Either there is no power, the drive is offline, or the drive is not configured. Check that the disk drive is fully inserted and latched in place, and the enclosure is powered on. Disk Error Conditions and Recommended Actions Table 5 Disk error conditions and recommended actions Event 8 reports that the RAID controller can no longer detect the disk. Event 8 reports a media error for the disk. Event 8 reports a hardware error for the disk. Event 8 reports an Illegal Request sense code for a command the disk supports. Recommended Action Reseat the disk. If it does not solve the problem, replace the disk. If all the volumes and Vdisks or disk groups are online and available, then replace the disk. If the drive is marked as Leftover or Failed, and data recovery is needed, see Using the Trust Command (page 26). If all the volumes and Vdisks or disk groups are online and available, then replace the disk. If the drive is marked as Leftover or Failed, and data recovery is needed, see Using the Trust Command (page 26). If all the volumes and Vdisks or disk groups are online and available, then replace the disk. Otherwise, if the drive is marked as Leftover or Disk Drives 11

12 Table 5 Disk error conditions and recommended actions (continued) Recommended Action Failed, and data recovery is needed, see Using the Trust Command (page 26). Event 8 reports that RAID-6 logic intentionally failed the disk. Event 55 reports a SMART error for the disk. At the time, a disk failed, the dynamic spares feature was enabled, and a properly sized disk was available to use as a spare. At the time, a disk failed, the dynamic spares feature was enabled but no properly sized disk was available to use as a spare. At the time, a disk failed, the dynamic spares feature was disabled and no dedicated spare or properly sized global spare was available. Replace the disk. If all the volumes and Vdisks or disk groups are online and available, then replace the disk. If the drive is marked as Leftover or Failed, and data recovery is needed, see Using the Trust Command (page 26). No action required; the system automatically uses that disk to reconstruct the Vdisk or disk group. Replace the failed disk when reconstruction has completed. The best option is to supply an appropriately sized spare so the system can automatically use the new disk to reconstruct the Vdisk or disk group, and replace the failed disk once reconstruction has completed. If that is not possible, and all Vdisks or disk groups are online and your data is available, then replace the failed disk with an appropriately sized disk. Assign the replacement disk as a spare unless dynamic sparing is enabled. The best option is to supply an appropriately sized disk using the SMU or CLI. Assign it as a dedicated Vdisk or disk group spare and let the system automatically reconstruct the Vdisk or disk group, then replace the failed disk once reconstruction is complete. If that is not possible, and all Vdisks or disk groups are online and the data is available, then replace the failed disk with an appropriately sized disk. Assign the replacement disk as a spare. The status of the Vdisk or disk group that originally had the failed disk status is Good. A global Vdisk or disk group (dedicated) spare has been successfully integrated into the Vdisk or disk group and the replacement disk can be assigned as either a global spare or a Vdisk or disk group spare. Use SMU to assign the new disk as either a global spare or a Vdisk or disk group spare. The status of the disk installed is LEFTOVR All the member disks in a Vdisk or disk group contain metadata in the first sectors. The storage system uses the metadata to identify Vdisk or disk group members after restarting or replacing enclosures. This disk was a member of a Vdisk or disk group on another system, and that Vdisk or disk group does not exist on this system. Clear the drive metadata if it is not required for a Vdisk or disk group from another array. If the status of the Vdisk or disk group that The data in the Vdisk or disk group is inaccessible and at risk. Attempt originally had the failed disk status is to recover by reseating the last failed drives. If that does not resolve the OFFL (Offline) or QTOF (Quarantined issue, and data recovery is needed, see Using the Trust Command Offline), one or more disks have failed in (page 26). a RAID-0 Vdisk or disk group. Two or more disks have failed in a RAID-1, 3, or 5 Vdisk or disk group. Three or more disks have failed in a RAID-6 Vdisk or disk group. The status of the Vdisk or disk group that originally had the failed disk indicates that the Vdisk or disk group is being rebuilt. Wait for the Vdisk or disk group to complete its operation. Do not remove any leftover drives until the rebuild is complete. The status of the Vdisk or disk group that originally had the failed disk is CRIT (Critical) or QTDN (Quarantined with a down disk). If this status occurs after you replace a defective disk with a known good disk, the enclosure midplane might have experienced a failure. Replace the enclosure. 12 Troubleshooting HPE P2000 G3

13 Disk Drive Bay Numbers Figure 3 MSA 2040 SAN Array SFF enclosure Figure 4 MSA 2040 SAN Array LFF or supported drive enclosure Drive Status Table 6 Drive Status Status Available Failed Global spare Leftover Displayed in the CLI or SMU AVAIL FAILED GLOBAL SP LEFTOVR Description The drive is available for use. The drive is unusable and is replaced. Reasons for this status include excessive media errors, SMART errors, drive hardware failures, unsupported drives. The drive is assigned as a global spare. The drive is leftover. It is missing during a rescan of drives or it failed due to Unrecoverable Read Errors (UREs), SMART issues, or other errors. Disk Drives 13

14 Table 6 Drive Status (continued) Status Vdisk or disk group Vdisk or disk group Spare Displayed in the CLI or SMU Vdisk or disk group Vdisk or disk group SP Description The drive is used in a Vdisk or disk group. The drive is a spare assigned to a Vdisk or disk group. Disk Drive Leftover Table 7 Hard disk drive leftover scenarios A disk drive is marked as LEFTOVR. Cause Due to MEDIUM/SMART/PROTOCOL/ I/O TIMEOUT errors. Check if any Vdisks or disk groups are OFFL; if disks are offline, see Using the Trust Command (page 26). If all Vdisks or disk groups are online, consider replacing the disk drive as an option to resolve the issue. Multiple drives all in one enclosure are marked as LEFTOVR. A disk drive in a redundant Vdisk or disk group (in this scenario, other than RAID 6) fails and is marked as LEFTOVR and the Vdisk or disk group status is CRIT. In earlier versions of P2000 G3 firmware, if a Vdisk was spanned across multiple enclosures, and all drives in an enclosure other than the enclosure numbered 1 went missing due to a site issue, a power loss or power supply issue, or loose cabling, the Vdisk may go OFFL. Once the issue is corrected and the disk drives are detected, those disks are marked as LEFTOVR. A spare disk is used and reconstruction begins. Before the reconstruction completes, if another disk drive from the same Vdisk or disk group (same sub-vdisk or subgroup in RAID 10 or RAID 50) fails, the status of the second failed disk drive along with the spare disk is marked as LEFTOVR. The Vdisk or disk group is OFFL or QTOF (quarantined offline). It is not necessary to replace all the disk drives that are marked LEFTOVR, as it is not a disk drive issue. Resolve the site, power or cabling issue. See Using the Trust Command (page 26). Attempt to dequarantine the Vdisk or disk group by reseating the last failed drives. If unable to dequarantine the Vdisk or disk group, see Using the Trust Command (page 26). A disk drive in a RAID 6 Vdisk or disk group (with 1 spare) fails and is marked as LEFTOVR. NOTE: In cases where two/multiple spares are available and a drive fails, the drive is marked as LEFTOVR and the Vdisk or disk group is FTDN. A spare is invoked and reconstruction begins. If another member of the same Vdisk or disk group fails before the reconstruction completes, the spare for the second failed drive is not invoked despite available multiple spares. Once the status of the Vdisk or disk group changes to FTDN, another spare is invoked for this Vdisk or disk group and reconstruction begins. Vdisk or disk group status is FTDN, a spare is invoked, and reconstruction begins. Before the reconstruction completes, if another member of the same Vdisk or disk group fails, its status is marked as LEFTOVR and the Vdisk or disk group status is CRIT. The reconstruction for the first failed drive does not stop but continues to completion. Once the reconstruction completes, the status of the Vdisk or disk group is back to FTDN. Consider replacing the drives if the drives failed due to hardware issues. If the Vdisk or disk group go QTOF after the failure of a third Vdisk or disk group member and before the reconstruction completes, attempt to dequarantine the Vdisk or disk group by reseating the last failed drives. If unable to dequarantine the Vdisk or disk group, consider Using the Trust Command (page 26). 14 Troubleshooting HPE P2000 G3

15 Table 7 Hard disk drive leftover scenarios (continued) Cause Reconstruction stops for a RAID 6 Vdisk when a second drive fails Reconstruction restarts for a RAID 6 Vdisk when a second drive fails. In earlier versions of P2000 G3 firmware, if a RAID 6 Vdisk experiences one drive failure, it would use a spare to reconstruct the Vdisk. But if a second drive fails during the reconstruction and no more spares are available, then the reconstruction stops, the Vdisk status becomes CRIT, and the second failed drive is LEFTOVR. If one more member of the same Vdisk fails and is marked LEFTOVR, the Vdisk goes OFFL. In earlier versions of P2000 G3 firmware, if a RAID 6 Vdisk experiences one drive failure, it would use a spare to reconstruct the Vdisk. If a second drive fails during the reconstruction and a spare is available, then the reconstruction restarts from 0%, and the second failed drive is LEFTOVR. If one more member of the same Vdisk fails and is marked LEFTOVR, the Vdisk goes OFFL. Clear the disk metadata on the drive used for reconstruction. Replace the second failed hard drive if possible, and set both to be spares. Allow the reconstruction to restart. If the vdisk goes OFFL, see Using the Trust Command (page 26). Wait for the Vdisk reconstruction to complete. If the Vdisk goes OFFL, see Using the Trust Command (page 26). Disk Drives 15

16 Vdisk or Disk Group Status Table 8 Vdisk or disk group status Status Critical Fault Tolerant with down drives Fault Tolerant and online Offline Quarantined critical Quarantined offline Quarantined with down drives Up Displayed in the CLI or SMU CRIT FTDN FTOL OFFL QTCR QTOF QTDN UP Description The Vdisk or disk group is online; however, some drives are down and the Vdisk or disk group is not fault tolerant. The Vdisk or disk group is online and fault tolerant; however, some drives are down. The Vdisk or disk group is online and fault tolerant. The Vdisk or disk group is offline because it is using offline initialization or the drives are down and data is lost. The Vdisk or disk group is in a critical state and quarantined because some drives are missing. The Vdisk or disk group is offline and quarantined because some drives are missing. The Vdisk or disk group is offline and quarantined because at least one drive is missing; however, the Vdisk or disk group is accessed and is fault tolerant. Example: One drive is missing from a RAID-6. The Vdisk or disk group is online and does not have fault-tolerant attributes. Vdisk or Disk Group Quarantined If a virtual disk group is quarantined, see Accessing Hewlett Packard Enterprise Support. Do not dequarantine Virtual disk groups without the assistance of knowledgeable support personnel. Table 9 Quarantine during array boot (available in all FW versions) Level Raid 5 Raid 6 During boot, multiple disk drives from the Vdisk or disk group go missing and the Vdisk or disk group status is marked as QTOF. During boot, more than two disk drives go missing from the Vdisk or disk group and the Vdisk or disk group status is marked as QTOF. The system de-quarantines the Vdisk or disk group once the missing disk drives are recognized after a rescan. If the Vdisk or disk group is not de-quarantined, a manual de-quarantine is performed which brings the Vdisk or disk group status to OFFL (if the drives are not recognized during a rescan). If the status of the Vdisk or disk group changes to 16 Troubleshooting HPE P2000 G3

17 Table 9 Quarantine during array boot (available in all FW versions) (continued) Level Raid 10 Raid 50 During boot, both the disk drives from the same sub-vdisk or subgroup go missing and the Vdisk or disk group status is marked as QTOF. One disk drive goes missing from each of the sub-vdisks or subgroups and the Vdisk or disk group status is CRIT. During boot, multiple disk drives from the same sub-vdisk or subgroup go missing and the Vdisk or disk group status is marked as QTOF. One disk drive goes missing from each of the sub-vdisk or subgroups and the Vdisk or disk group status is CRIT. OFFL, follow the troubleshooting steps Using the Trust Command (page 26) for solution. N/A The wrong controller took ownership of the Vdisk or Shutdown the system, remove the controller that took disk group on boot. If controller A owns the Vdisk or ownership of the Vdisk or disk group, insert the other disk group, for example, before booting the controller controller, and boot. If the controller that was the was removed or failed to boot up, the other controller previous owner is not available, then manually owns the Vidisk, controller B. Because the last known dequarantine the Vdisk or disk group. cache and other Vdisk or disk group information is not available on the current controller, the Vdisk or disk group has been quarantined. NOTE: In the previous scenarios, the drives that went down/missing are not spares or reconstruction targets. In the previous scenarios, if the disk drives go missing after a re-scan (firmware T210 and earlier), the Vdisk status is marked as OFFL as there is no Quarantine upon rescan feature available. See Using the Trust Command (page 26). Table 10 Quarantine upon rescan Level Raid 5 Raid 6 Raid 10/50 A disk drive is marked as LEFTOVR or go missing, making the Vdisk or disk group status as CRIT. Another disk drive fails or is missing, the Vdisk or disk group is marked as QTOF. If the disk drives are: Recognized during a rescan, the system will quarantine the Vdisk or disk group for two minutes Not recognized during a rescan, perform a manual de-quarantine to change the Vdisk or disk group status to OFFL. A disk drive is marked as LEFTOVR or go missing making the Vdisk or disk group status as FTDN. Another disk drive from the same Vdisk or disk group If the Vdisk or disk group status changes to OFFL, is marked as LEFTOVR or go missing, the status of see Using the Trust Command (page 26). the Vdisk or disk group is CRIT. One more disk drive from the Vdisk or disk group is marked as LEFTOVR or go missing, the Vdisk or disk group is marked as QTOF. A disk drive is marked as LEFTOVR or go missing, making the Vdisk or disk group status as CRIT. Another disk drive from the same sub-vdisk or subgroup fails or is missing the Vdisk or disk group is marked as QTOF. Disk Drives 17

18 NOTE: In the previous scenarios, if the disk drives fail or go missing or both during a boot and also upon a rescan, the status of the Vdisk or disk group is marked as QTOF. In the previous scenarios, the drives that went down or missing are not spares or reconstruction targets. Disk Drive Failure during Reconstruct A compatible spare has a capacity equal to or greater than the smallest disk in the Vdisk or disk group and is the same disk type (SAS or SATA). Table 11 RAID-6 reconstruction scenarios No compatible spares are available, reconstruction does not start automatically One disk fails and a compatible spare is available Two disks fail and only one compatible spare is available Two disks fail and two compatible spares are available To start reconstruction manually, replace each failed disk, and then do one of the following: Add each new disk as either a dedicated spare or a global spare. Remember that a different critical Vdisk or disk group might take the global spare than the one you intended. When a global spare replaces a disk in a Vdisk or disk group, the global spare s icon in the enclosure view changes to match the other disks in that Vdisk or disk group. Enable the Dynamic Spare Capability option to use the new disks without designating them as spares. The system uses the spare to reconstruct the Vdisk or disk group. If a second disk fails during reconstruction, reconstruction continues until it is complete, regardless of whether a second spare is available. If the spare fails during reconstruction, reconstruction stops. The system waits five minutes for a second spare to become available. After five minutes, the system uses the spare to reconstruct one disk in the Vdisk or disk group (referred to as fail 2, fix 1 mode). If the spare fails during reconstruction, reconstruction stops. The system uses both spares to reconstruct the Vdisk or disk group. If one of the spares fails during reconstruction, reconstruction proceeds in fail 2, fix 1 mode. If the second spare fails during reconstruction, reconstruction stops. Table 12 LEDs - Disk drive LEDs Fault/UID LED illuminates amber Online/Activity LED illuminates green Cause A disk fails. A spare is used as a reconstruction target. NOTE: Depending on the Vdisk or disk group RAID level and size, disk speed, utility priority, and other processes running on the storage system, reconstruction can take hours or days to complete. You can stop reconstruction only by deleting the Vdisk or disk group. 18 Troubleshooting HPE P2000 G3

19 Vdisk or disk group Member Unavailable RAID Level NRAID RAID 0 RAID 1 RAID 5 RAID 10 RAID 50 RAID 6 Vdisk or disk group status is OFFL (Offline). Vdisk or disk group status is OFFL (Offline). Vdisk or disk group status is CRIT (Critical). Vdisk or disk group status is FTDN (Degraded). A single drive failure causes the Vdisk or disk group to go OFFL and Trust cannot recover the data. Data is restored from the backup. If a spare is already available (global or dedicated to the Vdisk or disk group), it is used for the Vdisk or disk group in CRIT or FTDN state and reconstruct begins. Replace the failed disk drive if necessary. If a spare is not available, consider the option to replace the failed disk drive or clear meta-data on LEFTOVR drive and add it as a spare. Two or Multiple Disk Drive Failure RAID Level Description/Notes RAID 1 RAID 5 RAID 6 Two disk drive failures in RAID 1 make it QTOFor OFFL. Failure of two or more disk drives in a RAID 5 Vdisk or disk group makes the Vdisk or disk group QTOFor OFFL. Failure of two disk drives in a RAID 6 Vdisk or disk group makes the Vdisk or disk group CRIT. RAID 1 supports a maximum of two disk drives. NA If multiple spares are available for the Vdisk or disk group, two disk drive reconstruction begins. If the Vdisk goes QTOF, the Vdisk gets de-quarantined automatically after the drives are recognized. If the Vdisk does not get de-quarantined automatically, run a manual de-quarantine to bring the Vdisk to OFFL state; once the Vdisk or disk group is in the OFFL state, see Using the Trust Command (page 26). Failure of multiple disk drives (greater than two) in a RAID 6 Vdisk or disk group makes the Vdisk or disk group QTOFor OFFL. NA RAID 10 Failure of both the disk drives in the same sub-vdisk or subgroup makes the Vdisk or disk group QTOF NA RAID 10, RAID 50 Failure of two or more drives, all in different sub-vdisks or subgroups. In a RAID sub-vdisk or subgroup, if one drive fails, the sub-vdisk or subgroup status, and therefore the Vdisk or disk group status, is CRIT. If two or more sub-vdisks or subgroups have only one drive failed, the status of the Vdisk or disk group is still CRIT. Available spares will be used for reconstruction. Disk Drives 19

20 Vdisk or Disk Group Alerts Vdisk or disk group is critical For RAID types other than RAID 6, see Vdisk or disk group Member Unavailable (page 19) and Two or Multiple Disk Drive Failure (page 19) For RAID 6, see Two or Multiple Disk Drive Failure (page 19) Vdisk or disk group is quarantined Vdisk or disk group is offline Vdisk or disk group reconstruction failed See Vdisk or Disk Group Quarantined (page 16). See Using the Trust Command (page 26). See Disk Drive Failure during Reconstruct (page 18). Vdisk or disk group Expansion Frequently Asked Questions (FAQs) Question During a Vdisk or disk group expansion, multiple disk drives go missing or are failed while the Vdisk or disk group is quarantined. Will the expansion continue once the disk drives return and the Vdisk or disk group de-quarantines? During the expansion of a Vdisk or disk group (other than RAID 6), if a drive fails making the Vdisk or disk group CRIT and a spare is available can a reconstruction happen? During RAID 6 Vdisk or disk group expansion if two drives fail, can it do two drive reconstruction? Is it possible to create a backup of a Vdisk or disk group while an expansion is underway? During a Vdisk or disk group expansion, if the Vdisk or disk group go OFFL, can we use TRUST to bring the Vdisk or disk group online? If so will the expansion then proceed? Answer Yes, expansion resumes once the Vdisk or disk group is automatically de-quarantined. NOTE: Avoid using the manual de-quarantine option as it takes the Vdisk or disk group OFFL, which causes data loss. No, the spare is not used and the reconstruction does not begin immediately after the drive fails. Reconstruction begins only after the completion of the expansion. A backup is recommended in case there is further drive failures. Two drive reconstructions are performed after the expansion completes. A backup is recommended in case there is further drive failures. Yes, backup of a Vdisk or disk group is performed during Vdisk or disk group expansion. NOTE: Best practice is to perform a backup of the data before initiating the expansion of a Vdisk or disk group. Trust cannot be performed if a Vdisk or disk group go OFFL during Vdisk or disk group expansion. Expansion is aborted and any data on the Vdisk or disk group is irrevocably lost. During a Vdisk or disk group expansion, if the controller owning the Vdisk or disk group crashes, will the expansion continue after the Vdisk or disk group is failed over to the partner controller? Yes, Vdisk or disk group expansion continues after the Vdisk or disk group is failed over to the partner controller. Can we create a secondary volume and create snapshots of a volume that is a member of a Vdisk or disk group under expansion? What about other activities like replication? Can the volumes of an expanding Vdisk or disk group be remapped to different hosts? We can create a secondary volume and snapshots are created for a Vdisk or disk group under expansion. All the other activities work fine. Yes, the volumes can be remapped. For information on replacing the drive modules, see HPE MSA2000/P2000 Drive Module Replacement Instructions Guide on the Hewlett Packard Enterprise Support Center website. 20 Troubleshooting HPE P2000 G3

21 nl nl Management Controller Issue Restarting the Management Controller (page 21) Instances when the Management Controller becomes Unresponsive (page 22) Restarting the Management Controller The Management Controller (MC) is the array component that is responsible for functions related to the management of the array. The Storage Controller (SC) is responsible for handling Host IO to the array. Both the MC and SC reside within the same physical controller module. Some Management Controller functions are: Managing array user accounts Managing array logins Managing array configuration information Table 13 Management Controller scenarios SC component is functioning properly and all Host I/O are being handled correctly while the MC component is not accepting a user login A storage controller might be replaced or power-cycled due to an unresponsive Management Controller port. Restart MC from the other controller, if possible. If that does not resolve the issue, restart the array. Log in to the Management Controller on the other storage controller and restart the unresponsive Management Controller. For example, an array with the following setup: Controller A IP Controller B IP Verify the network connectivity by issuing a ping to the MC IP address of the controller. Ensure that an issue does not exist with the intranet on which the MSA is installed. # ping Reply from bytes=32 time60 If the ping command does not return a valid response, investigate the network or cabling. If controller A responds to the ping but is not enabling logins via the CLI or SMU interface, log in to controller B via the CLI and attempt to restart the MC on controller A. The following example shows a login and restart of a controller through the CLI interface: #restart mc A Continue? yes <enter return> Success: MC A restarted. There may be up to a minute delay between the Continue prompt and hitting the Yes <enter return> to when the Success information is displayed. Wait a few moments after the Success information is displayed for the restart process to complete and then try to log in to controller A. If the Management Controller remains unresponsive, shutdown and restart controller A using the opposite controller B, then recheck the Management Controller. NOTE: During restart, you will briefly lose communication with the specified management controllers: From controller B: #shutdown A Wait for A to shutdown Management Controller Issue 21

22 Table 13 Management Controller scenarios (continued) #restart sc a < this will restart the Management Controller on controller A as well >. NOTE: In a single controller environment, if the CLI command is not successful, quiesce all host I/Os before restarting the SC of the controller. Instances when the Management Controller becomes Unresponsive Table 14 Instances when the Management Controller becomes Unresponsive Cause The following messages regularly appear in the array logs: 237 INFORMATIONAL Firmware update progress: The firmware was verified. (from MC: yes, for MC: no) (p1: 1, p2: 1, p3: 0, p4: 0) 237 INFORMATIONAL Firmware update progress: The SC loader was updated. Saved in primary location in flash. The firmware is the same so it was not flashed. (p1: 2, p2: 1, p3: 0, p4: 0) 237 INFORMATIONAL Firmware update progress: The SC app was updated. Saved in primary location in flash. The firmware is different so it was flashed; flashed successfully. (p1: 4, p2: 1, p3: 1, p4: 0) Firmware Flash is blocked, upgrade retries are evident. For systems that are in a firmware upgrade loop: 1. Backup and verify all data on the system. 2. Run the Online ROM Flash Component again to upgrade both the controllers. 3. Use the FTP option to upgrade both controllers: ftp> put firmware_file flash 4. Allow firmware upgrade to complete fully. 5. Use either SMU or the CLI, check, and confirm all firmware versions for the Management Controller and Storage Controller matches between both controllers 237 INFORMATIONAL Firmware update progress: The memory-controller FPGA was updated. Saved in primary location in flash. The firmware is the same so it was not flashed. (p1: 3, p2: 1, p3: 0, p4: 0) 22 Troubleshooting HPE P2000 G3

23 Table 14 Instances when the Management Controller becomes Unresponsive (continued) Cause The following sequence of messages appears in the array logs: Management Controller and Storage Controller are unable to communicate. For systems that have a communication error between the MC and SC, perform any one of the following steps: 152 INFORMATIONAL The Storage Controller is not receiving data from the Management Run the following CLI command: Controller. (This is normal during firmware update.) 153 INFORMATIONAL The Storage Controller resumed communications with the Management Controller. 152 INFORMATIONAL The Storage Controller is not receiving data from the Management Controller. 156 WARNING The Management Controller was restarted by the Storage Controller. 139 INFORMATIONAL The Management Controller booted up. MC firmware version: XXXXXXXX (baselevel: XXXX) 153 INFORMATIONAL The Storage Controller resumed communications with the Management Controller. 152 INFORMATIONAL The Storage Controller is not receiving data from the Management Controller. (This is normal during firmware update.) 153 INFORMATIONAL The Storage Controller resumed communications with the Management Controller #restart mc A Continue? yes <enter return> Success: MC A restarted. Restart the MC using SMU. NOTE: During the restart process, you will briefly lose communication with the specified management controllers In some cases, if the restart function previously noted does not clear the MC hang issue, you might attempt to reseat the offending controller. Before reseating the offending controller, you must perform a couple of safety measures: 1. Get and verify a backup of the data on the array. 2. If possible, quiesce the I/O to the array. 3. Shutdown the controller, for example, shutdown a b both Alternatively, shutdown the controller using the SMU. Shutting down both the controllers is an offline activity. 4. Reseating a controller with active I/O in a dual controller array will cause I/O failover to the other controller. In a single controller array, this reseating should be scheduled during a maintenance window. The configuration information is lost, array management, event messaging, and logging cease to function, but the host I/O continues to operate normally In both single and dual controller environments, when the MC fails, the result may be a loss of the controller configuration information on the affected controller. The array cannot be managed from the impacted controller, but through the partner controller if available. The configuration information is stored in a non-volatile memory. Resetting or powering off the controller will not resolve the error. The controller must be replaced to resolve this error. 1. Log on to SMU or CLI/telnet. Single Controller Environment If successful, the MC will be up, and you can proceed with the firmware upgrade. Dual Controller Environments If successful, the MC will be up. Check the MC on the other controller to confirm it is accessible. a. Halt all host I/O before upgrading the controller. b. The firmware upgrade can be performed using either FTP or SMU. Management Controller Issue 23

24 Table 14 Instances when the Management Controller becomes Unresponsive (continued) Cause If unsuccessful, the MC is suffering from the firmware issue. a. Single Controller Environment Halt all Host I/O and power cycle the array. If access is restored, proceed with the firmware upgrade. Dual Controller Environments Halt all Host I/O and power cycle the array. If access is restored, verify that MC on the second controller is accessible or operational. b. If access is not restored, replace the controller and confirm that the new controller is at a new code version or upgrade if necessary. 2. Once the firmware upgrade is complete, verify the MC code version has upgraded correctly. 3. If you cannot log onto SMU or telnet after the firmware upgrade, you will need to replace the controller. For information on replacing the Controller Module, see HPE MSA Controller Module Replacement Instructions Guide on the Hewlett Packard Enterprise Support Center website. Power Supply Faults and Power Cycle Power Cycle Power Cycle (page 24) Power Supply Faults and Recommended Actions (page 25) Under normal operations because of the redundant nature of the MSA array, the system should not require a full system power cycle. Restarting each controller independently results in the same outcome as a full power cycle, while still maintaining host connectivity. On the front of every MSA is an Enclosure ID LED. This LED will aid in identifying the Controller shelf. The Controller Shelf will report as "1" and any subsequent enclosures will have higher numbered IDs. If a power cycle is needed, follow these steps: 1. Shut down, dismount, or unmap the hosts (servers) with access to the MSA volumes. This allows any pending writes in Application cache or Server memory to flush to the MSA controllers write-back cache. 2. Shut down both array controllers in a dual controller system or a single controller system by using SMU or CLI interface. This allows the controllers to flush the controller write cache to the disks. 24 Troubleshooting HPE P2000 G3

25 NOTE: Never remove the power cords from the Power Supplies on the RAID enclosure without properly shutting down the array controllers first. Shutting down the controllers allows for any write cache in the controller modules to be properly flushed down to the Hard Drives. Removing power from single JBODs may adversely affect Vdisk or disk groups that are shared between enclosures. 3. JBOD Enclosures only need to be powered off for routine maintenance. The JBODs must be powered off only after the controllers are properly shut down using the CLI or SMU. To power off the JBOD enclosures either remove the power cables or turn off the switch, whichever step is applicable for your power supplies. Perform the reverse steps when restoring power to the Storage infrastructure. Power on the JBOD enclosures from the bottom to the top, allowing for the drives in each JBOD to power up before powering the next JBOD enclosure. If the enclosures are powered off, wait a minimum of one minute after powering on the last JBOD enclosure before powering up the MSA controllers. This allows the Hard Drives enough time to spin up before the array controllers come online. CAUTION: Never power cycle an array without knowing the status of the controllers. Removing power from a controller processing host IO could have negative consequences to data integrity. NOTE: Power on the JBOD enclosures from the bottom enclosure to the top, allowing enough time for the drives to spin up. The 6TB and 8TB drives take time. Power Supply Faults and Recommended Actions Table 15 Power supply faults and recommended actions Power supply warning or failure. Related Event code 551. Power supply module status is listed as failed or you receive a voltage event notification. Related Event code 551. Recommended Action Verify the following: All the power supply units are working. No slots are left open for more than two minutes. If you might need to replace a module, leave the old module in place until you have the replacement, or use a blank cover to close the slot. Leaving a slot open negatively affects the airflow and might cause the unit to overhead. The controller modules are properly seated in their slots and that their latches are locked. If the power supply module has a switch, ensure that the switch is turned on. Ensure that the power cables are firmly plugged into both power supply and into an appropriate functional electrical outlet. Replace the power supply module. Power LED is off. If the power supply module has a switch, ensure that the switch is turned on. Ensure that the power cables are firmly plugged into both power supply and into an appropriate electrical outlet. Replace the power supply module. Voltage/Fan Fault/Service Required LED is on. Replace the power supply module. Power Supply Faults and Power Cycle 25

HPE MSA Storage Troubleshooting Guide

HPE MSA Storage Troubleshooting Guide HPE MSA Storage Troubleshooting Guide Abstract This document provides information about troubleshooting HPE MSA Storage Systems. Use this document to troubleshoot and maintain Hewlett Packard Enterprise

More information

MSA Event Descriptions Reference Guide

MSA Event Descriptions Reference Guide MSA Event Descriptions Reference Guide Abstract This guide is for reference by storage administrators to help troubleshoot storage-system issues. It describes event messages that may be reported during

More information

HP P2000 G3 MSA System Event Descriptions Reference Guide

HP P2000 G3 MSA System Event Descriptions Reference Guide HP P2000 G3 MSA System Event Descriptions Reference Guide Part number: 591224-006 First edition: February 2013 Legal and notice information Copyright 2013 Hewlett-Packard Development Company, L.P. Confidential

More information

AssuredSAN Event Descriptions Reference Guide

AssuredSAN Event Descriptions Reference Guide AssuredSAN Event Descriptions Reference Guide Abstract This guide is for reference by storage administrators to help troubleshoot storage-system issues. It describes event messages that may be reported

More information

AssuredSAN Pro 5000 Series Events Reference Guide

AssuredSAN Pro 5000 Series Events Reference Guide AssuredSAN Pro 5000 Series Events Reference Guide P/N 83-00005246-10-01 Revision A January 2013 Copyright 2012 Dot Hill Systems Corp. All rights reserved. Dot Hill Systems Corp., Dot Hill, the Dot Hill

More information

HP StorageWorks P2000 G3 MSA System Event Descriptions Reference Guide

HP StorageWorks P2000 G3 MSA System Event Descriptions Reference Guide HP StorageWorks P2000 G3 MSA System Event Descriptions Reference Guide Part number: 591224-003 First edition: September 2010 Legal and notice information Copyright 2010 Hewlett-Packard Development Company,

More information

HPE ProLiant Gen9 Troubleshooting Guide

HPE ProLiant Gen9 Troubleshooting Guide HPE ProLiant Gen9 Troubleshooting Guide Volume II: Error Messages Abstract This guide provides a list of error messages associated with HPE ProLiant servers, Integrated Lights-Out, Smart Array storage,

More information

Dell EMC ME4 Series Storage Systems. Release Notes

Dell EMC ME4 Series Storage Systems. Release Notes Dell EMC ME4 Series Storage Systems Release Notes Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

HP StorageWorks 2012sa Modular Smart Array user guide

HP StorageWorks 2012sa Modular Smart Array user guide HP StorageWorks 2012sa Modular Smart Array user guide Part number: 488320-002 Second edition: July 2008 Legal and notice information Copyright 2008 Hewlett-Packard Development Company, L.P. Hewlett-Packard

More information

Hardware Owner s Manual

Hardware Owner s Manual Dell PowerVault MD3000 RAID Enclosure Hardware Owner s Manual www.dell.com support.dell.com Notes, Notices, and Cautions NOTE: A NOTE indicates important information that helps you make better use of your

More information

Dell PowerVault MD3200 and MD3220 Storage Arrays. Owner s Manual. Regulatory Model: E03J Series and E04J Series Regulatory Type: E03J001 and E04J001

Dell PowerVault MD3200 and MD3220 Storage Arrays. Owner s Manual. Regulatory Model: E03J Series and E04J Series Regulatory Type: E03J001 and E04J001 Dell PowerVault MD3200 and MD3220 Storage Arrays Owner s Manual Regulatory Model: E03J Series and E04J Series Regulatory Type: E03J001 and E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important

More information

Troubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER

Troubleshooting. Resetting the System. Problems Following Initial System Installation. First Steps Checklist CHAPTER CHAPTER 6 This chapter helps you identify and solve problems that might occur while you are using the Cisco CDE110. If you are unable to resolve your server problems on your own, contact Cisco Technical

More information

Slide 0 Welcome to the Support and Maintenance chapter of the ETERNUS DX90 S2 web based training.

Slide 0 Welcome to the Support and Maintenance chapter of the ETERNUS DX90 S2 web based training. Slide 0 Welcome to the Support and Maintenance chapter of the ETERNUS DX90 S2 web based training. 1 This module introduces support and maintenance related operations and procedures for the ETERNUS DX60

More information

Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual

Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual Regulatory Model: E03J and E04J Series Regulatory Type: E03J001 and E04J001 Notes, cautions, and warnings NOTE: A NOTE indicates important

More information

HP StorageWorks 2012i Modular Smart Array user guide

HP StorageWorks 2012i Modular Smart Array user guide HP StorageWorks 2012i Modular Smart Array user guide Part number: 481598-001 First edition: March, 2008 Legal and notice information Copyright 2008 Hewlett-Packard Development Company, L.P. Hewlett-Packard

More information

HP 2012fc Modular Smart Array user guide

HP 2012fc Modular Smart Array user guide HP 2012fc Modular Smart Array user guide Part number: 481597-002 First edition: January, 2013 Legal and notice information Copyright 2008, 2013 Hewlett-Packard Development Company, L.P. Hewlett-Packard

More information

HPE StoreEasy 1000 Storage Administrator Guide

HPE StoreEasy 1000 Storage Administrator Guide HPE StoreEasy 1000 Storage Administrator Guide Abstract This document describes how to install, configure, and maintain all models of HPE StoreEasy 1000 Storage running WSS2012 R2 and WSS2016 and is intended

More information

Dell EMC PowerVault MD3460 Storage Arrays

Dell EMC PowerVault MD3460 Storage Arrays Dell EMC PowerVault MD3460 Storage Arrays Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you

More information

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that

More information

Dell EMC ME4 Series JBOD 5U84 Enclosure

Dell EMC ME4 Series JBOD 5U84 Enclosure Dell EMC ME4 Series JBOD 5U84 Enclosure Deployment Guide Regulatory Model: E09J, E10J, E11J Regulatory Type: E09J001, E10J001, E11J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information

More information

Notice for Express Report Service (MG)

Notice for Express Report Service (MG) NEC Express5800, ilo Embedded Server Notice for Express Report Service (MG) Revision 1.0 Nov 22, 2017 NEC Corporation Table of Contents Table of Contents... 2 Trademarks... 3 Cautions... 3 Reference Sites...

More information

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview Overview The HP Smart Array P800 is HP's first 16 port serial attached SCSI (SAS) RAID controller with PCI-Express (PCIe). It is the highest performing controller in the SAS portfolio and provides new

More information

Dell PowerVault MD3600f and MD3620f Storage Arrays. Owner s Manual. Regulatory Model: E03J Series and E04J Series Regulatory Type: E03J001 and E04J001

Dell PowerVault MD3600f and MD3620f Storage Arrays. Owner s Manual. Regulatory Model: E03J Series and E04J Series Regulatory Type: E03J001 and E04J001 Dell PowerVault MD3600f and MD3620f Storage Arrays Owner s Manual Regulatory Model: E03J Series and E04J Series Regulatory Type: E03J001 and E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates

More information

Dell EMC Unity Family

Dell EMC Unity Family Dell EMC Unity Family SNMP Alert Messages Reference Guide Version 4.3 Abstract This document includes information about the SNMP alert messages that can appear for the Unity platform and UnityVSA. P/N

More information

Configuration Tool and Utilities v3.25 Operation Manual. for Fusion RAID Storage Systems

Configuration Tool and Utilities v3.25 Operation Manual. for Fusion RAID Storage Systems Configuration Tool and Utilities v3.25 Operation Manual for Fusion RAID Storage Systems Contents 1.0 ATTO Configuration Tool Overview... 1 About the Configuration Tool Configuration Tool Launch Configuration

More information

Dell PowerEdge RAID Controller (PERC) S130 User s Guide

Dell PowerEdge RAID Controller (PERC) S130 User s Guide Dell PowerEdge RAID Controller (PERC) S130 User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide. support.dell.com

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide.   support.dell.com Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5 User s Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better

More information

Troubleshooting the System Hardware

Troubleshooting the System Hardware CHAPTER 5 This chapter provides basic troubleshooting information to help you identify some common problems that might occur with your Wide Area Virtualization Engine (WAVE). This chapter contains the

More information

HP D2600/D2700 Disk Enclosure I/O Module Firmware 0147 Release Notes

HP D2600/D2700 Disk Enclosure I/O Module Firmware 0147 Release Notes HP D2600/D2700 Disk Enclosure I/O Module Firmware 0147 Release Notes HP Part Number: 504224-008 Published: October 2012 Edition: 8 Copyright 2009, 2012 Hewlett-Packard Development Company, L.P. nl Version:

More information

Dell PowerVault MD3200i and MD3220i Storage Arrays. Owner s Manual. Regulatory Model: E03J Series and E04J Series Regulatory Type: E03J001 and E04J001

Dell PowerVault MD3200i and MD3220i Storage Arrays. Owner s Manual. Regulatory Model: E03J Series and E04J Series Regulatory Type: E03J001 and E04J001 Dell PowerVault MD3200i and MD3220i Storage Arrays Owner s Manual Regulatory Model: E03J Series and E04J Series Regulatory Type: E03J001 and E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates

More information

QuickSpecs. Models. Overview

QuickSpecs. Models. Overview Overview The HP Smart Array P400 is HP's first PCI-Express (PCIe) serial attached SCSI (SAS) RAID controller and provides new levels of performance and reliability for HP servers, through its support of

More information

2002 Series FRU Installation and Replacement Guide

2002 Series FRU Installation and Replacement Guide 2002 Series FRU Installation and Replacement Guide P/N 83-00004523-11 Revision C August 2009 Copyright Protected Material 2009. All rights reserved. R/Evolution and the R/Evolution logo are trademarks

More information

Configuring and Using Redundant Disks with Cisco MCS

Configuring and Using Redundant Disks with Cisco MCS Configuring and Using Redundant Disks with Cisco MCS Document ID: 9229 Contents Introduction Prerequisites Requirements Components Used Conventions Drive Mirroring (RAID 1) Recognize a Drive Failure Recover

More information

HPE D2600/D2700 Disk Enclosure I/O Module Firmware 0149 Release Notes

HPE D2600/D2700 Disk Enclosure I/O Module Firmware 0149 Release Notes HPE D2600/D2700 Disk Enclosure I/O Module Firmware 0149 Release Notes Part Number: 504224-011R Published: November 2015 Edition: 12 Copyright 2009, 2015 Hewlett Packard Enterprise Development LP The information

More information

High Availability and MetroCluster Configuration Guide For 7-Mode

High Availability and MetroCluster Configuration Guide For 7-Mode Updated for 8.2.1 Data ONTAP 8.2 High Availability and MetroCluster Configuration Guide For 7-Mode NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501

More information

Dell Storage MD1400 Enclosures Hardware Owner's Manual

Dell Storage MD1400 Enclosures Hardware Owner's Manual Dell Storage MD1400 Enclosures Hardware Owner's Manual Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

SAS JBOD Installation Reference Guide Revision 1.0

SAS JBOD Installation Reference Guide Revision 1.0 SAS JBOD 16-bay Rackmount Enclosure Installation Reference Guide Revision 1.0 P/N: PW0020000000281 Copyright No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 6 Supporting Hard Drives

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 6 Supporting Hard Drives A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e Chapter 6 Supporting Hard Drives Objectives Learn about the technologies used inside a hard drive and how data is organized on the drive

More information

Intelligent Drive Recovery (IDR): helping prevent media errors and disk failures with smart media scan

Intelligent Drive Recovery (IDR): helping prevent media errors and disk failures with smart media scan Intelligent Drive Recovery (IDR): helping prevent media errors and disk failures with smart media scan White paper Version: 1.1 Updated: Sep., 2017 Abstract: This white paper introduces Infortrend Intelligent

More information

XL-RAID-213SA User Manual

XL-RAID-213SA User Manual XL-RAID-213SA User Manual Introduction English Thank you for purchasing our products. This manual will introduce the XL-RAID-213SA Series. Before using your XL-RAID-213SA, please read this manual thoroughly.

More information

HP Scalable File Share G3 MSA2000fc How To

HP Scalable File Share G3 MSA2000fc How To HP Scalable File Share G3 MSA2000fc How To Abstract This document provides best practices for critical or sensitive MSA2000fc storage operations and configuration information specifically for the HP SFS

More information

Using GIGABYTE Notebook for the First Time

Using GIGABYTE Notebook for the First Time Congratulations on your purchase of the GIGABYTE Notebook P7! This Manual will help you to get started with setting up your notebook. For more detailed information, please visit our website at http://www.gigabyte.com.

More information

RAID EzAssist Configuration Utility User Reference Guide

RAID EzAssist Configuration Utility User Reference Guide RAID EzAssist Configuration Utility User Reference Guide DB13-000047-00 First Edition 08P5519 Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation. The information

More information

10 Having Hot Spare disks available in the system is strongly recommended. There are two types of Hot Spare disks:

10 Having Hot Spare disks available in the system is strongly recommended. There are two types of Hot Spare disks: 0 This Web Based Training module provides support and maintenance related information for the ETERNUS DX S2 family. This module provides an introduction to a number of ETERNUS Web GUI functions, for a

More information

Intelligent Drive Recovery (IDR): helping prevent media errors and disk failures with smart media scan

Intelligent Drive Recovery (IDR): helping prevent media errors and disk failures with smart media scan Intelligent Drive Recovery (IDR): helping prevent media errors and disk failures with smart media scan White paper Version: 1.1 Updated: Oct., 2017 Abstract: This white paper introduces Infortrend Intelligent

More information

Upgrading R/Evolution Storage Systems

Upgrading R/Evolution Storage Systems Upgrading R/Evolution Storage Systems This guide describes considerations and procedures for upgrading the following R/Evolution storage systems: 2000 Series to 2002 Series storage systems 2000 Series

More information

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.inxtron.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...

More information

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21

Models Smart Array 6402/128 Controller B21 Smart Array 6404/256 Controller B21 Overview The Smart Array 6400 high performance Ultra320, PCI-X controller family provides maximum performance, flexibility, and reliable data protection for HP ProLiant servers, through its unique modular

More information

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2 Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives User Manual July 27, 2009 - v1.2 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III

More information

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide

Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter. User s Guide Dell PowerEdge 6 Gbps SAS HBA and Internal Tape Adapter User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION:

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

Dell PowerEdge RAID Controller S140 - PERC S140. User s Guide

Dell PowerEdge RAID Controller S140 - PERC S140. User s Guide Dell PowerEdge RAID Controller S140 - PERC S140 User s Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2 SAS to SAS/SATA JBOD Subsystem Revision 1.2 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Subsystem... 6 1.4 Identifying Parts

More information

Troubleshooting Initial Startup Problems

Troubleshooting Initial Startup Problems Your Cisco ASR 1000 Series Router went through extensive testing before leaving the factory. However, if you encounter problems starting the router, use the information in this chapter to help isolate

More information

E-Series Maintaining E2800 Hardware

E-Series Maintaining E2800 Hardware E-Series Maintaining E2800 Hardware September 2018 215-13051_A0 doccomments@netapp.com Table of Contents 3 Contents Batteries... 6 Overview and requirements... 6 Battery overview... 6 Requirements for

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

QuickSpecs. Models. HP Smart Array P400i Controller. Overview

QuickSpecs. Models. HP Smart Array P400i Controller. Overview Overview The HP Smart Array P400 Serial Attached SCSI (SAS) controller (SA-P400) provides new levels of performance and reliability for HP servers, through its support of the latest SCSI technology and

More information

PowerVault MD3 Storage Array Enterprise % Availability

PowerVault MD3 Storage Array Enterprise % Availability PowerVault MD3 Storage Array Enterprise 99.999% Availability Dell Engineering June 2015 A Dell Technical White Paper THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS

More information

T E C H N O L O G I E S. User Guide. 1:1 HDD Duplicator PRO (HDUSI325)

T E C H N O L O G I E S. User Guide. 1:1 HDD Duplicator PRO (HDUSI325) T E C H N O L O G I E S Duplicator Panel Power Switch Source Drive Bay Target Drive Bay User Guide 1:1 HDD Duplicator PRO (HDUSI325) www.addonics.com v3.1.11 Technical Support If you need any assistance

More information

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0 4-Bay Rack Mount Chassis User Manual February 6, 2009 - v1.0 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM esata equipped

More information

HPE Smart Array P431 Controller User Guide

HPE Smart Array P431 Controller User Guide HPE Smart Array P431 Controller User Guide Abstract This document includes feature, installation, and configuration information about HPE Smart Array Controllers and is for the person who installs, administers,

More information

HP D6000 Disk Enclosure User Guide

HP D6000 Disk Enclosure User Guide HP D6000 Disk Enclosure User Guide Abstract This guide describes identification, operations, setup, configuration and utilities, troubleshooting, regulatory notices, specifications, and technical support.

More information

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003 Dell PowerEdge FD332 Owner's Manual Regulatory Model: E02B Regulatory Type: E02B003 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Product Release Notes

Product Release Notes Product Release Notes ATTO Configuration Tool v3.38 - Windows 1. General Release Information The ATTO Configuration Tool helps you customize the settings of your ATTO storage Controller to maximize the

More information

Dell SC5020 and SC5020F Storage System Owner s Manual

Dell SC5020 and SC5020F Storage System Owner s Manual Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here

HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here HPE LTO Ultrium 30750,15000, 6250, 3000, 1760, and 920 Internal Tape Drives Start Here Abstract This document describes how to install a StoreEver LTO Ultrium SAS internal tape drive and is intended for

More information

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak Version 5b Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak This document describes the procedures for protecting data and restoring array status to arrays that have gone OFFLINE. Promise

More information

NEC Express5800 Series. StorView Ver. 3. Operation Guide. for N F B

NEC Express5800 Series. StorView Ver. 3. Operation Guide. for N F B NEC Express5800 Series StorView Ver. 3 Operation Guide for N8190-121F Trademarks NEC ESMPRO is the registered trademark of NEC Corporation. Microsoft, Windows are registered trademarks or trademarks of

More information

Dell PowerEdge RAID Controller (PERC) S130 User s Guide

Dell PowerEdge RAID Controller (PERC) S130 User s Guide Dell PowerEdge RAID Controller (PERC) S130 User s Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

HPE ProLiant MicroServer Gen10 Troubleshooting Guide

HPE ProLiant MicroServer Gen10 Troubleshooting Guide HPE ProLiant MicroServer Gen10 Troubleshooting Guide Abstract This document describes common procedures and solutions for troubleshooting the HPE ProLiant MicroServer Gen10. This document is intended for

More information

SSD7110 Hybrid Connectivity M.2 + SAS/SATA Ports, All-in one RAID Controller. User Guide V1.01

SSD7110 Hybrid Connectivity M.2 + SAS/SATA Ports, All-in one RAID Controller. User Guide V1.01 SSD7110 Hybrid Connectivity M.2 + SAS/SATA Ports, All-in one RAID Controller User Guide V1.01 1 Table of Contents System Requirements... 3 SSD7101A Hardware... 3 NVMe Drive Installation:... 4 Setting up

More information

ETERNUS DX60 and DX80

ETERNUS DX60 and DX80 Highlights Low environmental impact Highly scalable & versatile connectivity User friendly management systems Outstanding reliability 1 Overview (1) are designed to meet the needs of all environments from

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0 SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Terminologies... 6 Chapter 2 Getting Started... 7 2.1 Unpacking

More information

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0 64 Bays SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Preface... 4 Before You Begin... 5 Safety Guidelines... 5 Controller Configurations... 5 Packaging, Shipment and Delivery... 5 Unpacking

More information

HPE MSA 2050 and MSA 2052 Storage VL100P001 Firmware Release Notes

HPE MSA 2050 and MSA 2052 Storage VL100P001 Firmware Release Notes HPE MSA 2050 and MSA 2052 Storage VL100P001 Firmware Release Notes Abstract This package delivers firmware for the HPE MSA 2050 and MSA 2052 Storage systems. Part Number: Q1J79-62019 Published: August

More information

InTANK Series ir2620-2s-s2 / SR2611-2S-S2R User Manual

InTANK Series ir2620-2s-s2 / SR2611-2S-S2R User Manual InTANK Series ir2620-2s-s2 / SR26-2S-S2R User Manual ir2620-2s-s2 SR26-2S-S2R v.2.2 (Jun, 20) Index Chapter Check Package Contents and Accessories... Chapter 2 Hardware Introduction... Chapter Precaution

More information

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu.

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. 1 This training module is divided in six main chapters.

More information

Quick Setup & Getting Started Business PCs

Quick Setup & Getting Started Business PCs Quick Setup & Getting Started Business PCs Copyright 2008 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and Windows

More information

SOHOTANK ST4-TB User Manual

SOHOTANK ST4-TB User Manual SOHOTANK ST4-TB User Manual Introduction SOHOTANK ST4-TB User Manual Thank you for purchasing STARDOM products. This manual will introduce the ST4 Series. Before using your ST4, please read this manual

More information

Chassis (FRU) Replacement Guide

Chassis (FRU) Replacement Guide SIEM9750 Release 1.0 Chassis (FRU) Replacement Guide Issue: 02 Date: 2011-11-07 Page 1 of 26 This document is intended for Symantec support personnel, IBM, or other authorized Symantec Service Partners.

More information

Installing the IBM ServeRAID Cluster Solution

Installing the IBM ServeRAID Cluster Solution Installing the IBM ServeRAID Cluster Solution For IBM Netfinity ServeRAID-4x Ultra160 SCSI Controllers Copyright IBM Corp. 2000 1 2 IBM Netfinity Installing the IBM ServeRAID Cluster Solution Chapter 1.

More information

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell PowerVault MD3060e Storage Enclosure Owner's Manual Dell PowerVault MD3060e Storage Enclosure Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you

More information

Troubleshooting. User Guide

Troubleshooting. User Guide Troubleshooting User Guide Copyright 2006 Hewlett-Packard Development Company, L.P. Microsoft and Windows are U.S. registered trademarks of Microsoft Corporation. The information contained herein is subject

More information

Troubleshooting CHAPTER

Troubleshooting CHAPTER CHAPTER 5 If your system has problems during start up or operation, use the information in this chapter to help isolate the cause. Problems with the initial startup are often caused by a switching module

More information

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual.

Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Integrated Mirroring SAS User s Guide Areas Covered Before Reading This Manual Chapter 1 Chapter 2 Chapter 3 This section explains the notes for your safety and conventions used in this manual. Overview

More information

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired

QuickSpecs. Models. HP Smart Array 642 Controller. Overview. Retired Overview The Smart Array 642 Controller (SA-642) is a 64-bit, 133-MHz PCI-X, dual channel, SCSI array controller for entry-level hardwarebased fault tolerance. Utilizing both SCSI channels of the SA-642

More information

RocketU 1144CM Host Controller

RocketU 1144CM Host Controller RocketU 1144CM Host Controller 4-Port USB 3.0 PCI-Express 2.0 x4 RAID HBA for Mac User s Guide Revision: 1.0 Dec. 13, 2012 HighPoint Technologies, Inc. 1 Copyright Copyright 2013 HighPoint Technologies,

More information

Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide

Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide Dell EMC BOSS-S1 (Boot Optimized Server Storage) User's Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION

More information

HP Supporting the HP ProLiant Storage Server Product Family.

HP Supporting the HP ProLiant Storage Server Product Family. HP HP0-698 Supporting the HP ProLiant Storage Server Product Family https://killexams.com/pass4sure/exam-detail/hp0-698 QUESTION: 1 What does Volume Shadow Copy provide?. A. backup to disks B. LUN duplication

More information

SCv3000 and SCv3020 Storage System. Owner s Manual

SCv3000 and SCv3020 Storage System. Owner s Manual SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

SAS to SAS/SATA RAID Subsystem

SAS to SAS/SATA RAID Subsystem SAS to SAS/SATA RAID Subsystem Revision 1.0 Table of Contents Preface... 5 Before You Begin... 6 Safety Guidelines... 6 Controller Configurations... 6 Packaging, Shipment and Delivery... 6 Unpacking the

More information

SAS to SAS/SATA RAID Subsystem

SAS to SAS/SATA RAID Subsystem SAS to SAS/SATA RAID Subsystem Revision 1.0 Table of Contents Preface... 5 Before You Begin... 6 Safety Guidelines... 6 Controller Configurations... 6 Packaging, Shipment and Delivery... 6 Unpacking the

More information

T E C H N O L O G I E S ENT ESC. User Guide. 1:5 HDD Duplicator Deluxe (HDUS5325DX)

T E C H N O L O G I E S ENT ESC. User Guide. 1:5 HDD Duplicator Deluxe (HDUS5325DX) T E C H N O L O G I E S ENT ESC Duplicator Panel Source Drive Target Drives Power Switch User Guide 1:5 HDD Duplicator Deluxe (HDUS5325DX) www.addonics.com v3.1.11 Technical Support If you need any assistance

More information

MNAS-4100 User s Guide. Preliminary draft only

MNAS-4100 User s Guide. Preliminary draft only MNAS-4100 User s Guide Preliminary draft only April 2006 TRADEMARKS All brand and product names are trademarks or registered trademarks of their respective companies. NOTE The information in this manual

More information

User Guide 1U RAID Rack with esata /U3 /FW800 (R1ESU3F)

User Guide 1U RAID Rack with esata /U3 /FW800 (R1ESU3F) T E C H N O L O G I E S User Guide 1U RAID Rack with esata /U3 /FW800 (R1ESU3F) v6.1.11 Technical Support If you need any assistance to get your unit functioning properly, please have your product information

More information

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions

HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions HP P6300/P6500 EVA Fibre Channel Controller Replacement Instructions About this document For the latest documentation, go to http:// www.hp.com/support/manuals, and select your product. The information

More information

Dell PowerEdge T110 Systems. Hardware Owner s Manual

Dell PowerEdge T110 Systems. Hardware Owner s Manual Dell PowerEdge T110 Systems Hardware Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

QuickSpecs. HPE Integrity Smart Array P411/256 2-port External PCIe 6Gb SAS Controller. Overview. What's New Boot from Tape

QuickSpecs. HPE Integrity Smart Array P411/256 2-port External PCIe 6Gb SAS Controller. Overview. What's New Boot from Tape HPE Integrity Smart Array P411/256MB 2-Port External PCIe 6Gb SAS Overview The HPE Smart Array P411 is HPE's external connect only, PCI Express (PCIe) 2.0 Serial Attached SCSI (SAS) RAID controller for

More information

RocketU 1144BM Host Controller

RocketU 1144BM Host Controller RocketU 1144BM Host Controller USB 3.0 Host Adapters for Mac User s Guide Revision: 1.0 Oct. 22, 2012 HighPoint Technologies, Inc. 1 Copyright Copyright 2012 HighPoint Technologies, Inc. This document

More information

Interpret control-panel messages

Interpret control-panel messages Interpret control-panel messages Control-panel message types Four types of control-panel messages can indicate the status of or problems with the product. Message type Status messages Warning messages

More information