User Guide for NR-W devices Version 1.1

Size: px
Start display at page:

Download "User Guide for NR-W devices Version 1.1"

Transcription

1 User Guide for NR-W devices Version 1.1 User Guide Page 1

2 Disclaimer of Warranties IMPORTANT: Sensors, software, documentation, and other products offered by Spectral Engines Oy, hereinafter referred to as the Products, are not designed to be fault-tolerant and therefore they are not intended to be used for the purposes of life-critical or hazardous environments that require fail-safe performance. To the maximum extent permitted by law, Spectral Engines Oy disclaims any and all warranties, whether expressed or implied, including without limitation any implied warranties of title, merchantability, or fitness for any particular purpose, regarding the Products. Without limiting the foregoing, Spectral Engines Oy expressly does not warrant that: 1. the Products will meet your requirements or expectations; 2. the Products will be free of bugs, errors, viruses, or other defects; 3. any results, output, or data provided through or generated by the Products will be accurate, up-to-date, complete, or reliable; 4. the Products will be compatible with any third party software or products; or 5. any errors in the Products will be corrected. To the maximum extent permitted by law, neither Spectral Engines Oy nor its suppliers will be liable for any damage or losses relating to the use of the Products, including without limitation direct, indirect, special, consequential, punitive or incidental damages, or losses of revenue, profit, or data. In any case the maximum liability of Spectral Engines Oy will be equal to the purchase price of the Products. If you have duly acquired a license to software, you shall have a limited, non-exclusive right to install the software and operate the software but solely in connection with the Products according to relevant specifications and user guides. Save for your limited license, title and all intellectual property rights to the Products belong exclusively to Spectral Engines Oy and its suppliers. Your limited license to the software will be governed by the substantive laws of Finland. This user guide is subject to revision without notice Spectral Engines Oy. All rights reserved. User Guide Page 2

3 Welcome to Spectral Engines Sensor Control. This guide instructs you on how to set up your new sensor and use its key features. Before starting please check that you have the following accessories on hand: 1. A suitable measurement PC, which has a compatible operating system, such as Windows XP, Windows Vista, Windows 7, or Windows A USB cable, Type A Micro-B, for connecting the sensor to the computer. 3. Spectral Engines Sensor Control software installation package. Separate software packages are available for 32- and 64-bit versions of Windows. You may find the software either on a USB Flash drive supplied or you can download the software from Download section on the Spectral Engines website at 1. Installation Do not connect the device to the computer before the Spectral Engines Sensor Control software has been installed. Spectral Engines offers different types of NR-W spectral devices. The devices operate in the nearinfrared spectral region, are designed especially for reflectance measurement, and are wireless. NR-W devices include: NR-1.7-W, from 1350 to 1650 nm NR-2.0-W, from 1550 to 1950 nm NR-2.2-W, from 1750 to 2150 nm The NR-W Wireless Spectral Devices are ideal for reflection measurements from solid materials. It has integrated tungsten light sources. The has a Li-ion battery that can be charged through the USB connector (type Micro B). To begin using your new device, you first need to install the Sensor Control software. The installation package contains the necessary USB drivers for the device, and the drivers will be found in the Sensor Control installation folder. After the USB drivers have been installed, you are ready to use the device. NB: the ZIP file must be unzipped into a file folder. In latest versions of Windows it is possible to simply navigate into the ZIP file and attempt the installation from there. In most cases this will generate errors and you will not be able to finish the installation. 1.1 Software and Drivers Installation Run setup.exe in Spectral Engines Control Software root folder and follow the instructions. This will install the Sensor Control Software, drivers and documents. The default folder is C:\Program Files\Spectral Engines\. After the software installation has finished, the USB drivers must be installed. User Guide Page 3

4 1.2 USB Driver Installation Connect the device to the computer with the USB cable. The system automatically prompts you to search for the needed drivers. If not, a manual installation can be done in Device Manager in Windows Control Panel. An unidentified LPC device should be listed under Other devices category. Right-click on this item and select Update Device driver. Picture: In the Windows Device Manager, an unidentified LPC device can be found under Other devices category once the sensor has been connected to the system, but before the USB driver has been installed. In the pop-up window, select Browse my computer for driver software. Then go to the Sensor Control Software installation folder and select the USB driver subfolder. Default path is C:\Program Files\Spectral Engines\USB Driver. Then click Next. After the driver installation is complete, the device will show up in Windows Device Manager under Ports (COM & LPT), with item name as LPC13xx USB VCom Port. During the installation, the Windows Security will possible notify that it cannot verify the publisher of the software. Ignore this alert by selecting Install this driver software anyway to continue installation. When Windows has successfully finished installation of the driver software, you are ready to use the software. NB: if you are using Windows 8 operating system, please see installation help in the Troubleshooting section at the end of this manual (p. 16). User Guide Page 4

5 2. Getting started After the Sensor Control software and USB drivers have been properly installed, you are ready to begin using your new device. Start the Sensor Control software by clicking on the shortcut in Windows Start-up à Spectral Engines à SensorControl. The software will automatically detect and set up the device with default settings, and will start to measure spectra. Suggested basic operation of the system: 1. Set the measurement settings: Wavelength points Averaging Mode (Averaging/Buffering) Averaging parameter. Recommendation is to use values between 100 and 500 at least. 2. Measure a dark signal: block all light from reaching the sensor. Then press the Dark button on the main screen to measure the dark signal spectrum. An alternative with certain products you may use the Auto Lamp Mode with Dark Subtraction and skip this phase. 3. Measure a reference signal. Turn on your light source. We recommend using 100% lamp intensity setting if possible. Press Reference button on the main screen to measure the reference spectrum. The raw signal should be less than DN units on all measured wavelength. 4. You can now measure and save sample spectra. 2.1 Introduction of the NR-W devices Figure 1: LED indicators (1 and 2), USB connector (3) and On/Off switch (4) of the NR-W device. User Guide Page 5

6 The NR-W device is suitable for use with the Sensor Control software on Windows PCs, and with Android tablets and smartphones using the SimpleSample Android software. The NR-W devices must be connected to the PC using either the USB cable or the Bluetooth connection. When using Android tablets and smartphones, the device must be connected using the Bluetooth connection. For using the NR-W devices with the SimpleSample software, please refer to the User Guide for SimpleSample. The connection panel of the NR-W device has two LEDs, a USB connector and an On/Off switch. The first LED (1) is the Power Indicator. This green LED is lit when the device is powered up, and unlit when the power is off. The second LED is the Charge LED. This orange LED is lit when the device is charging the Li-ion battery via the USB connection, and unlit when the system is not charging. Fully charged battery may last up to 150 minutes of continuous use. The USB connector is of type USB Micro B. The system can be connected to a wall plug (using an adapter) or to a computer using this connector with the provided cable. The NR-W devices have an optical interface for reflectance measurements. The sample measurement spot is at the round optical window. The devices have a twin light source configuration, and the light intensity of the light sources can be adjusted in the measurement software. Figure 2: View of the reflectance measurement side of the NR-W. The measurement spot is at the round window at the lower right corner of the box. User Guide Page 6

7 3. Sensor Control layout and functions The device is fully controlled by the Spectral Engines Sensor Control software. When the program is started, it will start measuring new spectra automatically. Basic functionalities include measuring dark level signal and/or reference signal levels, setting measurement parameters, saving measurement raw spectra, and selecting how to display the measured spectra on screen. Above: screenshot of the main view screen for NR-W device when used with the Sensor Control software, displaying the Measurement tab. The software view is divided into four view sections. Main view section and its functions are on screen all the time. Alongside the main view, a switchable subview will be visible at the center of the program screen. The three subviews are the Measurement, Settings and Analysis. These subviews are on their separate tabs. 3.1 Main view Main view and its components are related to basic measurement commands and status of the device. The Measure, Dark, Reference, Save and Exit buttons are on the top right part of the screen. Measure starts and stops the measurement mode. When measurement mode is active, the button color is dark grey. When mode is deactivated, color changes to white. Dark is the dark signal levels measurement button. The dark signal should be measured at the start of a new set of measurements, with the light source off. After a dark signal has been measured, the color of this button changes from white to green. Clicking on the User Guide Page 7

8 button again after the dark signal has been measured forces the software to unload the value, so that a new dark signal can be measured Reference is the background or full signal level spectrum, which should be measured at the start of a new set of measurements, with the light source turned on. Clicking on the button again after the reference signal has been measured forces the software to unload the value, so that a new dark signal can be measured Save button starts and ceases a save cycle. The save cycle settings are under the Settings tab. When save mode is activated, the button turns from white to dark grey. Exit button ends the measurement and closes the Sensor Control program. The buttons will have varying coloration depending on the status of the function: Translucent: deactivated. This happens in the case of Auto Lamp mode with Dark Subtraction being enabled. More about this in Section 3.3 Settings Screen. White: inactive. The function is not in use, or signal has not been measured. If a dark/reference was measured previously, it has been released from memory. Grey: function is active, or signal is being measured at the moment. Green: signal has been measured successfully and saved to memory. On the upper right corner, below Sensor Control text, will be the general type identifier of the sensor in use. This will be automatically identified when the sensor has been found the software. More specific sensor identification data is found on the Settings tab. Finally, on the bottom part of the screen is the Status bar. This will display general status messages of the sensor, and possible operation errors. During sensor start-up, this part will display status of the automatic device search and setup. 3.2 Measurement screen The Measurement tab has a visual display of the latest measured spectrum, with user-selectable display value range, and fully configurable visual display options. The Point Average and Scan Average values are also displayed and changeable on this page. The lamp voltage control for Spectral Engines tungsten filament type light sources is also on this page, in the bottom left corner. User Guide Page 8

9 The components visible on the measurement screen: The Status signals for System Status, Save Mode, and Measurement mode are visible on the middle right side of the screen. System Status light Unlit: a sensor has not been detected by the software. Lit: sensor has been detected is ready for operation. Save mode status light Disabled: sample saving is not active. Unlit: save cycle is active, waiting for next save timepoint in the cycle. Lit: a sample spectrum is being saved. Measurement mode status light Disabled: measuring mode has been disabled. Unlit: measuring mode active, sending latest measurement data, readying for next measurement. Lit: measuring mode active, measuring new data. Visual display of the latest measured spectrum. X-axis values are by default different wavelengths, scaled automatically according to the sensor specification. Y-axis values are user-selectable with the Display Mode selector on the bottom left corner. Three default options are: o Raw intensity signal value, which has a scale of o Transmission/reflectance value (% units). o Absorbance units, where absorbance A = -log 10(Reflectance). Changing the display mode during measurements will force next completed measurement to be displayed with the new display setting. The display settings can be modified through buttons on the bottom right corner of spectrum display. NB(1): right-clicking on the Y- or X-axis will show a menu, where it is possible to enable or disable the autoscaling for the axis in question. NB(2): the Display Mode selector is only available for selection if the Dark and/or Reference values have been measured (lit green). Otherwise only the Raw Intensity option will be available. The Measurement tab also contains the selectors for Integration time, Averaging value, and Averaging mode. Point Average setting tells the amount of measurement samples taken for every wavelength point. The displayed result will be updated once the averaging is completed. This mean value calculation is done in the sensor hardware. Minimum and maximum values are 1 and , respectively. Scan Average is the number of individual full spectra that will be used to calculate an average spectrum. The spectra will only be updated once all of the individual spectra have been measured. Minimum and maximum values are 1 and 1 000, respectively. User Guide Page 9

10 On the middle bottom part of the Measurement screen are the Freeze buttons and the Scale button and wavelength selector. The main Freeze button is used to activate and deactivate the Freeze 1, 2 and 3 buttons. When the main function is active, pushing these three buttons will save the next measured spectrum into temporary memory, and the spectrum will be frozen on the screen. The individual spectra can be released by pressing the button again. Releasing the main Freeze button will release all the Freeze buttons at once. The Scaling function is used to scale the frozen and latest measured spectra on the screen. Pressing the button activates and deactivates the scaling to the set value. The Lamp Voltage control will allow you to set the voltage level of the Spectral Engines tungsten filament light sources. This applies to devices with integrated light sources. When the spectral device is first detected, this feature will be enabled. Clicking on the lamp voltage setting will reveal a dropdown menu, with settings for lamp voltage between 0 and 100 %, in 25 % increments. The new setting will be applied upon selection. The latest setting used for the spectral device will be saved in the Settings.ini file upon exiting the software via the Exit Button. 3.3 Settings screen On the Settings tab, the settings for spectral measurement points and saving data are displayed and configurable. The port settings for the sensor are on this tab, as are the sensor-specific identification data. Also, if a software error is encountered, a Clear Error button will be shown on this screen. Above: general view of the software with Settings tab open. Measurement settings subwindow contains the settings for the spectrum measurements. Two standard modes are offered: Full spectrum measures data points from the entire wavelength range of the sensor. The default first and last wavelengths are the minimum and maximum wavelengths of the User Guide Page 10

11 sensor. The step or separation of each consecutive spectral data point can be changed. After setting values and clicking the Update button, the number of sampled wavelengths will change. In Manual selection mode, the user can enter all the wavelengths that will be measured manually into a list. Simply type the wavelengths (in nm) to the list, press Return on the keyboard to add a new row. After clicking the Update button, the program will check the entered values against the sensor s wavelength range. The points outside of the sensor s range will be discarded. It is possible, however, to measure a single spectral wavelength multiple times in single measurement. For the NM modules and N-series sensors when used together with an LS-PRO light source, it is possible to select different modes of operation for the light source. Manual mode: light source is powered manually by selecting the lamp source intensity on the Measurement tab. Auto lamp mode: the light source is automatically switched off when not in use. The Dark signal will need to be measured manually at the start of the measurements. Auto lamp with dark subtraction: the light source is automatically switched on and off. Additionally the Dark signal will be measured every time before a new sample spectrum is measured, with the light sources off. The Dark signal is automatically subtracted from the sample spectra, and the individual Dark signals will not be saved. This is the recommended use mode for NR-W devices and NM-series modules. NB! In Full spectrum mode, the step calculation is started from the first wavelength value. Example: if the first WL is 1605, last WL is 1800, and the step is 40 nm, then the spectrum wavelengths will be 1605, 1645, 1685, 1725, and Pictures: Full spectrum settings (left), and Manual selection settings (right). Port settings allow you to change the port selection of the software from automatic to manual. This must be done only when the automatic detection of the sensor does not work. To manually select the port from the list, change the Port Selection mode from Automatic Detection to User Selectable Port, the scroll the COM Port dropdown list to select the port manually. User Guide Page 11

12 Picture: Port Settings on the Settings tab. Save settings allow you to set the file path, file name, and general save cycle settings. Number of measurements is the number of spectra that will be saved in one cycle. Interval tells the time separation of each spectrum save, in seconds. Each save cycle is started by pressing the Save button on Measurement screen. This value can be set to 0, so every single spectrum will be measured. Example: with save count set to 10 and save interval of 6 seconds, a spectrum will be saved every 6 seconds, and the save cycle total time is 60 seconds. The save file name will be automatically updated when the Measurement settings are adjusted by pressing the Update button in the Measurement settings subwindow. The default file name is the current date and time in the format YYYY-MM-DD_hh-mm-ss. It is possible to save both the raw data and absorbance data values at the same time, as well as the results of the active Analysis method. All three datasets will be saved into separate files. The different saved files can be identified by their suffixes: raw, absorbance, and analysis. Default setting is that only the raw data is saved. Picture: Save settings subwindow on the Settings tab. Device Identification information is automatically updated for every connected sensor. This screen displays sensor-specific identification data, such as the type and version of the sensor, serial number, manufacturing date and firmware version. It is also possible to check the temperature of the sensor or module using the READ TEMP button in the Device Identification information. Pressing the button will prompt a single new reading from the device, and it will be updated once the measurement cycle is finished. User Guide Page 12

13 Picture: example of data shown in Device Identification for an NM2.2 device. In the case of sensor or software errors, a Clear Error button will be visible on the right side of the Device Identification window. Pressing this button will clear the Error from memory. Still should be done only after the Error has been solved. The measurement settings set by the user for every sensor used are automatically saved in a file called Settings.ini. The settings are automatically saved to this file upon quitting the program. The saved information includes: Integration time Point Average value Measurement settings for both Full spectrum and Manual selection modes Lamp voltage setting in use This information is sensor-specific, and will be matched to the sensor s serial number. The Settings.ini can be found at the folder: C:\Users\ user \AppData\Local\SpectralEngines Please note that the AppData folder is typically hidden. The name for the first User folder depends on your Windows language version. user is your Windows username. 3.4 Analysis screen Functions on the Analysis tab can be used to track the variance of the measurement data. Currently two general functions are available, Difference and Ratio. Both methods require input from the user, in the form of reference and measurement center wavelengths, and widths of these two ranges. On the Analysis tab the word Reference WL does not relate to the Reference Signal that has been measured for the measurements. The Reference WL and Meas WL are both simply wavelengths or mean values over multiple wavelengths in the same sample spectra that are measured from samples. The Reference WL is a baseline wavelength or baseline region in the measured spectrum. In an ideal case this Reference WL would not contain any variance over the samples, although in some cases this is impossible to achieve. The Meas WL is then the wavelength or wavelength region where the variance of the signal, in relation to the Reference WL, will be monitored. User Guide Page 13

14 The Reference and Measurement wavelength settings function as such: Center wavelengths are set by inserting the values into the corresponding selectors. These wavelengths do not need to be wavelength points that are measured in the current spectrum. For example, if the current spectrum contains points 1840, 1850, 1860 and 1870 nm, you can still insert any whole number from this range. The width parameter is the width of the range. If the center wavelength is 1850 nm, and width is 10, the range is 1845 to 1855 nm. All points that fall within the range defined will be used in the calculation of an average value that will be used in the Difference or Ratio value calculation, depending on which setting is chosen at the time. If the settings are such that no measured wavelength points are in the range, the system will automatically calculate a value using interpolation from the first lower and higher wavelength points available. Example: measured points are 1850 and 1860 nm. Center wavelength point is 1855, and range is 8. No points are reached, as the wavelength range covers only 1851 to 1859 nm. The system interpolates a single data point at 1855 from the values of 1850 and 1860 nm. The actual values used in the calculation can be either raw signal, transmission/reflectance or absorbance values. The currently used signal is displayed in the Display mode text box on the lower left corner of this screen. This mode can be changed from the Display mode selector on the Measurement screen. The Difference and Ratio values are calculated through the following equations: Difference: X = Measurement value Reference value Ratio: X = :; <5=74 >4?484:@4 <5=74 User Guide Page 14

15 As an option, it s also possible to scale the results of these methods with a simple linear function of the type Y = ax + b, where a is the slope, b is the offset, X is the calculated Difference or Ratio value. The calculated results are displayed both in the graph in the middle of the screen as a function of time, and the latest value is also displayed in the Results field on the right side of the screen. The result time graph can be cleared of all values using the Clear Graph button in the lower left corner of the screen. User Guide Page 15

16 Troubleshooting Problem: USB driver installation is cancelled, as Windows encounters a problem: The third-party INF does not contain digital signature information. Solution: Windows Vista/7/8 have by default a Security Policy due to which you might not be able to install the USB Driver directly. The solution is to circumvent the Security Policy temporarily by manually disabling driver signature enforcement in Windows start-up settings. To do this, you will need to access Advanced Start-up settings or Advanced Boot options of your Windows PC. There are at least two ways to do this: 1) Restart the computer, and during start-up (after BIOS prompt screens have passed), press F8. Advanced boot options will be displayed. As one of the last options will be Disable Driver Signature Enforcement. Select this option, and restart and proceed to Windows normally, and then install the USB drivers. 2) In Windows 8, open the Settings sidebar on Windows 8 Desktop (mouse cursor to top right corner, then wait), then select the following: Change PC settings à Update & Recovery à Recovery à Advanced Start-up A screen titled Choose an option should pop-up. Select: Troubleshoot à Advanced options à Start-up settings à Restart You will get to the same Startup settings screen as in the first method. Select the option Disable Driver Signature Enforcement, then reboot to Windows normally, and install the USB drivers as instructed. Problem: An error message on the Measurement settings states: Too many points. Cropped from the shorter wavelengths. Solution: The maximum amount of wavelength points for a single spectrum is 511. If the calculated amount of points exceeds this value, the datapoints corresponding with the shorter wavelengths on the demanded range will be removed. Problem: The sensor cannot be found, or computer has problems communicating with the sensor. Solution: Detach the USB cable from the computer, wait for 10 seconds, and re-attach. If the problem persists, contact Spectral Engines Oy. Up-to-date contact information can be found on the Spectral Engines website at Problem: An error is displayed on the status bar. Solution: Possible error codes and their reasons: User Guide Page 16

17 Error 4001 Error 4002 Generic data transfer error code. Check the cable connections, and reconnect the sensor to the measurement computer. You will need to measure dark and reference signal values again. Total measurement time has exceeded 1000 seconds. Lower the total measurement time by adjusting the values for Averaging, Integration time and number of wavelengths. Then Press the Clear Error button on the Settings tab before continuing measurements. Problem: When trying to save spectral measurement data, an error message shows up on the Status bar. Solution: Possible errors when trying to save data, and how to solve them include: Error 7 The Save file path is invalid, it does not exist. This function does not have the capability of creating a new folder. Solution: Change the file path to an existing location. Error 8 The Save file path is invalid, it is restricted by Windows Security Policy. Locations include root of main hard disk drive (C: by default) and Windows folder. Solution: Change the file path to a nonrestricted location. User Guide Page 17

Sensor Control User Guide Version 2.6

Sensor Control User Guide Version 2.6 Sensor Control User Guide Version 2.6 Software for spectral sensors and devices User Guide Page 1 Disclaimer of Warranties IMPORTANT: Sensors, software, documentation, and other products offered by Spectral

More information

USB Server User Manual

USB Server User Manual 1 Copyright Notice Copyright Incorporated 2009. All rights reserved. Disclaimer Incorporated shall not be liable for technical or editorial errors or omissions contained herein; nor for incidental or consequential

More information

STOP! Read these instructions before connecting the PR3 to your Computer

STOP! Read these instructions before connecting the PR3 to your Computer Windows 10 Installation Instructions for the PR3 NOTE: If Windows 10 installed the drivers for the PR3, these instructions are not needed. These instructions are only to be used if Windows 10 did not automatically

More information

1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2

1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2 - i - Table of Contents 1. Introduction... 1 Features... 1 Package Contents... 1 System Requirements... 1 LED Status... 2 2. Installation... 3 Windows 7/ Vista... 3 Windows XP... 5 Windows 2000... 7 Windows

More information

TEMPINSPECT USB Single-use and Multiuse. USB DRIVER INSTALLATION FOR WINDOWS 7 AND 8 For use with the Tempinspect Configuration Tool Software

TEMPINSPECT USB Single-use and Multiuse. USB DRIVER INSTALLATION FOR WINDOWS 7 AND 8 For use with the Tempinspect Configuration Tool Software TEMPINSPECT USB Single-use and Multiuse USB DRIVER INSTALLATION FOR WINDOWS 7 AND 8 For use with the Tempinspect Configuration Tool Software COLDCHAINVISION SA 2018 1. General Information If you are using

More information

SaviSign Manager User Manual

SaviSign Manager User Manual SaviSign Manager User Manual Digital Signage Management Software For The P100 Signage Player For use with Windows 7 or Higher Easy-to-use, powerful software Perfect for crafting digital signage displays!

More information

Bluetooth 4.0 USB Adapter Model

Bluetooth 4.0 USB Adapter Model Bluetooth 4.0 USB Adapter Model 604002 Windows OS 8.1/10: Drivers auto-install 7/Vista/XP: Drivers are required Quick Start Guide Download drivers at cablematters.com/downloads Email: support@cablematters.com

More information

Bluetooth 4.0 USB Adapter

Bluetooth 4.0 USB Adapter Bluetooth 4.0 USB Adapter Model 604002 Supports Windows XP, Vista, 7, 8.1, 10 Windows 8.1 and 10 auto-installs Bluetooth drivers Drivers on DVD for Windows XP, Vista, 7 (download from Cable Matters) Pair

More information

12.0 Setting up the PC ready for BESA 11

12.0 Setting up the PC ready for BESA 11 12.0 Setting up the PC ready for BESA 11 12.1 - Installing Driver. Important Note: Before you start to install the driver, please do not plug BESA 11 into the computer s USB port or else the installation

More information

Rail Departures V2 Installation Guide

Rail Departures V2 Installation Guide Rail Departures V2 Installation Guide 30/11/2015 1 WHAT'S INCLUDED Rail Departures V2 Board 5V 8A Power adaptor Mains power cable with UK plug x1 x1 x1 LED PANEL WARRANTY: Any panel with a severe defect

More information

ADN. System Installer. Instruction manual

ADN. System Installer. Instruction manual ADN System Installer Instruction manual Content Content Installation requirements... 4 Selecting updates... 4 ADN System Update... 5 Establishing the connection... 5 Overview of the update stage window...

More information

CellSync Manager. User Manual F8V7D006-SS F8V7D008-SS. Get online and synchronize anywhere. Web Access. Phone Book Manager

CellSync Manager. User Manual F8V7D006-SS F8V7D008-SS. Get online and synchronize anywhere. Web Access. Phone Book Manager CellSync Manager Get online and synchronize anywhere Web Access Phone Book Manager User Manual F8V7D006-SS F8V7D008-SS TABLE OF CONTENTS Introduction...2 Interactive Phone Menu...3 LG 5350 CellSync Software

More information

INSIGHT Installation Instructions

INSIGHT Installation Instructions This is the New Icon that will appear on your computer screen after the INSIGHT v8.1 software is installed. IMPORTANT: These instructions pertain to version 8.1.29. INSIGHT v8.1.29 requires Windows 8,

More information

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro

CVI SPECTRAL PRODUCTS. 111 Highland Drive Putnam CT, (860) SM32Pro CVI SPECTRAL PRODUCTS 111 Highland Drive Putnam CT, 06260 (860) 928-5834 SM32Pro 2.8.28 Table of Contents Warranty and Liability 1 Quick Start Installation Guide 2 System Requirements 3 Requirements for

More information

Quick Start Guide: Welcome to OceanView

Quick Start Guide: Welcome to OceanView Quick Start Guide: Welcome to OceanView Contents: Ctrl + Click a Topic Below for More Information Introduction to OceanView... 3 Welcome Screen... 3 Data Window... 3 Schematic View... 3 Persistence...

More information

Table Contents. Introduction Key Features...2. Getting Started Package Contents...3. Minimum System Requirements...3

Table Contents. Introduction Key Features...2. Getting Started Package Contents...3. Minimum System Requirements...3 1 Table Contents Introduction... 2 Key Features...2 Getting Started... 3 Package Contents...3 Minimum System Requirements...3 Driver Installation...3 Applications Installed...7 BlueSoleil... 8 Main Windows...8

More information

Workshop 4 Installation INSTALL GUIDE. Document Date: February 4 th, Document Revision: 1.1

Workshop 4 Installation INSTALL GUIDE. Document Date: February 4 th, Document Revision: 1.1 INSTALL GUIDE Workshop 4 Installation Document Date: February 4 th, 2013 Document Revision: 1.1 Description This document describes how to install and configure Workshop 4, and how to install the driver

More information

GSC400 Series. GSC400 Programmer and PC Interface User Manual

GSC400 Series. GSC400 Programmer and PC Interface User Manual GSC400 Series GSC400 Programmer and PC Interface User Manual GSC400 Programmer and PC Interface User Manual Full Version File: GSC400 PC Interface Rev1.5.doc, December 2010 2 of 42 Thank You For Purchasing

More information

pindmd3 Installation Guide

pindmd3 Installation Guide pindmd V3 Installation Guide 30/11/2015 1 WHAT'S INCLUDED pindmd3 RGB Panel / Diver Board USB Interface Cable x1 x1 LED PANEL WARRANTY: Any panel with a severe defect will be replaced under warranty. This

More information

SmartScan. Barcode Translator for QuickBooks USER S MANUAL

SmartScan. Barcode Translator for QuickBooks USER S MANUAL SmartScan Barcode Translator for QuickBooks USER S MANUAL Baus Systems 4727 44 th Ave. SW, Suite 202 Seattle, WA 98116 (206) 932-9986 Office (206) 923-0839 Fax E-mail: support@baus-systems.com 1 TABLE

More information

Key Features: Be notified of incoming calls, texts, , calendar and social media events with vibration and LED light

Key Features: Be notified of incoming calls, texts,  , calendar and social media events with vibration and LED light Product Overview Congratulations on your purchase of the MARTIAN WATCH! MARTIAN provides you with connectivity to your voice-command-enabled smartphone or tablet via Bluetooth wireless technology. Key

More information

Installing an OptoBlue Adaptor on Windows 8 Operating System:

Installing an OptoBlue Adaptor on Windows 8 Operating System: Installing an OptoBlue Adaptor on Windows 8 Operating System: Before beginning this process, be sure to save all your work in any open programs. Your computer will reboot during this process. Settings

More information

Hitachi U-2001 UV/Vis Spectrometer Updated November 14, 2017

Hitachi U-2001 UV/Vis Spectrometer Updated November 14, 2017 Hitachi U-2001 UV/Vis Spectrometer Updated November 14, 2017 Instrument instructions can be found at: http://academic.bowdoin.edu/chemistry/resources/instructions.shtml If you have any problems with the

More information

Instructions for Installing FlashUpdate and Downloading Updates for NPRT 2200 Noise Power Ratio Test Set

Instructions for Installing FlashUpdate and Downloading Updates for NPRT 2200 Noise Power Ratio Test Set Instructions for Installing FlashUpdate and Downloading Updates for NPRT 2200 Noise Power Ratio Test Set Updates to the instrument firmware are available from the Applied Instruments website. Requirements

More information

1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically.

1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically. 1) Installing Bluetooth software for Windows (A) Place installation CD into PC and setup should launch automatically. If setup does not launch, use Windows Explorer to navigate to the appropriate CD- ROM

More information

On-board wireless temperature and humidity logger

On-board wireless temperature and humidity logger On-board wireless temperature and humidity logger v6.3 BT 1 Contents 1. Introduction... 4 2. Description of the operation... 4 3. Technical data... 6 4. Loggicar R package contents... 7 5. Logger overview...

More information

FES BMS CONTROL MANUAL

FES BMS CONTROL MANUAL FES BMS CONTROL MANUAL Version 1.26 for BMS control software version 1.31 Suitable for: -FES BATTERY PACK GEN1 (with external BMS-7R) -FES BATTERY PACK GEN2 (with internal BMS-9R) LZ design d.o.o., Brod

More information

Remote Display User Manual

Remote Display User Manual Remote Display User Manual 1 Contents Features... 3 Hardware Overview... 4 Quickstart Guide... 5 Android Application Operation... 6 Launching and Connecting... 6 Main Display... 7 Configuring Channels...

More information

SC-01 Data Logger Management Program Operator s Manual

SC-01 Data Logger Management Program Operator s Manual SC-01 Data Logger Management Program Operator s Manual Part Number: 71-0138RK Revision: P1 Released: 9/12/07 www.rkiinstruments.com Warranty RKI Instruments, Inc., warrants gas alarm equipment sold by

More information

TRENDnet User s Guide. Cover Page

TRENDnet User s Guide. Cover Page Cover Page Table of Contents Contents Product Overview... 2 Package Contents... 2 Features... 2 Product Hardware Features... 3 Application Diagram... 4 Installation - Hardware... 4 Adapter... 4 Fiber Cable...

More information

The merisuite CG Application

The merisuite CG Application The merisuite CG Application Copyright 2017 Meriam Content The merisuite CG Application...1 Content... 2 General information...3 Notification Statements... 3 Disclaimer... 3 Glossary... 4 Features...5

More information

CDC-ACM Driver for Windows Installation Guide

CDC-ACM Driver for Windows Installation Guide CDC-ACM Driver for Windows Installation Guide Version 1.00 For use with CDC-ACM Class Driver Versions 1.0 and above Date: 27-May-2014 09:56 All rights reserved. This document and the associated software

More information

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1

BrewTroller Phoenix. Owners Manual. Updated - March 14, 2016 BREWTROLLER PHOENIX 1 BrewTroller Phoenix Owners Manual Updated - March 14, 2016 BREWTROLLER PHOENIX 1 2016 BrewTroller All Rights Reserved. Product warranty or service will not be extended if: (1) the product is repaired,

More information

Meso LED Driver stands for an extremely flexible LED Driver, designed for fast and easy configuration.

Meso LED Driver stands for an extremely flexible LED Driver, designed for fast and easy configuration. Introduction Meso LED Driver stands for an extremely flexible LED Driver, designed for fast and easy configuration. This Application Note AN3_ illustrates the setting options of the Meso LED driver in

More information

10 Digital Photo Frame Instructional Manual

10 Digital Photo Frame Instructional Manual 10 Digital Photo Frame Instructional Manual aluratek.com mnl M10403 model ADMPF410T Copyright 2016 Aluratek, Inc. All Rights Reserved. Table of Contents Frame Features... Frame Control Close-up... Remote

More information

& Technical Specifications

& Technical Specifications User Manual & Technical Specifications User manual Contents Pidion BM-170 Technical specifications... 2 Micro Rolltalk basic package... 3 Micro Rolltalk functions and buttons... 3 Preparing Micro Rolltalk...

More information

2.4GHz Wireless Optical Mouse

2.4GHz Wireless Optical Mouse 2.4GHz Wireless Optical Mouse Model #: MP1950BLK User Manual PID #: 111587-109342 Rev. 140402 All brand name and trademarks are the property of their respective companies Mac and Mac OS X are registered

More information

2017 WorkPlace Mobile Application

2017 WorkPlace Mobile Application 2017 WorkPlace Mobile Application User Guide Paramount WorkPlace 2017 and Greater Table of Contents OVERVIEW... 3 GETTING STARTED... 3 Communication Architecture... 3 Mobile Device Requirements... 4 Establish

More information

Mini Document & Photo Scanner. i-convert

Mini Document & Photo Scanner. i-convert Mini Document & Photo Scanner Ultra-portable scanner scans anywhere i-convert Table of contents Warnings and Cautions....................................................... 2 LCD Screen Icons............................................................

More information

PCMCIA Flash Card User Guide

PCMCIA Flash Card User Guide R R PCMCIA Flash Card User Guide For the CoreBuilder 3500 System Introduction The CoreBuilder 3500 PCMCIA Flash Card is a 20 MB flash card that you can use to save your system software. When you have saved

More information

Wi-Fi HDD Docking Station WITH SuperSpeed USB 3.0

Wi-Fi HDD Docking Station WITH SuperSpeed USB 3.0 Wi-Fi HDD Docking Station WITH SuperSpeed USB 3.0 USER MANUAL www.cablematters.com Table of Contents 1. Introduction 2 1.1 Introduction 1.2 Copyright and Trademarks 2. Product Overview 3 2.1 Package Contents

More information

Spectrometer Visible Light Spectrometer V4.4

Spectrometer Visible Light Spectrometer V4.4 Visible Light Spectrometer V4.4 Table of Contents Package Contents...3 Trademarks...4 Manual Driver and Application installation...5 Manual Application Installation...6 First Start of the Application...8

More information

Log & Event Manager UPGRADE GUIDE. Version Last Updated: Thursday, May 25, 2017

Log & Event Manager UPGRADE GUIDE. Version Last Updated: Thursday, May 25, 2017 UPGRADE GUIDE Log & Event Manager Version 6.3.1 Last Updated: Thursday, May 25, 2017 Retrieve the latest version from: https://support.solarwinds.com/success_center/log_event_manager_(lem)/lem_documentation

More information

Bluetooth Wireless Technology Enabled Optical Mouse

Bluetooth Wireless Technology Enabled Optical Mouse Bluetooth Wireless Technology Enabled Optical Mouse Model BT9400WHT/BT9500BLK User Manual PID # 111536/7-109289 Rev. 140619 All brand name and trademarks are the property of their respective companies.

More information

Professional Jukebox Software

Professional Jukebox Software Professional Jukebox Software Exclusively distributed by Contents Security devices Page 3 The Load program Page 4 Music encryption Page 5 Splash screen Page 6 Main screen Page 7 Button Mode Page 8 Selecting

More information

PocketWeave User s Manual

PocketWeave User s Manual PocketWeave User s Manual Version 1.1 Written by Kriston M. Bruland AVL Looms 3851 Morrow Lane, Suite #9 Chico, CA 95928-8305 U.S.A. 530 893-4915 530 893-1372 (fax #) info@avlusa.com (e-mail) www.avlusa.com

More information

APPLICATION NOTE. Application Note: 4D-AN-P4007. ViSi-Genie Play Video. Document Date: November 15 th, Document Revision: 1.

APPLICATION NOTE. Application Note: 4D-AN-P4007. ViSi-Genie Play Video. Document Date: November 15 th, Document Revision: 1. APPLICATION NOTE Application Note: ViSi-Genie Play Video Document Date: November 15 th, 2012 Document Revision: 1.0 Description This Application Note explores the possibilities provided by ViSi-Genie for

More information

Ludlum Lumic Data Logger Software Manual Version 1.1.xx

Ludlum Lumic Data Logger Software Manual Version 1.1.xx Ludlum Lumic Data Logger Software Manual Version 1.1.xx Ludlum Lumic Data Logger Software Manual Version 1.1.xx Contents Introduction... 1 Software License Agreement... 2 Getting Started... 5 Minimum

More information

ZP Recorder INSTRUCTION MANUAL. Force Data Analyzer. For Force Gauge Models: ZP, ZPH and ZPS

ZP Recorder INSTRUCTION MANUAL. Force Data Analyzer. For Force Gauge Models: ZP, ZPH and ZPS ZP Recorder Force Data Analyzer For Force Gauge Models: ZP, ZPH and ZPS INSTRUCTION MANUAL 2 YEAR WARRANTY (RESTRICTIONS APPLY) Imada, Inc. warrants its products to the original purchaser to be free from

More information

TCIT Media. User Manual. Windows Version 1.0(b) Prepared on 4/29/2014

TCIT Media. User Manual. Windows Version 1.0(b) Prepared on 4/29/2014 TCIT Media Windows Version 1.0(b) Prepared on 4/29/2014 User Manual Trademarks TCIT and TCIT logo are registered trademarks of Taiwan Colour & Imaging Technology Corporation. Microsoft product names such

More information

A803 INSTRUCTION MANUAL

A803 INSTRUCTION MANUAL A803 INSTRUCTION MANUAL A803 Manual Rev C, 2/2014 Page 1 10 Technology Drive Peabody, MA 01960 Ph: 978-818-6180 Fax: 978-818-6181 Web: www.intl-lighttech.com 2011 International Light Technologies For most

More information

Tisio CE Release Notes

Tisio CE Release Notes Tisio CE Release Notes Copyright Copyright 2005, 2006, 2007 and 2008 by ThinPATH Systems, Inc. The information contained in this document is subject to change without notice. ThinPATH Systems, Inc. shall

More information

Drive Side. Host Side. Power. USB Mode Switch

Drive Side. Host Side. Power. USB Mode Switch Table of Contents 1. Pre-Installation Steps 2 1.1 Box Contents 2 1.2 Identifying Parts 2 2. Setup 3 3. Menu Structure/Usage 3 3.1 Select Mode 3 3.2 View Drive Info 3 3.3 View Dock Info 4 3.4 HPA/DCO Auto

More information

Digital MP3 & Video Player

Digital MP3 & Video Player Models 215/415/418/818 Digital MP3 & Video Player Table of Contents: Product Overview... 2 Features & Notes... 2 Charging...2 Button Overview.. 3 Button Descriptions....3 Mini SD Card...3 Loading music,

More information

i-disk Shield 2.0 Secure AES Manager User s Manual

i-disk Shield 2.0 Secure AES Manager User s Manual Secure AES Manager User s Manual (Version 2.0) PSAMUM_V2.0_2010/4/21-1 - www.pretec.com Table of Contents A. Introduction...4 B. General Description...4 C. Features...5 D. Before Using Secure AES Manager...6

More information

Remote Display User Manual

Remote Display User Manual Remote Display User Manual 1 Contents: Introduction - Features... 3 Hardware Overview... 4 Quick-Start Guide... 5 Android Application Operation... 6 Launching and Connecting... 6 Main Display... 7 Configuring

More information

Panaboard Overlayer User's Guide. Image Capture Software for Electronic Whiteboard (Panaboard)

Panaboard Overlayer User's Guide. Image Capture Software for Electronic Whiteboard (Panaboard) Panaboard Overlayer User's Guide Image Capture Software for Electronic Whiteboard (Panaboard) Contents Introduction... 3 Functional Overview... 3 Operation Flow... 3 Abbreviations... 4 Trademarks... 4

More information

The BuzzBox User Manual Revised June 2006

The BuzzBox User Manual Revised June 2006 The BuzzBox User Manual Revised June 2006 FCC Regulations Compliance (for USA) This equipment has been tested and found to comply with the limits for Class B digital device pursuant to Part 15 of FCC Rules.

More information

SensView User Guide. Version 1.0 February 8, Copyright 2010 SENSR LLC. All Rights Reserved. R V1.0

SensView User Guide. Version 1.0 February 8, Copyright 2010 SENSR LLC. All Rights Reserved. R V1.0 SensView User Guide Version 1.0 February 8, 2010 Copyright 2010 SENSR LLC. All Rights Reserved. R001-419-V1.0 TABLE OF CONTENTS 1 PREAMBLE 3 1.1 Software License Agreement 3 2 INSTALLING SENSVIEW 5 2.1

More information

QPP Proprietary Profile Guide

QPP Proprietary Profile Guide Rev. 04 April 2018 Application note Document information Info Content Keywords Proprietary Profile, Server, Client Abstract The Proprietary Profile is used to transfer the raw data between BLE devices.

More information

STYLE 6046 AKRO VIEW DIAGNOSTIC SOFTWARE INSTALLATION AND OPERATIONS MANUAL

STYLE 6046 AKRO VIEW DIAGNOSTIC SOFTWARE INSTALLATION AND OPERATIONS MANUAL STYLE 6046 AKRO VIEW DIAGNOSTIC SOFTWARE INSTALLATION AND OPERATIONS MANUAL 123064 Contents Introduction...3 Software Installation...4 USB to CAN Adapter Installation...7 Windows XP... 7 Windows Vista

More information

Technical Support 1600 N. Lorraine

Technical Support 1600 N. Lorraine Technical Support 1600 N. Lorraine 1-800-283-7543 Hutchinson, KS www.pdsmed.com PDS Cortex/Pervasive Version 9 Configuration and Troubleshooting Revised 8-22-2007 Disclaimer: Professional Data Services

More information

User Manual. ipad 360 Keyboard Case. For more support, please us at Your questions will be answered promptly.

User Manual. ipad 360 Keyboard Case. For more support, please  us at Your questions will be answered promptly. User Manual ipad 360 Keyboard Case For more support, please email us at cs@yekbee.com Your questions will be answered promptly. 1 Overview Charging light Battery light Pairing light Function keys Up key

More information

RS-1260 Digital Signage Player

RS-1260 Digital Signage Player RS-1260 Digital Signage Player User Manual V1.3 Legal Notice and Disclaimer Thank you for choosing RapidSignage products. This user manual provides a description of the Player relevant guidelines for key

More information

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide MULTIFUNCTIONAL DIGITAL SYSTEMS Software Installation Guide 2013 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced in any form without prior written

More information

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter

Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter Instructions for Installing FlashUpdate and Downloading Updates for Super Buddy Satellite Meter Updates to the Field Guide and to the instrument firmware are available from the Applied Instruments website.

More information

Instruction Manual. HH610-SW Application Software for Portable & Bench Meters

Instruction Manual. HH610-SW Application Software for Portable & Bench Meters Instruction Manual HH610-SW Application Software for Portable & Bench Meters Dear Customer, Thank you for choosing an Omega product. Please read this instruction manual carefully before using the software.

More information

USB-C to DVI Multiport Adapter with Power Delivery. Model

USB-C to DVI Multiport Adapter with Power Delivery. Model USB-C to DVI Multiport Adapter with Power Delivery Model 201049 Check for Thunderbolt 3 driver information at http://kb.cablematters.com User Manual email: support@cablematters.com Table of Contents 1.

More information

ImageMate 12-in-1 Reader/Writer User Guide

ImageMate 12-in-1 Reader/Writer User Guide ImageMate 12-in-1 Reader/Writer User Guide Model Number SDDR-89 Product Description The Multi-Function Hi-Speed USB 2.0 Reader/Writer CompactFlash Type I/II, SD TM, minisd TM, MultiMediaCard TM, RS-MMC

More information

Installation Guide. DVI Net ShareStation GDIP201 PART NO. M1048

Installation Guide. DVI Net ShareStation GDIP201 PART NO. M1048 Installation Guide DVI Net ShareStation 1 GDIP201 PART NO. M1048 2 Table of Contents Package Contents 4 Hardware Installation 5 USB Server software installation - XP 10 DisplayLink software installation

More information

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide

MULTIFUNCTIONAL DIGITAL SYSTEMS. Software Installation Guide MULTIFUNCTIONAL DIGITAL SYSTEMS Software Installation Guide 2013 TOSHIBA TEC CORPORATION All rights reserved Under the copyright laws, this manual cannot be reproduced in any form without prior written

More information

File Transfer Tool Guide Version 1.0. Revision History. Revision Date Page(s) Changed Description of Change 4/2009 All pages First edition released.

File Transfer Tool Guide Version 1.0. Revision History. Revision Date Page(s) Changed Description of Change 4/2009 All pages First edition released. 3M Digital Projector File Transfer Tool Guide Version 1.0 For Models: X62w / X64w / X90w / X95 Revision History Revision Date Page(s) Changed Description of Change 4/2009 All pages First edition released.

More information

GWU513 package contains: g USB Adapter 1 Quick Start Guide 1 Installation & Manual CD-ROM 1 Warranty/Registration Card

GWU513 package contains: g USB Adapter 1 Quick Start Guide 1 Installation & Manual CD-ROM 1 Warranty/Registration Card Wireless-G USB 2.0 Flex Adapter GWU513 Quick Start Guide Read this guide thoroughly and follow the installation and operation procedures carefully to prevent any damage to the unit and/or any of the devices

More information

MCS-TOUCHSCREEN Auto Disk Clean up

MCS-TOUCHSCREEN Auto Disk Clean up APP093 - MCS-Touchscreen Error 16 Auto Diskcleanup Procedure Micro Control Systems APPLICATION NOTE APP-093 MCS-TOUCHSCREEN Auto Disk Clean up Revision History Date Author Revision Description 07/31/2014

More information

National Instruments Analog-to-Digital (NI A2D) Module Manual

National Instruments Analog-to-Digital (NI A2D) Module Manual Particle Analysis and Display System (PADS): National Instruments Analog-to-Digital (NI A2D) Module Manual DOC-0292 Rev A PADS 3.5, NI A2D Module 3.5 2545 Central Avenue Boulder, CO 80301 USA C O P Y R

More information

Graphical User Interface V1.0.3

Graphical User Interface V1.0.3 Graphical User Interface V1.0.3 Application User Guide 2015 MCI Solutions. All rights reserved. 240815-01 www.mcisolutions.ca Page ii Getting Started Table Of Contents Introduction.................................................

More information

WIRELESS THIN-PROFILE KEYBOARD AND MOUSE USER S MANUAL.

WIRELESS THIN-PROFILE KEYBOARD AND MOUSE USER S MANUAL. WIRELESS THIN-PROFILE KEYBOARD AND MOUSE USER S MANUAL www.jascoproducts.com TABLE OF CONTENTS 1. INTRODUCTION...3 2. PACKAGE CONTENTS...3 3. SYSTEM REQUIREMENT...3 4. INSTALLATION INSTRUCTIONS...3 5.

More information

Table of Contents. Part I About Oxygen Software. Part II Introduction. Part III Data extraction. Part IV Settings. Part V Copyright notes.

Table of Contents. Part I About Oxygen Software. Part II Introduction. Part III Data extraction. Part IV Settings. Part V Copyright notes. Contents I Table of Contents Part I About Oxygen Software 2 Part II Introduction 2 Part III Data extraction 3 1 Call Data Records... 3 File import... 4 Field Mapping... 6 Conditions... 8 Results... 11

More information

This user guide describes how to run the Atmel ATWINC3400 Bluetooth Low Energy (BLE) Provisioning demo from out-of-box conditions.

This user guide describes how to run the Atmel ATWINC3400 Bluetooth Low Energy (BLE) Provisioning demo from out-of-box conditions. ATWINC3400 BLE ATWINC3400 BLE Provisioning - Setup and Usage USER GUIDE Introduction This user guide describes how to run the Atmel ATWINC3400 Bluetooth Low Energy (BLE) Provisioning demo from out-of-box

More information

User s Guide. Controller. Be sure to keep all user documentation handy for future reference.

User s Guide. Controller. Be sure to keep all user documentation handy for future reference. E User s Guide Controller Be sure to keep all user documentation handy for future reference. Read this first! The contents of this User s Guide are subject to change without notice. Copying of this manual,

More information

Smart Monitor ZG2 User s Manual

Smart Monitor ZG2 User s Manual Smart Monitor ZG2 User s Manual Smart Sensors ZG2 Series 2D Profile Measuring Sensors CONTENTS SMART MONITOR ZG2 USER S MANUAL...1 SECTION 1 PREPARATIONS...2 Installing the Smart Monitor ZG2 on a Computer...

More information

Thunderbolt 3 Multiport Adapter with Dual DisplayPort USB & Gigabit Ethernet. Model

Thunderbolt 3 Multiport Adapter with Dual DisplayPort USB & Gigabit Ethernet. Model Thunderbolt 3 Multiport Adapter with Dual 4K@60Hz DisplayPort USB & Gigabit Ethernet Model 107015 Check for Thunderbolt 3 driver information at http://kb.cablematters.com User Manual support@cablematters.com

More information

Thunderbolt 3 Multiport Adapter with Dual HDMI, USB & Gigabit Ethernet. Model

Thunderbolt 3 Multiport Adapter with Dual HDMI, USB & Gigabit Ethernet. Model Thunderbolt 3 Multiport Adapter with Dual 4K@60Hz HDMI, USB & Gigabit Ethernet Model 107016 Check for Thunderbolt 3 driver information at http://kb.cablematters.com User Manual support@cablematters.com

More information

with 975L IRROmesh Software Package Instructions

with 975L IRROmesh Software Package Instructions INSTALLATION AND OPERATING INSTRUCTIONS Logger Manual for Logger with Solar Panel & Battery Pack with 975L IRROmesh Software Package Instructions The IRROmesh Logger is intended for users who do not wish

More information

VZ-JSTK Keyboard User Manual

VZ-JSTK Keyboard User Manual VZ-JSTK Keyboard User Manual 0 User Manual About this Manual This Manual is applicable to VZ-JSTK Keyboard. The Manual includes instructions for using and managing the product. Pictures, charts, images

More information

14 Digital Photo Frame Instructional Manual

14 Digital Photo Frame Instructional Manual 14 Digital Photo Frame Instructional Manual aluratek.com mnl M10423 model ADMPF214B Copyright 2017 Aluratek, Inc. All Rights Reserved. Table of Contents Frame Features... Frame Control Close-up... Remote

More information

111 Highland Drive Putnam, CT USA PHONE (860) FAX (860) SM32Pro SDK

111 Highland Drive Putnam, CT USA PHONE (860) FAX (860) SM32Pro SDK SM32Pro SDK Spectrometer Operating Software USER MANUAL SM301/SM301EX Table Of Contents Warranty And Liability...3 Quick Start Installation Guide...4 System Requirements...5 Getting Started...6 Using the

More information

TRENDnet User s Guide. Cover Page

TRENDnet User s Guide. Cover Page Cover Page Table of Contents Contents Contents... i Product Overview... 1 Package Contents... 1 TEG-ECSX... 2 TEG-ECTX... 2 TEG-ECSFP... 2 Product Hardware Features... 3 System Requirements... 3 Installing

More information

Server Edition USER MANUAL. For Microsoft Windows

Server Edition USER MANUAL. For Microsoft Windows Server Edition USER MANUAL For Microsoft Windows Copyright Notice & Proprietary Information Redstor Limited, 2016. All rights reserved. Trademarks - Microsoft, Windows, Microsoft Windows, Microsoft Windows

More information

TI-73 / TI-83 Plus StudyCards Viewer

TI-73 / TI-83 Plus StudyCards Viewer ti TI-73 / TI-83 Plus StudyCards Viewer Getting Started Using the StudyCards Viewer How To View a Stack with Levels of Difficulty View a Multiple Choice Stack View a Self-check Stack Display Results Send

More information

GASLESS LEAK TRAINER

GASLESS LEAK TRAINER GASLESS LEAK TRAINER SUPPORTS SENSIT GOLD G2-GLT AND TRAK-IT IIIA GLT INSTRUCTION MANUAL 851 Transport Drive Valparaiso, IN 46383-8432 Phone: 888 473 6748 219 465 2700 Fax: 219 465 2701 Email: info@gasleaksensors.com

More information

AWLaunch. Software Manual. Version 1.2 Last Revised April 27, 2009

AWLaunch. Software Manual. Version 1.2 Last Revised April 27, 2009 AWLaunch Software Manual Version 1.2 Last Revised April 27, 2009 All contents in this manual are copyrighted by ArWest Communications. All rights reserved.the information contained herein may not be used,

More information

esoms Suite / Mobile Operator Rounds User Guide

esoms Suite / Mobile Operator Rounds User Guide esoms Suite / Mobile Operator Rounds User Guide Release 2.2 GMDDB-1008-1606-03 June 2016 Copyright 2016 ABB All Rights Reserved Confidential and Proprietary June 2016 Legal Disclaimer The product described

More information

x10data Application Platform v7.1 Installation Guide

x10data Application Platform v7.1 Installation Guide Copyright Copyright 2010 Automated Data Capture (ADC) Technologies, Incorporated. All rights reserved. Complying with all applicable copyright laws is the responsibility of the user. Without limiting the

More information

Multiplex Transmission Device. Support Tool. for master unit (XM-TBM32) of XM series conductor bar transmission units. Instruction Manual

Multiplex Transmission Device. Support Tool. for master unit (XM-TBM32) of XM series conductor bar transmission units. Instruction Manual Multiplex Transmission Device Support Tool for master unit (XM-TBM32) of XM series conductor bar transmission units Instruction Manual Contents 1. Operating environment... 2 1.1 Composition... 2 1.2 Connection...

More information

Server Edition. V8 Peregrine User Manual. for Microsoft Windows

Server Edition. V8 Peregrine User Manual. for Microsoft Windows Server Edition V8 Peregrine User Manual for Microsoft Windows Copyright Notice and Proprietary Information All rights reserved. Attix5, 2015 Trademarks - Microsoft, Windows, Microsoft Windows, Microsoft

More information

About this Guide. Cooper Security Ltd. 2012

About this Guide. Cooper Security Ltd. 2012 Cooper Security Ltd. 2012 IN NO EVENT WILL COOPER BE LIABLE FOR ANY SPECIAL, CONSEQUENTIAL, OR INDIRECT LOSS OR DAMAGE, INCIDENTAL DAMAGES, STATUTORY DAMAGES, EXEMPLARY DAMAGES, LOSS OF PROFITS, LOSS OF

More information

Made in U.S.A. 1

Made in U.S.A.   1 Made in U.S.A. www.smartavi.com 1 1-800-AVI-2131 TABLE OF CONTENTS INTRODUCTION & FEATURES 2 Getting Started and Installation 3 Start-Up 4 Managing Streams and Environment 5 Frequently Asked Questions

More information

Essen1e Application for the TI.83 Plus End Users Guide

Essen1e Application for the TI.83 Plus End Users Guide Essen1e Application for the TI.83 Plus End Users Guide Table of Contents Installation Instructions... 4 Using a PC to Install the Application to Your TI-83 Plus... 4 Using a MacintoshÐ to Install the Application

More information

Mobile Client Capability Brief for Exporting Mail in Microsoft* Office* Outlook* 2007

Mobile Client Capability Brief for Exporting Mail in Microsoft* Office* Outlook* 2007 Mobile Client Capability Brief for Exporting Mail in Microsoft* Office* Outlook* 2007 http://www.intel.com/performance/resources Version 2008-07 Rev. 1.0 Performance tests and ratings are measured using

More information