1 U41805-J-Z /C122-E087-03EN PRIMEQUEST 500A/500 SERIES Microsoft Windows Server 2008 USER'S GUIDE

2 Preface Purpose This manual explains the preparations and procedures for installing Windows Server 2008 on the PRIMEQUEST server and provides notes on operation and maintenance. Intended Readers This manual is intended for system administrators. High-risk Use of This Product This product is designed and manufactured for use in standard applications such as office work, personal device, household appliance, and general industrial applications. This product is not intended for use in nuclear-reactor control systems, aeronautical and space systems, air traffic control systems, mass transportation control systems, medical devices for life support, missile launch control systems or other specialized uses in which extremely high levels of reliability are required, the required levels of safety cannot be guaranteed, or a failure or operational error could be life-threatening or could cause physical injury (referred to hereafter as "high-risk" use). You shall not use this product without securing the sufficient safety required for high-risk use. If you wish to use this product for high-risk use, please consult with sales representatives in charge before such use. U41805-J-Z /C122-E087-03EN 2

3 Organization This manual is organized as follows. Chapter title Chapter 1 Overview of Windows Server 2008 Chapter 2 System Design Chapter 3 Installation Chapter 4 Environment Setting Chapter 5 Maintenance/Operation Appendix A Bundled Software Description Describes the functions and operating environment of Windows Server Provides notes on the system design for Windows Server Explains preparations for installing Windows Server 2008 and the installation procedure. Explains the environment settings that must be made before the start of operation. Provides notes on maintenance and operation. Describes the standard software bundle for the PRIMEQUEST server. How to Read This Manual If you are reading this manual for the first time, be sure to start from Chapter 1. Before installing Windows Server 2008, read Chapters 2 and 3. After installing Windows Server 2008 and before starting operation, read Chapters 4 and 5. Read Appendix A for the parts of the standard software bundle that you are going to use on the PRIMEQUEST server. Other Reference Manuals Referring to the following manuals, confirm the PRIMEQUEST hardware configuration and operation methods before reading this manual: PRIMEQUEST 580A/540A/580/540/480/440 System Design Guide (U41630-J-Z816-x-76/C122-B001EN) PRIMEQUEST 520A/520/420 System Design Guide (U41643-J-Z816-x-76/C122-B009EN) U41805-J-Z /C122-E087-03EN 3

4 PRIMEQUEST 510A System Design Guide (U41643-J-Z816-x-76/C122-B018EN)* PRIMEQUEST 500A/500/400 Series Installation Manual (U41632-J-Z816-x-76/C122-E001EN) PRIMEQUEST 580A/540A/520A/500/400 Series Reference Manual: Basic Operation/GUI/Commands (U41633-J-Z816-x-76/C122-E003EN) PRIMEQUEST 510A Reference Manual: Basic Operation/GUI/Commands (C122-E096EN)* PRIMEQUEST 500A/500/400 Series Reference Manual: Tools/Operation Information (U41757-J-Z816-x-76/C122-E074EN) PRIMEQUEST 580A/540A Dynamic Partitioning (DP) Manual (U41799-J-Z816-x-76/C122-E085EN) Notational Conventions Text Conventions Fonts/symbols Meaning Example Italic Indicates names of manuals. See the PRIMEQUEST 500A/500/400 Series Installation Manual (U41632-J-Z816-x-76/C122-E001EN). " " Indicates names of chapters and See "Chapter 3 Installation". sections. [ ] Indicates window names, window button names, tab names, and dropdown menu selections. Click the [OK] button. Syntax of the Command Line Interface (CLI) The command syntax is described below. A variable that requires input of a value must be enclosed in < >. An optional element must be enclosed in [ ]. A group of options for an optional keyword must be enclosed in [ ] and delimited by. A group of options for a mandatory keyword must be enclosed in { } and delimited by. The command syntax or file path is shown in a frame such as this one. *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 4

5 Product Names and Abbreviations In this manual, the product names are abbreviated as follows. Long title Abbreviations Microsoft Windows XP Professional Windows XP Microsoft Windows XP Home Edition Microsoft Windows Vista Business Windows Vista Microsoft Windows Vista Enterprise Microsoft Windows Server 2003 (*) Windows Server 2003 Microsoft Windows Server 2003, Enterprise Edition for Itanium-based Windows Server 2003 (IA64) Systems Microsoft Windows Server 2003, Datacenter Edition for Itanium-based Systems Microsoft Windows Server 2008 (*) Windows Server 2008 Microsoft Windows Server 2008 for Itanium-Based Systems Windows Server 2008 (IA64) * This is used when no platform is specified. Trademark Acknowledgements Microsoft, Windows, Windows Vista, and Windows Server are trademarks or registered trademarks of Microsoft Corporation in the United States and other countries. All other product names mentioned herein are the trademarks or registered trademarks of their respective owners. All other products are the property of their respective owners. Fujitsu has obtained permission from Microsoft Corporation to use figures showing the relevant windows and other GUI components. All Rights Reserved, Copyright FUJITSU LIMITED U41805-J-Z /C122-E087-03EN 5

6 Revision History Publisher: Fujitsu Limited and Fujitsu Technology Solutions 3rd edition: January 2009 (1/1) Edition Date Revised section Details /06/ /10/31 Chapter 4 Correction of descriptions about management LAN firewall settings. Addition of descriptions about Windows license activation /01/31 Chapter 4 Chapter 5 Addition of note about installing PSHED plugin driver. Addition of event log information. Fujitsu Technology Solutions - adds its order numbers to the manual and to manual references, - adds footnotes concerning the PRIMEQUEST models and Fujitsu software products which are not supported by Fujitsu Technology Solutions, - and substitutes a Fujitsu Technology Solutions web address for a Fujitsu web address. U41805-J-Z /C122-E087-03EN 6

7 Contents Preface... 2 Purpose... 2 Intended Readers... 2 High-risk Use of This Product... 2 Organization... 3 How to Read This Manual... 3 Other Reference Manuals... 3 Notational Conventions... 4 Trademark Acknowledgements... 5 Revision History... 6 Contents... 7 Chapter 1 Overview of Windows Server Features Supporting Models Chapter 2 System Design Notes on Using the DP Function I/O Units That Can Be Used Supported storage units Supported PCI cards Mounting conditions of PCI cards and usable built-in I/Os Notes on the PCI address mode (PRIMEQUEST 580A/540A/580/540) Notes on the display monitor resolution Clustering Configuration Range for recovery of a Windows cluster System construction Chapter 3 Installation Installation Flow Preparation for Installation Preparing the required items Building a SAN boot environment Connecting the MMB and making settings Making a single-path configuration and removing internal disks Windows Installation Using SystemcastWizard Lite U41805-J-Z /C122-E087-03EN 7

8 3.4 Manual Installation of Windows Required items Installation flow Switching the KVM/DVD-ROM drive Installing Windows Post-installation Work Installing the High-reliability Tools Connecting internal disks Installing the multipath driver...41 Chapter 4 Environment Settings PSA Settings Management LAN settings Installing the PSHED plug-in driver Setting a trap destination Setting a trap destination and mail destination via the MMB Making Windows Firewall settings Setting Watchdog monitoring for a period after a STOP error occurrence Setting Up the Memory Dump Environment Memory dump Paging file Configuring the Network Activating Windows NTP Client Settings NTP operation method for the PRIMEQUEST server NTP server settings NTP client settings of each partition Saving Setting Information Chapter 5 Maintenance/Operation System Startup and Shutdown Starting the system Shutting down the system Shutdown after logon to Windows Shutdown with the shutdown command Backup and Restore Backup/Restore using SystemcastWizard Lite Backup/restore using Windows Server Backup U41805-J-Z /C122-E087-03EN 8

9 5.3 Management LAN Reconfiguration Required When the BMM Is Replaced (PRIMEQUEST 580A/540A/580/540) Obtaining Maintenance Data Software Support Guide / DSNAP Memory dump User Mode Process Dumper and Desktop Heap Monitor Event Log List Method of checking an event log Event log list Appendix A Bundled Software A.1 Types of Software in the Bundled Software A.2 PSA A.2.1 Messages A.2.2 Notes A.3 DSNAP A.4 Software Support Guide A.5 SystemcastWizard Lite U41805-J-Z /C122-E087-03EN 9

10 Chapter 1 Overview of Windows Server 2008 This chapter describes the functions and operating environment of Windows Server Features Windows Server 2008 is a next-generation operating system with enhanced functionality and improved reliability built upon the features of the preceding Windows Server families to enable easier server management and security control. With Windows Server 2008 running on it, the PRIMEQUEST server becomes a platform that has the manageability, robustness, and flexibility of a mission-critical system. PRIMEQUEST supports Microsoft Windows Server 2008 for Itanium-Based Systems (*). (*) The edition is not included in notations in this manual. Enterprise and Datacenter are not distinguished in Itanium-based systems. Management enhancements Dispersed information and tools can now be referenced and manipulated with Server Manager. Moreover, not only have the standard built-in management commands been improved but also the possible range of management through CUI operations has been expanded. Some operations that require the same steps to be repeated many times manually in a GUI can easily be automated in a CUI. Note: The Server Core Installation Option cannot be selected for Windows Server 2008 (IA64). Security improvements For each executed operation or function that has an influence on the entire system, User Account Control (UAC) displays a dialog box to ask for confirmation that execution is permitted. This prevents damage from the abuse of system administrator privileges. Furthermore, Windows Firewall has been improved compared with Windows Server U41805-J-Z /C122-E087-03EN 10

11 Dynamic Partitioning function (PRIMEQUEST 580A/540A*) In the past, to replace or add a system board (SB) that has mounted CPUs or memory, the system must be stopped. The Dynamic Partitioning (DP) function developed by Fujitsu in cooperation with Microsoft has been implemented in Windows Server With this function, an SB can be replaced or added in the PRIMEQUEST 580A/540A* (**) without rebooting the system. (**) This function, which requires measures be taken on the hardware level, is supported by the PRIMEQUEST 580A/540A* and later models. 1.2 Supporting Models The following models in the PRIMEQUEST series support Windows Server 2008: PRIMEQUEST 580A/580 PRIMEQUEST 540A*/540 PRIMEQUEST 520A*/520 PRIMEQUEST 510A* *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 11

12 Chapter 2 System Design The basic system design policy does not have any major changes from Windows Server For details on the system design, see the following system design guides: PRIMEQUEST 580A/540A/580/540/480/440 System Design Guide (U41630-J-Z816-x-76/C122-B001EN) PRIMEQUEST 520A/520/420 System Design Guide (U41643-J-Z816-x-76/C122-B009EN) PRIMEQUEST 510A System Design Guide (C122-B018EN)* This chapter explains the requirements and necessary considerations for the system design for Windows Server 2008, and it provides notes on the system design. 2.1 Notes on Using the DP Function The system board (SB) configuration must be taken into account in use of the DP function. For details on design, see the PRIMEQUEST 580A/540A Dynamic Partitioning (DP) Manual (U41799-J-Z816-x-76/C122-E085EN). 2.2 I/O Units That Can Be Used Supported storage units The PRIMEQUEST/Windows system has a SAN boot environment that uses disk array units through Fibre Channel connections, and the use of such storage units as ETERNUS* systems is recommended. The explanations of procedures in this manual assume that ETERNUS* storage units are used Supported PCI cards For details on supported PCI cards, see the following manuals: Section 2.3.4, "Compatible PCI card", in the PRIMEQUEST 580A/540A/580/540/480/440 System Design Guide (U41630-J-Z816-x-76/C122-B001EN) Section 2.3.4, "Compatible PCI card", in the PRIMEQUEST 520A/520/420 System Design Guide (U41643-J-Z816-x-76/C122-B009EN) Section 2.3.4, "Compatible PCI card", in the PRIMEQUEST 510A System Design Guide (C122-B018EN)* *: supply and support in EMEA for Fujitsu s global accounts only U41805-J-Z /C122-E087-03EN 12

13 2.2.3 Mounting conditions of PCI cards and usable built-in I/Os For details on the mounting conditions of PCI cards and usable built-in I/Os, see the following manuals: Section 2.3.5, "Mounting conditions of PCI cards and usable built-in I/Os", in the PRIMEQUEST 580A/540A/580/540/480/440 System Design Guide (U41630-J-Z816-x-76/C122-B001EN) Section 2.3.5, "Mounting conditions of PCI cards and usable built-in I/Os", in the PRIMEQUEST 520A/520/420 System Design Guide (U41643-J-Z816-x-76/C122-B009EN) Section 2.3.5, "Mounting conditions of PCI cards and usable built-in I/Os", in the PRIMEQUEST 510A System Design Guide (C122-B018EN)* Notes If Windows Server 2008 installation is performed in an environment where an FC card is connected to PCI Express Slot#1 or Slot#3 in an I/O Unit or Slot#1 in a PEXU connected to the PRIMEQUEST 520A*/520, installation fails. To install Windows Server 2008, disconnect the FC card, or connect it to Slot#0 or Slot#2. After installation, there is no problem in using Slot#1 or Slot#3. The following Web site provides the latest released information on mounting conditions in detail (firmware version, driver version, etc.): (select Mission Critical IA Server as product) Notes on the PCI address mode (PRIMEQUEST 580A/540A*/580/540) Fujitsu recommend PCI address mode to be set to PCI Segment Mode. If the PCI address mode is changed after Windows installation, Windows may not start up. Determine the PCI address mode when designing the system, and do not change it after installing Windows. For the procedure for setting the PCI address mode and related details, see the following manual: Section 2.6.8, "Setting various modes", in the PRIMEQUEST 500A/500/400 Series Installation Manual (U41632-J-Z816-x-76/C122-E001EN) *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 13

14 2.2.5 Notes on the display monitor resolution No driver that supports Windows Server 2008 is provided for the PRIMEQUEST video controller. Therefore, the display monitor connected to the PRIMEQUEST server has only one resolution, 640 x 480 (VGA). However, a high-resolution display can be used for a remote desktop, and Fujitsu recommends using a remote desktop connection for system management. Prepare a management console PC that can be used with a remote desktop connection. U41805-J-Z /C122-E087-03EN 14

15 2.3 Clustering PRIMEQUEST supports failover clustering (WSFC), which is a standard function of Windows Server A server that is a component of a cluster is called a node. If each node is a PRIMEQUEST server with Windows running on it, the most basic cluster system has a configuration of two nodes using shared disks. If Windows Server 2008 is running on each node, a cluster system consisting of up to eight nodes can be constructed. There are two types of cluster configuration with the PRIMEQUEST server: an inter-cabinet cluster whose configuration is spread across cabinets, and an intra-cabinet cluster whose configuration consists of partitions within one cabinet. Remarks To configure WSFC, a separate Active Directory environment is required. To configure a cluster system that does not have the basic cluster configuration (two-node configuration with shared disks), contact your a certified service engineer. SB Cabinet SB Cabinet Crossbar Crossbar IOU PCI Card IO Port HDD MMB#0 MMB#1 IOU PCI Card IO Port HDD MMB#0 MMB#1 GSWB/GTHB GSWB/GTHB GSWB/GTHB Domain controller SW SW Shared disk FC Management LAN Private LAN Public LAN Figure 2-1 Sample basic configuration for an inter-cabinet cluster U41805-J-Z /C122-E087-03EN 15

16 Cabinet Partition#1 Partition#2 SB SB Crossbar IOU PCI Card HDD IOU PCI Card HDD MMB#0 MMB#1 IO Port IO Port GSWB/GTHB* Domain controller SW SW Shared disk FC Management LAN Private LAN Public LAN Figure 2-2 Sample basic configuration for an intra-cabinet cluster Configuration Shared disks Data used for business operation is stored on individual shared disk units (ETERNUS*) so that any node can access the data. However, multiple nodes cannot access the same data simultaneously. Network configuration The nodes configuring a cluster are connected via a dedicated LAN used for communication by each node to monitor errors on the other node(s) and ensure data consistency among the nodes. This LAN is called a private network (private LAN). In contrast, the LAN used for business operation is called a public network (public LAN). Business applications Business applications are installed on all active and standby nodes. *: supply and support in EMEA for Fujitsu s global accounts only U41805-J-Z /C122-E087-03EN 16

17 2.3.2 Range for recovery of a Windows cluster The cluster can be recovered from faults in hardware components, such as a CPU, motherboard, and LAN card, and software errors, such as an application error. However, the cluster is not a fault tolerant (FT) system. In the event of business failover, business is suspended for a short period System construction A dedicated startup service is provided for construction of Active Directory (AD) systems and cluster systems. For details, contact a certified service engineer. U41805-J-Z /C122-E087-03EN 17

18 Chapter 3 Installation This chapter explains the procedures for installing Windows Server 2008 on the PRIMEQUEST server. The recommended configuration for Windows is a SAN boot configuration using SAN storage units (ETERNUS*). The explanations of procedures in this chapter assume that the SAN storage units used are ETERNUS units. Remarks Windows Server 2008 for Itanium-based Systems does not support the Server Core Installation Option. Upgrade installation from Windows Server 2003 cannot be performed. *: supply and support in EMEA for Fujitsu s global accounts only U41805-J-Z /C122-E087-03EN 18

19 3.1 Installation Flow The Windows Server 2008 installation flow is shown below. Preparation for installation ( 3.2) 1. Build SAN boot environment ( Appendix D in installation manual) 2. Connect MMB and make settings 3. Remove internal disks Installation using SystemcastWizard Lite ( 3.3) Manual installation ( 3.4) Settings after installation ( 3.5) 1. Install High-reliability Tools 2. Connect internal disks 3. Install multipath driver Figure 3-1 Installation flow The following two methods are available for installing Windows Server 2008 on the PRIMEQUEST server: Installation using SystemcastWizard Lite Manual installation (through operations using the display, keyboard, and mouse connected to the main unit) U41805-J-Z /C122-E087-03EN 19

20 Table 3-1 Comparison of installation methods Installation using Manual installation SystemcastWizard Lite Preparation of deployment server (*1) Required Not required Time required for installation (rough standard) (*2) About one hour One hour and a half or longer Application of drivers/necessary tools Automatic application Manual application Simultaneous installation in multiple partitions Possible Not possible *1 A deployment server is a server on which SystemcastWizard Lite is installed. The prepared deployment server must be separate from the PRIMEQUEST server. For details, see the PRIMEQUEST SystemcastWizard Lite User's Guide (C122-E010EN). *2 This is a rough standard time from the start of installation, after preparation for installation, until Windows is ready for operation. It does not include the preparation time and the post-installation work time. This value may vary depending on the hardware configuration. Though preparations must be made (build of a deployment server and registration of resources) for installation using SystemcastWizard Lite, the time taken for installation is shorter than the time taken for manual installation. Also, SystemcastWizard Lite can perform simultaneous installation in multiple partitions. Furthermore, drivers and necessary tools are automatically applied. In contrast, manual installation can be started immediately with the Windows Server 2008 Installation DVD-ROM disk and the PRIMEQUEST Drivers CD for Microsoft Windows Server However, the time taken for installation is slightly longer than the time taken for installation using SystemcastWizard Lite, and drivers and necessary tools must be installed manually after Windows installation. Furthermore, installation in multiple partitions within a cabinet must be performed partition by partition in manual installation because the DVD-ROM drive is occupied. Select the installation method appropriate to the environment. To perform installation in multiple partitions, the recommended method is installation using SystemcastWizard Lite. To perform installation in one partition, or if a deployment server cannot be prepared, the recommended method is manual installation. U41805-J-Z /C122-E087-03EN 20

21 3.2 Preparation for Installation Complete these steps before starting Windows installation. Always use these steps for preparation, regardless of the installation method Preparing the required items The following items must be prepared for installation of Windows on the PRIMEQUEST server: Installation using SystemcastWizard Lite Deployment server (server on which SystemcastWizard Lite is installed) Windows Server 2008 Installation DVD-ROM disk PRIMEQUEST Drivers CD for Microsoft Windows Server 2008 Manual installation Console (with the keyboard, display, and mouse (KVM) connected) Windows Server 2008 Installation DVD-ROM disk PRIMEQUEST Drivers CD for Microsoft Windows Server Building a SAN boot environment Build a SAN boot environment by following the steps below. For details on the steps, see "Appendix D Installation in the SAN Boot Environment", in the PRIMEQUEST 500A/500/400 Series Installation Manual (U41632-J-Z816-x-76/C122-E001EN). Design the SAN boot environment The reliability of the PRIMEQUEST server varies significantly depending on the ETERNUS* or Fibre Channel connections used. Make SAN boot settings on the PRIMEQUEST server Based on the environment design, make ETERNUS* settings and related settings on the PRIMEQUEST server. Appropriate settings must be made for the Fibre Channel EFI driver. Make ETERNUS*/Fibre Channel switch settings Based on the cable connection drawing created during environment design, make settings for the ETERNUS*/Fibre Channel switch and PRIMEQUEST server, connect cables to them, and make other necessary settings and adjustments. *: supply and support in EMEA for Fujitsu s global accounts only U41805-J-Z /C122-E087-03EN 21

22 Note: Before starting installation, initialize the LUNs of the disk that is the Windows installation destination. If the disk has data remaining from a previously installed operating system, installation may fail Connecting the MMB and making settings The MMB comes prepared with the test environment configured by a certified service engineer, and test programs have been run on it. Therefore, switch from the setting for the test environment to that for the business operation environment. The necessary work items include setting the MMB IP address for business operation and connecting cables. After connecting the MMB, use the MMB Web user interface (Web-UI) to register a user account, make security settings, set the time, and make other MMB settings. Connect the MMB and make settings by following the steps below. Connection environment settings Connection environment settings for business operation for business operation - Make connection environment settings for business operation since connections have been set for testing purposes only. Network settings for business Network settings for business operation operation - Make network settings and Web server settings for business operation since the existing settings are for testing purposes only. Various initial settings for MMB Various initial settings for MMB - Register a user account. - Set up a user account for your Fujitsu certified service engineer. - Set a system name. - Set the date and time. - Set up telnet. - Make VLAN settings for the management LAN hub. Figure 3-2 MMB connection and setting workflow U41805-J-Z /C122-E087-03EN 22

23 The following items must be determined in advance for MMB settings: IP address, host name, subnet mask, and gateway address IP address of the personal computer used as the MMB console User account PRIMEQUEST system name (also used as the SNMP system name) Environment in which the management VLAN operates For details on the steps, see "Chapter 2 Setup", in the PRIMEQUEST 500A/500/400 Series Installation Manual (U41632-J-Z816-x-76/C122-E001EN) Making a single-path configuration and removing internal disks Before starting installation of the operating system, remove the disks not used for installation. 1. On the [Power Control] page of the MMB Web-UI, confirm that "Power Off" is displayed for the target partition in the System Progress column. PRIMEQUEST 580A/540A*/520A*/580/540/520: [Partition] [Power Control] PRIMEQUEST 510A*: [System] [Power Control] *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 23

24 Figure 3-3 [Power Control] page (PRIMEQUEST 580A/580/540A*/540) Figure 3-4 [Power Control] page (PRIMEQUEST 520A*/520) *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 24

25 Figure 3-5 [Power Control] page (PRIMEQUEST 510A*) 2. In an FC multipath configuration, disconnect the cable(s) on one side to make it a single-path configuration. 3. Remove any connected SCSI/SAS disks. *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 25

26 3.3 Windows Installation Using SystemcastWizard Lite SystemcastWizard Lite is software that enables you to easily install an operating system via a network. Installation using SystemcastWizard Lite can be done more quickly than manual installation, and SystemcastWizard Lite can perform simultaneous installation in multiple partitions. Registration of Windows Server Installation 2008 DVD-ROM disk and Drivers CD-ROM disk Management LAN Remote installation Deployment server running SystemcastWizard Lite PRIMEQUEST Figure 3-6 Installation using SystemcastWizard Lite SystemcastWizard Lite V2.0 and later support Windows Server For details on the necessary equipment and how to use SystemcastWizard Lite, see the PRIMEQUEST SystemcastWizard Lite User's Guide (C122-E010EN). Before starting installation, perform the work described in "3.2 Preparation for Installation". During installation, the Windows product key must be entered in SystemcastWizard Lite. For the location of your product key, see "Table 3-2 Location of the product key". After installation, perform the work described in "3.5 Post-installation Work". U41805-J-Z /C122-E087-03EN 26

27 3.4 Manual Installation of Windows This section explains the procedures for manual installation of Windows. In contrast with the automated installation using SystemcastWizard Lite, which eliminates KVM operations during installation, ordinary installation using the KVM is called manual installation, in this manual Required items The following items are required: KVM (keyboard, display, and mouse connected to the main unit) Windows Server 2008 Installation DVD-ROM disk PRIMEQUEST Drivers CD for Microsoft Windows Server 2008 (Drivers CD-ROM) The explanations of the procedures in subsequent sections assume that installation has been completed and equipment has been connected as described in the procedures in the sections up to and including "3.2 Preparation for Installation" Installation flow Perform installation by following the procedure below. U41805-J-Z /C122-E087-03EN 27

28 Switch KVM/DVD-ROM drive Insert Windows DVD-ROM disk Turn on power to partition Install Windows Perform post-installation work Figure 3-7 Manual installation flow Switching the KVM/DVD-ROM drive If the PRIMEQUEST server has multiple partitions, switch the KVM and DVD-ROM drive connected to the cabinet to the target partition before starting these operations. If the server is the PRIMEQUEST 520A*/520, the switching is only for the DVD-ROM drive. If the server is the PRIMEQUEST 510A*, the switching is not required since it does not have partitions. Make the switch setting from the MMB. *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 28

29 PRIMEQUEST Partition Partition Partition : : KVM interface unit MMB KVM Management LAN Figure 3-8 KVM connection in the PRIMEQUEST 580A/540A*/580/540 PRIMEQUEST Independent KVM switch Partition Partition DVD-ROM drive MMB Management KVM Figure 3-9 KVM connection in the PRIMEQUEST 520A*/ Log in to the MMB Web-UI. For the MMB Web-UI login procedure, see "Section Login to and logout from the MMB Web-UI", in the PRIMEQUEST 500A/500/400 Series Installation Manual (U41632-J-Z816-x-76/C122-E001EN). 5. Display the following page: [Partition] [USB/Video/DVD Switch] (for the PRIMEQUEST 580A/540A*/580/540) [Partition] [DVD Switch] (for the PRIMEQUEST 520A*/520) *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 29

30 Figure 3-10 [USB/Video/DVD Switch] page (PRIMEQUEST 580A/540A*/580/540) Figure 3-11 [USB/Video/DVD Switch] page 6. Select the [USB], [Video], and [DVD] radio buttons of the partition that is the Windows installation destination, and click the [Apply] button. *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 30

31 3.4.4 Installing Windows 7. Click [Power Control] from the MMB Web-UI. PRIMEQUEST 580A/540A*/520A*/580/540/520: PRIMEQUEST 510A*: [Partition] [Power Control] [System] [Power Control] Formatiert: Nummerierung und Aufzählungszeichen Figure 3-12 [Power Control] page (PRIMEQUEST 580A/540A*/580/540) Figure 3-13 [Power Control] page (PRIMEQUEST 520A*/520) *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 31

32 Figure 3-14 [Power Control] page (PRIMEQUEST 510A*) 8. Select [Power On] for the partition that is the Windows installation destination, in the Power Control column. Remarks: If the power to the partition is already on, select [Reset]. Formatiert: Nummerierung und Aufzählungszeichen 9. Click the [Apply] button. The [EFI Boot Manager] screen is displayed on the display monitor connected to the KVM interface unit. EFI Boot Manager ver 1.xx [1.xx] Formatiert: Nummerierung und Aufzählungszeichen Please select a boot option EFI Shell [Built-in] DVD/Acpi(xxxxxxxx,x)/Pci(xx x)/usb(x, x)/usb(x, x) Network/Acpi(xxxxxxx,x)/Pci(xx x)/pci(x x)/mac(xxxxxxxxxxxx) Boot Option Maintenance Menu Setup Menu Use ^ and v to change option(s). Use Enter to select an option 10. Insert the Windows Server 2008 Installation DVD-ROM disk into the DVD-ROM drive of the KVM interface unit. 11. Select "DVD/Acpi", and press the [Enter] key to start booting from the DVD-ROM disk. When the following message is displayed, press any key: Press any key to boot from CD or DVD... Formatiert: Nummerierung und Aufzählungszeichen 12. The message shown below is displayed. The setup program takes about 10 minutes to start. Windows is loading files... Formatiert: Nummerierung und Aufzählungszeichen *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 32

33 13. The window for language settings is displayed. Select the settings suitable for your environment, and click [Next]. Formatiert: Nummerierung und Aufzählungszeichen Figure 3-15 Selection of a language 14. The Windows installation window is displayed. Click [Install Now]. Formatiert: Nummerierung und Aufzählungszeichen Figure 3-16 Windows installation 15. If the product key window is displayed, enter the product key. The location of your product key depends on how you procured the product. Formatiert: Nummerierung und Aufzählungszeichen U41805-J-Z /C122-E087-03EN 33

34 Table 3-2 Location of the product key Method by which Location of product key Windows was procured Volume license Access the site at the URL shown on the Microsoft Open License Order Confirmation sheet. Bundled with hardware CoA sticker affixed to the main unit, or CoA sticker provided as a component (*1) *1 If the CoA sticker is provided as a component, confirm the contents of the "Important Notice" included in the product package, and be sure to affix the sticker to the main unit. Note. In Windows Server 2008, two keys to "Product Key" and "Virtual Key" might have been described. that case, please enter the "Product Key". In 16. The [Please Read the License Terms] page is displayed. Read the contents carefully. To accept the terms, check the [I accept the license terms] check box, and click the [Next] button. Formatiert: Nummerierung und Aufzählungszeichen 17. The [Which Type of Installation Do You Want?] page is displayed. Click [Custom (Advanced)]. Formatiert: Nummerierung und Aufzählungszeichen Figure 3-17 Installation type 18. Load the FC driver. When the [Where Do You Want to Install Windows?] page is displayed, click [Load Driver] at the bottom of the window. Formatiert: Nummerierung und Aufzählungszeichen U41805-J-Z /C122-E087-03EN 34

35 Figure 3-18 Installation location 19. When the [Load Driver] dialog box is displayed, remove the Windows Server Installation 2008 DVD-ROM disk from the DVD-ROM drive, insert the Drivers CD-ROM disk, and click the [Browse] button. Formatiert: Nummerierung und Aufzählungszeichen Figure 3-19 [Load Driver] dialog box 20. The [Browse for Folder] dialog box is displayed. Select the following folder on the Drivers CD-ROM disk, and click the [OK] button: [DVD-ROM-drive]:\Drivers\FC\Emulex Formatiert: Nummerierung und Aufzählungszeichen U41805-J-Z /C122-E087-03EN 35

36 Figure 3-20 [Browse for Folder] dialog box 21. Confirm that the following is displayed, and click the [Next] button: Emulex LightPulse HBA-Storport Miniport Driver ([DVD-ROM drive]:\drivers\fc\emulex\oemsetup.inf) Formatiert: Nummerierung und Aufzählungszeichen 22. Remove the Drivers CD-ROM disk from the DVD-ROM drive, and insert the Windows Server 2008 Installation DVD-ROM disk. Formatiert: Nummerierung und Aufzählungszeichen 23. Select the installation destination disk. To create a partition, select [Drive Option] [New]. Formatiert: Nummerierung und Aufzählungszeichen Figure 3-21 Drive option U41805-J-Z /C122-E087-03EN 36

37 24. Windows installation begins. Wait until installation is completed. The installation process involves several reboots, but do not operate the console during installation. Formatiert: Nummerierung und Aufzählungszeichen 25. The screen prompting you to enter an administrator password is displayed when installation is completed. Specify the password. Formatiert: Nummerierung und Aufzählungszeichen 26. After Windows starts up, install the High-reliability Tools. For details, see "3.5.1 Installing the High-reliability Tools". Formatiert: Nummerierung und Aufzählungszeichen U41805-J-Z /C122-E087-03EN 37

38 3.5 Post-installation Work Installing the High-reliability Tools The Drivers CD-ROM contains drivers and tools for realizing stable operation. These drivers and tools are called the High-reliability Tools. The installation methods depends on the Windows installation method: For installation using SystemcastWizard Lite The High-reliability Tools are automatically installed. For manual installation PRIMEQUEST High-reliability Tools Installer must be run manually from the Drivers CD-ROM after Windows installation. PRIMEQUEST High-reliability Tools Installer automatically identifies the environment of the installation target and installs the necessary tools and drivers. In the case of manual installation, follow the procedure below. 1. Log on to Windows with a user account that has administrator privileges. 2. Insert the Drivers CD-ROM disk into the DVD-ROM drive. 3. Execute the following program: [DVD-ROM-drive]:\pqsetup.exe Remarks: Using a user account other than "Administrator" If the program is executed with a user account other than the built-in "Administrator" account, the dialog box shown in "Figure 3-22 User account control" is displayed. Confirm that "FUJITSU LIMITED" is displayed, and then click the [Continue] button. U41805-J-Z /C122-E087-03EN 38

39 Figure 3-22 User account control 4. PRIMEQUEST High-reliability Tools Installer starts, and a dialog box is displayed. Figure 3-23 [PRIMEQUEST Software Installer] dialog box displayed at startup 5. Confirm the information displayed under "Following software will be installed", and click the [Run] button. Installation of the High-reliability Tools and drivers begins. 6. When a message is displayed to indicate the completion of installation, click the [Exit] button. 7. Restart the system. Remarks Log files are created at the following locations: Results of software installation %systemroot%\system32\logfiles\pqsetup.log Results of driver installation %systemroot%\system32\logfiles\pqdad-yyyymmdd.log %systemroot%: Windows installation folder (usually, C:\Windows) yyyymmdd: Year/month/day of driver installation U41805-J-Z /C122-E087-03EN 39

40 High-reliability Tools list Table 3-3 Software programs installed by PRIMEQUEST Software Installer and their settings Software name / setting to be changed Tools PSA DSNAP Software Support Guide Drivers Intel LAN Driver Broadcom LAN Driver Neterion LAN Driver Emulex FC Driver LSI Logic SCSI Driver LSI Logic SAS Driver Driver management tools Intel PROSet Xframe Control Panel Emulex HBAnyware Broadcom Advanced Control Suite Setting Remote desktop setting Kernel memory dump setting PXH setting PEX setting USB setting Description PRIMEQUEST system management application Tool for collecting necessary information for support Tool for collecting necessary information for support Intel LAN driver On-board LAN driver Neterion LAN driver Fibre Channel card driver SCSI driver SAS driver Provides the Intel LAN adapter with a teaming function. Provides the Neterion LAN adapter with a teaming function. Enables LUN state monitoring, etc. using Fibre Channel. Provides the Broadcom On-board LAN adapter with a teaming function. Set the remote desktop to enable remote management. Set memory dump collection in preparation for any problems. Change the PXH setting. Change the PEX setting. Change the USB setting. U41805-J-Z /C122-E087-03EN 40

41 Notes on using PRIMEQUEST High-reliability Tools Installer The PSHED plug-in of PSA is not automatically installed. The plug-in is stored in the Not_installed folder on the desktop and must be installed manually. The installation procedure is explained in the next chapter, in Section "4.1.2 Installing the PSHED plug-in driver". Intel PROSet and Neterion Xframe Control Panel are not automatically installed. They are stored in the Not_installed folder on the desktop and must be installed manually. For the installation procedures, see the documents listed below. These following documents are stored in the Drivers\DOC folder on the Drivers CD-ROM: Intel PROSet installation procedure LAN Card Users Guide (C122-E008) Neterion Xframe Control Panel installation procedure 10Gigabit LAN card (PCI-X) Users Guide (C122-E081) If a target device (e.g., LAN card, Fibre Channel card) has not been mounted at the time of driver/tool installation, the corresponding driver and tools are not installed Connecting internal disks Any SCSI/SAS disks that were removed before the operating system was installed must be restored to their original locations. Shut down the system, and connect the SCSI/SAS disks Installing the multipath driver Multipath environment settings must be made after the operating system is set up in a single-path environment using an FC cable. Install the multipath driver, and make the multipath environment settings. Note Do not establish a multipath connection before installing the multipath driver. Doing so may destroy data. For details on multipath driver installation and multipath connections, see the ETERNUS Multipath Driver V2.0 User's Guide (Windows ). U41805-J-Z /C122-E087-03EN 41

42 Chapter 4 Environment Settings This chapter explains the environment settings that must be made before the start of operation. Administrator privileges are required in the procedures in this chapter. Table 4-1 Work types Work name Work description Required Reference work? PSA settings Install PSA, and make monitoring settings. Required 4.1 Dump environment Make dump environment settings. Required 4.2 settings Network settings Configure a network for on-board/optional cards. Optional 4.3 Windows activation Activate Windows Server Required 4.4 NTP client settings Specify an NTP client. Optional 4.5 Storage of setting information Save PSA setting information and EFI configuration information. Recommended PSA Settings As explained below, confirm settings for operation of PSA as follows: Required Confirming management LAN settings ( "4.1.1") Installing the PSHED plug-in driver ( "4.1.2") Only as necessary Setting a trap destination ( "4.1.3") Setting and confirming a trap destination and mail destination via the MMB ( "4.1.4") Making Windows Firewall settings ( "4.1.5") Setting Watchdog monitoring for a period after a STOP error (fatal system error) occurrence ( "4.1.6") U41805-J-Z /C122-E087-03EN 42

43 Remarks Use PRIMEQUEST Software Installer or SystemcastWizard Lite to install PSA. For details on installation using PRIMEQUEST Software Installer, see "3.5.1 Installing the High-reliability Tools". In Windows installation using SystemcastWizard Lite, PSA is automatically installed. For details on SystemcastWizard Lite, see the PRIMEQUEST SystemcastWizard Lite User's Guide (C122-E010EN). The necessary components for REMCS* functions on the operating system side are installed when PSA is installed. A certified service engineer will make REMCS* settings. Each of the following settings required for PSA operation are made automatically when PSA is installed: 1. Service settings PRIMEQUEST Server Agent PRIMEQUEST PEM Command Service PRIMEQUEST PSA Environment Control Service 2. Environment variable settings PATH variable The values used by PSA are added to the existing PATH variable. FJSVpsa_INSTALLPATH variable It is added as a new variable. 3. Port settings The TCP:24450 port is set for use by PSA. 4. SNMP security setting Security is set for the SNMP Service since PSA must receive SNMP packets from the MMB. Processing varies depending on the selection made on the [Security] tab in the [SNMP Service Properties] dialog box during PSA installation. "Accept SNMP packets from any host" is selected: No SNMP security setting is made. "Accept SNMP packets from these hosts" is selected: If the IP address of the MMB and localhost have not been set for SNMP security, localhost will be set. *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 43

44 Notes If the SNMP Service security setting of "Accept SNMP packets from any host" is changed to "Accept SNMP packets from these hosts" after PSA is installed, or if the IP address of the MMB is changed after PSA is installed, execute the SNMP security setting command (setsnmpsec). For details on the command, see the PRIMEQUEST 580A/540A/520A//500/400 Series Reference Manual: Basic Operation/GUI/Command (U41633-J-Z816-x-76/C122-E003EN) or the PRIMEQUEST 510A Reference Manual: Basic Operation/GUI/Command (C122-E096EN)*. When PSA is started for the first time after being installed, the error message "E_33077 PSA is Not Active. (01:0000)" may be displayed following an attempt to display the PSA page from the Web-UI. This is because collection of system sensor information takes more time when PSA is started for the first time. Wait several minutes, and then display the PSA page again. When changing the IP addresses of the MMB and management LAN on the partition side, be sure to restart PSA. Otherwise, a PSA page display error occurs in the MMB Web-UI, and errors detected by PSA cannot be reported. Note the following about Windows settings: Do not stop the Print Spooler Service, which is a Windows service. The operating system information collection function uses Windows Management Instrumentation (WMI) to collect configuration information. However, an error is reported to WMI when the Print Spooler Service is stopped, and then configuration information cannot be correctly collected. If a value less than (20 seconds) is the specified value of the registry shown below, a hang may occur at the operating system shutdown time. Make sure that the registry is set with a value of (20 seconds) or greater. HKEY_LOCAL_MACHINE\SYSTEM\CurrentControlSet\Control " WaitToKillServiceTimeout" (Type: REG_DWORD; default: 20000) (The wait time (ms) until the service exits at the shutdown time can be specified in the above registry.) The following message may be recorded in the event log at PSA startup, but this message does not represent an operational problem: "PM child process abnormal end [6:750] (tagt) 1:0x " FJSVpsa event ID 62 *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 44

45 4.1.1 Management LAN settings This section explains how to make management LAN settings. On the partition side, the network interface card (NIC) connected to the management LAN must be active since PSA and the MMB communicate with each other via the management LAN. Set an available IP address for TCP/IP (IPv4) and disable IPv6, because the management LAN does not support IPv6. Also in this procedure, redundancy settings for the network adapters of the management LAN of the PRIMEQUEST 580A/540A*/580/540 will be made using Intel PROSet Teaming. Remarks Intel PROSet must be installed in advance. Specify "VLAN Mode" for the VLAN setting of the management LAN hub of the MMB. Section , "Setting a VLAN in a management LAN hub", in the PRIMEQUEST 500A/500/400 Series Installation Manual (U41632-J-Z816-x-76/C122-E001EN) The spanning tree (STP) function of the switch connected to the MMB user port (management LAN) must be set to OFF. Disabling IPv6 for the management LAN (1) Select [Control Panel] [Network and Sharing Center] [Manage network connections]. (2) Select and right-click [Intel(R) PRO/100 VE Network Connection], and then select [Properties] from the menu. (3) Uncheck the [Internet Protocol Version 6 (TCP/IPv6)] check box, and click [OK]. (4) For the PRIMEQUEST 580A/540A*/580/540, follow the same procedure with [Intel(R) PRO/100 M Network Connection]. Redundant configuration setting procedure for the management LAN (PRIMEQUEST 580A/540A*/580/540) (1) Click the [Start] menu [Server Manager]. (2) In the [Server Manager] window, select [Diagnostics] [Device Manager]. (3) Expand [Network Adapters], and click [Intel(R) PRO/100 VE Network Connection]. *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 45

46 Figure 4-1 [Server Manager] (Device Manager) window (4) The [Properties] dialog box is displayed. Click the [Teaming] tab, select [Team with other adapters], and then click the [New Team] button. U41805-J-Z /C122-E087-03EN 46

47 Figure 4-2 [Teaming] tab (5) The [New Team Wizard] dialog box is displayed. Enter a team name (default: Team#0), and click the [Next] button. U41805-J-Z /C122-E087-03EN 47

48 Figure 4-3 [New Team Wizard] dialog box (6) The network adapters that can be teaming targets are listed. Check [Intel(R) PRO/100 VE Network Connection] and [Intel(R) PRO/100 M Network Connection], and click the [Next] button. Figure 4-4 Network adapter list U41805-J-Z /C122-E087-03EN 48

49 (7) Select "Adapter Fault Tolerance" in the list of team types, and click [Next]. Figure 4-5 Selection of a team type (8) When the following dialog box is displayed, click the [Finish] button to start teaming configuration processing. Figure 4-6 Dialog box displayed when you finish making selections U41805-J-Z /C122-E087-03EN 49

50 (9) A teaming device is created and the properties are displayed when teaming configuration processing is completed. Click the [Settings] tab, and confirm that the correct adapter is displayed. When the correct adapter is displayed, click the [OK] button to exit. If there is any error, click the [Delete Team] button to delete the teaming device, and repeat step 2 and the subsequent steps. Figure 4-7 Team#0 properties (10) The display returns to the [Intel(R) PRO/100 VE Network Connection Properties] dialog box. Click the [OK] button to exit, and close [Computer Management]. (11) Select [Control Panel] [Network and Sharing Center] [Manage network connections]. A list of networks is displayed. (12) Select and right-click the device whose device name is the specified team name (e.g., Team#0), and then select [Properties] from the menu. (13) Select [Internet Protocol Version 4 (TCP/IPv4)], and click the [Properties] button. When the [Internet Protocol Version 4 (TCP/IPv4)] dialog box is displayed, specify an IP address, subnet mask, default gateway, and other information. U41805-J-Z /C122-E087-03EN 50

51 (14) Uncheck the [Internet Protocol Version 6 (TCP/IPv6)] check box. After completing this setting, click the [OK] button. Figure 4-8 [Local Area Connection Properties] dialog box As a result of the operations described above, link monitoring of the adapter begins, and the management LAN is set in a redundant configuration. Lastly, restart the operating system to enable teaming Installing the PSHED plug-in driver The PSHED plug-in is required for extending the functions of the Windows Hardware Error Architecture (WHEA). This driver is not automatically installed and must be installed manually using the batch file (plugin_install.bat) stored in the Not_installed folder on the desktop. U41805-J-Z /C122-E087-03EN 51

52 Unless this driver is installed, the following functions do not work: Inhibiting output of a log to the Event Viewer (Windows Log: System) in the event of a correctable error Transition to the panic state in the event of the blue screen of death (BSoD) (MMB Web-UI: [Power Control] page - [System Progress]) Notes Do not execute the installation batch two or more times. (Whenever this batch is executed, PRIMEQUEST PSHED Plugin Drivers are installed.) If you wrongly execute the installation batch two or more times, the item [PRIMEQUEST PSHED Plugin Driver] is displayed several times in System devices of Device Manager. But there is no negative impact in the system. In this case, install it again after uninstalling all PRIMEQUEST PSHED Plugin drivers according to the following procedures. And then the system needs to be reboot. PRIMEQUEST PSHED Plugin driver uninstallation procedure (1) Record the number of the items [PRIMEQUEST PSHED Plugin Driver] on the System devices of Device Manager. (2) Execute the uninstallation batch for PSHED Plugin driver repeatedly for the recorded number of times. Folder for uninstallation batch for PSHED Plugin driver: [PSA installation folder]\opt\fjsvpsa\sh\plugin_uninstall.bat (Default. C:\ Program Files\fujitsu\FJSVpsa\opt\FJSVpsa\sh\plugin_uninstall.bat) (3) Restart the Operating System. (4) Confirm that the item [PRIMEQUEST PSHED Plugin Driver] is not displayed on System devices of Device Manager. (5) Execute the installation batch again according to the following PRIMEQUEST PSHED Plugin driver installation procedures. Installation procedure 1. Open the Not_installed\Plugin folder on the desktop, and double-click [plugin_install.bat]. 2. When the [Windows Security] dialog box is displayed, click [Install]. U41805-J-Z /C122-E087-03EN 52

53 Figure 4-9 [Windows Security] dialog box 3. Restart the operating system. This driver starts running after the restart of the operating system. 4. Confirm that the item [PRIMEQUEST PSHED Plugin Driver] is displayed on System devices of Device Manager. If it is not displayed, execute from procedure 1, again Setting a trap destination Set the SNMP trap destination. Notes SNMPv3 is not supported in Windows. Make this setting only as necessary. In partitions managed by system management software, this setting is required. The trap destination must be able to receive the standard trap of the SNMP Service, and applications for receiving traps and management software must be running there. 1. Click the [Start] menu [Administrative Tools] [Services]. 2. Double-click [SNMP Service] in the right pane. The [SNMP Service Properties] dialog box is displayed. 3. Click [Traps]. 4. Enter the community name that you want to set in [Community Name], and click [Add]. 5. Click [Add] Under "Trap Destination". 6. Enter the host name or IP address of the server that will receives traps (send destination), and click [Add]. Click [OK]. 7. Click [Operations] [Restart] from the menu bar to restart the SNMP Service. U41805-J-Z /C122-E087-03EN 53

54 Method for confirming the trap destination settings To confirm the trap destination settings, send the standard trap of the SNMP Service when the SNMP Service is restarted in step 7. The settings can be confirmed correct depending on whether this trap was received. Remarks Restart the SNMP Service by performing step 7 on the trap sending computer. In that operation, "ColdStart", which is the standard trap of the SNMP Service, is posted to the trap receiving application from the trap destination. For example, suppose that the trap destination is a Linux machine and the trap is received by snmptrapd; then, the following message is displayed, which confirms that traps can be correctly received: Aug 17 14:50:03 pq-server snmptrapd[2600]: :50:03 pq-server.fujitsu.com [ ] (via ) TRAP, SNMP v1, community public SNMPv2-SMI:: enterprises Cold Start Trap (0) Uptime: 0:00: Setting a trap destination and mail destination via the MMB Notes Make this setting only as necessary. In partitions managed by system management software, this setting is required. The MMB Web-UI is used to set a trap destination and mail destination via the MMB. For details on the trap destinations involving the MMB, see "Section System SNMP settings", in the PRIMEQUEST 500A/500/400 Series Installation Manual (U41632-J-Z816-x-76/C122-E001EN). For details on the mail destinations involving the MMB, see "Section SMTP settings", in the PRIMEQUEST 500A/500/400 Series Installation Manual (U41632-J-Z816-x-76/C122-E001EN). U41805-J-Z /C122-E087-03EN 54

55 4.1.5 Making Windows Firewall settings To enable Windows Firewall for operation, the following ports must be open so that they can be used to communicate with MMB: UDP:Port 161 used by SNMP Service [receive data from MMB] TCP:Port used by fjpsawg.exe [receive data from MMB] TCP port for sending used by fjpsammbs.exe [send data to MMB TCP:Port 5000] ICMP to MMB port used by fjpsammbs.exe The [Windows Firewall with Advanced Security] window is used to make Windows Firewall settings. (1) Click [Administrative Tools] [Windows Firewall with Advanced Security] from the [Start] menu. (2) The [Windows Firewall with Advanced Security] window is displayed. Click [Inbound Rules] in the left pane. The [Inbound Rules] pane is displayed in the center with a list in it. U41805-J-Z /C122-E087-03EN 55

56 Figure 4-10 Windows Firewall (3) Select and right-click [SNMP Service (UDP In)] in [Inbound Rules], and then select [Properties]. There are two rules named "SNMP Service (UDP In)": one has the Domain profile, and the other has the Private, Public profile. Follow steps (3) to (6) for every SNMP Service (UDP In) rule. (4) The [SNMP Service (UDP In) Properties] dialog box is displayed. Click the [General] tab, and check the [Enabled] check box in "General". (It is checked by default.) U41805-J-Z /C122-E087-03EN 56

57 Figure 4-11 SNMP Service (UDP In) Properties - General (5) Click the [Scope] tab. Select [Any IP address] in "Local IP address". Select [These IP addresses] in "Remote IP address", and click [Add]. U41805-J-Z /C122-E087-03EN 57

58 Figure 4-12 SNMP Service (UDP In) Properties - Scope (6) The [IP Address] dialog box is displayed. Select [Predefined set of computers:], and then select [Local subnet] from the list. Click [OK]. U41805-J-Z /C122-E087-03EN 58

59 Figure 4-13 IP Address (7) Click [OK] to close the [SNMP Service (UDP In) Properties] dialog box. (8) Click [New Rule ] in the right pane of the [Windows Firewall with Advanced Security] window. The [New Inbound Rule Wizard] dialog box is displayed, with "Rule Type" highlighted at the upper left. Select [Custom], and click [Next]. U41805-J-Z /C122-E087-03EN 59

60 Figure 4-14 New Inbound Rule Wizard - Rule Type (9) "Program" is highlighted at the upper left of the [New Inbound Rule Wizard] dialog box. Select [This program path], click [Browse ], and then select the fjpsawg.exe program. The fjpsawg.exe program is in the opt\fjsvpsa\bin\ folder in the PSA install path. The default PSA install path is C:\Program Files\fujitsu\FJSVpsa\. Next, click [Next]. U41805-J-Z /C122-E087-03EN 60

61 Figure 4-15 New Inbound Rule Wizard - Program (10) "Protocol and Ports" is highlighted at the upper left of the [New Inbound Rule Wizard] dialog box. Select [TCP] in the [Protocol type:] drop-down box. Select [Specific Ports] in the [Local port:] drop-down box, and enter "24450" in the text box under the [Local port:] drop-down box. Lastly, click [Next]. U41805-J-Z /C122-E087-03EN 61

62 Figure 4-16 New Inbound Rule Wizard - Protocol and Ports (11) "Scope" is highlighted at the upper left of the [New Inbound Rule Wizard] dialog box. Select [Any IP Address] under "Which local IP addresses does this rule match?" Select [These IP Addresses:] under "Which remote IP addresses does this rule match?" Click [Add ], and enter the logical IP address of the MMB. Click [Next]. U41805-J-Z /C122-E087-03EN 62

63 Figure 4-17 New Inbound Rule Wizard - Scope (12) "Action" is highlighted at the upper left of the [New Inbound Rule Wizard] dialog box. Select [Allow the connection], and click [Next]. U41805-J-Z /C122-E087-03EN 63

64 Figure 4-18 New Inbound Rule Wizard - Action (13) "Profile" is highlighted at the upper left of the [New Inbound Rule Wizard] dialog box. Check all check boxes ([Domain], [Private], and [Public]), and click [Next]. U41805-J-Z /C122-E087-03EN 64

65 Figure 4-19 New Inbound Rule Wizard - Profile (14) "Name" is highlighted at the upper left of the [New Inbound Rule Wizard] dialog box. Enter "PSAWG" in the [Name:] text box, and click [Finish]. U41805-J-Z /C122-E087-03EN 65

66 Figure 4-20 New Inbound Rule Wizard - Name (15) Click [Outbound Rules] in the left pane of the [Windows Firewall with Advanced Security] window. The [Outbound Rules] pane is displayed in the center. (16) Click [New Rule ] in the right pane of the [Windows Firewall with Advanced Security] window. The [New Outbound Rule Wizard] dialog box is displayed, with "Rule Type" highlighted at the upper left. Select [Custom], and click [Next]. (17) "Program" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Select [This program path], click [Browse ], and then select the fjpsammbs.exe program. The fjpsammbs.exe program is in the opt\fjsvpsa\bin\ folder in the PSA install path. The default PSA install path is C:\Program Files\fujitsu\FJSVpsa\. Next, click [Next]. (18) "Protocol and Ports" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Select [TCP] in the [Protocol type:] drop-down box. Select [All Ports] in the [Local port:] drop-down box. Select [Specific Ports] in the [Remote port:] drop-down box, and enter "5000" in the text box under the [Remote port:] drop-down box. Lastly, click [Next]. U41805-J-Z /C122-E087-03EN 66

67 Figure 4-21 New Outbound Rule Wizard - Protocol and Ports (19) "Scope" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Select [Any IP Address] under "Which local IP addresses does this rule match?" Select [These IP Addresses:] under "Which remote IP addresses does this rule match?" Click [Add...], and enter the logical IP address of the MMB. Click [Next]. (20) "Action" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Select [Allow the connection], and click [Next]. (21) "Profile" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Check all check boxes ([Domain], [Private], and [Public]), and click [Next]. (22) "Name" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Enter "PSAMMBS" in the [Name:] text box, and click [Finish]. (23) Click [New Rule ] again in the right pane of the [Windows Firewall with Advanced Security] window. The [New Outbound Rule Wizard] dialog box is displayed, with "Rule Type" highlighted at the upper left. Select [Custom], and click [Next]. U41805-J-Z /C122-E087-03EN 67

68 (24) "Program" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Select [This program path], click [Browse ], and then select the fjpsammbs.exe program. The fjpsammbs.exe program is in the opt\fjsvpsa\bin\ folder in the PSA install path. The default PSA install path is C:\Program Files\fujitsu\FJSVpsa\. Next, click [Next]. (25) "Protocol and Ports" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Select [ICMPv4] in the [Protocol type:] drop-down box, and click [Next]. Figure 4-22 New Outbound Rule Wizard - Protocol and Ports (26) "Scope" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Select [Any IP Address] under "Which local IP addresses does this rule match?" Select [These IP Addresses:] under "Which remote IP addresses does this rule match?" Click [Add...], and enter the logical IP address of the MMB. Click [Next]. (27) "Action" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Select [Allow the connection], and click [Next]. (28) "Profile" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Check all check boxes ([Domain], [Private], and [Public]), and click [Next]. (29) "Name" is highlighted at the upper left of the [New Outbound Rule Wizard] dialog box. Enter "PSAICMP" in the [Name:] text box, and click [Finish]. U41805-J-Z /C122-E087-03EN 68

69 4.1.6 Setting Watchdog monitoring for a period after a STOP error occurrence If a STOP error (fatal system error) occurs in the system, the system enters the following state: "Panic" is displayed for the relevant partition in the System Progress column on the [Partition] [Power Control] page of the MMB Web-UI. The operating system executes processing for memory dump collection. Monitoring can be set with Watchdog Timer as a measure for treating the system in a non-responsive state, such as a system freeze. Once the specified period elapses, the MMB performs a Hard Reset to reboot the operating system. Setting procedure Open the following file: [PSA-installation-folder] \etc\opt\fjsvpsa\usr\pnwatchdog.conf (Example: C:\fujitsu\FJSVpsa\etc\opt\FJSVpsa\usr\pnwatchdog.conf) Set a value for the key shown below. The default setting value is 0. Section: [WATCHDOG] Key: [TIMER] Setting value (unit: second): 0 (Watchdog Timer is not used.) 1 to 6000 (Watchdog Timer monitoring time) Remarks Determine an appropriate setting value for a partition by measuring the time taken for a memory dump in the partition. If the time taken for memory dump processing is longer than 6000 seconds (one hour and 40 minutes), do not use Watchdog Timer. If the setting value is shorter than the time taken for memory dump processing, a timeout occurs in Watchdog Timer, causing a Hard Reset and preventing memory dumps from being obtained correctly. U41805-J-Z /C122-E087-03EN 69

70 4.2 Setting Up the Memory Dump Environment You can use a standard function of Windows Server 2008 to collect a memory dump. When Windows detects a fatal problem, it automatically displays a STOP error (i.e., BSoD), creates a file (dump file), and outputs the contents of memory to the file. If a system hang or slowdown occurs, Windows can be forcibly instructed by the administrator as described below to collect a memory dump. To perform a memory dump, sufficient space for the memory dump must have been made available on the system disk. This section explains how to set up the environment for performing a memory dump in Windows Server For details on memory dump-related operations, see "Chapter 1 System Maintenance", in the PRIMEQUEST 500A/500/400 Series Reference Manual: Tools/Operation Information (U41757-J-Z816-x-76/C122-E074EN). According to the emphasis placed on investigation of the cause of system problem vs. quick system recovery after a system problem occurs, set up the memory environment as described in the following sections before starting business operation Memory dump The memory dump file stores debug information for a STOP error (fatal system error) that occurred in the system. After the operating system and applications used for business operation are installed, make settings for memory dump collection Differences in information that can be collected in a memory dump The three types of memory dump that can be set for the PRIMEQUEST server are described below, and each type of memory dump collects a different range of information. Before collecting a memory dump, confirm that the hard disk drive has sufficient free space. Complete memory dump The entire contents of physical memory in the boot volume are saved when the system is stopped. The size of the dump file is approximately the physical memory size plus 1 MB. Only one memory dump can be stored. If the specified storage destination has an existing dump file, the information in the file is overwritten. A minimum memory dump is collected at the same time. U41805-J-Z /C122-E087-03EN 70

71 Kernel memory dump The recorded information covers only the kernel memory areas. The size of the dump file depends on the memory usage conditions. As a rough standard, the size ranges from one gigabyte to several gigabytes (the theoretical maximum size is the size of mounted physical memory plus 128 MB). Only one memory dump can be stored. If the specified storage destination has an existing dump file, the information in the file is overwritten. A minimum memory dump is collected at the same time. Minimum memory dump Only the minimum necessary information is recorded. The required amount of free space is 64 KB or 128 KB. If this option is specified, a new file is created every time that the system stops unexpectedly. Normally, since it is sometimes difficult to solve a problem with a minimum memory dump, specify complete memory dump or kernel memory dump. For details on the memory dumps, see the following URL: Table 4-2 Memory dump types and dump file sizes Memory dump type Complete memory dump Kernel memory dump Minimum memory dump Memory dump file size Recording method Mounted physical memory size + 1 MB Overwrite (*2) Depends on memory space where operating Overwrite (*2) system is running Usually: About one to several gigabytes Maximum: Mounted physical memory size MB (*1) 64 KB or 128 KB In new file created *1 This is the maximum theoretical size. The actual size depends on the size of the kernel memory space. *2 The existing file is overwritten by default. You can set that the dump file not be overwritten. In such a case, however, note that no new file is created, unlike the case for a minimum memory dump. U41805-J-Z /C122-E087-03EN 71

72 Note When a dump file is generated, the boot volume (C:) must have sufficient free capacity. boot volume is used temporarily to preserve the dump file in advance. This is because the When you preserve the dump file in the boot volume: Please prepare twice of the size of the dump file empty capacity When you preserve the dump file besides the boot volume: Please prepare the same size as dump file empty capacity in both the boot volume and the dump file preservation ahead. Selecting a dump setting Consider the following about selecting the optimal setting for system operation: Kernel memory dump is set as the dump type when PRIMEQUEST Software Installer is run. The causes of most STOP errors are in drivers, and the causes can be roughly investigated with kernel dumps. However, in the case of a system hang or slowdown, such as in a business application, the processing state of a process in user mode is important, and the cause of the problem may be impossible to determine without a complete memory dump. For a complete memory dump, the time required in creating the dump increases in proportion to the mounted physical memory size, and as a result, the system stop time before the resumption of business operation is longer. Furthermore, more space on the disk drive is required for storing the dump file. Therefore, if the mounted physical memory size is at or near the maximum, it may be impractical to make available the necessary disk space for storing a complete memory dump. Moreover, consideration must be given to how to send the dump file since the size of a collected complete memory dump is huge. If priority is placed on investigating the cause of a problem, the recommended type is complete memory dump; and if priority is placed quicker recovery of business operation, the recommended type is kernel memory dump. Determine the optimal setting by considering an acceptable length of time that system operation is suspended, the customer's desired operation policy, and other factors. U41805-J-Z /C122-E087-03EN 72

73 Method of setting complete memory dump Complete memory dump cannot be set from the window for system dump settings. You can set it by changing the registry value as follows: HKEY_LOCAL_MACHINE\System\CurrentControlSet\Control\CrashControl "CrashDumpEnabled" (Type: REG_DWORD; data: 1 ) After making the setting, restart the system. The storage path and overwrite settings for the dump file are the same as for kernel memory dump. For details, see " Method of setting kernel memory dump" Method of setting kernel memory dump Set the memory dump file by following the procedure below. 1. Log on to the server with administrator privileges. 2. Confirm that there is sufficient free space on the drive storing the memory dump file. 3. Click [Server Manager] [Change System Properties]. The [System Properties] dialog box is displayed. 4. Click the [Advanced] tab, and then click [Settings] under "Startup and Recovery". The [Startup and Recovery] dialog box is displayed. U41805-J-Z /C122-E087-03EN 73

74 Figure 4-23 [Startup and Recovery] dialog box 5. Select the type of memory dump file for "Write debugging information". If complete memory dump has already been selected, the setting need not be changed. 6. Click [OK] to close the [Startup and Recovery] dialog box. 7. Click [OK] to close the [System Properties] dialog box. 8. Restart the partition. The setting becomes valid after the restart of the partition Confirming the memory dump settings Collect a dump to confirm that a dump file is created at the appropriate location in the specified path. Confirm that the dump file update date and time are also the dump collection date and time. In a complete memory dump, confirm that the size of the created dump file is the mounted memory size plus several megabytes. U41805-J-Z /C122-E087-03EN 74

75 In a kernel memory dump, confirm that the dump file size is not extraordinarily small (100 MB or less), though the size depends on the environment. Also, measure the actual time taken for outputting the dump, restarting the system, and executing other processing in this operation, and estimate the time taken until business operation resumes. Then, reconsider the memory dump type as necessary. To obtain a memory dump, specify "INIT" for the target partition on the [Partition] [Power Control] page of the MMB Web-UI. For details, see the following manuals: Chapter 5, "Web-UI Operations", in the PRIMEQUEST 500A/500/400 Series Reference Manual: Basic Operation/GUI/Command (U41633-J-Z816-x-76/C122-E003EN) Chapter 5, "Web-UI Operations", in the PRIMEQUEST 510A Reference Manual: Basic Operation/GUI/Command (C122-E096EN)* Paging file The paging file is ordinarily used to temporarily store data from memory on a hard disk drive, but it is sometimes also used for temporary storage of a collected memory dump. To ensure collection of a memory dump, confirm that the paging file settings are correct Making paging file settings Change the setting by following the procedure below. 1. Log on to the server with administrator privileges. 2. Click [Server Manager] [Change System Properties]. The [System Properties] dialog box is displayed. 3. Click the [Advanced] tab, and then click [Settings] under "Performance". The [Performance Options] dialog box is displayed. 4. Click the [Advanced] tab. *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 75

76 Figure 4-24 [Advanced] tab in the [Performance Options] dialog box 5. Click [Change] in "Virtual Memory". The [Virtual Memory] dialog box is displayed. U41805-J-Z /C122-E087-03EN 76

77 Figure 4-25 [Virtual Memory] dialog box 6. Uncheck the [Automatically manage paging file size for all drives] check box. 7. Specify the drive for the created paging file. Select the system installation drive from under "Drive". The selected drive is displayed next to "Selected drive" in "Paging file size for each drive". 8. Select [Custom size], and enter a value in [Initial size (MB)]. To determine the minimum value, you can use the following method: (1) Enter the value displayed next to "Minimum allowed" in "Total paging file size for all drives" in [Initial size (MB)] under [Custom size], and then enter the "Minimum allowed" value plus 2 MB in [Maximum size (MB)]. Click the [Set] button. For example, the following values are used in "Figure 4-25 [Virtual Memory] dialog box": Initial size (MB): 16 MB Maximum size (MB): 18 MB (2) Unless a message such as shown below is displayed, use these values for the settings. If such a message is displayed, use a value that is greater than the "Minimum allowed" value by at least 1 MB ( = 5844 MB or more, in this example). U41805-J-Z /C122-E087-03EN 77

78 Figure 4-26 Confirmation message dialog box 9. Enter an appropriate value in [Maximum size (MB)]. It must be greater than the value in [Initial size (MB)]. 10. Save the settings. Click [Set] in "Paging file size for each drive". The settings are saved, and the set values are displayed under "Paging File Size (MB)" for the drive displayed under "Drive". 11. Click [OK] to close the [Virtual Memory] dialog box. 12. Click [OK] to close the [Performance Options] dialog box. 13. Click [OK] to close the [System Properties] dialog box. 14. Restart the partition. Formatiert: Französisch (Frankreich) The setting becomes valid after the restart of the partition Notes If the paging file is placed in a volume that is not the boot volume (usually, the C: drive), a dump file is not created at the time that a STOP error or another error occurs. Unless there is a special reason to do so, do not move the paging file to any volume that is not the boot volume. U41805-J-Z /C122-E087-03EN 78

79 4.3 Configuring the Network Make teaming (multipath) settings by using the utility corresponding to each network adapter. PCI card network adapter (Intel GbE) settings You can configure teaming that uses Intel PROSet. For details, see the Help for Intel PROSet. To display the Help, expand the Intel_landl5.exe file in the Not_Installed\PROSet folder on the desktop, and open the index.html file in the browser. PCI card network adapter (Neterion 10GbE) settings You can configure teaming that uses Neterion Xframe Control Panel. For details, see the Help for Neterion Xframe Control Panel. To display the Help, select the [Start] menu [All Programs] [Xframe Network Services] [Xframe Help]. On-board network adapter (Broadcom GbE) settings You can configure teaming by using the Broadcom Advanced Server Program (BASP) in the Broadcom Advanced Control Suite 3 (BACS3) utility. For details, see "Chapter 8 Onboard GbE (Broadcom Ethernet) Network Configuration Under Windows Environment", in the PRIMEQUEST 500A/500/400 Series Reference Manual: Tools/Operation Information (U41757-J-Z816-x-76/C122-E074EN). U41805-J-Z /C122-E087-03EN 79

80 4.4 Activating Windows Windows Server 2008 must be activated before the start of operation. OEM (bundled with hardware) You can activate Windows via the Internet or by telephone. 1. Click [Start] [Control Panel] [System]. 2. Activate Windows by following the instructions in [Windows Activation] from the [System] screen. Volume license You can activate Windows by using Volume Activation 2.0. For details, see the following URL: U41805-J-Z /C122-E087-03EN 80

81 4.5 NTP Client Settings This section explains time correction operations with the network time protocol (NTP), particularly operation methods for the PRIMEQUEST server. NTP is a protocol defining the method used by computers to exchange time information with one other. NTP provides a function that sets the system clock time to the time of a reference clock that maintains accurate time and subsequently keeps any time differences within a certain range NTP operation method for the PRIMEQUEST server This section explains the time correction method using NTP in each partition of the PRIMEQUEST system. In a PRIMEQUEST server, the MMB provides the NTP client function and NTP server function. Up to three external NTP servers can be specified with the NTP client function. Each partition makes its own time corrections using the NTP server function of the MMB. Figure 4-27 outlines the operation with an external NTP server. PRIMEQUEST #2 Partition #2 PRIMEQUEST NTP#1 client Partition Partition #2 #1 NTP client NTPシステ client Partition Partition #1 #0 NTP client システム NTP client Partition #0 NTP システム client MMB NTP client MMB NTP NTP client GSWB NTP NTP client GSWB NTP client External NTP server #1 External NTP server #2 External NTP server #3 System Figure 4-27 Operation with an external NTP server U41805-J-Z /C122-E087-03EN 81

82 4.5.2 NTP server settings Make settings for any NTP servers not included in the initial settings of the MMB. Use the NTP client function to set the external NTP servers with which time is synchronized. Also, make the MMB available as an NTP server for other clients. 1. Click [Network Configuration] [Date/Time]. The [Data/Time] page is displayed. Figure 4-28 [Date/Time] page 2. Click [Enable] of [NTP]. 3. Enter the IP addresses of the external NTP servers. (1) NTP Server1: Specify the primary NTP server. (2) NTP Server2: Specify the secondary NTP server. (3) NTP Server3: Specify another (tertiary) NTP server. Remarks: If the MMB is not synchronized with any external NTP server, set " " for each of NTP Server1 to NTP Server3. The MMB serves as an NTP server for each partition, but the MMB itself is not synchronized with any external NTP server. 4. Click the [Apply] button. The time of the MMB is synchronized with the time of the NTP servers set for NTP Server1 to NTP Server3. Subsequently, other clients can use the MMB as an NTP server. 5. Wait several minutes, click [Refresh], and confirm that the correct time is displayed. U41805-J-Z /C122-E087-03EN 82

83 4.5.3 NTP client settings of each partition If the MMB is set as an NTP server, each partition serves as an NTP client Making NTP settings in a Windows partition This section explains the method of making NTP settings in a partition in which Windows is installed. 1. Log on to the system with a user account that has administrator privileges. 2. Click [Control Panel] [Date and Time]. The [Date and Time] dialog box is displayed. Figure 4-29 [Internet Time] tab 3. Click the [Internet Time] tab, and then click [Change Settings]. 4. Enter the virtual IP address of the MMB in the [Server:] box, and click [OK] to close the dialog box. 5. The [Internet Time] tab of the [Date and Time] dialog box is displayed again. Click [Update Now]. Following correct communication with the NTP, the message "The clock was successfully synchronized" is displayed as shown in "Figure 4-30 MMB virtual IP address setting example". U41805-J-Z /C122-E087-03EN 83

84 Figure 4-30 MMB virtual IP address setting example Notes: 1. If the [Automatically synchronize with an Internet time server] check box is checked, the clock is automatically synchronized with the specified server. 2. By default, "time.windows.com" is specified in the [Server:] box. 3. If the clock cannot be synchronized with the NTP server, the "Time-Service" warning is recorded in the event log. 4. The physical IP address is used for communication for synchronizing the clock to an external NTP server. Note that a change to a security setting such as a firewall setting requires permission for communication to be set for not only the virtual IP addresses but also the physical IP addresses of both MMBs (MMB#0 IP address and MMB#1 IP address). 5. If the [Update Now] button is clicked within three minutes after the steps performed as described in "4.5.2 NTP server", synchronization may fail. In this event, wait at least three minutes, and click the button again. 6. Click [OK] to save the settings. Formatiert: Nummerierung und Aufzählungszeichen NTP settings for an Active Directory member If a partition in which Windows is installed is an Active Directory (AD) member, the clock is automatically synchronized with the NTP server of the domain controller. The [Internet Time] tab is not displayed in such cases, as shown in the figure below. A partition in a cluster environment using WSFC must be an Active Directory member. In this case, the clock is automatically synchronized with the NTP server of the domain controller. U41805-J-Z /C122-E087-03EN 84

85 Figure 4-31 [Date and Time] property dialog box (Active Directory environment) 4.6 Saving Setting Information Save PSA setting information and EFI configuration information. For details, see "Section 4.12 Saving Setup Information", in the PRIMEQUEST 500A/500/400 Series Installation Manual (U41632-J-Z816-x-76/C122-E001EN). U41805-J-Z /C122-E087-03EN 85

86 Chapter 5 Maintenance/Operation This chapter explains maintenance such as backup and restore operations, basic settings for operation, and operation of Windows Server System Startup and Shutdown This section explains the system startup and shutdown procedures Starting the system Start a partition from the MMB. For the procedure, see the following manuals: PRIMEQUEST 500A/500/400 Series Reference Manual: Basic Operation/GUI/Command (U41633-J-Z816-x-76/C122-E003EN) PRIMEQUEST 510A Reference Manual: Basic Operation/GUI/Command (C122-E096EN)* Shutting down the system This section describes procedures for shutting down a partition in which Windows Server 2008 is running. Two shutdown methods are available. Shutdown after logon to Windows ( 5.1.3) Log on to Windows with administrator privileges from the console or through a remote desktop connection, and then shut down the system. Shutdown with the shutdown command ( 5.1.4) Perform remote shutdown from a personal computer on which Windows XP or a later version is installed. Note With the standard settings, a partition in which Windows Server 2008 is running cannot be shut down from the MMB. Be sure to refer to the appropriate procedure in this section for shutting down the system. U41805-J-Z /C122-E087-03EN 86

87 5.1.3 Shutdown after logon to Windows Log on to the system through the KVM connected to the cabinet or a remote desktop, and then shut down the system. Prerequisite for shutdown from the KVM The KVM is connected to the cabinet. Prerequisites for shutdown from a remote desktop The management terminal is connected to the target partition via a LAN. The remote desktop connection is enabled in the settings of the target Windows system. In Windows installation according to the procedure explained in Chapter 3, remote desktop connectivity is enabled as a standard setting. Log on to Windows as a user with administrator privileges, and click the shutdown button from the Start menu. Figure 5-1 Shutdown button Shutdown with the shutdown command Windows XP and later provide the shutdown.exe command. This command can be used for remote shutdown from the management terminal. Prerequisites The operating system of the management terminal is any of the following: Windows XP Windows Vista Windows Server 2003 Windows Server 2008 U41805-J-Z /C122-E087-03EN 87

88 The management terminal is connected via a network to the Windows system that will be shut down. Firewall settings of the target Windows system [File and printer sharing] is checked on the [Exceptions] tab for firewall settings. If the target system is in a workgroup environment The user name and password of the management terminal match those of Windows. If the target system is in an Active Directory environment The user has logged on to the management terminal as a user with administrator privileges for the Windows system that will be shut down. Usage shutdown -s -m \\<Server Name> For <Server Name>, specify the name of the Windows computer to be shut down. For details on other options of the shutdown command, see the Help. Simplified help information is displayed by this command executed with the /? option. Figure 5-2 Simplified help information on the shutdown command U41805-J-Z /C122-E087-03EN 88

89 5.2 Backup and Restore This section explains the backup/restore software included in the standard software bundle. SystemcastWizard Lite bundled with the PRIMEQUEST main unit ( 5.2.1) Windows Server Backup, a standard backup function of Windows ( 5.2.2) Backup/Restore using SystemcastWizard Lite SystemcastWizard Lite is included in the standard software bundle for the PRIMEQUEST server, and you can use it to easily back up and restore the system volume via a network. Features Agent or other software components need not be installed on the target system. Work beginning from power-on of the target system until the completion of backup or restore can be performed via a network. SystemcastWizard Lite can be used effectively for work in the system construction stage or system verification stage or in the event of a problem. Data stored as image files in system volume Management Restore Backup SystemcastWizard Lite PRIMEQUEST Figure 5-3 Backup/Restore using SystemcastWizard Lite Remarks U41805-J-Z /C122-E087-03EN 89

90 SystemcastWizard Lite does not support online backup, incremental backup, or differential backup, and it is not suitable for periodic backup after the start of business operation. For backup/restore during business operation, consider Brightstor ARCserve. For details, contact a certified service engineer. For the SystemcastWizard Lite operation methods, see the PRIMEQUEST SystemcastWizard Lite User's Guide (C122-E010EN) Backup/restore using Windows Server Backup Windows Server 2003 and earlier provide Ntbackup as a standard backup function, and Windows Server 2008 supports Windows Server Backup, a completely revised version of the standard backup function. Features of Windows Server Backup Recovery is easier and quicker than Ntbackup. Applications that support Volume Shadow Copy Service (VSS) are linked, ensuring safe backup operations. Its incorporation into the management console (MMC) enables management with a unified UI. Enriched functions executed from the command line are helpful for automating management. Remarks Despite having many advantages over Ntbackup of Windows Server 2003, Windows Server Backup cannot completely replace Ntbackup for reasons such as because it cannot save data to tape media. If data must be saved to tape media or unified backup management is required, consider Brightstor ARCserve. For details, contact a certified service engineer. This section explains the procedure for backing up the system volume to an internal hard disk drive and the U41805-J-Z /C122-E087-03EN 90

91 procedure for restoring backup data. For details on advanced uses such as scheduled backup, see the Help for Windows Server Backup Installation Since the Windows Server Backup function is not installed by default, it must first be installed. Remarks If the Windows Server Backup function has already been installed, this procedure need not be followed. To install the Windows Server Backup function, administrator privileges are required. Log on to the system as a user with administrator privileges, or escalate your privileges first. Procedure 1. Select [Server Manager] from the [Start] menu. 2. Click [Features] in the left pane of [Server Manager]. 3. Click [Add Features] in the right pane of [Server Manager]. 4. The [Select Features] page of the Add Features Wizard is displayed. Click [Windows Server Backup Function] [Windows Server Backup] to check its check box. 5. Click the [Next] button. 6. Click [Install]. 7. Wait until installation is completed. Then, click [Close]. The above step completes the installation procedure. Click the [Start] menu [Administrative Tools] [Windows Server Backup], and then Windows Server Backup starts System backup This section explains the procedure for backing up the system volume to a local disk. Another disk that does not contain the system volume must be prepared. For details on methods of use, see the Help for Windows Server Backup. Remarks To use Windows Server Backup, the privileges of the "Administrator" or "Backup Operators" group are required. Log on to the system as a user with such privileges, or escalate your privileges first. U41805-J-Z /C122-E087-03EN 91

92 Procedure 1. Click the [Start] menu [Administrative Tools] [Windows Server Backup]. 2. Windows Server Backup starts. Click [Backup Once] in the right pane. 3. The [Backup Options] page is displayed. Click the [Next] button. Figure 5-4 Backup Once Wizard ([Backup Options] page) 4. The [Select Backup Configuration] page is displayed. Select [Custom], and click the [Next] button. 5. The [Select Backup Items] page is displayed. Verify the following points, and then click the [Next] button: The selected drive contains the EFI System Partition and has Windows is installed on it (usually, C:). Backup data will not be saved to the selected drive. [I want to be able to perform a system recovery using this backup] is checked. U41805-J-Z /C122-E087-03EN 92

93 Figure 5-5 Backup Once Wizard ([Select Backup Items] page) 6. The [Specify Destination Type] page is displayed. Confirm that [Local drives] is selected, and then click the [Next] button. 7. The [Select Backup Destination] page is displayed. Select the drive to which to save backup data, and click the [Next] button. 8. The [Advanced] page is displayed. Select [VSS full backup], and click the [Next] button. 9. The [Summary] page is displayed. Click the [Backup] button to start backup. Backup processing is executed as a background task. To check whether backup has been completed, check the Windows Server Backup dialog box. The above step completes the backup procedure System restore This section explains the procedure for restoring a system backup image stored on a local disk. For details on methods of use, see the Help for Windows Server Backup. U41805-J-Z /C122-E087-03EN 93

94 Required items KVM (the keyboard, mouse, and display connected to the main unit) Windows Server 2008 Installation DVD-ROM disk PRIMEQUEST Drivers CD for Microsoft Windows Server 2008 (Drivers CD-ROM) Procedure 1. Start the system from the Windows Server 2008 Installation DVD-ROM disk. Insert the Installation DVD-ROM disk into the DVD-ROM drive, and start the system from the DVD-ROM disk. The system takes about 10 minutes to start. 2. The window for selecting a language is displayed. Select an appropriate language. Figure 5-6 Selection of a language 3. The installation window is displayed. Click [Repair your computer] at the lower left. U41805-J-Z /C122-E087-03EN 94

95 Figure 5-7 [Repair your computer] 4. If Windows is already installed on the system, the window for selecting the system to be repaired is displayed. Click [Next] in the displayed window. 5. When the [System Recovery Options] dialog box is displayed, click [Windows Complete PC Restore]. 6. Confirm that [Restore the following backup (recommended)] (the latest backup available) is selected, and then click the [Next] button. 7. The following warning message is displayed: Windows Complete PC Restore will erase all data on the disks you chose to restore. 8. Check [I confirm that I want to erase all existing data and restore the backup.], and the click the [OK] button. The restore begins. 9. The system is automatically restarted when the restore is completed. The above step completes the system restore procedure. U41805-J-Z /C122-E087-03EN 95

96 5.3 Management LAN Reconfiguration Required When the BMM Is Replaced (PRIMEQUEST 580A/540A*/580/540) If BMM hardware is replaced, the management LAN must be reconfigured. Note BMM replacement is a task for a a certified service engineer. If BMM replacement is required, contact a certified service engineer before reconfiguring the management LAN. Since the management LAN of the PRIMEQUEST 520A*/520/510A* uses only one port, these models do not require the settings described in this section. To replace the BMM, follow the procedure below. Delete management LAN teaming setting (PRIMEQUEST 580A/540A*/580/540) Shut down system Replace BMM (Fujitsu service engineer) Reconfigure management LAN teaming (PRIMEQUEST 580A/540A*/580/540) Figure 5-8 BMM replacement flow Deleting the management LAN teaming settings (PRIMEQUEST 580A/540A*/580/540) Before replacing the BMM, record and then delete the management LAN teaming settings. *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 96

97 Note The team name and TCP/IP settings (IP address, subnet mask, and default gateway) are deleted when the teaming settings are deleted. Before deleting the teaming settings, record this information. 1. Select the [Start] menu [Server Manager]. 2. In the [Server Manager] window, select [Diagnostics] [Device Manager]. Figure 5-9 Server Manager (Device Manager) window 3. Expand [Network Adapters]. Select and right-click the device whose device name is the specified team name (e.g., Team#0), and then select [Properties] from the menu. 4. The [Properties] dialog box is displayed. Select the [Settings] tab. U41805-J-Z /C122-E087-03EN 97

98 Figure 5-10 [team#0 Properties] dialog box 5. Click the [Remove Team] button. Click [Yes] in the confirmation message dialog box. Figure 5-11 Confirmation message dialog box Setting management LAN teaming (PRIMEQUEST 580A/540A*/580/540) Restore the management LAN teaming settings. For the procedure, see "4.1.1 Management LAN settings". Feldfunktion geändert Feldfunktion geändert Formatiert: Französisch (Frankreich) *: not supported by Fujitsu Technology Solutions U41805-J-Z /C122-E087-03EN 98

FUJITSU Software PRIMECLUSTER GLS for Windows. GLS Setup Guide for Cluster Systems 4.4

FUJITSU Software PRIMECLUSTER GLS for Windows. GLS Setup Guide for Cluster Systems 4.4 FUJITSU Software PRIMECLUSTER GLS for Windows GLS Setup Guide for Cluster Systems 4.4 B1FN-5996-01ENZ0(00) January 2017 Preface Purpose of this Manual This manual is intended to explain installation procedures

More information

PRIMEQUEST 580A/540A

PRIMEQUEST 580A/540A U41799-J-Z816-1-76/C122-E085-02EN PRIMEQUEST 580A/540A Dynamic Partitioning (DP) Manual (errata 2008/09/19 incorporated) Please note the table of corrections (errata) 2009/3/31 at the end of the manual.

More information

Cluster Configuration Design Guide (Linux/PRIMECLUSTER)

Cluster Configuration Design Guide (Linux/PRIMECLUSTER) C122-A007-04EN PRIMEQUEST 1000 Series Cluster Configuration Design Guide (Linux/PRIMECLUSTER) FUJITSU LIMITED Preface This manual describes the network and shared I/O unit information and configuration

More information

FUJITSU Server PRIMEQUEST 2000 Series Administration Manual

FUJITSU Server PRIMEQUEST 2000 Series Administration Manual FUJITSU Server PRIMEQUEST 2000 Series Administration Manual CA92344-0537-01 Preface Preface This manual describes the functions and features of the PRIMEQUEST 2000 series. The manual is intended for system

More information

C122-E159-02EN PRIMEQUEST 1000 Series Notices for ServerView Suite

C122-E159-02EN PRIMEQUEST 1000 Series Notices for ServerView Suite PRIMEQUEST 1000 Series Notices for ServerView Suite 2012 January FUJITSU LIMITED Contents I. Preface... 3 II. Notices for ServerView Suite V10.11.07... 4 1. Notices for ServerView Operations Manager (SVOM)...

More information

The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix.

The Contents and Structure of this Manual. This document is composed of the following three chapters and an appendix. Preface This document briefly explains the operations that need to be performed by the user in order to connect an ETERNUS2000 model 100 or 200, ETERNUS4000 model 300, 400, 500, or 600, or ETERNUS8000

More information

FUJITSU Server PRIMEQUEST 1000 Series How to Confirm the IO Product Version

FUJITSU Server PRIMEQUEST 1000 Series How to Confirm the IO Product Version C122-E162-02EN FUJITSU Server PRIMEQUEST 1000 Series How to Confirm the IO Product Version This document describes how to confirm the firmware versions of IO products. CHAPTER 1 Firmware Version of the

More information

Reinstalling the Operating System on the Dell PowerVault 745N

Reinstalling the Operating System on the Dell PowerVault 745N Reinstalling the Operating System on the Dell PowerVault 745N This document details the following steps to reinstall the operating system on a PowerVault 745N system: 1. Install the Reinstallation Console

More information

Installing the Operating System or Hypervisor

Installing the Operating System or Hypervisor If you purchased E-Series Server or NCE Option 1 (E-Series Server or NCE without a preinstalled operating system or hypervisor), you must install an operating system or hypervisor. This chapter includes

More information

HP Supporting the HP ProLiant Storage Server Product Family.

HP Supporting the HP ProLiant Storage Server Product Family. HP HP0-698 Supporting the HP ProLiant Storage Server Product Family https://killexams.com/pass4sure/exam-detail/hp0-698 QUESTION: 1 What does Volume Shadow Copy provide?. A. backup to disks B. LUN duplication

More information

A698HKBH9-E-I RFID Data Management Pro for Fixed Readers Installation Guide. June 2017 Version 2.40

A698HKBH9-E-I RFID Data Management Pro for Fixed Readers Installation Guide. June 2017 Version 2.40 A698HKBH9-E-I-0240 RFID Data Management Pro for Fixed Readers Installation Guide June 2017 Version 2.40 -i- Preface This document explains the procedure of the installation and the Confirmation of RFID

More information

Setup Guide. FUJITSU Software. Serverview Infrastructure Manager Plug-in for. Microsoft System Center. Virtual Machine Manager 1.2

Setup Guide. FUJITSU Software. Serverview Infrastructure Manager Plug-in for. Microsoft System Center. Virtual Machine Manager 1.2 FUJITSU Software Serverview Infrastructure Manager Plug-in for Microsoft System Center Virtual Machine Manager 1.2 Setup Guide For Windows Server 2016 CA92344-2184-01 Dec, 2017 Preface Purpose This Setup

More information

PRIMECLUSTER GLS for Windows. User's Guide 4.3

PRIMECLUSTER GLS for Windows. User's Guide 4.3 PRIMECLUSTER GLS for Windows User's Guide 4.3 B1FN-5851-02ENZ0(02) March 2012 Preface Purpose of this Manual This manual is intended to explain how to install, operate, and administer PRIMECLUSTER GLS

More information

NEC Express5800 Series

NEC Express5800 Series NEC Express5800 Series NEC Express5800/120Rf-1,120Rh-2 Operation Manual For Microsoft Windows Server 2003, Standard x64 Edition / Microsoft Windows Server 2003, Enterprise x64 Edition Note: Microsoft and

More information

Configuration Guide -Server Connection-

Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that

More information

FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux-

FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux- FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux- C122-A017-01EN Table of Contents Preface P.3 1. Operation Status Monitoring 1.1 System Monitoring Overview P.6 1.2

More information

EXPRESSCLUSTER X SingleServerSafe 3.3 for Windows. Installation Guide. 01/29/2016 3rd Edition

EXPRESSCLUSTER X SingleServerSafe 3.3 for Windows. Installation Guide. 01/29/2016 3rd Edition EXPRESSCLUSTER X SingleServerSafe 3.3 for Windows Installation Guide 01/29/2016 3rd Edition Revision History Edition Revised Date Description 1st 02/09/2015 New manual 2nd 04/20/2015 Corresponds to the

More information

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information... Installation Checklist HP ProLiant Cluster F500 for Enterprise Virtual Array 4000/6000/8000 using Microsoft Windows Server 2003, Enterprise Edition Stretch Cluster May 2005 Table of Contents ProLiant Cluster

More information

EXPRESSCLUSTER X SingleServerSafe 3.3 for Windows. Installation Guide. 10/02/2017 6th Edition

EXPRESSCLUSTER X SingleServerSafe 3.3 for Windows. Installation Guide. 10/02/2017 6th Edition EXPRESSCLUSTER X SingleServerSafe 3.3 for Windows Installation Guide 10/02/2017 6th Edition Revision History Edition Revised Date Description 1st 02/09/2015 New manual 2nd 04/20/2015 Corresponds to the

More information

PRIMECLUSTER GLS for Windows. User's Guide 4.3

PRIMECLUSTER GLS for Windows. User's Guide 4.3 PRIMECLUSTER GLS for Windows User's Guide 4.3 B1FN-5851-03ENZ0(01) August 2012 Preface Purpose of this Manual This manual is intended to explain how to install, operate, and administer PRIMECLUSTER GLS

More information

ExpressCluster X SingleServerSafe 3.2 for Windows. Installation Guide. 2/19/2014 1st Edition

ExpressCluster X SingleServerSafe 3.2 for Windows. Installation Guide. 2/19/2014 1st Edition ExpressCluster X SingleServerSafe 3.2 for Windows Installation Guide 2/19/2014 1st Edition Revision History Edition Revised Date Description First 2/19/2014 New manual Copyright NEC Corporation 2014. All

More information

FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux-

FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux- FUJITSU Server PRIMEQUEST 2000 Series Linux Operation Guide -Red Hat Enterprise Linux- CA92344-0702-02 Table of Contents Preface P.3 1. Operation Status Monitoring 1.1 System Monitoring Overview P.6 1.2

More information

FUJITSU Server PRIMEQUEST 2000 Series Design Guide

FUJITSU Server PRIMEQUEST 2000 Series Design Guide FUJITSU Server PRIMEQUEST 2000 Series Design Guide C122-A014-01EN Table of Contents Preface P.4 1. PRIMEQUEST Overview 1.1 Product Lineup P.8 1.2 Specifications P.9 1.3 Supported OS P.10 1.4 Component

More information

PS Series Best Practices Deploying Microsoft Windows Clustering with an iscsi SAN

PS Series Best Practices Deploying Microsoft Windows Clustering with an iscsi SAN PS Series Best Practices Deploying Microsoft Windows Clustering with an iscsi SAN Abstract This Technical Report describes how to use PS Series storage arrays with a Microsoft Windows Server 2003 cluster.

More information

FUJITSU Server PRIMEQUEST 1000 Series

FUJITSU Server PRIMEQUEST 1000 Series FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual C122-E155-04EN Preface This manual is a revised version of APPENDIX D Configuring the SAN Boot Environment from the PRIMEQUEST

More information

Farstone TotalDeploy User Guide

Farstone TotalDeploy User Guide Farstone TotalDeploy User Guide 1 Introduction to TotalDeploy...3 1.1 Overview...3 1.1.1 What is TotalDeploy...3 1.1.2 Who needs TotalDeploy?...3 1.1.3 TotalDeploy infrastructure...3 1.2 What you can do

More information

FUJITSU Software. Serverview Infrastructure Manager Plug-in for. Microsoft System Center. Operations Manager 1.2. Setup Guide. For Windows Server 2016

FUJITSU Software. Serverview Infrastructure Manager Plug-in for. Microsoft System Center. Operations Manager 1.2. Setup Guide. For Windows Server 2016 FUJITSU Software Serverview Infrastructure Manager Plug-in for Microsoft System Center Operations Manager 1.2 Setup Guide For Windows Server 2016 CA92344-2182-01 Dec, 2017 1 Preface Purpose This Setup

More information

VMware vsphere Storage Appliance Installation and Configuration

VMware vsphere Storage Appliance Installation and Configuration VMware vsphere Storage Appliance Installation and Configuration vsphere Storage Appliance 1.0 vsphere 5.0 This document supports the version of each product listed and supports all subsequent versions

More information

This page is intentionally left blank.

This page is intentionally left blank. This page is intentionally left blank. Preface This ETERNUS Multipath Driver User's Guide describes the features, functions, and operation of the "ETERNUS Multipath Driver" (hereafter referred to as "Multipath

More information

FUJITSU Software. ServerView Infrastructure Manager Plug-in for. VMware vcenter Server 1.1. Setup Guide. For vcenter Server 6.0

FUJITSU Software. ServerView Infrastructure Manager Plug-in for. VMware vcenter Server 1.1. Setup Guide. For vcenter Server 6.0 FUJITSU Software ServerView Infrastructure Manager Plug-in for VMware vcenter Server 1.1 Setup Guide For vcenter Server 6.0 CA92344-2178-01 Dec, 2017 1 Preface Purpose This Setup Guide describes the installation

More information

FUJITSU Server PRIMEQUEST 1000 Series

FUJITSU Server PRIMEQUEST 1000 Series FUJITSU Server PRIMEQUEST 1000 Series SAN Boot Environment Configuration Manual C122-E155-05EN Preface This manual is a revised version of APPENDIX D Configuring the SAN Boot Environment from the PRIMEQUEST

More information

EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version

EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version Installation and Administration Guide P/N 300-007-130 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000

More information

Configuration Guide -Server Connection-

Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX, ETERNUS AF Configuration Guide -Server Connection- (Fibre Channel) for Windows This page is intentionally left blank. Preface This manual briefly explains the operations that

More information

x10sure 3.2 One to one recover after repair

x10sure 3.2 One to one recover after repair x10sure 3.2 One to one recover after repair 1 1:1 WITH EXTERNAL STORAGE 2 1.1 After power failure etc. 2 1.2 After repair 2 1.3 After replacement of the failed node 3 1.3.1 Boot device via FC 3 1.3.2 Boot

More information

PRIMECLUSTER Global Link Services Configuration and Administration Guide: Redundant Line Control Function V4.1

PRIMECLUSTER Global Link Services Configuration and Administration Guide: Redundant Line Control Function V4.1 PRIMECLUSTER Global Link Services Configuration and Administration Guide: Redundant Line Control Function V4.1 Preface This manual describes PRIMECLUSTER GLS (Redundant Line Control Function) and explains

More information

HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes

HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes Part number: AA RV22F TE Sixth edition: August 2006 Legal and notice information Copyright

More information

Fibre Channel card Users Guide

Fibre Channel card Users Guide C122-E012-19EN PRIMEQUEST Fibre Channel card Users Guide 2G Fibre Channel PCI-X card (MC-08FC11/ MC-08FC71) 4G Fibre Channel PCI-X card (MC-08FC31/ MC-08FC41) 4G Fibre Channel PCI-express card (MC-08FC51/

More information

EXPRESSBUILDER 3.005b-G Update Notes

EXPRESSBUILDER 3.005b-G Update Notes Express5800/320Lb Software Notes EXPRESSBUILDER 3.005b-G Update Notes Express5800/320Lb EXPRESSBUILDER 3.005b-G Update Notes Page 1 of 9 Proprietary Notice and Liability Disclaimer The information disclosed

More information

FUJITSU Software. Infrastructure Manager Plug-in for Microsoft. System Center. Operations Manager 1.2. Setup Guide. For Windows Server 2016 / 2019

FUJITSU Software. Infrastructure Manager Plug-in for Microsoft. System Center. Operations Manager 1.2. Setup Guide. For Windows Server 2016 / 2019 FUJITSU Software Infrastructure Manager Plug-in for Microsoft System Center Operations Manager 1.2 Setup Guide For Windows Server 2016 / 2019 CA92344-2546-02 October, 2018 1 Contents Preface... 3 Purpose...

More information

Installation Guide (Windows)

Installation Guide (Windows) Installation Guide (Windows) NEC Express Server Express5800 Series Express5800/R310e-E4 Express5800/R320e-E4 Express5800/R320e-M4 Express5800/R310f-E4 Express5800/R320f-E4 Express5800/R320f-M4 EXP320R,

More information

FUJITSU Software. ServerView Infrastructure Manager Plug-in for. VMware vcenter Server Appliance 1.1. Setup Guide. For vcenter Server Appliance 6.

FUJITSU Software. ServerView Infrastructure Manager Plug-in for. VMware vcenter Server Appliance 1.1. Setup Guide. For vcenter Server Appliance 6. FUJITSU Software ServerView Infrastructure Manager Plug-in for VMware vcenter Server Appliance 1.1 Setup Guide For vcenter Server Appliance 6.0 CA92344-1949-01 Aug, 2017 1 Preface Purpose This Setup Guide

More information

Quick Setup & Getting Started

Quick Setup & Getting Started Quick Setup & Getting Started HP Compaq Business PC Copyright 2007 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft, Windows, and

More information

Express5800/R120d-1M, R120d-2M

Express5800/R120d-1M, R120d-2M NEC Express Server Express5800 Series Express5800/R120d-1M, R120d-2M EXP291, EXP292 Installation Guide (Windows) Model Number: R120d-1M N8100-1794F R120d-2M N8100-1793F Chapter 1 Installing Windows Chapter

More information

Parallels Containers for Windows 6.0

Parallels Containers for Windows 6.0 Parallels Containers for Windows 6.0 Deploying Microsoft Clusters June 10, 2014 Copyright 1999-2014 Parallels IP Holdings GmbH and its affiliates. All rights reserved. Parallels IP Holdings GmbH Vordergasse

More information

DeploymentManager Ver6.3

DeploymentManager Ver6.3 DeploymentManager Ver6.3 Operation Guide -First Edition- Rev.001 Contents Introduction... 4 Target Audience and Purpose... 4 Document Structure... 4 DeploymentManager Manual Organization... 4 Documentation

More information

Step-by-Step Guide to Installing Cluster Service

Step-by-Step Guide to Installing Cluster Service Page 1 of 23 TechNet Home > Products & Technologies > Windows 2000 Server > Deploy > Configure Specific Features Step-by-Step Guide to Installing Cluster Service Topics on this Page Introduction Checklists

More information

SystemWalker/StorageMGR User's Guide Solaris-

SystemWalker/StorageMGR User's Guide Solaris- SystemWalker/StorageMGR User's Guide 10.0 -Solaris- Preface ++ Purpose This manual explains how to operate Web-GUI with SystemWalker/StorageMGR. SystemWalker is a generic name for products for operation

More information

Windows Server 2016 Installation Guide

Windows Server 2016 Installation Guide Windows Server 2016 Installation Guide NEC Express Server Express5800 Series Express5800/ T110g-S, T110g-E, R110g-1E Chapter 2 Maintenance Chapter 3 Appendix CBZ-002473-080-00 NEC Corporation 2017 Contents

More information

Cisco VDS Service Broker Software Installation Guide for UCS Platforms

Cisco VDS Service Broker Software Installation Guide for UCS Platforms Cisco VDS Service Broker 1.0.1 Software Installation Guide for UCS Platforms Revised: May 2013 This document provides detailed instructions for installing the Cisco Videoscape Distribution Suite Service

More information

DeploymentManager Ver6.5

DeploymentManager Ver6.5 DeploymentManager Ver6.5 Tool Reference Guide - Second Edition - Rev.001 Contents Introduction... 4 Target Audience and Purpose... 4 Document Structure... 4 Documentation Guidelines for DeploymentManager

More information

B1FN ENZ0(02) PRIMEQUEST. System Disk Mirror for Windows User's Guide V1.0

B1FN ENZ0(02) PRIMEQUEST. System Disk Mirror for Windows User's Guide V1.0 B1FN-5771-01ENZ0(02) PRIMEQUEST System Disk Mirror for Windows User's Guide V1.0 Preface Purpose of This Manual This manual describes the functions and usage of PRIMEQUEST System Disk Mirror for Windows

More information

ExpressCluster X 2.0 for Linux

ExpressCluster X 2.0 for Linux ExpressCluster X 2.0 for Linux Installation and Configuration Guide 03/31/2009 3rd Edition Revision History Edition Revised Date Description First 2008/04/25 New manual Second 2008/10/15 This manual has

More information

DeploymentManager Ver6.6

DeploymentManager Ver6.6 DeploymentManager Ver6.6 Operation Guide -First Edition- Rev.001 Contents Introduction... 4 Target Audience and Purpose... 4 Document Structure... 4 Documentation Guidelines for DeploymentManager Manuals...

More information

DeploymentManager Ver6.1

DeploymentManager Ver6.1 DeploymentManager Ver6.1 Operation Guide -Third Edition- Rev.001 Contents Introduction... 3 Target Audience and Purpose... 3 Document Structure... 3 DeploymentManager Manual Organization... 3 Documentation

More information

Microsoft Windows NT Microsoft Windows SystemWalker/StorageMGR. User's Guide V10.0L10

Microsoft Windows NT Microsoft Windows SystemWalker/StorageMGR. User's Guide V10.0L10 Microsoft Windows NT Microsoft Windows 2000 SystemWalker/StorageMGR User's Guide V10.0L10 Preface ++ Purpose This manual explains how to operate Web-GUI with SystemWalker/StorageMGR. SystemWalker is a

More information

ServerView Integration V4.0 in HP Operations Manager

ServerView Integration V4.0 in HP Operations Manager User Guide - English FUJITSU Software ServerView Suite ServerView Integration V4.0 in HP Operations Manager Edition August 2017 Comments Suggestions Corrections The User Documentation Department would

More information

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05 EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N 300-002-038 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2004-2006

More information

Setup for Failover Clustering and Microsoft Cluster Service

Setup for Failover Clustering and Microsoft Cluster Service Setup for Failover Clustering and Microsoft Cluster Service Update 1 ESXi 5.0 vcenter Server 5.0 This document supports the version of each product listed and supports all subsequent versions until the

More information

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E

Sidewinder. Hardware Guide Models S1104, S2008, S3008. Revision E Sidewinder Hardware Guide Models S1104, S2008, S3008 Revision E Table of contents Preface...3 Find product documentation... 3 1 Introducing the appliances... 4 Models and features... 4 Supported software...

More information

Cisco C880 M4 Server Service Guide for Server with E v3 CPU. November, CA

Cisco C880 M4 Server Service Guide for Server with E v3 CPU. November, CA Cisco C880 M4 Server Service Guide for Server with E7-8800 v3 CPU November, 2015 1 THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT TO CHANGE WITHOUT NOTICE. ALL STATEMENTS,

More information

EXPRESS5800/320Lb/320Lb-R EXPRESSBUILDER

EXPRESS5800/320Lb/320Lb-R EXPRESSBUILDER EXPRESS5800/320Lb/320Lb-R EXPRESSBUILDER () User s Guide Proprietary Notice and Liability Disclaimer The information disclosed in this document, including all designs and related materials, is the valuable

More information

Parallels Virtuozzo Containers 4.6 for Windows

Parallels Virtuozzo Containers 4.6 for Windows Parallels Parallels Virtuozzo Containers 4.6 for Windows Deploying Microsoft Clusters Copyright 1999-2010 Parallels Holdings, Ltd. and its affiliates. All rights reserved. Parallels Holdings, Ltd. c/o

More information

3.1. Storage. Direct Attached Storage (DAS)

3.1. Storage. Direct Attached Storage (DAS) 3.1. Storage Data storage and access is a primary function of a network and selection of the right storage strategy is critical. The following table describes the options for server and network storage.

More information

DSI Optimized Backup & Deduplication for VTL Installation & User Guide

DSI Optimized Backup & Deduplication for VTL Installation & User Guide DSI Optimized Backup & Deduplication for VTL Installation & User Guide Restore Virtualized Appliance Version 4 Dynamic Solutions International, LLC 373 Inverness Parkway Suite 110 Englewood, CO 80112 Phone:

More information

Printer Driver. Installation Guide. November 2014 Version Copyright FUJITSU LIMITED

Printer Driver. Installation Guide. November 2014 Version Copyright FUJITSU LIMITED Printer Driver Installation Guide November 2014 Version 1.00 -i- Preface This document explains the procedure of the installation and the Confirmation of ZXP-7 Driver (Hereafter, it is written, "This

More information

Cover. MATWorX Installation Guide NWA ISSUE 2.1

Cover. MATWorX Installation Guide NWA ISSUE 2.1 Cover MATWorX Installation Guide NWA-008862-001 ISSUE 2.1 LIABILITY DISCLAIMER NEC Corporation reserves the right to change the specifications, functions, or features, at any time, without notice. NEC

More information

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection-

FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- FUJITSU Storage ETERNUS DX Configuration Guide -Server Connection- (SAS) for VMware ESX This page is intentionally left blank. Preface This manual briefly explains the operations that need to be performed

More information

NEC ESMPRO AlertManager User's Guide

NEC ESMPRO AlertManager User's Guide NEC ESMPRO AlertManager User's Guide Chapter 1 General Description Chapter 2 Installation Chapter 3 Setting Chapter 4 Appendix AM_E-UG-W-001-01-004 NEC Corporation 2014 Contents Contents... 2 Notations

More information

Connectware Manager Getting Started Guide

Connectware Manager Getting Started Guide Connectware Manager Getting Started Guide 90000699_B 2004, 2005 Digi International Inc. Digi, Digi International, the Digi logo, the Digi Connectware log, the Making Device Networking Easy logo, Digi

More information

User's Guide for Infrastructure Administrators (Resource Management)

User's Guide for Infrastructure Administrators (Resource Management) ServerView Resource Orchestrator Cloud Edition V3.0.0 User's Guide for Infrastructure Administrators (Resource Management) Windows/Linux J2X1-7612-01ENZ0(05) April 2012 Preface Purpose This manual provides

More information

User and System Administration

User and System Administration CHAPTER 2 This chapter provides information about performing user and system administration tasks and generating diagnostic information for obtaining technical assistance. The top-level Admin window displays

More information

Configuration and Administration Guide 4.5 Multipath Function

Configuration and Administration Guide 4.5 Multipath Function FUJITSU Software PRIMECLUSTER Global Link Services Configuration and Administration Guide 4.5 Multipath Function Oracle Solaris J2S2-1678-01ENZ0(00) April 2017 Preface This manual describes the capabilities,

More information

Cisco C880 M4 Server User Interface Operating Instructions for Servers with E v2 and E v3 CPUs

Cisco C880 M4 Server User Interface Operating Instructions for Servers with E v2 and E v3 CPUs Cisco C880 M4 Server User Interface Operating Instructions for Servers with E7-8800 v2 and E7-8800 v3 CPUs November, 2015 THE SPECIFICATIONS AND INFORMATION REGARDING THE PRODUCTS IN THIS MANUAL ARE SUBJECT

More information

Cisco UCS Virtual Interface Card Drivers for Windows Installation Guide

Cisco UCS Virtual Interface Card Drivers for Windows Installation Guide Cisco UCS Virtual Interface Card Drivers for Windows Installation Guide First Published: 2011-09-06 Last Modified: 2015-09-01 Americas Headquarters Cisco Systems, Inc. 170 West Tasman Drive San Jose, CA

More information

ClearCube Virtualization. Deployment Guide. ClearCube Technology, Inc.

ClearCube Virtualization. Deployment Guide. ClearCube Technology, Inc. ClearCube Virtualization Deployment Guide ClearCube Technology, Inc. Copyright 2006, 2007, ClearCube Technology, Inc. All rights reserved. Under copyright laws, this publication may not be reproduced or

More information

NEC ESMPRO Manager Ver.6 Setup Guide

NEC ESMPRO Manager Ver.6 Setup Guide Front Cover NEC ESMPRO Manager Ver.6 Setup Guide Chapter 1 Setup for Managed Component integrated EXPRESSSCOPE Engine 3 Chapter 2 Setup for Managed Component integrated BMC excluding EXPRESSSCOPE Engine

More information

Installation and Configuration Guide

Installation and Configuration Guide CYBERSECURITY, EVOLVED EdgeWave iprism Web Security Installation and Configuration Guide V8.0 15333 Avenue of Science, Suite 100 San Diego, CA 92128 Give us a call 1-855-881-2004 Send us an email: info@edgewave.com

More information

VTRAK E-Class/J-Class Quick Start Guide

VTRAK E-Class/J-Class Quick Start Guide VTRAK E-Class/J-Class Quick Start Guide Version.0 Firmware 3.9 008 Promise Technology, Inc. All Rights Reserved. VTrak Quick Start Guide About This Guide This Quick Start Guide shows you how to install

More information

Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020

Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020 Deploying the 55TB Data Warehouse Fast Track Reference Architecture for Microsoft SQL Server 2014 using PowerEdge R730 and Dell Storage SC4020 Dell Storage Engineering December 2015 A Dell Deployment and

More information

ExpressCluster X 3.0 for Windows

ExpressCluster X 3.0 for Windows ExpressCluster X 3.0 for Windows Installation and Configuration Guide 10/01/2010 First Edition Revision History Edition Revised Date Description First 10/01/2010 New manual Copyright NEC Corporation 2010.

More information

INSTALLATION GUIDE. FUJITSU PCI Fibre Channel 4.0 Update2

INSTALLATION GUIDE. FUJITSU PCI Fibre Channel 4.0 Update2 Manual code: C120-E392-03EN INSTALLATION GUIDE FUJITSU PCI Fibre Channel 4.0 Update2 for Solaris Operating System The Customer acknowledges and agrees that the Product is designed, developed and manufactured

More information

ETERNUS SF Express V15.3/ Storage Cruiser V15.3/ AdvancedCopy Manager V15.3. Migration Guide

ETERNUS SF Express V15.3/ Storage Cruiser V15.3/ AdvancedCopy Manager V15.3. Migration Guide ETERNUS SF Express V15.3/ Storage Cruiser V15.3/ AdvancedCopy Manager V15.3 Migration Guide B1FW-5958-06ENZ0(00) June 2013 Preface Purpose This manual describes how to upgrade to this version from the

More information

Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5

Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Setup for Microsoft Cluster Service Update 1 Release for ESX Server 3.5, ESX Server 3i version 3.5, VirtualCenter 2.5 Setup for Microsoft Cluster Service Setup for Microsoft Cluster Service Revision: 041108

More information

VMware vcenter AppSpeed Installation and Upgrade Guide AppSpeed 1.2

VMware vcenter AppSpeed Installation and Upgrade Guide AppSpeed 1.2 VMware vcenter AppSpeed Installation and Upgrade Guide AppSpeed 1.2 This document supports the version of each product listed and supports all subsequent versions until the document is replaced by a new

More information

Trend Micro Incorporated reserves the right to make changes to this document and to the product described herein without notice. Before installing and using the product, please review the readme files,

More information

Windows Server 2016 Installation Guide

Windows Server 2016 Installation Guide Windows Server 2016 Installation Guide NEC Express Server Express5800 Series Express5800/R110h-1, T110h-S, T110h Chapter 1 Installing Windows Chapter 2 Maintenance Chapter 3 Appendix CBZ-002473-066-00

More information

Areas Covered. Chapter 1 Features (Product Overview/Note) Chapter 2 Installation Flow and Note. Chapter 3 Installing Global Array Manager (GAM)

Areas Covered. Chapter 1 Features (Product Overview/Note) Chapter 2 Installation Flow and Note. Chapter 3 Installing Global Array Manager (GAM) PRIMERGY RX200 S2 Onboard SCSI RAID User s Guide Areas Covered Chapter 1 Features (Product Overview/Note) This chapter explains the overview of the disk array and features of this product. Chapter 2 Installation

More information

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5

Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Update 2 and later for ESX Server 3i version 3.5 Installable and VirtualCenter 2.5 Getting Started with ESX Server 3i Installable Revision: 20090313 Item:

More information

Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0

Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0 Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0 Revision 1.0 February 2000 Revision History Revision Revision History Date 1.0 Initial Release 02/10/00 Intel Corporation

More information

Trend Micro Incorporated reserves the right to make changes to this document and to the product described herein without notice. Before installing and using the product, please review the readme files,

More information

NEC ESMPRO Manager Ver.6 Setup Guide

NEC ESMPRO Manager Ver.6 Setup Guide NEC ESMPRO Manager Ver.6 Setup Guide Chapter1 Setup for Managed Component in which EXPRESSSCOPE Engine 3 is integrated Chapter2 Setup for Managed Component in which a BMC excluding EXPRESSSCOPE Engine

More information

Basic System Administration ESX Server and Virtual Center 2.0.1

Basic System Administration ESX Server and Virtual Center 2.0.1 ESX Server 3.0.1 and Virtual Center 2.0.1 Basic System Administration Revision: 2006105 Item: VI-ENG-Q306-293 You can find the most up-to-date technical documentation on our Web site at http://www.vmware.com/support/

More information

Fujitsu ScandAll PRO V2.1.5 README

Fujitsu ScandAll PRO V2.1.5 README -------------------------------------------------------- Fujitsu ScandAll PRO V2.1.5 README -------------------------------------------------------- Copyright PFU Limited 2007-2017 This file contains information

More information

Installing the Server Operating System or Hypervisor

Installing the Server Operating System or Hypervisor Installing the Server Operating System or Hypervisor This chapter includes the following sections: Operating System or Hypervisor Installation Methods, page 1 KVM Console, page 1 PXE Installation Servers,

More information

Virtual Appliance User s Guide

Virtual Appliance User s Guide Cast Iron Integration Appliance Virtual Appliance User s Guide Version 4.5 July 2009 Cast Iron Virtual Appliance User s Guide Version 4.5 July 2009 Copyright 2009 Cast Iron Systems. All rights reserved.

More information

SOFT-AM-0081_R3. AX3800S/AX3600S Software Upgrade Guide

SOFT-AM-0081_R3. AX3800S/AX3600S Software Upgrade Guide AX3800S/AX3600S Software Upgrade Guide Edition 4: November, 2011 1 Preface This document describes how to upgrade the software from L3(L3S) Lite Edition to L3(L3S) Advanced Edition. Read this document

More information

Installation and Configuration Guide

Installation and Configuration Guide Installation and Configuration Guide h-series 800-782-3762 www.edgewave.com 2001 2011 EdgeWave Inc. (formerly St. Bernard Software). All rights reserved. The EdgeWave logo, iprism and iguard are trademarks

More information

RFID Label Design and Encoding Management Pro (Utility Only) Installation Guide. October 2015 Version 1.21 A698HKV99-E-I-0121

RFID Label Design and Encoding Management Pro (Utility Only) Installation Guide. October 2015 Version 1.21 A698HKV99-E-I-0121 A698HKV99-E-I-0121 RFID Label Design and Encoding Management Pro (Utility Only) Installation Guide October 2015 Version 1.21 -i- Preface This document explains the procedure of the installation and the

More information

SNMP Manager User s Manual

SNMP Manager User s Manual SNMP Manager User s Manual Table of Contents 1. Introduction...1 2. SNMP Manager Install, Quick Start and Uninstall...2 2.1. Software Installation...2 2.2. Software Quick Start...2 2.3. Software Uninstall...3

More information

Areas Covered. PRIMERGY BX620 S2 Server Blade User s Guide

Areas Covered. PRIMERGY BX620 S2 Server Blade User s Guide PRIMERGY BX620 S2 Server Blade User s Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Make sure to read this section.

More information