Optical Guidance. Sanford L. Meeks. July 22, 2010

Size: px
Start display at page:

Download "Optical Guidance. Sanford L. Meeks. July 22, 2010"

Transcription

1 Optical Guidance Sanford L. Meeks July 22, 2010

2 Optical Tracking Optical tracking is a means of determining in real-time the position of a patient relative to the treatment unit. Markerbased systems track the positions of either active or passive infrared markers attached to the patient as a surrogate for actual patient position. Markerless systems track the reflection of light from the surface of the patient. The position of the point of reflection is determined using a camera system. Active markers Passive markers Camera

3 Calibration Camera has been correlated with linac isocenter to correlate virtual space with real space.

4 Clinical Applications of Optical Tracking 1. Markers are indexed to patient

5 Clinical Applications of Optical Tracking 2. Markers are identified in CT scan relative to treatment isocenter.

6 Clinical Applications of Optical Tracking 3. Markers are tracked using camera system. CCD Camera Control Computer Fiducial Array Optical guidance to track patient position using passive markers and a bite-plate system.

7 Clinical Applications of Optical Tracking 3. Markers are tracked using camera system.

8 4. Misalignments are corrected.

9 Optical Tracking Extracranial Targets Tracking surface alone may be inadequate Target motion relative to surface anatomy Imaging coupled with optical tracking Ultrasound X-Ray

10 Varian SonArray High-resolution infrared camera Detects passive and active fiducials Computer with Spatial Digitizer linked to Camera Image Processing and Localizing Software Optically tracked ultrasound system

11 Correlation of US with Planning CT

12 BrainLab ExacTrac asi detectors infrared camera Floor mounted stereoscopic kv X-ray tubes X-Ray Registration process: Either bony anatomy (automated) or implanted fiducial markers Patient tracked optically using reflective body markers

13 Observed positions Marker Alignment Expected positions Manual alignment Table Offsets Expected positions Observed positions Manual alignment Patient aligned and tracked using optical guidance

14 Gating with Marker-Based System (BrainLab Exactrac) Because optical tracking gives real-time feedback, it is also useful for generating respiratory gating signal. Gated x-ray verification is performed using implanted fiducials. Can verify at any time, including during treatment

15 Once the breathing signal is obtained the user selects the level of the breathing pattern for which x-rays are to be obtained X-Ray Level

16 Markerless Tracking Use of projection of patterned or structured light onto the scene. Use image feature correspondence in stereo images to track surface. Images from: Siebert et al, Human body 3D imaging by speckle texture projection photogrammetry, Sensor Review 20:3, p 218, Waldron ACMP 2009

17 Markerless Tracking RT Vision sensor system arranged in pods, each is capable of stereo vision. A pod contains 1 stereo pair of cameras and a speckle pattern projector. A texture camera, white flash, and speckle flash projector are also present. Speckle flash Stereo camera pair Speckle projector Texture camera Speckle Pattern Waldron ACMP 2009

18 Commercial Systems Company Varian BrainLab Accuray CMS Nomos Resonant Medical Medical Intelligence VisionRT External tracking, +ultrasound, gating External tracking + x-ray, gating External tracking + x-ray Ultrasound Ultrasound Ultrasound External tracking Surface tracking

19 TG147: QA for non-radiographic localization and positioning systems Disclaimer: This task group is still under review and has not been published (a work in progress)

20 Installation Machine isocenter and in-room laser accuracy (per customer ATP / TG40) Linac interference with localization system Localization system interference Linac (and collision space) Establish Localization Volume (Volume of View) Establish Tracking volume (VOV for Tracking) System Performance

21 Installation Machine isocenter and in-room laser accuracy (per customer ATP / TG40) Recommend the use of a Winston/Lutz film process for establishing machine isocenter / laser QA documentation prior to installation of add-on equipment

22 System Performance Calibration Procedures Overall Localization Accuracy (End to End Test) System Drift Reproducibility Tracking Accuracy Response Time (latency)

23 Target Localization Accuracy and Overall Positional Accuracy (End to End Test)

24 Localization on Treatment Planning System

25 Setup of Patient under Optical Guidance

26 Resulting Film: Measure of Total Accuracy of System Results: Z: 0.49 mm to T X: 0.35 mm to A Y: 0.50 mm High Overall error = 0.789mm

27

28

Thank-You Members of TG147 TG 147: QA for nonradiographic

Thank-You Members of TG147 TG 147: QA for nonradiographic Thank-You Members of TG147 TG 147: QA for nonradiographic localization and positioning systems Twyla Willoughby, M.S. Medical Physicist Clinical AAPM Meeting March 2013 Department of Radiation Oncology

More information

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT

7/31/2011. Learning Objective. Video Positioning. 3D Surface Imaging by VisionRT CLINICAL COMMISSIONING AND ACCEPTANCE TESTING OF A 3D SURFACE MATCHING SYSTEM Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago Learning Objective Describe acceptance

More information

Initial Clinical Experience with 3D Surface Image Guidance

Initial Clinical Experience with 3D Surface Image Guidance Initial Clinical Experience with 3D Surface Image Guidance Amanda Havnen-Smith, Ph.D. Minneapolis Radiation Oncology Ridges Radiation Therapy Center Burnsville, MN April 20 th, 2012 Non-funded research

More information

8/3/2016. Image Guidance Technologies. Introduction. Outline

8/3/2016. Image Guidance Technologies. Introduction. Outline 8/3/26 Session: Image Guidance Technologies and Management Strategies Image Guidance Technologies Jenghwa Chang, Ph.D.,2 Department of Radiation Medicine, Northwell Health 2 Hofstra Northwell School of

More information

Choosing and Commissioning a Video Based Motion Management System

Choosing and Commissioning a Video Based Motion Management System Choosing and Commissioning a Video Based Motion Management System David Shepard Swedish Cancer Institute 2 1 Acknowledgments Daliang Cao, PhD, SCI Mohammed Jermoumi, PhD, SCI Roger Xie, PhD, SCI Malin

More information

Real Time Tumor Motion Tracking with CyberKnife

Real Time Tumor Motion Tracking with CyberKnife Real Time Tumor Motion Tracking with CyberKnife Martina Descovich, Ph.D University of California San Francisco July 16, 2015 Learning objectives Review the principles of real-time tumor motion tracking

More information

1. Learn to incorporate QA for surface imaging

1. Learn to incorporate QA for surface imaging Hania Al-Hallaq, Ph.D. Assistant Professor Radiation Oncology The University of Chicago ***No disclosures*** 1. Learn to incorporate QA for surface imaging into current QA procedures for IGRT. 2. Understand

More information

Introduction. Quality Assurance for Image- Guided Radiation Therapy. Justification for IGRT. Image-Guided Radiation Therapy

Introduction. Quality Assurance for Image- Guided Radiation Therapy. Justification for IGRT. Image-Guided Radiation Therapy Introduction Quality Assurance for Image- Guided Radiation Therapy Jean-Pierre Bissonnette, Ph.D., MCCPM Princess Margaret Hospital, Toronto, Canada IGRT What is it? Rationale Equipment Quality Assurance

More information

Feasibility study of performing IGRT system daily QA using a commercial QA device

Feasibility study of performing IGRT system daily QA using a commercial QA device JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 12, NUMBER 3, summer 2011 Feasibility study of performing IGRT system daily QA using a commercial QA device Jean L.Peng, 1 Darren Kahler, 2 Jonathan

More information

Performance and characteristics of an IR localizing system for radiation therapy

Performance and characteristics of an IR localizing system for radiation therapy JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 7, NUMBER 2, SPRING 2006 Performance and characteristics of an IR localizing system for radiation therapy Yulia Lyatskaya, 1 Hsiao-Ming Lu, 2 and Lee

More information

Commissioning and quality assurance of Calypso four dimensional target localization system in linear accelerator facility

Commissioning and quality assurance of Calypso four dimensional target localization system in linear accelerator facility Technical Note Commissioning and quality assurance of Calypso four dimensional target localization system in linear accelerator facility K. R. Muralidhar, Krishna Komanduri, Birendra Kumar Rout, K. K.

More information

Commissioning and quality assurance of Calypso four dimensional target localization system in linear accelerator facility

Commissioning and quality assurance of Calypso four dimensional target localization system in linear accelerator facility 0 0 0 0 JMP R Commissioning and quality assurance of Calypso four dimensional target localization system in linear accelerator facility K. R. Muralidhar, Krishna Komanduri, Birendra Kumar Rout, K. K. D.

More information

Image Guidance and Beam Level Imaging in Digital Linacs

Image Guidance and Beam Level Imaging in Digital Linacs Image Guidance and Beam Level Imaging in Digital Linacs Ruijiang Li, Ph.D. Department of Radiation Oncology Stanford University School of Medicine 2014 AAPM Therapy Educational Course Disclosure Research

More information

Simple quality assurance method of dynamic tumor tracking with the gimbaled linac system using a light field

Simple quality assurance method of dynamic tumor tracking with the gimbaled linac system using a light field JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 17, NUMBER 5, 2016 Simple quality assurance method of dynamic tumor tracking with the gimbaled linac system using a light field Hideharu Miura, 1a Shuichi

More information

Multi-View Stereo for Community Photo Collections Michael Goesele, et al, ICCV Venus de Milo

Multi-View Stereo for Community Photo Collections Michael Goesele, et al, ICCV Venus de Milo Vision Sensing Multi-View Stereo for Community Photo Collections Michael Goesele, et al, ICCV 2007 Venus de Milo The Digital Michelangelo Project, Stanford How to sense 3D very accurately? How to sense

More information

Data Fusion Virtual Surgery Medical Virtual Reality Team. Endo-Robot. Database Functional. Database

Data Fusion Virtual Surgery Medical Virtual Reality Team. Endo-Robot. Database Functional. Database 2017 29 6 16 GITI 3D From 3D to 4D imaging Data Fusion Virtual Surgery Medical Virtual Reality Team Morphological Database Functional Database Endo-Robot High Dimensional Database Team Tele-surgery Robotic

More information

Laser Systems for Patient Alignment

Laser Systems for Patient Alignment Laser Systems for Patient Alignment GALAXY Patient TOPOGRAPHY Laser System Page: 2 Date: 28 March 2009 The GALAXY System NEW METHOD FOR HIGHER ALIGNMENT ACCURACY. Patient Positioning System for Linac Simulator

More information

3D Scanning. Qixing Huang Feb. 9 th Slide Credit: Yasutaka Furukawa

3D Scanning. Qixing Huang Feb. 9 th Slide Credit: Yasutaka Furukawa 3D Scanning Qixing Huang Feb. 9 th 2017 Slide Credit: Yasutaka Furukawa Geometry Reconstruction Pipeline This Lecture Depth Sensing ICP for Pair-wise Alignment Next Lecture Global Alignment Pairwise Multiple

More information

Combination of Markerless Surrogates for Motion Estimation in Radiation Therapy

Combination of Markerless Surrogates for Motion Estimation in Radiation Therapy Combination of Markerless Surrogates for Motion Estimation in Radiation Therapy CARS 2016 T. Geimer, M. Unberath, O. Taubmann, C. Bert, A. Maier June 24, 2016 Pattern Recognition Lab (CS 5) FAU Erlangen-Nu

More information

Retrospective Spiral Respiratory Correlated Imaging with Varian RPM

Retrospective Spiral Respiratory Correlated Imaging with Varian RPM Retrospective Spiral Respiratory Correlated Imaging with Varian RPM This is a Quick Step Guide for Retrospective Spiral Respiratory Correlated Imaging (4D CT) using the Varian RPM device v1.7 with the

More information

Tumor motion during liver SBRT

Tumor motion during liver SBRT Tumor motion during liver SBRT - projects at Aarhus University Hospital - Per Poulsen, Esben Worm, Walther Fledelius, Morten Høyer Aarhus University Hospital, Denmark SBRT: Stereotactic Body Radiation

More information

Automated Quality Assurance for Image-Guided Radiation Therapy

Automated Quality Assurance for Image-Guided Radiation Therapy JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 10, NUMBER 1, WINTER 2009 Automated Quality Assurance for Image-Guided Radiation Therapy Eduard Schreibmann, a Eric Elder, Tim Fox Department of Radiation

More information

Facility Questionnaire PART I (General Information for 3DCRT and IMRT)

Facility Questionnaire PART I (General Information for 3DCRT and IMRT) Facility Questionnaire PART I (General Information for 3DCRT and IMRT) The following items are required before you can enter cases on any RTOG protocol that requires data submission to the Image-Guided

More information

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC

New Technology in Radiation Oncology. James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC New Technology in Radiation Oncology James E. Gaiser, Ph.D. DABR Physics and Computer Planning Charlotte, NC Technology s s everywhere From the imaging chain To the planning system To the linac To QA..it..it

More information

URGENT IMPORTANT FIELD SAFETY NOTIFICATION

URGENT IMPORTANT FIELD SAFETY NOTIFICATION Subject: Incorrect Movement of the Treatment Table Product: MOSAIQ Scope: Sites affected will be those: 1. Running MOSAIQ and, 2. Treating on linear accelerators with the RATM license Notification Released:

More information

Active Stereo Vision. COMP 4900D Winter 2012 Gerhard Roth

Active Stereo Vision. COMP 4900D Winter 2012 Gerhard Roth Active Stereo Vision COMP 4900D Winter 2012 Gerhard Roth Why active sensors? Project our own texture using light (usually laser) This simplifies correspondence problem (much easier) Pluses Can handle different

More information

Clinical assessment and characterization of a dual-tube kilovoltage X-ray localization system in the radiotherapy treatment room

Clinical assessment and characterization of a dual-tube kilovoltage X-ray localization system in the radiotherapy treatment room JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, VOLUME 9, NUMBER 1, WINTER 2008 Clinical assessment and characterization of a dual-tube kilovoltage X-ray localization system in the radiotherapy treatment

More information

Computer and Machine Vision

Computer and Machine Vision Computer and Machine Vision Lecture Week 12 Part-2 Additional 3D Scene Considerations March 29, 2014 Sam Siewert Outline of Week 12 Computer Vision APIs and Languages Alternatives to C++ and OpenCV API

More information

Accuracy of cranial coplanar beam therapy with BrainLAB ExacTrac image guidance

Accuracy of cranial coplanar beam therapy with BrainLAB ExacTrac image guidance Louisiana State University LSU Digital Commons LSU Master's Theses Graduate School 2007 Accuracy of cranial coplanar beam therapy with BrainLAB ExacTrac image guidance Justin Vinci Louisiana State University

More information

Outline. ETN-FPI Training School on Plenoptic Sensing

Outline. ETN-FPI Training School on Plenoptic Sensing Outline Introduction Part I: Basics of Mathematical Optimization Linear Least Squares Nonlinear Optimization Part II: Basics of Computer Vision Camera Model Multi-Camera Model Multi-Camera Calibration

More information

Version 5.6. Quick Start Guide

Version 5.6. Quick Start Guide WWW..COM Version 5.6 Quick Start Guide STANDARD IMAGING, INC. 3120 Deming Way Middleton, WI 53562-1461 Jul / 2018 2018 Standard Imaging, Inc. TEL 800.261.4446 TEL 608.831.0025 FAX 608.831.2202 DOC # 80714-05

More information

Patient Set-ups and Tumor Localizations

Patient Set-ups and Tumor Localizations Patient Set-ups and Tumor Localizations Amy S. Harrison Patient Positioning Prior to starting any localization or simulation procedure patients need to be positioned and immobilized Patients disease location

More information

The team. Disclosures. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge.

The team. Disclosures. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge. Ultrasound Guidance During Radiation Delivery: Confronting the Treatment Interference Challenge Dimitre Hristov Radiation Oncology Stanford University The team Renhui Gong 1 Magdalena Bazalova-Carter 1

More information

Estimating 3D Respiratory Motion from Orbiting Views

Estimating 3D Respiratory Motion from Orbiting Views Estimating 3D Respiratory Motion from Orbiting Views Rongping Zeng, Jeffrey A. Fessler, James M. Balter The University of Michigan Oct. 2005 Funding provided by NIH Grant P01 CA59827 Motivation Free-breathing

More information

A Comparison between Active and Passive 3D Vision Sensors: BumblebeeXB3 and Microsoft Kinect

A Comparison between Active and Passive 3D Vision Sensors: BumblebeeXB3 and Microsoft Kinect A Comparison between Active and Passive 3D Vision Sensors: BumblebeeXB3 and Microsoft Kinect Diana Beltran and Luis Basañez Technical University of Catalonia, Barcelona, Spain {diana.beltran,luis.basanez}@upc.edu

More information

Mech. Engineering, Comp. Science, and Rad. Oncology Departments. Schools of Engineering and Medicine, Bio-X Program, Stanford University

Mech. Engineering, Comp. Science, and Rad. Oncology Departments. Schools of Engineering and Medicine, Bio-X Program, Stanford University Mech. Engineering, Comp. Science, and Rad. Oncology Departments Schools of Engineering and Medicine, Bio-X Program, Stanford University 1 Conflict of Interest Nothing to disclose 2 Imaging During Beam

More information

8/3/2016. MR-guided RT: Commissioning and Quality Control. Topics for MR-guided RT system commissioning & QC

8/3/2016. MR-guided RT: Commissioning and Quality Control. Topics for MR-guided RT system commissioning & QC MR-guided RT: Commissioning and Quality Control T. Stanescu, PhD, MCCPM Medical Physicist, Princess Margaret Cancer Centre, UHN Assistant Professor, Radiation Oncology, University of Toronto Affiliated

More information

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS

Tomotherapy Physics. Machine Twinning and Quality Assurance. Emilie Soisson, MS Tomotherapy Physics Machine Twinning and Quality Assurance Emilie Soisson, MS Tomotherapy at UW- Madison Treating for nearly 5 years Up to ~45 patients a day on 2 tomo units Units twinned to facilitate

More information

Quick Reference Datasheet For All RIT113 Packages

Quick Reference Datasheet For All RIT113 Packages Quick Reference Datasheet For All RIT113 Packages For Rotational Therapies, IMRT & TG142 Highlights and selected product information only. A complete TG142 brochure is available. For more information on

More information

Real-time monitoring of linac performance using RT plans and logfiles

Real-time monitoring of linac performance using RT plans and logfiles Real-time monitoring of linac performance using RT plans and logfiles NCCAAPM Wisconsin Dells 7 April 2017 Mark Wiesmeyer, PhD, DABR Technical Product Manager Technical talk with insights and results based

More information

CHAPTER 2: THREE DIMENSIONAL TOPOGRAPHICAL MAPPING SYSTEM. Target Object

CHAPTER 2: THREE DIMENSIONAL TOPOGRAPHICAL MAPPING SYSTEM. Target Object CHAPTER 2: THREE DIMENSIONAL TOPOGRAPHICAL MAPPING SYSTEM 2.1 Theory and Construction Target Object Laser Projector CCD Camera Host Computer / Image Processor Figure 2.1 Block Diagram of 3D Areal Mapper

More information

FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION

FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION Philips J. Res. 51 (1998) 197-201 FOREWORD TO THE SPECIAL ISSUE ON MOTION DETECTION AND COMPENSATION This special issue of Philips Journalof Research includes a number of papers presented at a Philips

More information

Block Diagram. Physical World. Image Acquisition. Enhancement and Restoration. Segmentation. Feature Selection/Extraction.

Block Diagram. Physical World. Image Acquisition. Enhancement and Restoration. Segmentation. Feature Selection/Extraction. Block Diagram Physical World Image Acquisition Imaging Image Sampling, Quantization, Compression Image Processing Enhancement and Restoration Segmentation Image Analysis Feature Selection/Extraction Image

More information

State-of-the-Art IGRT

State-of-the-Art IGRT in partnership with State-of-the-Art IGRT Exploring the Potential of High-Precision Dose Delivery and Real-Time Knowledge of the Target Volume Location Antje-Christin Knopf IOP Medical Physics Group Scientific

More information

Homework Assignment /655 (CIRCLE ONE) Fall Instructions and Score Sheet (hand in with answers)

Homework Assignment /655 (CIRCLE ONE) Fall Instructions and Score Sheet (hand in with answers) Homework Assignment 3 601.455/655 (CIRCLE ONE) Fall 2017 Instructions and Score Sheet (hand in with answers) Name Email Other contact information (optional) Signature (required) I have followed the rules

More information

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT

Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT Artefakt-resistente Bewegungsschätzung für die bewegungskompensierte CT Marcus Brehm 1,2, Thorsten Heußer 1, Pascal Paysan 3, Markus Oehlhafen 3, and Marc Kachelrieß 1,2 1 German Cancer Research Center

More information

Tracked surgical drill calibration

Tracked surgical drill calibration Tracked surgical drill calibration An acetabular fracture is a break in the socket portion of the "ball-and-socket" hip joint. The majority of acetabular fractures are caused by some type of highenergy

More information

Real-time self-calibration of a tracked augmented reality display

Real-time self-calibration of a tracked augmented reality display Real-time self-calibration of a tracked augmented reality display Zachary Baum, Andras Lasso, Tamas Ungi, Gabor Fichtinger Laboratory for Percutaneous Surgery, Queen s University, Kingston, Canada ABSTRACT

More information

DEVELOPING AND IMPLEMENTING A HIGH PRECISION SETUP SYSTEM

DEVELOPING AND IMPLEMENTING A HIGH PRECISION SETUP SYSTEM DEVELOPING AND IMPLEMENTING A HIGH PRECISION SETUP SYSTEM By LEE-CHENG PENG A DISSERTATION PRESENTED TO THE GRADUATE SCHOOL OF THE UNIVERSITY OF FLORIDA IN PARTIAL FULFILLMENT OF THE REQUIREMENTS FOR THE

More information

Real-Time Data Acquisition for Cardiovascular Research

Real-Time Data Acquisition for Cardiovascular Research Real-Time Data Acquisition for Cardiovascular Research Andras Lasso, PhD Laboratory for Percutaneous Surgery School of Computing, Queen s University, Kingston Questions / challenges What hardware/software

More information

Geometrical Measurements of the TEC Elements

Geometrical Measurements of the TEC Elements A.Ostaptchouk, D.Pandoulas, S.Schael, R.Siedling I. Physikalisches Institut, RWTH-Aachen Goals internal survey external survey LINK calibration Means 3D CMM Cosmics Geodesy Procedure Conclusions Talk presented

More information

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory

INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1 Modifications for P551 Fall 2013 Medical Physics Laboratory Introduction Following the introductory lab 0, this lab exercise the student through

More information

INNOVATIVE LASER POSITIONING SOLUTIONS IN RADIATION ONCOLOGY.

INNOVATIVE LASER POSITIONING SOLUTIONS IN RADIATION ONCOLOGY. INNOVATIVE LASER POSITIONING SOLUTIONS IN RADIATION ONCOLOGY www.cyrpa.com TREATMENT ROOM HITM : FIXED MOTORISED LASERS Adapted to each radiation treatment room, the HITM positioning system differentiates

More information

P1: OTA/XYZ P2: ABC c01 JWBK288-Cyganek December 5, :11 Printer Name: Yet to Come. Part I COPYRIGHTED MATERIAL

P1: OTA/XYZ P2: ABC c01 JWBK288-Cyganek December 5, :11 Printer Name: Yet to Come. Part I COPYRIGHTED MATERIAL Part I COPYRIGHTED MATERIAL 1 Introduction The purpose of this text on stereo-based imaging is twofold: it is to give students of computer vision a thorough grounding in the image analysis and projective

More information

doi: /j.ijrobp

doi: /j.ijrobp doi:10.1016/j.ijrobp.2010.02.052 Int. J. Radiation Oncology Biol. Phys., Vol. 79, No. 1, pp. 269 278, 2011 Copyright Ó 2011 Elsevier Inc. Printed in the USA. All rights reserved 0360-3016/$ see front matter

More information

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588

ICARO Vienna April Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 ICARO Vienna April 27-29 2009 Implementing 3D conformal radiotherapy and IMRT in clinical practice: Recommendations of IAEA- TECDOC-1588 M. Saiful Huq, Ph.D., Professor and Director, Dept. of Radiation

More information

MR-guided radiotherapy: Vision, status and research at the UMC Utrecht. Dipl. Ing. Dr. Markus Glitzner

MR-guided radiotherapy: Vision, status and research at the UMC Utrecht. Dipl. Ing. Dr. Markus Glitzner MR-guided radiotherapy: Vision, status and research at the UMC Utrecht Dipl. Ing. Dr. Markus Glitzner About myself Training Medizintechnik TU Graz PhD UMC Utrecht Clinical work Software implementation

More information

Raising the Bar in IMRT QA

Raising the Bar in IMRT QA MapCHECK 2TM Raising the Bar in IMRT QA The leader in quick and precise measurement of modulated radiotherapy beams Benefits Proven solution for film-less rotational delivery and IMRT QA - More than 1500

More information

Freestyle 3D. Features and applications. Dr. Daniel Döring Team Lead Product Development Freestyle 1

Freestyle 3D. Features and applications. Dr. Daniel Döring Team Lead Product Development Freestyle 1 Freestyle 3D Features and applications Dr. Daniel Döring Team Lead Product Development Freestyle 1 3D scanning Building works: How to record data? How to check what has been built? How to fit in new parts?

More information

3D Photography: Stereo

3D Photography: Stereo 3D Photography: Stereo Marc Pollefeys, Torsten Sattler Spring 2016 http://www.cvg.ethz.ch/teaching/3dvision/ 3D Modeling with Depth Sensors Today s class Obtaining depth maps / range images unstructured

More information

Dynamic Image Prediction Using Principal Component and Multi-Channel Singular Spectral Analysis: A Feasibility Study

Dynamic Image Prediction Using Principal Component and Multi-Channel Singular Spectral Analysis: A Feasibility Study Open Journal of Medical Imaging, 205, 5, 33-42 Published Online September 205 in SciRes. http://www.scirp.org/journal/ojmi http://dx.doi.org/0.4236/ojmi.205.5307 Dynamic Image Prediction Using Principal

More information

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques

8/4/2016. Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery. Disclosure. Introduction: Treatment delivery techniques Emerging Linac based SRS/SBRT Technologies with Modulated Arc Delivery Lei Ren, Ph.D. Duke University Medical Center 2016 AAPM 58 th annual meeting, Educational Course, Therapy Track Disclosure I have

More information

3D Photography: Active Ranging, Structured Light, ICP

3D Photography: Active Ranging, Structured Light, ICP 3D Photography: Active Ranging, Structured Light, ICP Kalin Kolev, Marc Pollefeys Spring 2013 http://cvg.ethz.ch/teaching/2013spring/3dphoto/ Schedule (tentative) Feb 18 Feb 25 Mar 4 Mar 11 Mar 18 Mar

More information

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE

IMSURE QA SOFTWARE FAST, PRECISE QA SOFTWARE QA SOFTWARE FAST, PRECISE Software for accurate and independent verification of monitor units, dose, and overall validity of standard, IMRT, VMAT, SRS and brachytherapy plans no film, no phantoms, no linac

More information

Measurement of 3D Foot Shape Deformation in Motion

Measurement of 3D Foot Shape Deformation in Motion Measurement of 3D Foot Shape Deformation in Motion Makoto Kimura Masaaki Mochimaru Takeo Kanade Digital Human Research Center National Institute of Advanced Industrial Science and Technology, Japan The

More information

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon

Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon Position accuracy analysis of the stereotactic reference defined by the CBCT on Leksell Gamma Knife Icon WHITE PAPER Introduction An image guidance system based on Cone Beam CT (CBCT) is included in Leksell

More information

S. Guru Prasad, Ph.D., DABR

S. Guru Prasad, Ph.D., DABR PURPOSE S. Guru Prasad, Ph.D., DABR Director of Medical Physics IAEA Consultant NorthShore University Health System and University of Chicago, Pritzker School of Medicine Current TPS utilize more information

More information

A Study of Motion Tracking Accuracy of Robotic Radiosurgery Using a Novel CCD Camera Based End-to-end Test System

A Study of Motion Tracking Accuracy of Robotic Radiosurgery Using a Novel CCD Camera Based End-to-end Test System A Study of Motion Tracking Accuracy of Robotic Radiosurgery Using a Novel CCD Camera Based End-to-end Test System Lei Wang 1, Brett Nelson 2,Youming Yang 1 1. Department of Radiation Oncology, Stanford

More information

Digital Volume Correlation for Materials Characterization

Digital Volume Correlation for Materials Characterization 19 th World Conference on Non-Destructive Testing 2016 Digital Volume Correlation for Materials Characterization Enrico QUINTANA, Phillip REU, Edward JIMENEZ, Kyle THOMPSON, Sharlotte KRAMER Sandia National

More information

Brilliance CT Big Bore.

Brilliance CT Big Bore. 1 2 2 There are two methods of RCCT acquisition in widespread clinical use: cine axial and helical. In RCCT with cine axial acquisition, repeat CT images are taken each couch position while recording respiration.

More information

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF

Acknowledgments. Ping Xia, Ph.D., UCSF. Pam Akazawa, CMD, UCSF. Cynthia Chuang, Ph.D., UCSF Page 1 Quality Assurance of IMRT Delivery Systems - Siemens Lynn J. Verhey, Ph.D. Professor and Vice-Chair UCSF Dept. of Radiation Oncology AAPM 22 Annual Meeting, Montreal Acknowledgments Ping Xia, Ph.D.,

More information

Robot Control for Medical Applications and Hair Transplantation

Robot Control for Medical Applications and Hair Transplantation Dr. John Tenney Director of Research Restoration Robotics, Inc. Robot Control for Medical Applications and Hair Transplantation Presented to the IEEE Control Systems Society, Santa Clara Valley 18 November

More information

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology

VALIDATION OF DIR. Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology VALIDATION OF DIR Raj Varadhan, PhD, DABMP Minneapolis Radiation Oncology Overview Basics: Registration Framework, Theory Discuss Validation techniques Using Synthetic CT data & Phantoms What metrics to

More information

Experimental investigation of a general real-time 3D target localization method using sequential kv imaging combined with respiratory monitoring

Experimental investigation of a general real-time 3D target localization method using sequential kv imaging combined with respiratory monitoring IOP PUBLISHING Phys. Med. Biol. 57 (2012) 7395 7407 PHYSICS IN MEDICINE AND BIOLOGY doi:10.1088/0031-9155/57/22/7395 Experimental investigation of a general real-time 3D target localization method using

More information

Mixed-Reality for Intuitive Photo-Realistic 3D-Model Generation

Mixed-Reality for Intuitive Photo-Realistic 3D-Model Generation Mixed-Reality for Intuitive Photo-Realistic 3D-Model Generation Wolfgang Sepp, Tim Bodenmueller, Michael Suppa, and Gerd Hirzinger DLR, Institut für Robotik und Mechatronik @ GI-Workshop VR/AR 2009 Folie

More information

Complex Sensors: Cameras, Visual Sensing. The Robotics Primer (Ch. 9) ECE 497: Introduction to Mobile Robotics -Visual Sensors

Complex Sensors: Cameras, Visual Sensing. The Robotics Primer (Ch. 9) ECE 497: Introduction to Mobile Robotics -Visual Sensors Complex Sensors: Cameras, Visual Sensing The Robotics Primer (Ch. 9) Bring your laptop and robot everyday DO NOT unplug the network cables from the desktop computers or the walls Tuesday s Quiz is on Visual

More information

Digital Image Processing Lectures 1 & 2

Digital Image Processing Lectures 1 & 2 Lectures 1 & 2, Professor Department of Electrical and Computer Engineering Colorado State University Spring 2013 Introduction to DIP The primary interest in transmitting and handling images in digital

More information

ISO ISO ISO OHSAS ISO

ISO ISO ISO OHSAS ISO ISO 9001 ISO 13485 ISO 14001 OHSAS 18001 ISO 27001 Pro-NM Performance 08-101 - standard version 08-103 - version with the PET Lid Phantom for NM and PET systems performance evaluation (collimator, artifacts,

More information

TYPES OF CAMERAS IN CCTV

TYPES OF CAMERAS IN CCTV TYPES OF CAMERAS IN CCTV 1. FIXED AND PTZ CAMERAS: CCTV cameras can be fixed, have pan, tilt and can have zoom capabilities. Fixed cameras are mounted on fixed brackets and cannot move. PTZ cameras are

More information

Z-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL

Z-MOTION. Universal Digital Radiographic System Z-MOTION. Control-X Medical CONTROL-X MEDICAL Control-X Medical Z-MOTION Compact design, low ceiling height requirement Motorized and manual movement capability Wide motion / SID range Best-in-class image quality Flexible connectivity to PACS systems

More information

Binocular stereo. Given a calibrated binocular stereo pair, fuse it to produce a depth image. Where does the depth information come from?

Binocular stereo. Given a calibrated binocular stereo pair, fuse it to produce a depth image. Where does the depth information come from? Binocular Stereo Binocular stereo Given a calibrated binocular stereo pair, fuse it to produce a depth image Where does the depth information come from? Binocular stereo Given a calibrated binocular stereo

More information

Introduction to 3D Machine Vision

Introduction to 3D Machine Vision Introduction to 3D Machine Vision 1 Many methods for 3D machine vision Use Triangulation (Geometry) to Determine the Depth of an Object By Different Methods: Single Line Laser Scan Stereo Triangulation

More information

Development of a novel laser range scanner

Development of a novel laser range scanner Development of a novel laser range scanner Thomas S. Pheiffer a, Brian Lennon b, Amber L. Simpson a, Michael I. Miga a a Vanderbilt University, Department of Biomedical Engineering, Nashville, TN 37235

More information

3D Time-of-Flight Image Sensor Solutions for Mobile Devices

3D Time-of-Flight Image Sensor Solutions for Mobile Devices 3D Time-of-Flight Image Sensor Solutions for Mobile Devices SEMICON Europa 2015 Imaging Conference Bernd Buxbaum 2015 pmdtechnologies gmbh c o n f i d e n t i a l Content Introduction Motivation for 3D

More information

Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD

Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT. AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD Image Quality Assessment and Quality Assurance of Advanced Imaging Systems for IGRT AAPM Penn-Ohio Chapter Sep 25, 2015 Soyoung Lee, PhD 1 Outline q Introduction q Imaging performances in 4D-CBCT Image

More information

3D Surface Imaging for PBI Patient Setup

3D Surface Imaging for PBI Patient Setup 3D Surface Imaging for PBI Patient Setup G.T.Y. Chen 1, Ph.D., M. Riboldi 2, Ph.D. Christoph Bert 3, Ph.D., D.P. Gierga 1, Ph.D. 1 Massachusetts General Hospital Harvard Medical School 2 TBMLab - Department

More information

xorantech.com Suite of DR Products

xorantech.com Suite of DR Products xorantech.com Suite of DR Products 2 / xorantech.com Xoran provides unsurpassed, white-glove customer service and high quality, reliable products that are user- and patient-friendly Xoran is the pioneer

More information

Measurement of inter and intra fraction organ motion in radiotherapy using cone-beam CT projection images

Measurement of inter and intra fraction organ motion in radiotherapy using cone-beam CT projection images Measurement of inter and intra fraction organ motion in radiotherapy using cone-beam CT projection images T E Marchant, A M Amer 1 and C J Moore North Western Medical Physics, Christie Hospital NHS Foundation

More information

7/31/ D Cone-Beam CT: Developments and Applications. Disclosure. Outline. I have received research funding from NIH and Varian Medical System.

7/31/ D Cone-Beam CT: Developments and Applications. Disclosure. Outline. I have received research funding from NIH and Varian Medical System. 4D Cone-Beam CT: Developments and Applications Lei Ren, PhD, DABR Department of Radiation Oncology Duke University Medical Center Disclosure I have received research funding from NIH and Varian Medical

More information

Respiratory Motion Estimation using a 3D Diaphragm Model

Respiratory Motion Estimation using a 3D Diaphragm Model Respiratory Motion Estimation using a 3D Diaphragm Model Marco Bögel 1,2, Christian Riess 1,2, Andreas Maier 1, Joachim Hornegger 1, Rebecca Fahrig 2 1 Pattern Recognition Lab, FAU Erlangen-Nürnberg 2

More information

Overview of Proposed TG-132 Recommendations

Overview of Proposed TG-132 Recommendations Overview of Proposed TG-132 Recommendations Kristy K Brock, Ph.D., DABR Associate Professor Department of Radiation Oncology, University of Michigan Chair, AAPM TG 132: Image Registration and Fusion Conflict

More information

Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI

Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems. Bruce Curran University of Michigan Medical Center Ann Arbor, MI Acceptance Testing and Commissioning of Monte Carlo Dose Calculation Systems Bruce Curran University of Michigan Medical Center Ann Arbor, MI Disclosure Some of the work discussed in this talk was supported

More information

STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION

STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION STRAIGHT LINE REFERENCE SYSTEM STATUS REPORT ON POISSON SYSTEM CALIBRATION C. Schwalm, DESY, Hamburg, Germany Abstract For the Alignment of the European XFEL, a Straight Line Reference System will be used

More information

Project 2 due today Project 3 out today. Readings Szeliski, Chapter 10 (through 10.5)

Project 2 due today Project 3 out today. Readings Szeliski, Chapter 10 (through 10.5) Announcements Stereo Project 2 due today Project 3 out today Single image stereogram, by Niklas Een Readings Szeliski, Chapter 10 (through 10.5) Public Library, Stereoscopic Looking Room, Chicago, by Phillips,

More information

Centralite CT Moving Laser Patient Positioning System (MRR-1)

Centralite CT Moving Laser Patient Positioning System (MRR-1) Centralite CT Moving Laser Patient Positioning System (MRR-1) Installation and Setup Manual DIACOR, INC. 2550 DECKER LAKE BLVD., SUITE 26, WEST VALLEY CITY, UTAH 84119 800 342-2679 / 801 467-0050 / 801

More information

DICOM Conformance Statement ExacTrac 6.2 Document Revision 3 July 6, Copyright Brainlab AG

DICOM Conformance Statement ExacTrac 6.2 Document Revision 3 July 6, Copyright Brainlab AG Document Revision 3 July 6, 2016 2016 Copyright Brainlab AG 1 Conformance Statement Overview This is a conformance statement for the Brainlab software ExacTrac. The DICOM import part of the application

More information

X-ray Target Reconstruction for Cyber Knife Radiosurgery Assignment for CISC/CMPE 330

X-ray Target Reconstruction for Cyber Knife Radiosurgery Assignment for CISC/CMPE 330 X-ray Target Reconstruction for Cyber Knife Radiosurgery Assignment for CISC/CMPE 330 We will perform radiosurgery of multipole liver tumors under X-ray guidance with the Cyber Knife (CK) system. The patient

More information

An Endoscope With 2 DOFs Steering of Coaxial Nd:YAG Laser Beam for Fetal Surgery [Yamanaka et al. 2010, IEEE trans on Mechatronics]

An Endoscope With 2 DOFs Steering of Coaxial Nd:YAG Laser Beam for Fetal Surgery [Yamanaka et al. 2010, IEEE trans on Mechatronics] An Endoscope With 2 DOFs Steering of Coaxial Nd:YAG Laser Beam for Fetal Surgery [Yamanaka et al. 2010, IEEE trans on Mechatronics] GEORGE DWYER Automatic Tracking Algorithm in Coaxial Near-infrared Laser

More information

System Integration and Preliminary In-Vivo Experiments of a Robot for Ultrasound Guidance and Monitoring during Radiotherapy

System Integration and Preliminary In-Vivo Experiments of a Robot for Ultrasound Guidance and Monitoring during Radiotherapy System Integration and Preliminary In-Vivo Experiments of a Robot for Ultrasound Guidance and Monitoring during Radiotherapy H. Tutkun Şen, Muyinatu A. Lediju Bell, Yin Zhang, Kai Ding, John Wong, Iulian

More information

Code of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³

Code of practice: Create a verification plan for OCTAVIUS Detector 729 in Philips Pinnacle³ Technical Note D655.208.03/00 Code of practice: Create a verification plan for OCTAVIUS Detector 729 in There are basically three ways to carry out verification of IMRT fluences. For all options, it is

More information