Lossnay Energy Recovery Ventilator

Size: px
Start display at page:

Download "Lossnay Energy Recovery Ventilator"

Transcription

1 Energy Recovery Ventilator MODELS: LGH-5RVX-E, LGH-5RVX-E, LGH-35RVX-E LGH-5RVX-E, LGH-65RVX-E, LGH-8RVX-E LGH-RVX-E, LGH-5RVX-E, LGH-RVX-E Installation Instructions (For use by dealer/contractor) English Models LGH-5 to RVX-E Models LGH-5 and RVX-E Contents Safety precautions... Outline drawings...3 Standard installation examples...4 Installation method...4 Function settings...3 Check points after installation work... Trial operation... This product needs to be installed properly in order to ensure maximum functionality as well as safety. Please make sure to read this installation manual before starting the installation. Installation must be performed by a dealer or installation contractor. Please note that improper installation may cause malfunction or accident. Operating Instructions and this manual must be handed over to the customer after completing the installation. Safety precautions The following signs indicate that death or serious injury may be caused by failure to heed the precautions described below. WARNING Do not disassemble Prohibition of use in bath or shower room Connect the grounding wire. The instructions given must be followed. Do not modify or disassemble. (It could cause fire, electric shock or injury.) The unit and remote controller should not be installed where it is highly humid, like a bathroom, or other wet place. (It could cause electric shock or power leakage.) Connect the product properly to ground. (Malfunctioning or power leaks can cause electrical shock.) Use the specified power supply and voltage. (Use of incorrect power supply or voltage could cause fire or electric shock.) Select a place with sufficient strength and install the main unit securely. (It could cause injury if it falls.) The instructions given must be followed. Wiring work must be performed by qualified professionals, and be implemented safely and securely in accordance with the engineering standards and the extension wiring rules for electrical equipment. (Poor connection or improper wiring work could cause electric shock or fire.) Install a power supply isolator at the power supply side as per local electrical regulations. All supply circuits must be disconnected before obtaining access to the terminal devices. Use the specified cable size and connect the cables securely to prevent disconnection when they are pulled. (If there is a defect in the connection, there is a possibility of fire.) Select an adequate place for the opening to introduce outdoor air, where it will not intake the exhaust fumes like combustion gas, or others, and there is no risk of blockage. (Shortage of fresh air could put the room in a state of oxygen deficiency.) A duct made of steel must be installed with care not to be connected electrically with metal, wire, stainless steel plate, or others. (It could cause fire when power leakage occurs.) Eng-

2 Safety precautions (continued) Prohibited The instructions given must be followed. Do not place a burning appliance in a place where it is exposed directly to the air from the unit. (It could cause an accident as a result of incomplete combustion.) Do not use at a place where it is exposed to high temperatures (4 C or higher), naked flames, or in environment with combustible fumes. (It could cause fire.) Do not use in an environment such as a chemical factory, where hazardous gases such as acidic gases, alkaline gases, organic solvent fumes, paint fumes, or gases containing corrosive components are generated. (It could malfunction.) Do not install this product in a place where it is exposed to ultraviolet light. (UV may damage covering insulation.) Put on gloves during installation. (It could cause injury.) Make sure the power supply isolator is turned off on the power distribution panel when is not used for a long period of time after the installation. (It could cause electric shock, power leakage, or fire as a result of deteriorated insulation.) Always use the specified suspension bolts, nuts and washers or correctly rated wire / chain hangers. (Use of hardware with insufficient strength could result in the product dropping.) The outside ducts must be tilted at a gradient (/3 or more) down toward the outdoor louvres from, and properly insulated. (The entry of rain water may cause power leakage, fire, or damage to household property.) The instructions given must be followed. The control box cover must be closed after the installation. (Dust or humidity may cause power leakage or fire.) When connecting external devices (electric heater, damper, lamp, monitoring unit, etc.) using output signals of the unit, make sure to install safety equipment for the external devices. (It could cause fire, damage, etc. without safety equipment.) Select a duct heater in compliance with local and national laws, ordinances, and standards. Select a duct heater that has obtained the CE mark. Install the duct heater separated from the product by a distance of m or more. (Failure to do so may result in fire or equipment damage due to the transmission of residual heat from the heater.) This appliance is not intended for use by persons (including children) with reduced physical sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. Children should be supervised to ensure that they do not play with the appliance. (This appliance can be used by children aged from 8 years and above and persons with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance shall not be made by children without supervision.) When using the product where it is exposed to high temperatures and humidity (4 C or higher, RH 8% or higher), or where fog occurs frequently, moisture is likely to condense in the core, and may result in condensation build up in the unit. The product should not be used under such conditions. Outdoor air may enter the owing to the pressure difference between indoor and outdoor or external winds even when the product is not operated. It is recommended to install an Electrically operated damper to block the outdoor air. In a cold weather area, an area with strong external winds or where fog occurs frequently, cold outdoor air, external winds or fog may be introduced into the product when its operation is stopped. It is recommended to install an Electrically operated damper. When using the product in an environment where there is a window, or opening near the outdoor louvre, where insects are likely to gather around the interior or exterior light, take note that small insects may intrude into the product. In a cold weather area, or others, dewing or freezing could occur on the main unit, where the duct is connected, or other sections, depending on the conditions of outdoor air and indoor temperature and moisture, even if they are within the range of operating conditions. Make sure to confirm the operating conditions and other precautions, and do not use the product if dewing or freezing is anticipated. *Example of dewing condition - Outdoor air: -5 C or lower, dew-point temperature at installation place: C or higher (When the indoor temperature is C or higher with the relative humidity higher than 5%, or other) Eng-

3 Outline drawings LGH-5 to RVX-E Position where duct direction change is possible M By-pass damper plate Air exhaust fan D Ceiling suspension fixture (4-3 X oval) F Accessory parts Mounting screws 4-8 for duct flanges...x6 English EA (exhaust air outlet) B K L E RA (return air) Mounting screws M5- for ceiling suspension fixture...x4 Duct connecting flanges...x4 OA (outside air intake) SA (supply air) 5 Core, air filter,high- Efficiency filter, fan, maintenance space More than 6 5 to 5 J M Inspection opening 45 x 45 or more Air supply fan Control box Maintenance cover core High-Efficiency filter (sold separately) attachment position A J F N C Power supply cable opening Screw cap...x6 Slim- connection cable (gray: two wires)...x A B C D N G H Position where duct direction change is possible Air filters Unit (mm) Dimensions Ceiling suspension fixture pitch Model Nominal Duct connecting flange Duct pitch Weight A B C D E F diameter G H J K L M N (kg) LGH-5RVX-E LGH-5RVX-E LGH-35RVX-E LGH-5RVX-E LGH-65RVX-E LGH-8RVX-E LGH-RVX-E LGH-5 and RVX-E EA (exhaust air outlet) Air exhaust fan 7 By-pass damper plate Ceiling suspension fixture (4-5 x 3 oval) RA (return air) 4 4 Accessory parts Mounting screws 4-8 for duct flanges...x6 Duct connecting flanges...x4 OA (outside air intake) 7 SA (supply air) Screw cap...x6 Core, air filter, High-Efficiency filter, fan, maintenance space More than 6 5 to 5 cores Inspection opening 45 x 45 or more 6 Air supply fan Control box Maintenance cover High-Efficiency filter (sold separately) attachment position Power supply cable opening Slim- connection cable (gray: two wires)...x Air filters ø4 ø58 ø4 ø58 Unit (mm) Model A B C D Weight (kg) LGH-5RVX-E LGH-RVX-E Eng-3

4 Standard installation examples Duct length Model LGH-5 to 65RVX-E LGH-8 and RVX-E LGH-5 and RVX-E Distance m or more.5 m or more 3 m or more The parts can also be installed upside down. Remove the maintenance cover, rotate the parts by 8, and re-install. OA (outside air intake) EA (exhaust air outlet) * It can be installed by inverting the top and the bottom. Maintenance space Inspection opening unit After installing the duct connecting flange, remove the maintenance cover. Turn the cover by 8, and then reinstall it. EA (exhaust air outlet) OA (outside air intake) Downward gradient of duct: /3 or more (toward wall side) and provision of distance in table below (to prevent rain water from seeping in) Duct * Except the 5 and RVX-E. unit Return air grille (not Included) Maintenance space Inspection opening Anchor bolt (to be provided by user) Supply air grille (not included) EA (exhaust air outlet) OA (outside air intake) EA (exhaust air outlet) OA (outside air intake) Electrically operated damper (Protection against the intrusion of cold air while is stopped in winter) (To be provided by the customer) unit Deep hood (to prevent rain water from seeping in) In a region where there is risk of freezing in winter, it is recommended to install an Electrically operated damper, or the like, in order to prevent the intrusion of (cold) outdoor air while is stopped. OA (outside air intake) EA (exhaust air outlet) unit Inspection opening (45x45 or more) Remote controller (optional parts) Supply air grille (not included) SA RA (supply air) (return air) Do not install unit vertically or on an incline. Return air grille (not included) Installation method Installing the unit. Attaching the duct connecting flanges Use the supplied screws (size:4-8) to secure the duct connecting flanges to the unit. Models LGH-5 to RVX-E Before attaching the duct connecting flanges, that no foreign matter (scraps of paper, vinyl, etc.) has found its way inside to unit. Attach the duct connecting flanges with the packing at the SA and RA sides. Duct connecting flange (Accessory parts) Models LGH-5 and RVX-E Mounting screw (size:4-8) (Accessory parts) Mounting screw (size: 4-8) (Accessory parts). Securing the ceiling suspension fixtures Models LGH-5 to RVX-E () Loosen the screws for the ceiling suspension fixtures. () Rotate the ceiling suspension fixtures 9 centered around the loosened screws to make them horizontal. (3) Firmly tighten and secure the ceiling suspension fixtures to the product with the loosened screws and the included mounting screws (M5-). * The ceiling suspension fixtures are folded and secured to the unit when shipped from the factory. Loosen Mounting screw (size: 5-) (Accessory parts) Eng-4 Duct connecting flange (Accessory parts)

5 Installation method (continued) 3. Preparing the anchor bolts Mount the washers (outer diameter of > mm for M, >4 mm for M) and nuts onto the pre-recessed anchor bolts (M or M), as shown in the figure below. Anchor bolt (M or M) Nut Washer Nut USE TWO NUTS [When using (customer-prepared) vibration isolation rubber] When using (customer-prepared) vibration isolation rubber, there is a possibility of this causing a decrease in strength, so we recommend the following type of construction. 5. Connecting the ducts () Fasten the duct securely to the duct connecting flange, and wrap aluminium tape (field supply) around the joints so that there is no air leakage. () Suspend the ducts from the ceiling so that their weight will not be applied to the unit. (3) The two outdoor ducts must be covered with heat-insulating material in order to prevent condensation from forming. Models LGH-5 to RVX-E Room Side Duct English Anchor bolt (M or M) Nut Washer Heat-insulating material Aluminium tape Vibration isolation rubber Nut USE TWO NUTS Outdoor Side Taping Outdoor duct Duct connecting flange unit 4. Mounting unit () Hang the ceiling suspension fixtures on the anchor bolts and adjust in such a way that unit is level. () Tighten up securely using double nuts. Models LGH-5 and RVX-E Heat-insulating material Taping Duct Room Side Models LGH-5 to RVX-E Anchor bolt Ceiling suspension fixture Aluminium tape Outdoor Side Duct connecting flange Heat-insulating material Washer Nut Nut Washer Ceiling suspension fixture Washer Nut Models LGH-5 and RVX-E Anchor bolt (M or M) When suspending unit from the ceiling, do not handle it in such a way that force will be applied to the control box. Install the anchor bolts to ensure the product's weight or earthquake load. (Correctly rated wire/chain may also be used) Outdoor duct Duct connecting flange unit When on-site commissioning is planned, a straight duct length more than xd (D=duct diameter) from the source of turbulence like bends, contractions and dampers etc, to the measurement point is recommended for correct measurement. In the United Kingdam, on-site measurment should therefore be measured in accordance with BSRIA guideline (Commissioning Air System. Application procedures for buildings AG3/89.3()) Before attaching the ducts, that no (debris or any other) foreign matter (scraps of paper, vinyl, etc.) has found its way inside the ducts. Do not touch the damper plate inside unit when connecting the ducts. If it is expected that the ambient temperature around the place where the unit is installed will be high during the summer air conditioning season, it is recommended that the indoor duct work be covered with insulation material. Do not carry out the following types of duct construction. (Doing so could cause a drop in the air volume and generate abnormal noises.) Extremely sharp bends Multiple bends Bends right next to the outlet Extreme reduction in the diameter of the connected ducts Eng-5

6 Installation method (continued) 6. When changing the direction of the out door side duct (EA/OA) Except for LGH-5 and RVX-E () Removal of flange cover Unscrewing the flange cover mounting screws (4 pcs), remove the flange cover. Flange cover Ceiling suspension fixture Electrical installation With this product, the wiring installation method will vary according to the design of the system. Perform electrical installation to meet local electrical regulations. * Always use double insulated PVC cable for the transmission cables. * Wiring work must be performed by qualified professionals. * All supply circuits must be disconnected before obtaining access to the terminal devices. Names of components in control box Mounting screw (for flange cover) () Installation of duct connecting flange. Install the duct connecting flange using attached mounting screws.. Fix the removed flange cover with the removed mounting screws (4 pcs). Ceiling suspension fixture Duct connection flange TM3 TM4 TB5 TM LED3 LED,, 4 SW, SW5 SA, SA Mounting screw (Accessory parts) TM Eng-6

7 Installation method (continued) Wire connection diagram Model LGH-5 to RVX-E * TM, TM, TM3, TM4, TB5 shown in dotted lines are field work. * Be sure to connect the ground wire. * A power supply isolator must be installed. * Always use an isolator for the main switch power connection. English By-pass monitor or Preheater signal output (*) (*) MAX 4 VAC A MIN VAC ma 4 VDC A 5 VDC ma REACTOR Malfunction monitor output (*) Exhaust or Supply fan monitor output (*) COM TM3 CN6 CN3 M EXHAUST FAN MOTOR CN9 TAB3,4 LED6 Lower Printed Circuit Board PZ- 6DR-E nd remote controller (Max. controllers) nd unit (Max. 5 units) M-NETtransmission cable X5 X4 X3 A B TM4 TB5 CN7 LED3 Upper Printed Circuit Board LED4 LED LED M SUPPLY FAN MOTOR CN CN9 Uncharged A-contact Shielded Wire V or 4V DC Mr.Slim (non-polar) S 3 TM SASA SW SW5 CN8 CN9 CN8 GM CN7 TAB5 TABTAB CN5 CN TH(RA) TH(OA) Isolator (Field supply) LINE FILTER L N PE TM L N POWER SUPPLY -4 V / 5Hz V / 6Hz M: Motor for exhaust fan M: Motor for supply fan GM: Motor for By-pass damper TH: Thermistor for outside air TH: Thermistor for return air SW,5: Switch (Function selection) TM: Terminal block (Power supply) TM: Terminal block (External control input) TM3: Terminal block (Monitor output) TM4: Terminal block (Transmission cable) TB5: Terminal block (M-NET Transmission cable) TAB, TAB, (TAB5): Connector (Power supply) TAB3,TAB4: Connector (Reactor) Definition of symbols X3: Relay contact X4: Relay contact X5: Relay contact CN5: Connector (Thermistor RA) CN7: Connector (Motor for By-pass damper) CN9: Connector (Fan motor) CN: Connector (Fan motor) CN7: Connector (Fan speed //3/4) CN8: Connector CN8: Connector CN9: Connector CN9: Connector CN: Connector (Thermistor OA) CN6: Connector (By-pass, - VDC Fan speed control) CN3: Connector (Remote control selection) SA: Address setting rotary switch ( digit) SA: Address setting rotary switch ( digit) LED to LED3: Inspection indicator lamp LED4, LED6: Power supply indicator lamp SYMBOL : Terminal block : Connector on PCB Eng-7

8 Installation method (continued) Wire connection diagram Models LGH-5 and RVX-E * TM, TM, TM3, TM4, TB5 shown in dotted lines are field work. * Be sure to connect the ground wire. * A power supply isolator must be installed. * Always use an isolator for the main switch power connection. M EXHAUST FAN MOTOR M SUPPLY FAN MOTOR GM CN9 CN CN7 REACTOR TAB3,4 LED6 Lower Printed Circuit Board TAB CN TAB By-pass monitor or Preheater signal output (*) Malfunction monitor output (*) Exhaust or Supply fan monitor output (*) PZ- 6DR-E nd remote controller (Max. controllers) nd unit (Max. 5 units) M-NETtransmission cable Uncharged A-contact COM Shielded Wire V or 4V DC Mr.Slim (non-polar) (*) MAX 4 VAC A MIN VAC ma 4 VDC A 5 VDC ma X5 X4 X3 A B S 3 TM3 TM4 TB5 TM SASA CN6 CN3 CN7 LED3 Upper Printed Circuit Board LED4 LED LED SW SW5 CN REACTOR CN9 CN8 M EXHAUST FAN MOTOR TAB3,4 CN9 LED6 Lower Printed Circuit Board TH(RA) CN5 CN TH(OA) M SUPPLY FAN MOTOR GM CN CN7 TAB5 CN9 CN8 TAB TAB LINE FILTER L N PE TM Isolator (Field supply) L N POWER SUPPLY -4 V / 5Hz V / 6Hz M: Motor for exhaust fan M: Motor for supply fan GM: Motor for By-pass damper TH: Thermistor for outside air TH: Thermistor for return air SW, 5: Switch (Function selection) TM: Terminal block (Power supply) TM: Terminal block (External control input) TM3: Terminal block (Monitor output) TM4: Terminal block (Transmission cable) TB5: Terminal block (M-NET Transmission cable) TAB, TAB, TAB5: Connector (Power supply) TAB3, TAB4: Connector (Reactor) Definition of symbols X3: Relay contact X4: Relay contact X5: Relay contact CN5: Connector (Thermistor RA) CN7: Connector (Motor for By-pass damper) CN9: Connector (Fan motor) CN: Connector (Fan motor) CN7: Connector (Fan speed //3/4) CN8: Connector CN8: Connector CN9: Connector CN9: Connector CN: Connector CN: Connector CN: Connector (Thermistor OA) CN6: Connector (By-pass, - VDC Fan speed control) CN3: Connector (Remote control selection) SA: Address setting rotary switch ( digit) SA: Address setting rotary switch ( digit) LED to LED3: Inspection indicator lamp LED4, LED6: Power supply indicator lamp SYMBOL : Terminal block : Connector on PCB Eng-8

9 Installation method (continued) Connecting the power supply cable. Remove the black screws and the control box cover LGH-5 to RVX-E Control box cover Black screws LGH-5 and RVX-E Control box cover The following system configuration can be created. Connect the necessary parts. When connecting with remote controller (PZ-6DR-E). When interlocked with indoor unit of air conditioner or other external device including other manufactures. 3 When operating multiple units. 4 By-pass monitor or Pre-heater signal output. 5 Malfunction monitor output. 6 Operation monitor output 7 When switching fan speed externally (when a sensor or other device is connected). 8 When switching By-pass externally. 9 To change fan speed by - VDC input When using the remote/local switching and the ON/ input (level signal) When connecting to the City Multi or Mitsubishi Electric Air- Conditioner Network System (MELANS). To start/stop stand-alone operation without using the remote control English Black screws. Attach the screw cap. Models LGH-5 to RVX-E Models LGH-5 and RVX-E When connecting external devices (electric heater, damper, lamp, monitoring unit, etc.) using output signals of the unit, make sure to install safety equipment for the external devices. (It could cause fire, damage, etc. without safety equipment.) When connecting with remote controller (PZ-6DR-E) Screw Screw cap After installing the unit, attach the supplied screw caps to the screws at the bottom of the unit. 3. Connecting the power supply cable and transmission cable Pass the Power supply cable through the bush* and connect to the TM terminal block using the round terminals. Connect the ground wire to the ground terminal and secure tightening the bush. (* Use an item that can firmly secure the cable such as a PG connector.) Insert the cutting Bush Screw Screw cap * When controlling units with MELANS, connect wires according to. Securely connect the transmission cable from the remote controller to and of the input terminal block (TM4). (No polarity) Wire type: two-core sheathed cable Wire diameter:.3 mm If there are two remote controllers, connect them in the same way. Keep the overall length of the transmission cable between and the remote controller within m. Note Do not tighten screws of terminal block with a torque larger than.5 Nm. It could damage the PCB. Take care not to connect the power supply cable or M-NET transmission cable. Number of transmission cables which can be connected to single input terminal is up to 4 wires. Single wires such as PVC wires cannot be connected. PG connector Cord clip Transmission cable TM Power supply cable Power supply Up to two remote controllers Ground wire Power supply cable Always separate the power supply cable and transmission cable by 5 cm or more to prevent malfunctioning of the unit. If the length of the stripped Power supply cable is too long, the conductors may touch and short out. Power supply cable size :.5 mm (ø9)or more. () Tighten the ground wire and transmission cables to the terminal block. () Secure the transmission cables using the cord clips. Upon completion of the wiring connections, replace the control box cover. Remote controller input terminal Transmission cables Eng-9

10 Installation method (continued) When interlocked with indoor unit of air conditioner or other external device including other manufactures The connection may vary according to the output signal type of the external unit. Don t tighten screws of terminal block with a torque larger than.5 Nm. It could damage the PCB. When the external device has an uncharged a-contact signal The wiring should be the following picture. external control input (TM) Maximum 5 m.5 mm to.5 mm sheathed PVC cable External device Uncharge a-contact Power supply TM External device Power supply Operating switch for external device If an optocoupler or any other type of polar coupler is used at the uncharged a-contact, connect the positive side to 3 and the negative side to. When using Mitsubishi Mr. Slim air conditioner with MA Remote controller Confirm that the pulse input switch (SW-) is set to. (Factory setting is.) (Refer to function settings No. 8 ) Connect the interlocking cable connector side to CNL on the circuit board for the Mr. Slim indoor unit, then connect the lead wire side to the and of the input terminal block (TM) for the external controller input. (No polarity) Always separate the power supply cable and the Slim- connection cable by 5 cm or more to prevent the unit from malfunctioning. The Slim- connection cable is mm long. When wiring, extend it as far as necessary. 3 When operating multiple units ) Connect from Unit to Unit, and from Unit to Unit 3 and so on up to a maximum of 5 units using a transmission cable. Wire type: two-core sheathed cable Wire diameter:.3 mm ) When it is interlocked with an external device, turn ON the setting switch (SW5-) of main where the external signal is input. external control input (TM) Slim- connection cable (Accessory parts) CNL Remote controller (PZ-6DR-E) Mr. Slim (Indoor unit) Power supply ON Maximum 5 m Printed circuit board Note The remote controller (PZ-6DR-E) cannot be used with this system. Use MA remote controller of Mr. Slim for switching ON/ or the fan speed. The ventilation mode is automatic ventilation. Ensure that all connections are secure and that the appropriate insulation is provided. Use extension cable sheathed PVC cable or cable.5 mm to.5 mm. When the external device has a charged operating signal of VDC or 4 VDC [SW-] setting vary depending on the types of output signal of external device. Move the pulse input switch [SW-] to the ON position. (Refer to function settings No. 8 ) When interlocking with a pulse output device, a pulse width is at least m sec. to turn ON, and sec. interval is necessary to next output. The wiring should be the following picture. external control input (TM).5 mm to.5 mm sheathed PVC cable External device Power supply Power supply MAX 5 units TM4 TM4 First Second Transmission cable Connect to remote controller (PZ-6DR-E) Connect to third Don t tighten screws of terminal block with a torque larger than.5 Nm. It could damage the PCB. Note Up to four transmission cables can be connected to one input terminal. Single wires such as PVC wires cannot be connected. Only one unit can be set as main. The operating signal and pulse signal of the external device can be connected to main only. When the external signal is not input, main-unit setting is not required even for operation of multiple units. Connect the power supply cable to each unit. SW ON or 4 VDC Overall connection extension length (Follow the operation manual for the external equipment.) Eng-

11 Installation method (continued) 4 By-pass monitor or Pre-heater signal output. By-pass monitor or Pre-heater signal can be selected at SW5-6. (Refer to function settings No. 58 ) Always that it is the intended setting. By-pass monitor SW5-6 By-pass operation indicator Max Min Pre-heater output SW5-6 ON m or more Pre-heater 4 VAC, A 4 VDC, A VAC, ma 5 VDC, ma Power Supply for heater Relay Power Supply Power Supply for relay Select a duct heater in compliance with local and national laws, ordinances, and standards. Select a duct heater that has obtained the CE mark. Always select a heater that is equipped with a non-selfresetting safety device. Do not directly supply power from the unit to the duct heater. (Doing so could cause fire.) Install a circuit breaker for the duct heater in compliance with all applicable laws, ordinances, and standards. Install the duct heater separated from the product by a distance of m or more. (Failure to do so may result in equipment damage due to the transmission of residual heat from the heater.) When using a heater without a temperature control function, select a heater with a capacity that is matched to the air volume. Do not use the heater outside the set air volume. (If the heater s capacity is too larger, this may result in the heater frequently turning ON/.) (If the heater s capacity is too small, this may result an inability to heat.) Ensure that the duct heater and are wired and that the function settings have been configured, and then always operation by trial operation. For the duct heater output, see function setting SW OA Malfunction monitor output. Malfunction indicator Power Supply TM3 Max 4 VAC, A 4 VDC, A Min VAC, ma 5 VDC, ma TM3 TM3 Max 4 VAC, A 4 VDC, A Min VAC, ma 5 VDC, ma X4 SA X3 X3 6 Operation monitor output Operation monitor output can be selected to sympathize with exhaust fan or supply fan at SW 5-. SW5- : Exhaust fan operation monitor output SW5- ON: Supply fan operation monitor output (Refer to function settings No. 57 ) Always that it is the intended setting. Operation indicator TM3 Power Supply Max 4 VAC, A 4 VDC, A Min VAC, ma 5 VDC, ma To use operation monitor output for a supply after-heater, turn SW-8 ON, and use the supply fan operation monitor output with delayed operation. (Refer to function settings No. 57 ) For the heater, observe the cautions listed in 4. 7 OA SW m or more SA TM3 Relay Power Supply for heater Power Supply Max for relay Min 4 VAC, A 4 VDC, A VAC, ma 5 VDC, ma When switching fan speed externally (when a sensor or other equipment is connected) Using a field supply sensor, etc., make connection by inserting the optional remote display adaptor (PAC-SA88HA-E) in the connector CN7 (Red) as shown by the figure. will operate the fan speed following the table below, regardless of the remote controller setting. CN7 (Red) Fan speed - (Brown-Red) 4-3 (Brown-Orange) 3-4 (Brown-Yellow) -5 (Brown-Green) Example Fan speed 4 Field supply sensor, etc. Remote display adaptor (Optional) PAC-SA88HA-E Brown Red Orange 3 Yellow 4 Green 5 Not used. Insulate completely. Max wiring length m control board Use this in such a way that it ventilates at low fan speed normally, and when the external sensor detects contamination of indoor air, it changes to high fan speed operation. X5 CN7 Fan speed selection X5 English Eng-

12 Installation method (continued) 8 9 When switching By-pass externally. Establish the wire connection by inserting the optional remote display adaptor (PAC-SA88HA-E) in the connector CN6 (White). SW With SW is ON, the ventilation mode of is changed to the By-pass ventilation regardless of the setting on the remote controller. * When the outdoor air temperature drops lower than 8 C, it changes to the heat exchanger ventilation. (Display of the remote controller does not change.) To change fan speed by - VDC input Establish the wire connection by inserting the optional remote display adaptor (PAC-SA88HA-E) in the connector CN6 (White). To change fan speed by - VDC input, the wiring should be the above picture. Refer to function settings No. 63 for more details. SW: By-pass ventilation operation switch (When closed: For By-pass ventilation operation) Not used. Insulate completely. External device CN6 CN6 When using the remote/local switching and the ON/ input (level signal) Insert the optional remote ON/ adaptor (PAC-SE55RA-E) in CN3 on the control PCB. SW SW Remote display adaptor (Optional) PAC-SA88HA-E Brown Red Orange 3 Yellow 4 ( - VDC) Green 5 (COM) Max wiring length m Make sure of correct polarity. Remote control board Relay power supply Relay circuit X Y X Y Remote display adaptor (Optional) PAC-SA88HA-E Brown Red Orange 3 Yellow 4 Green 5 Not used. Insulate completely. Max wiring length m control board Fan speed/ Ventilation mode selection Max wiring length m SW: When this is ON, cannot turn ON/ by the Remote Controller (PZ-6DR-E). SW: When SW is ON, can be turned ON by setting SW at ON or turned by setting SW at. SW: Remote/local selector switch SW: ON/ switch X, Y : Relay (Contactor rating DC ma) control board Fan speed/ Ventilation mode selection Remote ON/ adaptor (Optional) PAC-SE55RA-E control board Orange Red Brown 3 CN3 When connecting to the City Multi, Mitsubishi Electric Air- Conditioner Network System (MELANS) M-NET transmission cable Shielded wire TB5 A B S M-NET transmission cable input terminal block One shielded wire is connected to terminal TB5 S on the PCB. Address setting is required. (Refer to function setting section.) M-NET transmission cable: Connect any of the City Multi indoor unit, or Mitsubishi Electric Air- Conditioner Network System (MELANS) - to the. Remote Controller PZ-6DR-E: Connect to TM4, on the PCB. (See Section When connecting with Remote Controller (PZ-6DR-E).) Securely connect the M-NET transmission cables to TB5 AB. (No-Polar) Type: (Shielded wire, CVVS/CPEVS) Wire diameter:.5 mm to. mm Don t tighten screws on the terminal block with a torque larger than.5 Nm. It may damage the PCB. Always use shielded wires only for the M-NET transmission cables, and finish the shield properly. When interlocking with Mitsubishi M-NET air conditioner Incase of PZ-6DR-E Air conditioner MA remote controller Power supply unit Air conditioner M-NET transmission cable PZ-6DR-E When connecting to PZ-6DR-E and MELANS Connect the power feeding unit. (Optional) MELANS M-NET transmission cable PZ-6DR-E * Limit the total length of transmission cables no longer than 5 m. Limit the wiring length between and the power supply unit (Optional) or the outdoor unit no longer than m. To start/stop stand-alone operation without using the remote control TM L N PE Isolator TM external control input Switch Start/stop the unit by a switch connected to TM3. When turned the unit ON, it operates at fan speed 4 and automatic ventilation mode. Do not start/stop the unit by turning the power supply to the unit ON/. Eng-

13 Function settings Address setting is required when connecting to City Multi and MELANS. the address Use the following procedure when setting the address for dedicated. (The method in determining the addresses will depend on the existing system. Refer to the appropriate technical documents for details.) () Remove the control box cover. () Use a flat blade screwdriver to turn the address setting switch on the circuit board. SA indicates the digit and SA indicates the digit. The factory setting is. Change the function settings from the remote controller PZ-6DR-E. Please refer to the Instruction book of PZ-6DR-E for how to set the function settings. English SA SA digit digit Address setting switch * When the address number has been changed, the data in the memory is automatically reset. Changing the function selection switches (SW- and 5) Set the selection switches (SW- and 5) to perform the appropriate function. * All function except trial operation can be set also from the remote controller (PZ-6DR-E). If the function is switched later using the remote controller, it operates according to the setting on the remote controller (SW) ON Trial operation No. 8 Pulse input setting No. 63 External fan speed input setting ( - VDC) No. 6 Indoor negative pressure setting No. 7 Indoor positive pressure setting No. 63 External fan speed input setting ( - VDC) No. 5 Automatic ventilation mode setting No. 57 Operation monitor output synchronized with exhaust fan or supply fan No. 6 Fan speed for air volume High input No. 6 Fan speed for air volume Low input (SW5) ON No. 9 Delay start setting for air conditioner starting No. 57 Operation monitor output synchronized with exhaust fan or supply fan No. 3, No. 4 Exhaust fan setting No. 5 Automatic recovery setting after power interruption No. Filter maintenance and fan power up setting against filter choking No. 58 By-pass monitor output or Pre-heater output setting No. 5 Interlock mode setting No. 5 Interlock mode setting No. 4 Exhaust fan setting at OA temperature lower than -5 C Input setting Eng-3

14 Function settings (continued) No Function * Filter maintenance and fan power up setting against filter choking Data Indicator available Fan power up Indicator Fan power up Indicator available Fan power up available Factory setting DIP-SW No. 5-5 core maintenance indicator setting Available 5 Automatic recovery setting after power interruption 6 Indoor negative pressure setting 7 Indoor positive pressure setting Stop when the power is On Start when the power is On Supply down Exhaust down Return to the state before interruption Supply down Exhaust down Max. fan speed setting during the first 3 minutes Available 9 Delay start setting for air conditioner starting 5 min 3 min 5-3 Exhaust fan setting during air conditioner defrosting Stop No change Exhaust fan setting at OA temperature lower than -5 C 5 Interlock mode setting 8 Pulse input setting Stop ON/ interlock Non-pulse input Fan speed or ON interlock Pulse input No change interlock External input given Night-purge setting ) *3 Air volume Fan speed Fan speed Fan speed 3 Fan speed 4 - Night-purge setting ) *3 Outdoor and indoor temperature gap C C C 3 C 4 C 5 C 6 C 7 C 5 Night-purge setting 3) *3 The lowest outdoor temperature Data to 5 --> The lowest outdoor temperature for Night-purge 5 C to 3 C Main unit Individual *34 Input setting input prioritity input prior- 36 Outdoor temperature display setting Available 37 Indoor temperature display setting Available 38 Calculated supply air temperature display setting Available 39 Temperature exchange efficiency setting ( digit) Data to 9 --> digit of temperature exchange efficiency to Temperature exchange efficiency setting ( digit) Data to 9 --> digit of temperature exchange efficiency to 9 *4 Outdoor temperature correction Data to 4 --> Outdoor temperature correction -7 C to 7 C 7 *4 Indoor temperature correction Data to 4 --> Room temperature correction -7 C to 7 C 7 *5 Automatic ventilation mode setting Pattern A Pattern B Free setting -7 Automatic ventilation mode setting ) *5 Outdoor and indoor temperature gap Data to 7 --> Temperature gap C to 7 C Automatic ventilation mode setting ) *53 The lowest outdoor temperature setting Data to 5 --> Lowest outdoor temperature C to 5 C 6 Automatic ventilation mode setting 3) *54 The lowest indoor temperature setting Data to 5 --> Lowest indoor temperature 5 C to 3 C *55 Supply fan power up setting level up level up 3 level up 4 level up - *56 Exhaust fan power up setting level up level up 3 level up 4 level up Operation monitor output synchronized with exhaust fan or supply fan By-pass monitor output or Pre-heater output setting Pre-heater setting ) *59 ON temperature Pre-heater setting ) *6 interval *6 Fan speed for air volume High input *6 Fan speed for air volume Low input *63 External fan speed input setting ( - VDC) EA fan monitor output By-pass monitor output SA fan monitor output Operation monitor output for Pre-heater SA fan monitor with delay operation C - C - C -3 C -4 C -5 C -6 C -7 C hr hr 3 hr 4 hr 5 hr - Fan speed 4 Fan speed Fan speed 3 Fan speed Pattern X Pattern Y Pattern Z - Initialization - Initialize This table shows the summary of function settings. Please refer to the following pages for more details. The functions indicated with * are newly added or modified from LGH-RX5-E series. The functions indicated with in the DIP-SW No. column are available only when using with remote controller PZ-6DR-E Eng-4

15 Function settings (continued) No. Filter maintenance and fan power up setting against filter choking Set the schedule for filter cleaning based on the estimated concentration of dust in the air. When fan power up is available, exhaust and supply fans power up at, hrs and, hrs gradually. If function No. 55 or No. 56 is already worked, fan power up function may not available. Estimated hour differs by actual operated fan speed. DIP-SW PZ-6DR-E Filter maintenance Fan power SW No. Function No. Data indicator UP DIP-SW Indicate at estimated 3, hrs SW5-5 Indicate at ON 3 estimated 3, hrs Available When the setting for the cumulative operation time of the is exceeded, the filter cleaning icon will appear on the indoor unit remote controller or the remote controller. After cleaning the filter, the filter cleaning icon can be reset. Refer to the Instruction book for the remote controller. No. core maintenance indicator setting Set to enable core maintenance display. Estimated hour differs by actual operated fan speed. This function is from unit DIP-SW. DIP-SW PZ-6DR-E core SW No. Function No. Data maintenance indicator Indicate at estimated 6, hrs No.5 Automatic recovery setting after power interruption Sets for automatic recovery following power interruption. DIP-SW PZ-6DR-E Automatic recovery SW No. Function No. Data DIP-SW SW5-4 5 Stop when the power is on Start when the power is on ON 3 returns to the state before interruption No.7 Indoor positive pressure setting Supply fan speed becomes bigger than exhaust fan speed. Remote controller indicates fan speed of supply fan. DIP-SW PZ-6DR-E Down level of exhaust SW No. Function No. Data fan speed DIP-SW SW-5 7 Exhaust fan speed is ON down to supply fan speed Exhaust fan speed is 3 down to supply fan speed No.8 Max. fan speed setting during the first 3 minutes This sets the fan to run forcibly for 3 minutes when operation starts to ventilate the indoor area. After 3 minutes, fan speed can be changed. Use this setting if the indoor air is contaminated at night when the system is shut down and you desire to ventilate the indoor area quickly when operation is started in the morning. This function is from unit DIP-SW. During this function is working, is displayed at PZ-6DR-E and selected fan speed is displayed. DIP-SW PZ-6DR-E Max. fan speed setting SW No. Function No. Data during the first 3 minutes 8 Available No.9 Delay start setting for air conditioner starting Delays operation for 3 minutes when City Multi or Mr. Slim starts operating or when a external device starts operating. This function is available only when is interlocked with air conditioners. This function is during Night-purge. DIP-SW PZ-6DR-E SW No. Function No. Data SW5- Fan speed Display Supply fan delay start DIP-SW 9 5 min ON 3 3 min Exhaust fan down down English No. 6 Indoor negative pressure setting Exhaust fan speed becomes bigger than supply fan speed. Remote controller indicates fan speed of exhaust fan. Fan speed Display Exhaust fan Supply fan down down DIP-SW PZ-6DR-E Down level of supply fan SW No. Function No. Data speed DIP-SW SW-4 6 Supply fan speed is ON down to exhaust fan speed Supply fan speed is 3 down to exhaust fan speed No.3 Exhaust fan setting during air conditioner defrosting This function can be used under the condition supply duct is connected to Mr. Slim or City Multi indoor unit. Sets the operation of the exhaust fan during defrosting of the air conditioner (when supply fan stop). To enable this function, it is necessary to set the DIP-SW of the indoor unit also. Please refer to its manual. DIP-SW PZ-6DR-E SW No. Function No. Data SW5-3 Exhaust fan operation during air conditioner defrosting DIP-SW 3 Stop ON No change Eng-5

16 Function settings (continued) No.4 Exhaust fan setting at OA temperature lower than -5 C Sets the operation of the exhaust fan when the outdoor air is lower than -5 C (when supply fan stop). DIP-SW PZ-6DR-E SW No. Function No. Data SW5-3 SW ON Stop 5-3 ON No change 5-3 ON 5-9 ON Exhaust fan operation at outdoor temp. -5 C or less DIP-SW Forced to fan speed or less* * In case is operating fan speed, exhaust fan keeps fan speed. Function No. 3 and No. 4 are included in DIP-SW 5-3, then it is impossible to set independently without PZ-6DR-E. No.5 Interlock mode setting These settings indicate how should operate when external devices are started or stopped. DIP-SW PZ-6DR-E SW No. Function No. Data SW5-7 SW ON ON 5-7 ON 5-8 ON 5 No.8 Pulse input setting 3 4 Interlock setting DIP-SW The will start and stop according to the operation of the external devices. Subsequent operation will be possible using the remote controller for the or MELANS. The will start whenever external devices are operated. stop operation will be possible using its remote controller or MELANS. The will stop whenever external devices are stopped. start operation will be possible using its remote controller or MELANS. The will start and stop according to the operation of the external devices. Control via the remote controller or MELANS will only be possible when external devices are stopped. Set external input signal type from external device for TM. DIP-SW PZ-6DR-E SW No. Function No. Data SW- Pulse input setting DIP-SW 8 NOT pulse input ON Pulse input No.3 Night-purge setting ) Air volume Set fan speed during Night-purge. To use Night-purge function, it is necessary to set No. 3, No. 3, No. 3 correctly. This function is from unit DIP-SW. DIP-SW PZ-6DR-E SW No. Function No. Data No.3 Night-purge setting ) Air volume (Night-purge function is not available) Fan speed 3 Fan speed 3 Fan speed 3 4 Fan speed 4 Night-purge setting ) Outdoor and indoor temperature gap Set one of conditions for Night-purge start, temperature gap between indoor and outdoor. When the actual gap between indoor and outdoor becomes bigger than the setting, Night-purge starts. This function is from unit DIP-SW. DIP-SW PZ-6DR-E Indoor temperature - SW No. Function No. Data outdoor temperature C or more C or more C or more 3 3 C or more C or more 5 5 C or more 6 6 C or more 7 7 C or more Night-purge setting 3) No.3 The lowest outdoor temperature Set one of conditions for Night-purge start, maximum outdoor temperature within 4 hours. When this setting temperature is low, it is likely to start Night-purge. This function is from unit DIP-SW. DIP-SW PZ-6DR-E The maximum outdoor SW No. Function No. Data temp. within 4 hrs 5 C or more 6 C or more 7 C or more 3 8 C or more 4 9 C or more 5 C or more 6 C or more 3 7 C or more 8 3 C or more 9 4 C or more 5 C or more 6 C or more 7 C or more 3 8 C or more 4 9 C or more 5 3 C or more No.34 Input setting Set to follow input to the main unit from air conditioner, fan speed controller, etc. This function is from unit DIP-SW. Eng-6 DIP-SW PZ-6DR-E Input setting SW No. Function No. Data 34 Main unit input Individual input

17 Function settings (continued) No.36 Outdoor temperature display setting Set to display outdoor temperature detected by unit thermistor or not. This function is from unit DIP-SW. No.4 Outdoor temperature correction Set the correction for the outdoor temperature displayed on the PZ-6DR-E screen by function No. 36. This function is from unit DIP-SW. English DIP-SW PZ-6DR-E SW No. Function No. Data 36 Outdoor temperature display Display on the screen of PZ-6DR-E No.37 Indoor temperature display setting Set to display indoor temperature detected by unit thermistor or not. This function is from unit DIP-SW. DIP-SW PZ-6DR-E SW No. Function No. Data 37 No.38 Indoor temperature display Display on the screen of PZ-6DR-E Calculated supply air temperature display setting Set to display calculated supply air temperature or not. This function is from unit DIP-SW. DIP-SW PZ-6DR-E SW No. Function No. Data 38 No.39, 4 Calculated supply temperature display Display on the screen of PZ-6DR-E Temperature exchange efficiency setting Set the digit of temperature exchange efficiency which is used to calculate supply air temperature. This function is from unit DIP-SW. DIP-SW PZ-6DR-E digit of temperature SW No. Function No. Data exchange efficiency DIP-SW PZ-6DR-E digit of temperature SW No. Function No. Data exchange efficiency DIP-SW PZ-6DR-E The correction to SW No. Function No. Data thermistor detection -7 C -6 C -5 C 3-4 C 4-3 C 5 - C 6 - C 4 7 C 8 + C 9 + C +3 C +4 C +5 C 3 +6 C 4 +7 C No.4 Indoor temperature correction Set the correction for the indoor temperature displayed on the PZ-6DR-E screen by function No. 37. This function is from unit DIP-SW. DIP-SW PZ-6DR-E The correction to SW No. Function No. Data thermistor detection -7 C -6 C -5 C 3-4 C 4-3 C 5 - C 6 - C 4 7 C 8 + C 9 + C +3 C +4 C +5 C 3 +6 C 4 +7 C No.5 Automatic ventilation mode setting Set the pattern of conditions to go into By-pass mode in automatic ventilation operation. When setting Data is set 3 by PZ-6DR-E, function No. 5, No. 53, and No. 54 are available. DIP-SW PZ-6DR-E SW No. Function No. Data SW-7 Conditions to go into By-pass mode DIP-SW Pattern A Indoor temperature is 6 C or more Outdoor temperature is 6 C or more Indoor temperature - 5 outdoor temperature C ON Pattern B Indoor temperature is C or more Outdoor temperature is 8 C or more Indoor temperature - outdoor temperature C 3 Free setting * Pattern A is more likely to become By-pass mode than pattern B. Eng-7

18 Function settings (continued) Note; The ventilation mode follows the table below. Interlocked air conditioner Remote controller (Mr. Slim or City Multi) Energy recovery Energy recovery ventilation ventilation mode mode Either Yes or No By-pass ventilation By-pass ventilation mode mode Cooling/Stop Automatic (Follows the map) Automatic Always energy recovery Other than above ventilation mode No.5 Automatic ventilation mode setting ) Outdoor and indoor temperature gap Set one of conditions for By-pass mode in auto ventilation operation, temperature gap between indoor and outdoor. This function is from unit DIP-SW. This function is available when setting Data 3 is selected at function No. 5. DIP-SW PZ-6DR-E Indoor temperature - SW No. Function No. Data outdoor temperature C or more C or more C or more C or more 4 4 C or more 5 5 C or more 6 6 C or more 7 7 C or more No.53 Automatic ventilation mode setting ) The lowest outdoor temperature Set one of conditions for By-pass mode in auto ventilation operation, minimum outdoor temperature which comes in indoor directly. This function is from unit DIP-SW. This function is available when setting Data 3 is selected at function No. 5. DIP-SW PZ-6DR-E Outdoor temperature SW No. Function No. Data C or more C or more C or more 3 3 C or more 4 4 C or more 5 5 C or more 6 6 C or more C or more 8 8 C or more 9 9 C or more C or more C or more C or more 3 3 C or more 4 4 C or more 5 5 C or more No.54 Automatic ventilation mode setting 3) The lowest indoor temperature setting Set one of conditions for By-pass mode in auto ventilation operation, minimum indoor temperature. This function is from unit DIP-SW. This function is available when setting Data 3 is selected at function No. 5. When is interlocked to Mr. Slim or City Multi indoor unit, the target temperature of the indoor unit is the lowest indoor temperature for By-pass mode DIP-SW PZ-6DR-E Indoor temperature SW No. Function No. Data 5 C or more 6 C or more 7 C or more 3 8 C or more 4 9 C or more 5 C or more 6 C or more 54 7 C or more 8 3 C or more 9 4 C or more 5 C or more 6 C or more 7 C or more 3 8 C or more 4 9 C or more 5 3 C or more Free By-pass setting User can set conditions to go into By-pass mode in automatic ventilation mode by function No. 5, No. 53 and No. 54. examples are shown below. Example * By-pass/Energy recovery ventilation map in automatic ventilation mode Outdoor temperature ( C) Set by function No. 54 (Terget temp. of air conditioner) Energy recovery ventilation area Set by function No. 5 By-pass ventilation area Set by function No Indoor temperature ( C) Function No. Data 5 ( C) 53 ( C) 54 (7 C) Eng-8

Two remote controller system with one Lossnay Basic System (Refer to page C-10) Multiple Lossnay units with one remote controller.

Two remote controller system with one Lossnay Basic System (Refer to page C-10) Multiple Lossnay units with one remote controller. Control CHAPTER 1 System Design 1. System Examples One with one remote Multiple units with one remote Two remote system with one Basic System (Refer to page C-10) Non-polar Two wires Power supply Remote

More information

Lossnay Remote Controller

Lossnay Remote Controller Remote Controller . Summary Technical manual detailing the control and operation of commercial-type units (LGH-RX5-E Series). Possible System Configurations () When using only the remote. (2) Linking

More information

TECHNICAL MANUAL (CONTROLS) Models. Lossnay Unit. Lossnay Remote Controller LGH-150RX3-E LGH-25RX3-E LGH-35RX3-E LGH-50RX3-E LGH-80RX3-E LGH-100RX3-E

TECHNICAL MANUAL (CONTROLS) Models. Lossnay Unit. Lossnay Remote Controller LGH-150RX3-E LGH-25RX3-E LGH-35RX3-E LGH-50RX3-E LGH-80RX3-E LGH-100RX3-E TECHNICAL MANUAL (CONTROLS) Models Unit LGH-15RX3-E LGH-25RX3-E LGH-35RX3-E LGH-50RX3-E LGH-80RX3-E LGH-100RX3-E LGH-150RX3-E LGH-200RX3-E Remote Controller PZ-41SLB-E PZ-52SF-E CONTENTS 1. Summary...............................................................................

More information

Mitsubishi Electric Air-conditioner Network System

Mitsubishi Electric Air-conditioner Network System Mitsubishi Electric Air-conditioner Network System Central Controller Model: GB-50A Installation Manual Contents 1. Safety Precautions to be Observed without Fail...1 2. Confirmation of Parts...3 3. Product

More information

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL

Installation Manual INTELLIGENT SERVER. Model name: BMS-LSV6UL Model name: BMS-LSV6UL INTELLIGENT SERVER Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER. Please read this manual carefully beforehand for proper installation of the SERVER. NOTE This

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

Power supply unit Model: PAC-SC51KUA

Power supply unit Model: PAC-SC51KUA Air-Conditioner Control System Power supply Model: PAC-SC51KUA Installation Manual Contents 1. Safety Precautions...1 2. Product features...2 1. Specifications...2 2. Power supply capacity...2 3. External

More information

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004

TOP - 1. Instruction Manual. Version 1.0 Produced in Jan. 2004 Version 1.0 Produced in Jan. 2004 Instruction Manual LCD monitor IV-08MP Thank you for purchasing the SHARP IV-08MP LCD monitor. Read this introductory instruction manual carefully to thoroughly familiarize

More information

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION

H Series PLC. ! : Indicates Compulsion. EH-150 Analog input module EH-AXH8M Instruction manual. Safety precautions DANGER CAUTION COMPULSION H Series PLC EH-150 Analog input module EH-AXH8M Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction manual and all the

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS Wired Remote Controller 7 Day Programmable Ductless Systems KSACN0401AAA (High Wall Models) KSACN0501AAA (Ducted/Cassette Models) INSTALLATION INSTRUCTIONS NOTE: Read the entire instruction manual before

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

Central Controller Model: G-50A

Central Controller Model: G-50A G-50A Mitsubishi Electric Air-conditioner Network System Central Controller Model: G-50A Installation Manual Contents / CENTRAL CTROLLER 1. Safety precautions to be observed without fail... 1 2. Confirmation

More information

PAR-WT50R-E PAR-WR51R-E

PAR-WT50R-E PAR-WR51R-E Wireless Remote Controller and Receiver PAR-WT50R-E PAR-WR51R-E This manual explains installation of the PAR-WR51R-E wireless receiver and the PAR-WT50R-E wireless remote controller, and settings of these

More information

Haze 800 DMX. User Guide. English

Haze 800 DMX. User Guide. English Haze 800 DMX User Guide English Introduction Box Contents Haze 800 DMX Remote Control (wired) User Guide Safety & Warranty Manual Support For the latest information about this product (documentation, technical

More information

Conductive Level Controller

Conductive Level Controller Conductive Level Controller 61F-D21T-V1 Ideal for level control for industrial facilities and equipment. Outputs can be set to self-hold at ON or OFF using self-holding circuits. Sensitivity adjustment

More information

Motorized Curtain Tracks Progress 50 Motor Set

Motorized Curtain Tracks Progress 50 Motor Set Troubleshooting Before you decide that the trouble is a malfunction, perform the following check. Condition Not operating Unstable operation Moves adversely and in opposite direction Operation speed is

More information

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm

Thread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information

More information

INSTALLATION MANUAL For authorized service personnel only.

INSTALLATION MANUAL For authorized service personnel only. AIR CONDITIONER SIMPLE REMOTE CONTROLLER (WIRED TYPE) UTY-RSNUM INSTALLATION MANUAL For authorized service personnel only. English Français Español Contents. SAFETY PRECAUTIONS...2 2. ACCESSORIES...2 3.

More information

TOUCH SCREEN CONTROLLER for Air Conditioning Control System

TOUCH SCREEN CONTROLLER for Air Conditioning Control System INSTALLATION MANUAL TOUCH SCREEN CONTROLLER for Air Conditioning Control System Model: BMS-TP064ACE BMS-TP064PWE BMS-TP52ACE BMS-TP52PWE Thank you very much for purchasing the TOSHIBA Touch Screen Controller.

More information

Wireless LAN Connecting Adapter [BRP072B42] Installation Manual

Wireless LAN Connecting Adapter [BRP072B42] Installation Manual Wireless LAN Connecting Adapter [BRP072B42] Installation Manual Wireless LAN Connecting Adapter [BRP072B42] Installation Manual Website: http://www.daikinthai.com/wlan3/modbus For details on specifications,

More information

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E

DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

InView Marquee Message Display

InView Marquee Message Display Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.

More information

Cable specifications PVC

Cable specifications PVC IO-Link Proximity Sensor (Spatter-resistant Models) EEQ-@-IL@ IO-Link Makes Sensor Level Information Visible and Solves the hree Major Issues at Manufacturing Sites! A Proximity Sensor hat Can Be Used

More information

Touch-controller_IM_03943A_1_Co_EN.indd 오후 3:06:00

Touch-controller_IM_03943A_1_Co_EN.indd 오후 3:06:00 Touch-controller_IM_03943A_1_Co_EN.indd 2 2013-06-28 오후 3:06:00 Touch Centralized Controller MCM-A300N Air Conditioner installation manual This manual is made with 100% recycled paper. imagine the possibilities

More information

PV Module Installation Instructions

PV Module Installation Instructions Name 1601A Page 1 / 8 Name 1601A Page 2 / 8 1 Introduction Thanks for purchasing PV modules of HT SOLAR ENERGY JOINT STOCK COMPANY This manual refers to PV modules manufactured and sold by HT Turkey. This

More information

INTELLIGENT SERVER. Model: BMS-LSV6E

INTELLIGENT SERVER. Model: BMS-LSV6E INSTALLATION MANUAL INTELLIGENT SERVER Model: BMS-LSV6E Thank you very much for purchasing this TOSHIBA INTELLIGENT SERVER. Please read this manual carefully beforehand for proper installation of the SERVER.

More information

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL

CM E FUJITSU SEMICONDUCTOR CONTROLLER MANUAL F 2 MC-16L/16LX EMULATION POD MB HARDWARE MANUAL FUJITSU SEMICONDUCTOR CONTROLLER MANUAL CM42-00411-2E F 2 MC-16L/16LX EMULATION POD MB2145-507 HARDWARE MANUAL F 2 MC-16L/16LX EMULATION POD MB2145-507 HARDWARE MANUAL FUJITSU LIMITED PREFACE Using the

More information

Wireless Remote Controller Kit

Wireless Remote Controller Kit INSTALLATION MANUAL Wireless Remote Controller Kit LS BRC4C8 Read these instructions carefully before installation. Keep this manual in a handy place for future reference. This manual should be left with

More information

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10)

PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10) TEC (Peltier) Controller PLC-24V10AL(-PT/-TH) Quick Start Manual (Rev.1.10) Thank you for purchasing the TEC (Peltier) Controller PLC-24V10AL. Read these operating instructions carefully to ensure effective

More information

Optional add-on cassette Attachment Instruction manual

Optional add-on cassette Attachment Instruction manual E6580774 Optional add-on cassette Attachment Instruction manual 1. INTRODUCTION 3 2. CONNECTION TO THE INVERTER 4 2.1 Fixing the option alone 4 2.2 Connection to the inverter 6 3. SPECIFICATION 8 4. WARRANTY

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

NIR Moisture Analyzer KB-30

NIR Moisture Analyzer KB-30 NIR Moisture Analyzer KB-30 Operation Manual Safety Precautions FPL950701 Improper use of the NIR moisture analyzer in violation of the following safety notes may result in death, injury or damage to property

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS... Thank you for your purchase of this product. Before operating the product, please read this instruction manual carefully to ensure proper use of the product. Please store this instruction manual in a safe

More information

E2Q4 Square Proximity Sensor

E2Q4 Square Proximity Sensor Inductive Square Slim, compact size M2 Plug-in connection Integrated short circuit and reverse polarity protection Active face positioning: Y-axis 5, X-axis 90 incremets Ordering Information DC type Connection

More information

Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter

Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter 2 Instruction Manual (Supplementary) Totally-Enclosed Box Type Inverter TOSVERT VF-S11 Thank you for purchasing a Toshiba Totally-enclosed box type TOSVERT VF-S11 series inverter. This Manual gives a supplementary

More information

Thread length (overall length)

Thread length (overall length) Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd.

Operation Manual WARNING. Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. WARNING Be sure to read this Operation Manual before use. Universal Space Amusement Equipment Ltd. CONTENTS 1. The company..2 2. Specifications.. 3 3. Package Contents..5 4. Installation, Fix and Transport..6

More information

INSTALLATION MANUAL. Gateway option box EKLONPG EKBNPG

INSTALLATION MANUAL. Gateway option box EKLONPG EKBNPG INSTALLATI MANUAL CTENTS Page FUNCTI Accessories... Function... Name and function of parts... Selecting the installation site... Mechanical installation... Electric wiring work... Precautions... Connecting

More information

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System

Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System USER MANUAL Line Interactive 1000VA/1400VA/2000VA Uninterruptible Power System 614-06762-00 IMPORTANT SAFETY INSTRUCTIONS SAVE THESE INSTRUCTIONS This manual contains important instructions for Line Interactive

More information

4P M. Wireless LAN Connecting Adapter <BRP069A45> Installation Manual

4P M. Wireless LAN Connecting Adapter <BRP069A45> Installation Manual 4P359542-3M Wireless LAN Connecting Adapter Installation Manual Wireless LAN Connecting Adapter Installation Manual Homepage: http://www.onlinecontroller.daikineurope.com For details

More information

Cylindrical Proximity Sensor

Cylindrical Proximity Sensor Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition

More information

1:1 Model Connection Interface

1:1 Model Connection Interface Air Conditioner Installation Manual 1:1 Model Connection Interface Model name: TCB-PCNT31TLUL Installation Manual Digital Inverter Air Conditioner 1 English Manuel d installation Climatiseur inverseur

More information

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY

JANOME DESKTOP ROBOT JR2000N Series. Operation Manual. <Setup> For Qualified Installer ONLY JANOME DESKTOP ROBOT JR2000N Series Operation Manual For Qualified Installer ONLY Thank you for purchasing the Janome Robot. *Read this manual thoroughly in order to properly use this robot. Be sure

More information

Chameleon Stand-alone

Chameleon Stand-alone Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools

More information

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS...

CONTENTS PRODUCT FEATURES... EG-2 SAFETY PRECAUTIONS... EG-2 PARTS DESCRIPTION... EG-3 INSTALLATION AND ADJUSTMENT... EG-4 SPECIFICATIONS... Thank you for your purchase of this product. Before operating the product, please read this instruction manual carefully to ensure proper use of the product. Please store this instruction manual in a safe

More information

4P Wireless LAN Connecting Adapter <BRP069B41> <BRP069B42> <BRP069B43> <BRP069B44> <BRP069B45> Installation Manual

4P Wireless LAN Connecting Adapter <BRP069B41> <BRP069B42> <BRP069B43> <BRP069B44> <BRP069B45> Installation Manual 4P481234-1 Wireless LAN Connecting Adapter Installation Manual Wireless LAN Connecting Adapter Installation Manual Homepage: http://www.onlinecontroller.daikineurope.com

More information

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS

IO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS Procon IO-INTERFACE FOR INSTALLERS INSTALLATION MANUAL Version 1.01 For safe and correct use, please read this installation manual thoroughly before installing the PROCON IO-INTERFACE. MITSUBISHI ELECTRIC

More information

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit

Operation Manual. Fieldbus system EX510-GDN1. DeviceNet Compatible GW unit Fieldbus system DeviceNet Compatible GW unit Operation Manual EX50-GDN URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8-507-89 Fax: +8-598-56 Note: Specifications

More information

Installation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C*

Installation Manual. 1.Included Accessories. System Controller SC-201-6M INT. Requests to Installers *SHA8754 C* System Controller SC-201-6M INT Installation Manual Potential dangers from accidents during installation and use are divided into the following two categories. Closely observe these warnings, they are

More information

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English.

Owner s Manual RBC-AX32U(W)-E RBC-AX32U(WS)-E AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit. Model name: English. AIR CDITIER (SPLIT TYPE) Owner s Manual Wireless remote controller kit Model name: RBC-AX3U(W)-E RBC-AX3U(WS)-E Generic model name RBC-AX3U(W)-E Wireless remote controller model name WH-LSE Signal receiving

More information

DESIGN & TECHNICAL MANUAL

DESIGN & TECHNICAL MANUAL AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARYG72LHTA ARYG90LHTA OUTDOOR AOYG72LRLA AOYG90LRLA DR_AR012EF_03 2017.04.07 Notices: Product specifications and design are subject to change

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS Adaptor Model No. CZ-CFUNC1U For your safety Read the following instructions carefully, and carry out secure installation and electrical work. The precautions given in this manual

More information

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit

Operation Manual. Fieldbus system EX510-GPR1. PROFIBUS DP Compatible GW unit Fieldbus system PROFIBUS DP Compatible GW unit Operation Manual EX50-GPR URL http://www.smcworld.com Akihabara UDX 5F, --, Sotokanda, Chiyoda-ku, Tokyo 0-00, JAPAN Phone: +8 3-507-89 Fax: +8 3-598-536

More information

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual

OPC-VG1-PG / PGo. PG Interface Card for FRENIC-VG. Instruction Manual Instruction Manual PG Interface Card for FRENIC-VG OPC-VG1-PG / PGo Thank you for purchasing our PG interface card designed for the high-performance, vector control FRENIC-VG series of inverters. - Improper

More information

Enphase S-Series Microinverter and Engage Cable Safety

Enphase S-Series Microinverter and Engage Cable Safety SAFETY Enphase S-Series Microinverter and Engage Cable Safety Important Safety Information (S280-60-LL and S230-60-LL) This document contains important instructions to use during installation of the Enphase

More information

ICS Entrance Management Sign Installation Guide. Version 1.0

ICS Entrance Management Sign Installation Guide. Version 1.0 ICS Entrance Management Sign Installation Guide Version 1.0 Thank you for purchasing your new ICS Entrance Management System (EMS) from Innovative Control Systems, Inc. Installation Overview This document

More information

Aluminum-detecting Proximity Sensor (Separate Amplifier Type)

Aluminum-detecting Proximity Sensor (Separate Amplifier Type) Aluminum-detecting Proximity Sensor (Separate Amplifier Type) ECY Simple Teaching Function for Simple Adjustment. Easy-to-see Excess Gain Level Indicators. Detects aluminum, copper, and other non-ferrous

More information

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4.

E2K-F. Flat Capacitive Sensor with a Thickness of Only 10 mm. Flat Proximity Sensor. Ordering Information. Sensors [Refer to Dimensions on page 4. Flat Proximity Sensor EK-F CSM_EK-F_DS_E Flat Capacitive Sensor with a Thickness of Only mm Flat Sensor with excellent space efficiency. (Model with built-in Amplifier is only mm thick.) Direct mounting

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information

S8VE (60/90/120/180/240-W Models)

S8VE (60/90/120/180/240-W Models) Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,

More information

Users Manual STP-103II. Thermal Printer Rev

Users Manual STP-103II. Thermal Printer Rev Users Manual STP-103II Thermal Printer Rev. 1.00 http://www.bixolon.com Safety Precautions The instructions shown below must be followed to prevent possible danger or damage by using the product incorrectly.

More information

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR Built-in Power Supply Photoelectric Sensor CSM DS_E_12_3 Model Contribute to Overall Cost Reduction erminal Block Models Easy to wire and adjust. For the most recent information on models that have been

More information

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL

Slim Ducted type. Contents MMD-AP 4SPH2UL MMD-AP0094SPH2UL MMD-AP0124SPH2UL MMD-AP0154SPH2UL MMD-AP0184SPH2UL E5-3I D-AP 4SP2U Slim Ducted type D-AP0074SP2U D-AP0094SP2U D-AP024SP2U D-AP054SP2U D-AP084SP2U Contents. Specifications 2. Dimensions 3. Center of gravity 4. Piping diagram 5. Wiring diagram 6. Electrical

More information

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation

More information

M215 (M215-60) Safety

M215 (M215-60) Safety M215 QUICK INSTALL GUIDE M215 (M215-60) Safety Important Safety Information This document contains important instructions to use during installation and maintenance of the Enphase M215 Microinverter. To

More information

Analog Monitor Installation Manual

Analog Monitor Installation Manual Analog Monitor Installation Manual Part Number: 144-23919 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems and equipment.

More information

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety

EE-SPX74/84. Ordering Information. Compact Sensor for High-Density Mounting with Easy Snap-In Connector. H Connector features a built-in safety Compact for High-Density Mounting with Easy Snap-In Connector H Connector features a built-in safety lock for shock and vibration resistance H replacement made simple without rewiring H Cables can be bent

More information

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual Document 481200 VGD-100 Vari-Green Drive Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

OPERATING INSTRUCTION

OPERATING INSTRUCTION OPERATING INSTRUCTION AUTORANGING MULTIMETER MAX Ω F C 10A MAX every 15 min. COM V SAFETY INFORMATION The following safety information must be observed to insure maximum personal safety during the operation

More information

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm

Shape Model Measurement range Model Straight 50 to 300 mm. Straight 70 to 800 mm Digital Amplifier Ultrasonic Sensor CSM DS_E_1_1 A Reflective Sensor That Handles All Types of Sensing Object Colors and Patterns Compact with a Broad Selection of Side-view Heads Slim with analog outputs

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TS1000C TS700C INSTALLATION INSTRUCTIONS CONTENT: 1. Important safety instructions. 2. Specifications and main dimensions. 3. Parts included. 4. Installation. 5. RF remote system. 6. Feature functions

More information

B&W RearView Camera Installation & Operation

B&W RearView Camera Installation & Operation B&W RearView Camera Installation & Operation CA52 (Camera) FOR MORE INFORMATION WWW.STRATEGICVISTA.COM BEFORE OPERATING THIS SYSTEM, PLEASE READ THIS MANUAL THOROUGHLY AND RETAIN IT FOR FUTURE REFERENCE

More information

1 Channel Strobe Controller ORDERCODE 40226

1 Channel Strobe Controller ORDERCODE 40226 1 Channel Strobe Controller ORDERCODE 40226 Congratulations! You have bought a great, innovative product from Showtec. The Showtec Strobe Controller brings excitement to any venue. Whether you want simple

More information

Analog Input Installation Manual

Analog Input Installation Manual Analog Input Installation Manual August 2011 Part Number: 144-23917 Copyright 2011 Magnetek 1. Preface and Safety Magnetek manufactures products used as components in a wide variety of industrial systems

More information

User's Guide. MiniTec TM Series Model MN25 MultiMeter

User's Guide. MiniTec TM Series Model MN25 MultiMeter User's Guide MiniTec TM Series Model MN25 MultiMeter Warranty EXTECH INSTRUMENTS CORPORATION warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a

More information

4P S. Wireless LAN Connecting Adapter <BRP069A41> Installation Manual

4P S. Wireless LAN Connecting Adapter <BRP069A41> Installation Manual 4P359542-1S Wireless LAN Connecting Adapter Installation Manual Wireless LAN Connecting Adapter Installation Manual Homepage: http://www.onlinecontroller.daikineurope.com For details

More information

4P R. Wireless LAN Connecting Adapter <BRP069A81> Installation Manual

4P R. Wireless LAN Connecting Adapter <BRP069A81> Installation Manual 4P359542-4R Wireless LAN Connecting Adapter Installation Manual Wireless LAN Connecting Adapter Installation Manual Homepage: http://www.onlinecontroller.daikineurope.com For details

More information

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL

MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL MOBILE CONNECTOR - GEN 2 OWNER'S MANUAL UNITED STATES Contents Safety Information... 2 Save These Important Safety Instructions... 2 Warnings...2 Cautions...3 General Information... 4 Mobile Connector

More information

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS

COMFORT CONTROL CENTER SERVICE INSTRUCTIONS USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center

More information

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual

LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic

More information

QUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12

QUICK START GUIDE. vau4/3. Frequency converter.   operating instructions /12 operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A CSM_ES-A_DS_E Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection

More information

BGS (at min. setting) BGS (at max. setting)

BGS (at min. setting) BGS (at max. setting) Compact Photoelectric Sensor with Built-in Amplifier EZ-LS CSM_EZ-LS_DS_E_7_ Distance-settable Sensor Unaffected by Workpiece Color and Background Distance-settable triangulation model unaffected by color.

More information

Air Conditioning Control System Remote Monitoring Interface CMS-RMD-J Installation and Instructions Manual

Air Conditioning Control System Remote Monitoring Interface CMS-RMD-J Installation and Instructions Manual Air Conditioning Control System Remote Monitoring Interface CMS-RMD-J Installation and Instructions Manual Safety notes are marked with WARNING or CAUTION, depending on the severity of possible consequences

More information

M250 (M LL) Safety

M250 (M LL) Safety M250 SAFETY M250 (M250-60-2LL) Safety Important Safety Information This document contains important instructions to use during installation of the Enphase M250 Microinverter. To reduce the risk of electrical

More information

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs

IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,

More information

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide.

The following symbols are used to show dangerous operation or handling. Make sure you understand them before reading the guide. Safety Instructions Before use Thank you very much for purchasing this product. This product is an interface box called "Connection & Control Box" for EPSON short throw projectors. For your safety, read

More information

Suitable for detecting transparent films or transparent bottles

Suitable for detecting transparent films or transparent bottles Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16

More information

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443 Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443 IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY. PARTS LIST: 2 Metal Plate Stands 5 Greenery

More information

FT-20 Fire Training Fog Machine User Manual English

FT-20 Fire Training Fog Machine User Manual English FT-20 Fire Training Fog Machine User Manual English 2018 Antari Lighting and Effects Ltd. 1 User Manual - English Safety Information Please read the following safety information carefully before operating

More information

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m) All voltage photoelectric sensors Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only x x 7.4 mm. s with long life expectancy and high switching capacity

More information

4P S. Wireless LAN Connecting Adapter <BRP069A42> Installation Manual

4P S. Wireless LAN Connecting Adapter <BRP069A42> Installation Manual 4P359542-2S Wireless LAN Connecting Adapter Installation Manual Wireless LAN Connecting Adapter Installation Manual Homepage: http://www.onlinecontroller.daikineurope.com For details

More information

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1

IO-PT4. Component identification. User safety and equipment protection guidelines. Unitronics Industrial Automation Systems 1 IO-PT4 I/O Expansion Module 4 PT100 Inputs (-50 to 460 C) The IO-PT4 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 4 PT100 inputs

More information

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1

Common to all H3CR. Basic Setting. Setting of Selectors. Selection of Operating Mode. Selection of Time Unit and Time Range. Common to all H3CR 1 Common to all H3CR Note: The undermentioned is common for all H3CR models. Basic Setting Setting of Selectors The s can be turned clockwise and counterclockwise to select the desired time unit, time range,

More information

Autoranging True RMS Multimeter User Manual

Autoranging True RMS Multimeter User Manual Autoranging True RMS Multimeter User Manual Please read this manual before switching the unit on. Important safety information inside. Contents Page 1. Safety Information... 4 2. Safety Symbols... 5 3.

More information

Model No. ET-JPF200BE

Model No. ET-JPF200BE Operating Instructions Floor Stand Kit Commercial Use Model No. ET-JPF200BE ET-JPF200WE ENGLISH FRANÇAIS ESPAÑOL DEUTSCH ITALIANO * The above illustration is of this product mounted to an optional projector.

More information

User Guide True RMS Multimeter Extech EX205T

User Guide True RMS Multimeter Extech EX205T User Guide Extech EX205T True RMS Digital Multimeter Extech EX210T True RMS Digital Multimeter IR True RMS Multimeter Extech EX205T Introduction Thank you for selecting the Extech EX205T True RMS Auto-ranging

More information