1 BIO-PRO Standalone / Weigand fingerprint reader Tel
2 v 4 x Master Card x0 User Card IP5 DEEE -0 C to +50 C The BIOSYS product complies with Directive 999/5/CE REMINDERS & RECOMMENDATIS Wiring Reminder The maximum distance between the controller and the reader head is 50m. Beware of mains (40Vac) connections. Recommended cables> 3 twisted pairs (EIA-485 standard), 3P SYT 4 AWG. Make sure the drain wire PE is connected. Surround Indicator LED s LED Colour MODE Environment The door controller must be installed internally. The reader head must be installed in a sheltered location from the weather. Operating temperature range of -0 C to + 50 C. Installation Recommendation To limit back EMF spikes, the varistor must be installed across the supply terminals of the lock. Recommended power supplies ( VDC) Power supplies must be Vdc with a minimum current provision of A. Please ensure you have taken into account the power requirements of the lock. Power must be a limited power source, compliant with EN BLUE WHITE RED GREEN ORANGE RED (flashing) Standby Finger detected Access denied Access granted Waiting for command Programming error Tel
3 MOUNTING mm.38 po mm.38 po ø Tel
4 WIRING Make sure the drain wire PE is connected PE Pa Pa Pa3 M B A 4 Tel
5 IP5 < 50 m / 64 ft SYT 3P 4AWG IP5 VDC VDC (-0% / +0%) IN V Pa OUT V V NO C NC Alarm RL V NO C NC Door RL Pa3 Pa Bus Make sure the drain wire PE is connected PE 5 Tel
6 3PARAMETERS Reset mastercard System default LOCK RELAY TIME V WIEGAND bits 30 bits sec. 5 sec. 0 sec. WIEGAND V G H Common Ground Clock D0 Data 0 44 bits 5 sec. D Data DIP switch NOT USED 6 Tel
7 J J J3 J4 J5 P INSTALLATI WITH E READER HEAD J Buzzer J P J3 NOT USED J4 Permanently lit J5 Tamper alarm INSTALLATI WITH TWO READER HEADS PE PE - + M - + M Make sure the drain wire PE is connected B B J P A A J P 7 Tel
8 4 FIRST TIME POWER UP START BIOSYS Master Card 0 secs //3 Return to section, & 3 REGISTRATI OF FINGERPRINTS UP TO 500 USERS Note: If registration is not completed within 60 seconds, the unit will revert to standby Master Card User Card X6 Place your finger on the When the registration of sensor unit the user is completed, s, remove and place the unit will change to again - do this 6 times in white. At this point the total. fingerprint can be verified until the - then the unit changes to blue standby. Unknown Master Card 8 User Card already assigned If the fingerprint is not verified, the unit will change to blue standby after 0 seconds. Tel
9 5 NORMAL USE S If Permanently Lit is selected, then the LED surround will indicate all the time. If Permanently Lit is not selected, then the LED surround will be off, and will only indicate when it senses a finger present - with no activity, the LED surround will Unrecognised fingerprint remain lit for 30 seconds then switch off. Preference of surround LED s is selected by J4 (see page 7). 6 MORE PROGRAMMING REMOVING A FINGERPRINT 5S / 8S max. User Card Unknown User Card Tel
10 6 MORE PROGRAMMING DUPLICATE THE MASTER CARD X3 B A New Master Card Existing Master Card A 3 = B MASTER CARD CANCELLATI DIP switch S Note: After deleting a Master Card, the next Master Card presented will automatically be added - as indicated by the green LED 4 RESET DIP switch 30S Note: Leave DIP on until the FIRST red LED flash with an audible chirp - turn DIP off. A further 3 red flashes will occur, followed by blue then flashing orange - a new Master Card can now be added Return to Section 4. Tel
11 A General Alarm will be activated: If the door contact (CP) is connected and there has been an attempt to force the door; or the door was not closed within 60 seconds of a valid transaction. If there is loss of communication between the controller and the reader head for more than 5 seconds. If there is an attempt to remove the reader head (tamper detection). While in programming mode, inaction will revert the reader head to sleep mode. Important note: The user cards are unique, and used for the registration and deletion of users. It is important to note which user card is registered to which user, and all cards should be kept in a safe and secure place. To Buy Additional Cards Please Visit: User name User Card No. User name User Card No. Tel
CM-500 SK 500 USER CODES KEYPAD
CM-500 SK 500 USER CODES KEYPAD Wiring diagram PCB front view ST2 1 3 1 3 N/C contact RL1 (magnet) N/O contact RL1 (strike) ST1 3 2 1 ST2 1 3 RL2 RL1 Strike 2 1 E M B 3 5 T C O 12 V V1 PB2 PB1 Input voltage
More informationFingerprint Identification Proximity Reader. Quick Installation Guide
Fingerprint Identification Proximity Reader Quick Installation Guide 1. WHAT S INCLUDED Please unpack and check the contents of the box. If any of these parts are missing, please contact a nearby distributor
More informationEN FULL DETAILS SKB. Vandal Resistant keypad - Full Details
EN FULL DETAILS SKB Vandal Resistant keypad - Full Details WARNINGS Carry out the installation by carefully following the instructions provided by the manufacturer in accordance with the current standards.
More informationPartizan PAB-FC2. Fingerprint scan time Fingerprint identification time. <0.5 s < % <0.0198% Ingress protection rating
1. Features & Technical Parameters 1.1 Features: Partizan PAB-FC2 Metal vandalproof housing Secure and reliable biometric fingerprint recognition Simple for using, wiring can be done by a user without
More informationUser Manual. PCKeypad Wireless Keypad
User Manual PCKeypad Wireless Keypad Description The PCKeypad is a wireless keypad with a PentaCODE transmitter built-in. It works with all of Elsema s PCR series receivers. The installer has the option
More informationF6-Fingerprint. Access Control/Reader. User Manual. F6 - Simplified Instruction. (Master Code) # (Factory default:1234) Enter the Programming Mode
-Fingerprint Access Control/Reader Function Description Enter the Programming Mode - Simplified Instruction Operation (Factory default:1234) Change the Master Code Add Fingerprint User Add Card User Add
More informationREX F-0-9 Standalone or Access Controller
REX F-0-9 Standalone or Access Controller Power supply The controller need s external power supply to operate. The Spider W40 power supply is sufficient to power two controllers and two 12V electric strikes
More informationEL-ST100 KEYPAD CONTROLLER
WIRING DIAGRAM EL-ST100 KEYPAD CONTROLLER WEATHER-PROOF STANDALONE ACCESS CONTROLLER WITH KEYPAD & PROXIMITY TECHNOLOGY Programming and Installation Manual NOTE: www.elock2u.com ICT at work! Version 3.6
More informationDG-800 Stand-Alone Proximity Reader Instruction Manual
DG-800 Stand-Alone Proximity Reader Instruction Manual I. Features 1. Memory volume up to 1000+10 proximity cards/tokens and PINs with the programming time up to 0.5 seconds. 2. Access modes: a. Only Proximity
More informationInstallation Instructions. i-net Access Control Units. Part Code: IA-PCB IA-ACB IA-ACU IA-KIT
Installation Instructions i-net Access Control Units Part Code: IA-PCB IA-ACB IA-ACU IA-KIT This device is configured for DHCP. Identity Access software will find this device, go to setup and controller,
More informationRFID/Digital Access Control Keypad
R Luminous/ RFID/Digital Access Control Keypad Model:YK-368L-R Germany EMC tested FEATURES AND FUNCTIONS Simple Programming, Easy Operation 3-Operation Mode: ID Card Operation, User Code Operation, ID
More informationKP2000E/EM Series Style Keypad
23852973 KP2000E/EM Series Style Keypad Installation and Programming Instructions Models KP2000EXX and KP2000EMXX Specifications Parameter Voltage Requirements Keypad Current Requirements (Max) Relay Contact
More informationBIOC3 V1 USER S MANUAL. Biometric Reader v. b1
BIOC3 V1 EN Biometric Reader USER S MANUAL v. b1 www.xprgroup.com 1 Contents 1. DESCRIPTION 2. SPECIFICATIONS 3. MOUNTING 4. WIRING 5. CONNECTING BIOMETRIC READERS TO EWS CONTROLLER 5.1 CONNECTING BIOMETRIC
More information6222 Two Door Module Technical Operations Manual
6222 Two Door Module Technical Operations Manual TABLE OF CONTENTS Specifications...3 Overview...4 Operations...5 Custom Access Mode...5 Standard Access Mode...5 Offline Access Mode...5 Offline Memory...5
More informationSafety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate
www.zkaccess.com Safety Precautions How to place the finger Product Contents Product PIN Diagram Product Dimensions Cables and Connectors Installation of Back Plate Power Connection Ethernet Connection
More informationRD-SR2 ACCESS SECURITY PRODUCTS LTD. Proximity Card Reader with Remote Control. User Manual
RD-SR2 Proximity Card Reader with Remote Control User Manual INTRODUCTION The RD-SR2 is a compact, weather resistant multi-function card reader that can be used as a standalone programmable access control
More informationTwo Door Controller GEN-045
Australian Owned, Designed and Manufactured Two Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au Distributed by: Genesis reserves the right to change or modify
More informationCM-110SK Standalone Keypad Installation Instructions
CM-0SK Standalone Keypad Installation Instructions. Packing List Qty Name Remarks 2 2 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4 Φ(20 mm 60 mm) 0.24 x.2 Φ (6 mm
More informationSuprex RS-485 SPX-7500 Wired Reader-Extender
Suprex RS-485 SPX-7500 Wired Reader-Extender Product Manual SPX-7500_MAN_181206 Cypress Integration Solutions 35 Years of Access Control Ingenuity CypressIntegration.com 2018 Cypress Computer Systems 1778
More informationQuick Start Installation Guide
RM-DCM-2 Quick Start Installation Guide Version G0 Document Part Number UM-215 May 2010 OVERVIEW The RM-DCM-2 is a UL294 Listed and UL1076 Listed door control module that includes the RM-4E Reader Module
More informationB100-SA Standalone Biometric Reader
EN B100-SA Standalone Biometric Reader User Manual v.b1 Contents 1.0 INTRODUCTION 2.0 MOUNTING 3.0 SPECIFICATIONS......... 3 3 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING... 4 6.0 RECOMMENDED SWIPING TECHNIQUE...
More informationConnecting a Cisco Reader Module
CHAPTER 3 Overview The optional Cisco Reader Module (Figure 3-1) is similar to the Cisco Physical Access Gateway, providing the same ports for Weigand readers and other input and output devices. The Cisco
More informationMR51e Reader Interface
J4 J TB6 TB5 TB4 TB3 VIN VO TB2 TB J7 2.75 [69.85] 0.2 [5.08] 2.35 [59.69] J3 MR5e Reader Interface Installation and Specifications. General: www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA
More informationFingerprint Access Control F1. User Manual
Fingerprint Access Control F1 User Manual 1. Introduction F1 is a metal shell standalone fingerprint access control, using the America Atmel s MCU, with precise electron circuit and good productive technology.
More informationEN FULL DETAILS. SKR Vandal Resistant keypad Full Details. Passion.Technology.Design.
EN FULL DETAILS SKR Vandal Resistant keypad Full Details Passion.Technology.Design. Warnings When installing the apparatus, please respect to the letter all instructions provided by the supplier and in
More informationGV-Card Reader. User s Manual
GV-Card Reader User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. READER-B 2016 GeoVision, Inc. All rights
More informationOSM Features: Field Configurable Reader,I/O to OSDP OSDP to Panel
OSM-1000 Universal OSDP Interface Module Series Features: Field Configurable Reader,I/O to OSDP OSDP to Panel Interfaces and Formats Wiegand ( 4 to 300 bits) F/2F (Binary, ABA) Strobed ( Wiegand, ABA )
More informationSINGLE READER EXPANSION MODULE
SINGLE READER EXPANSION MODULE INSTALLATION GUIDE A D C - A C X 1 TR- SINGLE READER EXPANSION MODULE The ADC-ACX1 Single Reader Expansion Module provides a solution for interfacing to a one Wiegand reader
More informationUC-2000 Installation Manual Unicorn Computers Technology Limited
UC2000 Installation Manual Copyright 2003. All rights reserved. Table of Contents Specifications 2 Enclosure for the UC2000 Controller 3 Unicorn Access Control System Configuration 4 UC2000 Controller
More information1. Product Specification
1. Product Specification Item Specification Voltage 12VDC +10%, Current 1.2A Lock Relay 12VDC/2A Environmental Temperature working:0 ~45 ; storage:-10 ~55 Relative humidity working:40%~90%rh; Card Capacity
More informationSpecifications: Features:
ROFU Features: Applicable card mode EM Card / Key Fob 1 Administrator and 200 Users 200 Proximity Cards / Key fobs Access Modes:Use Bluetooth smartphone or Card / Key fob to access Built-in Tamper alarm
More informationACTpro Single Door IP Controller. Operating & Installation Instructions
ACTpro 1500 Single Door IP Controller Operating & Installation Instructions 18-00079 Issue 1 This manual refers to the ACTpro 1500 a TCP/IP based control unit supporting up to 32 doors. Access Control
More informationGV-AS Controller. Installation Guide
GV-AS Controller Installation Guide Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. 2011 GeoVision, Inc. All rights reserved.
More informationVIDI-AC-2CS Access Controller/ Reader
VIDI-AC-2CS Access Controller/ Reader User Manual CONTENTS INTRODUCTION 2 INSTALLATION.4 STANDALONE MODE 6 CONTROLLER MODE.11 WIEGAND READER MODE.. 13 ADVANCE APPLICATION..14 1 INTRODUCTION The VIDI-AC-2CS
More informationEN TECHNICAL MANUAL. Audio module Art and Art. 1622L
EN TECHNICAL MANUAL Audio module Art. 1622 and Art. 1622L Warning Install the equipment by carefully following the instructions given by the manufacturer and in compliance with the standards in force.
More informationCV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions
CV-550SPK V2 Waterproof Keypad/Reader/Controller Installation Instructions Packing List NAME MODEL/SIZE QTY Self tapping screw 0.15 x 1.06 (4mm 27 mm) Rubber plug 0.23 x 1.2 (6mm 30 mm) Star screw driver
More informationPRO3200 Professional Modular Access Control Hardware
PRO3200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO3200 professional modular access control hardware is an advanced access control panel capable of providing
More informationB100PROX-MF-SA Standalone Biometric Mifare Reader USER S MANUAL. Relay1 time (for Relay 1 in B100PROX-MF-SA,RU2, RTT and DINRTT )
11.9 Set Door Relay Time Relay1 time (for Relay 1 in B100PROX-MF-SA,RU2, RTT and DINRTT ) Relay2 time (for Relay 2 in RU2, DINRTT Remote Relay Unit) B100PROX-MF-SA Standalone Biometric Mifare Reader Swipe
More informationMR52 READER INTERFACE
IN IN2 IN3 IN4 INPUTS IN5 IN6 IN7 IN8 C www.mercury-security.com 2355 MIRA MAR AVE. LONG BEACH, CA 9085-755, (562)986-905 FAX (562) 986-9205 MR52 READER INTERFACE Installation and Specifications: This
More informationSingle Door Standalone Access Control User Manual
Single Door Standalone Access Control User Manual Reading this manual carefully before install and use the device 1. Packing List Name Quantity Remarks Keypad User manual Screw driver Rubber plug Self
More informationOperation manual For NG BIOSINGLE Version 1.1
Operation manual For NG BIOSINGLE Version 1.1 SMART-I ELECTRONICS SYSTEMS PVT. LTD.(An ISO 9001:2008 certified company) R&D, Training & Customer Support Center: First Floor, Arihant Plaza Phase II, Village-Ovala,
More informationgenesis TECHNICAL MANUAL Two-Door Controller GEN-045
Two-Door Controller GEN-045 Genesis Electronics Australia Pty Ltd www.genesiselectronics.com.au info@genesiselectronics.com.au Australian Owned, Designed and Manufactured Distributed By:- Genesis reserves
More informationC5S120 Installation and Connection Guide
C5S120 Installation and Connection Guide Version: V1.1 1. Cautions Please note the following cautions. Mis-operation may lead to personal injury or equipment failure: 1) Do not energize the system before
More informationIndoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range
Indoor/Outdoor Proximity Reader and Keypad with 10cm (4in) Read Range Stand alone CR-R885-SB Installation and Operating Instructions V1.1 TABLE OF CONTENTS Installation... 2 Mounting and Wiring... 2 Mounting
More information900-4RL Option Board. Refer to installation instructions for compatible supply models - PS902, PS904, PS906, and PS914. Note
*44487080* 44487080 DANGER To avoid risk of electric shock, turn off AC power to power supply before installing or wiring option board. 900- Option Board Installation Instructions 900- Specifications Inputs
More informationGV-EL124S Electric Strike
GV-EL124S Electric Strike Featured with a built-in door status sensor, the GV-EL124S is a fail-secure electric strike, but it is field convertible from fail secure to fail safe. It can be mounted either
More informationSfera Keypad Module. Installer manual 07/12-01 PC
353000 Sfera Keypad Module Installer manual 07/12-01 PC 2 Contents Sfera Keypad Module Installer manual 1 Introduction 4 1.1 Warnings and recommendations 4 2 Description 5 2.1 Main functions 5 2.2 Front
More informationINSTALLATION GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control
STALLATION GUIDE.4 Inch TFT Terminal Time Attendance & Access Control Optional accessories Safety Precautions The following precautions are to keep user s safe and prevent any damage. Please read carefully
More informationCYPRESS " " EXP SPX Expansion interface! modules EXP-2000_MAN_0314
CYPRESS EXP-2000 SPX Expansion interface! modules The EXP-2000 provides additional Door/Panel interface points to most SPX products. The EXP-2000 uses a local RS-485 network through an SPX gateway device.
More informationXP-KIT. Programming & Operations. Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations
9800 XP-KIT Programming Starter Kit for Aiphone -XP Series Proximity Reader Stations Programming & Operations Manual KIT CONTENTS: Programming Keypad Programming Master Card Pack 0 Blank Proximity Cards
More informationDINB100-SA-KIT Standalone Biometric Kit
DINB100-SA DINRTT DINB100-SA-KIT Standalone Biometric Kit User Manual v.b3 Contents 1.0 INTRODUCTION... 3 2.0 MOUNTING AND DISMOUNTING... 3 3.0 SPECIFICATIONS... 3 4.0 APPLICATION DIAGRAM... 4 5.0 WIRING...
More informationCV-110SPK Standalone Keypad/Prox Access Control Installation Instructions
CV-110SPK Standalone Keypad/Prox Access Control Installation Instructions 1. Packing List Qty Name Remarks 1 1 1 2 2 1 Keypad User manual Screwdriver Wall plugs Self-tapping screws Torx screw 0.8 x 2.4
More informationDINB100-SA Standalone Biometric Reader
a Visual Plus Corporation Company EN DINB100-SA Standalone Biometric Reader User Manual v.a1 Contents 1.0 INTRODUCTION... 2.0 MOUNTING AND DISMOUNTING... 3.0 SPECIFICATIONS... 4.0 APPLICATION DIAGRAM 5.0
More informationQUICK START GUIDE. 2.4 Inch TFT Terminal Time Attendance & Access Control
QUICK START GUIDE 2.4 Inch TFT Terminal Time Attendance & Access Control Safety Precautions The following precautions are to keep user safe and prevent any damage. Please read carefully before installation.
More informationInstruction Manual. Vogue. Security. Technology. Innovation 2013-V01
Instruction Manual DH16A-60DTE Model 60 with plastic keypad, stand alone access control DH16A-60DTQE Model 60 with plastic keypad, networked access control 2013-V01 Security Technology Vogue Innovation
More informationCLASS I CLASS I AUTONOMOUS PROXIMITY READER INSTALLATION MANUAL AUTONOMOUS PROXIMITY READER INSTALLATION MANUAL ENGLISH ENGLISH
CLASS I AUTOMOUS PROXIMITY READER PROXIMITY ACCESS CTROL INSTALLATI MANUAL ENGLISH CLASS I AUTOMOUS PROXIMITY READER PROXIMITY ACCESS CTROL INSTALLATI MANUAL ENGLISH CGRATULATIS YOUR PURCHASE OF THIS QUALITY
More informationWiring Guide EP.NMINI. Version 1.02 Last Updated:
Wiring Guide EP.NMINI Version 1.02 Last Updated: 14-10-2014 1 Note: See http://www.entrypass.net/ for updates, revisions, and download the latest installation manual There are currently 2 version of EntryPass
More informationKeypad CT2000. Art. No.: , (black) Art. No.: , (white) Installation Manual
secure open Keypad CT Art. No.:, (black) Art. No.:, (white) Installation Manual CT_installation_ENGmay Conlan ApS Speditorvej A DK- Aalborg Tel: + Fax: + www.conlan.eu info@conlan.eu Table of contents.
More informationIF-80x Outdoor Terminal
95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope
More informationIEI emerge MicroNode Install and Setup Guide. Contents
IEI emerge MicroNode Install and Setup Guide Contents Connecting power and the network to the MicroNode... 2 Using Power over Ethernet (PoE)... 3 or... 3 Using a 12 VDC power supply... 3 Connecting and
More informationUNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R. 1. Features. 2. Installation and start-up
UNIVERSAL EXPANDER FOR CARD / CHIP READERS INT-R int-r_en 09/11 The INT-R expander interfaces with the INTEGRA and CA-64 alarm control panels, replacing the previously offered CA-64 SR and CA-64 DR expanders.
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationInstallation & User Manual
Contents Installation Instructions 3 Installation Diagrams 4 System Overview 6 Wiring Diagrams 8 Network Diagrams 9 Operation Instructions Fingerprint Enrollment 12 21 Wi-Enterprise Controller www.transmittersolutionssmart.com
More information2000 Series e/em Style Keypad Installation and Programming Manual
2000 Series e/em Style Keypad Installation and Programming Manual Document Number: 6054022 Revision: 0 Date: 12/21/06 Table of Contents Table of Contents Section 1: Introduction... 6 1 Product Description...6
More informationEP1501 Intelligent Controller
J6 BT K K2 TB5 TB 2.35 [59.69] 2.75 [69.85] EP50 Intelligent Controller with Paired Reader Interface for One Physical Barrier Installation and Specifications: www.mercury-security.com 2355 MIRA MAR AVE.
More informationCV-945 Stand-Alone Biometric Reader. Installation Instructions
CV-945 Stand-Alone Biometric Reader Installation Instructions Contents 1.0 Introduction... 03 2.0 Mounting... 03 3.0 Specifications... 04 4.0 Application Diagram... 04 5.0 Wiring... 05 6.0 Recommended
More informationCRC220 and CRC221 INSTALLATION GUIDE. REF No.: DOC0014 ISSUE: 09
CRC220 and CRC221 INSTALLATION GUIDE REF No.: DOC0014 ISSUE: 09 30th July 2015 2 Contents CRC220 & CRC221 INSTALLATION GUIDE 1. Scope 1-1 2. Introduction 2-1 2.1 Features 2-1 2.1.1. PCB Features 2-1 2.1.2.
More informationINSTALLATION INSTRUCTIONS 920P EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920P EntryCheck TM The EntryCheck 920P Indoor/Outdoor Keypad is a surface-mount
More informationWaterproof. Keypad/Reader/Controller
Waterproof Keypad/Reader/Controller User Manual W1-C W3-C User manual 1. Packing List Name Quantity Remarks Digital Keypad-W1-C/W3-C 1 User manual 1 Screw driver 1 Rubber bungs 4 6*27mm, used for fixing
More informationACCESS CONTROL QUICK INSTALL GUIDE. tel: +44 (0) fax: +44 (0) web:
ACCESS CONTROL QUICK INSTALL GUIDE tel: +44 (0)1457 874 999 fax: +44 (0)1457 829 201 email: sales@cop-eu.com web: www.cop-eu.com WIRING CONFIGURATION - ACS CONTROLLERS CONNECTIONS Dahua access controllers
More informationIPassan Installation guide
IPassan Installation guide 1 Content 1 Overview... 3 1.1 Features... 3 1.2 Hardware... 3 1.2.1 s... 3 1.2.2 Extra modules... 5 1.3 IPassan manager... 7 2 Installation... 7 2.1... 8 2.1.1 Power supply...
More informationRFT1000 reader in RACS 5. User Manual
Roger Access Control System RFT1000 reader in RACS 5 User Manual Firmware version: 1.3 or newer Hardware version: 1.1 Document version: Rev. A 2016 ROGER sp. z o.o. sp.k. All rights reserved. This document
More informationPRO2200 Professional Modular Access Control Hardware
PRO2200 Access Control Hardware As a part of the WIN-PAK software controlled hardware family the PRO2200 professional modular access control hardware is an advanced access control panel capable of providing
More informationInstallation & User Manual V2.08
YOUR SECURITY IS OUR PRIORITY Other products from GSD Contents Installation Instructions Installation Diagrams System Overview Wiring Diagrams Network Diagrams Operation Instructions Fingerprint Enrollment
More informationINSTALLATION INSTRUCTIONS 920 EntryCheck TM
801 Avenida Acaso, Camarillo, Ca. 93012 (805) 494-0622 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 920 EntryCheck TM The EntryCheck 920 Indoor/Outdoor Keypad is a surface-mount
More informationACX Series. Access Controller for Ethernet
Access Controller for Ethernet The controllers are the industry s most powerful all-in-one access controllers designed for both critical government and private sector security applications. 0 Features
More informationEX8. User Manual. Ver 1.0
EX8 User Manual Ver 1.0 EX8 manual ver1.0 Power supply important issue! Use separate power supply when ever is possible, one for EX8 and Reader and another for door lock. This way electrical isolation
More informationINSTALLATION GUIDE BioEntry Plus English Version 2.11 EN BEP V2.11A
www.supremainc.com INSTALLATION GUIDE English Version 2.11 EN 101.00.BEP V2.11A Contents Safety Instructions... 3 Getting Started... 4 Components... 4 Features... 5 Part names and features... 5 Cables
More informationF7_F707_F708 Installation Instruction V1.0 F7_F707_F708. Access Control Terminal. Installation Instructions
F7_F707_F708 Access Control Terminal Installation Instructions Revised May 2008 About this Guide This guide provides installation instructions only. For information regarding actual operation and configuration
More informationAccess Terminal IF-800
95-10287 IF-800_1312_3 Access Terminal IF-800 1 Slave Terminal IF-800 Thank you for using a terminal of the series IF-800 for recording access data. Scope of Delivery: Slave terminal IF-800. I/O controller
More informationStandalone Keypad Access Control. User Manual. Please read the manual carefully before use this unit
Standalone Keypad Access Control User Manual Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver 1 Φ20mm 60mm,Special for keypad
More informationStandalone Keypad Access Control. User Manual. SS-TS2000 Size:120*80*25 mm
Standalone Keypad Access Control User Manual SS-TS2000 Size:120*80*25 mm Please read the manual carefully before use this unit 1. Packing List Name Quantity Remarks Keypad 1 User manual 1 Screw driver
More informationRBR-SB-KTZ001 LAR 2. User Manual
RBR-SB-KTZ001 LAR 2 User Manual INTRODUCTION KTZ001 is a compact, waterproof stand-alone programmable access control system that provides proximity entry for up to 2000 users. Read both EM and HID card.
More informationInstallation Instructions (KF-2000)
VERSION 2005. 10 Installation Instructions (KF-2000) Keico Hightech, Inc. Installation Instructions KF-2000 Keico Hightech Ace Twin Tower I 12 th FL 212-1, Guro-Dong, Guro-Gu Phone +82-2-853-9000 Fax +82-2-830-7809
More informationADVANTAGE DKE QUICK START GUIDE. 2 Make sure you have everything shown here. 3. What s what? All important internal components labeled for you
1 of 6 START HERE 1 Carefully unpack box. 2 Make sure you have everything shown here. 3 Unlock and remove front panel of keypad unit, then using carriage bolts and hex nuts, attach unit to pedestal as
More informationImproX IXP20 Controller INSTALLATION MANUAL
MODEL NUMBER: ISC920-0-0-GB-XX ISC921-5-0-GB-XX IXP20 CONTROLLER SPECIFICATIONS Working Environment Plastic Housing... Power ImproX IXP20 Controller INSTALLATION MANUAL Designed to work in an indoor (dry)
More informationQuick Start Guide. GV-AS / EV Controller
Quick Start Guide GV-AS / EV Controller Thank you for purchasing GV-AS / EV Controller (GV-AS100 / AS110 / AS120 / AS210 / AS400 / AS410 / AS810 and GV-EV48). This guide is designed to assist the new user
More informationHI SEC Integrated Systems
Service Note 145 HI SEC Integrated Systems Subject: New S-ART 2xx Range Ref. No.: 93014501 Service Note 145 Summary: This Service Note describes a new enhanced range of S-ART s which will replace the existing
More informationSmartLock Controller INSTALLATION MANUAL
SmartLock Controller INSTALLATI MANUAL November 2015 Table of Contents INTRODUCTI... 3 Diodes... 4 Terminal Strips and Cable... 5 SPECIFICATIS... 6 SMARTLOCK CTROLLER LAYOUT... 8 LED Indicators... 9 Mounting...
More informationSL2000E. Status Output. Electronic Code Lock. Features. Input. Exit Button Input. Introduction. Door Contact Input. Functional Description.
SL2000E Electronic Code Lock Features Door Relay output Status transistor output Aux transistor output Door Contact input Exit Button input INSTALLER code for programming MASTER code for arming/disarming
More informationAmano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL
MODEL NUMBER: XRT910-0-0-AC-XX XRT920-0-0-AC-XX AMANO itrt Amano (itrt) Intelligent Twin Reader Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment Plastic Housing... Power Designed to work
More informationGV-AS/EV Controller. User s Manual
GV-AS/EV Controller User s Manual Before attempting to connect or operate this product, please read these instructions carefully and save this manual for future use. AS100.110.120.210.400.410.810-EV48-C
More informationSuprex RF Series CYPRESS. Operations Manual. Suprex Reader Extender - RF Wireless Interface EXP SPX Mhz SPX-5521_MAN_0316
CYPRESS Suprex RF Series Operations Manual Suprex Reader Extender - RF Wireless Interface EXP-2000 SPX-5521 900 Mhz SPX-5521_MAN_0316 Cypress Suprex SPX-5521 Series Overview This manual covers the operation
More information7612 Programming Instructions
7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards 7612 is a vandal resistant proximity card and keypad access control
More informationGV-RK1352 and GV-R1352 Card Reader
GV-RK1352 and GV-R1352 Card Reader The GV-RK1352 and GV-R1352 are card readers designed to recognize identifications cards. GV-RK1352 comes with keypad, allowing it to also recognize PIN codes. Featured
More informationIBA-7612 Programming Instructions
IBA-7612 Programming Instructions Built-in Proximity reader Read Range 65mm odulation ASK at 125kHz Compatible Cards ALL 26-Bit EM Cards IBA-7612 is a vandal resistant proximity card and keypad access
More informationINSTALLATION INSTRUCTIONS 921P EntryCheck TM
80 Avenida Acaso, Camarillo, Ca. 90 (805) 494-06 www.sdcsecurity.com E-mail: service@sdcsecurity.com INSTALLATION INSTRUCTIONS 9P EntryCheck TM The EntryCheck 9P Indoor/Outdoor Keypad is a surface mount
More informationW3-M. Metal waterproof standalone access control/reader. User Manual
W3M Metal waterproof standalone access control/reader User Manual Name Digital Keypad W3M User Manual Screw driver Rubber bungs Selftapping screws Diode 1. Packing List Quantity 1 1 1 4 4 1 Remark 6*27mm,
More information4. We recommend that you install the ievo reader at the DDA height of approximately 1 metre. This will be the perfect height for finger placement.
WELCOME ievo would like to thank you for purchasing our product. This manual is designed to make your installation of our superior biometric reader quick, easy and efficient. Please ensure you check all
More informationN-1000-II. Installation & Programming Manual. Version rev. 2.0
Installation & Programming Manual Version 8.0 September 1998 TD1062 rev. 2.0 Notices Fire Safety Notice: Never connect any card reader devices or locks to doors, gates or barriers without first consulting
More information