ABB Fieldbus Infrastructure and Network Devices An overview

Size: px
Start display at page:

Download "ABB Fieldbus Infrastructure and Network Devices An overview"

Transcription

1 ABB Fieldbus Infrastructure and Network Devices An overview ABB

2 ABB fieldbus devices Industrial automation with the fieldbus Fieldbus technology is becoming increasingly important throughout industry. This isn t really surprising as the principle behind it is as simple as it is ingenious: in addition to supplying connected devices with power, the fieldbus for process automation is also used to process purely digital communication between the field and the process control system. This makes it possible to partially relocate open-loop and closedloop control functions within the hierarchy from the system to the field devices, therefore allowing system optimization functions at the higher system level to be put to better use. ABB systems and components ABB has a reputation as a successful equipment supplier offering a wide range of tried and tested systems for industrial automation. This brochure contains information about ABB s range of fieldbus components with specific functionality that can be used for both fieldbuses PROFIBUS and FOUN DATION Fieldbus. These two bus systems are the accepted fieldbus standards in the automation sector. The following topology examples for PROFIBUS and FOUNDATION Fieldbus indicate possibilities for using the following fieldbus devices: Examples of system topology with PROFIBUS Control network AC 870P AC 800F AC 800M PROFIBUS DP PROFIBUS Barrier BI 913S LD 800P Profibus EExi S900 I/O PROFIBUS PA Fieldbus Barrier FB 900 series S900 CB 220 Compact Box PA device 2 ABB

3 Overview of the devices presented below: Thanks to their interoperability, the devices presented in this brochure facilitate the task of project planning for the fieldbus and prevent communication errors. Both physically and in terms of functionality, ABB s fieldbus components are ideally prepared for their specific use in the field. Depending on the device, using ABB fieldbus devices delivers the following advantages: The bus segment is protected against communication errors and short-circuits EEx i field devices can be connected during operation No further T boxes or distribution boxes are needed A higher supply voltage and a higher supply current are made available, therefore increasing the segment length and making it possible to connect up to 32 field devices to a single segment Fieldbus Barrier page 4 Series FB 900-S Power Conditioner page 6 PC 900-NR FOUNDATION Fieldbus Linking Device page 8 LD 800HSE PROFIBUS DP/PA Linking Device page 10 LD 800P PROFIBUS Redundancy Linking Module page 14 RLM01 Annex A: Grounding and shielding page 16 Annex B: Introduction to intrinsic safety page 18 Examples of system topology with FF Control network AC 800F AC 800M FF HSE network LD 800HSE Power Conditioner PC 900-NR H1 link Fieldbus Barrier FB 900-series Max. 4 Fieldbus Barriers H1 devices ABB 3

4 Feldbus Barriere, series FB 900-S The Fieldbus Barrier series FB 900-S can be used to connect up to four intrinsically safe fieldbus stations. They are connected, using non-intrinsically safe ports, to the trunk of a fieldbus with physical bus characteristics according to IEC A Fieldbus Barrier works exclusively on the physical level, making it independent of the protocol. As a result, it can be used for any fieldbus with physical bus characteristics according to IEC , i.e. for FOUNDATION Fieldbus and PROFIBUS PA, for example. The Fieldbus Barrier performs the following tasks: Option of connecting intrinsically safe (EExi) field devices Feeding of field devices connected at the outputs Assurance of electrical isolation between the fieldbus segment that is not intrinsically safe (fieldbus trunk) and the intrinsically safe spur outputs Protection against short-circuits at the intrinsically safe spur outputs Using the Fieldbus Barrier has the following advantages: Interference-free communication: As a result of the short-circuit current restriction at the output, only the output concerned fails in the event of a line short-circuit between the Fieldbus Barrier and the field device. The fieldbus segment continues to work and communication at this bus line can therefore be maintained without interruption with all other stations. High availability: The EExi field device connection makes it possible to exchange field devices during operation. Reduction of repeaters/linking Devices: Only Power Repeaters/Linking Devices without an intrinsically safe interface are needed. Reduction of distribution boxes: The Fieldbus Barrier meets the requirements of protection classes IP66 and IP67. It replaces the T-Trunk connection box needed for conventional fieldbus wiring. Cascading/continuation of the fieldbus is possible. Thanks to internal, switchable termination, there is no need for additional assembly of external active fieldbus scheduling. H1 link PROFIBUS DP Fieldbus Barrier FB 900 series LD 800P PROFIBUS PA H1 devices Fieldbus Barrier FB 900 series The Fieldbus Barrier in a FOUNDATION Fieldbus environment PA devices 4 The Fieldbus Barrier in a PROFIBUS environment ABB

5 High operational reliability: As a result of using the Increased safety protection type, the maximum permissible current on the EExe side is only limited by the Power Conditioner (in the case of FOUNDATION Fieldbus) or Linking Device (in the case of PROFIBUS PA) that is used. As a result, by using the Power Conditioner or the Linking Device in conjunction with the Fieldbus Barrier, a larger number of field devices can be connected to a single segment without affecting operational reliability. Electrical isolation: As a result of the electrical isolation between the field devices and the system, the need for equipotential bonding is eliminated. Simplified ex-loop check: The Fieldbus Barrier meets the requirements of the FISCO model (see page 18). This means that there is no need to test EExi loops with regard to hazardous areas when FISCO field devices are used. Based on the FB 900-S series, ABB offers three different types of Fieldbus Barrier All types of Fieldbus Barrier have EExe terminal units for the fieldbus and additional EExi terminal units for connecting up to four field devices. They can be assembled directly in hazardous areas (Zone 1 or Zone 2 in accordance with ATEX). FB 900-SA4 in the field housing, made of aluminum, for direct field assembly on a wall or on armatures with cable entries made of plastic. FB 900-SB4 in the field housing, made of stainless steel, for direct field assembly on a wall or on armatures with cable entries made of stainless steel. FB 900-SR4 without field housing, for assembly on a 35 mm top-hat rail in accordance with EN in a cabinet or field housing. ABB 5

6 Power Conditioner PC 900-NR As standard, the PC 900-NR Power Conditioner delivers a 24 V d.c. power supply for fieldbus networks. In addition, it ensures the necessary impedance matching for networks in accordance with IEC / ISA S50.02 (FOUNDATION Fieldbus). The PC 900-NR Power Conditioner can be used for fieldbuses which are not operated intrinsically safely for explosion protection for instance in the case of non-hazardous applications or installations with explosion protection with an increased level of EExe safety. The PC 900-NR Power Conditioner is assembled outside the hazardous area. If it is used in conjunction with the Fieldbus Barrier (see pages 4-5), EExi signals can also be connected. The Power Conditioner supplies the H1 link with a current of up to 1 A. It has integrated termination, two LEDs to display the current and errors (overload, short-circuit, low voltage), and removable terminals to simplify installation. To the field devices H1 segment with 1 A Using the Power Conditioner has the following advantages: H1 host Flexible fieldbus segment structure: As a current of 1 A is supplied, the fieldbus length can be increased and the theoretically permissible number of up to 32 field devices can be connected. This theoretical number is only limited by the bus timing. High availability: Using the Power Conditioner in conjunction with the Termination Unit or Power Feed Modules simplifies the wiring and, as a result of the high MTBF time of the Power Conditioner, increases the reliability of the fieldbus. Simplified topology structure: The Power Conditioner has a bus terminator that can be connected and switched off. 24 V d.c. Error output 6 ABB

7 Example of a Power Conditioner with a Power Rail with a redundant power supply via redundant Power Feed Modules To the field devices H1 segment at 1 A each Power Conditioner Power Feed Module Redundant Power Feed Module Power Rail Optional: redundant 24 V d.c. input 24 V d.c. 24 V d.c. Error output Error output The following components are Power Conditioner accessories, which can be used to simplify assembly and increase availability Power Feed Module A PF 900-NR Power Feed Module provides the power supply for the Power Conditioner. It is only needed when the Power Rail is used. Use of the Power Feed Module has the following features: A redundant power supply can be provided for the Power Conditioner. The 24 V d.c. voltage is made available via the internal wiring. Device redundancy with integrated monitoring is possible. Power Rail The PR 900-NR Power Rail is a voltage distribution rail for the Power Conditioner. Its size allows it to be fitted on a standardized DIN rail without additionally attaching the rail. Termination Unit The TU 900-NR4 Termination Unit contains the PR 900-NR Power Rail and the terminals for the H1 links, for the error messages, and for the redundant external 24 V d.c. power supply. The Termination Unit can be used to mount up to four PR 900-NR Power Conditioners and up to two PF 900-NR Power Feed Modules. It simplifies the task of integrating the devices while at the same time reducing the amount of wiring involved. The availability of the H1 link fieldbus segment can be increased by using a Termination Unit with Power Conditioners and Power Feed Modules. This allows Power Feed Modules to be made redundant and provides a means of redundantly connecting external 24 V d.c. power supplies. ABB 7

8 FOUNDATION Fieldbus Linking Device LD 800HSE LD 800HSE serves as a gateway between the FOUNDATION Fieldbus field devices on H1 links and High Speed Ethernet (HSE Subnet). The provision of data from an H1 link to the HSE Subnet as well as from one H1 link to another is guaranteed by the cyclical communication typical of FOUNDATION Fieldbus between field devices on various H1 links and field devices on the HSE Subnet. In addition, the client/server gateway allows function blocks in H1 devices to be accessed via the HSE interface. LD 800HSE is also designed for redundant use, with the relevant H1 outputs for two Linking Devices being connected to an H1 link. The redundant Linking Devices are interconnected via a serial interface for the purpose of exchanging redundancy information. LD 800HSE is mounted on a DIN rail and corresponds to protection class IP 20. The LD 800HSE allows users to access devices on the FOUNDATION Fieldbus (FF) H1 link via High Speed Ethernet from control system consoles or from central management consoles. The LD 800HSE allows reports and alarms to be distributed from H1 devices. It works as a Link Master for each H1 link with the Link Active Scheduler (LAS) functionalities as the basis for publisher/subscriber communication scheduling. The integrated Web server allows diagnostic data and functions to be accessed remotely using a Web browser. The design of FOUNDATION Fieldbus Linking Device LD 800HSE corresponds to class 42c of the HSE profile and is registered with the Fieldbus Foundation1). Data exchange between H1 links of the same Linking Device as well as between those of different Linking Devices is carried out via publish/subscribe mechanisms and does not require any IEC controller configurations. IEC controllers can be coupled via HSE interface modules. Thanks to its simple assembly and connection technology, the LD 800HSE is quite easy for users to work with. Comprehensive diagnosis options are made possible by the device s communication and status displays as well as the integrated Web server. In addition, the various certifications guarantee that international standards are adhered to, thus ensuring that they can be integrated smoothly into systems. Functions and benefits: Connection between FOUNDATION Fieldbus High Speed Ethernet (HSE) and up to four H1 links Configuration of the connected H1 devices Access to the function blocks in the H1 devices (client/server) 4 independent H1 Link Masters (LAS) Publish/subscribe (H1) (with up to 4 sub-cycles) Transfer of data from one H1 link to another Transfer of data between H1 and HSE Update of the firmware using download mechanisms Redundancy thanks to a second Linking Device with automatic data synchronization via a serial interface 1) LD 800HSE is registered as a class 42a device because the foundation does not offer class 42c registration at present. 8 ABB

9 Technical data for FOUNDATION Fieldbus Linking Device LD 800HSE Power supply Supply voltage 24 V d.c. (+- 20%) Current consumption Structure Dimensions Weight Protection rating Ambient conditions Operating temperature Storage temperature Relative humidity Ethernet interface HSE Number of channels 1 Port Transfer rate Fieldbus interface H1 Number of H1 channels 4 Port Physical layer profile Transfer rate Serial interface Port Certifications Accessories 200 ma (height x width x depth) 131 x 47 x 111 mm approx. 0.4 kg IP20 0 C C, non-vertical mounting and any impairment in air convection may reduce the upper temperature limit -20 C C < 90%, non-condensing Ethernet 10BASE-T/100BASE-TX, RJ45 10 Mbit/s or 100 Mbit/s (auto-sensing) FF H1 3-pole screw terminal (pluggable), functionally isolating FF-816, type 114 separately powered, not intrinsically safe kbit/s 1 x 9-pole SubD pin (male) RS-232, kbit/s CE in accordance with EMC Directive 89/336/EEC EN , EN FCC Part 15 Subpart B Class A VCCI Class A Information Technology Equipment (ITE) ULC ABB Industrial IT enabled Redundancy link cable 0.5 m (to be ordered separately) ABB 9

10 PROFIBUS DP/PA Linking Device LD 800P Linking Devices are needed to connect PROFIBUS DP to PROFIBUS PA. The LD 800P Linking Device converts the physical bus characteristics of the RS 485 interface for the PROFIBUS DP into PROFIBUS PA physical bus characteristics according to IEC , enables connected PROFIBUS PA devices to be supplied with power via the bus, and allows use in hazardous areas if so required. The LD 800P is a modular Linking Device consisting of a Head Station and Power Link Modules. The Head Station, which is used to convert the PROFIBUS DP protocol to PROFIBUS PA, is available in three models: HS 810: 1-channel HS 820: 2-channel HS 840: 4-channel, with the additional feature that it supports line redundancy on the PROFIBUS DP side The PL 810 and PL 890 Power Link Modules supply the connected PROFIBUS PA devices with power via the fieldbus line, which means that the field devices do not require an external power supply and costs are therefore reduced. The PL 890 Power Link Module offers an intrinsically safe connection in accordance with [EEx ia] IIC and is approved in line with FISCO (see Annex). Both types of Power Link Module integrate bus termination and can be operated in parallel on a Head Station. 10 ABB

11 These five different modules allow PROFIBUS PA segments to be set up flexibly in such a way as to maximize performance and minimize costs. Up to five Power Link Modules can be connected to one of the Head Station s PROFIBUS PA channels, making it possible to set up a maximum of 20 PROFIBUS PA segments. All modules are mounted on a DIN rail and are approved for operation and installation in Zone 2 hazardous areas in accordance with CENELEC. All standardized PROFIBUS DP transmission rates of kbit/s to 12 Mbit/s are recognized and supported automatically. Properties The LD 800P Linking Device works transparently, which means that neither the PROFIBUS DP nor the PROFIBUS PA consider LD 800P to be a station. As a result, it is not necessary to address, configure, or parameterize the Linking Device. The optionally redundant PROFIBUS DP connection allows high availability in terms of the communications networks. The Power Link Modules integrate a Power Conditioner separating data communication from the bus power supply. Depending on the available power, up to 400 ma can be fed to the PA segment using PL 810 and up to 100 ma can be fed using PL 890, which is certified in accordance with FISCO. Devices that are certified in accordance with FISCO are proven to be intrinsically safe and can be used in a plant s hazardous areas without the need for additional calculation effort. In addition, the Power Link Modules possess an integrated bus terminator, which terminates the PROFIBUS PA line unilaterally. There is therefore no need for a separate bus terminator on the Power Link Modules. The fieldbus and power terminals that are located on the modules are electrically isolated from one another. Universal The LD 800P PROFIBUS DP/PA Linking Device can be used in all ABB systems and in all non- ABB systems that support PROFIBUS: System 800xA Freelance 800F AC 870P/Symphony Melody Advant Master Non-ABB systems, such as PLC with a PROFIBUS interface Advantages for the customer The LD 800P PROFIBUS DP/PA Linking Device is a simple solution for connecting PROFIBUS PA devices to ABB process control systems or to PCSs from other manufacturers. Thanks to the fact that it is easy to assemble and connect, users are offered easy handling as well as extensive diagnostic options using the communication and status displays located on the device. In addition, the various certifications guarantee that international standards are adhered to, therefore ensuring smooth operation in systems. ABB 11

12 PROFIBUS DP/PA Linking Device LD 800P Technical data for the HS 810, HS 820, and HS 840 Head Stations Rated operational voltage Rated normal current V DC Ripple < 10 % Power dissipation Electrical isolation PROFIBUS DP fieldbus connection ma (without load) 3 W Functional insulation, rated insulation voltage 50 V mns 9-pol. Sub-D jack (RS 485), for HS 840 also redundant Fieldbus standard PROFIBUS DP/V1 in line with EN 50170/2 Baud rate Electrical isolation EN Electromagnetic compatibility EC Guidelines Standards 45,45 kbit/s Mbit/s NAMUR NE 21 89/336/EWG EN Ambient temperature C ( K) Relative humidity < 75 % Connection type Terminals Core cross-section Up to 2,5 mm 2 Casing Weight Protection rating in line with DIN Data relating to use in hazardous areas Approval for Zone 2 Group, category, protection type Explosion protection EC Guidelines Standards 60 mm x 115 mm x 107 mm 250 g IP20 TÜV 02 ATEX 1888X Ex II 3 G EEx n A II T4 EG94/9 EN HS 810, HS 820, and HS 840 Head Stations PL 810 and PL 890 Power Link Modules Power Link Modules for use in hazardous areas 12 ABB

13 Technical data for the PL 810 and PL 890 Power Link Modules Rated operational voltage Rated normal current V DC Ripple < 10 % Electrical isolation 790 ma ma PROFIBUS PA In line with IEC PL 810/PL 890 rated operational voltage PL 810/ PL 890 rated normal current Terminating impedance Protocol Baud rate Functional insulation, rated insulation voltage 50 V mns V DC/12, ,4 V DC < 400 ma/< 100 ma 100 ohms integrated PROFIBUS PA 31,25 kbit/s Electrical isolation EN Protection rating IEC/EN Electromagnetic compatibility EC Guidelines Standards NAMUR NE 21 89/336/EWG EN Ambient temperature C ( K) Relative humidity < 75 % Connection type Terminals Core cross-section Up to 2,5 mm 2 PL 810/PL 890 casing PL 810/PL 890 weight Protection rating in line with DIN Data relating to use in hazardous areas Approval for Zone 2 Group, category, protection type Explosion protection EC Guidelines Standards Also for PL 890: Group, category, in line with EC94/9 Protection type U o voltage I o current P o power 80 mm x 115 mm x 107 mm/100 mm x 115 mm x 107 mm 320 g/430 g IP20 TÜV 02 ATEX 1886X/TÜV 02 ATEX 1887X Ex II 3 G EEx n A IIC T4 EG94/9 EN EX II (1) G D [EEx ia] IIC 15 V 207,2 ma 1,93 W ABB 13

14 PROFIBUS Redundancy Linking Module RLM01 Designing fieldbus lines to be redundant considerably increases the availability of plants or plant components. Module RLM01 provides redundant communication channels for the PROFIBUS protocol. Like an active change-over switch, it transforms a PROFIBUS-DP line into two redundant lines or, conversely, combines two redundant lines to form a single line, as required. This also makes it possible for field devices that are fitted with just one PROFIBUS interface to be integrated into redundant lines. Universal Full redundancy can only be achieved if both the control unit and the field devices support this. However, the RLM01 module can be used universally in any PROFIBUS configuration for instance in order to allow redundant PROFIBUS lines even if the control unit or field devices are not designed to be redundant. Properties Use of PROFIBUS-DP/FMS lines Implementation of a non-redundant PROFIBUS line on two redundant lines and vice versa Automatic line selection Transmission rate of 9.6 kbit/s - 12 Mbit/s Communication monitoring Repeater functionality Redundant power supply Status and error display Power supply monitoring Signaling contact Easy assembly on a DIN mounting rail Application The RLM01 module can be positioned directly after a master, in front of a bus segment with several slaves, or in front of an individual slave. Several PROFIBUS stations with redundant couplers can be connected directly to the PROFIBUS that has been made redundant by RLM01. Stations with just one interface can be positioned either on the A line or on the B line. Each RLM01 PROFIBUS interface can operate up to 31 PROFIBUS stations. 14 ABB

15 Line redundancy: As shown in the diagram, the three interfaces of RLM01 A, B, and M support transmission rates of 9.6 kbit/s to 12 Mbit/s, which are defined for PROFIBUS-DP/FMS. The module reinforces die signal form and amplitude of the data received and monitors all three lines with regard to activity and faults. Any faults that are recognized are indicated with the aid of a LED on the front panel. Suitable messages are available for diagnostic purposes and can be picked up on the 8-pole terminal strip. Splitting a non-redundant line: Data arriving via line M with the correct start of frame is passed in parallel to the other two connections, A and B. If the start of frame is incorrect, the control logic does not output any data at A and B. Either a simple or a redundant power supply with 24 V d.c. is possible as required. The monitoring logic checks whether both voltages are available and reports any malfunction that may occur. Combining redundant lines: The data that arrives first via line A or line B, with the correct start of frame, is forwarded to connection M. If the data arrives at the same time, either line A or line B is selected at random. If the start of frame at A is incorrect, the control logic switches to line B, which is still available and redundant. The procedure is the same in reverse for line B. Line redundancy Master 1 Master 2 RLM 01 O O Line A E E Line B A B Slave 1 RLM 01 Slave 3 R R M Slave 2 Slave 5 K K Slave 4 Slave N ABB 15

16 Annex A: Grounding and shielding Using the Fieldbus Barrier and Power Conditioner devices increases the operational reliability of systems that are fitted with fieldbus technology. When it comes to planning fieldbus topologies in hazardous areas, issues relating to explosion protection must be taken into account. This includes using permissible cable types, observing grounding and shielding regulations, and proving explosion protection. Grounding and shielding the Fieldbus Barrier All cable types that comply with the standard have a shield. For reasons of EMC protection, this shield should be grounded. Use of the Fieldbus Barrier makes it possible to use all recognized shielding and grounding strategies: Hard grounding of the shield on both sides (connection between the shield and equipotential bonding) Capacitive grounding at one end of the shield (connection of the shield to the equipotential bonding via a capacitor), hard grounding at the other end Hard grounding at one end of the shield, no grounding at the other end ABB always recommends the use of shielded lines for the fieldbus. 16 ABB

17 Cabling It is advisable to use the following cable types with the characteristic values listed in the table: Type A Type B Cable structure Twisted pair of wires, shielded One or more twisted pair of wires, overall shield Wire cross section (nominal) 0,8 mm 2 (AWG 18) 0,32 mm 2 (AWG 22) Loop resistance (direct current) 44 Ω/km 112 Ω/km Surge resistance at kh 100 Ω ±20 % 100 Ω ±30 % Wave attenuation at 39 khz 3 db/km 5 db/km Capacitive imbalance 2 nf/km 2 nf/km Group delay distortion 7.9 khz khz 1,7 µs * Degree of cover of the shield 90 % * Maximum network expansion for non-intrinsically-safe applications Maximum network expansion for intrinsically safe applications 1900 m 1200 m 1000 m * ABB 17

18 Annex B: Introduction to intrinsic safety The fieldbus systems in hazardous areas require the use of the increased safety (EExe) and intrinsic safety (EExi) protection types. The increased safety (EExe) protection type is used when powering fieldbuses. All devices are fitted with permissible terminals for this. Use of the intrinsic safety (EExi) protection type in the field allows the devices to be connected or exchanged while the system is in operation. When the EExi protection type is used, proof of intrinsic safety must be furnished. Two different models can be used for this: The FISCO model The Entity model The FISCO model The FISCO model was developed by the German Physical Technical Institute (PTB) and published in report PTB-W-53 Untersuchung zur Eigensicherheit bei Feldbus-Systemen (Investigation of intrinsic safety in fieldbus systems). FISCO stands for Fieldbus Intrinsically Safe COncept. This model is based on the following requirements: 1. To transmit electrical power and data, the bus system uses the Manchester Bus Powered physical layout in accordance with IEC This is the case both for FOUNDATION Fieldbus and for PROFIBUS PA. 2. Only one active source is allowed on a single bus segment (the Power Repeater/the Linking Device/ the Fieldbus Barrier). All other bus stations act as passive current sinks. 3. The basic current consumption of a bus station is at least 10 ma. 4. For each bus station (Ui, Ii, Pi), the following must be guaranteed: Ui Uo for the Linking Device/the Power Repeater/the Fieldbus Barrier Ii Io for the Linking Device/the Power Repeater/the Fieldbus Barrier Pi Po for the Linking Device/the Power Repeater/the Fieldbus Barrier 5. Each bus station (Ci, Li) must meet the following condition: Ci 5 nf Li 10 μh 6. The permissible line length for EEx ia IIC applications is 1000 m. 7. The permissible spur length for explosion protection applications is 60 m per spur line. The definition of the spur must be observed here. 8. The transmission line used must conform to the following cable parameters: Resistance per unit length: 15 Ω/km < R < 150 Ω/km Inductance per unit length: 0.4 mh/km L 1 mh/km Capacitance per unit length: 45 nf/km C 200 nf/km (including the shield) Taking the shield into account, the capacitance per unit length is calculated as follows: C = C conductor/conductor x C conductor/shield if the bus line is isolated or C = C conductor/conductor + C conductor/ shield if the shield is connected to a pole of the Linking Device/Power Link. 9. The bus segment must be terminated at both ends of the line with a bus terminator. The fieldbus terminator must adhere to the following limits: 90 Ω R 100 Ω 0 μf C 2.2 μf 18 ABB

19 The Entity model The Entity model is based on the observation that the cable represents a concentrated inductance and capacitance. This has the result that, compared to the FISCO model, less electrical energy can be transmitted into the hazardous area. Typical values here are 10.6 V and 70 ma. Result Fewer stations can be operated on a fieldbus segment The line lengths that can be achieved are smaller than in the case of the FISCO model Points 1 to 9 listed in the section The FISCO model also apply to the Entity model, with the exception of point 5. According to the Entity model, the internal inductance of a field device must be 20 μh and the internal capacitance must be 5 nf. The prerequisite for being able to furnish evidence of intrinsic safety in accordance with the FISCO model is that the source providing the power supply here the Linking Device, Power Repeater, or Fieldbus Barrier and all fieldbus stations are certified in accordance with the FISCO model. In addition, the cable must meet the requirements of the FISCO model. In order to prove intrinsic safety in accordance with the Entity model, in addition to comparing the voltage, current, and power, it is also necessary to establish that the inductances and capacitances connected to the Fieldbus Barrier do not exceed the maximum permissible values Lo and Co. In general: Lo Lcable + _Li Co Ccable + _Ci ABB 19

20 The latest information about ABB can be found on the Internet at abb Automation Technologies Mannheim, Germany Phone: +49 (0) Fax: +49 (0) Automation Technologies Västerås, Sweden Phone: +46 (0) Fax: +46 (0) Automation Technologies Wickliffe, Ohio, USA Phone: Fax: BDD EN Copyright 2006 ABB. All rights reserved. The content is subject to change without prior notice. Pictures, diagrams, and other graphics in this document are simply provided for illustration and do not represent any product configurations or product functions. The user documentation supplied with the product is the sole source for descriptions of product functionality. Industrial IT, Aspect Objects, and all product names mentioned above in the form XXXXXX IT are registered or requested trademarks of ABB. All rights to trademarks reside with their respective owners.

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field

More information

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes

warning indication issued about 2 weeks before the battery charge becomes critical Real-time clock - with battery back-up Yes System Freelance 800F AC 700F Module Description Data Sheet Central Processing Unit PM 783F Detailed data of the CPU (PM 783F) CPU Processor Program memory (Battery backed up) Internal memory Typical cycle

More information

The High Power Trunk Alternative to FISCO and FNICO

The High Power Trunk Alternative to FISCO and FNICO The High Power Trunk Alternative to FISCO and FNICO Bernd Schuessler, Business Development Manager Pepperl+Fuchs Twinsburg, OH 330-486-0002 www.fieldconnex.info End users throughout the Fieldbus world

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

Technical Information Fieldgate SFG500

Technical Information Fieldgate SFG500 TI00029S/04/EN/10.16 71324508 Products Solutions Services Technical Information Fieldgate SFG500 Smart Ethernet/PROFIBUS gateway Parallel access to PROFIBUS networks Monitoring of PROFIBUS and HART device

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

S900 Remote I/O System Intrinsic safety in the field ABB

S900 Remote I/O System Intrinsic safety in the field ABB S900 Remote I/O System Intrinsic safety in the field ABB 2 S900 REMOTE I/O SYSTEM INTRINSIC SAFETY IN THE FIELD The S900 Remote I/O System 01 Example of Field housing FH660S in stainless steel with complete

More information

System 800xA The Power of Integration. 800xA Device Management and Fieldbus Overview

System 800xA The Power of Integration. 800xA Device Management and Fieldbus Overview System 800xA The Power of Integration 800xA Device Management and Fieldbus Overview 2 800xA Device Management ABB System 800xA Introduction In their quest to lower lifecycle costs while improving productivity,

More information

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description Block device couplers Data sheet 3177_en_A 1 Description PHOENX CONTACT 2015-01-20 2 Features The and block couplers provide an interface between the fieldbus trunk cable and field devices on Foundation

More information

PSI-MOS-PROFIB/FO 850 T

PSI-MOS-PROFIB/FO 850 T Extract from the online catalog PSI-MOS-PROFIB/FO 850 T Order No.: 2708261 FO converter with integrated optical diagnosis, alarm contact, for PROFIBUS up to 12 MBit/s, T-coupler with two FO interfaces

More information

Control IT AC 800C Controller

Control IT AC 800C Controller Control IT AC 00C Controller the compact and cost-effective process controller Industrial IT Solutions from ABB AC 00C is a small, cost-effective controller belonging to the AC 00 family. It is configured

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

PSI-MOS-RS422/FO 850 T

PSI-MOS-RS422/FO 850 T Extract from the online catalog PSI-MOS-RS422/FO 850 T Order No.: 2708397 FO converter with integrated optical diagnosis, alarm contact, for RS-422/RS-485 4-wire/ INTERBUS to 2 Mbit/s, T-coupler with two

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

PHOENIX CONTACT - 07/2006

PHOENIX CONTACT - 07/2006 Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,

More information

PHOENIX CONTACT - 02/2008

PHOENIX CONTACT - 02/2008 Ex-i solenoid driver for Group IIC gases, loop-powered, pluggable INTERFACE Data Sheet 103211_00_en PHOENIX CONTACT - 02/2008 1 Description The solenoid driver PI-EX-SD-21-25 links a signaling device installed

More information

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.:

TRIO-PS/1AC/24DC/20. Extract from the online catalog. Order No.: Extract from the online catalog TRIO-PS/1AC/24DC/20 Order No.: 2866381 DIN rail power supply unit, primary-switched mode, 1-phase, output: 24 V DC / 20 A Commercial data EAN 4046356046664 Pack 1 pcs. Customs

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Technical Description

Technical Description Technical Description I/O Application-Guide CI920S/CI920B replaced by /CI920AB Products Concerned Installed Products Item Article number Item Description CI920B V1.5.9 3BDS014112 Communication Interface

More information

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail

Assembly. Front view. LED yellow: Relay output. LED red: LB/SC Power Rail Switch Amplifier Features Assembly -channel isolated barrier 4 V DC supply (Power Rail) Dry contact or NAMUR inputs Relay contact output Line fault detection (LFD) Reversible mode of operation Up to SIL

More information

AC 800M for Compact Product Suite Outline of all modules

AC 800M for Compact Product Suite Outline of all modules DATA SHEET AC 800M for Compact Product Suite Outline of all AC 800M is a family of rail-mounted, consisting of CPU:s, communication, power supply and various accessories. There are several CPU to choose

More information

QUINT-PS/ 1AC/24DC/ 5

QUINT-PS/ 1AC/24DC/ 5 Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)

More information

10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs

10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs 10 Mb/s Single Twisted Pair Ethernet Process Industry Requirements Steffen Graber Pepperl+Fuchs IEEE802.3 10 Mb/s Single Twisted Pair Ethernet Study Group 9/8/2016 1 Overview Introduction Current bus Infrastructure

More information

STEP-PS/1AC/24DC/1.75

STEP-PS/1AC/24DC/1.75 Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new

More information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information

4 â Active barrier RN221N with optional HART diagnosis. Technical Information Technical Information Active barrier with optional HART diagnosis Active barrier with power supply for safe separation of 4 to 20 ma current circuits Application Galvanic isolation of 4 to 20 ma current

More information

QUINT-PS AC/24DC/10

QUINT-PS AC/24DC/10 Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

PHOENIX CONTACT - 05/2007

PHOENIX CONTACT - 05/2007 Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007

More information

New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs. Andreas Agostin Pepperl+Fuchs

New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs. Andreas Agostin Pepperl+Fuchs New FOUNDATION Fieldbus Interface Techniques Increased Availability and Reduced Costs Andreas Agostin Pepperl+Fuchs Abstract InfraServ Hoechst and Aventis Pharma of Germany performed a comparison study

More information

AC 800M Controllers Outline of all modules

AC 800M Controllers Outline of all modules DATA SHEET AC 800M Controllers Outline of all AC 800M is a family of rail-mounted, consisting of CPU:s, communication, power supply and various accessories. There are several CPU to choose from, ranging

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Type 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i solenoid valves, piezo and booster-valves Intrinsically safe Ex ia IIC outputs Additional input for Plant-STOP available (acc. to

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area.

PHOENIX CONTACT - 06/2007. DANGER OF EXPLOSION! Remove an item only when it is not connected to power or if it is located in the non-explosive area. Primary switched power supply, 3-phase, output current: 40 A INTERFACE Data Sheet 102782_01_en PHOENIX CONTACT - 06/2007 Description TRIO POWER is the rail mountable 24 V power supply unit with basic functions.

More information

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description

ILBPB24DO32. Inline Block IO Module for PROFIBUS With 32 Digital Outputs. AUTOMATIONWORX Data Sheet 6889_en_04. Description Inline Block IO Module for PROFIBUS With 32 Digital Outputs AUTOMATIONWORX Data Sheet 6889_en_04 Description PHOENIX CONTACT - 03/2007 & & ' ) The ILB PB 24 DO32 module is designed for use within a PROFIBUS

More information

H 250 with PROFIBUS-PA signal converter ESK3-PA

H 250 with PROFIBUS-PA signal converter ESK3-PA KROHNE 12/2000 7.02117.21.00 GR Supplement to Installation and Operating Instructions Variable area flowmeter H 250 with PROFIBUS-PA signal converter ESK3-PA Version: 1.02/00-06-29 Suitable for software

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

TEPI11 P/I signal converter

TEPI11 P/I signal converter Contents Data Sheet 10/18-0.15-EN Rev. A TEPI11 P/I signal converter Air pressure in current DMS sensor for gauge pressure Compact design Small dimensions, low weight Can be installed in any orientation

More information

PA ROUTERS. The following criteria can be applied when choosing the network transition:

PA ROUTERS. The following criteria can be applied when choosing the network transition: PA ROUTERS To create a smooth network transition between PROFIBUS DP and PROFIBUS PA, the SIMATIC product range offers two versions: the DP/PA coupler and the PA link. The following criteria can be applied

More information

ASI QUINT /2.4 EFD

ASI QUINT /2.4 EFD Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678

More information

Freelance 800F packed with new features! Coming soon

Freelance 800F packed with new features! Coming soon Freelance 800F packed with new features! Coming soon abb Two very special highlights: The new AC 700F controller for extended scalability towards PLCs Different solutions are used in automation depending

More information

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-RIO16-PF. Features. Assembly. Function. Connection USIO/UPIO 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Universal Safety IO System board for Honeywell Universal Process IO For 6-channel cards USIO and UPIO For 6 modules Recommended modules: HiC8R (DI), HiC85R

More information

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni)

Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Data sheet 302040_en MTP300i-SIL-K Loop-powered Transmitter for Thermocouple Type K (NiCr-Ni) Properties 2-wire temperature transmitter for DIN rails Galvanic isolated TC-input with cold-junction compensation

More information

Benefits derived from the FF specification FF-831

Benefits derived from the FF specification FF-831 Foundation Fieldbus End Users Council Australia Inc. 9 Corcoran St Duncraig, WA 6023 P.O. Box Z5546 Perth, WA 6831 Benefits derived from the FF specification FF-831 Why we need it, and why it improves

More information

Easy Analog RNB130. Technical Information. Primary switched-mode power supply

Easy Analog RNB130. Technical Information. Primary switched-mode power supply Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power

More information

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital

Design Benefits. Teo Puay Yong Pepperl+Fuchs. On Behalf of FF Marketing Society. The Future is Digital. 1 The Future is Digital Design Benefits The Future is Digital Teo Puay Yong Pepperl+Fuchs On Behalf of FF Marketing Society 1 The Future is Digital Design Benefits from Applying Foundation Fieldbus Bus structure and Wiring Loop

More information

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

PHOENIX CONTACT - 01/2008

PHOENIX CONTACT - 01/2008 Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex

More information

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications.

Safety Barriers. CEAG safety barriers can be used for all kinds of instrumentation applications. Safety Barriers Description Safety barriers limit the energy fed to an intrinsically safe circuit so that neither sparks nor thermal effects (hot surfaces) can cause an explosion. CEAG safety barriers

More information

PSI-MOS-PROFIB/FO 850 T

PSI-MOS-PROFIB/FO 850 T Extract from the online catalog PSI-MOS-PROFIB/FO 850 T Order No.: 2708261 FO converter with integrated optical diagnosis, alarm contact, for PROFIBUS up to 12 MBit/s, T-coupler with two FO interfaces

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div. Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function

More information

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX

PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX PROCESS AUTOMATION YOUR PARTNER FOR INDUSTRY-SPECIFIC INSTALLATION SOLUTIONS FIELD JUNCTION BOX OUR COMPONENTS... CONFIGURABLE TO YOUR NEEDS No application is like the others; every application always

More information

Redundancy Module QUINT-DIODE/40

Redundancy Module QUINT-DIODE/40 Redundancy Module QUT DIODE provides: 00% decoupling of power supplies connected in parallel Can be installed in potentially explosive areas Load currents up to 60 A supported Easy assembly by snapping

More information

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:

QUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Tutorial: Characteristics & Requirements of Physical Networks in the Process Industry

Tutorial: Characteristics & Requirements of Physical Networks in the Process Industry Tutorial: Characteristics & Requirements of Physical Networks in the Process Industry IEEE802.3cg 10 Mb/s Single Twisted Pair Ethernet Task Force Brian Franchuk Martin Zielinski Introduction 2 Pertinent

More information

MINI-PS AC/10-15DC/8

MINI-PS AC/10-15DC/8 Primary-Switched Power Supply, Narrow Design Data Sheet 08/2004 MINI POWER provides: An extra narrow design, with widths of 22.5 mm, 45 mm, and 67.5 mm (0.886, 1.772, and 2.657 in.) Global use due to a

More information

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 103349_en_00 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic

More information

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail

Assembly. Front view. LED yellow/red: Status output Ι/ Fault signal Function. Switch Power Rail Switch Amplifier KCD-SR-Ex.LB Features Assembly -channel isolated barrier V DC supply (Power Rail) Dry contact or NAMUR inputs Usable as signal splitter ( input and outputs) Relay contact output Fault

More information

Interface and Supply module. IPC 3x0i / PSC 3x0i

Interface and Supply module. IPC 3x0i / PSC 3x0i Interface and Supply module IPC 3x0i / PSC 3x0i Installation Guide Version 10 IBS BatchControl GmbH Im Sträßchen 2 4 Tel.: +49 2241 9199801 53925 Kall Fax.: +49 2241 9199871 Germany www.ibs-batchcontrol.com

More information

AC 800M Controller Outline of all modules

AC 800M Controller Outline of all modules DATA SHEET AC 800M Controller Outline of all AC 800M is a family of rail-mounted, consisting of CPU:s, communication, power supply and various accessories. There are several CPU to choose from, ranging

More information

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems

PSM-ME-RS232/TTY-P Interface converter for RS-232 to TTY transmission systems Interface converter for RS- to transmission systems. Short Description The rail-mountable and compact interface converters have been designed especially for industrial use in the switch cabinet or switch

More information

Operating Instructions

Operating Instructions Operating Instructions t i SPAN NOT USED - - 4...20mA DISPLAY t i SPAN END POINT DISPLAY Ð - 4...20mA p Safety information, Note Ex area Safety information Please read this manual carefully, and also take

More information

PROFIBUS Course Document Certified PROFIBUS Installer Course CPI Version 1.1 June 2011 Order No: PROFIBUS Learning Outcomes, Order No: 4.

PROFIBUS Course Document Certified PROFIBUS Installer Course CPI Version 1.1 June 2011 Order No: PROFIBUS Learning Outcomes, Order No: 4. PROFIBUS Course Document Certified PROFIBUS Installer Course CPI Version 1.1 June 2011 Order No: 4.722 PROFIBUS Learning Outcomes, Order No: 4.722 Course Title: Course Code: Course Duration: Grading Type:

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

CPU module for zone 2 Series 9442/35

CPU module for zone 2 Series 9442/35 > Supports PROFIBUS DP, PROFINET, Modbus TCP and Ethernet/IP; incl. HART transmission > RS-485 (max. 12 Mbps) and Ethernet (max. 100 Mbps) interfaces > Extensive diagnostics based on NE 107 > Support of

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

PROFIBUS-PA PROFIBUS-DP. Field Communication PROFIBUS-DP/PA: Guidelines for planning and commissioning

PROFIBUS-PA PROFIBUS-DP. Field Communication PROFIBUS-DP/PA: Guidelines for planning and commissioning PROFIBUS-PA PROFIBUS-DP Field Communication PROFIBUS-DP/PA: Guidelines for planning and commissioning Profibus-DP/PA Overview able of Contents able of Contents Notes on Safety................. 3 1 Introduction......................

More information

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.:

MINI-DC-UPS/12DC/4. Extract from the online catalog. Order No.: Extract from the online catalog MINI-DC-UPS/12DC/4 Order No.: 2866598 Uninterruptible power supply with integrated power supply unit, 4 A, in combination with MINI-BAT/12/DC 1.6 Ah or 2.6 Ah Commercial

More information

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.:

MINI MCR-SL-UI-2I-NC. Extract from the online catalog. Order No.: Extract from the online catalog MINI MCR-SL-UI-2I-NC Order No.: 2864176 4-way signal duplicator for electrical isolation and duplication of analog signals with screw connection, standard configuration

More information

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications.

WG 20. The WG 20 achieves an extraordinarily. accuracy for hazardous-area. applications. Modular Housings for Hazardous Areas For transmission of 0(4)... 20-mA signals from hazardous areas or supply of intrinsically safe 2-wire transmitters. The Task The power supply/isolator is used to supply

More information

Analog output 520AOD01 Data sheet

Analog output 520AOD01 Data sheet RTU520 product line Analog output 520AOD01 Data sheet ERR RTU I/O bus Microcontroller RAM Flash Output register DC DC D D A A Adjustment Output range O1 O2 Adjustment Output range IOC UE Figure 1: Block

More information

TRIO-DIODE/12-24DC/2X10/1X20

TRIO-DIODE/12-24DC/2X10/1X20 Redundancy module INTERFACE Data sheet 104278_en_00 1 Description PHOENIX CONTACT 20100423 Features TRIO DIODE is the DINrail mountable redundancy module from the TRIO POWER product range. Using the redundancy

More information

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description

MINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase.

STEP-PS/1AC/24DC/2.5. Extract from the online catalog. Order No.: DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase. Extract from the online catalog STEP-PS/1AC/24DC/2.5 Order No.: 2868651 DIN rail power supply of 24 V DC/2.5 A, primary switched, single phase. Commercial data EAN 4046356163224 Pack 1 pcs. Customs tariff

More information

PROFIBUS and Integrated Safety architectures in Ex areas

PROFIBUS and Integrated Safety architectures in Ex areas PROFIBUS and Integrated Safety architectures in Ex areas Since 1989, PROFIBUS has developed into a worldwide leading fieldbus system used in machine and process plant automation. The main reason why PROFIBUS

More information

Intrinsically Safe Barriers

Intrinsically Safe Barriers Intrinsically Safe Barriers Description Page No. Safety Barriers 464-472 Din Rail Isolated Barriers 473-488 477 Intrinsically Safe Barriers Product Overview We have simplified intrinsic safety! Cooper

More information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information

Separating and protective. Separating and protective instruments. VEGATRENN 149AEx Separator type KFDO Barrier type Product Information Separating and protective instruments Separating and protective instruments VEGATRENN 149AEx Separator type KFDO Barrier type 9001 Product Information Content Content 1 Product description..........................................................................

More information

FF Physical Layer Components

FF Physical Layer Components FF Physical Layer Components Best Practices Binoy Kamath AGM Project Pursuit Pepperl+Fuchs India Pvt. LTd.,Bangalore Agenda Introduction to FF and FF Physical Layer FF Physical Layer Components FF Wiring

More information

QUINT-BUFFER/24DC/24DC/40

QUINT-BUFFER/24DC/24DC/40 Buffer module Data sheet 105496_en_01 PHOENIX CONTACT 2013-11-01 1 Description The QUINT BUFFER buffer module combines the electronic switchover unit and power storage in the same housing. The buffer module

More information

MACX MCR-EX-SD LP(-SP)

MACX MCR-EX-SD LP(-SP) Intrinsically safe solenoid driver for Group IIC gases, loop-powered, current limit 48 ma INTERFACE Data sheet 103468_en_01 PHOENIX CONTACT - 08/2008 1 Description The solenoid driver MACX MCR-EX-SD-24-48-LP(-SP)

More information

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this

Your process requires the utmost attention Our new ACT20C signal conditioners support you in achieving this Overview Signal converters Your process requires the utmost attention Our new signal conditioners support you in achieving this Many process parameters in your system are handled by your control system,

More information

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.

PHOENIX CONTACT - 05/2008. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area. Primary switched power supply, 1-phase, output current: 5 A ITERFACE Data Sheet 102777_en_03 1 Description PHOEIX COTACT - 05/2008 Features TRIO POWER is the DI-rail-mountable power supply unit with basic

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

Distributed Intrinsically Safe Fieldbus Applications

Distributed Intrinsically Safe Fieldbus Applications Application Note FB01-1 - Distributed Intrinsically Safe Fieldbus Applications Emerson Process Management DeltaV DCS System Pepperl+Fuchs June 2003 Application Note FB01-2 - c Pepperl+Fuchs Inc. All rights

More information

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.:

FL SWITCH SFN 5TX. Extract from the online catalog. Order No.: Extract from the online catalog FL SWITCH SFN 5TX Order No.: 2891152 Ethernet switch, 5 TP RJ45 ports, automatic detection of data transmission rate of 10 or 100 mbps (RJ45), autocrossing function Commercial

More information

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:

QUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.: Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged

More information

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F

4 Remote I/O. Digital Output Module 8-Channel Version Series 9475/ from Rev. F 4 Remote I/O Digital Output Module 8-Channel Version 8 channels for Ex i / I.S. solenoid valves, piezo and booster valves Intrinsically safe outputs Ex ia IIC Additional input for "Outputs OFF" available

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information