1 C5C Cross-Connect System I N S T A L L A T I O N I N S T R U C T I O N High-Density Connection Blocks 1.0 General Product Information The C5C cross-connect system is comprised of a high-density connection block, a mounting bracket, and accessory products to accommodate specific needs. The block is designed for use in indoor or outdoor applications requiring a high-density, smallfootprint cross-connection system and is available with normally open or normally closed contacts.* The C5C system accommodates solid copper conductors, AWG. * Blocks with red markings have normally open contacts. In/Out are not connected until a protector is installed; therefore, protectors are required. The model number for normally open blocks is C5C-MZO-10-R-G-G-RVA. Blocks with black markings have normally closed contacts. In/Out are connected inside the block regardless of the presence or absence of a protector. The model number for normally closed blocks is C5C-MXO-10-W-G-G-US00RVA. For protected units, both the communication line protector model C5C-ACC-PBETXX and the power pair protector model C5C-ACC-PWER-C-X-XXXX-A feature a voltage breakdown rating of VDC. 2.0 Kit Components Kit components can be ordered separately. (Figure 1) Blocks Numbered pair markers** Disposable C5C installation tool **Representative types of mounting bracket and numbered pair markers are shown in these instructions. Other types available. 3.0 Cautions and Warnings DANGER: To reduce the risk of electrical shock, do not install product during lightning storms, or contact exposed wires or termination points. Removing an installed protector from a normally closed (black marked) block completes the circuit. Removing an installed protector from a normally open (red marked) block opens the circuit. C5C protected units require a locally approved ground connection to the mounting bracket. The C5C cross-connect system is UL listed for indoor/outdoor use when installed in a suitably approved UL listed enclosure including units mounted on or inside a building. To maintain a UL listing, C5C protectors require a 26 AWG fuse-link, installed per locally approved practices. A fuse link should not be confused with circuit protection. Use/follow all applicable safety equipment/practices for installation and operation, including company, local, NEC and ANSI/NFPA Installation Instructions 4.1 Mounting Frame Installation 1. Mount the frame to a vertical surface by inserting screws through the holes in the mounting bracket. Tighten securely. (Figure 2) Note: Some frames have key hole slots. Install four screws in the vertical surface. Slide the frame over the screwheads and tighten them securely. 1 2
2 Grounded applications typically require a #6 AWG solid copper bond wire installed to the mounting bracket per locally approved practices, tightened to a torque value of 40 inch pounds. Use the bond stud on the bracket, if supplied, for attaching the bond wire. 4.2 Block Installation and Wire Termination Note: The C.O./feeder ports are at the top of the block, and the distribution/jumper ports are at the bottom. 1. Starting at the bottom of the bracket, snap an empty 10-pair C5C block into place on the slots on the bracket. (Figure 3) 2. Route a C.O./feeder wire pair through the opening in the back of the bracket. 3. Feed the wire pair through the wire routing loop on the back of the block. (Figure 4 inset) 4. Feed the wire pair through the wire routing loop on top of the block, and to the desired set of wire ports (numbered on the front of the block). (Figure 4) back of block wire routing loop 3 wire routing loops, top of block 4 5. With the tip wire on the left and the ring wire on the right, align the wires with the ports and let them hang down by at least 2 inches in front of the ports. (Figure 5) NOTE: Do not pull the wires down firmly or trap them in the lower port slots Hold the C5C installation tool with the longer forks up, then push the wire into the block ports as shown, completing the termination. The C.O./feeder ports are at the top of the block, and the distribution/jumper ports are at the bottom. (Figure 6) CAUTION: Be careful to avoid damaging the insulation of other nearby wires when using the tool to push the selected wire into the block port. Note: Remove the severed wire ends to prevent them from interfering in subsequent connections. 6
3 7. Route the distribution wire pair through the opening in the mounting bracket, and through the wire routing loop on the side of the block closest to the desired port. (Figure 7) wire routing loop, side of block 7 8. With the tip wire on the left and the ring wire on the right, align the wires with the ports and let them extend beyond the ports by at least 2 inches. Holding the wire pair in front of the tip/ring ports, use the C5C installation tool (forks down) to push the wire pair into the corresponding lower ports, completing the termination. (Figure 8) CAUTION: Be careful to avoid damaging the insulation of other nearby wires when using the tool to push the selected wire into the block port. Note: Remove the severed wire ends to prevent them from interfering in subsequent connections When the first block is fully populated with feeder pairs, install a second block on top of the first one. Repeat until the mounting bracket is fully populated with ten 10-pair blocks. (Figure 9) Wire Pair Removal The C5C installation tool includes a small hook that pulls out from the tool handle. Use this hook to pick a wire to remove from its connection, and simply jerk it firmly to disconnect it from the block. (Figure 10) Note: Make sure any other wires are clear of the wire pair being removed. 10
4 5.0 Accessory Component Installation C5C protectors are offered in two styles: a communications line protector (model number C5C-ACC-PBETXX) and a power pair protector (model number C5C-ACC-PWER-C-X-XXXX-A). The communications line protector is used to protect a single pair telephone connection. The power pair protector is used to protect one independent Telco wireline power input, up to 100VA, distributed between 1 to 3 independent load pairs using C5C 10 pair blocks. Both protectors are gel-sealed against harsh OSP environments. Gas discharge tube technology is utilized by both styles to insure high fault-current management and both are equipped with thermal fail-safe mechanisms to insure safe failure mode during extended AC fault operation. Both offer 350+/- 20VDC rating and impulse spark-over at 100V/microsecond < 750V. 5.1 Installing Circuit Protectors Important: C5C protected units require a locally approved ground to the mounting bracket as described on page 2. 1 Power Pair powering 3 Equipment Pairs Power Pair Protector C5C Blocks Power Load Out Power In Power Load Out Power Load Out Power Pair Protector Communications Line Protectors available in red and black To install circuit protection, follow these steps: Note: Do not install ground bar until all incoming wires are terminated Hold the silver metal ground bar flat on top of the block and push it in until it snaps into place. (Figures 11 and 11a) 11a Install a circuit protector by pushing it into the slot between the feeder and distribution ports, and over the prong of the ground bar above the ports. Push it in until it snaps into place. (Figure 12) Installation of a power pair protector is similar: push the two legs into two slots between the top and bottom ports of the pairs to be protected, and over the prong of the ground bar above the ports. (Figure 13) 13
5 5.2 Removing Circuit Protectors The C5C installation tool includes a small hook that pulls out from the tool handle. Place the hook in the small hole at the end of the circuit protector, and pull until the circuit protector releases from the block. (Figure 14) Testing Wire Pairs and Circuit Protection Three test cords are available for the C5Ccross-connect system: A dual test cord with Monitoring and Interrupt test heads, plus a talk pair bracket that can be mounted inside a cabinet (Figure 15) A dual test cord with Monitoring and Interrupt heads only (Figure 16) A Universal test cord with Monitoring, Interrupt, and Protector test heads (Figure 17) CAUTION: Use a clean cloth to wipe off the test head mating surfaces before each use. Dual test cord with bracket Test or Monitor an Unprotected Circuit Without Interruption 1. To monitor an unprotected uninterrupted circuit, push the black test head labeled MON, with TE logo on top, into the desired port set so that it penetrates the slot between the top and bottom terminations pairs. Be sure that the plug is inserted until it is flush with the front of the C5C block. 2. Connect the test device to the ring terminals labeled MON lowercase t for (tip) and MON lowercase r for (ring) Test or Interrupt an Unprotected Circuit The red test head labeled INT will interrupt the circuit to allow top and bottom side isolation. The circuit can be tested from the connection point to the CO or from the connection point to the Field. 1. To interrupt the circuit for testing, push the red test head labeled INT, with TE logo on top, into the desired port set so that it penetrates the slot between the top and bottom terminations pairs. Be sure that the plug is inserted until it is flush with the front of the C5C block. 2. To test the top side Tip and Ring, connect the test device to the ring terminals labeled INT capital T for (tip) and INT capital R for (ring). 3. To test the bottom side tip and ring, connect the test device to the ring terminals labeled INT lowercase t (tip), INT lowercase r for (ring). Dual test cord 16
6 5.3.3 Test or Monitor a Protected Circuit Without Interruption (Universal Test Cord Only) Universal test cord 1. To monitor a protected uninterrupted circuit, slide the black open-profile test head with test prongs on the bottom over the installed circuit protector and push until the test head snaps on to the installed protector. Be sure that the two test prongs are inserted in the bottom tip and ring ports. 2. Connect the test device to the ring terminals labeled MON PT for tip, and MON PR for ring Connect or Replace Dual-Head Test Cord on Test Cord Bracket If you purchase a dual-head test cord and bracket separately and need to install them, or if you need to replace a test cord previously installed on a test cord bracket, install the ring terminals on the test cord bracket as shown in the diagram at right. Connect INT R to terminal R T Connect INT T to terminal T R t Connect INT r and MON r to terminal r r Connect INT t and MON t to terminal t Connect or Replace Universal Test Cord on Test Cord Bracket Connect INT R to terminal R R Connect INT r, MON P r, and MON r to terminal r If you purchase a universal (three-head) test cord and bracket separately and need to install them, or if you need to replace a test cord previously installed on a test cord bracket, install the ring terminals on the test cord bracket as shown in the diagram at right. T Connect INT T to terminal T t r Connect INT t, MON P t, and MON t to terminal t
7 5.4 Installing Pair Markers Small and large numbered pair markers can be used to identify the wire pairs. To install the small numbered pair markers, break off each one as needed from the carrier strip and add into the block. Insert markers in the openings at the ends of the block as shown. (Figure 18a) To install the larger pair markers, locate the two guide pins on the pair markers. Align the pair markers so that the guide pins are centered in the slot between the mounting bracket and the edge of the plastic C5C block. Push in on the front and the sides at the same time to snap the pair marker into place. (Figure 18b) To remove the large pair marker, pull the bottom of the marker out away from the mounting bracket. 18a 18b 5.5 Installing Circuit Breaker Tabs Black and red circuit breaker tabs allow a circuit (in normally closed (black marked) blocks) to be temporarily disconnected. To install a circuit breaker tab, simply push it into the slot between the feeder and distribution pairs of the desired circuit. When the breaker tab is removed, the circuit is restored. (Figure 19) 19
8 5.6 Installing Special Circuit Markers Red special circuit markers are used to denote special circuits per company regulations. To install a special circuit marker, simply push it into the slot between the feeder and distribution pairs of the special circuit. (Figure 20) 20 Technical Assistance Center (TAC) Tel.: TAC.Americas@commscope.com C5C, CommScope logo, and CommScope are trademarks. The information given herein, including drawings, illustrations and schematics which are intended for illustration purposes only, is believed to be reliable. However, CommScope makes no warranties as to its accuracy or completeness and disclaims any liability in connection with its use. Commscope obligations shall only be as set forth in CommScope Standard Terms and Conditions of Sale for this product and in no case will CommScope be liable for any incidental, indirect or consequential damages arising out of the sale, resale, use or misuse of the product. Users of CommScope products should make their own evaluation to determine the suitability of each such product for the specific application. 2008, 2009, 2016 CommScope Inc. All Rights Reserved PML C605.03/09
Replacing the Power Supply
APPENDIX B This appendix includes information on how to replace the power supply for the Cisco AS550XM universal gateway and contains the following sections: Safety Recommendations, page B-1 Required Tools
More informationPower Supply Installation
Power Supply Module Overview, on page Installation Guidelines, on page 4 Installing or Replacing an AC Power Supply, on page 6 Installing a DC Power Supply, on page 7 Finding the Power Supply Module Serial
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationPower Supply and Fan Module Installation
3 CHAPTER This chapter describes how to remove and install a new or replacement power supply or fan module in a Catalyst 3750-E or Catalyst 3560-E switch. See these sections: Installation Overview, page
More information3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series
3M Indoor Building Entrance Terminal (IBET) 4790V and 4790VL Series with 3M Quick Connect System (QCS) 2811 Dry Flame-Retardant Block and RJ-11 Test Ports Instructions Underwriters Laboratories (UL 348X)
More informationMPP200 User s Manual
2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.
More informationIndoor Protected Entrance Terminal 4588 Series
Indoor Protected Entrance Terminal 4588 Series Instructions Underwriters Laboratories (UL) Listed September 2003 78-8135-1209-8-A 1.0 General The 3M Indoor Protected Entrance Terminal (PET) 4588 Series
More informationUSP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10
UniStream HMI Panel Installation Guide USP-070-B10, USP-070-B08 USP-104-B10, USP-104-M10 USP-156-B10 Unitronics UniStream platform comprises control devices that provide robust, flexible solutions for
More information3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs)
3M Add-On Terminals 4220P (100, 200, 300 & 400 pairs) Instructions August 2011 3 78-8130-2330-1-C 1.0 General 1.1 The 3M Add-On Terminals 4220P-100, 4220P-200, 4220P-300 and 4220P-400 are designed to expand
More informationInstallation of the POTS splitter card requires the following steps: Determining the cables you need. Installing the POTS splitter chassis
5910 High Density Lifeline POTS Splitter Installation Instructions Document Number 5910-A2-GZ40-00 May 2005 About the 5910 POTS Splitter The 5910 is a double-density POTS splitter that separates the (Digital
More informationInstallation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V C30B and V T40B.
Vision OPLC Installation Guide V290 (Color) This guide provides basic information for Unitronics LCD color touchscreen models V290-19-C30B and V290-19-T40B. General Description Vision OPLCs are programmable
More information3M Indoor Protected Building Entrance Terminal 4588V-QCS Series
3M Indoor Protected Building Entrance Terminal 4588V-QCS Series with 3M Quick Connect System 2811 Dry Flame Retardant Block Instructions Underwriters Laboratories (UL 348X) Listed April 2010 3 78-0013-1813-4-A
More information3M Indoor Protected Building Entrance Terminal 4788V-QCS Series
The Network of Networks. 3M Indoor Protected Building Entrance Terminal 4788V-QCS Series with 3M Quick Connect System (QCS) 2811 Dry Flame Retardant Block for Field-Terminated Building Cables Instructions
More informationThis guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens).
Vision OPLC Installation Guide Models 230/260/280/290 (Non-color Screens) This guide provides basic information for Unitronics Models 230/260/280/290 (Non-color Screens). General Description Vision OPLCs
More informationOCM5 Splitters and Pass-Through Modules for CSX-3 Cabinets
OCM5 Splitters and Pass-Through Modules for CSX-3 Cabinets I N S T A L L A T I O N I N S T R U C T I O N 1.0 General Product Information Splitters for the CSX-3 cabinets are purchased and installed as
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808R, UID-0808T, UID-1600,UID-0016R, UID-0016T Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UID-0808THS Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationFLAT FLEXIBLE CABLE (FFC) CONNECTORS
FLAT FLEXIBLE CABLE (FFC) CONNECTORS TE Connectivity s (TE) family of FFC connectors includes a variety of high density cable-to-board and cable-to-cable connectors designed for automated assembly. The
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIA-0402N Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Wide Modules Installation Guide UID-W1616R, UID-W1616T Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide
More informationThe identified danger could cause physical and property damage.
Samba OPLC SM35-J-T20 Installation Guide The Unitronics SM35-J-T20 offers the following onboard I/Os: 12 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder Inputs 8 Transistor
More informationTHE CTB08D LIGHT CONTOLLER
THE CTB08D LIGHT CONTOLLER The CTB08D is a one of the components in the Hobbyist line of Light- O-Rama products. The CTB08D must be used in conjunction with the Light-O-Rama software package. This controller
More informationED-22 Analog Output Series Magnetic Encoder
SPECIFICATIONS Analog voltage output Low profile Standard industry package size Sleeve bearing The ED-22 series magnetic encoder can be used to replace a conventional potentiometer. This product offers
More informationModel 2460-KIT. Screw Terminal Connector Kit. Description / September 2014 *P * 1
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Model 2460-KIT Screw Terminal Connector Kit Description The Model 2460-KIT Screw Terminal Connector Kit
More informationOPLC Installation Guide
Samba OPLC SM35-J-R20/SM43-J-R20 SM70-J-R20 SM35-J-T20/SM43-J-T20 SM70-J-T20 OPLC Installation Guide 12 Digital Inputs, include 1 HSC/Shaft-encoder Input, 2 Analog inputs (only when the digital inputs
More information22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs
Vision PLC+HMI V130-33-T38/V130-J-T38 V350-35-T38/V350-J-T38 V430-J-T38 Installation Guide 22 Digital Inputs, including 2 Analog, 2 HSC/Shaft-encoder inputs 16 Transistor Outputs General Description All
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Modules Installation Guide UIS-04PTN Uni-I/O is a family of Input/Output modules that are compatible with the UniStream control platform. This guide provides basic installation information for
More information3M Indoor Protected Building Entrance Terminal (IBET) 4688V Series
3M Indoor Protected Building Entrance Terminal (IBET) 4688V Series Instructions Underwriters Laboratories (UL 348X) Listed February 2017 78-0013-6127-4-B 2 February 2017 78-0013-6127-4-B 1.0 General The
More informationEMS. Electrical Management System. Progressive Industries Incorporated Morrisville, North Carolina
Progressive Industries Warranty Progressive warrants its products are free from defects in materials and workmanship for a period of three years. This is in lieu of all other warranties, obligations, or
More information* * Agilent Power Distribution Unit (PDU) Installation Guide
Agilent Power Distribution Unit (PDU) Installation Guide For use with Agilent PDU kits and PDU installation kits for Agilent instrument racks June 2008 Edition 7 E0608 *5000-0039* 5000-0039 Notice The
More informationPICO PROTECTOR PG-25 & PK-25 Series
PICO PROTECTOR PG-25 & PK-25 Series Installation Instructions LISTED 95P5 SIGNAL CIRCUIT PROTECTOR Introduction The Siemon Company s Pico Protector Kits protect voice and data equipment from sneak current
More informationVision OPLC V TR6/V350-J-TR6
Vision OPLC V350-35-TR6/V350-J-TR6 Installation Guide The Unitronics V350-35-TR6/V350-J-TR6 offers the following onboard I/Os: 8 Digital Inputs, configurable via wiring to include 2 Analog (current/voltage)
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Vision OPLC V350-35-R34/V350-J-R34 Installation Guide The Unitronics V350-35-R34/V350-J-R34 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 3 HSC/Shaft-encoder
More informationUser s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)
User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationPSA200 User s Manual
2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.
More informationProgressive Industries, Inc. EMS Electrical Management System
Progressive Industries, Inc. EMS Electrical Management System Complete Installation Guide and Operating Instructions for: Model EMS-LCHW50 Rated at 240V/50A Manufactured by: Progressive Industries, Inc.
More informationOmnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual
Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-COM Modules Installation Guide UAC-01RS2,UAC-02RS2,UAC-02RSC Uni-COM is a family of communication modules that are compatible with the UniStream control platform. This guide provides basic installation
More informationINSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE
INSTALLATION AND USER GUIDE 2800MWB SINGLE LINE BASIC FEATURE TELEPHONE TeleMatrix Copyright 2005 COMPLIANCE AND SAFETY As specified by FCC regulation, we are required to inform you of specific governmental
More informationInstalling the Cisco SFS 3504 Server Switch
CHAPTER 3 This chapter describes how to mount your Cisco SFS 3504 Server Switch on a rack, boot the Cisco SFS 3504 Server Switch, and configure basic services. For advanced configuration information, see
More informationElectrical Management System (EMS) EMS-HW30C & EMS-HW50C
Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all
More informationPRINTER ACCESSORIES TECHNICAL DATASHEET UNIVERSAL REEL HOLDER
PRINTER ACCESSORIES TECHNICAL DATASHEET TTDS-260 issue 3, July 2015 UNIVERSAL REEL HOLDER The Universal reel holder is a free standing bench top, or wall mounted reel holder. Designed to dispense all TE
More informationMPP1700 User s Manual
2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide Copyright Information The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing
More information4888 and 4988 Outdoor Protected Entrance Terminals
4888 and 4988 Outdoor Protected Entrance Terminals Underwriters Laboratories (UL) Listed Instructions January 1997 34-7031-7272-5 Revision C Contents: 1.0 General... 1 2.0 Accessories... 2 3.0 Protector
More informationInstruction Manual. Electrical Management System (EMS) EMS-HW30C & EMS-HW50C
Instruction Manual Electrical Management System (EMS) EMS-HW30C & EMS-HW50C EMS-HW50C EMS-HW30C! CAUTION These instructions are intended to provide assistance with the installation of this product, and
More informationThis guide provides basic information for Unitronics controller model V T2.
Vision OPLC 12 pnp/npn Digital, including 2 Analog, 3 HSC/Shaftencoder Inputs, 12 Transistor Outputs This guide provides basic information for Unitronics controller model V350-35-T2. General Description
More informationEaton Innovative TechnologyT XT50/100 surge protective device
Instruction Manual IM01005014E Supersedes January 2014 Eaton T /100 surge protective device Contents Description Page Introduction.... 2 Installation.... 2 Specifications... 7 Operation..... 7 Warranty...
More informationB100 Installation Manual
Installation Manual Description The provides an additional voltage in a FlexPower system. This voltage can either be accessed directly via the 's terminals or through other FlexPower Accessory Boards.
More informationV TU24 V350-J-TU24
Vision PLC+HMI V350-35-TU24 V350-J-TU24 Installation Guide 12 Digital Inputs, including 2 Analog, 2 PT100/TC,1 HSC/Shaft-encoder input 12 Transistor Outputs General Description All of the controllers covered
More informationEthernet Test Access Panel (ETAP) User Manual
Ethernet Test Access Panel (ETAP) User Manual Content Page INTRODUCTION............................................................................. 1 Revision History........................................................................
More informationCA-A480-A Elevator Controller. Reference & Installation Manual
CA-A480-A Elevator Controller Reference & Installation Manual TABLE OF CONTENTS INTRODUCTION.................................................................. 4 Introduction.............................................................................................
More informationReplacing the Battery HP t5730 and t5735 Thin Clients
Replacing the Battery HP t5730 and t5735 Thin Clients Copyright 2009 Hewlett-Packard Development Company, L.P. The information contained herein is subject to change without notice. Microsoft and Windows
More informationHP R/T2200 UPS. Overview. Precautions. Installation Instructions. The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W.
HP R/T2200 UPS Installation Instructions Overview The HP UPS R/T2200 features power protection for loads up to 2200 VA/1600 W. For more information about any of the topics covered in this document, see
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide The information in this document is subject to change without notice. Hewlett-Packard Company makes no warranty of any kind with regard to this material, including, but not
More informationSATA II HDD Canister KISS DA 435 Quick Reference Guide
SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...
More informationTRC-190 User s Manual
User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only
More informationTorque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24
Torque Series LCD Remote Panel Installation/Operation Manual Model: TQ-DSP-12/24 Section Page Introduction 1 Materials Provided 1 I) Safety Instructions 1 A) Inverter Safety Instructions 1 B) Battery Safety
More informationInstallation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules
Installation Note for the Cisco ME 3800X and ME 3600X Switch Power Supply and Fan Modules This document provides the installation and removal instructions for the AC and DC input power supply and fan modules
More informationA Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks
The Network of Networks 3M High Density Cross-Connect Modules STG2000 Series The 3M High Density Cross-Connect Modules STG2000 Series are IDC copper cross-connects that can be used in a wide variety of
More informationInstalling The Loop Start Line Board In The FX Series Digital Communications System
R In The FX Series Digital Communications System Introducing The Loop Start Line Board Defining Loop Start The line board signals for the host system to complete a line connection by sending a supervisory
More informationInstallation and Getting Started Guide. HP ProCurve 600/610 External Power Supplies. PoE. Power over Ethernet Devices
Installation and Getting Started Guide HP ProCurve 600/610 External Supplies www.hp.com/go/hpprocurve PoE over Ethernet Devices HP ProCurve 600/610 External Supplies Installation and Getting Started Guide
More informationNext Generation Cross-Connect Crossbox Add-on Cabinet (NCX-XBA) User Manual
Next Generation Cross-Connect Crossbox Add-on Cabinet (NCX-XBA) User Manual ADCP-34-706 Issue 1 12/2008 23142-A Crossbox Add-on Cabinet 1457161 Rev A Preface COPYRIGHT All Rights Reserved REVISION HISTORY
More informationSurge Protective Devices Installation, Operation and Maintenance Manual. LoadTrack LTL
LoadTrack LTL Surge Protective Devices Installation, Operation and Maintenance Manual P.O. Box 3760 Winter Park, FL 32790 USA TEL: 800-647-1911 www.tpssurge.com LOADTRACK LTL INSTALLATION, OPERATION AND
More informationExplosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter
Installation, Operation & Maintenance Sheet Explosion-Protected Arc-Fault Protection ExAFCI Arc-Fault Circuit Interrupter > Contents 1 Contents 1 Contents...2 2 General Information...2 2.1 Manufacturer...2
More informationVision OPLC. V T38 Installation Guide. General Description
Vision OPLC V130-33-T38 Installation Guide The Unitronics V130-33-T38 offers the following onboard I/Os: 22 Digital Inputs, configurable via wiring to include 2 Analog and 2 HSC/Shaft-encoder Inputs 16
More informationExpandable Power Systems
Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.
More informationLINE VOLTAGE TESTER CT101 USER S MANUAL. Please read this manual carefully and thoroughly before using this product.
LINE VOLTAGE TESTER USER S MANUAL CT101 Please read this manual carefully and thoroughly before using this product. KEY FEATURES Visual indication of AC or DC voltage Easy to use approved Safe for CAT
More information4188, 4288, 4288-S and 4688 Protected Entrance Terminals
4188, 4288, 4288-S and 4688 Protected Entrance Terminals Instructions Underwriters Laboratories (UL) Listed January 1997 34-7041-3837-8 Revision A Contents: 1.0 General... 1 2.0 Accessories... 2 3.0 Protector
More informationInstallation Instructions
Installation Instructions (Cat. No. 1794-TBN) 6 1 5 9 4 2 3 10 6 7 8 Component Identification 1 Female flexbus connector 2 Terminal base unit (1794-TBN) 3 Male flexbus connector 4 Keyswitch Set to the
More informationPRINTER ACCESSORIES TECHNICAL DATASHEET UNIVERSAL REEL HOLDER
PRINTER ACCESSORIES TECHNICAL DATASHEET TTDS-260 issue 4, FEBRUARY 2018 UNIVERSAL REEL HOLDER The Universal reel holder is a free standing bench top, or wall mounted reel holder. Designed to dispense all
More informationOwner s Manual. TSD-DCPDV DC Power Distribution with Fixed & Variable Outputs. TSD-DCPDV DC Power Distribution. AtlasSound.com
Owner s Manual with Fixed & Variable Outputs 1 AtlasSound.com Owner s Manual Description The Atlas Sound Variable Block is designed to reduce cost and wiring clutter in installations where multiple DC
More informationQuickTouch (QT4) Owner s Manual
QuickTouch (QT4) Owner s Manual 4-Function Hand-Held Wireless Remote Control IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS Table of Contents SECTION I. APPLICATION...
More informationGeneral Description V TR34/V130-J-TR34 V TR34/V350-J-TR34 V430J-R34 V R34/V130-J-R34 V R34/V350-J-R34
Vision OPLC V130-33-TR34/V130-J-TR34 V350-35-TR34/V350-J-TR34 V430-J-TR34 V130-33-R34/V130-J-R34 V350-35-R34/V350-J-R34 V430-J-R34 Installation Guide 22 Digital Inputs, including 3 HSC/Shaft-encoder Inputs,
More informationSERVICE MANUAL MODEL SSW-520-F
SSW-520-F-ISSUE4.0 SERVICE MANUAL FOR MODEL SSW-520-F HANDS FREE STAINLESS STEEL TELEPHONE EQUIPPED WITH LOW POWER SPEAKER BOARD Serving the Telephone Industry Since 1930 Communication Equipment 519 West
More informationVisit us at
TM PRO3000 Toner and Probe Users Guide 99 Washington Street Melrose, MA 02176 Phone 781-665-1400 Toll Free 1-800-517-8431 Visit us at www.testequipmentdepot.com PN 2440799 (English) October 2005 2005 Fluke
More informationSMS 3xxx/SMS 4xxx Safety switch with separate actuator
Operating Instructions (Translation of the original instructions) SMS 3xxx/SMS 4xxx Safety switch with separate actuator SMS 3xxx SMS 4xxx Wieland Electric GmbH Brennerstraße 10-14 D-96052 Bamberg Tel.
More informationElectrical Management System (EMS) EMS-HW30C & EMS-HW50C
Electrical Management System (EMS) EMS-HW30C & EMS-HW50C Installation & Operating Guide for: Model EMS-HW30C Rated at 120V/30A and Model EMS-HW50C Rated at 240V/50A Surgio Says Lifetime Warranty on all
More informationElapsed Timer Control Panel
Installation Manual V6.2 Elapsed Timer Control Panel Current as of August 2017 The Sapling Company, Inc. Elapsed Timer Control Panel Table of Contents Table of Contents 2 Important Safety Instructions
More informationInstallation, Testing, and Operating Procedures 30 AMP PORTABLE AND PERMANENT SERIES GFCI SINGLE and MULTIPHASE
IMPORTANT! Please read all the information on this sheet. SAVE THESE INSTRUCTIONS! NOTICE BEFORE USING READ INSTRUCTIONS COMPLETELY. TO BE INSTALLED BY A QUALIFIED ELECTRICIAN IN ACCORDANCE WITH NATIONAL
More informationMODULAR PLUGS, ACCESSORIES AND TOOLING
MODULAR PLUGS, ACCESSORIES AND TOOLING 4th Edition Introducing the New Universal Contact BROADBAND NETWORK SOLUTIONS /// MODULAR PLUGS, ACCESSORIES AND TOOLING TE CONNECTIVITY MODULAR PLUG PORTFOLIO TE
More informationSite Preparation CHAPTER
CHAPTER 3 Site Preparation This chapter describes the steps to take and the considerations you should keep in mind prior to installing the modules in an open rack. It also contains information that applies
More information3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A
3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and
More informationREMOTE INPUT/ OUTPUT TERMINAL SYSTEM (RITS) CONNECTORS
REMOTE INPUT/ OUTPUT TERMINAL SYSTEM (RITS) CONNECTORS A concept that is saving your most valuable asset your time. The contact design based on insulation displacement of our RITS (Remote I/O Termination
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationTRC-190 User s Manual
First Edition, November 2008 www.moxa.com/product 2008 Moxa Inc. All rights reserved. Reproduction without permission is prohibited. The software described in this manual is furnished under a license agreement
More informationS82S (3/7.5-W Models)
Switch Mode Power Supply (3/7.5-W Models) CSM DS_E_4_3 Miniature DIN Rail Mounting DC-DC Power Supplies 65 mm depth enables mounting onto control panels with 100 mm depth. Inputs: 10.2 to 27.6 VDC (DC
More informationPV Rapid Shutdown device
PV Rapid Shutdown device Installation and Operation Manual Solis-RSD-1G(1:1) Solis-RSD-1G(2:2) Manufacturer: Ginlong (Ningbo) Technologies Co.,Ltd., Ningbo, Zhejiang, P.R.China US Office: 565 Metro Pl.
More informationMounting on the Ceiling Using Flush Mount (Face Down)
Mounting on the Ceiling Using Flush Mount (Face Down) Installation Guide 2014/02/14 Table of Contents Safety Information... 3 Installation Procedures... 5 Step 1: Drill a Hole on the Ceiling... 5 Step
More informationWhen any of the following symbols appear, read the associated information carefully. Symbol Meaning Description
Uni-I/O Wide Modules Installation Guide UIS-WCB1 Uni-I/O Wide is a family of Input/Output modules that are compatible with the UniStream control platform. Wide Modules are 1.5 times as wide as Uni-I/O
More information3M Constant Monitors WSMONITOR1, WSMONITOR 2, WSMONITOR3
3M Constant Monitors WSMONITOR1, WSMONITOR 2, WSMONITOR3 User s Guide WSMONITOR1 WSMONITOR2 WSMONITOR3 Table of Contents Section Page SAFETY INFORMATION...3 Introduction...5 Installation...6 Operation...9
More informationINSTALLATION INSTRUCTIONS
TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215
More informationInstallation RA5112-C-16A-C20. Basic Rack Power Distribution Unit
Installation RA5112-C-16A-C20 Basic Rack Power Distribution Unit Contents Before You Begin........................1 Safety and grounding information..........1 How to Install the Rack PDU...............2
More informationInstalling And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems
R Installing And Programming The Analog Terminal Interface On The DXP, DXP Plus, and FX Series Digital Communications Systems The Analog Terminal Interface The ATI-D-1PT is a multipurpose, on-premise accessory
More informationInstallation Instructions & User Manual POWERWARE TVSS ZONESENTINEL. AC Panel Transient Voltage Surge Suppressors
Installation Instructions & User Manual POWERWARE TVSS ZONESENTINEL AC Panel Transient Voltage Surge Suppressors INTRODUCTION This document explains how to install the Powerware TVSS ZoneSentinel AC Panel
More informationUpgrading and Servicing Guide
Upgrading and Servicing Guide The only warranties for Hewlett-Packard products and services are set forth in the express statements accompanying such products and services. Nothing herein should be construed
More informationCIB 3125 (122A) Off-Premises Range Extender. Installation Instructions. Installed By Qualified Technician Only CIB
CIB 3125 (122A) Off-Premises Range Extender Installation Instructions Installed By Qualified Technician Only CIB 3125 106793441 1992 AT&T All Rights Reserved Printed in USA Issue 3 August 1992 NOTICE Every
More informationhp uninterruptible power system r12000 xr models installation instructions
hp uninterruptible power system r000 xr models installation instructions Overview These instructions show how to install an uninterruptible power system (UPS). For detailed information about the UPS, refer
More information