Bill of Quantity (BoQ)

Size: px
Start display at page:

Download "Bill of Quantity (BoQ)"

Transcription

1 Section-9 Bill of Quantity (BoQ)

2 A) SCADA/DMS control centre (BoQ) Sl.No. Specification Towns under RAPDRP project area Equipment A1 Server/ workstation Hardware 1 SCADA/DMS server No FEP server with interface switches No ISR server No NMS server No DTS server No Developmental server No Communication Server No Web/Directory server No Workstation with dual TFT Monitors No Remote VDUs with one TFT Monitors No Developmental console with one TFT No DTS/Workstation Console with dual TFTs No DLP based Video Projection system with 2X3 Module configuration with each module at least 67" diagonal with common projector Storage & Backup Devices Unit Set Baroda Ahmdabad Rajkot Jamnagr Bhavnagar Surat Total

3 14 External RAID Mass storage device ( for 2 months online backup) 15 External DAT drive (160/320GB) Switches/Routers 16 Layer II switch (SCADA/DMS LAN) Layer II switch ( Development system LAN &DTS) Routers for interfacing (ITDC and IT CC),SLDC,FRTU No No No No No Router at remote VDU No Firewall & network IPS Nos. Other Active devices 21 GPS Time synchronization system set Time, day & date digital displays set Printers 23 A3 Color inkjet printer No B/W Laser printer No Color Laser printer No Security system (DMZ) 26 Web server with load balancing and mail server No Mail server No Router No Firewall & network IDS,IPS No

4 30 Layer II switch No Cabling System 31 Cable, Jacks etc. Lot Any other hardware to meet functional /performance Lot requirement of MTS(One Plotter and Scanner) A2 Mandatory Spares for Control Centre 33 5% of A1 % A3 Software for Control Centre 34 SCADA software Lot ISR Software Lot DMS software Lot DTS software Lot Developmental software Lot Network Management Software Lot WEB /Network security software(incl in web server) Lot 41 RDBMS package (incl in ISR) Lot 42 GIS Adaptor/Engine for importing data from GIS system under IT system 43 Any other software to meet functional /performance requirement of MTS (OMS etc) A4 Network Charges Lot Lot

5 p.a per RTU/FRTU/FPI 44 Network Connectivity Charges for Link for 1 year post commissioning(mpls-vpn) B) SCADA/DMS DR Centre SL.No. Specification Towns under RAPDRP project Equipment B1 DR server 1 DR server Nos Communication Server Nos Workstation with one TFT Monitors Nos 2 2 B2 Storage & Backup Devices 4 External storage device Nos External DAT drive Nos 2 2 B3 Switches 6 Layer II switch (DR LAN) Nos 2 2 Routers Unit Baroda Ahmdabad Rajkot Jamnagr Bhavnagar Surat Total

6 7 Router for interfacing at SCADA DMS Centre Nos 1 1 B4 Printers 8 Color inkjet printer Nos B/w Laser printer Nos Color laser printer Nos 0 0 B5 Cabling System 11 Cable, Jacks etc. Nos Any other hardware to meet functional /performance Nos requirement of MTS 0 0 B6 Mandatory spares for DR Centre % 13 5% of B1+B2+B3+B4+B5 5 5 B7 Software for DR Centre 14 RDBMS (Included in server) 0 0

7 C) Remote terminal unit Items Towns under RAPDRP project SL.No. Equipment Unit Baroda Ahmdabad Rajkot Jamnagr Bhavnagar Surat Total RTU comprising panels, racks, sub-racks, Power Supply modules, CPU analog / digital input & control output,module as per specification interfacing equipment, required converters & all other required,items/accessories including complete wiring for all modules for locations mentioned below Nos 2 MFTs Nos CMRs Nos HDR Nos Dummy Breaker Latching Relays Nos Weather transducer - Wind speed Nos Weather transducer rainfall Nos Weather transducer - Humidity Nos Weather transducer -Temperature Nos Weather transducer -Wind Direction Nos modem Nos Router Nos Single TFT PC for LDMS with all accessories and UPS Nos B/W laser printer Nos

8 Any other hardware to meet functional /performance Nos requirement of 15 MTS C2 Local Data Monitoring System (LDMS) 16 LDMS Nos Any other software to meet functional /performance requirement of MTS Nos C3 TEST EQUIPMENTS for RTU RTU Database Configuration & Maintenance Software tool Nos Master Station cum RTU Simulator & Protocol analyser 19 software tool Nos Laptop PC for above software tools along with 20 interfacing hardware including Hub Nos C4 MANDATORY SPARES FOR RTU 5% of c1 Nos Sub - Total (mandatory spare) -D4 Nos C5 Bandwidth Charges Nos Network Connectivity Charges for Primary Link (SCADA/DMS main control centre) Nos Sub - Total (bandwidth charges) -D5

9 RTU I/O COUNT Baroda Town Sl.No STATION SS DS DC AI CMR HDR MFT ATLADRA COM MOD ULE (Serial ) DI MODUL E DO MODULE AI MODUL E 2 CHHANI-A CHHANI-B GAJARAWADI GORWA GOTRI HARNI INDRAPURI MAKARPURA MOTIBAUG NAVLAKHI SAMA

10 SUBHANPURA TARSALI VIDYUTNAGAR Total Total with 20% spare RTU I/O COUNT :Ahmdabad Town SNO STATION SS DS DC AI CMR HDR MFT COM DI DO AI MODULE MODULE MODULE MODULE Naroda Odhav Muthiya Kanbha Bhat Adalaj

11 Science city Bopal Sanathal Sabarmati Kathwada Koba Khoraj Shela Ambli GopulDham Unali TOTAL TOTAL WITH 20% SPARE

12 RTU I/O COUNT Rajkot Town SNO STATION SS DS DC AI CMR HDR MFT COM MODUL E DI MODUL E DO MODU LE AI MODU LE Dudhasagar Ghanteshwer GIDC KOTHRIYA Laxminagar Mavdi Navagam Popatpara Punitnagar Raiyadhar Vajdi SS Shsashtrimaidan

13 University Road Nilkanth Racecourse TOTAL TOTAL WITH 20% SPARE RTU I/O COUNT Jamnagar Town SNO STATION SS DS DC AI CMR HDR MFT COM MODULE DI MODULE DO MODULE AI MODULE NAGHEDI SATRASTA M P SHAH C SS HAPA B SS MORKANDA

14 8 Power house Total Total With 20% Spare RTU I/O COUNT : Bhavnagar Town SNO STATION SS DS DC AI CMR HDR MFT Chitra City SS Nari road Sidasar Vartej Sardar nagar Desai nagar COM DI DO AI MODULE MODULE MODULE MODU LE

15 8 Valket gate TOTAL Total with 20% Spare RTU I/O COUNT : Surat Town SNO STATION SS DS DC AI CMR HDR MFT KV TAPI KV SERTHANA KV PUNA KV BHESTAN KV PANDESRA - A KV PANDESRA - B KV GOVALAK KV GODADARA COM DI DO AI MODULE MODULE MODULE MODU LE

16 KV UDHNA KV SACHIN-A KV SACHIN-B KV KHAJOD KV KAMREJ KV LASKANA KV VESU KV PAL KV VARIYAV KV KOSMADA Pala Ichapore Kosad Jiav Vanz

17 24 Sachin-C TOTAL Total with 20% Spare Note: - SS : Single status input, DS : Double status input for CBs, DC : Digital Control Output Trip / Close/Raise /lower, CMR : Contact Multiplying Relay, HDR : Heavy Duty Relay, MFT : Multi function Transducers, CM: Communication Module, DI : Digital input, DO : Digital Output AI: Analog module Note: 1. MFT provide data that is to be acquired by RTU on Modbus/or IEC protocol for Voltage (phase to phase and phase to neutral),current (phase and neutral), Active Power, Reactive Power, Apparent Power, Power Factor, Frequency, active energy (import & export), reactive energy (import & export) etc. 2. CMRs shall be mounted in the existing C&R panels. Wherever the space is not available in the existing panels the same shall be mounted in the RTU panels. Heavy Duty Relays shall be provided for Digital outputs for CBs and shall be mounted in the RTU panels itself. 3. The RTU shall be equipped for the above specified I/O (analog input MFT), digital input & digital output) point points, which includes 20 % spare for future use. These 20 % spare points shall be terminated on terminal blocks in RTU panel. 4. All protection relay/alarm points & CBs shall be considered for SOE. 5. Point counts include three alarms per station for auxiliary system and fire, which shall be interfaced to RTU.

18 Item D) Feeder Remote terminal Unit(FRTU) Unit Towns under RAPDRP project area D1 FRTUs Mini pole mounted FRTU base equipment along with enclosure suitable to work in open environment (Adequate protection from water & dust), racks, sub-racks, Power Supply modules with power backup, I/o modules, CPU, interfacing equipment, required converters & all other required items/accessories including complete wiring for all modules for locations mentioned BELOW Set MFTs Nos CMRs Nos HDR Nos Dummy breaker latching Relay Nos Modem Nos Any other ITEM to meet functional /performance requirement of MTS D2 TEST EQUIPMENTS for FRTU FRTU Database Configuration & Maintenance Software tool Nos Master Station cum RTU Simulator & Protocol analyzer software tool Nos Laptop PC for above software tools along with interfacing hardware including Hub Nos Baroda Ahmdabad Rajkot Jamnagar Bhavannagar Surat Total

19 D3 MANDATORY SPARES FOR FRTU % D4 Bandwidth Charges Network Connectivity Charges for Primary Link (SCADA/DMS main control centre) *CMRs and HDR are indicative and it may be considered as per requirement FRTU IO List Discom Town Name Type of equipment Locations SS DS DC AI CMR HDR MFT COM MODULE DI MODULE DO MODULE AI MODULE RMU MGVCL Baroda Sectionalizer RMU UGVCL Ahmdabad Sectionalizer RMU Rajkot Sectionalizer RMU Jamnagar Sectionaliser RMU PGVCL Bhavnagar Sectionaliser RMU DGVCL Surat Sectionaliser

20 1. MFT provide data that is to be acquired by FRTU on Modbus/or IEC protocol for Voltage (phase to phase and phase to neutral),current (phase and neutral), Active Power, Reactive Power, Apparent Power, Power Factor, Frequency, active energy (import & export), reactive energy (import & export) etc. 2. CMRs shall be mounted in the existing C&R panels. Wherever the space is not available in the existing panels the same shall be mounted in the FRTU panels. Heavy Duty Relays shall be provided for Digital outputs for CBs and shall be mounted in the FRTU panels itself. 3. The FRTU shall be equipped for the above specified I/O (analog input MFT), digital input & digital output) point points, which includes 20 % spare for future use. These 20 % spare points shall be terminated on terminal blocks in FRTU panel. 4. All protection relay/alarm points & CBs shall be considered for SOE. 5. Point counts include three alarms per station for auxiliary system and fire, which shall be interfaced to FRTU.

21 E) Communication Equipments E2) Communication system - VPN (MLLN/ MPLS) Broadband R-APDRP Project Area Sl.No Item Unit 1 Network Connectivity Charges for 2Mbps MLLN-broadband Link Nos Network Connectivity Charges for 64Kbps MLLN-broadband Link Nos Network Connectivity Charges for 2Mbps MPLS-broadband Link (RTUs,SLDC,,IT DC, CCC,DR and Remote VDU) Nos 4 Network Connectivity Charges for 64Kbps MPLS-broadband Link Nos Network connectivity charges for FRTUs &FPIs on G/CDMA/GPRS Nos Network Connectivity Charges for existing leased line from BSNL (Actual avg charges per link per annum) Nos Baroda Ahmdabad Rajkot Jamnagar Bhavannagar Surat Total

22 E3) Communication system - MAR/Radio R-APDRP project Area Item Unit E3A Hardware/ Equipment MAR/Radio terminal equipment No Antenna OMNI directional antenna unidirectional antenna Radio modems E4) Wireless communication modems E4A Unit Baroda Ahmdabad Baroda Ahmdabad Rajkot R-APDRP Project Area Rajkot Jamnagar Jamnagar Bhavannag ar Item:RMU,Sectionalizer& FPI Modems 1 GPRS No CDMA EDGE G No Bhavannagar Surat Surat Total

23 Item F1 Main Equipments - Control centre F) Auxiliary Power supply Set of 1 UPS with suitable rating running in parallel redundant mode* (20 KVA) two VRLA type Battery banks for above UPS for minimum 30 mts.backup 2 duration (set included in Above) set DC Power Supply (DCPS) system based on SMPS (for 20 A 3 load plus charging current@10% capacity) Set Battery bank for above DCPS (VRLA Type) for minimum 4 hrs backup 4 (Set included in above) Set F2 Main Equipments - DR Centre Main Equipments 5 UPS with suitable rating running in parallel redundant mode* 1 1 VRLA type Battery banks for above UPS for minimum 30 min. backup 6 duration DC Power Supply (DCPS) system based on SMPS (for 20 A load plus 7 charging current@10% capacity) 1 1 Battery bank for above DCPS (VRLA Type) for minimum 4 hrs backup (Set included in above) 8 F3 Mandatory Spares for UPS % F4 Mandatory Spares for DCPS % F5 For RTU / Data Concentrator / Communication Eqpts. Unit Baroda Ahmdabad Rajkot Jamnagar Bhavannagar Surat Total

24 9 DC Power Supply (DCPS) system based on SMPS Battery bank for above DCPS (VRLA Type) for minimum 4 hrs backup 10 (included above) F6 For FRTU 11 48V DC Power Supply (DCPS) system based on SMPS Battery bank for above DCPS (VRLA Type) for minimum 4 12 hrs backup F7 Remote VDU Locations 13 UPS (2 kva ) No List of mandatory spares shall be provided by the contractor upto 5 % of the total cost to meet the availability requirements. Failure to maintain the same would be liable for suitable penalty. Inventory for the same shall be maintained during FMS period of 5 years. G) Training Sr. No Description Duration in days No. Of Trainees A. Operator s Training 1 Operator for SCADA/DMS Control Centre 5 1 Per workstation console/ shift at control centre 2 Instructor for DTS 10 3 B. Maintenance Training 1 Computer Hardware & System Software 10 2

25 2 Application Software (SCADA/DMS) RTU & FRTU Database & display development Auxiliary Power Supply Communication System including NMS 5 2 Note: Minimum training requirement are given in G, however the no.of days may change as per actual requirement FMS S.No. Description Duration 1 FMS charges for SCADA/DMS system (maintaining overall system availability as per MTS) 2 FMS charges for SCADA/DMS system (maintaining availability individual hardware & non critical functions as per MTS) Five Year Five Year 3 Total FMS charges Five Year : 1. The necessary spares required for maintenance of the system during FMS shall be provided by the contractor. However, the consumables shall be provided by the owner. 2. FMS shall include all the supplied hardware & software under the project.

26 I) IMPLEMENTATION SCHEDULE S. No. Items Completion Schedule from the Award of Contract 1 SCADA/DMS System 18 months BIDDER SHALL PROVIDE IMPLEMETATION SCHEDULE INDICATING MILESTONES

27 *******************************End Of Document****************************

APPENDIX- G(OPTION I) Table-1

APPENDIX- G(OPTION I) Table-1 APPENDIX- G(OPTION I) Table- BILL OF QUANTITY FOR SCADA/EMS SYSTEM OF DEHRADUN SLDC Item no. ITEM DESCRIPTION UNIT QTY A SCADA/EMS APPLICATION SOFTWARE: SCADA Lot RTU Data Acquisition Data Exchange Data

More information

Automation in Large Urban Power Distribution System. Dr. K Rajamani CENTRAL TECHNICAL SERVICES, RELIANCE ENERGY LIMITED, MUMBAI

Automation in Large Urban Power Distribution System. Dr. K Rajamani CENTRAL TECHNICAL SERVICES, RELIANCE ENERGY LIMITED, MUMBAI Automation in Large Urban Power Distribution System Dr. K Rajamani CENTRAL TECHNICAL SERVICES, RELIANCE ENERGY LIMITED, MUMBAI Need for Automation and Current trends Automation Systems and Functionality

More information

Section -2, Chapter -5 HARDWARE REQUIREMENTS FOR SCADA/DMS

Section -2, Chapter -5 HARDWARE REQUIREMENTS FOR SCADA/DMS Section -2, Chapter -5 5.0 Introduction HARDWARE REQUIREMENTS FOR SCADA/DMS This section articulates the hardware requirements for the SCADA/DMS system. The conceptual hardware configuration diagram of

More information

Remote Terminal Unit ER1000 APPLICATION FEATURES

Remote Terminal Unit ER1000 APPLICATION FEATURES Remote Terminal Unit ER1000 ERL with more than three decades of expertise in Power System Protection have developed state of the art Automation Solutions. The whole family of ERL s Remote Terminal Unit

More information

Queries / Modifications / Changes Suggested

Queries / Modifications / Changes Suggested NIT No. RECPDCL/TECH/SCADA-CED/e-Tender/2016-17/3931 Dated: 09.03.2017 Amendment-1 Dated:31.03.2017 S. No. Item Page No. / Clause No. Technical Specifications as per RFP Queries / Modifications / Changes

More information

POWER GRID AUTOMATION. Pág.. n. RMU Automation

POWER GRID AUTOMATION. Pág.. n. RMU Automation POWER GRID AUTOMATION RMU Automation Distribution Network Non-Controlled Secondary Distribution Systems Distribution Network RMU Automation - Levels RMU Automation - RTU / FRTU SMART CONTROLLER Monitoring

More information

E1-E2 (EB) Chapter 1 MLLN

E1-E2 (EB) Chapter 1 MLLN E1-E2 (EB) Chapter 1 MLLN MLLN Drawback Of Traditional Leased Line Circuits No Intramedia in between. Grew from 64 kbps they have to jump over to 2 Mbps only. Data Cards support only upto 64 Kbps From

More information

1 Page No. 20, 21 & 22 Form factor. This should be read as 1U/2U Rack Mountable

1 Page No. 20, 21 & 22 Form factor. This should be read as 1U/2U Rack Mountable Karnataka State Natural Disaster Monitoring Centre (Affiliated to Dept. of Science & Technology, Govt. of Karnataka) Pre-bid meeting held on 22.12.2009 Corrigendum RACK SERVERS, SAN Storage, TAPE library,

More information

A Case Study: SCADA Implementation in KPTCL

A Case Study: SCADA Implementation in KPTCL A Case Study: SCADA Implementation in KPTCL Vinuta V Koluragi M.Tech(Power and Energy Systems) Assisstant Professor B.L.D.E.A s V P Dr P. G. Halakatti College of Engg. & Tech., Bijapur. Abstract: Development

More information

Server/ Engineering Station. Filed Instrument. Filed Instrument. Filed Instrument. Switches. Fig1: Scheme for micro PLC to Master PLC Interface

Server/ Engineering Station. Filed Instrument. Filed Instrument. Filed Instrument. Switches. Fig1: Scheme for micro PLC to Master PLC Interface PC Micro PLC HMI HMI Master PLC Server/ Engineering Station Filed Instrument Switches Filed Instrument Filed Instrument Fig1: Scheme for micro PLC to Master PLC Interface PC Historian Server Communication

More information

MW/MVAR Transducer Specifications

MW/MVAR Transducer Specifications GUARANTEED TECHNICAL PARTICULARS (To be submitted by bidder with the tender) MW/MVAR Transducer Specifications Sr.No. Descriptions Details Offered by supplier 1 2 3 4 Transducer suitable for Input Output

More information

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES

MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES MONITORING AND CONTROL REQUIREMENTS FOR DISTRIBUTED GENERATION FACILITIES 1. Introduction Real time monitoring and control is necessary to ensure public and employee safety and to protect the integrity

More information

SECTION -2, CHAPTER -1 SCADA FUNCTIONS

SECTION -2, CHAPTER -1 SCADA FUNCTIONS 1.0 General requirements SECTION -2, CHAPTER -1 SCADA FUNCTIONS This section describes the functions to be performed by the SCADA applications for distribution system for the project area. Bidders are

More information

Fault and outage management

Fault and outage management WEBINAR, SEPTEMBER 2017 Distribution Automation for electrical grids Fault and outage management Alain Aurus, Theodoros Oikonomou, Yasmine Vögele Introduction Facility Management Use the detach button

More information

Veesta World Co. V-SCADA2000 Product Series. The cross platform SCADA system

Veesta World Co. V-SCADA2000 Product Series. The cross platform SCADA system Veesta World Co. V-SCADA2000 Product Series The cross platform SCADA system 1 V-SCADA2000 Product Series 2 V-SCADA2000 Veesta SCADA Control System 2000 Product Series Overview V-SCADA2000 Series consist

More information

Blackout 101. Dr. B. Don Russell Texas A&M University. Dr. Bruce Wollenberg University of Minnesota. Mr. John McDonald KEMA, Inc.

Blackout 101. Dr. B. Don Russell Texas A&M University. Dr. Bruce Wollenberg University of Minnesota. Mr. John McDonald KEMA, Inc. Blackout 101 Dr. B. Don Russell Texas A&M University Dr. Bruce Wollenberg University of Minnesota Mr. John McDonald KEMA, Inc. Dr. Pete Sauer University of Illinois at Urbana-Champaign An Electric Power

More information

The Smart Utility Meets The Smart tgid Grid. The Smart. Bob Uluski. Technology Quanta Technology LLC

The Smart Utility Meets The Smart tgid Grid. The Smart. Bob Uluski. Technology Quanta Technology LLC The Smart Utility Meets The Smart tgid Grid The Smart Substation Bob Uluski Quanta Technology Why is the Smart Substation Key power apparatus important? for maintaining the reliability and efficiency of

More information

Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control

Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control Welcome to NovaTech Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control Paul Grabowski About the Author Paul Grabowski

More information

BSES Smart Grid Road Map

BSES Smart Grid Road Map BSES Smart Grid Road Map Rajesh Bansal, Head (Network Operations), BSES Delhi BSES Delhi Discoms A Synopsis NDPL BRPL BYPL Reliance Infrastructure Ltd. acquired 51% stake in July 2002 in two Discoms MES

More information

CESC Limited Power Distribution for the Future August BCC & I - Power Distribution for the Future

CESC Limited Power Distribution for the Future August BCC & I - Power Distribution for the Future CESC Limited Power Distribution for the Future August 2016 www.cesc.co.in debasis.gupta@rp-sg.in 1 1 Power Distribution for the Future In the coming years, Utilities would need to: Expand the network to

More information

TECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1)

TECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1) TECHNICAL SPECIFICATION OF GPRS based MODEM (Part 1) 1. SCOPE: The scope of work is on turn-key basis covering modem supplies, solution engineering. Supply of GPRS Modems for data acquisition from HT/

More information

MIC-2 Multi-instrument DATA SHEET

MIC-2 Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional) Profibus DP (optional) I/O modules

More information

National Competitive Bidding (NCB) Single Stage Two Cover System

National Competitive Bidding (NCB) Single Stage Two Cover System National Competitive Bidding (NCB) Single Stage Two Cover System BIDDING DOCUMENT For Procurement of the work Tender for the Supply, Installation and Commissioning of CCTV Surveillance System in Velankanni

More information

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET

MIC-2 MKII & MIC-2 MKII DIN, Multi-instrument DATA SHEET & DIN, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Bilfinger Mauell GmbH. smartrtu ME 4012 PA-N

Bilfinger Mauell GmbH. smartrtu ME 4012 PA-N smartrtu ME 4012 PA-N ME 4012 PA-N is a universal telecontrol device for all uses which is primarily intended for monitoring and control tasks in wind parks, local network stations, gas pressure regulating

More information

Johan Hoolsema Expert System Solutions

Johan Hoolsema Expert System Solutions The Efficient Way of Using TETRA for Smart Grids and Telemetry Applications TCCA Amsterdam 31 May 2016 Johan Hoolsema Expert System Solutions TCCA SCADA, Smart Grid and Telemetry (SST)Group 1 One stop

More information

THE RAINBOW SCADA D-700

THE RAINBOW SCADA D-700 THE RAINBOW SCADA D-700 INTERNET ENABLED SYNCHRONIZATION SYSTEM REV-03 25.12.2014 EXPANSION CAPACITY MAX 16 LOADS MAX 48 GENSETS MAX 4 BUS COUPLERS MAX 16 MAINS MULTIFUNCTIONAL THE SAME UNIT IS A... MULTI-GENSET

More information

4 Is this model available for special primary current and special primary voltage?

4 Is this model available for special primary current and special primary voltage? Category: Sales 1 Is it possible to exchange the backlights? The backlights are LED, no need to exchange. Fukuyama Works, Mitsubishi Electric Corporation March, 2018 2 Which standards does this model support?

More information

ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS

ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 ELECTRICAL PLANT CONCEPT The electrical equipment, depending

More information

AUTOMATION OF POWER DISTRIBUTION USING SCADA

AUTOMATION OF POWER DISTRIBUTION USING SCADA 1 2 ABSTRACT In every substation certain measurements, supervision, control, operation and protection functions are necessary. Traditionally these functions were performed manually by system operator from

More information

6 Cell 180 Cell 244 Cell 589 Cell 246 Cell 400 Cell 24 Cell 52 Cell 5 Set 4 Unit (contact CIF) 15 Piece Carrier relay multiplex converter

6 Cell 180 Cell 244 Cell 589 Cell 246 Cell 400 Cell 24 Cell 52 Cell 5 Set 4 Unit (contact CIF) 15 Piece Carrier relay multiplex converter The main procurement plan in fiscal 2018 *We are considering implementation methods and timing aiming for thorough efficiency improvement. Long life control valve type storage battery 40Ah 2V 1cell 6 Cell

More information

SM100. On-Line Switchgear Condition Monitoring

SM100. On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring On-Line Switchgear Condition Monitoring Introduction Weis is a specialist company with over 40 years of experience in the commissioning, testing & maintenance of

More information

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723

IP68. Autarkic Data Loggers - MT-051 / MT-713 / MT-723 Autarkic Data Loggers - MT-051 / MT-713 / MT-723 Use in the most demanding environments These data loggers are designed for use in difficult to reach and widely distributed locations. In places where neither

More information

MP7. Uninterruptible Power Supply

MP7. Uninterruptible Power Supply Uninterruptible Power Supply PRODUCT SPECIFICATIONS Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

Remote Real-Time Measurements of Voltage, Current and Energy

Remote Real-Time Measurements of Voltage, Current and Energy Remote Real-Time Measurements of Voltage, Current and Energy Chris Yakymyshyn Pam Hamilton Michael Brubaker yakymyshyn@fieldmetricsinc.com 727-319-0299 Slide 1 Outline Introduction FieldMetrics (FMI) Products

More information

'B', 'C' and 'D' 'àh Annexure 'Sk. Dated RFP for

'B', 'C' and 'D' 'àh Annexure 'Sk. Dated RFP for Govemment of Jammu and Kashmir Jammu S Kashmir e-governance Agency Civil gecretariat, SrinagarlJammu No. JaKeGAI GEN/oâl 2011-11 Dated 27419-2013 Subject: Re uest for Pro osal RFP for establishment of

More information

Network Planning for Smart Grid

Network Planning for Smart Grid Network Planning for Smart Grid UTC Telecom 2009 June 3, 2009 David Boroughs Experience you can trust. Objectives Smart Grid Architecture Overview Network Planning & Dimensioning Aspects Network Performance

More information

AMR and SCADA in Outage Management System for MSEDCL Sangita B. Patil 1, Bapu K. Patil 2

AMR and SCADA in Outage Management System for MSEDCL Sangita B. Patil 1, Bapu K. Patil 2 e-issn: 2349-9745 p-issn: 2393-8161 Scientific Journal Impact Factor (SJIF): 1.711 International Journal of Modern Trends in Engineering and Research www.ijmter.com AMR and SCADA in Outage Management System

More information

Bombay Stock Exchange Limited

Bombay Stock Exchange Limited Bombay Stock Exchange Limited APPLICATION FOR NETWORK CONNECTIITY FOR CDSL OPEARTION To be filled in by the CDSL Member and submitted to CDSL 16 th Floor, P.J. Towers, Mumbai 400 001. 1. Participant details

More information

Sensaphone SCADA 3000 APPLICATION SUPPORT BULLETIN Single-Frequency Radio

Sensaphone SCADA 3000 APPLICATION SUPPORT BULLETIN Single-Frequency Radio Sensaphone SCADA 3000 APPLICATION SUPPORT BULLETIN Single-Frequency Equipment requirements for a typical Sensaphone SCADA 3000 application using licensed, single-frequency radio modems. The purpose of

More information

Specifications SmartACU2000B-D-PLC SmartACU2000B-D-2PLC SmartACU2000B-D-PID/PLC SmartACU2000B-D-2PID/2PLC Configuration

Specifications SmartACU2000B-D-PLC SmartACU2000B-D-2PLC SmartACU2000B-D-PID/PLC SmartACU2000B-D-2PID/2PLC Configuration ACU2000B ACU2000B ( Array Controller) is a powerful integration of PV array communication and other smart functions. What s more, it supports 1000V/1100V/1500V DC system perfectly. built-in PID2000 module

More information

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7

R E C T I F I E R I N V E R T E R C O N V E R T E R MP7 Uninterruptible Power Supply Product Specifications Description The industrial UPS provides your critical equipment with uninterruptible 3 phase AC power. Using high frequency dual conversion technology,

More information

BOQ CUM RATE SCHEDULE FOR C AND I WORKS AT 3x 500 MW APCPL JHAJJAR UNIT 1TO 3 TENDER NO. BHEL/NR/SCT/JHAJJAR/CNI/662

BOQ CUM RATE SCHEDULE FOR C AND I WORKS AT 3x 500 MW APCPL JHAJJAR UNIT 1TO 3 TENDER NO. BHEL/NR/SCT/JHAJJAR/CNI/662 PANELS / CONSOLES / RACKS 1 2 CONTROL CABINETS FOR S.G. (750L X 2355H X 750W) CONTROL CABINETS FOR T.G. (750L X 2355H X 750W) No. 164 No. 121 3 4 5 6 7 8 9 10 11 12 13 14 CONTROL CABINETS FOR MMI (750L

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

PowerStudio is simple, powerful and user-friendly software. Provides complete monitoring of energy in industrial and commercial buildings.

PowerStudio is simple, powerful and user-friendly software. Provides complete monitoring of energy in industrial and commercial buildings. Circutor - Founded in 1973 in Barcelona, Spain - Wide product portfolio with solutions for energy metering systems, equipment for protection and energy management - Solutions for EnMS, reactive power compensation,

More information

KENDRIYA VIDYALAYA SANGATHAN

KENDRIYA VIDYALAYA SANGATHAN KENDRIYA VIDYALAYA SANGATHAN BENCHMARKING OF COMPUTER LABORATORY NEED FOR COMPUTER LABORATORIES IN KENDRIYA VIDYALAYAS Computer teaching plays a key role in the modern systems of education. The ability

More information

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications

Dupline. Data Logger. Types G , G Product Description. Ordering Key G Type Selection. Input/Output Specifications Dupline Data Logger Types G 800 006, G 800 106 Product Description Programmable channel generator with optional built-in GSM Modem Event and time based data logging functions for digital, analog and counter

More information

I/A Series HARDWARE Product Specifications

I/A Series HARDWARE Product Specifications I/A Series HARDWARE Product Specifications I/A Series Remote Terminal Unit (RTU) C50 3 Phase Digital Transducer Module FEATURES Simultaneous sampling eliminates skew error Replaces MW, MVAR, MVA, Volts,

More information

A platform to build smart solutions for everyday ease

A platform to build smart solutions for everyday ease A platform to build smart solutions for everyday ease The Internet of Things (IoT) is an environment in which objects, animals or people are provided with unique identifiers and the ability to transfer

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power 1. Abstract Dinesh Mithanthaya Design Manager, Horizon Power Higher capacity substation power transformers ( 5MVA),are

More information

E3-E4 E&WS Rev date: CHAPTER-9 MLLN. For Internal Circulation of BSNL Only. BSNL, India. Page: 1

E3-E4 E&WS Rev date: CHAPTER-9 MLLN. For Internal Circulation of BSNL Only. BSNL, India. Page: 1 CHAPTER-9 MLLN Page: 1 MLLN An Overview 1.0 Leased Line Introduction A leased circuit is a dedicated link provided between two fixed locations for exclusive use of the customer. It is a dedicated point

More information

2 NOVATECH. This page is intentionally left blank.

2 NOVATECH. This page is intentionally left blank. NovaTech Orion I/O 2 NOVATECH This page is intentionally left blank. ORION I/O 3 NovaTech Orion I/O Overview NovaTech Orion I/O is an extension of the family of OrionLX Automation Platforms for substation

More information

SCADA Solutions for Water and Wastewater Treatment Plants

SCADA Solutions for Water and Wastewater Treatment Plants SCADA Solutions for Water and Wastewater Treatment Plants Features Centralized control Increased reliability Improved management of treatment processes Reduced costs Preserved equipment investments Flexible

More information

FEATURES DESCRIPTION FEATURES

FEATURES DESCRIPTION FEATURES FEATURES Two High Speed Counters Two Pulse Train Outputs Two Pulse Width Modulation Outputs 24 Sinking or Sourcing Inputs 16 Outputs 1 RS232 Port 2 RS485 Ports Supports Modbus RTU Protocol Communicate

More information

Smart. Simple. Reliable. 600mm 1,100mm 600mm ( ft.) Weight 80 kg (176.4 lb.) [1] Protection Rating Ground-Mounted, Wall-Mounted, Rack-Mounted

Smart. Simple. Reliable. 600mm 1,100mm 600mm ( ft.) Weight 80 kg (176.4 lb.) [1] Protection Rating Ground-Mounted, Wall-Mounted, Rack-Mounted ACU2000 Series ACU2000 ( Array Controller Unit) is a powerful integration of PV array communication and other smart functions. built-in Anti-PID module built-in (optional) Multiple communication interfaces

More information

TECHNICAL DESCRIPTION

TECHNICAL DESCRIPTION MPi80HD TECHNICAL DESCRIPTION 1 GENERAL DESCRIPTION The MPi80HD system is designed to convert AC mains voltage into 48 VDC and to supply telecom equipment with battery back up. The MPi80HD can house up

More information

NX21 USER MANUAL. Telemetry Unit. Version 1.5

NX21 USER MANUAL. Telemetry Unit. Version 1.5 USER MANUAL Version 1.5 Nortech Management Ltd, United Kingdom NOV 2016 www.nortechonline.co.uk Doc Ref D_000344 Publication Notice Copyright Nortech Management Limited (NML). All rights reserved. No part

More information

Small Generator Interconnection System Impact Study Report. Completed For Q0047

Small Generator Interconnection System Impact Study Report. Completed For Q0047 Small Generator Interconnection Completed For Q0047 Proposed Interconnection PacifiCorp s Existing Goshen Rigby 69 kv Line March 7, 2005 1.0 Description of the Generation Facility Q0047 ( Interconnection

More information

NovaTech Orion I/O Overview

NovaTech Orion I/O Overview NovaTech Orion I/O 2 NOVATECH ORION I/O 3 NovaTech Orion I/O Overview NovaTech Orion I/O is an extension of the family of OrionLX Automation Platforms for substation automation and incorporates the same

More information

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists

Npefm!681F! !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! Model 570E Features. The Fiberoptic Communications Specialists !!!681F!Gjcfspqujd!Usbotdfjwfs! Gjcfspqujd!Ofuxpsl!Tpmvujpo!! The Fiberoptic Communications Specialists The Model 570E offers high-speed serial communication to meet the challenging needs of distribution

More information

EnGenius M SeriesM M2000 M5000 M36 M35

EnGenius M SeriesM M2000 M5000 M36 M35 EnGenius M SeriesM M2000 M5000 M36 M35 Outline EnGenius M Series Product Specification What is the MESH Network How can MESH do Advantages of MESH Network EnGenius NMS Tool Real Test Result Application

More information

Features. Intel 45nm Atom Processor N270: 1.6 GHz

Features. Intel 45nm Atom Processor N270: 1.6 GHz POC-C197 NEW Features 19" Slim Point-of-Care Terminal with Intel Atom Processor 19" LCD display with 16.7 M colors Intel Atom (ultra low-power) processor Fanless design with low audible noise Isolated

More information

Small hydro power plant automation. Oswaldo Kaschny Schneider Electric Brazil CDI Power

Small hydro power plant automation. Oswaldo Kaschny Schneider Electric Brazil CDI Power Small hydro power plant automation Oswaldo Kaschny Schneider Electric Brazil CDI Power Small Hydroelectric: Power and Control solution Operation Centre Turbine Measurement board Power meters And quality

More information

GS828. GPRS Data Logger

GS828. GPRS Data Logger Sirius Corp GPRS Data Logger Multi Channels Data Logging & Wireless Transmission Upload Data via GPRS and SMS on schedule or alarm triggered Programmable data logging and upload interval Support sensors

More information

NEW AMENDMENTS (2) TO ICT TENDER DOCUMENT

NEW AMENDMENTS (2) TO ICT TENDER DOCUMENT NEW AMENDMENTS (2) TO ICT TENDER DOCUMENT AMENDMENT TO SECTION VII Amended Technical Specifications of Computers and UPS for ICT in Schools. Servers : Server Configuration ( Intel Based) CPU: Processor

More information

Power Meter PowerMonitor 500

Power Meter PowerMonitor 500 ROCKWELL AUTOMATION PROCUREMENT SPECIFICATION PROCUREMENT SPECIFICATION PowerMonitor 500 NOTICE: The specification guidelines in this document are intended to aid in the specification of products. Specific

More information

IGAR G is a reliable IEEE a/b/g/n WLAN VPN router with 2 ports 10/100/1000Base-T(X) router where

IGAR G is a reliable IEEE a/b/g/n WLAN VPN router with 2 ports 10/100/1000Base-T(X) router where IGAR-1062+-4G Industrial IEEE 802.11 a/b/g/n 4G LTE Cellular Router with 2x10/100/1000Base-T(X) Features High Speed Air Connectivity: WLAN interface support up to 300Mbps link speed Provide 2 port 10/100/1000Base-T(X)

More information

Multifunction Transducer MT440

Multifunction Transducer MT440 Multifunction Transducer MT440 Voltage and current auto range measurements up to 600V, 12.5A Universal wide auxiliary power supply range 24 300 Vdc, 40 276 Vac Power accuracy class 0.5 (EN 60 688), Up

More information

InGateway 601 Intelligent Cellular Gateway

InGateway 601 Intelligent Cellular Gateway InGateway 601 Intelligent Cellular Gateway Cellular Routing, Text Message Alarms, Remote Secure Access InGateway 601 The InGateway 601 series, integrating 3G cellular routing, Modbus data acquisition,

More information

Special Provision No. 683S27 June 2017

Special Provision No. 683S27 June 2017 GATEWAY ROUTERS - Item No. Special Provision No. 683S27 June 2017 1. SCOPE This Special Provision covers the requirements for the installation of Gateway Routers with integrated digital subscriber line

More information

Note on. Alternative of BRI Connection For MAX-NG subscriber

Note on. Alternative of BRI Connection For MAX-NG subscriber Note on Alternative of BRI Connection For MAX-NG subscriber Released On : 12 th March 2012 CENTRE FOR DEVELOPMENT OF TELEMATICS MANDI ROAD, MEHRAULI, NEW DELHI 110030, INDIA ELECTRONICS CITY (PHASE I),

More information

OnCell G3150A-LTE Series

OnCell G3150A-LTE Series OnCell G3150A-LTE Series Rugged LTE serial/ethernet-to-cellular gateways Features and Benefits Dual cellular operator backup with dual-sim GuaranLink for reliable cellular connectivity Rugged hardware

More information

Bus Bar Protection Relay B-PRO 4000

Bus Bar Protection Relay B-PRO 4000 Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation

More information

Addendum & Corrigendum-1. Request for Proposal for Creation of OFC Network for BRTS Corridor and other important SMC Locations

Addendum & Corrigendum-1. Request for Proposal for Creation of OFC Network for BRTS Corridor and other important SMC Locations Addendum & Corrigendum-1 Request for Proposal for Creation of OFC Network for BRTS Corridor and other important SMC s Tender Number: SSCDL-ConnectedSurat-OFC-RFP-01-2018 Last date for Online Price Bid

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

Line Current Differential Protection Using Broadband Power Line Carrier Technology

Line Current Differential Protection Using Broadband Power Line Carrier Technology Line Current Differential Protection Using Broadband Power Line Carrier Technology Nachum Sadan CEO Amperion Inc. 2013 Utilities Telecom Council Delivering Your Future About Amperion Provider of advanced

More information

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2.

SIPROTEC 5 Application Note. Breaker-and-a-half solutions. SIP5-APN-002, Edition 2. -and-a-half solutions SIP5-APN-002, Edition 2 www.siemens.com/protection SIPROTEC 5 Application Note -and-a half solutions SIP5-APN-002, Edition 2 -and-a-half solution Content 1 -and-a-half solutions 3

More information

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features

PM174 PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER. Features PM174 IEEE1159 ADVANCED POWER QUALITY ANALYZER The PM174 is a compact, multi-function, three-phase AC powermeter and power quality analyzer specially designed to meet the requirements of users ranging

More information

CONTENTS... 2 COMTROLL SAS. SURVEILLANCE AND AUTOMATION SYSTEM...

CONTENTS... 2 COMTROLL SAS. SURVEILLANCE AND AUTOMATION SYSTEM... GENERAL INFORMATION Contents CONTENTS... 2 COMTROLL SAS. SURVEILLANCE AND AUTOMATION SYSTEM... 3 COMMUNICATION... 4 BUILDING-BLOCKS... 5 NETTROLL AND NETDRAW... 5 NETALERT... 6 NETGRAPH... 7 COMTROLL OUTSTATIONS...

More information

C) 11 KV SF6 Ring Main Units (RMUs)

C) 11 KV SF6 Ring Main Units (RMUs) C) 11 KV SF6 Ring Main Units (RMUs) 1.0 SCOPE: The specification covers site survey, engineering, manufacturing, pre dispatch testing, supply, and transportation, unloading at site complete erection, testing

More information

MODULAR CIRCUIT MONITORING SYSTEM

MODULAR CIRCUIT MONITORING SYSTEM MODULAR CIRCUIT MONITORING SYSTEM Contact Anord Mardix (USA) Inc. 3930 Technology Court Sandston, VA 23150 Email: us.sales@anordmardix.com Call: +1 800 228 4689 www.linkedin.com/company/anordmardix www.twitter.com/anordmardix

More information

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG

Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG Whiteacres, Whetstone, LeicesterLE8 LE8 6ZG www.oem.co.uk Contents Shunts Page 3-4 Digital Meters with Bargraph Page 5-6 Large Displays Page 6-7 Power Analyzers, Synchronizing Units Page 8 Recorders Page

More information

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

3G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway. SE5901B Series FEATURE HIGHLIGHTS PRODUCT DESCRIPTION Series G/4G LTE Cellular to Ethernet and Serial Secure Industrial Gateway FEATURE HIGHLIGHTS Extensive G and LTE Band Support - EU: 2100/1800/850/2600/900/800MHz (B1/B/B5/B7/B8/B20) - US: 1900/AWS/850/700/700/1900MHz

More information

National Electric Power Regulatory Authority NEPRA. Purchase of 01 UPS for Datacenter Servers and 19 UPSs for Individual s Desktop Computers

National Electric Power Regulatory Authority NEPRA. Purchase of 01 UPS for Datacenter Servers and 19 UPSs for Individual s Desktop Computers National Electric Power Regulatory Authority NEPRA Purchase of 01 UPS for Datacenter Servers and 19 UPSs for Individual s Desktop Computers NEPRA Bid No. 03/2015 Bid Serial No. Dated: Name of the firm

More information

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications

Multilin EPM Energy and Demand Submeter with Wi-Fi. Monitoring & Metering. Communications. Key Benefits. Applications Multilin EPM 6100 Energy and Demand Submeter with Wi-Fi The EPM 6100 is a powerful tool that allows customers to monitor and manage their energy usage within factories, businesses and across campuses.

More information

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics

SIA-C. Overcurrent and Earth Fault Protection Relay for Secondary Distribution. Dual & Self Powered. Main characteristics SIA-C Overcurrent and Earth Fault Protection Relay for Secondary Distribution Dual & Self Powered Main characteristics The SIA-C is a overcurrent protection relay with self powered and dual powered (self

More information

Hitachi s Smart Grid Solutions

Hitachi s Smart Grid Solutions Hitachi s Smart Grid Solutions Energy Efficiency Policies and Technologies in South Africa Workshop September 6 th, 2012 Shin-ichi INAGE Renewable Energy & Smart Grid Division, Power Systems Company, Hitachi

More information

SCADAPack 312E 313E. Smart RTUs for water

SCADAPack 312E 313E. Smart RTUs for water SCADAPack 312E 313E Smart RTUs for water 1 SCADAPack 312E and 313E Smart RTUs feature 32-bit processing, serial and US communications, integrated 12-30Vdc power supply, advanced power-management and a

More information

Power System Control And Smart Grid

Power System Control And Smart Grid Power System Control And Smart Grid The Technology Journey so far... 2005-07 2007-09 2009-11 2011-12 OMS Implementation ISO 27001- Security certification Basic DMS Application,SPM JGC DMS System & Distribution

More information

Example for a VISONIK system configuration:

Example for a VISONIK system configuration: 85P0 85P0 8 577 PLD0.TOWER PLD0.RACK VISONIK PLD0.TOWER DCS Data and Communication Server PLD0.RACK Data and communication servers (DCS) are used as management stations in building automation and control

More information

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test:

DRTS 3 PLUS. Advanced Protection Relay Test Set and Measurement System. DRTS 3 PLUS has been designed to test: Advanced Protection Relay Test Set and Measurement System Multi-tasking equipment designed for testing protection relays, energy meters, transducers Particularly designed to test RTU (remote terminal unit)

More information

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000

SICAM A8000 Series. Operation, telecontrol, and automation in the smallest spaces. siemens.com/sicam-a8000 SICAM A8000 Series Operation, telecontrol, and automation in the smallest spaces siemens.com/sicam-a8000 4 Applications 5 Scalability in the application 6 Highlights at a glance 8 The entire product family

More information

the easy solution for Smart Metering

the easy solution for Smart Metering EQUOBOX.SMART WIRELESS M-Bus SOLUTION_PP_1.1_en the easy solution for Smart Metering 1 EQUOBOX WHAT IT IS EQUOBOX is a system for metering energy and other resources in a building allowing the allocation

More information

Bridge: The 702-W will operate in Layer 2 without network segmentation. Router: The 702-W offers Layer 3 routing to allow network segmentation.

Bridge: The 702-W will operate in Layer 2 without network segmentation. Router: The 702-W offers Layer 3 routing to allow network segmentation. THE INDUSTRIAL NETWORK COMPANY 700 SERIES Industrial Wireless Radio 702-W The N-TRON 702-W Industrial Wireless Radio provides outstanding performance and extreme reliability under the harshest industrial

More information

Pre-Bid Queries for NIT No. RECPDCL/TECH/SERVER-GED/e-Tender/ /186 Dated:

Pre-Bid Queries for NIT No. RECPDCL/TECH/SERVER-GED/e-Tender/ /186 Dated: S. No. Vendor Item 1 HTPGT Pre Qualifying criteria 20/3 Page No. / Clause No. Parameter Sucessful Projects execution 2 HTPGT EMD 3 EMD Amount 3 4 Technical Specifications as per RFP Queries / Modifications

More information

IDM DATA ACQUISITION SYSTEM

IDM DATA ACQUISITION SYSTEM DATA ACQUISITION SYSTEM The a compact and economical multifunction data acquisition system Rendering all Unrivalled product profile Advanced multifunctional distributed data acquisition system Fully multitasking

More information

SICAM DC - A new Generation of Smart Meter Data Concentrator Answers for infrastructure and cities.

SICAM DC - A new Generation of Smart Meter Data Concentrator Answers for infrastructure and cities. Siemens Smart Grid Products - A new Generation of Smart Meter Data Concentrator Answers for infrastructure and cities. Smart Metering an integral Part of Smart Grids The Challenges. The Contribution of

More information

Generation Interconnection Impact Study Report. For. Interconnection Customer Q0022

Generation Interconnection Impact Study Report. For. Interconnection Customer Q0022 Generation Interconnection Impact Study Report For Interconnection Customer Q0022 Prepared by: PacifiCorp Date: 10/29/2003 Generation Interconnection System Impact Study Report Interconnection Customer

More information

APIC FortisAlberta s SCADA FAULT INDICATOR Project

APIC FortisAlberta s SCADA FAULT INDICATOR Project APIC 2017 FortisAlberta s SCADA FAULT INDICATOR Project Project requirements Project investigation Project evaluation Project integration Question period Who are we? Large Service Territory Wire Service

More information