Table Of Contents I. Precautions Before Using The Scale

Size: px
Start display at page:

Download "Table Of Contents I. Precautions Before Using The Scale"

Transcription

1 Table Of Contents I. Precautions Before Usin The Scale II. Explanation Of Display Symbols III. Keypad Functions IV. Operations (I)Switch on & off (II) Zero the scale (III) Samplin before countin (IV) Preset unit weiht in numeric keys (V) Subtract container s weiht (VI) Weiht/Quantity accumulation (VII) Preset countin check rane (VIII) Preset weiht check rane IV. User Prorammin Functions (I) Auto. shut off time span (II) Zero Trackin Rane (III) Zero display rane (IV) Stable class rane (V) Stable class rate (VI) Backliht type (VII) Chane unit of measure from k/ to Pound (VIII) Unit weiht recomputin (IX) Check alarm type (Ⅹ) Baud Rate settin (XI) Transmit method settin (XII) Label format settin (available when a label printer is connected.) (XIII) Cancel Tare settin VI. Calibration (can only be done in k) VII. Power supply & battery operation VIII. RS-232 Output IX. Error Codes Ⅹ. Technical Data

2 I. Precautions Before Usin The Scale Environment The scale should always be used in an environment, which is free from excessive air currents, corrosives, vibration, and temperature or humidity extremes. These factors will affect displayed weiht readin. DO NOT install the scale: Next to open windows or doors causin drafts or rapid temperature chanes. Near air conditionin or heatin vents. Near vibratin, rotatin or reciprocatin equipment. Near manetic fields or equipment that enerates manetic fields. On an unstable work surface In a dusty environment In direct sunliht. Levelin the Scale The scale is equipped with a level indicator on the left bottom side of the front panel and four adjustable levelin feet. Adjust the levelin feet until the bubble appears in the center circle of the indicator. Turn on Scale Do not turn on scale with anythin on the platform. When the scale is used with a power adapter, the switch located on the riht side of scale should be on. Then press the button ON/OFF to turn on the scale. When the scale is used with the battery only, press the key ON/OFF directly to turn on the scale. The scale will start to count down from nine to zero. The scale is then ready for use. Give a warm-up for 15~30 minutes before use. 1

3 II. Explanation Of Display Symbols PCS /PC Display Windows Weiht Display Totals 6 diits for weiht accumulated or bein measured on the pan. Unit Weiht Display Totals 6 diits for unit weiht or times of weiht accumulated. Count Display Totals 6 diits for number accumulated or bein counted on the pan. 2 1

4 Indicated Symbols Symbols Specification Scale is in TARE mode. Scale is in ZERO mode. Scale is in ACCUMULATION mode. The display readin is in STABLE condition. Lack of Sample Weiht If the total sample weiht on the pan is less than 10 display divisions, a trianular indicator will appear to remind the user to add more samples until the indicator disappears. Lack of Unit Weiht If the unit weiht is less than 1/10 display divisions, a trianular indicator will appear to remind the user that the displayed unit weiht is too small for ettin accurate quantity calculations. Low Voltae 3 1

5 III. Keypad Functions Keys Specification 0~9 Numeric keys Decimal point key C ZERO TARE SMPL U.WT ALARM ADD TOTAL P.TARE SET ENTER MOVE MEMORY ON/OFF Use this key to clear out the displayed numeric readins. If there is a minor weiht displayed without anythin on the pan, hit the zero key to clear the display. Use this key to subtract the container s weiht, indicates that the current weiht readin is net weiht. Use this key to input sample size. Use this key to input the known unit weiht of item to be counted. Use this key to input the HIGH & LOW weiht/quantity limit for check function. Use this key to accumulate weiht/quantity measured. Use this key to recall total weiht, count & accumulation times. Use this key to preset TARE weiht. Use this key to enter into User Prorammin Functions. Use this key to confirm the parameter settin. Use this key to move the parameter value in Set Mode. Use this key to memory a value to a location. On/Off switch. 4 1

6 IV. Operations (I) Switch on & off Click the on & off button to turn on or turn off the scale. (II) Zero the scale Press ZERO key to return the display to zero in case there is any zero driftin while unloaded. (III) Samplin before countin Unknown unit weiht 1. Place a few pieces of item to be counted on the pan. 0 PCS /PC Sample Weiht 2. Input the quantity of item on the pan. 40 PCS /PC Sample Weiht Input sample size 5 1

7 3. Press SMPL key Note: The system default is Unit Weiht. If the SMPL key is clicked when the value (ex.:40) in window is blinkin, then the numerical value input will be as Quantity. If the SMPL key is not clicked when the value (ex.:40) in window is blinkin, then the numerical value input will be as Unit Weiht PCS annP /PC Sample Weiht (SAMPLE) 4. The samplin operation is completed while stable display appears as below : 50 PCS /PC Sample Weiht Unit Weiht The larer sample size, the more accurate unit weiht Press SMPL key to recomputin unit weiht durin in countin process if the settin of Unit Weiht Recomputin set to on (Please refer to the section (VIII) of V. ). 6 1

8 Known unit weiht 1. Input the known unit weiht. 0 PCS /PC Known unit weiht 2. Press U.Wt key to complete samplin operation & enter into countin mode. Note: The system default is Unit Weiht. If the U.WT key is clicked when the value (ex.:0) in window is blinkin, then the numerical value input will be as Unit Weiht. 0 PCS /PC 7 1

9 (IV) Preset unit weiht in numeric keys How to store unit weiht in memory cells 1. Give a lon press of MEMORY to enter into Memory mode, and obtain unit weiht by inputtin the known value (ex.35) or by samplin operation mentioned before. Press the ENTER key to confirm the value. Note: Press the MOVE key chane the value when a wron value entered. 0 PCS U.W. Unit Weiht 35 /PC 2. Enter the tare value (ex. 10) and press the ENTER key to confirm the value. 0 PCS tare Tare 10 /PC 8 1

10 3. Enter the item number and press the ENTER key to confirm the value. Note: You can enter up to 6 diits. (For example: Item number ) 0 PCS Item. no Item Number /PC 4. Enter a address cell (1~100, total 100 cells available) by pressin any of the numeric keys (0~9), then press the ENTER key to store the unit weiht, tare value and item number into the address cell PCS Item Number WEIGHT Addr Address UNIT WEIGHT s--100 /PC Number 9 1

11 Note: 1) An error massae E4 will appear if the address code is out of 1~100. 2) When the address number has been used, the display will remind you if you want to update the memory. 0 PCS Updat e Update memo ry Memory Press the ENTER key to confirm, then the memory will be updated. Press the MOVE key to enter the new address. 0 PCS /PC ADDr Address Number /PC 10 1

12 How to recall the data stored Press the numeric key with stored data & keep pressin MEMERY key twice. You will see the unit weiht and tare on the display. 0 PCS Tare /PC 11 1 Unit weiht Note: 1) Place parts on the pan, you will know the number of parts. 2) Press the CLEAR key to clear the current Unit Weiht. 3) Press the U.WT key durin recall memory (Ex. address number 100) to check the item number addr Address PCS s /PC number Remark: When the Alarm Settin is set durin in the Recall Memory Mode, the Item Number and PLU Number can not be recalled.

13 (V) Subtract container s weiht weiht unknown 1. Place a container on the pan. 0 PCS /PC Container s weiht 2. Press TARE key PCS tare /PC 3.The scale will enter into countin mode while stable display appears as below. 0 PCS /PC 12 1

14 Container s weiht known 1. Nothin on the pan 0 PCS /PC Press P.TARE key PC Preta /P Input container s weiht known Input container s weiht pret a PCS /PC

15 Press P.TARE key PCS /PC 14 1

16 2. Scale is loaded 125 PCS WEIGHT UNIT WEIGHT Gross count /PC Gross weiht Unit weiht of item On the pan to be counted Press P.TARE key PC preta / Input container s weiht known 15 1

17 100 PCS PC preta / Press P.TARE key Net count WEIGHT UNIT WEIGHT /PC Net weiht on Unit weiht of item the pan to be counted Eliminate TARE Remove all on the pan & the weiht display will show a neative ( - ) container s weiht. Pressin TARE key at this moment will brin the weiht display to zero and TARE trianular indicator ( ) will disappear. 16 1

18 (VI) Weiht/Quantity accumulation 1. Place item to be weihed/counted on the pan. 5 PCS /PC Weiht on the pan 2. Press ADD key d 3. Display readins to be stable as below. ad PCS /PC 5 PCS WEIGHT UNIT WEIG HT Total accumulated count /PC Total accumulated weiht Total accumulation times Accumulation effective only when stays at zero. 17 1

19 4. Press TOTAL key or wait approx. 2 seconds, the scale will return to countin mode. 5 PCS WEIGHT Count UNIT WEIGHT /PC Weiht on the pan Unit weiht 5. Press TOTAL key to enter into accumulation status mode. At this moment, total accumulated weiht is shown In WEIGHT window, total accumulation times is shown in UNIT WEIGHT window and TOTAL PIECES window displays accumulated count. Press TOTAL key aain to revert to countin mode. Clear accumulation Press TOTAL key to enter into accumulation status mode and press CLEAR key to clear all accumulated data. 18 1

20 (VII) Preset countin check rane Users can set a Hi Lo rane for countin check, when the number of objects on the pan is within the preset countin check rane, the alarm will sound beeps repeatedly. Procedures 1. Press ALARM key while the scale is either loaded or unloaded. 0 PCS Low limit value to be input WEIGHT UNIT WEIGHT --H1-- 0 /PC Hih limit 2. Key in the desired hih limit value. Window for displayin hih limit value to be input (use CLEAR key to erase the value keyed in ) 0 PCS Low limit value to be input WEIGHT UNIT WEIGHT --H /PC Hih limit 19 1 Hih limit value keyed in

21 3. Press ALARM key aain and key in the desired low limit value as indicated below. (Low limit value effective only after hih limit is preset) 5 PCS Low limit value to be input WEIGHT --l0-- UNIT WEIGHT 2000 /PC Low limit Hih limit value keyed in 4. Press SMPL key to complete countin check rane preset procedure and return to normal countin mode. WEIG HT UNIT WEIGHT 0 PCS /PC Note: An error massae E5 appears When the LO value is set hiher than HI value. 20 1

22 (VIII) Preset weiht check rane Users can set a Hi Lo rane for weiht check when the weiht of objects on the pan is within the preset weiht check rane, the alarm will sound beeps repeatedly. Procedures 1. Press ALARM key while the scale is either loaded or unloaded. 0 PCS Low limit value to be input WEIGHT Hih limit --HI-- 2. Key in the desired hih limit value. UNIT WEIGHT Window for displayin hih limit value to be input (Use CLEAR key to erase the value keyed in) 0 /PC 0 PCS WEIGHT --HI-- Hih limit 21 1 Low limit value to be input UNIT WEIGHT /PC Hih limit value keyed in

23 3. Press ALARM key aain and key in the desired low limit value as indicated below. ( low limit value effective only after hih limit is preset ) PCS Low limit value to be input WEIGHT --lo-- Low limit UNIT WEIGHT /PC Hih limit value keyed in 4. Press U.Wt key to complete weiht check rane preset procedures and return to normal countin mode. 0 PCS WEIG HT UNIT WEIGHT /PC Note: An error massae E5 appears When the LO value is set hiher than HI value. Clear hih / low value preset Follow the above preset procedures and key in 0 or press CLEAR key directly for hih and low limit value. 22 1

24 V. User Prorammin Functions In countin mode, press SET key to enter into USER PROGRAMMING FUNCTION MODE. After pressin SET key, the display shows PASS WORD to prompt to key in a pass word , then press Enter key to confirm the pass word. If the pass word is wron, then the scale can not to enter into User Prorammin Function Mode. The display shows error to prompt the mistake when the pass word is wron. If wron pass word is entered for two times, then the scale will return to countin mode automatically. ( I ) Auto. shut off time span 1. When enter into User Prorammin Functions mode, the displays will indicate as below eventually PCS Internal count WEIGHT UNIT WEIGHT 0 a.off /PC Auto. shut off time Auto shut off span previously set 2. Press MOVE key to revolve the system-preset time span (2 min., 5 min., 8 min., and 0 ), 3. Press CLEAR key to determine and return to normal countin mode or press ENTER key for determination and move to next. Turn off the scale to return to normal countin mode. 23 1

25 ( II ) Zero Trackin Rane 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS Internal count WEIGHT UNIT WEIGHT 2 trac /PC Zero trackin rane (0~4) Zero trackin 2. Press MOVE key to revolve the system-preset zero trackin rane ( 0=off, 1=0.5d, 2=1d, 3=2d, 4=3d). The larer number selected, the wider rane. 3. Press CLEAR key to determine and return to normal countin mode or press ENTER key for determination and move to next. Turn off the scale to return to normal countin mode. 24 1

26 (III) Zero display rane 1. Keep pressin ENTER key in USER PROGRAMMIN FUNCTION MODE and release until the followin displays appear PCS Internal Count WEIGHT UNIT WEIGHT 2 ZEro /PC Zero display rane ( 0 ~ 4 ) Zero display 2. Press MOVE key to revolve the system-preset zero display rane ( 0=off, 1=0.5d, 2=1d, 3=2d, 4=3d ). The larer number selected, the wider rane. Press CLEAR key to determine and return to normal countin mode or press ENTER key for determination and move to next. Turn off the scale to return to normal countin mode. 25 1

27 (IV) Stable class rane 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS Internal count WEIGHT UNIT WEIGHT 2 FiLt /PC Stable class rane ( 0 ~ 5 ) Stable class 2. Press MOVE key to revolve the system-preset stable class rane ( 0=off, 1=0.05d, 2=0.15d, 3=0.25d, 4=0.35d, 5=0.45d ). The smaller number selected, the shorter time for display stability. 3. Press CLEAR key to determine and return to normal countin mode or press ENTER key for determination and move to next. Turn off the scale to return to normal countin mode. 26 1

28 (V) Stable class rate 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS Internal count WEIGHT UNIT WEIGHT 1 t.rate /PC Stable class rate (0~5) Stable class rate 2. Press MOVE key to revolve the system-preset zero return class rane ( level: 0, 1, 2, 3, 4, 5). The larer number selected, the more stable zero point. 3. Press CLEAR key to determine and return to normal countin mode or press ENTER key for determination and move to next. Turn off the scale to return to normal countin mode. 27 1

29 (VI) Backliht type 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS Internal count WEIGHT UNIT WEIGHT Backliht type 0 bl /PC Backliht 2. Press MOVE key to revolve the system-preset backliht type ( 0 auto. backliht, 1 manual backliht ) 3. Press CLEAR key to determine and return to normal countin mode or press ENTER key for determination and move to next. Auto. Backliht Backliht will be oin on automatically whenever the scale is loaded by objects weih reater than 9 display resolution or any of keys is pressed. And it will be oin off also automatically approx. 5 seconds after the scale returns to zero. Manual backliht Press (decimal point) key to switch on and off backliht. Scale will keep the backliht type selected in memory for next use. Turn off the scale to return to normal countin mode. 28 1

30 (VII) Chane unit of measure from k/ to Pound 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS Internal count WEIGHT UNIT WEIGHT 0 Unit /PC Units of measure Unit 2. Press MOVE key to revolve the system-preset units of measure. ( o k or, 1 lb ) 3. Press CLEAR key to determine and return to normal countin mode or press ETNER key for determination and move to next. Turn off the scale to return to normal countin mode. 29 1

31 (VIII) Unit weiht recomputin 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS WEIGHT Internal count UNIT WEIGHT Recomputin mode 0 au /PC Averain 2. Press MOVE key to revolve the system-preset recomputi mode. 0 disable recomputin function 1 enable recomputin function 3. Press CLEAR key to determine and return to normal countin mode or press ETNER key for determination and move to next. The unit weiht will be averaed aain if you add the remainin quantity, radually, by several lots. This will help eliminate errors caused by the possible weiht variation amon each object and lead to more accurate results. When addin objects to the pan (The weiht value should not be less than 10 display divisions.), be sure that the quantity is LESS THAN those already on the pan. The alarm will sound a beep when the unit weiht is averaed aain. Recomputin function effective only after samplin operation is done. Turn off the scale to return to normal countin mode. 30 1

32 (IX) Check alarm type 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS Internal count WEIGHT UNIT WEIGHT 0 PASS /PC check alarm type check alarm 2. Press MOVE key to revolve the system-preset check alarm types. 0 Inside type, 1 Outside type 3. Press CLEAR key to determine and return to normal countin mode or press ENTER key for determination and move to next. 31 1

33 Inside type The alarm sounds beeps only when either total weiht or total count falls inside the set rane. Ex. 1 Countin check alarms 100 PCS EX. 2 Weiht check alarms PASS- /PC 100 PCS PASS- /PC 32 1

34 Outside type The alarm sounds beeps only when either total weiht or total count falls outside the set rane. Ex. 1 Countin check alarms PCS Ex. 2 Weiht check alarms WEIG HT HI-- /PC 0 UNIT WEIGHT Over hih limit 10 --lo- - Below low limit Turn off the scale to return to normal countin mode. PCS /PC 33 1

35 (Ⅹ) Baud Rate settin 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS 0 rate /PC 2. Press MOVE key to revolve the system-preset baud rate. ( , , ) 3. Press ENTER key to determine and return to next settin. Turn off the scale to return to normal countin mode. 34 1

36 (XI) Transmit method settin 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS 1 trn /PC 2. Press MOVE key to revolve the system-preset transmit method. 1 = transmit by pressin a key 2 = series transmit 3 = transmit by pressin a key (for a label printer, such as: Model DLP-50 ) 4 = auto-transmit (for a label printer, such as: Model DLP-50 ) 3. Press ENTER key to determine and return to next settin. Turn off the scale to return to normal countin mode. 35 1

37 (XII) Label format settin (available when a label printer is connected.) 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS 0 forn /PC 2. Press MOVE key to revolve the system-preset file name of the format. (form0~9) 3. Press ENTER key to determine and return to next settin. Turn off the scale to return to normal countin mode. 36 1

38 (XIII) Cancel Tare settin 1. Keep pressin ENTER key in USER PROGRAMMING FUNCTION MODE and release until the followin displays appear PCS 1 tare /PC 2. Press MOVE key to revolve the system-preset Cancel Tare mode. 1 The tare can be canceled continuously. 2 The tare must be canceled for one time only.(note: If the canceled tare is not the value tared, then the buzzer will tweet to indicate the error. Turn off and turn on the solve the error.) 3. Press ENTER key to determine and return to normal countin mode. Turn off the scale to return to normal countin mode. 37 1

39 VI. Calibration (can be done in k/ib) 1. Turn on the scale, and key in durin countin down (self-check) to zero to enter into Simple Calibration mode. The displays will indicate as below eventually. (Take 6k scale for instance) CAL PCS /PC Required weiht (6 k) for calibration 2. Put a weiht on the pan same as what exactly shown in the UNITWEIGHT window, then press the ENTER key to confirm the operation. The displayed readin in the UNIT WEIGHT window starts blinkin. The scale will stop blinkin and return to normal countin mode. Calibration is now completed. Required weiht for calibration can be chaned by usin numeric keys before step 2 above. Press CLEAR key to escape from calibration mode at any time. 38 1

40 VII. Power supply & battery operation POWER SUPPLY AC Adaptor DC 12V/800mA or 12V/1000 ma BATTERY OPERATION The scale can be operated from the battery if desired. The battery life is approximately 80 hours. When the battery needs charin a symbol on the display will turn on. The scale can keep operatin for about 10 hours when the symbol appears. The scale will automatically switch off to protect the battery. Before switchin off automatically, a prompt words Lobat off will be shown three times to indicate the scale switch off due to battery empty. To chare the battery, connect the power adapter, and turn on the switch on the riht side of the scale. The battery should be chared for 12 hours for full capacity. There is an LED to indicate the status of battery charin on the display. If the LED is Green the battery has been chared. If it is Red the battery is nearly dischared and Yellow indicates the battery is increasin the chare level. As the battery is used it may fail to hold a full chare. If the battery life becomes unacceptable then contact your distributor. Note: The battery should be rechared every 3 months if the scale is not used for lon time. 39 1

41 VIII.RS-232 Output The scale can be ordered with as optional RS-232 output. 1. Mode E1A-RS 232C s UART sinal 2. Format: Baud rate: 9600 BPS Data bits: 8 BITS Stop bit: 1 BIT Code ASCll Connector:9 Pin Socket Pin2 Input Pin3 Output Pin5 Sinal Ground 3. Data Format of Series transmit: Net=Net Weiht Pcs=Quantity U/W=Unit Weiht Tare= Tare 4. Transmit Format, when it is in Accumulation model and transmit by pressin ADD key and TOTAL key. Press the ADD key [100] No Record#01 Net: U/W: Pcs: 200 Tare:

42 Press the ADD key aain [100] No Record#02 Net: U/W: Pcs: 300 Tare: 35 Press the TOTAL key [100] No Total Net: U/W: Pcs: 500 Tare: 35 Note: When it is in normal countin model (without accumulation operation), press the TOTAL key to print the data, the transmit format is as below: [100] No Total Net: U/W: Pcs: 500 Tare::

43 5. Format of Automatic and Series transmit without accumulation: [100] No Total Net: U/W: Pcs: 500 Tare: 35 Scale (E C ) Printer T YPE (DL P- 50) Rx Tx GND Rx Tx GND FEMALE MALE Connect EC and Printer usin same cable. [female(ec) male(dlp-50)] 42 1

44 6. Variables (The prompt character) used in scale also in label printer Variable Name Specifications Size SER Accumulated times (Weiht) 2 byte NWA Net weiht 7 byte NWB Net weiht(no dot) 6 byte TWA Tare weiht 7 byte TWB Tare weiht (no dot) 6 byte GWA Gross weiht 7 byte GWB Gross weiht (no dot) 6 byte TNA Total net weiht 7 byte TNB Total net weiht(no dot) 6 byte UWA Unit weiht 7 byte UWB Unit weiht (no dot) 6 byte QUA Quantity 7 byte QUB Quantity (no dot) 6 byte TQA Total Quantity 7 byte TQB Total Quantity (no dot) 6 byte UNT Weihin Unit 2 byte AN Address number 3 byte IN Item number 6 byte Note: 1) Capital Letters are allowed for the Variable Name only. 2) A value 0 will be iven when the value exceeds the display rane. 43 1

45 IX.Error Codes Durin the initial power-on testin it is possible the scale may show error messae. The meanin of the error messaes is described below. ERROR CODE POSSIBLE CAUSES HANDLING E1,E2,E3 1.The scale pan is placed Place the scale pan incorrectly. correctly. 2.Turn on scale with Take away the somethin on the scale pan. oods, and switch on aain. E4 Address code of Unit Weiht Correct the is out of 1~200. operation. E5 In alarm settin, the LO value Correct the is set hiher than HI value. operation. OL Overload Take off the weiht immediately. If the error messae still is shown after above ways, please recalibrate. If the problem still can not be solved then contact your dealer for further support. 44 1

46 X. Technical Data Capacity() Readability(e=d) Hih Low External Hih 1/30,000 Resolution Low 1/15,000 1/12,000 1/15,000 1/15,000 Internal Resolution 1/600,000 Display Type LCD Weiht Units k or, lb Zero Rane ±2% Tare Rane Full Capacity by Subtraction Stabilization Time 2 seconds Operation Temperature 0 ~ 40 Humidity Rane 90% relative humidity, non-condensin Power AC Adaptor DC 12V/1A or 12V/800mA Internal rechareable sealed acid battery Battery Life 80 hours continuous use with 12 hour rechare time Calibration Automatic external with k/ mass, factory calibration recovery Safe Overload Capacity 120% of capacity Product weiht 4.5k Dimension(mm) 360(W) x 360(D) x 106(H) Platter Size(mm) 304(W) x 220(D) 45 1

Bright Advance Corporation USER INSTRUCTIONS

Bright Advance Corporation USER INSTRUCTIONS Briht Advance Corporation USER INSTRUCTIONS Weihin Scale Briht Advance Corporation TABLE OF CONTENTS BEFORE USING THE SCALE2 PREPARING TO USE THE SCALE2 LCD DISPLAY3 KEYBOARD FUNCTION4 OPERATION5 1 DISPLAY

More information

CONTENTS. 7. User Programming Functions... 26

CONTENTS. 7. User Programming Functions... 26 2 CONTENTS 1. Precautions Before Using The Scale... 5 2. Overall view... 8 3. Installation... 9 4. Explanation Of Display Symbols... 11 5. Keypad Functions... 13 6. Operations... 14 A.Switch on / off...

More information

Service Manual for EC-II counting scale

Service Manual for EC-II counting scale Service Manual for EC-II countin scale Ⅰ. Phenomena of trouble 1) Trouble of part The trouble phenomena are as followin: a) Buzzer-----buzzer doesn t make sound, or sometimes make sound and sometimes doesn

More information

CONTENTS. PRECAUTIONS Introduction Installation... 7

CONTENTS. PRECAUTIONS Introduction Installation... 7 2 CONTENTS PRECAUTIONS... 4 1. Introduction... 6 2. Installation... 7 2.1 Unpacking... 7 2.2 Illustration of the installation for plastic shied... 7 2.3 Selecting the location... 8 2.4 Leveling the scale...

More information

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved. Kilotech KRS SWP Series Counter-top weighing scale NTEP (USA) and Measurement Canada approved www.kilotech.com KILOTECH KRS SWP series Weighing Scale NOTE: Le manuel en Français est disponible au www.kilotech.com.

More information

MWP SERIES. High Precision

MWP SERIES. High Precision MWP SERIES High Precision 1. INTRODUCTION------------------------------------------------1 2. INSTALLATION---------------------------------------------------2 2.1 Unpacking---------------------------------------------------------------

More information

KW serial. User s guide. Bench Scales UGKW-E0302

KW serial. User s guide. Bench Scales UGKW-E0302 KW serial Bench Scales User s guide UGKW-E0302 KW serial bench scale user s manual Table of Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS.. 2 SECTION 3 INSTALLATION.3 SECTION 4 KEY DESCRIPTIONS

More information

9. FUNCTION MENU SETTINGS -TION FUNCTION DESCRIPTION DEFAULT. VALUE F0 H-L SEt Lo Set a value for the Low

9. FUNCTION MENU SETTINGS -TION FUNCTION DESCRIPTION DEFAULT. VALUE F0 H-L SEt Lo Set a value for the Low ROW Weighing Scale CONTENTS 1. INTRODUCTION 1 2. KEY DESCRIPTIONS 1 3. BASIC OPERATION.. 2 3.1 Zeroing the display..2 3.2 Taring. 2 4. CHECK-WEIGHING..3 4.1 About check-weighing 3 4.2 Set limits 4 4.3

More information

IDS-801 Series Compact Bench Counting Scale. User Manual

IDS-801 Series Compact Bench Counting Scale. User Manual IDS-801 Series Compact Bench Counting Scale User Manual 1. INTRODUCTION... 3 1.1. Product Description... 3 1.2. General Features... 3 1.3. Safety Precautions... 3 2. INSTALLATION... 4 2.1. Unpacking...

More information

Trade Approved Version NMI: S520

Trade Approved Version NMI: S520 @Weigh BW/BWS Series Trade Approved Version NMI: S520 Weighing Indicator User s guide UGBW-E1.09 Table of Contents SECTION 1 INTRODUCTION. 1 SECTION 2 SPECIFICATIONS... 2 SECTION 3 INSTALLATION.3 3. 1

More information

EHC-WF. User/Technical Manual. Contents subject to change without notice

EHC-WF. User/Technical Manual. Contents subject to change without notice EHC-WF User/Technical Manual Contents subject to change without notice Version 1.0 7/2017 TABLE OF CONTENTS 1. INTRODUCTION... 1 General and Safety Information... 1 Specifications... 1 2. Unpacking and

More information

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6 Contents: 1. Introduction Page 2 Specifications Page 2 2. Installation Page 3 3. Key Functions Page 4 4. Operations Page 6 Check Weighing Page 6 Accumulation Page 7 Parts Counting Page 7 Print (RS232C)

More information

MC Piece Counting Scale

MC Piece Counting Scale MC Piece Counting Scale User Manual Contents 1. Precautions 3 2. Installation.. 4 3. Name and functions. 6 Key board... 6 Display 8 4. Operation... 9 Power ON/OFF.9 Zero. 9 Tare. 9 5. Parts Counting...10

More information

EB300 Weighing Scale Operation Manual

EB300 Weighing Scale Operation Manual EB300 Weighing Scale Operation Manual EB300 User Manual Page 1 of 18 TABLE OF CONTENTS 1. Safety Warnings... 3 2. Features..... 3 3. Options.......... 4 4. Product packaging.. 4 5. Display and keyboard.....

More information

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual Version 2.1 Gamma Scale Tel: (905) 455-8333 Fax: (905) 455-0658 E-mail: info@gammascale.com Website: www.gammascale.com 1. Technical Parameters

More information

Oxford E Series. Instruction Manual

Oxford E Series. Instruction Manual Oxford E Series Instruction Manual E Series User Manual Contents. Introduction................................................................... Unpacking...................................................................

More information

uline.com OVERVIEW OF CONTROLS CONTROL PANEL CONTROL PANEL PARTS

uline.com OVERVIEW OF CONTROLS CONTROL PANEL CONTROL PANEL PARTS π H-5276, H-5277 H-5278, H-5279 OHAUS ADVENTURER BALANCE SCALE 1-800-295-5510 uline.com OVERVIEW OF CONTROLS CONTROL PANEL CONTROL PANEL PARTS Dynamic Weihin Max 4201 d=0.01 e=0.01 # DESCRIPTION Tare Place

More information

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT c DWP-98 Series Counting scale User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT Specifications subject to change without prior notice CONTENTS 1. INSTALLATION

More information

MI101 / MI102 / MI102S INDICATOR

MI101 / MI102 / MI102S INDICATOR MI101 / MI102 / MI102S INDICATOR USER GUIDE Preface Thank you for purchasing the MI series indicator from Millennium Mechatronics Limited, New Zealand. The MI101/MI102 Indicator is an accurate, fast and

More information

TRWS series. Waterproof indicator User s guide UGTRWS-E1.1

TRWS series. Waterproof indicator User s guide UGTRWS-E1.1 TRWS series Waterproof indicator User s guide UGTRWS-E1.1 Table of Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS.. 2 SECTION 3 INSTALLATION.3 SECTION 4 KEY DESCRIPTIONS 5 SECTION 5 DISPLAYS.6

More information

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1.

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1. Userʼs Guide 1200g High Precision Scale Legal for Trade 1200g High Precision Scale Includes RS-232 interface port UG Version 1.2_12-30-13 !!!! CALIBRATION WARNING!!!! Calibration AND inspection of calibration

More information

CONTENTS PRECAUTIONS... 3 INSTALLATION... 4 ZERO... 9 TARE PRE-TARE AUTO TARE SELECTION OF WEIGHING UNIT... 16

CONTENTS PRECAUTIONS... 3 INSTALLATION... 4 ZERO... 9 TARE PRE-TARE AUTO TARE SELECTION OF WEIGHING UNIT... 16 CONTENTS PRECAUTIONS... 3 INSTALLATION... 4 FUNCTIONS ZERO... 9 TARE... 10 PRE-TARE... 12 AUTO TARE... 14 SELECTION OF WEIGHING UNIT... 16 UNIT IN USE AND INITIAL WEIGHING UNIT SETTING... 17 ACCUMULATION......19

More information

Multi-Function Smart Indicator User Manual

Multi-Function Smart Indicator User Manual Multi-Function Smart Indicator User Manual EC30006 Content 1 Notice... 2 2 Specification... 2 3 Main parameter... 3 4 How to fix... 3 5 Port... 4 6 On/Off... 4 7 Charging... 4 8 Display... 5 9 Screen keypad...

More information

SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual

SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual www.scintex.com.au sales@scintex.com.au SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual Technical Data Working Temperature:-5 to 35 C Storage Temperature:-25 to 50 C Stainless Steel Casing:

More information

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual MPB SERIES Electronic Balances r1 v1.09 Operation Manual CONTENT 1. Introduction 1 2. Key and display 2.1 Key Function 1 2.2 Display 1 3. Operation 3.1 Before use 2 3.2 Zeroing the display 2 3.3 Taring

More information

PCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13, Southpoint Business Park Suite 8 Ensign Way Jupiter, FL 33458 Hampshire / Southampton USA United Kingdom, SO31 4RF Phone: 561-320-9162

More information

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide DWP-PC SERIES PRICE COMPUTING SCALE User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT Specifications subject to change without prior notice CONTENTS 1. INSTALLATION

More information

BW/BWS Weighing Indicator

BW/BWS Weighing Indicator BW/BWS Weighing Indicator - 1 - CONTENTS 1. SPECIFICATION... 2 2. INTRODUCTION... 3 3. INSTALLATION. 4 Precautions 4 Parts 4 Installation.. 5 4. KEYS DESCRIPTION... 6 Key Board... 6 Secondary functions

More information

PS-C60K-D. Counting Scale Service Manual

PS-C60K-D. Counting Scale Service Manual PS-C60K-D Counting Scale Service Manual CONTENTS 1. PRECAUTIONS..4 2. INSTALLATION........ 5 3. NAME AND FUNCTIONS. 7 Key board...7 Display 8 4. OPERATION. 9 Power On/Off. 9 Switch to local / Remote Scale.....9

More information

TWP series. Weighing Indicator Service Manual

TWP series. Weighing Indicator Service Manual TWP series Weighing Indicator Service Manual CONTENTS 1. SPECIFICATIONS....3 2. INSTALATION AND PRECAUTIONS..4 Load cell connection......4 Power operation..5 Battery operation.5 3. NAME AND FUNCTIONS........6

More information

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION UWE-1707 SERIES CONTENTS ELECTRONIC WEIGHING INDICATOR OPERATION MANUAL 1. SPECIFICATIONS PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE 2. INSTALLATION 3. ROUTINE OPERATION

More information

Counting Scale. HC-3Ki. HC-15Ki HC-6Ki WM+PD

Counting Scale. HC-3Ki. HC-15Ki HC-6Ki WM+PD Counting Scale HC-30Ki HC-15Ki HC-6Ki HC-3Ki WM+PD41164 This manual and Marks All safety messages are identified by the following, WARNING or CAUTION, of ANSI Z535.4 (American National Standard Institute:

More information

NB/NHB Precision Balance

NB/NHB Precision Balance NB/NHB Precision Balance S 232: RS-232 USB; USB 6. WEIGHING UNIT LISTING Unit mark Unit name Conversion(g) 1 g gram 2 g gram (hi resolution) 3 ct net carat =0.2g 4 lb lb =453.59237g 5 oz ounce =28.349523125g

More information

TWP-W. Weighing Indicator Service Manual

TWP-W. Weighing Indicator Service Manual TWP-W Weighing Indicator Service Manual CONTENTS 1. SPECIFICATIONS....3 2. INSTALATION AND PRECAUTIONS..4 Load cell connection......4 Power operation..5 Battery operation.5 3. NAME AND FUNCTIONS........6

More information

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 KEYPAD AND DISPLAY 3.0 OPERATION 4.0 SETTING OPERATION 5.0 ERROR INFORMATION AND SPECIFICTION 6.0 ASSEMBLE INSTRUCTION 7.0 DEALER S SETTING 1.0 CAUTIONS AND PREPARATION

More information

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series Laboratory Balances Table of Contents Cautionary Notes and Precautions...3 1. Specification... 4 2. Keys and Display Indicators... 6 3. Commands and abbreviations...7 4. Parts Description...8 5. Unpacking

More information

Weighing Indicator M701. Handrail scales. REV: M1, April,05,2014 (v )

Weighing Indicator M701. Handrail scales. REV: M1, April,05,2014 (v ) Weighing Indicator M701 Handrail scales REV: M1, April,05,2014 (v3.09-3.014) CONTENTS 1. PRECAUTIONS..2 2. INTRODUCTION 3 3. SPECIFICATIONS...4 3.1Specifications...4 3.2 Load Cell Specification......5

More information

WUNDER SA.BI.SRL EN USER MANUAL. MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual

WUNDER SA.BI.SRL EN USER MANUAL.   MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual www.wunder.it MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED User Manual Read this manual carefully before using the instrument W100 SCALE W100 INDICATOR INDICE 2. BEFORE USING PAG. 2 3. SPECIFICATIONS

More information

BW/BWS/VW/CW/NTW/NSW. Weighing Indicator

BW/BWS/VW/CW/NTW/NSW. Weighing Indicator BW/BWS/VW/CW/NTW/NSW Weighing Indicator battery will be charged. If the LED is green the battery has a full charge. If it is Red the battery is nearly discharged. As the battery is used it may fail to

More information

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4. Table of Contents 1. Introduction 1 2. Precaution... 1 3. Product Introduction 3-1 Specifications & Features... 3-2 Front Panel 3-2-1 Display 3-2-2 Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4. Installation

More information

Analytical balance KERN ABS-N ABJ-NM

Analytical balance KERN ABS-N ABJ-NM Analytical balance ABS-N ABJ-NM Sinle-cell advanced technoloy: Fully automatically manufactured weihin cell from one piece of material Stable temperature behaviour Short stabilisation time: 3 sec Improved

More information

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale NORmal USE Buttons ON/OFF hold UNIT ZERO/TaRE Indicators FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale Starts and turns off scale hold-funktion holds the value up to 2 minutes. Switches between units

More information

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved Installation / Operator / Service Manual Bench Scales 2005-2010 by Fairbanks Scales Inc. All rights reserved 50778 Revision 6 07/10 Amendment Record 50778 Manufactured by Fairbanks Scales Inc. 821 Locust

More information

User Operation Manual

User Operation Manual This document hosted by: www.oldwillknottscales.com A Higher Level of Precision A Higher Level of Performance Intell-Count Dual Channel Counting Scale IDC Series User Operation Manual - 2 - January 2009

More information

BENCH SCALES FAST COMPETENT RELIABLE DIVERSE. GB KERN Professional measuring.

BENCH SCALES FAST COMPETENT RELIABLE DIVERSE. GB KERN Professional measuring. s A Z Independent and family-run, is already in its th eneration and is synonymous ECB/ECE...4 FCB... FCB-B/FCB-BM...8 FCE... FKB-A...9 FKB... FKT.../ FTB... GAB-N...7 Printed in Germany cb-b-nn- TRADITION

More information

INTRODUCTION INSTALLATION

INTRODUCTION INSTALLATION INTRODUCTION SNUG II precision balance series contains five models ---- SNUG II -150,300, 600, 1500 and 3000 with weighing capacities of 150g, 300g, 600g, 1500g and 3000g respectively. The display resolution

More information

Counting Scales. HC-i Series

Counting Scales. HC-i Series Counting Scales HC-i Series HC-i Simple Operation Mode By setting only the keys necessary for your operation, you can avoid making any unwanted operational mistakes. This mode is available for zero setting,

More information

Weighing Indicator Service Manual V1.24X

Weighing Indicator Service Manual V1.24X Weighing Indicator Service Manual V1.24X CONTENTS 1. PRECAUTIONS.3 2. SPECIFICATIONS....4 3. INTRODUCTION....5 4. INSTALLATION..6 Unpacking 6 Installation 6 Load cell connections......7 Connect Adaptor

More information

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED D-500s Indicator D - 500 LED User Instructions English 8921-004210 Issue September 2010 1 2-2 0 1 0 D 6 0 0 4 6 7 5 Page 2 D-500s Indicator Page 2 Table of Content Section 1: Introduction. 1.1 Introduction

More information

EC100. Counting Scale. Operations Manual (V1611)

EC100. Counting Scale. Operations Manual (V1611) EC100 Counting Scale Operations Manual (V1611) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com Fax: +1 866 612 9088 North America Toll Free: 1-855-ANYLOAD (269 5623) TABLE OF

More information

KCS Counting Scale Instruction Manual

KCS Counting Scale Instruction Manual KCS Counting Scale Instruction Manual Thank you for purchasing Model KCS Counting Scale. Please read all operating instructions carefully before using and note the following points: Avoid lengthy exposure

More information

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4. American Weigh Scales H-110 User Manual H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.0 H-110 Thank you for purchasing the H-110 digital hanging scale. Please

More information

CAUTIONS... 4 INTRODUCTION...

CAUTIONS... 4 INTRODUCTION... CONTENTS CAUTIONS... 4 INTRODUCTION... 6 FEATURES & MAIN FUNCTIONS... 6 SPECCIFICATION... 7 PART NAME & KEY FUNCTION... 8 SYSTEM MODE...11 GENERAL FUNCTION & DESCRIPTION... 16 CONVERSION MODE... 18 PRINT

More information

AELP PALLET BEAMS SCALES

AELP PALLET BEAMS SCALES Adam Equipment AELP PALLET BEAMS SCALES (P.N. 4327, Rev. A7, Mar 2016) Adam Equipment Company 2016 Adam Equipment Company 2016 CONTENTS 1.0 INTRODUCTION... 2 2.0 TECHNICAL SPECIFICATIONS... 3 3.0 UNPACKING

More information

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050 Weighing Indicator USER S GUIDE 0713 11 Harbor Park Drive Port Washington, NY 11050 Table of Contents I Main Specifications.............................3 II Display and Keyboard..........................4

More information

PRECAUTIONS... 4 PREFACE... 6 NAMES AND FUNCTIONS... 6 OPERATIONS... 8

PRECAUTIONS... 4 PREFACE... 6 NAMES AND FUNCTIONS... 6 OPERATIONS... 8 2 CONTENTS PRECAUTIONS... 4 PREFACE... 6 NAMES AND FUNCTIONS... 6 OPERATIONS... 8 General Weighing... 8 Weighing with Tare... 10 Counting Mode... 10 % Mode... 12 Set Mode... 13 RS232C INTERFACE... 20 ERROR

More information

Totalcomp TLI Indicator. Operation and Maintenance Manual Manual

Totalcomp TLI Indicator. Operation and Maintenance Manual Manual Totalcomp TLI Indicator Operation and Maintenance Manual Manual V1.08-0.06E DT: 04/29/2013 - - CONTENTS Precautions... 2 1. SPECIFICATIONS... 3 2. INTRODUCTION. 4 3. INSTALLATION... 5 Unpacking 5 Parts

More information

BBA-Series Precision Balances

BBA-Series Precision Balances Schematic BBA-Series Precision Balances BBA-600/BBA-1200 Service Manual 11 Schematic 1 10 Troubleshooting You have purchased a quality precision weighing instrument that requires handling with care. Trouble

More information

PS-IN202 Weighing Indicator User Manual

PS-IN202 Weighing Indicator User Manual PS-IN202 Weighing Indicator User Manual Version 2015.05 Contents FRONT AND REAR VIEW OF THE INDICATOR CHAPTER 1 CONNECTIONS 1.1 WHAT'S IN THE BOX 1.2 CONNECTING TO THE WEIGH PLATFORM 1.3 CONNECTION TO

More information

Compact Balances. EK-610j EK-6100j. in an Authorized A&D Dealer

Compact Balances. EK-610j EK-6100j.   in an Authorized A&D Dealer Compact Balances EK-610j EK-6100j 1WMPD4001387 This manual and Marks All safety messages are identified by the following, WARNING or CAUTION, of ANSI Z535.4 (American National Standard Institute: Product

More information

Multi-Function Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT

Multi-Function Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT 19eA & 19eS Multi-Function Indicator Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT Specifications subject to change without prior notice V110 Rev

More information

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5 CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5 COUNT VALUE DISPLAY 6 WEIGHING UNIT SETUP 7 INITIAL UNIT SETUP 7 AUTOMATIC

More information

OMEGA SERIES COUNTING SCALE

OMEGA SERIES COUNTING SCALE Operator Manual OMEGA SERIES COUNTING SCALE 2011-2018 by Fairbanks Scales, Inc. All rights reserved 51278 Revision 5 02/2018 Disclaimer Every effort has been made to provide complete and accurate information

More information

DL Series NEWDOLBO OWNER S MANUAL. Simple Weighing Scale 9002-DL

DL Series NEWDOLBO OWNER S MANUAL. Simple Weighing Scale 9002-DL Simple Weighing Scale DL Series NEWDOLBO OWNER S MANUAL 9002-DL1-0033-0 2005. 9 CONTENTS PRECAUTIONS 4 PREFACE 6 NAMES AND FUNCTIONS 6 INSTALLATIONS 8 OPERATIONS 9 1. General Weighing 9 2. Weighing with

More information

I. PANEL DESCRIPTION... 1

I. PANEL DESCRIPTION... 1 Table of Contents I. PANEL DESCRIPTION... 1 II. OPERATING INSTRUCTION... 7 1. MA OUTPUT... 7 1A. GENERAL OPERATION 4-20MA... 7 1B. SELECT 0-20MA OR 0-24MA... 8 1C. ENTER A VALUE LESS THAN 1... 9 2. % (PERCENTAGE)

More information

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance. 1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance. 1.1 Safety Precautions Please follow these safety

More information

DMC-688. When Accuracy Counts

DMC-688. When Accuracy Counts DMC-688 Money Counti ng Scal e When Accuracy Counts Operation Manual 73360 DMC- 688 SERIES OPERATING MANUAL SECTION INDEX PAGE NUMBER 1.0. GENERAL 1.1. Unlocking Procedure 1.2. Setting Up 2 3 2.0. SPECIFICATIONS

More information

Operating instructions METTLER TOLEDO BD balances

Operating instructions METTLER TOLEDO BD balances Operating instructions METTLER TOLEDO BD balances 0.00 g Startup procedure 1 Unpacking, standard equipment The standard equipment contains: BD balance, Weighing pan, permanently mounted with BD6000, AC

More information

IQ6200/6500 Counting Scales. Installation Manual

IQ6200/6500 Counting Scales. Installation Manual IQ6200/6500 Counting Scales Installation Manual 32224 Contents About this Manual... 1 1.0 Introduction... 1 1.1 Scale Resolution... 2 1.2 Choosing the Best Sample... 2 2.0 Installation and Start-Up...

More information

CONTENTS. PRECAUTIONS 4 PREFACE 6 NAMES AND FUNCTIONS 6 OPERATIONS 8 General Weighing 8 Weighing with Tare 10 Counting Mode 10 % Mode 12 Setup Mode 13

CONTENTS. PRECAUTIONS 4 PREFACE 6 NAMES AND FUNCTIONS 6 OPERATIONS 8 General Weighing 8 Weighing with Tare 10 Counting Mode 10 % Mode 12 Setup Mode 13 CONTENTS PRECAUTIONS 4 PREFACE 6 NAMES AND FUNCTIONS 6 OPERATIONS 8 General Weighing 8 Weighing with Tare 10 Counting Mode 10 % Mode 12 Setup Mode 13 RS 232C INTERFACE 20 ERROR MESSAGE 21 SPECIFICATION

More information

PRW series. Bench Scale. User s guide UGPRW-E1.01

PRW series. Bench Scale. User s guide UGPRW-E1.01 PRW series Bench Scale User s guide UGPRW-E1.01 Table of Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS.. 2 SECTION 3 INSTALLATION.3 SECTION 4 KEY DESCRIPTIONS 5 SECTION 5 DISPLAYS.6 SECTION

More information

BW/BWS/CW/VW series. Bench Scales User s guide UGBW/BWS/C W/VW-E1.17

BW/BWS/CW/VW series. Bench Scales User s guide UGBW/BWS/C W/VW-E1.17 BW/BWS/CW/VW series Bench Scales User s guide UGBW/BWS/C W/VW-E1.17 Table of Contents SECTION 1 INTRODUCTION. 1 SECTION 2 SPECIFICATIONS... 2 SECTION 3 INSTALLATION.3 3. 1 General installation. 3 3. 2

More information

SAC / SHC / SHC-CH SERIES

SAC / SHC / SHC-CH SERIES This document hosted by: www.oldwillknottscales.com SAC / SHC / SHC-CH SERIES HIGH PRECISION COUNTING SCALE OPERATION MANUAL PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE July

More information

PW-II Service Manual PW-II SERVICE MANUAL

PW-II Service Manual PW-II SERVICE MANUAL PW-II Service Manual PW-II SERVICE MANUAL 1 9/2/2011 PW-II Service Manual < Table of Contents > 1. Introduction... 3 1.1. Preface... 3 1.2. Precaution... 3 1.3. Specifications... 4 1.4. Key... 5 1.5. Sealing

More information

Model 500 Digital Weight Indicator

Model 500 Digital Weight Indicator Rev. 1.10 Serial Number: Model 500 Digital Weight Indicator USER MANUAL 1992-2000, Reliable Scale Corporation Reliable Scale Corporation 520 Moraine Road NE Calgary, Alberta, Canada Tel:1-800-419-1189

More information

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows: Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows: Click On Start Pick Program Weighing Indicator USER S GUIDE Pick Accessories Pick Communications Pick Hyper

More information

! User Manual Rev. 1

! User Manual Rev. 1 User Manual Rev. 1 Warnings For safety operation of the weighing indicator, please follow the following warning/ safety instructions: Calibration inspection and maintenance of the indicator are prohibited

More information

This document courtesy of:

This document courtesy of: This document courtesy of: Data Weighing Systems, Inc. Contact Us For immediate assistance call 1-800-750-6842 Introduction Thank you for purchasing a Setra Super Count scale. Its ease of operation and

More information

Counting Scale. FC-500Si. FC-50Ki FC-20Ki FC-10Ki. FC-500i. FC-2000i FC-1000i WM+PD B

Counting Scale. FC-500Si. FC-50Ki FC-20Ki FC-10Ki. FC-500i. FC-2000i FC-1000i WM+PD B Counting Scale FC-50Ki FC-20Ki FC-10Ki FC-5000i FC-2000i FC-1000i FC-500i FC-5000Si FC-500Si WM+PD4000541B This manual and Marks All safety messages are identified by the following, WARNING or CAUTION,

More information

Instruction Manual for. Torbal AGZN Series Balances

Instruction Manual for. Torbal AGZN Series Balances Instruction Manual for Torbal AGZN Series Balances 101 Witmer Road, Suite 700 Horsham, PA 19044 Phone 1-800-521-0754 Fax 215-442-9202 www.labrepco.com sales@labrepco.com Table of Contents Chapter 1.Cautionary

More information

Adam Equipment. CBD SERIES (P.N , Revision B, May 2011)

Adam Equipment. CBD SERIES (P.N , Revision B, May 2011) Adam Equipment CBD SERIES (P.N. 302666242, Revision B, May 2011) Adam Equipment Company 2011 Adam Equipment Company 2011 CONTENTS 1.0 INTRODUCTION...3 2.0 TECHNICAL SPECIFICATIONS...4 2.1 SPECIFICATIONS

More information

WM-25 USER S MANUAL. Manufacturer s Declaration of Conformity

WM-25 USER S MANUAL. Manufacturer s Declaration of Conformity HOLD UNIT WM-25 Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards, following the provisions of the below stated directives:

More information

CONTENTS. PRECAUTIONS... 4 PREFACE... 6 OVERALL VIEW... 6 DISPLAY & KEYBOARD... 7 OPERATIONS I. Programming Mode II. Sales Mode...

CONTENTS. PRECAUTIONS... 4 PREFACE... 6 OVERALL VIEW... 6 DISPLAY & KEYBOARD... 7 OPERATIONS I. Programming Mode II. Sales Mode... 2 e CONTENTS PRECAUTIONS... 4 PREFACE... 6 OVERALL VIEW... 6 DISPLAY & KEYBOARD... 7 OPERATIONS... 11 I. Programming Mode... 11 Chapter 1. Basic Operation... 12 Chapter 2. PLU Saving & Calling-up... 15

More information

INSTRUCTION MANUAL. Balances. Stable OHAUS. Mode. Units. Setup >O/T< Enter. Print OHAUS >O/T<

INSTRUCTION MANUAL. Balances. Stable OHAUS. Mode. Units. Setup >O/T< Enter. Print OHAUS >O/T< INSTRUCTION MANUAL Balances >O/T< OHAUS >O/T< >O/T< OHAUS >O/T< Ohaus Corporation, 19A Chapin Road, P.O. Box 2033, Pine Brook, NJ, 07058-2033, USA Declaration of Conformity We, Ohaus Corporation, declare

More information

OHAUS SCOUT BALANCE SCALE

OHAUS SCOUT BALANCE SCALE H-5848, H-5849, H-5850 π H-5851, H-5852, H-5853 H-5854, H-5855 1-800-295-5510 uline.com OHAUS SCOUT BALANCE SCALE CONTROL PANEL OVERVIEW OF CONTROLS CONTROL FUNCTIONS BUTTON Zero Yes Print Units No Function

More information

Cautions for Your Safety

Cautions for Your Safety . 2 Cautions for Your Safety Please comply with 'Cautions for Your Safety', which will lead you to use the product safely and properly to prevent any dangerous situations. Cautions are divided into 'Warning'

More information

DC-10. Dual Counting Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT

DC-10. Dual Counting Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT DC-10 Dual Counting Indicator Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT Specifications subject to change without prior notice V225 December

More information

ES210. Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd

ES210. Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd ES210 Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com Fax: +1 866 612 9088 North America Toll Free: 1-855-ANYLOAD (269 5623) TABLE OF

More information

600 g x 0.02 g DIGITAL BALANCE

600 g x 0.02 g DIGITAL BALANCE 600 g x 0.02 g DIGITAL BALANCE Model : GM-600P Your purchase of this DIGITAL BALANCE marks a step forward for you into the field of precision measurement. Although this DIGITAL BALANCE is a complex and

More information

STANDARD OPERATING PROCEDURE ACB SERIES ACB-600H PRECISION BALANCE

STANDARD OPERATING PROCEDURE ACB SERIES ACB-600H PRECISION BALANCE Ref.. Table of Contents Page 1. Scope 2 2. Objective 2 3. Definitions 2 4. Responsibility 3 5. Procedure 3 6. Precautions 14 7. References 14 8. Appendices 14 9. Revision History 14 Original Authorised

More information

Instruction Manual for. Torbal AGCN Series Balances

Instruction Manual for. Torbal AGCN Series Balances Instruction Manual for Torbal AGCN Series Balances 101 Witmer Road, Suite 700 Horsham, PA 19044 Phone 1-800-521-0754 Fax 215-442-9202 www.labrepco.com sales@labrepco.com Table of Contents Chapter 1.Cautionary

More information

CONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller...

CONTENTS. 1. Preface Features Technical Specifications Application of Dummy Plate Usage of Connector & Roller... 2 CONTENTS - RW-2601P Series Caution... 4 1. Introduction... 5 2. Features... 7 3. Technical Specifications... 7 4. Explanation of Frontal Aspect... 9 5. Test Mode...11 6. Set Mode... 14 7. Calibration

More information

TCM2 Series Counting Scale Operation Manual V1.0 Contents Subject to Change without Notice

TCM2 Series Counting Scale Operation Manual V1.0 Contents Subject to Change without Notice TCM2 Series Counting Scale Operation Manual V1.0 Contents Subject to Change without Notice 1 CONTENT 1. Specification... 3 2. Housing... 4 3. Faceplate... 4 4. Keys function Summary... 6 5. Weighing Operation...

More information

Precision Balance W3200 Series Operating Manual

Precision Balance W3200 Series Operating Manual Precision Balance W3200 Series Operating Manual Version 9-19-16 1 2 CONTENTS 1. INTRODUCTION. 4 2. INSTALLATION... 4 2-1. Unpacking.... 5 2-2. Specifications.... 5 2-3. Environmental Requirements... 5

More information

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct.

AL-Series INSTRUCTION MANUAL AL-311 AL-201S. American Weigh Scales, Inc. Analytical Balances American Weigh Scales, Inc. pcs% kgct. American Weigh Scales, Inc. AL-Series Analytical Balances INSTRUCTION MANUAL Max = 310g d=1mg e=10d STANDBY pcs% kgct ON/OFF MODE CAL UNIT PRINT AL-311 AL-201S Max = 210g d=0.1mg e=10d kgct STANDBY pcs%

More information

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower User Manual Waterproof Weighing Scale ELW Plus / ESW Plus ELW Plus Wipower Excell Precision Limited 2016. All rights reserved Worldwide. The information contained herein is the property of Excell Precision

More information

PLATINUM PRO1001DXP DIGITAL COUNTERTOP / PORTABLE BALANCE

PLATINUM PRO1001DXP DIGITAL COUNTERTOP / PORTABLE BALANCE PLATINUM PRO1001DXP PROFESSIONAL SERIES DIGITAL COUNTERTOP / PORTABLE BALANCE IMPORTANT PRINT FUNCTION LIMITATIONS Your GemOro Platinum PRO1001DXP precision balance features a useful, but limited print

More information

Counting Scale. FC-50Ki FC-20Ki FC-10Ki FC-5000i WM : PD

Counting Scale. FC-50Ki FC-20Ki FC-10Ki FC-5000i WM : PD ふ Counting Scale FC-50Ki FC-20Ki FC-10Ki FC-5000i WM : PD4000541 This manual and Marks All safety messages are identified by the following, WARNING or CAUTION, of ANSI Z535.4 (American National Standard

More information

User Manual MODEL DIGI SERI DS

User Manual MODEL DIGI SERI DS User Manual MODEL DIGI SERI DS Contents 1 MAIN FEATURES AND SPECIFICATION 1 1-1 Main Features 1 1-2 Specification 1 2 PRECAUTIONS 1 3 INSTALLATION AND START TO USE 2 3-1 Requirements before using 2 3-2

More information

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice. Digital Bench Scale Revision 1.2 September 14, 2000 Contents subject to change without notice. Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-0529 Tel (507) 238-8702

More information