WUNDER SA.BI.SRL EN USER MANUAL. MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual

Size: px
Start display at page:

Download "WUNDER SA.BI.SRL EN USER MANUAL. MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED. User Manual"

Transcription

1 MULTIFUNCTIONS ELECTRONIC SCALE MOD. W100 LED User Manual Read this manual carefully before using the instrument W100 SCALE W100 INDICATOR INDICE 2. BEFORE USING PAG SPECIFICATIONS PAG INDICATOR AND KEY FUNCTION PAG INSTALLATION PAG INSTRUCTIONS OF USE PAG SETUP (FUNCTION) CALIBRATION PAG. 5 7 MAINTANANCE AND ASSISTANCE PAG.14 W100LED REV.00 04/12/2016 1

2 2.BEFORE USING 1. Keep the scale dry, keep the scale away from water and rain, Clean the scale if necessary with dry cloth. 2. Keep the scale away from high temperature environment and wet 3. Please recharge the scale when ( ) is on 4. Drop and impact are prohibited 5. If the scale will not be used for a long period of time, please store the scale at dry place and recharge the scale every 3 months 3.SPECIFICATIONS Accuracy Load cell sensitivity range Class Ⅲ level 1.5~3.0mV /V Nonlinear 0.01%F.S System working voltage DC:5V Division value 1/2/5 auto setting Large LCD display connector Sampling serial output way Power Input:AC 120~240V Output:DC 12V/1A 1. Approx. 80mA Power Consunption 2. Approx. 95mA with backlight and RS232 interface Sample Rate 20 times per second (can select Internal resolution 300'000 ~ 600'000 The connector of load cell and indicator: PIN1 : E + PIN2 : E- PIN3 : S+ PIN4 : S - PIN5 : schermo W100LED REV.00 04/12/2016 2

3 4. INDICATOR AND KEY FUNCTION OFF key: Press and hold the OFF key and the display will show off for 2 seconds then the scale will turn off automatically. ON key: Press the ON key to turn on the scale. The scale will start self-adjusting sequence then will stabilize in 0. UNITS / ESC key: UNITS: To select desired weighing unit. ESC : To escape (exit) setting in setup mode. ZERO / key: ZERO : To reset the weight to 0, but the displayed weight value has to be less than ± 2% of maximum capacity. : To move one space to the left or downward in setup mode. TARE / key: TARE : To subtract the container weight. Maximum tare = full capacity : To move one space to the right or upward in setup mode. To the right Net/Gross / key: Net/Gross : To see gross and net weight when the scale is on tare status. All other keys will be disabled when gross weight is activated. : To increase values upward in setup mode. PRINT / key: PRINT : Manually transmitting data through RS232 to computer or printer at normal weighing mode (RS232 setup must be set at keyboard transmission or 232 6) : Works as enter key in setup mode DISPLAY W100LED REV.00 04/12/2016 3

4 5.INSTALLATION Make sure that: a. Connect the load cell signal and power to the indicator properly. b. Place the scale on a level and strong surface. c. The indicator is turned on. d. The ZERO INDICATOR is on. If not, press ZERO to set display to zero. KIT IMBALLO BILICO CON TERMINALE W100: 1. PIATTAFORMA 2.TERMINALE W COLONNA 4.ALIMENTATORE 5. SUPPORTO REGOLABILE TERMINALE 6. MANUALE ISTRUZIONI 6. INSTRUCTIONS OF USE Standard Calibrations: Press the ZERO / key and the PRINT / key in weighing mode to start Standard Calibrations ECF-1 ECF-3 Weight Calibration (Zero and Span) ECF-2 Zero Calibration Span Calibration When the scale is programmed for Approval (LF 6), standard calibration will be locked PRINT /:Net/Gross / : ZERO / : UNITS / ESC:ESC TARE / : ECF-1 Press the key to start or press the ESC key to exit menu and back to weighing mode ECF-2 Press the key to start or press the ESC key to exit menu and back to weighing mode ECF-3 Press the key to start or press the ESC key to exit menu and back to weighing mode W100LED REV.00 04/12/2016 4

5 ECF-1 Weight Calibration : ECF-1 Press the key to start Weight Calibration (Press the ESC key to exit back to weighing mode) CAL2 Press the key to calibrate zero point (Press the ESC key to terminate calibration back to menu ECF-1) kg Use,,,0~9 and then key to enter the weight to be calibrated (Press the ESC key to terminate calibration back to menu ECF-1) kg Place the required weight mass onto the scale as indicated on display and press the key to calibrate the scale (Press the ESC key to terminate calibration back to menu ECF-1) kg Calibration procedure completed and the scale will return back to weighing mode automatically ECF-2 Zero Calibration : ECF-2 Press the key to start Zero Calibration (Press the ESC key to exit back to weighing mode) CAL2 Press the key to calibrate zero point (Press the ESC key to terminate calibration back to menu ECF-2) 0.00kg Zero Calibration procedure completed and the scale will return back to weighing mode automatically ECF-3 SPAN Calibration : ECF-3 Press the key to start Span Calibration (Press the ESC key to exit back to weighing mode) kg Use,,,0~9 and then key to enter the weight to be calibrated (Press the ESC key to terminate calibration back to menu ECF-3) kg Place the required weight mass onto the scale as indicated on display and press the key to calibrate the scale W100LED REV.00 04/12/2016 5

6 (Press the ESC key to terminate calibration back to menu ECF-3) kg Calibration procedure completed and the scale will return back to weighing mode automatically Standard Functions Setup Press the TARE / and the PRINT / key in weighing mode to start Standard Functions Setup UF-1 Internal Value UF-2 Check Weighing UF-3 Auto Power-off UF-4 Standby time UF-5 Hold UF-6 RS232 Output UF-7 UF-8 UF-9 ADC Update Rate Display Condition at Zero Gravitational (G value) Pre-Calibration marks function locked when LF 6 is set as Approval Version PRINT / : Net/Gross / : ZERO / : UNITS / ESC :ESC TARE / : UF-1 Press the key to start or press the ESC key to exit menu and back to weighing mode UF-2 Press the key to start or press the ESC key to exit menu and back to weighing mode UF-3 Press the key to start or press the ESC key to exit menu and back to weighing mode UF-4 Press the key to start or press the ESC key to exit menu and back to weighing mode UF-5 Press the key to start or press the ESC key to exit menu and back to weighing mode UF-6 Press the key to start or press the ESC key to exit menu and back to weighing mode UF-7 Press the key to start or press the ESC key to exit menu and back to weighing mode UF-8 Press the key to start or press the ESC key to exit menu and back to weighing mode W100LED REV.00 04/12/2016 6

7 UF-9 Press the UF-1Press the key to start or press the ESC key to exit menu and back to weighing mode UF-1 Internal Value: key to see the internal value or pressthe ESC key to exit menu and back to weighing mode Press the key to continue or the ESC key to exit back to menu UF-1 Press the key to see the battery voltage or the ESC key to exit back to menu UF-1 UF-1 Use and then keys to continue with other setups or press the ESC key to exit menu and back to weighing mode UF-2 Check Weighing : L Set LO (low) weight H Set HI (high) weight O 000 Program I/O conditions LO set as 0 will clear all check weigh values Check weighing conditions can be set independently for each of the weighing units and counting mode All settings will be saved until manually cleared Last entry will be displayed before setup This function is locked when UF-5 is set as HOLD 1 UF-2 Press the key to start or press the ESC key to exit menu and back to weighing mode L Use,,,0~9 and then key to set LO weight value (Press the ESC key to exit the setup and back to menu UF-2) H Use,,,0~9 and then key to set HI weight value (Press the ESC key to exit the setup and back to menu UF-2) W100LED REV.00 04/12/2016 7

8 O 000 Use,,,0~9 and then key to set I/O SET value (Press the ESC key to exit the setup and back to menu UF-2) UF-2U se and then key to continue with other setups or press the ESC key to exit menu and back to weighing mode UF-3 Auto Power-off : AoFF 00 Auto power-off disable AoFF 01 The scale turns off automatically in 1 minute when the scale is not in operation and weight at 0 Auto power-off timer up to 99 minutes (AoFF01~AoFF 99) Factory default: AoFF 10 UF-3 Press the key to start or press the ESC key to exit menu and back to weighing mode AoFF10 Use and then key to enter Auto Power-off time (Press the ESC key to exit the setup and back to menu UF-3) UF-3 Use and then key to continue with other setups or press the ESC key to exit menu and back to weighing mode UF-4 standby time : HOLD 0 HOLD 1 PCt XXX timexx UF-5 Hold : Hold function off Animal (motion) Hold function To set the range from 001 ~ 100 of the animal hold (for HOLD 1 only) To set times within the hold range (for HOLD 1 only) This function is locked when LF 6 is set as Approval Version Factory default: HOLD 0 UF-5 Press the key to start or press the ESC key to exit menu and back to weighing mode W100LED REV.00 04/12/2016 8

9 HOLD0 Use and then key to select Hold modes (Press the ESC key to exit the setup and back to menu UF-5) UF-5 Use and then key to continue with other setups or press the ESC key to exit menu and back to weighing mode HOLD 1 mode: UF-5 Press the key to start or press the ESC key to exit menu and back to weighing mode HOLD 1 Use and then key to select Hold 1 mode (Press the ESC key to exit the setup and back to menu UF-5) PCt 010 Use 0~9 and then key to enter the hold range (Press the ESC key to exit the setup and back to menu UF-5) time 8 Use and then key to select times (Press the ESC key to exit the setup and back to menu UF-5) UF-5 Use and then key to continue with other setups or press the ESC key to exit menu and back to weighing mode UF-6 RS232 : RS232 disable Stable output Format Stream output Format Manual output Format Stable output Format Stream output Format Manual output Format 2 RS232 Baud rate b 1200 Baud rate 1200 b 2400 Baud rate 2400 b 4800 Baud rate 4800 b 9600 Baud rate 9600 b19200 Baud rate W100LED REV.00 04/12/2016 9

10 b Baud rate Communication Protocol UART signal of EIA-RS232 C Format: 1. Serial output: 1200 / 2400 / 4800 / 9600 / / BPS 2. Data bits : 8 BITS 3. Parity bits : None 4. Stop bits : 1 BIT Start bit Data bits Stop bits Format 1 (232 1 ~ 3 ) : HEAD1 ( 2 BYTES ) HEAD2 ( 2 BYTES ) OL - Over Load ST - Stable NT - Net Weight US - Unstable GS - Gross Weight Fixed 18 BYTES ASCII (kg g t lb) HEAD1, HEAD2, DATA UNIT CR LF Fixed 21 BYTES ASCII (tl.t lboz) HEAD1, HEAD2, DATA UNIT CR LF Fixed 19 BYTES ASCII (pcs) HEAD1, HEAD2, DATA UNIT CR LF Output examples : 1. Example kg Stable net weight : W100LED REV.00 04/12/

11 S T, N T, k g 0D 0A 2. Example lb unstable gross weight : U S, G S, l b 0D 0A 3. Example lb oz unstable gross weight : S T, G S, l b o z 0D 0A 4. Example pcs stable net weight : S T, N T, p c s 0D 0A Format 2 (232 4 ~ 6) : Fixed 12 BYTES ASCII (kg g t lb) DATA UNIT CR LF Fixed 15 BYTES ASCII (tl.t lboz) DATA UNIT CR LF Fixed 13 BYTES ASCII (pcs) DATA UNIT CR LF Output examples : 1. Example kg stable net weight : k g 0D 0A 2. Example lb unstable gross weight : l b 0D 0A 3. Example lb oz unstable gross weight : l b o z 0D 0A 4. Example pcs stable net weight : p c s 0D 0A UF-6 Press the key to start or press the ESC key to exit menu and back to weighing mode W100LED REV.00 04/12/

12 232 0Use and then key to enter RS232 output format (Press the ESC key to exit the setup and back to menuuf-6) b9600 Use and then key to select baud rate (Press the ESC key to exit the setup and back to menu UF-6) UF-6 Use and then key to continue with other setups or press the ESC key to exit menu and back to weighing mode UF-7ADC Update Rate : SPEEd 1 Standard speed 15 hz SPEEd 2 High speed 30 hz SPEEd 3 Low speed 7.5 hz This function is locked when UF-5 is set as HOLD 1 This function is locked when LF 6 is set as Approval Version Factory default: SPEEd 1 UF-7 Press the key to start or press the ESC key to exit menu and back to weighing mode SPEEd1 Use and then key to select ADC speed(press the ESC key to exit the setup and back to menu UF-7) UF-7 Use and then key to continue with other setups or press the ESC key to exit menu and back to weighing mode UF-8 Zero Weight Display Condition : ZP 0 Off ZP 1 One division not to display at zero ZP 2 Two divisions not to display at zero ZP 3 Three divisions not to display at zero ZP 4 Four divisions not to display at zero ZP 5 Five divisions not to display at zero This function is locked when UF-5 is set as HOLD 1 This function is locked when LF 6 is set as Approval Version W100LED REV.00 04/12/

13 Factory default: ZP 0 UF-8 Press the key to start or press the ESC key to exit menu and back to weighing mode ZP0 Use and then key to select how many divisions not to display at zero (Press the ESC key to exit the setup and back to menuuf-8) UF-8 Use and then key to continue with other setups or press the ESC key to exit menu and back to weighing mode UF-9 Standard Gravitational (G value) Pre-Calibration: Approval Model: When the CAL switch is at OFF, 10 gravitational values can be entered and can be also recalled for reference. After 10 gravitational values have been filled, the scale will only allow recalling previous 10 values (-00- ~ -09-) for reference and adding new value will not be allowed. Internal Gravitational Calibration or LF1 Internal Weight Calibration has to be done to erase previously entered values. Non-approval Model: Even the scale allows to do the Standard Calibration, Gravitational Calibration can help to provide accurate scale when end users received it without all the trouble to recalibrate thescale. Pre-calibration is allowed when the scale is setup as non-approval model or the CAL switch is at ADJ position. Gravitational value will be saved at -00- and will be replaced each time a new value has been entered. Sender G value: Set it before Weight Calibration Recipient G value: Set it after Weight Calibration The G value will be denied when the value is greater than (Polar G value) or less than (Equator G value) Factory Default: UF-9 Press the key to start or press the ESC key to exit menu and back to weighing mode -03- The display will show the last value for 1 second Use keys to see previous entered values. The display will stay at 00 if no value has been entered W100LED REV.00 04/12/

14 -02- The display will show the last value for 1 second Use keys to see previous entered values. The display will stay at 00 if no value has been entered Press the key to start (Press the ESC key to exit the setup and back to menu UF-9) Use 0~9 and then key to enter the Gvalue (Press the ESC key to exit the setup and back to menu UF-9) Press the key to confirm the G value UF-9 Use and then key to continue with other setups or press the ESC key to exit menu and back to weighing mode 7. MAINTENANCE AND ASSISTANCE For better and longer duration of the product it should receive thorough general cleaning periodically. The instrument must be cleaned with a soft cloth moistened with water or neutral detergent, without using solvents or abrasive substances. If the instrument remains idle for a long period, remove the batteries from the terminal. During shipping, make sure not to subject the instrument to blows or excessive mechanical stress. In case of repairs or assistance, contact your dealer or an authorised service centre W100LED REV.00 04/12/

CONTENTS. PRECAUTIONS Introduction Installation... 7

CONTENTS. PRECAUTIONS Introduction Installation... 7 2 CONTENTS PRECAUTIONS... 4 1. Introduction... 6 2. Installation... 7 2.1 Unpacking... 7 2.2 Illustration of the installation for plastic shied... 7 2.3 Selecting the location... 8 2.4 Leveling the scale...

More information

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT

DWP-98 Series. Counting scale. User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT c DWP-98 Series Counting scale User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT Specifications subject to change without prior notice CONTENTS 1. INSTALLATION

More information

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION

UWE-1707 SERIES CONTENTS OPERATION MANUAL ELECTRONIC WEIGHING INDICATOR 1. SPECIFICATIONS 2. INSTALLATION UWE-1707 SERIES CONTENTS ELECTRONIC WEIGHING INDICATOR OPERATION MANUAL 1. SPECIFICATIONS PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE 2. INSTALLATION 3. ROUTINE OPERATION

More information

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide

DWP-PC SERIES PRICE COMPUTING SCALE User s Guide DWP-PC SERIES PRICE COMPUTING SCALE User s Guide PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE INSTRUMENT Specifications subject to change without prior notice CONTENTS 1. INSTALLATION

More information

MWP SERIES. High Precision

MWP SERIES. High Precision MWP SERIES High Precision 1. INTRODUCTION------------------------------------------------1 2. INSTALLATION---------------------------------------------------2 2.1 Unpacking---------------------------------------------------------------

More information

PS-IN202 Weighing Indicator User Manual

PS-IN202 Weighing Indicator User Manual PS-IN202 Weighing Indicator User Manual Version 2015.05 Contents FRONT AND REAR VIEW OF THE INDICATOR CHAPTER 1 CONNECTIONS 1.1 WHAT'S IN THE BOX 1.2 CONNECTING TO THE WEIGH PLATFORM 1.3 CONNECTION TO

More information

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED

D-500s Indicator D LED. User Instructions. English Issue September SangR. Page 2. User s manual of Sang D-500s LED D-500s Indicator D - 500 LED User Instructions English 8921-004210 Issue September 2010 1 2-2 0 1 0 D 6 0 0 4 6 7 5 Page 2 D-500s Indicator Page 2 Table of Content Section 1: Introduction. 1.1 Introduction

More information

NOTE. This is warning & caution mark. This is hazard alert mark. This is useful information mark

NOTE. This is warning & caution mark. This is hazard alert mark. This is useful information mark 2 NOTE (1) The unauthorized copying of some or all of this manual is prohibited. (2) The information contained herein is subject to change without notice. (3) If there are any questions such as wrong or

More information

SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual

SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual www.scintex.com.au sales@scintex.com.au SCS3MT080, SCS3MT100, SCS3MT120, SHDHS1500 & SPLS1000 User Manual Technical Data Working Temperature:-5 to 35 C Storage Temperature:-25 to 50 C Stainless Steel Casing:

More information

Bright Advance Corporation USER INSTRUCTIONS

Bright Advance Corporation USER INSTRUCTIONS Briht Advance Corporation USER INSTRUCTIONS Weihin Scale Briht Advance Corporation TABLE OF CONTENTS BEFORE USING THE SCALE2 PREPARING TO USE THE SCALE2 LCD DISPLAY3 KEYBOARD FUNCTION4 OPERATION5 1 DISPLAY

More information

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6

1. Introduction Page 2. Specifications Page Installation Page Key Functions Page Operations Page 6. Check Weighing Page 6 Contents: 1. Introduction Page 2 Specifications Page 2 2. Installation Page 3 3. Key Functions Page 4 4. Operations Page 6 Check Weighing Page 6 Accumulation Page 7 Parts Counting Page 7 Print (RS232C)

More information

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved.

Kilotech. KRS SWP Series. Counter-top weighing scale. NTEP (USA) and Measurement Canada approved. Kilotech KRS SWP Series Counter-top weighing scale NTEP (USA) and Measurement Canada approved www.kilotech.com KILOTECH KRS SWP series Weighing Scale NOTE: Le manuel en Français est disponible au www.kilotech.com.

More information

KW serial. User s guide. Bench Scales UGKW-E0302

KW serial. User s guide. Bench Scales UGKW-E0302 KW serial Bench Scales User s guide UGKW-E0302 KW serial bench scale user s manual Table of Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS.. 2 SECTION 3 INSTALLATION.3 SECTION 4 KEY DESCRIPTIONS

More information

Trade Approved Version NMI: S520

Trade Approved Version NMI: S520 @Weigh BW/BWS Series Trade Approved Version NMI: S520 Weighing Indicator User s guide UGBW-E1.09 Table of Contents SECTION 1 INTRODUCTION. 1 SECTION 2 SPECIFICATIONS... 2 SECTION 3 INSTALLATION.3 3. 1

More information

EB300 Weighing Scale Operation Manual

EB300 Weighing Scale Operation Manual EB300 Weighing Scale Operation Manual EB300 User Manual Page 1 of 18 TABLE OF CONTENTS 1. Safety Warnings... 3 2. Features..... 3 3. Options.......... 4 4. Product packaging.. 4 5. Display and keyboard.....

More information

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows:

USER S GUIDE. Weighing Indicator. globalindustrial.com. Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows: Use of RS232 Port Using Windows for the Printer Driver, Adjust Computer Settings as Follows: Click On Start Pick Program Weighing Indicator USER S GUIDE Pick Accessories Pick Communications Pick Hyper

More information

EXCELL PRECISION CO., LTD.

EXCELL PRECISION CO., LTD. Excell Precision Limited 24. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without liability for errors or omissions. No part

More information

TWP series. Weighing Indicator Service Manual

TWP series. Weighing Indicator Service Manual TWP series Weighing Indicator Service Manual CONTENTS 1. SPECIFICATIONS....3 2. INSTALATION AND PRECAUTIONS..4 Load cell connection......4 Power operation..5 Battery operation.5 3. NAME AND FUNCTIONS........6

More information

9. FUNCTION MENU SETTINGS -TION FUNCTION DESCRIPTION DEFAULT. VALUE F0 H-L SEt Lo Set a value for the Low

9. FUNCTION MENU SETTINGS -TION FUNCTION DESCRIPTION DEFAULT. VALUE F0 H-L SEt Lo Set a value for the Low ROW Weighing Scale CONTENTS 1. INTRODUCTION 1 2. KEY DESCRIPTIONS 1 3. BASIC OPERATION.. 2 3.1 Zeroing the display..2 3.2 Taring. 2 4. CHECK-WEIGHING..3 4.1 About check-weighing 3 4.2 Set limits 4 4.3

More information

TWP-W. Weighing Indicator Service Manual

TWP-W. Weighing Indicator Service Manual TWP-W Weighing Indicator Service Manual CONTENTS 1. SPECIFICATIONS....3 2. INSTALATION AND PRECAUTIONS..4 Load cell connection......4 Power operation..5 Battery operation.5 3. NAME AND FUNCTIONS........6

More information

COMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery.

COMPLETE MANUAL. WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery. COMPLETE MANUAL WEIGHING INDICATOR TI-1200 and TI-1200-S TI-1200 with rechargeable battery. TI-1200-S without rechargeable battery and with a smaller cabinet. Note: When TI-1200 is shipped as a part of

More information

OCEAN WATERPROOF WEIGHING SCALE USER MANUAL

OCEAN WATERPROOF WEIGHING SCALE USER MANUAL OCEAN WATERPROOF WEIGHING SCALE USER MANUAL Excell Precision Limited 2006. All rights reserved Worldwide. The information contained herein is the property of Excell Precision Limited and is supplied without

More information

TRWS series. Waterproof indicator User s guide UGTRWS-E1.1

TRWS series. Waterproof indicator User s guide UGTRWS-E1.1 TRWS series Waterproof indicator User s guide UGTRWS-E1.1 Table of Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS.. 2 SECTION 3 INSTALLATION.3 SECTION 4 KEY DESCRIPTIONS 5 SECTION 5 DISPLAYS.6

More information

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050

Weighing Indicator USER S GUIDE. globalindustrial.com. globalindustrial.com. 11 Harbor Park Drive Port Washington, NY 11050 Weighing Indicator USER S GUIDE 0713 11 Harbor Park Drive Port Washington, NY 11050 Table of Contents I Main Specifications.............................3 II Display and Keyboard..........................4

More information

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com DPI 820. Dual Input Thermometer. User manual.

99 Washington Street Melrose, MA Fax TestEquipmentDepot.com DPI 820. Dual Input Thermometer. User manual. 99 Washington Street Melrose, MA 0276 Fax 78-665-0780 TestEquipmentDepot.com DPI 820 Dual Input Thermometer User manual A B 0 0 0a 9a A 2 9 8 2 3 7 6 4 5 B 2 A2 6 5 4 3 22 7 8 2 9 20 Test Equipment Depot

More information

ES210. Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd

ES210. Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd ES210 Animal & Vet Scale User s Manual (V1611) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com Fax: +1 866 612 9088 North America Toll Free: 1-855-ANYLOAD (269 5623) TABLE OF

More information

! User Manual Rev. 1

! User Manual Rev. 1 User Manual Rev. 1 Warnings For safety operation of the weighing indicator, please follow the following warning/ safety instructions: Calibration inspection and maintenance of the indicator are prohibited

More information

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower

User Manual. Waterproof Weighing Scale. ELW Plus / ESW Plus ELW Plus Wipower User Manual Waterproof Weighing Scale ELW Plus / ESW Plus ELW Plus Wipower Excell Precision Limited 2016. All rights reserved Worldwide. The information contained herein is the property of Excell Precision

More information

1. Introduction Specifications Operation Guide Trouble-shooting Note... 13

1. Introduction Specifications Operation Guide Trouble-shooting Note... 13 Content 1. Introduction... 1 Notice... 1 Safety Guide... 1 2. Specifications... 2 Features... 2 Specifications... 3 Capacity and Resolution... 4 Schematic Diagram... 4 Dimension... 5 3. Operation Guide...

More information

Digital Weighing Indicator XK3190-A12 User Manual

Digital Weighing Indicator XK3190-A12 User Manual Digital Weighing Indicator XK3190-A12 User Manual TPS-A12/A12E Content CHAPTER 1 MAIN SPECIFICATION....-2- CHAPTER 2 INSTALLATION......-3-2.1 FRONT AND BACK VIEW OF INDICATOR....-3-2.2 KEY FUNCTIONS......-4-2.3

More information

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY

CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 DISPLAY AND KEY: 7.0 DEALER S SETTING CAUTIONS PREPARATION DISPLAY CONTENTS 1.0 CAUTIONS AND PREPARATION 2.0 KEYPAD AND DISPLAY 3.0 OPERATION 4.0 SETTING OPERATION 5.0 ERROR INFORMATION AND SPECIFICTION 6.0 ASSEMBLE INSTRUCTION 7.0 DEALER S SETTING 1.0 CAUTIONS AND PREPARATION

More information

Model PC-400 Portion Control Scale

Model PC-400 Portion Control Scale Model PC-400 Portion Control Scale Operator s Manual Doran Scales, Inc. 1315 Paramount Pkwy Batavia, IL 60510 1-800-262-6844 www.doranscales.com Man. #233 Manual Revision 0.1 i Table of Contents Section

More information

BW/BWS Weighing Indicator

BW/BWS Weighing Indicator BW/BWS Weighing Indicator - 1 - CONTENTS 1. SPECIFICATION... 2 2. INTRODUCTION... 3 3. INSTALLATION. 4 Precautions 4 Parts 4 Installation.. 5 4. KEYS DESCRIPTION... 6 Key Board... 6 Secondary functions

More information

WM-25 USER S MANUAL. Manufacturer s Declaration of Conformity

WM-25 USER S MANUAL. Manufacturer s Declaration of Conformity HOLD UNIT WM-25 Manufacturer s Declaration of Conformity This product has been manufactured in accordance with the harmonised European standards, following the provisions of the below stated directives:

More information

MI101 / MI102 / MI102S INDICATOR

MI101 / MI102 / MI102S INDICATOR MI101 / MI102 / MI102S INDICATOR USER GUIDE Preface Thank you for purchasing the MI series indicator from Millennium Mechatronics Limited, New Zealand. The MI101/MI102 Indicator is an accurate, fast and

More information

Calibration. RS 232 and other out puts. Q: Will a standard RS232 cable work with an Ohaus balance?

Calibration. RS 232 and other out puts. Q: Will a standard RS232 cable work with an Ohaus balance? Calibration Q: What is the difference between a Span and a Linearity calibration? A: A span calibration sets the balance at 2 points Usually zero and full capacity. A linearity calibration sets the balance

More information

CAUTIONS... 4 INTRODUCTION...

CAUTIONS... 4 INTRODUCTION... CONTENTS CAUTIONS... 4 INTRODUCTION... 6 FEATURES & MAIN FUNCTIONS... 6 SPECCIFICATION... 7 PART NAME & KEY FUNCTION... 8 SYSTEM MODE...11 GENERAL FUNCTION & DESCRIPTION... 16 CONVERSION MODE... 18 PRINT

More information

Totalcomp TLI Indicator. Operation and Maintenance Manual Manual

Totalcomp TLI Indicator. Operation and Maintenance Manual Manual Totalcomp TLI Indicator Operation and Maintenance Manual Manual V1.08-0.06E DT: 04/29/2013 - - CONTENTS Precautions... 2 1. SPECIFICATIONS... 3 2. INTRODUCTION. 4 3. INSTALLATION... 5 Unpacking 5 Parts

More information

EHC-WF. User/Technical Manual. Contents subject to change without notice

EHC-WF. User/Technical Manual. Contents subject to change without notice EHC-WF User/Technical Manual Contents subject to change without notice Version 1.0 7/2017 TABLE OF CONTENTS 1. INTRODUCTION... 1 General and Safety Information... 1 Specifications... 1 2. Unpacking and

More information

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series

Table of Contents. Laboratory Balances. Instruction Manual - TORBAL AGC Series Laboratory Balances Table of Contents Cautionary Notes and Precautions...3 1. Specification... 4 2. Keys and Display Indicators... 6 3. Commands and abbreviations...7 4. Parts Description...8 5. Unpacking

More information

IDS-801 Series Compact Bench Counting Scale. User Manual

IDS-801 Series Compact Bench Counting Scale. User Manual IDS-801 Series Compact Bench Counting Scale User Manual 1. INTRODUCTION... 3 1.1. Product Description... 3 1.2. General Features... 3 1.3. Safety Precautions... 3 2. INSTALLATION... 4 2.1. Unpacking...

More information

Calibration & Connectivity

Calibration & Connectivity Calibration & Connectivity TS-700 Series Digital Indicators This document supplements the User s Guide TS-700 MS TS-700 SS TS-700 WB Full Function/Advanced Function Digital Indicator www.trinerscale.com

More information

Digital Weight Indicator Setup / Operation Manual

Digital Weight Indicator Setup / Operation Manual Digital Weight Indicator Setup / Operation Manual Load Cell Central follows a policy of continuous improvement and reserves the right to change specifications without notice. 2013 Load Cell Central Toll

More information

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4.

Table of Contents. 3-1 Specifications & Features Front Panel Display Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4. Table of Contents 1. Introduction 1 2. Precaution... 1 3. Product Introduction 3-1 Specifications & Features... 3-2 Front Panel 3-2-1 Display 3-2-2 Keyboard. 3-3 Rear Panel. 3-4 Power Supply. 4. Installation

More information

SAC / SHC / SHC-CH SERIES

SAC / SHC / SHC-CH SERIES This document hosted by: www.oldwillknottscales.com SAC / SHC / SHC-CH SERIES HIGH PRECISION COUNTING SCALE OPERATION MANUAL PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE ATTEMPT TO OPERATE THE SCALE July

More information

AELP PALLET BEAMS SCALES

AELP PALLET BEAMS SCALES Adam Equipment AELP PALLET BEAMS SCALES (P.N. 4327, Rev. A7, Mar 2016) Adam Equipment Company 2016 Adam Equipment Company 2016 CONTENTS 1.0 INTRODUCTION... 2 2.0 TECHNICAL SPECIFICATIONS... 3 3.0 UNPACKING

More information

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements www.adwainstruments.com Dear Customer, Thank you for choosing an Adwa product. Please read carefully this manual before starting

More information

INTRODUCTION INSTALLATION

INTRODUCTION INSTALLATION INTRODUCTION SNUG II precision balance series contains five models ---- SNUG II -150,300, 600, 1500 and 3000 with weighing capacities of 150g, 300g, 600g, 1500g and 3000g respectively. The display resolution

More information

Multi-Function Smart Indicator User Manual

Multi-Function Smart Indicator User Manual Multi-Function Smart Indicator User Manual EC30006 Content 1 Notice... 2 2 Specification... 2 3 Main parameter... 3 4 How to fix... 3 5 Port... 4 6 On/Off... 4 7 Charging... 4 8 Display... 5 9 Screen keypad...

More information

PCE Americas Inc. PCE Instruments UK Ltd. 711 Commerce Way Units 12/13, Southpoint Business Park Suite 8 Ensign Way Jupiter, FL 33458 Hampshire / Southampton USA United Kingdom, SO31 4RF Phone: 561-320-9162

More information

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.

American Weigh Scales H-110. User Manual. H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4. American Weigh Scales H-110 User Manual H-110 (110lb x 0.05lb) Copyright 2010 American Weigh Scales, Inc. All rights reserved. Rev. 4.0 H-110 Thank you for purchasing the H-110 digital hanging scale. Please

More information

1. On / Off. 2. Initial reset to zero

1. On / Off. 2. Initial reset to zero EN USER MANUAL 1 Index 1. On / Off... 3 2. Initial reset to zero... 3 3. Keypad operation... 4 3.1. ON / OFF... 4 3.2. MENU... 4 3.3. TARE... 5 3.4. PRINT / SUM... 6 4. Description of LCD display... 8

More information

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1.

Userʼs Guide. 1200g High Precision Scale. 1200g High Precision Scale. Legal for Trade. Includes RS-232 interface port. UG Version 1. Userʼs Guide 1200g High Precision Scale Legal for Trade 1200g High Precision Scale Includes RS-232 interface port UG Version 1.2_12-30-13 !!!! CALIBRATION WARNING!!!! Calibration AND inspection of calibration

More information

CW Series Check Weighing Scales. Instruction Manual

CW Series Check Weighing Scales. Instruction Manual CW Series Check Weighing Scales Instruction Manual CW Series Instruction Manual Index Item Number Description Page Unpacking and Inspecting 2 Specifications 3 Main Operating Components 4 Zero Point Adjustment

More information

Cautions for Your Safety

Cautions for Your Safety . 2 Cautions for Your Safety Please comply with 'Cautions for Your Safety', which will lead you to use the product safely and properly to prevent any dangerous situations. Cautions are divided into 'Warning'

More information

MODEL PS-11 DIGITAL PORTION SCALE

MODEL PS-11 DIGITAL PORTION SCALE MODEL PS-11 DIGITAL PORTION SCALE OWNER S MANUAL CARDINAL SCALE MFG. CO. 8528-M310-O1 Rev B 203 E. Daugherty, Webb City, MO 64870 USA 11/10 Ph: 417-673-4631 Fax: 417-673-2153 www.detecto.com Technical

More information

Digital Bench Scale. Revision 8.93 August 12, 1993

Digital Bench Scale. Revision 8.93 August 12, 1993 Digital Bench Scale Revision 8.93 August 12, 1993 Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-0529 Tel (507) 238-8702 Fax (507) 238-8271 E-mail: sales@salterbrecknell.com

More information

Weighing Indicator Service Manual V1.24X

Weighing Indicator Service Manual V1.24X Weighing Indicator Service Manual V1.24X CONTENTS 1. PRECAUTIONS.3 2. SPECIFICATIONS....4 3. INTRODUCTION....5 4. INSTALLATION..6 Unpacking 6 Installation 6 Load cell connections......7 Connect Adaptor

More information

KERN FOB. non-approval. KERN & Sohn GmbH. Service Manual Electronic Precision Balances Page 2. Version 1.0. Tel: 0049-[0]

KERN FOB. non-approval. KERN & Sohn GmbH. Service Manual Electronic Precision Balances Page 2. Version 1.0. Tel: 0049-[0] KERN & Sohn GmbH Ziegelei 1 Tel: 0049-[0]7433-9933-0 D-72336 Balingen-Frommern Fax: 0049-[0]7433-9933-149 E-Mail: info@kern-sohn.de Internet: www.kern-sohn.de E Service Manual Electronic Precision Balances

More information

Technical Parameter... 4 Installation and Connection... 5

Technical Parameter... 4 Installation and Connection... 5 2 CONTENTS Technical Parameter... 4 Installation and Connection... 5 1. Indicator Diagram... 5 2. Loadcell Connection... 6 3. Serial Communication interface and Scoreboard... 7 Operation Instruction...

More information

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual

GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual GMC-206/215/230 Digital Desktop Weighing Scale Operation Manual Version 2.1 Gamma Scale Tel: (905) 455-8333 Fax: (905) 455-0658 E-mail: info@gammascale.com Website: www.gammascale.com 1. Technical Parameters

More information

Model PC-400 Portion Control Scale

Model PC-400 Portion Control Scale Model PC-400 Portion Control Scale Technical Manual Doran Scales, Inc. 1315 Paramount Pkwy Batavia, IL 60510 1-800-262-6844 www.doranscales.com MAN0231 Revision 3.2 i Table of Contents Section 1. Unpacking

More information

TI-500 Plus DIGITAL WEIGHT INDICATOR Setup / Operation Manual

TI-500 Plus DIGITAL WEIGHT INDICATOR Setup / Operation Manual TI-500 Plus DIGITAL WEIGHT INDICATOR Setup / Operation Manual Revision 1.0 975 Deerfield Parkway Buffalo Grove, IL 60089 April 3, 2008 Tel (847) 419-9180 Fax (847) 419-1515 http://www.transcell.net i TABLE

More information

CONTENTS PRECAUTIONS... 3 INSTALLATION... 4 ZERO... 9 TARE PRE-TARE AUTO TARE SELECTION OF WEIGHING UNIT... 16

CONTENTS PRECAUTIONS... 3 INSTALLATION... 4 ZERO... 9 TARE PRE-TARE AUTO TARE SELECTION OF WEIGHING UNIT... 16 CONTENTS PRECAUTIONS... 3 INSTALLATION... 4 FUNCTIONS ZERO... 9 TARE... 10 PRE-TARE... 12 AUTO TARE... 14 SELECTION OF WEIGHING UNIT... 16 UNIT IN USE AND INITIAL WEIGHING UNIT SETTING... 17 ACCUMULATION......19

More information

Weighing Indicator M701. Handrail scales. REV: M1, April,05,2014 (v )

Weighing Indicator M701. Handrail scales. REV: M1, April,05,2014 (v ) Weighing Indicator M701 Handrail scales REV: M1, April,05,2014 (v3.09-3.014) CONTENTS 1. PRECAUTIONS..2 2. INTRODUCTION 3 3. SPECIFICATIONS...4 3.1Specifications...4 3.2 Load Cell Specification......5

More information

American Weigh Scales, Inc. AMW-BENCH. D i g i t a l T a b l e t o p S c a l e. User Manual

American Weigh Scales, Inc. AMW-BENCH. D i g i t a l T a b l e t o p S c a l e. User Manual g American Weigh Scales, Inc. AMW-BENCH D i g i t a l T a b l e t o p S c a l e Hold Mode Tare ON/OFF AMW-500i AMW-1000 AMW-2000 User Manual AMW-BENCH Manual Thank you for purchasing the American Weigh

More information

PRW series. Bench Scale. User s guide UGPRW-E1.01

PRW series. Bench Scale. User s guide UGPRW-E1.01 PRW series Bench Scale User s guide UGPRW-E1.01 Table of Contents SECTION 1 INTRODUCTION 1 SECTION 2 SPECIFICATIONS.. 2 SECTION 3 INSTALLATION.3 SECTION 4 KEY DESCRIPTIONS 5 SECTION 5 DISPLAYS.6 SECTION

More information

Vibration-Resistant Weighing Indicator

Vibration-Resistant Weighing Indicator Vibration-Resistant Weighing Indicator Powerful vibration-cancelling function (High Performance Digital Filter) High speed sampling (100 times/second)/high accuracy Circuits equipped with powerful noise

More information

GE Infrastructure Sensing. Druck DPI 832. Electrical loop calibrator User manual - K393

GE Infrastructure Sensing. Druck DPI 832. Electrical loop calibrator User manual - K393 GE Infrastructure Sensing Druck DPI 832 Electrical loop calibrator User manual - K393 A1 B1 10 1 A 2 9 A 3 8 2 3 7 6 11 4 5 B1 12 A2 13 15 14 A3 19 18 17 16 27 20 21 22 23 26 24 25 K393 Issue 1 Table of

More information

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved

Installation / Operator / Service Manual. Bench Scales Revision 6 07/ by Fairbanks Scales Inc. All rights reserved Installation / Operator / Service Manual Bench Scales 2005-2010 by Fairbanks Scales Inc. All rights reserved 50778 Revision 6 07/10 Amendment Record 50778 Manufactured by Fairbanks Scales Inc. 821 Locust

More information

Model MS Operation Manual. Manual: xxxxxx Issue:xx

Model MS Operation Manual. Manual: xxxxxx Issue:xx Model MS-1000 Operation Manual Manual: xxxxxx Issue:xx Avery Weigh-Tronix, LLC. All rights reserved. The information contained herein is the property of Avery Weigh-Tronix and is supplied without liability

More information

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller.

Warning. Warning. Warning. Pay Attention to Static Electricity. Ask professional personnel to debug, detect. and repair controller. Warning Ask professional personnel to debug, detect and repair controller. Warning Warning Please keep good grounding of controller. In electrical connection of controller, please cut off the power supply

More information

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance.

1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance. 1. INTRODUCTION This manual contains installation, operation and maintenance instructions. Please read the manual completely before using the balance. 1.1 Safety Precautions Please follow these safety

More information

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD

AD-8923-BCD. Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD AD-8923-BCD Remote Controller (BCD) INSTRUCTION MANUAL 1WMPD4002137 2010 A&D Company, Limited. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, or translated

More information

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice.

Digital Bench Scale. Revision 1.2 September 14, 2000 Contents subject to change without notice. Digital Bench Scale Revision 1.2 September 14, 2000 Contents subject to change without notice. Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-0529 Tel (507) 238-8702

More information

The ultimate multi-purpose digital scale Ideal for letters, parcels and large boxes

The ultimate multi-purpose digital scale Ideal for letters, parcels and large boxes The ultimate multi-purpose digital scale Ideal for letters, parcels and large boxes 0 ON/OFF UNIT HOLD ZERO HOLD INSTRUCTION MANUAL CONTENTS 03 Safety Precautions -Warnings -Cautions -Battery Installation

More information

Sartorius Research. R 160 P Electronic Semi-Microbalance

Sartorius Research. R 160 P Electronic Semi-Microbalance Sartorius Research. R 160 P Electronic Semi-Microbalance Installation and Operating Instructions 1 Power receptacle, fuse, 8 Level indicator voltage selector 9 ON/OFF key 2 Menu access switch 10 Print

More information

This document hosted by: 10. OPTIONS

This document hosted by:  10. OPTIONS This document hosted by: www.oldwillknottscales.com 10. OPTIONS The following options are available for the FG series: OP-23 (FG-23) RS-232C serial interface OP-24 (FG-24) RS-232C serial interface and

More information

BW 2050 Manual. Weltech Interna onal Limited INTRODUCTION

BW 2050 Manual. Weltech Interna onal Limited INTRODUCTION INTRODUCTION Weltech Interna onal Limited The BW 2050 has been designed to give the operator complete flexibility for manual live bird weighing. The BW 2050 is ba ery operated and will weigh for up to

More information

Model DS100 Scale Indicator

Model DS100 Scale Indicator Model DS100 Scale Indicator Operator s Manual Doran Scales, Inc. 1315 Paramount Pkwy Batavia, IL 60510 1 800 262 6844 www.doranscales.com MAN0247 Manual Revision 0.1 i Section 1. Unpacking and Installation...1

More information

EDGE. Digital Kitchen Scale. 11lb x 0.1oz 5000g x 1g

EDGE. Digital Kitchen Scale. 11lb x 0.1oz 5000g x 1g EDGE Digital Kitchen Scale 11lb x 0.1oz 5000g x 1g EDGE Manual Thank you for purchasing the American Weigh EDGE Digital Kitchen Scale. Please read all operating instructions carefully before use. Scales

More information

Precision Balance W3200 Series Operating Manual

Precision Balance W3200 Series Operating Manual Precision Balance W3200 Series Operating Manual Version 9-19-16 1 2 CONTENTS 1. INTRODUCTION. 4 2. INSTALLATION... 4 2-1. Unpacking.... 5 2-2. Specifications.... 5 2-3. Environmental Requirements... 5

More information

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: 805HP Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com TABLE OF CONTENTS 1. Introduction and Product Features 3 2.

More information

S2 USER MANUAL. AL Manual 110ES WL S2 En 103

S2 USER MANUAL.  AL Manual 110ES WL S2 En 103 S2 USER MANUAL http://www.anyloadgroup.com Page 1 of 15 TABLE OF CONTENT 1 Introduction 3 1.1 Standard Features.....3 1.2 Specifications..4 1.3 Display..4 1.4 Keyboard...5 1.5 Battery..6 2 General Configuration.6

More information

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6.

Mounting Dimensions / Viewing 2 Mounting Options 3. Wiring Configuration 4. Quick Set up Procedure 5. Changing Intensity 6. Section Mounting Dimensions / Viewing 2 Mounting Options 3 Section 2 Wiring Configuration 4 Section 3 Quick Set up Procedure 5 Section 4 Changing Intensity 6 Section 5 Option Summary 7 Section 6 Option

More information

21e. Multi-Function Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT

21e. Multi-Function Indicator. Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT 21e Multi-Function Indicator Operation Manual (Full Version) PLEASE READ THIS MANUAL VERY CAREFULLY BEFORE OPERATING THIS INSTRUMENT Specifications subject to change without prior notice V128 October 2018

More information

CONTENTS. PRECAUTIONS... 4 PREFACE... 6 OVERALL VIEW... 6 DISPLAY & KEYBOARD... 7 OPERATIONS I. Programming Mode II. Sales Mode...

CONTENTS. PRECAUTIONS... 4 PREFACE... 6 OVERALL VIEW... 6 DISPLAY & KEYBOARD... 7 OPERATIONS I. Programming Mode II. Sales Mode... 2 e CONTENTS PRECAUTIONS... 4 PREFACE... 6 OVERALL VIEW... 6 DISPLAY & KEYBOARD... 7 OPERATIONS... 11 I. Programming Mode... 11 Chapter 1. Basic Operation... 12 Chapter 2. PLU Saving & Calling-up... 15

More information

M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES

M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES M-610 USER MANUAL PLEASE TAKE THE TIME TO READ THESE INSTRUCTIONS BEFORE STARTING TO USE THE SCALES TABLE OF CONTENTS INTRODUCTION. 2 POWER SUPPLY. 4 INSTRUCTION FOR REPLACING BATTERIES 5 SPECIFICATIONS..

More information

7561-PSD Manual Portable Battery Powered Indicator

7561-PSD Manual Portable Battery Powered Indicator 7561-PSD Manual Portable Battery Powered Indicator Lebow Products Inc. 1728 Maplelawn Drive P.O. Box 1089 Troy, Michigan 48084-1089 (800) 803-1164 Phone: (248) 643-0220 FAX: (248) 643-0259 Visit our web

More information

uline.com OVERVIEW OF CONTROLS. k g. Tare Menu. Exit. Print. Units PRINT

uline.com OVERVIEW OF CONTROLS. k g. Tare Menu. Exit. Print. Units PRINT 3000SERIES 0 CO On/Zero Off Yes Print Units No PCS NET TARE Function Mode Back Tare Menu Exit k g π H-2587, H-4594 OHAUS DEFENDER 3000 DIGITAL SCALE 1-800-295-5510 uline.com OVERVIEW OF CONTROLS CONTROL

More information

Oxford E Series. Instruction Manual

Oxford E Series. Instruction Manual Oxford E Series Instruction Manual E Series User Manual Contents. Introduction................................................................... Unpacking...................................................................

More information

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual

MPB SERIES Electronic Balances. r1 v1.09. Operation Manual MPB SERIES Electronic Balances r1 v1.09 Operation Manual CONTENT 1. Introduction 1 2. Key and display 2.1 Key Function 1 2.2 Display 1 3. Operation 3.1 Before use 2 3.2 Zeroing the display 2 3.3 Taring

More information

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website:

805HP. Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: 805HP Handheld Digital Weight Indicator Operations Manual (V1612) Anyload Transducer Co. Ltd Website: www.anyload.com Email: info@anyload.com TABLE OF CONTENTS 1. Introduction and Product Features 3 2.

More information

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale

FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale NORmal USE Buttons ON/OFF hold UNIT ZERO/TaRE Indicators FCS-30/60/150 kg (3 DIFFRENT SCALES) Shipping scale Starts and turns off scale hold-funktion holds the value up to 2 minutes. Switches between units

More information

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice.

Digital Bench Scale. Revision 1.2 August 24, Contents subject to change without notice. Digital Bench Scale Revision 1. August 4, 000 Contents subject to change without notice. Salter Brecknell Weighing Products 1000 Armstrong Drive Fairmont, MN 56031 Tel (800) 637-059 Tel (507) 38-870 Fax

More information

Nimbus NBL Series (P.N , Revision 3.00, Effective Aug 2017)

Nimbus NBL Series (P.N , Revision 3.00, Effective Aug 2017) Adam Equipment Nimbus NBL Series (P.N. 3016612481, Revision 3.00, Effective Aug 2017) Operating Manual For internal ( i ), external ( e ) calibration ( p ) pillar models Software rev.: V3.1145 & above

More information

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5

CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5 CONTENTS INTRODUCTION 1 INSTALLATION 1 KEYS 3 MAXIMUM DISPLAY & DISPLAY RESOLUTION 4 BATTERY STATUS INDICATION 5 POWER ON SETUP 5 COUNT VALUE DISPLAY 6 WEIGHING UNIT SETUP 7 INITIAL UNIT SETUP 7 AUTOMATIC

More information

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT

IGB Series. Operation Manual. Platform Scale. Kg/Lb Specification IMPORTANT Platform Scale IGX/ Kg/Lb Specification Operation Manual IMPORTANT Do not carry out installation, operation, service, or maintenance until thoroughly understanding the contents of this manual. Keep this

More information

MDW 250L PHYSICIAN SCALE with BMI

MDW 250L PHYSICIAN SCALE with BMI Adam Equipment MDW 250L PHYSICIAN SCALE with BMI ADAM EQUIPMENT CO. LTD. p.n. 700660146 Rev. D, December 2010 Adam Equipment Company 2010 Adam Equipment Company 2010 Page 1 CONTENTS 1.0 INTRODUCTION...4

More information

STANDARD OPERATING PROCEDURE AA SERIES AA-160 PRECISION BALANCE

STANDARD OPERATING PROCEDURE AA SERIES AA-160 PRECISION BALANCE Table of Contents Page 1. Scope 2 2. Objective 2 3. Definitions 2 4. Responsibility 3 5. Procedure 3 6. Precautions 12 7. References 12 8. Appendices 12 9. Revision History 12 Original Authorised Copy

More information