8125 Series Terminal Boxes
|
|
- Jasmine Norton
- 5 years ago
- Views:
Transcription
1 8 Series Terminal oxes TERMINTION Ready-Term 8 Terminal oxes Features: Pre-onfigured with terminals mounted Materials: Stainless Steel or arbon Steel Six enclosure sizes with different depths For power and control circuits For I.S. circuits with blue terminals Entry hardware optional Field installation possible INNOVTIVE EXPLOSION PROTETION by R. STHL //0
2 TERMINTION Ready-Term 8 Terminal oxes PRE-ONFIGURE STINLESS N RON STEEL TERMINL OXES WITH PHOENIX TERMINLS Ordering Information TERM. QTY. WIRE RNGE WG. TERM. SIZE mm2 MX. MPS. PER TERM. TLOG NUMER FOR POWER & ONTROL IRUITS GRN. WIRE ON- NETIONS TLOG NUMER FOR INTRINSILLY SFE IRUITS P WIRE ONNE- TIONS ENLOSURE ORIENTTION LSSIFITIONS OF 8/ NE- lass I, Zones & 2 Ex e II T6/T lass I, ivision 2, Groups,,, lass II, ivision 2, Groups F,G lass III NEM rating stainless steel version 3, 4 & 4X; IP66, carbon steel version, painted 3 & 4; IP66, File No. E /4-2P-* 8 8/4-2P- * /-2P-8 8/-2P-8-4 8/-2P-0 8/-2P-0 E- lass I, Zones & 2 Ex e II T6/T lass I, ivision 2, Groups,,, lass II, ivisions & 2, Groups E,F,G lass III 9-6 8/-2P /6-2P- 8/6-2P- S ENLOSURES stainless steel version Type 3, 4 & 4X; IP66 carbon steel version, painted Type 3 & 4; IP66 File No. LR /6-2P-0 8/6-2P /6-2P /7-2P- 8/7-2P- II 2G EEx e II T6/T, Zones & 2 II 2G EEx ia/ib II, II, II T6 PT 00 TEX /7-2P-036 8/7-2P-036 II 2 IP6X, T, T9 or T LIE 03 TEX 6-6 8/7-2P Max. Voltage 0 / mbient Temperature Range: + (+4 F) Max. T6 + (+ F) Max. T ( 4 F) Min. Special mbient Temperature Range:* + (+ F) Max. ( 8 F) Min. * onsult Factory FETURES The Ready-Term 8 Series of terminal boxes are made of 3 stainless sheet steel or painted carbon steel. They offer a one-source solution to the time-consuming process of providing ready to install terminal boxes for hazardous locations. With its single part number solution, the Ready-Term 8 Series eliminates the inconvenience of purchasing the enclosure and individual parts. This Series is supplied with the indicated quantity of individually numbered terminals for each size of enclosure, fully certified and ready to be installed. To Select Painted Steel Enclosures change 2 to To Select Weidmuller Terminals change P to W For dimensional data see page *With Phoenix terminals only onduit Hubs Mounted for 8 Series Enclosures (Ex e) HU, NPT THRE SIZE TLOG NUMER /2" 86/-0-NE m 3/4" 86/-02-NE m " 86/-03-NE m /4" 86/-04-NE m /2" 86/-0-NE m 2" 86/-06-NE m 2 /2" 86/-07-NE m 3" 86/-08-NE m INNOVTIVE EXPLOSION PROTETION by R. STHL
3 Ready-Term 8 Terminal oxes TERMINTION PRE-ONFIGURE STINLESS N RON STEEL TERMINL OXES WITH PHOENIX TERMINLS Ordering Information TERM. QTY. WIRE RNGE WG. TERM. SIZE mm 2 MX. MPS. PER TERM. TLOG NUMER POWER FOR POWER & ONTROL & GRN. IR- WIRE ON- ONTROL IRUITS UITS NETIONS TLOG NUMER FOR INTRINSILLY SFE IRUITS P WIRE ON - NETIONS ENLOSURE ORIENTTION /73-2P- 8/73-2P /73-2P-036 8/73-2P /73-2P LSSIFITIONS of 8/ NE- lass I, Zones & 2 Ex e II T6/T lass I, ivision 2, Groups,,, lass II, ivision 2, Groups F,G lass III NEM Ratings: See Page File No. E /73-2P /0 0 8/73-2P-/ /83-2P- 36 8/83-2P- 36 E- lass I, Zones & 2 Ex e II T6/T lass I, ivision 2, Groups,,, lass II, ivisions & 2, Groups E,F,G lass III S ENLOSURES: See Page File No. LR /83-2P /83-2P /83-2P /83-2P /0 0 8/83-2P-/ /83-2P /83-2P /83-2P /83-2P /83-2P /93-2P /93-2P /93-2P /93-2P /93-2P /93-2P /0 0 8/93-2P-/ /93-2P- 72 8/93-2P /93-2P /93-2P /93-2P To Select Painted Steel Enclosures change 2 to To Select Weidmuller Terminals change P to W For dimensional data see page II 2G EEx e II T6/T, Zones & 2 II 2G EEx ia/ib II, II, II T6 PT 00 TEX ust approval, see page Max. Voltage 0 / mbient Temperature Range: See Page In addition to the various North merican applications, this Series is PT certified for use in Zones and 2. The design conforms to ENELE EN 0 and IE and many others. onsult factory. PPLITION Typical applications include junction boxes for petrochemical plants, waste treatment facilities, oil refineries and other major industrial plants. s a product with certifications recognized globally, the Ready-Term 8 Series is well suited for original equipment manufacturers who market throughout the world. The 8/ Series of terminal boxes is intended for use on circuits designed for power and motor control applications. The 8/2 Series is intended for use with intrinsically safe circuits. These enclosures are outfitted with blue terminals to provide an indication to field personnel that the circuits are intrinsically safe and should not be confused with nonintrinsically safe circuits. These enclosures make it necessary for the metal entry hardware to be bonded to the ground system. Use the suitable 86/ conduit hubs specified in the hub table on page. ustom enclosures can be configured upon request. The following modifications are available: Stainless Steel hinges for right or left side (specify) onduit hubs 86/ (specify) able glands (specify) lose-up plugs (specify) Flange plates (specify) Screw-Type Terminals up to 0MM age lamp Terminals up to 8WG INNOVTIVE EXPLOSION PROTETION by R. STHL
4 TERMINTION 8 Series Terminal oxes INSTLLTION OF ENTRY HRWRE Method : Enclosures with flange plates using threaded openings through the flange plate and standard locknuts. Flange plates must be connected to the internal grounding system using jumper wires The 8 Series of metallic terminal boxes are available with factory installed conduit hubs for conduit installation or with cable glands for cable installation. pproved and suitable for the location entry hardware can also be field installed. These enclosures make it necessary for the metal cable glands or conduit hubs to be bonded to the ground system. This can be accomplished by installing enclosures with flange plates according to Method (shown on the upper half of this page), or enclosures without flange plates according to Method 2 (shown on the lower half of this page). Method 2: Enclosures without flange plates using a hole through the enclosure with grounding locknut Table for max. numbers of entry openings either installed with conduit hubs 86/ (see page 8) or TM cable glands. UTION: The max. possible number of entries which can be installed on the sides of the enclosures depends on the number of terminal columns installed. With horizontally installed columns, there are no side entries possible or only limited, depending on enclosure size. With vertically installed columns there are no bottom or top entries possible, or only limited, depending on enclosure size. These locknuts must be bonded between each other and to the grounding system using a jumper wire. fter the entry hardware is installed, connect the appropriate conduit or cable. INNOVTIVE EXPLOSION PROTETION by R. STHL
5 8 Series Terminal oxes TERMINTION INSTLLTION OF 86/ ONUIT HUS OR TM LE GLNS 8/.04 8/.0 8/.06 8/.063 Size / / / / /2" /4" 3-2 " /4" /2" " /2" " Size / / / / /2" /4" " /4" /2" " /2" " Size / / / / /2" /4" " /4" /2" " /2" " Size / / / / /2" /4" " /4" 3 4 -/2" 2 3 2" 2 2-/2" 2 3" - - 8/.07 8/.073 8/.08 8/.083 Size Size Size Size / / / / / / / / / / / / / / / / /2" /2" 6 4 /2" /2" 3/4" /4" 4 8 3/4" /4" 8 8 " " " - - " 4 4 -/4" /4" /4" /4" /2" /2" 2 3 -/2" /2" 3 3 2" " 4 2 2" " /2" /2" /2" /2" " " " " /.08 8/.09 8/.093 8/.09 Size Size Size Size / / / / / / / / / / / / / / / / /2" /2" /2" /2" /4" 8 8 3/4" /4" 8 3/4" 8 " 4 4 " - - " 4 8 " /4" /4" /4" /4" /2" /2" /2" 3 6 -/2" " 2 2 2" " " /2" /2" /2" /2" " " " " INNOVTIVE EXPLOSION PROTETION by R. STHL
6 TERMINTION 8 Series Terminal oxes PRTS N ESSORIES Optional: 3 stainless steel cover hinges captive 3 stainless steel cover screws ESIGNTION ILLUSTRTION ESRIPTION TLOG NUMER Flange " x 2.7" x 0.2" Plate (8 x 68 x mm) Size carbon steel stainless steel an be fitted in Enclosures Sides 8/ 0 /// 8/ 06 /// 8/ 07 /// 8/ S7 / 8/ 08 /// Flange." x " x 0.2" Plate (6 x 8 x mm) Size 2 carbon steel stainless steel an be fitted in Enclosures Sides 8/ 063 / 8/ 073 / 8/ 083;/ 08 /// 8/ 093;/ 09 /// Flange " x " x 0.2" Plate (6 x 6 x mm) Size 3 carbon steel stainless steel an be fitted in Enclosures Sides 8/ 073 / Flange 3.86" x 6." x 0.2" Plate (2 x x mm) Size 4 carbon steel stainless steel an be fitted in Enclosures Sides 8/ 08 /// 8/ 09 /// Optional: flange plates oupling Frames over Hinges Frame Sizes " x 2.68" (68 mm x 68 mm).04" x 2.68" (8 mm x 68 mm) 2." x 4.96" (6 mm x 6 mm) " x 4.96" (6 mm x 6 mm) " x 6." (2 mm x mm) 8 for retrofitting to enclosure Kit consists of: 2 hinges hinges Entry Hubs 86/ mounted (see page and 8) 86/ part only (see page I) INNOVTIVE EXPLOSION PROTETION by R. STHL
7 8 Series Terminal oxes TERMINTION IMENSIONS 6.9" 6.mm." 36.mm.98" mm 6.9" 6.mm." 36.mm.98" mm.98" mm 7.7" 9mm 9.3" 2mm 6.63" 8.mm 6" 2.mm 4.9".mm." 7mm 7.00" 8.mm 8." 2.mm 6.9" 6.mm." 7mm 9" 2mm 8.4" 3mm 6.9" 6.mm." 7mm 8/ 04.".mm.39" mm 3.8" 9mm 8/ 0.".mm mm.39" 3.8" 9mm 8/ 06.".mm.39" mm d." 7mm 6.9" 6.mm 8." 2.mm 9.00" 8.mm." 7mm." 3mm.9" 396mm." 4mm." 3mm.98" mm." 3mm.".mm d.39" mm." 3mm.98" mm." 3mm.".mm d.39" mm 8/ 07 8/ 08 vailable Enclosure epth (d)." 7mm Enclosure 3 6 Sizes 3.8".9" 7.48" 9.06" 9mm 0mm 0mm 2mm 8/ 04 x / 0 x / 06 x x - - 8/ 07 x x - - 8/ 08 x x x x 8/ 09 8/ 09 x x x - 0." mm." 3mm.9" 396mm." 4mm.0" 687mm.62" 7mm.98" mm.".mm d.39" mm Flange option: dd to overall dimensions. INNOVTIVE EXPLOSION PROTETION by R. STHL
8 TERMINTION 8 / Series Terminal oxes Terminal ata Terminal Type solid/stranded Max. Max. Torque Phoenix wire range voltage, V mps lb-in Electrical apacity Tables (only applicable for lass I, Zone Ex e) In lass I, Zone hazardous (classified) areas, heat produced by current in the wire inside an enclosure is a concern. Therefore, the continuous current of each current carrying conductor, the quantity and the size of the conductors inside a terminal enclosure needs to be limited. For each enclosure size, there is one table which shows the permissible values for that particular terminal enclosure. How to use the electrical capacity tables: etermine the enclosure type you are dealing with. Reference the applicable electrical capacity table printed on pages -. In the white area of the table the permitted numbers of current carrying conductors inside the enclosure are indicated (in and out counts two wires) depending on wire size and continuous current. In the green shaded area of the table additional conductors/terminals are permitted up to the space limit of the enclosure. (see catalog pages & ) In the area with red diagonal lines of the table no conductors/terminals are permitted. Jumper links and ground wires can be neglected, in calculating the number of wires. These can be added whenever necessary. UK 2. N UK 3 N UK N UK -Twin UK 6 N -8 0 UK N UK N UK 8-/ Terminal Type Weidmueller WU WU WU WU WU -6 0 WU -2 0 WU 6-2/ WU WFF WFF Terminal Type Wago N/ N/ N/ N/ N/ EXMPLE: Enclosure type: 8/6-2P-0(see page ). The maximum physical quantity of terminals - WG for this enclosure is. Reference the table 8/6 on page, you will find that 8 wires WG with mps continuous current is the thermal limit of this enclosure. onclusion: To terminate 8 wires 9 terminals are needed, terminating two wires per terminal only. The remaining terminals (- 9 =) can be used for low amperage circuits in the green shaded area of the table. Jumper links and ground wires can be neglected. Mixed circuits of different wire sizes and current values are possible by applying the table values proportionally i.e. enclosure table 8/6. Wire Size WG urrent mps Number of urrent arrying onductors Permissible actual Proportion % 8 9 % 0% max. INNOVTIVE EXPLOSION PROTETION by R. STHL
9 8 / Series Terminal oxes TERMINTION ELETRIL PITY TLES, PPLILE FOR LSS I, ZONE ONLY Enclosure 8/4 Enclosure 8/ urrent mps Wire size WG 7 urrent mps Wire size WG Enclosure 8/6 Enclosure 8/63 urrent mps 68 Wire size WG urrent mps 89 Wire size WG INNOVTIVE EXPLOSION PROTETION by R. STHL
10 TERMINTION 8 / Series Terminal oxes ELETRIL PITY TLES, PPLILE FOR LSS I, ZONE ONLY Enclosure 8/73 urrent mps Enclosures 8/7 Wire size WG urrent mps Wire size WG / /0 3 Enclosures 8/7 urrent mps Wire size WG/MM / /0 3/0 4/ urrent mps Enclosure 8/8 Wire size WG / INNOVTIVE EXPLOSION PROTETION by R. STHL
11 8 / Series Terminal oxes TERMINTION ELETRIL PITY TLES, PPLILE FOR LSS I, ZONE ONLY Enclosure 8/83 urrent mps Wire size WG/MM / /0 3/0 8 4/0 0 Enclosure 8/8 urrent mps Enclosure 8/9 Wire size WG /0 0 3 urrent mps Wire size WG/MM / /0 3/0 4/0 0 INNOVTIVE EXPLOSION PROTETION by R. STHL
12 TERMINTION 8 / Series Terminal oxes ELETRIL PITY TLES, PPLILE FOR LSS I, ZONE ONLY Enclosure 8/93 urrent mps Wire size WG/MM / /0 3/0 4/ Enclosure 8/9 urrent mps Wire size WG/MM / /0 4 3/0 4/ INNOVTIVE EXPLOSION PROTETION by R. STHL
8125 Series Terminal Boxes
8125 Series Terminal oxes TERMINTION Ready-Term 8125 Terminal oxes Features: Pre-onfigured with terminals mounted Materials: Stainless Steel or arbon Steel Six enclosure sizes with different depths For
More information8125 Series Terminal Boxes
8125 Series Terminal oxes TERMINTION Ready-Term 8125 Terminal oxes Features: 14 TERMINTION Ready-Term 8125 Terminal oxes PRE-ONFIGURE STINLESS N RON STEEL TERMINL OXES WITH PHOENIX TERMINLS LSSIFITIONS
More informationRT2Y Compact temperature switch intrinsic safety
ompact temperature switch intrinsic safety Main Features Excellent repeatability Fix dead band for control and alarm Resistant to accidental overtemperature Intrinsic safety Hazardous area 0, 1, 2 pplications
More informationRT2E Compact temperature switch Explosion proof
ompact temperature switch Explosion proof Main Features Excellent repeatability Dead band adjustment for regulation Fix dead band for control and alarm Light weight Explosion proof Hazardous areas 1, 2,
More information3/2 Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G1/2, 1/2 NPT or flanged with NAMUR interface
9805 / Directional control valves Indirect controlled solenoid operated poppet valves Internal thread G/, / NPT or flanged with NMUR interface Main application: single operated process actuators TÜV-approval
More informationLevel instruments. Continuous level measurement - Radar transmitters SITRANS LR560. 5/2 Siemens FI Overview.
Overview onfiguration 2-wire, 78 GHz FMW radar level transmitter for continuous monitoring of solids in silos to a range of 100 m (329 ft). enefits rugged stainless steel design for industrial applications
More informationControl Stations & Switches: Switches, Circuit Breakers and "Break Glass" Call Points SWE Series: 16 and 20 A Switches Increased Safety
SWE Series: 16 and 2 A Switches Increased Safety 16 A Version - Type 1 16 A Version - Type 2 2 A Version Compliance Data: ATEX - IEC: Zone 1 & 2, 21 & 22 ATEX IEC CE Ex de IIC T6 Ex td A21 T8 C IP66 -
More informationOperating Instructions
Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on
More informationTerminal Boxes Series 8118
> Enclosure made of glass fibre reinforced polyester resin > sizes available > Terminals and cable glands fitted to order > Enclosure design with integrated metal bracket for metal cable glands. > Degree
More informationBulletin 1494H Heavy Duty Safety Switches
ulletin H Heavy uty Safety isconnect Switches Product Overview/Product Selection Fusible and Non-Fusible Type ulletin H Heavy uty Safety Switches switch ratings Type, R, or enclosures V: -phase, -phase,
More informationEJB Junction Boxes Dimensions Pg. 132
6F EJB Junction Boxes Dimensions Pg. 132 Application: EJB junction boxes are used in threaded rigid conduit systems in hazardous areas: As a junction or pull box To provide enclosures for splices and branch
More informationSITRANS F flowmeters SITRANS F US. Flowmeter SONO 3300/FUS060 4/177. Technical specifications. Overview
Overview The combination of sensor SONO 3300 sensor and FUS060 transmitter is ideal for applications within the general industry. Measurements are independent of liquid temperature, density, pressure and
More informationStandard enclosure for Remote I/O Series 8150
> Stainless steel enclosure for installation in Zone 1 > Standard versions - available in max. 3 weeks > Prepared for the installation of IS1+ Remote I/O > For up to 112 analog or 224 digital signals >
More informationZones 1&2; 21&22. Distribution Boxes and Empty Enclosures. Empty Enclosures. BXT Series Explosion-proof Enclosures (Ex d IIB) Catalogue number logic
istriution oxes nd XT Series Explosion-proof Enclosures (Ex d II) Explosion protection to -ENELE -IE -NE n e used in Zone nd Zone Zone nd Zone lss I, Zone nd Zone lss I, ivision, Groups, Flmeproof enclosure
More informationOperating Manual / IEC. Explosion-Proofed Junction Boxes, Polyester. Wallücker Bahndamm 7 DE Kirchlengern
Operating Manual / IEC Explosion-Proofed Junction Boxes, Polyester Wallücker Bahndamm 7 DE- 32278 Kirchlengern Tel.: +49 5223 49107-0 Fax: +49 5223 49107-28 info@multi-box.com www.multi-box.com Contents
More informationSelection and Ordering data. Selection and Ordering data
Pointek CLS3, threaded version 7 M L 5 5-7 7777-77 7 Note: To select Standard or Digital CLS3 (with PROFIUS P), see final place holder under. Probe version (Threaded lengths include process thread.) Standard
More informationConveyor Belt Alignment Switches from IDEM
Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are
More informationPI-EX-ME-2NAM/COC-24VDC
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC
More informationPHOENIX CONTACT - 01/2008
Ex Basic Terminal Blocks for Intrinsically Safe Signals With Knife Disconnection and Test Connections INTERFACE Data Sheet 102957_00_en PHOENIX CONTACT - 01/2008 1 Description PI-EX-TB and PI-EX-TB/T Ex
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationJunction Boxes & Enclosures JBEP and ECEP Series: Undrilled Fiberglass Reinforced Polyester Enclosures Increased Safety
CSPe Type Small Version CAe Type Non-Hinged Version CAe Type Hinged Versions Compliance Data: ATEX - IECEx: Zone 1 & 1 & ATEX II GD IECEx CE Ex e II T6 to T Ex td A1 T75 C to T95 C Ex ia IIC; Ex ib IIC
More informationPHOENIX CONTACT - 12/2007
Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel
More informationPI-EX-ME-2NAM/COC-120VAC
PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description
More informationProviding flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2.
e X L i n k exlink 7-pole / 6-pole + PE for Zone 1 and Zone 21 Providing flexible power supply and signal connection there, where it is needed even in hazardous areas for the Zones 1and 2. The exlink 7
More informationViamaster LED Series Luminaires For ATEX and IECEx Governed Hazardous Locations
Applications For use in locations where: Flammable gases, vapors and dusts are present A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary Typical
More information/2 way indirect solenoid operated valves G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 / way indirect solenoid operated valves G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to SIL (IE 6508) dd-on manual
More informationViamaster LED Series Luminaires For NEC and CEC Governed Hazardous Locations
Class I, Division, Groups A, B, C, D Class I, Zone, Group IIC Class II, Division, Groups F, G Zone, Group IIIB Type R,, X Applications For use in locations where: Flammable gases, vapors and dusts are
More informationJunction Boxes & Enclosures JBEA and ECEA Series: Aluminum Enclosures Increased Safety
PCe Type CAe Type Compliance Data: ATEX - IEC: ATEX IEC CE Ex ia IIC; Ex ib IIC T6 to T2 Ex td A21 T0 C to T290 C Ex de IIC Operating Temperatures: -40 C to +55 C (CAe) -55 C to +60 C (PCe) 223 ATX Product
More informationIECEx Certificate of Conformity
INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.: IECEx BKI 07.0001X issue No.:1
More informationTRANSMITTERS. HygroFlex & HygroClip-EX. Applications. Highlights
HygroFlex & HygroClip-EX HygroFlex series may be used together with the intrinsically safe HygroClip-EX probes. The relative humidity and temperature can be displayed and output as analog signals. Calculated
More informationArlington Industries, Inc.
Intersystem ridges vailable in zinc or bronze. Provides reliable intersystem bonding between power and communication grounding systems. Comes with textured, paintable, white cover. Cover is UV rated plastic
More informationAllPro Hazardous/Corrosive Area Fluorescent
CSA - Class I Div. 2 - Groups A, B, C, & D CSA - Class I Zone 2 - Groups IIA, IIB & IIC CSA - Class II Div. 1 & 2 - Groups E, F & G CSA - 4X UL 844 - Class I Div. 2 - Groups A, B, C, & D UL 4X UL - Outdoor
More informationElectronic Corrector Mounting Kit for American Meter Rotary Meters.
Electronic Corrector Mounting Kit for American Meter Rotary Meters. Document: 900359 Revision: 1.02 December 2, 2005 Table of Contents SECTION ONE: INTRODUCTION SECTION TWO: MOUNTING KIT PARTS LIST SECTION
More informationEx Junction Boxes & Control Stations
www.fibox.com Ex Junction Boxes & Control Stations Fibox Oy Ab Keilaranta D Espoo, Finland Tel. + () Fax. + () E-mail: info@fibox.fi Homepage: www.fibox.com Fibox Ltd. -, Songdo-Dong, Yeonsu-Gu, Incheon,
More information98025 NAMUR 3/2 poppet valves electromagnetic actuated, indirectly controlled G 1/2, 1/2 NPT or flanged with NAMUR Interface
9805 NMUR / poppet valves electromagnetic actuated, indirectly controlled G /, / NPT or flanged with NMUR Interface Main application: single operated actuators for plants Valves for safety systems up to
More information5 Fieldbus Technology
5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically
More informationContinuous level measurement Ultrasonic transducers
Siemens G 2013 Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance
More informationContinuous level measurement Ultrasonic transducers
Siemens G 2012 Level measurement Overview EchoMax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 TABLE OF
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationInstallation & Operation Manual
Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas
More informationPHOENIX CONTACT - 05/2007
Ex Universal Module Carrier (Motherboard) for Accommodating 3-Wire Measuring Transducers, Intrinsically Safe, for a Maximum of 8 PI Ex Modules INTERFACE Data Sheet 103030_00_en PHOENIX CONTACT - 05/2007
More informationECHOMAX XPS-10 ULTRASONIC TRANSDUCER
Datasheet ECHOMX XPS-10 ULTRSONIC TRNSDUCER Supplied by.com Call us on + (0)118 916 920 Email info@27able.com Overview transducers use ultrasonic technology to measure level in a wide range of liquids
More informationSeries Panel Mounted Control Devices
E_Master2012.qxd:NEW_E_Master_temp.qxd 1/27/12 4:28 PM Page 1 Series Features: Suitable for hazardous and corrosive locations. Installation is easy and precise. Devices fit into a standard 30.5mm, 1.2"
More informationFEATURES DESCRIPTION
JUNCTION BOXES FEATURES Allows easy and safe device connections to the fieldbus (Fo u n d at i o n fieldbus TM, PROFIBUS) HART and even for standard instrumentation wiring 4-20 ma; Ideal for coupling sensors,
More informationMAXIMA+ Series Rotary Level Indicator
MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE
More informationINSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069
D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according
More informationBulletin 871C Plastic Face/Plastic Barrel or Nickel-Plated Brass Barrel
ulletin 87 Plastic Face/Plastic arrel or ickel-plated rass arrel ulletin 87 inductive proximity sensors are self-contained, general purpose, solid-state devices designed to sense the presence of ferrous
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationFloat switch For the process industry, lateral installation with external chamber Model ELS
Level measurement Float switch For the process industry, lateral installation with external chamber Model ELS KSR data sheet LM 30.03 for further approvals see page 2 Applications Mounting on engines,
More information4110 HART Level Encoder
4110 HART Level Encoder Precision encoding instrument for transmission of level measurement from mechanical float gauges Features Universal connection - mounts to all standard float gauges Low maintenance
More informationATX JBEA and ECEA Series Aluminum Enclosures Increased Safety
Applications Designed for use in Zone 1 or 2 areas where flammable gases or vapors are present either continuously or intermittently. Ideal for use in wet or corrosive atmospheres. Petroleum, chemical,
More informationApplications: Page 54. Waste treatment plants Marine loading terminals Pipeline pumping stations Solvent / cleaning areas
S - lass I Div. 1 - Groups & D S - lass I Div. 2 - Groups,, & D S - lass II Div. 1 & 2 - Groups E, F & G S - lass III UL 844 - lass I Div. 1 - Groups & D UL 844 - lass I Div. 2 - Groups,, & D UL 844 -
More informationATX FELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety
Zone and - and Applications For use in locations where: Hazardous areas are designated as Zone and and A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary
More informationTFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5
EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on
More informationDistributed Intrinsically Safe Fieldbus Applications
Application Note FB01-1 - Distributed Intrinsically Safe Fieldbus Applications Emerson Process Management DeltaV DCS System Pepperl+Fuchs June 2003 Application Note FB01-2 - c Pepperl+Fuchs Inc. All rights
More informationDräger Polytron 8200 Stationary gas detector (CatEx)
Dräger Polytron 8200 Stationary gas detector (CatEx) Quick, reliable and cost-effective detection of combustible gases and vapours in the ambient air: the microprocessor-based transmitter is the result
More informationContinuous level measurement Ultrasonic transducers
Siemens G 2012 Level Measurement Overview Echomax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing
More informationDMP 333 DMP 333. Industrial Pressure Transmitter For High Pressure. Stainless Steel Sensor. Pressure Transmitter. Industrial
DMP Industrial Pressure Transmitter For High Pressure Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.5 / 0. % FSO Industrial Pressure Transmitter DMP Nominal pressure
More informationSafety Instructions Cerabar S PMP71, PMP75
/00/EN/01.14 71249311 Products Solutions Services Safety Instructions PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex d IIC T* Gb TÜV 13.0902X Segurança TÜV INMETRO OCP 0004 Document: Safety
More informationFLEX Ex Spring Clamp Terminal Base
Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification
More informationEx e Command, Control and Signalling Operators SERIES M-0603, M-0604, M-0605, M-0612
TECHNICAL DATA SHEET NEW PRODUCT Rev. 6-03/2013 Ex e Command, Control and Signalling Operators SERIES M-0603, M-0604, M-0605, M-0612 Ex de Contact blocks SERIES M-0530, M-0531 1 - New Product Technical
More informationFloat Switches with Permanent Magnet For Vertical Installation Model RSM
Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring
More informationUniversal Tongue-Operated Safety Interlock Switch
Rev. 12.07 C R US Conforms to EN1088, EN292, EN60947-5-1, EN60204-1 UL and C-UL listed, B approved T12 Universal Tongue-Operated Safety Interlock Switch Strong and versatile the compact size of the strong,
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationSafety switches with separate actuator
A Safety switches with separate actuator Selection diagram VF KEYF VF KEYF1 VF KEYF2 VF KEYF3 VF KEYF VF KEYF ACTUATORS CONTACT BLOCKS 9 snap action overlapped FD FP FL FC 21 22 33 3 3NC 2NO+1NC 1NO+ CONDUIT
More informationSafety switches with separate actuator
4 Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD VF KEYD6 VF KEYD VF KEYD10 ACTUATORS CONTACT BLOCKS 6 snap action overlapped FR FX FK FW 0 1 4 NC NO+1NC
More information97105 NAMUR. Technical data. Ordering information and accessories See page 6 and 7
90 NAMUR /, / and / directional valves Actuation: electromagnetic Indirectly controlled soft seal spool valves Port size: G /, / NPT, G /, / NPT NAMUR-interface For single and double operated actuators
More informationTHERMASGARD TM 65. Immersion screw-in duct temperature measuring transducer, calibratable, with multi-range switching and active output TECHNICAL DATA
Patented quality product (Immersion sensor patent no. DE 10 2012 017 500.0) Calibratable temperature measuring transducer THERMASGARD with eight switchable measuring ranges, continuous linear output, enclosure
More informationExplosion Proof Junction Box - C1D1, C2D1 - (6) Circuit Terminal Strip - (6) Hubs - Backplate
Explosion Proof Junction Box - C1D1, C2D1 - (6) Circuit Terminal Strip - (6) Hubs - Backplate Part #: EPJ-6-TB The Larson Electronics EPJ-6-TB Explosion Proof Junction Box is designed for flammable work
More informationEFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS
EFP SERIES FLAMEPROOF ELECTRICAL CONNECTORS FOR HAZARDOUS ENVIRONMENTS Table of Contents EFP Introduction 4 Connector Features 5-7 Code Logic 8 Inline Plug w Threaded Entry Metric 9 Inline Plug w Mechanical
More informationTemperature process values at a glance
Temperature process values at a glance PERFORMANCE MADE SMARTER COMMUNIC AT I ON F OUND AT I O N TEMPERATURE I.S. INTERFACES COMMUNICATION INTERFACES MULTIFUNCTIONAL ISOLATION DISPLAY 7501 Field mounted
More informationSupplementary Components WirelessHART products
Overview SITRANS AW200 WirelessHART adapter The SITRANS AW200 WirelessHART adapter is a batterypowered communication component, which integrates HART and 4 to 20 ma field devices into a WirelessHART network.
More informationC 2 5 D N A A A
Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,
More informationKeystone OM3 - EPI-2 Local Interface Module Installation and Maintenance Instructions
Index 1 Optional module 3: Local Interface module... 1 2 Installation... 2 3 Description of OM3 Local Interface... 4 4 To locally operate the actuator... 4 5 OM3 wiring diagram... 5 6 Identification...
More informationINSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F
PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4
More informationKinetix 6000 Axis Module and Shunt Module
Installation Instructions Kinetix 6000 and Shunt Module Catalog Numbers 2094-AMxx, 2094-BMxx 2094-AMxx-S, 2094-BMxx-S 2094-BSP2 Topic Page About This Publication 1 Important User Information 2 Before You
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A
More informationDo not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.
D460/D470 Series - ATEX certified position transmitter nnnn II 2 GD ITS 11 ATEX 17431X Ex d IIC T* Gb Tamb -*ºC to +*ºC Ex tb IIIC T* Db Tamb -*ºC to +*ºC IP6X Ambient variation -60 C to +110 C (T4/T130
More informationLevel-Lance Model 5400A
Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing
More informationSeries 3730 Electropneumatic Positioner Type
Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm
More informationLevel measurement. Applications. Special features. Description
Level measurement Optoelectronic level switch Model OLS-S, for the process industry (with Ex i approval: KSR-OPTO.21*06XX) Model OSA-S, switching amplifier (with Ex i approval: KSR-OPTO.2502.XX) KSR data
More informationPSSU/A2 Control Unit Installation Instructions
PSSU/ Unit Installation Instructions INTROUTION The PSSU/ control unit is designed to be used with Tapeswitch pressure sensitive sensors, such as ribbon switches, sensing edges, bumpers, and presence-sensing
More informationThis Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.
This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series
More informationLIQUID TIGHT INDUSTRIAL ENCLOSURES & ACCESSORIES
LIQUID TIGT INDUSTRIL ENLOSURES & ESSORIES PGE PGE INTERNTIONL PPROVLS ISO 900 ertified PGE PGE PGES & 00 PGE & East insdale ve. Suite D entennial, O 00, U.S. Phone: 0.0.9 FX: 0.0. EMail: info@hitechcontrols.com
More informationSignal processor MS96 for flow sensors MS96-11EX0-R/230VAC
MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment
More informationMX1 Reversible AC Motor Controller. Supplementary Wiring Examples
MX1 Reversible AC Motor Controller Supplementary Wiring Examples DANGER Electrocution Hazard! Ensure all power is disconnected before servicing or wiring. Install all electrical equipment and wiring in
More informationKINAX WT720 absolute, programmable angular postion transmitter
For industrial applications in rough environments KINAX WT720 is a robust, absolute angular position transmitter, which is particularly suited to applications in rough environments due to its unique capacitive
More informationHMT360 Series Intrinsically Safe Humidity and Temperature Transmitters
HMT360 Series Intrinsically Safe Humidity and Temperature Transmitters For operation in up to Zone 0 / 20 Features Measures humidity and temperature, outputs also dew point, mixing ratio, absolute humidity
More informationSolar Combiner Enclosure
Installation Instructions Solar Combiner Enclosure Catalog Numbers 1000-SB006, 1000-SB012 Topic Page Description 1 Important Safety Instructions 3 Nameplate Data 4 Planning for Installation 4 Install the
More information2.3. Ex-Linear light fittings for fluorescent lamps. ellk W 58 W / ellm W 36 W (Zone 1, 2, 21, 22)
.3 Ex-Linear light fittings for fluorescent lamps ellk 9 18 W 58 W / ellm 9 18 W 36 W (Zone 1,, 1, ) The classic lighting solution in hazardous areas The ellk 9 linear luminaire series for fluorescent
More informationSafety switches with separate actuator
Safety switches with separate actuator Selection diagram VF KEYD VF KEYD1 VF KEYD VF KEYD VF KEYD5 VF KEYD6 VF KEYD7 VF KEYD8 VF KEYD10 VF KEYD11 ACTUATORS FR FX FK FW 5 6 7 11 1 14 NC NC snap action snap
More informationMicro Motion Model 2200S 2-Wire Transmitter with MVD Technology
Product Data Sheet PS-001094, Rev. C September 2009 Micro Motion Model 2200S 2-Wire Transmitter with MVD Technology The Micro Motion Model 2200S 2-wire transmitter enables the use of reliable and accurate
More informationFELED Series Nonmetallic LED Luminaires Standard and Emergency Battery Back-Up, Increased Safety
Zone and - and Applications For use in locations where: Hazardous areas are designated as Zone and and A high degree of corrosion resistance is required Protection against dirt, water and moisture is necessary
More informationLinear Luminaire with LED Series 6012/5
> For use in Zones 1 & 2, 21 & 22 > Latest LED technology with a high luminous efficacy and a long service life > Extra flat version for low mounting depth > Powder-coated sheet-steel or brushed stainless
More informationTemperature Measurement SITRANS TS300
Siemens AG 018 For food, pharmaceuticals and biotechnology modular design Dimensional drawings Cable gland M1x1.5 for cable Ø 3... 6.5 (0.1... 0.6) Ø 60 (.36) Ø d = N + H 1 Ø 50.5 (1.99) U X H 1 N H Ø
More informationOperating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x
1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical
More informationCable Glands 757, BVE and 737 Series: Blanking Plugs, Adaptors and Reducers Increased Safety and Flameproof
757 Series Blanking Plugs 737 Series Adaptors and Reducers BVE Series Plastic Blanking Plugs & Sealing Washers Compliance Data: 757 Series Blanking Plugs: ATEX IECEx CE Ex d IIC or Ex e II Ex td A21 IP
More informationInductive dual sensor For rotary actuators NI4-DSU35TC-2Y1X2/S933
ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex zone 20 SIL2 as per IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position of rotary actuators Mounting
More informationApplications: Page 60. Chemical manufacturing / processing plants Paint manufacturing facilities Bulk truck terminals Refineries
CSA - Class I Div. 1 - Groups C & D CSA - Class I Div. 2 - Groups A, B, C & D CSA - Class II Div. 1 & 2 - Groups E, F & G CSA - Class III UL 844 - Class I Div. 1 - Groups C & D UL 844 - Class I Div. 2
More information