1 EMC PowerPath for Solaris Version Release Notes P/N Rev A02 June 2, 2006 These release notes contain supplemental information about EMC PowerPath, version Topics include: Product Description... 2 New Features and Changes... 2 Fixed Problems... 3 Environment and System Requirements... 4 Known Problems and Limitations Technical Notes Documentation Software Media, Organization, and Files Installation Troubleshooting and Getting Help

2 Product Description Product Description EMC PowerPath software is a server-resident, performance and application availability enhancing software solution. PowerPath combines multiple path I/O capabilities, automatic load balancing, and path failover functions into one integrated package. PowerPath supports servers, including cluster servers, connected to EMC Symmetrix, EMC CLARiiON, IBM ESS, Hitachi Lightning, Hitachi TagmaStore, HP StorageWorks xp, EVA, EMA, and MA storage systems. PowerPath supports Fibre Channel for both switched fabric and arbitrated loop environments. New Features and Changes PowerPath for Solaris adds support for the following new and enhanced features: EMC Invista network storage virtualization Note: PowerPath supports EMC Invista devices. A new class, INVISTA, lets you manage Invista devices using the powermt utility. Refer to the PowerPath 4.5 Product Guide for more information. Hitachi TagmaStore storage systems Note: The existing HITACHI class lets you manage Hitachi TagmaStore devices using the powermt utility. Refer to the PowerPath 4.5 Product Guide for more information. HP StorageWorks XP12000 storage systems Note: The existing HPXP class lets you manage HP StorageWorks XP12000 devices using the powermt utility. Refer to the PowerPath 4.5 Product Guide for more information. Discontinued Features in PowerPath This section includes information about discontinued features in PowerPath. EMC HighRoad Please be aware that the next release of PowerPath (post-4.5) will not include intrinsic disk protection for EMC HighRoad disks on Symmetrix storage systems. This is a change from PowerPath 4.5 and 2 EMC PowerPath for Solaris Version Release Notes

3 Fixed Problems earlier, in which disk protection for HighRoad disks is included in the PowerPath software. Effective with HighRoad version 4.0, disk protection for Symmetrix is included in the HighRoad software. If you are using PowerPath 4.5 or earlier with HighRoad 4.0 or earlier, you do not need to take any action at this time. In the future, if you want to upgrade to a version of PowerPath later than 4.5 (and you have HighRoad 3.2 or earlier), you will need to upgrade first to HighRoad version 4.0 or later before upgrading PowerPath. End-of-Life Announcement CLARiiON FC4700 As of PowerPath 4.5.0, EMC announced end-of-life (EOL) for CLARiiON FC4700 support. Effective with the release of PowerPath for Solaris, PowerPath will no longer support CLARiiON FC4700 storage systems. PowerPath Volume Manager Please be aware that EMC has announced end-of-life (EOL) for PowerPath Volume Manager (PPVM) functionality for Solaris, AIX and HP-UX environments. This is effective with the release of PowerPath 4.4 for Solaris in March 2005, the PowerPath 4.4 for AIX release, and PowerPath 4.5 for HP-UX. EMC has also announced its intention to end-of-service-life PPVM functionality for Solaris, AIX and HP-UX effective March Therefore, if you have any data on PPVM volumes, back up that data and destroy all PPVM volume groups before installing PowerPath or Fixed Problems Table 1 The following table shows resolved problems that were reported as known problems in earlier versions of PowerPath for Solaris. Resolved Problems in PowerPath Version 4.5.0: Solaris Description Found in Version Resolved in Version A PowerPath installation overwrites and changes host semaphore settings on Solaris servers. This is a remnant of PowerPath Volume Manager, for which end-of-life notification was announced with the release of PowerPath EMC PowerPath for Solaris Version Release Notes 3

4 Environment and System Requirements Table 1 Resolved Problems in PowerPath Version 4.5.0: Solaris (continued) Description Found in Version Resolved in Version After a double fault (for example, pulling two disks of out a RAID1 device) on a CLARiiON LUN, all other LUNs on the array show dead paths In pre-4.3 releases, powermt does not handle CLARiiON LUN names containing colons properly. In those earlier releases, powermt truncates CLARiiON LUN names at the point at which a colon is encountered. For example, the command powermt display dev=device all shows LUN 123:abc as LUN 123. In PowerPath 4.3.x (or later), this problem has been partially resolved. With this release, the command powermt load [file=older_file] fails to complete if the configuration file contains data for CLARiiON pseudo devices with colon-containing LUN names. This results in CLARiiON volumes and third-party volumes being set with default load balancing and failover policies , The powervxvm init script corrupts the VxVM rootdg created on external devices managed by PowerPath. The powervxvm init script now automatically protects disk groups (including rootdg), which prevents it from destroying any previously existing disk group. A warning appears near the end of the script to indicate which devices were not initialized Environment and System Requirements Before you install PowerPath, or whenever you make changes to the host or storage environment where PowerPath operates, consult the resources described in this section. These resources will help you configure an environment in which all components, including PowerPath, can operate optimally. EMC Support Matrix (all storage systems) The EMC Support Matrix provides detailed information about the hardware, software, and networked storage components that are tested and compatible with both EMC storage systems and third-party storage systems. (For information about third-party storage systems, see the chapter entitled Non-EMC Storage.) The EMC Support Matrix describes supported host models, operating system revisions, host bus adapters, and connectivity devices. The EMC Support Matrix, which is updated every month, is published at the Powerlink website: 4 EMC PowerPath for Solaris Version Release Notes

5 Environment and System Requirements The support matrix is available in two formats: The EMCLink E-Lab Navigator (formerly ESN Builder) link is a Web-based, searchable database configurator. The Download link (within E-Lab Navigator) lets you download the EMC Support Matrix as an Adobe.pdf file. EMC host connectivity guide (EMC storage systems only) The EMC host connectivity guides describe the features and setup procedures for host interfaces to EMC Symmetrix and CLARiiON systems. Host connectivity guides are updated quarterly and are published on the Powerlink website. Consult the Before You Install section of your installation and administration guide; the EMC Support Matrix; and, for CLARiiON or Symmetrix systems, the EMC Host Connectivity Guide for Sun Solaris before you install PowerPath. In addition, since changing any system component can change the way PowerPath manages storage paths, you should consult these resources before you undertake any of the following common system or network management tasks: Upgrade or change the host OS, or the host bus adapter. (Refer specifically to the Application Software chapter for your storage system model.) Change the model of the system that hosts PowerPath. Change or replace a host bus adapter type, or adapter cable on the system that hosts PowerPath. Change components (for example, switches) of your network configuration. Change the storage network zoning or device assignments. Change the array or storage system connected to the host. The information in the following sections is accurate at the time of publication. However, information about qualified hardware and software is revised and published monthly on the Powerlink website and quarterly in the EMC host connectivity guides. In the event of discrepancies, information in E-Lab Navigator, the EMC Support Matrix, or the host connectivity guide takes precedence over the information in these sections. EMC PowerPath for Solaris Version Release Notes 5

6 Environment and System Requirements Host Configuration Table 2 The following table shows the Solaris operating systems supported. Solaris: Supported Operating Systems Supported OS Sun patches required Sparc Solaris 7 (32 and 64 bit) (X6541 HBA only) (X1062A and X1065A HBAs only) Sparc Solaris 8 (32 and 64 bit) (X6541 HBA only) (X106A2 & X1065A HBAs only) Sparc Solaris 9 (32 and 64 bit) Sparc Solaris (X6767A and X6768A HBAs only) The following table shows minimum disk space requirements for Solaris. Table 3 Solaris: Disk Space Required File System or Directory Installation directory (the default is /opt) Root file system /usr /var Minimum Space Requirements 40 MB 16 MB 12 MB 1 MB 6 EMC PowerPath for Solaris Version Release Notes

7 Environment and System Requirements Supported HBAs: PowerPath for Solaris With Third-Party Storage Systems This section describes the HBA models and driver versions supported for PowerPath for Solaris with third-party storage systems. The section also describes changes to the default driver configuration files required by PowerPath for Solaris. Consult the EMC Support Matrix for HBA models and driver versions supported with Symmetrix and CLARiiON systems. Supported HBAs: IBM ESS, Hitachi Lightning, Hitachi TagmaStore, HP xp Systems PowerPath for Solaris has been tested and qualified for use with IBM ESS, Hitachi Lightning, Hitachi TagmaStore, and HP xp storage systems using the HBA models and driver versions shown in the following table. Table 4 Solaris: Supported HBAs IBM ESS, Hitachi Lightning, HP xp Systems Manufacturer Model Driver Versions Supported with Arrays IBM ESS Hitachi Lightning Hitachi TagmaStore HP xp Arrays Emulex LP8000 LP9000 LP9002LDC LP10000 EMC 5.02c EMC 6.01f LP9802 EMC 5.02c EMC 6.01f Supported HBAs: HP StorageWorks EVA, EMA, and MA Systems PowerPath for Solaris has been tested and qualified for use with HP StorageWorks EVA, EMA, and MA storage systems using the HBA models and driver versions shown in the following table. EMC PowerPath for Solaris Version Release Notes 7

8 Environment and System Requirements Note: HP requires installation of the Platform Kit on every host connected to these storage systems. The Platform Kit contains the drivers that are supported with the storage system. You can download the Platform Kit from the HP website. Table 5 Solaris: Supported HBAs HP StorageWorks EVA, EMA, MA systems Manufacturer Model Driver Versions QLogic QLA 2312 QLogic V4.11 SG-XPCIFC2-QF2 SUNWqlc SUNWqlcx SUNWqlcx Emulex LP8000 EMC 5.01e EMC 5.02c EMC 6.01f LP-9002 EMC 5.02c EMC 6.01f LP10000 EMC 6.01f 8 EMC PowerPath for Solaris Version Release Notes

9 Environment and System Requirements HBA Driver Settings The following table describes changes to the default driver configuration files required by PowerPath for Solaris with third-party storage systems. Table 6 Solaris: HBA Driver Settings Third-Party Storage Systems HBA Driver Parameter Default Setting PowerPath Setting Setting Required for Emulex automap 0 0 All third-party systems linkdown-tmo All third-party systems lun-queue-depth All third-party systems num-iocbs All third-party systems tgt-queue-depth All third-party systems no-device-delay 0 0 All third-party storage systems Heterogeneous Connections PowerPath for Solaris supports heterogeneous connections to different storage arrays from the same HBA only with the following HBA model numbers: Sun X6767A(SG-XPCI1FC-QF2) Sun X6768A (SG-XPCI2FC-QF2) LP8000 LP9002 LP9802 LP10000 Note: The heterogeneous connections allowed by third-party vendors may conflict with those allowed by EMC. In that case, the third-party vendor s requirements take precedence. EMC PowerPath for Solaris Version Release Notes 9

10 Environment and System Requirements Interoperability With VxVM on HP xp Arrays For PowerPath for Solaris to fully interoperate with VERITAS Volume Manager (VxVM) on third-party arrays, you must install the VERITAS Array Support Library (ASL) for your particular storage system after you install VxVM. You can download the ASL from the VERITAS website. Storage Array Configuration Symmetrix Storage Systems Before you install PowerPath, set up connections between a storage system and a host. Refer to the EMC Host Connectivity Guide for Sun Solaris for information on setting up connections for Symmetrix and CLARiiON systems. For information on setting up connections for third-party storage systems, refer to your vendor s documentation. The following table shows requirements and specifications for a PowerPath host connected to a Symmetrix system: maximum number of paths per logical device, Enginuity microcode levels supported, and support for booting from a Symmetrix device. Microcode versions tested Paths per device Boot support 5x67, 5x68, 5x69, 5x70, 5x71 32 Solaris 7, 8, 9, 10 Note: For information about LUN configuration and limits see the EMC host connectivity guide, available on the Powerlink website. Once a host and Symmetrix system are properly configured, you can install or upgrade PowerPath. See the PowerPath for Solaris Installation and Administration Guide for installation details. CLARiiON Storage Systems PowerPath installation is an integral part of a CLARiiON setup and configuration procedure. To properly install PowerPath on a host with a CLARiiON array, refer to the EMC Installation Roadmap for CX-Series and FC-Series Storage Systems. There you will find step-by-step instructions for installing PowerPath and other CLARiiON software. To obtain the latest versions of CLARiiON CX-series documentation, log in to the Powerlink website ( Then click Support > Document Library. CLARiiON AX100-Series installation, planning, and troubleshooting documents are located on the AX100 support website. For information on accessing the site, refer to the support documentation that shipped with your storage system. Refer only to these 10 EMC PowerPath for Solaris Version Release Notes

11 Environment and System Requirements documents for prescribed installation information when using AX100-Series storage systems. The following table shows the minimum revision of FLARE supported by PowerPath for Solaris. CLARiiON Storage System AX100 AX100SC CX200 CX300 CX400 CX500 CX600 CX700 Minimum Supported FLARE Version IBM ESS Storage Systems The following table shows the requirements and specifications for a PowerPath host connected to an IBM ESS system: model numbers and firmware supported, maximum number of paths per logical device, and support for booting from an IBM ESS device. Model Array code/firmware required Paths per device Boot support F10/F Solaris 7, 8, 9, /800T Once a host and IBM ESS system are properly configured, you can install or upgrade PowerPath. See the PowerPath for Solaris Installation and Administration Guide for installation details. Hitachi Lightning Storage Systems The following table shows the requirements and specifications for a PowerPath host connected to a Hitachi Lightning system: model numbers and firmware supported, maximum number of paths per EMC PowerPath for Solaris Version Release Notes 11

12 Environment and System Requirements logical device, and support for booting from a Hitachi Lightning device. Model Qualified Array code/firmware Paths per device Boot support 9970V/9980V (or higher) 32 Solaris 7, 8, 9, / (or higher) Once a host and Hitachi Lightning system are properly configured, you can install or upgrade PowerPath. See the PowerPath for Solaris Installation and Administration Guide for installation details. Hitachi TagmaStore The following table shows the requirements and specifications for a PowerPath host connected to a Hitachi TagmaStore system: model numbers and firmware supported, maximum number of paths per logical device, and support for booting from a Hitachi TagmaStore device. Model Qualified Array code/firmware Paths per device Boot support USP / Solaris 8, 9, 10 Hewlett-Packard StorageWorks Arrays The following table shows the requirements and specifications for a PowerPath host connected to an HP StorageWorks system: model numbers and firmware supported, maximum number of paths per 12 EMC PowerPath for Solaris Version Release Notes

13 Environment and System Requirements logical device, and support for booting from an HP StorageWorks device. Model Minimum array code or firmware required Paths per device Boot support HP StorageWorks Disk Array xp 128/1024 HP StorageWorks Disk Array xp 48/ Solaris 8, 9, HP StorageWorks Enterprise Virtual Array (EVA) 3000/5000 VCS3.0, PowerPath does not support VCS4.001 or later 32 Not supported. HP StorageWorks Enterprise Modular HP StorageWorks MA8000/EMA12000 ACS HP StorageWorks HPXP Solaris 8, 9, 10 Once a host and HP StorageWorks system are properly configured, you can install or upgrade PowerPath. See the PowerPath for Solaris Installation and Administration Guide for installation details. Connectivity Requirements Refer to the EMC Support Matrix for information about the requirements for fibre channel and switched fabric configurations and components that can be used with PowerPath. Note: Install host bus adapters (HBAs), their supporting firmware versions, and other network components using the manufacturer s directions and the settings specified in the EMC Support Matrix. Using improper settings can cause erratic failover behavior or extended response time for system I/O. EMC PowerPath for Solaris Version Release Notes 13

14 Known Problems and Limitations Known Problems and Limitations This section describes the known problems and limitations in PowerPath for Solaris. Table 7 Known Problems in PowerPath Version 4.5.0: Solaris Description Workaround Found in Version Resolved in Version powermt core dumps on issuing powermt config or powermt display if the host is connected to 16 or more arrays. Log in to the Powerlink website and download the powermt.solaris b170.tar file and follow the steps mentioned in powermt.solaris b170.readme SYMCLI functionality degrades after uninstalling PowerPath VxVM 4.1 pseudo device mappings (emcpower mappings) may become inconsistent with PowerPath pseudo device mappings. Circumstances that may cause inconsistencies include: VxVM 4.1 is uninstalled and reinstalled after a LUN configuration change. VxVM maps pseudo devices based on device information saved before the uninstall, and these mappings may differ from the current PowerPath mappings and configuration. A pseudo device instance is renamed using emcpadm, which causes VxVM 4.1 to lose the pseudo device mapping. 1. Remove PowerPath. Refer to PowerPath 4.5 for Solaris Installation and Administration Guide. 2. Confirm the no reboot required message appears. 3. Enter: symcfg discover To fix inconsistent device mappings: 1. Enter: cp /etc/vx/disk.info /etc/vx/disk.info.old 2. Enter: echo > /etc/vx/disk.info 3. Enter: vxconfigd -k EMC PowerPath for Solaris Version Release Notes

15 Known Problems and Limitations Table 7 Known Problems in PowerPath Version 4.5.0: Solaris (continued) Description Workaround Found in Version Resolved in Version In a Sun Cluster 3.1 environment with VxVM 4.1, removing PowerPath with the pkgrm command may fail with the following message: EMCpower Removal: Error: PowerPath pseudo(s) still in-use, busy or mounted. Please stop all I/Os and make sure all volumes are not mounted then retry removing the package pkgrm: ERROR: preremove script did not complete successfully Removal of <EMCpower> failed When you upgrade to PowerPath 4.5 from an older version of PowerPath, third-party arrays that are not supported on the older version of PowerPath will come up as unmanaged in PowerPath In a PowerPath environment with a Leadville driver, MPXIO enabled and managing third-party devices, and the Naviagent running, a system crash occurs when you remove PowerPath from the host. Refer to Uninstalling PowerPath in an Environment With Sun Cluster 3.1 and VxVM 4.1 on page 30 for the workaround instructions. Manually manage the unmanaged array classes after you upgrade. Enter: powermt manage class=<class> Refer to the PowerPath Product Guide for more information on the powermt manage command. Stop Naviagent before you uninstall PowerPath A path to a Hitachi storage system is managed by both MPxIO and PowerPath. If your host is connected to a Hitachi storage system, and the parameter mpxio-disable is set to no (mpxio-disable=no), PowerPath will try to manage the path that is already managed by MPxIO. You can verify the status of the Hitachi storage system class by running the command powermt display options. If the status is managed, then manually unmanage the path, as described in the Workaround column. To unmanage the path: 1. Enter: powermt remove dev=all 2. Enter: powermt unmanage class=hitachi 3. Enter: powermt config EMC PowerPath for Solaris Version Release Notes 15

16 Known Problems and Limitations Table 7 Known Problems in PowerPath Version 4.5.0: Solaris (continued) Description Workaround Found in Version Resolved in Version When performing a Solaris Live Upgrade from Solaris 9 to Solaris 10, you need to manually mount the /usr and /var directories. (When you perform a Solaris Live Upgrade from Solaris 8 to 9, this step is not necessary.) Manually mount the /usr and /var directories. Refer to the PowerPath 4.5 for Solaris Installation and Administration Guide for more information on the Live Upgrade procedure EMC PowerPath for Solaris Version Release Notes

17 Known Problems and Limitations Table 7 Known Problems in PowerPath Version 4.5.0: Solaris (continued) Description Workaround Found in Version Resolved in Version With PowerPath or later and VxVM 4.1, the command vxdisk list may display multiple entries for the same device. This may occur following a reboot where PowerPath has just been installed or new devices have been mapped or zoned to a host. The issue occurs because PowerPath pseudo device links are unavailable during boot, and VERITAS VxVM 4.1 depends on these links before they can be created. This usually occurs when PowerPath is uninstalled and reinstalled without clearing the knowledge VxVM 4.1 has of these devices. It can also happen if a new LUN is mapped or zoned to a host and VxVM had prior knowledge of this device With SAN in a CLARiiON basic failover environment, PowerPath does not trespass LUNs when a Fibre Channel cable is pulled from the SP port. When upgrading or reinstalling PowerPath, reboot after the initial package remove, if PowerPath requested the reboot. When duplicate entries are seen, a second reboot will clear the duplicates. The PowerPath pseudo device links will be available during the second reboot. When mapping/zoning new LUNS to the host, to avoid duplicate entries: 1. Run vxddladm stop. eventsource. 2. Map/zone the new LUNS to the host. 3. Dynamically recreate the LUN device (either using cfgadm routines or HBA-specific routines to dynamically create the device nodes). 4. Run powermt config to discover and create the pseudo device links. 5. Run vxddladm start eventsource. When a host is rebooted with a path down, follow this procedure to avoid duplicate entries: 1. Run vxddladm stop eventsource 2. Reconnect the paths. 3. Run powermt config. 4. Run vxddlam start. eventsource. If vxddladm commands were not run, then reboot the system to remove the duplicate entries. Remove SAN and install SAN EMC PowerPath for Solaris Version Release Notes 17

18 Known Problems and Limitations Table 7 Known Problems in PowerPath Version 4.5.0: Solaris (continued) Description Workaround Found in Version Resolved in Version R1/R2 boot support in a Symmetrix 5x71 environment does not work when the Symmetrix SPC2 flag is set to ON In a CLARiiON storage system environment, upgrading to PowerPath 4.5 when pseudo devices are in use causes a failure. File system corruption occurs during the host reboot When you run the syminq command, sometimes the wrong director may be returned from Symmetrix devices. For example, a device returns FA 13aA when you run syminq, but PowerPath returns FA 13dB. This can occur when the PowerPath cache is not updated after a recent device reconfiguration on the Symmetrix system PowerPath 4.5 with Solaris 10 is incompatible with volume managers such as VxVM 4.1 that encapsulate the root device, due to a known problem in VERITAS Volume Manager VERITAS Volume Manager 4.1 does not support PowerPath pseudo device naming with third-party arrays. Ensure that the SPC2 flag is set to OFF if your configuration includes R1/R2 boot support and Symmetrix 5x71. By default, this setting is ON. Remove the device from PowerPath and then add it back. Enter: 1.powermt remove dev=<device> 2.powercf q 3.powermt save 4. powermt config Change the VxVM third-party driver mode (tpdmode) to native by entering: vxdmpadm setattr enclosure <enclosure> tpdmode=native This change also applies to any EMC devices in a mixed-array environment EMC PowerPath for Solaris Version Release Notes

19 Known Problems and Limitations Table 7 Known Problems in PowerPath Version 4.5.0: Solaris (continued) Description Workaround Found in Version Resolved in Version In a Solaris environment with PowerPath and a Leadville driver, running SYMCLI commands generates the following errors in /var/adm/messages: Oct 12 12:03:53 db026ops qlc: [ID kern.info] NOTICE: Qlogic qlc(1): Link ONLINE Oct 12 12:03:53 db026ops scsi: [ID kern.info] /pci@8,600000/sunw,qlc@1/fp@0,0 (fcp1): Oct 12 12:03:53 db026ops Lun=0 for target= disappeared Oct 12 12:03:53 db026ops scsi: [ID kern.info] /pci@8,600000/sunw,qlc@1/fp@0,0 (fcp1): Oct 12 12:03:53 db026ops Lun=0 for target= disappeared Oct 12 12:03:58 db026ops qlc: [ID kern.info] NOTICE: Qlogic qlc(2): Loop OFFLINE Install the appropriate SUN T-patch, or install SAN Refer to the EMC Knowledgebase solution emc for more information Sun Volume Manager metadatabases created on PowerPath pseudo devices may not persist after upgrading to PowerPath 4.4. Move pseudo devices to native devices before upgrading After a fresh installation of PowerPath 4.4 on a Solaris 10 host with a valid license connected to a Symmetrix storage system, the load balancing policy is set to "bf" (basic failover) after the host reboots. The policy should be set to "so" (Symmetrix optimized) Running the powermt remove dev=all and powermt config commands on a host that has mounted the SnapView LUN makes the snapshot inactive, causing data corruption. Run the following commands before you reboot: powermt set policy=so powermt save , Rebooting a PowerPath host that is a node in a Sun 3.1 cluster and is also connected to EVA devices generates volume assign/restore messages and path dead/alive messages. These messages are also seen during node failover. Ignore the messages EMC PowerPath for Solaris Version Release Notes 19

20 Known Problems and Limitations Table 7 Known Problems in PowerPath Version 4.5.0: Solaris (continued) Description Workaround Found in Version Resolved in Version Very infrequently, an admsnap operation (start, stop, etc.) reports the error 0xE10080A3. This error indicates that the specified admsnap operation may not have completed on all of the devices specified on the command line due to an internal operation failing to complete properly to the array. For applications or scripts that rely on the exit status from admsnap, a non-zero exit status is returned to the application or script With third-party arrays in a cluster, reconfiguration reboot does not recover paths that are down at boot In an R1/R2 boot situation, after failover/failback, the following console error message appears after booting from the R2 host: Error occurred loading saved driver state from file /etc/powermt.custom. Loading continues Query the CLARiiON storage array using Navisphere, and determine whether the admsnap command completed the operation for all devices specified on the command line. If it did, no action is required. 2. If the admsnap command failed to complete the operation for all of the devices specified on the command line: For start operations that failed to complete, stop the session on the devices and retry the admsnap command. For activate operations that failed to complete, deactivate the session on the devices and retry the admsnap command. For stop operations that failed to complete, stop the session. No further action is required. For deactivate operations that failed to complete, deactivate the session. No further action is required. 3. If this problem persists, use Navisphere instead of Admsnap to perform the operation. Use either the boot or reboot command. Do not use the boot -r or reboot -- -r command. Ignore this message. The custom settings are loaded EMC PowerPath for Solaris Version Release Notes

21 Known Problems and Limitations Table 7 Known Problems in PowerPath Version 4.5.0: Solaris (continued) Description Workaround Found in Version Resolved in Version powermt restore restores all paths to third-party arrays when periodic autorestore is set to off. This includes, among others, HPXP and Hitachi Lightning devices Using the powermt unmanage class=hitachi command to unmanage third-party arrays when the host is booted from a pseudo device prevents the system from coming up after you reboot. You see the following message when you unmanage a boot device: WARNING: One or more boot devices have been unmanaged. Update the system configuration settings as appropriate. Cannot remove device that is in use: <emcpowerx> LUNs are trespassed when the HBAs are removed one by one using the powermt remove hba=# command PowerPath installation or removal fails if pkgadd or pkgrm is interrupted Executing emcpreg -f -edit without specifying the PowerPath registration filename (the default is emcp_registration) could cause deletion of the registration file s parent directory. (The default parent directory is /etc.) For example, if your PowerPath registration file is in the /test directory and you execute the command emcpreg -f /test -edit, you see the following prompt: EMCP registration file is corrupt. Delete it? If you answer y (yes) to the prompt, /test is deleted. Before you reboot the host, update the system configuration in the /etc/system and /etc/vfstab files to use native devices. Refer to the PowerPath 4.5 for Solaris Installation and Administration Guide for more information. Reboot the host and then rerun pkgadd or pkgrm. If your PowerPath registration file is the default file (/etc/emcp_registra tion), do not use the -f option with emcpreg. Otherwise, be sure to specify the full pathname. Enter: emcpreg -f /directory/filename -edit If you neglect to specify the full pathname, answer n (no) to the prompt: EMCP registration file is corrupt. Delete it? EMC PowerPath for Solaris Version Release Notes 21

22 Known Problems and Limitations Limitations PowerPath for Solaris has the following limitations: In an R1/R2 boot support environment: PowerPath 4.5 does not support Sun HBAs X6767A and X6768A. R1/R2 boot support hosts must be connected directly to the Symmetrix system; they cannot be connected through the fabric. VERITAS Volume Manager does not support PowerPath pseudo device naming with third-party arrays. You can change the VxVM third-party driver mode (tpdmode) to native by entering: vxdmpadm setattr enclosure <enclosure> tpdmode=native This change also applies to any EMC devices in a mixed array environment. PowerPath cannot co-manage devices with third-party path management software such as Hitachi Dynamic Link Manager (HDLM), IBM Subsystem Device Driver (SDD), HP StorageWorks Secure Path, or HP StorageWorks Auto Path XP Virtual Array. During installation of PowerPath 4.5.0, the installation script tests for the presence of third-party path management software on the system. If such software is installed on the system, the PowerPath installation script disables support for the corresponding array type in PowerPath: If this software is present HDLM SDD HP StorageWorks Secure Path HP StorageWorks Auto Path XP Virtual Array Support for this array type is disabled in PowerPath Hitachi Lightning, Hitachi TagmaStore IBM ESS HP StorageWorks EVA, EMA, MA HP StorageWorks xp Since PowerPath coexistence is not supported by third-party array path management products, when you enable PowerPath (powermt manage class=<class>) for a class that is being managed by a third-party product, multipathing behavior is undefined. 22 EMC PowerPath for Solaris Version Release Notes

23 Known Problems and Limitations Since PowerPath is not supported in third-party path management environments when the corresponding storage system class type is in the managed state, multipathing behavior for any attached arrays in the corresponding class is undefined if you subsequently execute a powermt manage class= command: If this software is present HDLM SDD HP StorageWorks Secure Path HP StorageWorks Auto Path XP Virtual Array Multipathing behavior is undefined if you execute this command powermt manage class=hitachi powermt manage class=ess powermt manage class=hphsx powermt manage class=hpxp Since PowerPath and the third-party software cannot co-manage devices, do not initiate co-management by executing this command on third-party array class machines. As long as this command is not executed, support for the relevant third-party arrays will remain disabled across reboots. Similarly, before you install third-party path management software on a system on which PowerPath is already installed, you should disable any support by PowerPath for the relevant third-party array devices using a powermt unmanage class= command: Before you install this software HDLM SDD HP StorageWorks Secure Path HP StorageWorks Auto Path XP Virtual Array Execute this command powermt unmanage class=hitachi powermt unmanage class=ess powermt unmanage class=hphsx powermt unmanage class=hpxp PowerPath does not support load balancing and failover for applications that use the SCSI-2 Reserve/Release or Solaris MHIOCTKOWN IOCTL command set in an EMC Invista, IBM ESS, Hitachi Lightning, Hitachi TagmaStore, or HP StorageWorks environment. EMC PowerPath for Solaris Version Release Notes 23

24 Known Problems and Limitations If you deploy any such applications, you must set the load balancing and failover policy to nr (No redirect). Refer to the powermt set policy command description in the PowerPath Product Guide for more information on setting load balancing and failover policies. The following is an issue with Sun s native driver. When using Sun's qlc driver, you might see the following message on the system console at boot: emcp: info: Not all paths to <array_type> <array_number> vol <volume_number> are dead. Any application configured to use the devices too soon (vfstab mounts for instance) will fail to open its device. Note: The paths will be autorestored in time, or you can run powermt restore to restore them. To avoid this situation, when using Sun's native driver: 1. Add the following line to the /etc/system file: set fcp:ssfcp_enable_auto_configuration=1 2. Reboot the host. Using PowerPath pseudo names under VxVM 4.0 is subject to several limitations. Refer to VxVM 4.0 and PowerPath Pseudo Names on page 27 for details. PowerPath cannot failover path-specific requests, such as dev_info. 24 EMC PowerPath for Solaris Version Release Notes

25 Technical Notes Technical Notes This section contains additional information on PowerPath not covered in the core documents. This section includes the following subsections: Upgrading From PowerPath 3.0.x on page 25 Upgrading From PowerPath 4.0.x on Symmetrix Systems on page 25 VxVM 4.0 and PowerPath Pseudo Names on page 27 Pseudo Names With VxVM 4.1 and PowerPath on page 28 Uninstalling PowerPath in an Environment With Sun Cluster 3.1 and VxVM 4.1 on page 30 HP StorageWorks Controller and Port Names on page 30 Removing HP StorageWorks Secure Path on page 31 Upgrading From PowerPath 3.0.x When upgrading from PowerPath 3.0.x to PowerPath 4.x, run the chmod +r /etc/powermt.custom.saved command to enable all read permissions on the saved version of the powermt.custom file after uninstalling 3.0.x and before installing 4.x. If you do not enable read permissions on the powermt.custom.saved file, PowerPath may not be able to perform an upgrade installation, depending on the version and patch level of Solaris running on the host. Upgrading From PowerPath 4.0.x on Symmetrix Systems Note: In the vast majority of cases, upgrading from PowerPath 4.0.x to PowerPath on a Solaris host in a Symmetrix environment succeeds without incident. In the rare circumstance that a Symmetrix system matches the configuration described below, take special care when upgrading, following the instructions in this section. If your Solaris host is running any version of PowerPath 4.0.x and is attached to a Symmetrix system with a serial number with 8 or 9 as the fifth number from the right (for example, HK ), contact Customer Support before upgrading to PowerPath Customer EMC PowerPath for Solaris Version Release Notes 25

26 Technical Notes Support will provide you with a tool and procedure to follow to safely upgrade your server. If you remove PowerPath 4.0.x and install PowerPath without contacting Customer Support, the upgrade to PowerPath will stop with the following message: emcp_registration version 402 detected. emcpupgrade: error - configuration files corrupted. emcpupgrade: Detected inconsistency with saved Symmetrix serial numbers * EMCpower Installation: * * Can not upgrade at this time. * There is a problem with the saved powerpath config files. * Please contact customer service to complete UPGRADE * EMCpower Installation: * * Configuration files conversion unsuccessful!!! * The PowerPath 4.5 Package was successfully installed, but there is a known * issue with your configuration files. * * In order to upgrade your configuration, please contact EMC Customer Service * for assistance. Do not reboot. Do not restart your applications. * Consult the 4.5 Release Notes All trademarks used herein are the property of their respective owners. Installation of <EMCpower> was successful. In addition to the console output, the following will appear in the system log: date and time system Can[16107]: [ID daemon.notice] not upgrade at this time. There is a problem with the saved powerpath config files. date and time system Contact[16434]: [ID daemon.notice] Customer Service. Do not reboot. Do not restart your applications. Consult the 4.5 Release Notes. If this happens, we strongly recommend that you: 1. Remove PowerPath Reinstall the version of 4.0.x that you were running previously. 3. Reboot the host. 4. Contact Customer Support for further instructions; reference EMC Knowledge Base article emc EMC PowerPath for Solaris Version Release Notes

27 Technical Notes VxVM 4.0 and PowerPath Pseudo Names You can use the powervxvm install utility to make PowerPath pseudo device names available under VxVM 4.0. Be aware that both native device names and PowerPath pseudo device names will be visible to VxVM 4.0. Both names will be reported in vxdisk list output, which typically looks like this: c3t2d1s2 auto:none - - online invalid emcpower0c simple - - online invalid Both devices represent the same LUN. To avoid confusion, you can use the VxVM vxdiskadm utility to exclude the native devices (in the example above, c3t2d1s2) from the VxVM view. Refer to VxVM vxdiskadm documentation for details. Upgrading to VxVM 4.0 After upgrading to VxVM 4.0 from a VxVM 3.5 (or earlier) installation that was configured to use PowerPath pseudo device names, use the following procedure to reintroduce PowerPath pseudo device names in VxVM Place PowerPath pseudo device names under VxVM 4.0 using powervxvm. You can do this for all emcpower devices, or for individually selected devices: For all devices, run the following command: powervxvm define For individual devices: a. Run the following command: powervxvm install Note: Important: Use powervxvm install and not powervxvm init. powervxvm init corrupts the rootdg for some versions of VxVM. b. Select Option 3 Install one device at a time. c. For each device to be used under VxVM 4.0, select Option 2 to define. EMC PowerPath for Solaris Version Release Notes 27

28 Technical Notes! CAUTION Do not initialize the emcpower disks if they currently contain VxVM volumes. 2. Re-import previously existing disk groups/volumes. The simplest way to do this it to reboot using the following command: shutdown -i6 However, if you cannot reboot, use the following procedure: a. Request that VxVM re-import any disk groups by restarting vxconfigd; run the following command: vxdctl enable b. For each disk group that was rediscovered, request that all volumes on that disk group be restarted; run the following command: vxvol g diskgroup startall Limitations PowerPath pseudo devices are identified as simple disks by VxVM. Thus: VERITAS CDS (common-disk-schema) is not supported with PowerPath pseudo device names. The cds attribute must be disabled when creating the disk group. Run a command like the following: vxdg init symmdg disk=emcpower0c cds=off The default for VxVM 4.0 disk groups is CDS=ON. Therefore, if you have existing VxVM 4.0 disk groups/volumes (without PowerPath) you cannot use powervxvm scripts to migrate to PowerPath pseudo devices. Pseudo Names With VxVM 4.1 and PowerPath When you install VxVM 4.1 in a PowerPath environment, VxVM converts any EMC Symmetrix and CLARiiON devices with native names to pseudo names (emcpower names). EMC recommends using the default naming convention (pseudo names) for EMC storage devices. However, it is possible to configure native names (c#t#d# names) for EMC devices, as described in this section. 28 EMC PowerPath for Solaris Version Release Notes

29 Technical Notes Note: The powervxvm utility does not support pseudo device names for third-party devices in the VERITAS device list. The following error message appears when you try to bring third-party device s into the VxVM device list: VxVM vxdisk ERROR V Device emcpower3s2: init failed: device path not valid. Pseudo device names for third-party arrays are not supported with VxVM 4.1. You can only use pseudo device names for Symmetrix and CLARiiON devices. Changing EMC Devices to Native Device Names Note: Use the procedure in this section only if the default disk-naming scheme is set to operating system based naming, and the TPD-controlled enclosure does not contain fabric disks. To change EMC storage devices from the default pseudo names to native names: 1. View the pseudo device names that appear after installing VxVM 4.1. Enter: # vxdisk list Output: DEVICE TYPE DISK GROUP STATUS emcpower10s2 auto:sliced disk1 mydg online emcpower11s2 auto:sliced disk2 mydg online emcpower12s2 auto:sliced disk3 mydg online emcpower13s2 auto:sliced disk4 mydg online emcpower14s2 auto:sliced disk5 mydg online emcpower15s2 auto:sliced disk6 mydg online emcpower16s2 auto:sliced disk7 mydg online emcpower17s2 auto:sliced disk8 mydg online emcpower18s2 auto:sliced disk9 mydg online emcpower19s2 auto:sliced disk10 mydg online 2. Change the pseudo names to native names. Enter: # vxdmpadm setattr enclosure <enclosure> tpdmode=native Where <enclosure> is the enclosure name of the EMC device. Example: # vxdmpadm settattr enclosure EMC0 tpdmode=native 3. List the device names and note the different naming convention in the Device column. Enter: EMC PowerPath for Solaris Version Release Notes 29

30 Technical Notes # vxdisk list Output: DEVICE TYPE DISK GROUP STATUS c6t0d10s2 auto:sliced disk1 mydg online c6t0d11s2 auto:sliced disk2 mydg online c6t0d12s2 auto:sliced disk3 mydg online c6t0d13s2 auto:sliced disk4 mydg online c6t0d14s2 auto:sliced disk5 mydg online c6t0d15s2 auto:sliced disk6 mydg online c6t0d16s2 auto:sliced disk7 mydg online c6t0d17s2 auto:sliced disk8 mydg online c6t0d18s2 auto:sliced disk9 mydg online c6t0d19s2 auto:sliced disk10 mydg online If tpdmode is set to native, the subpath with the smallest device number is displayed. Uninstalling PowerPath in an Environment With Sun Cluster 3.1 and VxVM 4.1 If you attempt to remove PowerPath in a Sun Cluster 3.1 with VxVM 4.1 environment, and pkgrm fails, enter the following commands. Then retry pkgrm. # cd /dev/rdsk # for path in `ls emcpower*c` do /usr/sbin/vxdmpadm -f disable path=${path} done # Uninstall PowerPath following the directions in the PowerPath 4.5 for Solaris Installation and Administration Guide. HP StorageWorks Controller and Port Names PowerPath names for HP StorageWorks EVA and HSG80 controllers and ports differ from the names in the array GUIs. This section describes the differences. HP StorageWorks EVA Names PowerPath identifies controllers A and B exactly as Command View EVA does. PowerPath port numbers are one lower than Command View EVA port numbers. 30 EMC PowerPath for Solaris Version Release Notes

31 Technical Notes Names are mapped as follows: Command View EVA name PowerPath name A-1 A-0 A-2 A-1 B-1 B-0 B-2 B-1 HP StorageWorks HSG80 PowerPath names the bottom controller A and the top controller B. PowerPath port numbers are one lower than HSG Element Manager port numbers. Names are mapped as follows: HSG Element Manager name PowerPath name Bottom-1 A-0 Bottom-2 A-1 Top-1 B-0 Top-2 B-1 Removing HP StorageWorks Secure Path After you remove HP StorageWorks Secure Path from a system that has JNI/AMCC FCA-1063 HBAs configured, the powermt display command shows only one HBA, or no HBAs. 1. Remove Secure Path bindings from the HBA configuration (.conf) file and sd.conf. Establish PowerPath static bindings as follows: LPFC: Add to lpfc.conf: EMC PowerPath for Solaris Version Release Notes 31

32 Technical Notes fcp-bind-wwpn="50001fe10010f621:lpfc0t0", "50001fe10010f622:lpfc0t1", "50001fe10010f623:lpfc1t2", "50001fe10010f624:lpfc1t3", "50001fe15002f00d:lpfc0t4", "50001fe15002f00c:lpfc0t5", "50001fe15002f009:lpfc1t6", "50001fe15002f008:lpfc1t7"; Qlogic: Add to qlaxxxx.conf: hba0-scsi-target-id-4-fibre-channel-port-name="50001fe15000b028"; hba0-scsi-target-id-5-fibre-channel-port-name="50001fe15000b029"; hba0-scsi-target-id-6-fibre-channel-port-name="50001fe15000b02c"; hba0-scsi-target-id-7-fibre-channel-port-name="50001fe15000b02d"; hba1-scsi-target-id-4-fibre-channel-port-name="50001fe15000b028"; hba1-scsi-target-id-5-fibre-channel-port-name="50001fe15000b029"; hba1-scsi-target-id-6-fibre-channel-port-name="50001fe15000b02c"; hba1-scsi-target-id-7-fibre-channel-port-name="50001fe15000b02d"; JNIs: fcaw.conf and fca-pci.conf #EVA Bindings target4_hba="fcaw0"; target4_wwpn="50001fe15000b028"; target5_hba="fcaw0"; target5_wwpn="50001fe15000b02d"; target6_hba="fcaw1"; target6_wwpn="50001fe15000b029"; target7_hba="fcaw1"; target7_wwpn="50001fe15000b02c"; 2. Add the following to sd.conf: # EVA5000 name="sd" class="scsi" target=4 lun=0; name="sd" class="scsi" target=4 lun=1; name="sd" class="scsi" target=4 lun=2; name="sd" class="scsi" target=4 lun=3; name="sd" class="scsi" target=4 lun=4; name="sd" class="scsi" target=4 lun=5; name="sd" class="scsi" target=4 lun=6; name="sd" class="scsi" target=4 lun=7; 3. List the above entries for each target you have defined in the HBA configuration (.conf) file. 4. Finally, reboot the host: reboot -- -r 32 EMC PowerPath for Solaris Version Release Notes

33 Documentation Documentation PowerPath Documentation This section provides a list of the documentation that supports PowerPath for Solaris. The following table lists the PowerPath documentation set; all manuals are available from EMC Corporation. Electronic versions of all PowerPath manuals are available on the Powerlink website: These manuals are updated periodically, and the updated manuals are posted on the Powerlink website. Name PowerPath 4.5 for Solaris Installation and Administration Guide EMC PowerPath 4.5 for Solaris Release Notes PowerPath 4.5 Product Guide EMC PowerPath 4.5 Quick Reference Related Documentation If your environment includes Symmetrix storage systems, refer also to the EMC host connectivity guides, which are available on the Powerlink website. If your environment includes CLARiiON storage systems, refer also to the following manuals: EMC host connectivity guides EMC Installation Roadmap for CX-Series and FC-Series Storage Systems CLARiiON AX100-Series installation, planning, and troubleshooting documents, located on the AX100 support website. For information on accessing the site, refer to the support documentation that shipped with your storage system. Refer only to these documents for prescribed installation information when using AX100-Series storage systems. EMC Navisphere Manager Version 6.X Administrator s Guide If your environment includes other vendors storage systems, refer to the appropriate documentation from your vendor. EMC PowerPath for Solaris Version Release Notes 33

Release Notes. EMC PowerPath for Linux. Version 4.3. P/N Rev A09. June 7, 2005

Release Notes. EMC PowerPath for Linux. Version 4.3. P/N Rev A09. June 7, 2005 R E L E A S E N O T E S EMC PowerPath for Linux Version 4.3 Release Notes P/N 300-001-969 Rev A09 June 7, 2005 Revision History: June 7, 2005, May 13, 2005, April 11, 2005, February 22, 2005, January 14,

More information

Release Notes P/N Rev A02

Release Notes P/N Rev A02 EMC PowerPath for Windows Version 4.6 and Point Releases Release Notes P/N 300-003-931 Rev A02 November 27, 2006 These release notes contain information about features, system requirements, known problems,

More information

Release Notes P/N Rev A05

Release Notes P/N Rev A05 EMC PowerPath for Linux Version 4.5 and Point Releases Release Notes P/N 300-002-840 Rev A05 July 3, 2006 These release notes contain information about features, system requirements, and limitations in

More information

Release Notes P/N REV A03 January 3, 2006

Release Notes P/N REV A03 January 3, 2006 Sun StorEdge Traffic Manager for CLARiiON Release Notes P/N 300-002-978 REV A03 January 3, 2006 These release notes contain supplemental information about Sun StorEdge Traffic Manager for CLARiiON storage

More information

Installing PowerPath. Invisible Body Tag

Installing PowerPath. Invisible Body Tag Invisible Body Tag 1 Installing PowerPath This chapter describes procedures to install and upgrade EMC PowerPath software on a Windows host. This chapter includes the following sections: Before you install...

More information

PowerPath PRODUCT GUIDE. Version 4.6 P/N REV A03

PowerPath PRODUCT GUIDE. Version 4.6 P/N REV A03 PowerPath Version 4.6 PRODUCT GUIDE P/N 300-003-927 REV A03 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508 -435-1000 www.emc.com Copyright 1997-2006 EMC Corporation. All rights

More information

HP StorageWorks MPxIO for Sun Solaris application notes

HP StorageWorks MPxIO for Sun Solaris application notes HP StorageWorks MPxIO for Sun Solaris application notes Part number: AA-RW7CD-TE Third edition: August 2006 Legal and notice information Copyright 2005-2006 Hewlett-Packard Development Company, L.P. Hewlett-Packard

More information

EMC PowerPath for AIX Version 5.1

EMC PowerPath for AIX Version 5.1 EMC PowerPath for AIX Version 5.1 Installation and Administration Guide P/N 300-005-461 REV A03 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1997-2008

More information

HP StorageWorks MPxIO for Sun Solaris application notes

HP StorageWorks MPxIO for Sun Solaris application notes HP StorageWorks MPxIO for Sun Solaris application notes Part number: AA-RW7CE-TE Third edition: December 2006 Legal and notice information Copyright 2005-2006 Hewlett-Packard Development Company, L.P.

More information

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05

EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N REV A05 EMC CLARiiON Server Support Products for Windows INSTALLATION GUIDE P/N 300-002-038 REV A05 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2004-2006

More information

Technical Note P/N REV A01 November 24, 2008

Technical Note P/N REV A01 November 24, 2008 AIX Native MPIO for CLARiiON Technical Note P/N 300-008-486 REV A01 November 24, 2008 This technical note contains supplemental information about AIX Native MPIO for CLARiiON storage systems. Technical

More information

Terminology. This document uses the following terms:

Terminology. This document uses the following terms: CX4 Architecture for NS Series Connecting a CX4-48 Storage System in a Fibre Channel Direct or Switch Configuration with a Microsoft Windows Server with Native Multipath Failover December 6, 28 If you

More information

EMC Symmetrix with VERITAS Dynamic Multi-pathing (DMP)

EMC Symmetrix with VERITAS Dynamic Multi-pathing (DMP) EMC Symmetrix with VERITAS Dynamic Multi-pathing (DMP) Best Practices Planning Abstract This white paper provides best practices for configuring VERITAS Dynamic Multi-pathing (DMP) in an EMC Symmetrix

More information

EMC PowerPath Family Version 5.2 and 5.3

EMC PowerPath Family Version 5.2 and 5.3 EMC PowerPath Family Version 5.2 and 5.3 CLI and System Messages Reference Guide P/N 300-008-343 REV A10 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

Storage Compatibility Guide for ESX Server 3.0

Storage Compatibility Guide for ESX Server 3.0 Storage Compatibility Guide for ESX Server 3.0 VMware ESX Server software has been tested and deployed in a variety of storage area network (SAN) environments. This guide describes the combinations of

More information

EMC PowerPath for AIX Version 5.3

EMC PowerPath for AIX Version 5.3 EMC PowerPath for AIX Version 5.3 Installation and Administration Guide P/N 300-008-341 REV A08 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 1997-2011

More information

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide

HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide HP StorageWorks 4000/6000/8000 Enterprise Virtual Array connectivity for Sun Solaris installation and reference guide Part number: 5697-5263 First edition: May 2005 Legal and notice information Copyright

More information

WHITE PAPER: ENTERPRISE SOLUTIONS. Veritas Storage Foundation for Windows Dynamic Multi-pathing Option. Competitive Comparisons

WHITE PAPER: ENTERPRISE SOLUTIONS. Veritas Storage Foundation for Windows Dynamic Multi-pathing Option. Competitive Comparisons WHITE PAPER: ENTERPRISE SOLUTIONS Veritas Storage Foundation for Windows Competitive Comparisons White Paper: Enterprise Solutions Veritas Storage Foundation for Windows Contents Introduction........................................................................4

More information

Veritas Dynamic Multipathing Administrator's Guide

Veritas Dynamic Multipathing Administrator's Guide Veritas Dynamic Multipathing Administrator's Guide Solaris 5.1 Rolling Patch 1 DMP Veritas Dynamic Multipathing Administrator's Guide The software described in this book is furnished under a license agreement

More information

Release Notes P/N REV A05 July 7, 2006

Release Notes P/N REV A05 July 7, 2006 EMC CX-Series SAN Copy for FLARE OE Version 02.19.yyy Release Notes P/N 300-002-755 REV A05 July 7, 2006 These release notes contain supplemental information about the following EMC products: EMC SAN Copy

More information

EMC Fibre Channel with Emulex Host Bus Adapters in the Solaris Environment

EMC Fibre Channel with Emulex Host Bus Adapters in the Solaris Environment EMC Fibre Channel with Emulex Host Bus Adapters in the Solaris Environment P/N 300-001-156 REV A11 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright

More information

HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 3.1A for Sun Solaris release notes

HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 3.1A for Sun Solaris release notes HP StorageWorks 3000/5000 Enterprise Virtual Array connectivity 3.1A for Sun Solaris release notes Part number: 5697-6384 First edition: June 2007 Legal and notice information Copyright 2007 Hewlett-Packard

More information

EMC SAN Copy Command Line Interfaces

EMC SAN Copy Command Line Interfaces EMC SAN Copy Command Line Interfaces REFERENCE P/N 069001189 REV A13 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2008 EMC Corporation. All

More information

EMC CLARiiON Asymmetric Active/Active Feature (ALUA)

EMC CLARiiON Asymmetric Active/Active Feature (ALUA) A Detailed Review Abstract This white paper provides an overview of the EMC CLARiiON Asymmetric Active/Active feature. It highlights the configuration, best practices, implementation details of EMC PowerPath,

More information

FlexArray Virtualization

FlexArray Virtualization Updated for 8.3.1 FlexArray Virtualization Implementation Guide for Third-Party Storage NetApp, Inc. 495 East Java Drive Sunnyvale, CA 94089 U.S. Telephone: +1 (408) 822-6000 Fax: +1 (408) 822-4501 Support

More information

HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes

HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes HP StorageWorks Using the QLogic HBA driver for single-path or multipath failover mode on Linux systems application notes Part number: AA-RVGWG-TE Sixth edition: July 2006 Legal and notice information

More information

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment

Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment Symmetrix Fibre Channel with Qlogic Host Bus Adapters in the SCO UnixWare 7 Environment November 2000 Copyright 2000 EMC Corporation. All rights reserved. No part of this publication may be reproduced

More information

VERITAS Dynamic MultiPathing (DMP) Increasing the Availability and Performance of the Data Path

VERITAS Dynamic MultiPathing (DMP) Increasing the Availability and Performance of the Data Path White Paper VERITAS Storage Foundation for Windows VERITAS Dynamic MultiPathing (DMP) Increasing the Availability and Performance of the Data Path 12/6/2004 1 Introduction...3 Dynamic MultiPathing (DMP)...3

More information

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005)

MSA1500csReleaseNotes8_ txt MSA1500cs ReleaseNotes. hp StorageWorks Modular Smart Array 1500 cs Release Notes. Third Edition (February 2005) MSA1500cs ReleaseNotes hp StorageWorks Modular Smart Array 1500 cs Release Notes Third Edition (February 2005) Publication of the third edition of this document coincides with the release of MSA1500 cs

More information

VERITAS Dynamic Multipathing. Increasing the Availability and Performance of the Data Path

VERITAS Dynamic Multipathing. Increasing the Availability and Performance of the Data Path VERITAS Dynamic Multipathing Increasing the Availability and Performance of the Data Path 1 TABLE OF CONTENTS I/O Path Availability and Performance... 3 Dynamic Multipathing... 3 VERITAS Storage Foundation

More information

HP Serviceguard for Linux Certification Matrix

HP Serviceguard for Linux Certification Matrix Technical Support Matrix HP Serviceguard for Linux Certification Matrix Version 04.05, April 10 th, 2015 How to use this document This document describes OS, Server and Storage support with the listed

More information

FlexArray Virtualization Implementation Guide for Third- Party Storage

FlexArray Virtualization Implementation Guide for Third- Party Storage ONTAP 9 FlexArray Virtualization Implementation Guide for Third- Party Storage June 2018 215-11150_F0 doccomments@netapp.com Table of Contents 3 Contents Where to find information for configurations with

More information

Dynamic Multi-Pathing 7.1 Administrator's Guide - Solaris

Dynamic Multi-Pathing 7.1 Administrator's Guide - Solaris Dynamic Multi-Pathing 7.1 Administrator's Guide - Solaris May 2016 Dynamic Multi-Pathing Administrator's Guide Last updated: 2016-05-26 Document version: 7.1 Rev 1 Legal Notice Copyright 2016 Veritas Technologies

More information

HP StorageWorks Continuous Access EVA 2.1 release notes update

HP StorageWorks Continuous Access EVA 2.1 release notes update HP StorageWorks Continuous Access EVA 2.1 release notes update Part number: T3687-96038 Third edition: August 2005 Legal and notice information Copyright 2005 Hewlett-Packard Development Company, L.P.

More information

AX150-Series Upgrading FLARE Operating Environment Software March 28, 2006

AX150-Series Upgrading FLARE Operating Environment Software March 28, 2006 AX150-Series Upgrading FLARE Operating Environment Software March 28, 2006 This document describes how to upgrade your AX150 FLARE Operating Environment (OE) - the storage-system software that includes

More information

Hitachi Vantara Hitachi Dynamic Link Manager Software Interoperability Support Matrix

Hitachi Vantara Hitachi Dynamic Link Manager Software Interoperability Support Matrix 1. Revision Page 1 Hitachi Vantara Hitachi Dynamic Link Manager Software Interoperability Support Matrix Note: This document contains support information for only the 3 most recent versions of Hitachi

More information

HP StorageWorks Enterprise Virtual Array

HP StorageWorks Enterprise Virtual Array Release Notes HP StorageWorks Enterprise Virtual Array Product Version: v3.025 First Edition March, 2005 Part Number: 5697 5237 *5697-5237* This document contains the most recent product information about

More information

Dell EMC Unity Family

Dell EMC Unity Family Dell EMC Unity Family Version 4.2 Configuring Hosts to Access Fibre Channel (FC) or iscsi Storage 302-002-568 REV 03 Copyright 2016-2017 Dell Inc. or its subsidiaries. All rights reserved. Published July

More information

Release Notes P/N REV A04 July 7, 2006

Release Notes P/N REV A04 July 7, 2006 cre EMC CX-Series SnapView For FLARE OE Version 02.19.yyy Release Notes P/N 300-002-753 REV A04 July 7, 2006 These release notes contain supplemental information about the following EMC products: SnapView

More information

HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes

HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes HP StorageWorks Booting Windows Server 2003 for Itanium-based systems from a storage area network application notes Part number: AA RV22F TE Sixth edition: August 2006 Legal and notice information Copyright

More information

Release Notes P/N REV A01 August 11, 2010

Release Notes P/N REV A01 August 11, 2010 EMC Unisphere Analyzer Version 1.0.0 Release Notes P/N 300-011-113 REV A01 August 11, 2010 These release notes contain supplemental information about EMC Unisphere Analyzer, version 1.0.0. Topics include:

More information

EMC Simple Support Matrix

EMC Simple Support Matrix EMC Simple Support Matrix EMC Symmetrix DMX-3 and DMX-4 OCTOBER 2014 P/N 300-013-399 REV 33 2011-2014 EMC Corporation. All Rights Reserved. EMC believes the information in this publication is accurate

More information

Hitachi Vantara Hitachi Dynamic Link Manager Software Interoperability Support Matrix

Hitachi Vantara Hitachi Dynamic Link Manager Software Interoperability Support Matrix 1. Revision Hitachi Vantara Hitachi Dynamic Link Manager Software Interoperability Support Matrix Note: This document contains support information for only the 3 most recent versions of Hitachi Dynamic

More information

Veritas Storage Foundation for HPE-OEM Solutions 6.1 Hardware Compatibility List

Veritas Storage Foundation for HPE-OEM Solutions 6.1 Hardware Compatibility List Veritas Storage Foundation for HPE-OEM Solutions 6.1 Hardware Compatibility List Copyright 2018 Veritas Technologies LLC. All rights reserved. Veritas Technologies, and the Veritas Technologies Logo are

More information

Veritas Dynamic Multi-Pathing Administrator's Guide

Veritas Dynamic Multi-Pathing Administrator's Guide Veritas Dynamic Multi-Pathing Administrator's Guide AIX DMP 5.1 Rolling Patch 1 Patch 0 Veritas Dynamic Multi-Pathing Administrator's Guide The software described in this book is furnished under a license

More information

NetBackup SAN Client and Fibre Transport Troubleshooting Guide. 2 What are the components of the SAN Client feature?

NetBackup SAN Client and Fibre Transport Troubleshooting Guide. 2 What are the components of the SAN Client feature? Symantec TechNote 288437 NetBackup SAN Client and Fibre Transport Troubleshooting Guide 1 Introduction Revision F This document explains how to troubleshoot different failures that may occur while using

More information

EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version

EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version EMC NetWorker Module for SnapImage Release 2.0 Microsoft Windows Version Installation and Administration Guide P/N 300-007-130 REV A01 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000

More information

Storage / SAN Compatibility Guide For ESX Server 3.x

Storage / SAN Compatibility Guide For ESX Server 3.x Storage / SAN Compatibility Guide For ESX Server 3.x Last Updated: January 31, 2007 What s New Changes since the last edition of this guide include:! Added support for the NEC istorage S550. See NEC on

More information

EMC Navisphere Server Software for Solaris ADMINISTRATOR S GUIDE. EMC Enterprise Storage

EMC Navisphere Server Software for Solaris ADMINISTRATOR S GUIDE. EMC Enterprise Storage EMC Enterprise Storage EMC Navisphere Server Software for Solaris ADMINISTRATOR S GUIDE P/N 069001068-01 EMC Corporation 171 South Street, Hopkinton, MA 01748-9103 Corporate Headquarters: (508) 435-1000,

More information

Dynamic Multi-Pathing 7.0 Administrator's Guide - AIX

Dynamic Multi-Pathing 7.0 Administrator's Guide - AIX Dynamic Multi-Pathing 7.0 Administrator's Guide - AIX December 2015 Dynamic Multi-Pathing Administrator's Guide The software described in this book is furnished under a license agreement and may be used

More information

Release Notes P/N REV A01 February 23, 2006

Release Notes P/N REV A01 February 23, 2006 EMC AX-Series Navisphere SP Agent Version 6.20.0.3.12 for FLARE OE 02.20.yyy Release Notes P/N 300-003-516 REV A01 February 23, 2006 These release notes contain supplemental information about EMC Navisphere

More information

Site Search. EMC Power Path commands for system administrators. 1 sur 10 18/07/ :02

Site Search. EMC Power Path commands for system administrators. 1 sur 10 18/07/ :02 elearning Unix & Linux Beginners Unix & Linux Intermediate Unix & Linux Experts Storage Administration ( SAN / NAS ) Site Search EMC Power Path commands for system administrators By unixadminschool com

More information

VERITAS Storage Foundation 4.0 for Windows

VERITAS Storage Foundation 4.0 for Windows DATASHEET VERITAS Storage Foundation 4.0 for Windows Advanced Volume Management Technology for Microsoft Windows Server 2003 In distributed client/server environments, users demand that databases, mission-critical

More information

Veritas Dynamic Multi-Pathing Administrator's Guide

Veritas Dynamic Multi-Pathing Administrator's Guide Veritas Dynamic Multi-Pathing Administrator's Guide Solaris 6.0.1 July 2012 Veritas Dynamic Multi-Pathing Administrator's Guide The software described in this book is furnished under a license agreement

More information

Introduction to the CX700

Introduction to the CX700 Engineering White Paper Introduction to the CX700 Abstract This white paper introduces the full 2 Gb architecture and functionality of the CX700 storage system. It compares the features and capabilities

More information

VERITAS Volume Manager Hardware Application Note

VERITAS Volume Manager Hardware Application Note VERITAS Volume Manager Hardware Application Note Release 3.0.4 READ THIS BEFORE INSTALLING THE SOFTWARE! Solaris April 2000 P/N 100-001593 1998-2000 VERITAS Software Corporation. All rights reserved. TRADEMARKS

More information

EMC ControlCenter 6.0. Support Matrix P/N REV A15. EMC Corporation Corporate Headquarters: Hopkinton, MA

EMC ControlCenter 6.0. Support Matrix P/N REV A15. EMC Corporation Corporate Headquarters: Hopkinton, MA EMC ControlCenter 6.0 Support Matrix P/N 300-004-026 REV A15 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2008 EMC Corporation. All rights reserved.

More information

HP StorageWorks SmartStart EVA Storage 3.2 Release Notes

HP StorageWorks SmartStart EVA Storage 3.2 Release Notes HP StorageWorks SmartStart EVA Storage 3.2 Release Notes Part Number: T5505-96034 Second edition: June 2010 Legal and notice information Copyright 2010 Hewlett-Packard Development Company, L.P. Microsoft

More information

Veritas Dynamic Multi-Pathing Administrator's Guide - AIX

Veritas Dynamic Multi-Pathing Administrator's Guide - AIX Veritas Dynamic Multi-Pathing 6.0.1 Administrator's Guide - AIX September 2012 Veritas Dynamic Multi-Pathing Administrator's Guide The software described in this book is furnished under a license agreement

More information

Windows Host Utilities Installation and Setup Guide

Windows Host Utilities Installation and Setup Guide IBM System Storage N series Windows Host Utilities 6.0.1 Installation and Setup Guide GC52-1295-06 Table of Contents 3 Contents Preface... 7 Supported features... 7 Websites... 7 Getting information,

More information

HP StoreVirtual DSM for Microsoft MPIO Deployment Guide

HP StoreVirtual DSM for Microsoft MPIO Deployment Guide HP StoreVirtual DSM for Microsoft MPIO Deployment Guide HP Part Number: AX696-96344 Published: December 2013 Edition: 5 Copyright 2011, 2013 Hewlett-Packard Development Company, L.P. Revision History Revision

More information

Veritas Storage Foundation 5.0 Dynamic Multi-pathing. Optimizing Availability and Performance in Multi-Vendor Environments May 2007

Veritas Storage Foundation 5.0 Dynamic Multi-pathing. Optimizing Availability and Performance in Multi-Vendor Environments May 2007 Veritas Storage Foundation 5.0 Dynamic Multi-pathing Optimizing Availability and Performance in Multi-Vendor Environments Table of Contents 1 THE IMPORTANCE OF MULTIPLE STORAGE I/O PATHS...5 1.1 MULTIPLE

More information

Veritas Dynamic Multi-Pathing Administrator's Guide

Veritas Dynamic Multi-Pathing Administrator's Guide Veritas Dynamic Multi-Pathing Administrator's Guide Linux DMP 5.1 Rolling Patch 1 Patch 0 Veritas Dynamic Multi-Pathing Administrator's Guide The software described in this book is furnished under a license

More information

1. Revision Page Revision Page 1

1. Revision Page Revision Page 1 1. Revision Page 1 Note: This document contains support information for only the 3 most recent versions of Hitachi Dynamic Link Manager Advanced. If you require support for previous versions, please ask

More information

EMC CLARiiON CX3-20f Setup Guide P/N REV. A02

EMC CLARiiON CX3-20f Setup Guide P/N REV. A02 EMC CLRiiON CX3-20f Setup Guide P/N 300-004-207 REV. 02 Notice Copyright 2006-2007 EMC Corporation. ll rights reserved. Published July, 2007 EMC believes the information in this publication is accurate

More information

EMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15

EMC SAN Copy. Command Line Interface (CLI) Reference P/N REV A15 EMC SAN Copy Command Line Interface (CLI) Reference P/N 069001189 REV A15 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2010 EMC Corporation.

More information

Veritas Dynamic Multi-Pathing Administrator's Guide

Veritas Dynamic Multi-Pathing Administrator's Guide Veritas Dynamic Multi-Pathing Administrator's Guide AIX 5.1 Service Pack 1 Platform Release 1 Veritas Dynamic Multi-Pathing Administrator's Guide The software described in this book is furnished under

More information

HPE StoreVirtual OS v13.5 Release Notes

HPE StoreVirtual OS v13.5 Release Notes HPE StoreVirtual OS v13.5 Release Notes Part Number: 865552-006 Published: May 2017 Edition: 2 Contents Release notes...4 Description... 4 Platforms supported for this release... 4 Update recommendation...4

More information

EMC Fibre Channel with QLogic Host Bus Adapters in the NetWare Environment

EMC Fibre Channel with QLogic Host Bus Adapters in the NetWare Environment EMC Fibre Channel with QLogic Host Bus Adapters in the NetWare Environment P/N 300-001-162 REV A03 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508 -435-1000 www.emc.com Copyright

More information

Disk and FLARE OE Matrix P/N REV A17 February 22, 2011

Disk and FLARE OE Matrix P/N REV A17 February 22, 2011 EMC CX4 Series Storage Systems Disk and FLARE OE Matrix P/N 300-007-437 REV A17 February 22, 2011 To function properly, disks in an EMC CLARiiON system require that each storage processor run minimum revisions

More information

HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes Part number: AA-RWF7J-TE Ninth edition: January 2009 Description

More information

VCS-257.veritas. Number: VCS-257 Passing Score: 800 Time Limit: 120 min. https://www.gratisexam.com/ https://www.gratisexam.com/

VCS-257.veritas. Number: VCS-257 Passing Score: 800 Time Limit: 120 min. https://www.gratisexam.com/ https://www.gratisexam.com/ VCS-257.veritas Number: VCS-257 Passing Score: 800 Time Limit: 120 min Exam A QUESTION 1 SIMULATION How many times will Dynamic Multi-Pathing retry a failed I/O request for a single, active path, by default?

More information

EMC Host Connectivity Guide for Sun Solaris

EMC Host Connectivity Guide for Sun Solaris EMC Host Connectivity Guide for Sun Solaris P/N 300-000-607 REV A11 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2007 EMC Corporation. All rights

More information

Service Description Remote Yearly Maintenance of a Dell EMC Storage Array Environment

Service Description Remote Yearly Maintenance of a Dell EMC Storage Array Environment Service Description Remote early Maintenance of a Dell EMC Storage Array Environment Service SKUs See Appendix A for further information on T1, T2 and T3 Standard Maintenance. Service Overview This service

More information

HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems

HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems Application Notes HP StorageWorks Using the QLogic HBA Driver for Single-path or Multi-path Failover Mode on Linux Systems Product Version: 8.00 Second Edition (January 2005) Part Number: AA RVGWC TE This

More information

EMC PowerPath Family. CLI and System Messages Reference. Version 5.7 P/N REV 10

EMC PowerPath Family. CLI and System Messages Reference. Version 5.7 P/N REV 10 EMC PowerPath Family Version 5.7 CLI and System Messages Reference P/N 300-014-168 REV 10 Copyright 2008 2014 EMC Corporation. All rights reserved. Published in the USA. Published August 2014 EMC believes

More information

EMC Fibre Channel with QLogic Host Bus Adapters in the Windows Environment

EMC Fibre Channel with QLogic Host Bus Adapters in the Windows Environment EMC Fibre Channel with QLogic Host Bus Adapters in the Windows Environment P/N 300-001-164 REV A07 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508 -435-1000 www.emc.com Copyright

More information

SANsurfer FC/CNA HBA Command Line Interface (CLI) Table of Contents

SANsurfer FC/CNA HBA Command Line Interface (CLI) Table of Contents SANsurfer FC/CNA HBA Command Line Interface (CLI) QLogic Corporation. All rights reserved. Table of Contents 1. Package Contents 2. Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3. OS

More information

HP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

HP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes HP StorageWorks QLogic Fibre Channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes Part number: AA-RWFNF-TE Fourteenth edition: April 2009

More information

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide. support.dell.com

VMware Infrastructure Update 1 for Dell PowerEdge Systems. Deployment Guide.   support.dell.com VMware Infrastructure 3.0.2 Update 1 for Dell PowerEdge Systems Deployment Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better

More information

EMC Fibre Channel with QLogic Host Bus Adapters in the Solaris Environment

EMC Fibre Channel with QLogic Host Bus Adapters in the Solaris Environment EMC Fibre Channel with QLogic Host Bus Adapters in the Solaris Environment AUGUST 2002 EMC Corporation 171 South Street Hopkinton, MA 01748-9103 Corporate Headquarters: (508) 435-1000, (800) 424-EMC2 Fax:

More information

Storage / SAN Compatibility Guide For ESX Server 3.5 and ESX Server 3i

Storage / SAN Compatibility Guide For ESX Server 3.5 and ESX Server 3i Storage / SAN Compatibility Guide For and Last Updated: March 12, 2008 What s New Changes since the last edition of this guide include: Added column to Fibre Channel SANs tables. See Fibre Channel SANs

More information

Fibre Channel QLA Driver for Solaris SPARC and x86 Platforms. Table of Contents

Fibre Channel QLA Driver for Solaris SPARC and x86 Platforms. Table of Contents Fibre Channel QLA Driver for Solaris SPARC and x86 Platforms This software license applies only to QLogic customers. QLogic Corporation. All rights reserved. Table of Contents 1. OS Support 2. Software

More information

SANsurfer Fibre Channel Command Line Interface (CLI) Table of Contents

SANsurfer Fibre Channel Command Line Interface (CLI) Table of Contents SANsurfer Fibre Channel Command Line Interface (CLI) QLogic Corporation All rights reserved Table of Contents 1 Package Contents 2 Requirements 2.1 Hardware Requirements 2.2 Software Requirements 3 OS

More information

HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes

HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes HP StorageWorks Emulex fibre channel host bus adapters for ProLiant and Integrity servers using Linux and VMware operating systems release notes Part number: AA-RWF7G-TE Seventh edition: August 2008 Description

More information

EMC Backup and Recovery for Microsoft Exchange 2007

EMC Backup and Recovery for Microsoft Exchange 2007 EMC Backup and Recovery for Microsoft Exchange 2007 Enabled by EMC CLARiiON CX4-120, Replication Manager, and Hyper-V on Windows Server 2008 using iscsi Reference Architecture Copyright 2009 EMC Corporation.

More information

EMC CLARiiON Server Support Products for AIX Server Installation Guide

EMC CLARiiON Server Support Products for AIX Server Installation Guide EMC CLARiiON Server Support Products for AIX Server Installation Guide P/N 300 002 044, Revision A08 January 16, 2007 This guide describes how to install and remove the Navisphere Host Agent, Navisphere

More information

IBM IBM Storage Networking Solutions Version 1.

IBM IBM Storage Networking Solutions Version 1. IBM 000-740 IBM Storage Networking Solutions Version 1 http://killexams.com/exam-detail/000-740 - disk storage subsystem with four (4) total ports - two (2) LTO3 tape drives to be attached Assuming best

More information

EMC CLARiiON iscsi Server Setup Guide for HP-UX

EMC CLARiiON iscsi Server Setup Guide for HP-UX EMC CLARiiON iscsi Server Setup Guide for HP-UX P/N 300 005 050 Revision A03 May 30, 2008 This document describes how to configure iscsi initiator ports and how to set up iscsi security on a server connected

More information

IBM XIV Host Attachment Kit for AIX Version Release Notes

IBM XIV Host Attachment Kit for AIX Version Release Notes IBM XIV Host Attachment Kit for AIX Version 1.8.0 Release Notes First Edition (March 2012) This document edition applies to Version 1.8.0 of the IBM IBM XIV Host Attachment Kit for AIX software package.

More information

HP StoreVirtual Storage Multipathing Deployment Guide

HP StoreVirtual Storage Multipathing Deployment Guide HP StoreVirtual Storage Multipathing Deployment Guide HP Part Number: AX696-96377 Published: January 2015 Edition: 6 Copyright 2011, 2015 Hewlett-Packard Development Company, L.P. Revision History Revision

More information

Considerations for using TSM in a SAN

Considerations for using TSM in a SAN IBM Software Group Considerations for using TSM in a SAN Sept 2002 Revision 5 Steve Strutt, Tivoli Software, IBM UK steve_strutt@uk.ibm.com August 2003 Agenda SAN Exploitation - LAN-Free backup Performance

More information

Table Of Contents. About the EMC Disk Library...1. Hardware and software components...1. EMC Disk Library configuration...3

Table Of Contents. About the EMC Disk Library...1. Hardware and software components...1. EMC Disk Library configuration...3 EDL printed help Table Of Contents About the EMC Disk Library...1 Introduction to the EMC Disk Library...1 Hardware and software components...1 EMC Disk Library configuration...3 About the EMC Disk Library

More information

HP 3PARInfo 1.4 User Guide

HP 3PARInfo 1.4 User Guide HP 3PARInfo 1.4 User Guide Abstract This guide provides information about installing and using HP 3PARInfo. It is intended for system and storage administrators who monitor and direct system configurations

More information

IBM XIV Host Attachment Kit for HP-UX. Version Release Notes. First Edition (May 2011)

IBM XIV Host Attachment Kit for HP-UX. Version Release Notes. First Edition (May 2011) IBM XIV Host Attachment Kit for HP-UX Version 1.6.0 Release Notes First Edition (May 2011) First Edition (May 2011) This document edition applies to Version 1.6.0 of the IBM XIV Host Attachment Kit for

More information

HP StorageWorks Enterprise Virtual Array (EVA) online controller firmware upgrades white paper

HP StorageWorks Enterprise Virtual Array (EVA) online controller firmware upgrades white paper HP StorageWorks Enterprise Virtual Array (EVA) online controller firmware upgrades white paper Introduction... 2 Definition of terms... 2 Understanding how the feature works... 3 Considerations for systems

More information

EMC SAN Copy Command Line Interface P/N REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA

EMC SAN Copy Command Line Interface P/N REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA EMC SAN Copy Command Line Interface P/N 069001189 REV A14 EMC Corporation Corporate Headquarters: Hopkinton, MA 01748-9103 1-508-435-1000 www.emc.com Copyright 2006-2009 EMC Corporation. All rights reserved.

More information

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information...

ProLiant Cluster HA/F500 for Enterprise Virtual Array Introduction Software and Hardware Pre-Checks Gathering Information... Installation Checklist HP ProLiant Cluster F500 for Enterprise Virtual Array 4000/6000/8000 using Microsoft Windows Server 2003, Enterprise Edition Stretch Cluster May 2005 Table of Contents ProLiant Cluster

More information

HP StorageWorks Performance Advisor. Installation Guide. Version 1.7A

HP StorageWorks Performance Advisor. Installation Guide. Version 1.7A HP StorageWorks Performance Advisor Installation Guide Version 1.7A notice Copyright 2002-2004 Hewlett-Packard Development Company, L.P. Edition 0402 Part Number B9369-96068 Hewlett-Packard Company makes

More information

HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system.

HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system. HS22, HS22v, HX5 Boot from SAN with QLogic on IBM UEFI system. Martin Gingras Product Field Engineer, Canada mgingras@ca.ibm.com Acknowledgements Thank you to the many people who have contributed and reviewed

More information