Digital Modules AS-i, IP67, M12
|
|
- Noel Webster
- 5 years ago
- Views:
Transcription
1 Digital Modules, IP67, M1 x connectors for color LEDs per output, state (yellow), overload (red) BWU487 / BWU547 / BWU55 / BWU594 / BWU60 / BWU713 / BWU75 / BWU78 (Figure similar) BWU617 / BWU619 / BWU66 / BWU645 / BWU651 / BWU65 / BWU770 / BWU684 Housing, construction: IP67, M1 Housing 4 x M1 8 x M1 Inputs digital Outputs digital M1 wiring 1 Input voltage (sensor supply) Output voltage (actuator supply) 3 4 Y out of 4 Single out of 4 Single out of AUX 4 4 Y out of out of AUX 4 4 Mixed out of out of AUX 4 Y out of AUX 4 Y out of AUX 4 Y out of AUX 4 4 Y out of out of AUX 4 4 Single out of out of AUX 4 4 Single out of out of AUX 4 4 Single out of AUX out of AUX 8 Y out of AUX 8 Y out of 8 8 Y out of out of AUX 8 Y out of AUX connection 4 via M1 address 5 Max. output current Art. no. 1 AB slave BWU55 1 AB slave BWU60 1 AB slave BWU75 1 AB slave 500mA BWU487 1 AB slave 500mA BWU547 1 single slave 1A BWU713 1 AB slave 1A BWU594 1 AB slave A BWU78 1 AB slave 1A BWU66 1 AB slave 1A BWU617 1 Single slave 1A BWU684 1 AB slave 1A BWU645 AB slaves BWU770 AB slaves BWU651 AB slaves 1A BWU619 AB slaves 1A BWU65 Replacement, version.0: Single slaves (digital) are also working with the first generation Masters. We reserve the right to change any data Mannheim, page 1
2 Digital Modules, IP67, M1 1 M1 wiring: either as singlewiring or Ywiring Single-wiring Y-wiring V I nc +4V nc Input voltage (sensor supply): inputs are supplied by or by AUX (auxiliary 4V power). If supplied by, inputs can neither be connected to earth nor to external potential. 3 Output voltage (actuator supply): outputs are supplied by or by AUX (auxiliary 4V power). If supplied by, inputs can neither be connected to earth nor to external potential. 4 connection: the connection to as well as to AUX (auxiliary 4V power) is either made via yellow with piercing technology or via M1 socket. 5 address: AB slave (max. 6 AB slaves/ network), AB slaves (max. 31 modules with AB slaves), Single slaves (max. 31 Single slaves/per network), mixed use allowed V I n nc +4V I n+1 page Mannheim, We reserve the right to change any data
3 Digital Modules, IP67, M1 Article no. Connection /AUX connection Periphery connection M1, Y-wiring Profile S-0.A.E (ID1=7 default) Address BWU55 BWU60 BWU75 BWU547 BWU487 BWU713 BWU594 BWU78 and piercing M1 Mixed M1, Y-wiring 1 AB slave S-7.A.7 (ID1=7 fixed) S-7.F.E (ID1=F default) 1single slave S-7.A.7 (ID1=7 fixed) 1 AB slave Operating voltage 30V ( V) Required Master profile M3 M4 M0 M4 As of specification Max. current consumption 165mA 35mA Max. current consumption without sensor / 45mA 35mA actuator supply AUX Voltage 4V (18 30V) Max. AUX current consumption 1A A 3A 8A Input Number 4 Power supply supply out supply out of of AUX supply out of Power supply of attached sensors max. 10mA max. 1A max. 10mA Switching threshold U<5V (low) U>15V (high) Output Number 4 Power supply supply out of AUX Max. output current 1A A per 500mA per output ( 3A max.) output 1 Display LED ASI (green) on: voltage on, flashing: voltage on, but peripheral fault 3 or address 0 Off: no voltage LED FLT/FAULT (red) on: slave address 0 or slave offline flashing: peripheral fault 3 off: slave online LED ASI/FLT 1 (red/green) LED ASI/FLT (red/green) LED AUX (green) on: 4V DC off: no 4V DC AUX LEDs In / In+1 (yellow) state of inputs I1 / I... I3 / I4: at least 1 input of input pair is on LEDs On / On+1(yellow) state of output O1/O...O3/O4: at least 1 output of output pair is on LEDs I1... In (yellow) state of inputs I1... I4 LEDs O1... On (yellow) state of outputs O1... O4 We reserve the right to change any data Mannheim, page 3
4 Digital Modules, IP67, M1 Article no. Environment Applied standards EN EN EN Operating temperature -30 C +70 C Storage temperature -30 C +85 C Protection category IP67 (DIN EN 60 59) Maximum tolerable shock and vibration stress Isolation voltage Dimensions (W / H / D) in mm Weight BWU55 BWU60 BWU75 BWU547 BWU487 BWU713 BWU594 BWU78 15g, T 11ms Hz, 0,5mm amplitude 500V 45 / 80 / 4 100g page 4 Mannheim, We reserve the right to change any data
5 Digital Modules, IP67, M1 Artikel Nr. BWU66 BWU617 BWU684 BWU645 BWU770 BWU651 BWU619 BWU65 Connection /AUX connection Periphery connection Profile address Operating voltage Required Master profile Since specification Max. current consumption Max. current consumption without sensor / actuator supply AUX Voltage M1, Y-wiring and piercing M1 and piercing S-7.A.7 (ID1=7 fixed) 1 AB slave M1 S-7.0.E (ID1=F default) 1 single slave S-7.A.7 (ID1=7 fixed) Slave 1: S-0.A.E (ID1=7 default), Slave : S-0.A.E (ID1=6 default) M1, Y-wiring 1 AB slave AB slaves 30V ( V) Slave 1: S-7.A.7 (ID1=7 fixed), Slave : S-7.A.7 (ID1=6 default) M4 M0 M4 M3 M mA 35mA 310mA 60mA 45mA 35mA 70mA 60mA 4V (18 30V) 4V (18 30V) Max. AUX current consumption 3A 6A Input Number 4 8 Power supply supply out of supply out of AUX supply out of Power supply of attached sensors max. 10mA max. 1A 40mA Switching threshold Output U<5V (low) U>15V (high) Number 4 8 Power supply supply out of AUX supply out of AUX Max. 1A ( 3A max. for O1-O4 output current 1 1A ( 3A max.) + 3A max. for O5-O8) Display LED ASI (green) on: voltage on flashing: voltage on, but peripheral fault 3 or address 0 off: no voltage LED FLT/FAULT (red) LED ASI/FLT 1 (red/green) LED ASI/FLT (red/green) LED AUX (green) on: slave address 0 or slave offline flashing: peripheral fault 3 off: slave online on: 4V DC AUX off: no 4V DC AUX green: slave online red: no data exchange yellow/red flashing: address 0 red/green flashing: peripheral fault 3 green: slave online red: no data exchange yellow/red flashing: address 0 red/green flashing: peripheral fault 3 red flashing: slave is switched off, because slave 1 is addressed 0 on: 4V DC AUX off: no 4V DC AUX We reserve the right to change any data Mannheim, page 5
6 Digital Modules, IP67, M1 Artikel Nr. BWU66 BWU617 BWU684 BWU645 BWU770 BWU651 BWU619 BWU65 LEDs In / In+1 (yellow) LEDs On / On+1 (yellow) state of inputs I1 / I... I3 / I4: at least 1 input of input pair is on state of outputs O1 / O... O7 / O8: at least 1 output of output pair is on LEDs I1... In (yellow) state of inputs I1... I4 state of inputs I1... I8 LEDs O1... On (yellow) state of outputs O1... O4 Umwelt Applied standards EN EN EN Operating -30 C +70 C temperature Storage -30 C +85 C temperature Protection cat. IP67 (DIN EN 60 59) Max. tolerable shock and vibration stress Isolation voltage Dimensions (W / H / D) in mm Weight 1 D Derating output current e r Current a t A i n 8 g g, T 11ms Hz, 0,5mm amplitude 500V 60 / 151 / 31 00g state of outputs O1... O C Operating temperature S Derating power supply of attached sensors e n Current s o ma r40/ v 10 e r s 160/ o 80 r g u n g C Operating temperature 3 see Installation instruction /Manual page 6 Mannheim, We reserve the right to change any data
7 Digital Modules, IP67, M1 Programming Bit assignment Bit D0 D1 D D3 BWU487 / BWU547 / BWU55 / BWU617 / BWU60 / BWU66 / BWU645 / BWU684 / BWU75 BWU619/ BWU651 / BWU770 Input I1 I I3 I4 Slave 1: I1 Slave 1: I Slave 1: I3 Slave 1: I4 Slave : I5 Slave : I6 Slave : I7 Slave : I8 Output BWU487 / BWU547 / BWU594 / BWU617 / BWU66 / BWU645 / O1 O O3 O4 BWU684 / BWU713 / BWU78 BWU619 / BWU65 Slave 1: O1 Slave 1: O Slave 1: O3 Slave 1: O4 Slave : O5 Slave : O6 Slave : O7 Slave : O8 Parameter bit P0 P1 P P3 BWU487 / BWU547 / BWU594 / BWU617 / BWU619 / BWU66 / BWU645 / BWU65 / BWU684 / BWU713 / BWU78 BWU55 / BWU60 / BWU651 / BWU770 / BWU75 0= off / 1= on (Watchdog) 0= on / 1= off (data input filter 18μs) 0= off / 1= on (peripheral fault) 0= on / 1= off (synchronous I/O mode) not used We reserve the right to change any data Mannheim, page 7
8 Digital Modules, IP67, M1 Pin assignment Signal name Ix Ox 4V ext out 0V ext out 4V out of 0V out of AS- Explanation digital input x digital output x power supply, out of external voltage, positive pole (AUX, acuator supply) power supply, out of external voltage, negative pole (AUX, acuator supply) power supply, out of, positive pole (sensor supply) power supply, out of, negative pole (sensor supply) Connections Article no. M1 connection Marking Pin1 Pin Pin3 Pin4 Pin5 BWU487 X1 I1/I 4V out of I 0V out of I1 nc X O1/O 4V ext out O 0V ext out O1 nc X3 I3/I4 4V out of I4 0V out of I3 nc X4 O3/O4 4V ext out O4 0V ext out O3 nc X X1 X3 connection for adressing device X1 I1/O1 4V ext out O1 0V ext out I1 nc X4 X I/O 4V ext out O 0V ext out I nc BWU547 X3 I3/O3 4V ext out O3 0V ext out I3 nc X4 I4/O4 4V ext out O4 0V ext out I4 nc connection for adressing device BWU594 BWU713 BWU78 X1 O1 0V ext out O 0V ext out O1 nc X O 0V ext out nc 0V ext out O nc X3 O3 0V ext out O4 0V ext out O3 nc X4 O4 0V ext out nc 0V ext out O4 nc connection for adressing device X1 I1 4V out of I 0V out of I1 nc X I 4V out of nc 0V out of I nc BWU55 X3 I3 4V out of I4 0V out of I3 nc X4 I4 4V out of nc 0V out of I4 nc connection for adressing device X1 I1 4V out of nc 0V out of I1 nc X I 4V out of nc 0V out of I nc BWU60 X3 I3 4V out of nc 0V out of I3 nc X4 I4 4V out of nc 0V out of I4 nc connection for adressing device X1 I1 4V ext out nc 0V ext out I1 nc X I 4V ext out nc 0V ext out I nc BWU75 X3 I3 4V ext out nc 0V ext out I3 nc X4 I4 4V ext out nc 0V ext out I4 nc connection for adressing device page 8 Mannheim, We reserve the right to change any data
9 Digital Modules, IP67, M1 Connections Article no. M1 connection Marking Pin1 Pin Pin3 Pin4 Pin5 X1 I1 4V out of nc 0V out of I1 nc X1 X X I 4V out of nc 0V out of I nc BWU617 BWU684 X3 I3 4V out of nc 0V out of I3 nc X4 I4 4V out of nc 0V out of I4 nc X5 O1 0V ext out nc 0V ext out O1 nc X6 O 0V ext out nc 0V ext out O nc X3 X5 X4 X6 X7 O3 0V ext out nc 0V ext out O3 nc X8 O4 0V ext out nc 0V ext out O4 nc connection for adressing device X1 I1/I 4V out of I 0V out of I1 nc X I3/I4 4V out of I4 0V out of I3 nc X3 I5/I6 4V out of I6 0V out of I5 nc X4 I7/I8 4V out of I8 0V out of I7 nc BWU619 X5 O1/O 0V ext out O 0V ext out O1 nc X6 O3/O4 0V ext out O4 0V ext out O3 nc X7 O5/O6 0V ext out O6 0V ext out O5 nc X8 O7/O8 0V ext out O8 0V ext out O7 nc connection for adressing device X X8 X1 I1 4V out of I 0V out of I1 nc X I 4V out of nc 0V out of I nc X3 I3 4V out of I4 0V out of I3 nc X4 I4 4V out of nc 0V out of I4 nc BWU66 X5 O1 0V ext out O 0V ext out O1 nc X6 O 0V ext out nc 0V ext out O nc X7 O3 0V ext out O4 0V ext out O3 nc X8 O4 0V ext out nc 0V ext out O4 nc connection for adressing device X1 I1 4V out of I 0V out of I1 nc X I 4V out of nc 0V out of I nc X3 I3 4V out of I4 0V out of I3 nc X4 I4 4V out of nc 0V out of I4 nc BWU651 X5 I5 4V out of I6 0V out of I5 nc X6 I6 4V out of nc 0V out of I6 nc X7 I7 4V out of I8 0V out of I7 nc X8 I8 4V out of nc 0V out of I8 nc connection for adressing device X1 O1 0V ext out O 0V ext out O1 nc X O 0V ext out nc 0V ext out O nc X3 O3 0V ext out O4 0V ext out O3 nc X4 O4 0V ext out nc 0V ext out O4 nc BWU65 X5 O5 0V ext out O6 0V ext out O5 nc X6 O6 0V ext out nc 0V ext out O6 nc X7 O7 0V ext out O8 0V ext out O7 nc X8 O8 0V ext out nc 0V ext out O8 nc connection for adressing device We reserve the right to change any data Mannheim, page 9
10 Digital Modules, IP67, M1 Connections Article no. M1 connection Marking Pin1 Pin Pin3 Pin4 Pin5 X1 I1 4V ext out I 0V ext out I1 nc X I 4V ext out nc 0V ext out I nc X3 I3 4V ext out I4 0V ext out I3 nc X4 I4 4V ext out nc 0V ext out I4 nc BWU770 X5 I5 4V ext out I6 0V ext out I5 nc X6 I6 4V ext out nc 0V ext out I6 nc X7 I7 4V ext out I8 0V ext out I7 nc X8 I8 4V ext out nc 0V ext out I8 nc connection for adressing device Connections Article no. BWU645 M1 connection Marking Pin1 Pin Pin3 Pin4 Pin5 X1 I1 4V ext out nc 0V ext out I1 nc X I 4V ext out nc 0V ext out I nc X3 I3 4V ext out nc 0V ext out I3 nc X4 I4 4V ext out nc 0V ext out I4 nc X5 O1 0V ext out nc 0V ext out O1 nc X6 O 0V ext out nc 0V ext out O nc X7 O3 0V ext out nc 0V ext out O3 nc X8 O4 0V ext out nc 0V ext out O4 nc X9 + 0V ext in - 4V ext in X1 X3 X5 X7 X X4 X6 X8 X Accessories: substructure module for 4-channel module in 45 mm-housing (art. no. BW349 substructure module (CNOMO) 4-channel module in 45 mm-housing (art. no. BW350) substructure module (CNOMO) for 8-channel module in 60 mm-housing (article no. BW351 Protection caps for unused M1 sockets (article no. BW368) page 10 Mannheim, We reserve the right to change any data
AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital
More informationAS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12
More informationDigital Modules AS-i in IP20, 22,5 mm
Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3)
More informationAnalog Modules AS-i, IP67, M12
Analog Modules, M12 2 x 2 connectors for compact housing, IP67 (Figure similar) Figure Type Inputs analog Outputs analog M12 connection Input voltage (sensor supply) Output voltage (actuator supply) (2)
More informationActive Distributors AS-i Safety, Active Distributors AS-i
Active Distributors Safety, Active Distributors x connectors for Periphery connection via, M cable sockets or push in terminals (Figure similar) Figure Type Inputs Safety, SIL, Cat. x 9 mm, -channels Safety
More informationAS-i Safety Input Modules (M12), IP67
Input Modules (), IP67 Input Modules (), IP67 for opto, floating contacts or complementary switch Applications up to category 4/PLe/SIL 3 (Figure similar) Figure Type Inputs, SIL 3, cat. 4 4 x, 4 x, 4
More informationAS-i 3.0 Motor modules
AS-i 3.0 motor modules for two 4 V motorized rollers e.g. Interroll (EC00, EC300, EC310) or RULMECA (RDR BL-) or Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) slaves in one module 1 Single Slave with - s - digital
More informationAS-i 3.0 motor module
3.0 motor module 3.0 motor module for two 4 V motorized rollers Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) with 4 binary and analog outputs Mixed input/output slave Speed setting of parameter Protection category
More informationAnalog Modules AS-i IP65, M12
Plug and Play as simply as digital AS-i I/O BWU1361 / BWU1362 / BWU1722 / BWU1853 / BWU1917 / BWU1363 / BWU2532 / BWU1359 / BW1360 / BWU1893 BWU1894 BWU1895 BWU1963 BWU1964 Housing, construction: IP65,
More informationAS-i 3.0 motor modules
AS-i 3.0 4I/4O modules for two 4 V motorized rollers e.g. Interroll (EC00, EC300 or EC30) or RULMECA (RDR BL-) or Rollex (type 840) with binary and analog outputs Mixed input/output slave Speed setting
More informationActive Distributors ASi Safety, IP67
x connectors for profile cable Periphery connection via M8 cable sockets M cable sockets (Figure similar) Figure Type Inputs, SIL 3, Cat. 4 9 mm 9 mm 9 mm 9 mm channels channels channels channels Inputs
More informationAS-i Safety Output Module, IP20
a AS-i Safety Output Module Safe outputs and standard inputs in one module Protection category IP20 Figure Housing Inputs digital Outputs Safety, SIL3, cat.4 Input voltage (sensor supply) 1 Output voltage
More informationPCB AS-i modules, board based solutions
Special variants on request (Figure similar) PCB modules, board based solutions Circuit Inputs board dimensions digital Inputs analog Outputs digital Connection Coated LED status display 4 Input voltage
More informationAS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O
ext. in ext. in Safety Output Module with Safety and standard I/O in one module Electronic safety output Additional 3 standard inputs, 1 EDM input, 2 outputs IEC 61508 SIL 3, EN ISO 13849-1 PLe Cat 4,
More informationEncoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes
w AS-i Speed Monitor for sine/cosine encoder for HTL encoder for SSI encoder for TTL encoder for sensors for 2 fast electronic safe outputs 128 devices Supplied out of AS-i and external 24 V (figure similar)
More informationAS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input
Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20
More informationAS-i 3.0 Sercos Gateways with integrated Safety Monitor
AS-i 3.0 Sercos Gateways with Safety on Sercos and Safe Link in one device up to 456 Devices Safely monitoring safety drives with Safety on Sercos 2 / 1 AS-i master, Sercos slave switch integrated (figure
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways 2 AS-i Masters, 1 PROFIBUS Slave Up to 32 release circuits up to 6 CAT4, SIL 3 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous Up to 32
More informationAS-i 3.0 PROFINET-Gateways with integrated Safety Monitor
AS-i 3.0 PROFI Gateways with Master, 1 PROFI Slave Up to 32 release circuits up to 6 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i outputs Multiple
More informationAS-i Safety Analog Input Module, IP20
2 safe inputs in one module: 4... 20 ma or 0... 10 V or Pt100 or thermocouple (type J / K / N / R / S) Applications up to category 4/PLe/SIL 3 (figure similar) The AS-i Safety Input Module for analog inputs
More informationAS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input
ext. in ext. in AS-i Safety Relay Output Module with Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V Additionally 1 EDM input, 1 x
More informationArticle no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC
Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 AS-i networks Operation using a single Monitor configuration! Monitor processes safety slaves on two AS-i networks
More informationAS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor
AS-i 3.0 -Gateways 2 / 1 AS-i Master, -Slave (1) switch integrated Up to 64 release circuits up to circuits SIL 3, cat. 4 on the Monitor, relays or fast Safe AS-i outputs are supported up to 32 independent
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via or AS-i 3.0 Gateways, safe via or 2 / 1 Master, / Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up to 6 CAT4, SIL 3 safe output
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
via PROFI or PROF AS-i 3.0 Gateways, via PROF or PROFI 22 / 1 Master, PROF / PROFI Slave AS-i Safety input slaves report via AS-i Safety output slaves switch via Up to 32 release circuits up to 6 CAT4,
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 Master, Slave 1 AS-i Safety Monitor for 2 AS-i networks Operation using a single Monitor configuration! Monitor processes safety slaves on two AS-i networks Coupling
More informationAS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor
AS-i 3.0 -Gateways 2 / 1 AS-i Master, -Slave 1 switch integrated up to 32 release circuits up to 6 release circuits SIL 3, cat. 4 on the Monitor Safe AS-i outputs are supported up to 32 independent AS-i
More informationAS-i 3.0 EtherCAT Gateways with integrated Safety Monitor
AS-i 3.0 EtherCAT Gateways with 2 / 1 Master, EtherCat Slave 1 Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous
More informationOperating instructions. ProcessLine analogue module AC / / 2012
Operating instructions ProcessLine analogue module AC2916 739089 / 01 06 / 2012 Contents 1 Safety instructions... 3 2 Functions and features... 4 3 Operating and display elements... 4 4 Electrical connection...
More informationAS-Interface I/O Module
AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard
More informationInstallation Instructions Temperature transmitter TAA /00 06/2011
Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationOperating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017
Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC5274 7390889/00 07/2017 Contents 1 Functions and features...3 2 Operating and display elements...3 3 Installation...4
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationDevice manual AS-i PowerSwitch ZB0028 ZB0040
Device manual AS-i PowerSwitch ZB0028 ZB0040 System AS-i Page 1 of 16 Device manual POWERSWITCH ZB0028 ZB0040 Date: 04/02/02 Contents 1. Views... 3 1.1 Top view... 3 1.2 Front view... 4 1.3 Bottom view...
More informationVersaMax IP Input Module
Module is used to accept digital input signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature Storage temperature Operating/storage humidity 60mm
More informationDiagnostics (Logical) Diagnostics (Physical)
Analog Output Stations Analog on AS-I IP 20 for In-The-Cabinet Powered by AS-I or Auxiliary Supply Voltage and Current Outputs ASI-AO-2 BW1412 ASI-AO-2A BW1727 Electrical Operating Current:
More informationFLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet
Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system
More informationBNI IOL-104-S01-Z012-C02
BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical
More informationMagnetically Actuated Safety Interlock Switches
Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic
More informationSafety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C
r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches MA Series MA For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Magnetically Actuated Safety
More informationOperating instructions AC010S Compact AS-i E-STOP safety module
Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................
More informationTABLE OF CONTENTS AS-INTERFACE
TABLE OF CONTENTS AS-Interface module AAAA...2 AS-Interface module EEAA...4 AS-Interface module EEEE...6 AS-Interface coupler module PGK...8 AS-Interface coupler module FKK...10 AS-Interface coupler module
More informationBNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide
BNI IOL302000Z013 BNI IOL302S01Z013 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ013 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions
More informationBNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide
BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax
More informationBNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide
BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ026 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationDiagnostics (Logical)
Input Station Rugged, Fully Potted Stations IP 67 Protection Flat and Round Cable Support AS-I Version 2.1 FAS4-S0400 Electrical Operating Current:
More informationCompact performance. Brief description. CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8. English e [ ]
Compact performance Brief description CPV valve terminal with AS-Interface type CPV..-GE- ASI-8E8A-Z M8 English 8080251 2017-11e [8080244] Translation of the original instructions Documentation on the
More informationInductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3-wire, plastic housing
Inductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3wire, plastic housing Dimensions in mm 121 PG 13,5 101 27 Features Can be installed flush or nonflush in metal Variable switching
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)
More informationGFK-2415A March Type of sensor connection
VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:
More informationOperating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015
Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC5294 80226775/00 02/2015 Contents 1 Preliminary note...3 2 Safety instructions...3 3 Functions
More information4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus
4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output
More informationSTBEHC3020KC counter kit STB - 1 CH Hz - 2 I
Characteristics counter kit STB - 1 CH - 0..40000 Hz - 2 I Main Range of product Product or component type Number of channels 1 Complementary Kit composition Counting input number 2 Counting frequency
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics
More informationBMXEHC0200 high speed counter module M340-2 channels
Product data sheet Characteristics BMXEHC0200 high speed counter module M340-2 channels Complementary Counter functions Cycle time Isolation voltage Input type Input voltage limits Input current Voltage
More informationSystem manual AS-i safety monitor AC041S /00 05/2013
System manual AS-i safety monitor AC041S UK 7390926/00 05/2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions and features...6 5 Structure
More informationMANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0
FACTORY AUTOMATION MANUAL VAA-2E2A-G12-SAJ/EA2L Original Instructions Version 1.0 SAFETY AT WORK With regard to the supply of products, the current issue of the following document is applicable: The General
More informationHandbook ASI-PRG-ADR. AS-Interface Addressing Device. Festo AG & Co de 0004a
Handbook ASI-PRG-ADR AS-Interface Addressing Device Festo AG & Co. 360 039 de 0004a AS-Interface is a registered Trademark of the AS-International Association We recognise a duty to make a contribution
More informationVersaPoint I/O Module
Output 24VDC Positive Logic 0.5A 14 Points Module is used to output 24VDC digital signals. Module Specifications Housing dimensions (width x height x depth) Connection style Operating temperature 48.8mm
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics
More informationILB DN 24 DI16 DO16. Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs. AUTOMATIONWORX Data Sheet 6885_en_05
Inline Block IO Module for DeviceNet With 16 Digital Inputs and 16 Digital Outputs AUTOMATIONWORX Data Sheet 6885_en_05 PHOENIX CONTACT - 03/2007 Description The ILB DN 24 DI16 DO16 module is designed
More informationOperating instructions Memory plug E /02 11/2011
Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5
More informationMaking Hazardous Operations Safe and Productive
NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series
More informationRSTI-EP Slice I/O. Digital Output Module
GFK-2959B December 2015 RSTI-EP Slice I/O Digital Output Modules EP-2214, EP-2614, EP-2634, EP-2218, EP-225F Relay Output Module Solid-state Relay Output Module EP-2814 Module Status LED Channel Status
More informationMain contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible
Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide
More informationAS-Interface INSTALLATION GUIDE, TIPS AND TRICKS
AS-Interface INSTALLATION GUIDE, TIPS AND TRICKS AS-Interface Installation guide Tips and Tricks 2 Index AS-Interface General Features 4 AS-Interface Key Features 7 Selecting the Cable 8 Cable Routing
More informationBNI IOL Z012. User s Guide
BNI IOL205000Z012 User s Guide Balluff Network Interface / BNI IOL205000Z012 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations
More informationAS-i Safety Relay Output Module with Diagnostic Slave
AS-i Safety Relay Output Module with Diagnostic Slave User Manual...supports the requirements for AS-i Safety up to SIL3 Revision date: 2016-03-9 Subject to modifications without notice. Generally, this
More informationXPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output
Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation
More informationPeristaltic Cased Tube Pump
Peristaltic Cased Tube Pump Selectable Output Control Functionality and Setup Version 1.0v-11/2016 Print-No. 01 Table of Contents 1. Introduction 2. Powering the Input/Output Port 2.1 Wiring for Local
More informationOperating instructions valve control box AS-i
THIS LEAFLET SHOULD BE KEPT IN A SAFE PLACE FOR REFERENCE Operating instructions valve control box AS-i 1 System description The Norgren Herion valve control box is used for controlling pneumatic swivel
More informationSALES NUMBER NUMBER OF BEAMS PROTECTIVE HEIGHT
SECTION 21 182 Safety Light Curtains Type: SLC-F Finger (14mm) FEATURES: Resolution: 14mm Protective height: 160mm to 1040mm Type 4 according to IEC61496-1 and -2 ORDERING INFORMATION: SALES OF BEAMS PROTECTIVE
More informationDescription. Features. Ultrasonic Sensors 873P Analog or Discrete Output INTRODUCTION. 873P Analog Output18 mm. 873P Discrete Output30 mm
INTRODUCTION 873P Analog Output18 mm 873P Discrete Output30 mm Description Bulletin 873P Ultrasonic Sensors are self contained solid state devices designed for noncontact sensing of solid and liquid objects.
More informationSX5A AS-Interface(Communication Terminal and Repeater)
SXA AS-Interface(Communication Terminal and Repeater) AS-Interface Communication Terminals (Slave Modules) IP67 I/O Module AS-Interface Ver..1 compliant, capable of connecting 6 slaves Compatible with
More informationG9SX-GS. Safety Guard Switching Unit. A Safety Measure for Hazardous Operations That Does Not Lower Productivity. Auto Switching Function
Safety Guard Switching Unit CSM DS_E_6_1 A Safety Measure for Hazardous Operations That Does Not Lower Productivity Two functions support two types of application: Auto switching: For applications where
More informationMiniAmp. Electronics & Software. Miniature Charge Amplifier. Type 5030A...
Electronics & Software MiniAmp Type 5030A... Miniature Charge Amplifier The MiniAmp Type 5030A is a single channel, industrial charge amplifier, which converts the charge signal from piezoelectric sensors
More informationSensor boxes SRBG Key features
Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn
More informationOnline data sheet RE13-SAC RE1 NON-CONTACT SAFETY SWITCHES
Online data sheet RE13-SAC RE1 A B C D E F H I J K L M N O P Q R S T Detailed technical data Features System part Sensor principle Ordering information Other models and accessories Number of N/O contacts
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More information4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection
4.8 Digital Input/Output Module 07 DC 9 3 configurable digital inputs/outputs, 4 V DC, electrically isolated in groups, outputs can be loaded with 500 ma, CS31 system bus 1 3 4 1 Fig. 4.8-1: Digital input/output
More informationProtected VARAN Digital Mixed Module PVDM 086
PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Protected VARAN Digital Mixed Module PVDM 086 The PVDM 086 Protected VARAN Digital Mixed Module has eight +24 V/2 A digital outputs (positive switching) that
More informationDIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:
DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:
More informationAS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45
Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages
More informationCommunication & Networking
SXA AS-Interface SXA AS-Interface (Communication Terminal and Repeater) AS-Interface Communication Terminals (Slave Modules) IP67 I/O Module AS-Interface Ver.. compliant, capable of connecting 6 slaves
More information02/11/2015
35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More informationSK TU4-IOE-M12-C Part Number
SK TU4-IOE-M2-C Part Number 275 28 256 IO Extension Only qualified electricians are allowed to install and commission the module described below. An electrician is a person who, because of their technical
More informationVEO. V2UF230V10 Art.Nr.: TECHNICAL DATA
Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after
More informationEH-RIO IP67 Profibus-DP I/O modules
Installation Instructions EH-RIO IP67 Profibus-DP I/O modules (RIO-PBXDP8M12, -PBXDP8M8, -PBYTP8M12, -PBYTP8M8, -PBXYP8M12, -PBXYP8M8) M12 Style Connectors M8 Style Connectors 43819 The EH-RIO IP67 Profibus-DP
More informationEtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus
EtherNet/IP Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module
More informationTM221ME32TK controller M IO transistor PNP Ethernet
Product data sheet Characteristics TM221ME32TK controller M221 32 IO transistor PNP Ethernet Complementary Main Discrete I/O number 32 Number of I/O expansion module Supply voltage limits Inrush current
More information