AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

Size: px
Start display at page:

Download "AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports"

Transcription

1 / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital 4x 4x 8x M 4 x 4x M wiring class A class A Class B Input voltage (sensor supply) out of AUX out of out of Output voltage (actuator supply) out of AUX out of out of connection 3 address 4 single single single Max. output current Art. no. 500 ma BWU853 0 ma BWU ma Input voltage (sensor supply) Inputs are supplied by or by AUX (auxiliary 4 V power). If supplied by, inputs can neither be connected to earth nor to external potential. Output voltage (actuator supply) The supply of the outputs is made by or by AUX (auxiliary 4 V power). By supply out of there is no connection to earth or external potential allowed. 3 connection The connection to as well to AUX (auxiliary 4 V power) is made via yellow or black with piercing technology or via M socket (in IP0 via clamps). 4 address AB slave (max. 6 AB / network), AB (max. 3 modules with AB ), single (max. 3 single / network), mixed use allowed (upon request, are available with specific AS-slave profiles). 5 Only on request. We reserve the right to change any data Mannheim, page

2 / IO-Link Module, Article no. BWU853 Connection /AUX connection and piercing Periphery connection M Length of connector cable I/O: max. 0 m IO-Link Number 4 ports Data rate COM / COM / COM3 IO-Link revision. Profile slave : S (ID=F default) slave : S (ID=E default) Address single Operating voltage 30 V (8 3.6 V) 30 V (4 3.6 V) Required master profile M4 Since specification 3.0 Max. current consumption 50 ma 00 ma Max. current consumption without 50 ma 80 ma sensor / actuator supply AUX Voltage 4 V (8 30 V) Max. current consumption 4 A Input Number 4 (via ) + 4 (via ) Power supply out of AUX out of Supply of attached sensors 500mA per port, (sensors + outputs) max. A (sensors + outputs) max. 0 ma 3 Switching threshold U<5 V (low) U>5 V (high) Output Number 4 (via ) Power supply out of AUX out of Max. output current 500 ma per port, (sensors + outputs) max. A (sensors + outputs) max. 0 ma 3 Display LED ASI (green) LED FLT/FAULT (red) LED AUX (red/green) LEDs P... Pn (red/green) on: no data exchange flashing: AUX voltage missing, overload sensor supply, overload output or IO-Link error on: voltage on off: no voltage green: AUX voltage OK red: AUX voltage < 8 V state of P... P4 green: IO-Link communication OK yellow: switching signal at input or output red: IO-Link communication error on: no data exchange flashing: overload sensor supply, overload output or IO-Link error page Mannheim, We reserve the right to change any data

3 / IO-Link Module, Article no. BWU853 Environment Applied standards EN EN EN 6 3- Operating temperature Storage temperature Housing plastic, for DIN rail mounting Protection cat. (EN 6059) Max. tolerable shock and vibration stress Isolation voltage 5 g, T ms Hz, 0,5 mm amplitude 500 V Dimensions (W / H / D in mm) 60 / 5 / 3 Weight 00 g Derating total current out of AUX I Σ (AUX) A BWU853 Derating total current per port I Port max. A 0, We reserve the right to change any data Mannheim, page 3

4 / IO-Link Module, 3 Derating total current out of I Σ (Sensors and outputs) ma Programming bit assignment Bit D0 D D D3 Input BWU853 / Slave : P-I Slave : P-I Slave : P3-I Slave : P4-I Output BWU853 / adjustable adjustable BWU853 / Parameter bit P0 P P 0=data mapping 0= IO-Link parameter 0= manual setting of adjustable backup active port configuration = default data mapping activated = no IO-Link parameter backup Via process data mapping and IO-Link gateway configuration adjustable. Plug and Communication mode is not usable with digital outputs (actuator without IO-Link). Digital inputs are frozen during IO-Link wakeup sequence. = plug and comm mode active Pin assignment Signal name Explanation 4 V ext out power supply, out of external voltage, positive pole (AUX, actuator supply) 0V ext out power supply, out of external voltage, negative pole (AUX, actuator supply) I digital input L+ out power supply, out of, positive pole (IO-Link, sensor supply) 0V out power supply, out of, negative pole (IO-Link, sensor supply) I/O/Com connection optionally for input, output or IO-Link communication page 4 Mannheim, We reserve the right to change any data

5 / IO-Link Module, Connections Art. no. M Marking Function Pin Pin Pin3 Pin4 Pin5 connection assignment P P 4 V slave ext out I 0 V ext out I/O/Com nc X P P 4 V ext out I 0 V ext out I/O/Com nc BWU853 P3 P3 4 V slave ext out I3 0 V ext out I/O/Com3 nc X4 P4 P4 4 V ext out I4 0 V ext out I/O/Com4 nc (dummy plug) connection for addressing device P P L+ Slave out 4 V ext out 0V out I/O/Com 0 V ext out X P P L+ out 4 V ext out 0V out I/O/Com 0 V ext out P3 P3 L+ Slave out 4 V ext out 0V out I/O/Com3 0 V ext out X4 P4 P4 L+ out 4 V ext out 0V out I/O/Com4 0 V ext out (dummy plug) connection for addressing device X X Accessories: substructure module (CNOMO) for 8 channel module in 60 mm housing (art. no. BW35) Protection caps for unused M sockets (art. no. BW368) We reserve the right to change any data Mannheim, page 5

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports

AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12

More information

Digital Modules AS-i, IP67, M12

Digital Modules AS-i, IP67, M12 Digital Modules, IP67, M1 x connectors for color LEDs per output, state (yellow), overload (red) BWU487 / BWU547 / BWU55 / BWU594 / BWU60 / BWU713 / BWU75 / BWU78 (Figure similar) BWU617 / BWU619 / BWU66

More information

Analog Modules AS-i, IP67, M12

Analog Modules AS-i, IP67, M12 Analog Modules, M12 2 x 2 connectors for compact housing, IP67 (Figure similar) Figure Type Inputs analog Outputs analog M12 connection Input voltage (sensor supply) Output voltage (actuator supply) (2)

More information

Digital Modules AS-i in IP20, 22,5 mm

Digital Modules AS-i in IP20, 22,5 mm Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3)

More information

AS-i 3.0 motor module

AS-i 3.0 motor module 3.0 motor module 3.0 motor module for two 4 V motorized rollers Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) with 4 binary and analog outputs Mixed input/output slave Speed setting of parameter Protection category

More information

AS-i 3.0 Motor modules

AS-i 3.0 Motor modules AS-i 3.0 motor modules for two 4 V motorized rollers e.g. Interroll (EC00, EC300, EC310) or RULMECA (RDR BL-) or Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) slaves in one module 1 Single Slave with - s - digital

More information

AS-i Safety Input Modules (M12), IP67

AS-i Safety Input Modules (M12), IP67 Input Modules (), IP67 Input Modules (), IP67 for opto, floating contacts or complementary switch Applications up to category 4/PLe/SIL 3 (Figure similar) Figure Type Inputs, SIL 3, cat. 4 4 x, 4 x, 4

More information

AS-i 3.0 motor modules

AS-i 3.0 motor modules AS-i 3.0 4I/4O modules for two 4 V motorized rollers e.g. Interroll (EC00, EC300 or EC30) or RULMECA (RDR BL-) or Rollex (type 840) with binary and analog outputs Mixed input/output slave Speed setting

More information

Active Distributors AS-i Safety, Active Distributors AS-i

Active Distributors AS-i Safety, Active Distributors AS-i Active Distributors Safety, Active Distributors x connectors for Periphery connection via, M cable sockets or push in terminals (Figure similar) Figure Type Inputs Safety, SIL, Cat. x 9 mm, -channels Safety

More information

Analog Modules AS-i IP65, M12

Analog Modules AS-i IP65, M12 Plug and Play as simply as digital AS-i I/O BWU1361 / BWU1362 / BWU1722 / BWU1853 / BWU1917 / BWU1363 / BWU2532 / BWU1359 / BW1360 / BWU1893 BWU1894 BWU1895 BWU1963 BWU1964 Housing, construction: IP65,

More information

AS-i Safety Output Module, IP20

AS-i Safety Output Module, IP20 a AS-i Safety Output Module Safe outputs and standard inputs in one module Protection category IP20 Figure Housing Inputs digital Outputs Safety, SIL3, cat.4 Input voltage (sensor supply) 1 Output voltage

More information

Active Distributors ASi Safety, IP67

Active Distributors ASi Safety, IP67 x connectors for profile cable Periphery connection via M8 cable sockets M cable sockets (Figure similar) Figure Type Inputs, SIL 3, Cat. 4 9 mm 9 mm 9 mm 9 mm channels channels channels channels Inputs

More information

PCB AS-i modules, board based solutions

PCB AS-i modules, board based solutions Special variants on request (Figure similar) PCB modules, board based solutions Circuit Inputs board dimensions digital Inputs analog Outputs digital Connection Coated LED status display 4 Input voltage

More information

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input

AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20

More information

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O

AS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O ext. in ext. in Safety Output Module with Safety and standard I/O in one module Electronic safety output Additional 3 standard inputs, 1 EDM input, 2 outputs IEC 61508 SIL 3, EN ISO 13849-1 PLe Cat 4,

More information

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes

Encoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes w AS-i Speed Monitor for sine/cosine encoder for HTL encoder for SSI encoder for TTL encoder for sensors for 2 fast electronic safe outputs 128 devices Supplied out of AS-i and external 24 V (figure similar)

More information

AS-i 3.0 Sercos Gateways with integrated Safety Monitor

AS-i 3.0 Sercos Gateways with integrated Safety Monitor AS-i 3.0 Sercos Gateways with Safety on Sercos and Safe Link in one device up to 456 Devices Safely monitoring safety drives with Safety on Sercos 2 / 1 AS-i master, Sercos slave switch integrated (figure

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways 2 AS-i Masters, 1 PROFIBUS Slave Up to 32 release circuits up to 6 CAT4, SIL 3 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous Up to 32

More information

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category

More information

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor

AS-i 3.0 PROFINET-Gateways with integrated Safety Monitor AS-i 3.0 PROFI Gateways with Master, 1 PROFI Slave Up to 32 release circuits up to 6 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i outputs Multiple

More information

AS-i Safety Analog Input Module, IP20

AS-i Safety Analog Input Module, IP20 2 safe inputs in one module: 4... 20 ma or 0... 10 V or Pt100 or thermocouple (type J / K / N / R / S) Applications up to category 4/PLe/SIL 3 (figure similar) The AS-i Safety Input Module for analog inputs

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 AS-i networks Operation using a single Monitor configuration! Monitor processes safety slaves on two AS-i networks

More information

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input

AS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input ext. in ext. in AS-i Safety Relay Output Module with Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V Additionally 1 EDM input, 1 x

More information

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor AS-i 3.0 -Gateways 2 / 1 AS-i Master, -Slave (1) switch integrated Up to 64 release circuits up to circuits SIL 3, cat. 4 on the Monitor, relays or fast Safe AS-i outputs are supported up to 32 independent

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up

More information

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor

AS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor AS-i 3.0 -Gateways 2 / 1 AS-i Master, -Slave 1 switch integrated up to 32 release circuits up to 6 release circuits SIL 3, cat. 4 on the Monitor Safe AS-i outputs are supported up to 32 independent AS-i

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET safe via or AS-i 3.0 Gateways, safe via or 2 / 1 Master, / Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up to 6 CAT4, SIL 3 safe output

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous

More information

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET

AS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET via PROFI or PROF AS-i 3.0 Gateways, via PROF or PROFI 22 / 1 Master, PROF / PROFI Slave AS-i Safety input slaves report via AS-i Safety output slaves switch via Up to 32 release circuits up to 6 CAT4,

More information

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor

AS-i 3.0 EtherCAT Gateways with integrated Safety Monitor AS-i 3.0 EtherCAT Gateways with 2 / 1 Master, EtherCat Slave 1 Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous

More information

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor

AS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 Master, Slave 1 AS-i Safety Monitor for 2 AS-i networks Operation using a single Monitor configuration! Monitor processes safety slaves on two AS-i networks Coupling

More information

AS-Interface I/O Module

AS-Interface I/O Module AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard

More information

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017

Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017 Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC5274 7390889/00 07/2017 Contents 1 Functions and features...3 2 Operating and display elements...3 3 Installation...4

More information

Operating instructions. ProcessLine analogue module AC / / 2012

Operating instructions. ProcessLine analogue module AC / / 2012 Operating instructions ProcessLine analogue module AC2916 739089 / 01 06 / 2012 Contents 1 Safety instructions... 3 2 Functions and features... 4 3 Operating and display elements... 4 4 Electrical connection...

More information

Installation Instructions Temperature transmitter TAA /00 06/2011

Installation Instructions Temperature transmitter TAA /00 06/2011 Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic

More information

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no

4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics

More information

Diagnostics (Logical) Diagnostics (Physical)

Diagnostics (Logical) Diagnostics (Physical) Analog Output Stations Analog on AS-I IP 20 for In-The-Cabinet Powered by AS-I or Auxiliary Supply Voltage and Current Outputs ASI-AO-2 BW1412 ASI-AO-2A BW1727 Electrical Operating Current:

More information

VersaMax IP I/O Module

VersaMax IP I/O Module Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)

More information

Operating instructions valve control box AS-i

Operating instructions valve control box AS-i THIS LEAFLET SHOULD BE KEPT IN A SAFE PLACE FOR REFERENCE Operating instructions valve control box AS-i 1 System description The Norgren Herion valve control box is used for controlling pneumatic swivel

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)

More information

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus

EtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus EtherNet/IP Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module

More information

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C

Safety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application

More information

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. R Safety Interlock Switches MA Series MA For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Magnetically Actuated Safety

More information

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output

XPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation

More information

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB

Strain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:

More information

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA

VEO. V2UF230V10 Art.Nr.: TECHNICAL DATA Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after

More information

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet

FLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system

More information

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name

XPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018

More information

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I

STBEHC3020KC counter kit STB - 1 CH Hz - 2 I Characteristics counter kit STB - 1 CH - 0..40000 Hz - 2 I Main Range of product Product or component type Number of channels 1 Complementary Kit composition Counting input number 2 Counting frequency

More information

GS202 Encoder Switch

GS202 Encoder Switch GS202 Encoder Switch 20:2 encoder switch 20 encoder inputs (TTL / RS422 standard) Input signals A, /A, B, /B, Z, /Z on each encoder input 2 x 6 control inputs (HTL / PNP) 2 encoder outputs (TTL / RS422

More information

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015

Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015 Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC5294 80226775/00 02/2015 Contents 1 Preliminary note...3 2 Safety instructions...3 3 Functions

More information

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus

4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus 4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,

More information

Protected VARAN Digital Mixed Module PVDM 086

Protected VARAN Digital Mixed Module PVDM 086 PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Protected VARAN Digital Mixed Module PVDM 086 The PVDM 086 Protected VARAN Digital Mixed Module has eight +24 V/2 A digital outputs (positive switching) that

More information

Device manual AS-i PowerSwitch ZB0028 ZB0040

Device manual AS-i PowerSwitch ZB0028 ZB0040 Device manual AS-i PowerSwitch ZB0028 ZB0040 System AS-i Page 1 of 16 Device manual POWERSWITCH ZB0028 ZB0040 Date: 04/02/02 Contents 1. Views... 3 1.1 Top view... 3 1.2 Front view... 4 1.3 Bottom view...

More information

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide

BNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide BNI IOL302000Z013 BNI IOL302S01Z013 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ013 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax

More information

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide

BNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ026 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions

More information

Inductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3-wire, plastic housing

Inductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3-wire, plastic housing Inductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3wire, plastic housing Dimensions in mm 121 PG 13,5 101 27 Features Can be installed flush or nonflush in metal Variable switching

More information

BNI IOL-104-S01-Z012-C02

BNI IOL-104-S01-Z012-C02 BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical

More information

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2

Programmable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2 Type designation Ident no. 1545069 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100

More information

Diagnostics (Logical)

Diagnostics (Logical) Input Station Rugged, Fully Potted Stations IP 67 Protection Flat and Round Cable Support AS-I Version 2.1 FAS4-S0400 Electrical Operating Current:

More information

Sensor boxes SRBG Key features

Sensor boxes SRBG Key features Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn

More information

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection 4.8 Digital Input/Output Module 07 DC 9 3 configurable digital inputs/outputs, 4 V DC, electrically isolated in groups, outputs can be loaded with 500 ma, CS31 system bus 1 3 4 1 Fig. 4.8-1: Digital input/output

More information

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2

Programmable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2 Type designation Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100

More information

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45

AS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45 Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages

More information

Faults on the system Proximity switch connection technology:

Faults on the system Proximity switch connection technology: Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches

More information

Operating instructions AC010S Compact AS-i E-STOP safety module

Operating instructions AC010S Compact AS-i E-STOP safety module Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................

More information

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA

VEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status

More information

TM221ME32TK controller M IO transistor PNP Ethernet

TM221ME32TK controller M IO transistor PNP Ethernet Product data sheet Characteristics TM221ME32TK controller M221 32 IO transistor PNP Ethernet Complementary Main Discrete I/O number 32 Number of I/O expansion module Supply voltage limits Inrush current

More information

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number

EPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage

More information

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:

DIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features: DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:

More information

Operating instructions Memory plug E /02 11/2011

Operating instructions Memory plug E /02 11/2011 Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

TABLE OF CONTENTS AS-INTERFACE

TABLE OF CONTENTS AS-INTERFACE TABLE OF CONTENTS AS-Interface module AAAA...2 AS-Interface module EEAA...4 AS-Interface module EEEE...6 AS-Interface coupler module PGK...8 AS-Interface coupler module FKK...10 AS-Interface coupler module

More information

SITOP in the SIMATIC Design

SITOP in the SIMATIC Design Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT

More information

Technical Description

Technical Description B Content 1. Allgemeines...1 2. Blockdiagramm...2 3. Inbetriebnahme...2 4. Technische Daten...3 4.1 AS-Interface...3 4.2 Anschlussbelegung...3 4.3 LED Anzeige...4 4.4 Mechanische und Umgebungsdaten...4

More information

AS-interface modules CESA

AS-interface modules CESA Key features Basic principles and features of the bus system Introduction The AS-interface system permits the transfer of power and data using a single cable. The advanced technology used to connect stations

More information

MobileView Junction Box

MobileView Junction Box Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard

More information

AS-i Safety Relay Output Module with Diagnostic Slave

AS-i Safety Relay Output Module with Diagnostic Slave AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3 Subject to modifications without notice. Generally, this

More information

IT power distribution Power distribution units (PDU) Basic. Versions available:

IT power distribution Power distribution units (PDU) Basic. Versions available: IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,

More information

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions RFID evaluation unit DTE / / 2016 Operating instructions RFID evaluation unit DTE101 80005398 / 01 06 / 2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety instructions...4 2.1 General...4

More information

Compact Coded Magnetic Safety Interlock Switch and Control Units

Compact Coded Magnetic Safety Interlock Switch and Control Units C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch

More information

RSTI-EP Slice I/O. Digital Output Module

RSTI-EP Slice I/O. Digital Output Module GFK-2959B December 2015 RSTI-EP Slice I/O Digital Output Modules EP-2214, EP-2614, EP-2634, EP-2218, EP-225F Relay Output Module Solid-state Relay Output Module EP-2814 Module Status LED Channel Status

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

TM221CE24R controller M IO relay Ethernet

TM221CE24R controller M IO relay Ethernet Product data sheet Characteristics TM221CE24R controller M221 24 IO relay Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Inrush

More information

GFK-2415A March Type of sensor connection

GFK-2415A March Type of sensor connection VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by

More information

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system

The SMART Non-contact Safety Sensor SRF With an innovative diagnostic system The SMART With an innovative diagnostic system Actual size shown Very compact: small in size, flexible in use Very Smart: suitable for Industry 4.0 with its intelligent diagnostic system Cost Saving: four-wire

More information

Datasheet AZM 161 Z ST1 AS RA

Datasheet AZM 161 Z ST1 AS RA 25.10.2016 10:35:58h Datasheet AZM 161 Z ST1 AS RA AS interface safety at work / Safety switchgear / Solenoid interlock / AZM 161 AS Preferred typ Solenoid interlock Thermoplastic enclosure High holding

More information

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6

Profibus-DPV1 Set in IP67 TI-BL67-DPV1-6 Type designation Ident no. 1545030 Number of channels 6 Dimensions (W x L x H) 172 x 145 x 77.5 mm Cable max. 50 m between interface and read/write head 3 decimal rotary coding switches for the adjustment

More information

INTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual

INTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual INTEGRUS DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM Installation and Operating Manual LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker LBB 3422/10 Symmetrical Audio Input and Interpreters Module

More information

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.

Control elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h. On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status

More information

Multiturn absolute encoder

Multiturn absolute encoder Release date: 207-0-2 :0 Date of issue: 207-0-2 t79_eng.xml Model Number Features Industrial standard housing Ø58 mm PROFINET IRT 0 Bit multiturn Servo or clamping flange Network loop through by means

More information

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink

General. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the

More information