AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
|
|
- Dominick Fisher
- 5 years ago
- Views:
Transcription
1 / IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master single in one housing Power supply of s out of AUX (or ) Figure Type Inputs digital 8x M 8x M 4 x + 4 x + Outputs digital 4x 4x 8x M 4 x 4x M wiring class A class A Class B Input voltage (sensor supply) out of AUX out of out of Output voltage (actuator supply) out of AUX out of out of connection 3 address 4 single single single Max. output current Art. no. 500 ma BWU853 0 ma BWU ma Input voltage (sensor supply) Inputs are supplied by or by AUX (auxiliary 4 V power). If supplied by, inputs can neither be connected to earth nor to external potential. Output voltage (actuator supply) The supply of the outputs is made by or by AUX (auxiliary 4 V power). By supply out of there is no connection to earth or external potential allowed. 3 connection The connection to as well to AUX (auxiliary 4 V power) is made via yellow or black with piercing technology or via M socket (in IP0 via clamps). 4 address AB slave (max. 6 AB / network), AB (max. 3 modules with AB ), single (max. 3 single / network), mixed use allowed (upon request, are available with specific AS-slave profiles). 5 Only on request. We reserve the right to change any data Mannheim, page
2 / IO-Link Module, Article no. BWU853 Connection /AUX connection and piercing Periphery connection M Length of connector cable I/O: max. 0 m IO-Link Number 4 ports Data rate COM / COM / COM3 IO-Link revision. Profile slave : S (ID=F default) slave : S (ID=E default) Address single Operating voltage 30 V (8 3.6 V) 30 V (4 3.6 V) Required master profile M4 Since specification 3.0 Max. current consumption 50 ma 00 ma Max. current consumption without 50 ma 80 ma sensor / actuator supply AUX Voltage 4 V (8 30 V) Max. current consumption 4 A Input Number 4 (via ) + 4 (via ) Power supply out of AUX out of Supply of attached sensors 500mA per port, (sensors + outputs) max. A (sensors + outputs) max. 0 ma 3 Switching threshold U<5 V (low) U>5 V (high) Output Number 4 (via ) Power supply out of AUX out of Max. output current 500 ma per port, (sensors + outputs) max. A (sensors + outputs) max. 0 ma 3 Display LED ASI (green) LED FLT/FAULT (red) LED AUX (red/green) LEDs P... Pn (red/green) on: no data exchange flashing: AUX voltage missing, overload sensor supply, overload output or IO-Link error on: voltage on off: no voltage green: AUX voltage OK red: AUX voltage < 8 V state of P... P4 green: IO-Link communication OK yellow: switching signal at input or output red: IO-Link communication error on: no data exchange flashing: overload sensor supply, overload output or IO-Link error page Mannheim, We reserve the right to change any data
3 / IO-Link Module, Article no. BWU853 Environment Applied standards EN EN EN 6 3- Operating temperature Storage temperature Housing plastic, for DIN rail mounting Protection cat. (EN 6059) Max. tolerable shock and vibration stress Isolation voltage 5 g, T ms Hz, 0,5 mm amplitude 500 V Dimensions (W / H / D in mm) 60 / 5 / 3 Weight 00 g Derating total current out of AUX I Σ (AUX) A BWU853 Derating total current per port I Port max. A 0, We reserve the right to change any data Mannheim, page 3
4 / IO-Link Module, 3 Derating total current out of I Σ (Sensors and outputs) ma Programming bit assignment Bit D0 D D D3 Input BWU853 / Slave : P-I Slave : P-I Slave : P3-I Slave : P4-I Output BWU853 / adjustable adjustable BWU853 / Parameter bit P0 P P 0=data mapping 0= IO-Link parameter 0= manual setting of adjustable backup active port configuration = default data mapping activated = no IO-Link parameter backup Via process data mapping and IO-Link gateway configuration adjustable. Plug and Communication mode is not usable with digital outputs (actuator without IO-Link). Digital inputs are frozen during IO-Link wakeup sequence. = plug and comm mode active Pin assignment Signal name Explanation 4 V ext out power supply, out of external voltage, positive pole (AUX, actuator supply) 0V ext out power supply, out of external voltage, negative pole (AUX, actuator supply) I digital input L+ out power supply, out of, positive pole (IO-Link, sensor supply) 0V out power supply, out of, negative pole (IO-Link, sensor supply) I/O/Com connection optionally for input, output or IO-Link communication page 4 Mannheim, We reserve the right to change any data
5 / IO-Link Module, Connections Art. no. M Marking Function Pin Pin Pin3 Pin4 Pin5 connection assignment P P 4 V slave ext out I 0 V ext out I/O/Com nc X P P 4 V ext out I 0 V ext out I/O/Com nc BWU853 P3 P3 4 V slave ext out I3 0 V ext out I/O/Com3 nc X4 P4 P4 4 V ext out I4 0 V ext out I/O/Com4 nc (dummy plug) connection for addressing device P P L+ Slave out 4 V ext out 0V out I/O/Com 0 V ext out X P P L+ out 4 V ext out 0V out I/O/Com 0 V ext out P3 P3 L+ Slave out 4 V ext out 0V out I/O/Com3 0 V ext out X4 P4 P4 L+ out 4 V ext out 0V out I/O/Com4 0 V ext out (dummy plug) connection for addressing device X X Accessories: substructure module (CNOMO) for 8 channel module in 60 mm housing (art. no. BW35) Protection caps for unused M sockets (art. no. BW368) We reserve the right to change any data Mannheim, page 5
AS-i / IO-Link Module, IO-Link Master with 4 IO-Link Ports
/ IO-Link Module, /IO-Link Module, IO-Link Master with 4 s fourfold IO-Link Master in one housing Power supply of s (or ) (Figure similar) Figure Type Inputs digital 4 x + 4 x + 4 x Outputs digital M12
More informationDigital Modules AS-i, IP67, M12
Digital Modules, IP67, M1 x connectors for color LEDs per output, state (yellow), overload (red) BWU487 / BWU547 / BWU55 / BWU594 / BWU60 / BWU713 / BWU75 / BWU78 (Figure similar) BWU617 / BWU619 / BWU66
More informationAnalog Modules AS-i, IP67, M12
Analog Modules, M12 2 x 2 connectors for compact housing, IP67 (Figure similar) Figure Type Inputs analog Outputs analog M12 connection Input voltage (sensor supply) Output voltage (actuator supply) (2)
More informationDigital Modules AS-i in IP20, 22,5 mm
Digital Modules AS-i in 22,5 mm Cost efficient solution in IP20 (Figure similar) Figure Type Housing s digital digital voltage (sensor supply) (1) Output voltage (actuator supply) (2) AS-i connection (3)
More informationAS-i 3.0 motor module
3.0 motor module 3.0 motor module for two 4 V motorized rollers Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) with 4 binary and analog outputs Mixed input/output slave Speed setting of parameter Protection category
More informationAS-i 3.0 Motor modules
AS-i 3.0 motor modules for two 4 V motorized rollers e.g. Interroll (EC00, EC300, EC310) or RULMECA (RDR BL-) or Itoh Denki (PM00ME/XE/XP, PM60ME/XE/XP) slaves in one module 1 Single Slave with - s - digital
More informationAS-i Safety Input Modules (M12), IP67
Input Modules (), IP67 Input Modules (), IP67 for opto, floating contacts or complementary switch Applications up to category 4/PLe/SIL 3 (Figure similar) Figure Type Inputs, SIL 3, cat. 4 4 x, 4 x, 4
More informationAS-i 3.0 motor modules
AS-i 3.0 4I/4O modules for two 4 V motorized rollers e.g. Interroll (EC00, EC300 or EC30) or RULMECA (RDR BL-) or Rollex (type 840) with binary and analog outputs Mixed input/output slave Speed setting
More informationActive Distributors AS-i Safety, Active Distributors AS-i
Active Distributors Safety, Active Distributors x connectors for Periphery connection via, M cable sockets or push in terminals (Figure similar) Figure Type Inputs Safety, SIL, Cat. x 9 mm, -channels Safety
More informationAnalog Modules AS-i IP65, M12
Plug and Play as simply as digital AS-i I/O BWU1361 / BWU1362 / BWU1722 / BWU1853 / BWU1917 / BWU1363 / BWU2532 / BWU1359 / BW1360 / BWU1893 BWU1894 BWU1895 BWU1963 BWU1964 Housing, construction: IP65,
More informationAS-i Safety Output Module, IP20
a AS-i Safety Output Module Safe outputs and standard inputs in one module Protection category IP20 Figure Housing Inputs digital Outputs Safety, SIL3, cat.4 Input voltage (sensor supply) 1 Output voltage
More informationActive Distributors ASi Safety, IP67
x connectors for profile cable Periphery connection via M8 cable sockets M cable sockets (Figure similar) Figure Type Inputs, SIL 3, Cat. 4 9 mm 9 mm 9 mm 9 mm channels channels channels channels Inputs
More informationPCB AS-i modules, board based solutions
Special variants on request (Figure similar) PCB modules, board based solutions Circuit Inputs board dimensions digital Inputs analog Outputs digital Connection Coated LED status display 4 Input voltage
More informationAS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input
Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20
More informationAS-i Safety Output Module with Diagnostic Slave, 1 EDM input, 3I and 2O
ext. in ext. in Safety Output Module with Safety and standard I/O in one module Electronic safety output Additional 3 standard inputs, 1 EDM input, 2 outputs IEC 61508 SIL 3, EN ISO 13849-1 PLe Cat 4,
More informationEncoder signal/ Sensor signal. Number of monitored axes. sine/cosine, SSI, TTL (1) up to 2 independent axes. sine/cosine. up to 2 independent axes
w AS-i Speed Monitor for sine/cosine encoder for HTL encoder for SSI encoder for TTL encoder for sensors for 2 fast electronic safe outputs 128 devices Supplied out of AS-i and external 24 V (figure similar)
More informationAS-i 3.0 Sercos Gateways with integrated Safety Monitor
AS-i 3.0 Sercos Gateways with Safety on Sercos and Safe Link in one device up to 456 Devices Safely monitoring safety drives with Safety on Sercos 2 / 1 AS-i master, Sercos slave switch integrated (figure
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways 2 AS-i Masters, 1 PROFIBUS Slave Up to 32 release circuits up to 6 CAT4, SIL 3 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous Up to 32
More informationArticle no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC
Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category
More informationAS-i 3.0 PROFINET-Gateways with integrated Safety Monitor
AS-i 3.0 PROFI Gateways with Master, 1 PROFI Slave Up to 32 release circuits up to 6 safe output circuits on the Monitor safe relays or fast electronic safe outputs up to 32 independent AS-i outputs Multiple
More informationAS-i Safety Analog Input Module, IP20
2 safe inputs in one module: 4... 20 ma or 0... 10 V or Pt100 or thermocouple (type J / K / N / R / S) Applications up to category 4/PLe/SIL 3 (figure similar) The AS-i Safety Input Module for analog inputs
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 AS-i networks Operation using a single Monitor configuration! Monitor processes safety slaves on two AS-i networks
More informationAS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input
ext. in ext. in AS-i Safety Relay Output Module with Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V Additionally 1 EDM input, 1 x
More informationAS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor
AS-i 3.0 -Gateways 2 / 1 AS-i Master, -Slave (1) switch integrated Up to 64 release circuits up to circuits SIL 3, cat. 4 on the Monitor, relays or fast Safe AS-i outputs are supported up to 32 independent
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS safe and Safe Link in one device up to 450 devices 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via BUS or NET AS-i 3.0 Gateways, safe via NET or BUS 2 / 1 Master, NET / BUS Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up
More informationAS-i 3.0 EtherNet/IP + Modbus TCP-Gateways with integrated Safety Monitor
AS-i 3.0 -Gateways 2 / 1 AS-i Master, -Slave 1 switch integrated up to 32 release circuits up to 6 release circuits SIL 3, cat. 4 on the Monitor Safe AS-i outputs are supported up to 32 independent AS-i
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
safe via or AS-i 3.0 Gateways, safe via or 2 / 1 Master, / Slave AS-i Safety input slaves report via safe AS-i Safety output slaves switch via safe Up to 32 release circuits up to 6 CAT4, SIL 3 safe output
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 AS-i Master, Slave 1 AS-i Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous
More informationAS-i 3.0 Gateways, PROFIsafe via PROFIBUS or PROFINET
via PROFI or PROF AS-i 3.0 Gateways, via PROF or PROFI 22 / 1 Master, PROF / PROFI Slave AS-i Safety input slaves report via AS-i Safety output slaves switch via Up to 32 release circuits up to 6 CAT4,
More informationAS-i 3.0 EtherCAT Gateways with integrated Safety Monitor
AS-i 3.0 EtherCAT Gateways with 2 / 1 Master, EtherCat Slave 1 Safety Monitor for 2 s Operation using a single Monitor! Monitor processes safety slaves on two s Coupling between the two networks superfluous
More informationAS-i 3.0 PROFIBUS Gateways with integrated Safety Monitor
AS-i 3.0 Gateways AS-i 3.0 Gateways 2 / 1 Master, Slave 1 AS-i Safety Monitor for 2 AS-i networks Operation using a single Monitor configuration! Monitor processes safety slaves on two AS-i networks Coupling
More informationAS-Interface I/O Module
AS-Interface I/O Module Construction The AS-Interface I/O module is designed as a compact, robust field module. It is composed of an electronic module (top) and a coupler module (base). Connectors (standard
More informationOperating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017
Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC5274 7390889/00 07/2017 Contents 1 Functions and features...3 2 Operating and display elements...3 3 Installation...4
More informationOperating instructions. ProcessLine analogue module AC / / 2012
Operating instructions ProcessLine analogue module AC2916 739089 / 01 06 / 2012 Contents 1 Safety instructions... 3 2 Functions and features... 4 3 Operating and display elements... 4 4 Electrical connection...
More informationInstallation Instructions Temperature transmitter TAA /00 06/2011
Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident-No
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics
More informationMagnetically Actuated Safety Interlock Switches
Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic
More information4 non-safe digital I/O channels 2 IO-Link Master V1.1 slots. Figure 1. Figure 2. Type designation. TBPN-L1-FDIO1-2IOL Ident no
PROFINET slave Integrated Ethernet switch 100 Mbps supported 2 x M12, 4-pin, D-coded, Ethernet fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module electronics
More informationDiagnostics (Logical) Diagnostics (Physical)
Analog Output Stations Analog on AS-I IP 20 for In-The-Cabinet Powered by AS-I or Auxiliary Supply Voltage and Current Outputs ASI-AO-2 BW1412 ASI-AO-2A BW1727 Electrical Operating Current:
More informationVersaMax IP I/O Module
Module accepts four digital input signals and provides four digital outputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by a Profibus Interface Unit (IC677PBI001)
More informationOperating instructions valve control box AS-i
THIS LEAFLET SHOULD BE KEPT IN A SAFE PLACE FOR REFERENCE Operating instructions valve control box AS-i 1 System description The Norgren Herion valve control box is used for controlling pneumatic swivel
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-1A8 Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB GSV-1A8USB SubD1 (front side) GSV-1A8USB M12 (front side) GSV-1A16USB (rear side) GSV-1A8USB K6D (front side)
More informationEtherNet/IP. Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus
EtherNet/IP Integrated Ethernet switch 10 Mbps / 100 Mbps supported 2 x male M12, 4-pin, D-coded, Ethernet-Fieldbus connection Glass fiber reinforced housing Shock and vibration tested Fully potted module
More informationSafety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C
r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches MA Series MA For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Magnetically Actuated Safety
More informationXPSMF40. Main. Safety module name. Monitoring safety detection discrete input Monitoring safety dialogue discrete output
Product datasheet Characteristics XPSMF4000 Preventa safety PLC compact - Safe Ethernet Main Range of product Product or component type Safety module name Safety module application Preventa Safety automation
More informationStrain gauge Measuring Amplifier GSV-1A8. Instruction manual GSV-1A8, GSV-1A8USB, GSV-1A16USB
Strain gauge Measuring Amplifier GSV-A8 Instruction manual GSV-A8, GSV-A8USB, GSV-A6USB GSV-A8USB SubD5 (front side) GSV-A8USB M2 (front side) GSV-A6USB (rear side) GSV-A8USB K6D (front side) Version:
More informationVEO. V2UF230V10 Art.Nr.: TECHNICAL DATA
Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after
More informationFLM DI 8 M12. Function. Fieldline Modular Device With Eight Digital Inputs. Data Sheet
Fieldline Modular Device With Eight Digital Inputs Data Sheet 697000 02/2004 This data sheet is only valid in association with the FLS FLM SYS INST UM E user manual or the user manual for your bus system
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationSTBEHC3020KC counter kit STB - 1 CH Hz - 2 I
Characteristics counter kit STB - 1 CH - 0..40000 Hz - 2 I Main Range of product Product or component type Number of channels 1 Complementary Kit composition Counting input number 2 Counting frequency
More informationGS202 Encoder Switch
GS202 Encoder Switch 20:2 encoder switch 20 encoder inputs (TTL / RS422 standard) Input signals A, /A, B, /B, Z, /Z on each encoder input 2 x 6 control inputs (HTL / PNP) 2 encoder outputs (TTL / RS422
More informationOperating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015
Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC5294 80226775/00 02/2015 Contents 1 Preliminary note...3 2 Safety instructions...3 3 Functions
More information4.7 Digital Input/Output Module 07 DC digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 24 V DC, CS31 system bus
4.7 Digital Input/Output Module 16 digital inputs, 8 digital outputs, 8 configurable inputs/outputs, 4 V DC, CS31 system bus 1 3 Advant Controller 31 I/O Unit ERR Test 4 1 Fig. 4.7-1: Digital input/output
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationProtected VARAN Digital Mixed Module PVDM 086
PROTECTED VARAN DIGITAL MXED MODULE PVDM 086 Protected VARAN Digital Mixed Module PVDM 086 The PVDM 086 Protected VARAN Digital Mixed Module has eight +24 V/2 A digital outputs (positive switching) that
More informationDevice manual AS-i PowerSwitch ZB0028 ZB0040
Device manual AS-i PowerSwitch ZB0028 ZB0040 System AS-i Page 1 of 16 Device manual POWERSWITCH ZB0028 ZB0040 Date: 04/02/02 Contents 1. Views... 3 1.1 Top view... 3 1.2 Front view... 4 1.3 Bottom view...
More informationBNI IOL Z013 BNI IOL-302-S01-Z013. User s Guide
BNI IOL302000Z013 BNI IOL302S01Z013 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ013 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions
More informationBNI IOL Z026 BNI IOL-302-S01-Z026 User s Guide
BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions 2 1.3.1 Enumerations 2 1.3.2 Actions 2 1.3.3 Syntax
More informationBNI IOL Z026 BNI IOL-302-S01-Z026. User s Guide
BNI IOL302000Z026 BNI IOL302S01Z026 User s Guide Balluff Network Interface / IOLink BNI IOL302xxxZ026 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical conventions
More informationInductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3-wire, plastic housing
Inductive proximity sensors IQ 40 series, sensing range 15 / 20 mm DC 3wire, plastic housing Dimensions in mm 121 PG 13,5 101 27 Features Can be installed flush or nonflush in metal Variable switching
More informationBNI IOL-104-S01-Z012-C02
BNI IOL104S01Z012C01 BNI IOL104S01Z012C02 BNI IOL302S01Z013C01 User s Guide Balluff Network Interface / IOLink 1 Notes for the user 1.1 About this guide 2 1.2 Structure of the guide 2 1.3 Typographical
More informationProgrammable Set for Ethenet/IP in IP67 TI-BL67-PG-EIP-2
Type designation Ident no. 1545069 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100
More informationDiagnostics (Logical)
Input Station Rugged, Fully Potted Stations IP 67 Protection Flat and Round Cable Support AS-I Version 2.1 FAS4-S0400 Electrical Operating Current:
More informationSensor boxes SRBG Key features
Key features Function SRBG sensor boxes are the compact solution when it comes to electrical feedback signals and monitoring the position of process valves which are actuated with pneumatic quarter turn
More information4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection
4.8 Digital Input/Output Module 07 DC 9 3 configurable digital inputs/outputs, 4 V DC, electrically isolated in groups, outputs can be loaded with 500 ma, CS31 system bus 1 3 4 1 Fig. 4.8-1: Digital input/output
More informationProgrammable Set for Ethernet Modbus/TCP in IP67 TI-BL67-PG-EN-2
Type designation Ident no. 1545065 Number of channels 2 Dimensions (W x L x H) 108 x 145 x 77.5 mm CoDeSys-programmable acc. to IEC 61131-3 Cable max. 50 m between interface and read/write head 10/100
More informationAS-Interface Slaves. I/O Modules for Operation in the Field. Digital I/O modules IP67 - K45
Overview The large industry-proven K60 compact modules are complemented perfectly by the K45 compact module series. They round off the existing product range of smaller modules. The acknowledged advantages
More informationFaults on the system Proximity switch connection technology:
Speed monitor for connection to a base unit from the PNOZmulti modular safety system Approvals Unit features Monitoring of 2 independent axes Connection of 2 incremental encoders or 4 proximity switches
More informationOperating instructions AC010S Compact AS-i E-STOP safety module
Operating instructions AC010S Compact AS-i E-STOP safety module Sachnr. 7390636_/00 05/2007 Contents Safety instructions............................. 3 Installation / Setup............................
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationTM221ME32TK controller M IO transistor PNP Ethernet
Product data sheet Characteristics TM221ME32TK controller M221 32 IO transistor PNP Ethernet Complementary Main Discrete I/O number 32 Number of I/O expansion module Supply voltage limits Inrush current
More informationEPGG001. Fieldbus Gateway RS-232 to PROFINET. Industrial Communication. Technical Data. Part Number
Fieldbus Gateway RS-232 to PROFINET EPGG001 Part Number Easy handling Gateway from RS-232/422/485 interfaces to PROFINET With two Industrial Ethernet ports Technical Data Electrical Data Supply Voltage
More informationDIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:
DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:
More informationOperating instructions Memory plug E /02 11/2011
Operating instructions Memory plug E30398 UK 704930/02 11/2011 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Terms used...3 2 Safety instructions...4 3 Factory setting...4 4 Functions and features...5
More informationExpansion Module HZS 541-1S
Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs
More informationTABLE OF CONTENTS AS-INTERFACE
TABLE OF CONTENTS AS-Interface module AAAA...2 AS-Interface module EEAA...4 AS-Interface module EEEE...6 AS-Interface coupler module PGK...8 AS-Interface coupler module FKK...10 AS-Interface coupler module
More informationSITOP in the SIMATIC Design
Siemens AG 2017 /2 Introduction /3 1-phase, 24 V DC (for S7-300 and ET 200M) /9 1-phase, 24 V DC (for S7-1200) /11 1-phase, 24 V DC (for S7-1500 and ET 200MP) /14 3-phase, 24 V DC (ET 200pro) Siemens KT
More informationTechnical Description
B Content 1. Allgemeines...1 2. Blockdiagramm...2 3. Inbetriebnahme...2 4. Technische Daten...3 4.1 AS-Interface...3 4.2 Anschlussbelegung...3 4.3 LED Anzeige...4 4.4 Mechanische und Umgebungsdaten...4
More informationAS-interface modules CESA
Key features Basic principles and features of the bus system Introduction The AS-interface system permits the transfer of power and data using a single cable. The advanced technology used to connect stations
More informationMobileView Junction Box
Installation Instructions MobileView Junction Box (Catalog Number 2727-MRJB2) English The MobileView Junction Box (2727-MRJB2) integrates the following terminals into the control system: MobileView Guard
More informationAS-i Safety Relay Output Module with Diagnostic Slave
AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3 Subject to modifications without notice. Generally, this
More informationIT power distribution Power distribution units (PDU) Basic. Versions available:
IT PDU Basic 1 U With its IT PDU Basic 1 U, BACHMANN provides a huge choice of PDUs in a high-quality aluminium profile. With their extremely compact size of just 1 height unit, mm in depth and 1" in width,
More informationOperating instructions RFID evaluation unit DTE / / 2016
Operating instructions RFID evaluation unit DTE101 80005398 / 01 06 / 2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety instructions...4 2.1 General...4
More informationCompact Coded Magnetic Safety Interlock Switch and Control Units
C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch
More informationRSTI-EP Slice I/O. Digital Output Module
GFK-2959B December 2015 RSTI-EP Slice I/O Digital Output Modules EP-2214, EP-2614, EP-2634, EP-2218, EP-225F Relay Output Module Solid-state Relay Output Module EP-2814 Module Status LED Channel Status
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationTM221CE24R controller M IO relay Ethernet
Product data sheet Characteristics TM221CE24R controller M221 24 IO relay Ethernet Complementary Main Discrete I/O number 24 Number of I/O expansion module Supply voltage limits Network frequency Inrush
More informationGFK-2415A March Type of sensor connection
VersaMax IP Expansion Module has four analog differential inputs that can be configured as current or voltage inputs. It connects to a local bus that is interfaced to a Profibus-DP / PROFINET network by
More informationThe SMART Non-contact Safety Sensor SRF With an innovative diagnostic system
The SMART With an innovative diagnostic system Actual size shown Very compact: small in size, flexible in use Very Smart: suitable for Industry 4.0 with its intelligent diagnostic system Cost Saving: four-wire
More informationDatasheet AZM 161 Z ST1 AS RA
25.10.2016 10:35:58h Datasheet AZM 161 Z ST1 AS RA AS interface safety at work / Safety switchgear / Solenoid interlock / AZM 161 AS Preferred typ Solenoid interlock Thermoplastic enclosure High holding
More informationProfibus-DPV1 Set in IP67 TI-BL67-DPV1-6
Type designation Ident no. 1545030 Number of channels 6 Dimensions (W x L x H) 172 x 145 x 77.5 mm Cable max. 50 m between interface and read/write head 3 decimal rotary coding switches for the adjustment
More informationINTEGRUS BOSCH DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM. Installation and Operating Manual
INTEGRUS DIGITAL INFRA-RED LANGUAGE DISTRIBUTION SYSTEM Installation and Operating Manual LBB 3222/04 6-Channel Interpreter Desk with Loudspeaker LBB 3422/10 Symmetrical Audio Input and Interpreters Module
More informationControl elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.
On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationMultiturn absolute encoder
Release date: 207-0-2 :0 Date of issue: 207-0-2 t79_eng.xml Model Number Features Industrial standard housing Ø58 mm PROFINET IRT 0 Bit multiturn Servo or clamping flange Network loop through by means
More informationGeneral. 5 and 8 port Fast Ethernet switches. 6 and 8 Port Gigabit Ethernet switches. Switches with fiber uplink
Entry Line Industrial Gigabit Ethernet Switch 4x 10/100/1000Base-T with PoE+, 1x 10/100/1000Base-T or 100/1000Base-X Combo Port, 1x 100/1000Base X SFP Slot General The IP protocol has already left the
More information