1 Direct Co-Calibration of Endobronchial Ultrasound and Video Philipp Dressel 1, Marco Feuerstein 1,2, Tobias Reichl 1,2, Takayuki Kitasaka 3, Nassir Navab 1, Kensaku Mori 2,4 1 Computer Aided Medical Procedures (CAMP), Technische Universität München, Germany 2 Graduate School of Information Science,, Japan 3 Faculty of Information Science, Aichi Institute of Technology, Japan 4 Information and Communications Headquarters,, Japan
2 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München 2 Introduction Endobronchial ultrasound (EBUS) Navigation solutions may require US/Cam calibration
3 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München 3 Ultrasound plane Camera coordinates Bronchoscope head Ultrasound coordinates Camera frustum
4 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München 4 Camera Fibreoptic Low resolution High distortion Introduction CAM H US Ultrasound Surface contact Low imaging depth Noise?
5 Method 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München v u US CAM s v s u H K y x ), ( ), ( ), ( u s v s v u K y x Image scaling Camera image coordinates Camera matrix Ultrasound image coordinates Ultrasound scaling
6 Method Measure phantom in advance Allows calibration from single image pair Estimate camera pose using method of Wengert (also considering distortion and adjusting for velocity in water with refractive index 1.33) Estimate ultrasound pose using Z-fiducial method Combine series of images for increased accuracy 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München v u US P P CAM s v s u H H K y x
7 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München 7 Method: Z-fiducials C A N Z M D B Method: [Hsu, P., Prager, R., Gee, A., Treece, G.: Real-time freehand 3D ultrasound calibration. Ultrasound in Medicine & Biology 34(2) (2008) ]
8 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München 8 Phantom
9 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München 9 Results Use tool tip to mark corresponding locations Move until tip is visible in ultrasound
10 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München 10 Results Sample point locations Compute cumulative pixel distance of point pairs Proposed method Hand-eye & single-wall + *... Camera point Ultrasound point US plane thickness Correspondences
11 cumulative pixel error cumulative pixel error 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München 11 Results Hand-eye & single-wall Proposed method n i i cpe p y qy i measurement measurement cpe n i1 i p y q i y
12 9/20/2010 Philipp Dressel, Computer Aided Medical Procedures, Technische Universität München 12 Conclusion Compared to hand-eye and single-wall: Comparable accuracy Higher precision Faster Build more complex phantom once Calibrate quickly many times
A New Approach to Ultrasound Guided Radio-Frequency Needle Placement
A New Approach to Ultrasound Guided Radio-Frequency Needle Placement Claudio Alcérreca 1,2, Jakob Vogel 2, Marco Feuerstein 2, and Nassir Navab 2 1 Image Analysis and Visualization Lab., CCADET UNAM, 04510
More informationAn Application Driven Comparison of Several Feature Extraction Algorithms in Bronchoscope Tracking During Navigated Bronchoscopy
An Application Driven Comparison of Several Feature Extraction Algorithms in Bronchoscope Tracking During Navigated Bronchoscopy Xióngbiāo Luó 1, Marco Feuerstein 1,2, Tobias Reichl 2, Takayuki Kitasaka
More informationModified Hybrid Bronchoscope Tracking Based on Sequential Monte Carlo Sampler: Dynamic Phantom Validation
Modified Hybrid Bronchoscope Tracking Based on Sequential Monte Carlo Sampler: Dynamic Phantom Validation Xióngbiāo Luó 1, Tobias Reichl 2, Marco Feuerstein 2, Takayuki Kitasaka 3, and Kensaku Mori 4,1
More informationSingle Camera Calibration
Single Camera Calibration using Partially Visible Calibration Objects Based on Random Dots Marker Tracking Algorithm *Yuji Oyamada1,2, Pascal Fallavollita2, and Nassir Navab2 1. Keio University, Japan
More informationImage Thickness Correction for Navigation with 3D Intra-cardiac Ultrasound Catheter
Image Thickness Correction for Navigation with 3D Intra-cardiac Ultrasound Catheter Hua Zhong 1, Takeo Kanade 1,andDavidSchwartzman 2 1 Computer Science Department, Carnegie Mellon University, USA 2 University
More informationTowards an Estimation of Acoustic Impedance from Multiple Ultrasound Images
Towards an Estimation of Acoustic Impedance from Multiple Ultrasound Images Christian Wachinger 1, Ramtin Shams 2, Nassir Navab 1 1 Computer Aided Medical Procedures (CAMP), Technische Universität München
More informationRigid Body Motion and Image Formation. Jana Kosecka, CS 482
Rigid Body Motion and Image Formation Jana Kosecka, CS 482 A free vector is defined by a pair of points : Coordinates of the vector : 1 3D Rotation of Points Euler angles Rotation Matrices in 3D 3 by 3
More informationGPU Ultrasound Simulation and Volume Reconstruction
GPU Ultrasound Simulation and Volume Reconstruction Athanasios Karamalis 1,2 Supervisor: Nassir Navab1 Advisor: Oliver Kutter1, Wolfgang Wein2 1Computer Aided Medical Procedures (CAMP), Technische Universität
More informationA hybrid opto-inertial Tracking System Prototype
A hybrid opto-inertial Tracking System Prototype Faisal Kalim Faisal.kalim@tum.de Supervisor: Benjamin Busam Partners: IFL & FRAMOS Final Presentation Computer Aided Medical Procedures (CAMP) Technische
More informationPrecise Ultrasound Bone Registration with Learning-based Segmentation and Speed of Sound Calibration
Precise Ultrasound Bone Registration with Learning-based Segmentation and Speed of Sound Calibration Mehrdad Salehi 1,2, Raphael Prevost 1, José-Luis Moctezuma 3, Nassir Navab 2, and Wolfgang Wein 1 1
More informationCALIBRATION ALGORITHM FOR FREEHAND ULTRASOUND
CALIBRAION ALGORIHM FOR FREEHAND ULRASOUND 1 YAO RAO, YAO PENG 1 Aeronautic College, Shanghai University of Engineering Science, Shanghai 0160, China School of Economics & Management, Beihua University,
More informationGPU-accelerated Rendering for Medical Augmented Reality in Minimally-invasive Procedures
GPU-accelerated Rendering for Medical Augmented Reality in Minimally-invasive Procedures Matthias Wieczorek 1, André Aichert 1, Oliver Kutter 1, Christoph Bichlmeier 1, Jürgen Landes 2, Sandro Michael
More informationTowards systematic usability evaluations for the OR: an introduction to OR-Use framework
Towards systematic usability evaluations for the OR: an introduction to OR-Use framework Information Processing in Computer Aided Interventions June 27, 2012, Pisa, Italy Ali Bigdelou, Aslı Okur, Max-Emanuel
More informationWe are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists. International authors and editors
We are IntechOpen, the world s leading publisher of Open Access books Built by scientists, for scientists 3,800 116,000 120M Open access books available International authors and editors Downloads Our
More informationDeformable Registration of Bronchoscopic Video Sequences to CT Volumes with Guaranteed Smooth Output
Deformable Registration of Bronchoscopic Video Sequences to CT Volumes with Guaranteed Smooth Output Tobias Reichl 1, Xiongbiao Luo 2, Manuela Menzel 3, Hubert Hautmann 3, Kensaku Mori 4, and Nassir Navab
More informationVirtual Touch : An Efficient Registration Method for Catheter Navigation in Left Atrium
Virtual Touch : An Efficient Registration Method for Catheter Navigation in Left Atrium Hua Zhong 1, Takeo Kanade 1, and David Schwartzman 2 1 Computer Science Department, Carnegie Mellon University, USA,
More informationReal-time 3D reconstruction: applications to collision detection and surgical workflow monitoring
Real-time 3D reconstruction: applications to collision detection and surgical workflow monitoring Nassir Navab! Alexander Ladikos, Nicolas Padoy, Diana Mateus and Cedric Cagniart! Presented by Nicolas
More information3D Guide Wire Navigation from Single Plane Fluoroscopic Images in Abdominal Catheterizations
3D Guide Wire Navigation from Single Plane Fluoroscopic Images in Abdominal Catheterizations Martin Groher 2, Frederik Bender 1, Ali Khamene 3, Wolfgang Wein 3, Tim Hauke Heibel 2, Nassir Navab 2 1 Siemens
More informationVision-based endoscope tracking for 3D ultrasound image-guided surgical navigation [Yang et al. 2014, Comp Med Imaging and Graphics]
Vision-based endoscope tracking for 3D ultrasound image-guided surgical navigation [Yang et al. 2014, Comp Med Imaging and Graphics] Gustavo Sato dos Santos IGI Journal Club 23.10.2014 Motivation Goal:
More informationA Method for Tracking the Camera Motion of Real Endoscope by Epipolar Geometry Analysis and Virtual Endoscopy System
A Method for Tracking the Camera Motion of Real Endoscope by Epipolar Geometry Analysis and Virtual Endoscopy System Kensaku Mori 1,2, Daisuke Deguchi 2, Jun-ichi Hasegawa 3, Yasuhito Suenaga 2, Jun-ichiro
More informationEndoscopic Navigation for Minimally Invasive Suturing
Endoscopic Navigation for Minimally Invasive Suturing Christian Wengert 1, Lukas Bossard 1, Armin Häberling 1, Charles Baur 2, Gábor Székely 1, and Philippe C. Cattin 1 1 Computer Vision Laboratory, ETH
More informationarxiv: v3 [cs.cv] 12 Jun 2018
Markerless Inside-Out Tracking for Interventional Applications Benjamin Busam 1,2, Patrick Ruhkamp 1,2, Salvatore Virga 1, Beatrice Lentes 1, Julia Rackerseder 1, Nassir Navab 1,3, Christoph Hennersperger
More informationUniversity of Cambridge Department of Engineering Trumpington Street Cambridge CB2 1PZ United Kingdom
Comparison of Freehand 3D Ultrasound Techniques Using a Stylus P-W. Hsu, G. M. Treece, R. W. Prager N. E. Houghton and A. H. Gee CUED/F-INFENG/TR 579 June 2007 University of Cambridge Department of Engineering
More informationFully Automatic Endoscope Calibration for Intraoperative Use
Fully Automatic Endoscope Calibration for Intraoperative Use Christian Wengert, Mireille Reeff, Philippe C. Cattin, Gábor Székely Computer Vision Laboratory, ETH Zurich, 8092 Zurich, Switzerland {wengert,
More informationMarkerless Endoscopic Registration and Referencing
Markerless Endoscopic Registration and Referencing Christian Wengert 1, Philippe Cattin 1, John M. Duff 2, Charles Baur 3, and Gábor Székely 1 1 Computer Vision Laboratory, ETH Zurich, 8092 Zurich, Switzerland
More informationCoordinate Transformations, Tracking, Camera and Tool Calibration
Coordinate Transformations, Tracking, Camera and Tool Calibration Tassilo Klein, Hauke Heibel Computer Aided Medical Procedures (CAMP), Technische Universität München, Germany Motivation 3D Transformations
More informationABSTRACT 1. INTRODUCTION
Tracked ultrasound calibration studies with a phantom made of LEGO bricks Marie Soehl, Ryan Walsh, Adam Rankin, Andras Lasso, Gabor Fichtinger Queen s University, Kingston ON, Canada ABSTRACT PURPOSE:
More informationNew Approaches to Online Estimation of Electromagnetic Tracking Errors for Laparoscopic Ultrasonography
New Approaches to Online Estimation of Electromagnetic Tracking Errors for Laparoscopic Ultrasonography Marco Feuerstein 1, Tobias Reichl 2,3, Jakob Vogel 3, Joerg Traub 3, and Nassir Navab 3 1 Department
More informationAutonomous Navigation for Flying Robots
Computer Vision Group Prof. Daniel Cremers Autonomous Navigation for Flying Robots Lecture 3.2: Sensors Jürgen Sturm Technische Universität München Sensors IMUs (inertial measurement units) Accelerometers
More informationDeformable Registration of Bronchoscopic Video Sequences to CT Volumes with Guaranteed Smooth Output
Deformable Registration of Bronchoscopic Video Sequences to CT Volumes with Guaranteed Smooth Output Tobias Reichl 1, Xiongbiao Luo 2, Manuela Menzel 3, Hubert Hautmann 3, Kensaku Mori 4, and Nassir Navab
More informationIntroduction to Medical Image Registration
Introduction to Medical Image Registration Sailesh Conjeti Computer Aided Medical Procedures (CAMP), Technische Universität München, Germany sailesh.conjeti@tum.de Partially adapted from slides by: 1.
More informationInside-Out Tracking for Flexible Hand-held Nuclear Tomographic Imaging
Inside-Out Tracking for Flexible Hand-held Nuclear Tomographic Imaging Philipp Matthies 1,2, Chen-Hsuan Shih 3, Jakob Vogel 4, Álvaro Sánchez5, Tobias Lasser 1, Benjamin Frisch 1, Michael Friebe 2,6, and
More informationReal-Time 4D Ultrasound Mosaicing and Visualization
Real-Time 4D Ultrasound Mosaicing and Visualization Laura J. Brattain 1,2 and Robert D. Howe 1 1 Harvard School of Engineering and Applied Sciences, Cambrige, MA 02138 2 MIT Lincoln Laboratory, 244 Wood
More informationMulti-View 3D-Reconstruction
Multi-View 3D-Reconstruction Cedric Cagniart Computer Aided Medical Procedures (CAMP) Technische Universität München, Germany 1 Problem Statement Given several calibrated views of an object... can we automatically
More informationMarkerless Endoscopic Registration and Referencing
Markerless Endoscopic Registration and Referencing Christian Wengert 1, Philippe Cattin 1, John M. Duff 2, Charles Baur 3, and Gábor Székely 1 1 ETH Zurich - Computer Vision Laboratory, Sternwartstrasse
More informationA Novel Phantom-Less Spatial and Temporal Ultrasound Calibration Method
A Novel Phantom-Less Spatial and Temporal Ultrasound Calibration Method Ali Khamene and Frank Sauer Imaging and Visualization Dept., Siemens Corporate Research, 755 College Road East, Princeton NJ 08540,
More informationThe Concept of Evolutionary Computing for Robust Surgical Endoscope Tracking and Navigation
The Concept of Evolutionary Computing for Robust Surgical Endoscope Tracking and Navigation Ying Wan School of Computing and Communications University of Technology, Sydney This dissertation is submitted
More informationRectification and Disparity
Rectification and Disparity Nassir Navab Slides prepared by Christian Unger What is Stereo Vision? Introduction A technique aimed at inferring dense depth measurements efficiently using two cameras. Wide
More informationCalibration Method for Determining the Physical Location of the Ultrasound Image Plane
Calibration Method for Determining the Physical Location of the Ultrasound Image Plane Devin V. Amin, Ph.D. 1, Takeo Kanade, Ph.D 1., Branislav Jaramaz, Ph.D. 2, Anthony M. DiGioia III, MD 2, Constantinos
More informationMeasurement Techniques. Digital Particle Image Velocimetry
Measurement Techniques Digital Particle Image Velocimetry Heat and Mass Transfer Laboratory (LTCM) Sepideh Khodaparast Marco Milan Navid Borhani 1 Content m Introduction m Particle Image Velocimetry features
More informationCreating a Vision Channel for Observing Deep-Seated Anatomy in Medical Augmented Reality
Creating a Vision Channel for Observing Deep-Seated Anatomy in Medical Augmented Reality A Cut-Away Technique for In-Situ Visualization Felix Wimmer 1, Christoph Bichlmeier 1, Sandro M. Heining 2, Nassir
More informationComputed Photography - Final Project Endoscope Exploration on Knee Surface
15-862 Computed Photography - Final Project Endoscope Exploration on Knee Surface Chenyu Wu Robotics Institute, Nov. 2005 Abstract Endoscope is widely used in the minimally invasive surgery. However the
More informationImproved Navigated Spine Surgery Utilizing Augmented Reality Visualization
Improved Navigated Spine Surgery Utilizing Augmented Reality Visualization Zein Salah 1,2, Bernhard Preim 1, Erck Elolf 3, Jörg Franke 4, Georg Rose 2 1Department of Simulation and Graphics, University
More informationBolus Tracking in Colon MRI
Bolus Tracking in Colon MRI Project Presentation Christian Harrer, Andreas Keil, Dr. Sonja Buhmann (Klinikum Großhadern) 2 August 2007 Chair for Computer Aided Medical Procedures & Augmented Reality Department
More informationLecture 3 Sections 2.2, 4.4. Mon, Aug 31, 2009
Model s Lecture 3 Sections 2.2, 4.4 World s Eye s Clip s s s Window s Hampden-Sydney College Mon, Aug 31, 2009 Outline Model s World s Eye s Clip s s s Window s 1 2 3 Model s World s Eye s Clip s s s Window
More informationEnabling Technologies for Robot Assisted Ultrasound Tomography
Enabling Technologies for Robot Assisted Ultrasound Tomography Seminar Presentation By: Fereshteh Aalamifar Team Members: Rishabh Khurana, Fereshteh Aalamifar Mentors: Emad Boctor, Iulian Iordachita, Russell
More informationUse of Ultrasound and Computer Vision for 3D Reconstruction
Use of Ultrasound and Computer Vision for 3D Reconstruction Ruben Machucho-Cadena 1, Eduardo Moya-Sánchez 1, Sergio de la Cruz-Rodríguez 2, and Eduardo Bayro-Corrochano 1 1 CINVESTAV, Unidad Guadalajara,
More informationDevelopment of Pseudo 3D Visualization System by Superimposing Ultrasound Images
Development of Pseudo 3D Visualization stem b uperimposing Ultrasound Images Yumi Iwashita, hinji Tarumi, Ro Kurazume Graduate chool of Information cience and Electrical Engineering Kushu Universit, Fukuoka,
More informationIntegrated System for Planning Peripheral Bronchoscopic Procedures
Integrated System for Planning Peripheral Bronchoscopic Procedures Jason D. Gibbs, Michael W. Graham, Kun-Chang Yu, and William E. Higgins Penn State University Dept. of Electrical Engineering University
More informationUltrasound Specific Similarity Measures for Three-Dimensional Mosaicing
Ultrasound Specific Similarity Measures for Three-Dimensional Mosaicing Christian Wachinger and Nassir Navab Computer Aided Medical Procedures (CAMP), Technische Universität München, Boltzmannstr. 3, 85748
More informationStereo Matching! Christian Unger 1,2, Nassir Navab 1!! Computer Aided Medical Procedures (CAMP), Technische Universität München, Germany!!
Stereo Matching Christian Unger 12 Nassir Navab 1 1 Computer Aided Medical Procedures CAMP) Technische Universität München German 2 BMW Group München German Hardware Architectures. Microprocessors Pros:
More informationOut-of-plane motion estimation based on a Rician-Inverse Gaussian model of RF ultrasound signals: speckle tracking without fully developed speckle
Cum Laude Poster Award Out-of-plane motion estimation based on a Rician-Inverse Gaussian model of RF ultrasound signals: speckle tracking without fully developed speckle N. Afsham, M. Najafi, P. Abolmaesumi,
More informationBackward-Warping Ultrasound Reconstruction for Improving Diagnostic Value and Registration
Backward-Warping Ultrasound Reconstruction for Improving Diagnostic Value and Registration Wolfgang Wein 1, Fabian Pache 1,BarbaraRöper 2, and Nassir Navab 1 1 Chair for Computer Aided Medical Procedures
More informationULTRASONOGRAPHY is an appealing technology to
IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 28, NO. 6, JUNE 2009 951 Magneto-Optical Tracking of Flexible Laparoscopic Ultrasound: Model-Based Online Detection and Correction of Magnetic Tracking Errors
More informationMulti-view Surface Inspection Using a Rotating Table
https://doi.org/10.2352/issn.2470-1173.2018.09.iriacv-278 2018, Society for Imaging Science and Technology Multi-view Surface Inspection Using a Rotating Table Tomoya Kaichi, Shohei Mori, Hideo Saito,
More informationComputer Graphics. Lecture 9 Environment mapping, Mirroring
Computer Graphics Lecture 9 Environment mapping, Mirroring Today Environment Mapping Introduction Cubic mapping Sphere mapping refractive mapping Mirroring Introduction reflection first stencil buffer
More informationACCURACY OF MAP DIGITIZING BY USING DIGITAL CAMERA
ACCURACY OF MAP DIGITIZING BY USING DIGITAL CAMERA Takashi YAMAMOTO*, Jong-Hyeok JEONG*, Masataka TAKAGI*, Masataka TAKAGI* Kochi University of Technology* ABSTRACT: In the past, a large accurate image
More informationManifold Learning for Image-Based Breathing Gating with Application to 4D Ultrasound
Manifold Learning for Image-Based Breathing Gating with Application to 4D Ultrasound Christian Wachinger, Mehmet Yigitsoy, Nassir Navab Computer Aided Medical Procedures (CAMP), TUM, Munich, Germany {wachinge,
More informationINTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1. Modifications for P551 Fall 2013 Medical Physics Laboratory
INTRODUCTION TO MEDICAL IMAGING- 3D LOCALIZATION LAB MANUAL 1 Modifications for P551 Fall 2013 Medical Physics Laboratory Introduction Following the introductory lab 0, this lab exercise the student through
More informationChapter 11 Application of High Speed Imaging in Particle Dynamics Study with Explosives
Chapter 11 Application of High Speed Imaging in Particle Dynamics Study with Explosives Elena Jacobs and Vilem Petr Abstract High-speed imaging can provide invaluable information during any explosive testing.
More informationMR-Mirror: A Complex of Real and Virtual Mirrors
MR-Mirror: A Complex of Real and Virtual Mirrors Hideaki Sato 1, Itaru Kitahara 1, and Yuichi Ohta 1 1 Department of Intelligent Interaction Technologies, Graduate School of Systems and Information Engineering,
More informationCamera Model and Calibration
Camera Model and Calibration Lecture-10 Camera Calibration Determine extrinsic and intrinsic parameters of camera Extrinsic 3D location and orientation of camera Intrinsic Focal length The size of the
More informationAutonomous Navigation for Flying Robots
Computer Vision Group Prof. Daniel Cremers Autonomous Navigation for Flying Robots Lecture 7.2: Visual Odometry Jürgen Sturm Technische Universität München Cascaded Control Robot Trajectory 0.1 Hz Visual
More informationReal-time Tissue Tracking with B-Mode Ultrasound Using Speckle and Visual Servoing
Real-time Tissue Tracking with B-Mode Ultrasound Using Speckle and Visual Servoing Alexandre Krupa, Gabor Fichtinger, and Gregory D. Hager IRISA - INRIA Rennes, France, alexandre.krupa@irisa.fr Engineering
More informationActive Echo: A New Paradigm for Ultrasound Calibration
Active Echo: A New Paradigm for Ultrasound Calibration Xiaoyu Guo, Alexis Cheng, Haichong K. Zhang, Hyun-Jae Kang, Ralph Etienne-Cummings, and Emad M. Boctor The Johns Hopkins University, Baltimore, MD
More informationRay tracing based fast refraction method for an object seen through a cylindrical glass
20th International Congress on Modelling and Simulation, Adelaide, Australia, 1 6 December 2013 www.mssanz.org.au/modsim2013 Ray tracing based fast refraction method for an object seen through a cylindrical
More information3-D D Euclidean Space - Vectors
3-D D Euclidean Space - Vectors Rigid Body Motion and Image Formation A free vector is defined by a pair of points : Jana Kosecka http://cs.gmu.edu/~kosecka/cs682.html Coordinates of the vector : 3D Rotation
More informationRecovering the Full Pose from a Single Keyframe
Recovering the Full Pose from a Single Keyframe Pierre Fite Georgel Selim Benhimane Jürgen Sotke Nassir Navab CAMP - TU München METAIO CAMP - TU München CAMP - TU München Abstract Photo-based Augmentation
More informationAutonomous Navigation for Flying Robots
Computer Vision Group Prof. Daniel Cremers Autonomous Navigation for Flying Robots Lecture 3.1: 3D Geometry Jürgen Sturm Technische Universität München Points in 3D 3D point Augmented vector Homogeneous
More informationTrans-skull Imaging System by Ultrasonic Array Probe
Proceedings of the 9 IEEE International Conference on Systems, Man, and Cybernetics San Antonio, TX, USA - October 9 Trans-skull Imaging System by Ultrasonic Array Probe Genta Hiramatsu, Yuichiro Ikeda,
More informationMech. Engineering, Comp. Science, and Rad. Oncology Departments. Schools of Engineering and Medicine, Bio-X Program, Stanford University
Mech. Engineering, Comp. Science, and Rad. Oncology Departments Schools of Engineering and Medicine, Bio-X Program, Stanford University 1 Conflict of Interest Nothing to disclose 2 Imaging During Beam
More informationECE-161C Cameras. Nuno Vasconcelos ECE Department, UCSD
ECE-161C Cameras Nuno Vasconcelos ECE Department, UCSD Image formation all image understanding starts with understanding of image formation: projection of a scene from 3D world into image on 2D plane 2
More informationA Robust Meshing and Calibration Approach for Sensorless Freehand 3D Ultrasound
A Robust Meshing and Calibration Approach for Sensorless Freehand 3D Ultrasound Hassan Rivaz a,emadboctor a, and Gabor Fichtinger a,b,c Department of a Computer Science, b Mechanical Engineering, c Radiology,
More informationAutonomous Mobile Robot Design
Autonomous Mobile Robot Design Topic: EKF-based SLAM Dr. Kostas Alexis (CSE) These slides have partially relied on the course of C. Stachniss, Robot Mapping - WS 2013/14 Autonomous Robot Challenges Where
More informationRendering. Converting a 3D scene to a 2D image. Camera. Light. Rendering. View Plane
Rendering Pipeline Rendering Converting a 3D scene to a 2D image Rendering Light Camera 3D Model View Plane Rendering Converting a 3D scene to a 2D image Basic rendering tasks: Modeling: creating the world
More informationAutonomous Navigation for Flying Robots
Computer Vision Group Prof. Daniel Cremers Autonomous Navigation for Flying Robots Lecture 7.1: 2D Motion Estimation in Images Jürgen Sturm Technische Universität München 3D to 2D Perspective Projections
More informationUniversity of Cambridge Department of Engineering Trumpington Street Cambridge CB2 1PZ United Kingdom.
MULTI-DIRECTIONAL SCATTERING MODELS FOR 3D ULTRASOUND U. Z. Ijaz, R. J. Housden, G. M. Treece R. W. Prager, and A. H. Gee CUED/F-INFENG/TR 661 January 2011 University of Cambridge Department of Engineering
More informationComputed tomography (Item No.: P )
Computed tomography (Item No.: P2550100) Curricular Relevance Area of Expertise: Biology Education Level: University Topic: Modern Imaging Methods Subtopic: X-ray Imaging Experiment: Computed tomography
More information3-D Ultrasound Probe Calibration for Computer-Guided Diagnosis and Therapy
3-D Ultrasound Probe Calibration for Computer-Guided Diagnosis and Therapy Michael Baumann 1,2, Vincent Daanen 1, Antoine Leroy 2, and Jocelyne Troccaz 1 1 TIMC Laboratory, GMCAO Department, Institut d
More informationSphere Extraction in MR Images with Application to Whole-Body MRI
Sphere Extraction in MR Images with Application to Whole-Body MRI Christian Wachinger a, Simon Baumann a, Jochen Zeltner b, Ben Glocker a, and Nassir Navab a a Computer Aided Medical Procedures (CAMP),
More informationA New and General Method for Blind Shift-Variant Deconvolution of Biomedical Images
A New and General Method for Blind Shift-Variant Deconvolution of Biomedical Images Moritz Blume 1,Darkoikic 1, Wolfgang Wein 1,2, and Nassir Navab 1 1 Computer Aided Medical Procedures (CAMP), Technische
More informationAutomatic Patient Registration for Port Placement in Minimally Invasive Endoscopic Surgery
Automatic Patient Registration for Port Placement in Minimally Invasive Endoscopic Surgery Marco Feuerstein 1,2, Stephen M. Wildhirt 2, Robert Bauernschmitt 2, and Nassir Navab 1 1 Computer Aided Medical
More informationNew Sony DepthSense TM ToF Technology
ADVANCED MATERIAL HANDLING WITH New Sony DepthSense TM ToF Technology Jenson Chang Product Marketing November 7, 2018 1 3D SENSING APPLICATIONS Pick and Place Drones Collision Detection People Counting
More informationFreehand Three-Dimensional Ultrasound Calibration
Freehand Three-Dimensional Ultrasound Calibration Po-Wei Hsu Department of Engineering Girton College University of Cambridge A thesis submitted for the degree of Doctor of Philosophy December 2007 Acknowledgements
More informationULTRASOUND (US) has become one of the standard
538 IEEE TRANSACTIONS ON MEDICAL IMAGING, VOL. 36, NO. 2, FEBRUARY 2017 Towards MRI-Based Autonomous Robotic US Acquisitions: A First Feasibility Study Christoph Hennersperger, Bernhard Fuerst, Salvatore
More informationIntraoperative Ultrasound Probe Calibration in a Sterile Environment
Intraoperative Ultrasound Probe Calibration in a Sterile Environment Ramtin Shams 1, Raúl San José Estépar 2, Vaibhav Patil 2, and Kirby G. Vosburgh 2,3 1 CECS, The Australian National University, Canberra
More informationAdaptive Branch Tracing and Image Sharpening for Airway Tree Extraction in 3-D Chest CT
Adaptive Branch Tracing and Image Sharpening for Airway Tree Extraction in 3-D Chest CT Marco Feuerstein 1, Takayuki Kitasaka 2,3, Kensaku Mori 1,3 1 Graduate School of Information Science, Nagoya University,
More informationSemi-Automatic Segmentation of the Patellar Cartilage in MRI
Semi-Automatic Segmentation of the Patellar Cartilage in MRI Lorenz König 1, Martin Groher 1, Andreas Keil 1, Christian Glaser 2, Maximilian Reiser 2, Nassir Navab 1 1 Chair for Computer Aided Medical
More informationIntrinsic and Extrinsic Camera Parameter Estimation with Zoomable Camera for Augmented Reality
Intrinsic and Extrinsic Camera Parameter Estimation with Zoomable Camera for Augmented Reality Kazuya Okada, Takafumi Taketomi, Goshiro Yamamoto, Jun Miyazaki, Hirokazu Kato Nara Institute of Science and
More informationOptics B/C. Mitchell Gu
Mitchell Gu Disclaimer: This presentation was prepared using draft rules. There may be some changes in the final copy of the rules. Overview A two-part event featuring a written test on geometric and physical
More informationVision-Based Hand Detection for Registration of Virtual Objects in Augmented Reality
International Journal of Future Computer and Communication, Vol. 2, No. 5, October 213 Vision-Based Hand Detection for Registration of Virtual Objects in Augmented Reality Kah Pin Ng, Guat Yew Tan, and
More informationICRP Symposium on Radiological Protection Dosimetry
ICRP Symposium on Radiological Protection Dosimetry Tokyo February 18 th, 2016 M. Zankl a, J. Becker a, K.F. Eckerman b, W.E. Bolch c, R. Behrens d a Helmholtz Zentrum München, Neuherberg, Germany b Oak
More information3D Ultrasound System Using a Magneto-optic Hybrid Tracker for Augmented Reality Visualization in Laparoscopic Liver Surgery
3D Ultrasound System Using a Magneto-optic Hybrid Tracker for Augmented Reality Visualization in Laparoscopic Liver Surgery Masahiko Nakamoto 1, Yoshinobu Sato 1, Masaki Miyamoto 1, Yoshikazu Nakamjima
More informationRobot Calibration for Precise Ultrasound Image Acquisition
Abstract Robot Calibration for Precise Ultrasound Image Acquisition Pedro M. B. Torres 1,2, Paulo J. S. Gonçalves 1,2, Jorge M. M. Martins 2 1 Polytechnic Institute of CasteloBranco, School of Technology,
More informationInteraction-Free Calibration for Optical See-Through Head-Mounted Displays based on 3D Eye Localization
1/23 Interaction-Free Calibration for Optical See-Through Head-Mounted Displays based on 3D Eye Localization Yuta Itoh and Gudrun Klinker TU München Information 2/23 This work is a part of EDUSAFE project
More informationTrajectory-based Deformation Correction in Ultrasound Images
Trajectory-based Deformation Correction in Ultrasound Images The MIT Faculty has made this article openly available. Please share how this access benefits you. Your story matters. Citation As Published
More informationCAMERA CONSTANT IN THE CASE OF TWO MEDIA PHOTOGRAMMETRY
CAMERA CONSTANT IN THE CASE OF TWO MEDIA PHOTOGRAMMETRY Panagiotis Agrafiotis and Andreas Georgopoulos Laboratory Of Photogrammetry, School of Rural and Surveying Engineering National Technical University
More informationMiniature faking. In close-up photo, the depth of field is limited.
Miniature faking In close-up photo, the depth of field is limited. http://en.wikipedia.org/wiki/file:jodhpur_tilt_shift.jpg Miniature faking Miniature faking http://en.wikipedia.org/wiki/file:oregon_state_beavers_tilt-shift_miniature_greg_keene.jpg
More informationModel-based Visual Tracking:
Technische Universität München Model-based Visual Tracking: the OpenTL framework Giorgio Panin Technische Universität München Institut für Informatik Lehrstuhl für Echtzeitsysteme und Robotik (Prof. Alois
More informationNew Sony DepthSense TM ToF Technology
ADVANCED MATERIAL HANDLING WITH New Sony DepthSense TM ToF Technology Jenson Chang Product Marketing November 7, 2018 1 3D SENSING APPLICATIONS Pick and Place Drones Collision Detection People Counting
More information