Test Report modcon - PS88A6M
|
|
- Lora Ray
- 5 years ago
- Views:
Transcription
1 modcon - PS886M Transmission Characteristics of PS886M /CT6 PS886M shielded CT6 plug fulfills the requirements for electrical transmission performance according to IEC ; detail specification for 8-way, shielded, free and fixed connectors, for data transmissions with frequencies up to 5 MHz": 21 and according to IEC1181 Ed. 2.2, Cat 6 : 211 : - insertion loss - return loss - near-end crosstalk - far-end crosstalk - TCl - TCTl - transfer impedance Different length (,5m, 1 m, 13m) of CT 6 balanced cables assembled to PS886M fulfill the RF performance (return loss, near-end crosstalk) according to IEC : 21 "Specification for the testing of balanced and coaxial informationtechnology cabling - Part 2: Cords as specified in ISOIIEC 1181 and related standards". Date: Page 1 of 11
2 modcon - PS886M 1. Insertion loss, -,1, -,1 Insertion loss of sample 1 Insertion loss [db] -,2 -,3 -,4 -,5 -,6 -,7 -,8 -,8 1M 1M 2M 3M 4M 5M 6M -,2 -,3 -,4 -,5 -,6 -,7 INELCO CT6 PS886M, -,1, -,1 Insertion loss of sample 2 Insertion loss [db] -,2 -,3 -,4 -,5 -,6 -,7 -,7 -,8 -,8 1M 1M 2M 3M 4M 5M 6M -,2 -,3 -,4 -,5 -,6 INELCO CT6 PS886M Date: Page 2 of 11
3 modcon - PS886M 2. Return loss Return loss of sample 1 Return loss [db] 1M 1M 2M 3M 4M 5M 6M plug side INELCO CT6 PS886M Return loss [db] 1M 1M 2M 3M 4M 5M 6M plug side Return loss of sample 2 INELCO CT6 PS886M Date: Page 3 of 11
4 modcon - PS886M 3. Near-end crosstalk Near-end crosstalk of sample 1 Near-end crosstalk [db] -9 Near-end crosstalk between... pairs 12/36 pairs 12/45 pairs 12/78 pairs 36/45 pairs 36/78 pairs 45/ M 1M 2M 3M 4M 5M 6M -9 INELCO CT6 PS886M Near-end crosstalk of sample 2 Near-end crosstalk [db] Near-end crosstalk between pairs 12/36-9 pairs 12/45 pairs 12/78 pairs 36/45 pairs 36/78 pairs 45/ M 1M 2M 3M 4M 5M 6M INELCO CT6 PS886M Date: Page 4 of 11
5 modcon - PS886M 4. Far-end crosstalk Far-end crosstalk of sample 1 Far-end crosstalk [db] -9 Far-end crosstalk between... pairs 12/36 pairs 12/45 pairs 12/78 pairs 36/45 pairs 36/78 pairs 45/78 1M 1M 2M 3M 4M 5M 6M -9 INELCO CT6 PS886M Far-end crosstalk [db] -9 Far-end crosstalk between... pairs 12/36 pairs 12/45 pairs 12/78 pairs 36/45 pairs 36/78 pairs 45/78 1M 1M 2M 3M 4M 5M 6M -9 Far-end crosstalk of sample 2 INELCO CT6 PS886M Date: Page 5 of 11
6 modcon - PS886M 5. TCL of connecting TCL of sample 1 INELCO CT6 PS886M TCL [db] 1M 1M 2M 3M 4M 5M 6M TCL of sample 2 INELCO CT6 PS886M TCL [db] 1M 1M 2M 3M 4M 5M 6M Date: Page 6 of 11
7 modcon - PS886M 6. TCTL TCTL of sample 1 TCTL [db] 1M 1M 2M 3M 4M 5M 6M TCTL of sample 2 TCTL [db] 1M 1M 2M 3M 4M 5M 6M Date: Page 7 of 11
8 modcon - PS886M 7. Transfer impedance 1. Limit for connecting hardware acc. to ISO IEC 1181: Transfer impedance of sample 3, 4 Transfer impedance [mω] with Cat 7 cable; couple length 39cm sample 3 sample 4 1 3k 1M Test setup acc. to IEC , Test 26e: 28 ; triaxial method 1 1M 1M Frequency [Hz] Date: Page 8 of 11
9 Cable ID: , PC-CT6:,5M Test Summary: Date / Time: :58:53 Operator: P. Pardal Model: DTX-18 Headroom 2.1 db (NEXT 36-45) Software Version: 2.63 Main S/N: Test Limit: ISO Patch Cord Cat6.5m Limits Version: 1.81 Remote S/N: Cable Type: Cat 6 FTP NVP: 74.% Main dapter: DTX-PC6/MN ISO/IEC Remote dapter: DTX-PC6/MN ISO/IEC Length (m) [Pair 12].4 Prop. Delay (ns) [Pair 45] 3 Delay Skew (ns) [Pair 45] 1 Resistance (ohms) [Pair 45].2 Worst Case Margin Worst Case Value MIN SR MIN SR Worst Pair NEXT (db) Freq. (MHz) Limit (db) MIN SR MIN SR Worst Pair RL (db).* 3. Freq. (MHz) Limit (db) Wire Map (T568B).4 m * Measurement is within the accuracy limits of the instrument. LinkWare Version 7.2
10 Cable ID: , PC-CT6: 1M Test Summary: Date / Time: :9:15 Operator: P. Pardal Model: DTX-18 Headroom 2.3 db (NEXT 36-45) Software Version: 2.63 Main S/N: Test Limit: ISO Patch Cord Cat6 1.m Limits Version: 1.81 Remote S/N: Cable Type: Cat 6 FTP NVP: 74.% Main dapter: DTX-PC6/MN ISO/IEC Remote dapter: DTX-PC6/MN ISO/IEC Length (m) [Pair 12] 1.1 Prop. Delay (ns) [Pair 45] 6 Delay Skew (ns) [Pair 45] 1 Resistance (ohms) [Pair 45].4 Worst Case Margin Worst Case Value MIN SR MIN SR Worst Pair NEXT (db) Freq. (MHz) Limit (db) MIN SR MIN SR Worst Pair RL (db).3* 3.6 Freq. (MHz) Limit (db) Wire Map (T568B) 1.1 m * Measurement is within the accuracy limits of the instrument. LinkWare Version 7.2
11 Cable ID: , PC-CT6: 13M Test Summary: Date / Time: :8:18 Operator: P. Pardal Model: DTX-18 Headroom 4.6 db (NEXT 36-45) Software Version: 2.63 Main S/N: Test Limit: ISO Patch Cord Cat6 1.m Limits Version: 1.81 Remote S/N: Cable Type: Cat 6 FTP NVP: 74.% Main dapter: DTX-PC6/MN ISO/IEC Remote dapter: DTX-PC6/MN ISO/IEC Length (m) [Pair 78] 13.5 Prop. Delay (ns) [Pair 12] 62 Delay Skew (ns) [Pair 12] 1 Resistance (ohms) [Pair 45] 3.7 Worst Case Margin Worst Case Value MIN SR MIN SR Worst Pair NEXT (db) Freq. (MHz) Limit (db) MIN SR MIN SR Worst Pair RL (db).3* 4.3 Freq. (MHz) Limit (db) Wire Map (T568B) 13.5 m * Measurement is within the accuracy limits of the instrument. LinkWare Version 7.2
Independent Testing - For End User Confidence
Independent Testing - For End User Confidence QUALIFICATION TESTING OF SCREENED CATEGORY 5 (CAT. 5e) CONNECTING HARDWARE ACCORDING TO REQUIREMENTS OF PROPOSED CENELEC 2nd EDITION EN 50173, PROPOSED ISO/IEC
More informationIndependent Testing - For End User Confidence
Independent Testing - For End User Confidence QUALIFICATION TESTING OF SCREENED CATEGORY 6 A ISO/IEC, CENELEC & TIA CONNECTING HARDWARE ACCORDING TO REQUIREMENTS OF EDITION 2.2 OF ISO/IEC 11801, CENELEC
More informationR&Mfreenet Advanced Cat 6A Shielded Connection Module
R&Mfreenet Advanced R&Mfreenet Advanced Cat 6A Connection Module The R&Mfreenet Cat 6A shielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions and
More informationANSI/TIA-568-C Cat 6A Field Test Specifications
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the certification of Category 6A Permanent Links. It is offered as a general guide. Suitability
More informationAMP-TWIST* 6S Series SL Jack
Product Specification 108-93003 16/Mar/2011 Rev E AMP-TWIST* 6S Series SL Jack 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, AMP- TWIST*
More informationTest report number CRT-001 Project number CRT-001
3933 U Route 11 Cortland, NY 1345 Telephone: (7) 753-6711 Facsimile: (7) 758-59 www.intertek.com January 6, 2 L-Com Inc 45 Beechwood Drive L-Com Global Connectivity North Andover, MA 1845 Test report number
More informationProduct information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m
Product information Patch Cord Cat. 6A, S/FTP, 4P, LSFRZH, gray, RJ45/s- RJ45/s, 1.0 m R509858 101376015 10 pcs Cable identification: S/FTP Outer jacket: LSFRZH Conductor diameter copper strand: AWG 26/7
More informationChapter 3 Certifying Twisted Pair Cabling
Chapter 3 Certifying Twisted Pair Cabling Setting the Reference The reference procedure sets a baseline for insertion loss, ELFEXT, and dc resistance measurements. Run the tester s reference procedure
More informationUpdated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC Augmented RJ45
Updated Test Data for Channels based on Proposed Category 8.2 Connectivity IEC 61076-3-110 Augmented RJ45 Rich Marowsky, Bel Stewart Yakov Belopolsky, Bel Stewart IEEE P802.3bq 40GBASE-T Task force San
More informationLANcat System 6 with C5e Performance Module. User Manual Addendum
LANcat System 6 with C5e Performance Module User Manual Addendum Datacom Textron may make improvements or additions to this publication or their products at any time without notice. Datacom Textron shall
More informationPro 21/Galea/Sistena socket for LCS 6 Category 6
87045 LIMOGES Cedex Telephone number : + 33 5 55 06 87 87 Fax number : + 33 5 55 06 88 88 Pro 21/Galea/Sistena socket for LCS 6 7758 23/28/30//41/47 CONTENTS PAGE UTP/FTP 1. General characteristics...
More informationLCS² Cat. 6A RJ45 Socket
87045 LIMOGES Cedex Telephone: +33 (0)5 55 06 87 87 - Fax: +33 (0)5 55 06 88 88 Céliane TM Page 1. General characteristics....1 2. Presentation...1 3. Installation...1 4. Technical characteristics...1
More informationR&Mfreenet Advanced Cat 6 A Unshielded Connection Module
R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions
More informationDTX-PCxxS. Users Manual. Patch Cord Test Adapters
DTX-PCxxS Patch Cord Test Adapters Users Manual January 2011 2011 Fluke Corporation. All rights reserved. Printed in USA. All product names are trademarks of their respective companies. LIMITED WARRANTY
More informationANSI/TIA-568-C Cat 6 Field Test Specifications
This document has been prepared to aid consultants or engineers in developing contractual specifications covering the certification of Category 6 Permanent Links. It is offered as a general guide. Suitability
More informationTelegärtner Point of View
Telegärtner Point of View Category 6 A Patch Cords 10 Gigabit per second is the highest data rate that can be transmitted over copper cables in structured cabling over a distance of 100 metres. At this
More informationNew standards that have led to higher speeds and new cable categories. Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks
New standards that have led to higher speeds and new cable categories Mike Gengler Sales Area VP, Asia/Pac & Japan Fluke Networks Three Realities of Networking #1 - Networks Never Go Slower Plan for higher
More informationMosaic TM LCS2 Cat. 6 RJ 45 socket
870 LIMOGES Cedex Telephone : + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 Cat. 6 Page 765 61 765 44 765 94 1. General characteristics...1 2. Presentation...2 3. Installation....2 4.
More informationMosaic TM LCS2 Cat. 6 RJ 45 socket
870 LIMOGES Cedex Telephone : + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 Cat. 6 Page 765 61 765 44 765 94 1. General characteristics....1 2. Presentation...2 3. Installation...2 4.
More informationCat 6 (500 MHz) UTP solid cable (PVC sheath)
JetLan is the only structured cabling system that includes all the passive elements required by the installation or modification of your data networks, as it offers all the options for high performance
More informationIEEE RTPGE. Optimisation of physical layer components for RTPGE. Thomas Müller, Gunnar Armbrecht, Stephan Kunz (Rosenberger)
Optimisation of physical layer components for RTPGE Thomas Müller, Gunnar Armbrecht, Stephan Kunz (Rosenberger) Supporters: Mehmet Tazebay (Broadcom) Thomas Suermann (NXP) Rosenberger Hochfrequenztechnik
More informationA FLUKE networks DTX 1800 Cable Analyzer és DTX Fiber Modules
A FLUKE networks DTX 1800 Cable Analyzer és DTX Fiber Modules Rövidített leírás és kezelési utasítás The DTX Series CableAnalyzers are rugged, hand-held instruments used to certify, troubleshoot, and document
More informationCable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification
General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall obtain authorization from
More informationRecent Changes in the Physical Layer (Chapter 8) for DeviceNet and EtherNet/IP
Recent Changes in the Physical Layer (Chapter 8) for DeviceNet and EtherNet/IP Brad Woodman Engineering Supervisor Molex Presented at the ODVA 2014 Industry Conference & 16 th Annual Meeting March 11-13,
More informationCertification for 10G copper cabling
Certification for 10G copper cabling Presented by Eric Lie, Sales Manager 1 Introduction This presentation is intended to provide an overview of the 10GBASE-T requirements for cabling The applicable standards
More informationWT-380 Automated Switching Solution For 48 Twisted Pairs or 40 Twisted Quad Cables
WT-380 defines multi-line, vectored performance testing of Gfast modems using profiles 106 or 212. This is done over 48 (or 40) short or long loops of twisted pair (or twisted quad) cables. The Telebyte
More information10G Ethernet Over Structured Copper Cabling
I T I n f r a s t r u c t u r e S o l u t i o n s Note: The following technical article was current at the time it was published. However, due to changing technologies and standards updates, some of the
More informationHOW DO I KNOW IF THE CABLING FIRM I AM TALKING WITH IS REALLY QUALIFIED? Wire is Wire Q & A. Cabling is an Investment. Ask the Right Questions
Wire is Wire Anybody can install it, right? Just about anyone can run wire but a proper installation by a trained installer allows your technology investment to work at its full potential! Cabling is an
More informationWireScope 155 SCOPE. Agilent Wirescope 155 Specs Provided by The Performance Leader in Hand-Held Network Tools
Agilent Wirescope 155 Specs Provided by www.aaatesters.com WireScope 155 Tests installed cabling for compliance with TIA 568A Category 5 and ISO 11801 Class D specifications. Fully implements TIA TSB-67
More informationDTX-PCU6S. Users Manual. Patch Cord Adapters
DTX-PCU6S Patch Cord Adapters Users Manual November 2004 2004 Fluke Corporation. All rights reserved. All product names are trademarks of their respective companies. LIMITED WARRANTY & LIMITATION OF LIABILITY
More informationCable into the Future: Industrial Ethernet with 10 Gbps
Cable into the Future: Industrial Ethernet with 10 Gbps A White Paper presented by: Bernd Horrmeyer Industrial Network Cabling Specialist Phoenix Contact GmBH & Co. KG Blomberg, Germany Phoenix Contact
More informationCategory 8 paves the way for IEEE 40GBASE-T. David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope
Category 8 paves the way for IEEE 40GBASE-T David Hughes RCDD/DCDC/NTS Senior Technical Manager MEA CommScope Agenda Market need for 40 G over balanced twisted pair cabling Standards ISO/IEC 11801-99-1
More informationINTERNATIONAL STANDARD
ISO/IEC 11801-1 INTERNATIONAL STANDARD Edition 1.0 2017-11 Information technology Generic cabling for customer premises Part 1: General requirements INTERNATIONAL ELECTROTECHNICAL COMMISSION ICS 35.200
More informationNETWORK CONNECTIVITY SYSTEMS
NETWORK CONNECTIVITY SYSTEMS Patch Cords/Testers JS-FTP Category 6A Patch Cords S-FTP Category 6 Patch Cords S-FTP Category 5E Patch Cords UTP Category 6 Patch Cords UTP Category 5E Patch Cords T-Adapters
More informationField-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.
FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color
More informationLanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance
LanTEK III FiberTEK III Certifier for Copper and Fibre Cabling Proof of Performance LanTEK III FiberTEK III The LanTEK III is an easy to use cable certifier that meets existing TIA and ISO/IEC performance
More information/June/2013 Rev B
Qualification Test Report 501-93016 14/June/2013 Rev B AMP-TWIST* 6S Series SL Jack 1. INTRODUCTION 1.1 Purpose Testing were performed on AMP-TWIST* 6S Series SL Jack, to determine its conformance to the
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC 15018 First edition 2004-06 Information technology Generic cabling for homes ISO/IEC 2004 All rights reserved. Unless otherwise specified, no part of this publication may
More informationDeviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved.
TC500 Ethernet Cabling Certifier Operation Manual Version 1.13 Deviser Part No.: TC500-DL Deviser Instruments, Inc. All rights reserved. Warranty This instrument is guaranteed for a period of 2 years
More information[0.057] 5.8 [0.23]
Product Specification 7 March 13 Rev A1 SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used
More information[0.057] 5.8 [0.23]
Product Specification 7 June 13 Rev B SL Series Jacks, Category 6 1. SCOPE 1.1 Content This specification covers performance, tests and quality requirements for AMP NETCONNECT*, Category 6 SL Jacks used
More informationCat.8 Shielded Keystone Jack Description
Description RiT s CAT8 Shielded Keystone Jacks are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations. Phosphor
More informationThe AMP NETCONNECT Category 6 Cabling System
The AMP NETCONNECT Category 6 Cabling System 2 Table of Contents TABLE OF CONTENTS...3 PERSPECTIVE...4 WHY INSTALL NEXT GENERATION CABLING SYSTEMS?...4 MEGAHERTZ VS. MEGABITS...4 PLANNING FOR THE FUTURE...5
More informationCat.8 Shielded Field Termination Plug Description
Description RiT s CAT8 Shielded field termination plug are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations.
More informationThe AMP NETCONNECT Category 6 Cabling System
The AMP NETCONNECT Category 6 Cabling System Table of Contents TABLE OF CONTENTS... 3 PERSPECTIVE... 4 WHY INSTALL NEXT GENERATION CABLING SYSTEMS?... 4 MEGAHERTZ VS. MEGABITS... 4 PLANNING FOR THE FUTURE...
More informationTECHNICAL DATA SHEET Family code C2424SOLPCORD CAT 6 UTP Solid. version 1 LSNH PATCHCORD date page 1/5
page 1/5 Application: High Density Switch & Hub Working area cord and telecommunications equipment cord in Local Area Networking environments Support current and future Category 6 applications, such as:
More informationSingle-pair cabling channel specifications
Single-pair cabling channel specifications IEEE P802.3cg 10SPE Task Force October 25, 2017 Dave Hess, CORD DATA 10/25/2017 hess_10spe_01_1025 1 Overview JMTG organization and scope JMTG projects related
More informationQualified Partner Programme QPP. Cat.6 Channel Meassurement Issues Felice Guarna
Qualified Partner Programme QPP Cat.6 Channel Meassurement Issues Felice Guarna Agenda Channel and link definitions Why measure a channel? Patch cord affects on link performance The challenge of channel
More informationLanTEK III FiberTEK III. Certifier for Copper and Fibre Cabling. Proof of Performance
LanTEK III FiberTEK III Certifier for Copper and Fibre Cabling Proof of Performance LanTEK III FiberTEK III The LanTEK III is an easy to use cable certifier that meets existing TIA and ISO/IEC performance
More informationTIA TR-42 Liaison to IEEE
TIA TR-42 Liaison to IEEE Val Rybinski Vice-Chair, TR-42.7 May 2005 Austin, TX Impact of PHY Capabilities Extended frequency characterization required Alien crosstalk limits and test methods required Strategies
More informationGT Micro D High Speed Characterization Report For Differential Data Applications. Micro-D High Speed Characterization Report
GT-14-19 Micro D For Differential Data Applications GMR7580-9S1BXX PCB Mount MWDM2L-9P-XXX-XX Cable Mount Revision History Rev Date Approved Description A 4/10/2014 C. Parsons/D. Armani Initial Release
More informationISO/IEC 11801: (E)
ISO/IEC 11801:2002-09 (E) Information technology_- Generic cabling for customer premises CONTENTS FOREWORD...10 INTRODUCTION...11 1 Scope...13 2 Normative references...13 3 Definitions, abbreviations and
More informationSECTION TELECOMMUNICATIONS TESTING AND DOCUMENTATION
SECTION 17045 TELECOMMUNICATIONS TESTING AND DOCUMENTATION PART 1 - GENERAL 1.1 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including Facilities Management Design and Construction
More informationField-testing procedure of. LANmark-6 10G. Cabling System. Technical Paper Nexans Cabling Solutions June Revision 1.4
Field-testing procedure of LANmark-6 10G Cabling System Technical Paper Nexans Cabling Solutions June 2007 - Revision 1.4 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent
More informationISO/IEC SC25 WG3. Who are they & what can they do for 802.3cg? Alan Flatman. Principal Consultant LAN Technologies.
1 ISO/IEC SC25 WG3 Who are they & what can they do for 802.3cg? Alan Flatman Principal Consultant LAN Technologies Email: a_flatman@tiscali.co.uk 2 Who are ISO/IEC SC25 WG3? Ø International systems group
More informationWhite paper. Field Testing of Direct Attach Modified Permanent Links. occfiber.com
The dramatic growth of high-bandwidth wireless access points and other IP-enabled devices, such as surveillance cameras and building automation equipment has resulted in the practice of installing direct
More informationStandards Update. by Paul Kish NORDX/CDT
Standards Update by Paul Kish NORDX/CDT Standards overview Category 5e cabling new transmission parameters patch cord return loss Category 6 cabling cable choices backwards compatibility Summary Outline
More informationAS/NZS 3080:2003 AS/NZS
AS/NZS 3080:2013 (ISO/IEC 11801:2011, MOD) Incorporating Amendment No. 1 Australian/New Zealand Standard Information technology Generic cabling for customer premises Superseding AS/NZS 3080:2003 AS/NZS
More informationKeysight MOI for USB 2.0 Connectors & Cable Assemblies Compliance Tests
Revision 1.10 October 18, 2016 Universal Serial Bus Specification Revision 2.0 Keysight Method of Implementation (MOI) for USB 2.0 Connectors and Cables Assemblies Compliance Tests Using Keysight E5071C
More informationMosaic TM LCS2 Cat. 6A STP RJ 45 socket
870 LIMOGES Cedex Telephone: + 33 0 5 55 06 87 87 - Fax: + 33 0 5 55 06 88 88 Mosaic TM LCS2 Page 765 73 794 76 1. General characteristics...1 2. Presentation...1 3. Installation....1 4. Technical characteristics....2
More informationCOUPLING / DECOUPLING NETWORK (CDN) FOR UNSCREENED BALANCED PAIRS
IEC / EN 61000-4-6 specifies the design and performance of a range of coupling / decoupling networks (CDNs). Each CDN is specific to the type of cable and the intended signal carried on the cable. Teseq
More informationCorrigendum 1 to Amendment 2 1 ISO/IEC ISO/IEC (second edition 2002) Information technology Generic cabling for customer premises
Corrigendum 1 to Amendment 2 1 ISO/IEC 11801 ISO/IEC 11801 (second edition 2002) Information technology Generic cabling for customer premises Amendment 2 (2010) CORRIGENDUM 1 Corrigendum 1 applies to Amendment
More informationSeries 3402 lightning EMP protectors Gas discharge tube (GDT) technology up to 2.5 GHz
lightning EMP protectors Gas discharge tube (GDT) technology up to 2.5 GHz Description HUBER+SUHNER gas discharge tube protectors make the best of the traditional spark gap protection principle for general
More informationSCOPE OF ACCREDITATION TO ISO/IEC 17025:2005
SCOPE OF ACCREDITATION TO ISO/IEC 17025:2005 INTERTEK TESTING SERVICES NA INC. 3933 U.S. Route 11 Cortland, NY 13045 Terence O Beirne Phone: 607 758 6316 www.intertek.com ELECTRICAL Valid To: March 31,
More information/June/2014 Rev C
Qualification Test Report 501-93032 18/June/2014 Rev C AMP-TWIST Series Jacks for Class EA systems 1. INTRODUCTION 1.1 Purpose Qualification testing on AMP-TWIST* Series Jacks for Class EA Systems, to
More informationISO/IEC TR Guidance on 40GBASE-T T Cabling
1 ISO/IEC TR 11801-99 99-1 Guidance on 40GBASE-T T Cabling - a tutorial - Alan Flatman Principal Consultant LAN Technologies Email: a_flatman@tiscali.co.uk 2 Content 1. introduction to ISO/IEC SC25 WG3
More informationArtisan Technology Group is your source for quality new and certified-used/pre-owned equipment
Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED
More informationLANmark-6 10G LANmark-6 A
Field-testing procedure of LANmark-6 10G LANmark-6 A Cabling System Technical Paper Nexans Cabling Solutions March 2006 - Revision 1.1 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction
More informationPCS PATCH CORD SOLUTIONS PATCH CORD SOLUTIONS
Structured Cabling Solutions PCS PATCH CORDS. HiPerlink 6 Colored Patch Cords- 35,36 HiPerlink 1000 Category 5e Colored Patch Cords- 35,36 Snap-in Icons 36 ScTP Category 5 Patch Cord 37 Category 5 Colored
More informationPerformance specification for the Fluke DSP Fluke Corporation
Performance specification for the Fluke Fluke Corporation 1. Summary This document contains the performance specifications in terms of requirements per draft TIA and IEC specifications. Since requirements
More informationL200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL
L200 LINE/SUM/MIKE AMPLIFIER OPERATING AND MAINTENANCE MANUAL Copyright 1997-2005, Audio Technologies Incorporated - Printed in USA DESCRIPTION Your L200 Dual Line/Buffer Amplifier is an inexpensive, high
More informationDatasheet: DSX CableAnalyzer Series
Datasheet: DSX CableAnalyzer Series Datasheet: DSX CableAnalyzer Series The DSX CableAnalyzer Series is the copper certification solution of the Versiv cabling certification product family. The DSX Series
More informationCabling Infrastructure
Introduction Ethernet Banking on Structured Cabling Technology Drivers Classification of Cables Fibre-optic cable Cables in building Cabling Infrastructure Cabling systems address the networking requirements
More informationSolution. GigaSPEED SYSTIMAX. Evolutionary Design, Revolutionary Performance
SYSTIMAX GigaSPEED Solution Evolutionary Design, Revolutionary Performance A Proven Structured Connectivity Solution With Gigabit Power and Performance You re planning for the long run. And you can t afford
More informationNetwork Connectivity. Copper LAN cables. Product catalogue 2010
Product catalogue 2010 . Part of a total solution. The Schneider Electric copper LAN cables are an important part of our total Network Connectivity solution that also includes panels, cabinets, connectors
More informationWP100 Platform. control systems. CPU module for small and medium sized wind turbines. Safe operation in harsh environments
CPU module for small and medium sized wind turbines Safe operation in harsh environments Maintenance free - no fans and no batteries that need replacement Advanced event based data logging and storage
More information9/27/04 cci Cablecom Inc. 1
cci Cablecom Inc. 1 CCI Cablecom Inc. is a privately held, women owned corporation headquartered in Aurora, CO. We manufacture a variety of voice and datacom products. Cable applications Include: Local
More informationUSER MANUAL MODEL 570/ Base-T (CAT-5) Surge Protectors SALES OFFICE (301) TECHNICAL SUPPORT (301)
USER MANUAL MODEL 570/580 100Base-T (CAT-5) Surge Protectors Part# 07M570/580-B Doc# 074091UB Revised 2/16/96 SALES OFFICE (301) 975-1000 TECHNICAL SUPPORT (301) 975-1007 1.0 WARRANTY INFORMATION Patton
More informationNetwork Media and Layer 1 Functionality
Network Media and Layer 1 Functionality BSAD 146 Dave Novak Dean, Chapter 3, pp 93-124 Objectives Introduction to transmission media Basic cabling Coaxial Twisted pair Optical fiber Basic wireless (NIC)
More information40GBASE-T Cabling channel MDI-to-MDI
40GBASE-T Cabling channel MDI-to-MDI Chris DiMinico MC Communications/ Panduit cdiminico@ieee.org 1 802.3bq (NGBASE-T) Channel Modeling Ad Hoc 802.3bq 40GBASE-T Channel Modeling Ad Hoc initiated May Interim
More information40 Gigabit over copper - Thorsten Punke Marketing Manager ANZ TE Connectivity
40 Gigabit over copper - 40GBase-T Thorsten Punke Marketing Manager ANZ TE Connectivity IEEE 802.3 Ethernet Update 40GBase-T The history The technical truth The technical history More speed equals to more
More informationRun lots of CAT5 and CAT5e cable to support different high-speed applications and know at a glance which cable is for which purpose.
2007. All rights reserved. Black Corporation. FREE 24-hour Tech Support: 724-746-5500 blackbox.com CAT5/CAT5e Shielded and Unshielded Cables Run lots of CAT5 and CAT5e cable to support different high-speed
More informationINTERNATIONAL STANDARD
INTERNATIONAL TANDARD IEC 9- First edition 00-0 Generic cabling systems pecification for the testing of balanced communication cabling in accordance with IO/IEC 0 Part : Patch cords and work area cords
More informationinsilco. intelligent networking. insilco. intelligent networking
insilco intelligent networking 04-07 - 2017 insilco intelligent networking 28-10 - 2016 Contents Intelligent Network Management System 01 Network Scanner 02 Smart Patch Panels 03 Smart Patch Cords, Flat
More informationJamey Calloway, RCDD Product Management Specialist Optical Cable Corporation
Testing and deployment of direct attach and the impact of category 8 Thursday, 10 August 2017, 3:50-4:40 P.M. Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Overview Traditional
More informationGE Fanuc IC694ALG221. Rx3i PacSystem
GE Fanuc IC694ALG221 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic694alg221 Rx3i PacSystem Input module, analog 4 point current. IC694A IC694AL IC694ALG 919-535-3180 sales@pdfsupply.com
More informationSupplement. Manual Title: DSP-4000 Series User Supplement Issue: 3 Print Date: July 2001 Issue Date: 10/02 Revision/Date: Page Count: 4
Established 1981 Advanced Test Equipment Rentals www.atecorp.com 800-404-ATEC (2832) Supplement Manual Title: DSP-4000 Series User Supplement Issue: 3 Print Date: July 2001 Issue Date: 10/02 Revision/Date:
More informationHiLo V2 Interface Board User Guide
HiLo V2 Interface Board User Guide Table of Content 1. Revision History 2. Function description of all key components 3. More detail description External document URD1 OTL 5635.2 011 72396 ed 01 25 January
More informationEthernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement
Ethernet and PoE Operation Over Single Pair Twisted-Pair Copper Cabling (SPE) Chris DiMinico AEM Technical Sales Test and Measurement Overview SPE is poised to enable a new class of low power devices that
More informationINTERNATIONAL STANDARD
INTERNATIONAL STANDARD ISO/IEC 14709-2 First edition 1998-05 Information technology Configuration of Customer Premises Cabling (CPC) for applications Part 2: Integrated Services Digital Network (ISDN)
More informationThe High Cost of a Low-Cost Cable Certification Tester
The High Cost of a Low-Cost Cable Certification Tester Our thanks to Fluke Networks for allowing us to reprint the following article. How much does it cost? That is typically the first question a cabling
More informationField-testing procedure. LANmark-6
Field-testing procedure LANmark-6 Technical Paper Nexans Cabling Solutions September 2006 Table of Contents 1 Introduction 3 2 How to proceed? 4 2.1 Introduction 4 2.2 Permanent link testing vs. Channel
More informationHow new testing standards affect you Singapore, Nov 2009
How new testing standards affect you Singapore, Nov 2009 Adrian Young Sr. Customer Support Engineer In this presentation, we will cover How ANSI/TIA-568-C.2 has consolidated all the different test plugs
More informationISO/IEC Edition INFORMATION TECHNOLOGY GENERIC CABLING FOR CUSTOMER PREMISES. Part 1: General requirements CORRIGENDUM 1
ISO/IEC 11801-1:2017/COR1:2018 1 ISO/IEC 11801-1 Edition 1.0 2017-11 INFORMATION TECHNOLOGY GENERIC CABLING FOR CUSTOMER PREMISES Part 1: General requirements CORRIGENDUM 1 Foreword Replace, in list item
More informationSMA Series. Specification. Description. Applications Civil & Military Telecommunication Instrumentation SMA SMA. Interface Mating Dimensions
Series Specification 50 ohm 0-18 GHZ connectors are adaptable to interconnection requirements of both systems and components. S-Conn offers a wide variety of cable connectors, receptacles, feed thrus,
More informationIEC INTERNATIONAL ISO/IEC STANDARD ISO. Information technology Configuration of Customer Premises Cabling (CPC) for applications
INTERNATIONAL ISO/IEC STANDARD 14709-1 First edition 1997-09-01 Information technology Configuration of Customer Premises Cabling (CPC) for applications Part 1: Integrated Services Digital Network (ISDN)
More informationCable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.
Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications Broadband High-Speed LAN Voice Robert Y. Faber Jr., RCDD/NTS Minimum Port Recommendations TIA/EIA-568-B.1 2 outlets
More informationProduct information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361
Product information 19" 3U Global Patch Panel 48xRJ45/u, Cat. 6, partly populated R302361 1 Pcs. 19" 3U Global patch panel/u incl. cable tie shelf 12 connection module holders Global/u 3 Global blind covers
More informationVersatile, Automatic RCL Meters
Versatile, Automatic RCL Meters Technical Specifications PM 6306 / PM 6304 / PM 6303A PM 6306 and PM 6304 Versatile component measurement and testing Easy to use, at-a-glance display Test frequencies,
More informationProduct information Patch Cord Cat. 5e, U/UTP, 4P, PVC, gray, RJ45/u- RJ45/u, 0.5 m
Product information Patch Cord, U/UTP, 4P, PVC, gray, RJ45/u- RJ45/u, 0.5 m R305014 101336005 10 Pcs. Cable identification: U/UTP Outer jacket: PVC Conductor diameter copper strand: AWG 26/7 Screened in
More information