1 GelDoc-It TS2 & ChemiDoc-It TS2 Imagers Installation and User Instructions UVP, LLC Ultra-Violet Products Ltd W. 11th Street Unit 1, Trinity Hall Farm Estate Upland, CA Nuffield Road, Cambridge CB4 1TG UK Phone: (800) Phone: +44(0) Fax: (909) Fax: +44(0) Web Site: Rev A

2 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 2 Table of Contents Introduction... 3 System Components... 4 Optional Equipment... 7 Setup Instructions... 9 Components... 9 Installing Emission Filters Using the System Powering Up the System Operating the TS2 Software Interface Selecting Emission Filters Using the Transilluminator Using the Overhead (Epi) Lighting Using the UV Gel Viewer Window Image Focusing Service Procedures Return Procedure Replacement Parts and Accessories Troubleshooting Technical Support Warranty... 15

3 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 3 Introduction The GelDoc-It TS2 Imager is a high resolution imager capable of capturing, documenting and analyzing fluorescent gel images. In addition to gel documentation capabilities, the ChemiDoc-It TS2 Imager is equipped with a cooled, scientific-grade CCD camera allowing users to capture, document and analyze chemiluminescent blot images, including Western blots. The GelDoc-It TS2 and ChemiDoc-It TS2 are self-contained imaging systems with a built-in 15.6 touch screen and computer. Additionally, the systems incorporate a light-tight darkroom with TS2 Software for image acquisition. The darkroom has a UV-blocking gel viewer window, built-in overhead epi white lighting, a UV transilluminator and a five-position slide-out emission filter wheel with an ethidium bromide (EtBr) emission filter included as standard. Save images to the internal hard drive, to an external USB storage device or to a network drive for later quantitative analysis or enhancement for publication.

4 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 4 System Components Refer to the packing slip and pictured components for specific parts and components included with the system LCD Touch Screen with Built-In Computer Five Position Slide- Out Emission Filter Wheel Main Power Button Built-In Overhead White Lights UV Safety Interlock Switch & Override Black Chemi Tray Transilluminator on Roll-Out Tray Stylus with Adhesive Holder (Not Shown) Power Indicator Lights Camera and Lens Built Into Darkroom Hood BioLite Access Port USB and SD Card Access Port Wide Access Door UV Gel Viewer Window

5 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 5 Specifications Power Requirements: 100/115V, 50/60Hz; 3.1 Amps at 120 Volts 230V, 50/60Hz; 1.55 Amps at 230 Volts Mains supply voltage fluctuations are not to exceed 10 percent of the nominal supply voltage Pollution Degree: 2 Installation Category: Altitude: II Up to 2000m Ambient Temperature: 5 C to 40 C Humidity: Maximum relative humidity of 80% for temperatures up to 31 C, decreasing linearly to 50% maximum relative humidity at 40 C Built-In Touch Screen Computer Operating System: Connectivity Ports: Wireless Networking Capability: USB Flash Drive Capacity: Internal Hard Drive: Software: Windows 7, 64-Bit 2 USB, 1 SD/SDHC/MMC (side of system) 4 USB, VGA and Ethernet (rear of system) b/g/n 2 GB (minimum) 250 GB (minimum) TS2 (Touch Screen) Software (supplied with all systems) VisionWorks LS Software (supplied with ChemiDoc-It TS2 only) Cameras and Lenses GelDoc-It TS2 : The GelDoc-It TS2 is equipped with the GelCam 310 camera, a scientific-grade monochrome CCD camera with a resolution of 2.0MP (1600x1200). The GelCam 310 is equipped with a mm f/1.2 zoom lens. ChemiDoc-It TS2 : The ChemiDoc-It TS2 is equipped with either the Chemi 415 or MegaCam 810 scientific-grade monochrome CCD camera. Both cameras are Peltier cooled and offer full 16-bit file bit depth: The Chemi 415 camera is a 1.4MP unit (1360x1024) with Peltier cooling to 35 C below ambient. The Chemi 415 has a peak quantum efficiency of 62% and is capable of binning from 1x1 to 8x8. This camera is equipped with a mm f/1.2 zoom lens. The MegaCam 810 camera is an 8.1 MP camera (3296x2472) with Peltier cooling to 35 C below ambient. The MegaCam 810 has a peak quantum efficiency of 50% and is also capable of binning from 1x1 to 8x8. This camera is equipped with either a 50mm f/1.2 lens or a 30mm f/1.4 lens, both of which have a fixed focal length (non-zoom capable). All camera settings are factory pre-set for optimum performance when viewing gels, films or membranes under low light level conditions. Contact UVP Technical Support prior to making any adjustments to the camera settings. Ethidium Bromide (EtBr) Emission Filter The ethidium bromide (50mm 2 ) UV-blocking bandpass interference filter blocks UV and IR radiation emitted from the transilluminator. The filter is placed in the slide-out filter wheel assembly on the side of the Imager. The filter allows visualization of fluorophores from nm, targeting the ethidium bromide emission peak of 605nm.

6 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 6 Additional filters are available for other specific fluorophores, including custom filters. Filters can also be removed when imaging non-fluorescent media (including chemiluminescent blots, protein gels, colony plates, etc.) in order to produce brighter images. Contact UVP for ordering information. Darkroom The darkroom is light tight to provide optimal imaging conditions. Darkroom features include: Epi (overhead) LED white light Roll-out transilluminator tray UV-safe gel viewer window built into the darkroom door Five position emission filter wheel Brackets and built-in power ports for installing optional epi UV illumination lamps Brackets for installing optional high-intensity halogen or xenon BioLite epi light guides Built-in power port for transilluminator Power cord for optional LED White Light Plate UV safety interlock switch with manual override to disable UV transillumination and optional UV epi illumination when darkroom door is opened Transilluminator The GelDoc-It TS2 and ChemiDoc-It TS2 Imagers can accommodate UVP s Benchtop and FirstLight transilluminator models. UVP offers a variety of transilluminator configurations, including Benchtop models with multiple wavelengths and variable intensities as well as the highly uniform, patented FirstLight transilluminator. Refer to the packing slip for the transilluminator included with your system. Note: For UV protection and to extend the life of the UV transilluminator, the system incorporates a customizable transilluminator shutoff timer built into the software. For additional information, refer to the TS2 Software User Manual included with the system or available online at LCD Touch Screen The GelDoc-It TS2 and ChemiDoc-It TS2 Imagers contain a fully integrated 15.6-inch color touch screen. The touch screen allows the user to perform a variety of tasks, including previewing, capturing, saving and printing images, as well as selecting preference options, without the use of an external mouse or keyboard. The screen can be pressed by finger or with the included pen-shaped stylus. For users who prefer not to use the touch screen interface, an external keyboard and mouse are included as standard. These components can be plugged into any available system USB port. TS2 Software Image analysis and hardware functions for the GelDoc-It TS2 and ChemiDoc-It TS2 Imagers are controlled by the TS2 (Touch Screen) Software interface. In addition to image preview, capture and save functions, the TS2 Software controls camera and lens functions (exposure, aperture, focus and zoom), image printing, lighting and filter selection, and other user preferences. For additional information, refer to the TS2 Software User Manual included with the system or available online at TS2 Software Screen Fluorescent Focus Target The UVP Fluorescent Focus Target fluoresces when placed on a UV transilluminator or when exposed to overhead UV. The Target provides sharp fluorescent images to aid in adjusting the lens and camera settings for ideal imaging results. Fluorescent Focus Target

7 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 7 Optional Equipment UVP offers a variety of optional equipment to support the needs of varying laboratory environments. Refer to Replacement Parts and Accessories at the end of this manual for optional equipment part numbers. Thermal Printer The thermal printer provides archive quality, 256 grayscale prints and five optional cost-effective print sizes. Thermal Printer UV Handheld Lamps for Epi (Overhead) Lighting A set of two 4-watt ultraviolet lamps can be connected inside the darkroom to provide epi UV illumination. These lamps can be switched on or off in the Lighting and Filters menu within the TS2 Software and can also be removed from the darkroom and used as standalone handheld lamps (as seen in the image to the right). UV Lamp LED White Light Plate The LED White Light Plate emits high uniformity with less than 5% coefficient of variance (CV). Plug the LED White Light Plate directly into the power supply within the system darkroom and select White Light under the Lighting and Filters menu within the TS2 Software. LED White Light Plate Converter Plates An alternate to the LED White Light Plate, the UV/White Converter Plate allows imaging of non-fluorescent stained media with an ultraviolet transilluminator. The converter plate is specially coated to convert 302nm UV output to white light rather than using a separate white light box or plate. The Visi-Blue Converter Plate (not shown) converts UV to a safe nm wavelength designed for use with blue excitation samples and SYBR Green, SYPRO Orange and GFP stains. UV/White Converter Plate

8 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 8 VisionWorks LS Analysis Software The GelDoc-It TS2 can be configured with VisionWorksLS Software for analysis of gels, plates and membranes. The software features image enhancement, complete analysis tools and reporting capabilities, and is ideal for users who require image analysis functions in addition to the standard image acquisition capabilities of the GelDoc-It TS2. NOTE: VisionWorksLS is included as standard with the ChemiDoc-It TS2.

9 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 9 Setup Instructions Components When unpacking the GelDoc-It TS2 and ChemiDoc-It TS2, the following items will be included: 1. GelDoc-It TS2 or ChemiDoc-It TS2 darkroom 2. Ethidium bromide (EtBr) emission filter 3. Transilluminator 4. Power cable 5. Keyboard and mouse 6. VisionWorksLS Software (included with ChemiDoc-It TS2 only) 7. Supporting documentation When unpacking and setting up the darkroom, two people are required to move the darkroom. Place the darkroom on a flat surface which can provide adequate support for up to 100 pounds. WARNING: Do not attempt to perform any setup procedures while the system is plugged in or powered on unless otherwise instructed. CAUTION: Do not install the system in areas with high moisture, dust or high temperatures. Keep the equipment away from motors or any other large magnetic equipment apparatus. This system is designed for indoor use only. Connecting the Power Cables 1. Plug the main power cable into the back of the darkroom and the other end into a surgeprotected power outlet. Note: It is recommended to leave the power switch on the back of the system in the ON position except when the system will not be used for an extended period of time (one day or longer). Note: Do not position the system so that it is difficult to access the power cable and operate the main power switch at the back of the unit. 2. Inside the darkroom, place the transilluminator on the roll-out tray. Connect the transilluminator to the internal power jumper cable. 3. If installing the LED White Light Plate, place the plate on top of the UV transilluminator and connect the power cord coming from inside the darkroom to the back of the Plate. 4. If installing epi UV handheld lamps, place the lamps in the brackets located at the top of the darkroom. Plug the handheld lamps into the outlets provided inside the darkroom. Place the power switches located on the outside of the handheld lamps in the ON position.

10 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 10 Installing Emission Filters To install the 50mm 2 ethidium bromide (EtBr) filter and any other emission filters: 1. Carefully remove the filter from the protective plastic case, holding the filter at the edges to prevent placing fingerprints on the glass surface. 2. The filter wheel is located on the user s right side of the darkroom. Press in on the slide-out filter wheel door and the door will pop out slightly. Pull the filter wheel assembly out until it stops. Slide-Out Filter Wheel Door 3. Manually rotate the filter wheel to the desired position. Place the included ethidium bromide filter in Position #1. NOTE: Before placing the filter in the filter wheel, ensure that the text on the edge of the filter is positioned so it is right side up when facing the installer. 4. Note the position of all installed filters for entry into the Lighting and Filters menu in the TS2 Software (refer to the TS2 Software User Manual for more information). 5. Once all filters have been loaded, slide the filter wheel assembly back into the system. Press the filter wheel assembly door until the assembly locks into place. Additional and replacement emission filters are available through UVP. Refer to the Replacement Parts and Accessories section of this manual for ordering information.

11 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 11 Using the System Powering Up the System Set the black power switch on the back of the system to the ON (I) position. Once plugged in to a wall outlet and the black power switch on the back of the system is placed in the ON (I) position, the GelDoc- It TS2 and ChemiDoc-It TS2 systems are always powered on. Press the POWER button on the front of the system to power on the internal computer/touch screen and access controls for the camera, lenses, lighting and other functions. Power Indicator Lights The Power Indicator Lights on the front of the unit indicate when the system s main power and ultraviolet illumination are on. Main Power will illuminate green when the black main power switch on the back of the unit is in the ON (I) position (this does not indicate that the internal computer or touch screen are on). Ultraviolet On will illuminate red when ultraviolet illumination is Power Button active within the darkroom. The POWER button will illuminate blue when the internal computer and touch screen are on. (Note: The black main power switch on the back of the unit must be in the ON (I) position in order for the internal computer and touch screen to function.) Note: It is recommended to leave the power switch on the back of the system in the ON position except when the system will not be used for an extended period of time (one day or longer). Operating the TS2 Software Interface Upon startup, the internal computer will proceed through the boot-up process. When complete, the screen will display the Windows desktop. The TS2 Software screen, similar to the one below, will automatically open shortly thereafter: To exit the TS2 Software interface, press either the close (X) or minimize (_) buttons at the top right corner of the software (see red circle above). To power down the system, exit the TS2 Software interface by

12 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 12 pressing either the close (X) or minimize (_) buttons at the top right of the software. Then, using the Windows Start menu, select Shut Down. Refer to the TS2 Software User Manual for further instructions on using the software. Selecting Emission Filters See the Installing Emission Filters section of this manual for instructions on installing individual emission filters. Once all filters have been installed, select the Lighting and Filters menu in the TS2 Software and click the Reset Wheel button under the Filters tab to realign and calibrate the filter wheel within the system. Using the Transilluminator To use the UV transilluminator or LED White Light Plate, ensure that the components are plugged into the system (see the Connecting the Power Cables section of this manual for more information). Using the Lighting and Filters menu in the TS2 Software, select either UV or White Light Plate depending upon the application. When using the UV transilluminator, ensure that the green power switch on the front of the transilluminator unit is in the ON position. NOTE: For UV protection and to extend the life of the UV transilluminator, the system incorporates a customizable transilluminator shutoff timer built into the software. For additional information, refer to the TS2 Software User Manual included with the system or available online at Using the Overhead (Epi) Lighting To operate the built-in overhead white light, use the Lighting and Filters menu in the TS2 Software and select White under Epi Illumination. To operate the optional overhead (epi) UV illumination, ensure that the optional UV handheld lamps are plugged into the back of the darkroom interior and are mounted to the brackets at the top of the darkroom. Also ensure that the power switches, located on the handheld lamps, are in the ON position. To provide power to the handheld lamps, use the Lighting and Filters menu in the TS2 Software and select Accessory under Epi Illumination. Using the UV Gel Viewer Window The UV Gel Viewer Window, built into the darkroom door, allows users to view the interior of the darkroom without opening the darkroom door. To open the Window, press firmly on the top of the Window cover to release the pressure-sensitive clasp and open the viewer. The Window glass is UV blocking while providing a clear view to the transilluminator surface for sample viewing without opening the darkroom door. NOTE: Close the UV Gel Viewer Window prior to capturing a light-sensitive image such as a chemiluminescent blot. Image Focusing Prior to capturing an image, prepare the image focus: 1. Turn on the transilluminator and place the Fluorescent Focus Target (see the Fluorescent Focus Target section of this manual for more information) on the transilluminator surface. NOTE: The darkroom has a UV safety switch that turns off the transilluminator and optional UV handheld lamps when the door is open. 2. Using the TS2 Software, click to turn ON the Live Preview. Adjust the exposure, aperture, zoom (if applicable) and focus controls on the bottom portion of the TS2 Software screen until an ideal image is visible.

13 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 13 Service Procedures Return Procedure A Returned Goods Authorization (RGA) number must be obtained from UVP Customer Service before returning any product. Replacement Parts and Accessories To order accessories or replacement parts for the GelDoc-It TS2 and ChemiDoc-It TS2 Imagers, contact UVP s offices. Part Description UV Handheld Lamps: UV Handheld Lamp, 254/365nm, 4 watt (115V) UV Handheld Lamp, 254/365nm, 4 watt (230V) Part Number (2 Recommended) (2 Recommended) Fuses: Fuse, 3.15A (for Darkroom) Fuse, 2A (for Transilluminators) (2 Recommended) (2 Recommended) Emission Filters: Filter, Ethidium Bromide, 50mm Square Filter, SYBR Green, 50mm Square Filter, SYBR Gold, 50mm Square Transillumination Accessories: LED White Light Plate White Light Converter Plate, 21x26cm Visi-Blue Converter Plate, 21x26cm Gel Accessories: Gel-Cutter Gel-Ruler Gel-Scooper Gel-Tray, small Gel-Sentry DNA Preparation Plate Fluorescent Standard Step Tablet Protective Equipment: Spectacles, UV Blocking (UVC-303) Goggles, UV Blocking (UVC-503) Faceshield, UV Blocking (UVC-803) Troubleshooting No Power to the Darkroom or Transilluminator 1. Recheck the main power cord connection to the GelDoc-It TS2 /ChemiDoc-It TS2 darkroom as well as the power cables between the darkroom and transilluminator, LED White Light Plate or optional UV handheld lamps. 2. Check the fuses located at the back of the unit next to the power port. A small flat-head screwdriver or similar tool will be required. Push the bottom tab of the fuseholder up until the fuseholder s bottom pops out. Then, push the top tab down until the top pops out. The entire fuseholder can now be pulled out.

14 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 14 Inspect the thin wire within each glass fuse to see if there is a break in the wire. If so, replace the fuse(s). If fuses are blowing repeatedly, contact UVP Technical Support for additional troubleshooting. Transilluminator Will Not Turn On 1. In addition to turning on UV transillumination in the Lighting and Filters menu within the TS2 Software, the transilluminator itself has a power switch. Make sure that the green transilluminator power switch, located on the front of the transilluminator, is in the ON position. 2. For UV protection and to extend the life of the UV transilluminator, the system incorporates a customizable transilluminator shutoff timer built into the software. For additional information, refer to the TS2 Software User Manual included with the system or available online at Error Messages Appear on the Screen Care and Cleaning 1. An error message that is related to the TS2 software interface or Microsoft Windows may appear on the screen. If the message is related to Microsoft Windows, such as a reminder to activate or update the copy of Windows, please contact your system administrator for assistance. 2. If an error message appears repeatedly and your system administrator does not recognize it as a Microsoft Windows error, contact UVP Technical Support for further assistance. Use only mild soap or detergent solution for cleaning. Do NOT use oil- or petroleum-based cleaners for the cabinet. Ensure that the system is turned OFF and unplugged during cleaning. Technical Support UVP offers free lifetime technical support on all of its products and software. Should you have any questions regarding the product s use, operation or repair, contact UVP s offices at the locations below, or visit If you are in North America, South America, East Asia or Australia: Call (800) or (909) , and ask for Customer Service during regular business days, between 7:00 am and 5:00 pm, PST. your message to: info@uvp.com Fax Customer Service, and send it to (909) Write to: UVP, LLC 2066 W. 11 th Street, Upland, CA USA If you are in Europe, Africa, the Middle East of Western Asia: Call +44(0) , and ask for Customer Service during regular business days between 9:00 am and 5:30 pm. your message to: uvp@uvp.co.uk Fax Customer Service, and send it to: +44(0) Write to: Ultra-Violet Products Ltd Unit 1, Trinity Hall Farm Estate, Nuffield Road, Cambridge CB4 1TG UK

15 GelDoc-It TS2 and ChemiDoc-It TS2 Imagers 15 Warranty UVP's products are guaranteed to be free of defects in materials, workmanship and manufacture for one (1) year from date of purchase. Consumable and disposable parts including, but not limited to tubes and filters, are guaranteed to be free from defects in manufacture and materials for ninety (90) days from date of purchase. Transilluminators carry a two (2) year warranty from date of purchase. If equipment failure or malfunction occurs during the warranty period, UVP shall examine the inoperative equipment and have the option of repairing or replacing any part(s) which, in the judgment of UVP, were originally defective or became so under conditions of normal usage and service. No warranty shall apply to this instrument, or part thereof, that has been subject to accident, negligence, alteration, abuse or misuse by the end-user. Moreover, UVP makes no warranties whatsoever with respect to parts not supplied by UVP or that have been installed, used and/or serviced other than in strict compliance with instructions appearing in this manual. In no event shall UVP be responsible to the end-user for any incidental or consequential damages, whether foreseeable or not, including but not limited to property damage, inability to use equipment, lost business, lost profits, or inconvenience arising out of or connected with the use of instruments produced by UVP. Nor is UVP liable or responsible for any personal injuries occurring as a result of the use, installation and/or servicing of equipment. This warranty does not supersede any statutory rights that may be available in certain countries. GelDoc-It, ChemiDoc-It, VisionWorks and FirstLight are registered trademarks of UVP, LLC. BioLite is a trademark of UVP, LLC.

GelMax Imager. Installation and User Instructions

GelMax Imager. Installation and User Instructions GelMax Imager Installation and User Instructions UVP, LLC Ultra-Violet Products Ltd. 2066 W. 11th Street Unit 1, Trinity Hall Farm Estate Upland, CA 91786 Nuffield Road, Cambridge CB4 1TG UK Phone: (800)

More information

GelDoc-It 2 & ChemiDoc-It 2 Imagers

GelDoc-It 2 & ChemiDoc-It 2 Imagers GelDoc-It 2 & ChemiDoc-It 2 Imagers Installation and User Instructions UVP, LLC Ultra-Violet Products Ltd. 2066 W. 11th Street Unit 1, Trinity Hall Farm Estate Upland, CA 91786 Nuffield Road, Cambridge

More information

BioDoc-It and VisiDoc-It Imaging Systems

BioDoc-It and VisiDoc-It Imaging Systems BioDoc-It and VisiDoc-It Imaging Systems Installation and User Instructions BioDoc-It Imaging System VisiDoc-It Imaging Systems UVP, LLC Ultra-Violet Products Ltd. 2066 W. 11th Street Unit 1, Trinity Hall

More information

MultiDoc-It Imaging System

MultiDoc-It Imaging System MultiDoc-It Imaging System Installation and User Instructions UVP, LLC Ultra-Violet Products Ltd. 2066 W. 11th Street Unit 1, Trinity Hall Farm Estate Upland, CA 91786 Nuffield Road, Cambridge CB4 1TG

More information

ChromaDoc-It Imaging System

ChromaDoc-It Imaging System ChromaDoc-It Imaging System Installation and User Instructions UVP, LLC Ultra-Violet Products Ltd. 2066 W. 11th Street Unit 1, Trinity Hall Farm Estate Upland, CA 91786 Nuffield Road, Cambridge CB4 1TG

More information

MultiDoc-It Imaging System

MultiDoc-It Imaging System MultiDoc-It Imaging System Installation and User Instructions UVP, LLC Ultra-Violet Products Ltd. 2066 W. 11th Street Unit 1, Trinity Hall Farm Estate Upland, CA 91786 Nuffield Road, Cambridge CB4 1TG

More information

MultiDoc-It Imaging Systems

MultiDoc-It Imaging Systems MultiDoc-It Imaging Systems Installation and User Instructions UVP, LLC Ultra-Violet Products Ltd. 2066 W. 11th Street Unit 1, Trinity Hall Farm Estate Upland, CA 91786 Nuffield Road, Cambridge CB4 1TG

More information

BioSpectrum Imaging System

BioSpectrum Imaging System BioSpectrum Imaging System Instruction Guide UVP, LLC 2066 W. 11th Street, Upland, CA 91786 Tel: (909) 946-3197 / (800) 452-6788 Fax: (909) 946-3597 Web Site: www.uvp.com Ultra-Violet Products Ltd. Unit

More information

Manual BioSpectrum Imaging System

Manual BioSpectrum Imaging System Manual BioSpectrum Imaging System Instruction Guide UVP, LLC 2066 W. 11th Street, Upland, CA 91786 Tel: (909) 946-3197 / (800) 452-6788 Fax: (909) 946-3597 Web Site: www.uvp.com Ultra-Violet Products Ltd.

More information

Ultra-Violet Products Ltd W 11th Street, Upland, CA Unit 1,Trinity Hall Farm Estate,

Ultra-Violet Products Ltd W 11th Street, Upland, CA Unit 1,Trinity Hall Farm Estate, High Performance UV Transilluminators Instruction Manual UVP, LLC Ultra-Violet Products Ltd. 2066 W 11th Street, Upland, CA 91786 Unit 1,Trinity Hall Farm Estate, Tel: (800) 452-6788 / (909) 946-3197 Nuffield

More information

VisionWorks Acquisition and Analysis Software Quick Start Guide

VisionWorks Acquisition and Analysis Software Quick Start Guide VisionWorks Acquisition and Analysis Software Quick Start Guide UVP, LLC Ultra-Violet Products Ltd. 2066 W. 11 th Street Unit 1, Trinity Hall Estate, Nuffield Road Upland, CA 91786 Cambridge, CB4 1TG UK

More information

Contents Contents 2 Preface 3 Introduction 4 Components 5 Operation 6 Timer 7 Lamp Replacement 9 Specification 10 Ordering Information 11 2

Contents Contents 2 Preface 3 Introduction 4 Components 5 Operation 6 Timer 7 Lamp Replacement 9 Specification 10 Ordering Information 11 2 SPOT-LITE CURING SYSTEM USER S GUIDE http://www uvp com UVP, Inc Ultra-Violet Products Ltd 2066 W 11 th Street Unit 1, Trinity Hall Estate, Nuffield Road Upland, CA 91768 USA Cambridge, CB4 1TG, UK (800)

More information

MS Compact 1.4 & 2.0 Megapixel CCD Image System

MS Compact 1.4 & 2.0 Megapixel CCD Image System MS Compact 1.4 & 2.0 Megapixel CCD Image System MS Compact 1.4 & 2.0 Megapixel CCD Image System The UVCI140 & 200 series is the advanced CCD gel imaging system from Major Science. It consists of a CCD

More information

WiseDoc Gel Documentation System

WiseDoc Gel Documentation System WiseDoc Gel Documentation System User Manual (Version 1.3.1) written for Model WGD-30 DAIHAN Scientific, Co., Ltd. Features 1 Thank you for purchase of WiseDoc Gel Documentation Systems. For gel-documentation

More information

E-BOX SIMPLY PRECISE STAND-ALONE GEL IMAGING

E-BOX SIMPLY PRECISE STAND-ALONE GEL IMAGING E-BOX SIMPLY PRECISE STAND-ALONE GEL IMAGING HEADQUARTERS Vilber Lourmat BP-31 - ZAC de Lamirault - Collégien F-77601 Marne-la-Vallée cedex 3 France T.: +33 (0) 1 60 06 07 71 info@vilber.com GERMAN OFFICE

More information

E-BOX SIMPLY PRECISE STAND-ALONE GEL IMAGING

E-BOX SIMPLY PRECISE STAND-ALONE GEL IMAGING E-BOX SIMPLY PRECISE STAND-ALONE GEL IMAGING PADBOX SYSTEM OR BUILT-IN TRANSILLUMINATOR We offer two versions of the E-Box CX5: the transilluminator version and the PadBox version. The transilluminator

More information

SYNGENE PRODUCT GUIDE G

SYNGENE PRODUCT GUIDE G Syngene Europe and International Headquarters: Beacon House Nuffield Road Cambridge CB4 1TF UK Tel: +44 (0)1223 727123 Fax: +44 (0)1223 727101 email: sales@syngene.com Syngene USA Headquarters: 5103 Pegasus

More information

Chemlux Imager. Applications

Chemlux Imager. Applications Features: High Resolution and High Sensitivity of 6 M Cooled CCD Camera 16-bit, High Dynamic Range, up to 6 X 6 Bin Mode Three-level Movable Platform with Auto Focus Feature Adjustable RGB Light* Intensity

More information

Bio-Pyramid / STYLUS 1s MBP01-S1SB User s Manual

Bio-Pyramid / STYLUS 1s MBP01-S1SB User s Manual Bio-Pyramid / STYLUS 1s MBP01-S1SB User s Manual Standard Accessories 1) Olympus STYLUS 1s 2) Lithium ion battery (BLS-50) 3) Lithium ion charger (BCS-5) 4) Lithium ion charger cable 5) USB Cable (CB-USB6)

More information

MICRODOC Systems Instruction Manual. Model Numbers: -

MICRODOC Systems Instruction Manual. Model Numbers: - MICRODOC Systems Instruction Manual Model Numbers: - MICRODOC MICRODOC1D MDOCUV312 MDOCUV3121D MDOCUV254 MDOCUV2541D MDOCUV365 MDOCUV3651D MDOCUV254/312 MDOCUV254/3121D MDOCUV254/365 MDOCUV254/3651D MDOCBASIC

More information

Model : LUVDI/LUVDI-CB Please read this manual carefully before using the instrument Labnics Equipment

Model : LUVDI/LUVDI-CB Please read this manual carefully before using the instrument Labnics Equipment COMPACT DIGIMAGE SYSTEM Instruction Manual Model : LUVDI/LUVDI-CB Please read this manual carefully before using the instrument Labnics Equipment Table of Content Sr.No. Contents Pg. No. 1.1 Un packing

More information

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only.

Operation Manual. Concorde 600 Power Supply. *This instrument is intended for laboratory use only. Concorde 600 Power Supply Operation Manual Cat.no. R10-1001011 *This instrument is intended for laboratory use only http://www.recenttec.com E-mail : support@recenttec.com Version 1.1 Packing List x 1

More information

version BROCHURE Gel Documentation System

version BROCHURE Gel Documentation System version 1.0 2018 BROCHURE Gel Documentation System Imaging System NEW SmartView Pro Imager Standalone gel doc system with high-quality monochrome CCD Exchangeable emission filters provide for instant visualization

More information

EPS Power Supply

EPS Power Supply EPS - 600 Power Supply Installation and Operation Manual Version 1.0 *This instrument is intended for laboratory use only Index A. Important Notice ----------------------------------------------------------------

More information

Automated Tuner System Power Distribution Hub

Automated Tuner System Power Distribution Hub User Guide Automated Tuner System Power Distribution Hub Model MT1020B MT1020-340 (Rev B) 12/11 User Guide Automated Tuner System Power Distribution Hub Model MT1020B 2900 Inland Empire Boulevard Ontario,

More information

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C

Benchmark Plus Microplate Reader User Manual. This Instrument for Laboratory Use Only Rev C Benchmark Plus Microplate Reader User Manual This Instrument for Laboratory Use Only 4100172 Rev C 4100172 Rev C Benchmark Plus System with Incubator Catalog Number 170-6930 Benchmark Plus Reader with

More information

Ioline 300/350HF System

Ioline 300/350HF System Quick Start Guide Ioline 300/350HF System User Notice Trademarks Ioline is a trademark of Ioline Corporation. Other product names, logos, designs, titles, words or phrases mentioned within this publication

More information

Black Body Calibration Source User Manual

Black Body Calibration Source User Manual Black Body Calibration Source Surface Plate Type Models CBB13EC CBB14AC/KC CBB15GC CBB14AC CBB15GC CBB14KC Models: CBB13EC CBB14AC CBB14KC CBB15GC WD1068 October 18, 2013 Rev C 01/12/18 CBB13EC Wahl Instruments

More information

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631)

ACCU-SCOPE INC. 73 Mall Drive Commack, NY Phone: (631) Fax: (631) 3065 ZOOM STEREO MICROSCOPE SERIES INSTRUCTIONS ACCU-SCOPE INC. 73 Mall Drive Commack, NY 11725 Phone: (631) 864-1000 Fax: (631) 543-8900 E-mail: info@accu-scope.com www.accu-scope.com Head Locking Screw

More information

Installation Instructions

Installation Instructions Please read all instructions before installing SPECIFICATIONS RT-100 Time Switch Programmable Countdown Voltage...120VAC, 60HZ Load (Single Pole Circuit) Incandescent or fluorescent lamp... 0 600 Watt

More information

Start Here. All-in-One Printer. Print Copy Scan

Start Here. All-in-One Printer. Print Copy Scan Start Here All-in-One Printer Print Copy Scan Note: A USB 2.0 cable is required to connect your Kodak All-in-One printer to your Windows or Macintosh OS computer. Available in the Kodak online store or

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc.

Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc. Operational Manual Spectrophotometer Model: SP-830 PLUS Metertech Inc. Version 1.06 Metertech Inc. provides this publication as is without warranty of any kind, either express or implied, including, but

More information

PC-controlled Gel Documentation Systems Felix

PC-controlled Gel Documentation Systems Felix PC-controlled Gel Documentation Systems Felix UV-Fluorescence VIS-Fluorescence It s all about Bio-Imaging. www.biostep.de Felix 1010 - Getting started easily powerful digital reflex camera with manual

More information

TECHNICAL INFORMATION Forensic Optical Comparator Catalog Nos. FX8B, FX8B220

TECHNICAL INFORMATION Forensic Optical Comparator Catalog Nos. FX8B, FX8B220 SIRCHIE Products Vehicles Training Copyright 2011 by SIRCHIE All Rights Reserved. TECHNICAL INFORMATION Forensic Optical Comparator Catalog Nos. FX8B, FX8B220 INTRODUCTION The FX8B is an opaque projector

More information

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual EQUIPMENT Operation Manual Loctite LED Light Sources Part Number 1427232 Model 7700-HD, LED Light Source II, 395 nm Peak Part Number 98665 Model 7703-HD, >400 nm Pure Visible Light Source 1 TABLE OF CONTENTS

More information

User s Guide. POWERVAR Single Phase Power Conditioners

User s Guide. POWERVAR Single Phase Power Conditioners POWERVAR Single Phase Power Conditioners User s Guide Industrial Conditioners GPI Series B Conditioners GPI Series 1 Conditioners 2-15 kva Single Phase Conditioners GPI Series 1 Conditioners RoHS Compliant

More information

OPERATOR MANUAL for the Kodak X-Omatic IDENTIFICATION CAMERA MODELS 4, 4L, and 4SL

OPERATOR MANUAL for the Kodak X-Omatic IDENTIFICATION CAMERA MODELS 4, 4L, and 4SL Publication No. 990601 January 1996 Supersedes 990601 August 1993 OPERATOR MANUAL for the Kodak X-Omatic IDENTIFICATION CAMERA MODELS 4, 4L, and 4SL Eastman Kodak Company PLEASE NOTE The information contained

More information

What s in the Box? REAR VIEW SAFETY

What s in the Box? REAR VIEW SAFETY TM 1 What s in the Box? 1 Full HD Color Infra-red Weather Proof Camera 1 Full HD 7" TFT LCD Color Monitor w/monitor Mount 1 Power Harness 1 66 Camera Cable 1 Power Connection Wire 1 Screw Kit for installation

More information

Richter Optica. Instructions for Model: MDS2 Middle School Microscope

Richter Optica. Instructions for Model: MDS2 Middle School Microscope Richter Optica info@richter-optica.com Instructions for Model: MDS2 Middle School Microscope Eyepiece 360 Rotatable Head Revolving Nosepiece Carrying Handle Objectives Rack Stop Stage Stage Clips Disc

More information

Table of Contents. Chapter 1. Safety Precautions Notice Chapter 2. Components and accessories Chapter 3. Camera components...

Table of Contents. Chapter 1. Safety Precautions Notice Chapter 2. Components and accessories Chapter 3. Camera components... P. 770.270.1394 F. 770.270.2389 865 Marathon Parkway Lawrenceville GA 30046 P. 770.270.1394 F. 770.270.2389 865 Marathon Parkway Lawrenceville GA 30046 Table of Contents Chapter 1. Safety Precautions Notice...

More information

Series 803 LED Product Price Display

Series 803 LED Product Price Display Series 803 LED Product Price Display May 2007 Rev. 1.1 1 Installation and Operation Manual Table of contents 1. Safety.......3 2. Series 803 sign features.......4 2.1 Sign descriptions........4 2.2 Control

More information

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE

User s Manual. PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE PC-HELPER PCI Bus Expansion Adapter for PCI Bus PC-Slot EAD(PCI)BE PCI Bus Expansion Adapter for Low Profile PCI PC-Slot EAD(LPCI)BE User s Manual CONTEC CO.,LTD. Check Your Package Thank you for purchasing

More information

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual

Omnitron Systems Technology, Inc. 1. iconverter. 19-Module Managed Power Chassis User s Manual Omnitron Systems Technology, Inc. 1 iconverter 19-Module Managed Power Chassis User s Manual 27 Mauchly, #201, Irvine, CA 92618 Phone: (949) 250-6510; Fax: (949) 250-6514 2 Omnitron Systems Technology,

More information

PLEASE READ BEFORE OPERATING THIS EQUIPMENT.

PLEASE READ BEFORE OPERATING THIS EQUIPMENT. PLEASE READ BEFORE OPERATING THIS EQUIPMENT. HALO BOLT ACDC WIRELESS Thank you for choosing HALO! Powerful, compact and easy to use, the HALO BOLT ACDC WIRELESS can safely jump start your car or charge

More information

9040/9040UK. Users Manual. Phase Rotation Indicator

9040/9040UK. Users Manual. Phase Rotation Indicator 9040/9040UK Phase Rotation Indicator Users Manual PN 2438546 April 2005 2005 Fluke Corporation. All rights reserved. Printed in China All product names are trademarks of their respective companies. LIMITED

More information

IMPORTANT PLEASE READ FIRST

IMPORTANT PLEASE READ FIRST TORQ NV USER MANUAL TABLE OF CONTENTS Specifications...2 Components...4 Battery Installation...5 Basic Functions...6 Lockout/Ready Mode...6 Momentary Mode...6 Primary Control...7 Secondary Control...7

More information

burst laser

burst laser burst laser USERS MANUAL www.venuelightingeffects.com Introduction Congratulations on your purchase of Venue s Burst Laser. Designed to operate as a simple stand-alone unit or external addition to your

More information

Operation & Service Manual

Operation & Service Manual Operation & Service Manual EM19191 www.intertest.com 303 Route 94 Columbia, NJ 07832 908.496.8008 Table of Contents Introduction 3 Customer Support 4 Warranty Information 5 System Overview 6 Assembly Connection

More information

DOT MATRIX PRINTER SP6000 SERIES

DOT MATRIX PRINTER SP6000 SERIES DOT MATRIX PRINTER SP6000 SERIES Hardware Manual < Approval: CEL > Trademark acknowledgments SP6000 : Star Micronics Co., Ltd. Notice All rights reserved. Reproduction of any part of this manual in any

More information

Variable-Speed Vortex Mixer

Variable-Speed Vortex Mixer Variable-Speed Vortex Mixer User Guide Version 1.1 IEC connector Retort rod fitting Rubber cup Speed control dial Power on/off button Mode button Figure 1: Vortex Mixer Figure 2: Front panel 2 Variable-Speed

More information

User Manual. Trinocular Stereo Microscope

User Manual. Trinocular Stereo Microscope User Manual Trinocular Stereo Microscope Model V434 XV434 Series MicroscopeNet.com Table of Contents i. Caution.. 1 ii. Care and Maintenance... 2 1. Component Illustration... 3 2. Installation 4 3. Operation....6

More information

Start Here. All-in-One Printer. Print Copy Scan

Start Here. All-in-One Printer. Print Copy Scan Start Here All-in-One Printer Print Copy Scan Note: A USB 2.0 (High Speed) cable is required to connect your Kodak All-in-One printer to your Windows or Macintosh OS computer. Black Ink Cartridge Color

More information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A 3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and

More information

HP Deskjet F2100 All-in-One series. Basics Guide

HP Deskjet F2100 All-in-One series. Basics Guide HP Deskjet F2100 All-in-One series Basics Guide Hewlett-Packard Company notices The information contained in this document is subject to change without notice. All rights reserved. Reproduction, adaptation,

More information

DoorEye Camera MDOOREC101012E

DoorEye Camera MDOOREC101012E DoorEye Camera MDOOREC101012E 1 Package Contents What is included: 2.8 TFT LCD monitor, Outdoor camera, Bracket, Connector, Installation stud, Wrench, Lithium battery, Screws x 4, Theft deterent stickers

More information

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL

ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL ESV1018 Quantum Illuminator Cabinet INSTRUCTION MANUAL Universal Power Supply EVS1018 Illuminated Cabinet Battery Pack: Optional Charts Charts HOTV Charts Letter Charts and Tumbling E More charts available

More information

Gel Documentation System

Gel Documentation System Gel Documentation System Gel Documentation System Major Science offers a wide range of Gel Documentation System specifically designed to fit researchers specifications and budgets. Gel Documentation System

More information

GOODJOB. ICAN-FluorUV Easy Guide. Contents. Before Installation (Make Sure You Have) 1. Preparing the Camera Installing Camera and Filter...

GOODJOB. ICAN-FluorUV Easy Guide. Contents. Before Installation (Make Sure You Have) 1. Preparing the Camera Installing Camera and Filter... GOODJOB ICAN-FluorUV Easy Guide Contents Before Installation (Make Sure You Have) 1 Preparing the Camera... 2 Installing Camera and Filter... 2 Reading This First... 2 Getting Started 2 Before installation

More information

Instrument Prep & Pack Tables... Ergonomic/Hydraulic

Instrument Prep & Pack Tables... Ergonomic/Hydraulic Instrument Prep & Pack Tables... Ergonomic/Hydraulic KTW Medical offers the finest ergonomic solution with push button height adjustability. Designed to maximize productivity and reduce overexertion we

More information

SP-C1 Mobile Docking Station Installation Guide

SP-C1 Mobile Docking Station Installation Guide SP-C1 Mobile Docking Station Installation Guide Box Contents After you unpack your SP-C1 Mobile Docking Station, make sure everything here is included: 1 x Docking Cradle 1 x Audio Cable 1 x Adhesive Mount

More information

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display

Installation Manual. Model: HILU Ultra HD Interactive Flat Panel Display Installation Manual Model: HILU750 '' Ultra HD Interactive Flat Panel Display QUICK SETUP GUIDE For further information, see the User Manual. Please contact HITACHI directly if you have questions on the

More information

Polarization Microscope. Omano OM349P Series. User Guide

Polarization Microscope. Omano OM349P Series. User Guide Polarization Microscope Omano OM349P Series User Guide Table of Contents Getting Started... 3 Components... 3 Technical Specifications... 5 Setup Instructions... 6 Basic Operation... 7 Changing the Light

More information

Flex Pro Series Assembly Guide

Flex Pro Series Assembly Guide ELECTRIC HEIGHT-ADJUSTED SIT TO STAND DESK Table of Contents CAUTION, USE & LIABILITY... 2 PARTS & HARDWARE LIST... 3 PARTS / COMPONENT DIAGRAMS... 3 ASSEMBLY INSTRUCTIONS... 5 BLUETOOTH... 10 TROUBLESHOOTING...

More information

Thermal Imaging Camera 220 x Instruction Manual

Thermal Imaging Camera 220 x Instruction Manual Thermal Imaging Camera 220 x 160 800201 Instruction Manual 1 TABLE OF CONTENTS INTRODUCTION... 3 FEATURES... 4 MATERIALS SUPPLIED... 4 FRONT PANEL DESCRIPTION... 5 LCD DISPLAY... 6 SET UP... 7 MEASUREMENT

More information

AE21 SERIES DISPLAY CONTROL TERMINAL

AE21 SERIES DISPLAY CONTROL TERMINAL FN:AE21MAN1.DOC AE21 SERIES DISPLAY CONTROL TERMINAL DESCRIPTION The AE21 Series Display Control Terminal is used for implementing various display functions. It consists of a control terminal, the AE21,

More information

Led Illuminator and Light Stimulator. Model # LSD-1. Ver

Led Illuminator and Light Stimulator. Model # LSD-1. Ver Led Illuminator and Light Stimulator Model # LSD-1 Ver. 2.0.0 5.16 ALA Scientific Instruments Inc. 60 Marine Street, Farmingdale, NY 11735 Voice: +1 631.393.6401 fax: +1 631.393.6407 www.alascience.com

More information

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide

OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications

More information

Richter Optica. Instructions for Model: HSX1 High School Microscope

Richter Optica. Instructions for Model: HSX1 High School Microscope Richter Optica info@richter-optica.com Instructions for Model: HSX1 High School Microscope Eyepiece 360 Rotatable Head Objectives Carrying Handle Revolving Nosepiece Rack Stop Slide Holder Focus Tension

More information

OMM200 and OMM200T. Metallurgical Microscope

OMM200 and OMM200T. Metallurgical Microscope OMM200 and OMM200T Metallurgical Microscope Instruction Manual (Please read the manual carefully before using the microscope) Contents Safety ----------------------------------------------------------------------------

More information

20W Tungsten-Halogen Light Source. Operation Manual

20W Tungsten-Halogen Light Source. Operation Manual 20W Tungsten-Halogen Light Source - ASB-W-020 - Operation Manual Important Safety Notices 1. Never look directly into the light beam, including through the cooling fan while light is on, as this can cause

More information

TENDER NOTICE. Office: Principal, Gurudas College, Narkeldanga, Kolkata

TENDER NOTICE. Office: Principal, Gurudas College, Narkeldanga, Kolkata TENDER NOTICE Office: Principal, Gurudas College, Narkeldanga, Kolkata 700054 Tender Specification No: BOOST/GC/2015/1-5 dated 30-04-2015 Address Principal: Gurudas College 1/1, Suren Sarkar Road; Narkeldanga;

More information

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only.

This 4200-RM Rack Mount Kit is for installation in 4200-CAB series cabinets only. Keithley Instruments, Inc. 28775 Aurora Road Cleveland, Ohio 44139 (440) 248-0400 Fax: (440) 248-6168 www.keithley.com Model 4200-RM Rack Mount Kit Packing List Introduction NOTE This 4200-RM Rack Mount

More information

Table of Contents List of Equipment General Information Safety Precautions Device Installation...

Table of Contents List of Equipment General Information Safety Precautions Device Installation... Table of Contents Table of Contents.... List of Equipment... 3. General Information... 4 3. Safety Precautions... 6 3. Device Installation... 7 6. Device Operation... 0 7. Statement of Limited Warranty...

More information

Pulse LED Instruction Guide

Pulse LED Instruction Guide PARTS LIST Light Fixture Aquarium Frame Mounts Instruction Guide WARNING: To guard against injury, basic precautions should be observed, including the following: A) READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

More information

OXY 4 Air Sterilizer. Ultra Violet Advanced Air Treatment System

OXY 4 Air Sterilizer. Ultra Violet Advanced Air Treatment System TM OXY 4 Air Sterilizer Ultra Violet Advanced Air Treatment System EXTENDED SURFACE AREA WITH CATALYTIC REACTIONS FOR ADVANCED PLASMA OXIDIZERS USB PROGRAMMING PORT OXY 4 LED SMART LIGHT MONITOR PROGRAMMABLE

More information

1U Short-Depth Rackmount Console with 19 Display For KVM Switch or Server

1U Short-Depth Rackmount Console with 19 Display For KVM Switch or Server WARRANTY REGISTRATION: register online today for a chance to win a FREE Tripp Lite product www.tripplite.com/warranty Owner s Manual 1U Short-Depth Rackmount Console with 19 Display For KVM Switch or Server

More information

3D OBJECTS RGB LASER. Order ref: UK User Manual

3D OBJECTS RGB LASER. Order ref: UK User Manual TECHNICAL SPECIFICATION Voltage : 230Vac, 50/60Hz Blue : 300mW 455nm Fuse : 2A Slow blow DMX Channels : 20 Dimensions : 220 x 176 x 99mm Laser Class : 3B Red Laser: 100mW 638nm Power Consumption : 45W

More information

User's Guide Video Borescope Model BR200

User's Guide Video Borescope Model BR200 User's Guide Video Borescope Model BR200 Introduction Congratulations on your purchase of this Extech BR200 Video Borescope. This instrument was designed for use as a remote inspection device. It can be

More information

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera

INSTALLATION MANUAL. ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera INSTALLATION MANUAL ST-BTWD650IR2812 B or W Weatherproof Day/Night Infrared Color Camera PACKAGE CONTENTS This package contains: One ST-BTWD650IR2812 camera with Black or White housing One extension tube

More information

Bluetooth Ceiling Fan Control with App Owner's Manual

Bluetooth Ceiling Fan Control with App Owner's Manual READ AND SAVE THESE INSTRUCTIONS 0 Model Number RCBT00 Bluetooth Ceiling Fan Control with App Owner's Manual -Speed Hand Held Transmitter Single Light Supplied with Receiver Includes Light Dimming Selection

More information

10 Digital Photo Frame Instructional Manual

10 Digital Photo Frame Instructional Manual 10 Digital Photo Frame Instructional Manual aluratek.com mnl M10403 model ADMPF410T Copyright 2016 Aluratek, Inc. All Rights Reserved. Table of Contents Frame Features... Frame Control Close-up... Remote

More information

EQUIPMENT Operation Manual

EQUIPMENT Operation Manual EQUIPMENT Operation Manual 7700 Label # 988830 Loctite Handheld LED Light Sources Part Number 1427231 Model 7700 Light Source II Part Number 98595 Model 7703 Light Source TABLE OF CONTENTS 1. PLEASE OBSERVE

More information

ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software Installation Qualification Protocol (IQ)

ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software Installation Qualification Protocol (IQ) ChemiDoc and ChemiDoc MP Imaging Systems with Image Lab Touch Software Protocol (IQ) Catalog #17001401 and 17001402 Table of Contents Page Section 1: General Information... 3 1.1 Scope... 3 1.2 Protocol

More information

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T.

G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T. G500 SERIES MICROSCOPE OPERATION MANUAL For use with MFR# G502, G502T, G504, G504T, G505, G505T. United Products & Instruments, Inc. 182 Ridge Road, Suite E Dayton, NJ 08810 USA T. 732 274 1155; F. 732

More information

LET OUR IMAGE ENHANCE YOUR IMAGE. Operating Instructions MedRx JVC Portable Video OtoScope System

LET OUR IMAGE ENHANCE YOUR IMAGE. Operating Instructions MedRx JVC Portable Video OtoScope System LET OUR IMAGE ENHANCE YOUR IMAGE Operating Instructions MedRx JVC Portable Video OtoScope System JVC Portable Video Otoscope Manual Rev 1 Effective August 2003 Table of Contents Introduction to the MedRx

More information

Lexmark X203n and X204n Series. Maintenance Guide

Lexmark X203n and X204n Series. Maintenance Guide Lexmark X203n and X204n Series Maintenance Guide February 2011 www.lexmark.com Contents...3 Cleaning the exterior of the printer...3 Cleaning the scanner glass...4 Cleaning the ADF separator rollers...5

More information

User Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series

User Manual RKD-KVM-20 / RKDS-KVM-20. WRKD-KVM-19 / WRKDS-KVM-19 Series. Series User Manual RKD-KVM-20 / RKDS-KVM-20 Series - 1U 20" LCD keyboard drawer - Resolution up to 1600 x 1200 - Full range KVM options WRKD-KVM-19 / WRKDS-KVM-19 Series - 1U widescreen 19" LCD keyboard drawer

More information

X940e, X945e. Maintenance Guide

X940e, X945e. Maintenance Guide X940e, X945e Maintenance Guide July 2010 www.lexmark.com Contents...3 Storing supplies...3 Checking the status of supplies...3 Checking the status of supplies from the control panel... 3 Printing a menu

More information

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC

MultiTherm Shaker. Operations Manual Item: H5000-H and H5000-HC MultiTherm Shaker Operations Manual Item: H5000-H and H5000-HC Foreword Thank you for purchasing a MultiTherm Shaker. This operations manual contains instructions for the care of this Instrument. In order

More information

USERS GUIDE MCX-STH. 3G SDI to HDMI Converter. Manual Number:

USERS GUIDE MCX-STH. 3G SDI to HDMI Converter. Manual Number: USERS GUIDE MCX-STH 3G SDI to HDMI Converter i Manual Number: 151226 SAFETY INSTRUCTIONS Please review the following safety precautions. If this is the first time using this model, then read this manual

More information

MONARCH 9416 XL QUICK REFERENCE

MONARCH 9416 XL QUICK REFERENCE MONARCH 9416 XL QUICK REFERENCE This Quick Reference contains ribbon loading, supply loading, and general care, maintenance, and troubleshooting procedures for the 9416 XL Thermal Direct and 9416 XL Thermal

More information

i-series Videoconference Fixture

i-series Videoconference Fixture TM i-series Videoconference Fixture Operating Instructions 580 Mayer Street, Building #7, Bridgeville, PA 15017 phone 412.206.0106 fax 412.206.0146 www.brightlines.com 2013 Brightline, L.P. Safety To prevent

More information

CUBE Micro Station User Guide

CUBE Micro Station User Guide CUBE Micro Station User Guide Models TVS10AC CUBE Micro Station - User Guide 1 of 23 How To Use This Guide This User Guide is a resource to provide you guidelines and best practices as you begin using

More information

MX-T6-PRO/S Tube Rollers

MX-T6-PRO/S Tube Rollers MX-T6-PRO/S Tube Rollers User Manual MX-T6-Pro MX-T6-S LCD Digital Tube Roller Classic Tube Roller Please read the User Manual carefully before use, and follow all operating and safety instructions! Technical

More information

ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL

ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL ESV1200 Quantum Illuminator Cabinet INSTRUCTION MANUAL Universal Power Supply ESV1200 Illuminated Cabinet Charts Charts HOTV Charts Letter Charts 2 ESV1200 Quantum Viewer Table Of Contents Introduction.......

More information

FT-01. describes are subject to change without prior notice.

FT-01. describes are subject to change without prior notice. Finger Touch Unit Model name FT-01 User s Manual Thank you for purchasing a Finger Touch Unit specially designed for Hitachi LCD projectors. Be sure to read this manual and the User s Manual supplied with

More information

ivu TG Gen2 Image Sensor with Integrated Display

ivu TG Gen2 Image Sensor with Integrated Display Datasheet The ivu image sensor is used to monitor parts for type, size, orientation, shape, and location. The ivu TG Gen2 Image Sensor package consists of lighting, sensor, lens, and display. Appropriate

More information

User Manual. Binocular Stereo Microscope. MicroscopeNet.com

User Manual. Binocular Stereo Microscope. MicroscopeNet.com User Manual Binocular Stereo Microscope Model K2213 Series MicroscopeNet.com Table of Contents i. Caution... 1 ii. Care and Maintenance... 1 1. Components Illustration... 2 2. Installation... 3 3. Operation...

More information

RANGER. Digital Trail Camera Instructions for use: Model BN057

RANGER. Digital Trail Camera Instructions for use: Model BN057 RANGER Digital Trail Camera Instructions for use: Model BN057 In d e x 1. Introduction... 3 2. Specifications... 3 3. Parts identification... 5 4. Package contents... 6 5. Battery and SD card installation...

More information