Daniel Senior Orifice Fitting Differential Pressure Flow Meters. Technical Guide May 2013

Size: px
Start display at page:

Download "Daniel Senior Orifice Fitting Differential Pressure Flow Meters. Technical Guide May 2013"

Transcription

1 Daniel Senior Orifice Fitting Differential Pressure Flow Meters Technical Guide May 2013

2

3 Differential Pressure Flow Meters Technical Guide Proving its worth every day Overview The Daniel Senior Orifice Fitting is a dual-chamber device that reigns as the most widely used means of measurement for natural gas. With an installed base of well over one million orifice fittings worldwide, more natural gas is measured with The Daniel Senior Orifice Fitting than any other type of device. The Senior Orifice Fitting (Figure 1) saves users time and money by providing a fast, safe and extremely simple method of changing orifice plates under pressure without flow interruption, preventing unscheduled shutdowns. In addition, its dual-chamber design eliminates the need for costly piping bypasses or additional valves and fittings required with conventional orifice flange installations. The Senior Orifice Fitting meets all requirements and recommendations for accurate flow measurement of gas and liquid, including AGA-3 / API 14.3 requirements, without compromise. From duplex stainless steel fittings to carbon steel and severe service trims (Monel, Hastellloy-C and Alloy-20), Daniel delivers fittings to meet the stringent requirements of corrosive environments or specific temperature and pressure needs. The Senior Orifice Fitting requires no beta ratio range restrictions and no added uncertainty to published values. It is available in 2" through 48" flange line sizes, up to ANSI 2500, and 10,000 psi (68958 kpa) in 3" to 6" only. Typical Applications Gas transmission / pipeline Gas distribution Offshore gas production and onshore, including shale Gas plants Floating Production, Storage and Offloading (FPSO) CO 2 injection Bi-directional high pressure storage Features and Benefits Highly reliable, time proven technology Field-repairable, reducing downtime and costs associated with shipping to a repair site Available in compliance with ISO-5167, PED, NORSOK and other code standards / requirements (1) Corrosion resistant and other special casting materials, including Wrought Carbon Steel (WCC, WCB), Low Temperature Carbon Steel (LCC), 316 Stainless Steel and Duplex, makes this fitting suitable for sour gas service and other special applications Slide valve / isolation mechanism featuring a metal-tometal seat (hard seat (2) ) with injected lubricant / sealant is standard on all Daniel Senior Orifice Fittings, providing an optimal seal in the production environment where particulate matter is common Optional soft seat slide valve (3) (O-ring seal without lubricant) is available in 2" to 12" sizes, up to 600 ANSI, for use with gas products such as ethylene Figure 1: Daniel Senior Orifice Fitting (1) Please consult Daniel factory for severe service and other code requirements, including low -temp, high H 2 S, high CO 2, and special applications. (2) Hard-seat using injected grease / sealant is recommended for production applications where sand, grit and other particulate matter is present. (3) Soft-seat, greaseless seal is not recommended / intended for production applications where sand, grit and other particulate matter is commonly present (e.g., shale gas production). 1

4 Senior Orifice Fitting May 2013 Operational Sequence of Removing an Orifice Plate Under Pressure (1) A. Under flow conditions B. Equalize pressure 1. Open equalizer valve C. Raise orifice plate 2. Open slide valve carrier (isolation mechanism) 3. Raise plate to upper chamber D. Bleed upper chamber and lubricate valve seat 4. Close slide valve carrier (isolation mechanism) 5. Close equalizer valve and inject sealant 6. Open bleeder valve (blow-down valve) (1) CAUTION: This operational sequence is representational only and is not intended for use as a field guide to operations. NOTICE: See operation manual and always read and follow the detailed operating instructions provided with each fitting before attempting to operate. 2

5 Differential Pressure Flow Meters Technical Guide Top Chamber Valve Seat Sealing Surface Valve Seat Gasket Slide Valve Seat Stop Pin Slide Valve Strip Slide Valve Springs Slide Valve Carrier Operating shaft and Pinion E. Remove orifice plate 7. Remove clamping bar, sealing bar, and gasket 8. Remove orifice plate from top chamber The slide valve seat and the slide valve strip are field-replaceable or repairable (re-lapping) without removing the fitting from the line, reducing downtime. Senior Orifice Fitting Front View 3

6 Senior Orifice Fitting May 2013 Standard Specifications (1) Differential Pressure Taps Internal Tap Hole Sizes In accordance with API 14.3 (AGA Report #3) In accordance with ISO-5167 (option) 1/2" NPT Process Connection (Standard) In accordance with API 14.3 (standard for all) Flanged differential taps (option) Telemetering Taps Standard on all 2 to 12 inch 600 ANSI Available on all other sizes and ANSI classes Line Bore Tolerances 2" and 3" sizes, ±.003" 4", 6", 8", 10" sizes, ±.004" 12" and 16", ±.005" Operating Shafts Stainless Steel, double-ended (standard) Eliminates the need to reverse shafts in the field Application Temperature Maximum Temperatures (2) 150 to 900 ANSI, -20 F to +450 F (2) (-29 C to 232 C) Indicator Plates Standard on all Senior Orifice Fittings, the indicator plate clearly shows the direction of the open and closed position of the slide valve. Operating Wrench An operating wrench is provided with each fitting for safe operation of the shaft and pinions, equalizer valve, grease gun, bleeder valve and clamping bar screws. Hydrostatic Testing All Daniel Senior Orifice Fittings are hydrostatically tested to 1.5 times operating pressure. Trim NACE Trim (MR ) 2" to 8" 150 to 600 ANSI RFFN Fittings (Standard) A-trim 10" + and all ANSI classes 900+ (Standard) Other optional trims available for severe service and other code requirements (High H 2 S, High CO 2, NORSOK, Daniel AASG and special applications) 1500 and 2500 ANSI, -20 F to +275 F (2) (-29 C to 135 C) Senior Orifice Fitting - Flanged Configuration Senior Orifice Fitting - Flangnek TM Configuration (1) Please consult Daniel if your requirements are outside the specifications. Other product and material offerings may be available depending on the application. (2) Orifice Plate Seal used may limit the service temperatures and special trims will be required for high temperature applications. Maximum temperature is contingent on limited pressure. Please consult factory. 4

7 Differential Pressure Flow Meters Technical Guide Special Features High Pressure Fittings Double row clamping bar screws (constraining force directly over gasket) Thin section on internal edge for flexible lip seal, yielding easily to pressure Heavy weight section on external edge to prevent compression drift between joints Robust Carbon Steel clamping and sealing bars Force exerted on surface tending to change its shape will not affect gasket seal Constant pressure seals gasket at all times Alloy steel studs Daniel Sealing Bar Gasket Corrosion resistant slide valve seat Heavy wall sections Oversized stuffing box units Figure 2: Partial Side Sectional Elevation Daniel ANSI 1500 and 2500 (1) Fittings Figure 2 shows the extra-heavy construction of the wall sections and essential parts on the ANSI 1500 Senior Orifice Fitting. All seal ring units for use in 900 to 2500 ANSI fittings are required to be Snap Seal or PTFE Seal Rings. 36 inch ANSI 600 Senior Orifice Fitting (1) NOTE: Body / Top Gasket peroxide-cured Nitrile O-ring for ANSI 1500 Orifice Fittings. Male and female gasket joint with Parker TM seal gaskets for ANSI 2500 Orifice Fitting. 5

8 Senior Orifice Fitting May 2013 Alignment of Meter Tube Flange to Orifice Fitting Flange On all sizes, 300 ANSI or under, three dowel pin flangealignment holes are drilled in the flanges. On Daniel 400 ANSI fittings or higher, flanges are manufactured with close-tolerance, square-shouldered, large male flange-facing on fitting, and large female flange-facing on meter tube to assure proper internal alignment. Flange gaskets are precision-cut so they will not, under compression, extend into the internal bore of fitting. Refer to Figure 3. Meter Tube Flange Daniel 125 to 300 ANSI Fitting Flange Daniel 400 and Higher ANSI Slide Valve (1) Figure 3: Method of Aligning Meter Tube Flange to Orifice Fitting Flange Continuous Grease Groove (Encircle Valve Opening) Top Chamber Equalizer Passageways Grease Gun (Part No. 23) Equalizer Valve (part No. 1) Slide Valve Seat (Part No. 18) Slide Valve Carrier (Part No. 17) Slide Valve Strip (Part No. 3) Clearance pad prevents slide valve from being closed until plate carrier is fully centered in the line. Lower Compartment In Daniel Senior Orifice Fittings, the slide valve seat (Part No. 18) is part of the upper chamber. The slide valve strip (Part No.3) moves underneath this seat, thereby utilizing line pressure to affect a positive seal. The slide valve strip is maintained in the floating position by minimum spring pressure. Before the slide valve (Figure 4) is opened, sealant (lubricant) is injected using the grease gun (Part No. 23). Pressure is Figure 4: Slide Valve / Isolation Mechanism (2) then equalized throughout the entire fitting by operation of the equalizer valve (Part No. 1). Equalized pressure on both sides of the slide valve strip allows slide valve to move freely without wear. The metal-to-metal hard seat seal (with injected sealant / lubricant) provides an optimal and reliable seal in the production environment where sand and particulate matter are common. (1) CAUTION: This view is representational only and is not intended for use as a field guide to operations. NOTICE: See operation manual and always read and follow the detailed operating instructions provided with each fitting before attempting to operate. (2) Slide valve / Isolation mechanism does not comply with or adhere to API 598 valve criteria. Hard seat (using sealant / lubricant) is standard on all Daniel Senior Orifice Fittings.Soft seat (O-ring seal using no grease) is available in size 2" to 12" up to 600 ANSI. Not intended for production applications. 6

9 Differential Pressure Flow Meters Technical Guide Plate Alignment The plate carriers in all 2" to 8" Senior Orifice Fittings are centered using a fixed three-point positioning system. This assures orifice plate concentricity in accordance with current API 14.3 (AGA Report #3) tolerances while the fitting is positioned in the vertical and horizontal planes. The Senior Orifice Fitting is composed of two independent compartments separated by a hardened stainless steel slide valve. wrench. This method provides the safest means of operation with the least amount of effort and assures positive control of the plate carrier at all times (1). All parts, including the essential slide valve assembly, may be replaced or repaired without removing the fitting from the line. The side sectional view, Figure 5, demonstrates the slide valve in theclosed position and orifice plate concentric in line of flow. The slide valve cannot be closed unless the orifice plate is concentric to the bore of the fitting or in the upper chamber during plate removal. Figure 6 demonstrates the Daniel top chamber in the opened position with the plate carrier in place for change or inspection of the orifice plate. Only a few turns of the operating wrench are required to loosen screws to remove or replace clamping and sealing bars. Set screws always remain in the clamping bar. This feature adds greatly to speed and ease of operation. The plate carrier is raised and lowered by a double rack and pinion mechanism with power applied through an operating Figure 5: Side Sectional View of Daniel Senior Orifice Fitting Figure 6: Daniel Senior Orifice Fitting - Top Chamber Open The Senior Orifice Fitting Advantage Orifice Plate Sealing Units Designed by Daniel, the plate sealing units provide a secure seal between orifice plate and body seats and can be used for a variety of services. Plate Carrier The plate carrier protects orifice plate at all times while inserting or removing from the fitting and can be easily inserted while fitting is rolled in the horizontal position. Indicator Plate The indicator plate clearly shows the position of the slide valve within the fitting. Compact Design The compact design of the Senior Orifice Fitting requires minimum operating space. Fittings Daniel Senior Orifice Fittings up to and including 12" line size can operate in a vertical down flow condition or positioned in horizontal flow for side opening. All fittings are designed and manufactured to meet API / AGA recommendations, and in strict accordance with A.S.T.M. specifications. For other code requirements and special applications, including NORSOK, ISO, PED, CO 2, H 2 S, low temperature, please consult factory. PTFE Shaft Packing and Centering Rings The PTFE shaft packing and centering rings are standard equipment on all Daniel Senior Orifice Fittings in all sizes and ratings. (1) CAUTION: This is not intended for use as a field guide to operations. NOTICE: See operation manual and always read and follow the detailed operating instructions provided with each fitting before attempting to operate. 7

10 Senior Orifice Fitting May 2013 Orifice Plate Sealing Units Orifice plates manufactured by Daniel are quality-controlled from the selection of raw materials to packaging of finished products. The orifice plate sealing unit provides a seal between orifice plate and body seats and it is available for a variety of services. Dual Seal (DSC) The Dual Seal (DSC) is the most simple and practical orifice plate sealing device for normal flowing streams. It is precision molded from shore nitrile synthetic rubber (1) and provides four rubber-to-metal sealing surfaces 360 around the plate. The units securely seal against both outer faces of the plate and against both seats of the orifice fitting to prevent leakage. In 16" sizes and up, DS seal rings are not available. The Dual Vulcanized Seal (DVS) is bonded from shore rubber directly to the outer edge of the orifice plate at the factory. If damaged, the DVS seal and plate may be returned to the factory for revulcanizing. The DSC and DVS seals are used in Daniel fittings sizes up to ANSI 600, in temperatures from -20 F to +275 F. Snap Seal Ring (SSR) The Snap Seal Ring (SSR) unit is a removable orifice plate holder designed for use where elastomer seal swelling is a problem. Certain media, such as ethylene or carbon dioxide may cause seal swelling when other types of seal units are removed from high-pressure service. The Snap Seal Ring unit consists of two symmetrical metal rings, each one having an O-ring on both sides for a secure seal on the plate side and the fitting side of the ring. The orifice plate is centered and secured between these rings. The assembled unit provides a full 360 rubber-to-metal seal around both sides even in the absence of pressure differential. No special tools are required for assembly or disassembly. When ordering, please specify nominal line size, schedule, plate thickness, and flowing media or material choice. Dual Seal (DSC) in 2" to 8", (DS) in 10" to 12" Materials 2" to 10": shore nitrile synthetic rubber (1) 12" and up: shore rubber Operating Temperature -20 F to +275 F Available Sizes 2" to 12" ANSI Up to 600 Snap Seal Ring (SSRC) in 2" to 8", (SSR) in 10" to 24" Materials 316 stainless steel Zinc-plated carbon steel Duplex and Inconel available Operating Temperature -20 F to +275 F (standard O-rings) -67 F to +437 F (FKM Fluoroelastomer O-rings) (2) Available Sizes 2" to 24" ANSI 900, 1500 and 2500 (1) Also available in FKM Fluoroelastomor. (2) FKM is the designation for a class of fluoroelastomers as defined in ASTM D1418 and ISO

11 Differential Pressure Flow Meters Technical Guide PTFE Seal (TSC) The PTFE Seal (TSC) is a superior orifice plate seal unit for difficult, corrosive flows and for higher temperatures than the Dual Seal (DSC) unit can handle. The TSC has proven effective in flows such as dilute sulphuric acid, fuming nitric acid, hydrazine, liquid oxygen and other unusual flows, from -65 F to +500 F (1). The two-piece unit consists of an inlet ring which fits around the plate outer diameter, and a downstream ring fitted with metal clips for assembling the orifice plate sealing unit. A unique and an annular groove (2) on the ring provides compression to effectively seal off the plate. The TSC unit can be assembled or taken apart by hand and is interchangeable in 2" to 10" sizes with Daniel Dual (DSC) and Metal (MSC) Seal units. The TSC is recommended with Daniel 900, 1500 and 2500 ANSI fittings or lower pressure where rubber seals may not be satisfactory. Metal Seal (MSC) (3) The Metal Seal (MSC) is a stainless or zinc-plated carbon steel clip-ring assembly recommended for high pressures and for temperatures up to 1200 F (4). The assembly consists of an upstream and a downstream ring. The upstream ring has a recessed groove into which a thin leaf-spring is inserted. A seal is created by clamping the plate between the rings, thereby providing the necessary compression to seat the plate against the downstream ring. Metal Seal units of zinc-plated carbon steel are recommended for services to +600 F (4), standard 316 stainless steel units to F (4), and 316 stainless steel units with an inconel spring to F (4). The Metal Seal unit can be assembled or taken apart by hand and is interchangeable in 2" to 12" sizes with Dual Seal (DSC) and PTFE Seal (TSC) units. PTFE Seal (TSC) in 2" to 8", (TS) in 10" to 24" Materials PTFE Seal (900, 1500 and 2500) Operating Temperature -65 F to +500 F Available Sizes 2" to 10" ANSI 900, 1500 and 2500 Metal Seal (MSC) in 2" to 8", (MS) in 10" to 24" Materials 316 stainless steel seal (standard) Zinc-plated carbon steel seal Operating Temperature (1) 450 F (316 stainless steel) standard 450 F (316 stainless steel) with an inconel spring 450 F (zinc-plated carbon steel) Available Sizes 2" to 24" ANSI 900, 1500 and 2500 (1) For higher temperatures, please consult factory. (2) This groove should be spread by inserting a tool such as a screw driver and rotating 360 to re-engage the spring lip after each use. NOTICE: See operation manual and always read and follow the detailed operating instructions provided with each fitting before attempting to operate. (3) Not intended for custody transfer accuracy applications. (4) Application temperatures above 450 F are intended for single chamber devices and require factory consultation. 9

12 Senior Orifice Fitting May 2013 Orifice Plate Carrier Daniel s new plate carrier reduces measurement uncertainty using a three-point positioning system. This assures concentricity within the fitting in accordance with the API 14.3 (A.G.A. Report #3) and ISO-5167 standards. Metalto-metal contact of the plate outer diameter with the inner diameter of the plate carrier, coupled with precision contact points of the plate carrier to the fitting affords users consistent compliance with AGA eccentricity requirements in vertical or horizontal plane. 1 The new plate carrier is compatible with Daniel Senior Orifice Fittings manufactured after To upgrade the plate carrier of your Senior Orifice Fitting, please contact your local Daniel representative. 3 1 Design Features 2 1. Precision ground corner tabs keep the orifice plate carrier in the proper position and allow the fitting to be mounted in the nine, twelve, or three o clock position. (See Figure 7) 2. Notched seal ring design provides metalto-metal contact for reliable alignment and centering of the orifice plate 3. The fitting s pin and the spring loaded button located at the top of the orifice plate carrier ensure tight positioning of the plate carrier when the slide valve is closed and the Senior Orifice Fitting is in the vertical or horizontal metering position Wide flow ports reduce differential pressure load across the plate surface 5. A 360 seal ring support shelf secures the plate in place 3 Nine O Clock (Far side) Twelve O Clock Three O Clock (Near side) Vertical Down Figure 7: Mounting Options Available 10

13 Differential Pressure Flow Meters Daniel Lubricant Daniel lubricant is specifically designed for lubricating the slide valve (1) of Senior Orifice Fittings, ensuring maximum operating performance. Because it is a chemical compound rather than a petroleum based product, this lubricant has significant advantages: Effective over a wide range of demanding temperatures (-40 to +500 F) and pressures (0 to 1,400 psig) Contains no fillers or inert materials, eliminating hardening or oxidizing Reduces friction and wear, extending equipment life in severe conditions Insoluble in water and extremely resistant to hydrocarbons within its temperature range Different types of lubricants are available to meet the various demanding needs of gas applications Daniel lubricant is available in B-sized sticks (3/8" diameter, 1.5" long) in 24-stick boxes. The cylinder shape (grease stick) fits neatly into the fitting s grease gun (Figure 8). Note Hard seat (using sealant / grease sticks) is standard on all Daniel Senior Orifice Fittings, providing an optimal seal in the production environment where fractionation sand and other particulate matter are common. Type 1 TEMPERATURE (F ) Type 2 PRESSURE ( PSIG) PRESSURE ( PSIG) 1,300 1,400 PSIG PSIG 200 PSIG 130 PSIG Technical Guide Lubricant Optimum Sealing Zones ,350 PSIG 135 PSIG 65 PSIG 115 PSIG TEMPERATURE (F ) Type 3 1,100 PSIG 1,000 PSIG PRESSURE ( PSIG) 200 PSIG 1,400 PSIG 750 PSIG 50 PSIG 75 PSIG 450 PSIG TEMPERATURE (F ) Type 4 PRESSURE ( PSIG) 1,400 PSIG 1100 PSIG 200 PSIG 90 PSIG 120 PSIG TEMPERATURE (F ) Soft seat (O-ring seal using no grease) is available in size 2" to 12" up to 600 ANSI for use with gas products such as ethylene. Stem Threaded Section Plunger Threaded Section of Grease Gun Body Fastened into Senior Fitting Top Lubricant Stick Grease Receiver-Body Internal Fluid Pressure Contained in the Fitting Grease Gun Body One-Way Check Valve Ball Figure 8: Grease Gun (1) Daniel slide valve / isolation mechanism does not comply with or adhere to API 598 valve criteria and does not guarantee zero leak seal. 11

14 Senior Orifice Fitting May 2013 Flangnek - Raised Face (1) 2" to 16" 150 to 900 ANSI (1) Double-ended operating shafts are standard. 12

15 Differential Pressure Flow Meters Technical Guide Minimum Clearance for Clamping Bar Removal Weight (lb) Orifice Plate Thickness Size of Drain Plugs (1) Diameter of Hub at Point of Welding Bolt Length of Bolts/ Studs with 2 Hex Nuts Flange Bolts / Studs Diameter Bolts / Studs per Flange Flange Thickness Height of Raised Face Diameter of Raised Face Diameter of Bolt Circle Diameter of Flange Clearance for Plate Changing Centerline to Top Clearance to Bottom Body Clearance from Center Operating Clearance from Center Overall Face to Face Downstream Face of Orifice Plate to Face of End Upstream Face of Orifice Plate to Face of End Diameter Internal Line Bore Standard Trim (2) SIZE A B C D F G H I I1 J K L M N O P R W Catalog No. 011-Daniel 2-16" Flangnek-Raised Face 150 ANSI NACE 2" * 5 5/16 5 5/ / /4 3 5/8 1/16 11/16 4 5/8 3 1/ /2 1/ NACE 3" * 6 15/ / / /16 7/8 4 5/8 3 3/ /2 1/ NACE 4" * 6 9/16 6 9/ / /2 6 3/16 1/16 7/8 8 5/8 3 3/ /4 1/ NACE 6" * 7 15/ / /2 8 1/2 1/16 15/16 8 3/ /4 1/ NACE 8" * 8 5/8 8 5/8 17 1/ /2 11 3/4 10 5/8 1/16 1 1/16 8 3/4 4 1/ /4 1/ A 10" * 6 3/8 6 3/ /4 12 3/4 1/16 1 1/8 12 7/8 4 3/ /4 1/ A 12" * 7 3/8 6 3/ /16 1 3/ /8 4 3/ /4 1/ A 14" * 7 3/8 7 3/ /4 16 1/4 1/16 1 5/ /8 5 1/ /4 1/ A 16" * 7 7/16 7 7/ / /2 24 1/4 18 1/2 1/16 1 7/ / /4 3/8 1, Catalog No. 013-Daniel 2-16" Flangnek-Raised Face 300 ANSI NACE 2" * 5 5/16 5 5/ / / /8 1/16 13/16 8 5/8 3 1/ /2 1/ NACE 3" * 6 15/ / /4 6 5/8 5 1/16 1 1/16 8 3/4 4 1/ /2 1/ NACE 4" * 6 9/16 6 9/ / /8 6 3/8 1/16 1 3/16 8 3/4 4 1/ /4 1/ NACE 6" * 7 15/ / /2 10 5/8 8 1/2 1/16 1 3/8 12 3/4 4 3/ /4 1/ NACE 8" * 8 5/8 8 5/8 17 1/ /8 1/16 1 9/ /8 5 1/ /4 1/ A 10" * 8 1/8 7 1/8 15 1/ /2 15 1/4 12 3/4 1/ / / /4 1/ A 12" * 8 7/8 7 7/ /2 17 3/4 15 1/ / /8 6 3/ /4 1/4 1, A 14" * 9 3/8 9 3/ /4 16 1/4 1/16 2 1/ / /4 1/4 1, A 16" * 8 5/16 7 7/ /2 22 1/2 18 1/2 1/16 2 3/ /4 7 3/ /4 3/8 1, Catalog No. 015-Daniel 2-16" Flangnek-Raised Face 600 ANSI NACE 2" * 5 5/16 5 5/ / /8 1/ /8 4 1/ /2 1/ NACE 3" * 6 15/ / /4 6 5/8 5 1/4 1 1/4 8 3/ /2 1/ NACE 4" * 6 9/16 6 9/ / /4 8 1/2 6 16/85 1/4 1 1/2 8 7/8 5 3/ /4 1/ NACE 6" * 7 15/ / /2 8 1/2 1/4 1 7/ / /4 1/ NACE 8" * 8 5/8 8 5/8 17 1/ /2 13 3/4 10 5/8 1/4 2 3/ /8 7 3/ /4 1/ A 10" * / /4 1/4 2 1/ /4 8 1/ /4 1/ A 12" * 9 13/ / / /4 15 1/4 2 5/ /4 8 3/ /4 1/4 1, A 14" * 10 1/4 10 1/4 20 1/ /4 20 3/4 16 1/4 1/4 2 3/ /8 9 1/ /4 1/4 1, A 16" * 10 5/8 10 5/8 21 5/ /4 18 1/2 1/ /2 10 1/ /4 3/8 2, Catalog No. 016-Daniel 2-16" Flangnek-Raised Face 900 ANSI (use PTFE Seal Ring or SSR only) A 2" * 6 15/ / /2 6 1/2 3 5/8 1/4 1 1/2 8 7/8 5 3/ /2 1/ A 3" * 6 15/ / /2 7 1/2 5 1/4 1 1/2 8 7/8 5 3/ /2 1/ A 4" * 7 13/16 7 1/ /2 9 1/4 6 16/85 1/4 1 3/ /8 6 3/ /4 1/ A 6" * 8 9/ / / /2 8 1/2 1/4 2 3/ /8 7 3/ /4 1/ A 8" * 9 1/16 9 1/ / /2 15 1/2 10 5/8 1/4 2 1/ /8 8 3/ /4 1/4 1, A 10" * 10 13/ / / /2 18 1/2 12 3/4 1/4 2 3/ /8 9 1/ /4 1/4 1, A 12" * 11 9/ / / /4 3 1/ / /4 1/4 1, A 14" * 11 1/ / / / /4 1/4 3 3/ /2 10 1/ /4 1/4 2, A 16" * 9 13/ / / /4 24 1/4 18 1/2 1/4 3 1/ / /4 3/8 CF 36 (1) Flanged process connections available. (2) Please consult Daniel factory or representative for other trims available for severe service and other code requirements, including low-temperature, high H 2 S, High CO 2, NORSOK, ISO 5167, PED, Daniel AASG, and special applications. 13

16 Senior Orifice Fitting May 2013 Flangnek - Ring Joint (1) 2" to 16" 600 ANSI and 2" to 16" 900 ANSI (1) Double-ended operating shafts are standard. 14

17 Differential Pressure Flow Meters Technical Guide Minimum Clearance for Clamping Bar Removal Weight (lb) Orifice Plate Thickness Size of Drain Plugs (1) Diameter of Hub at Point of Welding Length of Bolts / Studs with 2 Hex Nuts Diameter of Bolts / Studs per Flange Number of Bolts / Studs per Flange Flange Thickness Width of Groove Depth of Groove Pitch Diameter of Ring and Groove Diameter of Bolt Circle Diameter of Flange Clearance for Plate Changing Centerline to Top Clearance to Bottom Body Clearance from Center Operating Clearance from Center Overall Face to Face Downstream Face of Orifice Plate to Face of End Upstream Face of Orifice Plate to Face of End Diameter Internal Line Bore A.P.I. Ring Number Standard Trim (2) SIZE A B C D F G H I I1 J K L2 M1 M2 N1 O P R W Catalog No Daniel 2-16" Flangnek-Ring Joint 600 ANSI NACE 2" R-23 * 5 5/16 5 5/ / / /4 5/16 15/ /8 4 1/ /2 1/ NACE 3" R-31 * / /4 6 5/8 4 7/8 5/16 15/32 1 1/4 8 3/4 5 1/ /2 1/ NACE 4" R-37 * 6 5/8 6 5/8 13 3/ /4 8 1/2 5 7/8 5/16 15/32 1 1/2 8 7/ /4 1/ NACE 6" R-45 * / /2 8 5/16 5/16 15/32 1 7/ /4 1/ NACE 8" R-49 * 8 11/ / / /2 13 3/4 10 5/8 5/16 15/32 2 3/ / /4 1/ A 10" R-53 * 9 1/16 8 1/ / /4 5/16 15/32 2 1/ /4 8 3/ /4 1/ A 12" R-59 * 9 7/8 8 7/ /4 15 5/16 15/32 2 5/ / /4 1/4 1, A 14" R-61 * 10 5/ / / /4 20 3/4 16 1/2 5/16 15/32 2 3/ /8 9 3/ /4 1/4 1, A 16" R-65 * 10 11/ / / /4 18 1/2 5/16 15/ /2 10 1/ /4 3/8 2, Catalog No Daniel 2-16" Flangnek-Ring Joint 900 ANSI (use PTFE Seal Ring or SSR only) A 2" R-24 * / /2 6 1/2 3 3/4 5/16 15/32 1 1/2 8 7/ /2 1/ A 3" R-31 * / /2 7 1/2 4 7/8 5/16 15/32 1 1/2 8 7/ /2 1/ A 4" R-37 * 7 7/8 7 1/8 15 1/ /2 9 1/4 5 7/8 5/16 15/32 1 3/ / /4 1/ A 6" R-45 * 8 5/ / /2 8 5/16 5/16 15/32 2 3/ / /4 1/ A 8" R-49 * 9 1/8 9 1/8 18 1/ /2 15 1/2 10 5/8 5/16 15/32 2 1/ / /4 1/4 1, A 10" R-53 * 10 7/8 10 7/ /2 18 1/2 12 3/4 5/16 15/32 2 3/ /8 9 1/ /4 1/4 1, A 12" R-57 * 11 5/8 11 5/8 23 1/ /16 15/32 3 1/ /8 10 1/ /4 1/4 1, A 14" R-62 * 11 1/ /4 22 9/ / /2 7/16 21/32 3 3/ /2 10 1/ /4 1/4 2, A 16" R-66 * 9 13/ / /4 24 1/4 18 1/2 39/89 21/32 3 1/ / /4 3/8 CF 36 (1) Flanged process connections available. (2) Please consult Daniel factory or representative for other trims available for severe service and other code requirements, including low-temperature, high H 2 S, High CO 2, NORSOK, ISO 5167, PED, Daniel AASG, and special applications. 15

18 Senior Orifice Fitting May 2013 Flangnek - Raised Face (1) 2" to 16" 1500 ANSI and 2" to 12" 2500 ANSI (1) Double-ended operating shafts are standard. 16

19 Differential Pressure Flow Meters Technical Guide Minimum Clearance for Clamping Bar Removal Weight (lb) Orifice Plate Thickness Size of Drain Plugs (1) Diameter of Hub at Point of Welding Length of Bolts / Studs with 2 Hex Nuts Diameter of Bolts / Studs per Flange Number of Bolts / Studs per Flange Flange Thickness Height of Raised Face Diameter of Raised Face Diameter of Bolt Circle Diameter of Flange Clearance for Plate Changing Centerline to Top Clearance to Bottom Body Clearance from Center Operating Clearance from Center Overall Face to Face Downstream Face of Orifice Plate to Face of End Upstream Face of Orifice Plate to Face of End Diameter Internal Line Bore Standard Trim (2) SIZE A B C D F G H I I1 J K L M N O P R W Catalog No. 017-Daniel 2-16" Flangnek-Raised Face 1500 ANSI (use PTFE Seal Ring or SSR only) A 2" * 6 15/ / /2 6 1/ /4 1 1/2 8 7/8 5 3/ /4 1/ A 3" * 8 3/ / / /4 1 7/ / /4 1/ A 4" * 8 3/8 7 7/8 16 3/ /4 9 1/ /4 2 1/ /4 7 3/ /4 1/ A 6" * 10 3/4 10 3/ / /2 12 1/ /4 3 1/ /8 10 1/ /4 1/ A 8" * 11 23/ / / / /4 3 5/ /8 11 1/ /4 1/ A 10" * 12 5/ / / /4 4 1/ /8 13 1/ /4 1/ A 12" * 13 5/ / / /2 22 1/ /4 4 7/ / /4 1/4 2, A 14" * 10 15/ / / / /4 5 1/ / /4 1/4 CF 31 A 16" * 11 15/ / /2 27 3/ /4 5 3/ /2 17 1/ /4 3/8 CF 36 Catalog No Daniel 2-12" Flangnek-Raised Face 2500 ANSI (use PTFE Seal Ring or SSR only) A 2" * 8 5/8 8 5/8 17 3/ /4 6 3/ / /2 1/ A 3" * 9 9/16 9 9/ / /4 2 5/ /4 8 3/ /2 1/ A 4" * 10 1/2 10 1/2 21 1/ / / / /4 1/ A 6" * 12 1/2 12 1/2 25 1/ / /4 4 1/ / /4 1/8 1, A 8" * 19 9/ / / /4 17 1/ / /4 1/4 16 A 10" * 22 5/8 22 5/8 45 1/ /2 21 1/ /4 6 1/ /2 19 1/ /4 1/4 17 A 12" * 23 3/8 20 7/8 44 1/ / /4 7 1/ /4 21 1/ /4 1/4 17 (1) Flanged process connections available. (2) Please consult Daniel factory or representative for other trims available for severe service and other code requirements, including low-temperature, high H2S, High CO2, NORSOK, ISO 5167, PED, Daniel AASG, and special applications. 17

20 Senior Orifice Fitting May 2013 Flangnek - Ring Joint (1) 2" to 16" 1500 ANSI and 2" to 12" 2500 ANSI (1) Double-ended operating shafts are standard. 18

21 Differential Pressure Flow Meters Technical Guide Minimum Clearance for Clamping Bar Removal Weight (lb) Orifice Plate Thickness Size of Drain Plugs (1) Diameter of Hub at Point of Welding Length of Bolts / Studs with 2 Hex Nuts Diameter of Flange Bolts / Studs Number of Bolts / Studs per Flange Flange Thickness Width of Groove Depth of Groove Pitch Diameter of Ring and Groove Diameter of Bolt Circle Diameter of Flange Clearance for Plate Changing Centerline to Top Clearance to Bottom Body Clearance from Center Operating Clearance from Center Overall Face to Face Downstream Face of Orifice Plate to Face of End Upstream Face of Orifice Plate to Face of End Diameter Internal Line Bore A.P.I. Ring Number Standard Trim (2) SIZE A B C D F G H I I1 J K L2 M1 M2 N1 O P R W Catalog No Daniel 2-16" Flangnek-Ring Joint 1500 ANSI (use T PTFE Seal Ring or SSR only) A 2 R-24 * / /2 6 1/2 3 3/4 5/16 15/32 1 1/2 8 7/ /8 1/ A 3 R-35 * 8 1/4 7 3/4 16 1/ / /8 5/16 15/32 1 7/ /8 7 1/ /2 1/ A 4 R-39 * 8 7/ / / /4 9 1/2 6 3/8 5/16 15/32 2 1/ / /4 1/ A 6 R-46 * 10 7/8 10 5/ / /2 12 1/2 8 5/16 3/8 17/32 3 1/ /8 10 1/ /4 1/ A 8 R-50 * 11 29/ / / /2 10 5/8 7/16 21/32 3 5/ / /4 1/4 1, A 10 R-54 * 12 1/2 12 1/2 25 1/ /4 7/16 21/32 4 1/ /8 13 3/ /4 1/4 1, A 12 R-58 * 13 5/8 13 5/8 27 1/ /2 22 1/2 15 9/16 29/32 4 7/ / /4 1/4 2, A 14 R-63 * 10 15/ / / / /2 5/8 1 1/16 5 1/ /8 15 3/ /4 1/4 CF 31 A 16 R-67 * 11 15/ /8 29 7/ /2 27 3/4 18 1/2 11/16 1 3/16 5 3/ /2 17 1/ /4 3/8 CF 36 Catalog No Daniel 2-12" Flangnek-Ring Joint 2500 ANSI (3) (use SSR only) A 2 R-26 * 8 11/ / / /4 6 3/4 4 5/16 15/ / /2 1/ A 3 R-32 * 9 11/ / / /8 17/32 2 5/ / /2 1/ A 4 R-38 * 10 11/ / / /4 6 3/16 7/16 21/ /2 10 1/ /4 1/ A 6 R-47 * 12 7/ / / /2 9 1/2 25/32 4 1/ / /4 1/8 1, A 8 R-51 * 19 7/8 19 7/ /4 17 1/4 11 9/16 29/ / /4 1/4 16 A 10 R-55 * 23 1/ /8 44 3/ /2 21 1/4 13 1/2 11/16 1 3/16 6 1/ / /4 1/4 17 A 12 R60 * 23 13/ / / / /16 1 5/16 7 1/ / /4 1/4 17 (1) Flanged process connections available. (2) Please consult Daniel factory or representative for other trims available for severe service and other code requirements, including low-temperature, high H 2 S, High CO 2, NORSOK, ISO 5167, PED, Daniel AASG, and special applications. (3) 2500 ANSI Senior Orifice Fittings are available up to 12".Consult factory for larger line sizes. 19

22 Senior Orifice Fitting May 2013 Flanged - Raised Face (1) 10" to 16" 150 to 600 ANSI 2" to 16" 900 ANSI (1) Double-ended operating shafts are standard. 20

23 Differential Pressure Flow Meters Technical Guide Minimum Clearance for Clamping Bar Removal Weight (lb) Orifice Plate Thickness Size of Drain Plugs (1) Length of Bolts / Studs with 2 Hex Nuts Diameter of Flange Bolts/Studs Number of Bolts / Studs per Flange Flange Thickness Height of Raised Face Diameter of Raised Face Diameter of Bolt Circle Diameter of Flange Clearance for Plate Changing Centerline to Top Clearance to Bottom Body Clearance from Center Operating Clearance from Center Overall Face to Face Downstream Face of Orifice Plate to Face of End Upstream Face of Orifice Plate to Face of End Diameter Internal Line Bore Standard Trim (2) SIZE A B C D F G H I I1 J K L M N P R W Catalog No. 101-Daniel 10-16" Flanged-Raised Face 150 ANSI A 10" * 6 3/8 6 3/ / /4 12 3/4 1/16 1 1/8 12 7/8 4 3/4 3/4 1/ A 12" * 7 3/8 6 3/ /16 1 3/ /8 4 3/4 3/4 1/ A 14" * 7 3/8 7 3/ / /4 16 1/4 1/16 1 5/ /2 3/4 1/4 1, A 16" * 8 3/16 7 7/ /2 23 1/2 21 1/4 18 1/2 1/16 1 7/ /2 3/4 3/8 1, Catalog No. 103-Daniel 10-16" Flanged-Raised Face 300 ANSI A 10" * 8 1/8 7 1/8 15 1/ /8 17 1/2 15 1/4 12 3/4 1/ / /4 3/4 1/ A 12" * 8 7/8 7 7/ /2 17 3/4 15 1/ / /8 6 3/4 3/4 1/4 1, A 14" * 9 3/8 9 3/ / /4 16 1/4 1/16 2 1/ /8 7 3/4 1/4 1, A 16" * 9 1/16 8 5/ / /2 25 1/2 22 1/2 18 1/2 1/16 2 3/ /4 7 3/4 3/4 3/8 1, Catalog No. 105-Daniel 10-16" Flanged-Raised Face 600 ANSI A 10" * / / /4 1/4 2 1/ /4 8 1/2 3/4 1/ A 12" * 9 13/16 8 1/ / /4 15 1/4 2 5/ /4 8 3/4 3/4 1/4 1, A 14" * 10 1/4 10 1/2 20 3/ / /4 20 3/4 16 1/4 1/4 2 3/ /8 9 1/2 3/4 1/4 1, A 16" * 10 5/8 10 5/8 21 5/ / /4 18 1/2 1/ /2 10 1/4 3/4 3/8 2, Catalog No. 106-Daniel 2-16" Flanged-Raised Face 900 ANSI (use PTFE Seal Ring or SSR only) A 2" * 6 15/ / /16 8 1/2 6 1/2 3 5/8 1/4 1 1/2 8 7/8 5 3/4 1/2 1/ A 3" * 6 15/ / /16 9 1/2 7 1/2 5 1/4 1 1/2 8 7/8 5 3/4 1/2 1/ A 4" * 7 13/16 7 1/ /2 9 1/4 6 3/16 1/4 1 3/ /8 6 3/4 3/4 1/ A 6" * 8 9/ / / /2 8 1/2 1/4 2 3/ /8 7 3/4 3/4 1/ A 8" * 9 1/16 9 1/ / /2 15 1/2 10 5/8 1/4 2 1/ /8 8 3/4 3/4 1/4 1, A 10" * 10 13/ / / /8 21 1/2 18 1/2 12 3/4 1/4 2 3/ /8 9 1/4 3/4 1/4 1, A 12" * 11 9/ / / /4 3 1/ /8 10 3/4 1/4 2, A 14" * 11 1/ / / / / /4 1/4 3 3/ /2 10 1/2 3/4 1/4 2, A 16" * 12 11/ / / /2 27 3/4 24 1/4 18 1/2 1/4 3 1/ /4 11 3/4 3/8 4, (1) Flanged process connections available. (2) Please consult Daniel factory or representative for other trims available for severe service and other code requirements, including low-temperature, high H 2 S, High CO 2, NORSOK, ISO 5167, PED, Daniel AASG, and special applications. 21

24 Senior Orifice Fitting May 2013 Flanged - Raised Face (1) 2" to 8" 150 to 600 ANSI (1) Double-ended operating shafts are standard. 22

25 Differential Pressure Flow Meters Technical Guide Minimum Clearance for Clamping Bar Removal Weight (lb) Orifice Plate Thickness Size of Drain Plugs (1) Length of Bolts / Studs with 2 Hex Nuts Diameter of Flange Bolts / Studs Number of Bolts / Studs per Flange Flange Thickness Height of Raised Face Diameter of Raised Face Diameter of Bolt Circle Diameter of Flange Clearance for Plate Changing Centerline to Top Clearance to Bottom Body Clearance from Center Operating Clearance from Center Overall Face to Face (2) Downstream Face of Orifice Plate to Face of End (2) Upstream Face of Orifice Plate to Face of End Diameter Internal Line Bore Standard Trim (3) SIZE A B C D F G H I I1 J K L M N P R W Catalog No. 101-Daniel 2-8" Flanged-Raised Face 150 ANSI NACE 2" * 7 13/16 5 5/ / / /4 3 5/8 1/16 11/16 4 5/8 3 1/4 1/2 1/ NACE 3" * 11 3/8 5 3/8 16 3/ /16 7 1/ /16 7/8 4 5/8 3 3/4 1/2 1/ NACE 4" * 10 3/8 5 1/2 16 1/ /2 6 3/16 1/16 7/8 8 5/8 3 3/4 3/4 1/ NACE 6" * 13 7/8 5 5/8 19 1/ /2 8 1/2 1/16 15/16 8 3/4 4 3/4 1/ NACE 8" * 15 1/4 6 1/4 21 1/ /2 11 3/4 10 5/8 1/16 1 1/16 8 3/4 4 1/4 3/4 1/ Catalog No. 103-Daniel 2-8" Flanged-Raised Face 300 ANSI NACE 2" * 8 1/16 5 5/ / /16 6 1/ /8 1/16 13/16 8 5/8 3 1/2 1/2 1/ NACE 3" * 11 9/16 5 9/ / /16 8 1/4 6 5/8 5 1/16 1 1/16 8 3/4 4 1/4 1/2 1/ NACE 4" * 10 15/ / / /8 6 3/16 1/16 1 3/16 8 3/4 4 1/2 3/4 1/ NACE 6" * 12 7/ / /2 10 5/8 8 1/2 1/16 1 3/8 12 3/4 5 3/4 1/ NACE 8" * 14 1/ / /8 1/16 1 9/ /8 5 1/2 3/4 1/ Catalog No. 105-Daniel 2-8" Flanged-Raised Face 600 ANSI NACE 2" * 8 7/16 5 5/ / / /8 1/ /8 4 1/4 1/2 1/ NACE 3" * 10 1/ / /16 8 1/4 6 5/8 5 1/4 1 1/4 8 3/4 5 1/2 1/ NACE 4" * 10 7/8 6 5/8 17 1/ /4 8 1/2 6 3/16 1/4 1 1/2 8 7/8 5 3/4 3/4 1/ NACE 6" * 12 7/ / /2 8 1/2 1/4 1 7/ /4 3/4 1/ NACE 8" * 14 1/4 8 3/ /2 13 3/4 10 5/8 1/4 2 3/ /8 7 3/4 3/4 1/ (1) Flanged process connections available. (2) The flange-by-flange (F x F) configuration of the 2" to 8" Senior Orifice Fittings has changed. This change applies to ANSI classes 150 to 600 only. The flange-by-flange configuration has been replaced with a raised-face or ring-type-joint Flangnek (RFFN or RTJ FN) configuration featuring a flange welded to the upstream side (inlet)of the Flangnek fitting. This means the face-to-face dimensions are longer than previous versions and will not retrofit into the void of any old style F x F Senior Orifice Fitting purchased prior to August To replace discontinued F x F models, existing piping must be modified to accommodate the added length. (3) Please consult Daniel factory or representative for other trims available for severe service and other code requirements, including low-temperature, high H 2 S, High CO 2, NORSOK, ISO 5167, PED, Daniel AASG, and special applications. 23

26 Senior Orifice Fitting May 2013 Flanged - Ring Joint (1) 10" to 16" 600 and 2" to 16" 900 ANSI (1) Double-ended operating shafts are standard. 24

27 Differential Pressure Flow Meters Technical Guide Minimum Clearance for Clamping Bar Removal Weight (lb) Orifice Plate Thickness Size of Drain Plugs (1) Length of Bolts / Studs with 2 Hex Nuts Diameter Flange Bolt / Studs Number of Bolt / Studs per Flange Flange Thickness Width of Groove Depth of Groove Pitch Diameter of Ring and Groove Diameter of Bolt Circle Diameter of Flange Clearance for Plate Changing Centerline to Top Clearance to Bottom Body Clearance from Center Operating Clearance from Center Overall Face to Face Downstream Face of Orifice Plate to Face of End Upstream Face of Orifice Plate to Face of End Diameter Internal Line Bore A.P.I. Ring Number Standard Trim (2) SIZE A B C D F G H I I1 J K L2 M1 M2 N1 P R W Catalog No. 145-Daniel 10-16" Flanged-Ring Joint 600 ANSI A 10" R-53 * 9 9/16 8 1/ / /4 5/16 15/32 2 1/ /4 8 3/4 3/4 1/ A 12" R-57 * 9 7/8 8 7/ /4 15 5/16 15/32 2 5/ /4 9 3/4 1/4 1, A 14" R-61 * 10 5/ / / /4 20 3/4 16 1/2 5/16 15/32 2 3/ /8 9 3/4 3/4 1/4 1, A 16" R-65 * 10 11/ / / /4 18 1/2 5/16 15/ /2 10 1/2 3/8 3/8 2, Catalog No. 146-Daniel 2-16" Flanged-Ring Joint 900 ANSI (use PTFE Seal Ring or SSR only) A 2" R-24 * / /2 6 1/2 3 3/4 5/16 15/32 1 1/2 8 7/8 6 1/2 1/ A 3" R-31 * / /2 7 1/2 4 7/8 5/16 15/32 1 1/2 8 7/8 6 1/2 1/ A 4" R-37 * 7 7/8 7 1/8 15 1/ /2 9 1/4 5 7/8 5/16 15/32 1 3/ /8 7 3/4 1/ A 6" R-45 * 8 5/ / /2 8 5/16 5/16 15/32 2 3/ /8 8 3/4 1/ A 8" R-49 * 9 1/8 9 1/8 18 1/ /2 15 1/2 10 5/8 5/16 15/32 2 1/ /8 9 3/4 1/4 1, A 10" R-53 * 10 7/8 10 7/ /2 18 1/2 12 3/4 5/16 15/32 2 3/ /8 9 1/2 3/4 1/4 1, A 12" R-57 * 11 5/8 11 5/8 23 1/ /16 15/32 3 1/ /8 10 1/4 3/4 1/4 2, A 14" R-62 * / / / /2 7/16 15/32 3 3/ /2 10 1/2 3/4 1/4 2, A 16" R-66 * 12 13/ / /4 24 1/4 18 1/2 7/16 21/32 3 1/ /4 11 3/4 3/8 4, (1) Flanged process connections available. (2) Please consult Daniel factory or representative for other trims available for severe service and other code requirements, including low-temperature, high H 2 S, High CO 2, NORSOK, ISO 5167, PED, Daniel AASG, and special applications. 25

28 Senior Orifice Fitting May 2013 Flanged - Ring Joint (1) 2" to 8" 600 ANSI (1) Double-ended operating shafts are standard. 26

29 Differential Pressure Flow Meters Technical Guide Minimum Clearance for Clamping Bar Removal Weight (lb) Orifice Plate Thickness Size of Drain Plugs (1) Length of Bolts / Studs with 2 Hex Nuts Diameter Flange Bolt / Studs Number of Bolt / Studs per Flange Flange Thickness Width of Groove Depth of Groove Pitch Diameter of Ring and Groove Diameter of Bolt Circle Diameter of Flange Clearance for Plate Changing Centerline to Top Clearance to Bottom Body Clearance from Center Operating Clearance from Center Overall Face to Face (2) Downstream Face of Orifice Plate to Face of End (2) Upstream Face of Orifice Plate to Face of End Diameter Internal Line Bore A.P.I. Ring Number Standard Trim (3) SIZE A B C D F G H I I1 J K L2 M1 M2 N1 P R W Catalog No. 145-Daniel 2-8" Flanged-Ring Joint 600 ANSI NACE 2" R-23 * 8 1/2 5 5/ / / /4 5/16 15/ /8 4 1/2 1/2 1/ NACE 3" R-31 * 10 9/ / /4 6 5/8 4 7/8 5/16 15/32 1 1/4 8 3/4 5 1/4 1/2 1/ NACE 4" R-37 * 10 15/16 6 5/ / /4 8 1/2 5 7/8 5/16 15/32 1 1/2 8 7/8 6 3/4 1/ NACE 6" R-45 * 12 15/ / /2 8 5/16 5/16 15/32 1 7/ /4 1/ NACE 8" R-49 * 14 3/16 8 3/4 23 3/ /2 13 3/4 10 5/8 5/16 15/32 2 3/ /8 8 3/4 1/ (1) Flanged process connections available. (2) The flange-by-flange (F x F) configuration of the 2" to 8" Senior Orifice Fittings has changed. This change applies to ANSI classes 150 to 600 only. The flange-by-flange configuration has been replaced with a raised-face or ring-type-joint Flangnek (RFFN or RTJ FN) configuration featuring a flange welded to the upstream side (inlet)of the Flangnek fitting. This means the face-to-face dimensions are longer than previous versions and will not retrofit into the void of any old style F x F Senior Orifice Fitting purchased prior to August To replace discontinued F x F models, existing piping must be modified to accommodate the added length. (3) Please consult Daniel factory or representative for other trims available for severe service and other code requirements, including low-temperature, high H 2 S, High CO 2, NORSOK, ISO 5167, PED, Daniel AASG, and special applications. 27

30 Senior Orifice Fitting May 2013 Flanged - Raised Face (1) 2" to 16" 1500 ANSI and 2" to 12" 2500 ANSI (1) Double-ended operating shafts are standard. 28

31 Differential Pressure Flow Meters Technical Guide Minimum Clearance for Clamping Bar Removal Weight (lb) Orifice Plate Thickness Size of Drain Plugs (1) Length of Bolts / Studs with 2 Hex Nuts Diameter of Flange Bolts / Studs Number of Bolts / Studs per Flange Flange Thickness Height of Raised Face Diameter of Raised Face Diameter of Bolt Circle Diameter of Flange Clearance for Plate Changing Centerline to Top Clearance to Bottom Body Clearance from Center Operating Clearance from Center Overall Face to Face Downstream Face of Orifice Plate to Face of End Upstream Face of Orifice Plate to Face of End Diameter Internal Line Bore Standard Trim (2) SIZE A B C D F G H I I1 J K L M N P R W Catalog No. 107-Daniel 2-16" Flanged-Raised Face 1500 ANSI (use PTFE Seal Ring or SSR only) A 2" * 6 15/ / /2 6 1/2 3 5/8 1/4 1 1/2 8 7/8 5 3/4 1/2 1/ A 3" * 8 3/ / / /4 1 7/ /8 7 1/2 1/ A 4" * 8 3/8 7 7/8 16 3/ /4 9 1/2 6 3/16 1/4 2 1/ /4 7 3/4 3/4 1/ A 6" * 10 3/4 10 3/ / /2 12 1/2 8 1/2 1/4 3 1/ /8 10 1/4 3/4 1/ A 8" * 11 23/ / / /2 10 5/8 1/4 3 5/ /8 11 1/2 3/4 1/4 1, A 10" * 12 5/ / / /4 1/4 4 1/ /8 13 1/2 3/4 1/4 2, A 12" * 13 5/ / / /2 22 1/2 15 1/4 4 7/ /4 3/4 1/4 3, A 14" * 10 15/ / / / /4 1/4 5 1/ /4 16 3/4 1/4 CF 31 A 16" * 16 7/ / / /2 27 3/4 18 1/2 1/4 5 3/ /2 17 1/2 3/4 3/8 CF 36 Catalog No. 108-Daniel 2-12" Flanged-Raised Face 2500 ANSI (use SNC only) A 2" * 8 5/8 8 5/8 17 3/ /4 6 3/4 3 5/8 1/ /2 1/ A 3" * 9 9/16 9 9/ / /4 2 5/ /4 8 3/4 1/2 1/ A 4" * 10 1/2 10 1/2 21 1/ /4 6 3/16 1/ /2 10 3/4 1/ A 6" * 12 1/2 12 1/2 25 1/ /2 8 1/2 1/4 4 1/ /4 3/4 1/8 1, A 8" * 19 9/ / / /4 17 1/4 10 5/8 1/ /4 1/4 16 A 10" * 22 5/8 22 5/8 45 1/ /2 21 1/4 12 3/4 1/4 6 1/ /2 19 1/4 3/4 1/4 17 A 12" * 23 3/8 23 3/ /8 15 1/4 7 1/ /4 21 1/4 3/4 1/4 17 (1) Flanged process connections available. (2) Please consult Daniel factory or representative for other trims available for severe service and other code requirements, including low-temperature, high H 2 S, High CO 2, NORSOK, ISO 5167, PED, Daniel AASG, and special applications. 29

32 Senior Orifice Fitting May 2013 Flanged - Ring Joint (1) 2" to 16" 1500 ANSI and 2" to 12" 2500 ANSI (1) Double-ended operating shafts are standard. 30

33 Differential Pressure Flow Meters Technical Guide Minimum Clearance for Clamping Bar Removal Weight (lb) Orifice Plate Thickness Size of Drain Plugs (1) Length of Bolts / Studs with 2 Hex Nuts Diameter of Flange Bolts / Studs Number Of Bolts / Studs per Flange Flange Thickness Width of Groove Depth of Groove Pitch Diameter of Ring and Groove Diameter of Bolt Circle Diameter of Flange Clearance for Plate Changing Centerline to Top Clearance to Bottom Body Clearance from Center Operating Clearance from Center Overall Face to Face Downstream Face of Orifice Plate to Face of End Upstream Face of Orifice Plate to Face of End Diameter Internal Line Bore A.P.I. Ring Number Standard Trim (2) SIZE A B C D F G H I I1 J K L2 M1 M2 N1 P R W Catalog No. 147-Daniel 2-16" Flanged-Ring Joint1500 ANSI (use PTFE Seal Ring or SSR only) A 2" R-24 * / /2 6 1/2 3 3/4 5/16 15/32 1 1/2 8 7/8 6 1/2 1/ A 3" R-35 * 8 1/4 7 3/4 16 1/ / /8 5/16 15/32 1 7/ /8 7 1/4 1/2 1/ A 4" R-39 * 8 7/ / / /4 9 1/2 6 3/8 5/16 15/32 2 1/ /4 8 3/4 1/ A 6" R-46 * 10 7/8 10 5/ / /2 12 1/2 8 5/16 3/8 17/32 3 1/ /8 10 1/2 3/4 1/ A 8" R-50 * 11 29/ / / /2 10 5/8 7/16 21/32 3 5/ /8 12 3/4 1/4 1, A 10" R-54 * 12 1/2 12 1/2 25 1/ /4 7/16 21/32 4 1/ /8 13 3/4 3/4 1/4 2, A 12" R-58 * 13 5/8 13 5/8 27 1/ /2 22 1/2 15 9/16 29/32 4 7/ /4 3/4 1/4 3, A 14" R-63 * 10 15/ / / / /4 5/8 1 1/16 5 1/ /8 15 3/4 3/4 1/4 CF 31 A 16" R-67 * 17 1/8 17 1/8 34 5/ /2 27 3/4 18 1/2 64/93 1 3/16 5 3/ /2 17 1/4 3/4 3/8 CF 36 Catalog No. 148-Daniel 2-12" Flanged-Ring Joint 2500 ANSI (use SNC only) A 2" R-26 * 8 11/ / / /4 6 3/4 4 5/16 15/ /4 1/2 1/ A 3" R-32 * 9 11/ / / /8 17/32 2 5/ /4 9 1/2 1/ A 4" R-38 * 10 11/ / / /4 6 3/16 7/16 21/ /2 10 1/2 3/4 1/ A 6" R-47 * 12 3/4 12 3/4 25 5/ /2 9 1/2 25/32 4 1/ /4 3/4 1/8 1, A 8" R-51 * 19 7/8 19 7/ /4 17 1/4 11 9/16 29/ /2 3/4 1/4 16 A 10" R-55 * 23 1/ / / /2 21 1/4 13 1/2 11/16 1 3/16 6 1/ /2 20 3/4 1/4 17 A 12" R-60 * 23 13/ / / / /16 1 5/16 7 1/ /4 22 3/4 1/4 17 (1) Flanged process connections available. (2) Please consult Daniel factory or representative for other trims available for severe service and other code requirements, including low-temperature, high H 2 S, High CO 2, NORSOK, ISO 5167, PED, Daniel AASG, and special applications. 31

34 Senior Orifice Fitting May 2013 Daniel TM Senior TM Orifice Fitting Selection Matrix BASIC TYPE / PRIMARY FUNCTION Nominal line size 6" Internal diameter Fitting Style Raised Face Flangnek 01 Raised Face Flanged 10 Ring Joint Flangnek 014 Ring Joint Flanged 14 ANSI 150# 1 300# 3 600# 5 900# # # 8 6 Orifice Plate Seals Removable Dual Seal*(up to 12") Dual Volcanized Seal*(16" and up) Removable PTFE Seal (up to 24") Removable Metal Seal (up to 24") Removable Snap Seal*(up to 20") DSC 3DVS TSC MSC SNC Internal trim material Standard Sour Gas / Corrosive Service NACE (standard 2" to 8") ANSI A AASG NACE When ordering, please specify: Catalog Number, Plate Material, Plate Bore(s) and Quantity. Note: All products and components are subject to change without notice in a continuing effort of product improvement. 32

35

36 Emerson Process Management Daniel Measurement and Control, Inc. North America / Latin America: Headquarters USA - Houston, Texas T USA Toll Free FLOW Europe: Stirling, Scotland, UK T Middle East, Africa: Dubai, UAE T Asia Pacific: Singapore T Scan with your smart phone for more information 2013 Daniel Measurement and Control, Inc. All Rights Reserved. Unauthorized duplication in whole or in part is prohibited. Printed in the USA. DAN-SOF-TECH-GUIDE-0513 Daniel Measurement and Control, Inc. ( Daniel ) is an Emerson Process Management business unit. The Daniel name and logo are trademarks of Daniel Industries, Inc. The Emerson logo is a trademark and service mark of Emerson Electric Co. Parker is a trademark of Parker Hannifin Corporation.

Features: Quality Testing and Documentation

Features: Quality Testing and Documentation 1 The Yokogawa Falcon Series Dual Chamber Orifice Assembly YFOM-DC, is suitably designed for on-line retraction and inspection of orifice plates in process full flow and pressure conditions. The orifice

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual 00809-0100-4828, Rev BA Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before

More information

Vonk Choke Valve. Flow Control. Features and benefits. Product overview. Technical data. General applications. Model YCV (Y-Type body)

Vonk Choke Valve. Flow Control. Features and benefits. Product overview. Technical data. General applications. Model YCV (Y-Type body) Flow Control Vonk choke valves provide superior performance in abrasive environments, precise flow control and ease of maintenance, delivering operational reliability in the most challenging applications.

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe

More information

98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98

98 Series Back Pressure. Valve Link. Features. Fisher Controls. August 1993 Bulletin 71.4:98 Series Back Pressure and Type Relief VL000 Valves FIELDVUE Valve Link Fisher Controls August Bulletin.: The Series (figure ) is used for back pressure or relief applications in liquid, gas, air, and steam

More information

Choke Valves SINCE1958. Unique. Precise. Quality. Reliable.

Choke Valves SINCE1958. Unique. Precise. Quality. Reliable. SINCE198 MDI / MDIS Choke Valves Unique. Precise. Quality. Reliable. MDI / MDIS SERIES CHOKE VALVES FEATURES Benefits T aylor Valve MDI / MDIS Series Chokes are made with wear resistant material to extend

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Reference Manual Rosemount 1595 Conditioning Orifice Plate www.rosemount.com Reference Manual Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate NOTICE Read this manual before working with the product.

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Rosemount 1595 Conditioning Orifice Plate Ordering information Rosemount 1595 Conditioning Orifice combines a flow conditioner with an orifice plate into a highly accurate primary element. Requires only

More information

Taylor Valve Technology, Inc

Taylor Valve Technology, Inc MULTI-ORIFICE VALVE MD SERIES PRODUCTION CHOKES Gas Lift Water Injection Enhanced Oil Recovery Throttling Valve High DP Valve Motor Operated Valve Manual and Automated Applications JUL0-TVT-OKC SERIES

More information

Taylor Valve Technology, Inc

Taylor Valve Technology, Inc MULTI-ORIFICE VALVE Taylor Valve MD SERIES PRODUCTION CHOKES Gas Lift Water Injection Enhanced Oil Recovery Throttling Valve High DP Valve Motor Operated Valve Manual and Automated Applications JAN00-TVT-OKC

More information

Choke Valves SINCE1958. Unique. Precise. Quality. Reliable.

Choke Valves SINCE1958. Unique. Precise. Quality. Reliable. SINCE95 MC SERIES Choke Valves Unique. Precise. Quality. Reliable. MOV Valve Principle of Operation Taylor Valve Technology Multi-Orifice Valve Design Principle Provides Precision Control. The two adjacent

More information

SHORT PATTERN FLANGE BALL VALVES 5000 SERIES

SHORT PATTERN FLANGE BALL VALVES 5000 SERIES SHORT PATTERN FLANGE BALL VALVES 5000 SERIES Jarecki 5000 Series metal seated ball valves with the Phantom Port incorporate the most innovative design in ball valves today. Proven in the field, they provide

More information

Inch / Cross Type Metric Section Style Material Page. Inch Deep Style 92 Durometer Urethane with 70 Durometer Nitrile Energizer

Inch / Cross Type Metric Section Style Material Page. Inch Deep Style 92 Durometer Urethane with 70 Durometer Nitrile Energizer Hydraulic Seals Inch / Cross Type Metric Section Style Material Page Standard 92 Durometer Urethane 7-11 with 70 Durometer Nitrile Energizer Inch Deep Style 92 Durometer Urethane 12-16 with 70 Durometer

More information

Rosemount 1595 Conditioning Orifice Plate

Rosemount 1595 Conditioning Orifice Plate Product Data Sheet Rosemount 1595 Rosemount 1595 Conditioning Orifice Plate Designed to provide superior performance in short straight pipe run applications Requires only two diameters of straight pipe

More information

Choke Valves SINCE1958. Unique. Precise. Quality. Reliable.

Choke Valves SINCE1958. Unique. Precise. Quality. Reliable. SINCE1958 MDA / MDAS Choke Valves Unique. Precise. Quality. Reliable. MDA / MDAS SERIES CHOKE VALVES FEATURES enefits T aylor Valve MDA / MDAS Series Chokes are made with wear resistant material to extend

More information

HOW TO ORDER SWIVEL JOINTS

HOW TO ORDER SWIVEL JOINTS HOW TO ORDER SWIVEL JOINTS Emco Wheaton offers a wide variety of swivel joints to fit almost any application. In order to assist you in ordering the Correct swivel joint, we have developed a guideline

More information

MultiPort Ball Valves

MultiPort Ball Valves Subsidiary of Bray International, Inc. Subsidiary of BRY INTERNTIONL, Inc. & WY Multi-Port Valves Full Port/Standard Port / - Ball Valves SME CL 0/00 (PN0 to PN 0) 00/000 psi WOG ( to 9 Bar) MultiPort

More information

Pig Valves Complete Solutions for Industrial Valves. jagflo.com

Pig Valves Complete Solutions for Industrial Valves. jagflo.com Pig Valves Complete Solutions for Industrial Valves Cat.no.:E-PV-00 Introduction ~ Quality Commitment How to Order Product Introduction Material Specifications Working Sequences Design Feature Dimensions

More information

Vonk Choke Valve. Flow Control. Features and benefits. Product overview. General applications. Technical data. Model CHV (Angle Body)

Vonk Choke Valve. Flow Control. Features and benefits. Product overview. General applications. Technical data. Model CHV (Angle Body) Vonk hoke Valve Model HV (ngle ody) Flow ontrol Vonk choke valves provide superior performance in abrasive environments, precise flow control and ease of maintenance, delivering operational reliability

More information

CHECK VALVE CH-1601A (EN)

CHECK VALVE CH-1601A (EN) CH-1A (EN) ABOUT US FBV Inc. is an ISO 001 certified company specializing in manufacturing industrial valves including ball valves, gate valves, globe valves, check valves, plug valves and butterfly valves

More information

Type. Facts. 441, 442 Full nozzle DIN. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E

Type. Facts. 441, 442 Full nozzle DIN. Flanged Safety Relief Valves spring loaded. The-Safety-Valve.com. Metric Units LWN E Type 441, 442 DIN Flanged Safety Relief Valves spring loaded Metric Units Facts The-Safety-Valve.com LWN 468.01-E DIN, ANSI 40 Cap H2 19 Lock nut 18 Adjusting screw with bushing 16 Upper spring plate 12

More information

STEEL PIPE NIPPLES G1616 STANDARD BLACK STEEL NIPPLES ITEMS HIGHLIGHTED

STEEL PIPE NIPPLES G1616 STANDARD BLACK STEEL NIPPLES ITEMS HIGHLIGHTED STEEL PIPE NIPPLES Pipe PRICE Part No. Size Length EACH G1616 STANDARD BLACK STEEL NIPPLES G1616-0XC 1 8" Close $ 2.00 G1616-0X1.5 1 8" 1 1 2" 2.20 G1616-0X2 1 8" 2" 2.30 G1616-0X2.5 1 8" 2 1 2" 2.50 G1616-0X3

More information

VAREC 5000/5010 SERIES FLAME ARRESTERS

VAREC 5000/5010 SERIES FLAME ARRESTERS VAREC 000/00 SERIES FLAME ARRESTERS Group D end-of-line flame arresters with a unique extensible bank frame designed to stop the propagation of flame from external sources FEATURES 00 SERIES - HORIZONTAL

More information

Data is only for informational purpose. All specifications are subject to change without notice.

Data is only for informational purpose. All specifications are subject to change without notice. MV Data is only for informational purpose. All specifications are subject to change without notice. 1 First in knife gate 2018-12-19 solutions issue 24 Knife gate valve MV Stafsjö s knife gate valve MV

More information

The Canalta Single Chamber Orifice Fitting

The Canalta Single Chamber Orifice Fitting he Canalta Single Chamber rifice Fitting Exceptional Value means adding to your Bottom Line without sacrificing Quality, Service or Performance An IS 9001:2008 registered company Phone: 403.342.4494 Email:

More information

SV81H Safety and Relief Valve

SV81H Safety and Relief Valve Page TID BR Rev.0 UV SV8H Safety Relief Valve Description The SV8H have fied blowdown.no blowdown adjustment required when setting or testing the valve.it is designed for short blowdown on all medias.

More information

precision pipe fittings

precision pipe fittings Precision Pipe Fittings 1 8 to 1 sizes 316 stainless steel, brass, and exotic materials NPT threads HOKE Inc. PO Box 4866 Spartanburg, SC 29305-4866 Phone (864) 574-7966 Fax (864) 587-5608 www.hoke.com

More information

Assembly and Maintenance

Assembly and Maintenance Assembly and Maintenance Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines

More information

Chemlock PFA and PP Filter Housings

Chemlock PFA and PP Filter Housings CONTAMINATION CONTROL SOLUTIONS Chemlock PFA and PP Filter Housings Installation and use manual Table of Contents Introduction... 2 Safety... 2 Specifications... 2 PFA... 2 PP... 2 Dimensions... 3 Minimum

More information

Ultrasonic Flow Meter Brochure

Ultrasonic Flow Meter Brochure Ultrasonic Meter Brochure Rev. 2011/06/10 www.sitelab.us.com Descriptions SL1168 Ultrasonic meter uses the latest digital technology and low-voltage broadband pulse transmission. The instrument is tolerant

More information

LCC Pump Series - Wear Resistant, High Performance Slurry Pumps

LCC Pump Series - Wear Resistant, High Performance Slurry Pumps LCC Pump Series - Wear Resistant, High Performance Slurry Pumps 02 LCC Pump Series Solutions for the most Abrasive and Corrosive Slurry Applications With High Performance Wear Resistance, the GIW Minerals

More information

Product Bulletin BPS-100 Revision 2.1 November C l a m p P i p e C o n n e c t o r

Product Bulletin BPS-100 Revision 2.1 November C l a m p P i p e C o n n e c t o r Product Bulletin BPS-00 C l a m p P i p e C o n n e c t o r Table of Contents BlueSky Clamp Connector... Industrial Applications... Clamp Connector Description... How the Metal to Metal Seal Works... Design

More information

VAREC 2010B/2020B PRESSURE AND VACUUM RELIEF VALVES

VAREC 2010B/2020B PRESSURE AND VACUUM RELIEF VALVES VAREC 0B/B PRESSURE AND VACUUM RELIEF VALVES Weight-loaded relief valves that protect tanks from damage or deformation, minimize emissions to the environment and loss of product due to evaporation FEATURES

More information

Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators

Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators 657 and 667 Size 30i - 76i Product Bulletin August 2016 Fisher 657 and 667 Size 30i - 76i Diaphragm Actuators Fisher 657 and 667, size 30i to 76i, spring-opposed diaphragm actuators position the valve

More information

Pressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI

Pressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI Pressure reducing valve in straightway form NPS 1-6 Pressure reducing valve Pressure regulating valve, straight through with diaphragm actuator DMA Actuator with rolling diaphragm Cast steel Fig. 701 Page

More information

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION

TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION S6 USER S MANUAL TABLE OF CONTENTS SECTION 1 TABLETOP CONFIGURATION SECTION 2 TABLETOP CONFIGURATION ACCESSORIES SECTION 3 SLIDE CONFIGURATION SECTION 4 SLIDE CONFIGURATION ACCESSORIES SECTION 5 RACK MOUNT

More information

Quality Since 1935 SERIES EXPANSION JOINTS WON T

Quality Since 1935 SERIES EXPANSION JOINTS WON T 1-00-25-00 Quality Since 135 SERIES 0EZ EXPANSION JOINTS THEY PERFORM LIKE WON T YOU BELIEVE THE EVOLUTION OF ELASTOMERIC EXPANSION JOINT STYLES Standard Arch (The 130 s) Flowing Arch (The 170 s) Wide

More information

Standard Releasing Spear. Manual B215

Standard Releasing Spear. Manual B215 Standard Releasing Spear Manual B215 NOTES Contents Standard Releasing Spear Overview... 2 Use... 2 Construction... 2 Illustrations Spear Assembly with Flush-Type Mandrel... 3 Spear Assembly with Shoulder-Type

More information

Titan Media Cart. Installation and Operation Manual

Titan Media Cart. Installation and Operation Manual Titan Media Cart Installation and Operation Manual Table of Contents INTRODUCTION SERVICE AND SUPPORT... 1 PRODUCT RETURNS... 1 UNPACKING... 1 TITAN SINGLE MEDIA CART... 2 TITAN DUAL MEDIA CART... 2 BEFORE

More information

Pressure Test Pumps. Test Pump. Electric Test Pump. Assembly and Maintenance Test Pumps

Pressure Test Pumps. Test Pump. Electric Test Pump. Assembly and Maintenance Test Pumps Assembly and Maintenance Test Pumps Pressure Test Pumps Tests all types of installations such as heating, compressed air and refrigeration systems, oil installations, fire lines and small bore pipelines.

More information

PSI COMPAKT SEAL PRESSURE TIGHT UP TO 5 BAR SPECIAL VERSIONS FOR DIFFERENT PIPE SYSTEMS STAINLESS STEEL PRESSURE PLATES AS STANDARD

PSI COMPAKT SEAL PRESSURE TIGHT UP TO 5 BAR SPECIAL VERSIONS FOR DIFFERENT PIPE SYSTEMS STAINLESS STEEL PRESSURE PLATES AS STANDARD PSI COMPAKT SEAL PRESSURE TIGHT UP TO 5 BAR SPECIAL VERSIONS FOR DIFFERENT PIPE SYSTEMS STAINLESS STEEL PRESSURE PLATES AS STANDARD ALL SPLIT VERSIONS OF OUR STANDARD COMPAKT SEALS ARE FOLDABLE WWW.PSI-PRODUCTS.COM

More information

STANDARD GAGE ACTION CONTENT. 03 Calipers Depth Calipers Micrometers Depth Micrometers Tool Sets Dial Gauges...

STANDARD GAGE ACTION CONTENT. 03 Calipers Depth Calipers Micrometers Depth Micrometers Tool Sets Dial Gauges... STANDARD GAGE ACTION CONTENT 03 Calipers... 09 Depth Calipers... 12 Micrometers... 15 Depth Micrometers... 16 Tool Sets... 17 Dial Gauges... 18 Lever Indicators... 19 Caliper Gauges... 19 Dial Bore Gauges...

More information

Spray Nozzle Catalog A guide to spray nozzle selection

Spray Nozzle Catalog A guide to spray nozzle selection Spray Catalog A guide to spray nozzle selection A selection guide to nozzles that will optimize your showering applications. How to Use This Catalog How to identify, specify and order Kadant spray nozzles

More information

Flareless Bite Type Fittings

Flareless Bite Type Fittings Ferulok Flareless Bite Type Fittings Ferulok Flareless Bite Type Fittings 4300 atalog BU TU WLN HBU Nut Ferrules Bulkhead Locknut Union Nuts, Ferrules, Locknuts Straights 7 7 7 7 WBU F5BU FBU GBU TRBU

More information

Preparation and Installation of the Composite Type Rupture Disc (Light Lip and Heavy Lip) in 30 Seat Insert, Full-Bolted, and Union Type Holder

Preparation and Installation of the Composite Type Rupture Disc (Light Lip and Heavy Lip) in 30 Seat Insert, Full-Bolted, and Union Type Holder GEP-7004 Rev. L 101251 Ref. ID: 5472 Preparation and Installation of the Composite Type Rupture Disc (Light Lip and Heavy Lip) in 30 Seat Insert, Full-Bolted, and Union Type Holder WARNING USER SHOULD

More information

BARE SHAFT PUMPS AND MOTOR PUMPS

BARE SHAFT PUMPS AND MOTOR PUMPS APPLICATIONS Air Conditioning Heating and ventilation Refrigeration Fire protection Plumbing Water Circulation Transfer and Irrigation Pressure Boosting Process Industries Water Treatment and Supply DESIGN

More information

Item 620A Multi-Way Sanitary Ball Valve

Item 620A Multi-Way Sanitary Ball Valve R Item 0A Multi-Way Sanitary Ball Valve 00 WOG/ PN : /"-" SPECIFICATION * Body & end caps quality investment casting * Regulation (EC) No. / 00; (EU) 0/0 * Available in stainless steel or carbon steel

More information

Compact Bellows Pumps

Compact Bellows Pumps Compact Bellows Pumps Compact Bellows Metering Pumps were specifically designed for metering applications requiring low discharge pressures. Compact pumps have been successfully applied in photo, X-ray

More information

Pressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI

Pressure reducing valve. Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI Pressure reducing valve in straightway form NPS 1-6 ARI-PREDU - ANSI Pressure reducing valve ARI-PREDU - ANSI Pressure regulating valve, straight through with diaphragm actuator DMA Actuator with rolling

More information

Connections Catalog WIDEST SIZE RANGE ALL ALLOYS VAST INVENTORY QUICK TURNAROUND CAPABILITY AVL APPROVAL

Connections Catalog WIDEST SIZE RANGE ALL ALLOYS VAST INVENTORY QUICK TURNAROUND CAPABILITY AVL APPROVAL Connections Catalog WIDEST SIZE RANGE ALL ALLOYS VAST INVENTORY QUICK TURNAROUND CAPABILITY AVL APPROVAL CUSTOM SOLUTIONS GLOBAL AVAILABILITY BROAD PRODUCTION CAPABILITY FULL PRODUCT TESTING About AFGlobal

More information

Rexroth Linear Bushings and Shafts, GreenLight Selection

Rexroth Linear Bushings and Shafts, GreenLight Selection 4 Bosch Rexroth Corp. Linear Motion and Assembly Technologies Rexroth Linear Bushings and Shafts, GreenLight Selection Bosch Rexroth is the global leader in metric bushings. Whether you need standard bushings

More information

Standard Bellows Metering Pumps

Standard Bellows Metering Pumps Standard Bellows Metering Pumps Bellows Metering Pumps operate on a positive displacement principle. Pumps are designed to displace both corrosive and noncorrosive fluids. Accurate to ± 0.5% from stroke

More information

Excellent in separation of two different fluids under pressure Compact design and groove structure allow interchangability with the Hallite P54

Excellent in separation of two different fluids under pressure Compact design and groove structure allow interchangability with the Hallite P54 PISTON SEAL Double-Acting TECHNICAL DETAILS The Hallite GPS is a double-acting piston seal utilizing Hallite s high-performance Armorlene HLX PTFE paired with an elastomer energizer and x-ring for optimum

More information

Mini Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX:

Mini Bellows Pumps. 180 Hines Ave. Bellville, OH PH: FAX: Mini Bellows Pumps Mini Bellows models are ideal for low flow, low pressure metering applications. The pump is constructed entirely of plastic and utilizes GRI s time-proven bellows technology to provide

More information

Connectivity Products

Connectivity Products Cable Glands Strain Relief Snap-In Labels Lock Nuts Torque Wrench Protective Sleeves U2 U5 U5 U6 U7 U8 Features NPT and PG thread cable glands in nylon or metal materials Locknuts in multiple thread sizes

More information

We provide superior performing compressed air & gas systems with engineered longevity to reduce operating costs and improve productivity.

We provide superior performing compressed air & gas systems with engineered longevity to reduce operating costs and improve productivity. We provide superior performing compressed air & gas systems with engineered longevity to reduce operating costs and improve productivity. ENGINEERED FOR SUPERIOR PERFORMANCE Compressed Air & Gas Systems

More information

American Petroleum Institute Purchasing Guidelines Purchase API Spec 6A online at

American Petroleum Institute Purchasing Guidelines Purchase API Spec 6A online at API Specification 6A ISO 10423:2009 (Modified), Petroleum and natural gas industries Drilling and production equipment Wellhead and christmas tree equipment 20th Edition, October 2010 Specification for

More information

SMG VALVES A Unit of SOUTHERN MANUFACTURING GROUP, Inc. BULLETIN August 2009 PERMASEAL PLUG VALVES TECHNICAL SPECIFICATIONS

SMG VALVES A Unit of SOUTHERN MANUFACTURING GROUP, Inc. BULLETIN August 2009 PERMASEAL PLUG VALVES TECHNICAL SPECIFICATIONS SM VLVES Unit of SOUTHERN MNUTURIN ROUP, Inc. ULLETIN 13.01-02 ugust 2009 PERMSEL PLU VLVES TEHNIL SPEIITIONS SM VLVES Unit of SOUTHERN MNUTURIN ROUP, Inc. Materials of onstruction ody & over arbon Steel

More information

Parts and Service Manual IMCO

Parts and Service Manual IMCO XXTREME ADVANTAGE Gimbal Parts and Service Manual IMCO 510 East Arrow Highway San Dimas, CA 91773 (800) 899-8058 (909) 592-6162 Fax (909) 592-6052 www.imcomarine.com email info@imcomarine.com TABLE OF

More information

TURCK Industrial Connectivity Products

TURCK Industrial Connectivity Products TURCK Industrial Connectivity Products General Accessories Liquid Tight Strain Relief Cable Glands Lock Nuts Page R2 - R4 Page R6 Snap-in Labels Strain Relief Cord Grips Page R5 Page R5 Protective Sleeving

More information

Introduction. Available materials. Aluminum Carbon Steel Stainless Steel Ductile Iron Special Materials on Application

Introduction. Available materials. Aluminum Carbon Steel Stainless Steel Ductile Iron Special Materials on Application VALVES & CONTROLS VAREC 00B/00B The Varec 00B/00B protects tanks from damage or deformation, and minimizes emissions to the environment, as well as loss of product due to evaporation. Introduction 00B

More information

Model RFM. Model RFM. Materials and Specifications. Residential Fire Meter Sizes 3/4", 1", 1-1/2" and 2" Features 1" RFM 50 2" RFM 160

Model RFM. Model RFM. Materials and Specifications. Residential Fire Meter Sizes 3/4, 1, 1-1/2 and 2 Features 1 RFM 50 2 RFM 160 Residential Fire Meter Sizes 3/4", 1", 11/2" and 2" Features APPLICATIONS: The Hersey Residential Fire Meter (RFM) is specifically designed for use in residential fire protection systems or combination

More information

Cool Drawer Dual Sensor

Cool Drawer Dual Sensor The Cool Drawer Dual Sensor is designed for use in critical processes where it is desirable to have a second crystal in the vacuum chamber. Water cooled, cast stainless steel sensor body, two Cool Drawer

More information

BLACK & GALVANIZED SCH 40 STEEL NIPPLES

BLACK & GALVANIZED SCH 40 STEEL NIPPLES BLACK & GALVANIZED SCH 40 BLACK AND GALVANIZED Product Specifications Welded steel pipe nipples both galvanized and black in diameters ranging from 1/8 up to 4 in lengths from close to 12 and cut-pipe

More information

Baumann Little Scotty Bronze Control Valve

Baumann Little Scotty Bronze Control Valve 24000 Valve Product Bulletin Baumann 24000 Little Scotty Bronze Control Valve Baumann Little Scotty industrial control valves are intended for general utility service in pressure, flow, and temperature

More information

Water Supply and Sewerage Approved Products Manual - February 2006

Water Supply and Sewerage Approved Products Manual - February 2006 Water Supply and Sewerage Approved Products Manual - February 2006 Water Supply Maintenance Products Section WO 04 Last updated January 2007 CONTENTS SPECIFICATIONS A WO 04-S1A MULTI-PURPOSE UNRESTRAINED

More information

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits

RHM160. Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications. Features. Applications. Benefits RHM160 Coriolis Mass Flow Meter for High Flow Terminal and Pipeline Applications Features Standard Pressure ratings up to 50bar (725 psi) Temperature ratings from -196 to 120 C (-320 to 248 F) Mass flow

More information

GPX 1250 Gas Piston Pump

GPX 1250 Gas Piston Pump GPX 0 Gas Piston Pump Owner s Manual Model Number 0000 SprayTECH 0 Fernbrook Lane Minneapolis, MN Technical Assistance: -00-- Order Entry: -00--00 Fax: -00--0 www.spraytechinc.com Printed in the U. S.

More information

Technical Data Sheet Screw Clamps and Universal Clamps

Technical Data Sheet Screw Clamps and Universal Clamps Technical Data Sheet Screw Clamps and Universal Clamps Stepless Screw Clamps PG 178 2 PG 178 for small diameters PG 178 for big diameters Bridge Tongue-in-groove design Interlock with multiple diameter

More information

Front Load Dual Sensor

Front Load Dual Sensor INFICON Front Load Dual crystal sensors offer proven reliability and durability and have the best thermal stability of any sensor head on the market. The dual sensor provides a backup crystal and is essential

More information

Stainless steel hygienic butterfly valves. F250 for imperial tubing. F251 for metric tubing.

Stainless steel hygienic butterfly valves. F250 for imperial tubing. F251 for metric tubing. Stainless steel hygienic butterfly valves. F for imperial tubing. F for metric tubing. Features Keystone technology. Quarter turn operation. Isolation or regulation control. Equal percentage characteristics.

More information

North US 290 US 183. MLK Blvd. FM 969. ASERO Steel Sales. Ben White TX 71 IH-35 US 183

North US 290 US 183. MLK Blvd. FM 969. ASERO Steel Sales. Ben White TX 71 IH-35 US 183 North US 290 US 8 MLK Blvd. FM 969 ASERO Steel Sales Ben White TX IH- US 8 Hot Rolled Strip Commercial Quality A - 0 Size in Per 20 Ft. /8 x /2.2 4.26 /4.9 6.8.42 8.0 /4. 0.62 /2.68 2.6 2.80.00 2 /2.06

More information

604 SOCKET HEAD BUTTON SCREWS

604 SOCKET HEAD BUTTON SCREWS 600 SOCKET HEAD CAP SCREWS Page........626 634 602 SOCKET SET SCREWS 604 SOCKET HEAD COUNTERSUNK SCREWS 604 SOCKET HEAD BUTTON SCREWS 610 SOCKET HEAD SHOUDER SCREWS Page........635 636 Page........637

More information

G12/G12x USER S MANUAL

G12/G12x USER S MANUAL G12/G12x USER S MANUAL TABLE OF CONTENTS SECTION 1 SLIDE CONFIGURATION SECTION 2 SLIDE CONFIGURATION ACCESSORIES SECTION 3 TABLETOP CONFIGURATION SECTION 4 TABLETOP CONFIGURATION ACCESSORIES SECTION 5

More information

Subsea Valves.

Subsea Valves. Subsea Valves FITOK Group FITOK GmbH (Headquarter) Sprendlinger Landstr., 0 Offenbach am Main, Germany Tel.: + 00 Fax: + 00 FITOK, Inc. North Promenade lvd., Suite 0, Stafford, Texas, US Tel.: + 00 Fax:

More information

Catalogue 2016 HOSE TECHNOLOGY. Fittings, Valves and Accessories. Schauenburg Hose Technology Group

Catalogue 2016 HOSE TECHNOLOGY. Fittings, Valves and Accessories. Schauenburg Hose Technology Group Catalogue 2016 HOSE TECHNOLOGY Fittings, Valves and Accessories Schauenburg Hose Technology Group PREAMBLE The new fittings and accessories range of APD Petzetakis Schlauchtechnik GmbH Quality and reliability

More information

2.4Meter Series 1252 Az/El Truss Mount

2.4Meter Series 1252 Az/El Truss Mount 4096-356 REVISION E April 21, 2016 Assembly Manual 2.4Meter Series 1252 Az/El Truss Mount General Dynamics 1700 Cable Drive NE Conover NC 28613 USA Phone 770-689-2040 www.gdsatcom.com 2.4M Series 1252

More information

Sockets & Accessories

Sockets & Accessories Sockets & Accessories Sidchrome socket sets give you the choice of socket you need to get the job done. Our sets have been designed with flexibility, quality and portability in mind. You can easily carry

More information

SADDLES & SNAP-ON SADDLES

SADDLES & SNAP-ON SADDLES SADDES & SAP-O SADDES When Assembling Spears Saddles to PVC pipe, Spears anufacturing Company recommends Spears PVC-19 Solvent Cement and Spears Primer-68/Primer-70 or equivalent. Although good connections

More information

NEOTECHA. PFA lined Ball Valves - Models SNB and SNC

NEOTECHA. PFA lined Ball Valves - Models SNB and SNC NEOTECHA PFA lined stainless steel ball valve with short face to face and well proven trunnion mounted design for use in pharmaceutical and bio-engineering industries Features PFA lining offers highest

More information

EVOLVE1-M MONITOR ARM

EVOLVE1-M MONITOR ARM EVOLVE1-M MONITOR ARM EVOLVE1-M Rev A 2/17 Model EVOLVE1-M-SLV Model EVOLVE1-M-BLK Model EVOLVE1-M-WHT ASSEMBLY AND ADJUSTMENT EVOLVE1-M MONITOR ARM PARTS AND TOOLS PLEASE REVIEW these instructions before

More information

UNIFLEX TRIPLE SPRING COUPLING

UNIFLEX TRIPLE SPRING COUPLING Specialty Couplings Overview Uniflex Coupling Design Flexible Spring Type Coupling with Exclusive Triple Wound Spring Design The Uniflex Coupling is an all steel, single piece coupling that solves a variety

More information

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio Forward and reversible plate Hatz Electric start 0 mm Hatz Electric start 0 mm Bio Hatz Electric start mm Bio Valid from serial number 0000 0000 0000 Contents Contents General information.....................................................................................................................................

More information

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447

Description: Detailed procedure on removing old bushing and installing new Brake Bushing Replacement Kit 10447 Procedure: BRAKE BUSHING REPLACEMENT PROCEDURE Product: Document #: Rev: Page: MODEL 7000, 7000A, & 8000 GYRO 078 1 1 of 14 Description: Detailed procedure on removing old bushing and installing new Brake

More information

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio

LH 700. Spare parts list. Forward and reversible plate. Valid from serial number. LH 700 Hatz Electric start 810 mm Bio LH 00 Spare parts list Forward and reversible plate LH 00 Hatz Electric start 0 mm LH 00 Hatz Electric start 0 mm Bio LH 00 Hatz Electric start 0 mm LH 00 Hatz Electric start 0 mm Bio Valid from serial

More information

708BS Series Bellows Stem Seal

708BS Series Bellows Stem Seal 708BS Series Bellows Stem Seal Fractional Flow Control Valves FRACTIONAL FLOW CONTROL S CRN Registration Number Available Bellows stem seals eliminate fugitive emissions by surrounding the valve stem with

More information

Compliance with API Standard 670 the PRO Product Standard for Proximity Probes

Compliance with API Standard 670 the PRO Product Standard for Proximity Probes Connection Technology Center, Inc. 7939 Rae Boulevard Victor, New York 14564 Toll Free: (800) 999-5290 Phone: (585) 924-5900 Fax: (585) 924-4680 Compliance with API Standard 670 the PRO Product Standard

More information

VSG, VSL, VSKH and VSKV Two-line Metering Devices

VSG, VSL, VSKH and VSKV Two-line Metering Devices VSG-KR These high quality, galvanized steel metering devices are designed for high-pressure (up to 400 bar) two-line systems. They can also be used in low to medium-pressure systems. They are available

More information

SPIRAL WOUND GASKET. Spiral Wound Gasket CALVOSEALING DESCRIPTION PROPERTIES

SPIRAL WOUND GASKET. Spiral Wound Gasket CALVOSEALING DESCRIPTION PROPERTIES CALVOSEALING Spiral Wound Gasket SPIRAL WOUND GASKET DESCRIPTION Spiral wound gaskets consist of a V-shaped metal strip spirally wound in combination with a soft, filler material. The metal strip provides

More information

SIZES FROM 1, ,000 Nm BACKLASH FREE, TORSIONALLY STIFF METALLIC BELLOWS COUPLINGS

SIZES FROM 1, ,000 Nm BACKLASH FREE, TORSIONALLY STIFF METALLIC BELLOWS COUPLINGS BX ZA SIZES FROM 1,500-100,000 Nm BAKLASH FREE, TORSIONALLY STIFF METALLI BELLOWS OUPLINGS BELLOWS OUPLINGS BX ZA Optional: GENERAL INFORMATION ABOUT R+W BELLOWS OUPLINGS: SERVIE LIFE R+W bellows couplings

More information

MECHANICAL POWER TRANSMISSION. E-Z Kleen and Ultra Kleen Mounted ball bearings

MECHANICAL POWER TRANSMISSION. E-Z Kleen and Ultra Kleen Mounted ball bearings MECHANICAL POWER TRANSMISSION E-Z Kleen and Ultra Kleen Mounted ball bearings 2 E-Z KLEEN AND ULTRA KLEEN BEARINGS Dodge E-Z Kleen and Ultra Kleen Mounted ball bearings Food safety compliance demands equipment

More information

Preparation and Installation of the CM and CMV Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

Preparation and Installation of the CM and CMV Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders Preparation and Installation of the CM and CMV Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders GEP-7011 Rev. F 23777 Ref. ID: 8637 WARNING USER SHOULD READ AND THOROUGHLY

More information

Front Load Single Sensor

Front Load Single Sensor INFICON Front Load Single crystal sensors offer proven reliability and durability and have the best thermal stability of any sensor head on the market. The front load design allows for easy insertion of

More information

CLAMSHELL PIPE CUTTING AND BEVELLING MACHINES. Mactech Europe LTD

CLAMSHELL PIPE CUTTING AND BEVELLING MACHINES. Mactech Europe LTD CLAMSHELL PIPE CUTTING AND BEVELLING MACHINES Mactech Europe LTD Mactech s Clamshell lathes are portable pipe cutting machines designed for on-site precision severing, severing/beveling, and severing/double

More information

Universal Compact Extruded Cylinders

Universal Compact Extruded Cylinders Universal Compact Extruded Cylinders Clippard s new Compact, Extruded Body Cylinders are available in double acting, double rod, single acting spring return, and single acting spring extended models. Universally

More information

Catalogue. electric-, cordless- and. pneumatic power tools. Products for sheet metal processing Edition 2008 / 2009

Catalogue. electric-, cordless- and. pneumatic power tools. Products for sheet metal processing Edition 2008 / 2009 Catalogue electric-, cordless- and pneumatic power tools Products for sheet metal processing Edition 2008 / 2009 Machine Tools / Power Tools Laser Technology / Electronics Medical Technology Slitting shears

More information

MPreC - Pressure Relief Device Order specification sheet

MPreC - Pressure Relief Device Order specification sheet - Pressure Relief Device Order specification sheet -Series LARGE MESSKO PRESSURE RELIEF DEVICE Complete the Order-N o by choosing the specific add-on s: e.g.: LMPRD 685-08-22-N01-00 Order-N o : Parameter

More information

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI

Easy Flow Indicator Magnetisch-Induktiver Durchflussmesser. Type 8024 For Insertion Fittings. Analog Flow Rate Indicator, 1/2-16; P=87 PSI Analog Flow Rate Indicator, 1/2"-16"; P=87 PSI Advantages / Benefits Reduced costs of ownership up to 6% Economic integration in pipe systems without any additional piping Shows flow rate with a clear,

More information

Specification. Radiamatic Detectors and Accessories

Specification. Radiamatic Detectors and Accessories 4/92 Page 1 of 8 Radiamatic Detectors and Accessories Specification Function The Radiamatic temperature detector generates an emf proportional to the temperature of the object sighted. It is used with

More information

Daniel SeniorSonic 3414 Four-Path Gas Ultrasonic Flow Meter. Datasheet August 2014

Daniel SeniorSonic 3414 Four-Path Gas Ultrasonic Flow Meter. Datasheet August 2014 Daniel SeniorSonic 3414 Four-Path Gas Ultrasonic Flow Meter Datasheet August 2014 Gas Ultrasonic Flow Meter Datasheet SeniorSonic 3414 Gas Ultrasonic Flow Meter Intelligent Measurement Technology Engineered

More information