Nexans Cabling Solutions COPPER PRODUCT GUIDE

Size: px
Start display at page:

Download "Nexans Cabling Solutions COPPER PRODUCT GUIDE"

Transcription

1 Nexans Cabling Solutions COPPER PRODUCT GUIDE i

2 NEXANS BRINGS ENERGY TO LIFE Nexans brings energy to life through an extensive range of cables and cabling solutions that deliver increased performance for our customers worldwide. Nexans teams are committed to a partnership approach that supports customers in four main business areas: Power Transmission and Distribution (Submarine and Land), Energy Resources (Oil & Gas, Mining and Renewables), Transportation (Road, Rail, Air, Sea) and Building (Commercial, Residential and Data Centers). Nexans strategy is founded on continuous innovation in products, solutions and services, employee development, customer training and the introduction of safe, low environmental impact industrial processes. In 2013, Nexans became the first cable player to create a Foundation to introduce sustained initiatives for access to energy for disadvantaged communities worldwide. We have an industrial presence in 40 countries and commercial activities worldwide, employing close to 26,000 people and generating annual sales of more than 6.4 billion euros. Nexans is listed on NYSE Euronext Paris, compartment A. In the field of LAN Cabling Systems, Nexans Cabling Solutions offer a complete range of products and value-added services providing improved reliability and reduced cost of ownership for Network Managers, together with faster installation times for installers. Nexans offers an unrivaled choice of LAN infrastructure solutions to a global customer base through an extensive network of regional offices and a Key Account Management team. Nexans Cabling Solutions. All rights reserved. LANmark is a registered trademark of Nexans. Release date: August Nexans Cabling Solutions 140 Allstate Pkwy, Markham, ON L3R 0Z7, Canada Tel: Nexans TEK Center 132 White Oak Rd, New Holland, PA Tel: Fax: ncs.canada@nexans.com

3 TABLE OF CONTENTS SMART CHOICES TO MAXIMIZE INVESTMENT Total Cost of Ownership...2 Applications...4 Comprehensive Copper Solutions...6 Categories and Performance Permanent Link Testing vs. Channel Testing...8 Configurations...8 Converged Application Score...10 Warranty...11 LANMARK COPPER SOLUTIONS Copper Solutions Overview...12 LANmark-6A FTP System...14 LANmark-6 Series System...16 LANmark-6E System...16 LANmark-6+ System...17 LANmark-6 System...18 LANmark-5 System...20 LANmark-IP: Specially Designed for High PoE...23 Modular Patch Panels...24 LANmark Faceplates...26 Cable Management...28 Tools and Accessories...30 Zone Distribution Boxes...31 ESSENTIAL COPPER SOLUTIONS Essential-6 System...32 Essential-5 System...32 Essential Work Area Faceplates...34

4 TOTAL COST OF OWNERSHIP Enabling Sustainability Higher grade cabling Design flexibility Product Environmental Profile (PEP) Health Product Clarification (HPD) Anticipating Technology Change Convergence Virtualization Power over Ethernet (PoE) Meeting Higher Bandwidth Needs 10G in office 25G and 40G in data center Migration paths Improving Network Reliability Quality products Converged Application (CA) score Enhanced performance The physical cabling infrastructure plays a critical role in key networking issues which have an impact on business performance. Investing in the right solution and partner is not only an issue to consider during installation, but the consequences will have a significant impact on the end user s cost of ownership. It is vital to plan for a cabling system that can support several generations of active equipment. Bandwidth Demand Planning a Smart Migration Path By 2021, the gigabyte equivalent of all movies ever made will cross The Internet every minute. - Cisco The global rate of growth of data is almost beyond comprehension. In 2010, 1,000 Exabytes of data (equivalent to around 250 billion DVDs) was produced; 75 percent by individuals and 25 percent by machines. The data produced by devices is set to increase due to the Internet of Things (IoT), as more and more devices will be connected to the Internet. In total, around 35 Zettabytes of data will be produced by Reliability Enhanced Performance for Converged Applications The ability to control change is without doubt the major contributor to business value. - British Computer Society (BCS) Network reliability issues and system performance issues can result in lengthy downtime and damage both business operations and reputation. Reliability can be improved by adopting high-quality products that are designed to create a system that can handle the demands of today s information intensive businesses. 2

5 Lifetime of a Good Cabling System Cabling >15 years Active Equipment 5 years Product Lifespan Workstation 3 years Network Investment Software 1.5 years Not Just Data Also Power! Power over Ethernet, especially next generation High Power PoE, is a key driver for the adoption of IP convergence, reducing the need for separate power cabling, saving installation costs and limiting administration overhead. Remote powering of devices will increase the temperature in cabling bundles. High performance shielded cabling and cables with metallic crosstalk barriers will allow larger bundle sizes, while keeping temperatures within the listed rating. Studies have been made on the heating effect power delivery has on cables; however component standards for connectors do not include PoE+ compliance which means customers need to ensure that they specify PoE-ready-connectors. Additionally, there is a clear trend towards powering devices which draw up to 100W, which means minimum PoE+ compliance (i.e. Cat 5e) is not good enough. The support of higher power delivery requires good cabling design and higher grade of cabling, including PoE-ready-connectors. Technology Change Anticipating & Managing IT Evolution Significant innovation continues in the field of IT driven by volume, velocity and variety of information. - IDC Network cabling, whether in the office or data center, has to be flexible to support changing technology trends: Virtualization Cloud Top of rack or end of row Convergence Data center Ethernet Sustainability Cabling Selection Will Impact Energy Consumption By 2020 IT will be more polluting than aviation. - The Economist Increased demand for power caused by accelerating IT growth creates direct conflict for IT managers as environmental regulation intensifies and energy costs increase. The need to plan data center infrastructure to ensure that it is best equipped to maximize efficiency and reduce total cost of ownership has never been greater. The choice of cabling will impact cost of ownership. 3

6 APPLICATIONS LAN/Enterprise Today s LAN/Enterprise network manager must ensure that the network cabling system is prepared for the constant evolution of technology and user requirements. Nexans provides a complete family of copper and fiber cables, connectors and pre-terminated solutions. These products are suitable for a wide range of premise environments, from campus backbone infrastructure, through building entrance facilities, to the desktop. Data Center/SAN Mission critical data centers and SANs require reliable, flexible and scalable fiber optic and copper cabling. Nexans offers the smallest diameter and highest bandwidth optical fiber cables, addressing important, current issues such as reliability and cooling. Education Nexans offer a wide suite of cabling products for educational institutions which take advantage of new converging technologies such as distance learning, distributed computing, interactive teaching tools and IP telephony. From small schools to large university campuses, Nexans cabling provides high-speed data and voice connections in classrooms, offices, laboratories and student accommodation. 4

7 Finance Financial institutions require 24/7 real-time networks that are fast, reliable and secure to keep the economy moving. From local banking to global online trading, financial transactions depend on constant connections. Detailed private records need to be accessible and secure. A high-speed, diverse cabling system that is scalable for this fast paced environment is worth its weight in gold. Healthcare The global sharing of research and remote diagnostic techniques provide life-saving patient care. This can only be achieved through a high speed, dependable cabling system. From accessing patient records to transmitting extremely large graphic files, such as MRI scans and other highresolution imaging, today s medical activities rely on their cable network. Nexans cabling has become a critical component in every healthcare application. As today s hospitals migrate to a paperless environment, file transfer and storage considerations have become a key factor in cabling selection. Retail Retail communication requirements are increasing. Efficiency improvements to track sales and speed up PoS transactions require high-quality LAN cabling. Nexans can help you identify the right type of infrastructure to meet the different needs of your headquarters, data center, warehouse and stores. High performance and low maintenance costs are ensured. Our LANmark cabling solutions offer the flexibility to make changes and deploy new technologies such as converged IP networks, including security cameras. 5

8 COMPREHENSIVE COPPER SOLUTIONS LANmark-5 Solutions For temporary space, a short term lease, or small office applications a Category 5e system may meet your needs. Capable of supporting Fast and Gigabit Ethernet speeds the LANmark-5 Solution provides robust, reliable Category 5e channel performance to support the most common commercial office applications as well as security applications such as video surveillance, access control, and occupancy sensors. A LANmark-5 solution is also ideal for IoT deployments for many kinds of sensors and intelligent systems. And Nexans will soon be introducing an enhanced PoE Cat 5e cable that delivers power more efficiently than any other category cable on the market. LANmark-6 Series Solutions Nexans LANmark-6 series solutions are available in three distinct performance levels. LANmark-6, LANmark-6+, and LANmark-6E. Each solution offers a level of performance designed to provide optimal support for increasingly higher bandwidth applications. The LANmark-6 Solution is the most fundamental cabling solution for most commercial office deployments. The LANmark-6+ solution provides headroom over Cat 6 channel requirements and is ideal for the support of emerging 2.5 Gbps applications in addition to Gigabit Ethernet. And finally the LANmark-6E solution is the highest performing Cat 6 channel available and is suited to support 1Gbps and emerging 5 Gbps Ethernet speeds. LANmark-6A Solutions 6 A Category 6A solution from Nexans is the right choice for long term installations designed to support everything from standard office networks to data center switch to server connections. The LANmark-6A FTP solution provides the highest Category 6A performance available to support 10 Gbps Ethernet connections where you need them most; in your data center and connecting your high-speed, high-bandwidth wireless access points. A LANmark-6A solution is the recommended system for Healthcare environments where cabling upgrades are difficult and costly.

9 CATEGORIES AND PERFORMANCE Horizontal Cabling a) A Performance Level for Every Application By horizontal cabling, we mean the cabling which connects the floor distributor to the outlets at the workplace. This is usually done with a 4-pair copper cable. Nexans offer a full range of copper solutions which exceed the requirements of standard categories. Solution Category Cable Type Bandwidth Application LANmark-5 5e LANmark-5e UTP 100 MHz Gigabit Ethernet LANmark-6 6 LANmark-6 UTP 250 MHz Gigabit Ethernet LANmark-6+ 6 LANmark-1000 UTP 250 MHz 2.5 Gbps Ethernet LANmark-6E 6 LANmark-2000 UTP 250 MHz 5.0 Gbps Ethernet LANmark-6A 6A LANmark-6A FTP 500 MHz 10 Gigabit Ethernet b) Guarantees of Distances Covered The standards (ISO/IEC, EN and EIA/TIA) are based around a maximum channel length of 100m. In the event of a request for a specific application guarantee, Nexans provides cover for the longest channels according to the type of application. This provision only applies when Nexans products are used exclusively along the channel in question. Application LANmark Drive Distance (m) 5e 6 6A 10BASE-T (Ethernet) BASE-TX (Fast Ethernet) BASE-T (Gigabit Ethernet) GBASE-T (10 Gigabit Ethernet) n/a n/a 100 Token Ring (16 Mbps) IBM RS232 1,200 1,200 1,200 AS400/System 3X ISDN Basic Rate

10 PERMANENT LINK TESTING VS. CHANNEL TESTING Active Equipment Permanent link Channel PC In the TIA standards two different ways of testing are described. A permanent link is the fixed part of the cabling, which is normally tested after installation. These test results give information on installation quality. The permanent link extends from the patch panel in the cabinet to the telecommunications outlet at the user side. It excludes work area cords, equipment cords and cross-connections, but does include the optional consolidation point. A channel represents the complete end-to-end path between the user equipment (PC, phone, video, printer, etc.) and the active equipment at the cabinet side (switch, hub, PBX, video equipment). The channel includes the work area cord, the equipment cord and the cross-connection. CONFIGURATIONS 2 Connector Channel/Interconnect Telecom Outlet (TO) model 2 Connector Channel 2 connector channel In an implementation of generic cabling, one assembly of TOs directly linked back to the Floor Distributor (also known as a Distributor room) serves a single work area. Floor Distributor (FD) Patch panel Horizontal cable Outlet Equipment cord Work area cord Switch Computer 8

11 3 Connector Channel with Consolidation Point (CP)/Interconnect CP TO Model 3 Connector Channel With CP In an open office environment the work areas regularly need to be reconfigured. As a consequence the installation of a Consolidation Point between the FD and the outlet (TO) can be useful in order to provide flexibility of reallocating the TOs. The CP (Zone Distribution box) is located in the space above the ceiling or under the raised floor. Floor Distributor (FD) Patch panel Equipment cord Horizontal cable Consolidation Point (Zone Distribution box) Plug / Jack CP cord Work area cord Outlet Switch Computer 3 Connector Channel With Presentation Panel/Crossconnect TO Mode 3 Connector Channel With Cross-Connect Presentation panels (also called representation panels or mirror panels) are used where horizontal distribution patch panels are located away from active equipment. They can also be used to protect switch ports from wear and tear. All switch ports are permanently connected to a presentation panel and the connection with the horizontal panel is performed between the presentation and the horizontal panel to create a cross-connect area. 4 Connector Channel With CP and Presentation Panel/Cross-Connect CP - TO Model 4 Connector Channel With Cross-Connect & CP This last configuration includes both CP and presentation panel. It is the worst case scenario regarding data transmission performance as there are four RJ45 jack/ plug connections in the link. All LANmark systems are warranted to exceed the standard electrical parameters when using the worst case 4 connector channel scenario. 9

12 CONVERGED APPLICATION SCORE x.x Converged Application Score To accommodate bandwidth expansion you need cabling that offers the ideal balance between delivering data AND power. This requires a new way of testing and evaluating cabling performance. Nexans Converged Applications (CA) score defines how the cabling network s performance will affect the user s experience. Using realistic test scenarios, it measures how network infrastructure will perform against future demand and converging applications. The CA score is an indicator of IP traffic protection as it is related to cabling system performance. Unlike traditional methods that measure a channel s frequency response in decibels (dbs) and reports a pass/fail result, Nexans conducts much more rigorous testing with real world applications and the results show how well the equipment and business systems that are running on the cabling system will function or not. The testing is conducted on a channel that is exposed to electrical fast transient (EFT) voltage spikes from adjacent power cabling with 75m exposed to increased temperatures while IP video, VoIP traffic, and high Power over Ethernet are transmitted simultaneously. Empirical testing on these channels includes: Mean Opinion Score (MOS) A quality of service metric used to measure VoIP Frame Error Rate (FER) A measurement of the integrity of IP data transmission Media Loss Rate (MLR) A quality of service metric used mainly to measure IP video Heat Rise from PoE A measurement of how efficiently the cabling dissipates heat Nexans feeds these test results into an algorithm that incorporates total channel bandwidth as well as Signal to Noise Ratio values and reach capability for 1, 2.5, 5, and 10 Gbps Ethernet. The output is the Converged Application score for each channel tested in a range between 1 and 20. The better IP traffic is protected from the stress of multiple simultaneous applications, noise, and heat, the higher the score. In short, the Nexans CA score is an indicator of the user experience based on real world applications and environmental conditions. Converged Application (CA) Score Results for LANmark Channels LANmark-6 (CAT 6) 7.8 LANmark-1000 (CAT 6) 8.2 LANmark-2000 (CAT 6) 9.0 LANmark-6A (CAT 6A) 19.3 POOR GOOD BETTER BEST

13 WARRANTY Link Warranty Online Self-Certification Nexans provide a unique 25 year self-certification link warranty for standard Cat 5e and Cat 6A installations which is available for all installers. Instant no waiting while application is processed Customized certificate includes details of end customer and installer Easy simply complete the short online form, generate and print the PDF certificate Certified Solution Warranty Complete Confidence Nexans Certified Solution Warranty is the most comprehensive guarantee on the market covering: Copper and fiber Channel performance above the standards - horizontal, campus and backbone Application support Labor* *Nexans funds the removal and reinstallation of proven defective products when system is installed by a fully certified solution provider. What is included Link Warranty Certificate Certified Solution Warranty Brands covered: LANmark Essential Copper categories covered: Cat 5e Cat 6 Cat 6A p p p p p p - p p p Fiber - p Parts p p Link performance p p Full end-to-end channel - p* Application guarantee - p* Extended distance support - p* Replacement labor - p** Nexans checked & validated - p Validity 25 years 25 years *with Nexans patch cords **when installed by Certified Solutions Partner 11

14 LANMARK COPPER SOLUTIONS to office building Modular Patch Panels Compatible with all Snap-In connectors 24 ports Sliding and fixed versions available Clip-on cable management Exclusive auto-connect earthing system Angled Panels Optimal construction for data center cabling Ideal for high density patching Angled pass-through and blank panels available Overhead Patching Frame 4U open frame For overhead vertical or angled installation Mounts under or over cable trays Patch cord management accessories 12

15 to data center LANMARK COPPER SOLUTIONS TABLE OF CONTENTS LANmark Systems...14 Patch Panels...24 Copper Cables Cat 5e through Cat 6A Standard and enhanced performance options High power PoE approved Faceplates...26 Cable Management...28 LANmark UniBoot Patch Cords Cat 5e, 6, 6A Removable latch protector available in Dark Grey LANmark Snap-In Connector High performance for every application Supports data applications up to 500 MHz Cat 6A Tools & Accessories...30 Zone Distribution Boxes

16 LANMARK-6A FTP SYSTEM The Nexans LANmark-6A FTP cabling system is the ideal solution for enterprise and data center environments, offering guaranteed bandwidth to 500 MHz and supporting 10GBASE-T, the highest performing application available today over horizontal copper cabling LANmark-6A FTP cables and connectivity are manufactured and tested to the latest Cat 6A specifications defined in the International, European and American cable and cabling standards, including ISO 11801, EN and TIA-568-C.2. The LANmark-6A FTP range supports up to three connection points within a 10m link or a 12m channel. This makes it an ideal solution for modern data centers that are already facing severe space problems and where overlength cable is often installed in order to comply with a traditional minimum channel length of 24m. By reducing this minimum length, data centers no longer need to install unnecessary excess cable, therefore reducing costs while also saving critical space. Proper cable shielding eliminates interference from adjacent cables and other noise sources. Shielded cables also dissipate heat from high power PoE much more efficiently than UTP cables, which allows larger bundles in cable channels. This contributes to lower installation costs. Shielded systems provide significant headroom to ANEXT, as well as a high degree of overall noise immunity. Guaranteed superior channel headroom for : NEXT (4dB) Return loss (4dB) Alien crosstalk (6.5dB) (no expensive ANEXT testing required) No * passes Ability to install very short links LANmark-6A FTP Cable Ideal cable for 10GBASE-T applications Full compliance to latest standards for Cat 6A and Class EA Guaranteed performance up to 500MHz Outstanding signal isolation Superior alien crosstalk performance ROHS compliant Part Number N181.6AP40R N181.6AP20R N181.6AP93R N181.6AR40R N181.6AR20R N181.6AR93R Description LANmark-6A FTP CMP, Blue, Reel, 1,000ft LANmark-6A FTP CMP, White, Reel, 1,000ft LANmark-6A FTP CMP, Dark Grey, Reel, 1,000ft LANmark-6A FTP CMR, Blue, Reel, 1,000ft LANmark-6A FTP CMR, White, Reel, 1,000ft LANmark-6A FTP CMR, Dark Grey, Reel, 1,000ft 14

17 LANmark-6A Snap-In Connector High bandwidth RJ45 connector supporting 10G Ethernet Fully compliant with TIA and ISO Cat 6A channel and connector standards Supports very short Cat 6A channel configurations, often required in data centers 360 shielding offering full ANEXT elimination Fast and easy termination without punch down tool Wire organizer reduces risk of installation errors and ensures consistent performance Reterminable Version for stranded wire available for CP to TO links Supports PoE Plus applications (up to 100W) An adapter can be added to fit the keystone format Certified by Delta independent test lab Part Number N420.66A N420.67A N420.66A BULK100 N420.66A ECO24 Description LANmark-6A Snap-In Connector for Solid Conductor Cable LANmark-6A Snap-In Connector for Stranded Conductor Cable LANmark-6A Snap-In Connector for Solid Conductor Pack LANmark-6A Snap-In Connector for Solid Conductor - 24 Pack LANmark-6A Ultim UniBoot Patch Cords High speed RJ45 patch cord to run 10GBASE-T and future Cat 6A applications High density support due to slim boot design Frequency range up to 500 MHz, fully compliant with Cat 6A TIA-568-C.2 and ISO11801:2011 Fully shielded offering internal and external noise (NEXT and ANEXT) protection Black removable latch protector, replaceable with 7 other colors, offering possibility of differentiation between services Part Number Description Patch Cord Length* N11A.P9F010DK LANmark-6A Patch Cord, Cat 6A, FTP, UL, CM 1.0m N11A.P9F020DK LANmark-6A Patch Cord, Cat 6A, FTP, UL, CM 2.0m N11A.P9F0B0DK LANmark-6A Patch Cord, Cat 6A, FTP, UL, CM 3.0m N11A.P9F050DK LANmark-6A Patch Cord, Cat 6A, FTP, UL, CM 5.0m N11A.P9F100DK LANmark-6A Patch Cord, Cat 6A, FTP, UL, CM 10.0m *other lengths available. Contact us for more information. See page 22 for colored latch protectors. 15

18 LANMARK-6 SERIES SYSTEMS The Nexans LANmark-6 series of cabling solutions offers a range of Category 6 performance grades specifically designed to support both legacy and emerging applications across a wide variety of ICT network environments. Whether you are supporting a small business, several floors of leased space in an office tower, or an entire campus, the LANmark-6 Series of solutions has what you need to maintain flawless application performance and guarantee the network lifespan you expect. LANmark-6E Series System The Nexans LANmark-6E system is comprised of our high performance 9.0 LANmark-2000 cable together with the LANmark-6 Snap-In connector and LANmark-6 UniBoot patch cords. This system exhibits the highest level of Category 6 performance available well beyond Category 6 channel requirements and is ideal for supporting higher power PoE (60W and 100W) and extreme bandwidth applications such as 5.0 Gbps Ethernet. The LANmark-6E system is specifically designed to handle the stresses of simultaneous Voice, Data, Video and Power transmission in less than ideal installation environments. CA score of 9.0 provides best in class user experience Ideal for 5 Gbps Ethernet as well as 2.5 Gbps, 1 Gbps, and Fast Ethernet Matched components ensuring minimized signal loss and maximum throughput Significantly exceeds Category 6 channel performance requirements 25 year full system warranty* LANmark-2000 Cable Provides additional performance margin to reliably support high speed networks in high-noise environments Increased bandwidth provided for multimedia, broadband video, analog video and other future applications Guarantees Gigabit Ethernet channel support beyond 100m Characterized to 600 MHz, 350 MHz greater than the standard 90 C listing allows for bundle sizes up to 480 cables supporting 100W PoE 25 year full system warranty* Part Number N180.62P93X N180.62P20X N180.62P40X N180.62R93X N180.62R20X N180.62R40X Description LANmark-2000 CMP, Dark Grey, Reel, Box LANmark-2000 CMP, White, Reel, Box LANmark-2000 CMP, Blue, Reel, Box LANmark-2000 CMR, Dark Grey, Reel, Box LANmark-2000 CMR, White, Reel, Box LANmark-2000 CMR, Blue, Reel, Box *when installed by Certified Solutions Partner See page 19 for connector and patch cord information. 16

19 LANmark-6+ System The Nexans LANmark-6+ system featuring LANmark-1000 cable, 8.2 LANmark-6 Snap-In connectors and LANmark-6 Patch Cords offers significant Category 6 channel performance headroom and is ideal for supporting higher speed applications such as 2.5 Gbps Ethernet in addition to Gigabit and Fast Ethernet. The enhanced performance of LANmark-1000 cables also provides for increased bundle sizes when supporting High PoE power levels, including 60W and 100W. The LANmark-6+ system is perfectly suited to today s commercial office, healthcare center, and educational campuses where several applications may be sharing the network bandwidth simultaneously. Increased bandwidth ideal for 2.5 Gbps Ethernet as well as Gigabit and Fast Ethernet CA score of 8.2 ensures outstanding application performance Exceeds Category 6 channel performance requirements 25 year full system warranty* LANmark-1000 Cable Provides additional bandwidth required for multiple simultaneous applications Addition of balance requirements improves overall cable performance and reduces cable emissions which results in reduced transmission errors Characterized to 550 MHz, 300 MHz greater than the standard 75 C listing allows for bundle sizes up to 312 cables supporting 100W PoE Part Number N180.61P93B N180.61P70B N180.61P20B N180.61P40B N180.61R93B N180.61R70B N180.61R20B N180.61R40B Description LANmark-1000 CMP, Dark Grey, Box LANmark-1000 CMP, Yellow, Box LANmark-1000 CMP, White, Box LANmark-1000 CMP, Blue, Box LANmark-1000 CMR, Dark Grey, Box LANmark-1000 CMR, Blue, Box LANmark-1000 CMP, White, Box LANmark-1000 CMR, Yellow, Box *when installed by Certified Solutions Partner See page 19 for connector and patch information. See page 24 for patch panel information. 17

20 LANmark-6 System The Nexans LANmark-6 System is the ideal system for covering the basics of today s small office or commercial spaces with a relatively short term 7.8 lease. The LANmark-6 system includes LANmark-6 cable and connectivity that are manufactured and tested to industry standard Category 6 specifications with each component fully compliant to the TIA-568-C.2 requirements. LANmark-6 components are designed to meet or exceed the quality and performance criteria needed to support applications up to 250 MHz, including 1000BASE-T Gigabit Ethernet. Ideal solution for most common enterprise applications operating over Fast Ethernet or Gigabit Ethernet networks Matched components ensuring minimized signal loss and maximum throughput Meets standard channel performance requirements with margin for application performance reliability 25 year full system warranty* LANmark-6 Cable Small, flexible, no-filler design is easy to install Meets the requirements of ANSI/TIA/EIA-568-C.2 Characterized to 500 MHz, 250 MHz greater than the standard Available in cost saving 1,500ft smartpaks RoHS compliant Part Number N180.60P93B N180.60P93S N180.60P20B N180.60P20S N180.60P70B N180.60P70S N180.60P40B N180.60P40S N180.60R93B N180.60R93S N180.60R20B N180.60R20S N180.60R40B N180.60R40S N180.60R70B N180.60R70S *when installed by Certified Solutions Partner Description LANmark-6 CMP UTP, Dark Grey, Box LANmark-6 CMP UTP, Dark Grey, 1,500ft, smartpak LANmark-6 CMP UTP, White, Box LANmark-6 CMP UTP, White, 1,500ft, smartpak LANmark-6 CMP UTP, Yellow, Box LANmark-6 CMP UTP, Yellow, 1,500ft, smartpak LANmark-6 CMP UTP, Blue, Box LANmark-6 CMP UTP, Blue, 1,500ft, smartpak LANmark-6 CMR UTP, Dark Grey, Box LANmark-6 CMR UTP, Dark Grey, 1,500ft, smartpak LANmark-6 CMR UTP, White, Box LANmark-6 CMR UTP, White, 1,500ft, smartpak LANmark-6 CMR UTP, Blue, Box LANmark-6 CMR UTP, Blue, 1,500ft, smartpak LANmark-6 CMR UTP, Yellow, Box LANmark-6 CMR UTP, Yellow, 1,500ft, smartpak See page 19 for connector and patch information. See page 24 for patch panel information. 18

21 LANmark-6 Series Connectors and Patch Cords LANmark-6 Snap-In Connector Supports three Cat 6 channel performance levels Wire organizer reduces risk of installation errors Wiring according to color code T568B or T568A Reterminable Version for stranded wire available for CP to TO links Supports PoE+ applications up to 100W An adapter can be added to fit the keystone format Quick, easy tool-less termination Part Number Description N LANmark-6 Snap-In Connector, Dark Grey N BLU N GRE N ORA N RED N ECO24 LANmark-6 Snap-In Connector, Blue* LANmark-6 Snap-In Connector, Green* LANmark-6 Snap-In Connector, Orange* LANmark-6 Snap-In Connector, Red* LANmark-6 Snap-In Connector, Dark Grey, 24-pack N LANmark-6 Snap-In Connector, Dark Grey, for stranded wire *Made to Order - call for minimum order quantity and availability LANmark-6 UniBoot Patch Cords Supports three Cat 6 channel performance levels Complies with Cat 6 cabling and component standards Fully matched with LANmark-6, LANmark-1000, and LANmark-2000 cables and LANmark-6 connector ensuring maximum channel performance C(UL)US listed Black removable latch protector, replaceable with 7 other colors, for easy application identification Part Number Description Length N116.P9A010DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 1.0m N116.P9A015DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 1.5m N116.P9A020DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 2.0m N116.P9A025DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 2.5m N116.P9A030DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 3.0m N116.P9A040DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 4.0m N116.P9A050DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 5.0m N116.P9A060DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 6.0m N116.P9A070DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 7.0m N116.P9A080DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 8.0m N116.P9A090DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 9.0m N116.P9A100DK LANmark UTP Cat 6 Patch Cord, Black Latch protector, CM rated, Dark Grey 10.0m See page 22 for colored latch protectors. 19

22 LANMARK-5 SYSTEM For temporary space, a short-term lease, or small office applications a Category 5e system may meet your needs. Capable of supporting Fast and Gigabit Ethernet speeds the LANmark-5 Solution provides robust, reliable Category 5e channel performance to support the most common commercial office applications as well as security applications such as video surveillance, access control, and occupancy sensors. A LANmark-5 solution is also ideal for IoT deployments for many kinds of sensors and intelligent systems. LANmark-5e Cable Small, round design ETL Verified to ANSI/TIA-568-C.2 and ISO/IEC Reliably supports 100BASE-TX and 1000BASE-T Ethernet Reduced installation costs and maintenance Lower bit error rates, increases network efficiency and uptime Characterized to 450 MHz, 350 MHz greater than standard Part Number N180.53P93B N180.53P40B N180.53P20B N180.53R93B N180.53R40B N180.53R20B Description LANmark-5e CMP UTP cable, Dark Grey, Box, 1,000ft LANmark-5e CMP UTP cable, Blue, Box, 1,000ft LANmark-5e CMP UTP cable, White, Box, 1,000ft LANmark-5e CMR UTP cable, Dark Grey, Box, 1,000ft LANmark-5e CMR UTP cable, Blue, Box, 1,000ft LANmark-5e CMR UTP cable, White, Box, 1,000ft LANmark-5 Snap-In Connector Designed to reach the highest performance in Cat 5e Outstanding performance for attenuation (insertion loss), NEXT/FEXT, Power Sum NEXT/FEXT and Return Loss Exceeds the Cat 5e connector specs in ISO/IEC 11801:2002 and TIA-568-C.2 Exceeds the link and stringent four-connector channel requirements as defined in the ISO/IEC 11801:2002 standard and TIA D Part Number Description N LANmark-5 Unscreened Snap-In connector, White N LANmark-5 Unscreened Snap-In connector for stranded wire, White 20

23 LANmark-5e UniBoot Patch Cords Small cross section allows neat installation and simplifies the creation of bundles in cabinets 1, 2, 3, 5, 10 and 20m are standard lengths available from stock; other lengths are available on demand Rugged construction High connector retention force due to molded connectors External strain relief Self-latching, high reliability RJ45 (ISO 8877) connectors Part Number N115.P9A010DU N115.P9A015DU N115.P9A020DU N115.P9A025DU N115.P9A030DU N115.P9A040DU N115.P9A050DU N115.P9A060DU N115.P9A070DU N115.P9A080DU N115.P9A090DU N115.P9A100DU Description LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey LANmark UTP Cat 5e Patch Cord, without Latch protector, CM rated, Dark Grey Patch Cord Length 1.0m 1.5m 2.0m 2.5m 3.0m 4.0m 5.0m 6.0m 7.0m 8.0m 9.0m 10.0m 21

24 Colored Latch Protectors for LANmark UniBoot Patch Cords Retrofit colored latch protectors Fits all LANmark UniBoot patch cords For differentiation between services Available in 8 different colors Packed in bags of 50 Part Number N110.LPK N110.LPB N110.LPD N110.LPG N110.LPO N110.LPR N110.LPW N110.LPY Description LANmark UniBoot Patch Cord Latch Protector, Black, 50x LANmark UniBoot Patch Cord Latch Protector, Blue, 50x LANmark UniBoot Patch Cord Latch Protector, Dark Grey, 50x LANmark UniBoot Patch Cord Latch Protector, Green, 50x LANmark UniBoot Patch Cord Latch Protector, Orange, 50x LANmark UniBoot Patch Cord Latch Protector, Red, 50x LANmark UniBoot Patch Cord Latch Protector, White, 50x LANmark UniBoot Patch Cord Latch Protector, Yellow, 50x 22

25 LANMARK-IP: SPECIALLY DESIGNED FOR HIGH POE AVAILABLE EARLY 2018 LANmark-IP is the ideal solution for high-power, low bandwidth applications such as PoE-powered IP lighting. Unlike high-bandwidth applications such as wireless access points and HD video, which require a 10 Gbps connection to operate at top performance, IP lighting operates very effectively over a 1 Gbps network. However, typical 1 Gbps cabling can t efficiently overcome the main challenge associated with PoE high power (60W and 100W) and the heat rise that comes with it. Excessive heat rise can interfere with IP traffic, resulting in transmission errors and an underperforming network. LANmark-IP more effectively manages the heat generated by high-power PoE because it is specially constructed with 22AWG conductors and all-fep insulation. In TEK Center testing, LANmark-IP generated 44% less heat rise than traditional Category 5e cabling (based on 192-cable bundles with all cables energized to 100W). Less heat rise means less cooling will be required, which can contribute to energy cost savings. Additionally, LANmark-IP has a temperature rating of 90 C, making it suitable for even the hottest plenum spaces. LANmark-IP is also more energy efficient than traditional Category 5e and Category 6 cables. LANmark-IP is 88% efficient, which means that 88% of the power transmitted by the Power Sourcing Equipment (PSE) will reach the powered device (PD). Category 5e and standard Category 6 cables range from 55-68% efficiency, depending on conductor size. LANmark-IP Ideal for high PoE, low bandwidth applications 22 AWG, all FEP insulated conductors 90 C temperature listing Small OD size of 0.24in No center filler Guaranteed performance up to 250 MHz 44% cooler under 4PPoe vs. traditional Category 5e or 6 88% power efficiency for reduced energy costs 23

26 MODULAR PATCH PANELS Part Number: N BK Patch Panel 24 Port, Snap-In, Fixed, Black, 1U Compatible with all LANmark Snap-In connectors 24 Snap-In ports with shutters Clip-on cable management mechanism Exclusive Auto-Connect earthing system Universal design supporting unscreened and screened connectors Also available in White P/N N Part Number: N BK Patch Panel 24 Port, Snap-In, Sliding, Black, 1U Sliding mechanism for front of rack access Compatible with all Snap-In connectors 24 Snap-In ports with shutters Clip-on cable management mechanism Exclusive Auto-Connect earthing system Universal design supporting unscreened and screened connectors Fully painted design Also available in White P/N N

27 Patch Panel 24 Port, Snap-In, Fixed, Black, 1U Part Number: N BK Compatible with all LANmark Snap-In connectors 24 Snap-In ports with shutters Exclusive Auto-Connect earthing system Universal design supporting unscreened and screened connectors Tie wrap features for cable strain relief Angled Patch Panel 24 Port, Snap-In, Black, 1U Part Number: N Supports high density patching - ideal for data centers Eliminates the need for patch cable management Compatible with all Snap-In connectors Exclusive Auto-Connect earthing system Universal design supporting unscreened and screened connectors Also available in White P/N N

28 LANMARK FACEPLATES Part Number: N Single Gang Cover Plate for 45x45 Outlet Module Accepts 45x45mm flat or angled modules for up to 2 Snap-In connectors Suitable for fiber and copper Includes integrated labelling system Supplied with screws, icons All plastic material is UL 94V0 Color: White (RAL 9010) Part Number: N LANmark Flat 45x45 Module 2 Port, Snap-In Takes up to 2 LANmark Snap-In connectors Equipped with shutters Additional label area All plastic material is UL 94V0 Additional shutter colors available in bags of 10 Fits N cover plate Color: White (RAL 9010) Part Number: N , 1-Port N N, 2-Port LANmark Angled 45x45 Module 1- and 2-Port, Snap-In Accepts 1 or 2 LANmark Snap-In connectors Equipped with shutters Additional label area All plastic material is UL 94V0 Additional shutter colors available in bags of 10 Color: White (RAL 9010) 26

29 Single Gang 60x45 Cover Plate for 45x20 Outlet Modules Part Number: N Holds up to two 45x20mm Connector Modules and one 45x20mm Blanking Module Two 45x20mm Connector Modules to hold up to 4 LANmark Snap-In connectors Suitable for fiber and copper Includes integrated labelling system Supplied with screws, icons All plastic material is UL 94V0 Color: White (RAL 9010) 45x20 Module for 2 Snap-In Connectors for Single Gang 60x45 Cover Plate Part Number: N x20mm Module for up to 2 copper Snap-In connectors Suitable for use in Single Gang Cover Plate N Use up to 2 modules per 60x45mm Cover Plate with one 45x20mm Blanking Module Plastic material is UL 94V0 Color: White (RAL 9010) 45x20 Blanking Module for Single Gang 60x45 Cover Plate Part Number: N x20mm Blanking Module For Single Gang 60x45mm Cover Plate Install in center position when used with two 45x20mm Connector Modules Plastic material is UL 94V0 Color: White 27

30 CABLE MANAGEMENT Part Number: N BK 1U Letterbox Patch Guide, Black Allows storage and management of copper and fiber patch cords Open structure with rings for easy access 8cm depth Central letterbox holes allow excess cordage to be posted inside the rack Black paint finished metal Part Number: N BK 1U Universal Patch Guide With Front Cover, Black Allows storage and management of copper and fiber patch cords 8cm depth Cover for tidy cabinet look Black paint finished metal Part Number: N BK 1U Patch Guide With Rings, Black Allows storage and management of copper and fiber patch cords Open structure with rings for easy access 8cm depth Black paint finished metal Also available in White P/N N Part Number: N BK 1U Blank Panel, Black 19in Blank Panel to fill empty cabinet space Also available in White P/N N

31 Angled Blank Panel, Black, 1U Part Number: N in Blank Panel to fill empty cabinet space Angled Panel Cover, Black Part Number: N Used to close the triangular gap formed at the top of a stack of LANmark Angled Panels to prevent items falling behind the panels and to enhance the appearance of the finished installation Angled Pass-Through, Black, 2U Part Number: N The 2U Angled Pass-Through is designed to match the LANmark Angled Panels and to provide a means for patch cables to cross from side to side in a rack while maintaining rack aesthetics Overhead Patching Frame, 4U Part Number: N in 4U overhead frame Ideal in data centers Designed to host both copper and fiber cabling Metal construction Straight or angled position Pair of Patch Cord Management Hooks for Overhead Patching Frame, 4U Part Number: N Required to guide patch cords on both sides of the frame Easy to mount with 2 screws and cage nuts Up to 3 hooks on each side. Black flexible plastic Black flexible plastic 29

32 TOOLS AND ACCESSORIES Part Numbers: N , N , N N N N Keystone Clips Adapter allowing LANmark Snap-In connectors to fit the Keystone format - blue clip required for Essential Faceplate use Plastic clips for all LANmark connectors - Red Clip for aperture heights mm for wall thicknesses mm - Blue Clip for aperture heights mm for wall thicknesses mm - Yellow Clip for aperture heights 19.7mm for wall thicknesses mm Part Number: N XXX XXX = BLA (Black), BLU (Blue), DGR (Dark Green), GRE (Green) ORA (Orange), RED (Red), YEL (Yellow), WHI (White) LANmark Colored Shutters Available in 8 colors: White, Black, Blue, Red, Dark Grey, Dark Green, Yellow, Orange Can be used to replace standard black or white shutters on LANmark Snap-In patch panels, outlet modules and zone distribution boxes Suitable for differentiation between various services by color coding, throughout the entire channel Packed in bags of 100 Part Number: N Hook & Loop Cable Strap, 25m Roll High-quality self gripping cable tie Dark Grey strap with orange Nexans logo Reusable multiple times Recommended to bundle and tie both copper and optical fiber data cables Reduces strain on cables compared to traditional cable fasteners 20mm width 25m roll Part Number: N Comfort Tool Facilitates smooth termination of all LANmark Snap-In connectors Allows re-opening of all LANmark connectors allowing retermination 30

33 ZONE DISTRIBUTION BOXES ZD Box 12 Snap-In, White Part Number: N For use as consolidation point Compatible with all LANmark Snap-In connectors 12 numbered Snap-In ports with shutters Cable entry knock-outs Easy to install Solid metal construction ZD Box 6 Snap-In, White Part Number: N For use as consolidation point Compatible with all LANmark Snap-In connectors 6 numbered Snap-In ports with shutters Cable entry from the back Intregrated cable strain relief Multiple mounting options Solid metal construction Also available in black N BK Ruggedized Lockable ZD Box, White Part Number: N For use as consolidation point Compatible with all LANmark Snap-In connectors 12 numbered Snap-In ports with shutters Easy to install Ruggedized design for industrial and secure environments Lockable with key (supplied) Ruggedized Lockable ZD Box Foot, White Part Number: N Foot for LANmark Ruggedized ZD Box Raises ZD box to 50mm Rugged steel construction 31

34 ESSENTIAL-6 AND ESSENTIAL-5 SYSTEMS Nexans Essential systems are standards based UTP cabling systems designed for cost effective dependability and basic network connectivity in light commercial or MDU applications. Essential systems are eligible for a link warranty only with performance guaranteed to the Category 5e or Category 6 standard. Essential-6 System The Essential-6 system is designed to provide cost effective, enhanced performance for commercial, educational, and health care facilities. The system provides enhanced 1000BASE-T performance and will support PoE up to 60W. Essential-6 Keystone Connector Cat 6 component compliant Cable entry from either side or rear. Wiring according to color code T568B or T568A. Fast and easy termination without punchdown tool. Accepts 24, 23 and 22 AWG solid wire cables. Fits Nexans hardware designed for keystone format. Part Number: N Essential-6 Patch Panel 24 port, UTP Complies to the Category 6 standard 1 U (1.75in) Punchdown termination from the rear UL listed Supplied with screws, cable ties and cable stripping tool Color: Black Part Number: Note: LANmark-6 UTP cable is included as part of the Essential-6 system. See page 18 for LANmark-6 UTP ordering information. Essential-5 System The Essential-5 System provides cost effective voice and data connections in small office, light commercial, or residential/mdu applications. Essential-5 Keystone Connector Cable entry from either side or rear. Wiring according to color code T568B or T568A. Termination with 110 or LSA+ punchdown tool. Accepts 24, 23 and 22 AWG solid wire cables. Fits Nexans hardware designed for keystone format. Also available in a snap-in format for use in LANmark series hardware Color: White Part Number: N Essential-5 Snap-In Part Number: N

35 Essential-5 Patch Panel, 24 Port UTP 1U (1.75in) 110 punchdown termination from the rear UL listed Supplied with cable ties and cable stripping tool Color: Black Part Number: N Essential-5e Cable Plenum - NFPA 262, CMP UL listed Supports most data and voice applications ETL verified to TIA/EIA-568-C.2 Category 5e RoHS compliant Characterized to 350 Mhz Available in economical 1,500ft smartpak Part Number N180.50P93B N180.50P93S N180.50P20B N180.50P20S N180.50P40B N180.50P40S N180.50P70B N180.50P70S N180.50R93B N180.50R93S N180.50R20B N180.50R20S N180.50R70B N180.50R70S N180.50R40B N180.50R40S Description Essential-5e CMP UTP, Dark Grey, Box, 1,000ft Essential-5e CMP UTP, Dark Grey, 1,500ft, smartpak Essential-5e CMP UTP, White, Box, 1,000ft Essential-5e CMP UTP, White, 1,500ft, smartpak Essential-5e CMP UTP, Blue, Box, 1,000ft Essential-5e CMP UTP, Blue, 1,500ft, smartpak Essential-5e CMP UTP, Yellow, Box, 1,000ft Essential-5e CMP UTP, Yellow, 1,500ft, smartpak Essential-5e CMP UTP, Dark Grey, Box, 1,000ft Essential-5e CMP UTP, Dark Grey, 1,500ft, smartpak Essential-5e CMP UTP, White, Box, 1,000ft Essential-5e CMP UTP, White, 1,500ft, smartpak Essential-5e CMP UTP, Yellow, Box, 1,000ft Essential-5e CMP UTP, Yellow, 1,500ft, smartpak Essential-5e CMP UTP, Blue, Box, 1,000ft Essential-5e CMP UTP, Blue, 1,500ft, smartpak 33

36 WORK AREA FACEPLATES Essential Wallplates Essential Keystone Single Gang Wallplate, White Designed for Essential-5 and -6 keystone range 2 or 4 ports in keystone format Textured white finish Top and bottom labelling facilities Supplied with paper labels and windows Screws included Dimensions: 2.77in w x 4.53in h (70.5mm w x 115mm h) Also accepts LANmark Snap-In connectors fitted with a blue keystone clip (page 19) Part Number Description N Port Wallplate N Port Wallplate 34

37 Nexans Cabling Solutions 140 Allstate Pkwy, Markham, ON L3R 0Z7, Canada Tel:

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S

LANmark-7A H i g H - S p e e d C O p p e R S O l u t i O n F O R 4 0 g i g a b i t a p p l i C a t i O n S LANmark-7A High-Speed COPPER Solution For 40 Gigabit Applications LANmark-7A High-Speed Copper Solution For 40 Gigabit and Beyond LANmark-7A copper cabling is able to support higher bandwidths and faster

More information

CONTENT PAGE. Giganet Company Overview... Giganet Category 5e UTP System... Giganet Category 5e UTP Patch Panel... Giganet Category 5e UTP Cable...

CONTENT PAGE. Giganet Company Overview... Giganet Category 5e UTP System... Giganet Category 5e UTP Patch Panel... Giganet Category 5e UTP Cable... GIGANET - MANUFACTURED TO INTERNATIONAL QUALITY STANDARDS COPPER CABLING GIGANET CATEGORY 5e UTP CABLING SYSTEM SYSTEM CATALOG CONTENT PAGE Giganet Company Overview... Giganet Category 5e UTP System...

More information

Cat.8 Shielded Field Termination Plug Description

Cat.8 Shielded Field Termination Plug Description Description RiT s CAT8 Shielded field termination plug are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations.

More information

CSRJ456K. White CSC624PP CSRJ456KB CSRJ456K90

CSRJ456K. White CSC624PP CSRJ456KB CSRJ456K90 PATCH PANELS & JACKS Cat6 Patch Panels Cat6 Keystone RJ45 Jack CSC616PP 16 CSRJ456K CSC624PP 24 CSRJ456KB CSC648PP 48 CSRJ456K90 90 Category 6 patch panel exceeds TIA/EIA-568-B.2-1 Category 6 & ISO 11801

More information

Uniprise Structured Cabling Solutions Guide

Uniprise Structured Cabling Solutions Guide Uniprise Structured Cabling Solutions Guide Exceptional value, proven reliability You re not unrealistic. You re simply looking for a reliable and affordable structured cabling solution; a single portfolio

More information

LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS

LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS LANmark-7A HIGH-SPEED COPPER SOLUTION FOR 40 GIGABIT APPLICATIONS LANmark-7A High-Speed Copper Solution For 40 Gigabit and Beyond LANmark-7A copper cabling is able to support higher bandwidths and faster

More information

Cat.8 Shielded Keystone Jack Description

Cat.8 Shielded Keystone Jack Description Description RiT s CAT8 Shielded Keystone Jacks are cost-effective building blocks for your cabling system. Meticulously engineered to deliver exceptional performance while streamlining installations. Phosphor

More information

IBDN 110 Cross-Connect System

IBDN 110 Cross-Connect System IBDN 110 Cross-Connect System Connecting & Wiring Blocks Cross-Connect Kits Wall Mount Frame Kits Patch Cords Labels & Management Accessories For For A Complete End-to-End 110 Solution what s coming next.

More information

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing

Data sheet. 25Gmodul. Illustrations P/N 130B11-25-E EAN Product specification. Page 1/ Dimensional drawing Page 1/6 Illustrations Dimensional drawing Cut-out See enlarged drawings at the end of document Product specification certified by GHMT according to DTR-11801-9905 for 25GBASE-T in the Channel-Link with

More information

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions

Frequently Asked Questions (FAQs) Siemon 10G ip Solutions Frequently Asked Questions (FAQs) Siemon 10G ip Solutions The world of enterprise cabling is evolving rapidly. Emerging, high-bandwidth services and the adoption of higher speed Ethernet standards, like

More information

Cabling Infrastructure

Cabling Infrastructure Introduction Ethernet Banking on Structured Cabling Technology Drivers Classification of Cables Fibre-optic cable Cables in building Cabling Infrastructure Cabling systems address the networking requirements

More information

Copper Cabling Standards

Copper Cabling Standards Copper Cabling Standards White paper White Paper Copper Cabling Standards v2.0 EN 1 Introduction Standard specifications are the foundation upon which most cabling and networking projects are built. Professionals

More information

SYSTIMAX SCS Power Sum Solution

SYSTIMAX SCS Power Sum Solution SYSTIMAX SCS Power Sum Solution Superior Performance for CAT 5 Networks Realize the Full Potential of Your CAT 5 Network... You ve made a significant investment in your data network. Every component meets

More information

European Data Centre Infrastructure Standards EN series. Rob Cardigan, Senior Product Manager Nexans Cabling Solutions

European Data Centre Infrastructure Standards EN series. Rob Cardigan, Senior Product Manager Nexans Cabling Solutions European Data Centre Infrastructure Standards EN 50600 series Rob Cardigan, Senior Product Manager Nexans Cabling Solutions Scope Presentation Nexans explains the recent standardization process for data

More information

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red.

Field-terminated RJ45 connector with housing. Color housing: gray (RAL 7042). Color termination block: red. FM45 Connector Cat. 6 A IP20, 4P, TIA 568-A/B, 10x R815651 966704105 10 Stk. 090.7437 / ähnliche Abbildung Instruction manual Field-terminated connector with housing. Color housing: gray (RAL 7042). Color

More information

Hitachi Cable America and Optical Cable Corporation STRUCTURED CABLING SOLUTIONS. MOving data

Hitachi Cable America and Optical Cable Corporation STRUCTURED CABLING SOLUTIONS. MOving data Hitachi Cable America and Optical Cable Corporation STRUCTURED CABLING SOLUTIONS TM MOving data TM MOving data Just as a water infrastructure is essential to modern life, information is critical to the

More information

Tarleton State University. Specifications

Tarleton State University. Specifications Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication

More information

Data sheet C6 A modul 90 jack

Data sheet C6 A modul 90 jack Illustrations Dimensional drawing Cut-out Page 1/7 See enlarged drawings at the end of document Product specification modular Cat.6 A termination unit RJ45 mounting version: module, 90 cable feed solid,

More information

Modular plugs, accessories and tooling

Modular plugs, accessories and tooling Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for

More information

How You Can Optimize Passive Optical LAN Through Structured Cabling

How You Can Optimize Passive Optical LAN Through Structured Cabling How You Can Optimize Passive Optical LAN Through Structured Cabling Author: Stephane Bourgeois Director Technology Strategy Table of Contents Overview 1 What is POLAN? 1, 2 Deploying a POLAN 2 The Benefits

More information

UTP Cat 5e cable (200 MHz) (PVC sheath)

UTP Cat 5e cable (200 MHz) (PVC sheath) JetLan is the only structured cabling system that includes all the passive components required for the installation or adaptation of your data network, as we include all the different types of high performance

More information

Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print"

Industry Standards in ICT Enabled Projects Reading and Applying the Fine Print Industry Standards in ICT Enabled Projects Reading and Applying the "Fine Print" Gautier Humbert, RCDD Standards Coordinator Legrand Digital Infrastructures Gautier Humbert, RCDD BICSI District Chair Mainland

More information

Voice Integration Overview

Voice Integration Overview Voice Integration Overview 010.2936 Intelligent voice integration Highest packing density Modular design Efficient and tool-free connection technique Comprehensive product range Ingenious labelling system

More information

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India

Enterprise Network Test Strategies for Network Availability and Performance. A Sitaramaiah Director Fluke Networks India Enterprise Network Test Strategies for Network Availability and Performance A Sitaramaiah Director Fluke Networks India 1 Why is Enterprise Network Testing becoming increasingly important? IT is increasingly

More information

Connected & Efficient Building. Field Application Engineer - Kutlugün Sürmeli CommScope

Connected & Efficient Building. Field Application Engineer - Kutlugün Sürmeli CommScope Connected & Efficient Building Field Application Engineer - Kutlugün Sürmeli CommScope Low Voltage Over Twisted Pair Revolution Desktop Voice and Data WiFi Access Control Security Cameras Occupancy Sensors

More information

RapidNet. 6A Solutions

RapidNet. 6A Solutions RapidNet 6A Solutions NETWORK CABLING SOLUTIONS RapidNet 6A Solutions High-performance, versatile pre-terminated network cabling RapidNet patented pre-terminated systems offer high-performance network

More information

Data sheet C6 A modul 1 port 180 M AP pure white

Data sheet C6 A modul 1 port 180 M AP pure white Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification surface-mount termination unit with C6modul 180 certified to GHMT Cat.6 re-embedded PVP component

More information

ORTRONICS SNAP CLARITY TERMINATED COPPER CABLING SYSTEMS & PORT REPLICATION. designed to be better.

ORTRONICS SNAP CLARITY TERMINATED COPPER CABLING SYSTEMS & PORT REPLICATION. designed to be better. ORTRONICS CLARITY SNAP TERMINATED COPPER CABLING SYSTEMS & PORT REPLICATION designed to be better. QUICK AND RELIABLE DATA CENTER INSTALLATIONS ARE A SNAP WITH THE LATEST INNOVATION FROM LEGRAND. 2 In

More information

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE

OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE OMEGA MODULAR PATCH PANEL EMPTY ENCLOSURE The Omega MPP enclosure is based on a 19" frame, with 4 empty module slots for MPP modules. Highly flexible : any mix between twisted pair and optical fiber modules.

More information

Siemon PON Fiber Cabling Solutions

Siemon PON Fiber Cabling Solutions Siemon PON Fiber Cabling Solutions WWW.SIEMON.COM 8 Siemon Enterprise PON Fiber Cabling Solution Siemon Enterprise Passive Optical Network (PON) Fiber Cabling Solution improves the modularity, flexibility

More information

Family of Cords SYSTIMAX. Structured Cabling Systems. Quality Stranded and Solid Cords That Connect Data and Voice Circuits

Family of Cords SYSTIMAX. Structured Cabling Systems. Quality Stranded and Solid Cords That Connect Data and Voice Circuits SYSTIMAX Structured Cabling Systems Family of Cords Quality Stranded and Solid Cords That Connect Data and Voice Circuits Lucent Technologies Family of Stranded Cords includes 110 patch, modular and adapter

More information

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards

Anticipating Cat 8 Agenda. Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards Anticipating Cat 8 Agenda Cat 8 Overview Cat 8 Customer Design Considerations Testing Procedures and Standards What is Cat 8? Next Generation Copper Cabling 25G and 40G data rates over twisted pair copper

More information

Role of Copper Cabling in Datacentres

Role of Copper Cabling in Datacentres Role of Copper Cabling in Datacentres White paper White Paper Role of Copper Cabling in Datacentres v1.0 EN 1 Introduction Structured cabling certainly has its place in contributing to the making of a

More information

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-Speed Copper Solution For 10 Gigabit Applications From the beginning on, 10G Ethernet was intended to retain backwards

More information

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure

Power Over Ethernet with Panduit Copper Cabling. How To Create More Meaningful Connections With The Highest Performing Infrastructure Power Over Ethernet with Panduit Copper Cabling How To Create More Meaningful Connections With The Highest Performing Infrastructure Introduction Increasing usage of Power over Ethernet (PoE) represents

More information

The Quality Connection. LEONI QuickLine Class E Cabling Solution

The Quality Connection. LEONI QuickLine Class E Cabling Solution The Quality Connection LEONI QuickLine Class E Cabling Solution QuickLine 2 Content Infrastructure & Datacom Solutions from a single source Shielded solution, keystone 4 Shielded solution, punch-down 5

More information

E-DAT C6A. The compact connection system of course with Cat.6A

E-DAT C6A. The compact connection system of course with Cat.6A E-DAT C6A The compact connection system of course with Cat.6A Intelligent system solution for structured cabling Nowadays the need for high data transfer rates is enormous. This not only applies to public

More information

Category 5e Solutions

Category 5e Solutions Introduction... 5.2 Cable... 5.3 Patch Panels... 5.4 Modules... 5.5 Patch Cords... 5.8 Mutos and Consolidation Points... 5.13 Outlets... 5.14 www.adckrone.com AUS 1800 801 298 NZ 0800 657 663 5.1 Introduction

More information

R&Mfreenet Advanced Cat 6A Shielded Connection Module

R&Mfreenet Advanced Cat 6A Shielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6A Connection Module The R&Mfreenet Cat 6A shielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions and

More information

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring

Cabling to support ac and beyond. Nate Herring Sr. Product Manager Hubbell Premise Wiring Cabling to support 802.11ac and beyond Nate Herring Sr. Product Manager Hubbell Premise Wiring IP Traffic Continues to Increase Globally, IP traffic will grow 3-fold from 2014 to 2019, a compound annual

More information

Cat 6 (500 MHz) UTP solid cable (PVC sheath)

Cat 6 (500 MHz) UTP solid cable (PVC sheath) JetLan is the only structured cabling system that includes all the passive elements required by the installation or modification of your data networks, as it offers all the options for high performance

More information

Next Generation Wireless

Next Generation Wireless PERFORM BEYOND EXPECTATIONS A BERK-TEK WHITE PAPER Next Generation Wireless Evolution, Advancements, and Considerations for Deployment WWW.BERKTEK.COM Page 2 Table of Contents Next Generation Wireless:

More information

Laying the groundwork for a new level of Power over Ethernet

Laying the groundwork for a new level of Power over Ethernet Laying the groundwork for a new level of Power over Ethernet October 2018 Table of contents Laying the groundwork for a new level of Power over Ethernet...3 PoE basics...4 PoE standards development...5

More information

The SYSTIMAX GigaSPEED X10D solution. The infrastructure modern enterprises and data centers depend on

The SYSTIMAX GigaSPEED X10D solution. The infrastructure modern enterprises and data centers depend on The SYSTIMAX GigaSPEED X10D solution The infrastructure modern enterprises and data centers depend on Extend your network s capabilities with GigaSPEED X10D Fast enough just isn t fast enough anymore.

More information

STAR. Data Center High Density Connectivity Solution

STAR. Data Center High Density Connectivity Solution STAR Data Center High Density Connectivity Solution 2 STAR Solution Illustration Reach for the STAR: Data Center Connectivity that achieves new heights! Fibernet is proud to introduce the new STAR series,

More information

exp-s1110pe PoE+ Gigabit Ethernet Extenders

exp-s1110pe PoE+ Gigabit Ethernet Extenders perle.com https://www.perle.com/products/10-100-1000-poe+-ethernet-extender.shtml exp-s1110pe PoE+ Gigabit Ethernet Extenders 10/100/1000 PoE+ Ethernet Copper Extenders Extends 10/100/1000Base-T up to

More information

Implementation considerations for cabling supporting remote powering

Implementation considerations for cabling supporting remote powering Implementation considerations for cabling supporting remote powering Table of contents Background...3 Advantages of remote powering using communications cabling...4 CommScope implementation considerations

More information

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS.

Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications. Robert Y. Faber Jr., RCDD/NTS. Cable Sharing: An ANSI & ISO Recognized Solution for High Density, Low-Speed Applications Broadband High-Speed LAN Voice Robert Y. Faber Jr., RCDD/NTS Minimum Port Recommendations TIA/EIA-568-B.1 2 outlets

More information

Government of Prince Edward Island Structured Cabling Standards August 24, 2009

Government of Prince Edward Island Structured Cabling Standards August 24, 2009 Government of Prince Edward Island Structured Cabling Standards August 24, 2009 Emerging technologies dictate that it is no longer allowable to simply integrate various manufacturers components into a

More information

CERTIFICATION PLUS SM

CERTIFICATION PLUS SM CERTIFICATION PLUS SM SYSTEM WARRANTY PROGRAM Panduit Warranty Guide PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction & Installation

More information

Bonding and grounding NETCONNECT copper cabling systems

Bonding and grounding NETCONNECT copper cabling systems White paper Bonding and grounding NETCONNECT copper cabling systems A complete review of bonding and grounding for copper twisted-pair cabling systems www.commscope.com 1 Taking the guesswork out of grounding

More information

Light over PoE. Emanuele Colombo Country Manager R&M Italia October 2017

Light over PoE. Emanuele Colombo Country Manager R&M Italia October 2017 Light over PoE Emanuele Colombo Country Manager R&M Italia October 2017 Content Introduction Development of PoE Zone cabling according EN50173-6 Digital Ceiling Solution R&M proposals for Digital Ceiling

More information

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO

Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO Cabling Standards Office of the Chief Information Officer Technical Note: IT-960-TN14 Effective: 05/25/2006 Last Revised: 02/17/2012 Issuing Office: OCIO 1. Purpose CABLING STANDARDS This technical note

More information

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation

Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Testing and deployment of direct attach and the impact of category 8 Thursday, 10 August 2017, 3:50-4:40 P.M. Jamey Calloway, RCDD Product Management Specialist Optical Cable Corporation Overview Traditional

More information

DATACOM CABINETS SOLUTION GUIDE

DATACOM CABINETS SOLUTION GUIDE DATACOM CABINETS SOLUTION GUIDE designed to be better. LEGRAND S CABINET OFFERING Legrand cabinets are designed with cable management, airflow management and effortless installation to meet all network

More information

PCS PATCH CORD SOLUTIONS PATCH CORD SOLUTIONS

PCS PATCH CORD SOLUTIONS PATCH CORD SOLUTIONS Structured Cabling Solutions PCS PATCH CORDS. HiPerlink 6 Colored Patch Cords- 35,36 HiPerlink 1000 Category 5e Colored Patch Cords- 35,36 Snap-in Icons 36 ScTP Category 5 Patch Cord 37 Category 5 Colored

More information

3M Telecommunications. Solutions for Networks. Volition 10G Copper Solutions. Innovation

3M Telecommunications. Solutions for Networks. Volition 10G Copper Solutions. Innovation 3M Telecommunications Solutions for Networks Volition 10G Copper Solutions Innovation Volition 10G Copper Solutions In less than 10 years, the speed of local area networks (LAN) has gone from less than

More information

Compact Module. Category 6 UTP Cabling System

Compact Module. Category 6 UTP Cabling System Compact Module Suitable for Gigabit Ethernet applications Shallow design requires minimal back-box depth Interchangeable with all other Euro modules and quarter blanks Fits all standard Euro faceplates

More information

Cabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT

Cabinet. DT-NCW NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT Cabinet DT-NCW-2-6409 NETWORK CABINET WALL MOUNT 9U - 60(W)x45(D)x46(H) 71,50 +VAT SPCC cold rolled steel One section wall mount rack Fan, shelf for optional DT-NCW-2-6412 NETWORK CABINET 12U - 60(W)x45(D)x59(H)

More information

TIA/EIA 568A Sub-system HORIZONTAL CABLING

TIA/EIA 568A Sub-system HORIZONTAL CABLING TIA/EIA 568A Sub-system HORIZONTAL CABLING Horizontal Cabling WA 100(120)Ω CAT 3 TP TP 100(120)Ω CAT 5 150Ω STP-A 62.5(50)/125µ FIBER HC/FD WA Horizontal Media Considerations UTP/FTP Consider bandwidth,

More information

2nd Edition. Product overview. Components for class E A. Cabling systems. Future-proof 10GBase-T solutions for your IT infrastructure

2nd Edition. Product overview. Components for class E A. Cabling systems. Future-proof 10GBase-T solutions for your IT infrastructure 2nd Edition Product overview Components for class E A Cabling systems with RJ45 Module MS-K Plus Cat.6 A (IEC) Future-proof 10GBase-T solutions for your IT infrastructure Copper Cabling system For the

More information

With the publication. Make the right connection: Bonding a shielded system. installation

With the publication. Make the right connection: Bonding a shielded system. installation Make the right connection: Bonding a shielded system installation With the publication of the IEEE 802.3an 10GBase-T standard in 2006, Augmented Category 6 (i.e., Category 6A) cabling systems are being

More information

A Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks

A Full Range for Different Applications The STG2000 modules offer three different types of IDC circuits. The Network of Networks The Network of Networks 3M High Density Cross-Connect Modules STG2000 Series The 3M High Density Cross-Connect Modules STG2000 Series are IDC copper cross-connects that can be used in a wide variety of

More information

9/27/04 cci Cablecom Inc. 1

9/27/04 cci Cablecom Inc. 1 cci Cablecom Inc. 1 CCI Cablecom Inc. is a privately held, women owned corporation headquartered in Aurora, CO. We manufacture a variety of voice and datacom products. Cable applications Include: Local

More information

LANmark p h y s i c a l i n f r a s t r u c t u r e s o l u t i o n s s e c u r e y o u r i n f o r m a t i o n f l o w

LANmark p h y s i c a l i n f r a s t r u c t u r e s o l u t i o n s s e c u r e y o u r i n f o r m a t i o n f l o w LANmark p h y s i c a l i n f r a s t r u c t u r e s o l u t i o n s s e c u r e y o u r i n f o r m a t i o n f l o w The average financial loss when business-critical systems fail is 90,000 per hour.

More information

Data sheet C6 A modul 2 port 180 M UP pure white

Data sheet C6 A modul 2 port 180 M UP pure white Illustrations Dimensional drawing Page 1/7 See enlarged drawings at the end of document Product specification flush-mounted termination unit with C6 A modul 180 certified to GHMT Cat.6 A re-embedded PVP

More information

LAN CABLING SYSTEMS 2018

LAN CABLING SYSTEMS 2018 LAN CABLING SYSTEMS 2018 Table of content Nexans 9 Nexans UK 10 LAN Cabling Systems 11 Copper LAN Systems 12 Category 5e 13 LANmark 5 Shielded Cable 14 LANmark 5 U/UTP Cable 16 LANmark 5 Snap In connector

More information

ex-s1110-xt Gigabit Ethernet Extenders

ex-s1110-xt Gigabit Ethernet Extenders ex-s1110- Gigabit Ethernet Extenders perle.com/products/10-100-1000-industrial-ethernet-extender.shtml 10/100/1000 Industrial Temperature Copper Extender Extends 10/100/1000Base-T Ethernet up to 10,000

More information

The Power of PoE: Converging Power and Control of Intelligent Devices

The Power of PoE: Converging Power and Control of Intelligent Devices The Power of PoE: Converging Power and Control of Intelligent Devices Amir Sekhavat Global Director, Copper Product Management and Enterprise Market Development Superior Essex Objectives What drives the

More information

Saving Critical Space. Cable Management Solutions

Saving Critical Space. Cable Management Solutions Saving Critical Space Cable Management Solutions Cable Management Innovation that Saves Space where You Need It Most Enterprise telecom rooms have traditionally housed telecommunications equipment, cable

More information

Energy Saving Best Practices

Energy Saving Best Practices Energy Saving Best Practices BICSI Meeting West Kingston, RI 16 October 2008 Vinnie Jain, CDCP Advanced Marketing Manager Ortronics/Legrand VJ-1July08 IT Spending on the Rise 600 500 400 $B 300 200 100

More information

GIGANET - MANUFACTURED TO INTERNATIONAL QUALITY STANDARDS COPPER & FIBRE GIGANET FACEPLATES & ACCESSORIES SYSTEM CATALOG.

GIGANET - MANUFACTURED TO INTERNATIONAL QUALITY STANDARDS COPPER & FIBRE GIGANET FACEPLATES & ACCESSORIES SYSTEM CATALOG. GIGANET - MANUFACTURED TO INTERNATIONAL QUALITY STANDARDS COPPER & FIBRE GIGANET FACEPLATES & ACCESSORIES SYSTEM CATALOG CONTENT PAGE Giganet Company Overview... 1 Giganet Faceplates Overview and Keystone

More information

2,5 and 5GBASE-T A Study of Development and Deployment. White Paper January 2017

2,5 and 5GBASE-T A Study of Development and Deployment. White Paper January 2017 2,5 and 5GBASE-T A Study of Development and Deployment White Paper January 2017 For more than fifteen years, Category 5e cabling has provided a robust channel for 100BASE-TX and 1000BASE-T to operate.

More information

LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S

LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S LANmark-6A H I G H - S P E E D C O P P E R S O L U T I O N F O R 1 0 G I G A B I T A P P L I C A T I O N S LANmark-6A High-Speed Copper Solution For 10 Gigabit Applications 10 Gigabit (10G) per second

More information

HIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters

HIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters HIGH DENSITY DATA CENTER CABLING GUIDE Optics DACs Cables Cable Management Fiber TAPs Media Converters PROVIDING MTP CABLING SOLUTIONS FOR THE SMART DATA CENTER. APPROVED NETWORKS SETS THE STANDARD The

More information

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications

LANmark-6A. High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-speed Copper Solution For 10 Gigabit Applications LANmark-6A High-speed Copper Solution For 10 Gigabit Applications 10 Gigabit (10G) per second is the newest, fastest-growing data rate

More information

Contents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06

Contents. Structured Cabling Solutions. LAN Cables Patch Cords Connectors Patch Panels... 06 Contents Cat6 Structured Cabling Solutions U/UTP Cabling Solutions Structured Cabling Solutions LAN Cables... 03 Patch Cords... 04 Connectors... 05 Patch Panels... 06 U/FTP Cabling Solutions LAN Cables...

More information

Product Bulletin. One Enterprise. One Infrastructure. One Partner. Belden 10GX Pre-Terminated Cabling Systems

Product Bulletin. One Enterprise. One Infrastructure. One Partner. Belden 10GX Pre-Terminated Cabling Systems Product Bulletin PB 293 Belden 10GX Pre-Terminated Cabling Systems Pre-Term Made Easy Save Time and Money Category 6A Compliant No Compromise on Performance and Reliability Green Solution Belden s 10GX

More information

10GBASE-T and. Copper Cabling Choices

10GBASE-T and. Copper Cabling Choices 10GBASE-T and Copper Cabling Choices Agenda Cabling infrastructure planning recommendations Introduction to 10GBASE-T Evaluation of critical parameters What is Siemon 10G ip? Copper cabling recommendations

More information

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module

R&Mfreenet Advanced Cat 6 A Unshielded Connection Module R&Mfreenet Advanced R&Mfreenet Advanced Cat 6 A Connection Module The R&Mfreenet Cat 6 A unshielded connection modules, part of the Advanced cabling system, are ideal for voice, fast data transmissions

More information

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY

PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents

More information

Making Use of Innovative Cabling Technologies to Deliver the Best Preterminated. System for 10G Networks

Making Use of Innovative Cabling Technologies to Deliver the Best Preterminated. System for 10G Networks Not All Pre-Terminated Cabling Systems Are Created Equal Making Use of Innovative Cabling Technologies to Deliver the Best Preterminated Cabling System for 10G Networks Table of Contents Introduction....

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 73 ANSI/TIA/EIA-568-B Cabling Standard In the mid-1980s, consumers, contractors, vendors, and manufacturers became concerned about the lack of specifications relating to telecommunications cabling. Before

More information

Interconnect Product CATALOG Q700

Interconnect Product CATALOG Q700 onents.com Interconnect Product CATALOG Q700 Quest Network Quest Network Warranty Products Warranty Que st Technology International Inc., carries a LIFETIME warranty on all Category- Rated link components

More information

Laying the groundwork for a new level of Power over Ethernet

Laying the groundwork for a new level of Power over Ethernet White paper Laying the groundwork for a new level of Power over Ethernet April 2017 Contents Laying the groundwork for a new level of Power over Ethernet 3 PoE basics 3 PoE standards development 4 Four-pair

More information

ANSI/TIA/EIA-568-B Cabling Standard

ANSI/TIA/EIA-568-B Cabling Standard 83 Pair Numbers and Color Coding The conductors in a UTP cable are twisted in pairs and color coded so that each pair of wires can be easily identified and quickly terminated to the appropriate pin on

More information

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification

Cable Certification. General Testing Criteria (Applies to all cable certification testing) Attachment F Cable Certification General Testing Criteria (Applies to all cable certification testing) 1. RCIT reserves the right to be present during any or all cable testing procedures. The Contractor shall obtain authorization from

More information

Nokia Passive Optical LAN solution

Nokia Passive Optical LAN solution As businesses contemplate how to introduce a new generation of services, improve productivity, lower costs and build a competitive advantage, they are faced with tough decisions about the performance and

More information

Cat.6/5e UTP Patch Panels with 45 Jack

Cat.6/5e UTP Patch Panels with 45 Jack Cat.6/5e UTP Patch Panels with 45 Jack Index TOOL KITS TOOL WIRING CONNECTORS LAN/DATACOMM INSTRUMENT MISCELLANEOUS POWER TOOLS FIBER OPTICS MAGNIFICATION & Our Cat.6/5e patch panels are used for high

More information

FTTE Revisited for New Technologies

FTTE Revisited for New Technologies FTTE Revisited for New Technologies A new look into FTTE design to allow great flexibility as well as compliance to the latest 40G and 100G. Gautier Humbert, RCDD, CDCDP Business Development Manager Eastern

More information

Computer Network Design Guide Existing Systems 1 / 6

Computer Network Design Guide Existing Systems 1 / 6 COMPUTER NETWORK DESIGN GUIDELINE FOR EXISTING SYSTEMS DOCUMENT NUMBER: 16765 APPLICATION: ELEMENTARY, MIDDLE AND HIGH SCHOOL DATE OF ISSUE: 11-27-06 - First Issued NOTES: The attached guideline should

More information

InstaPATCH Cu Cabling Solutions for Data Centers

InstaPATCH Cu Cabling Solutions for Data Centers SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 InstaPATCH Cu Solution Specification 2 Harness Assembly Design 3

More information

3M Category 6 Copper Structured Cabling System

3M Category 6 Copper Structured Cabling System Communication Markets Division 3M Category 6 Copper Structured Cabling System 3M RJ45 Category 6 Jacks UTP PL 3M Copper Patch Cords 3M Copper Patch Panels 3M Faceplates & Wall Outlets 3M Copper Cable 3M

More information

AV-IP System & Components

AV-IP System & Components Product Guide AV-IP System & Components Cost-Effective AV Distribution Systems for Classrooms and Boardrooms We re at the Intersection of AV and IT AV over IP (AV-IP) is the transmission of audio-visual

More information

WELCOME TO THE FUTURE OF CONNECTION AND PROTECTION

WELCOME TO THE FUTURE OF CONNECTION AND PROTECTION WELCOME TO THE FUTURE OF CONNECTION AND PROTECTION At nvent, we believe that safer systems ensure a more secure world. We connect and protect our customers with inventive electrical solutions. Publicly

More information

Modular plugs, accessories and tooling

Modular plugs, accessories and tooling Modular plugs, accessories and tooling Introducing the new Cat 6A/6 modular plugs, slim-line boots and color clips CommScope modular plug portfolio CommScope offers a vast portfolio of Modular Plugs for

More information

The AMP NETCONNECT Category 6 Cabling System

The AMP NETCONNECT Category 6 Cabling System The AMP NETCONNECT Category 6 Cabling System 2 Table of Contents TABLE OF CONTENTS...3 PERSPECTIVE...4 WHY INSTALL NEXT GENERATION CABLING SYSTEMS?...4 MEGAHERTZ VS. MEGABITS...4 PLANNING FOR THE FUTURE...5

More information

ORTRONICS CLARITY HIGH DENSITY COPPER SOLUTION MAXIMIZE YOUR CABLING DENSITY, REDUCE YOUR FOOTPRINT. designed to be better.

ORTRONICS CLARITY HIGH DENSITY COPPER SOLUTION MAXIMIZE YOUR CABLING DENSITY, REDUCE YOUR FOOTPRINT. designed to be better. ORTRONICS CLARITY HIGH DENSITY COPPER SOLUTION MAXIMIZE YOUR CABLING DENSITY, REDUCE YOUR FOOTPRINT designed to be better. Legrand HDJ patented, recessed angled modular patch panels combine with Legrand

More information

The Internet of Everything (IoE)

The Internet of Everything (IoE) The Internet of Everything (IoE) Agenda The Internet of Everything is coming, In 2018, How do I Prepare? Why Cable Matters Conclusions Here s what I know about the future: it happens as a result of what

More information

PERFORM BEYOND EXPECTATIONS GLOBAL LEADERSHIP IN CABLING TECHNOLOGY

PERFORM BEYOND EXPECTATIONS GLOBAL LEADERSHIP IN CABLING TECHNOLOGY PERFORM BEYOND EXPECTATIONS GLOBAL LEADERSHIP IN CABLING TECHNOLOGY The Berk-Tek Optimized Cabling Platform: Keeping business in motion. To keep your business in top form, you need an infrastructure second

More information