Service Description blizznetdarkfiber Version: 2.0

Size: px
Start display at page:

Download "Service Description blizznetdarkfiber Version: 2.0"

Transcription

1 Service Description blizznetdarkfiber Version: 2.0

2 Inhalt: 1. About Wien Energie and blizznet Basic Services Prerequisites Physical availability Construction prerequisites/space requirements Legal prerequisites Access Network Connection Point (NCP) Provisioning times Service handover Monitoring Service management & SLA Technical service data... 3 Fibre data (single mode fibre)... 3 Splice connections... 3 Socket / Patch Connection... 3

3 1. About Wien Energie and blizznet Wien Energie has been operating a telecommunications network deploying all common technologies for more than twenty years. Glass fibres have been laid for this purpose since You will find amongst our customers nearly all telecommunications and internet companies represented in Vienna in addition to the Wiener Stadtwerke and the Municipality of Vienna. Wien Energie offers with the blizznet brand a highly available glass fibre network within the Vienna city area, the basis of which is formed by a network of over 2,000 km of optical fibre cables. 2. Basic Services The blizznetdarkfiber product links two customer locations using glass fibre. Several fibre links are strung together using splices or patches to form a complete connection without the use of active equipment. The prerequisite for the provision of the specified services is exclusive realization using the Wien Energie network infrastructure. A redundant connection of customer premises is optionally possible. This service description applies solely to enterprises pursuant to Article 1 of the Austrian Consumer Protection Act. 3. Prerequisites 1.1. Physical availability blizznetdarkfiber is generally available where Wien Energie can provide a glass fibre connection Construction prerequisites/space requirements The installation site of the equipment provided by Wien Energie to the customer is to be clean, dry, safe and sufficiently ventilated. In particular the customer is to ensure at their own expense that the following outline conditions are satisfied: Space requirements: 1 U (rack unit) in a 19 rack Ambient temperature: 0 C to +40 C Relative humidity: 5% to 85% (non-condensing) The above parameters refer to the handover via patching (=standard). The prerequisites for alternative variants are specified in the respective offer Legal prerequisites Please refer to the General Terms and Conditions of Wien Energie GmbH 1 for details. 4. Access The General Terms & Conditions regulate access to Wien Energie equipment/network connection point (NCP) at the customer s. 1 These can be downloaded at Energie.at and/or Seite 1 von 3

4 5. Network Connection Point (NCP) The connection socket at the customer s is deemed the network connection point (NCP). All network equipment up to this point is deemed to be within the sphere of responsibility of Wien Energie. This does not apply to components and connections provided by the customer. 6. Provisioning times The provisioning times depend on the requested locations and will be specified in the respective offer. The General Terms & Conditions regulate details thereof. 7. Service handover Wien Energie delivers to the customer the service handover notification. This notification has to cover at least the following parameters: Connection numbers Measurements record of the length and attenuation properties of the connection using OTDR measurement (one sided) Other relevant information 8. Monitoring The Network Operation Centre (NOC) monitors the Wien Energie network 24x7x 365/. 9. Service management & SLA Please refer to the blizznetsla (Service Level Agreement) for details regarding faults, maintenance, guaranteed availability, points of contacts and escalation levels. It should be noted that faults in a Dark Fiber connection can only be identified indirectly (e.g. through the failure of other connections on the same fibre link) by Wien Energie. Unless otherwise expressly agreed the SLA STANDARD category is deemed agreed. Seite 2 von 3

5 10. Technical service data The values of the desired connection depend on the length and number of patch and splice connections. Wien Energie will state the relevant values such as length and attenuation of the complete connection in the respective offer. Fibre data (single mode fibre) Type: ITU-T G.652 Dimensions: Diameter of mode field d (as per Petermann II) for 1310 nm 9.2 µm ± 0.40 µm for 1550 nm 10.5 µm ± 1.0 µm Mode field eccentricity 0.5 µm Transmission and optical properties Damping at 1310 nm 0.36 db/km Damping at 1550 nm 0.22 db/km Chromatic dispersion at nm 3.5 ps/(nm * km) Chromatic dispersion at 1550 nm 18 ps/(nm * km) Polarisation mode dispersion 0.2 ps/(km) Cut-off wavelength (relative to RTM) for the fibres λ cf in the nm range for the fibres in the cable λ ccf 1250 nm Point defect at pulse width 10 ns nm 0.05 db Dispersion zero point Increase in dispersion at zero point ps/(nm² * km) Splice connections The arithmetic mean value of all splice attenuation of a fibre between the customer locations to be connected is 0.1 db per cable splice. If the connection comprises 5 cable splices the mean value is 0.15 db per splice. Socket / Patch Connection Standard socket Insertion loss: Return loss Loss per patch FC/PC 0.2 db at 1550 nm 40 db at 1550 nm maximum1db (Ø 0.7 db) The standard network connection point at the customer s is executed as an FC/PC socket. Alternative variants are optionally possible at the request of the customer. There may be an additional charge. Seite 3 von 3

Service description blizzneteos Version: 2.1

Service description blizzneteos Version: 2.1 Service description blizzneteos Version: 2.1 Leistungsbeschreibung_EoS_V2.1_en.docx Contents: 1. About Wien Energie & blizznet... 1 2. Basic Services... 1 2.1. Bandwidths... 1 3. Prerequisites... 1 3.1.

More information

Service description blizznetvll and blizznetvpls Version: 3.3

Service description blizznetvll and blizznetvpls Version: 3.3 Service description blizznetvll and blizznetvpls Version: 3.3 Leistungsbeschreibung_VLL&VPLS_V3.3_en.docx Contents: 1. About Wien Energie & blizznet... 1 2. Basic Services... 1 2.1. blizznetvll... 1 2.2.

More information

Specification of Services blizznetbusinessinternet Version: 2.0

Specification of Services blizznetbusinessinternet Version: 2.0 Specification of Services blizznetbusinessinternet Version: 2.0 Bank information: Wien Energie GmbH FN 215854h UniCredit Bank Austria AG Thomas-Klestil-Platz 14 1030 Vienna Commercial Court, Vienna Account

More information

Specification for Dispersion Slope Compensating Module for LEAF Transmission Fiber LEAF-DK

Specification for Dispersion Slope Compensating Module for LEAF Transmission Fiber LEAF-DK Specification for Dispersion Slope Compensating Module for LEAF Transmission Fiber LEAF-DK Version 1.4 2013-03-18 1 Ordering information Order code format: LEAFDK-S-xxx-yy-zz Mechanical option Connector

More information

Specification for Dispersion Slope Compensating Module for TW-RS Transmission Fiber in the C-band TWRS-DK

Specification for Dispersion Slope Compensating Module for TW-RS Transmission Fiber in the C-band TWRS-DK Specification for Dispersion Slope Compensating Module for TW-RS Transmission Fiber in the C-band TWRS-DK Version 1.12 2015-09-09 1 Ordering information Order code format: TWRSDK-S-xxx-yy-zz Mechanical

More information

Specification for Dispersion Slope Compensating Module for SMF Transmission Fiber SMF-DK

Specification for Dispersion Slope Compensating Module for SMF Transmission Fiber SMF-DK Specification for Dispersion Slope Compensating Module for SMF Transmission Fiber SMF-DK Version 1.45 2017-04-28 0 Ordering information Order code format: SMFDK-S-xxx-yy-zz Mechanical option Connector

More information

AAPT Business Dark Fibre. Service Schedule

AAPT Business Dark Fibre. Service Schedule AAPT Business Dark Fibre Service Schedule This Service Schedule forms part of the Agreement between Us and You and cannot be used as a stand-alone agreement. Any terms defined in the Service Agreement

More information

AAPT Business Dark Fibre. Service Schedule

AAPT Business Dark Fibre. Service Schedule AAPT Business Dark Fibre Service Schedule This Service Schedule forms part of the Agreement between Us and You and cannot be used as a stand-alone agreement. Any terms defined in the Service Agreement

More information

Sumitomo Fiber Specification SE-7** Non-Zero Dispersion Shifted Single-Mode Fiber. PureMetro SM Optical Fiber, TIA Type Ivd, ITU-T G.

Sumitomo Fiber Specification SE-7** Non-Zero Dispersion Shifted Single-Mode Fiber. PureMetro SM Optical Fiber, TIA Type Ivd, ITU-T G. Sumitomo Fiber Specification SE-7** Non-Zero Dispersion Shifted Single-Mode Fiber PureMetro SM Optical Fiber, TIA Type Ivd, ITU-T G.655 Issued: January 2006 CONTENTS 78 Alexander Drive, Research Triangle

More information

2DXX Optical Modules with Diagnostic Analog Output

2DXX Optical Modules with Diagnostic Analog Output 2DXX Optical Modules with Diagnostic Analog Output The diagnostic analog output is used to indicate the strength of an incoming light signal to the receiver (RX) input on the optical module. The sensitivity

More information

Chorus UFB Services Agreement. Direct Fibre Access Services: Service Description for Jumpering Service

Chorus UFB Services Agreement. Direct Fibre Access Services: Service Description for Jumpering Service Chorus UFB Services Agreement Direct Access Services: Service Description for Jumpering Service Reference Offer June 2017 Page 1 of 7 1. Interpretation 1.1 References to clauses or sections are references

More information

Sumitomo Fiber Specification SE-5** PureBand Single-Mode Fiber. Zero Water Peak (ZWP) Attenuation Optical Fiber, ITU G.

Sumitomo Fiber Specification SE-5** PureBand Single-Mode Fiber. Zero Water Peak (ZWP) Attenuation Optical Fiber, ITU G. Sumitomo Fiber Specification SE-5** PureBand Single-Mode Fiber Zero Water Peak (ZWP) Attenuation Optical Fiber, ITU G.652D TIA Type IVa Issued: March 2009 78 Alexander Drive, Research Triangle Park, NC

More information

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service Ultrafast Fibre UFB s Agreement Description for Central Office and POI Co-location 1 Interpretation 1.1 The Central Office and POI Co-location described in this Description will be available from the date

More information

Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service

Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service Chorus UFB Services Agreement Service Description for Central Office and POI Co-location Service 1 Interpretation 1.1 The Central Office and POI Co-location Service described in this Service Description

More information

SERVICE TERMS AND SLA FOR LEASE OF DARK FIBER

SERVICE TERMS AND SLA FOR LEASE OF DARK FIBER SERVICE TERMS AND SLA FOR LEASE OF DARK FIBER Dark Fiber Lease. These are the service terms and service level agreement for the lease of Global Crossing Dark Fiber which apply to the provision of Dark

More information

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service

Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service Ultrafast Fibre UFB Services Agreement Service Description for Central Office and POI Co-location Service 1 Interpretation 1.1 The Central Office and POI Co-location Service described in this Service Description

More information

Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service

Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service Northpower Fibre UFB Services Agreement Service Description for Direct Fibre Access Service 1 Interpretation 1.1 The Direct Fibre Access Service described in this Service Description will be available

More information

Singlemode vs Multimode Optical Fibre

Singlemode vs Multimode Optical Fibre Singlemode vs Multimode Optical Fibre White paper White Paper Singlemode vs Multimode Optical Fibre v1.0 EN 1 Introduction Fibre optics, or optical fibre, refers to the medium and the technology associated

More information

Advances in Fiber Tier 2 Enterprise & Data Center Testing

Advances in Fiber Tier 2 Enterprise & Data Center Testing Advances in Fiber Tier 2 Enterprise & Data Center Testing As the volume of fibers deployed into enterprise increases significantly, fiber cabling advances like multi-fiber (MPO) connectors and interfaces

More information

Structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling.

Structured (premises) wiring systems: building backbone (riser) and/or horizontal cabling. GIBT Breakout Cables Indoor I-V(ZN)HH 05-0- v6.0 Ordering Information Belden Part Numbers Fibre Description / count 4 6 8 4 6.5/5-OM GIBT0 GIBT04 GIBT06 GIBT08 GIBT GIBT4 50/5-OM BI GIBT0 GIBT04 GIBT06

More information

Lambda Tunnel A Pilot Optical Service Felix Kugler

Lambda Tunnel A Pilot Optical Service Felix Kugler Lambda Tunnel A Pilot Optical Service Felix Kugler 2005 SWITCH SWITCHlan Network 2005 1150 km of dark fiber deployed; 10 year leases from SBB and 20 year IRU from Fibre Lac Our standard

More information

Serial Storage Architecture. Fibre-Optic Extender 160 Application Guide

Serial Storage Architecture. Fibre-Optic Extender 160 Application Guide Fibre-Optic Extender 160 1.0 Overview The purpose of the Fibre-Optic Extender 160 product is to extend the range of a SSA 40MB/s serial link from 25m, which is the specified limit for a copper link, to

More information

Signature Core Fiber Optic Cabling System

Signature Core Fiber Optic Cabling System White Paper June 2012 WP-17 Signature Core Fiber Optic Cabling System Multimode Fiber: Understanding Chromatic Dispersion Introduction The performance and reliability of networks within the Data Center

More information

LEAD Fiber Optics PRODUCT CATALOGUE

LEAD Fiber Optics PRODUCT CATALOGUE LEAD Fiber Optics PRODUCT CATALOGUE FIBER OPTIC ATTENUATOR Fixed plug-in type TEL:+886-2-8672-2371 FAX:+886-2-8672-3275 Web:http://www.twfiberoptic.com Fixed plug in type Attenuator Fixed plug in fiber

More information

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2)

Plug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2) Plug & Play Universal Systems Harnesses have a pinned (male) MTP connector on one end that connects to a Plug & Play Universal Systems trunk or extender trunk, while the other end is equipped with single

More information

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration

W&T. Universal Fiber Optic Interface Converter W&T. Manual. Universal FO Interface Converter. Model Release 1.0. Subject to error and alteration Manual Universal FO Interface Converter Model 81215 Release 1.0 Subject to error and alteration 13 10/2012 by Wiesemann & Theis GmbH Subject to error and alteration: Since it is possible that we make mistakes,

More information

Strength member Waterblocked EGlass fibre elements Sheath 1.0 mm black FireBur sheath, UV stabilised, IEC Sheath marking Draka I/O CT LSHF 1.

Strength member Waterblocked EGlass fibre elements Sheath 1.0 mm black FireBur sheath, UV stabilised, IEC Sheath marking Draka I/O CT LSHF 1. 1000N central tube cable w 2 2 fibres, glass elements and black FireBur sheath, VDE UDQ(ZN)BH Application and installation This cable can be used for LAN and WAN backbones, telecom access lines, fibre

More information

BT Connect Networks that think Optical Connect UK

BT Connect Networks that think Optical Connect UK BT Connect Networks that think Optical Connect UK Fast, reliable, secure and affordable Connecting the heart of your organisation Your organisation and its people rely on its applications email, databases,

More information

SPECIFIC TERMS METRO ETHERNET SERVICE

SPECIFIC TERMS METRO ETHERNET SERVICE SPECIFIC TERMS METRO ETHERNET SERVICE This Specific Terms form the Agreement between you and SP Telecommunications Pte Ltd (Reg No. 199700517K) and may be amended by the Application Form. It is agreed

More information

Multimode Measurement Cords Recommendations for Multimode Link Field Certification

Multimode Measurement Cords Recommendations for Multimode Link Field Certification Multimode Measurement Cords Recommendations for Multimode Link Field Certification FiberXpert OTDR 1 BACKGROUND Different Multimode Cable Categories Multimode cables are at current categorised into 4 different

More information

Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 3

Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 3 Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 3 Reference Offer June 2017 1 Interpretation 1.1 References to clauses or sections are references to clauses or sections

More information

Optical Loss Budgets

Optical Loss Budgets CHAPTER 4 The optical loss budget is an important aspect in designing networks with the Cisco ONS 15540. The optical loss budget is the ultimate limiting factor in distances between nodes in a topology.

More information

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter

KI Channel Optical CWDM Power Meter. User Manual. KI6503 series 48-Channel Optical DWDM Power Meter User Manual KI6503 series 48-Channel Optical DWDM Power Meter Warranty: Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against

More information

VISIBLE FIBER OPTIC FAULT LOCATOR

VISIBLE FIBER OPTIC FAULT LOCATOR VISIBLE FIBER OPTIC FAULT LOCATOR Features: High visibility (up to 6 km with a 1 mw, 635 nm source) Higher output up to 30 mw, non-contact style power versions available Continuous light or pulse modulation

More information

Data Center & Cloud Computing Infrastruture Solutions DATASHEET. MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System

Data Center & Cloud Computing Infrastruture Solutions DATASHEET. MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System Data Center & Cloud Computing Infrastruture Solutions DATASHEET MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System REV.2.0 2018 MTP/MPO Breakout Cable 01 Description MTP/MPO breakout assemblies

More information

SUMITOMO SPECIFICATION. FutureFLEX. Multimode 62.5 µm Core Optical Fiber (OM1) Gigabit Grade

SUMITOMO SPECIFICATION. FutureFLEX. Multimode 62.5 µm Core Optical Fiber (OM1) Gigabit Grade SUMITOMO SPECIFICATION FutureFLEX Multimode 62.5 µm Core Optical Fiber (OM1) Gigabit Grade SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610 (919) 541-8100 or 1-800-358-7378

More information

Schedule 2a for Capital Leases

Schedule 2a for Capital Leases 1. SERVICE DESCRIPTION The Interoute Managed Bandwidth service comprises protected Circuits and unprotected Circuits carrying communications traffic between fixed points. 2. DEFINITIONS In this Agreement,

More information

REVISION HISTORY DATE AMENDMENT DESCRIPTION OF AMENDMENT

REVISION HISTORY DATE AMENDMENT DESCRIPTION OF AMENDMENT REVISION HISTORY DATE AMENDMENT DESCRIPTION OF AMENDMENT IFC SERVICE DESCRIPTION 17 OCTOBER 2016 Page 1 of 9 SERVICE DESCRIPTION 2-14: INTERNATIONAL FALCON CONNECTION SERVICE (IFC Service) 1. THE SERVICE

More information

Carrier Ethernet Service

Carrier Ethernet Service Issue date 15.02018 Replaces version 3-1 Valid from 002018 Agreement Contract for Data Services Contract for MLF Leased Lines Valid from 002018 1/10 Content 1 Introduction...3 2 General Service conditions...3

More information

Optical Time Domain Reflectometer USER'S GUIDE

Optical Time Domain Reflectometer USER'S GUIDE Optical Time Domain Reflectometer USER'S GUIDE AVOD EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION AVOD EYE OR SKIN EXPOSURE TO DIRECT OR SCATTERED RADIATION WARNING You are cautioned that changes

More information

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER

OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER / OPERATOR MANUAL OSD157 FIBER OPTIC RS422/RS232 MODEM/MULTIPLEXER PAGE 2 OF 17 INDEX 1 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND

More information

Retired. HP CWDM Slot B 4-port Add/Drop Multiplexer. HP CWDM 8-port Multiplexer HP CWDM Multiplexer 2-Slot Chassis

Retired. HP CWDM Slot B 4-port Add/Drop Multiplexer. HP CWDM 8-port Multiplexer HP CWDM Multiplexer 2-Slot Chassis QuickSpecs Overview The HP Coarse Wave Division Multiplexer (CWDM) solution Family is a set of passive optical systems designed to provide optical network support for high-speed data Fibre Channel & Ethernet

More information

Overview of WT&T LED light sources (fiber-coupled and free-space) WT&T Inc. Contact:

Overview of WT&T LED light sources (fiber-coupled and free-space) WT&T Inc. Contact: Overview of WT&T LED light sources (fiber-coupled and free-space) WT&T Inc. Contact: sales@wttechnology.com 2005-2015 WT&T Inc, all rights reserved Compact, high power, single channel fiber-coupled LED

More information

XFCxx070100D XFP CWDM Dual Fibre Transceiver ITU CWDM / 70km / 10 Gigabit Ethernet

XFCxx070100D XFP CWDM Dual Fibre Transceiver ITU CWDM / 70km / 10 Gigabit Ethernet XFCxx070100D XFP CWDM Dual Fibre Transceiver ITU CWDM / 70km / 10 Gigabit Ethernet For your product safety, please read the following information carefully before any manipulation of the transceiver: ESD

More information

AMENDED FINAL REPORT FOR:

AMENDED FINAL REPORT FOR: 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek.com AMENDED FINAL REPORT FOR: CUSTOMER NAME: Leviton Manufacturing Co. 417 Stone Drive St. Charles,

More information

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. Modular optical fibre telecontrol system. Application-ready systems from the

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. Modular optical fibre telecontrol system. Application-ready systems from the Application-ready systems from the MFW product family 29.11.2006 Modular optical fibre telecontrol system Optimised transmission speed variant MFW-GOLWL-BA-UK-000 INFOwww.ees-online.de Table of contents

More information

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities

OTS-600 Series Optical Sources, Meters, Testers and Kits with Data Storage Capabilities features and benefits Large LCD screen and soft key menus Source and meter in one unit Auto wavelength switching and detection USB data ports OTS-600 Series Light Source and Power Meter Photo LAN1193 Ease

More information

Network Service Assurance

Network Service Assurance Service Assurance Embedded 'Always-On' Ethernet Devices for Circuit 'Turn-Up' Testing & In-Service Assurance for Layer- 2 and Layer-3 infrastructures Ethernet (L-2) - Typical Scenario HQ & Operations Centre

More information

PROLITE-50/51/52 OPTICAL REFLECTOMETER (OTDR)

PROLITE-50/51/52 OPTICAL REFLECTOMETER (OTDR) PROLITE-50/51/52 OPTICAL REFLECTOMETER (OTDR) - 0 MI2119 - SAFETY NOTES Read the user s manual before using the equipment, mainly SAFETY RULES paragraph. The symbol on the equipment means SEE USER S MANUAL.

More information

Optimux-4T1 Four-Channel T1 Multiplexer

Optimux-4T1 Four-Channel T1 Multiplexer Data Sheet Optimux-4T1 Any Traffic Over Fiber Multiplexes four T1 channels over a fiber optics link with various fiber interfaces: multimode, single-mode (up to 120 km), and single-mode over single fiber

More information

AMENDED FINAL REPORT FOR:

AMENDED FINAL REPORT FOR: 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek.com AMENDED FINAL REPORT FOR: CUSTOMER NAME: PRODUCT NAME: Leviton Manufacturing Co. 417 Stone Drive

More information

LEAD Fiber Optics PRODUCT CATALOGUE

LEAD Fiber Optics PRODUCT CATALOGUE LEAD Fiber Optics PRODUCT CATALOGUE OPTICAL TERMINATOR TEL:+886-2-8672-2371 FAX:+886-2-8672-3275 Web:http:// Optical Terminator Optical Terminators are used to terminate unused fiber connector ports in

More information

Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 2

Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 2 Chorus UFB Services Agreement Bitstream Services: Service Description for Bitstream 2 Reference Offer June 2017 1 Interpretation 1.1 References to clauses or sections are references to clauses or sections

More information

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System

4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-022 2017A-0330 4 Channel 4~20mA/0~10VDC Analog Data Fiber Link System SYSTEM INSTALLATION INFORMATION Description The 4 Channel

More information

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM

OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OPERATOR MANUAL OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM OSD461A/OSD463A AUDIO FIBER OPTIC TRANSMISSION SYSTEM Document No. 101052 Rev. 01 PAGE 2 INDEX 1 1 TECHNICAL SUMMARY... 4 1.1 BRIEF

More information

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B

FL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide

More information

OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM

OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM OPERATOR MANUAL OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM OSD156 SYNCHRONOUS FIBER OPTIC RS232 MODEM Document No. 10104401 Page 2 of 14 INDEX 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION...4 1.1.1

More information

Fiber Optic and CAT 5-6 Installer Premise Cabling

Fiber Optic and CAT 5-6 Installer Premise Cabling Hands-On Fiber Optic and CAT 5-6 Installer Premise Cabling Certification Course Description This Hands-On course is customized to give Technicians the confidence and skills to maintain Fiber Optic systems

More information

Diamond FLQ-Series. Q-Switched Fiber Lasers FEATURES & BENEFITS

Diamond FLQ-Series. Q-Switched Fiber Lasers FEATURES & BENEFITS Series Q-Switched Fiber Lasers The Coherent Series is a 1 μm pulsed laser delivering 1 mj pulse energy with a fast turn-on time and high peak power (up to 10 kw) over a wide range of repetition rates to

More information

LAMPIRAN. Source type SLM SLM SLM Maximum spectral power mw/ ffs ffs ffs Ffs

LAMPIRAN. Source type SLM SLM SLM Maximum spectral power mw/ ffs ffs ffs Ffs LAMPIRAN Table 8-6/G.959.1 Single-channel IrDI parameters and values for optical tributary signal class NRZ 10G short-haul applications for G.652 fibre Parameter Units P1S1-2D1 P1S1-2D2a P1S1-2D2b 1S1-2D2bF

More information

Optimux-1553 STM-1/OC-3 Terminal Multiplexer

Optimux-1553 STM-1/OC-3 Terminal Multiplexer Data Sheet Optimux-1553 STM-1/OC-3 terminal multiplexer for grooming high order legacy traffic (TDM) over SDH/SONET networks Any Traffic Over Fiber Multiplexes up to three E3 or T3 data channels using

More information

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter

KI6501 Optical CWDM Power Meter. User Manual. KI6501 series Optical CWDM Power Meter User Manual KI6501 series Optical CWDM Power Meter Warranty: Information in this manual is given in good faith for the benefit of the user. It cannot be used as the basis for claims against Kingfisher

More information

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE

OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE OPERATOR MANUAL OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE OSD381 FIBER OPTIC CCTV TRANSMITTER MODULE Document No. 10100902 PAGE 1 INDEX 1 1 TECHNICAL SUMMARY... 3 1.1 BRIEF DESCRIPTION...3 1.1.1 OVERVIEW...

More information

VE883. 4K HDMI Optical Extender (K1, MM) / 10km (K2, SM))

VE883. 4K HDMI Optical Extender (K1, MM) / 10km (K2, SM)) VE883 4K HDMI Optical Extender (4K@300m (K1, MM) / 10km (K2, SM)) The VE883 is a fiber-based extender designed to extend uncompressed 4K signal up to 300 m (using VE883K1) or 10 km (using VE883K2) over

More information

ITU-T G.979. Characteristics of monitoring systems for optical submarine cable systems

ITU-T G.979. Characteristics of monitoring systems for optical submarine cable systems I n t e r n a t i o n a l T e l e c o m m u n i c a t i o n U n i o n ITU-T G.979 TELECOMMUNICATION STANDARDIZATION SECTOR OF ITU (11/2016) SERIES G: TRANSMISSION SYSTEMS AND MEDIA, DIGITAL SYSTEMS AND

More information

Data Center Applications and MRV Solutions

Data Center Applications and MRV Solutions Data Center Applications and MRV Solutions Introduction For more than 25 years MRV has supplied the optical transport needs of customers around the globe. Our solutions are powering access networks for

More information

VCL-TP, Teleprotection Equipment

VCL-TP, Teleprotection Equipment VCL-TP, Teleprotection Equipment Data Sheet Copyright: Valiant Communications Limited. - 2013 1 Product Overview VCL-TP, Teleprotection Equipment is an extremely reliable and flexible product that offers

More information

SIN 481 Issue 1.3 August 2016

SIN 481 Issue 1.3 August 2016 SIN 481 Issue 1.3 August 2016 Suppliers' Information Note For The BT Network Openreach Bulk Transport Link (BTL) Service & Interface Description Each SIN is the copyright of British Telecommunications

More information

AOR500-P PON Optical Time Domain Reflectometer USER'S GUIDE

AOR500-P PON Optical Time Domain Reflectometer USER'S GUIDE AOR500-P PON Optical Time Domain Reflectometer USER'S GUIDE WARNING You are cautioned that changes or modifications not espressly approved in this document could void yout authority to operate this equipment.

More information

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE

OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE OPERATOR MANUAL OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE OSD361 FIBER OPTIC CCTV TRANSMITTER MODULE Document No. 10102303 PAGE 1 INDEX 1 1 TECHNICAL SUMMARY... 3 1.1 BRIEF DESCRIPTION...3 1.1.1 OVERVIEW...

More information

SBU35020DRxx SFP Single Upstream Transceiver Tx 1310nm & Rx 1550nm / 20km / Dual Rate

SBU35020DRxx SFP Single Upstream Transceiver Tx 1310nm & Rx 1550nm / 20km / Dual Rate DATASHEET - REV A SBU35020DRxx SFP Single Upstream Transceiver Tx 1310nm & Rx 1550nm / 20km / Dual Rate #01 Overview SBU35020DRx0 is a high performance transceiver module for Gigabit Ethernet and Fast

More information

Wholesale Ethernet Interconnect Link (WEIL) with In-Span Handover (ISH), In-Building Handover (IBH) & Edge Node Handover (ENH) Product Description

Wholesale Ethernet Interconnect Link (WEIL) with In-Span Handover (ISH), In-Building Handover (IBH) & Edge Node Handover (ENH) Product Description Wholesale Ethernet Interconnect Link (WEIL) with In-Span Handover (ISH), In-Building Handover (IBH) & Edge Node Handover (ENH) Product Description Issue 1.3 Effective from 20/1/2012 Revision history Version

More information

1 of 5 12/31/2008 8:41 AM

1 of 5 12/31/2008 8:41 AM 1 of 5 12/31/2008 8:41 AM SAVE THIS EMAIL THIS Close All multimode fiber is not created equal By Robert Reid Bandwidth, reach, and cost are among the key factors you ll need to weigh. Multimode fiber cabling

More information

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd

V C ALIANT OMMUNICATIONS. VCL-4 E1 + Ethernet PDH Optical Multiplexer. Data Sheet U.K. INDIA U.S.A. Valiant Communications (UK) Ltd V C ALIANT OMMUNICATIONS VCL-4 E1 + Ethernet PDH Optical Multiplexer Data Sheet U.K. Valiant Communications (UK) Ltd Central House Rear Office 124 High Street, Hampton Hill Middlesex, TW12 1NS, U.K. E-mail:

More information

Service Definition Wavelength Service

Service Definition Wavelength Service Service Definition Wavelength Service Standard S003 Ver 2 Contents 1 Overview... 1 1.1 Introduction... 1 1.2 Product Overview... 1 2 Service Specification... 1 3 Service Levels... 2 3.1 Target Service

More information

4 Channel Contact Closure DIN Fiber Link System

4 Channel Contact Closure DIN Fiber Link System USER GUIDE RLH Industries, Inc. The leader in rugged fiber optic technology. U-027 2017A-0420 4 Channel Contact Closure DIN Fiber Link System SYSTEM INSTALLATI INFORMATI Description The 4 Channel Contact

More information

CinCam CCD - Technical Data -

CinCam CCD - Technical Data - - Technical Data - SENSOR DATA CCD-1201 CCD-1301 CCD-2301 CCD-2302 Format: 1/2 1/3 2/3 2/3 Active area: 6.5mm x 4.8mm 4.8mm x 3.6mm 9.0mm x 6.7mm 8.5mm x 7.1mm Number of pixel: 1388 x 1038 (1.4MPixel)

More information

TOM103. Optical Power Meter OPTICAL POWER METER

TOM103. Optical Power Meter OPTICAL POWER METER OPTICAL POWER METER TOM103 Optical Power Meter Wave ID - Auto wavelength identification & switching Frequency ID - Auto frequency identification Self-calibration function Reference power level can be set

More information

MT-7610 Optical Time Domain Reflectometer USER'S GUIDE

MT-7610 Optical Time Domain Reflectometer USER'S GUIDE MT-7610 Optical Time Domain Reflectometer USER'S GUIDE English Test Equipment Depot - 800.517.8431-99 Washington Street - Melrose, MA 02176 TestEquipmentDepot.com AVOD EYE OR SKIN EXPOSURE TO DIRECT OR

More information

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No

SIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No SIMADYN D Digital Control System User Manual Fiber-Optic Rack Coupling CS12 Edition 05.95 DK No. 237741 User Manual, Fiber-Optic Rack Coupling CS12 Edition Status 1 Fiber-Optic Rack Coupling CS12 05.95

More information

Data Center & Cloud Computing DATASHEET. FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions

Data Center & Cloud Computing DATASHEET. FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions Data Center & Cloud Computing DATASHEET FS.COM WDM Transport Networks Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 01 Overview About the Features Efficient Usage Supports up 18 to

More information

SIN 508 Issue 1.2 August 2016

SIN 508 Issue 1.2 August 2016 SIN 508 Issue 1.2 August 2016 Suppliers' Information Note For The BT Network OPENREACH TIME DIVISION MULTIPLEX ACCESS BEARER SERVICES (TDM ACCESS) Service Description Each SIN is the copyright of British

More information

Maintenance and Troubleshooting of a PON Network with an OTDR

Maintenance and Troubleshooting of a PON Network with an OTDR Application Note VIAVI Solutions Maintenance and Troubleshooting of a PON Network with an Troubleshooting a faulty passive optical point-to-multipoint network (PON) can be more complex than a point-to-point

More information

Multicom 1550nm High Power Erbium Doped Fiber Amplifier MUL 2RU EDFA 1550 XX xx

Multicom 1550nm High Power Erbium Doped Fiber Amplifier MUL 2RU EDFA 1550 XX xx Multicom 1550nm High Power Erbium Doped Fiber Amplifier User Manual v.2 www.multicominc.com 800 423 2594 407 331 7779 1076 Florida Central Parkway, Longwood, FL 32750 SAFETY NOTIFICATION The Multicom MUL

More information

Elisa Carrier Services. Elisa Operator Broadband Services. Technologies, distribution centres and delivery interfaces

Elisa Carrier Services. Elisa Operator Broadband Services. Technologies, distribution centres and delivery interfaces 1(6) Elisa Operator Broadband Services Elisa Operator Broadband Services comprise wholesalelevel bitstream data subscriptions classified as broadband services by the Finnish Communications Regulatory Authority

More information

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 40 Channels C21-C60 Dual Fiber DWDM Mux Demux + Monitor Port. 1U Rack Mount, LC/UPC

DATASHEET. Data Center & Cloud Computing Infrastruture Solutions. 40 Channels C21-C60 Dual Fiber DWDM Mux Demux + Monitor Port. 1U Rack Mount, LC/UPC Data Center & Cloud Computing DATASHEET 40 Channels C21-C60 Dual Fiber DWDM Mux Demux + Monitor Port 1U Rack Mount, LC/UPC Data Center & Cloud Computing Infrastruture Solutions REV.1.0 2018 Overview DWDM

More information

Chorus UFB Services Agreement Service Description for Bitstream 2

Chorus UFB Services Agreement Service Description for Bitstream 2 Chorus UFB Services Agreement Service Description for Bitstream 2 1 Interpretation 1.1 The Bitstream 2 Service described in this Service Description will be available from the date it is launched by the

More information

MTP/MPO Cable Assemblies

MTP/MPO Cable Assemblies MTP/MPO Cable Assemblies MTP cable assemblies are multi-fiber patch cords suitable for high-density back plane and PCB solutions. MTP brand Fan-Out, Interconnect and Trunk cable offer up to 36 times the

More information

We protect IT DC-MONITORING. When more surveillance leads to added value. Member of the DATA CENTER GROUP

We protect IT DC-MONITORING. When more surveillance leads to added value. Member of the DATA CENTER GROUP We protect IT DC-MONITORING When more surveillance leads to added value Member of the DATA CENTER GROUP DC-MonIToring How more surveillance leads to added value What is your data center doing right now?

More information

SFCxx100PAxD SFP Dual fibre CWDM ITU CWDM / 100km / OC-48 Multirate.

SFCxx100PAxD SFP Dual fibre CWDM ITU CWDM / 100km / OC-48 Multirate. SFCxx100PAxD_RevA SFCxx100PAxD SFP Dual fibre CWDM ITU CWDM / 100km / OC-48 Multirate. For your product safety, please read the following information carefully before any manipulation of the transceiver:

More information

Nicotra Sistemi RTU 2012 REMOTE TEST UNIT KEY FEATURES

Nicotra Sistemi RTU 2012 REMOTE TEST UNIT KEY FEATURES RTU 2012 REMOTE TEST UNIT KEY FEATURES 1 * Developed for long haul and FTTx point-to-point network * Small size (3U) * Low power consumption * Improved OTDR performances * Improved fast fiber scan mode

More information

AMENDED FINAL REPORT FOR:

AMENDED FINAL REPORT FOR: 731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com AMENDED FINAL REPORT FOR: CUSTOMER NAME: PRODUCT NAME: Leviton 2222 222nd St. SE Bothell,

More information

Basic Fiber Optic Concepts

Basic Fiber Optic Concepts Basic Fiber Optic Concepts Advantages of Fiber Optics A signal can be sent over long distances (200 Km/125 miles) without the need for regeneration Not sensitive to electromagnetic or radio frequency

More information

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM

OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM OPERATOR MANUAL OSD139A ASYNCHRONOUS FIBER OPTIC RS232 MODEM Page 2 of 16 INDEX 1. TECHNICAL SUMMARY... 4 1.1 BRIEF DESCRIPTION... 4 1.1.1 OVERVIEW... 4 1.1.2 APPLICATIONS... 4 1.1.3 FEATURES AND BENEFITS...

More information

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet.

FL SWITCH Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings. Data sheet. Factoryline 5- and 8-port managed switches with optional fiber optic ports and wide temperature ratings Data sheet 3037_en_B PHOENIX CONTACT 2012-06-20 1 Description The FL SWITCH 300 managed switches

More information

WaveReady Eight-Port Any Service OTN Muxponder WRM-8008T000B

WaveReady Eight-Port Any Service OTN Muxponder WRM-8008T000B WaveReady Eight-Port Any Service OTN Muxponder WRM-8008T000B www.lumentum.com Data Sheet A flexible WDM transport solution The WRM-8008 is a next-generation OTN muxponder that can transparently aggregate

More information

MTP Multi Lite Trunk Assemblies

MTP Multi Lite Trunk Assemblies MTP Multi Lite Trunk Assemblies MTP Multi-Lite Trunk assemblies are a neat solution for providing up to four MTP -MTP links within a compact, high density ruggedised cable. The cable construction consists

More information

QFPQL010400D QSFP+ Dual Fibre CWDM ITU CWDM / 10km / 40 Gigabit Ethernet / LR-4

QFPQL010400D QSFP+ Dual Fibre CWDM ITU CWDM / 10km / 40 Gigabit Ethernet / LR-4 DATASHEET - REV A QFPQL010400D QSFP+ Dual Fibre CWDM ITU CWDM / 10km / 40 Gigabit Ethernet / LR-4 #01 Overview QFPQL010400D is a high performance QSFP+ transceiver module for 40 Gigabit Ethernet data links

More information

Advanced Fiber Optic Connector Installation

Advanced Fiber Optic Connector Installation Advanced Fiber Optic Connector Installation QUICK SUMMARY Length: 48 hours, 52 hours with Fiber Optic Association CFOT certification Hands-on Activities: activities, 70-75 % Text/Field Reference: Professional

More information

Cisco MDS 9000 Family Pluggable Transceivers

Cisco MDS 9000 Family Pluggable Transceivers Cisco MDS 9000 Family Pluggable Transceivers The Cisco Small Form-Factor Pluggable (), and X2 devices for use on the Cisco MDS 9000 Family are hot-swappable transceivers that plug into ports on the Cisco

More information