AMENDED FINAL REPORT FOR:
|
|
- Mildred Lester
- 6 years ago
- Views:
Transcription
1 731 Enterprise Drive Lexington, KY Telephone: Facsimile: AMENDED FINAL REPORT FOR: CUSTOMER NAME: Leviton Manufacturing Co. 417 Stone Drive St. Charles, IL PRODUCT NAME: 24 Fiber 40G OM3 Link System and 24 Fiber 40G OM4 Link System Tested To: IEEE 802.3ba-2010 IEEE Standard for Information technology-- Local and metropolitan area networks-- Specific requirements-- Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment 4: Media Access Control Parameters, Physical Layers, and Management Parameters for 40 Gb/s and 100 Gb/s Operation, June 2010 Date: September 28, 2011 Project: G Report: LEX Responsible Engineer: Date: 9/28/2011 Paul Alt, Senior Project Engineer Approved By: Date: 9/28/2011 Richard Proctor, Operations Manager This report is for the exclusive use of Intertek's Client and is provided pursuant to the agreement between Intertek and its Client. Intertek's responsibility and liability are limited to the terms and conditions of the agreement. Intertek assumes no liability to any party, other than to the Client in accordance with the agreement, for any loss, expense or damage occasioned by the use of this report. Only the Client is authorized to copy or distribute this report and then only in its entirety. Any use of the Intertek name or one of its marks for the sale or advertisement of the tested material, product or service must first be approved in writing by Intertek. The observations and test results in this report are relevant only to the sample tested. This report by itself does not imply that the material, product, or service is or has ever been under an Intertek certification program. Intertek Testing Services NA, Inc.
2 TABLE OF CONTENTS Page Declaration of Compliance...3 Sample Condition and Receive Date IEEE 802.3ba-2010, IEEE Standard for Information technology-- Local and metropolitan area networks-- Specific requirements Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment 4: Media Access Control Parameters, Physical Layers, and Management Parameters for 40 Gb/s and 100 Gb/s Operation...4 References:...16 LIST OF TABLES Page Table 1: History of Revision...2 Table 2: IEEE 802.3ba Amendment 4: Media Access Control Parameters, Physical Layers, and Management Parameters for 40 Gb/s and 100 Gb/s Operation - Table Fiber Optic Cabling Channel Characteristics at 850 nm - Table Fiber Optic Cabling Channel Characteristics at 850 nm...4 Table 3: 24 Fiber 40G OM3 Link System Part Numbers and Quantities...6 Table 4: 24 Fiber 40G OM4 Link System Part Numbers and Quantities...7 Table 5: Insertion Loss Forward Reading at 850 nm...9 Table 6: Insertion Loss Reverse Reading at 850 nm...10 Table 7: Insertion Loss Average Reading at 850 nm...11 Table 8: Insertion Loss Forward Reading at 850 nm...12 Table 9: Insertion Loss Reverse Reading at 850 nm...13 Table 10: Insertion Loss Average Reading at 850 nm...14 LIST OF FIGURES Page Figure 1: Cable Link Channel Testing Configuration...6 Figure 2: Manufacturer s 24 Fiber 40G OM3 Link System Diagram...6 Figure 3: 24 Fiber 40G OM3 Link System Test Setup...15 Figure 4: 24 Fiber 40G OM4 Link System Test Setup...15 Table 1: History of Revision Revision Date Section # Description of Revision Original August 30, 2011 All Original Document Issued 01 September 8, 2011 All Corrected reference to IEEE standard 02 September 28, 2011 Pages 12,13 & 14 Data Correction in Tables Report: LEX Page 2 of 16 Revision 02
3 Declaration of Compliance The 24 Fiber 40G OM3 Link System and 24 Fiber 40G OM4 Link System were evaluated and found to be compliant with all applicable criteria of channel insertion loss testing for IEEE 802.3ba-2010, IEEE Standard for Information technology-- Local and metropolitan area networks-- Specific requirements-- Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment 4: Media Access Control Parameters, Physical Layers, and Management Parameters for 40 Gb/s and 100 Gb/s Operation, June Sample Condition and Receive Date Leviton Manufacturing Co. selected and provided the test samples for evaluation to the criteria of IEEE 802.3ba-2010, IEEE Standard for Information technology-- Local and metropolitan area networks-- Specific requirements-- Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment 4: Media Access Control Parameters, Physical Layers, and Management Parameters for 40 Gb/s and 100 Gb/s Operation, June The equipment tested was the 24 Fiber 40G OM3 Link System and 24 Fiber 40G OM4 Link System; the new and unused samples were tested by Leviton and witnessed by Intertek on 8/15/2011. Report: LEX Page 3 of 16 Revision 02
4 1 IEEE 802.3ba-2010, IEEE Standard for Information technology-- Local and metropolitan area networks-- Specific requirements 1.1 Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment 4: Media Access Control Parameters, Physical Layers, and Management Parameters for 40 Gb/s and 100 Gb/s Operation Channel Insertion Loss Testing Conformance Criteria The cable link system channel shall not exhibit a change greater than the value stated in Table 2 below for the Multi-Mode test condition and the corresponding product type evaluation. a. For this evaluation, the criteria is for an Ethernet 40GBASE-SR4 and 100GBASE- SX system measured at 850 nm laser-optimized 50/125 µm TIA 492AAAC (OM3) having a maximum channel value of 1.9 db as indicated by the matching values in Table 2. b. For this evaluation, the criteria is for an Ethernet 40GBASE-SR4 and 100GBASE- SX system measured at 850 nm laser-optimized 50/125 µm TIA 492AAAD (OM4) having a maximum channel value of 1.5 db as indicated by the matching values in Table 2. Table 2: IEEE 802.3ba Amendment 4: Media Access Control Parameters, Physical Layers, and Management Parameters for 40 Gb/s and 100 Gb/s Operation - Table Fiber Optic Cabling Channel Characteristics at 850 nm - Table Fiber Optic Cabling Channel Characteristics at 850 nm. Description Type OM3 OM4 Unit Operating Distance Max m Cabling Skew a Max 79 ns Cabling Skew Variation Max 2.5 ns Channel Insertion Loss Min 0 db Channel Insertion Loss b Max 1.9 c 1.5 d db a An additional 300 ps of Skew Variation could be caused by wavelength changes, which are attributable to the transmitter, not the channel. b These channel insertion loss values include cable, connectors and splices. c 1.5 db allocated for connection and splice loss. d 1 db allocated for connection and splice loss. Report: LEX Page 4 of 16 Revision 02
5 Sample Size One 24 Fiber 40G OM3 Link System and one 24 Fiber 40G OM4 Link System were tested for compliance to IEEE 802.3ba-2010, IEEE Standard for Information technology-- Local and metropolitan area networks-- Specific requirements-- Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment 4: Media Access Control Parameters, Physical Layers, and Management Parameters for 40 Gb/s and 100 Gb/s Operation Test Method 1. The test methodology used was the Leviton Manufacturing Co. internal qualification document FBFMM127, Revision A, dated 2/23/2011 titled Insertion Loss and Continuity Testing Instructions on the 24 Channel MM OptoTest Power Meter. 2. These instructions were reviewed prior to the start of testing and found to be sufficient to the required channel loss testing as detailed in IEEE 802.3ba-2010, IEEE Standard for Information technology-- Local and metropolitan area networks- - Specific requirements-- Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment 4: Media Access Control Parameters, Physical Layers, and Management Parameters for 40 Gb/s and 100 Gb/s Operation, June Prior to the beginning of testing, the Intertek witness representative reviewed the training records of all employees involved to determine that the manufacturer had kept detailed training records of testing qualifications. 4. The testing was conducted per the FBFMM127, Revision A, dated 2/23/2011 titled Insertion Loss and Continuity Testing Instructions on the 24 Channel MM OptoTest Power Meter and the results were recorded. 5. The data was reviewed by the Intertek witness representative and found to be compliant with all applicable criteria. 6. The loss for each channel, as well as the measurement direction the loss was calculated in, was reported individually in the Test Results section of this report Test Configurations and Conditions The test was conducted at lab ambient atmospheric conditions; 23 2 C, ~75% RH. Optical measurements were taken at 850 nm. The test measurement configuration is demonstrated in Figure 1. The customer s OM3 equipment configuration is demonstrated in Figure 2 and the individual part identification numbers are listed in Table 3. The customer s OM4 equipment configuration is demonstrated in Figure 2 and the individual part identification numbers are listed in Table 4. Report: LEX Page 5 of 16 Revision 02
6 Figure 1: Cable Link Channel Testing Configuration Figure 2: Manufacturer s 24 Fiber 40G OM3 Link System Diagram Table 3: 24 Fiber 40G OM3 Link System Part Numbers and Quantities Item Leviton Part Number Description Qty 1 FH-EH024HG336BC Harness, 24 fiber-mtp to FC/APC, 3FT, OM3 1 2 FH-EH024HM312BE Array Harness, 24 fiber,mtp to 3x8 fiber MTP, OM3, Method B, Edge, 5Meter 2 3 FH-EH024HM312BC Array Harness, 24 fiber, MTP to 3x8 fiber MTP, OM3, Method B, Core, 5Meter 1 4 FT-EB024JJ100M36C36CN-NNBS Trunk, 24 fiber, OM3, MTP-MTP, Plenum, Method B, 100M 1 5 5F100-MB MTP Adapter plate 4 Report: LEX Page 6 of 16 Revision 02
7 Table 4: 24 Fiber 40G OM4 Link System Part Numbers and Quantities Item Leviton Part Number Description Qty 1 FH-FH024HG336BC Harness, 24 fiber-mtp to FC/APC, 3FT, OM4 1 2 FH-FH024HM312BE Array Harness, 24 fiber, MTP to 3x8 fiber MTP, OM4, Method B, Edge, 5Meter 2 3 FH-FH024HM312BC Array Harness, 24 fiber, MTP to 3x8 fiber MTP, OM4, Method B, Core, 5Meter 1 4 FT-EB024JJ150M36C36CN-NNBS Trunk, 24 fiber, OM4, MTP-MTP, Plenum, Method B, 150M 1 5 5F100-MB MTP Adapter plate Test Equipment Channel Insertion Loss Testing Equipment Type Manufacturer Model Last Cal Next Cal Number Date Date Fiber Optic Cleaning Reels CLETOP Type A NA NA 850 nm Light Source OptoTest OP930-MM- SW24-85/13 NA NA Power Meter with S-RHIS Detector Head OptoTest OP710-R-S 11/30/ /30/2011 Optical Fiber Multi Mode 50/125 µm Jacketed Cable (Launch Lead) Leviton NA NA NA Mandrel Wrap Leviton NA NA NA Computer with Measurement Software Leviton NA NA NA NA: Not Applicable Report: LEX Page 7 of 16 Revision 02
8 Summary of Test Results Conformance/Nonconformance Criteria Ethernet 40GBASE-SR4 and 100GBASE-SX system measured at 850 nm laser-optimized 50/125 µm TIA 492AAAC (OM3) having a maximum channel value of 1.9 db Ethernet 40GBASE-SR4 and 100GBASE-SX system measured at 850 nm laser-optimized 50/125 µm TIA 492AAAD (OM4) having a maximum channel value of 1.5 db as indicated by the matching values in Table 2. Conforms? C/NC C C Actual Sample Size and Test Method Deviations One 24 Fiber 40G OM3 Link System and one 24 Fiber 40G OM4 Link System were tested for compliance to this section. There were no deviations from, additions to, or exclusions from, the documented test method here. Failure History There was no history of failure for the testing in this section. Disposition of Nonconformance There was no failure for the testing in this section. Report: LEX Page 8 of 16 Revision 02
9 Test Data OM3 Channel Table 5: Insertion Loss Forward Reading at 850 nm Test Witnessed By: Test Date Paul Alt 8/15/2011 OM3 Configuration Directional Reading Max Value (db) Loss Criteria Complies? Y/N 1 Forward db Y 2 Forward db Y 3 Forward db Y 4 Forward db Y 5 Forward db Y 6 Forward db Y 7 Forward db Y 8 Forward db Y 9 Forward db Y 10 Forward db Y 11 Forward db Y Fiber 40G OM3 Link Forward db Y 13 System Forward db Y 14 Forward db Y 15 Forward db Y 16 Forward db Y 17 Forward db Y 18 Forward db Y 19 Forward db Y 20 Forward db Y 21 Forward db Y 22 Forward db Y 23 Forward db Y 24 Forward db Y Report: LEX Page 9 of 16 Revision 02
10 OM3 Channel Table 6: Insertion Loss Reverse Reading at 850 nm Test Witnessed By: Test Date Paul Alt 8/15/2011 OM3 Configuration Directional Reading Max Value (db) Loss Criteria Complies? Y/N 1 Reverse db Y 2 Reverse db Y 3 Reverse db Y 4 Reverse db Y 5 Reverse db Y 6 Reverse db Y 7 Reverse db Y 8 Reverse db Y 9 Reverse db Y 10 Reverse db Y 11 Reverse db Y Fiber 40G OM3 Link Reverse db Y 13 System Reverse db Y 14 Reverse db Y 15 Reverse db Y 16 Reverse db Y 17 Reverse db Y 18 Reverse db Y 19 Reverse db Y 20 Reverse db Y 21 Reverse db Y 22 Reverse db Y 23 Reverse db Y 24 Reverse db Y Report: LEX Page 10 of 16 Revision 02
11 OM3 Channel Table 7: Insertion Loss Average Reading at 850 nm Test Witnessed By: Test Date Paul Alt 8/15/2011 OM3 Configuration Directional Reading Max Value (db) Loss Criteria Complies? Y/N 1 Average db Y 2 Average db Y 3 Average db Y 4 Average db Y 5 Average db Y 6 Average db Y 7 Average db Y 8 Average db Y 9 Average db Y 10 Average db Y 11 Average db Y Fiber 40G OM3 Link Average db Y 13 System Average db Y 14 Average db Y 15 Average db Y 16 Average db Y 17 Average db Y 18 Average db Y 19 Average db Y 20 Average db Y 21 Average db Y 22 Average db Y 23 Average db Y 24 Average db Y Report: LEX Page 11 of 16 Revision 02
12 OM4 Channel Table 8: Insertion Loss Forward Reading at 850 nm Test Witnessed By: Test Date Paul Alt 8/15/2011 OM4 Configuration Directional Reading Max Value (db) Loss Criteria Complies? Y/N 1 Forward db Y 2 Forward db Y 3 Forward db Y 4 Forward db Y 5 Forward db Y 6 Forward db Y 7 Forward db Y 8 Forward db Y 9 Forward db Y 10 Forward db Y 11 Forward db Y Fiber 40G OM4 Link Forward db Y 13 System Forward db Y 14 Forward db Y 15 Forward db Y 16 Forward db Y 17 Forward db Y 18 Forward db Y 19 Forward db Y 20 Forward db Y 21 Forward db Y 22 Forward db Y 23 Forward db Y 24 Forward db Y Report: LEX Page 12 of 16 Revision 02
13 OM4 Channel Table 9: Insertion Loss Reverse Reading at 850 nm Test Witnessed By: Test Date Paul Alt 8/15/2011 OM4 Configuration Directional Reading Max Value (db) Loss Criteria Complies? Y/N 1 Reverse db Y 2 Reverse db Y 3 Reverse db Y 4 Reverse db Y 5 Reverse db Y 6 Reverse db Y 7 Reverse db Y 8 Reverse db Y 9 Reverse db Y 10 Reverse db Y 11 Reverse db Y Fiber 40G OM4 Link Reverse db Y 13 System Reverse db Y 14 Reverse db Y 15 Reverse db Y 16 Reverse db Y 17 Reverse db Y 18 Reverse db Y 19 Reverse db Y 20 Reverse db Y 21 Reverse db Y 22 Reverse db Y 23 Reverse db Y 24 Reverse db Y Report: LEX Page 13 of 16 Revision 02
14 OM4 Channel Table 10: Insertion Loss Average Reading at 850 nm Test Witnessed By: Test Date Paul Alt 8/15/2011 OM4 Configuration Directional Reading Max Value (db) Loss Criteria Complies? Y/N 1 Average db Y 2 Average db Y 3 Average db Y 4 Average db Y 5 Average db Y 6 Average db Y 7 Average db Y 8 Average db Y 9 Average db Y 10 Average db Y 11 Average db Y Fiber 40G OM4 Link Average db Y 13 System Average db Y 14 Average db Y 15 Average db Y 16 Average db Y 17 Average db Y 18 Average db Y 19 Average db Y 20 Average db Y 21 Average db Y 22 Average db Y 23 Average db Y 24 Average db Y Report: LEX Page 14 of 16 Revision 02
15 Photographs: Figure 3: 24 Fiber 40G OM3 Link System Test Setup Figure 4: 24 Fiber 40G OM4 Link System Test Setup Report: LEX Page 15 of 16 Revision 02
16 References: External Reference Documents ANSI Z136.2 ANS For Safe Use Of Optical Fiber Communication Systems Utilizing Laser Diode And LED Sources ANSI/TIA-568-C.0 General Telecommunications Cabling for Customer Premises ANSI/TIA-568-C.1 Commercial Building Telecommunications Cabling Standard ANSI/TIA-568-C.2 Balanced Twisted-Pair Telecommunications Cabling and Components Standard ANSI/TIA Fiber Optic Connector Intermateability Standard, Type SC and SC- APC ANSI/TIA Fiber optic Intermateability Standard, Type MPO IEEE C2-2007, National Electrical Safety Code (NESC ) IEEE , Carrier Sense Multiple Access with Collision Detection (CSMA/CD) Access Method and Physical Layer Specifications IEEE 802.3ba-2010, IEEE Standard for Information technology-- Local and metropolitan area networks-- Specific requirements-- Part 3: CSMA/CD Access Method and Physical Layer Specifications Amendment 4: Media Access Control Parameters, Physical Layers, and Management Parameters for 40 Gb/s and 100 Gb/s Operation IEC , Industrial Communication Networks - Installation of Communication Networks in Industrial Premises NFPA 70, National Electrical Code TIA-492AAAA, Detail Specification For 62.5-μm Core Diameter/125-μm Cladding Diameter Class IA Graded-Index Multimode Optical Fibers TIA-492AAAB, Detail Specification For 50-μm Core Diameter/125-μm Cladding Diameter Class IA Graded-Index Multimode Optical Fibers TIA-492AAAC, Detail Specification For 850-nm Laser-Optimized, 50-μm Core Diameter/125-μm Cladding Diameter Class IA Graded-Index Multimode Optical Fibers TIA-492AAAD, Detail Specification For 850-nm Laser-Optimized, 50 µm Core Diameter/125 µm Cladding Diameter Class IA Graded-Index Multimode Optical Fibers of OM4 Performance TIA-492CAAA, Detail Specification For Class IVA Dispersion-Unshifted Single-Mode Optical Fibers TIA-492CAAB, Detail Specification For Class IVA Dispersion-Unshifted Single-Mode Optical Fibers With Low Water Peak TIA TSB-31-C, Telephone Terminal Equipment Rationale and Measurement Guidelines for US Network Protection 51 Report: LEX Page 16 of 16 Revision 02
AMENDED FINAL REPORT FOR:
731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek.com AMENDED FINAL REPORT FOR: CUSTOMER NAME: PRODUCT NAME: Leviton Manufacturing Co. 417 Stone Drive
More informationAMENDED FINAL REPORT FOR:
731 Enterprise Drive Lexington, KY 40510 Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com AMENDED FINAL REPORT FOR: CUSTOMER NAME: PRODUCT NAME: Leviton 2222 222nd St. SE Bothell,
More informationOpt-X Enterprise Fiber Trunk Cables
APPLICATION Factory-terminated and tested fiber trunk cables connect central patching locations to zones or pods. Available terminated with both modular (MTP ) and discrete connectors, these trunks are
More informationPretium EDGE Solutions Trunk Cable, 50 µm multimode (OM3)
Pretium EDGE 133 Pretium EDGE Solutions Trunk Cable, 50 Pretium EDGE Solutions trunk cables utilize the MTP Connector, a 12 -fiber push/pull optical connector with a footprint similar to the SC simplex
More informationInstalling Avaya P550 /P580/P880/P882
Installing Avaya P550 /P580/P880/P882 CHAPTER 1 Gigabit Ethernet Modules Overview This document describes the following processes: Gigabit-Speed Modules Compliance Information Software Requirements Power
More informationAdrian Young Leviton Network Solutions
Adrian Young Leviton Network Solutions In This Session Multimode fiber types How many fibers do I need for my application? Future IEEE and non IEEE applications Will my existing fiber plant support these?
More informationTest report number CRT-001 Project number CRT-001
3933 U Route 11 Cortland, NY 1345 Telephone: (7) 753-6711 Facsimile: (7) 758-59 www.intertek.com January 6, 2 L-Com Inc 45 Beechwood Drive L-Com Global Connectivity North Andover, MA 1845 Test report number
More informationOptical Fiber for Today s Premises Applications
Optical Fiber for Today s Premises Applications Tony Irujo Customer Technical Support Mgr. OFS Optical Fiber Division 508-347-8582 tirujo@ofsoptics.com 1 Copyright 2006 Fitel USA Corp., All rights reserved.
More informationIndustry Standards Activity Overview
Industry Standards Activity Overview Most Recent Plenary Meeting: June 12-16, 2017 in Quebec City, QC, CAN Updated: July 7, 2017 TR-42.1 Commercial Building Cabling: TIA TSB-185 Environmental Classification
More informationPlug & Play Universal Trunks
1 1 22.88 115 0 Plug & Play 0 Plug & Play Universal Trunks Plug & Play Universal Systems MTP Trunks provide the backbone of the Plug & Play System. With non - pinned MTPs on both ends of the cable, these
More informationIEEE Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3
IEEE 802.3 Ethernet Working Group TIA TR-42 Liaison to IEEE 802.3 Valerie Maguire The Siemon Company Dallas, TX November 9, 2015 Page 1 Introduction to TIA Telecommunications Industry Association www.tiaonline.org
More informationPretium EDGE Solutions Trunk Cable, OM4, Low-Loss, MTP to MTP, 24 fibres
Corning Cable 143 Pretium EDGE Solutions Trunk Cable, OM4, Corning Cable Systems LANscape Pretium EDGE (Evolved -Density, Growth -Enabled) Solutions are high density pre -terminated optical cabling systems
More informationSECTION COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING
SECTION 27 13 23 COMMUNICATIONS OPTICAL FIBER BACKBONE CABLING PART 1 GENERAL 1.01 DESCRIPTION A. The work covered by this section of the Specifications includes all labor necessary to perform and complete
More informationCopper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only
1 Copper Cabling from 10G to 400G, and back down to 10Mbps, but on 1 pair only Gautier Humbert, RCDD Standards Coordinator Digital Infrastructures Legrand District Chair Mainland Europe BICSI 2 Agenda
More informationMTP/MPO Cable Assemblies
MTP/MPO Cable Assemblies MTP cable assemblies are multi-fiber patch cords suitable for high-density back plane and PCB solutions. MTP brand Fan-Out, Interconnect and Trunk cable offer up to 36 times the
More informationPretium EDGE HD Solutions A LANscape Pretium Solutions Product
Pretium EDGE HD Solutions for Enterprise Data Centers and Storage Area Networks Corning Pretium EDGE HD solutions create a fiber optic tip-to-tip solution for data centers and storage area networks (SANs)
More informationPlug & Play Universal Harness, SMF-28 Ultra Single-mode (OS2)
Plug & Play Universal Systems Harnesses have a pinned (male) MTP connector on one end that connects to a Plug & Play Universal Systems trunk or extender trunk, while the other end is equipped with single
More informationInsuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions. Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions
Insuring 40/100G Performance Multimode Fiber Bandwidth Testing & Array Solutions Kevin Paschal Sr. Product Manager Enterprise Fiber Solutions Fiber Optics LAN Section Part of the Telecommunications Industry
More informationLeaders in the Advancement of Multimode Fiber. Fiber Future and Beyond
Leaders in the Advancement of Multimode Fiber Fiber Future and Beyond Major Milestones in the Advancement of Multimode Fiber (MMF) Transmission OM4 Signature Core Fiber Cabling TIA WBMMF ISO/IEC OM5 (WBMMF)
More informationCisco 10GBASE SFP+ Modules
Cisco 10GBASE SFP+ Modules Product Overview The Cisco 10GBASE SFP+ modules (Figure 1) offer customers a wide variety of 10 Gigabit Ethernet connectivity options for data center, enterprise wiring closet,
More informationAnixter Standards Reference Guide
Anixter: The Cabling System Experts Anixter is a leading global supplier of communications and security products, electrical and electronic wire and cable, fasteners and other small components. We help
More informationData Center & Cloud Computing Infrastruture Solutions DATASHEET. MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System
Data Center & Cloud Computing Infrastruture Solutions DATASHEET MTP/MPO-LC Breakout Cable Aseemblies High Density Cabling System REV.2.0 2018 MTP/MPO Breakout Cable 01 Description MTP/MPO breakout assemblies
More informationMTP Cabling Overview. MTP Cabling System
MTP cabling architectures utilise varying cable and patchcord configurations as defined in TIA-568-C.0-2. These cables vary by gender, fibre orientation and pair management. AFL manufactures a large and
More informationTest Report Number: G CRT-039g
3933 US Route 11 Cortland, New York 145 Telephone: +1 () 345-3851 Facsimile: +1 (7) 758-6637 www.intertek.com Project Number: G28364 Certificate of Conformance Number: 324722CRT-1f Date Issued: 5/29/15
More informationOLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide
OLS Series Light Sources, OPM Series Optical Power Meters, and Related Test Kits User s Guide 2004-2009, AFL Telecommunications, all rights reserved. COM4-00-1001 Revision E, 2009-06-16 Specifications
More informationSpecialized Solutions for Fiber Optic Testing
Specialized Solutions for Fiber Optic Testing www.optotest.com 1.805.987.1700 OP740 High-Speed Multichannel Optical Power Meter The OP740 offers a state-of-the-art solution for highspeed optical power
More informationOptical Fiber Networks: Industry. and New Options for Networks
Optical Fiber Networks: Industry Trends, Application Influences and New Options for Networks Herbert V Congdon II, PE Manager, Standards & Technology Tyco Electronics AMP NETCONNECT Solutions Preview Deciding
More informationEDGE Solutions Trunk Cable, OM4, Low- Loss, MTP to MTP, 12 fibres
EDGE MTP trunks are preterminated cables with 12 -fibre MTP connectors or LC duplex connectors on either side. The trunks build up the major skeleton of the passive network infrastructure, and thanks to
More informationHIGH DENSITY DATA CENTER CABLING GUIDE. Optics DACs Cables Cable Management Fiber TAPs Media Converters
HIGH DENSITY DATA CENTER CABLING GUIDE Optics DACs Cables Cable Management Fiber TAPs Media Converters PROVIDING MTP CABLING SOLUTIONS FOR THE SMART DATA CENTER. APPROVED NETWORKS SETS THE STANDARD The
More informationPretium EDGE Solutions Trunk Cable, OM3, Low-Loss, MTP to MTP, 24 fibres
Corning LANscape Pretium EDGE (Evolved-Density, Growth -Enabled) solutions are high -density preterminated optical cabling systems that simplify installation and improve performance in data centre environments.
More informationChoosing MPO Connectors for the Data Center. Ken Hall, RCDD, NTS Data Center Architect CommScope
Choosing MPO Connectors for the Data Center Ken Hall, RCDD, NTS Data Center Architect CommScope Agenda Network Architecture changes Data Center & MPO Standards Application comparisons Additional considerations
More informationEDGE Solutions Hybrid Trunk, OM4, Low- Loss, MTP to LC Duplex Uniboot, 24 fibres
EDGE MTP trunks are preterminated cables with 12 -fibre MTP connectors or LC duplex connectors on either side. The trunks build up the major skeleton of the passive network infrastructure, and thanks to
More informationHistory of Standards
History of Standards From 10Mbps to 100Gbps Ethernet 12 th May 2014 Gautier Humbert, RCDD Business Development Manager Legrand East and Central Europe Agenda 1- Current standards and their structures
More informationSignature Core Fiber Optic Cabling System
White Paper June 2012 WP-17 Signature Core Fiber Optic Cabling System Multimode Fiber: Understanding Chromatic Dispersion Introduction The performance and reliability of networks within the Data Center
More informationSumitomo Fiber Specification SE-5** PureBand Single-Mode Fiber. Zero Water Peak (ZWP) Attenuation Optical Fiber, ITU G.
Sumitomo Fiber Specification SE-5** PureBand Single-Mode Fiber Zero Water Peak (ZWP) Attenuation Optical Fiber, ITU G.652D TIA Type IVa Issued: March 2009 78 Alexander Drive, Research Triangle Park, NC
More informationCisco 25GBASE SFP28 Modules
Data Sheet Cisco 25GBASE SFP28 Modules Product Overview The Cisco 25GBASE SFP28 (Small Form-Factor Pluggable) portfolio offers customers a wide variety of highdensity and low-power 25 Gigabit Ethernet
More information100G SWDM4 MSA Technical Specifications Optical Specifications
100G SWDM4 MSA Technical Specifications Specifications Participants Editor David Lewis, LUMENTUM The following companies were members of the SWDM MSA at the release of this specification: Company Commscope
More informationMaestro Wireless E206XT VZW OTAID: Mob_Firm_Rev = 101 Mob_Model = 15. Tested to:
731 Enterprise Drive Lexington, KY 40510 Open Development Lab Conformance Final Report Telephone: 859-226-1000 Facsimile: 859-226-1040 www.intertek-etlsemko.com Verizon Wireless 180 Washington Valley Drive
More informationMTP Outdoor Cabling System
The AFL MTPE (MTP Elite) Low Loss outdoor cabling system offers a market leading, low loss, fast and efficient connection system for underground (UG) and outside plant applications. These assemblies offer
More informationFiber in Data Centers What s Next? Srinivasan B, RCDD
Fiber in Data Centers What s Next? Srinivasan B, RCDD Hubbell Fiber Systems 10G / 40G / 100G / 400G Standards, Applications and Practices Agenda Part 1: Current Technologies Standards Review IEEE 802.3:
More informationPANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY
PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PANGEN INDUSTRIAL AUTOMATION SYSTEM WARRANTY WARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents
More informationEDGE8 MTP Trunk Cable
The EDGE8 trunks utilise 8 -fibre push/pull optical connectors that are pinned on both ends of the cable. The trunks are shipped with strain -relief clips that allow for tool -less installation in EDGE8
More informationMTP Multi Lite Trunk Assemblies
MTP Multi Lite Trunk Assemblies MTP Multi-Lite Trunk assemblies are a neat solution for providing up to four MTP -MTP links within a compact, high density ruggedised cable. The cable construction consists
More informationCERTIFICATION PLUS SM
CERTIFICATION PLUS SM SYSTEM WARRANTY PROGRAM Panduit Warranty Guide PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction & Installation
More informationPluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables
DATASHEET Pluggable Transceivers Industry standard Pluggable Transceivers and Direct Attach Cables Product Overview Modular Ethernet interfaces from 100Mbps to 40Gbps Support for a large variety of cable
More informationFiberSolutions. Fiber Optic Cable & Assembly Solutions
Solutions Optic Cable & Assembly Solutions Solutions MOHAWK FIBER OPTIC CABLE AND ASSEMBLY SOLUTIONS Today s fast paced world places an unyielding burden on data centers to deliver high performance and
More informationAre Conflicts in Data Center Fiber Optic Structured Cabling Standards Putting Your Organization at Risk?
Are Conflicts in Data Center Fiber Optic Structured Cabling Standards Putting Your Organization at Risk? Rick Dallmann Senior Data Center Infrastructure Architect CABLExpress 36 Years of Experience CABLExpress
More informationStandards Update. Mylaraiah J N, RCDD Member, BICSI India Steering Committee
Standards Update Mylaraiah J N, RCDD Member, BICSI India Steering Committee Standards Update International Standards Interrelations Reference Guide Standard ISO/IEC CENELEC TIA/EIA Performance / Generic
More informationCisco 10GBASE SFP+ Modules
Data Sheet Cisco 10GBASE SFP+ Modules Product Overview The Cisco 10GBASE SFP+ modules (Figure 1) offer customers a wide variety of 10 Gigabit Ethernet connectivity options for data center, enterprise wiring
More informationElectrical & Optical Interfaces of TOSA EMwL
Multi-source Agreement (MSA) of 10 Gbit/s Miniature Device (XMD) XMD02 Electrical & Optical Interfaces of TOSA EMwL Rev. 1.2 January 17, 2006 Description This technical document has been created by the
More information40 Gigabit QSFP CWDM 1310 nm LR4 for 10 km
Features 4 CWDM lanes MUX/DEMUX design Up to 11.2Gbps data rate per wavelength QSFP MSA compliant Up to 10km transmission Operating case temperature: 0~70C Maximum 3.5W operation power RoHS compliant Applications
More informationSUMITOMO SPECIFICATION. FutureFLEX. Multimode 62.5 µm Core Optical Fiber (OM1) Gigabit Grade
SUMITOMO SPECIFICATION FutureFLEX Multimode 62.5 µm Core Optical Fiber (OM1) Gigabit Grade SUMITOMO ELECTRIC LIGHTWAVE CORP. 201 South Rogers Lane, Suite 100, Raleigh, NC 27610 (919) 541-8100 or 1-800-358-7378
More informationCisco 100GBASE QSFP-100G Modules
Data Sheet Cisco 100GBASE QSFP-100G Modules Product Overview The Cisco 100GBASE Quad Small Form-Factor Pluggable (QSFP) portfolio offers customers a wide variety of high-density and low-power 100 Gigabit
More informationIs Your Network Ready for 100 Gig? Specifying Optical Fiber for the Next Generation
Is Your Network Ready for 100 Gig? Specifying Optical Fiber for the Next Generation John Kamino OFS Product Manager Multimode Fiber jkamino@ofsoptics.com Fiber Market Drivers Agenda Fiber Types and Standards
More informationFactory assembled FO cabling system with LC-Duplex adapter-interfaces in PURE quality, GHMT channel certified
Factory assembled FO cabling system with LC-Duplex adapter-interfaces in PURE quality, GHMT channel certified Our motivation for the development of is the requirement of today`s high performance transmission
More informationCisco Series Gigabit Ethernet Half-Height Line Card
Cisco 10000 Series Gigabit Ethernet Half-Height Line Card Figure 1. Cisco 10000 Series Gigabit Ethernet Half-Height Line Card In order to continue to meet customers increasing needs for modularity and
More informationData Center & Cloud Computing Infrastruture Solutions DATASHEET. Standard Fiber Patch Cable. Make high-speed Ethernet network equipment connections
Data Center & Cloud Computing Infrastruture Solutions DATASHEET Standard Fiber Patch Cable Make high-speed Ethernet network equipment connections 1 Description Fiber optic patch cables are ideal for supporting
More informationSTANDARDS REFERENCE GUIDE ANIXTER anixter.com. Products. Technology. Services. Delivered Globally.
ANSI/TIA-568-C.0 ANSI/TIA-568-C.1 ANSI/TIA-568-C.2 ANSI/TIA-568-C.3 ANSI/TIA-569-D ANSI/TIA-606-B ANSI/TIA-607-C ANSI/TIA-862-A ANSI/TIA-942-A ANSI/TIA-1005-A ANSI/TIA-1179 ISO/IEC 11801 IEEE 802.3af IEEE
More informationCommon Mistakes Made in Certification Specifications and Testing. Jim Davis Regional Marketing Engineer Fluke Networks
Common Mistakes Made in Certification Specifications and Testing Jim Davis Regional Marketing Engineer Fluke Networks Common Mistake #1 Failing to specify a Permanent Link test #1 Permanent Link or Channel?
More informationCisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications
Data Sheet Cisco Small Form-Factor Pluggable Modules for Gigabit Ethernet Applications The industry-standard Cisco Small Form-Factor Pluggable (SFP) Gigabit Interface Converter is a hot-swappable input/output
More informationCorrigendum 1 to Amendment 2 1 ISO/IEC ISO/IEC (second edition 2002) Information technology Generic cabling for customer premises
Corrigendum 1 to Amendment 2 1 ISO/IEC 11801 ISO/IEC 11801 (second edition 2002) Information technology Generic cabling for customer premises Amendment 2 (2010) CORRIGENDUM 1 Corrigendum 1 applies to Amendment
More informationCanadian Codes & Standards Updates
Canadian Codes & Standards Updates Canadian Codes & Standards Agenda: Which ones do we need to know? What are the latest versions What s changed in the latest versions? What did you miss? Standards Reference
More informationProCurve Mini-GBICs. Used with the following
ProCurve Mini-GBICs ProCurve Gigabit-SX-LC Mini-GBIC (J4858B) 1 1000Base-SX port (IEEE 802.3z Type 1000Base-SX) Connector: LC Dimensions (D x W x H): 5.69 x 1.37 x 1.23 cm (2.24 x 0.54 x 0.486 in.) Weight:
More informationIndoor Cable Application Note
Application Notes Indoor Cable Application Note Issued November 2013 Abstract With the fast development of fiber optic communication technology and the trend of FTTX, indoor fiber optic cables are more
More informationOptical Fiber Premises Standards News & Trends
1 Optical Fiber Premises Standards News & Trends Herb Congdon Tyco Electronics Updated: October 2005 hvcongdon@tycoelectronics.com 2 IEEE Ten Gigabit Ethernet (10GBASE-F) Published as IEEE802.3ae in June
More informationTarleton State University. Specifications
Tarleton State University Campus Communication Infrastructure Specifications Cabling Standards Summary This document identifies Tarleton State University communication infrastructure standards. The communication
More informationOptical Component Environmental Test System OCETS Plus Series
COMMUNICATIONS TEST & MEASUREMENT SOLUTIONS Optical Component Environmental Test System OCETS Plus Series Key Features High Return Loss option (HiRL) monitors RL up to 70 db Up to 210 device channels (420
More informationUsing Laser-Optimized Multimode Fiber for 1 and 10 Gigabit Campus Backbone Applications
Using Laser-Optimized Multimode Fiber for 1 and 10 Gigabit Campus Backbone Applications David Kozischek, Market Manager Enterprise Networks, Corning Optical Communications Systems engineers at Corning
More informationCisco 100GBASE QSFP-100G Modules
Data Sheet Cisco 100GBASE QSFP-100G Modules Product Overview The Cisco 100GBASE Quad Small Form-Factor Pluggable (QSFP) portfolio offers customers a wide variety of high-density and low-power 100 Gigabit
More informationSumitomo Fiber Specification SE-7** Non-Zero Dispersion Shifted Single-Mode Fiber. PureMetro SM Optical Fiber, TIA Type Ivd, ITU-T G.
Sumitomo Fiber Specification SE-7** Non-Zero Dispersion Shifted Single-Mode Fiber PureMetro SM Optical Fiber, TIA Type Ivd, ITU-T G.655 Issued: January 2006 CONTENTS 78 Alexander Drive, Research Triangle
More informationMcAfee Network Security Platform
Revision D McAfee Network Security Platform (M-series Transceiver Modules Reference Guide) COPYRIGHT Copyright 2018 McAfee, LLC TRADEMARK ATTRIBUTIONS McAfee and the McAfee logo, McAfee Active Protection,
More informationLAN Standards, News & Trends Update 2017 June 15, 2017
LAN Standards, News & Trends Update 2017 June 15, 2017 Greg Olson Jtech Systems, Inc Infrastructure Specialist Greg@jtechreps.com 425-437-1962 Our Objectives Review new & ongoing applications work in IEEE
More informationAccelerating Light STAR. Data Center High Density Connectivity Solution
Accelerating Light STAR Data Center High Density Connectivity Solution STAR High Density Connectivity Solution STAR is a cost-effective modular solution that harnesses ultra-high density pre-terminated
More informationFTTE Revisited for New Technologies
FTTE Revisited for New Technologies A new look into FTTE design to allow great flexibility as well as compliance to the latest 40G and 100G. Gautier Humbert, RCDD, CDCDP Business Development Manager Eastern
More informationGPP SRC 10Gbps SFP+ Optical Transceiver, 300m Reach
Features GPP-85192-SRC 10Gbps SFP+ Optical Transceiver, 300m Reach Optical interface compliant to IEEE 802.3ae 10GBASE-SR Electrical interface compliant to SFF-8431 Hot Pluggable 850nm VCSEL transmitter,
More informationDATA CENTER SYMPOSIUM
DATA CENTER SYMPOSIUM Dynamic Changes in Data Center Optic Transmissions & The Impact to Structured Fiber Cabling Rick Dallmann CABLExpress Years of Experience CABLExpress is a manufacturer of custom built
More informationVolition. Multimode VF-45 Socket and Patch Cords. 3Innovation
Volition Multimode VF-45 Socket and Patch Cords It's as easy as plugging in a rj-45. The Volition VF-45 Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnects for affordable, high
More informationSUPPLEMENTARY TYPE EXAMINATION CERTIFICATE
1. SUPPLEMENTARY TYPE EXAMINATION CERTIFICATE 2. Equipment or Protective System Intended for use in Potentially Explosive Atmospheres Directive 94/9/EC 3. Type Examination Certificate Number: ITS13ATEX47876X/1
More informationPANGEN SYSTEM WARRANTY. Warranty Guide
PANGEN SYSTEM WARRANTY Warranty Guide C2-10270 PANGEN SYSTEMWARRANTY GUIDE PROGRAM OUTLINE TABLE OF CONTENTS: MATERIALS PAGE # Program Outline 2 Table of Contents Warranty Information 3 Introduction &
More informationCable Assembly Test System. MS12001 System
Cable Assembly Test System KEY FEATURES MS10P is a powerful controller unit with 10 slots MS10E Expansion Chassis for up to 10 extra slots Remote control via Ethernet/GPIB card Turn-key software Local
More informationData center applications standards reference guide
White paper Data center applications standards reference guide Networking and storage Contents Scope 3 Introduction 3 Data center cabling standard ISO/IEC 24764 3 Ethernet (IEEE 802.3) 4 Proprietary 40
More informationProduct Classification. Construction Materials. Dimensions. Environmental Specifications. General Specifications. Mechanical Specifications
760200527 TeraSPEED FC APC to Unconnectorized, Fiber Patch Cord, 1.6 mm Simplex, Plenum Product Portfolio Brand Product Type CommScope TeraSPEED Fiber test patch cord Regional Availability Asia Australia/New
More informationA Fork in the Road OM5 vs. Single-Mode in the Data Center. Gary Bernstein, Sr. Director, Product Management, Network Solutions
A Fork in the Road OM5 vs. Single-Mode in the Data Center Gary Bernstein, Sr. Director, Product Management, Network Solutions Outline Definition of Enterprise and Cloud Data Centers The Growth of Cloud
More informationAtras Network Communications
Atras Network Communications Guide to Information and Communications Technology (ICT) Standards developed and published by the Telecommunications Industry Association (TIA) The Telecommunications Industry
More informationVolition. Multimode VF-45 Socket and Patch Cords. 3Innovation
Volition Multimode VF-45 Socket and Patch Cords O b D s oc ol e um te en t It's as easy as plugging in a rj-45. The Volition VF-45 Socket and Patch Cords from 3M are the latest duplex, fiber optic interconnects
More informationT A S A 1 E H
Specification Small Form Factor Pluggable Duplex LC Receptacle SFP28 Optical Transceivers Module 25GBASE-SR, CT Ordering Information T A S A 1 E H 1 8 3 4 Model Name Voltage Category Device type Interface
More informationOptimization and Speed: Two Critical Standards Enabling Next Generation Networks. Stephanie Montgomery, TIA Brett Lane, Panduit
Optimization and Speed: Two Critical Standards Enabling Next Generation Networks Stephanie Montgomery, TIA Brett Lane, Panduit Structure of TIA Standards 2 A family of Standards ANSI/TIA-942-A Telecommunications
More informationPolymer Coated Fiber Cable (PCF)
Polymer Coated Fiber Cable (PCF) Panduit has introduced a Polymer Coated Fiber (PCF) to their fiber cable offering available in 50µm and 62.5µm core diameters. Along with this cable having a stronger durability
More informationNOTICE. (Formulated under the cognizance of the CTA R7 Home Networks Committee.)
ANSI/CTA Standard Determination of Small Network Equipment Average Energy Consumption ANSI/CTA-2049 (Formerly ANSI/CEA-2049) February 2015 NOTICE Consumer Technology Association (CTA) Standards, Bulletins
More information10GB ETHERNET SFP+ ULTRA LOW POWER SR OPTICAL TRANSCEIVER
OPTICAL INTERCONNECT 10GB ETHERNET SFP+ ULTRA LOW POWER SR OPTICAL TRANSCEIVER OVERVIEW FCI s TRX10GVP2010C2 10Gb/s Ethernet 850nm Multi Mode SFP+ SR Optical Transceiver is designed for datacenter networking
More informationTRS5020EN-S001-W. Preliminary Technical Data (February 14 th, 2008)
Preliminary Technical Data (February 14 th, 2008) TRS5020EN-S001-W 10 Gigabit/s SFP+ Transceiver All specifications described herein are subject to change without prior notice TRS5020EN-S001-W: 10GBASE-LR
More informationStandards Update. by Paul Kish NORDX/CDT
Standards Update by Paul Kish NORDX/CDT Standards overview Category 5e cabling new transmission parameters patch cord return loss Category 6 cabling cable choices backwards compatibility Summary Outline
More informationTesting Parallel Optics
White Paper Testing Parallel Optics Author: Ed Gastle VIAVI Solutions To accommodate the relentless need for speed, driven by mobile devices, watching videos online and uploading and sharing content, network
More informationKI 2400/2800 SERIES HAND HELD FIBER SOURCE FEATURES. kingfisher.com.au. OPTICAL COMMUNICATIONS TEST APPLICATIONS (in combination with a power meter)
OPTICAL COMMUNICATIONS TEST APPLICATIONS (in combination with a power meter) Mixed single mode & multimode loss testing to 6 λ Multi-Fiber continuity & polarity testing Encircled Flux compliant testing
More informationOLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide
OLS Series Light Sources, OPM Series Optical Power Meters, and Optical Loss Test Kits Quick Reference Guide Warranty All NOYES test equipment products are warranted for a period of (1) one year from the
More informationTO THE BID PACKAGE FOR COUNTY OF INYO NETWORK PROJECT. This addendum is being issued to modify portions of the Bid Package for the Project entitled:
ADDENDUM NO. 2 TO THE BID PACKAGE FOR February 6, 2006 This addendum is being issued to modify portions of the Bid Package for the Project entitled: Receipt of this Addendum should be acknowledged by inserting
More information40G QSFP+ (MPO) to 4x10G SFP+ (8xLC) Assembly
Product updated on January 05, 2018 40G QSFP+ (MPO) to 4x10G SFP+ (8xLC) Assembly 40G parallel optics transceivers (40GBASE-SR4) can support 4x10G modes this feature allow new parallel optics active equipment
More informationTest Equipment Depot Washington Street Melrose, MA TestEquipmentDepot.com. FiberTEK III
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 - TestEquipmentDepot.com FiberTEK III User Manual Page 1 COPYRIGHT NOTICE The information contained in this document is the property
More informationA Closer Look at Plug and Play MPO/MTP Assemblies
WP_MTPAssemblies_D.qxp_D 11/29/16 3:05 PM Page 1 A Closer Look at Plug and Play MPO/MTP Assemblies The Internet of Things (IoT) and Big Data are driving the need for more bandwidth and increased transmission
More information10-GbE XFP and SFP+ Transceiver Modules
LXP-10G-MMLC LXP-10G-SMCL10 LXP-10G-CX4 Product Data Sheet 10-GbE XFP and SFP+ Transceiver Modules Overview The 10-GbE XFP and SFP+ Transceiver Modules enable you to take advantage of 10-GbE connectivity.
More information