Gambro Renal Products Technical Assistance Services. Technical Update PH,GI, /2008 GENERAL INFORMATION Equipment Type: Phoenix.

Size: px
Start display at page:

Download "Gambro Renal Products Technical Assistance Services. Technical Update PH,GI, /2008 GENERAL INFORMATION Equipment Type: Phoenix."

Transcription

1 Gambro Renal Products Technical Assistance Services 800/ / Technical Update PH,GI, /2008 GENERAL INFORMATION Equipment Type: Phoenix Subject: From: Communications Phoenix - Primer Charles Zuelchner This document is a primer for communications between the Gambro Phoenix dialysis machine and all Ethernet-based data collection software such as Exalis, Davita Snappy, and others. This does not cover CentryNet communications. This document includes definitions and general information for Phoenix in the following categories. Network Settings External Connections Internal Hardware Please read and understand this document first, then proceed to the specific "Troubleshooting" or "Configuration" document specific to your needs. The following "troubleshooting" and "configuration" Technical Updates provide detailed step-by-step instructions for particular systems. Communication Phoenix Configuration Exalis Communication Phoenix - Configuration Davita Communication Phoenix Configuration Other (all brands other than Exalis or Davita) Communication Phoenix - Troubleshooting CentryNet is not covered by these documents. For CentryNet, read the following. Technical Update "Communications CentryNet - Configuration". Technical Update "Communications CentryNet - Troubleshooting". "CentryNet Operations Guide" - A printed version of the manual was shipped with your CentryNet software. An electronic copy of the manual for CentryNet 3.0 may be viewed by clicking the CentryNet menu "Help Operations Guide" and clicking "TOC" for Table of Contents. Page 1 of 19

2 Table of Contents 1. Network Settings Touchscreen and Control Panel Finding the Blue Startup Screen Reading the Blue Startup Screen Comm Screens To reach the Comm Screens: Comm Screen Comm Screen Net Config Screens To reach the Net Config Screens Net Config Screens 1 and Summary of Important Points Exterior Connections Phoenix Port Wall Port Network Cable Interior Hardware Internal Ethernet Cable Ethernet Interface Card PC104 & Carrier Boards Summary Network Settings This section describes Phoenix Network Settings -- the location and operation of the various Ethernetrelated software items on the Phoenix dialysis machine. There are a total of 5 screens on the Phoenix that display network-related information. Blue Startup Screen - appears briefly about 35 seconds after power-on. Comm Screen 1 - has the Phoenix IP and Mask, as well as the CCM ID (MachineID). Comm Screen 2 - has the Gateway IP as well as the Net Route1 IP and Mask. Net Config Screen 1 - has the Secure Level IP and Mask for both Level 1 and Level 2. Net Config Screen 2 - has the Secure Level IP and Mask for both Level 3 and Level 4. In addition, the Online Icon is visible on the lower left of most screens when the Phoenix is online. Note: The Blue Startup Screen always displays the actual Network Settings. The Comm and Net Config screens allow you to change the Network Settings. Reloading Phoenix software erases your Network Settings. Because the Blue Startup Screen always displays the actual Network Settings, it is best to start with the Blue Screen when you are troubleshooting Network Settings. The Comm and Net Config screens do not show the actual settings until AFTER all values have been confirmed one time. This "initial confirmation" must be repeated each time you reload Phoenix software. The blue screen will always show the updated values. Page 2 of 19

3 1.1. Touchscreen and Control Panel The front of the Phoenix has a Touchscreen color display and below that is a Control Panel. The Touchscreen has Navigation Keys, Action Keys, Parameter Keys, Icons, and Status Area. The Control Panel has buttons. Navigation Keys are located at the bottom of the Touchscreen and are used for navigating to different screens. Action Keys are located on the right side of the Touchscreen. Action Keys either perform a command or display a new set of keys similar to navigation. Parameter Keys contain values that are edited using the "+/-" buttons. Parameter Keys are normally gray, but they turn yellow when selected with a tap of the finger. When a Parameter Key is yellow, the "+/-" buttons can change the value. Icons are located on the left side of the Touchscreen and are for display and notification only. Buttons are located on the Control Panel below the Touchscreen. This document only covers the four buttons on the right which are used for editing values. The following values (described later in more detail) should be displayed clearly on the front of the Phoenix for easy visibility. Place the numbers to the left or right side of the screen. It is recommended to NOT place any of these numbers on the Phoenix lid, since lids can be swapped between machines causing confusion between the labelled values and the actual values. The same applies to placing "asset labels" or marking serial numbers on the front of a Phoenix. CCM IDENTIF - Machine ID, use a large font that is visible from across the room. IP ADDRESS and SUBNET MASK. GATEWAY (if required). Page 3 of 19

4 The most important Navigation Keys, Action Keys, Icons and Status for Network Settings are shown below. They are defined as follows. HOME Navigation Key - navigates to the "home" screen shown above. CONFIG Navigation Key - navigates to the Comm Screens MACHINE Navigation Key - navigates to the Net Config Screens IDLE mode - this icon displays the current mode of the Phoenix. Network Settings are only accessible in Idle mode. ONLINE icon - is visible when the Phoenix is online; not visible when Phoenix is offline. TheControl Panel buttons important for Network Settings are shown below. SET button - toggles between showing and hiding Parameter Keys so you can change values of the keys that are pertinent to this screen. +/- buttons - change values for the selected Parameter Key. The key must be selected first, that is, tap the key so it turns yellow before using +/-. CONFIRM button - stores the current value for the selected Parameter Key. That is, if a key is yellow, pressing the CONFIRM button stores the value. Page 4 of 19

5 1.2. Finding the Blue Startup Screen When you power-on the Phoenix, the following sequence of startup screens appears at the designated times. The important screen is the 4th one that appears about 35 seconds after power-on. We call this the "Blue Startup Screen" and it contains the actual Network Settings. Time After Power-on Sample Startup Screen 3 seconds System startup in progress 13 seconds Boot from ATAPI CD-ROM : 26 seconds Vx Works System Boot Loading OS 35 seconds Blue Startup Screen IP Address < : > Default Gateway < > No Secure Level enabled Loading Modules Page 5 of 19

6 1.3. Reading the Blue Startup Screen The Blue Startup screen will have two or three rows of network configuration depending on whether your network requires a Gateway IP Address. The IT staff that built your network will decide whether a Gateway IP Address is required. If your network does NOT require a Gateway IP Address, then your Blue Startup screen has 2 lines. Line 1 is the Phoenix IP Address followed by the Phoenix IP Mask. Line 2 is the Phoenix firewall (must read "No Secure Level enabled"). IP Address < : > No Secure Level enabled Loading Modules If your network requires a Gateway IP Address, then your Blue Startup screen has 3 lines. Line 1 is the Phoenix IP Address followed by the Phoenix IP Mask. Line 2 is the Gateway IP Address. Line 3 is the Phoenix firewall (must read "No Secure Level enabled"). IP Address < : > Default Gateway < > No Secure Level enabled Loading Modules Example Error #1: In the example below, we have an error -- the third line does not say "No Secure Level enabled". The text "Secure Level Nr 1" indicates that on Net Config Screen 1 or 2 a Parameter Key has not been zeroed out completely. A common cause is forgetting to confirm a Parameter Key that already had a zero value. The solution is to reconfirm ALL keys on both Net Config Screens, even if they already display a correct value. Example Error #2: In the example below, we have an error -- the second line has extra text referring to "Net Route1". This indicates that the Net Route1 IP or Net Route Mask on the Comm Screen 2 has not been zeroed out completely. A common cause is forgetting to confirm a Parameter Key that already had a zero. The solution is to reconfirm ALL keys on Comm Screen 2, even if they already display a correct value. Page 6 of 19

7 1.4. Comm Screens There are two network "Comm" screens: Comm Screen 1 and Comm Screen To reach the Comm Screens: To reach the Comm Screens, perform the following steps. Ensure the Phoenix is in Idle mode. Select the Navigation Keys: HOME CONFIG MACHINE COMM. Press the SET button. Comm Screen 1 is now visible. Comm Screen 2 is visible by tapping the NEXT button, but only if COMM SYSTEM is set to 'RIMS' on Comm Screen 1. For Exalis users, set COMM SYSTEM = 'RIMS' in order to configure Comm Screen 2 and then return to Comm Screen 1 and revert to COMM SYSTEM = 'EXALIS'. Below is a visual representation of the same steps. (To return to the HOME screen press SET and HOME.) To reach the Comm Screens: Page 7 of 19

8 Comm Screen 1 Comm Screen 1 contains the following important Parameter Keys. CCM IDENTIF - (CCM ID) the Machine ID of this Phoenix. COMM SYSTEM - the type of software communicating with your Phoenix. OFFLINE TIMEOUT - the amount of time with no communication before the Online Icon disappears. Generally, 01:30 (90 seconds) is OK. IP ADDRESS - the network address of this Phoenix (4 keys). SUBNET MASK - determines the subnet of this Phoenix (4 keys). Important Points The CCM ID is unique -- no other Phoenix may have the same value. CCM ID means 'Machine ID'. In most dialysis units, the BioMed determines the ID. The 4th number of the IP ADDRESS is unique. No other Phoenix may have the same value. COMM SYSTEM is set to 'RIMS' when using non-gambro software and to 'EXALIS' when using the Gambro Exalis software. All other values on this screen (as well as all values on the other COMM and NET CONFIG screens) will be identical for all Phoenix in the same dialysis unit. This means that if one Phoenix needs to be reconfigured, you can look at any other working Phoenix to get all values but two. A key for "STATION ID" is visible when COMM SYSTEM equals "EXALIS". Do not confuse Station ID with Machine ID (CCM ID). Leave the Station ID at the default value of "50" unless you require the Exalis "auto-layout" feature. "RIMS" users will ignore STATION ID. Page 8 of 19

9 Comm Screen 2 Comm Screen 2 contains the following important Parameter Keys. GATEWAY - Gateway IP for your network if it has a gateway. NET ROUTE1 - all zeroes. MASK ROUTE1 - all zeroes. If your network requires a Gateway address, enter your Gateway here. NET ROUTE1 and MASK ROUTE1 are always all zeroes. Remember to re-confirm ALL keys even if they already have the correct value. If your network does not require a Gateway address, then enter all zeroes. Remember to re-confirm ALL keys even if they already have the correct value. Page 9 of 19

10 1.5. Net Config Screens There are two network "Net Config" screens: Net Config Screen 1 and Net Config Screen 2. The two screens look almost the same To reach the Net Config Screens To reach the Net Config Screens, perform the following steps. Ensure the Phoenix is in Idle mode. Select the Navigation Keys: HOME MACHINE CALIB. Press the SET Button. Tap the "PASSWORD CODE" Parameter Key so it turns yellow. Use the +/- Buttons to set the value to (hint: the '-' key is quicker). Press the CONFIRM Button. Press the SET Button. Press the Action Keys: OPERATIONS MAIN SETTING NET CONFIG. Press the SET Button. Net Config Screen 1 is now visible. Net Config Screen 2 is visible by tapping the NEXT key. On the following page is a visual representation of how to reach the Net Config screens. To return to the HOME screen, perform the following steps. Press the SET button to get out of 'edit-mode', if necessary. Press the "CLOSE" Action Key 3 times. Allow a few seconds for the HOME screen to settle before restarting the Phoenix. To restart the Phoenix, turn the power Off, wait 5 seconds, then turn the power On. A restart is necessary to accept to new network settings. Verify that the Blue Screen shows the Correct Settings during this restart. Now the Phoenix Network Settings are fully configured. Page 10 of 19

11 To reach the Net Config Screens: Page 11 of 19

12 Net Config Screens 1 and 2 The Net Config Screens 1 and 2 contain a list of security filter addresses. Set all values on both screens to zero. Re-confirm ALL keys even if they already have the correct value The Net Config Screens 1 and 2 contain a list of security filter addresses. The intention is similar to a firewall in that you can limit the addresses that a Phoenix will respond to. However, in actual use it is preferable to use the robust firewall and security of your own network rather than to push this task onto the Phoenix. Improperly set filter addresses will block communications with your Phoenix, so it is always simpler to set all values to zero. Setting all values to zero disables security filtering. Net Config Screen 1 contains the following important Parameter Keys. ADDR 1st LEVEL - 1st firewall filter (all zeroes). MASK 1st LEVEL - 1st firewall filter mask (all zeroes). ADDR 2nd LEVEL - 2nd firewall filter (all zeroes). MASK 2nd LEVEL - 2nd firewall filter mask (all zeroes). NEXT - go to Net Config Screen 2. Net Config Screen 2 contains the following important Parameter Keys. ADDR 3rd LEVEL - 3rd firewall filter (all zeroes). MASK 3rd LEVEL - 3rd firewall filter mask (all zeroes). ADDR 4th LEVEL - 4th firewall filter (all zeroes). MASK 4th LEVEL - 4th firewall filter mask (all zeroes). PREV - go to Net Config Screen 1. Net Config Screen 1 Net Config Screen 2 There are a total of 32 Parameter Keys (16 keys on each screen). Set all values to zero. Remember to re-confirm ALL keys even if they already have the correct value. Page 12 of 19

13 1.6. Summary of Important Points Blue Startup Screen The Blue Startup Screen is only visible when restarting the Phoenix. The Blue Startup Screen ALWAYS displays the actual network settings. The Blue Startup Screen only displays settings -- you can not change settings here. Online Icon The Online Icon appears on the lower left side of the screen immediately after communications begin with the Phoenix. The Online Icon does not disappear immediately upon loss of communications. It disappears after 'Timeout' number of seconds. The default value is 1:30 (that's 1 minute and 30 seconds) and can be set on Comm Screen 1. Comm and Net Config Screens The Comm and Net Config screens allow changes to the Phoenix Network Settings. The Comm and Net Config screens are only accessible while the Phoenix is in Idle mode. The network settings displayed on the Comm and Net Config screens are only valid after EVERY value has been confirmed once on all screens. The Blue Startup Screen ALWAYS displays the actual network settings. The following buttons are found on the Control Panel below the screen: SET, CONFIRM (arrow), PLUS (+), and MINUS (-). Navigate to the Comm Screens using the Navigation Keys CONFIG MACHINE COMM and the SET button. Navigate to the Net Config Screens using the Navigation Keys MACHINE CALIB and the buttons SET, PASSWORD=65505, CONFIRM, SET, OPERATIONS MAIN SETTING NET CONFIG and SET. To confirm a value, tap the Parameter Key so it turns yellow, set the correct value (using the +/- buttons), then press the Confirm button. If the key already has the correct value, then just tap it and confirm it. Remember: "Confirm" means turn it yellow, then press the CONFIRM button. Preferably confirm the screens in order: Comm Screen 1, Comm Screen 2, Net Config Screen 1, and Net Config Screen 2. After reloading software or after using the Tech Card to perform a "Card-to-Config", the network settings on the Comm and Net Config screens will NOT match the actual settings on the Blue Startup screen. Re-confirm ALL values on Comm and Net Config screens. Even if a key already displays the correct value, it must be re-confirmed. Once all values have been confirmed, then the Comm and Net Config screens match the Blue Screen. For a particular dialysis unit, all Phoenix have the same network settings except for the CCM ID and the 4th number of the IP Address. This means you can use a working Phoenix in order to determine all of the network settings except CCM ID and the 4th number of the IP Address. Reloading software erases your Network Settings. Label your Phoenix with the Network Settings: CCM ID, IP Address, Subnet Mask, Gateway. This allows easy reconfiguration of Network Settings when software is reloaded. Do not put CCM ID and IP labels on the removeable lid of the Phoenix, because lids can easily get swapped. Do not confuse Station ID with Machine ID (CCM ID). Machine ID (CCM ID) is the unique identifier for each Phoenix. Page 13 of 19

14 2. Exterior Connections There are three exterior components related to the network as shown below. Phoenix Port Wall Port Network Cable (external Network Cable) Page 14 of 19

15 2.1. Phoenix Port The Phoenix Port is an RJ-45 connector. It is the same type connector used by standard computers and it looks like a large telephone plug. The Phoenix Port is located on the back of the Phoenix. Looking at the back of the Phoenix, the Phoenix Port is on a panel on the upper left -- the same panel where the blood pressure cuff hose connects. The Phoenix Port is clearly marked "ETHERNET" Wall Port The Wall Port is also an RJ-45 connector. It is the same type connector used by standard computers and it looks like a large telephone plug. Your IT department will determine which ports are designated for Phoenix dialysis machines. The Wall Port may be any color. There may be a single plug or multiple plugs. It is a good idea to mark the ports that are designated for Phoenix dialysis machines. Plugging into a regular computer port will cause communications to fail -- as if the cable were not plugged in Network Cable The Network Cable connects the Phoenix Port to the Wall Port. This is a standard CAT-5 Ethernet cable as used for standard computers. Use a cable that is long enough to prevent yanking of the cable when floorcleaning crews move the Phoenix and when patients recline in their dialysis chairs. Page 15 of 19

16 3. Interior Hardware Internal Hardware must be accessed by a qualified technician using anti-static handling skills. There are three internal components related to the network as shown below. Internal Ethernet Cable Ethernet Interface Card PC104 and Carrier Boards 3.1. Internal Ethernet Cable The Internal Ethernet Cable (Part # ) connects the Ethernet Interface Card to the ethernet port on the PC104 Board. The Internal Ethernet Cable routes behind the card cage on the right side of the Phoenix. The end of the cable with the 4-pin connector plugs into the Ethernet Interface Card. The end of the cable with the RJ-45 connector plugs into the ethernet port of the PC104 Card. Page 16 of 19

17 3.2. Ethernet Interface Card The Ethernet Interface Card (Part # ) isolates and protects the internal network components from the outside world. The Ethernet Interface Card is mounted on the inside of the back panel of the Phoenix. It has two connectors. Facing inward is a 4-pin connector -- the Internal Ethernet Cable plugs in here. Facing outward is an RJ-45 connector. Viewed from the outside of the Phoenix, this is called the Phoenix Port -- the Network Cable from a Wall Port plugs in here. When plugging in a Network Cable, ensure that the Phoenix power cable is plugged into the wall socket so that the Phoenix is grounded along with the external network. The Phoenix does not have to be powered on, but it must be grounded to avoid damage due to static electricity. For troubleshooting purposes the external Network Cable can be plugged directly into the PC104 Board INSIDE the Phoenix. This bypasses both the Ethernet Interface Card and Internal Ethernet Cable, allowing you to test if these two parts have failed. Page 17 of 19

18 3.3. PC104 & Carrier Boards The PC104 Board (Part # is ) is a small computer motherboard that contains the actual network port (ethernet port) of the Phoenix. The Internal Ethernet Cable plugs into the network port on the PC104 Board using a standard RJ-45 connector. The PC104 Board is mounted on top of the Carrier Board using 4 screws. The Carrier Board slides into the metal card cage. Always power-off the Phoenix before removing the PC104 or Carrier Boards. As described above, for troubleshooting purposes the external Network Cable can be plugged directly into the PC104 Network Port in order to bypass both the Ethernet Interface Card and Internal Ethernet Cable. This can tell you whether the Ethernet Interface Card or Internal Ethernet Cable are defective. The green and yellow LEDs for the Network Port are located just above the PC104 Network Port. A solid green LED signifies a "live" connection, that is, the PC104 Network Port detects a live port at the other end of the network. A blinking yellow LED signifies that this port is sending or receiving communication messages. Page 18 of 19

19 The underside of the PC104 Board houses the Compact Flash and the RAM. The Compact Flash holds all the Phoenix configuration settings including network settings. If a PC104 assembly is known to be defective, it is possible to swap Compact Flash or RAM with a known good unit in order to determine whether the defect is in the board or in a subcomponent. 4. Summary Upon completing the material in this document, proceed to the Technical Updates Communication Phoenix - Configuration Communication Phoenix - Troubleshooting The "Troubleshooting" and "Configuration" Technical Updates shown in the first section provide detailed step-by-step instructions for particular systems. Page 19 of 19

Print Server. User s Manual. Rev. 01 (April, 2004) Made In Taiwan

Print Server. User s Manual. Rev. 01 (April, 2004) Made In Taiwan Print Server User s Manual Rev. 01 (April, 2004) Made In Taiwan TABLE OF CONTENTS ABOUT THIS GUIDE... 4 INTRODUCTION... 5 PACKAGE CONTENTS... 6 SYSTEM REQUIREMENTS... 6 GENERAL FEATURES... 7 PRODUCT VIEW...

More information

Canlan INSTALLATION MANUAL

Canlan INSTALLATION MANUAL Canlan INSTALLATION MANUAL August 2014 Table of Contents Introduction... 4 Overview... 5 RJ45 Connector and Status LEDs... 5 Power Input... 6 RS232 / RS485 Connectors... 7 Installing the Canlan Software...

More information

BlueBridge. Networking Reference Guide

BlueBridge. Networking Reference Guide BlueBridge Networking Reference Guide BB-1616DT BlueBridge DSP BlueBridge TSD-BB44 4 Channel Digital Signal Processor ETHERNET IP RESET BlueBridge GREEN = SIGNAL RED = PEAK INPUT 1 INPUT 2 INPUT 3 IP INPUT

More information

Medium parts count, through-hole components (with exception of optional surface mount MAC IC).

Medium parts count, through-hole components (with exception of optional surface mount MAC IC). Introduction The E1.31 DMX Bridge is an interface intended to be used as part of a system to operate a lighting display that consists of DMX or Renard controlled dimmers. To form a complete system, the

More information

Simple Paging Start-Up Guide

Simple Paging Start-Up Guide Simple Paging Start-Up Guide About the Barix Simple Paging Solution The Barix Simple Paging solution is based on a number of Barix devices that come ready to use, enabling to you setup a paging system

More information

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I Table of Contents 1 Welcome Introducing the Avaya Wireless LAN 1-1 About the Access Point-I 1-2 Finding Information 1-3 2 Install your Access Point-I Overview 2-1 Verify Kit Contents 2-2 Write Down Product

More information

EDS8/16/32PR Quick Start Guide

EDS8/16/32PR Quick Start Guide Quick Start Guide 2007 Copyright Lantronix is a trademark of Lantronix. All rights reserved. 900-458 Rev. B 01/07 QUICK START GUIDE CONTENTS What s In the Box..........................................................2

More information

NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL. Windows 2000 Platform Description and Installation Instructions

NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL. Windows 2000 Platform Description and Installation Instructions NVM-Professional NVM-Server NVM-Server Desktop NVM-Server XL Windows 2000 Platform Description and Installation Instructions This manual has been developed by NEC America, Inc. It is intended for the use

More information

EQ7000. User Manual. Rev 1.00

EQ7000. User Manual. Rev 1.00 EQ7000 User Manual Rev 1.00 www.equustek.com Revision 1.00 February 27, 2009 Contents INTRODUCTION...4 ABOUT THIS MANUAL...4 INTENDED AUDIENCE...4 HARDWARE SPECIFICATIONS...5 PHYSICAL SPECIFICATIONS...5

More information

Hardware Installation Guide Installation (x3350)

Hardware Installation Guide Installation (x3350) Title page Nortel Application Gateway 2000 Nortel Application Gateway Release 6.3 Hardware Installation Guide Installation (x3350) Document Number: NN42400-300 Document Release: Standard 04.03 Date: January

More information

ProjectorNetTM Adapter Quick Start Guide

ProjectorNetTM Adapter Quick Start Guide ProjectorNetTM Adapter Quick Start Guide Adapter networking 1. Quick Start The ProjectorNet Adapter kit contains the following items: ProjectorNet Serial to Ethernet Adapter Cable Adapter, ProjectorNet

More information

SUPPORT ANDROID OS

SUPPORT ANDROID OS 360iQ Media Player SUPPORT +1 866 360-0121 ANDROID OS EZUniverse Inc.: One International Blvd., Suite 1105, Mahwah, NJ 07495-0400 Low cost platform for multi-camera display This low cost, Android OS based

More information

Initial Configuration on ML-Series Card

Initial Configuration on ML-Series Card CHAPTER 3 This chapter describes the initial configuration of the ML-Series card and contains the following major sections: Hardware Installation, page 3-1 Cisco IOS on the ML-Series Card, page 3-2 Startup

More information

How to Upgrade NIC OS to Windows Embedded Standard 7

How to Upgrade NIC OS to Windows Embedded Standard 7 Document Number: APL-00207 Updated 3/2/2015 Rev-A How to Upgrade NIC OS to Windows Embedded Standard 7 NIC units built between October 2010 and February 2015 were shipped with Windows Embedded Standard

More information

EtherNet/IP Communications Module

EtherNet/IP Communications Module EtherNet/IP Communications Module M/N RECOMM-ENET Firmware Version 2.xxx Firmware Version 3.xxx Instruction Manual D2-3510-1 The information in this manual is subject to change without notice. Throughout

More information

Part # Quick-Start Guide. SpeedStream 4200 Modem PPPoE Modem Router

Part # Quick-Start Guide. SpeedStream 4200 Modem PPPoE Modem Router Part # 007-0-00 Quick-Start Guide SpeedStream 00 Modem PPPoE Modem Router Before you begin, Verify that the following items came with your DSL kit: Step > Install Line Filters 7 SpeedStream Device Documentation

More information

RC-SV Configuration Guide Revision 3

RC-SV Configuration Guide Revision 3 Kramer Electronics, Ltd. RC-SV Configuration Guide Revision 3 Software Version 2.1.2.32 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version,

More information

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers

CRESCENDO /7200 G3. Quick Start Guide for Crescendo /7200. Processor Upgrade Card for Power Macintosh 7200/8200 Computers CRESCENDO /7200 G3 Processor Upgrade Card for Power Macintosh 7200/8200 Computers Quick Start Guide for Crescendo /7200 System Compatibility At this printing, processor upgrade cards are compatible with

More information

User s Guide. Ethernet Module for Barcode Printer

User s Guide. Ethernet Module for Barcode Printer User s Guide Ethernet Module for Barcode Printer 1. ETHERNET MODULE... 2 1-1. Functions... 2 1-2. General Specifications... 2 2. ETHERNET MODULE INSTALLATION... 3 2-1. Ethernet Module Installation for

More information

EEG DE361 HD BAS Decoder Product Manual

EEG DE361 HD BAS Decoder Product Manual EEG DE361 HD BAS Decoder Product Manual All rights reserved. [This page left intentionally blank] eeg Table Of Contents Introduction 2 Product Description... 2 Installation 3 Front Panel... 3 Rear Panel...

More information

Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0

Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0 Intel Server RAID Controller U2-1 Integration Guide For Microsoft* Windows NT* 4.0 Revision 1.0 February 2000 Revision History Revision Revision History Date 1.0 Initial Release 02/10/00 Intel Corporation

More information

# Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: or

# Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: or EQ7000 User Manual Rev 1.04 www.equustek.com Revision 1.04 Feb 20th, 2017 #286-5489 Byrne Rd, Burnaby, BC, V5J 3J1, Canada Phone: 888-387-3787 or 604-266-8547 www.equustek.com Page 1 Contents INTRODUCTION...4

More information

Getting Started. Overview of the Splash G3535

Getting Started. Overview of the Splash G3535 Getting Started This Getting Started explains how to unpack, install, and connect the Splash G3535 Color Server. After completing the tasks outlined in this guide, you can explore the features of the Splash

More information

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION

TABLE OF CONTENTS COPYRIGHT INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5 PREPARATION...5 CONFIGURATION SOLUTION TABLE...5

More information

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. M12 Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-M12

Industrial IP67-rated 4-Port 10/100/1000T at PoE + 2-Port 10/100/1000T. M12 Managed Ethernet Switch. (-40~75 degrees C) IGS-604HPT-M12 Industrial IP67-rated 4-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T M12 Managed Ethernet Switch (-40~75 degrees C) IGS-604HPT-M12 Quick Installation Guide Table of Contents 1. Package Contents...

More information

Introduction. EC2 User Manual with Technical Addendum 1.0 1

Introduction. EC2 User Manual with Technical Addendum 1.0 1 Introduction The EC2 Explorer Experience is a self-serve kiosk that simulates wind and reflective glare conditions. Key features that can aid the associate/customer in making a decision on their sunglass

More information

ez80190 Development Kit Quick Start Guide

ez80190 Development Kit Quick Start Guide Introduction Follow this guide to install and begin using your new ez80190 Development Kit from ZiLOG. The setup procedure guides the user through: Software installation and online registration Hardware

More information

Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2

Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2 Procedure to Upgrade from B&W Maintenance Panel to TIB Color Touchscreen Door in a Working Maxum or Maxum II Analyzer Equipped With a SYSCON2 Difficulty Level: High Estimated time to execute: 3 Hours Revision

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections, CTs, and Modbus....

More information

Longshine Technologie Europe GmbH

Longshine Technologie Europe GmbH Longshine Technologie Europe GmbH www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3 2. MFP SERVER INSTALLATION...5

More information

PMEUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

PMEUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA PMEUCM Hardware Manual PMEUCM Hardware Installation Manual This manual covers the PMEUCM hardware features and installation procedures. Effective: August 10, 2017 Niobrara Research & Development Corporation

More information

RC-SV Configuration Guide (Rev 4)

RC-SV Configuration Guide (Rev 4) Kramer Electronics, Ltd. RC-SV Configuration Guide (Rev 4) Software Version 2.1.2.69 Intended for Kramer Technical Personnel or external System Integrators. To check that you have the latest version, go

More information

HP Notebook PCs - Keyboard and TouchPad or ClickPad Guided Troubleshooter

HP Notebook PCs - Keyboard and TouchPad or ClickPad Guided Troubleshooter HP Notebook PCs - Keyboard and TouchPad or ClickPad Guided Troubleshooter This document applies to HP notebook computers. The keyboard, TouchPad, or ClickPad on your laptop is not working as expected:

More information

CLIQ.mini Installation and Setup Guide

CLIQ.mini Installation and Setup Guide CLIQ.mini Installation and Setup Guide Last modified: 04/06/18 Description The Clare Controls CLIQ.mini controller provides all device management services, supports all Clare user interface services, and

More information

BiPAC 8200M. BiPAC 8200N

BiPAC 8200M. BiPAC 8200N BiPAC 8200M VDSL2 Modem BiPAC 8200N Wireless-N VDSL2 Firewall Router Quick Start Guide Billion BiPAC 8200M VDSL2 Modem/ BiPAC 8200N Wireless-N VDSL2 Firewall Router PLEASE READ THE QUICK START GUIDE

More information

Pro10 Headset System

Pro10 Headset System Pro10 Headset System Installation Manual This guide specifies how the Pro10 headset system should be installed and commissioned. The LEDs on the, registration point and headset use a sequence of colours

More information

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver

Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver Longshine Technologie Europe GmbH LCS-MFP101-2 Multifunction Printserver www.longshine.de TABLE OF CONTENTS COPYRIGHT...2 1. INTRODUCTION...3 PRODUCT OVERVIEW...3 COMPONENTS AND FEATURES...3 HARDWARE INSTALLATION...3

More information

Part # Quick-Start Guide. SpeedStream Residential Gateway 5450 Four-Port Router

Part # Quick-Start Guide. SpeedStream Residential Gateway 5450 Four-Port Router Part # 007-6560-001 Quick-Start Guide SpeedStream Residential Gateway 5450 Four-Port Router Before you begin, Verify that the following items came with your DSL kit: 1 SpeedStream Device 2 Documentation

More information

Wireless Network Video Recorder

Wireless Network Video Recorder LD2R/LD2R500 Wireless Network Video Recorder User Guide Version 1.0 PREFACE Thank you for purchasing the Wireless Network Video Recorder, an IP based device that installed on your network, which can be

More information

Troubleshooting. Troubleshooting Overview CHAPTER

Troubleshooting. Troubleshooting Overview CHAPTER CHAPTER 4 This chapter provides basic installation troubleshooting information. The chapter includes the following sections: Overview Initialization and Self-Test Problems Subsystems Further Contacts This

More information

Ethernet Interface Module

Ethernet Interface Module Interface Manual 1 Ethernet Interface Module SignalFire Number: ENET-DIN The SignalFire Ethernet Gateway has the following features: - Wide range DC power input. 6 to 36VDC - Power Over Ethernet (POE)

More information

Using Alta ENET Products on Microsoft Windows Systems (Rich Wade, 6 SEP 13)

Using Alta ENET Products on Microsoft Windows Systems (Rich Wade, 6 SEP 13) Using Alta ENET Products on Microsoft Windows Systems (Rich Wade, 6 SEP 13) This document applies to all Alta ENET products (ENET-1553, ENET2-1553, ENET-A429, etc.) and provides step-by-step instructions

More information

Part # Quick-Start Guide. SpeedStream 6500 Residential Gateway

Part # Quick-Start Guide. SpeedStream 6500 Residential Gateway Part # 007-6510-001 Quick-Start Guide SpeedStream 6500 Residential Gateway Before you begin, Verify that the following items came with your DSL kit: Step 1 > Install Line Filters 1 2 4 5 6 1 SpeedStream

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E Rev. 2 December 2011 PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service.... 2 Disconnect Power Connections,

More information

Power Xpert Meter 2000 Gateway Card Kit

Power Xpert Meter 2000 Gateway Card Kit Quick Start Guide IL02601011E PXM 2250 PXM 2260 IQ 250 IQ 260 Power Xpert Meter 2000 Gateway Card Kit Table of Contents Remove the Meter From Service... 2 Disconnect Power Connections, CTs, and Modbus....

More information

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command

OPERATION MANUAL. MV-410HS Layout Editor. Version higher. Command OPERATION MANUAL MV-410HS Layout Editor Version 3.0 - higher Command Command Table of Contents 1. Setup... 1 1-1. Overview... 1 1-2. System Requirements... 1 1-3. Operation Flow... 1 1-4. Installing MV-410HS

More information

Home automation hub installation and setup guide

Home automation hub installation and setup guide installation and setup guide is placed in a closed off area, the wireless signal strength may be compromised. Note: To prevent radio frequency (RF) interference, we recommend that you place the away from

More information

TH800DS CONTROLLER MANUAL

TH800DS CONTROLLER MANUAL TH800DS CONTROLLER MANUAL 1 Introduction 3 1.1 Overview 3 1.2 Features 4 1.3 Specifications 4 1.4 Panel 5 1.4.1 Front Panel 5 1.4.2 Rear Panel 6 2 Hardware Installation 7 3 Accessing the Device 8 3.1 Before

More information

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA

DUCM Hardware. Niobrara Research & Development Corporation P.O. Box 3418 Joplin, MO USA DUCM Hardware Manual DUCM Hardware Installation Manual This manual covers the DUCM hardware features and installation procedures. Effective: May 29, 2015 Niobrara Research & Development Corporation P.O.

More information

VTRAK E-Class/J-Class Quick Start Guide

VTRAK E-Class/J-Class Quick Start Guide VTRAK E-Class/J-Class Quick Start Guide Version.0 Firmware 3.9 008 Promise Technology, Inc. All Rights Reserved. VTrak Quick Start Guide About This Guide This Quick Start Guide shows you how to install

More information

Industrial IP67-rated. 4-Port 10/100/1000T 802.3at PoE. + 2-Port 10/100/1000T. Managed Ethernet Switch (-40~75 degrees C, 24V) IGS MP2MT

Industrial IP67-rated. 4-Port 10/100/1000T 802.3at PoE. + 2-Port 10/100/1000T. Managed Ethernet Switch (-40~75 degrees C, 24V) IGS MP2MT Industrial IP67-rated 4-Port 10/100/1000T 802.3at PoE + 2-Port 10/100/1000T Managed Ethernet Switch (-40~75 degrees C, 24V) IGS-5227-4MP2MT Quick Installation Guide Table of Contents 1. Package Contents...

More information

Table of Contents. Keyspan:USB Server - User Manual

Table of Contents. Keyspan:USB Server - User Manual Table of Contents 1 Introduction Compatible USB Devices Connectivity to USB Devices Connectivity to Network Requirements What's Inside The Package 2 Installation Instructions Installing the USB Server

More information

Quick Installation Guide TS-I300 TS-I300W

Quick Installation Guide TS-I300 TS-I300W Quick Installation Guide TS-I300 TS-I300W Table of of Contents Contents... 1. Before You Start... 2. Hardware Installation... 3. Configure the Storage Server... 4. Accessing Storage Devices on TS-I300/TS-I300W...

More information

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH232Ex1. #1 RS-232 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH232Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH232Ex1 Doc No: PH232Ex1-UM-001 #1 RS-232 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

INTELLICAM SYSTEMS GEN IV Series Embedded Net DVR

INTELLICAM SYSTEMS GEN IV Series Embedded Net DVR GEN IV Series Embedded Net DVR G4-RTA Series H.264 Quick Reference User Guide Index HDD Installation & Format 2 Changing User Name & Password 3 Preview Screen 3, 4 Set Time & Date 4 Changing Camera Input

More information

Taurus - USB. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English)

Taurus - USB. User Manual. Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives. (English) Dual-Bay Storage Enclosure for 3.5 Serial ATA Hard Drives User Manual (English) v1.0 June 21, 2007 EN Table of Contents CHAPTER 1 - INTRODUCTION 1 CHAPTER 3 - SYSTEM SET UP 6 ICON KEY 1 THE TAURUS USB

More information

Installing the Cisco Unified Videoconferencing 3545 MCU

Installing the Cisco Unified Videoconferencing 3545 MCU CHAPTER 2 Installing the Cisco Unified Videoconferencing 3545 MCU The Cisco Unified Videoconferencing 3545 MCU works together with a Cisco Unified Videoconferencing 3545 EMP Enhanced Media Processor (EMP)

More information

Welcome Operation Installation... 3 Scope of function... 3 Pre-requirements... 3 Number of clients... 4 Version number...

Welcome Operation Installation... 3 Scope of function... 3 Pre-requirements... 3 Number of clients... 4 Version number... Contents Revox Joy S232 App 1 4 network receiver Contents Welcome... 3 Installation... 3 Scope of function... 3 Pre-requirements... 3 Number of clients... 4 Version number... 4 Operation... 5 Switching

More information

ProntoPro Intelligent Remote Control. User Guide

ProntoPro Intelligent Remote Control. User Guide ProntoPro Intelligent Remote Control User Guide Table of Content Taking a First Look... 3 Intelligent Remote Control... 3 Before You Start... 5 Getting Started... 7 Activating the Remote Control... 7 Defining

More information

HARMONi G3. Quick Start Guide for HARMONi G3. imac Processor/FireWire Upgrade

HARMONi G3. Quick Start Guide for HARMONi G3. imac Processor/FireWire Upgrade HARMONi G3 imac Processor/FireWire Upgrade imac and Operating System Compatibility The HARMONi G3 imac processor/firewire upgrade is compatible only with imac 233, 266, and 333 MHz models (Revisions A-D);

More information

RA Triage Procedure. Product: DM8050 & DM8600 series. 1.0 Useful Components & Accessories

RA Triage Procedure. Product: DM8050 & DM8600 series. 1.0 Useful Components & Accessories RA Triage Procedure Product: DM8050 & DM8600 series 1.0 Useful Components & Accessories 1.1 Cognex Single Port AC PoE Injector (Fig. 1) 1.2 USB cable (Fig. 2) 1.3 RS232 cable (Fig. 3) 1.4 WiFi or Bluetooth

More information

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items:

Application. Contents of Package. Inspect the CyberSwitch upon receipt. The package should contain the following items: Overview CyberPower power manager CyberSwitch is the ultimate power control center to manage multiple network devices via the Internet. After installing the hardware and setting up an IP address, this

More information

wificam User's Guide Report Version: Date: November

wificam User's Guide Report Version: Date: November User's Guide Report Version: 2.0.3 Date: November 9 2004 3JTech Co., Ltd. 342 Fu-Hsing N. Rd., 2F Taipei, Taiwan Tel: +886-2-2500 6919 e-mail: info@3jtech.com.tw 1 Revision History Version Date Changes

More information

Lifesize Icon Installation Guide October 2016

Lifesize Icon Installation Guide October 2016 Lifesize Icon Installation Guide October 2016 Lifesize Icon 400 Lifesize Icon 450 Lifesize Icon 600 Lifesize Icon 800 Preparing for Installation As you prepare to install your Lifesize video system, consider

More information

Table of Contents. Taking a First Look 2 Intelligent Remote Control 2 Before You Start 4

Table of Contents. Taking a First Look 2 Intelligent Remote Control 2 Before You Start 4 Table of Contents Taking a First Look 2 Intelligent Remote Control 2 Before You Start 4 Getting Started 6 Activating the Remote Control 6 Defining the Brands of Your Devices 7 Working with the Home Panel

More information

Nuance Field Certification Program 2-09

Nuance Field Certification Program 2-09 08/09/2013 PageCounter Professional (PCP) Equitrac Professional 3.5 (EP3.5) Nuance Field Certification Program 2-09 Nuance Document Imaging Paul Bahry NUANCE DOCUMENT IMAGING Paul Bahry PageCounter Professional

More information

Mega 100WR ADSL 2+ Router - Easy Start

Mega 100WR ADSL 2+ Router - Easy Start Mega 100WR ADSL 2+ Router - Easy Start Mega 100WR ADSL 2+ Router - Easy Start Chapter 1 Introduction Thank you for purchasing a Mega 100WR Router. This Easy start guide is a complete guide to configuring

More information

CHAPTER 7 ADVANCED ADMINISTRATION PC

CHAPTER 7 ADVANCED ADMINISTRATION PC ii Table of Contents CHAPTER 1 INTRODUCTION... 1 Broadband ADSL Router Features... 1 Package Contents... 3 Physical Details... 4 CHAPTER 2 INSTALLATION... 6 Requirements... 6 Procedure... 6 CHAPTER 3 SETUP...

More information

Kaleido-X16 Quick Start Guide

Kaleido-X16 Quick Start Guide Kaleido-X16 Quick Start Guide Questions about the Kaleido-X16? Telephone: +1-514-333-1772 e-mail: techsupp@miranda.com Comments and Suggestions about the Kaleido-X16 Documentation? e-mail: Documentation-Feedback@Miranda.com

More information

Quick Installation Guide DSL-2540U. ADSL Annex B/Ethernet Router with Built-in Switch

Quick Installation Guide DSL-2540U. ADSL Annex B/Ethernet Router with Built-in Switch ADSL Annex B/Ethernet Router with Built-in Switch BEFORE YOU BEGIN Delivery Package Router Power adapter DC 12V/0.5A RJ-11 telephone cable Ethernet cable (CAT 5E) Splitter CD-ROM with User Manual and (brochure).

More information

Peerless Drive System User's Manual

Peerless Drive System User's Manual Peerless Drive System User's Manual Copyright 2001 Iomega Corporation Iomega, the stylized "i" logo, Peerless, and the Peerless brand block are either registered trademarks or trademarks of Iomega Corporation

More information

HPE Intelligent Power Distribution Unit Installation Instructions

HPE Intelligent Power Distribution Unit Installation Instructions HPE Intelligent Power Distribution Unit Installation Instructions Important safety information For important safety, environmental, and regulatory information, see Safety and Compliance Information for

More information

Installation & Operations Manual

Installation & Operations Manual Installation & Operations Manual VoIP Command Center Made in the USA 3 Year Warranty N56W24720 N. Corporate Circle Sussex, WI 53089 800-451-1460 www.rathcommunications.com RP8500PBXVOIPG Ver. 3 10/18 Thank

More information

291-MB309-02N6F. PI331 pico

291-MB309-02N6F. PI331 pico 291-MB309-02N6F PI331 pico ZOTAC ZBOX pico User s Manual No part of this manual, including the products and software described in it, may be reproduced, transmitted, transcribed, stored in a retrieval

More information

DUAL SWITCH CONTROLLER

DUAL SWITCH CONTROLLER DUAL SWITCH CONTROLLER INSTRUCTION MANUAL IMPORTANT: If the Dual Switch Controller is to be used with a Dielectric 50000 Series Switch, control cable P/N 1100007364 or 11000007365 must be used. See Section

More information

Fortel FRM-501 Compact System Frame User Manual

Fortel FRM-501 Compact System Frame User Manual Fortel FRM-501 User Manual Document Number 81905906560, Rev A Original FortelDTV Text and Format December 2004 PESA Switching Systems 103 Quality Circle, Suite 210 Huntsville, AL 35806 USA Overview Fortel

More information

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix)

USER S MANUAL. PH485Ex1. #1 RS-485 Serial Port to Ethernet, Terminal Server/Client. Doc No: PH485Ex1-UM-001 IPEX. (IP Electronix) USER S MANUAL PH485Ex1 Doc No: PH485Ex1-UM-001 #1 RS-485 Serial Port to Ethernet, Terminal Server/Client IPEX (IP Electronix) Contents 1. INTRODUCTION... 3 2. SPECIFICATIONS... 3 3. PACKAGE CHECKLIST...

More information

BiPAC 7800DX(L) Dual-Band Wireless-N 3G/4G LTE (VPN) ADSL2+ Router. Quick Start Guide

BiPAC 7800DX(L) Dual-Band Wireless-N 3G/4G LTE (VPN) ADSL2+ Router. Quick Start Guide BiPAC 7800DX(L) Dual-Band Wireless-N 3G/4G LTE (VPN) ADSL2+ Router Quick Start Guide Quick Start Guide Billion BiPAC 7800DX(L) Dual-Band Wireless-N 3G/4G LTE (VPN) ADSL2+ Router PLEASE READ THE QUICK START

More information

Quick Start. Chapter. In This Chapter:

Quick Start. Chapter. In This Chapter: Chapter Quick Start In This Chapter: Getting to Know Windows.... - Installation of irectsoft 6.... - Getting Started.... -8 Welcome to irectsoft00.... - Begin Editing a Program.... -4 Establish the Communication

More information

Output Interfaces for SVS2000 TM Installation & Operation Manual

Output Interfaces for SVS2000 TM Installation & Operation Manual IOM Output Interfaces for SVS2000 TM Installation & Operation Manual Output Interfaces for SVS2000 TM Installation & Operation Manual CONTENTS I. INTRODUCTION... 1 II. INSTALLING THE OUTPUT INTERFACE...

More information

Physical Setup Obtaining New Firmware Performing a firmware Update Operating Specifications Troubleshooting...

Physical Setup Obtaining New Firmware Performing a firmware Update Operating Specifications Troubleshooting... PixCon16 E1.31 E1.31 16/32 Universe Pixel controller with 4 E1.31 to DMX bridge ports User Manual LOR PixCon16 Assistant August 27, 2015 V1.5 Copyright Light O Rama, Inc. 2015 Table of Contents Introduction...

More information

DataShuttle Xtreme Installation Guide

DataShuttle Xtreme Installation Guide DataShuttle Xtreme Installation Guide http://www.mcetech.com MCE DataShuttle Xtreme Installation Guide 1 Thank you for purchasing a new DataShuttle Xtreme Portable Hard Drive Kit from MCE! We are sure

More information

Internet Camera Quick Installation Guide

Internet Camera Quick Installation Guide Internet Camera Quick Installation Guide Rev. 01 (Dec, 2001) Q20011203 Printed In Taiwan Table of Content INTRODUCTION...2 SYSTEM REQUIREMENT...3 INTERNET CAMERA... 3 Network:...3 Recommended PC or Notebook

More information

ViZion DR + Wireless Install Guide

ViZion DR + Wireless Install Guide 1 ViZion DR + Wireless Install Guide 1. Open the DR panel box. 2. Put aside the three cables from the top layer of Styrofoam for storage. These cables are only required for potential troubleshooting scenarios.

More information

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment.

Film-Tech. The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. Film-Tech The information contained in this Adobe Acrobat pdf file is provided at your own risk and good judgment. These manuals are designed to facilitate the exchange of information related to cinema

More information

UTC Lupton Renaissance Fund Podium Users Manual

UTC Lupton Renaissance Fund Podium Users Manual UTC Lupton Renaissance Fund Podium Users Manual http://www.utc.edu/staff/charles-hart/utcp/utc_podiums.htm Remember Rule #1: When in doubt, press the RESET button! Podium Equipped Classroom User Guide

More information

WIRELESS ROUTER N150. User Manual. F9K1009v1 8820zb01125 Rev.B00

WIRELESS ROUTER N150. User Manual. F9K1009v1 8820zb01125 Rev.B00 WIRELESS ROUTER N150 User Manual F9K1009v1 8820zb01125 Rev.B00 TABLE OF CONTENTS Getting Started... 1 What s in the Box...1 Initial Setup...1 How to Set It UP...2 Adding Computers to Your Network...3 Manually

More information

Installing the Driver, Client Utility, and Client Adapter

Installing the Driver, Client Utility, and Client Adapter CHAPTER 3 Installing the Driver, Client Utility, and Client Adapter This chapter provides installation and configuration instructions for the driver, client utilities, and the client adapter. The following

More information

2004 Copyright BlackBox is a trademark of BlackBox. All rights reserved Rev. A 01/04. LES2700A-10 Quick Start Guide

2004 Copyright BlackBox is a trademark of BlackBox. All rights reserved Rev. A 01/04. LES2700A-10 Quick Start Guide 2004 Copyright BlackBox is a trademark of BlackBox. All rights reserved. 900-334 Rev. A 01/04 Quick Start Guide QUICK START CONTENTS Pinouts................................................................2

More information

DVG-6008S FXO VoIP Router

DVG-6008S FXO VoIP Router This product can be set up using Internet Explorer or Netscape Navigator, 6.x or above, with Javascript enabled DVG-6008S FXO VoIP Router Before You Begin You must have at least the following: A subscription

More information

Computer/Laptop Registration

Computer/Laptop Registration Computer/Laptop Registration Before you begin: You will need a valid KSU username and password. A computer or laptop with operating system of Windows (XP or higher) or Mac OSX. Confirm that your PC/laptop

More information

InTemp CX5000 Gateway Manual

InTemp CX5000 Gateway Manual InTemp CX5000 Manual The InTemp CX5000 is a device that uses Bluetooth Low Energy (BLE) to regularly download up to 50 CX series loggers and upload the data to the InTempConnect website automatically via

More information

CR3000 Copy Reader. Installation Guide

CR3000 Copy Reader. Installation Guide CR3000 Copy Reader Installation Guide CONTENTS CONTENTS 1 CR3000 Installation Guide 1 What you get: 2 Installation Overview 3 Install the Reader 4 Mount the Reader 4 Connect the Reader Cables 5 Connect

More information

Touch Panel Controller for CONVERGE Pro 2. With Built-in Dialers for VoIP/Telco & Skype for Business User Manual

Touch Panel Controller for CONVERGE Pro 2. With Built-in Dialers for VoIP/Telco & Skype for Business User Manual Touch Panel Controller for CONVERGE Pro 2 With Built-in Dialers for VoIP/Telco & Skype for Business Notices Technical Support Telephone 801.974.3760 Fax 1.801.303.5711 Email Web tech.support@clearone.com

More information

Appendix A: Metasys Web Access (MWA) Server Installation Guidelines

Appendix A: Metasys Web Access (MWA) Server Installation Guidelines Technical Bulletin Issue Date February 26, 2003 Appendix A: Metasys Web Access (MWA) Server Installation Guidelines Appendix A: Metasys Web Access Server Installation Guidelines...2 Introduction... 2 Detailed

More information

Sylphit-Duo DSK-Series. KVM Drawer (with integrated KVM switch)

Sylphit-Duo DSK-Series. KVM Drawer (with integrated KVM switch) Sylphit-Duo DSK-Series KVM Drawer (with integrated KVM switch) User Guide Version 1.0 Technology Corporation Rackit Technology Corporation 274 Madison Avenue, New York, NY 10016 Tel: (212) 679-0050 Fax:

More information

Quick Installation Guide DSL-2650U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch

Quick Installation Guide DSL-2650U/NRU. 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch DSL-2650U/NRU 3G/ADSL/Ethernet Router with Wi-Fi and Built-in Switch BEFORE YOU BEGIN Delivery Package Router DSL-2650U/NRU Power adapter RJ-11 telephone cable Straight-through Ethernet cable (CAT 5E)

More information

SVProxy3. User Guide

SVProxy3. User Guide SVProxy3 User Guide October 2010 Trademarks & Copyright Trademarks All trademarks mentioned in this manual are the sole property of their respective manufacturers. Copyright SerVision Ltd., Jerusalem,

More information

USB 2.0 Print Server. User s Manual. Rev. 01 (Jan, 2004) Made In Taiwan

USB 2.0 Print Server. User s Manual. Rev. 01 (Jan, 2004) Made In Taiwan USB 2.0 Print Server User s Manual Rev. 01 (Jan, 2004) Made In Taiwan TABLE OF CONTENTS ABOUT THIS GUIDE... 4 INTRODUCTION... 5 PACKAGE CONTENTS... 6 SYSTEM REQUIREMENTS... 6 GENERAL FEATURES... 7 PRODUCT

More information

VSX-60, SC-61, SC-63, SC-65, SC-67, SC-68

VSX-60, SC-61, SC-63, SC-65, SC-67, SC-68 Manufacturer: Model Number(s): Pioneer Integration Note VSX-60, SC-61, SC-63, SC-65, SC-67, SC-68 Core Module Version: Core Module 5.8 or later required Comments: VSX-60 with FW 1-157-076-014-091 tested.

More information