Series CA7 Contactors

Size: px
Start display at page:

Download "Series CA7 Contactors"

Transcription

1 Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line. The represents the most modern and flexible power contactor available today, meeting the highest industrial application requirements. Big performance in a small package wide selection of ten contactors in four frame sizes covers the entire horsepower range (up to 6/575V). Six of the contactors are only 5mm wide, an extremely small footprint for such rugged performance. number of design features account for this efficiency, including high contact pressure and bouncefree contacts, allowing the devices to handle the high starting currents typical of modern motors. Type and Type Coordination Whether you re designing motor circuits for use in North merica, Europe or any other part of the world, all contactors have been designed and tested with respect to Type and Type short circuit coordination. Find out more in the Technical Information section in this chapter. dvanced safety and reliability features The entire line features mechanically linked contacts, sometimes referred to as positively guided contacts or force guided contacts. If a main power pole welds, adequate clearances exist (.mm) to ensure that the auxiliary contacts do not change state when coil power is removed and the device tries to open. This is a requirement in safety circuits per IEC Reliability is further assured by crossstamped auxiliary contacts, which provide multi-point reliability in low current, low voltage applications. Three types of DC coils available -9C through C contactors are available with true DC or Electronic V DC coils that dramatically decrease wattage consumption during pull-in. This allows the use of smaller power supplies. The entire line is also available with a two winding DC coil that reduces the size of the contactor, as well as the hold-in values. Two winding coils include built-in coil suppression and an internal contact that bypasses the pull-in coil to the hold-in coil. 5mm ( / ) 9 6 5mm ( / ) 7 5mm ( /8 ) 7mm ( /6 ) SSN9 8

2 Modular accessories are common to all devices Reversible coil provides total flexibility ll accessories are interchangeable among all contactors and CS7 control relays. This minimizes inventory requirements and maximizes flexibility. Top and side mount auxiliary contacts are available depending on your application. mechanical interlock with two built-in NC auxiliaries also provides electrical interlocking if desired. Pneumatic and electronic timers, surge suppressors and electronic interface modules provide solutions for even the most complex applications. When shipped, both coil connections are normally located at the top of the contactor in preparation for mounting an overload relay at the bottom. For multi-starter panels, however, the coil can be reversed, which provides space to close-couple a KT7 Motor Circuit Controller on the top of the contactor. contactors can either be ordered with the coil reversed or may be easily reversed in the field. Dual power terminals speed wiring Top mounted coil Bottom mounted coil Reversible coils are standard on all contactors - through 85 contactors are designed with two power terminals for all three poles. This simplifies power wiring of interconnected contactors in reversing, reduced voltage and twospeed applications. Preformed power wiring connectors are also available for virtually instantaneous wiring in these labor intensive applications. Simplified wiring means less labor and less cost. Two power terminals on each pole Dual power terminals assure hassle-free wiring in complex control schemes Special use contactors for specialized applications The line has been expanded to include a number of contactors designed and labeled for specific industrial applications. In all cases, these devices are UL and CS approved for these specialized uses. CL7 Lighting Capacitor contactors CQ7 contactors manage the peak inrush common with capacitor switching by incorporating a built-in set of resistors and early-make contacts, wired in parallel with the power contacts, to pre-charge the capacitors. Selection is based on applied KVR. SSN9 Lighting contactors The CL7 contactor can be used to control a wide variety of lighting loads. These contactors are well suited to handle the high inrush currents typical of this application as well as other nonmotor (resistive) loads. Both mechanically held and electrically held models are available for lighting load applications up to, and 6. CNX Special Purpose CQ7 Capacitor Switching Sprecher + Schuh s expanded line includes contactors designed and labeled for specific industrial applications NEM Labeled CN7 contactors are UL Listed and rated in accordance with the requirements of NEM standards publication ICS-. These contactors are NEM compliant and are labeled accordingly. Special purpose contactors CNX contactors are standard contactors that have been tested, approved and labeled by UL for heating ventilation and air conditioning (HVC) applications. 9

3 - C Coil Three Pole - Series Non-Reversing, Three Pole With C Coil, Series (Open type only) ➊ [] ➊ Ratings for Switching C Motors (C / C / C) kw (5 Hz) UL/CS HP (6 Hz) Ø Ø uxiliary Contacts per C- C- V V / 5V 5V 69V 5V V V V 6V 575V NO NC Catalog Number Price 9 / / 5 7-/ / 7-/ / / / / / contactor --- contactor contactor Coil Codes ➋ C Coil Code Voltage Range 5 Hz 6 Hz Z V V V V 8 ~ 8V W ~ 8V-V V V 77 V 77V 8 8V-V V 8 V 8V 6 55v 6V Coil Terminal Position ll contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering contactors with reversed coils. ll contactors come with reversible coils. ➊ C Resistive Ratings and UL/CS Continuous Current Ratings may be increased by the use of Lug Kits or Paralleling Links. See ccessories section for applicable information. ➋ Other voltages available, see page 6. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. SSN9 Discount Schedule -

4 - C Coil Four Pole - Series Non-Reversing, Four Pole With C Coil, Series (Open type only) Ratings for Switching C Motors (C / C / C) Contact [] kw (5 Hz) UL/CS HP (6 Hz) Configuration, Ø Ø Main Pole C- C- V V 5V 5V 69V 5V V V V 6V 575V NO NC Catalog Number Price -9-M- 9 / / 5 7-/ -9-M- -9-M / 7-/ --M- --M- --M M- -6-M- -6-M / M- --M- --M M / M / M / M M- contactor Coil Codes ➊ C Coil Code Voltage Range 5 Hz 6 Hz Z V V V V 8 ~ 8V W ~ 8V-V V V 77 V 77V 8 8V-V V 8 V 8V 6 55V 6V SSN9 ➊ Other voltages available, see page 6. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. Discount Schedule -

5 - True DC Coil Three Pole - Series Non-Reversing, Three Pole With True DC Coil, Series (Open type only) ➊➍ Ratings for Switching C Motors (C / C / C) [] uxiliary kw (5 Hz) UL/CS HP (6 Hz) Contacts per ➊ Ø Ø V/ Catalog C- C- V 5V 5V 69V 5V V V V 6V 575V NO NC Number 9 / / 5 7-/ / 7-/ / / / / 5 Price -9C-- -9C C-- -C-- -6C-- -6C-- 5 -C-- -C-- 5 -C-- -C-- -C-- -7C-- -7C-- -7C-- -C-- -C-- -C C contactor (typical) -C-- contactor Description: True DC coils have low inrush which allows the use of smaller power supplies. See page 6 for more information. DC and C coils are not interchangeable. -9C C contactors have increased dimensions to accommodate true DC coils. Coil Codes ➋ DC Coil Codes D D ➌ 8D D D Voltage V V 8V V V Coil Terminal Position ll contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering contactors with reversed coils. ll contactors come with reversible coils. ➊ C Resistive Ratings and UL/CS Continuous Current Ratings may be increased by the use of Lug Kits or Paralleling Links. See ccessories section for applicable information. ➋ Other voltages available, see page 6. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➌ Surge suppressor coil with integrated diode available. Order coil code DD and add $ to list price. To order, change C in catalog number to D. Ex: -9C--DD becomes -9D--DD. Check with customer service representative to determine stock availability. ❹ See pages 5-5 for limitations on adding auxiliaries to true DC contacts. SSN9 Discount Schedule -

6 - True DC Coil Four Pole - Series Non-Reversing, Four Pole With True DC Coil, Series (Open type only) Ratings for Switching C Motors (C / C / C) Contact [] kw (5 Hz) UL/CS HP (6 Hz) Configuration, Ø Ø Main Pole V C- C- V 5V 5V 69V 5V V V V 6V 575V NO NC Catalog Number Price -9C-M / / 5 7-/ -9C-M- 68-9C-M- 68 -C-M / 7-/ -C-M- -C-M- -6C-M C-M- 5-6C-M- 5 -C-M / 5 5 -C-M- 6 -C-M C-M / C-M- 85-9C contactor (typical) Description: True DC coils have low inrush which allows the use of smaller power supplies. See page 6 for more information. DC and C coils are not interchangeable. -9C C contactors have increased dimensions to accommodate true DC coils. Coil Codes ➊ DC Coil Codes D D ➋ 8D D D Voltage V V 8V V V Coil Terminal Position ll contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering contactors with reversed coils. ll contactors come with reversible coils. SSN9 ➊ Other voltages available, see page 6. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➋ Surge suppressor coil with integrated diode available. Order coil code DD and add $ to list price. To order, change C in catalog number to D. Ex: -9C-M-DD becomes -9D-M-DD. Discount Schedule -

7 - Low Consumption Electronic DC Coil Three Pole - Series Non-Reversing, Three Pole With Electronic VDC Coil, Series (Open type only) ➊➋➌ Ratings for Switching C Motors (C / C / C) [] kw (5 Hz) UL/CS HP (6 Hz) ➊ Ø Ø V/ C- C- V 5V 5V 69V 5V V V V 6V 575V NO NC 9 / / 5 7-/ / 7-/ / / / / 5 uxiliary Contacts per Catalog Number -9E--E -9E--E -E--E -E--E -6E--E -6E--E -E--E -E--E -E--E -E--E -E--E -7E--E -7E--E -7E--E -E--E -E--E -E--E Price E--E contactor -7E--E contactor Description Low Consumption Electronic DC coils have extremely low inrush which allows the use of smaller power supplies. -9E E has internal surge suppression. See page 78 for more information. This new design results in: Lighter, lower depth More energy efficient contactors Easier wiring Uniform panel appearance. pplications Direct control from PLC: The low power consumption contactor designed to control motors and other loads is especially aligned to the specific requirement of electronic control circuits. The low power consumption of.5 W/6 m allows direct control through PLC s without the need for interposing relays. Power dissipation is greatly reduced limiting the heat effect in control panels. Coil Terminal Position ll contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering contactors with reversed coils. ll contactors come with reversible coils. ➊ C Resistive Ratings and UL/CS Continuous Current Ratings may be increased by the use of Lug Kits or Paralleling Links. See ccessories section for applicable information. ➋ DC and C coils are not interchangeable. -9E E are only available in VDC. ➌ See pages 5-5 for limitations on adding auxiliaries to Electronic DC Coil contacts. SSN9 Discount Schedule -

8 - Low Consumption Electronic DC Coil Four Pole - Series Non-Reversing, Four Pole With Electronic VDC Coil, Series (Open type only) ➊➋ Ratings for Switching C Motors (C / C / C) Contact [] kw (5 Hz) UL/CS HP (6 Hz) Configuration, Ø Ø Main Pole V C- C- V 5V 5V 69V 5V V V V 6V 575V NO NC Catalog Number 9 / / 5 7-/ / 7-/ -9E-M-E -9E-M-E -9E-M-E -E-M-E -E-M-E -E-M-E Price E-M-E contactor E-M-E -6E-M-E -6E-M-E / 5 5 -E-M-E -E-M-E -E-M-E E-M-E / E-M-E 55 9 Description Low Consumption Electronic DC coils have extremely low inrush which allows the use of smaller power supplies. -9E E has internal surge suppression. See page 78 for more information. This new design results in: Lighter, lower depth More energy efficient contactors Easier wiring Uniform panel appearance. pplications Direct control from PLC: The low power consumption contactor designed to control motors and other loads is especially aligned to the specific requirement of electronic control circuits. The low power consumption of.5 W/6 m allows direct control through PLC s without the need for interposing relays. Power dissipation is greatly reduced limiting the heat effect in control panels. Coil Terminal Position ll contactors are stocked and delivered with the coil terminals located on the line side (top) of the contactor. This is the typical configuration when using the contactor with an overload relay. When the contactor is used with the KT7 Motor Circuit Controller, the coil must be reversed, so that the coil terminals are located at the load side (bottom) of the contactor. coils can easily be reversed in the field, however, they are also available for order with the coils reversed from the factory. Contact your Sprecher+Schuh representative for more information about ordering contactors with reversed coils. ll contactors come with reversible coils. SSN9 ➊ DC and C coils are not interchangeable. -9E E are only available in VDC. ➋ See pages 5-5 for limitations on adding auxiliaries to Electronic DC Coil contacts. Discount Schedule - 5

9 - Two Winding DC Coil Three Pole - Series Non-Reversing, Three Pole With Two Winding DC Coil, Series (Open type only) ➊➋➌ Ratings for Switching C Motors (C / C / C) uxiliary Contacts per [] kw (5 Hz) UL/CS HP (6 Hz) V/ Ø Ø ➊➋➌ C- C- V 5V 5V 69V 5V V V V 6V 575V NO NC Catalog Number Price 9 / / 5 7-/ / 7-/ / / / / / Y-D- -9Y-D- -9Y-D- -Y-D- -Y-D- 5 -Y-D- -6Y-D- -6Y-D- 78-6Y-D- -Y-D- -Y-D- 5 -Y-D- -Y-E- -Y-E- 5-7Y-E- -7Y-E- -Y-E- -Y-E- 6-6D D D D-- 5-7D D D D D-- 6-6Y contactor (typical) Description: with two winding DC coils have very low hold-in values and share the same dimensions with C contactors. See page 6 for more information. See page 89 for dimensional information. NOTE: Items in gray are special order. -9Y Y with Two Winding, -lead Coils Coil Codes ➍➎➏ DC Coil Code Voltage DD V DD V ) The two winding, -lead DC coil consists of a pick-up winding and a hold-in winding. ) The contactor pulls-in through the lower resistance pick-up winding and holds-in through a higher resistance holding winding. ) The pick-up winding is not designed for continuous operation and must be disconnected by the special late opening auxiliary contact immediately after the contactor pulls-in and seals. ) Z is a built-in bidirectional diode (surge suppressor) for voltages up to V, which is located below the coil terminal cover at &. For coil voltages /5V, an externally mounted CRD7-5 must be used for surge suppression. Ordering Instruct ions ➊ -9Y Y-D(D) contactors are supplied with one NO auxiliary in the base. - 9Y Y-D contactors are supplied with one NC auxiliary in the base. ➋ ll -9Y Y contactors are supplied with an extra right side mounted block, that includes one auxiliary available for customer use, in addition to a 5ms late opening auxiliary contact for transition from pick-up winding to hold-in winding. ➌ -6D -85D have an internal auxiliary contact to transition from the start winding to the run winding. ➍ Coils include an integrated diode surge suppressor. ➎ Other coil voltages are available, see page 6. Contact your Sprecher + Schuh Sales Representative to determine which coil voltages may be stocked. Non-standard coil voltages (non-stock) must be ordered and installed separately as renewal parts. ➏ The coil codes shown are the most commonly stocked items. Contact your Sprecher + Schuh representative to determine if other voltages, i.e.., DD, 8DD, DD are on-hand or can be specially ordered in quantities. SSN9 6 Discount Schedule -

10 - Two Winding DC Coil Four Pole - Series Non-Reversing, Four Pole With Two Winding DC Coil, Series (Open type only) ➊➋ [] Ratings for Switching C Motors (C / C / C) Contact uxiliary Contacts Per kw (5 Hz) UL/CS HP (6 Hz) Configuration Main Pole 5V Ø Ø ➊ C- C- V V 5V 69V 5V V V V 6V 575V NO NC NO NC Catalog Number Price -9Y-M-D- -9Y-M-D- 9 / -/ 5 7-/ -9Y-M-D- -9Y-M-D- -9Y-M-D- -9Y-M-D- -Y-M-D- 55 -Y-M-D / 7-/ -Y-M-D- 68 -Y-M-D- 68 -Y-M-D- 68 -Y-M-D- 68-6Y-M-D- 78-6Y-M-D Y-M-D- 9-6Y-M-D- 9-6Y-M-D- 9-6Y-M-D- 9 -Y-M-D- 5 -Y-M-D / 5 5 -Y-M-D- 7 -Y-M-D- 7 -Y-M-D- 7 -Y-M-D / D-M- 78 Description: See opposite page / D-M- 78 NOTE: Items in gray are special order. -9Y Y with Two Winding, -lead Coils Coil Codes ➌➍ DC Coil Code Voltage DD V ) The two winding, -lead DC coil consists of a pick-up winding and a hold-in winding. ) The contactor pulls-in through the lower resistance pick-up winding and holds-in through a higher resistance holding winding. ) The pick-up winding is not designed for continuous operation and must be disconnected by the special late opening auxiliary contact immediately after the contactor pulls-in and seals. ) Z is a built-in bidirectional diode (surge suppressor) for voltages up to V, which is located below the coil terminal cover at &. For coil voltages /5V, an externally mounted CRD7-5 must be used for surge suppression. DD V SSN9 ➊ ll -9Y Y contactors are supplied with an extra right side mounted block, that includes one auxiliary available for customer use, in addition to a 5ms late opening auxiliary contact for transition from pick-up winding to hold-in winding. ➋ -9D...contactors have an internal auxiliary contact to transition from the start winding to the run winding. ➌ Coils include an integrated diode surge suppressor. ➍ Other coil voltages are available, see page 6. Contact your Sprecher + Schuh Sales Representative to determine which voltage may be stocked. Non-standard coil voltages (non-stocked) must be ordered and installed separately as renewal parts. Discount Schedule - 7

11 , C Coil Reversing Three Pole - Series CU7 Reversing, Three Pole With C Coil, Series CU7 (Open type only) Ratings for Switching C Motors (C / C / C) uxiliary [] kw (5 Hz) UL/CS HP (6 Hz) Contacts per Ø Ø C- C- V V 5V 5V 69V 5V V V V 6V 575V NO NC ➌ Catalog Number Price 9 / / 5 7-/ CU / 7-/ CU CU7-9-- reversing contactor CU / 5 5 CU / / / / CU ➍ CU CU ➍ CU CU ➍ CU CU ➍ CU CU7-7-- ➍ CU CU ➍ CU CU7--- reversing contactor Includes: Line side coil terminations Mechanical and electrical Interlock ➌ Reversing power wiring ➊ (using Power Wiring Kit Cat.# CUT7-PW ) Control wiring available; see footnote ➋ Coil Codes ➎ C Coil Voltage Range Code 5 Hz 6 Hz Z V V V V 8 ~ 8V W ~ 8V - V V V 77 V 77V 8 8V-V V 8 V 8V 6 55V 6V ➊ For Reversing without power wiring add suffix -LW to catalog number and deduct the following amount: CU7-9 deduct $ CU7-7 deduct $ CU7- deduct $ CU without power wiring not available Ex: CU7-9-- becomes CU LW. ➋ For control wiring, add suffix -CW to catalog number and add $. Example: CU7-9-- becomes CU CW. ➌ The NC auxiliary contacts are supplied as part of the mechanical interlock (Cat.# CM7-) and are used to electrically interlock the contactors. ➍ The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliary contacts must be special ordered. Contact your Sprecher+Schuh representative. ➎ Other voltages available, see page 6. Nonstandard coil voltages not listed here must be ordered and installed separately as renewal parts. SSN9 8 Discount Schedule -

12 , DC Coil Reversing Three Pole - Series CU7 Reversing, Three Pole With DC Coil, Series CU7 (Open type only) Ratings for Switching C Motors (C / C / C) uxiliary Contacts per [] kw (5 Hz) UL/CS HP (6 Hz) Ø Ø V C- C- V 5V 5V 69V 5V V V V 6V 575V NO NC ➌ Catalog Number Price 9 / / 5 7-/ CU7-9C / 7-/ CU7-C-- 95 CU7-9C- reversing contactor CU7-6C / 5 5 CU7-C / / / / CU7-C-- 69 ➍ CU7-C-- 76 CU7-7C-- 89 ➍ CU7-7C-- 9 CU7-C-- 98 ➍ CU7-C-- 98 CU7-6D-- 5 ➍ CU7-6D-- 59 CU7-7D-- ➍ CU7-7D-- 8 CU7-85D-- 6 ➍ CU7-85D-- NOTE: DC and C coils are not interchangeable. -9C C contactors have increased dimensions to accommodate true DC coils. -6D 85D contactors have a two winding, -lead coil with builtin late break auxiliary contact and coil suppression. Refer to page for dimensions. CU7-C- reversing contactor Includes: DC operating mechanism Line side coil terminations Mechanical and electrical Interlock ➌ Reversing power wiring ➊ (using Power Wiring Kit Cat.# CUT7-PW ) Control wiring available; see footnote ➋ SSN9 Coil Codes ➎➏ CU7-9C...C DC Coil Code CU7-6D...85D DC Coil Code Voltage D DD V D ➐ DD V 8D 8DD 8V D DD V D DD V ➊ For Reversing without power wiring add suffix -LW to catalog number and deduct the following amount: CU7-9C C deduct $ CU7-C 7C deduct $ CU7-C deduct $ CU7-6D 85D without power wiring not available Ex: CU7-9-- becomes CU LW. ➋ For control wiring, add suffix -CW to catalog number and add $. Example: CU7-9-- becomes CU CW. ➌ The NC auxiliary contacts are supplied as part of the mechanical interlock (Cat.# CM7-) and are used to electrically interlock the contactors. ➍ The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliary contacts must be special ordered. Contact your Sprecher+Schuh representative. ➎ Other voltages available, see page 6. Non-standard coil voltages not listed here must be ordered and installed separately as renewal parts. ➏ Coils for CU7-6D 85D reversing contactors include an integrated diode surge suppressor. ➐ Surge suppressor coil with integrated diode available. Order coil code DD and add $8 to list price ($ x two contactors). To order, change C in catalog number to D. Ex: CU7-9C--D becomes CU7-9D--DD. Discount Schedule - 9

13 , Low Consumption Electronic DC Coil Reversing Three Pole - Series CU7 Reversing, Three Pole With Electronic VDC Coil, Series CU7 (Open type only) ➎➏ Ratings for Switching C Motors (C / C / C) uxiliary [] kw (5 Hz) UL/CS HP (6 Hz) Contacts per Ø Ø V C- C- V 5V 5V 69V 5V V V V 6V 575V NO NC ➌ Catalog Number Price 9 / / 5 7-/ CU7-9E--E / 7-/ CU7-E--E 597 CU7-9E--E reversing contactor CU7-6E--E / 5 5 CU7-E--E / / / 5 CU7-E--E 78 ➍ CU7-E--E 8 CU7-7E--E 97 ➍ CU7-7E--E 8 CU7-E--E 5 ➍ CU7-E--E 9 CU7-7E--E reversing contactor Description Low Consumption Electronic DC coils have extremely low inrush which allows the use of smaller power supplies. -9E E has internal surge suppression. See page 78 for more information. This new design results in: Lighter, lower depth More energy efficient contactors Easier wiring Uniform panel appearance. pplications Direct control from PLC: The low power consumption contactor designed to control motors and other loads is especially aligned to the specific requirement of electronic control circuits. The low power consumption of.5 W/6 m allows direct control through PLC s without the need for interposing relays. Power dissipation is greatly reduced limiting the heat effect in control panels. Includes: Line side coil terminations Mechanical and electrical Interlock ➌ Reversing power wiring ➊ (using Power Wiring Kit Cat.# CUT7-PW ) Control wiring available; see footnote ➋ CU7-9E E has internal surge suppression. ➊ For Reversing without power wiring add suffix -LW to catalog number and deduct the following amount: CU7-9E E deduct $ CU7-E 7E deduct $ Ex: CU7-9E--E becomes CU7-9E--E-LW. ➋ For control wiring, add suffix -CW to catalog number and add $. Example: CU7-9E--E becomes CU7-9E--E-CW. ➌ The NC auxiliary contacts are supplied as part of the mechanical interlock (Cat.# CM7-) and are used to electrically interlock the contactors. ➍ The NO auxiliary contacts supplied are side mounted. Top mount NO auxiliary contacts must be special ordered. Contact your Sprecher+Schuh representative. ➎ DC and C coils are not interchangeable. -9E E are only available in VDC. ➏ See pages 5-5 for limitations on adding auxiliaries to Electronic DC Coil contacts. SSN9 Discount Schedule -

Series CA7 Contactors

Series CA7 Contactors C7 Series C7 Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

onlinecomponents.com

onlinecomponents.com ccessories Field Installable Top (Front) Mount uxiliary Contact Blocks ➊ Contact Block NO NC Top mount auxiliary contact blocks snap-on to the top (front) of any contactor 4-pole auxiliary 2-pole auxiliary

More information

Series CA9 Contactors

Series CA9 Contactors Series C9 Contactors Sprecher + Schuh s C9 contactor line combines the simple function of our popular C7 series with the rugged performance demanded in this wide horsepower range. C9 contactors offer a

More information

0 1 CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA-20 27

0 1 CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA CA7 all CA7-PA-20 27 ccessories Field Installable C7 Top (Front) Mount uxiliary Contact Blocks Contact Block NO NC 0 2 Contact rrangement 5161 5262 with... Standard Contacts Catalog Number Price Bifurcated Contacts Catalog

More information

Large Frame IEC Contactors

Large Frame IEC Contactors Large Frame IEC Contactors Bulletin 100-E PUBLIC Copyright 2017 Rockwell Automation, Inc. All Rights Reserved. 1 Changing Applications for Contactors There are fewer and fewer traditional large motor starting

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies Contactor Industrial Controls Product Catalog 07 Section c o n t e n t s Section Overview / - /5 Product Overview /6 - /7 Contactors 3RT0, 3-pole to 95 /8 3RT0, 3-pole to 500 /9 3RT, 3-pole Vacuum to 500

More information

Allen-Bradley Bulletin 100 Contactors

Allen-Bradley Bulletin 100 Contactors Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

IEC Power Control Contactors and Contactor Assemblies

IEC Power Control Contactors and Contactor Assemblies IEC Power Control Contactors and Contactor ssemblies Contents Pages Contents Pages Section Overview......................... / - /5 Product Overview......................... /6 - /7 Contactors 3RT0 / 3RT0,

More information

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters

low voltage GLOBAL CATALOGUE RANGE Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters CTLOGUE GLOBL RNGE 2. Motor Control Contactors - Thermal Overload Relay s - Manual Motor Starters 2. 2. Product Overview. 2.2 Overload Relay Setting Range 2. - 2.8 Product Specifications 2.9-2. Contactor

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies RT contactors, size S00 The product range at a glance The new generation is a complete, modular system family, logically designed right down to the last detail, from the basic units to the accessories.

More information

Allen-Bradley Drives

Allen-Bradley Drives Overview/Product Selection Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

Control, Timing + Ice Cube Relays

Control, Timing + Ice Cube Relays ... 2 Technical Information... 14 CS8... 18 Technical Information... 21 RZ7-FS Electronic... 24 Technical Information... 34 RZ7-FE Electronic... 36 Technical Information... 42 Relpol Ice Cube Relays R2/R4

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Sprecher + Schuh 15910 International Plaza Drive Houston, TX 770 U.S.A. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,

More information

C 2 5 D N A A A

C 2 5 D N A A A Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

IEC Contactors. Auxiliary Contact Blocks GENERAL

IEC Contactors. Auxiliary Contact Blocks GENERAL IEC Contactors Auxiliary Contact Blocks GENERAL Description 3RH19 Auxiliary contact blocks The 3RH19 auxiliary contact blocks are available in 1, 2, 3 and 4-pole front mount versions and 2-pole side mount

More information

XT IEC Power Control Contactors, Starters and Overload Relays

XT IEC Power Control Contactors, Starters and Overload Relays May 00 Product Family Overview 9 Contents Features and Benefits Description Page Contactors and Starters Catalog Number Selection................. Non-reversing Contactors.... Reversing Contactors........

More information

RW-E. Overloads. Solid-State Overload Relays. Standard Features

RW-E. Overloads. Solid-State Overload Relays. Standard Features RW-E The new RW_E Solid State Overload relays are developed with cutting edge technology according to the most demanding standards worldwide. With its wide current/mp setting; the RW_E OL Relay can be

More information

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ (KS7-C0C4R) Discount Schedule F-1 KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG 551 Q4 ~

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell utomation Inc. 101 South nd Street Milwaukee, WI 504 U.S.. EU Declaration of Conformity IEC Contactors, Safety Contactors, Reversing Contactors,

More information

3RT, 3TB, 3TF Contactors for Switching Motors

3RT, 3TB, 3TF Contactors for Switching Motors RT, TB, TF Contactors for Switching Motors Overview RT contactors and coupling relays Size S00 with mountable accessories The SIRIUS generation of controls is a complete, modular system family, logically

More information

EC Declaration of Conformity

EC Declaration of Conformity The undersigned, representing the manufacturer Rockwell Automation uchserstr. 7 CH-5000 Aarau, Switzerland herewith declare that the Products Product identification (brand and catalogue number/part number):

More information

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R)

Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐. Non-Metallic Type 1/12K/IP66 Enclosure (KS7-C0C4R) KWIKstarter/CX7 CX7 Non-Reversing Combination Controller, AC Enclosed Non-Reversing Combination Controller, AC Operation - Type 1/12K/IP66 ➏➐ Catalog Number ➍➏➑➒ ~ ~ ~ ~ 0.10 0.16 2.1 1 CX7-9-10- -AS0.16A-A10-PG

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

Technical Information

Technical Information Technical Information Short Circuit Ratings KT7 Assembly Application Rating Chart (Ratings are dependent on type of application) ➊ Rating Index Assembly Components Manual Controller or Group Installation

More information

29 $ Manual Motor Starters FREESHIPPING. MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame.

29 $ Manual Motor Starters FREESHIPPING.  MOTOR CONTROLS 25. Features: MMS-32H Frame. MMS-63H Frame. www.factorymation.com/motorcontrols MOTOR CONTROLS 25 Manual Motor Starters High interrupt capacity Din rail and surface mounting Lockable handle (OFF position) IP20 finger safe terminals Class 10 thermal

More information

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks

Mini Contactors. Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks. Interface Contactor Relays. Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors Mini Contactor Relays 4-pole 20 Auxiliary Contact Blocks Interface Contactor Relays Mini Contactors 22 Auxiliary Contact Blocks Mini Contactors With Fast On Tab Connectors 24 Mini Contactors

More information

Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. Located on page Max. Hp Rating Fuse Clip Type 3R/4/12

Heater Elements Starters with eutectic alloy overload relays require 3 heater elements. Located on page Max. Hp Rating Fuse Clip Type 3R/4/12 Bulletin NEM Combination Reversing Starters Product Selection Disconnect Type (Fusible with Class R Fuse Clips) (Non-Fusible) Bulletin NEM starter sizes Overload relays: Eutectic supplied as standard,

More information

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors.

Table 1. IEC Power Control Devices. Type Description Cost Electrical Operations. Soft starters or drives that gradually start and stop motors. IEC Power Control Devices Training Manual XT Training Module New Information March 08 Contents Description Page Overview..................... Contactors................... Overload Relays (Bimetal).......

More information

Crane Control Contactors and Relays

Crane Control Contactors and Relays October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver

More information

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017

3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017 3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data

More information

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information... Ice Cube Relays R2/R4 Plug-in Power Relays... 58 Technical Information... 63 R15 Plug-in Power Relays... 68 Technical Information... 72 RUC Plug-in Power Relays... 76 Technical Information... 79 RY2 Plug-in

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters

TeSys contactors Component parts for assembling reversing contactors for motor control or low speed - high speed starters Component parts for assembling reversing contactors for motor control or low speed - high speed starters For 3-pole motor reversing contactors using identical contactors 810373 Contactors with screw clamp

More information

3 Pole Contactors with AC operating coils

3 Pole Contactors with AC operating coils 1 3 Pole Contactors with AC operating coils Characteristics General Characteristics Switching Current 9A ~ Rated insulation voltage (Ui) (Conforming to IEC 158-1) V 750 IEC 60947-4 V 1000 Conforming to

More information

Bulletin 700-P, 700DC-P Industrial Relays

Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700 P Direct Drive Convertible Contact Cartridge Relays NEMA and IEC ratings 600V maximum AC/DC Accessories for field installation: contact cartridges,

More information

Control & Timing Relays

Control & Timing Relays Control & Timing Relays CS7 Industrial Control Relays... 2 Technical Information & Dimensions (Online)... 13 CS8 Industrial Control Relays... 17 Technical Information & Dimensions (Online)... 20 RZ7-FS

More information

K-Line Mini - Contactors, Overload Relays and Accessories

K-Line Mini - Contactors, Overload Relays and Accessories K-Line Mini - Contactors, Overload Relays and Accessories Class 8502 CONTENTS Description...................................................... Page General Information...............................................

More information

Exercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION

Exercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION Exercise 1-4 Contactors and Control Relays EXERCISE OBJECTIVE Identify the characteristics of control relays and contactors. DISCUSSION OUTLINE The Discussion of this exercise covers the following points:

More information

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview

FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview FAZ Supplementary Protectors, FAZ Miniature Circuit Breakers, P2 Disconnect Switches Overview Supplementary Protectors / Miniature Circuit Breakers Page System overview 10/003 10/001 Supplementary protectors

More information

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts

TeSys D contactors. Selection guide. All types of control system. Rated operational voltage. Rated operational power in AC-3. Auxiliary contacts Selection guide TeSys D contactors Applications All types of control system Rated operational current le max AC- (Ue y 0 V) 9 A A A A A A le AC- (q y 0 C) 0/ A / A /0 A 0 A Rated operational voltage 90

More information

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100

CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 MKING MODERN LIVING POSSIBLE Technical brochure CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M, CTI 45MB, CTI 100 Circuit breakers for short circuit- and overload protection of motor applications

More information

Motor Control Products Selection Guide

Motor Control Products Selection Guide MKING MODERN LIVING POSSIBLE Motor Control Products Selection Guide Contactors, Relays, and Circuit Breakers www.danfoss.com/ia c o n t e n t s Minicontactors CI 5 Thermal Overload Relays TI 9C for Minicontactors

More information

TeSys contactors From 115 to 2750 A

TeSys contactors From 115 to 2750 A Selection guide From to 0 A Applications Control of all types of motor for standard or severe duty applications Control of resistive, inductive and capacitive circuits: heating, lighting, cos j rectification,

More information

Overloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D

Overloads. RW Series Catalog Number Sequence. RW Series - Bi-Metallic Thermal Overload Relays. Standard Features 3 - RW 27-1D Circuit Protection Disconnect Switches Thermal Overload Relays n extended operational service life is one of the main features you can find in RW overload relays. WEG s RW Thermal Overload Relays are designed

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals

NF44E-.. / NFZ44E-.. Contactor Relays AC / DC Operated - with Screw Terminals Technical Datasheet 1SBC1010D0201 28/03/11 NFE-.. / NFZE-.. Contactor Relays AC / DC Operated - with Screw Terminals NF(Z) contactor relays are used for switching auxiliary and control circuits. NF(Z)

More information

New Solutions. for AC Motor Starters

New Solutions. for AC Motor Starters ADAPTABILITY RELIABILITY CREATIVITY New Solutions for AC Motor Starters Featuring : Electronic Centrifugal Switches for Capacitor Start (Capacitor Run) Motors / Digital Motor Starters for Three Phase Bidirectional

More information

Contactors and Contactor Assemblies

Contactors and Contactor Assemblies SIRIUS Contactors and Contactor Assemblies Application WYE-delta starting can only be used either if the motor normally operates in a d (delta) connection or starts softly or if the load torque during

More information

Motor protection relays

Motor protection relays Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30

More information

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay Bulletin -P Heavy-Duty Industrial s Product Selection DC-Operated s Rail Mount DIN Rail Mount Cat. No. Cat. No. -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD DC Coil

More information

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III

Quantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North

More information

3.7. Control Relays and Timers.

3.7. Control Relays and Timers. Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................

More information

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................

More information

Solid-State Contactors

Solid-State Contactors Solid-state contactors for switching motors The solid-state contactors for switching motors are intended for frequently switching on and off three-phase current operating mechanisms up to 7.5 kw and reversing

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell Automation Inc. 101 South nd Street Milwaukee, WI 5304 U.S.A. EU Declaration of Conformity IEC Contactors, Reversing Contactors and Accessories Name

More information

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog

Issued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic

More information

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators

SmartWire-DT In panel and on machine wiring solutions. Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT In panel and on machine wiring solutions Revolutionizing in-panel control wiring and on-machine connection of sensors and actuators SmartWire-DT Changing the way panels... Reduce cost throughout

More information

Switch Disconnectors, Main and EMERGENCY-STOP Switches

Switch Disconnectors, Main and EMERGENCY-STOP Switches General data Overview Siemens G 2010 1 2 3 NSE0_01931b 4 5 6 7 1 uxiliary switch (3SB for 3K; 3KX for 3KE) 2 IP20 terminal cover (Operator side) 3 3K switch disconnector 4 rcing contacts (only for 3KE)

More information

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series

OVERLOAD RELAYS POWER & ACTUATION PROVEN. series POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be

More information

DIN Molded Cable Assemblies

DIN Molded Cable Assemblies DIN 43650 Telephone (973) 586-500 FAX (973) 596-590 DIN 43650 8mm For Solenoid Valve Applications Black PVC Cable & Connector DUAL JUMPED GROUND PINS Molded cable assemblies can be mounted with cable exiting

More information

High Voltage Contactors

High Voltage Contactors High Voltage Contactors Contents Page 1.0. Application...3 2.0. Power Rating...3 3.0. Device Data...4 3.1. Electronic Contactor Type ZH 767E / 767F... 4 3.2. Contactor Type ZH 829...5 3.3. Contactor ZH

More information

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors

MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors B Curve NC100H Supplementary Protectors Rating 1P 2P 3P 4P 80 MG27164 MG27175 MG27186 MG27197 MULTI 9 System Catalog UL Recognized NC100H Supplementary Protectors C Curve NC100H Supplementary Protectors

More information

EU Declaration of Conformity

EU Declaration of Conformity Product: Name and address of the manufacturer: Rockwell utomation Inc. 101 South nd Street Milwaukee, WI 504 U.S.. EU Declaration of Conformity IEC Control Relays, Safety Control Relays and ccessories

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

Bulletin 700-P, 700DC-P Industrial Relays

Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700-P, 700DC-P Industrial Relays Adder Decks Description No. of N.O. Contacts Continuous Carrying Current [A] Arrangement Second Deck (0-pole) 0 700-PB00 Second Deck 700-PB40 Second Deck (4-pole)

More information

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser

Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser Power Energy Analyser & Logic Controller Maximum Demand Load Shed Controller 2nd - 40th Voltage & Current Harmonic Analyser 4 Target Max. Demand (MD) Load Shed Controller Up to 64 loads may be shed to

More information

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1)

Mini contactors. K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. a.c. control contactors (1) K 3-pole contactors for motor control, 6 and 9 A Utilisation category AC-3 Control circuit : a.c. c LC-K060ii a.c. control contactors () Standard power ratings Rated Type of Instantaneous Basic reference.

More information

Table of Specifications

Table of Specifications Table of Specifications Midi-Contactors 3-Pole Magnetic Contactors Terminal type CC9 CC12 CC18 CC22 CC32 CC40 Screw Only Screw Only GUA1, GUA2, GUA4 GUA-1 GUA-2, GUA-4 GUA-1 GUA-2, GUA-4 GT Type Thermal

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

AZ420 MINIATURE GENERAL PURPOSE RELAY

AZ420 MINIATURE GENERAL PURPOSE RELAY MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 100 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available

More information

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton

IEC Type Industrial Control Relays; TeSys D-Line, K-Line, and SK-Line K-Line Ordering Informaiton K-Line Ordering Informaiton K-Line Ordering Information Control Relays - Mounting on 35 mm DIN3 track or 4 screw direct mounting. - Screws in open ready-to-tighten position. Control Circuit Contact Configuration

More information

Application Note. Common Bussing AC Drives. For 584SV and 620 series drives APP-AC-02

Application Note. Common Bussing AC Drives. For 584SV and 620 series drives APP-AC-02 Application Common Bussing AC Drives APP-AC-02 For 584SV and 620 series drives APP-AC-02 2004 SSD Drives inc. 9225 Forsyth Park Drive, Charlotte, NC 28273 Page of 6 Introduction On occasion, one or more

More information

Jockey Pump Controllers

Jockey Pump Controllers BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single

More information

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure

MAKING MODERN LIVING POSSIBLE. CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M Technical brochure MKING MODERN LIVING POSSIBLE CI-TI Contactors and Motor Starters Circuit Breakers CTI 25M - 100 Technical brochure 2 IC.PD.C00.5.02-520B3595 Danfoss /S (R-MC/mr) 08-2009 Contents Page Circuit Breakers/

More information

Bulletin 194R Fused and Non-Fused Disconnects Product Selection

Bulletin 194R Fused and Non-Fused Disconnects Product Selection Product Selection 4th Pole Modules Maximum Hp Ratings Rated 1-Phase (60 Hz) -Phase (60 Hz) DC Current [A] 10V 40V 40V 480V V 1V 0V Ref. Cat. No. Non-d 0 7. 1 0 A 194R-0-NN 60 1 0 40 B 194R-60-NN UL Class

More information

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A

FUSERBLOC UL Fusible disconnect switches UL and CSA from 30 to 800 A Fuse protection The solution for > Motor on-load disconnect > Protection of industrial cabinet > Electrical distribution ul_004_a Strong points fuser-ul_006_a Function FUSERBLOC UL fusible disconnect switches

More information

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V

Product Information SIMATIC S Digital Output Module SM 322; DO 16 UC24/48 V Product Information SIMATIC S7-300 Digital Output Module SM 322; DO 16 UC24/48 V X 2 as of Version 3 4 New Digital Output Module Available The S7-300 Digital Output Module SM 322; DO 16 UC24/48 V has been

More information

Jockey Pump Controllers

Jockey Pump Controllers BR081001EN Microprocessor Based with Color Touchscreen Product Description ACROSS THE LINE Controllers operate across-the-line. Full voltage is applied to the motor for starting by the use of a single

More information

Description Page Number PM AC Relays PM DC Relays

Description Page Number PM AC Relays PM DC Relays Index Relays Description Page Number General Information... PM AC Relays PM Convertible, PMA, PMF, AC Relays... PM Latching, PML, PMAL, AC Relays... 5 Pole Arrangement, Diagrams, PM, PMA, PMF... 6 Dimensional

More information

Revolutionizing control wiring

Revolutionizing control wiring SmartWire-DT Panel Wiring Solutions Revolutionizing control wiring 797-6925 Fax: (215) 221-1201 www.royalelectric.com SmartWire-DT Changing the way panels are wired. Reduce cost throughout the value chain.

More information

Safety. Detection. Control. MAGNUS RFID ENG - REV

Safety. Detection. Control. MAGNUS RFID ENG - REV 03 2017 1 Next generation RFID safety sensor 03 2017 2 03 2017 3 Next generation sensors for machine safety RFID safety sensors PL e, SIL 3 The application of Magnus RFID sensors can be extremely wide

More information

Electrical Demand Specification (Reference SOP: )

Electrical Demand Specification (Reference SOP: ) Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3

More information

Latching, Sequence and Impulse Relays Application Data

Latching, Sequence and Impulse Relays Application Data Latching, Sequence and Impulse Relays Application Data Energy Conservation Relays In many applications it is important for the customer to conserve electrical energy. One approach to energy conservation

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

Relay Contact Output Modules

Relay Contact Output Modules Relay contact output modules offer dry circuits, that is, circuits without leakage current. Leakage currents are present on solid-state outputs; these currents are capable of energizing highly sensitive

More information

SafeC S to MSR127 Conversion

SafeC S to MSR127 Conversion Application Note SafeC S to MSR127 Conversion IMPORTANT: A risk assessment must be completed to assure that all tasks and hazards are considered and confirm that the example circuit will provide adequate

More information

RADIAN TPCMQ24 SERIES 24VDC Input 1RU Rack-Mount DC-DC Front-Ends 1000W and 1200W 1000W INDUSTRIES & APPLICATIONS

RADIAN TPCMQ24 SERIES 24VDC Input 1RU Rack-Mount DC-DC Front-Ends 1000W and 1200W 1000W INDUSTRIES & APPLICATIONS RADIAN TPCMQ24 SERIES 24VDC Input 1RU Rack-Mount DC-DC Front-Ends 48DC @ 1000W and 1200W 54.4VDC @ 1000W INDUSTRIES & APPLICATIONS FEATURES Telecom Cable Utilities Government Industrial Isolated 5V, ¼

More information

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO

Control relays. K mini-control relays. Conforming to standards IEC/EN , , NF C , VDE 0660 UL, CSA, DEMKO, NEMKO, SEMKO Characteristics Environment Conforming to standards IEC/EN 0947-1, 0947-5-1, NF C 3-140, VDE 00 Approvals UL, CSA, DEMKO, NEMKO, SEMKO Vertical axis Horizontal axis Operating position 180 Without derating

More information

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157

Expansion Unit Catalog Nos , - 152, - 153, - 154, - 156, -E157 PRODUCT DA TA SLC 150 110 Expansion Unit Catalog Nos. 1745-151, - 152, - 153, - 154, - 156, -E157 7 : The EXpdnSiQn Unit The SLC 150 expansion unit can be used with either the SLC 150 processor unit or

More information

pointofsale available at your local trade outlet

pointofsale available at your local trade outlet pointofsale available at your local trade outlet pointofsale products IP65 pushbuttons Ø22.5mm Contact rating @ 240V AC 10A Resistive (AC1), 6A (AC15) PB01C PB02C PB03C PB04C PB05C PB06C PB07C PB08C PB09C

More information

UL 489 DIN Rail Miniature Circuit Breakers

UL 489 DIN Rail Miniature Circuit Breakers UL 489 DIN Rail Miniature Circuit Breakers Product Overview................................................ 2 Product Selection................................................ 4 Accessories.....................................................

More information

Circuit Breakers Type CTI 25M, CTI 45MB

Circuit Breakers Type CTI 25M, CTI 45MB Data sheet Circuit Breakers Type CTI 25M, CTI 45MB Circuit breakers for short circuit and overload protection of motor applications cover the current range 0.1 45 A (AC-3 rating). The product range is

More information