Description Page Number PM AC Relays PM DC Relays

Size: px
Start display at page:

Download "Description Page Number PM AC Relays PM DC Relays"

Transcription

1 Index Relays Description Page Number General Information... PM AC Relays PM Convertible, PMA, PMF, AC Relays... PM Latching, PML, PMAL, AC Relays... 5 Pole Arrangement, Diagrams, PM, PMA, PMF... 6 Dimensional Data, PM, PML, PMA, PMAL, PMF... 7 PMS, Slim Jim AC Relays... 8 PMT, AC Pneumatic Timing Relays... PM Relay Parts and Modification its... PM DC Relays PM Convertible DC Relays... PML Latching DC Relays... PMT DC Pneumatic Timing Relays... Dimensional Data DC Relays... 6 Engineering Data... 7 Series 7 Relays... 8

2 PM - Relays General Information The Joslyn Clark PM Family of control relays provides flexibility, versatility and reliability. The exclusive design concept and rugged construction of the PM line offers many advantages for the disigner and builder of today's complex control panels. Features: Modular Construction -allows field additon, replacement or conversion of poles for unlimited flexibility. Uniformity of Design -simplifies engineering, installation and maintenance. Interchangeability of Parts - reduces inventory requirements. Flexibility of Application - provided by many modifications including noble metal, gold bonded, anti-weld and overlapping contacts. Convertible Poles contain one contact, either NO or NC and can be easily field converted from one to the other. Identified be WHITE operating rod. Universal Poles contain two independent isolated contacts, one NO and one NC. Identified by RED operating rod. Duplex Poles contain two independent isolated contacts, both NO. Identified by GREEN operating rod. PMS Slim Jim Relays are - /" wide. They are the smallest members of the PM Family. Available with up to contacts; they provide the reliability of heavy duty 6 Volt relays in the smallest possible space. PM Convertible Pole Relays use white rod poles and are offered with up to 8 contacts in any combination of NO and NC contacts. Relays with up to contacts using double deck bases can be supplied.

3 General Information Relays - PM Type Relays, using universal poles have up to contacts. Relays with up to contacts are available, using some convertible poles. Type PMF Relays, combining several types of poles can have up to contacts. Type PMT Pheumatic Timing Relays, these relays are available for either "on-delay" operation (time delay after energization) or "offdelay" (time delay after de-engerization). They may also be field converted from on to "off-delay" and vice versa, by merely inverting the opertaing magnet. Type PMT Time Delay relays are adjustable over a timing range from. seconds to minutes with repetitive accuracy of + %. Latch Relays are available with either white rod convertible poles or red rod universal poles. The latching unit with continous duty trip coil replaces the two pole modules directly above the relay magnet.

4 PM - Relays AC Relays Type PM Convertible, PMA Universal, PMF Duplex Type PM Relays Type PMA Relays Type PMF Relays Convertible Pole Universal Pole Duplex Pole Total Normally Normally White Operating Rod Red Operating Rod Green Operating Rod No. of Open Closed Catalog Catalog Catalog Contacts Contacts Contacts Number Price Number Price Number Price 5U * $ 8. 5U- * 6. 5U- * 6. 5U * 6. 5U- * 5. 5U- * 5. 5U- * 5. 5U *. 5UF * $. 5U- * 76. 5UF- *. 5U- * 76. 5UU * * $ 6. 5U- * 76. 5U- * U6 * 6. 5UF6 *. 5 5U6- * 96. 5UF6- * 6. 5U6- * 96. 5UF6- * U6- * 96. 5UU * * 5. 5U6- * U6-5 *. 6 5U6-6 *. 8 5U8 *. 5UF8 * U8- * 68. 5UF8- * U8- * 68. 5UF8- * U8- * 68. 5UF8- * 96. 5U8- * 68. 5UU * U8-5 * U8-6 * U8-7 * U8-8 * 9. 5UF * UF- * UF- * UF- * 58. 5UF * 66. 5UF- * UF- * UF- * UU6 * 68. 5UF * 76. 5UF- * 77. 5UF- * 77. 5UF- * 77. 5UF- * UF-5 * UU86 * _ 5UU77 * UU68 * 7. Alternate 5U * 8. Layout 5U- * 6 Alternate * Layout 5U. See notes,5 and 6 page 5 & 7 See note page 5 Use complete catalog no. replace the (*) with suffix from coil Table, (Located on Page 5)

5 AC Relays Relays - PM Latch Relays The latch unit occupies the space of two poles directly above the magnet, and provides a means of holding the relay in the energized position after the coil of the main operating magnet is de-energized. Momentarily energizing the continous duty coil of the latch unit allows the relay to return to the normal, deenergized position. Type PM Latch Relays, PML Convertible, PMAL Universal Type PML Type PMAL Convertible Pole Universal Pole Total Normally Normally White Operating Rod Red Operating Rod No. of Open Closed Catalog Catalog Contacts Contacts Contacts Number Price Number Price 5UH * $5. 5UH- * 8. 5UH- * 8. 5UH * 8. 5UH- *. 5UH- *. 5UH- *. 5UH * 8. 5UH- *. 5UH- *. 5UUH * $8. 5UH- *. 5UH- *. 6 5UH6 * UH6- * 56. 5UH6- * UH6- * 56. 5UUH *. 5UH6- * UH6-5 * UH6-6 * UUH * UUH6 * UUH55 * UUH6 * 7. Maximum of 8 contacts only on 5 hz. PMF relays with N.C. contacts have universal red rod & duplex green rod poles. Maximum of 8 contacts only on 5 hz. Price includes open type relay complete with operating coil. Latching relays include latch unit with continuous duty trip coil. Overlapping contacts are available at $. list per pair. Specify when ordering. 5 For Dimensions, refer to page 7 For modificaion its, refer to page. 6 Additional relays with alternate pole configurations available. Relay Enclosure P6E- $8. 5UB - * pole base only $ 5U8B - * 8 pole base only $ Use complete catalog number. Replace the (*) with suffix coil table. Ex. Pole Relay with V, 6Hz. coil; 5UH-76. Latch Relays are supplied with main coil and latch coil of the same voltage. For variations, consult factory. * Suffix Coil Table Hertz Volts

6 PM - Relays AC Relays Contact Arrangement Type PM Convertible Pole Relays Numbers in pole locations indicate the sequence in which normally closed poles are mounted when required. Type PMA Universal Pole Relays Numbers in pole locations indicate the sequence in which normally closed convertible poles are mounted when required. Universal Pole - Red Operating Rod Convertible Pole - White Operating Rod Type PMF Duplex Pole Relays Numbers in pole locations indicate the sequence in which Universal poles are mounted when required. Duplex Pole - Contacts, both N.O. Green Operating Rod Convertible Pole - Contact either N.O or N.C. White Operating Rod 6

7 Dimensional Data

8 PMS - Relays AC Relays AC Relays - Slim Jim Type PMS - Bulletin 75 Pole Open Arrange- Contacts Rod Type ment N.O. N.C. Description Color Cat. No. Price Convertible Pole White 5SW * $. Convertible Poles White 5SWW * 8. Duplex Pole Green 5SG * 56. Duplex Poles Green 5SGG *. Universal Pole Red 5SR * 68. Universal Poles Red 5SRR * 6. Universal Pole Red and 5SRG * 8. Duplex Pole Green Relay Enclosure P6E- $8. Approximate Dimensions In Inches Pole Symbols Represents one Convertible Pole, which includes one normally open contact. Represents one Duplex Pole, which includes two normally open contacts. Represents one Universal Pole, which includes two contacts, one normally open and one normally closed. Represents one space where a Convertible, Duplex or Universal Pole may be added. Use complete catalog number. Replace the (*) with the suffix from Coil Table. Example: Cat. No. 5SRR-76 (- Volt, 6 Hertz). Engineering Data Modification page 9 Coil Table 6Hz Voltage Suffix Separate Control -96 Separate Control Hz Voltage Suffix

9 AC Relays Relays - PMS Pole Assemblies Contacts Rod Pole it N.O. N.C. Color Description Cat. No. Price White Convertible Pole PM-A $ 6. White Convertible Pole PM-A 6. Red Universal Pole PMA- 5. Green Duplex Pole PMF- 5. Black Convertible Pole PM-A 6. Overlap Contacts Black Convertible Pole PM-A 6. Overlap Contacts White Convertible Pole PM-A 8. Anti-Weld Contacts White Convertible Pole PM-A 8. Anti-Weld Contacts Orange Overlap Contact PMA- 8. Red Universal Pole PMA- 78. Anti-Weld Contacts Green Duplex Pole PMF- 78. Anti-Weld Contacts Universal Pole Orange Overlap. Anti- PMA-. Weld Contacts Relay Bases ly Base Coil Catalog Voltage Hertz Number Price 6 5S S S S-6 5 5S-5 $ S S S-56 Approximate Dimensions In Inches NEMA Type Enclosure Price listed for relay base includes magnet coil and mounting plate, less poles. Enclose P6E- $8. NEMA Type & Enclosure Use complete catalog number. Coil Data Inrush volt-amperes (at 6 hertz) 6 Holding volt-amperes (at 6 hertz) 6 Coil Table 6Hz Voltage Suffix Separate Control -96 Separate Control Hz Voltage Suffix

10 PMT - Relays AC Time Delay Relays AC Pneumatic Time Delay Relays - Type PMT Bulletin 7 Timing Range Adjustible From. Second To Minutes - Accuracy + % Contacts Open Type Relays No. of Time Delay Instan.Aux. Universal Oper'ng Univ. Pole 6 Mode Poles N.O. N.C. N.O. N.C. Arrangement Catalog No Price Delay None None 7UP * Off $6. Delay None None 7UPD * Delay 7UPA * Off 66. Delay 7UPDA * Delay None None 7UPE * Off 78. Delay None None 7UPDE * Delay 7UPB * Off 7. Delay 7UPDB * Delay 7UPF * Off 8. Delay 7UPDF * Delay 7UPC * Off 78. Delay 7UPDC * Delay 7UPG * Off 9. Delay 7UPDG * Notes Price includes open type relay complete with timing head and operating coil. To complete Cat. No., add coil suffix. Delay - Timed interval occurs between energization of the coil and actuation of timed contact. Off Delay - Timed interval occurs betwen de-energization of the coil and actuation of timed contact. Each universal pole consists of two independent isolated contacts suitable for 6 volts at opposite polarity. 5 Relays may be converted in the field from Delay to Off Delay and vice versa, using only a screwdriver. When this conversion is made, normally open contacts become normally closed contacts and vice versa. 6 sketches showing universal pole arrangements: Letters T indicate locations of time delay poles. Letters I indicate locations of instantaneous poles. Dotted lines indicated locations where universal poles may be added. Class A relays may have two timed poles maximum. Use complete catalog number. Replace the (*) with the suffix from Coil Table. Example: Cat. No. 7UPA (- Volt, 6 Hertz). Overlapping contacts are available in the same contact block at $. per pair. Engineering Data Modification page Coil Table Enclose P6E- $8. 6Hz Voltage Suffix Separate Control -96 Separate Control Hz Voltage Suffix

11 Modification and Parts Relays - PM Modification its for Type PM Family - Catalog Description Number Price its for BUL. 75 Type PM Convertible Pole Relays Pole its (All are convertible) N.O. Non-Overlap Contacts, Closed Top PM-A $ 6. N.C. Non-Overlap Contacts, Closed Top PM-A 6. N.O. Non-Overlap Contacts, Open Top PM-A 6. N.C. Non-Overlap Contacts, Open Top PM-A 6. N.O. Non-Overlap Contacts, Open Top, Double Ended Carrier PM-5A 6. N.C. Non-Overlap Contacts, Open Top, Double Ended Carrier PM-6A 6. N.O. Overlapping Contacts, Closed Top PM-A 6. N.C. Overlapping Contacts, Closed Top PM-A 6. N.O. Overlapping Contacts, Open Top PM-A 6. N.C. Overlapping Contacts, Open Top PM-A 6. N.O. Overlapping Contacts, Open Top, Double Ended Carrier PM-5A 6. N.C. Overlapping Contacts, Open Top, Double Ended Carrier PM-6A 6. N.O. Non-Overlap Anti-Weld Contacts, Closed Top PM-A 8. N.C. Non-Overlap Anti-Weld Contacts, Closed Top PM-A 8. N.O. Non-Overlap Anti-Weld Contacts, Open Top PM-A 8. N.C. Non-Overlap Anti-Weld Contacts, Open Top PM-A 8. N.O. Non-Overlap Anti-Weld Contacts, Open Top, Double Ended Carrier PM-5 8. N.C. Non-Overlap Anti-Weld Contacts, Open Top, Double Ended Carrier PM-6 8. N.O. Non-Overlap Gold Bonded Contacts, Closed Top PM- 9. N.C. Non-Overlap Gold Bonded Contacts, Closed Top PM- 9. N.O. Non-Overlap Gold Bonded Contacts, Open Top PM- 9. N.C. Non-Overlap Gold Bonded Contacts, Open Top PM- 9. N.O. Non-Overlap Gold Bonded Contacts, Double Ended Carrier PM-5 9. N.C. Non-Overlap Gold Bonded Contacts, Double Ended Carrier PM-6 9. Adapter Plate (to add th or th pole) PM-5 8. its for BUL. 75 Type PMA Universal Pole Relays Pole it - N.O. & N.C. Non-Overlap Contacts, Closed Top PMA- 5. N.O. & N.C. Non-Overlap Anti-Weld Contacts, Closed Top PMA- 78. N.O. & N.C. Overlapping Contacts, Closed Top PMA- 8. N.O. & N.C. Overlapping Anti-Weld Contacts, Closed Top PMA-. its for BUL. 75 Type PMF Duplex-Pole Relays Pole its - N.O. Non-Overlap Contacts, Closed Top PMF- 5. N.O. Non-Overlap Anti-Weld Contacts, Closed Top PMF- 78. it for BUL. 75 Type PML or PMAL Latch Relays Latch it, with coil - Specify trip coil voltage suffix: - 76 (-v 6hz). 6 (-v 6hz), - 6 (-8v 6hz). Specify other voltages PMH- 68. its for BUL. 7 Type PMT Timing Relays Contact Operating Link for R.H. Timed Pole PMT- 8. Contact Operating Link for Instantaneous Pole PMT- 8. Contact Mounting Bracket and Arm Assembly (R.H.) PMT- 6. Contact Mounting Bracket and Arm Assembly (L.H.) PMT- 6. Renewal Parts its - Discount Schedule JC8 Renewal Parts its for BUL. 75 Type PM Convertible Pole Relays Cat. No. Price Contact Arm, Short ( Pole) with screws PM-7. Contact Arm, Long (6 Pole) with screws PM-8. Assembled Magnet and Rod (Straight-End Bracket) A-c Relays PM-9 5. Assembled Magnet and Rod (Hooked-End Bracket) A-c Relays PM- 5. Assembled Magnet and Core., & Pole D-c Relays (Includes Rod, Bracket & Contact Arm) PM-6 7. Assembled Magnet and Core, 6 & 8 Pole D-c Relays (Includes Rod, Bracket & Contact Arm) PM Renewal Parts for BUL. 7 Type PMT Timing Relays Assembled Magnet and Rod (Folio Relays) PMT-. Timing Head (without dial) (Folio Relays) PMT- 5. & JC8

12 PM - Relays DC Relays DC Relays - Type PM Bulletin 7 General Description Bulletin 7, Type PM, D-C Convertible Pole Relays feature many of the same time-proven advantages offered by the highly successful Bullentin 75 Type PM A-C Relay. For example, normally open poles are quickly and easily convertible to normally closed and vice versa. Each pole is contained in its own molded housing mounted by a single screw. Thus, each pole may be removed, installed or replaced individually without disturbing the others. The large double-break contacts are made of fine silver alloy, and are rated for both inductive and resistive loads. The contacts are designed with wipe action to assure Total Poles Open Type Number Contact Normally Normally Catalog Of Poles Arrangement Open Closed Number Price U * $8. U- * 8. U- * 8. U * 96. U- *. U- *. U- *. U *. U- * 56. U- * 56. U- * 56. U- * U6 * U6- * 6. U6- * 6. 6 U6- * 6. U6- * 6. 5 U6-5 * U6-6 * U8 * U8- * U8- * U8- * 78. U8- * U8-5 * 7. 6 U8-6 * 7. Use complete catalog number. Replace the (*) with the suffix from Coil Table. Overlapping contacts are available in the same contact block at $8 per pair Enclosures supplied separately Price addition of $ per relay. For & 6 volt coils, use coil suffix or 6. maximum reliability. For long trouble-free relay life, the D-C coil on Bullentin 7 Relays is molded with tough epoxy resin to keep out dirt and moisture, and to prevent physical damage. The magnet used is a vertical lift type with no springs that require adjustment. It is designed with pull-in characteristics that keep magnet slam to a minimum. Extra wide pressure terminals are front mounted for ready accessibility. As many as three lugs for No. wire can be connected to each terminal. Bullentin 7 Relays are available in,,,6 and 8-pole arrangements. Contact Ratings - Amps Continuous D-C Applications Ampere Interrupting Rating Resistive Load Non-Inductive Inductive Load Volts N.O. N.C. N.O. or N.C. 6 or less A-C Applications Volts Make Break UB - * pole base only $76 U8B - * 8 pole base only $78 Note: Numbers in pole locations shown in sketches indicate the sequence in which normally closed poles are mounted when required. Normally open contacts may be changed in the field to normally closed and vice versa, using only a screw driver. * Coil Table DC Voltage DC Voltage Suffix DC Voltage Suffix

13 DC Latch Relays Relays - PM DC Latch Relays - Type PML Bulletin 75 Bullentin 75, Type PML, D-C Latch Relays are identical in design, construction and dimension to the Type PML, A-C Convertible Pole Latch Relays except they incorporate the use of one "universal" pole on the relay to permit continouus application of voltage to the relay "Close" coil and latch "Trip" coil. The schematic diagram below illustrates how this is acccomplished. Up to 8 convertible poles in any combination of N.O. and N.C. contact arrangement are available for circuit use. The contracts can be readily converted in the field from N.O. to N.C. operation, and vice versa. The latch mechanism is the same rugged unit used on Type PML-A-C latch relays. Contact Ratings - Amps Continuous D-C Applications Amperes Interrupting Rating Resistive Load Non-Inductive Inductive Load Volts N.O. N.C. N.O. or N.C. 6 or less A-C Applications Volts Make Break Typical Circuit Universal Pole (it Catalog No. PMA-). Normally closed contact connected in series with relay "Close" coil. Normally open contact connected in series with relay "Trip" coil as shown below. Permits continuous application of voltage to the coil circuits. Total Poles Open Type Number Contact Normally Normally Catalog Of Poles Arrangement Open Closed Number Price 5UHD * $9. 5UHD- * 58. 5UHD- * 58. 5UHD * 58. 5UHD- * 56. 5UHD- * 56. 5UHD- * 56. 5UHD * 55. 5UHD- * UHD- * UHD- * UHD- * UHD6 * UHD6- * 7. 5UHD6- * UHD6- * 7. 5UHD6- * UHD6-5 * UHD6-6 * UHD8 * UHD8- * UHD8- * UHD8- * 8. 5UHD8- * UHD8-5 * UHD8-6 * UHD8-7 * UHD8-8 * 88. Use complete catalog number. Replace the (*) with the suffix from Coil Table. Overlapping contacts are available in the same contact block at $8 per pair Enclosures supplied separately Note: Numbers in pole locations shown in sketches indicate the sequence in which normally closed poles are mounted when required. Normally open contacts may be changed in the field to normally closed and vice versa, using only a screw driver. Price addition of $ per relay. For & 6 volt coils, use coil suffix or 6. $5 set up charge for 5 or less units. Coil Table DC Voltage DC Voltage Suffix 8 8 Relay pole connot be located here. DC Voltage Suffix 95 95

14 PMT - Relays DC Time Delay Relays DC Pneumatic Time Delay Relays - Type PMT Bulletin 7 (. seconds to minutes) Bulletin 7 D-C Time Delay Relays are identical in construction to the Bulletin 7 Timing Relays except for the use of a conventional lead operating coil rather than a tapped (-lead) coil. They feature the same accurate piston-type timing head as used on all other timing relays in the PM family. Universal poles, with two electrically isolated contacts per pole-one normally open and one normally closed-are also used. These timing relays are available for either Delay or Off Delay operation in three basic models: () with timed pole; () with one timed and one instantaneous pole or () with two timed poles. Timing range adjustable from. seconds to minutes Accuracy + % "-Delay" Operation Type Contacts Open Type Relays Oper'n No. of Time Delay Instan.Aux. Universal Plus Univ. Pole Without Dial Delay Poles N.O. N.C. N.O. N.C. Arrangement Catalog No Price Delay 7UP Off $76. Delay 7UPD Delay 7UPA Off 79. Delay 7UPDA Delay 7UPE Off 9. Delay 7UPDE "Off-Delay" Operation Coil Burden 7. watts Note: Delay - timed interval occurs between energization of the coil and actuation of timed contact. Off Delay - timed interval occurs betwen de-engerization of the coil and actuation of timed contact. Field conversion of relays from Delay to Off Delay operation, or viceversa, is not recommended because a special technique is required. Each universal pole consists of N.O. & N.C. independent isolated contacts suitable for 6 volts at opposite polarity, a-c or d-c. Letter T on relay sketches indicated location of time delay poles. Letter I on relay sketches indicates location of instaneous poles. Dotted lines indicate where universal poles may be added. Contact Ratings - Amps Continuous D-C Applications Amperes Interrupting Rating Resistive Load Non-Inductive Inductive Load Volts N.O. N.C. N.O. or N.C. 6 or less A-C Applications Volts Make Break Use complete catalog number. Replace the (*) with the suffix from Coil Table. Overlapping contacts are available in the same contact block at $8 per pair For timer with dial, specify "with dial." Add (each) $6. Price addition of $ per relay. For 95 volt coils, use coil suffix 95. $5 set up charge for 5 or less units Coil Table DC Voltage DC Voltage Suffix

15 DC Time Delay Relays DC Pneumatic Time Delay Relays - Type PMT Bulletin 7 (. seconds to minutes) Bulletin 7, Type PMT, D-C Time Delay Relays are identical in construction and size to the A-C timing relays except they incorporate a tapped (-lead) d-c operating coil and, hence, require the use of one N.C. contact in a universal pole to economize the coil (see sketches below. However, the N.O. contact in that pole remains available for customer use. Timing relays with conventional -lead coils can also be supplied. Refer to Bulletin 7-PMT. Timing Range Adjustable From. Second to Minutes - Accuracy + % Contacts Open Type Relays No. of Time Delay Instan.Aux. Universal Oper'ng Univ. Pole Without Dial Mode Poles N.O. N.C. N.O. N.C. Arrangement Catalog No Price Delay None None 7UP-DC * Off $76. Delay None None 7UPD-DC * Delay 7UPA-DC * Off 79. Delay 7UPDA-DC * Delay None None 7UPE-DC * Off 9. Delay None None 7UPDE-DC * Delay 7UPB-DC * Off 858. Delay 7UPDB-DC * Delay 7UPF-DC * Off 99. Delay 7UPDF-DC * Relays - PMT Coil Burden: Inrush 5 Watts Sealed 5 Watts Contact Ratings - Amps Continuous D-C Applications Amperes Interrupting Rating Resistive Load Non-Inductive Inductive Load Volts N.O. N.C. N.O. or N.C. 6 or less Functioning of Economizing Interlock Pole D-C Relays X - Economizing electrical interlock (used in coil circuit) is one contact of standard universal pole. Typical connection of three terminal coil is shown. "ON-DELAY" (Time Delay after energization) "OFF-DELAY" (Time Delay after denergization) A-C Applications Volts Make Break Use complete catalog number. Replace the (*) with the suffix from Coil Table. Overlapping contacts are available in the same contact block at $8 per pair For timer with dial, specify "with dial" Add (each) $6. Price addition of $ per relay. For & 6 volt coils, use coil suffix or 6. $5 set up charge for 5 or less units Coil Table DC Voltage DC Voltage Suffix 8 8 DC Voltage Suffix

16 PM - Relays Engineering Data FRONT Hm H DC Contact Rating - P6 Amperes Volt Amperes Continuous Volts Make Break Make Break Amperes Wm W D Volts or Less All relays require a minimum of 7 /8 in. clearance below magnet for coil change. A horizontal space of /8 in. between relays is recommended. Mounting Holes For # Screws Relay Open Relay Type Cat. Number H W D Hm Wm PM-DC U,U,U 6 /8 / / U6,U8 6 /8 / / / PML-DC 5UHD 5 5 /6 5 /8 / 5UHD, 5UHD 5 5 /6 / 5 /8 / PMT-DC 7UP 6 /8 /8 / / 7UP-DC,-Pole 5 / /8 / 7UP-DC Pole 5 / / /8 / 7UP-DC Pole 5 / / /8 / 6

17 Coil Data Relays - PM Standard catalog listed AC relays ordered will have the proper coils as determined by the voltage and frequency suffix to the catalog number. Changing the circuit arrangement on a relay also changes the mechanical load on the magnet and may require a change of operating coil to assure proper operation. the information on this page will enable you to select the correct operating coil for any circuit arrangement required. Voltageampere requirements are provided to help in designing your panels. To select the proper operating coil for all For Example: Table indicates that the proper coil number for volts, 6 hertz application is TB-6, since the load factor of 68 falls within the Mechanical Load Range of 5 to 9. basic and latch relays except the Slim Jim, first determine the mechanical load on the magnet simply by totalling the load represented by the individual components operated by the magnet, using the mechanical load factors shown below. Select the proper coil from Table. When selecting the proper coil for Slim Jim Relays and Time Delay Relays, it is not necessary to determine the mechanical load Coil Application Tables - Type PM Relay Family Table factor. As shown in Table, one coil for each voltage and frequency will operate all pole combinations. Mechanical Load Factors: Convertible Pole - Normally Open... Convertible Pole - Normally Closed... Double Contact Pole - Universal or Duplex... 6 Latch Mechanism... Example: A relay with N.O. and 9 N.C. convertible poles and a latch mechanism will have a mechanical load factor as follows: N.O. Convertible Pole... 9 N.C. Convertible Poles... 8 Accumulation Factor... Latch Mechanism... Total Mechanical Load Factor Basic And Latch Relays Time Delay Relays Slim Jim Trip Coil Relays on Latch Mechanical Load Range All Pole Relays, All Class A (Does Not Apply To Slim Jim Relays) Combi- Pole Com- All Pole AC Volts Hertz nations binations Combinations Coil Catalog Numbers - Bulletin 7 & 75 PM & PML 6 TB-6 TB-7 TB TB9- TB7- TB TB- TB- TB-6 TB- TB9- TB7- TB5-5 TB- TB TB7- TB TB- TB-6 TB-6 TB- TB9- TB7- TB5-5 TB-8 TB TB7-5 TB5-5 6 TB-65 TB-6 TB-6 TB- TB9- TB7- TB5-8 5 TB-7 TB-8 TB-6 TB-9 TB9- TB7- TB5-9 5 TB- TB TB TB-7 TB-9 TB-6 TB-9 TB9- TB7- TB5-5 TB- TB TB TB-6 TB- TB-66 TB-6 TB9-6 TB7-6 TB TB- TB Volt -Amperes INRUSH SEALED INRUSH Refer to 8 SEALED Sales Office INRUSH Refer to 7 SEALED Sales Office 5 For relays with 9 or more normally closed convertible poles, an accumulation factor of must be added to to the total mechanical load factor for the relay 7

18 7 Relays Control Relays Description Series 7 relays are designed for AC and DC circuits where high reliability, versatility of contact and operating coil combinations, compact size, and high speed operation are required. The 7 relays are available up to 8 convertible poles, current ratings to amps AC and amps DC. Components (Table ) Base...and Coil Voltage Cat. No. Price Pole Base- VAC Coil 7-9- $. 8 VAC Coil VAC Coil VAC Coil Pole Base- VAC Coil VAC Coil VAC Coil Pole Base- 5 VDC Coil VDC Coil Pole Base- 5 VDC Coil VDC Coil Heavy Duty Coil, Suitable For Up To Circuits Heavy Duty Coil, Suitable For Up To 8 Circuits Note: Other AC and DC coil voltages are available. Please contact factory. Unit Poles - AC Load (Table ) 6VAC Max Description Cat. No. Price A, N.O $. A, N.C A, N.O A, N.C A N.O A N.C Tungsten or Resistive Loads, 77 VAC Max. Unit Poles - DC Load (Table ) 5VDC Max Description Cat. No. Price A, N.O. -Blowout 7-99 $66. A, N.O. -Blowout A, N.C. -Blowout A, N.C. -Blowout Rules to Select and Install Contacts A. When installing AC or DC contacts you should balance the mechanical load on the coil magnet preferably by placing the contacts together in the center and working your way out. - For a -pole contact install the contacts in sequence per the diagram listed below. - For an 8-pole contact install the contacts per this diagram Pole Base 8-Pole Base All DC contacts require a "Blowout Mechanism" to extinguish the "arc" during contact opening. See Rule "B" below. B. When installing DC contacts, using the contact sequence above, the last contact on the left must have two blowouts. All others will have only one. Example: If you have four contacts on the -pole base (table ), number must have two blowouts. If you have only two contacts, then number must have two blowouts. If you have six contacts on the 8-pole base (table ), number 5 must have two blowouts. Contacts seven and eight on the 8-pole base must have two blowouts. 5 5 Select and Price Base and Power Plant and Unit Poles Separately. Example: VAC Pole relay with N.O., N.C., Amp Poles. Dimensions: See Section L Page $ $. 8

Crane Control Contactors and Relays

Crane Control Contactors and Relays October 8 DC Relays Type KC Heavy-Duty Mill 75 Contact Conversion The fully visible contacts have NEMA ICS--5 heavy-duty interrupting ratings and are easily converted in the field using just a screwdriver

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

3.7. Control Relays and Timers.

3.7. Control Relays and Timers. Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................

More information

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description

3.7. Control Relays and Timers. Contents. BF/BFD Series Fixed Contact Industrial Control. Machine Tool Relays. Product Description Control Relays and Timers.7 BF/BFD Series Fixed Contact Industrial Control Contents D15 Series Freedom 600V Multipole.......... BF/BFD Series Fixed Contact Industrial Control Product Selection.......................

More information

Bulletin 700-P, 700DC-P Industrial Relays

Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700 P Direct Drive Convertible Contact Cartridge Relays NEMA and IEC ratings 600V maximum AC/DC Accessories for field installation: contact cartridges,

More information

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay

Contacts Contact Arrangement. 8-Pole Relay. 12-Pole Relay Bulletin -P Heavy-Duty Industrial s Product Selection DC-Operated s Rail Mount DIN Rail Mount Cat. No. Cat. No. -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD -Pole DC-P DC-PD DC-P DC-PD DC Coil

More information

Series CA7 Contactors

Series CA7 Contactors Series Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor line.

More information

CS7 Industrial Control Relays

CS7 Industrial Control Relays CS7 Industrial Control Relays Reliable, general purpose relays for heavy duty applications The base four pole CS7 relay can be expanded up to twelve poles with the addition of front and side mount auxiliaries

More information

Allen-Bradley Drives

Allen-Bradley Drives Overview/Product Selection Bulletin IEC Industrial Safety Relay Positively Guided/Mechanically Linked as Per IEC 947-5-1 Annex L Third Party Certification By SUVA Red Cover and Mechanically Linked Contact

More information

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information...

Ice Cube Relays. R2/R4 Plug-in Power Relays... G58 Technical Information... G63. R15 Plug-in Power Relays... G68 Technical Information... Ice Cube Relays R2/R4 Plug-in Power Relays... 58 Technical Information... 63 R15 Plug-in Power Relays... 68 Technical Information... 72 RUC Plug-in Power Relays... 76 Technical Information... 79 RY2 Plug-in

More information

ASCO 920 Remote Control (RC) Switches

ASCO 920 Remote Control (RC) Switches Maximum reliability and excellent value ASCO 920 Remote Control (RC) Switches ASCO 920 Remote Control Switch in Type Enclosure The ASCO 920 is designed as a feeder disconnect switch for load capacities

More information

920 Remote Control (RC) Switches

920 Remote Control (RC) Switches 920 Remote Control (RC) Switches ASCO is the global leader in power switching and controls ASCO 920 PRODUCT SPECIFICATIONS SWITCH ONLY (PANELBOARD MOUNTING) 1,2,3 () DIMENSIONS, IN.(MM) WIDTH HEIGHT DEPTH

More information

Bulletin 700-P, 700DC-P Industrial Relays

Bulletin 700-P, 700DC-P Industrial Relays Bulletin 700-P, 700DC-P Industrial Relays Adder Decks Description No. of N.O. Contacts Continuous Carrying Current [A] Arrangement Second Deck (0-pole) 0 700-PB00 Second Deck 700-PB40 Second Deck (4-pole)

More information

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158

Magnetic Circuit Protectors 153. Multi-Pole Circuit Protectors 154. APL/UPL, 205/295 Barriers 155. Configurations 156. Operating Characteristics 158 Magnetic Circuit Protectors 53 Multi-Pole Circuit Protectors 54 APL/UPL, 205/295 Barriers 55 Configurations 56 Operating Characteristics 58 Delay Curves 59 Specifications 64 APL/UPL Decision Tables 70

More information

Crane Control Class 9004

Crane Control Class 9004 Catalog 17 CONTENTS Description.....................................................Page Pricing and Ordering Information...................................... 140 Dimensions and Weights............................................

More information

E-Series General Specifications

E-Series General Specifications -Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire

More information

Series CA7 Contactors

Series CA7 Contactors C7 Series C7 Rugged, space saving and modular Sprecher + Schuh s newest contactor for applications up to 6HP Over years of design experience has produced Sprecher + Schuh s seventh generation contactor

More information

IELR Rail-Mount Series Magnetic Circuit Protectors

IELR Rail-Mount Series Magnetic Circuit Protectors IELR Rail-Mount IELR Rail-Mount Series Magnetic Circuit Protectors Introduction 92 Single Pole 93 Specifications 94 Operating Characteristics 95 Delay Curves 96 Approvals & Decision Tables 200 IELR Series

More information

Catalog Number Identification with Elements Explained V V V V X 347 V Hz

Catalog Number Identification with Elements Explained V V V V X 347 V Hz Owner s Manual 917 & 918 Remote Control Switches TABLE OF CONTENTS page Ratings & Installation... 1 2 Optional Accessories... 3 4 Troubleshooting & Parts Kits... 5 Wiring & Outline Diagrams... back of

More information

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error:

SSV-T and SSC-T High Drop-out Relay. Range amps amps amps amps. Operating Frequency: Temperature Error: 41-766.7 SSV-T and SSC-T High Drop-out Relay device. A magnetic armature, to which leaf-spring mounted contacts are attached, is attracted to the magnetic core upon energization of the switch. When the

More information

APL/UPL, 205/295 Series Magnetic Circuit Protectors

APL/UPL, 205/295 Series Magnetic Circuit Protectors APL/UPL, 205/295 APL/UPL, 205/295 Series Magnetic Circuit Protectors Introduction 68 Single & Multi-Pole 69 Barriers 7 Configurations 72 Operating Characteristics 74 Delay Curves 75 Specifications 80 Decision

More information

C 2 5 D N A A A

C 2 5 D N A A A Product Family Overview May 007 pplication Description These Cutler-Hammer ampere and horsepower rated devices from Eaton s electrical business are designed for service in applications such as Refrigeration,

More information

AZ420 MINIATURE GENERAL PURPOSE RELAY

AZ420 MINIATURE GENERAL PURPOSE RELAY MINIATURE GENERAL PURPOSE RELAY FEATURES Rugged construction for high reliability Life expectancy greater than 100 million operations DC coils to 11 V Power consumption as low as 2 mw per pole available

More information

407B 1/16 DIN Multi-Mode Timer

407B 1/16 DIN Multi-Mode Timer < Marsh Bellofram Group of Companies < Automatic Timing & Controls < Timer < 407B Series Downloadable Files: 407B Series 407B 1/16 DIN Multi-Mode Timer Selectable On-Delay/Off-Delay/Interval Timing Modes

More information

H3CA-8H-AC/100/110/120

H3CA-8H-AC/100/110/120 Solid-State Timer 1/16 DIN, Digital-Set Timer with 0.1 Second to 9,990 Hours Range 8 field-selectable operation modes Universal AC/DC supply voltage timers available Operations include ON-delay, Repeat

More information

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards

209/219/229 Multi-Pole Circuit Protectors 202 branch circuit applications such as EDP, air conditioners, panel boards The 29, E-Frame circuit breaker combines power switching with accurate, reliable circuit protection 29/29/229 Magnetic Circuit Protectors 99 in a compact single or multipole 249 Power Selector Breaker

More information

405A Timer with Instantaneous Relay

405A Timer with Instantaneous Relay < Marsh Bellofram Group of Companies < Automatic Timing & Controls < Timer < 405A Series Downloadable Files: 405A Series 405A Timer with Instantaneous Relay On-Delay version with instantaneous relay Selectable

More information

Installation, Operation

Installation, Operation Installation, Operation and RENEWAL PARTS IDENTIFICATION 4 (Supersedes PN400-2) MAY, 1986 Type RST and RSTO Unitary Electric Immersion Heaters RST PN400-3 161-049178-001 3 Schedule 40 Steel Pipe Immersed

More information

IELR Series

IELR Series IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 IELR Series Rail-Mount Hydraulic

More information

CS8 Industrial Control Relays

CS8 Industrial Control Relays CS8 Industrial Control Relays Despite increasing complexity, control systems and installations must become increasingly compact. And the CS8 Miniature Relay System packs maximum performance into minimum

More information

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and

More information

Magnetic Style Safety Interlock Switches

Magnetic Style Safety Interlock Switches Non-contact safety interlock switches are the best choice for washdown applications; the switch components are sealed and rated NEMA 4X, IEC IP67 Tolerant of dirt buildup, sensing distance, and alignment

More information

Control, Timing + Ice Cube Relays

Control, Timing + Ice Cube Relays ... 2 Technical Information... 14 CS8... 18 Technical Information... 21 RZ7-FS Electronic... 24 Technical Information... 34 RZ7-FE Electronic... 36 Technical Information... 42 Relpol Ice Cube Relays R2/R4

More information

Z-15GW2277 Z-15GW2277-B

Z-15GW2277 Z-15GW2277-B Basic Switch GENERAL PURPOSE General Purpose Basic Switch High precision basic switch in a variety of styles Wide margins of operating conditions increase the operating speed range Available in general

More information

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7

Table of Contents. Introduction... 2 Description...2 Specifications...3 Installation.. 5 Calibration.. 6 General Maintenance...7 User's Manual: Series 330I Model 330I DC-Powered Three-Way Isolator Table of Contents Page Introduction... 2 Description....2 Specifications....3 Installation.. 5 Calibration.. 6 General Maintenance...7

More information

V REG.-Nr. 3919, Z E214024

V REG.-Nr. 3919, Z E214024 General Purpose Relays SCHRACK Miniature Power PCB Relay MSR 1 pole 8 / 10 A, 1CO or 1NO contact High inrush currents with AgSnO contacts (TV4 = 65 A) 4 kv/8 mm coil-contact Reinforced insulation (protection

More information

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Miniature Hydraulic/Magnetic Circuit Breaker M-Series M-Series PDF elibrary The M-Series miniature hydraulic/magnetic circuit breakers

More information

D-Series. Circuit Breaker

D-Series. Circuit Breaker D-Series Circuit Breaker Designed for snap-on-back panel rail mounting on either a 35mm x 7.5mm, or a 35mm x 15mm Symmetrical Din Rail, allowing rapid and simple mounting and removal of the breaker. It

More information

APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG

APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG APG/UPG/IPG Series Existing Designs Only APG/UPG/IPG APG/UPG/IPG Series Hydraulic Magnetic Circuit Protectors INTRODUCTION IMPORTANT NOTICE: The APG/UPG is a legacy product and no new design-in orders

More information

Bulletin 871D Cylinder Position Inductive Style

Bulletin 871D Cylinder Position Inductive Style Bulletin 871D Cylinder Position Inductive Style Description Bulletin 871D cylinder position inductive proximity sensors are self-contained solid state devices. These devices are designed for sensing metal

More information

BE1-51 BE1-51/27C BE1-51/27R TIME OVERCURRENT RELAY

BE1-51 BE1-51/27C BE1-51/27R TIME OVERCURRENT RELAY BE1-51 BE1-51/27C BE1-51/27R TIME OVERCURRENT RELAY The BE1-51 Series of Time Overcurrent Relays is microprocessor-based to provide versatile overload and fault protection on 50Hz or 60Hz systems. ADVANTAGES

More information

must Operate Voltage (V)

must Operate Voltage (V) force-guided relays g7sa G7SA compact, Slim relays conforming to en Standards Relays with forcibly guided contacts (EN50205 Class A, certifi ed by VDE) Supports the CE marking of machinery (Machinery Directive)

More information

7511 / / / 711 / / 731 / Preset 27

7511 / / / 711 / / 731 / Preset 27 22 Timers Timers Electronic 23 7511 / 3410 23 6320 / 720-6300 24 ElectRo-MeCH 25 710 / 711 / 720 25 722 / 731 / 732 26 Preset 27 7932 27 Electronic 23 7511 Series 8 digit self powered LCD electronic timer

More information

Model 720 Electromechanical Hour Meter

Model 720 Electromechanical Hour Meter Model 720 Electromechanical Hour Meter A 5 figure (reset) or 6 figure (non-reset), AC hour meter encased in a rugged steel housing and designed to mil-spec environmental requirements. The non-reset models

More information

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever

16 g SS-01GL-FD SS-01GL-F SS-01GL-FT 50 g SS-01GLD SS-01GLD1 SS-01GLD2 SS-01GL SS-01GLT Simulated roller lever Snap Action Switch SS Subminiature Snap Action Switch Economical, subminiature snap action switch offers long service life (30 million operations minimum) All models are free from overtravel restrictions,

More information

Ihr autorisierter Distributor: Neumüller Elektronik GmbH

Ihr autorisierter Distributor: Neumüller Elektronik GmbH IELR Series Rail-Mount Magnetic Circuit Protectors Introduction Poles Specifications Operating Characteristics Delay Curves Approvals Decision Tables 6 62 63 64 65 69 70 Neumüller Elektronik GmbH Gewerbegebiet

More information

ALTERNATING RELAYS & CONTROLLERS ARM Series

ALTERNATING RELAYS & CONTROLLERS ARM Series ALTERNATING RELAYS & CONTROLLERS ARM Series Process Control Equipment for Hazardous Locations 7M26 UL913 INCLUDES INTRINSICALLY SAFE INPUTS Integrated Duplex Controller SOSO Operation (Sequence-on, Simultaneous-off)

More information

Actuator Terminal Model

Actuator Terminal Model Sealed Snap ction Switch D2VW Watertight Miniature Snap ction Switch High-quality watertight, high-precision miniature Snap ction switch. Switch Body meets IP67 requirements Use of epoxy resin assures

More information

Contents. Volume 8 Sensing Solutions CA E February

Contents. Volume 8 Sensing Solutions CA E February Limit Switches.2 Product Description The E47 Compact Prewired Limit Switch by Eaton s electrical sector is designed to be a versatile, slim device for hard to fit applications where sealing integrity is

More information

Time Delay Values (E-Series)

Time Delay Values (E-Series) Time Delay Values (ESeries) AC Instantaneous 00 0 INSTANTANEOUS CURVE NO. 20 00 0 DC D.C. INSTANTANEOUS CURVE NO. 0 0. 0..0.0.00 200 300 400 500 700 800 900 0 200.00 200 300 400 500 700 800 900 0 200 Short

More information

Conveyor Belt Alignment Switches from IDEM

Conveyor Belt Alignment Switches from IDEM Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters

ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Lecture 6 Contactors and Motor Starters ECET 211 Electric Machines & Controls Lecture 6 Contactors and Motor Starters (1 of 2) Text Book: Chapter 6, Electric Motors and Control Systems, by Frank D. Petruzella, published by McGraw Hill, 2015

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display

Digital Timer. Ordering Information. 1/16 DIN, Quartz Timer with Four-Digit LED Display Digital Timer 1/16 DIN, Quartz Timer with Four-Digit LED Display Five wide ranges to choose from Wide-range AC or DC supply voltages Elapsed time (UP) or time remaining (DOWN) display available Selectable

More information

File E41515 Vol. 5 Sec. 5 Page 1 Issued: and Report Revised:

File E41515 Vol. 5 Sec. 5 Page 1 Issued: and Report Revised: File E41515 Vol. 5 Sec. 5 Page 1 Issued: 11-29-73 and Report Revised: 8-10-01 DESCRIPTION PRODUCT COVERED: Type MY may be followed by Q, followed by 4, may be followed by H3YN or H3YW (Amendment), may

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Spec-00252 Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories Modular Disconnect Enclosure, Type 12 INDUSTRY STANDARDS UL 508A Listed; Type 12; File No. E61997

More information

Single Pole Circuit Breakers 83 Multi-Pole Circuit Breakers 84 APGHX/UPGHX Breakers 86 APGX/UPGX Breakers 87 APGN/UPGN Breakers 88 APG/UPG Handles

Single Pole Circuit Breakers 83 Multi-Pole Circuit Breakers 84 APGHX/UPGHX Breakers 86 APGX/UPGX Breakers 87 APGN/UPGN Breakers 88 APG/UPG Handles Single Pole Circuit Breakers 83 Multi-Pole Circuit Breakers 84 APGHX/UPGHX Breakers 86 APGX/UPGX Breakers 87 APGN/UPGN Breakers 88 APG/UPG Handles and Actuators 89 IPG Breakers 90 Configurations 9 Operating

More information

Sensing and Control the Interactive Catalog.

Sensing and Control the Interactive Catalog. Interactive Catalog Supplements Catalog PDFs If you need detailed product information, or help choosing the right product for your application, see our Interactive Catalog Use the Interactive Catalog to

More information

SECTION ELECTRICAL CONTROL DEVICES

SECTION ELECTRICAL CONTROL DEVICES ELECTRICAL CONTROL DEVICES PART 1 GENERAL 01 02 03 04 05 SCOPE The Contractor shall furnish and install, where indicated on the drawings, equipment with electrical control devices installed as specified

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories 763.422.2600 SPEC-00252 N763.422.2211 DISCONNECT FREE-STAND UNIVERSAL-CUTOUT DISCONNECTS TYPE 12 MODULAR FREE-STAND DISCONNECTS AND ACCESSORIES Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

FT & RT Test Switches

FT & RT Test Switches GE Grid Solutions FT & RT Test Switches Key Benefits The FT Switches and FT Test Plugs have all the features necessary for applications involving the measurement of individual currents and voltages to

More information

Latching, Sequence and Impulse Relays Application Data

Latching, Sequence and Impulse Relays Application Data Latching, Sequence and Impulse Relays Application Data Energy Conservation Relays In many applications it is important for the customer to conserve electrical energy. One approach to energy conservation

More information

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application

S&C IntelliRupter PulseCloser Fault Interrupter Overhead Source-Transfer Application Overhead Source-Transfer Application Detailed Functional Specification Guide 1.0 GENERAL 1.01 The automated distribution fault-interrupting system shall conform to the following specification. 1.02 The

More information

3RA13, 3RA14 Contactor Assemblies

3RA13, 3RA14 Contactor Assemblies RA1, RA Contactor Assemblies RA1 complete units,... kw Overview The RA1 reversing contactor assemblies can be ordered as follows: Sizes S00 to S Fully wired and tested, with mechanical and electrical interlock

More information

Solid State Relays and Timers Family

Solid State Relays and Timers Family Solid State Relays and Timers Family Vehicle Control Modules Waytek Stock No. Volt Rating Amp Rating Notes Dual Input Relay Activating either Input A or Input B sets output. 75532 12 15 Dual inputs Latching

More information

PERCENT OF RATED CURRENT

PERCENT OF RATED CURRENT A-D Series Time Delay Values PERCENT OF RATED CURRENT NOTES: UL489 C-Series Breakers available with Delay Curves 11, 12, 14, 16, 21, 22, 24, 26, 42, 44, 46. Delay Curves 11,12,14,16,21,22,24,26,42,44,46,52,54,56:

More information

Posi-Lok Plugs and Panels

Posi-Lok Plugs and Panels THE SAFEST ELECTRICAL SYSTEM FOR HIGH AMPERAGE CONNECTIONS, POSI-LOK IS PART OF THE CAM-LOK FAMILY OF CONNECTORS. THE GROUND ALWAYS MAKES FIRST AND BREAKS LAST ALL POSI-LOK SYSTEMS ARE UL LISTED AND CSA

More information

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch

SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch installation instructions SmartClose 3-phase, Synchronous Close Vacuum Capacitor Switch 2013 Hubbell Incorporated hpsliterature@hubbbell.com hubbbellpowersystems.com The equipment covered by these installation

More information

MICRO SWITCH Military-Grade Toggle Switches. TL Series. Datasheet

MICRO SWITCH Military-Grade Toggle Switches. TL Series. Datasheet MICRO SWITCH -Grade Toggle Switches TL Series Datasheet MICRO SWITCH TL Series Toggle Switches Honeywell MICRO SWITCH TL Series toggle switches are military qualified to MIL-DTL-3950, specifications for

More information

C-Series. Circuit Breaker

C-Series. Circuit Breaker C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

SECTION DISCONNECT SWITCHES

SECTION DISCONNECT SWITCHES SECTION 16440 DISCONNECT SWITCHES PART 1 - GENERAL 1.01 RELATED DOCUMENTS A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and other Division 01 Specification

More information

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- -

D2VW. Sealed Miniature Basic Switch. Ordering Information Model Number Legend D2VW- - Sealed Miniature Basic Switch Sealed Miniature Basic Switch Conforms to IP67 (Molded Lead Wire Type Only) Use of epoxy resin assures stable sealing, making this switch ideal for places subject to water

More information

C-Series. Circuit Breaker

C-Series. Circuit Breaker C-Series Circuit Breaker The C-Series hydraulic/magnetic circuit breakers are ideal for applications that require higher amperage and voltage handling capability in a smaller package. They are available

More information

Specifications. Description TABLE OF CONTENTS. Page. Description 2. Specifications 2 3. Additional Options 3. How to Order 4 5

Specifications. Description TABLE OF CONTENTS. Page. Description 2. Specifications 2 3. Additional Options 3. How to Order 4 5 TABLE OF CTENTS Page Description Specifications Additional Options How to Order Circuit Descriptions Dimensions 0 Icons into the body of the switch; mounting hardware or special tools are not necessary.

More information

Telephony Multi-Taps. 9000T-TP Series

Telephony Multi-Taps. 9000T-TP Series 9000T-TP Series The 9000T-TP series 1 GHz twisted-pair power multi-tap taps off part of its input RF and AC, but lets the rest pass through. It divides the tapped-off signal and power into multiple outputs,

More information

Limit Switches E47 Precision Switches

Limit Switches E47 Precision Switches June 09 E7 Precision Switches PG.0C.0.T.E 1 E7 Precision The Cost-Effective Solution for Highly Accurate Switching Applications Contents Overview...................... 1 Model Selection, Basic Switches................

More information

SERIES FEATURE MAX RATING MECHANICAL LIFE APPROVALS CIRCUITRY. B1 Ultra Small 2A 100,000 N/A SPST, SPDT

SERIES FEATURE MAX RATING MECHANICAL LIFE APPROVALS CIRCUITRY. B1 Ultra Small 2A 100,000 N/A SPST, SPDT SWITCH SELECTION GUIDE Basic Switches SERIES FEATURE MAX RATING MECHANICAL LIFE APPROVALS CIRCUITRY (Resistive) B1 Ultra Small 2A 100,000 N/A SPST, SPDT B1-5 Levers 2A 1,000,000 N/A SPST, SPDT B2 Subminiature

More information

Magnetically Actuated Safety Interlock Switches

Magnetically Actuated Safety Interlock Switches Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,

More information

D2SW-3L1HS D2SW-01L1HS

D2SW-3L1HS D2SW-01L1HS Sealed Snap Action Switch D2SW Watertight Miniature Snap Action Switch High-quality watertight miniature Snap Action switch. Switch Body meets IP67 (IEC 529) requirements Monoblock construction assures

More information

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories

Free-Stand Universal-Cutout Disconnects Type 12 Modular Free-Stand Disconnects and Accessories 763.422.2600 Spec-00252 L763.422.2211 Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and accessories Free-Stand Universal-Cutout s Type 12 Modular Free-Stand s and Accessories Modular Enclosure,

More information

SAFETY LOCKING DEVICES

SAFETY LOCKING DEVICES L200 Heavy-Duty L200 Safety Locking Device on a very large gate in a logistics operation with forklift traffic The L200 Safety Locking Device designed for highly demanding applications is predestined for

More information

HIGH DENSITY TERMINAL BLOCKS

HIGH DENSITY TERMINAL BLOCKS CONTROL LOGIC HIGH DENSITY TERMINAL BLOCKS c3controls new line of High Density terminal blocks are both innovative and user-friendly. Available in multiple terminal points from 4, 6, and 12 in a single

More information

page 28 page 30 page 30 page 31

page 28 page 30 page 30 page 31 25 Gardner Bender switches are available in many different styles and sizes. They are used in countless applications, from basic on-off to multifunction applications. page 28 page 30 page 30 page 31 _Section_0512.indd

More information

Distinctive Characteristics

Distinctive Characteristics Distinctive Characteristics Full face, bright LED illumination in choice of red, green, and amber for visible status indication. 9-amp or 6-amp electrical capacity in compact body. Interior shield prevents

More information

For full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.

For full product information, visit  Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. R Safety Monitoring Relays For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Dual-Channel Safety Monitoring Relay Power

More information

Mini Contactors & Overloads

Mini Contactors & Overloads 108 Mini s & Overloads GMC-12M Surface or DIN rail mountable UL508 compliant 1/ to 7-1/ 50/60Hz AC and DC versions available Direct-mounting overloads RoHS compliant Auxiliary contacts standard (1 N.0.)

More information

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004

HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004 HUNTERSVILLE, NORTH CAROLINA USA EFFECTIVE SEPTEMBER 1, 2004 EPA Green Lights A L L Y USE OF THIS LOGO DOES NOT IMPLY EPA ENDORSEMENT JANUARY 2008 www.nsiindustries.com E-mail: nsi@nsiindustries.com Fax:

More information

Exercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION

Exercise 1-4. Contactors and Control Relays EXERCISE OBJECTIVE DISCUSSION OUTLINE DISCUSSION Exercise 1-4 Contactors and Control Relays EXERCISE OBJECTIVE Identify the characteristics of control relays and contactors. DISCUSSION OUTLINE The Discussion of this exercise covers the following points:

More information

Micro Contactor MA Series

Micro Contactor MA Series Relay-sized contactor, making it the world s smallest >3mm contact clearance acc. to IEC 60335-1 for Safety Applications Reversing contactor with mechanical interlock 3 Pole and 1 Aux. Contact NO or NC

More information

RL Line/Load Reactors

RL Line/Load Reactors RL Line/Load Reactors Selection Table, Technical Details & Product Application Guide MTE HARMONIC COMPENSATED LINE/LOAD REACTORS help keep your equipment running longer by absorbing many of the power line

More information

ZLS Series Global Limit Switches

ZLS Series Global Limit Switches GENERAL INFORMATION ZLS series limit switches are specifically designed for worldwide applications and is supported by Honeywell global resources for sales and after sales service. ZLS series limit switches

More information

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers

MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL. Basic Outline of Operation for Distro Controllers MOTION LABORATORIES CHAIN HOIST MOTOR CONTROL SYSTEMS MANUAL Forward The main body of text in this manual concerns four through eight channel portable chain hoist motor control systems with 208-230 VAC

More information

Bulletin 700-HL 2-Pole Terminal Block Relay

Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole Terminal Block Relay Bulletin 700-HL 2-Pole "Terminal Block Relay" Relay and socket assembled interface modules for high density interposing or isolation applications Screw terminal

More information

Ultra Slim Relays 24

Ultra Slim Relays 24 Ultra Slim Relays 24 Technical Data... 1 Specifications.2 Model Number Structure - Relays...3 Model Number Selection...4 Accessories...5 Safety Precautions...6 Ultra Slim Relays WERNER`s embody the latest

More information

FieldLink process networking

FieldLink process networking FieldLink process networking Enclosures Junction module (JM) StoneL s Junction Module (JM) enclosure is an environmetally hardened platform which is suitable for use in the most extreme corrosive and hazardous

More information

Allen-Bradley Bulletin 100 Contactors

Allen-Bradley Bulletin 100 Contactors Allen-Bradley Bulletin 100 Contactors An integrated portfolio of IEC Contactors that save panel-space and energy Features and Benefits: Direct-on-line and reversing contactors Built-in surge suppression

More information

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount.

This Datasheet for the IC697CHS790. Rack, 9 Slots, Rear Mount. This Datasheet for the IC697CHS790 Rack, 9 Slots, Rear Mount. http://www.cimtecautomation.com/parts/p-14771-ic697chs790.aspx Provides the wiring diagrams and installation guidelines for this GE Series

More information