SERIES 200. k POWER DISTRIBUTION PANEL SERIES 200

Size: px
Start display at page:

Download "SERIES 200. k POWER DISTRIBUTION PANEL SERIES 200"

Transcription

1 The power distribution panels series 200 combine user comfort through a simple design and technical dependability. Each circuit is switched and protected by a thermic circuit breaker with its own rocker switch (ETA 3130). It contains an integrated light diode that shows circuit status. In case of short circuit, the breaker switches automatically off and the light is off. Once the problem is corrected, the breaker can be manually pushed to ON position. Each circuit breaker has an internal failsafe mechanism that will not react (turn on) during a problem in circuitry until the problem is solved. SERIES 200 The measurements of the power distribution panels are matching to each other to allow the choice of vertical or horizontal combination. Cut-out dimensions will be smaller of 13 mm each edge. Rocker switch circuit breakers with 10A are normally built in, but can be changed on request to 6A, 16A, or 20A. Circuit breakers are connected on the reversed side with spade terminals 6,3mm. Self adhesive labels are included. LKZ -GB Order-No.: Self illuminating circuit labels provide a good reading even at night! Please order separately (optional accessory). All informations about the labels listed here on Circuit labels for panel series 200. Set of self adhesive labels, which can be placed at each circuit breaker on the signed field. Included in delivery. 04 SKZ -D Order-No.: SKZ -Mobil (Automotive) Order-No.: SKZ -GB Order-No.: SKZ -NL Order-No.: SKZ -ES Order-No.: SKZ -DK Order-No.: SKZ -FR Order-No.: SKZ -PL Order-No.: Professional tin plated copper bus bars are connecting the power supply side of each indivdual breaker to each other. This provides a reliable contact during operation especially in marine environment.

2 During short circuit or overload, the light goes out and the switch clicks to the off position. Once the problem is corrected, the breaker can be renewly switched to the on position for continued use. The circuit breakers have an intern trip switch that cannot be inflenced during a problem by pressing on the rocker switch. Digital monitors for battery supervision, battery charger control und tank monitoring Control switches for a comfortable system control. Labelling through a self adhesive label. Switching from a remote control switch (1)-0-(2) Bilge pump (auto-manual, 1-2) Voltmeter switch-over battery Tank alarm switch on-off Monitoring switch (Tank 1-0-2) Panel lighting on-off Inverter on-off Low discharge protection Power distribution panel with a navigation light display reveals the position of a position light failure through a control light and an alarm. The acoustic alarm is acknowledgable by push button. 05

3 STV 210 Order-No.: power circuits with thermal circuit breakers 10 A. STV 207 Order-No.: power circuits with thermal circuit breakers 10 A, 2 Power-sockets for pin 21mm. Suitable terminal blocks type Type RKL 10. W 105 x H 210 x D 70 mm Suitable terminal blocks type Type RKL 10. W 105 x H 210 x D 70 mm STV 204 SY Order-No.: power circuits with thermal circuit breakers 10 A, display sailing yacht positionlights including electronic position light monitor POS 6. for 12V and 24V and for use with LED -lanterns or normal bulbs W 105 x H 210 x D 70 mm STV V Order-No.: STV V Order-No.: power circuits with thermal circuit breakers 10A, illuminated voltmeter with switch over. Suitable terminal blocks type RKL 16/4 W 105 x H 210 x D 70 mm 06 STV 208 Order-No.: power circuits with thermal circuit breakers 10 A STV 204 Order-No.: power circuits with thermal circuit breakers 10 A Suitable terminal blocks type RKL 10 W 210 x H 105 x D 70 mm Suitable terminal blocks type RKL 10 W 105 x H 105 x D 70 mm

4 STV 220 Order-No.: power circuits with thermal circuit breakers 10 A STV V Order-No.: STV V Order-No.: power circuits with thermal circuit breakers 10A, volt- and ammeter (0-40 A), 3 control switches (0-1, 1-0-2, 1-2) for individual use. Suitable terminal blocks type RKL 20 W 210 x H 210 x D 70 mm Suitable terminal blocks type RKL 16/4 W 210 x H 210 x D 70 mm STV 202 MS Order-No.: power circuits with thermal circuit breakers 10 A and display power boat with electronic monitor POS 6. STV Order-No.: circuits with rocker switch (31,5x14 mm) and lamp diodes display. Rocker switches can exchanged to other models, please find on page 21. W 210 x H 105 x D 70 mm W 105 x H 105 x D 50 mm STV V Order-No.: STV V Order-No.: power circuits with thermal circuit breakers 10A, Moving coil gauge, class 1,5: voltmeter, ammeter 0-40 A and tank level instrument. 6 control switches (0-1, 1-0-2, 1-2) for individual use. and. display Sailing Boat with electronic position light monitor POS 6. Suitable terminal blocks type RKL 20 07

5 The models STV 222, STV 224 and STV 264 make the complete protection and monitoring for a medium sized sailing yacht possible with one panel. Apart from the thermal protection of the electric circuits a position lamp monitoring with notification of failure is available. Freely provable switches for controling remoteable main switches, bilge pump automatics, inverter, loudspeaker change over switch and further arbitrary applications. In place of the digital battery monitor BCM e.g. also a charger monitor LCM or a tank monitor TCM can be inserted. Active shunt for battery monitor or the PSM and further PBUS components for the PSM have to be ordered separately! STV 215 Order-No.: power circuits with thermal circuit breakers 10 A, Battery monitor BCM. Shunt SHA has to be ordered separately! (see page 30). STV 224 Order-No.: power circuits with thermal circuit breakers 10 A, Battery monitor BCM (alternatively monitors TCM or LCM can be ordered), display sailing yacht incl. position light monitor POS 6 with alarm, 2 sockets DC und 2 control switches for individual use. Shunt SHA has to be ordered separately! (see page 30). W 210 x H 210 x D 70 mm Suitable terminal blocks type RKL 16/4 Suitable terminal blocks type RKL 30 STV 228 Order-No.: STV 222 Order-No.: power circuits with thermal circuit breakers 10A, battery monitor BCM 1, tank monitor TCM 4, socket DC and 2 control switches for individual use. Shunt SHA has to be ordered separately! W 210 x H 210 x D 70 mm Suitable terminal blocks type RKL power circuits with thermal circuit breakers 10 A, battery monitor BCM (alternatively monitors BLM or LCM can be ordered), tank monitor TCM 4, display sailing yacht incl. position light monitor POS 6 with alarm, 2 sockets DC and 2 control switches (0-1, 1-0-2) for individual use. Shunt SHA has to be ordered separately! (see page 30). Suitable terminal blocks type RKL 20

6 Power distribution panels with system monitor PSM integrated for supervision of batteries, tanks, energy, AC mains and switching as well as connection of further PBUS - components. USB - socket only for use with 12V power supply. STV 250 Order-No.: STV 264 Order-No.: power circuits with thermal circuit breakers 10A, system monitor PSM. DC- and USB-socket, 2 switches (0-1, 1-0-2). Shunt and further PBUS components have to be ordered separately! 24 power circuits with thermal circuit breakers 10 A, philippi system monitor PSM, display sailing yacht incl. position light monitor POS 6 with alarm, DC- and USB- socket and 2 control switches (0-1, 1-0-2) for individual use. Shunt and further PBUS components have to be ordered separately! (see page 26). W 210 x H 210 x D 70 mm Suitable terminal blocks type RKL 16/4 Suitable terminal blocks type RKL 30 Installation example Left: Combination of different panels and blank panels series of 200 Right : Produced panel according to the customer demand. 09 Battery, tank, temperature and AC monitors (see page 28) System monitor PSM for supervision of batteries, tanks, energy, AC mains, switching and connection of further PBUS-components (see page 24)

7 k POWER DISTRIBUTION PANEL DOUBLE POLE In order to protect the power circuits on aluminium and steel vessels double pole circuit breakers are fitted to ensure a complete galvanic isolation from the vessels hull. The thermic- circuit breakers E-T-A 3130 are exchangeable and may be readily combined in power circuits. The circuit breakers are available in the power ratings 6 A/10 A/16 A. circuit breakers with a rating of 10 A are fitted as standard. The power circuits are marked with self-adhesive labels which are included. Suitable terminal blocks please find at page 72. STV ISO Référence.: Panel for hull isolation control. Double pole button with 2 LEDs for testing. Hull will be isolated when both LEDs are on while pressing the button. For both 12V and 24V. W 105 x H 52,5 x D 70 mm STV 206-2p Order-No.: power circuits with thermal circuit breakers 10 A, double-pole. STV 214-2p Order-No.: power circuits with thermal circuit breakers 10A, battery monitor BCM (alternatively monitors TCM or LCM can be ordered), display sailing yacht incl. electronic position light monitor POS 6 with alarm, 2 sockets DC and hull isolation test. Shunt SHA has to be ordered separately! (see page 30). W 105 x H 210 x D 70 mm Suitable terminal blocks type RKL 14 Suitable terminal blocks type RKL STV 212-2p Order-No.: power circuits with thermal circuit breakers 10 A, double pole. W 210 x H 210 x D 70 mm Suitable terminal blocks type RKL 14 STV 254-2p Order-No.: power circuits with thermal circuit breakers 10A, system monitor PSM, display sailing yacht incl. electronic position light monitor POS 6 with alarm, DC- and USB - socket and hull isolation test- Shunt and further PBUS components has to be ordered separately! (see page 36) Suitable terminal blocks type RKL 14

8 Along with power distribution panels of the series 200, there are shore power connection units available. The electrical connection will be done on the reverse side on terminal clamps. The terminal clamps are constructed to be hands on safe. For safety reasons, the panel has to be istalled so that the reverse side is covered and only accessible with the help of tools. For an extension such as a switching units, see page 46. LAM Order-No.: Shore power indication light for the AC- system. The power indication light shows the correct electrical connection of the shore power. Green means: connection is correct ; red means that the phase (L) and the neutral (N) is changed. Is one of the three cables faulty (L/N/PE) the display is blinking. Power consumption 2,7 ma, Leakage current 1,4 ma, 2 ma while flashing. W 105 x H 52,5 x D 50 mm LAE 235 Order-No.: Shore power unit with RCBO leakage protector (16A/ 30mA), power indication light and a Schuko socket. Connection with terminal clamps on rear side.. LAE 232 Order-No.: Shore power unit with RCBO leakage protector (16A/ 30mA), power indication light and 2 double pole thermial circuit breakers 10 A for 230V / 50 Hz. Connection with terminal clamps on rear side. LAE 236 Order-No.: double pole power circuits with thermal circuit breakers 10A for AC 230V / 50 Hz.. A panel with a RCBO leakage protector has to be installed before the input of this panel! W 105 x H 210 x D 100 mm W 105 x H 210 x D 100 mm W 105 x H 210 x D 70 mm LAE 234 LG Order-No.: LAE 234 LGW Order-No.: LAE 234 LGK Order-No.: Shore power unit with RCBO leakage protector (16A/ 30mA), 1 power indication and 2 monitor lights and 4 double pole thermal circuit breakers 10 A for AC 230 V /50 Hz. Shore- Generator-(LG) oder Shore-Generator-Inverter (LGW) -switch over and voltmeter 230 V. 230 V/50 Hz. Connection with terminal clamps on rear side. W 210 x H 210 x D 110 mm Shore power unit for inverter/charger-combination with shore-generator-switch over with limit of use of consumers while the inverter is running. RCBO leakage protector (32 A/30 ma), 1 power indication and 2 monitor lights and 4 double pole thermal circuit breakers 10 A for AC 230 V/50 Hz. Shore-generator-switch over (25A) and voltmeter 230 V. Connection with terminal clamps on rear side. Generator set max. 6 kw. Stronger models on request. W 210 x H 210 x D 110 mm 11

9 k ACCESSORIES FOR POWER DISTRIBUTION PANEL SERIES 200 BPA 200 Order-No.: Panel to choose bilge pumps operation between manually on-off or automatic. Outlet is protected against overload and short circuit by a circuit breaker. A LED indicates the operation of the bilge pump. well matched to the panels series 200. Rated voltage Rated current DC 12/24 V 16 A W 105 x H 52,5 x D 60 mm EBSN 10 (10 A) Order-No.: EBSN 20 (20 A) Order-No.: The electronic bilge pump switch turns on the bilge pump automatically by intrusion of water and shuts off when the water is gone. Two integrated stainless steel sensors will become active as soon as they come in contact with water. A switch on delay (5 s) prevents the function in case of a short water contact by a rolling boat. A delay in switch off (20 s) enables a completely pumping out of bilge. The fastening slots on each side simplifies the mounting adjustments. Watertight housing. Rated Voltage / Amperage 12 V, 7 ma / 24 V, 7,5 ma Max. current 10 A bzw. 20 A / Weight L 85 x W 75 x H 35 mm / 400 g Blank panel Blank 200 Order-No.: W 105 x H 52,5 x D 2,5 mm Blank 201 Order-No.: W 105 x H 105 x D 2,5 mm Blank 202 Order-No.: W 210 x H 105 x D 2,5 mm Blank 200 R Order-No..: Blank panel for car radio with DIN cut-out (18,3 x 55 mm) STV 223 Order-No..: Blank panel for 3 analog meters for individual choice (voltage, current, tank measurement). Meters has to be ordered separately. Panel can be installed also vertical!! Blank 204 Order-No.: W 210 x H 210 x D 2,5 mm W 210 x H 105 x D 2,5 mm W 210 x H 105 x D 70 mm k METERS Instrument W 48 x H 48 x D 46 mm Cut-out W 45,5 x H 45, 5 mm Analog precision meter with LED illumination More models available on request. Voltmeter DC Ammeter DC Voltmeter AC (no illumination) SQB 8-16V Order-No.: SQB 0-40A Order-No.: SQB 250V (AC) Order-No.: SQB 16-32V Order-No.: Tank gauge (DC 10-30V) for TGT/TGW Ammeter DC for external shunt Ammeter AC (no illumination) 12 SQB Water (10-180V) No.: SQB Fuel (10-180V) No.: SQB 0-40A/60mV Order-No.: SQB 0-60A/60mV Order-No.: Shunt 40 A/60 mv Order-No.: Shunt 60 A/60 mv Order-No.: SQB 0-15/30A Order-No.: SQB 0-25/50A Order-No.: Frequencymeter AC (no illumination) ZQB 50 Hz Order-No.:

10 k POSITION LIGHT MONITOR Up to six navigation lights can be connected to the new designed position light monitor POS 6. Either LED positions lanterns or classic bulb lanterns can be monitored of their regular function. The failure of a lantern will be announced by an optical and an acoustic alarm, which can be acknowledged. Further the relating diode will be blinking on the display. The position light monitor POS 6 can be added to all existing installations. POS 6 Order-No.: For installation of an individual position light control with separate electronic incl. an alarm Rated voltage DC V Channels 6 with alarm Max. power 3 A each outlet Breaking capacity 0,2-36 W/12 V 0,5-72 W/24 V Switch level 10 ma Voltage drop max. 0,1 V (3 A) Own consumption ma W x H x D 88 x 126 x 27 mm POS 6 E Order-No.: Replace electronic for modification of older STV panels with position light control with alarm for the use with LED - lanterns. Incl. control-leds. Easy to replace! k THERMAL CIRCUIT BREAKER E-T-A 3130 Single pole DC: single pole rocker switch/thermal circuit breaker of compact design for snap-in panel mounting. Black with silver frame. Cut out dimensions 14,8 x 34,2 mm, Width 18 mm. Rated voltage DC 30 V, Power consumption of the LED: 4 ma at 12 V Circuit breakers available ex stock 3130-F11B-H7T1-W29AG3-6A Order-No.: F11B-H7T1-W29AG3-10A Order-No.: F11B-H7T1-W29AG3-16A Order-No.: F11B-H7T1-W29AG3-20A Order-No.: F11B-H7T1-W29AG3-30A Order-No.: (30 A: width like double pole version) 3130-F11B-H7T1-U29AG3-10A (push butt..) Order-No.: Double pole DC: double pole rocker switch/thermal circuit breaker. Cut out dimensions 26,3 x 34,2 mm, Width 29,3mm, Rated voltage DC 30 V, 3130-F12B-H7T1-W29AG3-6A Order-No.: F12B-H7T1-W29AG3-10A Order-No.: F12B-H7T1-W29AG3-16A Order-No.: F12B-H7T1-U29AG3-10A (Taster) Order-No.: Double pole AC 230 V: double pole rocker switch/thermal circuit breaker F12B-H7T1-W24AB7-6A Order-No.: F12B-H7T1-W24AB7-10A Order-No.: F12B-H7T1-W24AB7-16A Order-No.: F15B-P7T1-W24AB7-20A Order-No.:

AUTOMATIC SHORE GENERATOR (INVERTER)- SWITCH OVER UNIT FOR 2 SOURCES LAU 216 (F)

AUTOMATIC SHORE GENERATOR (INVERTER)- SWITCH OVER UNIT FOR 2 SOURCES LAU 216 (F) OPERATION MANUAL AUTOMATIC SHORE GENERATOR (INVERTER)- SWITCH OVER UNIT FOR 2 SOURCES LAU 216 (F) INTRODUCTION If an AC generator or inverter is installed on board a yacht or vehicle, it is necessary to

More information

MEASURING AND TESTING INSTRUMENTS

MEASURING AND TESTING INSTRUMENTS MEASURING AND TESTING INSTRUMENTS Whether measuring temperature, current or voltage testing the right measuring tool can facilitate the everyday work. If one wants to perform several measuring tasks at

More information

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1

BEP 600-ACSM AC SYSTEMS MONITOR. Installation and Operating Instructions. Page 1 BEP 600-ACSM AC SYSTEMS MONITOR Installation and Operating Instructions Page 1 This page has been deliberately left blank Page 2 Table of Contents 1. BASICS 4 WARNING AND CAUTION 4 WARNING 4 CAUTION 4

More information

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling

Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling Transparent Covers for Rail-Mounted Terminal Blocks, Usable with Lead Seals Description and Handling 572 Assembly Application Snapping a cover carrier onto the carrier rail. Application examples: cover

More information

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24 Bar graph displays For process control, automation, and laboratory applications Current, voltage, resistance, frequency and temperature Up to 0.5% resolution DINALOG A 96 x 24 Programmable quasi-analogue

More information

Abstract. GLV User Manual 1

Abstract. GLV User Manual 1 GLV User Manual 1 Abstract This user manual is a high level document that explains all operational procedures and techniques needed to operate the GLV system in a safe and effective manner. Anyone operating

More information

BMS: Installation Manual v2.x - Documentation

BMS: Installation Manual v2.x - Documentation Page 1 of 7 BMS: Installation Manual v2.x From Documentation This section describes how external peripheral devices are connected and additional functions of the BMS are used. I you have not done so already,

More information

CAMERA-MONITOR SYSTEMS

CAMERA-MONITOR SYSTEMS CAMERA-MONITOR SYSTEMS FOR RECREATIONAL AND COMMERCIAL APPLICATIONS INSPIRED BY COMFORT 150546_reversing Brox2015V2_AM.indd 1 16/06/2015 3:42 pm 2 PERFECT VIEW SOLUTIONS READY-TO-INSTALL SYSTEMS FOR EVERY

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to -point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks

Networks TN, TT, IT networks 3 and 4-phase networks Up to 4 single-phase networks Memory 256 MB 8 Tariffs Harmonics Pulse inputs and outputs Measurement accuracy 0.5 UMG 96RM Multifunction power analyser Communication (device-specific) Modbus (RTU) Profibus DP V0 Profinet TCP/IP M-Bus

More information

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding

GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding GFCI (RCD) RECEPTACLES AND PLUGS 2 Pole 3 Wire Grounding AU1-10R AU1-10P FR1-R EU1-P Cat. No. Drawing Configuration Australian GFCI (RCD) angle plug. trip. 10 ampere 230 volt, 50 Hz. 20 watt maximum. Test

More information

MODULES FOR SAFETY AND MONITORING

MODULES FOR SAFETY AND MONITORING MODULES FOR SAFETY AND MONITORING Woertz AG Hofackerstrasse 47, P.O. Box 948, CH-43 Muttenz, Switzerland Tel. ++4 6 / 466 33 33, Fax ++4 6 / 46 96 06 http://www.woertz.ch Woertz-USA 5 Discovery Drive,

More information

DC M2 OLED Meter Instructions PN 1830 / PN 1832 / PN 1833 / PN 1834

DC M2 OLED Meter Instructions PN 1830 / PN 1832 / PN 1833 / PN 1834 DC M2 OLED Meter Instructions PN 1830 / PN 1832 / PN 1833 / PN 1834 Installation Checklist Check for components included Read Warning and Cautions Read QuickStart Installation Guide for mounting instructions

More information

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING

Product and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.

More information

IIM Warwick Court. Williamsburg VA REV 5

IIM Warwick Court. Williamsburg VA REV 5 1 1-757-258-3939 100 Warwick Court Williamsburg VA 23185 REV 5 2 Technical Specification >Accuracy Better than + 1% over a range of 1.5 to 200 amperes with power factor ranging from 1 to 0.5 Approved by

More information

Conductive Sensors 2 to 4-point level controller Type CL with teach-in

Conductive Sensors 2 to 4-point level controller Type CL with teach-in Conductive Sensors to 4-point level controller Type CL with teach-in Conductive level controller Teach-in of sensitivity operating resistance from 0Ω to 0KΩ Multiple combinations of filling and emptying

More information

AS-i Safety Analog Input Module, IP20

AS-i Safety Analog Input Module, IP20 2 safe inputs in one module: 4... 20 ma or 0... 10 V or Pt100 or thermocouple (type J / K / N / R / S) Applications up to category 4/PLe/SIL 3 (figure similar) The AS-i Safety Input Module for analog inputs

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

AC Power Management field for 20 years Expanding to Complement and Protect DSP Processors, Amplifiers, and IP Products Innovation, Protection,

AC Power Management field for 20 years Expanding to Complement and Protect DSP Processors, Amplifiers, and IP Products Innovation, Protection, AC Power Management field for 20 years Expanding to Complement and Protect DSP Processors, Amplifiers, and IP Products Innovation, Protection, Convenience, Value Sequencers ETA-S15L 15A / 1800W Power Conditioning

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels 4 additional analog

More information

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED

Indicating Digital Transmitter for Differential Pressure and Flow. Media 6 with LCD Media 6 with LED Indicating Digital Transmitter for Differential Pressure and Flow Media 6 with LCD Media 6 with LED Application Microprocessor-controlled transmitter for measuring and indicating the differential pressure

More information

Circuit Breaker Analyzer & Timer CAT65

Circuit Breaker Analyzer & Timer CAT65 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773

DATASHEET ULTRASONIC COMPACT ENERGY METER MODEL 773 APPLICATION Static compact energy meter using ultrasonic technology Highly accurate recording of all billing data in local and district heating and cooling systems FEATURES 1st. approval in Europe for

More information

Matrix printer uni-bit. Application areas

Matrix printer uni-bit. Application areas Technical information TI 026R/09/e/5.95 Mat.-Nr. 500 51401 Matrix printer uni-bit IBM compatible maintenance free compact printer, with internal paper cassette Application areas The Uni-Bit compact printer

More information

Albatross Control System Installation

Albatross Control System Installation Albatross Control System v1.4 Albatross Control System Installation PRELIMINARY Rev.PA1 No part of this document may be reproduced in any form without the written permission of the copyright owner. The

More information

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC

Article no. BWU2045: AS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input 1.23 NC Safety + standard I/O in one module AS-i Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category

More information

Circuit Breaker Analyzer & Timer CAT66

Circuit Breaker Analyzer & Timer CAT66 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

BEP 600-DCSM DC SYSTEMS MONITOR. Installation and Operating Instructions. INST-600-DCSM-V1 Page 1

BEP 600-DCSM DC SYSTEMS MONITOR. Installation and Operating Instructions. INST-600-DCSM-V1 Page 1 BEP 600-DCSM DC SYSTEMS MONITOR Installation and Operating Instructions INST-600-DCSM-V1 Page 1 This page has been deliberately left blank INST-600-DCSM-V1 Page 2 Table of Contents 1. BASICS 4 Features

More information

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection

4.8 Digital Input/Output Module 07 DC 92 Contents Intended purpose Displays and operating elements on the front panel Electrical connection 4.8 Digital Input/Output Module 07 DC 9 3 configurable digital inputs/outputs, 4 V DC, electrically isolated in groups, outputs can be loaded with 500 ma, CS31 system bus 1 3 4 1 Fig. 4.8-1: Digital input/output

More information

Handheld Micro Ohmmeters RMO-H series

Handheld Micro Ohmmeters RMO-H series Handheld Micro Ohmmeters RMO-H series Handheld only 0,95 kg / 2.1 lbs Powerful regulated current up to 300 A DC Automatic test current ramp Operated by high-capacity battery Measuring range 0,1 μω 2000

More information

Expansion Module HZS 541-1S

Expansion Module HZS 541-1S Expansion Module HZS 541-1S 12.10.2015 Page 1 System Description The external HZS 541-1S expansion module provides users of biomass heating systems with additional 230 V AC relay outputs, analog inputs

More information

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance

PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance PU5 5-digit digital panel meter in 96x48 mm (BxH) Universal measuring inputs: Pt100, current, voltage, shunt, thermocouple, resistance red display of -9999 99999 digits installation depth: 120 mm without

More information

IB080QM65VA3 Part Number

IB080QM65VA3 Part Number Inductive Proximity Switch with increased Switching Distance IB080QM65VA3 Part Number Technical Data Inductive Data Switching Distance 8 mm Correction Factors V2A/CuZn/Al 0,93/0,40/0,36 quasi-flush A/B/C/D

More information

DEEP SEA ELECTRONICS PLC

DEEP SEA ELECTRONICS PLC COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE705 ATS CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723

More information

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply

96x48. gal/h. Digital panel meter 4½-digit DV4. Without setpoints. Sensor supply gal/h Digital panel meter 4½digit DV4 Without setpoints Sensor supply status 22/05/06 panelmeteranalog_gb.doc page 9 Digital panel meter Direct voltage Direct current gal/h Direct voltage, direct current

More information

Chassis Power Supplies

Chassis Power Supplies PDC24 / PAC Chassis Power Supplies (PDC24 / PAC) Issue 3 October 2005 INTRODUCTION PURPOSE Two Power Supply Units (PSUs) provide a dual-redundant source of 5.4Vand 12Vdc onto the backplane for the modules

More information

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL

ISO 9001 CERTIFIED. 607 NW 27th Ave Ocala, FL Phone: (352) or Fax: (352) OPERATION MANUAL ISO 9001 CERTIFIED Phone: (352) 629-5020 or 800-533-3569 Fax: (352)-629-2902 ES-Key 18 Input module (selectable polarity) with 3 outputs (selectable polarity) with 1 analog (selectable 0-5V or 4-20mA)

More information

E-Series General Specifications

E-Series General Specifications -Series General Specifications Ideally suited for higher amperage applications. Available with front and back mounting, screw terminals, stud terminals and heavy duty box wire connectors for solid wire

More information

with Backlight Graphic LCD Screen

with Backlight Graphic LCD Screen with Backlight Graphic LCD Screen ENERGY AND AUTOMATION POWER OF ENERGY SAVING For the control of energy distribution systems detecting when problems occur that could put the quality and availability of

More information

Central Battery System ZB-S Eaton, All Rights Reserved.

Central Battery System ZB-S Eaton, All Rights Reserved. Central Battery System ZB-S Central Battery System ZB-S Agenda New charging technology System Configuration Internal Modules External Modules Battery Management System PC Software CG Vision Date, Venue

More information

- Ovens - Food processing - Dryers, etc.

- Ovens - Food processing - Dryers, etc. Built-In Temperature Controllers Single channel temperature controllers for use in: - Hot runner applications - Machines for plastics processing - Packaging machines - Ovens - Food processing - Dryers,

More information

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

I need to protect my equipment against damaging power surges and spikes.

I need to protect my equipment against damaging power surges and spikes. Complex Problems I need a fail safe way to distribute clean power to my system. I need to protect my equipment against damaging power surges and spikes. I need a way to both monitor my electrical system

More information

Power System Network Simulator (PSNsim)

Power System Network Simulator (PSNsim) The PSNsim is hardware simulator that simulates all parts of power system from generation to utilization. The PSNsim is a scaled down model of the real power system that provides an experimental environment

More information

Miniature Circuit-Breaker IEC Series 8562

Miniature Circuit-Breaker IEC Series 8562 > 1 to 3 pole versions > Rated current from 0.5... 40 A > 6 or 10 ka breaking capacity to DI VDE 0641, respectively E 60898 > Isolating Function to E 60947-2 > Permanently set thermal and magnetic trips

More information

UH28C. High Voltage Tester. Product Information Sheet V AC / 100 ma

UH28C. High Voltage Tester. Product Information Sheet V AC / 100 ma UH28C High Voltage Tester 5 000 V AC / 100 ma Product Information Sheet Short summary - overview Item number 200366 Test voltage Test current, limit Power 100 5 000 V AC, 0,5-100 ma > 500 VA Short circuit

More information

PDU Solutions. PDU Solutions

PDU Solutions. PDU Solutions Canovate offers a full range of PDU s from basic and metered ones to IP PDU s with per socket switching capability and wireless sensor connectivity. Our PDU s can be used in the most complex ISP and Colocation

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

ECL Comfort V a.c. and 24 V a.c.

ECL Comfort V a.c. and 24 V a.c. Data sheet ECL Comfort 200 230 V a.c. and 24 V a.c. Application The ECL Comfort 200 electronic controller is pre-programmed for a variety of different applications. Each application has its own card describing

More information

topter SERIES ACTIVE PROTECTION Leading Electrotechnology

topter SERIES ACTIVE PROTECTION Leading Electrotechnology topter SERIES ACTIVE PROTECTION Leading Electrotechnology topter series Active protection Industrial sockets splash proof and watertight IP44, IP66/IP67 product specifications Conformity to standards EN

More information

ML17 Series Tru-Vue TM Sensors

ML17 Series Tru-Vue TM Sensors ML7 Series Tru-Vue TM Sensors Diffuse Mode with Background Suppression See page 44 Features: Ver low color sensitivit Tamper-proof housing with no eternal adjustments Sensing Range: 5 mm Output: 4-in-

More information

JUMO Quantum PID100/PID200/PID300

JUMO Quantum PID100/PID200/PID300 Data sheet 702020 Page 1/12 JUMO Quantum PID100/PID200/PID300 Universal PID Controller Series Brief description The Quantum series is available in the three DIN formats 48 mm x 48 mm, 48 mm x 96 mm, and

More information

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature

JUMO ecotrans ph 03 Microprocessor transmitter/ switching device for ph/redox voltage and temperature Page 1/7 JUMO ecotrans 03 Microprocessor transmitter/ switching device for /Redox voltage and temperature with a 2-line LCD for mounting on a 35 mm DIN rail Brief description Depending on the configuration,

More information

Wireless DMX Control. Show Performer DMX Controller. Stage Desk 48 DMX Controller

Wireless DMX Control. Show Performer DMX Controller. Stage Desk 48 DMX Controller Wireless DMX Control SRC-260 Each unit is a transmitter and receiver based on its Dip settings. Connect a DMX 512 standard controller to the SRC-260 and set another SRC-260 set in receivers mode down range

More information

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing

ADVANCED ultrasonic sensors with 2 switching outputs. Dimensioned drawing Dimensioned drawing en 2-214/2 5124879 25 4mm 15 13mm 15-3 V DC We reserve the right to make changes DS_HTU418BX3LT4_en_5124879.fm Largely surface-independent function, ideal for the detection of liquids,

More information

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL Technical documentation LIGHT CONTROL PANEL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition Page 1 of 26 Table of contents 1. Application and

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data:

Instruction Manual. M Pump Motor Controller. For file reference, please record the following data: Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your

More information

10~96W Miniature Single Output. 105%~160% constant current limiting, auto-recovery

10~96W Miniature Single Output. 105%~160% constant current limiting, auto-recovery 10~96W Miniature Single Output MDR-10 MDR-20 MDR-40 Installed on DIN rail TS-35 / 7.5 or 15 Over voltage No load power consumption

More information

Operator's manual 4000 Instrumentation en-gb Issue 1.0

Operator's manual 4000 Instrumentation en-gb Issue 1.0 Operator's manual 4000 Instrumentation en-gb 2 268 463 Issue 1.0 Preface................................ 3 Functions.............................. 3 Instrument panel........................ 5 Display navigation.......................

More information

Immersion Temperature Sensors

Immersion Temperature Sensors 1 782 1782P01 Symaro Immersion Temperature Sensors QAE2164 QAE2174 Active sensors for acquiring the water temperature in pipes and tanks Operating voltage AC 24 V or DC 13535 V Signal output DC 010 V or

More information

Installation Instructions Temperature transmitter TAA /00 06/2011

Installation Instructions Temperature transmitter TAA /00 06/2011 Installation Instructions Temperature transmitter TAA431 706042/00 06/2011 Contents 1 Functions and features...3 2 Installation...4 2.1 Addressing...4 2.2 Mechanical installation...4 2.3 Connection to

More information

Calder Centaur Workshop Manual

Calder Centaur Workshop Manual Calder Centaur Workshop Manual Revision: 04-03-2013 Covers all Calder Centaur electrofusion units incorporating the following circuit boards: CVTE0030 Issue 9 Power Board CVTE0034 Issue 9 Control Board

More information

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field

DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION. Application field DGSZV-EP DIGITAL GALVANIC LONGITUDINAL DIFFERENTIAL PROTECTION The digital galvanic longitudinal differential protection of type DGSZV-EP is part of device family named EuroProt. This short description

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Linear Position Transducer HLT 1000-R2

Linear Position Transducer HLT 1000-R2 Linear Position Transducer HLT 1000-R2 Description: The sensor works on the principle of magnetostriction. This measuring principle determines with high accuracy the position, distance and/or speed and

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

GPM500 Generator Protection Module

GPM500 Generator Protection Module GPM500 Generator Protection Module Generator Protection Module GPM500 The microprocessor based Generator Protection System GPM500 performs the protection and control of medium and low voltage generators

More information

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories Mini Clamps: Part Number 111.7015 PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories Description 10 ma-to-20 A or 100 ma-to-200 A. Switchable range mini clamp. 40 Hz 20 khz 4 x mini

More information

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318

ATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318 ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16

More information

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A.

AThink future. Switch to green. Mini Panel Board. Cost-effective, space-saving board up to 400A. www.moeller.co.uk Mini Panel Board Cost-effective, space-saving board up to 400A Product Catalogue and Selection Guide Mini Panel Board Miniature Circuit Breakers Moulded Case Circuit Breakers XBoard Consumer

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors

MULTI 9 System Catalog UL Recognized C60N Supplementary Protectors UL Recognized C60N Supplementary Protectors B Curve C60N Supplementary Protectors 1 MG24110 MG24125 MG24140 MG24155 15 MG17406 MG17436 MG17461 1.2 MG17402 MG17432 16 MG24118 MG24133 MG24148 MG24163 1.5

More information

N+1 DC Power System with Battery Backup / Charging Function

N+1 DC Power System with Battery Backup / Charging Function MODULAR 24V DC POWER SUPPLY N+1 DC Power System with Battery Backup / Charging Function MODEL : SPS-2450B Please read this manual before operating your power supply. INSTALLATION & OPERATING MANUAL PROVIDES

More information

78 Series Electromechanical Relay Selection Guide

78 Series Electromechanical Relay Selection Guide 78 Series Electromechanical Relay Selection Guide Specification 781 Series 782 Series 783 Series 784 Series Coil Voltages Configuration SPDT DPDT 3PDT 4PDT Contact Rating 15A 15A 15A 15A Base Socket 5

More information

Data sheet CC 03, Commander Compact (603-1CC21)

Data sheet CC 03, Commander Compact (603-1CC21) Data sheet CC 03, Commander Compact (603-1CC21) Technical data Order. Type 603-1CC21 CC 03, Commander Compact General information Note - Features Display: 2 x 20 characters Interface: MP²I User memory:

More information

RoHS. High shaft load capacity. Shock / vibration resistant

RoHS. High shaft load capacity. Shock / vibration resistant Due to their sturdy bearing construction in Safety-Lock Design, the Sendix 5000 and 5020 offer high resistance against vibration and installation errors. The rugged housing, high protection level of up

More information

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020

Selection Guide. Control Circuit and Load Protection. Allen-Bradley 1489-M2C020 Selection Guide Control Circuit and Load Protection Circuit Protection Portfolio 1489-M Circuit Breakers Approved for branch circuit protection in the United States and Canada, and certified as Miniature

More information

DC UPS Systems. Powering IIoT. Site Power Monitor. DC Power Accessories. ADP Vol 1

DC UPS Systems. Powering IIoT. Site Power Monitor. DC Power Accessories. ADP Vol 1 DC UPS Systems Powering IIoT Site Power Monitor DC Power Accessories ADP Vol 1 DIN-Rail DC UPS Powers Loads and Charges Back-Up Battery, Ideal for Automation and Wireless System Transmitter Applications

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR

MSR Level Control Relay Module Operating Instructions for Level Control Relay Module Model: MSR Operating Instructions for Level Control Relay Module Model: MSR MSR Operation Instructions Rev. Apr 07 Page 1/8 1. Note Please read and take note of these operating instructions before unpacking and commissioning.

More information

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A

3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A 3,600 W to 10,800 W 120 V to 800 V 22.5 A to 330 A 2 Electronic Energy Recycling Load ERI Series Syntax Interface Overview RS-232 USB LAN GPIB O CAN Analog Analog isolated O Standard O Option /not available

More information

AC M2 OLED Meter Instructions PN 1836/ PN 1837 / PN 1838

AC M2 OLED Meter Instructions PN 1836/ PN 1837 / PN 1838 AC M2 OLED Meter Instructions PN 1836/ PN 1837 / PN 1838 Installation Checklist Check for components included Read Warning and Cautions Read QuickStart Installation Guide for mounting instructions Read

More information

PRODUCT. Battery Charger

PRODUCT. Battery Charger PRODUCT Battery Charger Model : BC 9080 Battery Charger The ICD Battery Charger is designed to supply required DC Voltage and Current to the connected load and recharge the Battery on boost charging over

More information

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Miniature Hydraulic/Magnetic Circuit Breaker M-Series M-Series PDF elibrary The M-Series miniature hydraulic/magnetic circuit breakers

More information

Plug in to external instrument, lamp or buzzer

Plug in to external instrument, lamp or buzzer Document version 3.1, March 2009 Gobius 4, Waste Holding Tanks Installation Guide Before you begin 1. Please make sure that no parts are missing. (3 sensors, 1 panel, 1 control unit (091427), 1 3M cleaning

More information

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY.

OWNER'S MANUAL. Model:PSV Amp SWITCHING DC POWER SUPPLY. OWNER'S MANUAL Model:PSV-40 3-Amp SWITCHING DC POWER SUPPLY www.pyramidcaraudio.com FEATURES Your PYRAMID Heavy-Duty 3-Amp Switching DC Power Supply is designed to use AC power-to-power equipment that

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X 1. Use of the option modules There are two different housings with which these same plug-in units can be used namely: Calculator housing 1 (PolluTherm, PolluStat E and PolluFlow 2010) indicated by a lid

More information

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers

Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Products :: Circuit Protection :: Hydraulic/Magnetic Circuit Breakers Hydraulic/Magnetic Circuit Breaker B-Series B-Series PDF elibrary The B-Series hydraulic/magnetic circuit breakers are compact and

More information

Capi2 Trainings manual

Capi2 Trainings manual CAPI2 BV NETHERLANDS Capi2 Trainings manual Distributed power systems Get into the bus... CAPI2 BV N ETHERLANDS Spegelt 29 5674CE Nuenen Netherlands Tel: 0031 40 2847001 Fax: 0031 40 2834101 E-mail: info@capi2.com

More information

Installer manual. Eikon Arké Plana BUS EnOcean interface - 2 modules

Installer manual. Eikon Arké Plana BUS EnOcean interface - 2 modules Installer manual Eikon 20508 Arké 19508 Plana 14508 BUS EnOcean interface - 2 modules Instructions This manual is necessary in order to configure the radio-frequency devices when used with the By-me automation

More information

Installer manual. Eikon Arké Plana BUS EnOcean interface - 2 modules

Installer manual. Eikon Arké Plana BUS EnOcean interface - 2 modules Installer manual Eikon 20508 Arké 19508 Plana 14508 BUS EnOcean interface - 2 modules Instructions This manual is necessary in order to configure the radio-frequency devices when used with the By-me automation

More information

MTeC - EPT202 Digital thermometer Messko

MTeC - EPT202 Digital thermometer Messko www.messko.de MTeC - EPT202 Digital thermometer Messko MTeC -EPT202 the all-roundermto ST160 und MTO STF 160 The main functions such as Power, Alarm, Trip, Error and the operating status of the individual

More information

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp

IMS Control & EPR, We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp IMS Control & EPR, 2010 01 29 We keep your motors running ABB s new control & protection devices up to 18.5 kw / 20 hp October 27, 2010 1SBC101089D0201 ABB s new control and protection devices Up to 18.5

More information

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3

Wiring diagrams. Content. Information for reading and graphic symbols... 5/2. Wiring diagrams of the circuit-breakers... 5/3 Wiring diagrams Content Information for reading and graphic symbols... 5/2 Wiring diagrams of the circuit-breakers... 5/3 Electrical accessories... 5/4 5/1 Information for reading and graphic symbols State

More information

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers

DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations

More information

Digital Positioner 8049

Digital Positioner 8049 Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air

More information

MODEL 9250 Preliminary data sheet

MODEL 9250 Preliminary data sheet Delivery: ex stock Warranty: 24 months Universal Instrumentation Amplifier for strain gage, potentiometric, DC/DC and incremental sensors MODEL 9250 Preliminary data sheet NEW burster TEDS Highlights Ultra-fast

More information