1 Raytheon Anschütz GmbH Postfach 1166 D Kiel Germany Tel Fax Service@raykiel.com -anschuetz.de Remote NFU Tiller Type E/ DOC012 Revised: 22. January 2003 Revised: March 16, 2007

2 Weitergabe sowie Vervielfältigung dieser Unterlage, Verwertung und Mitteilung ihres Inhaltes nicht gestattet, soweit nicht ausdrücklich zugestanden. Zuwiderhandlungen verpflichten zu Schadenersatz. Toute communication ou reproduction de ce document, toute exploitation ou communication de son contenu sont interdites, sauf autorisation expresse. Tout manquement à cette règle est illicite et expose son auteur au versement de dommages et intérêts. Copying of this document, and giving it to others and the use or communication of the contents thereof, are forbidden without express authority. Offenders are liable to the payment of damages. Sin nuestra expresa autorización, queda terminantemente prohibida la reproducción total o parcial de este documento, así como su uso indebido y/o su exhibición o comunicación a terceros. De los infractores se exigirá el correspondiente resarcimiento de daños y perjuicios.

3 TABLE OF CONTENTS Page 1 General Remote NFU Tiller in Steering Control System Notes to operating instructions Switching on General Standard operation Additional controls in standard operation Illumination control Testing Warnings Faulty operation Annex: Control and display devices I 3430E/ DOC012

4 3430E/ DOC012 II

5 1 General Installed on a control panel or on a navigating stand, the Remote FU Tiller is used on the bridge to serve as a time control element (NON FOLLOW UP). In order to switch control lever to PORT or STBD up to the mechanical end, a switch contact is closed. These operating instructions contain every operational procedure as well as information about behaviour when alarms occur. Such alarms are indicated on the digital display units and also by means of flashing LEDs and audible alarm signals. Service manual In addition to the operating manual, there is also a service manual. It contains the following: -- Information relating to installation and initial start-up. -- Information relating to maintenance and repairs, and -- a description of the tiller E/ DOC012

6 2 Remote FU Tiller in Steering Control system Remote NFU tillers are bus users on the user device bus (BG bus) *) on the NP 2000 autopilot control transmitter within a secondary steering system. The remote NFU tiller is activated by setting the steering mode selector either to the REMOTE or the AUTO/REMOTE setting (see figure). The bus transfers the control signals, and the NP2000 Autopilot Control Unit converts these into analogue control signals for the NFU amplifier. The control point can be selected on site. The selection is made according to the Take Over principle, i.e. only one control point is active. A total of 15 bus users can be connected (including bus tillers of different designs). Steering mode selector Remote NP 2000 Autopilot FU--Amplifier Auto/Remote Analog set rudder value signal BG--Bus *) Max. 15 bus users NFU Tiller PORT Wing NFU Tiller STBD Wing *) specific to Raytheon Marine Remote NFU Tiller in Steering Control system 3430E/ DOC012 2

7 3 Notes to operating instructions The system operates interactively (i.e. an action causes a reaction). Each operating procedure shown must be completed step by step. Where necessary and in the relevant sections, we have added useful supplementary notes alongside the illustrations (symbols). We recommend that you fold out the appendix page since it contains an illustration of all the controls and indications. Explanation of the symbols used. press a key LED off LED on LED flashing audible signal on audible signal off E/ DOC012

8 4 Switching on When the full rudder control system is switched on, the remote NFU tiller is also ready for operation in REMOTE or in AUTO/REMOTE mode. 4.1 General Indications Comments Notes For example: red The display is indicating the current rudder angle in, the relevant LED is illuminated. If the final decimal point of the indicated figure is illuminated, this means that an additional 0.5 is being indicated. In the example: 10,5 Rudder position is indicated by illuminating the relevant LED (PORT is red, STBD is green). Both LEDs remain unlit when the rudder position is 0 It is possible to have two different system configurations: a) The NFU tiller can only be used in REMOTE operating mode. b) In AUTO/REMOTE operation mode, it is possible to switch between NFU tiller and autopilot operation without activating the steering mode selector. 3430E/ DOC012 4

9 5 Standard operation Indications Comments Notes Tiller in Version a: Set steering mode selector to REMOTE After switching to REMOTE the rudder is steered manually by means of the hand wheel until a tiller is activated. The standby LED beside the / key is illuminated Version b: Steering mode selector is set to AUTO/REMOTE After switching to AUTO/REMOTE the rudder is steered manually by means of the hand wheel until a tiller is activated. The standby LED beside the / key is illuminated Activate tiller green Press the / key An audible signal sounds when the switch is made The active LED beside the key is illuminated. Autopilot: For example: red Tiller Steering The line of text on the autopilot control unit indicates manual steering. Turn lever (Joystick) to set the required rudder angle The display unit indicates the actual rudder angle in and the relevant LED is illuminated E/ DOC012

10 Indications Comments Notes Deactivating the tiller 1. Switch the steering mode selector to main FU steering system or NFU Autopilot: Heading Control other tiller or 2. Return control system to autopilot: Activate a function key (e.g. HEADING ) on the autopilot (see system configuration) or 3. activate another tiller The LED beside the deactivated tiller is illuminated. 6 Additional operation in standard operation 6.1 Illumination control Indications Comments Notes Increases the brightness on all LEDs and Indications. Decreases the brightness on all LEDs and Indications. 3430E/ DOC012 6

11 6.2 Testing Indications Comments Notes Automatic test cycle lasting approx. 30s. simultaneous Approx. 2 second check of -- 7 segment display -- audible signal (twice) -- LEDs to maximum brilliance -- key illumination to maximum brilliance The following indications are then tested: -- Tiller type NON Follow-Up (nf) For example: -- Bridge assignment for example: Tiller on bridge 1 (b1) -- Rudder scale in two steps -- indication (rs) For example: For example: -- Rudder scale value for example: Software version in three steps -- E For example: -- the DP address in two steps -- bus user address (Ad) -- value e.g current status of bus termination e.g. RS485 interface is not terminated ( t1 is terminated) Locations: Pn = Port Wing Sn = Starboard Wing br = Bridge (1) bb = Bridge (2) or -- Indication of installation--position (also in case of external control) Fr = External control possible (External control must not be installed) Po = Position ---- = not already adjusted Edition: 22. January E/ DOC012

12 Indications Comments Notes For example: -- the EPROM checksum in three steps, e.g. A3 EB -- check sum (CH) -- upper hexadecimal value -- lower hexadecimal value When the test has ended the display automatically reverts to indicating the rudder position 6.3 Warning messages Warning messages occur if the remote NFU tiller is activated without previously activating tiller control, which means that steering control is ineffective from this tiller. Indications Comments Notes Steering mode selector to AUTO Version a: Steering mode selector is set to Auto Version a (see section 4): Neither LED (ACTIVE or STANDBY) is lit Version b: Version b (see section 4): The STANDBY LED is illuminated When the tiller is moved a pulsed audible warning signal (5 separate tones) sounds. Steering mode selector to REMOTE tiller in STANDBY 3430E/ DOC012 8 Edition: 22. January 2003

13 Indications Comments Notes Steering mode selector is set to Remote The STANDBY LED is illuminated. When the tiller is moved a pulsed audible warning signal (5 separate tones) sounds. Steering mode selector to NFU Steering mode selector is set to NFU Neither LED (ACTIVE or STANDBY) is lit When the tiller is moved a pulsed audible warning signal (5 separate tones) sounds. Steering mode selector to FU Steering mode selector is set to FU Neither LED (ACTIVE or STANDBY) is lit When the tiller is moved a pulsed audible warning signal (5 separate tones) sounds E/ DOC012

14 7 Faulty operation Behaviour when alarms occur: red -- When an alarm occurs: and -- acknowledge alarm by pressing: The audible alarm stops, the LED is illuminated. The light remains on permanently until the fault is rectified -- Steering mode selector to AUTO or to FU (Follow--up) No. indication Meaning Likely cause 1 BG bus error *) -- Short circuit -- Faulty cable -- Faulty tiller 2 Steering failure Steering control faulty Reference parameters for set rudder turning rate not set correctly Effect on operation The tiller cannot be used The tiller cannot be used, if the rudder does not follow the set values The tiller can be used if it is only the monitoring parameter that is incorrectly adapted. Measures to take -- Switch steering mode selector from Auto or Remote to FU or NFU -- check the cable connection -- disconnect the faulty device from the bus -- Set steering mode selector to MANUAL -- inform Raytheon Anschütz -- Set steering mode selector to MANUAL -- adapt the parameter check parameter RdSpeed (adjustable at Autopilot)** -- inform Raytheon Anschütz 3 Tiller fault Defect in bus tiller The tiller cannot be used -- Switch steering mode selector from Auto or Remote to FU or NFU -- change tiller control point 4 Configuration fault -- Incorrect value -- Values outside valid range Values not adopted, but bus tiller operation is not disturbed Check the configuration (see service manual) *) specific to Raytheon Anschütz **) Rudderturning rate not correct adjusted (parameter setting 1 at the Autopilot meets a rate of 1 /s). If the error E2 occurs an adjustment of either 0 or a higher setting than 1 for RdSpeed (Rudder Speed) must be selected System configuration, Operator Unit Autopilot. 3430E/ DOC Edition: March 16, 2007

15 No. indication Meaning Likely cause Effect on operation Measures to take 5 1*) For Dual Follow-up devices the second device for independent operation is missing -- The second device is incorrectly configured -- The second device is not connected Independent operation not possible Only synchronous steering possible! Check bus connection to second device 6 1*) EEPROM faulty Defective EEPROM The tiller cannot be used -- Switch steering mode selector from Auto or Remote to FU or NFU -- Change tiller control point -- Inform Raytheon Marine 7 Unknown tiller type Hardware fault Tiller not operating -- Switch steering mode selector from Auto or Remote to FU or NFU -- Change tiller control point -- Inform Raytheon Marine 8 No tiller telegrams -- No bus connection The tiller cannot be used -- Switch steering mode selector from Auto or Remote to FU or NFU -- Faulty device -- Change tiller control point -- Check bus connection (check data cable) -- Inform Raytheon Marine 1*)Once the E2 and E5 alarms have been acknowledged the display returns to standard indication of the rudder position, making it possible once again to change the rudder angle. The luminous alarm diode changes from flashing to permanently lit and remains illuminated until the fault has been rectified. If the alarm key is pressed the error code can be retrieved into the display for the time that the key is pressed E/ DOC012

16 3430E/ DOC012 12

17 7 segment indicator actual indication in current parameter Alarms STBD LED (green) Alarm signal and acknowledgement (red LED) Indication Rudder command Tiller NFU PORT LED (red) NFU Lever (Joistic) Tiller active LED (green) Tiller LED () Tiller activation Brightness control infinitely variable brightness control Testing a check is made of -- the 7 segment indicator -- the audible alarm -- the LEDs to maximum brightness -- Key illumination to maximum brightness -- current parameters Control and display devices Edition: 4 Aug 00 Annex1 3430E/ DOC012

18 Short-form operating instructions Tiller type Steering mode selector Edition: 22. January 2003 Tiller group for remote and override operation Activation and operation indication Deactivation Comments E/ DOC022 Remote NFU Tiller Type Version a: green see description no. 3430E/ DOC012 Remote FU Tiller Type Version b: two devices required Type e.g. green green 1. Switch steering mode selector to main FU steering systemor NFU see description no. 3431E/ DOC STBD or green Synchronous green Independent green Synchronous green red e.g. 10 PORT Rudder position 0 red e.g. Autopilot: 2 control system returned to After switching to REMOTE or Heading Control other tiller 2. control system returned to autopilot: activate a function key (e.g. HEADING ) on theautopilot (system configuration) or 3. activate another tiller After switching to REMOTE or AUTO/REMOTE on the steering mode selector the rudder is steered manually until a tiller is activated. see description no. 3434E/ DOC012 Both rudders One rudder only Both rudders 10,5 PORT Autopilot: Tiller Steering Autopilot Override NFU Tiller Remote FU Tiller (Dual) Type Type green 1. Switch steering mode selector to main FU steering system or NFU Neither LED is lit see description no. 3432E/ DOC012 green Autopilot: or Override Auto 2. press the AUTO key Steering control is taken over by the autopilot see description no. 3433E/ DOC012 Dimming Testing Autopilot Override FU Tiller or Infinitely variable brightness control for all LEDs and indicators. simultan-- eous Automatic Testing cycle lasting aprox. 30s - 7 segment indication - audible signal - LEDs - key illumination Tiller type Assignment of bridge Group to which it belongs Rudder scale Software version DP address For example: For example: For example: Bus termination For example: Position f. example: check sum for FU Tiller (dual) only For example: For example: For ex.: t1 = terminated t0 = not terminated Fr=Remote control Po=Position For example:

19 Warning messages Warning messages occur if the remote FU tiller (dual) is activated without previously activating tiller control, which means that steering control is ineffective from this tiller. Steering Indications Confirmation/reaction mode selector Steering mode selector to AUTO Comments Notes Version a: Does not apply to Autopilot Override Tiller! or When the tiller is moved Version b: pulsed audible warning signal See section 4 of the relevant device description for versions a and b. Steering mode selector to REMOTE tiller in STANDBY or When the tiller is moved Autopilot Override Tiller: pulsed audible warning signal Steering mode selector to NFU or When the tiller is moved Autopilot Override Tiller: pulsed audible warning signal Steering mode selector to FU or When the tiller is moved Autopilot Override Tiller: pulsed audible warning signal Edition: March 16, 2007 Tiller group for remote and ovverride operation Faulty operation red When an alarm occurs: and ; acknowledge alarm with the audible alarm stops, the LED is permanently illuminated until the fault is rectified No. indication Meaning Likely cause Effect on operation Measures to take 1 BG bus error *) -- Short circuit -- faulty cable -- faulty tiller The tiller cannot be used -- Switch steering mode selector from Auto or Remote to FU ornfu -- Check the cable connection -- Disconnect the faulty device from the bus 2 Steering failure Steering control faulty See also sections of the manual entitled faulty operation or Troubleshooting The tiller cannot be used -- Switch steering mode selector from Auto or Remote to MANUAL -- See also sections in manual entitled Faulty Operation or Troubleshooting -- Check RdSpeed at theautopilot -- Inform Raytheon Anschütz 3 Tiller fault (Rudder adjustment only for Tiller , and ) Defect in bus tiller The tiller cannot be used -- Switch steering mode selector from Auto or Remote to FU ornfu -- Change tiller control point 4 Configuration fault -- Incorrect value -- Values outside validrange Values not adopted, but bus tiller operation is not disturbed Check the configuration (see service manual) 5 For dual follow-up devices the second device for independent operation is missing -- The second device is incorrectly configured -- The second device is not connected Independent operation not possible Only synchronous steering possible! Check bus connection to second device 6 EEPROM faulty Faulty EEPROM The tiller cannot be used -- Switch steering mode selector from Auto or Remote to FU ornfu -- Change tiller control point -- Inform Raytheon Anschütz 7 Unknown tiller type Hardware fault Tiller not operating -- Switch steering mode selector from Auto or Remote to FU ornfu -- Change tiller control point -- Inform Raytheon Anschütz 8 No tiller telegrams -- No bus connection -- Faulty device The tiller cannot be used -- Switch steering mode selector from Auto or Remote to FU ornfu -- Change tiller control point -- Check bus connection (check data cable) -- Inform Raytheon Anschütz *) specific to Raytheon Anschütz E/ DOC022

Autopilot Override NFU Tiller

Autopilot Override NFU Tiller Raytheon Anschütz GmbH Postfach 1166 D - 24100 Kiel Germany Tel+49-431-3019-0 Fax+49-431-3019-501 Email Service@raykiel.com www.raytheon -anschuetz.de Autopilot Override Type 105-302 3432E/105--302.DOC012

More information

DGR360. Digital Gyro Repeater. Operating & Installation Manual

DGR360. Digital Gyro Repeater. Operating & Installation Manual DGR360 Digital Gyro Repeater Operating & Installation Manual SKIPPER Electronics AS Telephone: +47 23 30 22 70 Enebakkveien 150 Telefax: +47 23 30 22 71 P. O. Box 151, Manglerud E-mail: support@skipper.no

More information

General Override Signal Unit AS (Operator Unit General Override)

General Override Signal Unit AS (Operator Unit General Override) RAnschütz Raytheon Anschütz GmbH Postfach 1166 D - 24100 Kiel Germany Tel +49-4 31-30 19-0 Fax +49-4 31-30 19-840 Email Service@raykiel.com www.raytheon-anschuetz.com General Override Signal Unit AS (Operator

More information

Take Over Operator Unit AS

Take Over Operator Unit AS RAnschütz Raytheon Anschütz GmbH Postfach 1166 D - 24100 Kiel Germany Tel +49-4 31-30 19-0 Fax +49-4 31-30 19-840 Email Service@raykiel.com www.raytheon-anschuetz.com Take Over Operator Unit AS Type 105-312

More information

Updating software in micro processors with internal Flash memory

Updating software in micro processors with internal Flash memory Raytheon Anschütz GmbH Postfach 1166 D 24100 Kiel Germany Tel +49 4 31 30 19 0 Fax +49 4 31 30 19 501 Email Service@raykiel.com www.raytheon anschuetz.de in Updating software in micro processors Operator

More information

AUTOPILOT NP 2025 PLUS

AUTOPILOT NP 2025 PLUS Raytheon Anschütz GmbH Postfach 1166 D - 24100 Kiel Germany Tel+49-431-3019-0 Fax+49-431-3019-501 Email Service@raykiel.com www.raytheon -anschuetz.de AUTOPILOT NP 2025 PLUS Type 102-886 NG005 OPERATOR

More information

Automatic Identification System AIS. Type RM 808 AIS. Short Operation Manual

Automatic Identification System AIS. Type RM 808 AIS. Short Operation Manual Raytheon Marine GmbH High Seas Products Postfach 1166 D - 24100 Kiel Germany Tel +49-4 31-30 19-0 Fax +49-4 31-30 19-291 Email Service@raykiel.com www.raytheon-marine.de Automatic Identification System

More information

Operator Unit. Type Description 2 Operation 3 Maintenance and repairs

Operator Unit. Type Description 2 Operation 3 Maintenance and repairs Raytheon Anschütz GmbH Postfach 1166 D - 24100 Kiel Germany Tel+49-431-3019-0 Fax+49-431-3019-501 Email Service@raykiel.com www.raytheon -anschuetz.de Operator Unit Type 1 Description 2 Operation 3 Maintenance

More information

Raytheon Anschütz GmbH Operator Manual

Raytheon Anschütz GmbH Operator Manual R Raytheon Anschütz GmbH Postfach 11 66 D - 24100 Kiel Germany Tel+49-431-3019-0 Fax+49-431-3019-464 Email service@raykiel.com www.raytheon -anschuetz.com Operator Manual 3464E100--037DOC012Edition: 18.DEC.2003

More information

Course to Steer Indicator (Operator Unit)

Course to Steer Indicator (Operator Unit) Course to Steer Indicator () Type 130-625 NG001 Raytheon Anschuetz GmbH Postfach 11 66 D-24100 Kiel Germany Tel +49-4 31-30 19-0 Fax +49-4 31-30 19 464 Email service@raykiel.com www.raytheon-anschuetz.com

More information

SINEC. Configuring the S7 Mode with COML S7. 1 Overview of S7 Communication. 2 The COML S7 Program. 3 Configuration. Volume 1 of 1.

SINEC. Configuring the S7 Mode with COML S7. 1 Overview of S7 Communication. 2 The COML S7 Program. 3 Configuration. Volume 1 of 1. SINEC Configuring the S7 Mode with COML S7 Volume 1 of 1 1 Overview of S7 Communication 2 The COML S7 Program 3 Configuration Glossary C79000-G8976-C074 Release 01 SINEC is a trademark of Siemens Siemens

More information

Modem for SITRANS TK 7NG3190-6KB C79000-B7174-C14 SIEMENS SITRANS TK COM 1 MODEM

Modem for SITRANS TK 7NG3190-6KB C79000-B7174-C14 SIEMENS SITRANS TK COM 1 MODEM Modem for SITRANS TK 7NG3190-6KB I ns t r uct i o n M a nua l SIEMENS 2 SITRANS TK MODEM COM 1 C79000-B7174-C14 SITRANS und SIPROM sind eingetragene Warenzeichen der Siemens AG. Die übrigen Bezeichnungen

More information

GDS101 Operation and Installation Manual

GDS101 Operation and Installation Manual Graphic Depth Sounder GDS101 Operation and Installation Manual Telephone: +47 23 30 22 70 Enebakkveien 150 Telefax: +47 23 30 22 71 P. O. Box 151, Manglerud E-mail: support@skipper.no 0612 Oslo, Norway

More information

PilotStar NX. Heading Control System

PilotStar NX. Heading Control System Heading Control System is the new autopilot from Raytheon Anschütz. Based on the experience of 6.000-installed PilotStar D s the well-known predecessor offers superior steering performance, which is now

More information

Weatherdock AG. Sigmundstraße D Nürnberg Tel. : Fax:

Weatherdock AG. Sigmundstraße D Nürnberg Tel. : Fax: Page 1 easytrx Link 2AIS SOFTWARE Class B AIS CS Transponder Produkt Nr.: A023 Rev-1 Weatherdock AG. Sigmundstraße D-90431 Nürnberg Tel. :+49 911 376 638 30 Fax: +49 911 376 638 40 www.weatherdock.com

More information

SIMATIC NET. AS-Interface Master Module CP Introduction. 2 Technical Description and Installation Guidelines for the CP 242-2

SIMATIC NET. AS-Interface Master Module CP Introduction. 2 Technical Description and Installation Guidelines for the CP 242-2 SIMATIC NET AS-Interface Master Module CP 242-2 Volume 1 of 1 1 Introduction 2 Technical Description and Installation Guidelines for the CP 242-2 3 Interface to the User Program 4 Standard Operation 5

More information

SkyRAY Light. Installation Handbook

SkyRAY Light. Installation Handbook Doc. No.: HB_0531_1000 Date: 2007-10-15 Issue: draft Release Notes Name Task Department Date Signature C. Hauff Creator 2007-10-15 Quality Management Review NDSQ Weitergabe sowie Vervielfältigung dieser

More information

SINEC. CP 5431 FMS with COM 5431 FMS. 1 Introduction C79000-B8976-C062/02. 2 Basics of the PROFIBUS B Index 3 Selecting the Type of

SINEC. CP 5431 FMS with COM 5431 FMS. 1 Introduction C79000-B8976-C062/02. 2 Basics of the PROFIBUS B Index 3 Selecting the Type of SINEC CP 5431 MS with COM 5431 MS Volume 2 of 2 1 Introduction C79000-B8976-C062/02 2 Basics of the PROIBUS B Index 3 Selecting the Type of Communication 4 Acyclic Communication with SINEC Services 5 Cyclic

More information

GDS101 Operation and Installation Manual

GDS101 Operation and Installation Manual Graphic Depth Sounder GDS101 Operation and Installation Manual SKIPPER Electronics AS Telephone: +47 23 30 22 70 Enebakkveien 150 Telefax: +47 23 30 22 71 P. O. Box 151, Manglerud E-mail: support@skipper.no

More information

SKIPPER DL Axis Doppler Log Operation And Installation Manual. Edition Csw3.26 Valid from SN: DOU-03137

SKIPPER DL Axis Doppler Log Operation And Installation Manual. Edition Csw3.26 Valid from SN: DOU-03137 SKIPPER DL850 2 Axis Doppler Log Operation And Installation Manual Edition 20050126Csw3.26 Valid from SN: DOU-03137 Skipper Electronics A/S Telphone +47 23 30 22 70 Ryensvingen 5 Telefax +47 23 30 22 71

More information

Velox. High-Speed Backplane Connectors for VPX

Velox. High-Speed Backplane Connectors for VPX High-Speed Backplane onnectors for VPX ontents Introduction 3 Technical Specifications 5 Hole Specifications 6 Velox High-Speed Backplane-onnector 7 Accessories: Guidings 9 2 ept GmbH I Tel. +49 (0) 88

More information

NAVITRON SYSTEMS LTD POWER STEER CONTROLS

NAVITRON SYSTEMS LTD POWER STEER CONTROLS NAVITRON SYSTEMS LTD POWER STEER CONTROLS NAVITRON SYSTEMS LTD (Registered in England 2607869) Osborn House, 25E Brockhampton Lane, Havant, Hampshire PO9 1JT TEL: (UK) 023 9249 8740 FAX: (UK) 023 9249

More information

MODEL K INSTRUCTION MANUAL CONTENTS

MODEL K INSTRUCTION MANUAL CONTENTS MODEL 7173 - K INSTRUCTION MANUAL CONTENTS 1. MODEL 7173 - K ELECTRONIC FFU STEERING SYSTEM 2. MODEL 7173 - K COMPONENTS 3. MOUNTING THE 7173 - K AMPLIFIER UNIT 4. MOUNTING THE FFU CONTROLLER UNITS 5.

More information

ACCX Air Conditioning

ACCX Air Conditioning ACCX Air Conditioning CMR Electrical Ltd Bolton House Five Chimneys Lane Hadlow Down East Sussex TN22 4DX Tel: 01825 733600 Run / Stand-by changeover Controller Installation and operation Manual 1 Two

More information

ComNav Marine Ltd. Phone: # Crestwood Place Fax:

ComNav Marine Ltd. Phone: # Crestwood Place Fax: ComNav Marine Ltd. Phone: 1-604-207-1600 #15-13511 Crestwood Place Fax: 1-604-207-8008 Richmond, BC E-mail:sales@comnav.com Canada V6V 2G1 Web: www.comnavmarine.com TYPE CT4 CONTROL BOX (Part # 20350003)

More information

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013

Device manual Profibus encoder. RM30xx RN30xx /00 06/2013 Device manual Profibus encoder RM30xx RN30xx 706355/00 06/2013 Contents 1 Preliminary note................................................. 4 1.1 Symbols used...............................................

More information

Option H8.x and H12.x External I/O modules Description of option Functional description

Option H8.x and H12.x External I/O modules Description of option Functional description MULTI-LINE DESCRIPTION OF OPTIONS Option H8.x and H12.x External I/O modules Description of option Functional description DEIF A/S Frisenborgvej 33 DK-7800 Skive Tel.: +45 9614 9614 Fax: +45 9614 9615

More information

MANUAL PCV Parameterization Tool

MANUAL PCV Parameterization Tool FACTORY AUTOMATION MANUAL Configuration software With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services

More information

EML224 / DL1 Compact Speed Log System

EML224 / DL1 Compact Speed Log System EML4 / DL1 Compact Speed Log System Operation and Installation Manual SKIPPER Telephone: +47 3 30 70 Enebakkveien 150 Telefax: +47 3 30 71 P. O. Box 151, Manglerud E-mail: support@skipper.no 061 Oslo,

More information

KNX DALI Gateway Plus - User Manual

KNX DALI Gateway Plus - User Manual KNX DALI Gateway Plus - User Manual Item No.: LC-013-064 1. Product Description The KNX DALI gateway Plus is the interface between the KNX installation and the DALI lighting system. It allows up to 64

More information

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions

1 Safety instructions. 2 Device components. 3 Function. DALI Tronic transformer 105 W. Order-No. : Operating instructions DALI Tronic transformer 105 W Order-No. : 2380 00 Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Failure to observe

More information

OT EASY 60 II. LED control unit Operating instructions

OT EASY 60 II. LED control unit Operating instructions II LED control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Intended use 4 Description... 5 Function and application 5 Function 5 Important definitions

More information

PULSE PIR Vers. IV. Light control. Operating Manual ENG

PULSE PIR Vers. IV. Light control. Operating Manual ENG Operating Manual Light control PULSE PIR Vers. IV Dear customer, these instructions apply in addition to the Lights Operating Manual. Observe in particular the safety instructions stated in the operating

More information

System manual AS-i safety monitor AC041S /00 05/2013

System manual AS-i safety monitor AC041S /00 05/2013 System manual AS-i safety monitor AC041S UK 7390926/00 05/2013 Contents 1 Preliminary note...4 1.1 Symbols used...4 2 Safety instructions...5 3 Items supplied...6 4 Functions and features...6 5 Structure

More information

BA688CF-F FOUNDATION fieldbus Panel mounting Display

BA688CF-F FOUNDATION fieldbus Panel mounting Display BA688CF-F FOUNDATION fieldbus Panel mounting Display Issue: 9 Issue: 9 6th June 2011 2 CONTENTS 1. Description 1.1 Documentation 1.2 Version 2.3 firmware 2. Operation 2.1 Controls 3. System Design 3.1

More information

SYNAPSIS NAUTOCONNING

SYNAPSIS NAUTOCONNING Anschütz Postfach 1166 D - 24100 Kiel Tel +49-4 31-30 19-0 Fax +49-4 31-30 19-840 Email sales@raykiel.com www.raytheon-anschuetz.com SYNAPSIS NAUTOCONNING SYSTEM MANUAL Version: E02.00 or higher 4347.DOC000002

More information

DALI Professional Controller-4. Control unit Operating instructions

DALI Professional Controller-4. Control unit Operating instructions LI Professional Controller-4 Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Configuration 5 Design 5 Connections

More information

PULSE PIR Vers. IV with MFT

PULSE PIR Vers. IV with MFT Operating Manual Control PULSE PIR Vers. IV with MFT Dear customer, these instructions apply in addition to the s Operating Manual. Observe in particular the safety instructions stated in the operating

More information

LY71. Instruction Manual (Operating manual) Counter Unit

LY71. Instruction Manual (Operating manual) Counter Unit Counter Unit Read all the instructions in the manual carefully before use and strictly follow them. Keep the manual for future references. Instruction Manual (Operating manual) Contents 1. Basic Operation...

More information

Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC1392

Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC1392 Supplementary device manual EtherCAT interface in the AS-i controllere A AC1391 AC139 firmware version RTS.x target from 15 for CoDeSys from version.3 English 739071_00_UK 01-0- Contents Revision: 16 December

More information

TR-1 Gold Basic Operation Guide PN

TR-1 Gold Basic Operation Guide PN TR-1 Gold Basic Operation Guide PN 906-2001-00 Version 061207 Remember safe and prudent operation of the vessel is your responsibility as Captain. How To Turn the Autopilot on: Press and release Deckmount

More information

Redundancy Concepts. INTRON-D plus. Single System with N+1 Components Duplicated Control System (hot stand-by operation) A+B System (shared operation)

Redundancy Concepts. INTRON-D plus. Single System with N+1 Components Duplicated Control System (hot stand-by operation) A+B System (shared operation) Redundancy Concepts INTRON-D plus Single System with N+1 Components Duplicated Control System (hot stand-by operation) A+B System (shared operation) THE ENGINEERS OF COMMUNICATION Optimum Protection -

More information

AP70/AP80 Operator Manual

AP70/AP80 Operator Manual AP70/AP80 Operator Manual ENGLISH navico.com/commercial Preface Disclaimer As Navico is continuously improving this product, we retain the right to make changes to the product at any time which may not

More information

High Voltage Power Supply (MMPS) - Troubleshooting Guide

High Voltage Power Supply (MMPS) - Troubleshooting Guide High Voltage Power Supply (MMPS) - Troubleshooting Guide LAST UPDATED: 09/19/2018 High Voltage Power Supply (MMPS) - Troubleshooting Guide Overview The High Voltage Power Supply (MMPS - MINIMILL Power

More information

LENGTH-ANGLE-RADIUS-LOAD INDICATING SYSTEM

LENGTH-ANGLE-RADIUS-LOAD INDICATING SYSTEM www.patamerica.com PAT America, Inc. LENGTH-ANGLE-RADIUS-LOAD INDICATING SYSTEM EI65/0005 OPERATOR S MANUAL P/N 056-065-190-005, Rev. C, 6/15/00 Operator s Manual EI65 / 0005 NOTICE The information in

More information

Users guide PB9648. Profibus Panelmeter 6-digit

Users guide PB9648. Profibus Panelmeter 6-digit Users guide PB9648 Profibus Panelmeter 6-digit Martens Elektronik GmbH Kiebitzhörn 18 D-22885 Barsbüttel Tel. +49(40)-670 73-0 Fax +49(40)-670 73-288 Status 04/07 / PB9648e.doc Contens 1. Brief description...3

More information

SIMOVERT MASTERDRIVES

SIMOVERT MASTERDRIVES SIMOVERT MASTERDRIVES Betriebsanleitung Operating Instructions SLE / SLE-DP SIMOLINK-Encoder Ausgabe / Edition: AA GWE-477 763 4070.76 J Änderungen von Funktionen, technischen Daten, Normen, Zeichnungen

More information

WARNING NOT ZTC Controls Ltd

WARNING NOT ZTC Controls Ltd WARNING If you fail to read the installation instructions properly it is possible that you could accidentally damage your ZTC unit. Such damage is NOT covered by our guarantee. So to prevent avoidable

More information

Operation and Settings of CPU & Power Modules, series 9440

Operation and Settings of CPU & Power Modules, series 9440 Operating Instructions Operation and Settings of CPU & Power Modules, series 9440 Operation and Settings of CPU & Power Modules, series 9440 R. STAHL SCHALTGERÄTE GMBH Am Bahnhof 30 D-74638 Waldenburg

More information

W1258 LOAD MOMENT INDICATOR OPERATORS MANUAL. Version 1.0 Serial No.: 55M1258COE. United States Canada Great Britain

W1258 LOAD MOMENT INDICATOR OPERATORS MANUAL. Version 1.0 Serial No.: 55M1258COE. United States Canada Great Britain W1258 LOAD MOMENT INDICATOR OPERATORS MANUAL Version 1.0 Serial No.: 55M1258COE United States Canada Great Britain Broken Arrow, OK Ste-Foy, Quebec East Sussex, Hastings Tel: 918-252-1957 Tel: 418-266-6600

More information

SCHMIDT Sensor interface PROFIBUS Instructions for use

SCHMIDT Sensor interface PROFIBUS Instructions for use SCHMIDT Sensor interface PROFIBUS Instructions for use Table of contents 1 Important information... 3 2 Intended use... 4 3 Electrical connection... 4 4 Signalizations... 7 5 Startup... 9 6 Technical data...

More information

Laststufenschalter. Supplement. Betriebsanleitung. Device Profile Document MODBUS

Laststufenschalter. Supplement. Betriebsanleitung. Device Profile Document MODBUS Laststufenschalter Voltage Regulator TAPCON VACUTAP 230 VRAVT I HD Betriebsanleitung Supplement Device Profile Document MODBUS Alle Rechte bei Maschinenfabrik Reinhausen Weitergabe sowie Vervielfältigung

More information

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD

Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD KNX Product documentation Universal dim actuator 1gang RMD Universal dim actuator 2gang RMD Universal dim actuator 4gang RMD Issue: 19.12.2012 Page 1 of 153 KNX Product documentation Contents 1 Product

More information

LS4600 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Speaker Line Surveillance

LS4600 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Speaker Line Surveillance INSTRUCTION MANUAL LS4600 Speaker Line Surveillance Thank you for choosing another quality product from Amperes Electronics. LS4600 was produced out of extensive research and development effort in which

More information

Interfaces for Local Override Operation

Interfaces for Local Override Operation Interfaces for Local Override Operation Keywords K1644 K2614 K2652 K4602 Local override device (LOD) operating level local override local indication Local indication device (LID) analog output relay module

More information

C-Bus Network Analyser Operating Instructions 5100NA

C-Bus Network Analyser Operating Instructions 5100NA C-Bus Network Analyser Operating Instructions 5100NA 16405.p65 1 16405.p65 2 2 Contents Section Product 1 Contents of package 2 Description 3 Capabilities 4 Connection to the C-Bus network 5 Unit operation

More information

User Guide DMX TESTER

User Guide DMX TESTER User Guide DMX TESTER Document Release Aug. 2006 Revision A Warranty Leviton Manufacturing Co Inc. warrants this control console to be free of material and workmanship defects for a period of two years

More information

PHASED OUT PRODUCT DC2. Microcontroller DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: June 1995

PHASED OUT PRODUCT DC2. Microcontroller DESCRIPTION FEATURES ORDERING INFORMATION. BLN Issued: June 1995 DESCRIPTION DC2 Microcontroller Danfoss DC2 Microcontroller is a multi-loop controller that is environmentally hardened for mobile off-highway control system applications. The DC2 Microcontroller has the

More information

Ellard Product Instructions

Ellard Product Instructions Ellard Product Instructions Motor Controller - V3D Maxi Stock Code Description Roundthorne Ind Est Floats Road Wythenshawe Manchester M23 9WB Tel: +44 (0) 161 945 4561 Fax: +44 (0) 161 945 4566 Iss: 1

More information

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.:

VISY-Output 8. Technical Documentation. 8-Channel relay output module. Version: 3 Edition: Art. no.: Technical Documentation VISY-Output 8 8-Channel relay output module Version: 3 Edition: 2016-09 Art. no.: 350072 FAFNIR GmbH Schnackenburgallee 149 c 22525 Hamburg Germany Tel.: +49 / 40 / 39 82 07 0 Fax:

More information

MiCOM Px3x Series. Self Monitoring. Supplementary Functional Description

MiCOM Px3x Series. Self Monitoring. Supplementary Functional Description MiCOM Px3x Series Self Monitoring Supplementary Functional Description Issue: 02b Release: 11 / 2011 [Self-Monitoring] MiCOM Px3x Series 2 The following document is intended to clarify the Px3x self-monitoring

More information

FWD-40LX2F FWD-40LX2X FWD-32LX2F FWD-32LX2X KLH-W32 KLH-W26

FWD-40LX2F FWD-40LX2X FWD-32LX2F FWD-32LX2X KLH-W32 KLH-W26 FLAT WIDE DISPLAY MONITOR FWD-40LX2F FWD-40LX2X FWD-32LX2F FWD-32LX2X KLH-W32 KLH-W26 PROTOCOL MANUAL 1st Edition Table of Contents 1. Communication Parameters... 1 2. Pin Assignment... 1 3. Communication

More information

AC SMARTMOTION CONTROLLERs

AC SMARTMOTION CONTROLLERs AC SMARTMOTION CONTROLLERs for and Generic Slave FAULT LIST and TROUBLESHOOTING (Rev. 2.4: March 2016) SME S.p.A. Via della Tecnica, n 40 36071 Arzignano (VI) - ITALY Phone:+39 (0444) 470511 Fax: +39 (0444)

More information

MDC-GSM. GSM module for C.M.I. Operating manual. Version 2.03 EN

MDC-GSM. GSM module for C.M.I. Operating manual. Version 2.03 EN MDC-GSM Version 2.03 EN GSM module for C.M.I. Operating manual en Table of Contents Description... 4 Commissioning... 4 Power supply... 6 Rules for text input... 6 Settings... 7 Contacts... 7 SMS inputs...

More information

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design)

Product Information. DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) Product Information DCM Standard indoor stations TK IS A 514 A.. TK IS A 514 AD.. (Design) ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Phone +49.2355.806-0 Fax +49.2355.806-189 E-Mail:

More information

SCHOTT EasyLED Series

SCHOTT EasyLED Series SCHOTT EasyLED Series LED illumination system for stereomicroscopy OPERATING INSTRUCTIONS Autorisierter Fachhandelspartner: Pulch + Lorenz GmbH Am Untergr n 23 D - 79232 March - Buchheim Tel: 07665 9272-0

More information

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM

FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM FACTORY AUTOMATION MANUAL PMI360D-F130-IE8-V15 INDUCTIVE POSITIONING SYSTEM With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

ZWS12n AUS chain actuator user manual (Motor Class C)

ZWS12n AUS chain actuator user manual (Motor Class C) GB ZWS12n AUS chain actuator user manual (Motor Class C) Contents Safety rules...2 Description...3 Interoperability of devices different manufacturers...4 Including ZWS12n actuator into Z-Wave network...4

More information

V-9908 MESSAGE/PAGE PANEL

V-9908 MESSAGE/PAGE PANEL Issue 4 V-9908 MESSAGE/PAGE PANEL Introduction These instructions contain the specifications and guidelines necessary to install, operate, and maintain the V-9908, /Page Panel. The V-9908 /Page Panel provides

More information

Control system MultiDrive 2 with D3 joysticks

Control system MultiDrive 2 with D3 joysticks means total control Control system MultiDrive 2 with D3 joysticks Technical description Control system MultiDrive 2 with D3 joysticks D3 joysticks and Display... Driver display With their comfortable pistol

More information

AP70 MK2 Operator Manual

AP70 MK2 Operator Manual AP70 MK2 Operator Manual ENGLISH navico-commercial.com Preface Disclaimer As Navico is continuously improving this product, we retain the right to make changes to the product at any time which may not

More information

Functional safety manual RB223

Functional safety manual RB223 SD00011R/09/EN/13.13 71238251 Products Solutions Services Functional safety manual RB223 Passive barrier Application Galvanic isolation of active 0/4 to 20 ma signals from transmitters, valves and adjusters,

More information

Obsolete. BR Series USB Tech Kit. B l u e R i d g e. T e c h n o l o g i e s. User Guide. Page 1. Hardware and Software Instructions

Obsolete. BR Series USB Tech Kit. B l u e R i d g e. T e c h n o l o g i e s. User Guide. Page 1. Hardware and Software Instructions Hardware and Software Instructions Page 1 Attention Page 2 This section serves as a notice of the immediate or potential dangers involved when working with the equipment described throughout this manual.

More information

Manual. Simrad IS70/IS80 Rudder Indicators RI70 and RI80. English

Manual. Simrad IS70/IS80 Rudder Indicators RI70 and RI80. English Manual Simrad IS70/IS80 Rudder Indicators RI70 and RI80 English www.simrad-yachting.com A brand by Navico - Leader in Marine Electronics Manual Simrad IS70/IS80 Rudder indicators RI70 and RI80 English

More information

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please

More information

Chapter 2: Installation. ST80 Multiview. Operation & Setup

Chapter 2: Installation. ST80 Multiview. Operation & Setup Distributed by Any reference to Raytheon or RTN in this manual should be interpreted as Raymarine. The names Raytheon and RTN are owned by the Raytheon Company. Chapter 2: Installation 1 ST80 Multiview

More information

PROCESS AUTOMATION MANUAL. Universal Transmitter Power Supply. KF**-CRG2-(Ex)1.D ISO9001

PROCESS AUTOMATION MANUAL. Universal Transmitter Power Supply. KF**-CRG2-(Ex)1.D ISO9001 PROCESS AUTOMATION MANUAL Universal Transmitter Power Supply KF**-CRG2-(Ex)1.D ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The General Terms

More information

PAC BI-DP BIM and 8701-CA-BI Carrier

PAC BI-DP BIM and 8701-CA-BI Carrier June 2013 PAC8000 8507-BI-DP BIM and 8701-CA-BI Carrier PROFIBUS DP Bus Interface Module and Carrier The 8507-BI-DP Bus Interface Module (BIM) provides the communications link between the PAC8000 series

More information

Communication FU UHF

Communication FU UHF OBID i-scan MANUAL Communication FU UHF Communication Function Unit UHF Function Unit Commands Reader FU (Function Unit) final public (B) 2008-05-30 H80302-0e-ID-B.doc Copyright 2008 by FEIG ELECTRONIC

More information

BA684DF-P PROFIBUS PA Field mounting Fieldbus Display

BA684DF-P PROFIBUS PA Field mounting Fieldbus Display BA684DF-P PROFIBUS PA Field mounting Fieldbus Display Issue: 3 Issue: 3 8 th December 2011 2 CONTENTS 1. Description 1.1 Documentation 1.2 Version 3.0 firmware 2. Operation 2.1 Controls 3. System Design

More information

Operating Instructions. DALI-Gateway

Operating Instructions. DALI-Gateway Operating Instructions 1. Safety instructions Electrical equipment must be installed and fitted by qualified electricians only. Failure to observe the instructions may cause damage to the device and result

More information

I/O module (Expansion module)

I/O module (Expansion module) I/O module (Expansion module) Variomat Variomat Giga Reflexomat Servitec V2.00 02.02.2015 GB Operating manual Original operating manual English I/O module (Expansion module) Contents 02.02.2015 Contents

More information

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3

Polymer Electric. Operating Instructions. Control Unit SG-EFS 1X4 ZK2/1 8k2. Version 3 Operating Instructions Control Unit SG-EFS 1X4 ZK2/1 8k2 Version 3 1003100 SG-EFS 104 ZK2/1 8k2 24 V=/~ 7500354 SG-EFS 134 ZK2/1 8k2 230 V~ Original instructions GmbH & Co. KG Polymer Electric Örlinger

More information

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual.

RGBW Mini Moving Head Stage Spot Light Model: SSL1. User Manual. RGBW Mini Moving Head Stage Spot Light Model: SSL1 User Manual www.talentaudio.com Thank you for purchasing the Talent RGBW Mini Moving Head Lighting Fixture. Please read this user guide for safety and

More information

Intrinsically safe batch controller Batching Master 110i

Intrinsically safe batch controller Batching Master 110i Intrinsically safe batch controller Batching Master 110i Installation Guide BVS 04 AT E 172 Revision 12.2 IBS BatchControl GmbH Im Sträßchen 2-4 Tel.: ++49 2441 9199 801 53925 Kall Fax.: ++49 2441 9199

More information

Simrad Marine Electronics. Setup and Commissioning Instructions for Boatbuilders and Dealers

Simrad Marine Electronics. Setup and Commissioning Instructions for Boatbuilders and Dealers Simrad Marine Electronics Setup and Commissioning Instructions for Boatbuilders 18_8_2010 1. Introduction and Contents The purpose of this document is to set out, in clear and simple instructions, the

More information

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A)

Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M A) Meter Centraliser Alarm Centraliser Unit LM50-TCP (Code M31521) INSTRUCTION MANUAL (M9813380120-A) 1.- BASIC INSTRUCTIONS 1.1.- Checks on receipt. This manual assists in the installation and handling of

More information

T4HD: Installation Supplement R8.1.13

T4HD: Installation Supplement R8.1.13 THD: Installation Supplement R8.. Smartscan Incorporated 08 Eight Mile Road Livonia MI 8 Tel: (8)77-900 Fax: (8) 77-7 Web: www.smartscaninc.com Smartscan Incorporated Livonia, Michigan THD The use of this

More information

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer

Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer USER'S MANUAL Panorama rudder indicator TRI-2 Analogue or CAN input Approved according to MED Three extra large scales Long-life LED illumination Built-in dimmer DEIF A/S Frisenborgvej 33 DK-7800 Skive

More information

Supplementary device manual AS-i controller e with Profibus DPV1 A AC1355, AC1356 AC1365, AC1366

Supplementary device manual AS-i controller e with Profibus DPV1 A AC1355, AC1356 AC1365, AC1366 Supplementary device manual AS-i controller e with Profibus DPV1 A AC1355, AC1356 AC1365, AC1366 AS-i master profile: M4 Firmware: from version RTS 3.0 onwards Target: from V.15 onwards for CoDeSys from

More information

Zeus 2 QuickStart Guide

Zeus 2 QuickStart Guide Zeus QuickStart Guide Font panel 7 units 9 & units 5 6 4 9 7 4 MARK 5 6 7 7 MARK 8 No. Description Touch screen Rotary knob. Rotate to scroll through menu items, then press to confirm a selection. Rotate

More information

1. Overview of YC-Link/E Overview Part names of YC-Link/E compatible units Installation and settings 3

1. Overview of YC-Link/E Overview Part names of YC-Link/E compatible units Installation and settings 3 CONTENTS YC-Link/E User s Manual 1. Overview of YC-Link/E 1 1.1 Overview 1 1.2 Part names of YC-Link/E compatible units 2 2. Installation and settings 3 2.1 Connecting the LAN cables 3 2.2 LAN cable type

More information

FACTORY AUTOMATION MANUAL IC-KP-B6-V15B IC-KP-B6-2V15B IC-KP-B6-SUBD

FACTORY AUTOMATION MANUAL IC-KP-B6-V15B IC-KP-B6-2V15B IC-KP-B6-SUBD FACTORY AUTOMATION MANUAL IC-KP-B6-V15B IC-KP-B6-2V15B IC-KP-B6-SUBD Communication in "IRI-B6" and "IVI-B6 mode With regard to the supply of products, the current issue of the following document is applicable:

More information

Decoders Wilfrid Laurier University

Decoders Wilfrid Laurier University Decoders Wilfrid Laurier University Wilfrid Laurier University January 27, 2012 A decoder usually converts one type of input pattern into a corresponding output pattern. A decoder usually converts one

More information

C10 Color Display Configuration Manual

C10 Color Display Configuration Manual C10 Color Display Configuration Manual P/N 99954-620161 All information, illustrations, photographs and specifications contained in this book are based on the latest product information available at the

More information

Electrical devices may only be mounted and connected by electrically skilled persons.

Electrical devices may only be mounted and connected by electrically skilled persons. DALI gateway TW Art. No. : 2099REGHE Operating instructions 1 Safety instructions Electrical devices may only be mounted and connected by electrically skilled persons. Serious injuries, fire or property

More information

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface

Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC. S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Preface Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) SIMATIC S7-1500/ET 200MP Power supply module PS 25W 24VDC (6ES7505-0KA00-0AB0) Manual Preface Documentation guide 1 Product overview 2 Wiring 3 Parameters

More information

EL731 PROFIBUS INTERFACE

EL731 PROFIBUS INTERFACE Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/el731 EL731 PROFIBUS INTERFACE Revision 0-A-032816 Copyright 2016 Littelfuse Startco All rights reserved. Document Number: PM-1011-EN

More information

GO XSE Quick Guide. Front panel. The System controls dialog. No. Key Function

GO XSE Quick Guide. Front panel. The System controls dialog. No. Key Function GO XSE Quick Guide EN Front panel 1 No. Key Function 1 Power Press and hold to turn the unit ON/OFF. Press once to display the System control dialog. The System controls dialog Used for quick access to

More information

SK-1011-SQ Digital Access Keypad with 5A Relay Output

SK-1011-SQ Digital Access Keypad with 5A Relay Output User Operation for the SK--SQ. Using the User Codes: A. User codes operate the door (4-8 digits long). Press u u u u B. The key must also be pressed if the keypad is in manual-entry mode. Press u u u u

More information