1 VCE Vblock Specialized Systems for Extreme Applications Gen 2.1 Physical Planning Guide Version 1.3 May 2015

2 Revision History Date Vblock System Document revision Description of changes May 2015 Gen Added environmental information for the EMC VNXe 3150 and EMC VNXe 3300 Combined power, heat, and physical specifications in a single table December 2014 Gen Added EMC XtremIO support shelf information Updated cabinet elevations April 2014 Gen Terminology changes and updates to cabinet elevations February 2014 Gen Initial release Revision History 2

3 Contents Introduction...4 Accessing VCE documentation...5 Cabinet and power specifications...6 Cabinet specifications... 6 Cabinet floor cutouts... 7 POU specifications... 9 Europe... 9 Japan North America...12 Component and environmental specifications...13 Cisco and EMC component specifications...13 Environmental requirements...15 Sample configurations Cabinet specifications for sample configurations Sample single cabinet configuration...17 Sample dual cabinet configuration Reference materials Contents

4 Introduction This document provides the information required for planning the installation of a Vblock Specialized Systems for Extreme Applications at a customer site. The target audience for this document includes VCE field personnel and partners who assist customers in planning their data center requirements. Use this document in conjunction with the VCE Vblock Systems Site Survey. The data provided in this document is for reference only. For the most current product specifications, refer to the manufacturer s documentation. The VCE Glossary defines terms and acronyms that are related to Vblock Systems. To suggest documentation changes and provide feedback on this guide, send an to docfeedback@vce.com. Include the name of this guide, the topic name where your comment applies, and your feedback. Introduction 4

5 Accessing VCE documentation Select the documentation resource that applies to your role. Role Customer VCE Partner Cisco, EMC, VCE, or VMware employee VCE employee Resource support.vce.com A valid username and password are required. Click VCE Download Center to access the technical documentation. partner.vce.com A valid username and password are required. portal.vce.com sales.vce.com/saleslibrary or vblockproductdocs.ent.vce.com 5 Accessing VCE documentation

6 Cabinet and power specifications Cabinet specifications Cabinet specifications provide Vblock System cabinet dimensions and weight information. The cabinets come with locking front and back cabinet doors. Keys are shipped attached with cable ties to the front door and can be used for both the front and back doors. Cabinets are shipped with two side panels. The cabinets are designed to be built contiguously and bolted together. Because of this, there is no need for side panels between the cabinets. VCE does not encourage customers to put space between cabinets, because this requires an extended lead time on the order. The cross-cabinet connections would not reach, and custom cables would need to be ordered. The Vblock Specialized Systems for Extreme Applications uses Panduit NetSERV cabinets. The customized cabinet displays the VCE logo, provides a customized cable management system, and includes casters. Panduit performs extensive testing to ensure the casters can support the cabinet weight and up to 2,000 lb (907 kg) of equipment. Seismic brackets are included automatically in the Panduit rack kit. The cabinets are rated at a seismic zone 3 with 1,102 lb (500 kg) of installed equipment inside. In addition, the pallets used to ship VSS XAPP cabinets are specifically engineered to withstand the added weight of components shipped in the cabinet. Base cabinet dimensions The following illustration shows the VSS XAPP base cabinet dimensions. The Vblock System cabinet height including the casters is 6 feet 8 in. (2,026 mm). The illustration shows the height without the casters. Cabinet and power specifications 6

7 Cabinet specifications with no equipment loaded The following cabinet specifications are for an empty VSS XAPP cabinet. Measure Total shipping weight Floor footprint Cabinet weight Air space Packaged dimensions Packaged cabinet height Specification 667 lb (303 kg) based on the following weights: Cabinet = 386 lb (175 kg) Pallet = 137 lb (62.14 kg) Two side panels = 100 lb (43.45 kg) Packaging = 44 lb (19.95 kg) in. (700 mm) wide x in. (1,200 mm) deep (for general sizing, use 28 in. wide x 48 in. deep) 386 lb (175 kg) without side panels 486 lb (220 kg) with side panels in. wide x 50.7 in. deep x in. tall ( x 1, x 2, mm) 42.0 in. wide x 56.0 in. deep x 86.0 in. tall (1,068 x 1,424.4 x mm) in. (2,178 mm) The cabinet weight does not include the 1RU, 20 lb (9.07 kg) support shelf that might be required for an EMC XtremIO controller. All controllers in a cabinet do not require a support shelf. The following table lists the number of shelves that are required for each EMC XtremIO cluster size. Cluster size Shelves per cluster Total additional weight One EMC XtremIO cluster 2 40 lb (18.14 kg) Two EMC XtremIO clusters 3 60 lb (27.22 kg) Cabinet floor cutouts Cabinet floor cutouts provide floor specifications required prior to the installation of a Vblock System. The floor cutout shows how the cabinet doors open, how much clearance is required for the front and back doors, and where the cable drop holes should be located in the floor tile. This is a standard configuration floor layout, 28 in. (700 mm) wide x 48 in. (1,200 mm) deep. The floor mounting positions shown are when casters or levelers are used (using anti-tip brackets). Equipment rail spacing is factory set. 7 Cabinet and power specifications

8 Base cabinet floor cutout Cabinet and power specifications 8

9 Network cabinet floor cutout The network cabinet has a finger cable management area in the front of the cabinet as shown: POU specifications These topics provide specifications for the power outlet units (POUs) for different regions. The VCE Vblock System Data Protection Guide provides information about available data protection solutions. Europe This topic provides specifications for the POUs for Europe. Panduit full-height POUs weigh 17 lb (7.7 kg). The half-height POUs weigh 8.8 lb (4 kg). 9 Cabinet and power specifications

10 The largest power cord plug is approximately 4 x 4 in. (2,839 x 2,839 mm). Customer input feed Panduit part number Maximum per cabinet Plug / Receptacle Description Three-phase Wye 32 A 230/ 400 V QZ1D2P6BM30P A, 230/400 V x 3~ Wye 4P/5W IEC 60309, Splash proof 24 receptacles 15 A, IEC 60320/C13 6 receptacles 20 A, 250 V Straight blade IEC 60320/C19 Three-phase Wye 32 A 230/ 400 V QZ1D2P3BN24Z A, 230/400 V x 3~ Wye 4P/5W IEC 60309, Splash proof 12 receptacles 10 A, IEC 60320/C13 12 receptacles 16 A, IEC 60320/C19 Three-phase Wye 16 A 230/ 400 V QZ1D2Q0BA30P A, 230/400 V x 3~ Wye 4P/5W IEC 60309, Splash proof 24 receptacles 10 A, IEC 60320/C13 6 receptacles 16 A, 250 V Straight blade IEC 60320/C19 Single-phase 32 A 230 V (half-height) QN1D2B2BN0861 (master) 2 (master) 4 (slave) 32 A, 250 V, Singlephase, 2P/3W, IEC 60309, Splash proof QD0D2B2BN0861 (slave) 6 receptacles 10 A, 250 V Straight blade IEC 60320/C13 2 receptacles 16 A, 250 V Straight blade IEC 60320/C19 Japan This topic provides specifications for the POUs for Japan. Cabinet and power specifications 10

11 Panduit full-height POUs weigh 17 lbs (7.7 kg). The half-height POUs weigh 8.8 lbs (4 kg). The largest power cord plug is approximately 4 x 4 in. (2,839 x 2,839 mm). Customer input feed Panduit part number Maximum per cabinet Plug / Receptacle Description Three-phase Delta 30 A 208 V QZ1B1N3BN30P1J 4 30 A, 250V x 3~ Delta Twist lock JIS C8303 L15-30P 24 receptacles 15 A, IEC 60320/C13 6 receptacles 20 A, IEC 60320/C19 Single-phase 30 A 208 V (half-height) QN1B1L2BN0861J (master) QD0B1L2BN0861J (slave) 2 (master) 4 (slave) 30 A, 250 V, Singlephase Twist lock JIS C8303 L6-30P 6 receptacles 15 A, IEC 60320/C13 2 receptacles 20 A, IEC 60320/C19 Three-phase Delta 60 A 208 V QZ1B2G6BN24R1J 2 60 A, 250V x 3~ Delta Twist lock JIS C8303 L15-30P 3P/4W IEC 60309, Splash proof 18 receptacles 15 A, IEC 60320/C13 6 receptacles 20 A, IEC 60320/C19 Single-phase 60 A 208 V QZ1B2C3BN30P1J 4 60 A, 250V, Singlephase 2P/3W IEC 60309, Splash proof 24 receptacles 15 A, IEC 60320/C13 6 receptacles 20 A, IEC 60320/C19 11 Cabinet and power specifications

12 North America This topic provides specifications for the POUs for North America. Panduit full-height POUs weigh 17 lbs (7.7 kg). The half-height POUs weigh 8.8 lbs (4 kg). The largest power cord plug is approximately 4 x 4 in. (2,839 x 2,839 mm). Customer input feed Panduit part number Maximum per cabinet Plug / Receptacle Description Three-phase Delta 30 A 208 V QZ1B1N3BN30P A, 250 V x 3~ Delta Twist lock NEMA L15-30P 24 receptacles 15 A, IEC 60320/C13 6 receptacles 20 A, IEC 60320/C19 Single-phase 30 A 208 V (half-height) QN1B1L2BN0861 (master) QD0B1L2BN0861 (slave) 2 (master) 4 (slave) Single-phase, 30 A, 250V Twist lock NEMA L6-30P 6 receptacles 15 A, IEC 60320/C13 2 receptacles 20 A, IEC 60320/C19 Three-phase Delta 60 A 208 V QZ1B2G6BN24R A, 250 V x 3~ Delta 3P/4W IEC 60309, Splash proof 18 receptacles 15 A, IEC 60320/C13 6 receptacles 20 A, IEC 60320/C19 Three-phase Delta 60 A 208 V QZ1B2G6BN24Z A, 250 V x 3~ Delta 3P/4W IEC 60309, Splash proof 12 receptacles 15 A, IEC 60320/C13 Cabinet and power specifications 12

13 Customer input feed Panduit part number Maximum per cabinet Plug / Receptacle Description 12 receptacles 20 A, IEC 60320/C19 Single-phase 60 A 208 V QZ1B2C3BN30P1 4 Single-phase, 60 A, 250 V 2P/3W IEC 60309, Splash proof 24 receptacles 15 A, IEC 60320/C13 6 receptacles 20 A, IEC 60320/C19 Component and environmental specifications EMC component specifications This topic provides the specifications for EMC components that might be in a VSS XAPP. Model Maximum power (W) Maximum thermal (BTU/hr) Airflow ft³/min (assumes 150 cfm per Kwh) Maximum weight Rack units Depth 1 EMC XtremIO (1- cabinet configuration) 2 EMC XtremIO cluster (2- cabinet configuration) EMC XtremIO Storage Controller (SC) EMC XtremIO Disk Array Enclosure (DAE) EMC XtremIO Battery Backup Unit (BBU) 750 2, lb. (562.5 kg) 1,726 5, lb. (768.9 kg) 300 N/A N/A 40.0 lb. (18.1 kg) 1,130 3, lb. (18.1 kg) N/A N/A N/A 45.0 lb. (20.4 kg) in. (43.8 cm) in. (43.8 cm) in. (70.9 cm) in. (33.0 cm) in. (55.6 cm) 13 Cabinet and power specifications

14 Model Maximum power (W) Maximum thermal (BTU/hr) Airflow ft³/min (assumes 150 cfm per Kwh) Maximum weight Rack units Depth EMC XtremIO Infiniband Switch EMC VNXe 3150 Processor Enclosure (3.5 in. drives) EMC VNXe 3150 Processor Enclosure (2.5 in. drives) EMC VNXe 3150 Expansion Enclosure (3.5 in. drives) EMC VNXe 3300 Processor Enclosure (3.5 in. drives) EMC VNXe 3300 Processor Enclosure (2.5 in. drives) EMC VNXe 3300 Expansion Enclosure (3.5 in. drives) EMC VNXe 3300 Expansion Enclosure (2.5 in. drives) lb. (9.3 kg) lb. (26.4 kg) lb. (21.8 kg) lb. (23.6 kg) 480 1, lb. (43.8 kg) 480 1, lb. (33.3 kg) 480 1, lb. (32.66 kg) 480 1, lb. (17.4 kg) in. (62.7 cm) 2 20 in. (50.8 cm) 2 17 in. (43.18 cm) 2 20 in. (50.8 cm) in. (60.96 cm) in. (54.0 cm) in. (35.56 cm) in. (33.02 cm) Shipping weights To determine the total shipping weight for a particular VSS XAPP, add the packing materials and other components as specified in the cabinet specifications. Cabinet and power specifications 14

15 Environmental requirements The operating temperature, relative humidity, and altitude specifications are shown in the table below. Requirement Operating temperature Relative humidity Operating environment F (10 32 C) at 80% load 20 80% (non-condensing) Altitude ft. ( m) 15 Cabinet and power specifications

16 Sample configurations Cabinet specifications for sample configurations Sample power, thermal, and weight requirements for each cabinet in a sample VSS XAPP with a single and dual-cabinet configuration. This data is for reference only and will vary based on each specific configuration. Shipping weights To determine the total shipping weight for a particular VSS XAPP, add the packing materials and other components as specified in Vblock System cabinet specifications. Sample cabinet specifications: VSS XAPP with a single cabinet configuration The following table provides sample specifications by cabinet. Cabinet Maximum power (W) Maximum thermal (BTU/hr) Weight (lb) Weight (kg) 1 14,146 34,001 1, ,106 27,819 1, ,515 24,260 1, ,515 24,260 1, , Weights include 386 lb (175 kg) for the cabinet and 68 lb (30.8 kg) for the maximum number of full-height POUs per cabinet. Sample cabinet specifications: VSS XAPP with a dual cabinet configuration The following table provides sample specifications by cabinet. Cabinet Maximum power (W) Maximum thermal (BTU/hr) Weight (lb) Weight (kg) 1 13,581 33,762 1, ,306 28,087 1, ,934 22,283 1, Weights include 386 lb (175 kg) for the cabinet and 68 lb (30.8 kg) for the maximum number of full-height POUs per cabinet. Sample configurations 16

17 Sample single cabinet configuration This topic provides elevations for a sample Vblock Specialized Systems for Extreme Applications single cabinet configuration. Cabinet elevations vary based on the specific configuration requirements. These are provided for sample purposes only. For a specific VSS XAPP design, consult your varchitect. VSS XAPP front and rear Sample dual cabinet configuration The topic provides elevations for a sample dual cabinet configuration for the Vblock Specialized Systems for Extreme Applications. Cabinet elevations vary based on the specific configuration requirements. These are provided for sample purposes only. For a specific VSS XAPP design, consult your varchitect. 17 Sample configurations

18 VSS XAPP front and rear Sample configurations 18

19 19 Sample configurations

20 VSS XAPP cabinet 1 Sample configurations 20

21 VSS XAPP cabinet 2 21 Sample configurations

22 VSS XAPP cabinets 1 and 2 front view VSS XAPP cabinets 1 and 2 rear view Sample configurations 22

23 Reference materials Cisco reference materials The calculations in this document are based on information provided by equipment manufacturers. For more information, refer to the manufacturer documentation. Document Cisco Nexus 5000 Series Hardware Installation Guide Cisco Nexus 5548P, 5548UP, 5596UP, and 5596T Switches Data Sheet Cisco Nexus 3000 Series Hardware Installation Guide Cisco Nexus 3064-X, 3064-T, and T Switches Data Sheet Cisco UCS B200 M3 Rack Server Installation and Service Note Cisco UCS 6200 Series Fabric Interconnect Hardware Installation Guide Cisco UCS 6200 Series Fabric Interconnect Data Sheet Cisco UCS 5108 Server Chassis Installation Guide Cisco UCS 5100 Series Chassis Data Sheet Cisco UCS C220 Server Installation and Service Guide Cisco UCS C220 M3 Rack Server Data Sheet Link nexus5000/hw/installation/guide/nexus_5000_hig.html nexus-5000-series-switches/ data_sheet_c html nexus3000/hw/installation/guide/ nexus3000_hardware_install_guide_book.pdf nexus-3000-series-switches/ data_sheet_c html blade-servers/b200m3.html unified_computing/ucs/hw/6200-install-guide/ 6200_HIG.html data_sheet_c html unified_computing/ucs/hw/chassis-install-guide/ ucs5108_install.html data_sheet_c _ps10276_products_data_she et.html C220/install/C220.html %20notes&product_id=31111&resource=DOC_LIB&ct=C MS.CT.0840 EMC reference materials The calculations in this document are based on information provided by equipment manufacturers. For more information, refer to the manufacturer documentation. Document EMC XtremIO Technical Data Sheet Link 23 Reference materials

24 For more information, refer to EMC Online Support at support.emc.com. To calculate power consumption and heat dissipation for a specific storage configuration, refer to the EMC power calculator at powercalculator.emc.com. Panduit reference materials To access the Panduit POU documentation, refer to and search for the part number. For more information, refer to Cabinet and power outlet unit specifications section of this guide and refer to the appropriate section for Europe, Japan, or North America. Reference materials 24

25 The information in this publication is provided "as is." Dell Inc. makes no representations or warranties of any kind with respect to the information in this publication, and specifically disclaims implied warranties of merchantability or fitness for a particular purpose. Use, copying, and distribution of any software described in this publication requires an applicable software license. Copyright Dell Inc. or its subsidiaries. All Rights Reserved. Dell, EMC, and other trademarks are trademarks of Dell Inc. or its subsidiaries. Other trademarks may be the property of their respective owners. Published in the USA in May Dell EMC believes the information in this document is accurate as of its publication date. The information is subject to change without notice. 25 Copyright

Dell EMC. Converged Technology Extension for Isilon Storage Product Guide

Dell EMC. Converged Technology Extension for Isilon Storage Product Guide Dell EMC Converged Technology Extension for Isilon Storage Product Guide Document revision 1.7 December 2017 Revision history Date Document revision Description of changes December 2017 1.7 Added Generation

More information

VCE Vblock System 100. Gen 2.3 Architecture Overview

VCE Vblock System 100. Gen 2.3 Architecture Overview VCE Vblock System 100 Gen 2.3 Architecture Overview Document revision 2.6 November 2014 Revision history Date Vblock System Document revision Description of changes November 2014 Gen 2.3 2.6 Added the

More information

ECS APPLIANCES. Specification Sheet

ECS APPLIANCES. Specification Sheet Specification Sheet ECS APPLIANCES This 3rd Generation object storage solution from Dell EMC, ECS is built for accelerating digital transformation by bridging both traditional and next generation applications.

More information

DELL EMC VPLEX FAMILY

DELL EMC VPLEX FAMILY Specification Sheet DELL EMC VPLEX FAMILY Introduction Dell EMC VPLEX enables IT organizations to create a storage architecture that enables a data center to be: Always available even in the face of disasters

More information

E-Series Site Preparation Guide

E-Series Site Preparation Guide E-Series Site Preparation Guide September 2017 215-11797_A0 doccomments@netapp.com Table of Contents 3 Contents Deciding whether to use this guide... 10 Specifications of the model 3040 40U cabinet...

More information

StorNext M440 Site Planning Guide

StorNext M440 Site Planning Guide StorNext M440 Contents StorNext M440 Site Planning Guide Included with Your StorNext M440... 1 Professional Installation Requirements. 2 Site Requirements... 2 Shipping Information... 3 StorNext M440 System

More information

EMC Symmetrix VMAX Cloud Edition

EMC Symmetrix VMAX Cloud Edition EMC Symmetrix VMAX Cloud Edition VERSION 2.2 Automation Appliance Physical Planning Guide REV 02 Copyright 2013-2013 EMC Corporation. All rights reserved. Published in the USA. Published December, 2013

More information

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001

Dell Storage Center. Getting Started Guide. SCv2000 and SCv2020 Storage System. Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Dell Storage Center SCv2000 and SCv2020 Storage System Getting Started Guide Regulatory Model: E09J, E10J Regulatory Type: E09J001, E10J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important

More information

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide Dell SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

EMC SYMMETRIX VMAX 10K

EMC SYMMETRIX VMAX 10K EMC SYMMETRIX VMAX 10K EMC Symmetrix VMAX 10K with the Enginuity operating environment delivers a multi-controller, scale-out architecture with consolidation and efficiency for the enterprise. The VMAX

More information

Vertiv VR Rack 1.0 GENERAL

Vertiv VR Rack 1.0 GENERAL 1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic

More information

Technical Specifications

Technical Specifications Technical s This appendix lists the technical specifications for the Cisco UCS 5108 server chassis and includes the following sections: KVM Cable, page 1 Chassis s, page 2 Environmental s, page 3 s for

More information

Dell SC460 Expansion Enclosure Getting Started Guide

Dell SC460 Expansion Enclosure Getting Started Guide Dell SC460 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:

More information

ELASTIC CLOUD STORAGE (ECS) APPLIANCE

ELASTIC CLOUD STORAGE (ECS) APPLIANCE Specification Sheet ELASTIC CLOUD STORAGE (ECS) APPLIANCE Dell EMC Elastic Cloud Storage (ECS ) Appliance is a multi-purpose, software-defined cloud-storage platform. This 3rd Generation object-based solution

More information

POWERMAX FAMILY. Appliance-based packaging. PowerMax 2000 and Specifications. Specification Sheet. PowerMax Arrays

POWERMAX FAMILY. Appliance-based packaging. PowerMax 2000 and Specifications. Specification Sheet. PowerMax Arrays Specification Sheet POWERMAX FAMILY PowerMax Arrays PowerMax 2000 and 8000 The new family of Dell EMC NVMe (Non-Volatile Memory Express) arrays resets the bar for enterprise storage with new levels of

More information

Dell EMC. VxBlock Systems for VMware NSX 6.3 Architecture Overview

Dell EMC. VxBlock Systems for VMware NSX 6.3 Architecture Overview Dell EMC VxBlock Systems for VMware NSX 6.3 Architecture Overview Document revision 1.1 March 2018 Revision history Date Document revision Description of changes March 2018 1.1 Updated the graphic in Logical

More information

SMART Mobile Stand for interactive displays

SMART Mobile Stand for interactive displays Specifications SMART Mobile Stand for interactive displays Physical specifications Size Mobile stand only Interactive display, interactive overlay or interactive display frame 46 1/2" W 63" H 33 5/8" D

More information

Isilon. Site Preparation and Planning Guide

Isilon. Site Preparation and Planning Guide Isilon Site Preparation and Planning Guide Copyright 2015-2017 Dell Inc. or its subsidiaries. All rights reserved. Published September 2017 Dell believes the information in this publication is accurate

More information

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications

APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications The Cisco Unified Computing System is a next-generation data center platform that unites compute, network,

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Models. Specifications

Models. Specifications CAN YOUR PDU PIVOT? TRUE INNOVATION. ONLY FROM SERVER TECH. You ve never seen anything like this before. Intro- TM ducing the PDU Power Pivot, the newest patented innovation from Server Tech, inventors

More information

Dell EMC. Converged Technology Extensions for Storage Product Guide

Dell EMC. Converged Technology Extensions for Storage Product Guide Dell EMC Converged Technology Extensions for Storage Product Guide Document revision 1.9 December 2017 Revision history Date Document revision Description of changes December 2017 1.9 Removed the topic,

More information

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks

Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks Data Sheet FUJITSU PRIMECENTER M2 19-inch Racks 19-inch Industry Standard Rack Systems The trend to consolidation as a result of virtualization and optimization

More information

System Specifications

System Specifications Environmental s, on page 1 Switch Dimensions, on page 1 Weights for the Chassis, Modules, Fan Trays, and Power Supplies, on page 2 Power s, on page 4 Environmental s Environment Temperature Relative humidity

More information

System Specifications

System Specifications Environmental s, on page 1 Switch Dimensions, on page 1 Weights for the Chassis, Modules, Fan Trays, and Power Supplies, on page 2 Power s, on page 3 Environmental s Environment Temperature Relative humidity

More information

DELL EMC VMAX3 FAMILY

DELL EMC VMAX3 FAMILY DELL EMC VMAX3 FAMILY VMAX 100K, 200K, 400K The Dell EMC VMAX3 TM family delivers the latest in Tier-1 scale-out multi-controller architecture with unmatched consolidation and efficiency for the enterprise.

More information

Netfinity White Paper Netfinity Technology Center

Netfinity White Paper Netfinity Technology Center Netfinity White Paper Netfinity Technology Center Rack Storage Expansion Enclosure Planning Guide Abstract This paper is designed for use by Pre-Sales technical marketing representatives. This includes

More information

APC APPLICATION NOTE #74

APC APPLICATION NOTE #74 #74 Configuration of InfraStruXure for Data Centers to Support Dell PowerEdge 1855 Abstract Many companies are making plans to incorporate Dell PowerEdge Blade Servers into their data center applications.

More information

Lenovo 42U 1200mm Deep Racks Product Guide

Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200 mm Deep Static and Dynamic Rack offerings are industry-standard 19-inch server cabinets that are designed for high availability server environments.

More information

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS Dell EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery with high-speed, inline deduplication.

More information

DELL EMC SC SERIES EXPANSION ENCLOSURES

DELL EMC SC SERIES EXPANSION ENCLOSURES SC All-Flash DELL EMC SC SERIES EXPANSION S Versatile, high-performance storage SCALE ON DEMAND Dell EMC SC Series expansion enclosures help you store more data and reduce overall TCO by seamlessly increasing

More information

Dell SC7020 Storage Controller Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

VCE Vblock and VxBlock Systems 540 Gen 2.1 Architecture Overview

VCE Vblock and VxBlock Systems 540 Gen 2.1 Architecture Overview www.vce.com VCE Vblock and VxBlock Systems 540 Gen 2.1 Architecture Overview Document revision 1.6 February 2016 VCE Vblock and VxBlock Systems 540 Gen 2.1 Architecture Overview Revision history Revision

More information

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS Data Domain Systems Table 1. DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS Dell EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery

More information

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS SPEC SHEET DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS Data Domain Systems Dell EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery

More information

TESLA 1U GPU COMPUTING SYSTEMS

TESLA 1U GPU COMPUTING SYSTEMS TESLA 1U GPU COMPUTING SYSTEMS SP-04975-001_v02 March 2010 Specification DOCUMENT CHANGE HISTORY SP-04975-001_v02 Version Date Authors Description of Change 01 November 13, 2009 GG, SM Preliminary Information

More information

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS

DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS SPEC SHEET DELL EMC DATA DOMAIN DEDUPLICATION STORAGE SYSTEMS Data Domain Systems Dell EMC Data Domain deduplication storage systems continue to revolutionize disk backup, archiving, and disaster recovery

More information

SYSTIMAX Rack and Cabinet Solution

SYSTIMAX Rack and Cabinet Solution SYSTIMAX Rack and Cabinet Solution The SYSTIMAX Rack and Cabinet Solution offer is designed for use in telecommunications equipment installations, providing our SYSTIMAX BusinessPartners and customers

More information

Installing the Cisco MDS 9020 Fabric Switch

Installing the Cisco MDS 9020 Fabric Switch CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet

More information

The Most Advanced Racking Solutions Available!

The Most Advanced Racking Solutions Available! The Most Advanced Racking Solutions Available! 1-877-427-5722 www.sharkrack.com info@sharkrack.com Your local authorized SharkRack reseller: Copyright SharkRack, Inc. Prices and specifications are subject

More information

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview

QuickSpecs. HP Remote Monitoring Power Distribution Units. Overview QuickSpecs Overview (PDU) provide rack level power monitoring over the network. With billing grade accuracy these PDUs are excellent choices for data centers wanting to make the most of circuit capacity

More information

System Specifications

System Specifications Environmental Specifications, page 1 Switch Dimensions, page 1 Weights and Quantities for the Chassis, Modules, Fan Trays, and Power Supplies, page 2 Power Specifications, page 4 Environmental Specifications

More information

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide

IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide IBM 1U Switched and Monitored Power Distribution Units IBM System x at-a-glance guide The IBM 1U Switched and Monitored Power Distribution Units (PDUs) make it quick and simple to deploy, protect, and

More information

Artico NAS Storage Appliance Site Planning Guide

Artico NAS Storage Appliance Site Planning Guide Artico NAS Storage Appliance Contents Artico NAS Storage Appliance Site Planning Guide Site Requirements... 2 Shipping Information... 2 System Components... 3 Specifications... 8 Selecting an Installation

More information

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R

Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R Metered Rack PDU Rack PDU, Metered, Zero U, 20A, 120V, (24) NEMA 5-20R APC Metered Rack PDU, Input: 120V, Input Connections: NEMA L5-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 120V, Output Connections:

More information

Cisco Nexus 7000 Series.

Cisco Nexus 7000 Series. Data Sheet Cisco Nexus 7000 Series Chassis Product Overview The Cisco Nexus 7000 Series Switches combine the highest levels of scalability with operational flexibility. The Cisco Nexus 7000 Series Switches

More information

Server Rack Cabinet Compatibility Guide

Server Rack Cabinet Compatibility Guide Server Rack Cabinet Compatibility Guide Revision 2.4 September 2005 A Guide to the Selection and Evaluation of Server Rack Cabinets for Compatibility and Use with Intel Server Chassis Disclaimer THE INFORMATION

More information

Cisco Nexus 7000 Series

Cisco Nexus 7000 Series Data Sheet Cisco Nexus 7000 Series Switches Product Overview The Cisco Nexus 7000 Series Switches combine the highest levels of scalability with operational flexibility. The Cisco Nexus 7000 Series Switches

More information

VERTIV VR RACK. Selection Guide

VERTIV VR RACK. Selection Guide VERTIV VR RACK Selection Guide VERTIV VR RACK Rapid Deployments Everywhere You Operate Standardize your deployments around the world and bring them online faster with the Vertiv VR rack. The Vertiv VR

More information

<Insert Picture Here> Exadata Hardware Configurations and Environmental Information

<Insert Picture Here> Exadata Hardware Configurations and Environmental Information Exadata Hardware Configurations and Environmental Information Revised July 1, 2011 Agenda Exadata Hardware Overview Environmental Information Power InfiniBand Network Ethernet Network

More information

SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays

SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays SMARTPLAY7 Increase your Deal Size and Profitability with SmartPlays - Comstor and Panduit have joined forces to promote the power and flexibility of UCS combined with market leading energy efficient enclosures.

More information

POWER DISTRIBUTION UNITS (PDUs)

POWER DISTRIBUTION UNITS (PDUs) P R O D U C T D ATA S H E E T POWER DISTRIBUTION UNITS (s) for CPI Rack and Cabinet Systems K E Y F E AT U R E S Distribute power to multiple devices from a single power connection NEMA, California Style

More information

Over 70% of servers within a data center are not connected to Fibre Channel SANs for any of the following reasons:

Over 70% of servers within a data center are not connected to Fibre Channel SANs for any of the following reasons: Overview The provides modular multi-protocol SAN designs with increased scalability, stability and ROI on storage infrastructure. Over 70% of servers within a data center are not connected to Fibre Channel

More information

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007

Sun StorageTek. 1U Rackmount Media Tray Reference Guide. Sun Doc Part Number: Second edition: December 2007 Sun StorageTek nl 1U Rackmount Media Tray Reference Guide Sun Doc Part Number: 875 4297 10 Second edition: December 2007 Legal and notice information Copyright 2007 Hewlett Packard Development Company,

More information

QuickSpecs. HPE Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview

QuickSpecs. HPE Modular Power Distribution Units (Zero-U/1U Modular PDUs) Overview HPE Modular Power Distribution Units (Zero-U/1U Modular s) Overview HPE Modular s have a unique modular architecture designed specifically for data center customers who want to maximize power distribution

More information

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks)

Retired. Full Rack Vertical PDU Model (Ideal for 36U to 47U racks) Overview The HP Monitored PDUs allow administrators and facility personnel to monitor current draw directly at the rack and per PDU. HP Monitored PDUs are available in both 1 phase and 3 phase and in single

More information

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2

Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2. Cisco CRS 3-Phase AC Power Distribution Unit 2 Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide Cisco CRS 3-Phase AC Power Distribution Unit Installation Guide 2 Cisco CRS 3-Phase AC Power Distribution Unit 2 Revised: November 18, 2016,

More information

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions

QuickSpecs. HPE Standard Series G2 Basic Power Distribution Units (PDU) Overview. Basic, reliable power distribution for your HPE IT solutions Overview Basic, reliable power distribution for your HPE IT solutions G2 Basic PDUs are designed to work precisely with HPE Infrastructure and Compute solutions and guarantee a compatible fit for use with

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server Data Sheet FUJITSU Server Scale out Server Data Sheet FUJITSU Server Scale out Server Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing FUJITSU Server PRIMERGY will give you the servers you

More information

HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array hardware configuration guide

HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array hardware configuration guide HP StorageWorks 4x00/6x00/8x00 Enterprise Virtual Array hardware configuration guide Part number: 5697-7338 Fifth edition: February 2008 Legal and notice information Copyright 2005-2008 Hewlett-Packard

More information

Dell EMC Data Domain DD6300, DD6800, and DD9300 Systems

Dell EMC Data Domain DD6300, DD6800, and DD9300 Systems Dell EMC Data Domain DD6300, DD6800, and DD9300 Systems Version 6.1 Hardware Overview and Installation Guide 302-003-008 REV 07 Copyright 2016-2018 Dell Inc. and its subsidiaries. All rights reserved.

More information

Instruction Manual. Rack PDU XP Series. geistglobal.com

Instruction Manual. Rack PDU XP Series. geistglobal.com Instruction Manual Rack PDU XP Series geistglobal.com Table Of Contents 3 Table of Contents Specifications 4 Overview... 4 Environmental... 4 Tem perature... 4 Hum idity... 4 Elevation... 4 Electrical...

More information

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord

Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord Metered Rack PDU Rack PDU, Metered, Zero U, 5.7kW,208V,(36)C13& (6)C19; 10' Cord APC Metered Rack PDU, Input: 208V 3PH, Input Connections: NEMA L21-20P, Cord Length: 10 feet ( 3.05 meters ), Output: 208V,

More information

VEP4600. Setup Guide

VEP4600. Setup Guide VEP4600 Setup Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage to hardware

More information

S4112-ON Series. Setup Guide

S4112-ON Series. Setup Guide S4112-ON Series Setup Guide Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential damage

More information

Installation and Maintenance

Installation and Maintenance CHAPTER 4 Installation and Maintenance Revised: April 19, 2010, Introduction This chapter explains how to install a SCE 1000 platform in a rack or in a general tabletop or workbench installation. Additionally,

More information

Hassle-free equipment installation

Hassle-free equipment installation 22U 36in Knock-Down Server Rack Cabinet with Casters StarTech ID: RK2236BKF This server rack provides 22U of storage space in a sleek secure cabinet for storing EIA-310 compliant 19 rackmount devices such

More information

Power Enclosure Components

Power Enclosure Components Power Enclosure Components HP BladeSystem p-class 1U Power Enclosure Exploded View Figure 1-5 HP BladeSystem p-class 1U power enclosure exploded view Illustrated Parts Catalog 20 HP BladeSystem p-class

More information

HP Integrity NonStop NS-Series Site Preparation Guide

HP Integrity NonStop NS-Series Site Preparation Guide HP Integrity NonStop NS-Series Site Preparation Guide Abstract This manual provides the physical, electrical, and environmental specifications for use by HP professional service personnel for site preparation,

More information

EMC VMAX Best Practices Guide for AC Power Connections

EMC VMAX Best Practices Guide for AC Power Connections EMC VMAX Best Practices Guide for AC Power Connections For: VMAX3 Family and VMAX All Flash REVISI 06 Copyright 2014-2017 Dell Inc. or its subsidiaries. All rights reserved. Published May 2017 Dell believes

More information

Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide

Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide Dell PowerVault MD3400/3420/3800i/3820i/3800f/ 3820f Storage Arrays Getting Started Guide Regulatory Model: E03J and E04J Series Regulatory Type: E03J001 and E04J001 Notes, Cautions, and Warnings NOTE:

More information

Saver Series. Model: SS16. Model: SS30 & SS26. Model: SS36 & SS32. Model: SS16-W

Saver Series. Model: SS16. Model: SS30 & SS26. Model: SS36 & SS32. Model: SS16-W CARTS & STATIONS Saver Series Saver Series allows you to store, secure, charge and deploy up to 36 devices and protective cases up to 1 thick. Compatible with Laptop, Chromebook, Ultrabook, Netbook, ipad

More information

Junos WebApp Secure 5.0 Hardware Guide

Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide Junos WebApp Secure 5.0 Hardware Guide This document contains a specification for the MWS1000 hardware appliance, as well as instructions for installation into a

More information

VIRTUAL EDGE PLATFORM 4600 Next Generation Access

VIRTUAL EDGE PLATFORM 4600 Next Generation Access VEP4600 Spec Sheet VIRTUAL EDGE PLATFORM 4600 Next Generation Access Purpose-built open ucpe platform to host VNFs (Virtual Networking Functions). Ideal access platform for SD-WAN. The VEP4600 is a Dell

More information

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure

Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Data Sheet FUJITSU Server PRIMERGY CX400 S2 Multi-Node Server Enclosure Scale-Out Smart for HPC and Cloud Computing with enhanced

More information

Solutions Guide for Cisco UCS B and C Series Servers

Solutions Guide for Cisco UCS B and C Series Servers Solutions Guide for Cisco UCS B and C Series Servers The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and virtualization into a

More information

EMC SYMMETRIX VMAX 40K SYSTEM

EMC SYMMETRIX VMAX 40K SYSTEM EMC SYMMETRIX VMAX 40K SYSTEM The EMC Symmetrix VMAX 40K storage system delivers unmatched scalability and high availability for the enterprise while providing market-leading functionality to accelerate

More information

Installation Job Aid for VSP 4450GTX-HT- PWR+

Installation Job Aid for VSP 4450GTX-HT- PWR+ Installation Job Aid for VSP 4450GTX-HT- PWR+ Notices Release 6.1.0.0 NN46251-305 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs

More information

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide

IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide IBM UPS5000 HV Uninterruptible Power Supply for IBM System x Product Guide The IBM UPS5000 HV is a 5 KVA rack-mountable uninterruptible power supply (UPS) that utilizes advanced backup power technology

More information

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM

EMC SYMMETRIX VMAX 40K STORAGE SYSTEM EMC SYMMETRIX VMAX 40K STORAGE SYSTEM The EMC Symmetrix VMAX 40K storage system delivers unmatched scalability and high availability for the enterprise while providing market-leading functionality to accelerate

More information

IBM RDX Removable Disk Backup Solution (Withdrawn) Product Guide

IBM RDX Removable Disk Backup Solution (Withdrawn) Product Guide IBM RDX Removable Disk Backup Solution (Withdrawn) Product Guide The new IBM RDX removable disk backup solution is designed to reliably and cost-effectively help protect your business's valuable assets.

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server

Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server Data Sheet FUJITSU Server PRIMERGY CX400 M4 Scale out Server Workload-specific power in a modular form factor FUJITSU Server PRIMERGY will give you the servers you need to power any workload and changing

More information

30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units 30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent

More information

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired

QuickSpecs. HP Performance Optimized Datacenter (POD) 20ce. Overview. Retired Overview The HP Performance-Optimized Data Center (HP POD) is a containerized datacenter equipped with power infrastructure, cooling and IT power distribution. The HP POD can be deployed within weeks instead

More information

20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units

20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units 20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management

More information

30 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring and Environmental Power Outlet Units. specifications. technical information

30 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring and Environmental Power Outlet Units. specifications. technical information SPECIFICATION SHEET specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management of the in-cabinet power usage. This system helps to quickly

More information

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport

Quick Start. This document describes how to install the Juniper Networks PTX5000 Packet Transport PTX5000 Packet Transport Router Quick Start September 2017 Part Number: 530-066788 Revision 01 This document describes how to install the Juniper Networks PTX5000 Packet Transport Router. Contents Quick

More information

EF-Series EuroFrame Gen 2 Cabinet System

EF-Series EuroFrame Gen 2 Cabinet System Protecting your technology investment. EF-Series EuroFrame Gen 2 Cabinet System The new generation of EF-Series EuroFrame Cabinet is a reliable and economical cabinet solution that supports rack-mount

More information

Installing the HP ProLiant DL380p G8 Server for Avaya one-x Speech

Installing the HP ProLiant DL380p G8 Server for Avaya one-x Speech Installing the HP ProLiant DL380p G8 Server for Avaya one-x Speech Release 6.3 Issue 1 March 2014 Contents Chapter 1: Installing the HP DL380p G8 Server... 5 HP ProLiant DL380p G8 Server overview... 5

More information

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview

QuickSpecs. HP Basic Power Distribution Units (bpdu) Overview Overview HP Basic PDUs are designed to provide reliable and cost effective power distribution for your HP and non-hp IT racks. Offering simple 0U and 1U installation options, HP Basic PDUs are available

More information

Site Preparation for ClearCube Installation. Rev. F

Site Preparation for ClearCube Installation. Rev. F Site Preparation for ClearCube Installation Rev. F EXECUTIVE SUMMARY Because of the centralized nature of the ClearCube architecture, installation of the system requires a certain degree of site preparation.

More information

Data Domain DD6300, DD6800, and DD9300 Systems

Data Domain DD6300, DD6800, and DD9300 Systems Data Domain DD6300, DD6800, and DD9300 Systems Version 6.0 Hardware Overview and Installation Guide 302-003-008 REV 01 Copyright 2016 EMC Corporation. All rights reserved. Published in the USA. Published

More information

Cisco Nexus 7700 Switches Data Sheet

Cisco Nexus 7700 Switches Data Sheet Data Sheet Cisco Nexus 7700 Switches Data Sheet Product Overview The Cisco Nexus 7000 Series Switches are the foundation of the Cisco Unified Fabric solution. Designed to meet the requirements of mission-critical

More information

Installation Job Aid for VSP 4850GTS

Installation Job Aid for VSP 4850GTS Installation Job Aid for VSP 4850GTS Notices Release 6.1.0.0 NN46251-308 Issue 02.01 November 2017 Notice paragraphs alert you about issues that require your attention. The following paragraphs describe

More information

Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)

Intelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5) Faster. Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with Local and Intelligent PDU mounted display option for local current or power monitoring, making phase balancing easier

More information

RMG Series Rack Mount Fiber Enclosures

RMG Series Rack Mount Fiber Enclosures The RMG Series rack mount fiber enclosures is as an integral part of the TE Connectivity product portfolio. The RMG Series fiber enclosure provides rugged and durable protection for patching or splicing

More information

VMAX ALL FLASH FAMILY

VMAX ALL FLASH FAMILY VMAX ALL FLASH FAMILY VMAX 250F, The exciting Dell EMC VMAX family of all-flash arrays now includes the newest powerful member, the VMAX. The VMAX delivers unparalleled performance and scalability as a

More information

How to Sell APC s Cisco Approved Solution for Nexus 7018

How to Sell APC s Cisco Approved Solution for Nexus 7018 NetShelter SX Side Airflow Solution for Cisco Nexus 7018 How to Sell APC s Cisco Approved Solution for Nexus 7018 Objectives Explain Sales Strategy for the Side Airflow Solution for Nexus 7018 Explain

More information

IBM Half-High LTO Generation 5 SAS Tape Drive IBM System x at-a-glance guide

IBM Half-High LTO Generation 5 SAS Tape Drive IBM System x at-a-glance guide IBM Half-High LTO Generation 5 SAS Tape Drive IBM System x at-a-glance guide The fifth-generation IBM Linear Tape-Open (LTO) Half-High Ultrium Drive delivers twice the capacity (up to 3.0 TB) with significantly

More information