SMARTPLAY7. Increase your Deal Size and Profitability with SmartPlays
|
|
- Branden Ferdinand Harrington
- 5 years ago
- Views:
Transcription
1 SMARTPLAY7 Increase your Deal Size and Profitability with SmartPlays - Comstor and Panduit have joined forces to promote the power and flexibility of UCS combined with market leading energy efficient enclosures. - Resellers can now select the Smart Play solution appropriate for their customer and attach a suitable, fully pre-configured Panduit cabinet and infrastructure to the purchase. - Pre-configured solutions to complement Cisco solutions C220 and C240, Flexpod Small and Medium sized systems.
2 CISCO BLADE PROMO B200 Series Base Bundles Blade 200 Series Advanced Bundles Blade 420 Series Name B200 Entry B200 Entry Plus B200 Value B200 Value Plus B200 Performance Bundle B420 Value Cisco SKU UCS-SP7-B200-E UCS-SP7-B200-EP UCS-SP7-B200-V UCS-SP7-B200-VP UCS-SP7-B420-V Standard Dynamic PANDUIT SOLUTION POU Connectivity Blanking Panels TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 Blanking Blind FLBSIM-Y Qty 1 FLBSIM-Y Qty 1 FLBSIM-Y Qty 1 Full Pre- Configured Solutions Configuration (ToR patch panel, cable mgrs, bonding, entry boots and cage nuts) [build on site] configuration (ToR patch panel, cable mgrs, bonding, entry boots and cage nuts) [build on site] configuration (ToR patch panel, cable mgrs, bonding, entry boots and cage nuts) [build on site]
3 CISCO C220 RACK PACKS C220 Rack Server With 2 CPU C220 Rack Server With 2 CPU C220 Rack Server With 2 CPU Name C220 2P Entry 1 C220 2P Entry 2 C220 2P Value 1 C220 2P Value 2 C220 2P Perf 1 C220 2P Perf 2 Cisco SKU UCS-SPR-C220-E1 UCS-SPR-C220-E2 1RU / 1RU UCS-SPR-C220-V1 UCS-SPR-C220-V2 1 RU/ 1RU UCS-SPR-C220-P1 UCS-SPR-C220-P2 1RU / 1RU Standard Dynamic PANDUIT SOLUTION POU Connectivity Blanking Panels TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 Blanking Blind FLBSIM-Y Qty 1 FLBSIM-Y Qty 1 FLBSIM-Y Qty 1 Full Pre- Configured Solutions Configuration (ToR patch panel, cable mgrs, bonding, entry boots and cage nuts) [build on site] configuration (ToR patch panel, cable mgrs, bonding, entry boots and cage nuts) [build on site] configuration (ToR patch panel, cable mgrs, bonding, entry boots and cage nuts) [build on site]
4 CISCO C240 RACK PACKS C240 Rack Server With 2 CPU C240 Rack Server With 2 CPU C240 Rack Server With 2 CPU Name C240 2P Entry 1 C240 2P Entry 2 C240 2P Value 1 C240 2P Value 2 C240 2P Performance 1 C240 2P Performance 2 Cisco SKU UCS-SPR-C240-E1 UCS-SPR-C240-E2 1 RU / 2 RU UCS-SPR-C240-V1 UCS-SPR-C240-V2 1 RU / 2 RU UCS-SPR-C240-P1 UCS-SPR-C240-P2 1 RU / 2 RU Standard Dynamic PANDUIT SOLUTION POU Connectivity QZ1D2Q0BA30P1 Qty 2 Blanking Panels TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 Blanking Blind FLBSIM-Y Qty 1 FLBSIM-Y Qty 1 FLBSIM-Y Qty 1 Full Pre- Configured Solutions Configuration (ToR patch panel, cable mgrs, bonding, entry boots and cage nuts) [build on site] Configuration (ToR patch panel, cable mgrs, bonding, entry boots and cage nuts) [build on site] configuration (ToR patch panel, cable mgrs, bonding, entry boots and cage nuts) [build on site]
5 CISCO C-SERIES PROMO BUNDLES Name C-Series Promo Bundles C220 Value Bundle C220 Value Bundle Plus C-Series Promo Bundles C240 Value Bundle C240 Performance Bundle Cisco SKU UCS-SP7-C220-V UCS-SP7-C220-VP UCS-SP7-C240-V UCS-SP7-C240-P Standard Dynamic PANDUIT SOLUTION POU required when more than 2 UCS chassis are full Connectivity required when more than 2 UCS chassis are full Blanking Panels TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 Blanking Blind FLBSIM-Y Qty 1 FLBSIM-Y Qty 1
6 PANDUIT BLADE PROMO PANDUIT C220 RACK PACKS PANDUIT C240 RACK PACKS PANDUIT C-SERIES PROMO BUNDLES PANDUIT EPOD & FPOD BUNDLES CISCO EPOD & FPOD BUNDLES FlexPod Express ( ExpressPod ) - UCS Director optional FlexPod Entry, Small & Medium - UCS Director optional Name FlexPod Express Small FlexPod Express Medium FlexPod Entry (C220) FlexPod Small (B200) FlexPod Medium (B200) Cisco SKU UCSC-EPOD-C220E-S UCSC-EPOD-C220E-M UCSC-FPOD-C220V UCSB-FPOD-B200S UCSB-FPOD-B200M PANDUIT SOLUTION Standard Dynamic POU QZ1D2Q0BA30P1 Qty 2 Vertical Network POU, 16A, 3 Phase, NOTE: Qty 4 required when more than 2 UCS chassis are full Connectivity UTPSP3MY (3M Cat6 white) UTPSP3MBUY (3M Cat6 blue) Shorter sizes available in 0.5m increments QZ1D2Q0BA30P1 Qty 2 Vertical Network POU, 16A, 3 Phase, NOTE: Qty 4 required when more than 2 UCS chassis are full UTPSP3MY (3M Cat6 white) UTPSP3MBUY (3M Cat6 blue) Shorter sizes available in 0.5m increments Connectivity Kits CQFECK (small connectivity kit) CQFEMCK (medium connectivity kit) Vertical Network POU, 32A, 3 Phase, NOTE: Qty 4 required when more than 2 UCS chassis are full PSF1PXA3MWH (3M Blue Passiv SFP+) Shorter sizes available in 0.5m increments Vertical Network POU, 32A, 3 Phase, NOTE: Qty 4 required when more than 2 UCS chassis are full PSF1PXA3MWH (3M Blue Passiv SFP+) Shorter sizes available in 0.5m increments Vertical Network POU, 32A, 3 Phase, NOTE: Qty 4 required when more than 2 UCS chassis are full PSF1PXA3MWH (3M Blue Passiv SFP+) Shorter sizes available in 0.5m increments Blanking Panels TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 TLBP1S-V Qty 5-30 Blanking Blind FLBSIM-Y Qty 1 FLBSIM-Y Qty 1 FLBSIM-Y Qty 1 FLBSIM-Y Qty 1 FLBSIM-Y Qty 1 Solution Bundle (Off-Site Build) CQSFPK679 Bundled Infrastruture for FlexPod (starter) 600x RU cabinet, bundled connectivity, cable mgt and bonding on dynamic shippable pallet [build and ship] CQSFPK679 Bundled Infrastruture for FlexPod (starter) 600x RU cabinet, bundled connectivity, cable mgt and bonding on dynamic shippable pallet [build and ship] CQSFPK679 Bundled Infrastruture for FlexPod (starter) 600x RU cabinet, bundled connectivity, cable mgt and bonding on dynamic shippable pallet [build and ship] On-Site CQFPK679 (non-dynamnic) CQFPK679 (non-dynamnic) CQFPK679 (non-dynamnic)
7 DATACENTER CABINET STANDARD Panduit energy efficient cabinets consist of thermal solutions that are designed to maintain hot/cold air separation to improve cooling efficiency and reduce energy consumption. When combined with a well-designed cooling system, Panduit integrated thermal solution cabinets can help reduce data center energy costs by up to 40 percent. STANDARD CABINET S-Type 600x RU, single hinge perforated front door, rear perforated split doors, (2) side panels, casters, POU brackets, cage nut rails in Black Part No: S6222B - Complete Air Seal Features Reduce Air Leakage Throughout the Structure by as much as 25%. - Vertical Patching removes the need for 2U at the top of rack for Patching allowing all U for IT equipment deployment. Improves Floor Space Utilization by 10%. - Cable management prevents cables blocking air flow or crossing service points which will save time on maintenance tasks. - On a 4 kilo watt cabinet deployment this could save 1000//year on cooling costs. - This can save save floor space costs between 1000 and 2,500/year/cabinet with similar equipment densities. - This can save from /year on repair and maintenance costs depending on how unruly the client lets the cable get.
8 DATACENTER CABINET DYNAMIC Panduit energy efficient cabinets consist of thermal solutions that are designed to maintain hot/cold air separation to improve cooling efficiency and reduce energy consumption. When combined with a welldesigned cooling system, Panduit integrated thermal solution cabinets can help reduce data center energy costs by up to 40 percent. DYNAMIC CABINET S-Type 600x RU, single hinge perforated front door, rear perforated split doors, (2) side panels, casters, POU brackets, cage nut rails in Black Part No: S6222BSPXCCF119 - Allows solution to be built off site saving on site deployment time and delivering fully loaded cabinets on shock pallets. - Complete Air Seal Features Reduce Air Leakage Throughout the Structure by as much as 25%. - Cable management prevents cables blocking air flow or crossing service points which will save time on maintenance tasks. - This saves hours of on site build which is disruption to the data centre and alien staff on the wrong side of security. - On a 4 kilo watt cabinet deployment this could save 1000//year on cooling costs.
9 POWER OUTLET UNITS (POUs) Panduit s Networked Power Outlet Units (POUs) manage and distribute power to multiple devices through a single power connector to improve the scalability of network build outs. POUs Vertical power strip 32 A, 230/400V, WYE, 24 IEC C-13 and 6 IEC C-19 receptacles, red LED current monitor, 16 Amp two pole magnetic breaker on-off switch with integral switch guard and 3 meter power cord with IEC P+N+E pin in sleeve connector. Complies with IEC , EN 55022, EN and CE Marked. Part No: QZ1D2P6BM30P1 - Single source of PDUs and cabinets to reduce specification and design time to speed deployment. - Power monitoring of thermally optimized cabinet solution including partner validated reference architectures. - Part of comprehensive SmartZone TM monitoring solution. - Single source of responsibility gives you ease of mind and less risk. - You cannot manage what you cannot see. Gives you the ability to control costs. - The solution is the smallest building block of an Enterprise wide Power and Energy Monitoring and control system.
10 CONNECTIVITY As virtualization, consolidation, and convergence initiatives continue to grow, so do the demands placed on the physical infrastructure. To meet the needs for faster processing speeds, low power server inter-connect and I/O consolidation deployments, Panduit offers 10Gig SFP+ Direct Attach Passive Copper Cable Assemblies. CONNECTIVITY SFP+Cable Part No: PSF1PXA3MBU, PSF1PXA3MWH - Length options in 0.5m increments. Option for lenghts up to 15 meters. - 5 colours of black, blue, white, red, and green. - Same as using Cisco cables on Nexus 2K and 5K but more cost effective. - Ideal for high performance computer clustering and other latency sensitive applications. - SFP+ Copper Cable Assemblies Compatibility Table. - Provides a low cost short reach interconnect option with no additional power draw. - Less cable mess and no air flow obstruction reducing purchase cost and ongoing OPEX reduction. The optional lenghts ensure that all TOR switch ports can be used in future deployments. - Different colours for different services saves mainenance time and effort. Adds moves and changes are less disruptive, less disconnet mistakes. - Thinnest Cables at the highets performance for the lest cost solution.
11 BLANKING PANELS To mitigate the possibility of overheating of equipment, control energy costs, and guard against possible downtime in today s busy data centers, Panduit has provided solutions for reducing bypass airflow through open spaces in racks and cabinets. BLANKING PANEL Part No: TLBP1S-V - Block open U spaces to stop recirculation of hot air. - Fast; simply snap panels in place. No screwing or bolting of panels. - All plastic solution; no grounding required. - Minimises bypass airflow in standard EIA 19 racks and cabinets while providing an aesthetic appearance. - Keeps cooling costs to minimum (no waste) and it is easy to deploy.
12 BLANKING BLIND To mitigate the possibility of overheating of equipment, control energy costs, and guard against possible downtime in today s busy data centers, Panduit has provided solutions for reducing bypass airflow through open spaces in racks and cabinets. BLANKING BLIND Part No: FLBSIM-Y - Fits like a bathroom blind with superior sealing and engagement features. - No tools/additional hardware required; optional clip to improve sealing capabilities. - Extremely fast for full cabinet deployment. - Utilize the blanking shade when there is a need to blank out the majority of the cabinet or a need to insert/remove equipment sequentially over time. Blanking shades eliminate lost individual blanking panels and also prevents storing individual blanking panels that are currently not in use. - Speed and simplisity of deployment. Preventing cooling cost wastage. - Reduces cabinet ancillery costs while maintaining maximum deployment speed.
13 Panduit pre-configured infrastructures help reduce the risks associated with adoption of new technologies, such as virtualisation, consolidation and automation, by optimising the physical infrastructure to the logical elements of the network. To reduce planning, design, fulfillment and procurement times, each pre-configured physical infrastructure includes all necessary systems integrated within Panduit cabinets under one part number. SmartPlay Bundles Blade 200 Series Base Bundles Blade 200 Series Adv. Bundles Rack C220 Series Rack C240 Series Bundles Flexpod Entry, Small, Medium (on site build) FlexPod Entry, Small, Medium (build and ship) Panduit Pre-Configured Options CQFPK679 CQSFPK679 - Allows solution to be built of site saving on site deployment time and delivered fully loaded cabinets on shock pallets. - Cables pre-terminated, labled and loomed for non abstructive deployment. - Equipment layout is thermal performance and ensures that future upgrades maintain thermal perameters. - This saves hours of on site build which is disruption to the data centre and alien staff on the wrong side of security. - Labeling ensures future maintanance, moves and changes are completed effectively with minimum disruption. - Fast deployment of upgrades at no risk.
APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications
APC by Schneider Electric Solutions for Cisco Unified Computing System (UCS) Blade Applications The Cisco Unified Computing System is a next-generation data center platform that unites compute, network,
More informationVertiv VR Rack 1.0 GENERAL
1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic
More informationDATACOM CABINETS SOLUTION GUIDE
DATACOM CABINETS SOLUTION GUIDE designed to be better. LEGRAND S CABINET OFFERING Legrand cabinets are designed with cable management, airflow management and effortless installation to meet all network
More informationVCE Vblock Specialized Systems for Extreme Applications. Gen 2.1 Physical Planning Guide
VCE Vblock Specialized Systems for Extreme Applications Gen 2.1 Physical Planning Guide Version 1.3 May 2015 Revision History Date Vblock System Document revision Description of changes May 2015 Gen 2.1
More informationHow to Sell APC s Cisco Approved Solution for Nexus 7018
NetShelter SX Side Airflow Solution for Cisco Nexus 7018 How to Sell APC s Cisco Approved Solution for Nexus 7018 Objectives Explain Sales Strategy for the Side Airflow Solution for Nexus 7018 Explain
More informationData Center Enclosures Best Practices. Maximize the Efficiency of the Enclosure within a Data Center
Data Center Enclosures Best Practices Maximize the Efficiency of the Enclosure within a Data Center Things to ask before selecting Enclosures: Primary Use Severs or Patching, or both determines size. RMU
More informationMECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES. One Dell Way Round Rock, Texas
One Dell Way Round Rock, Texas 78682 www.dell.com DELL ENTERPRISE WHITEPAPER MECHANICAL AND THERMAL CONSIDERATIONS FOR RACK DEPLOYMENT OF THE DELL POWEREDGE M-SERIES Dominick Lovicott Enterprise Thermal
More informationSolutions Guide for Cisco UCS B and C Series Servers
Solutions Guide for Cisco UCS B and C Series Servers The Cisco Unified Computing System is a next-generation data center platform that unites compute, network, storage access, and virtualization into a
More informationHYPERFRAME CABINET & ENCLOSURE SOLUTIONS
HYPERFRAME CABINET & ENCLOSURE SOLUTIONS PERFECT BALANCE OF FORM, FIT AND FUNCTION CABINET & ENCLOSURE SOLUTIONS Our philosophy is simple, to provide you with a complete and innovative solution that meets
More informationData Centre Solutions
Data Centre Solutions Lars-Hendrik Thom Regional Technical Support Manager D-A-CH & Benelux D-LHT@panduit.com Mission Statement is a global, world-class company, committed to designing, manufacturing and
More informationQuickSpecs. HPE G2 Enterprise Series Racks. Overview
Overview are designed for high density IT configurations deployed in a diverse set of environments from the data closet to the data center. Following EIA-310 specifications for 19-inch racks, G2 Enterprise
More informationV-Built Custom Preconfigured Solutions
WWW.SIEMON.COM V-Built Custom Preconfigured Solutions 8 One Part Number, One Price Ready to Roll Available with any Siemon cabinet, rack or enclosure, Siemon s V-Built Custom Preconfigured Solutions are
More informationG5 PDU Installation Guide
G5 PDU Installation Guide 1 Contents Before You Begin... 3 Overview... 3 Important Safety Information... 3 Required Tools... 5 Section 1 Introduction... 6 Classification Overview... 6 Features... 7 Form
More informationVERTIV VR RACK. Selection Guide
VERTIV VR RACK Selection Guide VERTIV VR RACK Rapid Deployments Everywhere You Operate Standardize your deployments around the world and bring them online faster with the Vertiv VR rack. The Vertiv VR
More informationWhere s the Heat Coming From. Leland Sparks Global Account Technical Consultant Belden
Where s the Heat Coming From Leland Sparks Global Account Technical Consultant Belden What is the greatest DC challenge you face? Air Flow to Heat Load Relation Server Inlet Fans Chips Outlet LOAD Dell
More informationHPE Performance Optimized Datacenter (POD) Networking Guide
HPE Performance Optimized Datacenter (POD) Networking Guide Abstract This document provides networking guidance for the various HPE PODs. Part Number: 663145-003R November 2015 Edition: 4 Copyright 2011,
More informationNetShelter SX Cable Management. Organize large volumes of cables from networking switches and patch panels
NetShelter SX Cable Management Organize large volumes of cables from networking switches and patch panels Enclosure Cable Management Rear Vertical Zero U Accessory Channels and Cable Management Accessories
More informationQuickSpecs. HPE G2 Enterprise Series Racks. Overview
Overview are designed for high density IT configurations deployed in a diverse set of environments from the data closet to the data center. Following EIA-310 specifications for 19-inch racks, G2 Enterprise
More informationRack Selection Guide for NetShelter SX
Rack Selection Guide for NetShelter SX Choosing the right rack based on application and equipment type Click here to download the new White Paper #201: How to Choose an IT Rack Rack Selection Guide for
More informationQuickSpecs. HPE G2 Advanced Series Racks. Overview
HPE G2 Advanced Series Racks Overview HPE G2 Advanced Series Racks HPE G2 Advanced Series Racks are designed for low-to-medium density IT configurations deployed in a diverse set of environments from the
More informationPowering Change in the Data Center. A White Paper from the Experts in Business-Critical Continuity TM
Powering Change in the Data Center A White Paper from the Experts in Business-Critical Continuity TM Executive Summary Increases in data center density and diversity are driving change in the power and
More informationCabling Best Practices Using Fast Channel TM Switch Connect. Marc Dunham, Methode - Data Solutions
Cabling Best Practices Using Fast Channel TM Switch Connect Marc Dunham, Methode - Data Solutions ABSTRACT With the continued growth of port count density in data center hardware, end users are presented
More informationRole of Copper Cabling in Datacentres
Role of Copper Cabling in Datacentres White paper White Paper Role of Copper Cabling in Datacentres v1.0 EN 1 Introduction Structured cabling certainly has its place in contributing to the making of a
More informationData Center Market Transformation from On Premises to Colocation & Cloud. Tom Kelly & Tom Walsh/ 6 March 2018
Data Center Market Transformation from On Premises to Colocation & Cloud Tom Kelly & Tom Walsh/ 6 March 2018 The C ustomer C hallenge The C ustomer C hallenge What Applications are deployed where? Email
More informationS-Series Superior Rack Solution for Data Centre & Network Closets
S-Series Superior Rack Solution for Data Centre & Network Closets s-series rack Your mission-critical networks are carrying an ever increasing amount of voice, data and video. Your business relies heavily
More informationRE Series Rack from Eaton Product Presentation
RE Series Rack from Eaton Product Presentation AUG 2018 Quick Overview What is Eaton s RE Series Rack Platform? RE Series is an amalgamation of the NR & RE Series with many value-add component enhancements;
More informationThermal management. Thermal management
Thermal management Thermal management Managing thermal loads is a major challenge for all Data Centre operators. Effecting proper control of the thermal environment drives energy consumption and ultimately
More informationIntelligent-Remote Monitoring (3) Environmental Port (4) Power Outlet Level (5)
Faster. Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with Local and Intelligent PDU mounted display option for local current or power monitoring, making phase balancing easier
More informationCabinet Solutions
BRC_Cabinet_B.qxp_B 3/15/18 10:25 AM Page 2 S I EM ON Cabinet Solutions WWW.SIEMON.COM BRC_Cabinet_B.qxp_B 3/15/18 10:25 AM Page 3 8 IT IS ALL ABOUT MAXIMIZING SPACE AND EFFICIENCY Space utilization and
More informationIBM. Rack Installation Instructions
IBM Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following:
More information16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units SPECIFICATION SHEET specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to
More informationRack Installation Instructions
Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following: v Two
More informationSystems and Technology Group. IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development
Systems and Technology Group IBM Technology and Solutions Jan Janick IBM Vice President Modular Systems and Storage Development Power and cooling are complex issues There is no single fix. IBM is working
More informationV.I.B.E. Virtual. Integrated. Blade. Environment. Harveenpal Singh. System-x PLM
V.I.B.E. Virtual. Integrated. Blade. Environment. Harveenpal Singh System-x PLM x86 servers are taking on more demanding roles, including high-end business critical applications x86 server segment is the
More information16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
16 and 32 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent
More informationPowerware Enclosure Solutions Product Focus
Powerware Enclosure Solutions Product Focus Powerware Enclosures IT availability and reliability are critical corporate issues in today s demanding, mission-critical environments. For this reason, it is
More informationHassle-free equipment installation
12U 36in Knock-Down Server Rack Cabinet with Casters StarTech ID: RK1236BKF This server rack provides 12U of storage space in a sleek secure cabinet for storing EIA-310 compliant 19 rackmount devices such
More informationCabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity
Cabling Solutions for Nexus 9000 Switches With Dual-Rate 40/100G BiDi Transceiver and Panduit Connectivity Introduction Virtualization and cloud technologies have applied an incredible amount of pressure
More informationTwo-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center
Two-Stage Power Distribution: An Essential Strategy to Future Proof the Data Center Adapting to Change Concern over the pace of technology change is increasing among data center managers. This was reflected
More informationProduct Overview >> Cisco R Series Racks: Make Your Infrastructure Highly Secure. Has an innovative design to deliver exceptional power, cooling, and cable management, as well as strength and stability
More informationPowerChain Management solutions. Enclosure Solutions
PowerChain Management solutions Enclosure Solutions Eaton Enclosures IT availability and reliability are critical corporate issues in today s demanding, mission-critical environments. For this reason,
More informationA Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution Architecture
A Scalable, Reconfigurable, and Efficient High Density Data Center Power Distribution White Paper 129 Revision 2 by Neil Rasmussen > Executive summary Significant improvements in efficiency, power density,
More informationHassle-free equipment installation
22U 36in Knock-Down Server Rack Cabinet with Casters StarTech ID: RK2236BKF This server rack provides 22U of storage space in a sleek secure cabinet for storing EIA-310 compliant 19 rackmount devices such
More informationEnabling Business Critical Continuity for Unified Communications. Andy Liu Product Manager, Asia Pacific
Enabling Business Critical Continuity for Unified Communications Andy Liu Product Manager, Asia Pacific Emerson Creating Technology and Solutions for a World in Action #1 AC & DC Power System #1 OEM Embedded
More informationPower and Cooling for Ultra-High Density Racks and Blade Servers
Power and Cooling for Ultra-High Density Racks and Blade Servers APC White Paper #46 Richard L. Sawyer Director of Data Center Technology American Power Conversion Company 2005 APC corporation What has
More informationDCIM Data Center Infrastructure Management
DCIM Data Center Infrastructure Management Part 3 Operational Management Moves Adds and Changes & Electrical Infrastructure November 5, 2013 Presented by Julius Neudorfer Sponsored by Today s Topics Operational
More informationHP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions
HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W
More informationData Center Assessment Helps Keep Critical Equipment Operational. A White Paper from the Experts in Business-Critical Continuity TM
Data Center Assessment Helps Keep Critical Equipment Operational A White Paper from the Experts in Business-Critical Continuity TM Executive Summary The IT infrastructure within many companies has evolved
More informationVersaPOD and V600. Cabinets. Section Contents. VersaPOD AND V600 CABINETS
VersaPOD AND V600 CABINETS VersaPOD and V600 Cabinets Including both the innovative VeraPOD family of data center solutions and V600 24-inch (600mm) server cabinets, Siemonʼs comprehensive line of cabinets
More informationInstalling the Cisco MDS 9020 Fabric Switch
CHAPTER 2 This chapter describes how to install the Cisco MDS 9020 Fabric Switch and its components, and it includes the following information: Pre-Installation, page 2-2 Installing the Switch in a Cabinet
More informationQuickSpecs. Models. HP StorageWorks Modular Smart Array 30 Multi-Initiator (MSA30 MI) Enclosure. Overview
Overview (Supporting HP-UX and 64 Bit Linux Operating Systems on HP Integrity and HP 9000 Servers only) (Supporting HP-UX and 64 Bit Linux Operating Systems on HP Integrity and HP 9000 Servers/Workstations
More informationRack 111 Catalog. Designed and Built to Exceed Your Needs.
Designed and Built to Exceed Your Needs. The Open Frame Server Rack is designed to provide users with a customizable solution engineered to meet a diverse set of rack mounting needs. This EIA server rack
More informationQuickSpecs. HPE G2 Advanced Series Racks. HPE G2 Advanced Series Racks. Overview
Overview are designed for lowtomedium density IT configurations deployed in a diverse set of environments from the data closet to the data center. Following EIA310 specifications for 19 inch racks, G2
More informationNetfinity White Paper Netfinity Technology Center
Netfinity White Paper Netfinity Technology Center Rack Storage Expansion Enclosure Planning Guide Abstract This paper is designed for use by Pre-Sales technical marketing representatives. This includes
More informationIntelligent-Remote Monitoring (3) Power Circuit Environmental Port (4) Power Outlet Level (5) PDU De-Rated Power Watts (W) PDU Nominal.
Enclosure Power Distribution Units (PDUs) (continued) PDU Selection: Basic, with ocal Monitoring and Intelligent Highly secure access with admin, control and view-only accounts Intuitive Ethernet-based
More informationCooling on Demand - scalable and smart cooling solutions. Marcus Edwards B.Sc.
Cooling on Demand - scalable and smart cooling solutions Marcus Edwards B.Sc. Schroff UK Limited Data Centre cooling what a waste of money! A 1MW data center needs 177,000,000 kwh in its lifetime of 10
More informationS-SERIES 2 Superior Rack Solution for Data Center & Network Closets
S-SERIES Superior Rack Solution for Data Center & Network Closets S-SERIES II RACKS AND CONTAINMENT Vertiv S-Series Rack The S-Series Rack is an innovative enclosure system that integrates your computing
More informationViable Options for Data Center Solutions. By Ning Liu Offering Group Panduit APJ
Viable Options for Data Center Solutions By Ning Liu Offering Group Panduit APJ Agenda Market Overview Data Center Challengers Business Drivers Data Center Standards Data Center Technologies Panduit Solutions
More informationPanduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA
Panduit PreConfigured Industrial Distribution Frame (IDF) Installation Instructions Part Numbers ZDF48-RA and ZDF48-EA ZDF48-6RA and ZDF48-6EA Figure 1: Industrial Distribution Frame (IDF) Equipment Elevation
More information4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions
4-Post and Universal Telco Frame (UTF) Rack Mount Kit Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server
More informationCisco Nexus 9396 Thermal Duct and Cabling Guide
Cisco Nexus 9396 Thermal Duct and Cabling Guide Thermal Duct Installation APPLICATION GUIDE Top of Rack (ToR) switches, such as the Cisco Nexus 9396, are designed to meet the server-access networking requirements
More informationQuickSpecs. HP Rack G2 Series. Overview
Overview HP sets the new standard for performance and value in the enterprise with the new 10000 G2 Series Rack family. This new enterprise-class rack combines unparalleled structural integrity, cooling,
More informationRack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches
. White Paper Rack-Level I/O Consolidation with Cisco Nexus 5000 Series Switches Introduction Best practices for I/O connectivity in today s data centers configure each server with redundant connections
More informationSYSTIMAX Rack and Cabinet Solution
SYSTIMAX Rack and Cabinet Solution The SYSTIMAX Rack and Cabinet Solution offer is designed for use in telecommunications equipment installations, providing our SYSTIMAX BusinessPartners and customers
More information16 and 32 Amp PanView iq TM (PViQ TM ) Switched with Per Outlet Monitoring and Environmental Power Outlet Units. specifications. technical information
SPECIFICATION SHEET specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management of the in-cabinet power usage. This system helps to quickly
More informationV800 Cabinet Solution
WWW.SIEMON.COM V800 Cabinet Solution 8 V800 Cabinet Lightweight Stability Design provides an extremely stable, high-capacity cabinet without excessive weight Integrated Side Panel Grounding Spring loaded
More informationCisco Introduces the Cisco Nexus 2232TM-E 10GE Fabric Extender
Product Bulletin Cisco Introduces the Cisco Nexus 2232TM-E 10GE Fabric Extender PB715278 Cisco is introducing the Cisco Nexus 2232TM-E 10GE Fabric Extender as part of the Cisco Nexus 2000 Series Fabric
More informationBUILDING NETWORK SOLUTIONS GUIDE
BUILDING NETWORK SOLUTIONS GUIDE designed to be better. INTEGRATED SOLUTIONS BUILDING NETWORK CHALLENGES Constantly evolving technologies are driving connectivity expectations and moving interactions to
More informationLenovo 42U 1200mm Deep Racks Product Guide
Lenovo 42U 1200mm Deep Racks Product Guide Lenovo 42U 1200 mm Deep Static and Dynamic Rack offerings are industry-standard 19-inch server cabinets that are designed for high availability server environments.
More informationEF-Series EuroFrame Gen 2 Cabinet System
Protecting your technology investment. EF-Series EuroFrame Gen 2 Cabinet System The new generation of EF-Series EuroFrame Cabinet is a reliable and economical cabinet solution that supports rack-mount
More informationPolar PDUs POWER MANAGEMENT
Polar Power Distribution Units (PDUs) provide the ultimate solution for combining cabinet level power management, environmental monitoring, and cabinet access control in multi-tenant and enterprise data
More informationRack Installation Instructions
Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server in a rack cabinet, review the following guidelines:
More informationQuickSpecs. HP Rack G2 Series - top view
DA - 12402 Worldwide Version 6 3.8.2007 Page 1 Overview HP sets the new standard for performance and value in the enterprise with the new 10000 G2 Series Rack family. This new enterprise-class rack combines
More information15 Ways Belden Helps Reduce Human Error to Improve Uptime
15 Ways Belden Helps Reduce Human Error to Improve Uptime Up to 75% of data center downtime is caused by human error. While no data center is capable of being completely immune to mistakes, implementing
More informationHP Modular Cooling System: water cooling technology for high-density server installations
HP Modular Cooling System: water cooling technology for high-density server installations technical brief Abstract... 2 Introduction... 2 Data center trends... 2 Increased power demands... 3 Increased
More informationQuickSpecs. HP Rack G2 Series Overview
Overview HP sets the new standard for performance and value in the enterprise with the new 10000 G2 Series Rack family. This new enterprise-class rack combines unparalleled structural integrity, cooling,
More informationCall Guide. Transform. Transform The Network. Scenario 1: Hunting the opportunity. The Network
Transform Transform Call Guide Offer your customers best in class products on a range of Switches, Wireless and Data Centre Servers/Switches. Below, you ll find sales scenarios to help you during sales
More informationRacks and Cable Management
Racks and Cable Management Siemon s line of open racks and cable management solutions covers nearly any network infrastructure need: 4-post and 2-post racks, exclusive rack-mount vertical cable managers,
More informationWhite Paper. Physical Infrastructure for a Resilient Converged Plantwide Ethernet Architecture
White Paper March 2017 Physical Infrastructure for a Resilient Converged Plantwide Ethernet Architecture Successful deployment of CPwE logical architecture depends on a robust physical infrastructure network
More informationIBM Integrated Server Farm (ISF)
IBM Integrated Server Farm (ISF) TSS HW Services 05/04/2005 Data Centre Trends The density of computing power in a data centre environment has steadily increased in recent years. This trend is driven by
More informationCisco UCS Mini. Edge-Scale Computing with Enterprise Capabilities. Rebecca Awde Cisco DC Specialist.
Cisco UCS Mini Edge-Scale Computing with Enterprise Capabilities Rebecca Awde Cisco DC Specialist rawde@cisco.com Edge-Scale Computing Needs At the Edge of Large IT Enabling Small-Scale IT Central IT Small
More information1.866.TRY.GLCC WeRackYourWorld.com
cool it. 1.866.TRY.GLCC WeRackYourWorld.com In order to maximize space in the data center and accommodate for increased data, rack-mount enclosures are becoming populated with high-density servers and
More informationAPC InfraStruXure Solution Overview
APC InfraStruXure Solution Overview We re waiting for your call or email. 800--0 uptime@uptimeu.com Wiring Closets ( Racks) Small Server Rooms ( Racks) Small Data Centers ( 0 Racks) Medium Data Centers
More informationEIA 310-D. RAL 9005 black textured, low-gloss polyester powder paint over pretreated steel.
763.422.2588 Spec-00525 M763.422.2661 Free-Stand Cabinets PROLine Network s Free-Stand Cabinets PROLINE Network s PROLINE Network INDUSTRY StandardS EIA 310-D APPLICATION PROLINE Network Switch cabinet
More information30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
30, 50, and 60 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent
More information20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units
20 Amp PanView iq TM (PViQ TM ) Switched and Environmental Power Outlet Units specifications PViQ Power Outlet Units shall integrate with the Panduit PIM Software Platform to enable intelligent management
More informationFibre Channel over Ethernet and 10GBASE-T: Do More with Less
White Paper Fibre Channel over Ethernet and 10GBASE-T: Do More with Less What You Will Learn Over the past decade, data centers have grown both in capacity and capabilities. Moore s Law which essentially
More informationImprove the appearance and accessibility of your rack
Vertical Cable Organizer with Finger Ducts - 0U - 3 ft. StarTech ID: CMVER20UF This 3-foot vertical cable manager gives you a simple and space-efficient way to organize the cables in your server rack.
More informationQuickSpecs HP Rack 5642
Overview The HP 5642 rack, specifically designed for the value minded customer, is a revolutionary new rack that is assembled by the customer presenting significant savings while still proving to be a
More informationSmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers
SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Energy and Environmental Monitoring for Small Data Centers SmartZone Rack Energy Kits Features:
More informationHPE BladeSystem c3000 Enclosure Quick Setup Instructions
HPE BladeSystem c3000 Enclosure Quick Setup Instructions Part Number: 446990-007 2 Site requirements Select an installation site that meets the detailed installation site requirements described in the
More informationRack Installation Instructions
Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server in a rack cabinet, review the following guidelines:
More informationInstallation Notes and Warnings for the Cisco UCS 5108 Server. The following notes and warnings apply to all installation tasks:
This chapter contains the following sections: Notes and Warnings for the Cisco UCS 5108 Server Chassis, page 1 Installing the Chassis, page 6 Repacking the Chassis, page 20 SFP+ Transceivers, page 20 Notes
More informationPOWER CABLES FOR MISSION CRITICAL FACILITIES
POWER CABLES FOR MISSION CRITICAL FACILITIES UL LISTED, MISSION-CRITICAL POWER CABLES MANUFACTURED AND TESTED IN A CONTROLLED ENVIRONMENT With 24-Hour Turn-Around, an unprecedented number of receptacles,
More informationGreen IT and Green DC
Green IT and Green DC Alex SL Tay Regional Service Product Line Manager Site & Facilities Services, IBM ASEAN 1 What our clients are telling us We are running out of space in our data center We have environmental
More informationInstaPATCH Cu Cabling Solutions for Data Centers
SYSTIMAX Solutions InstaPATCH Cu Cabling Solutions for Data Centers Design Guidelines August 2008 www.commscope.com Contents Overview 1 InstaPATCH Cu Solution Specification 2 Harness Assembly Design 3
More informationData Centre In A Box
Data Centre In A Box Data Centre In A Box Rittal s Data Centre In A Box replicates all of the key data centre capabilities but on a smaller scale. The Data Centre In A Box mitigates risk and provides compelling
More informationE1135C PDU and Pod Upgrade Procedure
E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support
More information1. Unpacking the System
1. Unpacking the System To prevent shipping damage the system is packed in multiple boxes. Chassis The chassis in shipped in one box by itself. The chassis is shipped assembled. Inside the chassis you
More informationMoving Containment Inside the Enclosure. Jeff Markle Great Lakes Case & Cabinet
Moving Containment Inside the Enclosure Presented by Jeff Markle Great Lakes Case & Cabinet Containment Containment : To put constraint upon; to restrain; to confine; to keep within bounds Containment
More information