SERIES 230 C2ADTL Transfer Switch User Manual
|
|
- Amice Pearson
- 5 years ago
- Views:
Transcription
1 SERIES 230 C2ADTL Transfer Switch User Manual Version V1.2 Revision Date Feb 25, 2013 BOM Code Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson Network Power sales office or service center. Copyright 2012 by Emerson Network Power Co., Ltd. All rights reserved. The contents in this document are subject to change without any prior notice. Emerson Network Power Co., Ltd. Address: No.1 Kefa Rd., Science & Industry Park, Nanshan District , Shenzhen China Website: Customer Service Hotline:
2
3 Contents Chapter 1 Overview Model Description and Order Information Model Description Configuration Description and Number of Poles Accessory Model Description and Order Information Appearance Product Composition Panel Description Application Environment Technical Parameters... 5 Chapter 2 Installation And Operation Installation Installation of Transfer Switch Accessory Installation Operation Manual Operation Auto Operation Padlock Chapter 3 Maintenance and Troubleshooting Start Up / Function Test Maintenance Common Troubleshooting Appendix 1 Surge Protection Device Appendix 2 Glossary... 20
4
5 Chapter 1 Overview 1 Chapter 1 Overview ASCO Series 230 C2ADTL transfer switch is a professional PC class dual power transfer switch. It adopts a reliable mechanism and an electric design built on a modular concept, and is suitable for various electric continuity applications. All Series 230 transfer switch products meet EN and IEC requirements. This chapter will introduce the model description, appearance, product composition, application environment and mechanical parameters of this transfer switch. 1.1 Model Description and Order Information Model Description Taking C2ADTLB30250HE00 as an example, the model description is shown in Table Table 1-1 Model Description and Order Information C2ADTL B H E Series 230 C2ADTL Automatic Transfer Switch Number of Poles, Configuration Rated Operating Current Code Rated Operating Voltage Code Controller Accessory C2ADTL B1 Description Series 230 C2ADTL Automatic Transfer Switch Center-off (three-position design) 2 Poles (Sigle Phase 220V-240V, 2-Wire with Neutral Line) 02 2 Poles (Two Phase 220V-240V, 2-Wire without Neutral Line) B2 3 Poles (Two Phase 220V-240V, 3-Wire with Neutral Line) 03 3 Poles (Three Phase 380V-415V, 3-Wire without Neutral Line) B A A A A A A A A A A A A A A D E F H J K D E 4 Poles (Three Phase 380V-415V, 4-Wire with Neutral Line) 220V 230V 240V 380V 400V 415V C1000 Controller C2000 Controller 0 No accessory 7 Enclosure 0 No enclosure X With accessory, Such as: Auxilianry Contact 132A~132F Notes: Default frequency setting is 50Hz. If application frequency requires 60Hz, please indicate this when ordering Series 230 product.
6 2 Chapter 1 Overview Configuration Description and Number of Poles Accessory Model Description and Order Information Auxiliary Contacts (Optional Accessory) 132 A A Auxiliary Contact Quantity Blank: 1 Contact A: 2 Contacts B: 3 Contacts C: 4 Contacts Function Code (See Diagram Below) 132A-132F: Auxiliary Contact Auxiliary Contact For example: 132BA, means 2 contacts, closed when the ATS transfer to source II position. The Auxiliary Contact Code Definitions 132A-132C : The auxiliary contacts can be used to indicate positions with the CLOSE contact, see Schematic D-132F: The auxiliary contacts can be used to indicate positions with the OPEN contact, see Schematic 2. Position of The transfer switch Auxiliary Contact Function Code Position of The transfer switch Auxiliary Contact Function Code Schematic 1 132A-132C Diagram Schematic 2 132D-132F Diagram
7 Chapter 1 Overview Appearance The appearance of the transfer switch is shown in Figure 1-1. Figure 1-1 Appearance 1.3 Product Composition Series 230 automatic transfer switch includes one transfer switch and one controller. The C2ADTL Size has multiple ampere rating options. Series 230 transfer switch unit can work with either the C1000 or C2000 controller. The following accessories are included as standard in the Series 230 C2ADTL automatic transfer switch package, see Table 1-2: Table 1-2 Series 230 C2ADTL Transfer Switch Standard Accessories Standard Accessories Model and Specification Part Number 2-Pole 3-Pole 4-Pole Mounting Fastener Package M Pack 1 Pack 1 Pack Terminal Screws M Terminal Washers D Terminal Nuts M pcs 12 pcs 16 pcs Bridging Busbar LBP1F pcs 3 pcs 4 pcs Pole Partition LIP1F pcs 8 pcs 12 pcs Handle LHS3F pcs 1 pcs 1 pcs Connection Cable Power Cable & Signal Cable set 1 set 1 set Fuse MXP/UDA pcs 2 pcs 2 pcs User Manual Series 230 C2ADTL Transfer Switch User Manual copy 1 copy 1 copy The following accessories are included as optional in the Series 230 C2ADTL automatic transfer switch package, see Table 1-3: Table 1-3 Series 230 C2ADTL Transfer Switch Optional Accessories Function Code Accessories Name Model and Specification Part Number Quantity 132A,132AA,132AB,132AC Auxiliary Contact (NO) LAP1F ,2,3, or 4 132B,132BA,132BB,132BC Auxiliary Contact (NO) LAP1F ,2,3, or 4 132C,132CA,132CB,132CC Auxiliary Contact (NC) LAP1F ,4,6, or 8 132D,132DA,132DB,132DC Auxiliary Contact (NC) LAP1F ,2,3, or 4 132E,132EA,132EB,132EC Auxiliary Contact (NC) LAP1F ,2,3, or 4 132F,132FA,132FB,132FC Auxiliary Contact (NO) LAP1F ,4,6, or 8 Note: The optional accessories are an additional order item.
8 4 Chapter 1 Overview 1.4 Panel Description For the transfer Switch panel description, see Figure 1-2. Source I Line Side Arc Chamber Source II Line Side Fuse Position Indicator Window Nameplate Label Auxiliary Contact Mounting Positions Label Cover Auto/Manual Toggle Switch Padlock Pull Tab Operating Handle Hole Source I Load Side Source II Load Side Figure 1-2 Panel Description 1.5 Application Environment Altitude: 2000 meter or less Temperature: -5 C to +40 C Humidity: Within 95%, No condensation Pollution Class: Class III Mounting Method: Horizontal or Vertical Product Standards Met: EN and IEC Environmental Standards Met: RoHS and WEEE
9 Chapter 1 Overview Technical Parameters For the technical parameters, see Table1-4. Table 1-4 Technical Parameters Item Rated Operating Voltage Ue (Vac) Operating Voltage Range (V) 220 / 230 / 240(2 poles) Parameter 380 / 400 / 415(3 poles / 4 poles) Ue=220 / 230 / 240 / 380 / 400 Ue= 415 (0.7~1.2) Ue (0.7~1.15) Ue Utilization Category AC-33B Rated Insulation Voltage Ui (V) 800 Rated Impulse Withstand Voltage Uimp (kv) 12 Rated Short-time Making Capacity Icm (peak) (ka) 31.5 Rated Short-circuit Withstand Current Icw (ka/0.1s) 15 Rated Conditional Short-circuit Current Iq (rms) (ka) 200(FUSE)/150(MCCB) Operating Transfer Time (s) <2.5
10 6 Chapter 2 Installation And Operation Chapter 2 Installation And Operation! DANGER DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.! WARNING WARNING is used in this manual to warn of a hazardous situation which, if not avoided, could result death or serious injury.! CAUTION CAUTION is used in this manual to warn of a hazardous situation which, if not avoided, could result in minor or moderate injury. NOTICE NOTICE is used in this manual to comments or suggestion of a fault situation which, if not avoided, could result in fault. An experienced licensed electrician must install the ATS. Each automatic transfer switch contains a rating label (Name plate) to define the loads (Ampere rating). Refer to the label on the transfer switch for specific values.! DANGER Do not exceed the values on the rating label. Exceeding the rating can cause personal injury or serious equipment damage.
11 Chapter 2 Installation And Operation Installation 1. Connect with the controller See the corresponding controller user manual for controller installation details. 2. Connect Surge Protection Device The Automatic transfer switch is connected to an electronic circuit with a power supply, that is vulnerable to overvoltage damage, therefore, it is recommended that users install Class C Surge Protection Devices when using automatic transfer switches, and the right wiring methods. See Appendix 1 (Surge Protection Device) for additional details and recommended wiring methods Installation of Transfer Switch Install the transfer switch to the cabinet according to the mounting dimensions shown in Figure B A C Figure 2-1 Mounting Dimension (unit: mm)! WARNING Recommended torque to be used for transfer switch mounting screws during installation: M5: 3N m. Dimensions of A, B, and C in Figure 2-1 are shown in Table 2-1.
12 8 Chapter 2 Installation And Operation Table 2-1 A, B, and C Dimensions 2 Pole 3 Pole 4 Pole A (mm) B (mm) C (mm) Weight (KG) Accessory Installation 1. Bridging Busbar It is used to connect the switch I and II load side terminals together. The installation procedures are as follows: 1) Identify the transfer switch load side terminals. 2) As shown in Figure 2-2, insert the bridging busbar between the Source I load side terminal and the Source II load side terminal with the long center plate of bridging busbar against the arc chamber wall surface. 3) Fix the bridging busbar with M10 30 terminal screws included with the package. Source II Load Terminal Load Connection busbar Bolt assembly Source I Connection busbar Load Side Washer Nut Line Side Source II Load Terminal Bridging busbar Source II Connection busbar Figure 2-2 Installation of Bridging Busbar! WARNING 1. Make sure to install the bridging busbar in such a way that its long center plate must make solid contact with the arc chamber surface. 2. The bridging busbar can only be used for the LOAD SIDE of the switch. 3. Recommended torque to be used for the bridging busbar connecting screws: M8: 11N m. 2. Pole Partition The pole partition is used to isolate and insulate the poles and ensure electric safety. The installation procedures are as follows: 1) The pole partition as shown in Figure 2-3. Gap Figure 2-3 Pole Partition
13 Chapter 2 Installation And Operation 9 2) Remove all label covers on the arc chamber: A/B/C/N. Insert the first pole partition between two arc chambers with the gap facing DOWN and insert another pole partition with the gap facing upward. Repeat for each slot between each pole. When finished, snap each label cover back into its original position. Make sure that the correct label (LINE versus LOAD) is showing on the correct side. See Figure 2-4 for more details. Label Cover Line Side Gap A B C N Gap Gap Down Load Side Gap Figure 2-4 Pole Partition Installation! CAUTION 1. The gap in the pole partition is used to make room for the label covers and the base of the switch. If the gap is inserted in the wrong direction, the label cover will not be able to be snapped back into position correctly. 2. Make sure that the correct label (LINE versus LOAD) is showing on the correct side AND make sure that the corresponding phase labels on the cover (A/B/C/N) are in their correct positions as well with A Phase being closest to the main gear driver box area. 3. Auxiliary Contacts (Optional Accessory) There are many different optional auxiliary contact configurations available for the C2ADTL TS unit, See the Figure 2-5 below for what options exists. 132A 132AA 132AB 132AC 132B 132BA 132BB 132BC 132C 132CA 132CB 132CC
14 10 Chapter 2 Installation And Operation 132D 132DA 1 132DB 132DC 132E 132EA 132EB 132EC 132F 132FA 132FB 132FC Figure 2-5 Auxiliary Contact Order Code and Installation The Auxiliary Contact Locations are shown in Figure 2-6. Location I Auxiliary Contact Mounting Location II Auxiliary Contact Mounting The installation procedures are as follows: Figure 2-6 Auxiliary Contact Location Definition 1. With the auxiliary contact screw holes facing outward, snap the 4 claws into the corresponding 4 holes on the transfer switch side plate, and then force it into position, as shown in Figure 2-7.
15 Chapter 2 Installation And Operation 11 Screw Hole Face Out Screw Hole Face Out Figure 2-7 Auxiliary Contact Installation to Side Plate 2. When mounting an additional auxiliary contact on top of another contact, remove the sticker located in the center of the contact that is being mounted, then like before, with the screw holes facing outward, snap the 4 claws into the corresponding 4 holes on the previously installed auxiliary contact and then force it into position, as shown in Figure 2-8. If installing an additional auxiliary contact on top of another, need to remove sticker on the base auxiliary contact, otherwise do not remove sticker to protect auxiliary contact from dust debris. Sticker No Sticker Sticker Figure 2-8 Auxiliary Contact Installation on Top of Another Contact NOTICE 1. The center sticker on the auxiliary contact that is in direct contact with the side plate must be removed before installation of the additional auxilary contact on top of it. 2. Keep the center sticker on the outer most auxiliary contact in place to avoid any debris or dust from getting inside. 3. The maximum auxiliary contacts that can be used on the side plate are 8 contact s, or 2 contacts per slot location. There are 4 slot locations. 3. Next, punch out the small holes on the side plate in order to insert the cable clamps into the small round holes on the transfer switch side plate. See figure 2-9. There should be 2 clamps packaged together with each optional auxiliary contact. Figure 2-9 Cable Clamp 4. After wiring the auxiliary contacts, affix the corresponding cable with the closest cable clamp using a cable tie to facilitate and optimize the wiring layout as shown in Figure 2-10.
16 12 Chapter 2 Installation And Operation Punch out the small holes, Then insert cable clamp 5. Auxiliary Contact Specifications: a) Ratings: Figure 2-10 Schematic Diagram for Cable Routing Rated thermal current Ith /A Rated insulation voltage V Rated impulse withstand voltage Uimp/kV Protection class of enclosure Pollution degree Maximum cable cross section IP mm 2 b) Additional Information: AC-15 DC-12 DC-13 U e / V I e / A U e / V I e / A P / W I e / A P / W ! CAUTION In order to obtain higher reliability, the auxiliary contact circuit should meet the requirments: Current 5mA
17 Chapter 2 Installation And Operation Operation Manual Operation The procedures are as follows: 1. Move the auto/manual toggle switch from AUTO (automatic) to MANUAL position, as shown in Figure Figure 2-11 Switching the toggle Switch from AUTO to MANUAL! CAUTION Make sure toggle switch lines up with the correct indication position mark Indication Position Mark 2. Insert the operating handle into the handle hole, and rotate the handle according to the position and direction shown in the position indicator widow. 1) When the window initially displays OFF (Center-off Position), do the following operations as needed: If you need to switch to Position I (Normal Source), rotate the handle 90 degrees counter-clockwise. After hearing a click', and the window displays I, it indicates that the position has been successfully switched to Position I. If you need to switch to Position II (Emergency Source), rotate the handle 90 degrees clockwise. After hearing a click', and the window displays II, it indicates that the position has successfully switched to Position II. 2) When the window initially displays I (Normal Source), do the following operations as needed: If you need to switch it to the Position OFF (Center-Off Position), rotate the handle 90 degrees clockwise. After hearing a 'click', and the window displays OFF, it indicates that the position has successfully switched to Position OFF. If you need to switch it to Position II (Emergency Source), rotate the handle 180 degrees clockwise. After hearing a 'click, and the window displays II, it indicates that the position has successfully switched to Position II. 3) When the window initially displays II (Emergency Source), do the following operations as needed: If you need to switch it to the OFF Position (Center-off Position), rotate the handle 90 degrees counter-clockwise. After hearing a 'click', and the window displays OFF, it indicates that the position has successfully switched to the Position OFF. If you need to switch it to Position I (Normal Source), rotate the handle 180 degrees counter-clockwise. After hearing a 'click', and the window displays I, it indicates that the position has successfully switched to Position I. The detailed handle rotation positions are shown in Figure 2-12.
18 14 Chapter 2 Installation And Operation I (Normal Source) OFF (Center-off Position) II (Emergency Source) I (Normal Source) II (Emergency Source) OFF (Center-off Position) If Initial Position is Position OFF If Initial Position is Position I If Initial Position is Position II Figure 2-12 Switch Rotation Diagram! CAUTION 1. If the toggle switch is not in the right position (MANUAL), the handle cannot be inserted. 2. The manual handle operation torque should more than 16Nm. 3. Due to high torque of the handle during operation, the operator should be careful to avoid from getting injured from touching the toggle switch and padlock pull tab objects portruding from the surface Auto Operation 1. Remove the operating handle from the handle hole. 2. Move the auto/manual toggle switch from MANUAL to AUTO Position, as shown in Figure Figure 2-13 Switching Toggle from MANUAL to AUTO! CAUTION Make sure toggle switch lines up with the correct indication position mark Indication Position Mark 3. Once auto/manual toggle switch is in the 'AUTO' Position, the switch will automatically transfer to the position that is currently set in the controller. (For a description of how to set the positions in the controller, refer to the Series 230 C1000 Controller User Manual or Series 230 C2000 Controller User Manual) Padlock! WARNING 1.If the handle has not been removed, the auto/manual toggle switch cannot be switched to the 'AUTO' Position. 2.After the manual operation, the operator must ensure that the auto/manual toggle switch moves back to the 'AUTO' Position, and the auto/manual toggle switch lines up with the 'AUTO' Position indicator mark. Otherwise, the transfer switch will not work in Automatic Mode. In order for the Padlock Pull Tab to function properly, one must ensure that the switch is in Manual Mode AND the handle is in the Position Off. To do this, do the following in this order: 1. Ensure that the auto/manual toggle switch is in MANUAL position.! CAUTION If the auto/manual toggle switch is not in MANUAL position, the padlock pull-tab cannot be pulled up.
19 Chapter 2 Installation And Operation Ensure that OFF is displayed in the position indicator window. If not, use the manual operating handle to switch the transfer switch to Position OFF according to the directions shown in the position indicator window.! CAUTION When the switch is not in OFF Position, the padlock pull-tab cannot be pulled in place. 3. Finally, pull the padlock pull-tab out and lift up to expose the lock hole. Then insert the proper padlock into the hole to lock it.! CAUTION The specified diameter of the C2ADTL transfer switch padlock must be φ5mm to φ6mm.
20 16 Chapter 3 Maintenance and Troubleshooting Chapter 3 Maintenance and Troubleshooting This chapter describes the transfer switch installation, commissioning and common faults and maintenance methods. 3.1 Start Up / Function Test 1. To Test Manual Operation Two power supply Sources must be disconnected before manual testing can begin. Refer to chapter to run Manual Operation mode. Operate the transfer switch from I position to II position and turn back to I position with handle. The operation should be smooth, without interruption. If so, switch is operating correctly in manual mode. 2. To Verify Voltage Detection First make sure the rated voltage of the transfer switch on the nameplate is the same as the dual-power supply rated voltages. Next, review the C2000 or the C1000 controller, to make sure the power is being supplied to transfer switch. Source I and Source II Auxiliary Indication LED lights are on (green), This should indicate your wiring is correct. If using the C2000 controller, Double-check and measure the dual-supply voltage, to make sure voltages are consistent to what is indicated on the C2000 controller.! DANGER When measuring Voltage, pay attention to not touch the terminals and copper bars, otherwise it could result in death, or serious injury. 3. To Test Electric Operation This is used to test the controller in electric operation mode and operate the transfer switch electrically. Using C2000 controller: Menu Setting 2. Settings Control Menu Operation Description Up Enter Down Settings Scrolling the main menu to Setting,and press Enter button. 2.4 Control Mode S1 Prior Up Down Control Mode Scrolling the Setting menu to Control Mode,and press Enter button. The Control Mode Menu will display the last settings.for example,the default control mode is S1 Prior. Enter 2.4 Control Mode Manual Control Up Enter Down Control Mode Scrolling the Control Mode menu to Manual Control,and press Enter button.and then setting is ok,system will be reset. Must press the Enter button when the Control Mode is setted,the contorller will be reset to complete the set.
21 Chapter 3 Maintenance and Troubleshooting 17 Once you, successfully set up the manual control mode, the Auto LED on the controller panel will blink. (1) Electric Operation Test The transfer switch can now transfer and return. The operation should be smooth. Description of the operation is as follows. 7. Manu Control Manu Action Up Enter Down Menu Operation Description Manu Control Scrolling the main menu to Manu Control,and press Enter button. 7.1 Switch Ctrl Action Up Down Switch Ctrl Next,Scrolling the menu to Switch Control,and press Enter button. Enter 7.1 Switch Ctrl X->II Up Enter Down Switch Ctrl Then Scrolling the menu to the target location,such as the transfer switch is in location I,scrolling the menu to X II and press Enter button,the switch should be transferred to Location II. Operate the switch again,it can be tansferred to Location I,Location OFF or Location II.If the switch is in Location I,scrolling the menu to X I and press Enter,the switch will not tranfer. (2) Return To The Original Control Mode settings. After completing the electric operation test, you can return to the original control mode by using the menu Using C1000 Controller: (1) According to The 230 Series Automatic Transfer Switch C1000 Intelligent Controller User Manual, the DIP 7-8 is set to ON, ON, the run LED will blink, and one of the switch s Position Indication LED s will blink, The controller is now in manual control mode. (2) The blinking LED is the target position that the switch will transfer to. Press the key less than 3 seconds, the position indication LED will blink alternately to show which position is target transfer. Choose a transfer target position. (3) Press the key 3 Sec, and the switch will transfer to the target position. (4) The switch can transfer and return by this method, and the operation should be smooth. (5) According to The 230 Series Automatic Transfer Switch C1000 Intelligent Controller User Manual, the DIP 7-8 is set to automatic or remote Mode, and the controller will exit manual control mode.
22 18 Chapter 3 Maintenance and Troubleshooting 3.2 Maintenance To ensure consistent reliability of the transfer switch to make sure it is operating normally, regular maintenance testing should be conducted. It is recommended to do so once every three months. 3.3 Common Troubleshooting Table 3-1 Troubleshooting Guideline Troubleshooting Issues No response in auto mode The handle cannot be inserted in order to operate the switch manually. Once handle is inserted, one cannot operate the handle The auto/manual toggle switch cannot be set to 'AUTO' Position The padlock pull-tab cannot be pulled up Recommended Action Check if the auto/manual toggle switch is in 'AUTO' Position. Check if the wiring is routed correctly Check if the power supply meets the rated voltage range. Check if the fuse is properly installed and /or destroyed Check if the auto/manual toggle switch is in 'MANUAL' Position Check if the transfer switch has been locked. Check if the handle is turning in the correct direction based on Chapter Check if operator is applying enough force to handle (recommend operating torque is greater than16n m) Check to make sure the handle has been removed from the handle hole. Check to make sure the padlock pull-tab has been pushed all the way down to the original unlocked position. Check if OFF is displayed in the position indicator window. Check to make sure the auto/manual toggle switch is in 'MANUAL' Position For all other issues, please contact Emerson Network Power. Check and Replace Fuse: 1. Before checking the condition of the fuse, the operator MUST switch the manual/auto toggle switch to the 'MANUAL' Position. 2. Then, the operator can open the fuse housing cover, take out the fuse, and check the fuse resistance by ohmmeter or multi-meter to determine if fuse is blown out or not. 3. If fuse is blown out (damaged), then replace it using an equivalent rated fuse. For more information, go to Table 1-2. Finally, close the fuse housing cover. 4. After new fuse has been replaced, and if the operator wants to use Auto Mode, then switch the manual/auto toggle switch back to the 'AUTO' Position.! DANGER 1. Only a professional electrician should operate to check and replace the the fuse. Such a person MUST be equiped with insulated rubber boots, insulated gloves, and insulated tools. 2. Before removing the damaged fuse, the operator MUST switch the manual/auto toggle switch to the 'MANUAL' Position.
23 Appendix 1 19 Appendix 1 Surge Protection Device 1. In order to run the Automatic Transfer Switch reliably, SPD s are needed before connecting the Automatic Transfer Switch to Source I and Source II. It is recommended that the SPD wire connections use V shape wiring method shown in Appended Figure 1. When limited by practical conditions, and if it is difficult to adopt V shape wiring, one can also use routine direct-parallel-connection method shown in Appended Figure 2. The connection wire should be as short as possible (less than 0.5m) when using direct-parallel-connection method to achieve better protective performance. 2. The connection wires should be multi-core copper wire with a cross-sectional area greater than 10mm 2 (AWG6). 3. Appropriate MCB or Fuse should be serial-connected to the front-end of the SPD for AC power supply. The MCB should have the C tripping characteristic. 4. The power supply should be cut off when installing SPD s. Live installation is prohibited. All the wires must be connected properly, and using correct wires. 5. While the SPD does not need special maintenance, it is recommended that one periodically checks whether the indicators of the SPD are functioning normally and to make sure the modules are not loose. 6. If either of the following situations appear, the SPD has failed and needs to be replaced. 1) The SPD indicator turns red. 2) The SPD remote signal contact becomes an open-circuit. 7. The Wiring method show in Appended Figure 3 is forbidden. If SPD is wired similar to Appended Figure 3, the wiring needs to be modified to Appended Figure 1 or Appended Figure 2. Source I L1 L2 L3 N MCB or Fuse Surge Protection Device Wiring from Main Circuit to Grand lenth 0.5m Class C Surge Protection Device Connection Wiring Lenth 1m Series230 Transfer Switch Load Source I L1 L2 L3 N MCB or Fuse Surge Protection Device Wiring from Main Circuit to Grand lenth 0.5m Class C Surge Protection Device Connection Wiring Lenth 1m Series230 Transfer Switch Load L1 Source L2 II L3 N Connection Wiring Lenth 1m Source II L1 L2 L3 N Connection Wiring Lenth 1m MCB or Fuse Surge Protection Device Wiring from Main Circuit to Grand lenth 0.5m Class C Surge Protection Device Cable line 2m Grouding Cable Lenth 0.2m Controller MCB or Fuse Surge Protection Device Wiring from Main Circuit to Grand lenth 0.5m Class C Surge Protection Device Cable Line 2m Controller Grouding Cable Lenth 0.2 m Appended Figure 1: V Shape Wiring Method Appended Figure 2: Direct-Parallel-Connection Method Source I L1 L2 L3 N Connection Wiring Lenth 1m Series230 Transfer Switch MCB or Fuse Surge Protection Device Wiring from Main Circuit to Grand lenth 0.5m Class C Surge Protection Device Load L1 Source L2 II L3 N MCB or Fuse Surge Protection Device Wiring from Main Circuit to Grand lenth 0.5m Class C Surge Protection Device Connection Wiring Lenth 1m Cable Line 2m Controller Grouding Cable Lenth 0.2m Appended Figure 3: Wrong Connection Method
24 20 Appendix 2 Appendix 2 Glossary ATS NC NO Automatic Transfer Switch Normally Closed Normally Open
SERIES 230 A2ADTL Transfer Switch User Manual
SERIES 230 A2ADTL Transfer Switch User Manual Version V1.1 Revision Date Jan 12 th, 2018 BOM Code 31013293 ASCO Power Technologies provides customers with technical support. Users may contact the nearest
More informationSeries 230 Automatic Transfer Switch
Series 230 Automatic Transfer Switch The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Product Overview The Series 230 automatic transfer
More informationSERIES 230 Automatic Transfer Switch C1000 Intelligent Controller User Manual
SERIES 230 Automatic Transfer Switch C1000 Intelligent Controller User Manual Document Version V2.3 Archive Date Jan 12 th, 2018 BOM Code 31012665 ASCO Power Technologies provides customers with technical
More informationSeries 230 Automatic Transfer Switch
Series 230 Automatic Transfer Switch Global Headquarters-Florham Park, New Jersey ASCO was founded in 1888, and manufactured the first ATS in 1920, ASCO focuses on the development of ATS, and has become
More informationSeries 230 Automatic Transfer Switch
Series 230 Automatic Transfer Switch The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Application Product Overview The Series 230 automatic
More informationASCO SERIES 230 Automatic Transfer Switch
ASCO SERIES 230 Automatic Transfer Switch The Recognized Leader in Power Transfer Switch Technology Offers the Most Advanced Transfer Switches in the World. Application Product Overview The Series 230
More informationAutomatic Transfer Switch OTM_C_20D. Installation and Operation Instructions
Automatic Transfer Switch OTM_C_20D Installation and Operation Instructions Contents 1 SYMBOLS & TERMS... 1 1.1 USE OF SYMBOLS... 1 1.2 EXPLANATIONS OF ABBREVIATIONS AND TERMS... 1 2 PRODUCT OVERVIEW...
More informationAutomatic Transfer Switch OTM_C20D
v Read through this instruction carefully before working on the switch, and keep this instruction for later reference v The images provided in this instruction book are for illustration purposes only and
More informationSiemens AG SENTRON 3NJ4, 3NJ5 In-Line Fuse Switch Disconnectors up to 2000 A
Switch Disconnectors Introduction Overview All key product features at a glance Compliant with IEC/EN 60439-1, IEC/EN 6094-3 Voltage levels up to 690 V AC Rated operational current from 160 A to 2000 A
More informationC60PV-DC. IEC / EN e. Main characteristics Operating voltage (Ue) 800 V DC Rated insulation voltage (Ui) 1,000 V DC Breaking capacity (Icu)
DC circuit supplementary protectors for photovoltaic C60PV-DC PB108403-50 The C60PV-DC is a DC circuit breaker dedicated to multi string photovoltaic. This circuit breaker is designed to protect the cables
More informationXB7NS8442 Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC
Characteristics Emergency stop Ø 22 - red - mushroom head Ø 40 mm - turn to release - 1 NC Main Range of product Product or component type Device short name Mounting diameter Sep 4, 2018 Harmony XB7 Emergency
More informationXCKS141H29 limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20
Characteristics limit switch XCKS - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device
More informationThe power behind competitiveness. Delta Infrasuite Power Management. Power Distribution Unit. User Manual.
The power behind competitiveness Delta Infrasuite Power Management Power Distribution Unit User Manual www.deltapowersolutions.com Save This Manual This manual contains important instructions and warnings
More informationXB7NA4234 PB - Spring Rtn, red - 1NC -White "STOP"
Characteristics PB - Spring Rtn, red - 1NC -White "STOP" Main Range of product Product or component type Device short name Mounting diameter Sep 4, 2018 Harmony XB7 Push-button XB7 Sale per indivisible
More informationDRT-301 A/D. User manual. Three phase four wire DIN rail energy meter. (Seven modules) 1.1 Safety instruction. 1.2 Foreword. 1.3 Performance criteria
DRT-301 A/D Three phase four wire DIN rail energy meter (Seven modules) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Structure Diagram 1.7 Dimensions
More informationXB5AS8445 red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC
Characteristics red Ø40 Emergency stop, switching off Ø22 trigger latching turn release 1NO+1NC Main Range of product Product or component type Device short name Bezel material Fixing collar material Mounting
More informationArmorPoint I/O Field Potential Distributor, Series A
Installation Instructions ArmorPoint I/O Field Potential Distributor, Series A (Cat. No. 1738-FPD) The field potential distributor (Cat. no. 1738-FPD) lets you change the field power distribution source
More informationUser s Manual. ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1 200 HP)
More informationMOTOR PROTECTION CIRCUIT BREAKERS
MOTOR PROTECTION CIRCUIT BREAKERS PAGE -2 PAGE -2 SMA Thermal trip adjustment ranges 9-32A (5 choices) Breaking capacity Icu at 400V: 50kA Suitable for mounting in consumer switchboards with minimum 58mm
More informationLXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp. User manual
LXEM145 SERIES Lanx Australis single Phase KWh Meter 45Amp Single phase two wire DIN rail energy meter (One module) 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic
More informationQuick Start Guide TS A
Quick Start Guide TS 930 125-630A DANGER HAZARD OF ELECTRICAL SHOCK, EXPLOSION, OR ARC FLASH Read and understand this quick start guide before installing and operating the transfer switch The installer
More informationPRO-75 SERIES. User manual
PRO-75 SERIES DIN rail single phase two wire energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Description 1.7 Dimensions 1.8 Installation
More informationic60n RCBO 30 ma IEC , IEC , AS/NZS
ic60n RCBO 30 ma DB405571 Country approval pictograms IEC 61009-1, IEC 61009-2-2, AS/NZS 61009.1 PB110075-70 b The single-phase ic60n RCBO s self-contained residual current device provides protection of
More informationSOCOMEC SIRCOVER MANUALLY OPERATED CHANGEOVER SWITCHES
MANALL OPERATED CHANGEOER SWITCHES are manually operated multipolar changeover switches. They changeover between two low voltage power circuits under load and provide safety disconnection. Application:
More informationPRO-1250D CT MID DIN rail three phase four wire energy meter.
PRO-1250D CT MID DIN rail three phase four wire energy meter. 1.1 Safety instructions 1.2 Foreword 1.3 MID certificate 1.4 Performance criteria 1.5 Specifications 1.6 Basic errors 1.7 Description 1.8 Dimensions
More informationDigital ac/dc (24V) Input Module
Installation Instructions Digital ac/dc (24V) Input Module Catalog Number 1771-IND, Series C Topic Page Important User Information 2 Before You Begin 3 Power Requirements 3 Prevent Electrostatic Discharge
More information3RM1 Hybrid Starters 6SIRIUS. contents. Industrial Controls Product Catalog 2017
3RM1 Hybrid Starters Industrial Controls Product Catalog 2017 Section contents 3RM1 Compact - Hybrid Starters Overview /2 General Data /3 Selection and ordering data /4 Accessories /5 - /9 Technical Data
More informationCatalog Number Identification with Elements Explained V V V V X 347 V Hz
Owner s Manual 917 & 918 Remote Control Switches TABLE OF CONTENTS page Ratings & Installation... 1 2 Optional Accessories... 3 4 Troubleshooting & Parts Kits... 5 Wiring & Outline Diagrams... back of
More informationXTM1250SA DIN rail three phase four wire LCD display energy meter
XTM1250SA DIN rail three phase four wire LCD display energy meter 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Intrinsic errors 1.6 Description 1.7 Dimensions 1.8
More informationIntroduction Circuit Protection
Introduction Circuit Protection Weidmuller s DIN-rail mounted circuit breakers are available for use in applications where circuit protection must be able to distinguish between circuit overloads and short
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationControl unit SG-EFS 104/4L. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/4L AC/DC 24 V
Innovative by tradition. Control unit SG-EFS 104/4L EN Operating instructions Version 2 1004128 SG-EFS 104/4L AC/DC 24 V Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY
More informationK1C024B body for BCD encoded output switch - 1 pole A - for Ø 22 mm
Characteristics body for BCD encoded output switch - 1 pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Sub-assembly
More information63 to 125 A. Functions. Conformity standards. General characteristics. Changeover switches SIRCO VM1 changeover switches.
comut_004_a_1_cat Changeover switches switches 63 to 125 A switches are manually operated three or four pole switches. They provide, source inversion or switching under load between two low voltage power
More informationXB7NG33 key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center
Characteristics key selector switch - Ø 22 - keylock - 3 positions - 2 NO - Ronis 455 center Main Range of product Product or component type Device short name Mounting diameter Oct 4, 2018 Harmony XB7
More informationXCKS131 limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13
Characteristics limit switch XCKS - thermoplastic roller lever - 1NC+1NO - snap action - Pg13 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 80.00 USD Main Range
More informationMotor protection relays
Thermal overload relays for currents between 0.09 and 420A Electronic thermal overload relays for currents between 0.4 and A Electronic thermal overload relays with selectable tripping class: 5--20-30
More informationXB4BS542 red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC
Characteristics red Ø40 Emergency switching off pushbutton Ø22 latching turn release 1NC Complementary CAD overall width CAD overall height CAD overall depth Terminals description ISO n 1 Product weight
More informationK1D004ACH cam switch - 4-pole A - for Ø 22 mm
Characteristics cam switch - 4-pole - 45-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing mode Cam
More informationSMS 3xxx/SMS 4xxx Safety switch with separate actuator
Operating Instructions (Translation of the original instructions) SMS 3xxx/SMS 4xxx Safety switch with separate actuator SMS 3xxx SMS 4xxx Wieland Electric GmbH Brennerstraße 10-14 D-96052 Bamberg Tel.
More informationQUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.
PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA
More informationIssued February DATA SHEET 5SX2 MCB. Based on Siemens Industrial Control Catalog
Issued February 2011 DATA SHEET 5SX2 MCB Based on Siemens Industrial Control Catalog General Data Trip characteristics Tripping characteristics acc. to EN 60 898 Tripping characteristic A, -5 Type A characteristic
More informationSIRCO Load break switches for power distribution from 125 to 5000 A
The solution for Load break switches sirco_456_a_1_cat > Main switchboard > Distribution panel > Emergency breaking > Network coupling > Local safety breaking sirco-ac_001_a_1_cat SIRCO 3 x 250 A direct
More informationXCKL115 limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland
Characteristics limit switch XCKL - thermoplastic roller lever - 1NC+1NO - snap - Cable gland Complementary Switch actuation Electrical connection Contacts insulation form Number of steps 1 Positive opening
More informationthe Santon FCS-type switch Disconnect Superior Switch Solutions
the Santon FCS-type switch Disconnect Superior Switch Solutions The technical information given in this table applies to 3 and 4 pole fuse combination switches. FRAME SIZE 1 1 2 3 3 4 4a 4b 5 6 6 nominal
More informationRedundancy unit CP-A RU
2CDC 271 010 F0t06 Features Decoupling of CP power supply units with 2 inputs, each up to 20 A per input / channel Output up to 40 A True redundancy by 100 % decoupling of two parallel connected power
More informationHorizontal distribution busbar HX 3 80/125 A plug-in
87045 LIMOGES Cedex Telephone: +33 5 55 06 87 87 FAX: +33 5 55 06 88 88 Horizontal distribution busbar HX 3 CONTENTS Pages 1. Description... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation -
More informationK1F037MCH cam voltmeter switch - 3L and 3L-N A - for Ø 22 mm
Characteristics cam voltmeter switch - 3L and 3L-N - 60-12 A - for Ø 22 mm Main Range of product Product or component type Component name [Ith] conventional free air thermal current Mounting location Fixing
More informationMonitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064
Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window
More informationXB4BT845 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO
Characteristics Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC+1NO Product availability : Stock - Normally stocked in distribution facility Price* : 101.00 USD Main Range of product Product
More informationXCKN2110P20 limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20
Characteristics limit switch XCKN - metal end plunger - 1NC +1NO - snap - M20 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 20.80 USD Main Range of product OsiSense
More informationSeries Amp Quick Connect Input and Output Power Panels
Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is
More informationZB5FG09 flush mounted selector switch head key pos stay put
Characteristics flush mounted selector switch head key 455 3 pos stay put Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device short name XCKJ Sensor
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More informationPRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5
PRO1250D CT MID DIN rail three phase four wire energy meter. User manual Version 1.5 1 Safety instructions...3 2 Foreword...4 3 CE certificates...5 4 MID certificate...7 5 Performance criteria...8 6 Specifications...8
More informationSeries Amp Pad Mount Quick Connect Input and Output Power Panels
Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.
More informationINSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1
INSTRUCTION MANUAL TRIP CIRCUIT SUPERVISION RELAY GKAD1 TOSHIBA Corporation 2004 All Rights Reserved. ( Ver. 1.6 ) Safety Precautions Before using this product, please read this chapter carefully. This
More informationConveyor Belt Alignment Switches from IDEM
Conveyor Belt Alignment Switches from IDEM Data Sheet Die-Cast Models Python Line Series Stainless Steel Models Using Conveyor Belt Alignment Switches Application: Conveyor Belt Alignment switches are
More informationSingle contact blocks
Single contact blocks Selection diagram CONTACT BLOCKS 10G 01G 10L 01K 1NO leading slow slow 1NO slow lagging slow CONNECTIONS silver contacts (standard) G silver contacts gold plated FIXING V clamping
More informationPHOENIX CONTACT - 08/2009. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Primary-switched power supply for building automation INTERFACE Data sheet 103505_en_02 1 Description PHOENIX CONTACT - 08/2009 Features STEP POWER power supply units for building automation The new STEP
More informationOVERLOAD RELAYS POWER & ACTUATION PROVEN. series
POWER & ACTUATION OVERLOAD RELAYS series Need reliable, accurate overload and phase-loss protection for your motors? c3controls Series Bimetallic Overload Relays provide unmatched protection and can be
More informationXB4BK123B5. Product data sheet Characteristics. Complete illuminated selector switch. position stay put 1NO+1NC 24V. Main.
Characteristics green complete illuminated selector switch Ø22 2- position stay put 1NO+1NC 24V Main Range of product Product or component type Device short name Bezel material Fixing collar material Mounting
More informationControl unit SG-EFS 104/2W. EN Operating instructions. Innovative by tradition. Version SG-EFS 104/2W 24 V=/~
Innovative by tradition. Control unit SG-EFS 104/2W EN Operating instructions Version 0.9 1005196 SG-EFS 104/2W 24 V=/~ Original instructions Mayser GmbH & Co. KG Örlinger Straße 1 3 89073 Ulm GERMANY
More informationXCKJ10541H29 limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20
Characteristics limit switch XCKJ - th.plastic roller lever var. length - 1NC+1NO - snap - M20 Main Range of product OsiSense XC Series name Standard format Product or component type Limit switch Device
More information170 ADM to 60 VDC Module Base / 170 ADO Pt. Relay Out Module Base. Version 1.0
170 ADM 850 10 10 to 60 VDC Module Base / 170 ADO 830 30 6 Pt. Relay Out Module Base Version 1.0 31005197 00 Safety Information NOTICE Read these instructions carefully, and look at the equipment to become
More informationQUICK START GUIDE. vau4/3. Frequency converter. operating instructions /12
operating instructions QUICK START GUIDE Frequency converter vau4/3 28100241101 12/12 1 Safety information Warning of electrical shock! Danger to life! Electrical shock can cause serious injury or even
More informationOperating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x
1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical
More informationSTEP-PS/1AC/24DC/1.75
Primary-switched power supply, 1 AC, output current 1.75 A INTERFACE Data Sheet 103506_en_00 1 Description PHOENIX CONTACT - 05/2008 Features STEP POWER power supply units for building automation The new
More informationMULTI-POLE PHOTOVOLTAIC SYSTEMS. COMPACT and MODULAR Housing
MULTI-POLE Lightning Current and Surge Arresters for PHOTOVOLTAIC SYSTEMS Class I / (B+C) and Class II / (C) COMPACT and MODULAR Housing 44 PV ISPRO BS(R) 12,5 The PV ISPRO BS(R) 12,5 series of over voltage
More informationPM Series Power Meter
PM Series Power Meter Quick Setup Guide - PMC-1000, PMC- 1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See
More informationXCKD3918P16EX limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx
Characteristics limit switch XCKD - roller lever - 2NC + NO - ATEX/IECEx Main Range of product Series name Product or component type Device short name Sensor design Body type Head type Material Fixing
More informationSymmetra PX 160. Maintenance Bypass Enclosure. Installation 05/
Symmetra PX 160 Maintenance Bypass Enclosure Installation 05/2014 www.schneider-electric.com Legal Information The Schneider Electric brand and any registered trademarks of Schneider Electric Industries
More informationSR2B201FU compact smart relay Zelio Logic - 20 I O V AC - clock - display
Characteristics compact smart relay Zelio Logic - 20 I O - 100..240 V AC - clock - display Main Range of product Product or component type Complementary Local display Number or control scheme lines Cycle
More informationPGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com/pgr-4700 PGR-4700 MANUAL SENSITIVE GROUND-FAULT RELAY REVISION 2-B-032218 Copyright 2018 by Littelfuse, Inc. All rights reserved.
More informationSITOP power supply. Selectivity modules. Overview. Safety notes. Description, device design, dimension drawing. Mounting/removal 3
Overview Safety notes 1 SITOP power supply Manual Description, device design, dimension drawing 2 Mounting/removal 3 Mounting position, mounting clearances 4 Installation 5 Technical data 6 Safety, approvals,
More informationXB4BT842 Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC
Characteristics Red Ø40 Emergency stop, switching off Ø22 latching push pull 1NC Product availability : Stock - Normally stocked in distribution facility Price* : 79.50 USD Main Range of product Product
More informationSurge Protection Devices Ex9UE2
Surge Protection Devices Ex9UE2 Surge Protection Devices Type 2 (Class II, T2, C) Tested according to EN 61643-11 Maximum continuous operational voltage U c from 275 V up to 440 V AC Versions with 1+0,
More informationThis Datasheet for the IC660BBA104. Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs
This Datasheet for the IC660BBA104 Block 115Vac/125Vdc Analog Current Source 4 Inputs / 2 Outputs http://www.qualitrol.com/shop/p-14425-ic660bba104.aspx Provides the wiring diagrams and installation guidelines
More informationDIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS. Introducing the DIN Series High-quality, high-performance circuit breakers
DIN Series MINIATURE CIRCUIT BREAKERS, RESIDUAL CURRENT CIRCUIT BREAKERS Introducing the DIN Series High-quality, high-performance circuit breakers Features (1) All models fully comply with IEC regulations
More informationSR2A201BD compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display
Characteristics compact smart relay Zelio Logic - 20 I O - 24 V DC - no clock - display Main Range of product Product or component type Complementary Local display Number or control scheme lines Cycle
More informationPGR-3200 MANUAL INSULATION MONITOR
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-3200 MANUAL INSULATION MONITOR REVISION 3-E-040918 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document Number: PM-1025-EN
More informationMechanical Installation Manual SINUMERIK. SINUMERIK 808D Mechanical Installation Manual. Preface. Safety instructions 1. Identification 2.
Preface Safety instructions 1 SINUMERIK SINUMERIK 808D Operating Instructions Identification 2 Mounting 3 Technical data 4 A Appendix Valid for: SINUMERIK 808D Turning (software version: V4.4.2) SINUMERIK
More informationTU531, TU532 Terminal Unit
Ordering Data DATA SHEET TU531, TU532 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 217 200 R0001 1SAP 217 000 R0001 1SAP 417 000 R0001 TU531, terminal unit, 230 VAC,
More informationK1B004TLH cam switch - 1 pole A - screw mounting
Characteristics cam switch - 1 pole - 30-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing mode Cam
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationSDM120 SERIES. SDM120 series User Manual. Single phase two wire DIN rail energy meter (One module)
SDM120 SERIES Single phase two wire DIN rail energy meter (One module) User manual ------------ 1.1 Safety instruction 1.2 Foreword 1.3 Performance criteria 1.4 Specifications 1.5 Basic errors 1.6 Dimension
More informationProtection Equipment
Protection Equipment Price groups 41B, 41E, 41F, 41G, 41H, 41J, 42F, 42J, 143, 401 /2 Introduction Motor starter protectors/ circuit breakers SIRIUS 3RV2 motor starter protectors up to 40 A / General data
More informationXCKN2118G11 limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11
Characteristics limit switch XCKN - thermoplastic roller lever - 1NC+1NO - snap - Pg11 Complementary Tracks Switch actuation Electrical connection Contacts insulation form Positive opening Positive opening
More informationChameleon Stand-alone
Quick Installation Guide Installation and Commissioning Chameleon Stand-alone Power Supply Module, 48 VDC, 650W, HE, IP65 Low Power Outdoor Applications 356849.03 Introduction Warnings..., page 3 Tools
More informationModel 2380 Rack-Mount Kit
Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.tek.com/keithley Model 2380 Rack-Mount Kit Installation Instructions Introduction The Model 2380 Fixed Rack-Mount
More informationResidual Current Devices FRCdM Type B, B+ and Bfq Digital
Residual Current Devices FRCdM Type B, B+ and Bfq Digital All-current sensitive RCCB for fault or additional protection Digital Features System Monitoring: Preventive information / warning before the RCD
More informationPRO1 V21.xxx series MID DIN rail single phase two wire energy meter
PRO1 V21.xxx series MID DIN rail single phase two wire energy meter PRO1D V21.212 Version 1.1 Note: the picture on the frontpage is a meter from the series of this meter, it might not be exactly the same
More informationK1D012ULH cam changeover switch - 2-pole A - screw mounting
Characteristics cam changeover switch - 2-pole - 90-12 A - screw mounting Main Range of product Product or component type Component name [Ith] conventional free air thermal current Product mounting Fixing
More informationOvervoltage Protection Devices
Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12
More informationThis Datasheet for the IC660BBA026. Block 24/48Vdc Analog Current Source 6 Inputs.
This Datasheet for the IC660BBA026 Block 24/48Vdc Analog Current Source 6 Inputs http://www.cimtecautomation.com/parts/p-14421-ic660bba026.aspx Provides the wiring diagrams and installation guidelines
More informationAllen-Bradley 1492-RCDA4A40
Dual terminals provide wiring/bus bar flexibility and clamp from both sides to improve connection reliability Suitable for DIN Rail mounting Approval marks are easily visible on dome Terminal design helps
More informationSafety switches for hinged doors
C Safety switches for hinged doors Selection diagram FR FM FX FZ FK 18 7 9 snap action overlapped CONTACT BLOCKS 21 NC 1NO+ CONDUIT ENTRIES Threaded conduit entries (standard) With cable gland assembled
More informationPCT2000. User Manual. Precision current transducer 2000 A
PCT2000 User Manual PCT2000 Precision current transducer 2000 A User Manual Status: November 6, 2018 Copyright 2018 ZES ZIMMER Electronic Systems GmbH Pfeiffstraße 12 61440 Oberursel (Taunus), Germany
More informationXCKN2106P20 limit switch XCKN - cat's whisker - 1NC+1NO - snap - M20
Characteristics limit switch XCKN - cat's whisker - 1NC+1NO - snap - M20 Product availability : Non-Stock - Not normally stocked in distribution facility Price* : 28.80 USD Main Range of product OsiSense
More informationUser s Manual. ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual
User s Manual ACS550-PD Stock 3R Irrigation Packaged Drive Supplement to ACS550-U1 User s Manual 2 ACS550-PD 3R Irrigation Packaged Drive ACS550 Drive Manuals GENERAL MANUALS ACS550-U1 User s Manual (1
More information