Premset kv Compact modular vacuum switchgear with Shielded Solid Insulation System Catalog. Medium Voltage Distribution

Size: px
Start display at page:

Download "Premset kv Compact modular vacuum switchgear with Shielded Solid Insulation System Catalog. Medium Voltage Distribution"

Transcription

1 2017 Catalog Premset 17.5 kv Compact modular vacuum switchgear with Shielded Solid Insulation System Medium Voltage Distribution schneider-electric.com/premset

2

3 General Contents Overview 10 Building your solution 26 General characteristics 38 Core units 46 Protection, monitoring and control 88 Connections 118 Technical appendix 130 schneider-electric.com Premset Catalog 3

4 The new generation of Medium Voltage Switchgear PM Safety A concentrate of innovation dedicated to customer safety Reliability A long-lasting performance securing customer service continuity Efficiency A smart solution entirely designed to optimize customer assets Flexibility A compact and modular design for all customer application 4 Premset Catalog schneider-electric.com

5 Safety A concentrate of innovation dedicated to customer safety Simple and user-friendly operation The Premset 3-in-1 system has proven itself to be one of the most reliable and end-user friendly MV switchgear system, providing: Earthing in a single operation Intuitive mimic diagram and operation Direct downstream earthing Positively driven built-in interlocks Easy front access to cable test injection points PM PM Closed position scheme Open and disconnected Earthed Peace of mind and safety through the SSIS technology Extending protection to the entire switchgear assembly Premset switchgear is the first global product to offer shielded solid insulation throughout. Therefore it extends equipment service life, resulting in a lower total cost of ownership (TCO). With no part of the main circuit exposed to free air and shielded by earthed screen, the system is accidentally touchable and significantly reduces the risk of internal arc. The system is applicable for all network functions, including: Load break switches or circuit breaker Integrated metering units current and voltage transformers High safety for the operator during cable testing and diagnosis This integrated cable test feature, implemented by dedicated earthed rods, accessible from the front, without needing to enter the cable box, operate the main switches or dismantle cable terminations. This device meets IEC standard requirements. schneider-electric.com Premset Catalog 5

6 Efficiency A smart solution entirely designed to optimize customer assets PE90822_1 The efficiency you deserve, optimal, maximum Because the range uses the same design for every configuration, customizing your switchgears is easier than ever before. And with standardized dimensions, reduced footprint, and simple front power connections, time and money spent installing Premset is greatly reduced. Every aspect of the system is designed with the intention of making installation and adaptations as seamless as possible, including: Straightforward assembly with identical busbar and cable connections for the entire range Easy-to-install patented universal flat power connection system Easy cabling since all cable connections are at a height of 700 mm Associating an innovative maintenance program for your total peace of mind Intelligent, Smart grid-ready solutions To enhance your electrical distribution networks through advanced monitoring and control, Premset architecture is designed with such features as: Feeder automation, with switchgear including built-in communication and local intelligence Load management, with integrated smart metering Asset management, with advanced switchgear and transformer monitoring Automatic Transfer System, with integrated source transfer solution to reduce power supply interruption 6 Premset Catalog schneider-electric.com

7 Architecture with distributed intelligence The intelligent electronic devices (IEDs) used in Premset solutions allow easy integration, based on a standard communications protocol, with a plug-and-play scanning system for easy configuration. All this adds up to a flexible system with integrated Web technology, pre-engineered and pre-tested, which you can easily upgrade as necessary. With Premset architecture, you can easily build a smarter MV distribution system. PM Communication Network Radio / GSM / GPRS / Ethernet Intelligent Electronic Devices Fault detection Protection Measurement Local control Remote control schneider-electric.com Premset Catalog 7

8 Reliability A long-lasting performance securing customer service continuity PM PM Few minutes to choose it, a life time to enjoy it Extending protection to the entire switchgear assembly, Premset is the first global product to offer shielded solid insulation throughout, enhancing long-term peace of mind. The system is applicable for all network functions, including: Load break switches or circuit breakers Integrated metering units Current and voltage transformers Intuitive operation reduces worker risk With only two operations from line to earth one to open and disconnect, and one to earth the Premset range optimises operating safety, keeping all aspects as simple as possible. Additionally, standard built-in interlocking between the main and earthing functions is keyless and positively driven, making every interaction with the unit as safe and easy as possible. Faithfull on long term End-of-life management is easier, because SF6-free design eliminates worries about future regulations. Shielded Solid Insulation System (SSIS) SSIS is applicable for any function such as load break switches or circuit breakers, SSIS compact metering functions, or current and voltage transformers 8 Premset Catalog schneider-electric.com

9 Flexibility A compact and modular design for all customer application From easy customisation to very specific needs Whether you choice will be for ready-to-buy, easy configuration and design, with short delivery time, or whether you need a tailoredmade solution to suit your specific requirements, Premset offers the answer your are expecting. Premset range proffers a large choice of functions to meet any kind of application: switches, circuit breakers, metering functions, to adapt any substation room and cabling - simple and easy operating. PM All-in-one solution A unique connection interface for all elements, result of a patented design from Schneider-electric: one set of three connections for cables, that can be used in various directions (front, rear, bottom, top) Embedded voltage and current sensors, optimising protection and control, with integrated CT, VT around core function: no need for extra nor larger cubicle A universal flat power connection system, ensuring earth shield continuity (Schneider Electric patented design) A large choice of cable box dimensions, to adapt any substation room and cabling, with option of embedded voltage Premset - by Schneider Electric: The greatest innovation in Medium Voltage Switchgear in the last 10 years schneider-electric.com Premset Catalog 9

10 Overview 10 Premset Catalog schneider-electric.com

11 Overview Presentation 12 Architecture and components 15 Distributed intelligence 20 schneider-electric.com Premset Catalog 11

12 Overview Presentation PM PM Shielded Solid Insulation System Breaking and disconnection Earthing switch Shielded Solid Insulation System The entire main circuit is solid insulated with epoxy or EPDM, eliminating all live parts in free air: Insensitive to harsh environments (humidity, dust, pollution) Drastic reduction of risk of phase-to-phase faults The solid insulation is shielded, i.e. its surface is at earth potential everywhere (no electrical field in free air): System is accidentally touchable, in accordance with PA class of IEC Extended life expectancy All functions with shielded solid insulation have a longer life expectancy, including the M06S compact metering unit. Innovative single line diagram, new arrangement of main functions The Premset single line diagram is composed of: Switch-disconnector using vacuum interrupters Earthing switch within sealed tank with air at atmospheric pressure MV cables can be directly earthed, via earthing switch, without the contribution of any other device The arrangement of two devices in series provides double isolation between busbars and cables The system does not contain SF6 and is RoHS and REACH compliant, for your total peace of mind regarding end of life treatment and environmental concerns. 3 in 1 integrated core units All the necessary functions: breaking, disconnection and earthing, are embedded in a single device: PM Operation of earthing switch Simple operation, with just 3 positions for all units: connected opened & disconnected earthed Intuitive mimic diagram, with two clear and reliable indicators (in accordance with IEC ) All interlocks between functions are built-in as standard, positively driven and Operation of main switch without keys. This applies to all types of circuit breakers and load-break switches. 12 Premset Catalog schneider-electric.com

13 Overview Presentation Consistent range of switches and circuit breakers to suit any application The range of core units is composed of 3 switches and 5 circuit breakers: I06T: simple load-break switch for cable incomers or feeders I06H / I12H: heavy duty switch for transfer between multiple sources D01N and D02N: fast clearing circuit breakers for fuseless MV/LV transformer overcurrent protection D06N: simple circuit breaker for general protection D06H / D12H: O-CO-CO heavy duty circuit breaker with fast reclosing capacity for line protection. Modular system architecture, simplifying installation and upgrading The entire range of core units is optimized for dedicated applications, sharing: Same dimensions and footprint, 375 mm width in particular Same auxiliaries such as electrical operation devices, accessories and options Same easy operation and possibility of installation against a wall Extensive cable entry possibilities including bottom-front, bottom-rear, top-rear Same cable connections with type C (type "C" from EN 50181), 700 mm above floor Also it is applicable as well to other units, such as: Compact metering M06S and M12S with shielded solid insulation Bus riser G06 and G12 Voltage metering or Power supplier VTM, VTP, VTM-D, VTP-D schneider-electric.com Premset Catalog 13

14 Overview Presentation Innovative auxiliary feature (optional) Live cable interlock Electrical interlock helps to avoid the earthing of live cables. Cable test device, interlocked with earthing switch, simplifying cable testing and diagnosis: Cable testing without accessing cable box or dismantling cable connections Test device connection from the front of the switchboard, while cables remain earthed Reliable interlocks with earthed star point Circuit breaker testing with dedicated device for primary injection Primary test current injection without disconnectiong CTs or modifying relay setting Source changeover controller devices Ready for smart grids D06H heavy duty circuit breaker: Dedicated to line management (with fast reclosing capacity and O-CO-CO cycle) Very small footprint (375 mm width) Built-in self-powered protection, embedding communication Integrated metering and power measurement functions Compact metering unit with 375 mm width and shielded solid insulation Integration of power measurement in incomers or feeders without additional space Feeder automation features: Modular architecture for scalable solutions (distributed intelligence) Linked by field bus using standard RJ45 Modbus protocol Easy to integrate in SCADA systems via multiple protocols (IEC 61850) Embedded web interface PM m 14 Premset Catalog schneider-electric.com

15 Overview Architecture and components Premset switchboards are made up of functional units, each representing a typetested assembly composed of a basic core unit and other functional blocks designed to work together in any combination. The core units are optimized for each typical application and the assembly for ms a totally insulated functional unit insensitive to the environment. This Premset medium voltage system makes it possible to meet most of your application needs. Flexibility and simplicity in the design of functional units for any application Safety and reliability of type-test assemblies Space savings Freedom from environmental constraints Shorter delivery and the possibility of making last minute modifications Easy extension and upgrades Functional unit = An assembly of functional blocks LV cabinet Protection relay Measurement Control Switchboard Functional unit Cable test DM = + Core unit Switch Circuit breaker Metering unit Riser unit Top connections Busbars Cables Bottom connections Cables Bars PM Bottom compartment Cable box Reduced height Extra plinth schneider-electric.com Premset Catalog 15

16 Overview Architecture and components Unsurpassed simplicity with mix-and-match modular architecture based on functional blocks. Low Voltage cabinet Different heights Top connections PM Cable test Internal arc gas exhaust duct Core unit Different types Bottom connections Sensors CTs and VTs Sensors CTs and VTs Cable compartment Different heights and depths 16 Premset Catalog schneider-electric.com

17 Overview Architecture and components A big step for safety and reliability with SSIS Shielded Solid Insulation System. Modular busbar system with shielded solid insulation PM Vacuum bottles with shielded solid insulation for breaking and disconnection Integrated air-insulated line earthing switch enclosed in tank with shielded solid insulation Built-in current sensors for optimised protection and control, available in versions with shielded solid insulation where required Front aligned cable connections with shielded solid insulation, designed for easy clamping schneider-electric.com Premset Catalog 17

18 Overview Architecture and components Current and voltage transformers integrated in main functions. Front bottom connection Current transformers located around bushings Measurement current transformer for power measurement (ARU1) Measurement current transformer for fault passage indication or Ammeter (CTR2200) PM Protection current transformer or sensors located under the core unit Dedicated current transformer (CuA, CuB) for VIP integrated self-powered protection Low power current transformer (TLPU1) for Sepam 1 A ring-type current transformer (ARU2) for Sepam, MiCOM, Easergy range, or any conventional relay Internal arc gas exhaust duct Upwards exhaust or downwards exhaust Voltage transformers located behind the cables Phase-to-earth voltage transformers (VRU1) Current transformers located around cables Ring-type current transformer for power metering or protection (ARC6) Earth fault toroidal current transformer for high sensitivity earth fault protection (CSH120/200) Measurement current transformer for fault passage indication or Ammeter (MF1) 18 Premset Catalog schneider-electric.com

19 Overview Architecture and components Flexible cable connection easy substation arrangement to meet all the applications. Rear top connection PM Evacuation duct conduit Internal arc gas upwards exhaust Rear bottom connection PM Internal arc gas exhaust duct Upwards exhaust or downwards exhaust schneider-electric.com Premset Catalog 19

20 Overview Distributed intelligence Premset is Web-enabled to let you access information on your electrical installation via a PC with a standard Web browser. With Premset, intelligence can be added to functional units by integrating protection, control and monitoring IEDs (Intelligent Electrical Devices). The IEDs have dedicated locations and cabling and are daisy-chained throughout the various functional units using RJ45 connectors and Modbus protocol. A gateway can be used to connect the IEDs to supervision systems via Ethernet, TCP-IP and/or radio-frequency communication. Radio GSM GPRS R200 PM Communication Network Radio / GSM / GPRS / Ethernet Protection Power Meter / Quality Network control & monitoring PM Sensors 20 Premset Catalog schneider-electric.com

21 Overview Distributed intelligence DM Energy costs Premset switchboards are designed to integrate distributed intelligence for feeder automation, protection and energy quality applications. Power quality Continuity of service Energy quality applications LOCAL CONTROL Motor control: SC110 Control panel: SC-MI20 SC-MI20 PROTECTION RELAYS Self-powered: VIP 40 and VIP 45, VIP 400 and VIP 410 Auxiliary powered: Sepam, MiCOM and Easergy ranges REMOTE CONTROL Embedded intelligent devices Switch controller for remote communication network : SC110????????? VIP 410 Sepam Remote communication network (GSM /GPRS / Ethernet/Radio): R200 Automatic Transfer System: ATS100 Backup power supply: PS100 MiCOM Easergy P5 PS100 R200 MEASUREMENT Ammeter: AMP21D Power Meter: PM5000 Power/Quality Meter: PM8000 FAULT DETECTION Fault Passage Indicators: Flair 21D/22D, Flair 23DM Voltage indicators: VPIS, VDS Voltage relay: VD23 SC110A ATS100 PM8000 Flair 23DM schneider-electric.com Premset Catalog 21

22 Overview Distributed intelligence DM IP Communication network Distributed architecture for easy installation, operation and scalability The IEDs (Intelligent Electrical Devices) used in the Premset system have been designed to optimise substation performance and compactness. They can be used to build a robust distributed architecture suited to harsh environments. Modular architecture for scalable solutions from local control up to complex feeder automation, optimising cost and performance by letting you choose only what you need Each IED is fully integrated in a functional unit with a dedicated location and cabling Pre-engineered, pre-tested and cost effective, the system includes the necessary sensors, switchgear interfaces, power supplies, communication solutions and HMIs Easy integration based on field bus communication between IEDs with a plug and play system that scans and configures the system The field bus uses standard RJ45 Modbus protocol open to third-part devices Each IED has a compatible XML description file based on CIM (Common Information Model) / IEC standard. This allows easy configuration to communicate with any RTU (Remote Teminal Unit) or SCADA (Supervisory Control And Data Acquisition) system. PE58300 Ready for smart grids In the 80s and 90s, RTUs (Remote Terminal Units) were mainly used in feeder automation applications to improve energy availability and reduce the number and duration of outages. Today RTUs have evolved to integrate functions such as automatic meter reading and load management. Ready for the future, the Premset system R200 RTU has downloadable firmware to keep pace with these and other evolving possibilities of smart grids. Web technology Premset integrates Web technologies so that access to information on your electrical installation is as easy as opening a Web page. All you need is a standard Web browser and a PC connected via: Your local area network A pluggable connection to the Premset switchboard A mobile network access (3G, 4G, GPRS). 22 Premset Catalog schneider-electric.com

23 Overview Distributed intelligence PM VIP self-powered protection relay For higher MV network availability VIP relays are self-powered while Sepam relays require an auxiliary power supply. Self-powered protection relays increase the availability of the MV network and are suited to most applications. VIP 400/410 Insensitive to voltage drop due to faults Not dependent on UPS systems Less dependent on the external environment (EMC, LV overvoltages) because they require no external connections. In addition, the VIP 410 offers enhanced sensitivity to low earth-fault currents and provides additional diagnostics with time-stamped logs thanks to a dual power supply and a communication port. PM Circuit breaker For improved MV/LV transformer protection With the VIP 40/45, Premset circuit breakers provide MV/LV transformers superior protection compared to traditional MV switch-fuse solutions - at an equivalent lifetime cost. The main advantages are: VIP 40/45 Better discrimination with other MV and LV protection devices Improved protection performance for inrush current, overloads, low magnitude phase-faults and earth-faults Greater harsh climate withstand. Fast clearing time, to limit the consequences of internal arcing in the transformer. EMS58355 Auto-adapting Fault Passage Indicator With remote communication for higher power network availability The Flair range offers cost-effective auto-adapting fault passage indicators (FPI) that can be fully integrated in the cubicle. Flair FPI In addition to the Flair 21D /22D self-powered FPIs, the range includes the Flair 23DM, a powerful IED with a communication port. The Flair 23DM is linked to the voltage presence indication system (VPIS) to confirm faults by undervoltage instead of current measurement, thereby avoiding transient faults The Flair 23DM provides an integrated output voltage relay for automatic transfer switch (ATS100) or other applications Phase fault and standard earth fault detection are maintained even if the power supply is lost. The auxiliary power supply is only needed for communication and the voltage presence relay The communication port provides the current values, records diagnostic information (voltage drops, transient fault indications) and makes it possible to modify settings remotely. schneider-electric.com Premset Catalog 23

24 Overview Distributed intelligence PE88030 Full range of protection relays Schneider Electric is a trusted, global provider of protection relays and control solutions as well as a leader in electical distribution innovation. Our ranges of protection relays represents the outcome of more than 100 years of manufacturing and power system experience. PM PM Sepam range MiCOM range Sepam range Sepam series digital protection relays take full advantage of Schneider Electric s experience in electrical network protection to meet your needs needs with effective protection of life and property. MiCOM range MiCOM protection provides the user with a choice of cost-optimized solutions for specific protection requirements within the distribution network. The MiCOM relay series offers comprehensive protective function solutions for all power supply systems, as well as for various functional and hardware project. Easergy P5: a fusion of new ideas and proven expertise Easergy P5 combines fresh thinking on modern electrical challenges with a strong heritage from two popular protection relay ranges: Sepam and MiCOM. Easergy P5 s modern, digital features provide a unique combination of services designed to boost operational efficiency and safety for the user. Easergy P5 Product selection, configuration, and ordering have been made easy with the latest online tools. The asset database provides a management platform, which stores and organizes all information securely and is quickly accessible. Easergy SmartApp provides simple access to key functions and settings for nonexpert users and enables quick access to all information and documentation. PM Easergy 10 years Warranty Simplify your Easergy P5 daily operation via the Easergy P5 SmartApp! Easergy P5 provides access to an extended warranty program when users register their product using the QR code and follow a simple process with the myschneider mobile app. 24 Premset Catalog schneider-electric.com

25 Overview Distributed intelligence Backup power supply PM Backup power supplies (UPSs or batteries) are now common in industrial and commercial premises. However, they often represent a weak link in the power supply chain and their failure can have serious consequences. Given the harsh environment and critical nature of substations, the Premset system includes the PS100, a dedicated solution with a high insulation level designed to provide 24 hours of backup power to electronic devices. PS100 Maintenance is easy with: Just one battery to replace End-of-life alarm possible via Modbus communication PE57570p DM Easergy R200 and ATS100 The power and experience of Easergy FRTUs embedded in Cubicles for cost effective remote control and monitoring of MV substations: R200 ATS100 Easergy R200 is a Remote Terminal Unit (RTU) that integrates all the functions for remote supervision and control of an MV switchboard cubicle. The ATS100 drives automatic transfer from the normal MV source to the backup source in order to keep supplying the MV substation in case of failure of the normal source. ATS100 can drive either Load Break Switch or Circuit Breaker. PM Easergy TH110 wireless thermal sensor * The power connections in the Medium Voltage products are one of the most critical points of the substations. Loose and faulty connections cause an increase of resistance in localized points that will lead to thermal runaway until the complete failure of the connections TH110 Easergy TH110 is part of the new generation of wireless smart sensors ensuring the continuous thermal monitoring of all the critical connections made on field allowing to: Prevent unscheduled downtimes Increase operators and equipments safety Optimize maintenance with predictive information * Please consult us for availability schneider-electric.com Premset Catalog 25

26 Building your solution 26 Premset Catalog schneider-electric.com

27 Building your solution Main applications 29 Incomer and feeder functions 32 Transformer protection functions 33 Bus section functions 34 Bus riser functions 35 Metering & measurement functions 36 Special functions 36 schneider-electric.com Premset Catalog 27

28 Premset all-in-one Best-in-class switchgear First-class terminal Download the free application, now available for ios

29 Building your solution Main applications PM PE5813 PM Why Premset? Premset switchboards are modular, compact, smart, with optimized safety and insensitivity to harsh environments. For these reasons, they offer very high reliability and efficiency for a wide range of applications. Typical applications Premset applications can be found in all Medium Voltage secondary distribution substations. Buildings and industry MV/MV consumer substation direct connection MV/LV consumer substation double feeder MV/LV consumer substation loop connection MV/LV consumer substation radial connection MV/LV consumer substation with MV backup MV private network MV/LV substation. Distribution networks MV/MV switching substation MV/LV distribution substation MV/LV Ring Main Unit MV distributed generation. Premset advanced communication possibilities open the way to applications such as: Local control up to complex feeder automation MV Automatic Transfer System (ATS) RTU with new Smart Grid functions for load management. PM PM schneider-electric.com Premset Catalog 29

30 Building your solution Main applications Distribution network selection chart Energy & infrastructure DM100032EN HV/MV MV/MV switching substation Distributed generation G G M MV/LV distribution substation MV/LV distribution substation (Ring Main Unit) Line incomer or Line feeder Generator incomer Line protection Transformer protection General protection Bus section Bus riser 30 Premset Catalog schneider-electric.com

31 Building your solution Main applications Buildings & Industry selection chart Buildings HV/MV Industry Datacentres & networks M MV/MV consumer substation direct connection M MV/LV consumer substation double feeder M MV/LV consumer substation loop connection MV private network M MV/LV substation MV/LV consumer substation radial connection M MV/LV consumer substation with MV backup M G G schneider-electric.com Premset Catalog 31

32 Building your solution Incomer and feeder functions Function Line incomer/ Line feeder Core unit type l06t I06H I12H D06N D06H Typical application of protection Line incomer or line feeder General protection Line protection Core unit Disconnecting switch with lever-operated CIT mechanism and integrated earthing switch Disconnecting switch with stored-energy OCO mechanism and integrated earthing switch Disconnecting switch with stored-energy OCO mechanism and integrated earthing switch Disconnecting circuit breaker with latching CI1 mechanism and integrated earthing switch Generator protect. Disconnecting circuit breaker with stored-energy OCO mechanism and integrated earthing switch Dimension: width (mm) Single-line diagram See details Page Earthing switch 71 Cable testing device 124 Live cable interlock 105 Protection * VIP 40/45 Self-powered 93 VIP 400 Self-powered 95 VIP 410 Dual powered 95 Easergy P5 Auxiliary powered 98 Sepam Auxiliary powered 98 MiCOM Auxiliary powered 98 FPI (2) - Flair 21/22D/23DM * 100 Integrated measurement * AMP21D Ammeter 107 PM5000 Power Meter 108 PM8000 Power/Quality Meter 109 Control Electrical operation 110 Additional opening coil (MX or MN) 75 Auxiliary contacts 76 Voltage indication * VPIS or VDS Voltage indication 103 p p p p p VD23 Voltage relay 104 Metering current transformers * ARU1 Ring CTs 81 ARC6 Ring CTs 82 ARC5 Ring CTs 82 ARM3 / AD12 Block CTs 84 ARPJ3 / AD13 Block CTs 84 Metering voltage transformers * VRU1 Screened VTs 83 VDF11/VDF21 DIN VTs 86 VRQ2 Block VTs 87 VRU2 Auxiliary power 83 VDC11/VDC21 DIN VTs 86 VRC2 Block VTs 87 VT protection - Fuses * Only one option possible Standard offer Option (1) Optional possible only wih VIP relay (2) FPI: Fault Passage Indicator Phaseto-earth Phaseto-phase (1) (1) 32 Premset Catalog schneider-electric.com

33 Building your solution Incomer & feeder / Transformer protection functions Line incomer/ Line feeder Transformer protection D12H G06 M06S M06A M12A D01N D02N Line protection Line incomer or line feeder Transformer protection Generator protect. Disconnecting circuit breaker with stored-energy OCO mechanism and integrated earthing switch Direct connection to busbars Solid-insulated earth-screened metering unit Air-insulated metering unit Air-insulated metering unit Disconnecting circuit breaker with latching CI1 mechanism and integrated earthing switch Disconnecting circuit breaker with latching CI1 mechanism and integrated earthing switch (1) (1) schneider-electric.com Premset Catalog 33

34 Building your solution Bus section functions Function Bus section Core unit type l06t I06H I12H D06N D06H D12H Typical application of protection Bus section Core unit Disconnecting switch with lever-operated CIT mechanism and integrated earthing switch Disconnecting switch with stored-energy OCO mechanism and integrated earthing switch Disconnecting switch with stored-energy OCO mechanism and integrated earthing switch Disconnecting circuit breaker with latching CI1 mechanism and integrated earthing switch Disconnecting CB with stored-energy OCO mechanism and integrated earthing switch Disconnecting CB with stored-energy OCO mechanism and integrated earthing switch Dimension: width (mm) Single-line diagram See details Page Earthing switch 71 Cable testing device 124 Live cable interlock 105 Protection * VIP 40/45 Self-powered 93 VIP 400 Self-powered 95 VIP 410 Dual powered 95 Easergy P5 Auxiliary powered 98 Sepam Auxiliary powered 98 MiCOM Auxiliary powered 98 FPI (2) - Flair 21/22D/23DM * 100 Integrated measurement * AMP21D Ammeter 107 PM5000 Power Meter 108 PM8000 Power/Quality Meter 109 Control Electrical operation 110 Controller and accessories Additional opening coil (MX or MN) 75 (1) (1) Auxiliary contacts 76 Voltage indication * VPIS or VDS Voltage indication 103 VD23 Voltage relay 104 Metering current transformers * ARU1 Ring CTs 81 ARC6 Ring CTs 82 ARC5 Ring CTs 82 ARM3 / AD12 Block CTs 84 ARPJ3 / AD13 Block CTs 84 Metering voltage transformers * VRU1 Screened VTs 83 VDF11/VDF21 DIN VTs 86 VRQ2 Block VTs 87 VRU2 Auxiliary power 83 VDC11/VDC21 DIN VTs 86 VRC2 Block VTs 87 VT protection - Fuses * Only one option possible Standard offer Option (1) Optional possible only wih VIP relay (2) FPI: Fault Passage Indicator Phaseto-earth Phaseto-phase 34 Premset Catalog schneider-electric.com

35 Building your solution Bus riser + Metering & measurement functions Bus riser Metering & measurement G12 G06 M06S M12S M06A M12A M06A M12A Bus riser Metering & measurement SSIS bus riser SSIS bus riser SSIS metering unit SSIS metering unit Air-insulated metering unit Air-insulated metering unit Air-insulated metering unit Air-insulated metering unit schneider-electric.com Premset Catalog 35

36 Building your solution Metering & measurement functions + Special functions Function Metering & measurement Special functions Core unit type VTM VTM-D VTP VTP-D Typical application of protection Metering & measurement Special functions Core unit Metering voltage transformer: three SSIS (2) phase-toearth VTs Metering voltage transformer: three SSIS (2) phase-to-earth VTs, with D01N circuit-breaker Auxiliary power supply, voltage transformer: one SSIS phase-to-phase VT Auxiliary power supply, voltage transformer: one SSIS phase-to-phase VT, with D01N circuit breaker protection Dimension: width (mm) Single-line diagram See details Page Earthing switch 71 Cable testing device 124 Live cable interlock 105 Protection * VIP 40/45 Self-powered 93 VIP 400 Self-powered 95 VIP 410 Dual powered 95 Easergy P5 Auxiliary powered 98 Sepam Auxiliary powered 98 MiCOM Auxiliary powered 98 FPI (3) - Flair 21/22D/23DM * 100 Integrated measurement * AMP21D Ammeter 107 PM5000 Power Meter 108 PM8000 Power/Quality Meter 109 Control Electrical operation 110 Controller and accessories Additional opening coil (MX or MN) 75 Auxiliary contacts 76 Voltage indication * VPIS or VDS Voltage indication 103 VD23 Voltage relay 104 Metering current transformers * ARU1 Ring CTs 81 ARC6 Ring CTs 82 ARC5 Ring CTs 82 ARM3 / AD12 Block CTs 84 ARPJ3 / AD13 Block CTs 84 Metering voltage transformers * VRU1 Screened VTs 83 VDF11/VDF21 DIN VTs 86 VRQ2 Block VTs 87 VRU2 Auxiliary power 83 VDC11/VDC21 DIN VTs 86 VRC2 Block VTs 87 VT protection - Fuses * Only one option possible Standard offer Option (1) Optional possible only wih VIP relay (2) Shielded Solid Insulation System (3) FPI: Fault Passage Indicator Phaseto-earth Phaseto-phase 36 Premset Catalog schneider-electric.com

37 Building your solution Special functions Special functions ES-B Special functions Dedicated to busbar earthing I06T cable in/out Disconnecting switch with lever-operated CIT mechanism and integrated earthing switch I06H cable in/out Disconnecting switch with stored-energy OCO mechanism and integrated earthing switch D01/02/06N cable in/out Disconnecting circuit breaker with latching CI1 mechanism and integrated earthing switch D06H cable in/out Disconnecting circuit breaker with stored-energy OCO mechanism and integrated earthing switch (1) (1) schneider-electric.com Premset Catalog 37

38 General characteristics 38 Premset Catalog schneider-electric.com

39 General characteristics Characteristics 40 Standards 41 Internal arc fault withstand 42 Operating conditions 44 schneider-electric.com Premset Catalog 39

40 General characteristics Characteristics Main electrical characteristics Voltage Rated voltage kv Rated frequence Hz 50/60 Insulation level Rated short-duration power-frequence withstand voltage - phase to phase, phase to earth, open contact gap across the isolating distance Rated lightning impulse withstand voltage - phase to phase, phase to earth, open contact gap (1) 95 - across the isolating distance (1) 110 Current Rated normal current for the busbar up to A 1250 Rated short-time withstand current for switchgear with tk=1 s up to ka 25 for switchgear with tk=3 s up to ka 25 for switchgear with tk=4 s up to ka 20 Rated short-circuit breaking current Isc Circuit breaker: D01N, D02N,D06N, D06H, D12H up to ka 25 Internal arc withstand A-FLR ka/1s 21 A-FLR ka/1s 25 (2) (1) Higher values of the rated lightning impulse withstand voltage available with -95 kv for phase-to-phase, phase-to-earth, open contact gap as well as -110 kv across the isolating distance (2) except M06A, M12A (3) LSC1 for bus riser and metering functions PM mm to 2195 mm 500 mm or 700 mm front or rear cabling Dimensions Uniform dimensions for the entire system Width: 375 mm for all 630 A switch, circuit breaker and metering units with shielded solid insulation 1250 A switch, circuit breaker and air insulation metering units: 750 mm wide, but still fully compatible with the rest of the system Depth: 910 mm (1135mm for cable front connection with arc control design, 1208 mm for cable rear connection with arc control design) Cable connections: 700 mm high front-aligned connections (500 mm with lowheight bottom compartment) Height: 1350 to 2195 mm, depending on LV cabinet (can be reduced to a minimum of 1350 mm with low-height bottom compartment 910 or 1135 mm or 1208mm 375 mm 40 Premset Catalog schneider-electric.com

41 General characteristics Standards IEC standards Premset units meet all the following recommendations, and standards: IEC : High voltage switchgear and controlgear - Part 1: Common specifi cations IEC : Part 200: A.C. metal-enclosed switchgear and controlgear for rated voltage above 1 kv and up to and including 52 kv IEC : Part 103: Switches for rated voltages above 1 kv and less than 52 kv IEC : Part 100: High-voltage alternating current circuit breakers IEC : Part 102: High-voltage alternating current disconnectors and earthing switches IEC : Part 206: High-voltage prefabricated switchgear and controlgear assemblies - Voltage presence indicating systems IEC 60529: Degrees of protection provided by enclosures (IP Code) IEC : Instrument transformers - Part 8: Low Power Current Transducers IEC : Instrument transformers Part 2: Current transformers IEC : Instrument transformers Part 3: Voltage transformers IEC 60255: Measuring relays and protection equipment IEC : Part 210: Seismic qualifi cation for metal enclosed switchgear up to 52 kv schneider-electric.com Premset Catalog 41

42 Premset Premset Premset General characteristics Internal arc fault withstand Standard IEC defines internal arc classifi cations to characterise the performance level for protection of persons against effects of internal arcing fault. It also defines the testing procedure and acceptance criteria. The aim of this classifi cation is to show that an operator situated around the switchboard would be protected against the effects of an internal fault. Standard version Qualifi ed for neutral networks with arc extinction coil earthing system The effect of low phase-to-earth internal faults has been type-tested for the standard version of Premset. Premset is IAC qualified for earth fault current of 100 A (IAe). It has successfully passed all the tests in every compartment, in accordance with the latest edition of the IEC standard (edition 2). This demonstrates the ability of standard Premset to withstand internal arcing for tuned (Petersen coil) neutral networks without any specifi c precautions. DM Premset Premset Premset Arc-control version, 21 ka 1 s or 25 ka 1 s (1) class A-FLR (2) Four-sided internal arc protection DM Downwards exhaust Premset Premset Premset The effect of high internal faults, up to 25 ka 1s, has been type-tested on a special version of Premset designed for arc control with two options for gas exhausting (upwards exhaust or downwards exhaust). Premset has successfully passed all the type tests of standard IEC (5 acceptance criteria). The thermal and mechanical forces that an internal arc can produce are absorbed by the enclosure. Operators safety is improved, whatever the installation layout: Access to all four sides when not installed against a wall Front or lateral access when installed against a rear wall Upwards exhaust,gas releases outside room (1) Except M06A, M12A DM Premset Premset Premset (2) IAC (internal arc classifi cation): classifi cation code refers to different types of accessibility according to standard IEC Class A-FLR: A: access restricted to authorised personnel only F: access to the front side L: access to the lateral side R: access to the rear side (3) Please consult us for availability Top exhaust, gas releases inside room (3) 42 Premset Catalog schneider-electric.com

43 General characteristics Internal arc fault withstand Drastically reduced risk of internal arc fault Premset shielded solid insulation technology provides phase-perphase insulation and screening, and thereby make phase-to-phase fault impossible by design : this have been proven by tests. For all networks earthed through an impedance, this is of great advantage, as the phase-to-earth fault is limited to a low value, drastically mitigating the effects of the internal arc. Premset arc controlled version has been successfully type-tested in accordance with the edition 2 of the IEC standard, 25kA- 1s, A-FLR. Thus all types of earthing systems are covered, including solidly grounded and isolated ones. Three gas exhausting options Downwards exhaust 21 ka 1s or 25 ka 1s (details information see " Civil engineering, & gas exhaust ": p 140) Upwards exhaust, gas releases outside room 21 ka 1s or 25 ka 1s A-FLR (for installation details, see p 139) Upwards exhaust, gas releases inside room (1) up to 25 ka 1s Installation against a wall For detailed civil engineering information, please refer to page 138. Note: When 500 mm height of cable connection is selected, 16 ka/1 s IAC is max reached. (1) Please consult us for availability schneider-electric.com Premset Catalog 43

44 General characteristics Operating conditions PM100567b Indoor Premset Indoor Premset Partition class and loss of service continuity category Partition class: PM (1) Loss of service continuity category: LSC2 (2) (3) Protection index All external faces of the switchgear: IP3X / IP41 (available as option) / IP32 - IP42 (please consult us for availability) Between compartments: IP2X Main circuit and all HV parts: IP67 (except air insulated metering cubicle: M06A, M12A). Mechanical impact strength IK07 for standard version. Seismic Seismic withstand type test in accordance with standard IEC Flooding Service continuity reached for 96 hours of fl ooding for all MV functions (except air insulated metering M06A, M12A) After fl ooding, accessories, auxiliaries and relays may require maintenance or replacement Environmental characteristics Altitude Up to 3000 m, no particular precautions except screened cable connections Over 3000m, please consult us Temperature (indoor version) Storage : from 40 C to + 80 C Operation: from 25 C to + 40 C (normal conditions) IEC level 3K6 Operation: from +40 C to + 55 C (consult us for special precautions) Condensation / humidity Chemical / pollution Dust IEC 60721: level 3K6 & 3Z7 IEC 60721: level 3C2 IEC 60721: level 3S2 Fire and extinguishability Test at 850 C according to IEC /-11 /-12 UL version Premset Consult us for UL Premset version Outdoor version Consult us for specifi c outdoor IP54 version (1) PM class according to IEC : metallic partitioning between compartments. (2) LSC2 (loss of service continuity) according to IEC : this category offers the possibility of keeping other compartments energised when opening a main compartment. (3) or LSC1 for metering and bus riser functions 44 Premset Catalog schneider-electric.com

45 Notes schneider-electric.com Premset Catalog 45

46 Core units 46 Premset Catalog schneider-electric.com

47 Core units Disconnecting switch 48 I06T - General purpose 48 I06H - Heavy duty 50 I12H - Heavy duty 52 Disconnecting circuit breaker 54 D01N, D02N - MV/LV transformer protection 54 D06N - General protection 56 D06H - Heavy duty line protection 58 D12H- Heavy duty line protection 60 Bus riser 62 G06 - Bus riser 62 G12 - Bus riser 62 Metering 63 M06S - M12S compact metering 63 M06A - M12A Air-insulated metering 64 VTM - Voltage transformer 65 VTM-D - Voltage transformer with circuit-breaker protection 66 Special functions 68 VTP - Auxiliary power supply 68 VTP -D - Auxiliary power supply with circuit-breaker protection 69 ES-B - Busbar earthing switch 71 Cable in/out function 72 Operating mechanism 73 Introduction 73 Accessories 75 Padlocking and keylocking 77 SSIS current and voltage transformers 79 AIS current and voltage transformers 84 schneider-electric.com Premset Catalog 47

48 Core Units Disconnecting switch I06T - General purpose PM The I06T uses vacuum and SSIS technology: Compact solution, only 375 mm width Rated current is 630 A PM Basic equipment 3 in 1 core unit Vacuum disconnecting load-break switch providing both load breaking and disconnection function Earthing switch use air technology in sealed-for-life tank at atmospheric pressure Mechanism Operating load switch with anti-refl ex lever-operated mechanism (CIT type), independent of operator action Operating earthing switch with anti-refl ex lever-operation mechanism, indepent of operator action Full failsafe interlocking between the main switch and earthing switch Three-phase busbars for top connection (630 A) Bottom connection C-type bushing for dry type cable connection or Three phase bottom busbar for bus coupling Voltage presence indicator Cable box Standard built-in padlocking facility With 700 mm length cable connection & 290 mm deep door For main switch, earthing switch and operation selector (shackle diameter <9 mm) Accessories Operation accessory options Connection options DM DM Visibility of earthing contacts Electrical operation Auxiliary contacts on switch and earthing switch Voltage present/absent contact Local/remote control switch Auxiliary power shut down switch Operation counter 1250 A three-phase upper busbars when cable connection Rear cable entry (top or bottom) connection Deeper cable box door (500 mm) Compact cable box with 500 mm length cable connection Enlarged low-voltage cabinet Raising plinth (260 mm or 520 mm) Locking options Key-type interlocking main switch in open-disconnected position (1 or 2 keylocks) earthing switch in cable earthed position (1 or 2 keylocks) earthing switch in line position (1 or 2 keylocks) Interlocking between cable box door and main switch & earthing switch for front cable connection Live cable interlocking 48 Premset Catalog schneider-electric.com

49 Core Units Disconnecting switch I06T - General purpose Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 630 Rated short-time withstand current and duration I k for switchgear with tk=1 s up to ka for switchgear with tk=3 s for switchgear with tk=4 s Rated making capacity of main switch and earhing switches I ma when fr=50 Hz ka peak when fr=60 Hz ka peak No-load mechanical endurance of main switch Electrical endurance of main switch Making capacity endurance of main switch No-load mechanical endurance of earthing switch Making capacity endurance of earthing switch M1 class (IEC ) E3 class (IEC ) E3 class (IEC ) M0 class (IEC ) E2 class (IEC ) Number of operation cycles 1000 Number of operation cycles 100 Number of operation cycles 5 Number of operation cycles 1000 Number of operation cycles 5 schneider-electric.com Premset Catalog 49

50 Core Units Disconnecting switch I06H - Heavy-duty PM The I06H uses vacuum and SSIS technology: Compact solution, only 375 mm width Rated current is 630 A PM Basic equipment 3 in 1 core unit Vacuum disconnecting circuit breaker providing both breaking and disconnection function Three phase bottom busbar for outgoing Mechanism Operating load switch with stored energy type operating mechanism (OCO type) with pushbutton opening and closing and spring charging using a lever Heavy-duty operating cycle (O-0.3 s-co-15 s-co) Anti-refl ex lever-operated mechanism for earthing switch, independent of operator action Full failsafe interlocking between the main switch and earthing switch Three-phase busbars for top connection (630 A) Bottom connection C-type bushing for dry type cable connection or three phase bottom busbar for bus coupling Voltage presence indicator Cable box Standard built-in padlocking facility With 700 mm length cable connection & 290 mm deep door For main switch, earthing switch and operation selector (shackle diameter <9 mm) Accessories Operation accessory options Connection options DM DM100021bis DM Visibility of earthing contacts Electrical operation Auxiliary contacts on switch and earthing switch Voltage present/absent contact Local/remote control switch Auxiliary power shut down switch Operation counter Pushbutton protection cover 1250 A three-phase upper busbars when cable connection Rear cable entry (top or bottom) connection Deeper cable box door (500 mm) Compact cable box with 500 mm length cable connection Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) Locking options Key-type interlocking main switch in open-disconnected position (1 or 2 keylocks) earthing switch in cable earthed position (1 or 2 keylocks) earthing switch in line position (1 or 2 keylocks) Interlocking between cable box door and main switch & earthing switch for front cable connection Live cable interlocking 50 Premset Catalog schneider-electric.com

51 Core Units Disconnecting switch I06H - Heavy-duty Technical characteristics Rated voltage Ur (kv) ,5 Rated current Ir A 630 Rated short-time withstand current and duration Ik for switchgear with tk=1 s up to ka for switchgear with tk=3 s for switchgear with tk=4 s Rated making capacity of main switch and earhing switches Ima when fr=50 Hz ka peak when fr=60 Hz ka peak No-load mechanical endurance of main switch Electrical endurance of main switch Making capacity endurance of main switch No-load mechanical endurance of earthing switch Making capacity endurance of earthing switch M1 class (IEC ) E3 class (IEC ) E3 class (IEC ) M0 class (IEC ) E2 class (IEC ) Number of operation cycles 5000 Number of operation cycles 100 Number of operation cycles 5 Number of operation cycles 1000 Number of operation cycles 5 schneider-electric.com Premset Catalog 51

52 Core Units Disconnecting switch I12H - Heavy-duty The I12H uses vacuum and SSIS technology: Compact solution, only 750 mm width Rated current is 1250 A Basic equipment 3 in 1 core unit Vacuum disconnecting load-break switch providing both load breaking breaking and disconnection function Earthing switch use air technology in sealed-for-life tank at atmospheric pressure PM PM Mechanism Operating load switch with stored energy type operating mechanism (OCO type) with pushbutton opening and closing and spring charging using a lever Heavy-duty operating cycle (O-0.3 s-co-15 s-co) Anti-reflex lever-operated mechanism for earthing switch, independent of operator action Full failsafe interlocking between the main switch and earthing switch Three-phase busbars for top connection (1250 A) Bottom connection C-type bushing for dry type cable connection or Three phase bottom busbar for bus coupling Voltage presence indicator Cable box Standard built-in padlocking facility With 700 mm length cable connection & 290 mm deep door For main switch, earthing switch and operation selector (shackle diameter <9 mm) Accessories Operation accessory options Connection options DM DM100021bis DM Visibility of earthing contacts Electrical operation Auxiliary contacts on switch and earthing switch Voltage present/absent contact Local/remote control switch Rear cable entry (top or bottom) connection Deeper cable box door (450 mm 1250A) Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) Auxiliary power shut down switch Operation counter Pushbutton protection cover Locking options Key-type interlocking main switch in open-disconnected position (1 or 2 keylocks) earthing switch in cable earthed position (1 or 2 keylocks) earthing switch in line position (1 or 2 keylocks) Interlocking between cable box door and main switch & earthing switch for front cable connection Live cable interlocking 52 Premset Catalog schneider-electric.com

53 Core Units Disconnecting switch I12H - Heavy-duty Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 1250 Rated short-time withstand current and duration I k for switchgear with tk=1 s up to ka for switchgear with tk=3 s for switchgear with tk=4 s Rated making capacity of main switch and earhing switches I ma when fr=50 Hz ka peak when fr=60 Hz ka peak No-load mechanical endurance of main switch Electrical endurance of main switch Making capacity endurance of main switch No-load mechanical endurance of earthing switch Making capacity endurance of earthing switch M1 class (IEC ) E3 class (IEC ) E3 class (IEC ) M0 class (IEC ) E2 class (IEC ) Number of operation cycles 5000 Number of operation cycles 100 Number of operation cycles 5 Number of operation cycles 1000 Number of operation cycles 5 schneider-electric.com Premset Catalog 53

54 Core Units Disconnecting circuit breaker D01N, D02N - MV/LV transformer protection The D01N, D02N use vacuum and SSIS technology: The smallest VCB in the world, only 375mm width Rated current is 100 A / 200 A, dedicated design for transformer protection With self power relay optimise performance, fast clearing time of transformer short-circuit < 60s Basic equipment 3 in 1 core unit Vacuum disconnecting circuit breaker providing both breaking and disconnection function Earthing switch use air technology in sealed-for-life tank at atmospheric pressure Mechanism Operating circuit breaker with CI1 type operating mechanism featuring pushbutton opening and antirefl ex lever-operated closing Both operation speed is independent of operator action Full failsafe interlocking between the circuit breaker and earthing switch PM Three-phase busbars for top connection (630 A) Bottom C-type bushing for dry type cable connection connection PM Voltage presence indicator Cable box With 700 mm length cable connection & 290 mm deep door Standard built-in padlocking facility For main switch, earthing switch and operation selector (shackle diameter <9 mm) Accessories Operation accessory options Connection options DM Visibility of earthing contacts Electrical operation Auxiliary contacts on switch and earthing switch Voltage present/absent contact Local/remote control switch Auxiliary power shut down switch Operation counter Additional opening coil (1) Pushbutton protection cover Locking options 1250 A three-phase upper busbars Rear cable entry (top or bottom) connection Deeper cable box door (500 mm) Compact cable box with 500 mm length cable connection Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) Key-type interlocking main switch in open-disconnected position (1 or 2 keylocks) earthing switch in cable earthed position (1 or 2 keylocks) earthing switch in line position (1 or 2 keylocks) Interlocking between cable box door and main switch & earthing switch for front cable connection Live cable interlocking Protection relay and current transformers options Protection relay VIP 45 / 410 Sepam MiCOM Easergy P5 Protection current transformer CuA TLPU1 ARU2 ARC6 Protection voltage transformer VRU1 LPVT (1) only with VIP relay 54 Premset Catalog schneider-electric.com

55 Core Units Disconnecting circuit breaker D01N, D02N - MV/LV transformer protection Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 100 (D01N); 200 (D02N) Rated short-time withstand current and duration I k for switchgear with tk=1 s up to ka for switchgear with tk=3 s for switchgear with tk=4 s Short-circuit breaking capacity I sc up to ka Rated making capacity of main switch and earhing switches I ma when fr=50 Hz ka peak when fr=60 Hz ka peak Capacitive breaking capacity (IEC ) Capacitive breaking class Line charging current 10A, class C2 Cable charging current 25A, class C2 No-load mechanical endurance of circuit breaker Electrical endurance of circuit breaker M1 class (IEC ) E2 class (IEC ) Number of operation cycles ka Operating sequence (when electrical operation on circuit breaker) Maximum number of operation at 100% Isc CO-15s-CO 5 Total clearing time at Isc Fault detection to arc extinguishing ms <60 No-load mechanical endurance of earthing switch Making capacity endurance of earthing switch M0 class (IEC ) E2 class (IEC ) Number of operation cycles 1000 Number of operation cycles 5 schneider-electric.com Premset Catalog 55

56 Core Units Disconnecting circuit breaker D06N - General protection The D06N uses vacuum and SSIS technology: The smallest VCB in the world, only 375mm width Rated current is 630 A With self power relay optimise performance, and it is also open to all of auxilairy power relay Basic equipment 3 in 1 core unit Vacuum disconnecting load-break switch providing both load breaking breaking and disconnection function Earthing switch use air technology in sealed-for-life tank at atmospheric pressure Mechanism CI1 type operating mechanism featuring pushbutton opening and antireflex lever-operated closing Both operation speed is independent of operator action Full failsafe interlocking between the circuit breaker and earthing switch Three-phase busbars for top connection (630 A) PM Bottom connection C-type bushing for dry type cable connection or Three phase bottom busbar for bus coupling Voltage presence indicator PM Cable box Standard built-in padlocking facility With 700 mm length cable connection & 290 mm deep door For main switch, earthing switch and operation selector (shackle diameter <9 mm) Accessories Operation accessory options Visibility of earthing contacts Electrical operation Auxiliary contacts on switch and earthing switch Voltage present/absent contact Local/remote control switch Operation counter Additional opening coil (1) Pushbutton protection cover Connection options 1250A three-phase upper busbars when cable connection Rear cable entry (top or bottom) connection Deeper cable box door (500 mm) Compact cable box with 500 mm length cable connection Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) DM DM100013bis DM Locking options Key-type interlocking main switch in open-disconnected position (1 or 2 keylocks) earthing switch in cable earthed position (1 or 2 keylocks) earthing switch in line position (1 or 2 keylocks) Interlocking between cable box door and main switch & earthing switch for front cable connection Live cable interlocking Protection relay and current transformers options Protection relay VIP 400 / 410 Sepam MiCOM Easergy P5 Protection current transformer CuB TLPU1 ARU2 ARC6 Protection voltage transformer VRU1 LPVT (1) only with VIP relay 56 Premset Catalog schneider-electric.com

57 Core Units Disconnecting circuit breaker D06N - General protection Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 630 Rated short-time withstand current and duration I k for switchgear with tk=1 s up to ka for switchgear with tk=3 s for switchgear with tk=4 s Short-circuit breaking capacity I sc up to ka Rated making capacity of main switch and earhing switches I ma when fr=50 Hz ka peak when fr=60 Hz ka peak Capacitive breaking capacity (IEC ) Capacitive breaking class Line charging current 10A, class C2 Cable charging current 25A, class C2 No-load mechanical endurance of circuit breaker Electrical endurance of circuit breaker M1 class (IEC ) E2 class (IEC ) Number of operation cycles ka Operating sequence (when electrical operation on circuit breaker) Maximum number of operation at 100% Isc CO-15s-CO 30 Total clearing time at Isc Fault detection to arc extinguishing ms <100 No-load mechanical endurance of earthing switch Making capacity endurance of earthing switch M0 class (IEC ) E2 class (IEC ) Number of operation cycles 1000 Number of operation cycles 5 schneider-electric.com Premset Catalog 57

58 Core Units Disconnecting circuit breaker D06H - Heavy duty line protection PM The D06H uses vacuum and SSIS technology: The smallest VCB in the world, only 375mm width Rated current is 630 A With fast reclose function operating mechanism which could be motorised, it use for line protection and generator protection PM Basic equipment 3 in 1 core unit Vacuum disconnecting load-break switch providing both load breaking breaking and disconnection function Earthing switch use air technology in sealed-for-life tank at atmospheric pressure Mechanism Operating circuit breaker with stored energy type operating mechanism (O-CO-CO) with pushbutton opening and closing and spring charging using a lever, independent of operator action Heavy duty operating cycle (O-0.3 s-co-15 s-co) Anti-refl ex lever-operated mechanism for earthing switch, independent of operator action Full failsafe interlocking between the circuit breaker and earthing switch Three-phase busbars for top connection (630 A) Bottom C-type bushing for dry type cable connection or connection Three phase bottom busbar for bus coupling Voltage presence indicator Cable box Standard built-in padlocking facility With 700 mm length cable connection & 290 mm deep door For main switch, earthing switch and operation selector (shackle diameter <9 mm) Accessories Operation accessory options Connection options DM DM100013bis DM Visibility of earthing contacts Electrical operation Auxiliary contacts on switch and earthing switch Voltage present/absent contact Local/remote control switch Operation counter Additional opening coil (1) Pushbutton protection cover Locking options 1250 A three-phase upper busbars when cable connection Rear cable entry (top or bottom) connection Deeper cable box door (500 mm) Compact cable box with 500 mm length cable connection Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) Key-type interlocking main switch in open-disconnected position (1 or 2 keylocks) earthing switch in cable earthed position (1 or 2 keylocks) earthing switch in line position (1 or 2 keylocks) Interlocking between cable box door and main switch & earthing switch for front cable connection Live cable interlocking Protection relay and current transformers options Protection relay VIP 45 / 400 /410 Sepam 20, 40, 60, 80 MiCOM Easergy P5 Protection current transformer CuA or CuB TLPU1 ARU2 ARC6 Protection voltage transformer VRU1 LPVT (1) only with VIP relay 58 Premset Catalog schneider-electric.com

59 Core Units Disconnecting circuit breaker D06H - Heavy duty line protection Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 630 Rated short-time withstand current and duration I k for switchgear with tk=1 s up to ka for switchgear with tk=3 s for switchgear with tk=4 s Short-circuit breaking capacity I sc up to ka Rated making capacity of main switch and earhing switches I ma when fr=50 Hz ka peak when fr=60 Hz ka peak Capacitive breaking capacity (IEC ) Capacitive breaking class Line charging current 10A, class C2 Cable charging current 25A, class C2 Single capacitor bank: class BC2 No-load mechanical endurance of circuit breaker Electrical endurance of circuit breaker M2 class (IEC ) E2 class (IEC ) Number of operation cycles ka, reclosing duty Operating sequence (when electrical operation on circuit breaker) Maximum number of operation at 100% Isc O - 0.3s - CO-15s - CO 50 Total clearing time at Isc Fault detection to arc extinguishing ms <100 No-load mechanical endurance of earthing switch Making capacity endurance of earthing switch M0 class (IEC ) E2 class (IEC ) Number of operation cycles 1000 Number of operation cycles 5 schneider-electric.com Premset Catalog 59

60 Core Units Disconnecting circuit breaker D12H - Heavy duty line protection The D12H uses vacuum and SSIS technology : 750mm width Rated current is 1250 A With fast reclose function operating mechanism which could be motorised, it use for line protection and generator protection With Sepam auxiliary power relay, and it is also open to the other kind of auxilairy power relay Basic equipment 3 in 1 core unit Vacuum disconnecting load-break switch providing both load breaking breaking and disconnection function Earthing switch use air technology in sealed-for-life tank at atmospheric pressure Mechanism Operating circuit breaker with stored energy type operating mechanism (O-CO-CO) with pushbutton opening and closing and spring charging using a lever, independent of operator action Heavy duty operating cycle (O-0.3 s-co-15 s-co) Anti-refl ex lever-operated mechanism for earthing switch, independent of operator action Full failsafe interlocking between the circuit breaker and earthing switch PM Three-phase busbars for top connection (1250 A) Bottom C-type bushing for dry type cable connection or connection Three phase bottom busbar for bus coupling Voltage presence indicator Cable box With 700 mm length cable connection & 290 mm deep door PM Standard built-in padlocking facility Accessories For main switch, earthing switch and operation selector (shackle diameter <9 mm) Operation accessory options Visibility of earthing contacts Electrical operation Auxiliary contacts on switch and earthing switch Voltage present/absent contact Local/remote control switch Operation counter Pushbutton protection cover Connection options Rear cable entry (top or bottom) connection Deeper cable box door (450 mm) Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) DM DM100013bis DM Locking options Key-type interlocking main switch in open-disconnected position (1 or 2 keylocks) earthing switch in cable earthed position (1 or 2 keylocks) earthing switch in line position (1 or 2 keylocks) Interlocking between cable box door and main switch & earthing switch for front cable connection Live cable interlocking Protection relay and current transformers options Protection relay Sepam MiCOM Easergy p5 Protection current transformer ARU2 Protection voltage transformer VRU1 LPVT 60 Premset Catalog schneider-electric.com

61 Core Units Disconnecting circuit breaker D12H - Heavy duty line protection Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 1250 Rated short-time withstand current and duration I k for switchgear with tk=1 s up to ka for switchgear with tk=3 s for switchgear with tk=4 s Short-circuit breaking capacity I sc up to ka Rated making capacity of main switch and earhing switches I ma when fr=50 Hz ka peak when fr=60 Hz ka peak Capacitive breaking capacity (IEC ) Capacitive breaking class Line charging current 10A, class C2 Cable charging current 25A, class C2 Single capacitor bank: class BC2 No-load mechanical endurance of circuit breaker Electrical endurance of circuit breaker M2 class (IEC ) E2 class (IEC ) Number of operation cycles ka, reclosing duty Operating sequence (when electrical operation on circuit breaker) Maximum number of operation at 100% Isc O - 0.3s - CO-15s - CO 50 Total clearing time at Isc Fault detection to arc extinguishing ms <100 No-load mechanical endurance of earthing switch Making capacity endurance of earthing switch M0 class (IEC ) E2 class (IEC ) Number of operation cycles 1000 Number of operation cycles 5 schneider-electric.com Premset Catalog 61

62 Core Units Bus Riser G06, G12 PM The G06 and G12 core unit is a simple bus riser G06 can be used in various functional units: direct cable incomer, bus riser. G12 is only bus riser 375 mm width PM Basic equipment Three-phase busbars for top connection (630 A for G06, 1250 A for G12) Bottom C-type bushing for dry type cable connection for G06 connection Three phase bottom busbar for bus coupling Voltage presence indicator Cable box Accessories Connection options With 700 mm length cable connection & 290 mm deep door 1250A three-phase upper busbars when cable connection (only for G06) Rear cable entry (top or bottom) connection (only for G06) Deeper cable box door (500 mm) Compact cable box with 500 mm length cable connection (only for G06) Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 630 (G06), 1250 (G12) DM DM100023bis DM100023bis Rated short-time withstand current and duration I k for switchgear with tk=1 s for switchgear with tk=3 s for switchgear with tk=4 s up to ka G06 G06 / G12 G06 / G12 62 Premset Catalog schneider-electric.com

63 Core Units Metering M06S, M12S - SSIS compact metering The M06S and M12S core unit is a compact metering unit, insensitive to harsh environments thanks to SSIS design. A cost-effective alternative to traditional air-insulated metering units Fully compatible with the Premset system M06S could be used in wide of applications: tariff metering, metered incomer, feeders and risers, cable with VT incomer and feeder Easy to disconnect VT from front of cubicle Compact soluton, only 375 mm width Basic equipment Three-phase busbar riser with shielded solid insulation Three ring-type current transformer with shielded solide insulation (ARC5) Three phase to earth voltage transformer With shielded solid insulation (VRU1), located in front compartment to provide easy access for maintenance and esay disconnection for commissioning Three-phase busbars for top connection Bottom C-type bushing for dry type cable connection (only M06S) connection Three phase bottom busbar for bus coupling Voltage presence indicator Cable box Accessories Connection options With 700 mm length cable connection & 290 mm deep door PM PM A three-phase upper busbars when cable connection (only for M06S) Rear cable entry (top or bottom) connection (only for M06S) Deeper cable box door (500 mm) Compact cable box with 500 mm length cable connection (only for M06S) Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) Locking options Keylocking of front panel to prevent access to voltage transformer when busbar/ cable energized PM DM A DM DM Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 630 (M06S), 1250 (M12S) M06S M06S / M12S M06S / M12S Rated short-time withstand current and duration I k for switchgear with tk=1 s for switchgear with tk=3 s up to ka for switchgear with tk=4 s schneider-electric.com Premset Catalog 63

64 Core Units Metering M06A, M12A - Air-insulated metering PM The M06A, M12A core unit is a traditional air-insulated metering unit Designed for easy adaptation to any type of conventional block CT or VT Bare copper primary circuit in totally closed IP3X metal housing Wide choice of arrangement, including metered incomer, feeder, busbar metering and risers Compatible with Premset connection system 750 mm width PM Basic equipment Three-phase busbar riser: bare copper bar Two or three block-type current transformer Two or three phase to phase or phase to earth voltage transformer Three-phase busbars for top connection Bottom Connection pads for dry type cable or connection Three phase bottom busbar for bus coupling Voltage presence indicator for metering incomer or feeder Cable box Accessories With 700 mm length cable connection & 290 mm deep door Connection options 1250 A three-phase upper busbars for cable connection (only for M06A) Fuses for voltage transformer: length 360 mm, diameter 45 mm Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) Locking options Keylocking of front panel to prevent access to voltage transformer when busbar/ cable energized Choice of arrangements Bus riser metering Bus riser metering Metered feeder / incomer Busbars metering DM A DM B Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 630 (M06A), 1250 (M12A) DM DM100073bis Rated short-time withstand current and duration I k for switchgear with tk=1 s for switchgear with tk=3 s up to ka for switchgear with tk=4 s Internal arc proof, type tested A-FLR: 21kA 1 s 64 Premset Catalog schneider-electric.com

65 Core Units Metering VTM - Voltage transformer The VTM core units are voltage transformer units. Basic equipment Three-phase busbar riser with shielded solid insulation PM Three phase to earth voltage transformer with shielded solid insulation (VRU1) VTM directly connected to the busbars, dedicated to voltage metering. It is compact, only 375 mm width It is insensitive to harsh environments thanks to SSIS design Easy to disconnect VT from front of cubicle PM Three phase to earth voltage transformer with shielded solid insulation (VRU1) Three-phase busbars for top connection (630 A) Cable box With 700 mm high & 290 mm deep door Front panel which access to voltage transformer Accessories Connection options 1250A three-phase upper busbars Deeper cable box door (500 mm) Compact cable box with 500 mm high Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) Locking options Keylocking of front panel to prevent access to voltage transformer when the busbar is energized Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 630 Rated short-time withstand current and duration I k for switchgear with tk=1 s for switchgear with tk=3 s up to ka DM for switchgear with tk=4 s schneider-electric.com Premset Catalog 65

66 Core Units Metering VTM-D - Voltage transformer with circuit-breaker protection The VTM-D dedicated core unit including a D01N circuit breaker protect three phase to earth screened voltage transformer (VRU1). Directly connected to the busbars, dedicated to voltage metering. Very compact solution, only 375 mm width It is insensitive to harsh environments thanks to SSIS design Basic equipment 100 A disconnecting circuit breaker Three-phase busbars for top connection (630 A) Cable box Accessories Operation accessory options Refer to accessories of D01N core unit, page 54 With associated earthing switch (see D01, page 54) With 700 mm high & 290 mm deep door DM PM PM Premset Catalog schneider-electric.com

67 Core Units Metering VTM-D - Voltage transformer with circuit-breaker protection Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A rms 100 Rated short-time withstand current and duration I k for switchgear with tk=1 s up to ka for switchgear with tk=3 s for switchgear with tk=4 s Short-circuit breaking capacity I sc up to ka Rated making capacity of main switch and earhing switches I ma when fr=50 Hz ka peak when fr=60 Hz ka peak No-load mechanical endurance of circuit breaker Electrical endurance of circuit breaker M1 class (IEC ) E2 class (IEC ) Number of operation cycles kA Operating sequence (when electrical operation on circuit breaker) Maximum number of operation at 100% Isc CO-15s-CO 5 Total clearing time at Isc No-load mechanical endurance of earthing switch Making capacity endurance of earthing switch Fault detection to arc extinguishing M0 class (IEC ) E2 class (IEC ) ms <60 Number of operation cycles 1000 Number of operation cycles 5 schneider-electric.com Premset Catalog 67

68 Core Units Special functions VTP - Auxiliary power supply The VTP core units are voltage transformer units. Basic equipment Three phase busbar riser With shielded solid insulation VTP directly connected to the busbars and dedicated to auxiliary power supply It is compact, only 375 mm width It is insensitive to harsh environments thanks to SSIS design Easy to disconnect VT from front of cubicle Screened voltage transformer One VRU2 phase-to-phase screened voltage transformer, dedicated to auxiliary power supply (see page 83) Three-phase busbars for top busbar connection (630 A) Cable box With 700 mm high Accessories PM Connection options 1250A three-phase upper busbars Deeper cable box door (500 mm) Compact cable box with 500 mm high Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A 630 Rated short-time withstand current and duration I k for switchgear with tk=1 s for switchgear with tk=3 s up to ka DM for switchgear with tk=4 s Premset Catalog schneider-electric.com

69 Core Units Special functions VTP -D - Auxiliary power supply with circuit-breaker protection The VTP-D dedicated core unit is a D01N circuit breaker protect the phase to phase screened voltage transformer (VRU2). Directly connected to the busbars, dedicated to auxiliary power supply 375 mm width it is insensitive to harsh environments thanks to SSIS design Basic equipment SSIS design (Shielded Solid Insulation System), composed of: 100 A disconnecting circuit breaker With associated earthing switch (see D01, page 54) Three-phase busbars for top busbar connection (630 A) Cable box Screened voltage transformer With 700 mm high & 290 mm deep door One VRU2 phase-to-phase screened voltage transformer, dedicated to auxiliary power supply (see page 83) PM Accessories Operation accessory options Refer to accessories of D01N core unit, page 54. DM PM schneider-electric.com Premset Catalog 69

70 Core Units Special functions VTP -D - Auxiliary power supply with circuit-breaker protection Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A rms 100 Rated short-time withstand current and duration I k for switchgear with tk=1 s up to ka for switchgear with tk=3 s for switchgear with tk=4 s Short-circuit breaking capacity I sc up to ka Rated making capacity of main switch and earhing switches I ma when fr=50 Hz ka peak when fr=60 Hz ka peak No-load mechanical endurance of circuit breaker Electrical endurance of circuit breaker M1 class (IEC ) E2 class (IEC ) Number of operation cycles ka Operating sequence (when electrical operation on circuit breaker) Maximum number of operation at 100% Isc CO-15s-CO 5 Total clearing time at Isc No-load mechanical endurance of earthing switch Making capacity endurance of earthing switch Fault detection to arc extinguishing M0 class (IEC ) E2 class (IEC ) ms <60 Number of operation cycles 1000 Number of operation cycles 5 70 Premset Catalog schneider-electric.com

71 Core Units Special functions ES-B - Busbar earthing switch The ES-B core unit is dedicated to busbar earthing: The main application is coupled busbars (2 incomers + 1 bus coupler system) but it can also be used for any application requiring busbar earthing prior to accessing the busbars Basic equipment Earthing switch air technology Mechanism Earthing switch use air technology in sealedfor-life tank at atmospheric pressure with shielded solid insulation, totally SF6 free solution. Operating load switch with anti-refl ex leveroperated mechanism (CIT type), independent of operator action PM DM PM Three-phase busbars for top busbar connection (630 A) Cable box Standard built-in padlocking facility Accessories Connection options 1250 A three-phase upper busbars Compact cable box with 500 mm high Deeper cable box door (500 mm) Enlarged low-voltage control cabinet Raising plinth (260 mm or 520 mm) With 700 mm high & 290 mm deep door for earthing switch (shackle diameter <9 mm) Locking options Optional keylocking facilities with fl at or tubular key types 1 or 2 keylocks for locking the ES-B fonction in "open" position Auxiliary switches Auxiliary contacts on earthing switch Technical characteristics Rated voltage U r (kv) ,5 Rated current I r A rms 630 Rated short-time withstand current and duration I k for switchgear with tk=1 s up to ka for switchgear with tk=3 s No-load mechanical endurance of circuit breaker Making capacity endurance of earthing switch M1 class (IEC ) E2 class (IEC ) for switchgear with tk=4 s Number of operation cycles 1000 Number of operation cycles 5 schneider-electric.com Premset Catalog 71

72 Core Units Special functions Cable in/out function The Cable In/Out function uses vacuum and SSIS technology Compact solution, only 375 mm width Rated current is 630 A It is stand alone solution, the application could be for one transformer protection The core unit could be I06T, I06H, D01N, D02N, D06N or D06H Basic equipment 3 in 1 core unit For details refer to I06T or I06H or D01N or D02N or D06N or D06H page. Top connection Bottom connection C-type bushing for dry type cable connection (1 cable/phase) C-type bushing for dry type cable connection (1 cable/phase) Voltage presence indicator (only for front cable) PM Front cable box Rear cable box Standard built-in padlocking facility With 700 mm length cable connection & 290 mm deep door 290 mm Depth For main switch, earthing switch and operation selector (shackle diameter <9 mm) PM Only standard design (without arc control version) Accessories Operation accessory options Refer to I06T or I06H or D01N or D02N ord06n or D06H, pages 48, 54, 58. DM DM Locking options Key-type interlocking main switch in open-disconnected position (1 or 2 keylocks) earthing switch in cable earthed position (1 or 2 keylocks) earthing switch in line position (1 or 2 keylocks) Interlocking between cable box door and main switch & earthing switch for front cable connection Live cable interlocking (only for front cable) Other options Fault passage indicators for front cable Cable test device (only for front cable) Visibility of earthing contacts Note: the cubicle is non-iac version 72 Premset Catalog schneider-electric.com

73 Core Units Operating mechanisms Introduction PM Three spring charge store energy operating mechanisms meet all the needs of the various core units of the Premset range. They provide user-friendly operation over the entire life of your switchgear. They share the same range of auxiliairies for electrical operation and remote indications. A rational range of operating mechanisms CIT CI1 OCO Units Type of operating mechanism I06T p I06H p I12H p D01N,D02N,D06N p D06H p D12H p VTM-D,VTP-D p ES-B p PM CIT mechanism in I06T unit CI1 mechanism in D02N unit Three operating mechanisms have been designed together with the core units to optimize performance and ensure user-friendly operation. They are totally integrated within the core units and will operate over the total life expectancy of the switchgear. Periodic checkup of the mechanism can be done to ensure the performance depending on the environmental conditions. All three mechanisms share the same features: Intuitive operation principles Position indications and easy-to-read mimic diagrams Range of auxiliary including motor-mechanism, opening coils (MX, MN), closing coils (XF) and auxiliary switches Range of accessories including padlocking and keylock devices Earthing switch mechanism, fully interlocked with the main device PM OCO mechanism in D06H unit Specific care has been taken to reinforce the harsh environment withstanding on mechanism and auxiliaries as well: Specifi c care has been taken to select the mechanism parts plating and tested accordingly in harsh environment Tripping and operating coil are encased in a sealed core, so protected against condensation and droping water Motor is encased in a protection aluminium cover Auxiliary switches are sealed-type, waterproof schneider-electric.com Premset Catalog 73

74 Core Units Operating mechanisms Introduction PM PM PM CIT mechanism in I06T unit CI1 mechanism in D02N unit OCO mechanism in D06H unit Double-function operating mechanism CIT Switch function independent-operation opening or closing by lever or motor Earthing-switch function: Independent-operation opening or closing by lever operating energy is provided by a compressed spring which causes the contacts to open or close when released Auxiliary contacts - switch 1 or 2 block (2NO+2NC/block) - earthing switch 1 or 2 block (1NO+1NC/block) (1) Motor option Operation counter Double-function operating mechanism CI1 Circuit breaker function - independent-operation closing by lever or motor - operating energy is provided by a compressed spring which causes the contacts to open or close when released - independent-operation opening or closing by push button (O) or trip unit Earthing-switch function: independent-operation opening or closing by lever. Operating energy is provided by a compressed spring which causes the contacts to open or close when released Auxiliary contacts - switch 1 or 2 blocks (2NO+2NC/block) - earthing switch 1 or 2 blocks (1NO+1NC/block) (1) Motor option opening releases - low Energy shunt trip (Mitop) with SDE contact - open release (MX) - undervolatge release (MN) operation counter Double-function operating mechanism OCO Switch or circuit breaker function - independent-operation closing by two steps: 1. operating mechanism recharging by lever or motor 2. stored energy released by push-button (I) or trip unit - independent-operation opening by push button (O) or trip units Earthing-switch function: independent-operation opening or closing by lever. Operating energy is provided by a compressed spring which causes the contacts to open or close when released Auxiliary contacts - switch 1 or 2 blocks (2NO+2NC/block) - earthing switch 1 or 2 blocks (1NO+1NC/block) (1) Motor option Closing releases Opening releases - low energy shunt trip (Mitop) with SDE contact - open release (MX) - undervolatge release (MN) Operation counter (1) When motor is selected, only 1 block earthing switch auxiliary contact is available 74 Premset Catalog schneider-electric.com

75 Core Units Operating mechanisms Accessories PM Motor mechanism (MCH) The MCH electrical motor mechanism is used to charge the main springs that store the operating energy for the core unit mechanism. on the CIT mechanism, it allows electrical opening and closing of the core unit. on the CI1 mechanism, it allows electrical charging and closing of the core unit. on the OCO mechanism, it allows electrical charging of the core unit The motor mechanism is equipped with a spring charged limit switch that stops spring charging when the springs are fully charged. This contact is also used to indicate the spring charged status. Characteristics Power supply 24-30VDC 48-60VDC/AC VDC/AC VDC/AC Threshold 0.85 to 1.1 Un Consumption (VA or W) 180 Motor overcurrent 2 to 3 In for 0.1 s PM Shunt closing release (XF) and opening release (MX) XF shunt closing release: This release, dedicated to the OCO mechanism, allows electrical closing as soon as the springs are charged. MX shunt trip release: This release, dedicated to the CI1 or OCO mechanisms, allows electrical opening of the core unit. It can lock the unit in open position as long as the remote order is maintained. Characteristics Power supply 24-30VDC 48-60VDC/AC VDC/AC VDC/AC Threshold XF 0.85 to 1.1 Un * MX 0.7 to 1.1 Un Consumption Triggering 250 (VA or W) Latched 2.5 * please consult us when you need more than 1.1Un PM Undervoltage release (MN) This release allows the electrical opening of the core unit in the event of an undervoltage. It can be used also for positive opening and locking in case of an emergency caused by a voltage drop, loss of auxiliary power. It can be associated with a time delay unit. Characteristics Power supply 24-30VDC 48-60VDC/AC VDC/AC VDC/AC Threshold Opening 0.35 to 0.7 Un Closing 0.85 Un Consumption Triggering 250 (VA or W) Latched 2.5 schneider-electric.com Premset Catalog 75

76 Core Units Operating mechanisms Accessories MT66042 Time delay for MN To eliminate spurious tripping of the circuit breaker when there are brief voltage drops, the MN action is controlled with a time delay. This function is achieved by adding a time delay unit outside of the undervoltage release (MN) circuit (adjustable time delay). This unit is placed outside the circuit breaker and can be inhibited by an emergency stop button to obtain instant circuit breaker opening. Characteristics Power supply See 'Order Form' page Threshold Opening Closing 0.35 to 0.7 Ur 0.85 Ur Consumption (VA or W) Time delay Triggering 200 (for 200 ms) Latched s s s - 3 s PM Rotary type contacts (OC) On/Off auxiliary position contacts These auxiliary contacts indicate the open or closed position of the circuit breaker. Rotary type changeover contacts directly controlled by the circuit breaker mechanism. Indication contacts are proposed: - for standard relaying applications - for low level control applications with PLCs or electronic circuits This version is compatible with Sepam series 20, series 40 and series 80 units. Characteristics Breaking capacity (A) Standard Minimum load: 100 ma/24 V Cos : 0.3 Utilisation category: AC12/DC12 V AC 240/380 10/6 (1) /6 (1) V DC 24/48 10/6 (1) /6 (1) (1) Standard contacts: 10 A Optional contacts: 6 A (temperature derating) 76 Premset Catalog schneider-electric.com

77 Core Units Operating mechanisms Padlocking and keylocking It is also possible to padlock the push button cover (option). Padlocking Current cubicle design provides the possibility to padlock the following devices: Electrical operation inhibition switch Cable test access Earthing switch PM100011b Connection compartment Main/Earthing switch operation selector Main switch and spring arming (according to the core unit type) schneider-electric.com Premset Catalog 77

78 Core Units Operating mechanisms Padlocking and keylocking The key lock configuration can be modified after commissioning. Keylocking (optional) Up to 7 key lockings available as an option on the switching device. Live cable interlock Overide key lock position PM Main lock for locking the earthing switch in the line/open position Main lock for locking the main switch selector in the open and disconnected position Main lock for locking the earthing switch in the earthed/ closed position Additional lock for locking the earthing switch in the line/open position Additional lock for locking the main switch selector in the open and disconnected position Additional lock for locking the earthing switch in the earthed/ closed position These 6 Key lock options provide the possibility to have interlocking between/among different cubicles. 78 Premset Catalog schneider-electric.com

79 Core Units SSIS Current and voltage Transformer for Premset Unit type Current sensors Synthesis table by unit Protection sensors Zero sequence Under core unit Cable Bushing Cable Bushing Cable Rising CT CuA CuB TLPU1 ARU2 CSH120 CSH200 FPI & Ammeter Metering CT Screened Voltage sensors Busbar or cable Busbar CTR2200 MF1 ARU1 ARC6 ARC5 VRU1 VRU2 I06T p p p p p I06H p p p p p I12H p p D01N p p p p p p p p p D02N p p p p p p p p p D06N p p p p p p p p p D06H p p p p p p p p p D12H p p p p p M06S p p M12S p p VTM p VTM-D p VTP VTP-D p p DM CuA, CuB Dedicated current sensors (power and measurement) CSH120/200 Optional zero sequence sensor for high sensitive earthing fault protection CuA, CuB The sensors are dedicated design for Premset self power protection system which includes sensors, VIP relay and an actuator. The sensors are made up of one block of three CTs, it provides protection function and the measurement function, also it provide power for an actuator. The sensors are located under the core unit: Characteristics according to IEC Double secondary winding for measurement and protection Frequency 50-60Hz Characteristics Highest voltage for equipement Um 0.72 kv Power frequency withstand voltage 3 kv - 1 min Rated short-time withstand current Ith (ka) 25 Withstand time t (s) 3 Rated primary current Ipr CuA: A, CuB:0-630 A Secondary voltage Us 22.5 mv at rated primary current Rated burden > 2 k Measurement Accuracy CI 1.0 Protection class 5P30 schneider-electric.com Premset Catalog 79

80 Core Units SSIS Current and voltage Transformer for Premset CSH120/200 For Sepam or third party protection relays, if the sensitive earth fault protection is required, an earth fault toroidal CT of the CSH120 or CSH200 type around the cables should be installed. CSH120 and CSH200 core balance CT s, provide more sensitive protection by the direct measurement of earth fault currents. CSH mm internal diameter CSH mm internal diameter DM TLPU1 (LPCT) Low Power Current Transfomers (TLPU1) use optimised technology that offers a number of advantages in Premset cubicles. Simpler selection: a single sensor can be used for both measurement or protection over the entire range of operating currents Easy and safe installation: the LPCT output is plugged directly into the Sepam relay with no risk of overvoltage when disconnecting Flexibility of use: easy adaptation to changes in power levels and/or protection settings during MV system design or service life High accuracy up to the short-time circuit current with low saturation Compact design: small size and weight allow easy integration in Premset cubicles Comply to IEC One secondary winding for measurement or protection Frequency 50-60Hz Characteristics Highest voltage for equipement Um 0.72 kv Power frequency withstand voltage 3 kv - 1 min Rated short-time withstand current Ith (ka) 25 Withstand time t (s) 3 Rated primary current Ipr 100 A Secondary voltage Us 22.5 mv Rated burden > 2 k Measurement Accuracy class 0.5 up to Ipr 630 A Protection 5P250 PM * please consult us for availability New LPVT options * Premset can now be specified with compact high accuracy Low Power Voltage Transformer. The innovative sensors are ideal for the new generation of electronic protection devices and monitor energy consume: Up to Class 0.5 accuracy levels for metering Linear wide spectrum voltage range with no ferro resonance characteristics Low power consumption and reduced size -ideal for new or retrofi t solutions Excellent harmonic performance for Power Quality monitoring Increased quality and safety under over-voltage, open circuit, or short circuit conditions Easy to install, operate and test Comply to IEC Premset Catalog schneider-electric.com

81 Core Units SSIS Current and voltage Transformer for Premset DM ARU2 A standard ring type current transformer of the ARU2 type (1A, 5P20 class) can be located under the core unit. Characteristics according to IEC One secondary winding for protection Frequency 50-60Hz ARU2 CTs Characteristics D01N,D02N,D06N,D06H D12H Rated primary and lpr/lsr(a) 100/1 200/1 400/1 600/1 800/1 1000/1 1250/1 secondary current Rated short-time Ith (ka) current Withstand time t (s) 3 s 3 s 3 s Protection Rated 1.5 VA 2.5 VA 5 VA burden Accuracy class 5P-20 Note: Please consult us for the availability of the other current ratios and performances Three different types of current transformers (ARU1, ARC6 and ARC5) are used for tariff metering on Premset switchboards. They are all designed for easy installation and long service life. Compliance with standard IEC and 50/60 Hz frequency for all current transformers. DM ARU1 The ARU1 is a block comprising three ring-type current transformer. The ARU1 is located around bushing, for all of switchgear units: I06T, I06H, D01N, D02N, D06N, D06H, I12H and D12H ARU1 ARC6 Characteristics I06H, I06T, D01N, D02N, D06N, D06H, G06 I12H, D12H Rated primary and lpr/lsr(a) 100/1 200/1 400/1 600/1 300/5 400/5 600/5 800/5 1000/5 1250/5 secondary current Rated short-time Ith (ka) current Withstand time t (s) 3 s 3 s Measurement Rated burden 2.5 VA 5 VA Accuracy class CI 0.5 s CI 0.2 s Fs 5 Note: Please consult us for the availability of the other current ratios and performances schneider-electric.com Premset Catalog 81

82 Core Units SSIS Current and voltage Transformer for Premset PE90925 ARC6 The ARC6 is a ring-type current transformer. The ARC6 is located around cable, for all of switchgear units: I06T, I06H, D01N, D02N, D06N, D06H and D12H. (1) The ARC6 offers higher accuracy than ARU1 when primary current less 630A. The ARC6 only installed on single-core screened cable, with deeper cable compartment door. * please consult us for availability Characteristics * Rated primary and lpr/lsr(a) 100/5 150/5 200/5 300/5 400/5 600/5 secondary current Rated short-time Ith (ka) current Withstand time t (s) 3 s 3 s Measurement Rated burden 5 VA 15 VA Accuracy Cl 0.2s FS 5 class * Except for D12H Note: Please consult us for the availability of the other current ratios and performances PE58382 ARC5 The ARC5 is a ring-type current transformer used in the M06S, M12S metering core unit. Compact dimensions for easy installation on a Premset bus riser. Cost-effective compared to standard MV CT block or DIN solutions Characteristics M06S M12S Rated primary and lpr/lsr(a) 100/5 200/5 400/5 600/5 800/5 1000/5 1205/5 secondary current Rated short-time Ith (ka) current Withstand time t (s) 3 s 3 s Measurement Rated 5 VA 5 VA burden Accuracy class Cl 0.2s FS 5 Note: Please consult us for the availability of the other current ratios and performances 82 Premset Catalog schneider-electric.com

83 Core Units SSIS Current and voltage Transformer for Premset Different types of voltage transformers are used for tariff metering on Premset switchboards. They are all designed for easy installation and long service life. Compliance with standard IEC and 50/60 Hz frequency for all voltage transformers. By using Phase-Earth VTs connected between phase and earth in a NOT solid earthed neutral system is the most favourable case for ferroresonance to occur. In order to face ferroresonance issues it is always advisable to use the following solutions (mandatory one of the two): The usage of a dumping resistor connected to the open delta terminals of the residual voltage secondary circuit will help to dump ferroresonance. The usage of VTs working at lower induction level to avoid that over voltages could initiate ferroresonance. The offer of lower induction VTs is available on request depending on the neutral system status, please contact us PE58411 VRU1 The VRU1 is a phase-to-earth screened voltage transformer used in SSIS M06S, M12S, VTM and VTM-D metering core units. VRU1 is also uses for incomer or feeder cubicle (I06T,I06H,I12H, D01N,D02N,D06N, D06H, D12H) for embedded metering, installed behide cable Compact dimensions and design for easy installation in Premset core units Easy front access for disconnection for commissioning SSIS design for insensitivity to harsh environments Characteristics Rated voltage kv Primary voltage kv 6/3 6.6/3 6/3 10/3 11/3 10/3 11/3 13.8/3 15/3 Rated insulation and lighting impulse voltage kv 20/60 20/60 32/60 28/75 28/75 42/75 38/95 38/95 38/95 1 st secondary voltage V Rated burden and accuracy class 10 VA Cl nd secondary voltage V 100/3 110/3 100/3 100/3 110/3 100/3 110/3 110/3 100/3 Rated burden and accuracy class 30 VA 3P Note: Please consult us for the availability of the other current ratios and performances PE58412 VRU2 for auxiliary power supply The VRU2 is a phase-to-phase screened voltage transformer used in VTP and VTP-D auxiliary power supply functions. Compact dimensions and screened design for easy installation in Premset core units, insensitivity to harsh environments. Designed to withstand power frequency tests (no need for disconnection during commissioning) Power: 300 VA continuous, 500 VA for 1 minute Characteristics Rated voltage kv Primary voltage kv Rated insulation and lighting impulse voltage 1 st secondary voltage Rated burden and accuracy class kv 20/60 20/60 32/60 28/75 28/75 42/75 38/95 38/95 V VA cl 3 schneider-electric.com Premset Catalog 83

84 Core Units AIS Current and voltage Transformer for Premset Synthesis table by unit Current sensors Unit type Metering CT Block DIN Block Block CT Phase-Earth Phase-Phase Phase-Earth Phase-Phase AD12 AD13 ARM3 ARJP3 VDF11/21 VDC11/21 VRQ2 VRC2 M06A p p p p p p M12A p p p p p p Three different types of current transformers are used for tariff metering on Premset switchboards. They are all designed for easy installation and long service life. Compliance with standard IEC and 50/60 Hz frequency for all current transformers. DE52378 AD12 PE58379 AD13 AD12 and AD13 AD12 and AD13 are the medium voltage current transformer used in the M06A and M12A air-insulated metering core unit. Widely used type of current transformer with overall dimensions in accordance with DIN Teil 8 standard 12 kv size High accuracy over the entire measurement range. Single primary winding One secondary winding for metering (1) AD12 characteristics Rated primary and secondary current Ipr/Isr (A) 50/5 100/5 200/5 400/5 600/5 Rated short-time withstand current Ith (ka) 25 Withstand time t (s) 1 Measurement Rated burden (min-max) VA VA Accuracy Cl 0.2s Fs<5 class AD13 characteristics Rated primary and Ipr/Isr (A) 800/5 1000/5 1200/5 secondary current Rated short-time Ith (ka) 25 withstand current Withstand time t (s) 1 Measurement Rated burden (min-max) Accuracy class VA Cl 0.2 s Fs<5 Note: Please consult us for the availability of the other current ratios and performances 84 Premset Catalog schneider-electric.com

85 Core Units AIS Current and voltage Transformer for Premset PE58383 ARM3 The ARM3 is a block type medium voltage current transformer used in the M06A and M12A air-insulated metering core unit. Standard type of current transformer for Schneider Electric applications. High accuracy over the entire measurement range. Single primary winding One secondary winding for metering(1) Characteristics Rated primary and Ipr/Isr (A) 50/5 100/5 200/5 400/5 600/5 secondary current Rated short-time Ith (ka) 25 withstand current Withstand time t (s) 1 Measurement Rated burden (min-max) Accuracy class VA Cl 0.2 s Fs<5 Note: Please consult us for the availability of the other current ratios and performances PE58389 ARJP3 The ARJP3 is a block type medium voltage current transformer used in 12A air-insulated metering core unit. Standard type of current transformer for Schneider Electric applications High accuracy over the entire measurement range Single primary winding One secondary winding for metering and one for protection Characteristics Rated primary and Ipr/Isr (A) 800/ / /5-5 secondary current Rated short-time Ith (ka) 25 withstand current Withstand time t (s) 1 Measurement Rated burden & accuracy class Rated burden & accuracy class 30 VA CI VA 5P20 Note: Please consult us for the availability of the other current ratios and performances schneider-electric.com Premset Catalog 85

86 Core Units AIS Current and voltage Transformer for Premset Different types of voltage transformers are used for tariff metering on Premset switchboards. They are all designed for easy installation and long service life. Compliance with standard IEC and 50/60 Hz frequency for all voltage transformers. By using Phase-Earth VTs connected between phase and earth in a NOT solid earthed neutral system is the most favourable case for ferroresonance to occur. In order to face ferroresonance issues it is always advisable to use the following solutions (mandatory one of the two): The usage of a dumping resistor connected to the open delta terminals of the residual voltage secondary circuit will help to dump ferroresonance. The usage of VTs working at lower induction level to avoid that over voltages could initiate ferroresonance. The offer of lower induction VTs is available on request depending on the neutral system status, please contact us PM PE58401 VDF11 and VDF21 VDF11 and VDF21 phase-to-earth voltage transformers are used in the M06A and M12A air-insulated metering unit. Widely used type of voltage transformer with overall dimensions in accordance with DIN Teil 9 standard 17.5 kv size Easy to adapt to local practices or specifications. VDF11 VDF21 Characteristics VDF11 VDF21 Rated voltage kv Primary voltage kv 3/3 to 6.6/3 6/3 6/3 to 11/3 10/3 10/ 3 to 15/ 3 Rated insulation and lighting impulse voltage V 20/60 32/60 28/75 42/75 38/95 1 st secondary voltage V 100/3 or 110/3 100/3 100/3 or 110/3 Rated burden and accuracy class 5 VA to 10 VA class 0.2, or 5 VA to 20 VA class /3 100/ 3 or 110/3 2 nd secondary voltage V 100/3 or 110/3 Rated burden and accuracy class 30 VA 3P 100/3 100/3 or 110/3 100/3 100/3 or 110/3 Note: Please consult us for the availability of the other current ratios and performances PE58446 PE58398 VDC11 and VDC21 VDC11 VDC21 VDC11 and VDC21 phase-to-phase voltage transformers are used in the M06A and M12A air-insulated metering unit. Widely used type of voltage transformer with overall dimensions in accordance with DIN Teil 9 standard 17.5 kv size Easy to adapt to local practices or specifications Characteristics VDC11 VDC21 Rated voltage kv Primary voltage kv 3 to to to 15 Rated insulation and lighting impulse voltage V 20/60 32/60 28/75 42/75 38/95 1 st secondary voltage V 100 or or 110 Thermal power an accuracy class 5VA to 10VA class 0.2, or 5VA to 20VA class or 110 Note: Please consult us for the availability of the other current ratios and performances 86 Premset Catalog schneider-electric.com

87 Core Units AIS Current and voltage Transformer for Premset PE58408 VRQ2 VRQ2 VRQ2 phase-to-earth voltage transformers are used in the M06A and M12A air-insulated metering unit. Standard type of voltage transformer for Schneider Electric applications, VRQ2 and VRC2 already used in SM6 and RM6 metering cubicles. Characteristics Rated voltage kv Primary voltage kv 3/3 to 6.6/3 6/3 6/3 to 11/3 10/3 10/3 to 15/3 Rated insulation and lighting impulse voltage V 20/60 32/60 28/75 42/75 38/95 1 st secondary voltage V 100/3 or 110/3 100/3 100/3 or 110/3 Rated burden and accuracy class 5 VA to 30 VA class 0.2, or 5 VA to 50 VA class nd secondary voltage V 100/3 or 110/3 Rated burden and accuracy class 30 VA 3P 100/3 100/3 or 110/3 100/3 100/3 or 110/3 100/3 100/3 or 110/3 Note: Please consult us for the availability of the other current ratios and performances PE58403 VRC2 VRC2 VRC2 phase-to-earth voltage transformers are used in the M06A and M12A air-insulated metering unit. Standard type of voltage transformer for Schneider Electric applications, VRC2 or already used in SM6 and RM6 metering cubicles Characteristics Rated voltage kv Primary voltage kv 3 to to to 15 Rated insulation and lighting impulse voltage V 20/60 32/60 28/75 42/75 38/95 1 st secondary voltage V 100 or or 110 Rated burden and accuracy class 5VA to 30VA class 0.2, or 5VA to 50VA class or 110 Note: Please consult us for the availability of the other current ratios and performances schneider-electric.com Premset Catalog 87

88 Protection, monitoring and control 88 Premset Catalog schneider-electric.com

89 Protection, monitoring and control Protection 90 Selection guide 90 VIP 40 and VIP VIP 400 and VIP VIP integrated system 97 Protection relay selection 98 Fault passage indicators 100 Flair 21D, 22D and 23DM 100 Voltage indicator and relay 103 VPIS and VDS 103 VD23 voltage relay 104 Live cable interlock 105 Functions 105 Thermal monitoring 106 Easergy T110: wireless thermal sensors 106 Integrated measurement 107 AMP21D ammeter 107 PM5000 series Power Meter 108 PM800 series Power Quality Meter 109 Control 110 SC110: electrical operation auxiliaries 110 Architecture of feeder automation 111 Easergy R200 :control unit 112 ATS100: automatic transfert system 114 PS100: high-availability power supply 116 schneider-electric.com Premset Catalog 89

90 Protection, monitoring and control Protection Selection guide PM VIP self-powered integrated protection Optimised performance for Premset PM VIP 40 and VIP 45 VIP 400 and VIP 410 Integrated protection relay - complete engineered and pre-tested protection system: dedicated CT and low power actuator (Mitop) - savings on space and cabling time Self-powered protection Optimised for Premset: core unit switchgear and protection designed to work together in an optimum manner: - optimisation of the breaking time Simple protection, easy to implement Perfectly adapted to dedicated applications. VIP 40 and VIP 45: designed for D01N and D02N transformer protection circuit breakers MV/LV 100 A (D01N) or 200 A (D02N) transformer protection Dedicated protection curve to protect against overloads, short-circuits and earth faults with straight-forward settings Fast clearing time or transformer short-circuits (< 60 ms): no fuse needed. VIP 400 and VIP 410: designed for D06N and D06H general protection circuit breakers Substation protection (incomers, feeders, bus risers) using D06N (standard duty) or D06H (heavy duty) 630 A circuit breakers MV/LV transformer protection instead of VIP 40 and VIP 45 if more functions are required DT (Defi nite Time) and standard IDMT (Inverse Defi nite Minimum Time) tripping curves Switchgear diagnostics Multi-language display VIP 410 includes a dual supply (self-powered plus auxiliary) for communication and high sensitivity earth fault protection. High sensitivity sensors A VIP integrated protection system is composed of sensors, a processing unit and an actuator, designed together to provide the highest level of reliability and sensitivity from 0.2 A to 20 In for VIP 400 and VIP 410 and 5 A to 20 In for VIP 40 and VIP 45 (see page 93). 90 Premset Catalog schneider-electric.com

91 Protection, monitoring and control Protection Selection guide PE88030 Sepam series Sepam series Protection relays of the Sepam series are also available and have the following characteristics: External auxiliary power Open range From basic to more sophisticated protection Standard CTs and trip actuators (see page 79). PM MiCOM series MiCOM protection provides the user with a choice of cost-optimised solutions for specifi c protection requirements within the distribution network. The MiCOM relay series offers comprehensive protective function solutions for all power supply systems as well as for various functional and hardware project stages. PM MiCOM series Easergy P5 series Easergy P5 series: a fusion of new ideas and proven expertise Easergy P5 relays provide best-in-class protection for all types of installations, together with new smart grid features and a lower total cost of ownership. Fast delivery and multivendor interoperability make the range that much simpler to integrate into your electrical network. Furthermore, a unique combination of modern features and proven components make it the right choice for forward-looking network operators. Easergy protection relays bring new benefi ts in addition to compliance with the latest international standards: Enhanced safety and security Outstanding ease of use Greater effi ciency Optimised total cost of ownership The Easergy P5 series includes a variety of models: P5 (20TE) Current or voltage P5 (30TE) * Current and Voltage Feeder P5F20 P5F30 With directional Voltage P5V20 Motor P5M20 P5M30 Generator P5G30 * Please consult us for availability schneider-electric.com Premset Catalog 91

92 Protection, monitoring and control Protection Selection guide VIP series Integrated self-powered protection optimised for Premset Sepam / MiCOM series General Easergy series Protection functions Transformer protection General protection VIP 40 VIP 45 VIP 400 VIP 410 Sepam MiCOM P5 Phase overcurrent (ANSI 50-51) p p p p p p p Earth fault phase (ANSI 51N) Standard (sum of current method) p p p p p p High sensitivity (earth fault CTs) p p p p Thermal overload (ANSI 49) p p p p p Cold load pick-up p p p p Other protection functions (1) p p p Measurement functions Phase current p p p p p p p Earth current p p p p p p Phase peak demand current p p p p p p p Load history Cumulative time p p p p p Control and monitoring functions Trip indication Local (with origin of the fault) p p p p p p p Remote (one contact) p p p p p p p Output relays p (2) p p p Trip circuit supervision (ANSI 74TC) p p p p p p p Time-tagged events Local on display (5 last trips) p p p p p Remote, via communication p p p p External tripping input p p p p Overcurrent and breaking profi le Number of phase and earth trips (3) p p p p p Serial communication port Modbus RS485 p p p p Digital inputs/outputs for control functions p p p Power supply Type of supply Self-powered or auxiliary Self Self Self Dual (4) Auxiliary Auxiliary Auxiliary Minimum 3 phase load currents to activate the VIP 4 A 4 A 7 A (5) (1) See Sepam user guide. (2) Signalling relays: (use of output relays may be change): O1 = phase fault (I>, I>>, I>>>) O2 = earth fault (Io>, Io>>) O3 = thermal overload alarm. (3) The number of trips is displayed in 4 levels: For D01 and D02: < 200 A, < 2 ka, < 8 ka, > 8 ka For D06 and D06H: < 630 A, < 10 ka, < 20 ka, > 20 ka. (4) The protection is self-powered. Auxiliary power is used only for communication and high sensitivity earth fault protection. (5) 14 A with 630 A CBs. 92 Premset Catalog schneider-electric.com

93 Protection, monitoring and control Protection VIP 40 and VIP 45 Schneider Electric recommends circuit breakers for transformer protection instead of fuses. They offer the following advantages: Easy to set Better discrimination with other MV and LV protection devices Improved protection performance for inrush currents, overloads, low magnitude phase faults and earth faults Greater harsh climate withstand Reduced maintenance and spare parts Availability of additional functions such as measurement, diagnostics and remote monitoring And with the recent development of low cost circuit breakers and self-powered relays, life time costs are now equivalent to those of traditional MV switch fuse solutions Application Entry level MV/LV transformer protection Dependent-time phase overcurrent tripping curve dedicated to MV/LV transformer protection Defi nite-time earth fault protection Phase current and peak demand current measurement Main features Self-powered operation Energised by the CTs: no auxiliary power needed Complete pre-tested protection system Functional block ready to be integrated Designed for Premset to protect transformers Designed for D02N 200 A and D01N 100 A circuit breakers to replace fuseswitch solutions Setting is as simple as fuse selection Maximum setting possibilities consistent with circuit breaker characteristics PM Phase overcurrent protection Tripping curve optimised for MV/LV transformer protection Protection against overloads and secondary and primary short-circuits Second harmonic restraint fi ltering Only one setting (I >) Discrimination with LV circuit breakers or LV fuses Compliant with TFL (Time Fuse Link) operating criteria Earth fault protection Defi nite-time tripping curve Settings: Io > (phase current sum method) and to > Second harmonic restraint element Measurement Load current on each phase Peak demand current. Front panel and settings Current measurements displayed on a 3 digit LCD Settings with 3 dials (I >, Io >, to >) protected by a lead-sealable cover Trip indication powered by dedicated integrated battery with reset by pushbutton or automatically schneider-electric.com Premset Catalog 93

94 Protection, monitoring and control Protection VIP 40 and VIP 45 DM Dual core CTs in a block under the core unit VIP Dual core CTs: for power and for measurement Mitop Other features Complete pre-tested solution that eliminates complicated CT selection Complies with MV protection relay standard IEC No PC or specifi c tool required for setting or commissioning Maximum setting possibilities consistent with circuit breaker features Self-powered by dual core CTs: CuA Environment: -40 C / +70 C. Primary injection test A primary injection circuit may be permanently installed (option) through the CTs, inside the Premset cubicle, to test the physical integrity of the complete protection system including the CTs The test is carried out without disconnecting the CTs and the VIP 40 and VIP 45 displays the injected current during testing If required, a temporary VIP 40 and VIP 45 test mode can be activated to test the tripping of the circuit breaker by pressing a test pushbutton. Test with the Pocket Battery module This accessory can be connected on the VIP 40 and VIP 45 front plate to energise the relay to carry out a quick test even when the relay is not powered (the temporary VIP 40/45 test mode can be activated for the circuit breaker). PB Pocket battery Pocket battery for VIP This unit is used to power the VIP 40, VIP 45, VIP 400 and VIP 410 units, making it possible to operate and test the protection system. It can also be used to power Schneider Electric LV circuit breakers. 94 Premset Catalog schneider-electric.com

95 Protection, monitoring and control Protection VIP 400 and VIP 410 VIP 400 is a self-powered relay energised by the CTs; it does not require an auxiliary power supply to operate VIP 410 is a dual powered relay offering self-powered functions and additional functions powered by an AC or DC auxiliary supply Applications MV distribution substation incomer or feeder protection relay MV/LV transformer protection. VIP 410 ready for smart grids Dual supply for communication with: DMS and RTUs Remote alarming Time stamped events PM Measurements of current, load history, overcurrent and breaking profi le Dedicated to intelligent MV loops with automation: Remote confi guration Setting groups selectable according to the configuration of the MV loop Remote asset management Plug and play system with Easergy RTUs (R200) to integrate all protocols (IEC , DNP3, IEC 61850) and remote Web pages Main features VIP 400: Self-powered protection relay This version is energised by the current transformers (CTs). It does not require an auxiliary power supply to operate. Overcurrent and earth fault protection Thermal overload protection Current measurement functions VIP 410: Dual powered protection relay Offers the same self-powered functions as the VIP 400 In addition, the VIP 410 has an AC or DC auxiliary supply to power certain - Additional functions that cannot be self-powered - Sensitive earth fault protection - External tripping input - Cold load pick-up - Communication (Modbus RS485 port) - Signalling If the auxiliary power fails during an MV short-circuit, the protection functions are maintained schneider-electric.com Premset Catalog 95

96 Protection, monitoring and control Protection VIP 400 and VIP 410 DM VIP Test pocket battery Other features Designed for Premset D02N 200 A and D06N 630 A circuit breakers Complete pre-tested solution that eliminates complicated CT selection Complies with MV protection relay standard IEC No PC or specifi c tool required for setting or commissioning Self-powered by dual core CTs Environment: - 40 C / +70 C. Injection test case Tests of protection system and circuit breaker Primary injection test A primary injection circuit may be permanently installed (option) through the CTs, inside the Premset cubicle, to test the physical integrity of the complete protection system including the CTs. The test is carried out without disconnecting the CTs and the VIP relay displays the injected current during testing If required, a temporary VIP test mode can be activated to test the tripping of the circuit breaker by pressing a test pushbutton. Test with the Pocket Battery module This accessory can be connected on the VIP relay front plate to energise the relay to carry out a quick test even though the relay is not powered. This module also makes it possible to test the circuit breaker. PB Pocket battery Pocket battery for VIP This unit is used to power the VIP 40, VIP 45, VIP 400 and VIP 410 units, making it possible to operate and test the protection system. It can also be used to power Schneider Electric LV circuit breakers. 96 Premset Catalog schneider-electric.com

97 Protection, monitoring and control Protection VIP integrated system The VIP series is an integrated protection system: Dedicated sensors located under the core unit provide protection and measurement outputs Optional additional earth fault sensors are available Actuators are low power tripping coils (Mitop). High sensitivity sensors VIP integrated protection system The VIP integrated protection system is composed of sensors, a processing unit and an actuator, designed together to provide the highest level of reliability and sensitivity from 0.2 A to 20 In for VIP 400 and VIP 410 and 5 A to 20 In for VIP 40 and VIP 45. Actuators The actuator is a dedicated low power tripping coil (Mitop) specifi cally designed to operate with the sensors and the processing unit with minimum energy. The integrity of the Mitop circuit is continuously supervised (Trip Circuit Supervision function). Connection diagrams VIP 40, VIP45 & VIP 400 DM Injection test L1 L2 L3 Mitop Test pocket battery VIP 410 DM Injection test L1 L2 L3 Mitop Communication RS485 Ext. trip OC EF Thermal AC/DC supply Test pocket battery schneider-electric.com Premset Catalog 97

98 Protection, monitoring and control Protection Protection relay selection Sepam, MiCOM and Easergy Sepam series 20/40 MiCOM series 20 Easergy P5 New Function PE90511 PE90366 PM Phase and earth-fault Feeder With directional (1) With line differential With distance Voltage Voltage and frequency (1) Transformer Motor Generator Busbar Capacitor bank Sensors Phase and earth-fault With transformer differential Phase and earth-fault With voltage (1) With machine differential Phase and earth-fault With directional (1) With machine differential With busbar differential CT (1 or 5 A) or LPCT VT CT (1 or 5 A) VT CT (1 or 5A) VT Display Standard UMI Remote UM Standard UMI Standard UMI Other characteristics Withdrawable hardware Withdrawable hardware Input/Output (up to) 10/8 12/11 10/8 I/O terminals Screw type Ring lug Ring lug Screw type Temp. sensors (up to) 8 or 16 (1) 10 (motor) 8 Communication Modbus RTU Modbus RTU Modbus RTU protocol IEC IEC Modbus TCP/IP DNP3 Modbus TCP/IP (1) (2) IEC RSTP DNP3 IEC Logic equations Comprehensive logic Basic logic equations Matrix equations (1) Standards IEC, EAC, CE, UL, CSA IEC, EAC, CE, UL, CSA Cyber security (IEC 62351) IEC, CE, UL, CSA, EAC (1) Sepam 40 series (2) Without GOOSE message 98 Premset Catalog schneider-electric.com

99 Protection, monitoring and control Protection Protection relay selection Easergy Sepam and Easergy MiCOM Easergy Sepam series 60 Easergy Sepam series 80 Easergy Micom series 30 Function PE90488 PE90512 PE90622 Phase and earth-fault Feeder With directional With line differential With distance Voltage Voltage and frequency Phase and earth-fault Transformer With transformer differential Phase and earth-fault Motor With voltage With machine differential Phase and earth-fault Generator With directional With machine differential Busbar With busbar differential Capacitor bank Sensors CT (1 or 5 A) or LPCT VT CT (1 or 5 A) or LPCT VT CT (1 or 5 A) VT Display Standard UMI Remote UM Mimic based UMI Standard UMI Remote UM Mimic based UMI Standard UMI Remote UMI Mimic based UMI Other characteristics Removable S/W cartridge Removable S/W cartridge Bay controller High firmware/hardware variability Input/Output (up to) 28/16 42/23 80/45 I/O terminals Screw type Ring lug Screw type Ring lug Screw type Ring lug Temp. sensors (up to) 8 to 16 8 to Communication protocol Logic equations Modbus RTU IEC DNP3 Modbus TCP/IP IEC with GOOSE RSTP Comprehensive logic equations Modbus RTU IEC DNP3 Modbus TCP/IP IEC with GOOSE RSTP Control logic by ladder diagram Modbus RTU IEC /103 DNP3 IEC with GOOSE RSTP/SHP/DHP PRP Comprehensive logic equations Standards UL, CSA, EAC, ATEX IEC SIL2, UL, CSA, EAC, ATEX IEC, EAC, ATEX schneider-electric.com Premset Catalog 99

100 Protection, monitoring and control Fault passage indicators Flair 21D, 22D and 23DM Flair 21D, 22D, 23DM is a family of DIN format fault passage indicators. They are small in size, self-powered and adapt automatically to the network. These devices use cutting-edge technology to detect earth faults on underground MV networks with isolated, resistor-earthed or directly earthed neutral and overcurrents on all networks. Self-powered, the fault current passage detection and indication system operates continuously Adjustment-free, they are immediately operational (numerous manual adjustments are however possible) Compact, their DIN format easily fi ts in MV cubicles Smart, they offer an ammeter/digital maximeter function Comprehensive, the Flair 23DM version incorporates a highly sophisticated voltage presence/absence relay function with RJ45 Modbus communication. Applications and main features The Flair range increases your power availability by providing indicators suitable for fault locating and MV network load management. Indication of phase-phase and phase-earth faults Display of settings Indication of the faulty phase Display of the load current including peak demand and frequency Fault passage indication and voltage detection combination (Flair 23DM) RJ45 communication (Flair 23DM only). These fault passage indicators are reliable and easy to use. Automatic setting on the site Fault indication with LED or outdoor lamp 15-year battery life for Flair 22D More accurate fault detection if Flair 22D or 23DM is connected to voltage presence indication system (VPIS) voltage output Can be factory-mounted in Premset cubicles or added on the site Easy on-site addition without removing MV cables using split-type current sensor. Fault detection functions Overcurrent detection Automatic mode for adjustment-free calibration of detection thresholds Manual mode for special override settings: - Flair 21D: 4 detection thresholds from 200 A to 800 A, in 200 A increments, selectable via microswitches - Flair 22D and Flair 23DM: 8 detection thresholds from 100 A to 800 A, in 50 A increments, confi gurable via the front panel keypad. Fault acknowledge time: - Flair 21D: 60 ms - Flair 22D and Flair 23DM (confi gurable via the front panel keypad) - from 40 to 100 ms in 20 ms increments - from 100 to 300 ms in 50 ms increments. Earth fault detection The detector checks the 3 phases for current variations (di/dt). A time delay of 70 s is applied for fault confi rmation by the upstream protective device. Automatic mode for adjustment-free calibration of detection thresholds Manual mode for special override settings: - Flair 21D: 6 detection thresholds from 40 to 160 A, via microswitches - Flair 22D and Flair 23DM (confi gurable via the front panel keypad): - Type A from 20 to 200 A, in 10 A increments - Type B from 5 to 30 A in 5 A increments and 30 to 200 A in 10 A. Inrush function: prevents unnecessary detection in the event of load switch-on. Incorporates a 3 s time delay for fault fi ltering at network power up. The Inrush function can be disabled via confi guration on Flair 22D and 23DM. 100 Premset Catalog schneider-electric.com

101 Protection, monitoring and control Fault passage indicators Flair 21D, 22D and 23DM Earth fault sensitivity as low as 5 A Display of settings and faulty phase Automatic reset Fault indication function Signalling PE57783 As soon as a fault is confirmed, the indication device is activated. Fault indication via a red LED on the front panel Indication of the faulty phase (earth fault) on LCD display Optional remoting of indication to external fl ashing lamp Activation of a contact for retransmission to the SCADA system Indication reset PE57784 Flair 21D Automatic resetting upon load current recovery or on voltage return if VPIS-VO option present (confi gurable time on Flair22D, Flair23DM) Manual reset via front panel button Reset via external Reset input Reset by time delay: fi xed (4 hr) for Flair 21D and adjustable using front panel keypad (1 hr to 24 hr) for Flair 22D and Flair 23DM. Reset via the communication (Flair 23DM) Flair 22D EMS58355 Flair 23DM schneider-electric.com Premset Catalog 101

102 Protection, monitoring and control Fault passage indicators Flair 21D, 22D and 23DM DE58715 L1 L2 L3 Sensors The Flair 21D, 22D, 23DM range uses an integrated detection system composed of indicators and dedicated CTs. Integrated sensors are normally placed around the bushings. Split CTs can be placed around cables for retrofi t purposes. Esc A Clear, comprehensive display Test Reset I max. Easergy Flair 22D EMS58352 Display principle The load current is displayed continuously When a fault is detected, the faulty phase is indicated Use the buttons on the front panel to scroll through settings and measurements. 21D 22D 23DM Power supply Self-powered p p p Dual-powered p (1) p Detection Overcurrent p p p Earth-fault p p p Display Ammeter p p p (4 digit LCD) Maximeter p p p Options SCADA interface (relay) p p p External lamp p p p External reset p p Extended setting (keypad) p p Communication 2-voltage output relays p Serial communication port p (1) By lithium battery Flair Connection diagrams Characteristics per product DM Flair 21D Flair 22D Flair 23DM Reset Reset Reset L3 L2 L1 Indication L3 L2 L1 Indication L3 L2 L1 SCADA Reset Indication VPIS-VO option VPIS-VO option Voltage relays + - Com RS485 Model Description Fault passage indicator with single power supply (self-powered) Flair 21D Detector with autonomous power supply External indicator lamp output powered by battery (BVP) Fault passage indicator with dual power supply Flair 22D Detector with autonomous power supply and lithium battery External indicator lamp output powered by the Flair (BVE) Interface with VPIS-VO possible to confirm the fault by voltage absence Service life: 15 years Fault passage indicator with dual power supply and voltage presence/absence Flair 23DM Detector with Vdc external and autonomous power supply External indicator lamp output powered by the Flair (BVE) Voltage presence and absence detector (same as for VD23) Interface with VPIS-VO needed for the voltage presence Communication on an RS485 serial link with Modbus protocol with access to states and measurements and remote parameter-setting Standard applications Flair 21D Maintenance-free, adjustment-free fault detector Flair 22D Fault detector for networks with very low load current (< 2 A) with possibility of manual adjustments. Flair 23DM Adapted to Feeder Automation. Forwarding of current measurement, fault passage indication and voltage outage information to the SCADA via a serial communication port. Combination fault passage indicator and voltage detector, ideal for use with an Automatic Transfer System. 102 Premset Catalog schneider-electric.com

103 Protection, monitoring and control Voltage indicator and relay VPIS and VDS PE56366 Voltage presence indicators VPIS A voltage presence indicating device can be integrated in all the functional units, either on the cable or busbar side. It can be used to check whether or not a voltage is present across the cables. Two devices are available: VPIS: Voltage Presence Indicator System, as defi ned by standard IEC VDS: Voltage Detecting System, as defi ned by standard IEC PM The VPIS can be fi tted with a voltage output (VPIS-VO) dedicated to various voltage detection applications such as automatic transfer switches, voltage absence or presence contacts, live-cable earthing switch lockout. Voltage sensors A voltage sensor is integrated in all the functional units. It provides a signal with an accuracy of 5% to the VPIS through a 30 pf capacitive divider. The sensor is integrated in the tightening cap used to fi x the busbar or cable connections. The voltage can be detected either on the cable side or the busbar side. Voltage presence sensors Voltage presence sensors on busbars or cables Phase concordance unit This unit is used to check phase concordance. PE56830 Phase concordance unit schneider-electric.com Premset Catalog 103

104 Protection, monitoring and control Voltage indicator and relay VD23 voltage relay The VD23 is a voltage detecting system for automatic transfer system or interlock applications. Various combinations: Presence or absence voltage relay Zero sequence voltage relay Phase-to-neutral or phase-to-phase voltage Phase selection. Easy to install: Compact 96 x 48 mm DIN format Terminal connection for VPIS-VO No need for HV transformer Hot installation Auto-adaptation of nominal voltage. Optional communication port and fault detector (Flair 23DM) Features The VD23 is a compact voltage relay for 3 kv to 36 kv, 50/60 Hz medium voltage networks. It is associated with a capacitive divider and a VPIS-VO. 2 output relays based on 2 functional modes: - R1 = Voltage presence (typically used for automatic transfer switching) - R2 = Voltage absence (typically used for interlocking of earthing switch). Thresholds can be set as a percent of phase-to-neutral voltage (V), phase-to-phase voltage (U) or residual voltage (VO) All combinations of voltage conditions are possible: - 3 phases and residual: V1+V2+V3+VO - 3 phases: V1+V2+V3 or U12+U13+U23 - Single phase: Vo, V1, V2, V3, U12, U13 or U23 Output is a tripping order via two output relays with a normal or inverse active position Signalling and tripping outputs may be set with a delay. Display principle Voltage value (% of Un) of L1, L2 and L3 shown on the display Voltage presence/absence indication via LED Settings by front pushbuttons and LCD thresholds, delays and smart parameters display of all settings on LCD. Auto-adaptation of the nominal system voltage Check on voltage status. PE57787 Advanced settings All the combinations can be set with microswitches on the rear of the device. The use of two relays provides safety backup operation for each combination 6 microswitches: 1. Ph-N voltage(v) / Ph-Ph voltage(u) VD Direct / inverse action on output relays 3. Phase 1 used / not used 4. Phase 2 used / not used 5. Phase 3 used / not used 6. Residual voltage used / not used DM L1 L2 L3 VD23 Wiring (with VPIS-VO) All the combinations can be set with microswitches on the rear of the device. The use of two relays provides safety backup operation for each combination. VPIS-VO Voltage absence Voltage presence Vdc 104 Premset Catalog schneider-electric.com

105 Protection, monitoring and control Live cable interlock Functions DM Technical data Auxiliary power: VDC VAC / VDC Key types: - Ronis - Profalux VPIS-VO LCI Electric Device Ø LCI Electronic Device AC/DC supply The live cable interlock function is an electrical interlock helping to prevent the operator from closing the earthing switch on live cables. Even if all the earthing switches integrated in Premset core units have full making capacity performance, it may be useful to avoid creating intempestive faults by inadvertently earthing live cables. Principle The system is composed of: A mechanical locking assembly acting directly on the line / earth selector, including an override key that can be used to bypass the locking device An undervoltage coil for high failsafe operation of the mechanical lockout system (see MN, page 75) A dedicated electronic auxiliary-powered voltage relay (ESL) fi tted with an auxiliary contact for remote indication of locked position A VPIS indicator on the cable side, with a voltage output (VPIS-VO), to detect and send the voltage signal to the relay. Operation Normal case : the system is powered by auxiliary power. It is then impossible to move the selector from line to earth, as long as voltage is detected on the cable by the VPIS. In case of auxiliary power loss, cables live or not, a failsafe features blocks the system so the selector cannot be operated. Override is possible only by unlocking the system with key or when auxiliary power is restored. Technical data Auxiliary power VDC: ESL100 A VAC / VDC: ESL100 E Key types Tubular Flat Undervoltage coil schneider-electric.com Premset Catalog 105

106 Protection, monitoring and control Thermal monitoring Easergy T110: wireless thermal sensors * Key benefits Battery free Wireless communications High performances In contact measuring point Easy installation Compact footprint Remote monitoring and alarming Continuous thermal monitoring The power connections in the Medium Voltage products are one of the most critical points of the substations especially for those made on site like: MV Cable connections Bus bar connections Withdrawable CB connections Loose and faulty connections cause an increase of resistance in localized points that will lead to thermal runaway until the complete failure of the connections. Preventive maintenance can be complicated in severe operating conditions also due to limited accessibility and visibility of the contacts. The continuous thermal monitoring is the most appropriate way to early detect a compromised connection. DM SCADA BMS Com X Easergy TH110 thermal sensor Easergy TH110 is part of the new generation of wireless smart sensors ensuring the continuous thermal monitoring of all the critical connections made on field allowing to: Prevent unscheduled downtimes Increase operators and equipments safety Optimize maintenance with predictive information Nearby HMI Local HMI SMD GSM Facility Hero Thanks to its very compact footprint and its wireless communication, Easergy TH110 allows an easy and widespread installation in every possible critical points without impacting the performance of the MV Switchgears. By using Zigbee Green Power communication protocol, Easergy Th110 ensure a reliable and robust communication that can be used to create interoperable solutions evolving in the Industrial Internet of Things (IIoT) age. Easergy TH110 is self powered by the network current and it can ensure high performances providing accurate thermal monitoring being in direct contact with the measured point. TH110 TH110 Wireless Smart Sensors Substation monitoring device Easergy TH110 is connected to the Substation Monitoring Device (SMD) that harvest the data for local signaling, data analyses and nearby display. Specific monitoring algorithms allow to detect drifts from the threshold based on the specifi c installation characteristics also in regards of the variable loads or abnormal behaviors coming from phases comparison. The remote monitoring and alarming ensure full peace of mind thanks to remote connection for SCADA or Services, access to Cloud-based Apps and digital services and alarming through SMS or Facility Hero mobile App. Characteristics Power supply Minimum activation current Self powered. Energy harvested from power circuit. 5 A Accuracy +/- 1 C Range -25 C / +115 C Wireless communication ZigBee Green Power 2,4 GHz Dimension - Weight 31 x 31 x 13 mm - 15 g 106 Premset Catalog schneider-electric.com

107 Protection, monitoring and control Integrated measurement AMP 21D ammeter Traditionally, three analogue dial-type ammeters were installed on MV feeders with a costly and bulky TC to power them. These devices had poor accuracy (cl. 1.5) and no maximeters to provide feedback on the maximum load Now, with the AMP 21D digital ammeter, all feeders can be equipped with small CTs that provide accurate measurements and a maximeter function, all at a lower price The AMP 21D is self-powered to display currents continuously Its compact DIN format easily fi ts in Premset MV cubicles Versatile, it displays phase current and maximum current Functions The Easergy Amp 21D is an ammeter dedicated to the display of the load current on Medium Voltage networks. It is particularly suited to network load management applications. Display of the 3 phase currents: I1, I2, I3 (range: 3 A to 800 A) Display of the 3 phase current maximums: M1, M2, M3 (range: 3 A to 800 A) Display principle Load currents are displayed by default, with continuous scrolling of L1, then L2, then L3. The maximeter is displayed by pressing a dedicated pushbutton, with continuous scrolling of maximum currents M1, then M2, then M3. The maximums are reset by pressing a combination of two pushbuttons Design Small enclosure DIN format: 93 x 45 mm Secured, extraction-proof mounting Terminal connections PE57786 Technical data Frequency 50 Hz and 60 Hz Load current Minimum current 3 A AMP 21D Measurement Range Phase current 3 to 800 A Accuracy (I < 630 A) ± 3%, ± 2 A DM Connection diagram L1 L2 Reset of maximeter Manual from device Yes Power supply Self powered From the current sensors Battery I load > 3 A No L3 Auxiliary supply No AMP 21D Display Display Current per phase Maximeter current per phase 4 digits LCD Yes (resolution 1 A) Yes Sensors Phase CTs 3 ring or split core CT (1) Other Test Yes (1) CT selection refer to page 79 schneider-electric.com Premset Catalog 107

108 Protection, monitoring and control Integrated measurement PM5000 series Power Meter PB PowerLogic PM5000 series help you: Reduce energy costs Simplify installation Improve continuity of service for optimal management of your electrical installation and higher productivity PM5000 series Power Meter Applications and main features The PowerLogic PM5000 power meter is the ideal fi t for cost management applications. It provides the measurement capabilities needed to allocate energy usage, perform tenant metering and sub-billing, pin-point energy savings, optimize equipment effi ciency and utilization, and perform a high level assessment of the power quality of the electrical network. In a single 96 x 96 mm unit, with a graphical display, (plus optional remote display) all three phases, neutral and ground can be monitored simultaneously. Highly accurate devices with 3rd party certifi cation. The Power Meter series 5000 is available in multiple versions including: PM5100, basic version with pulse output, class 0.5S accuracy PM5110, RS485 port with Modbus communication, class 0.5S accuracy PM5340, multi-tariff, data logging, Ethernet communication, class 0.5S accuracy PM5560, multi-tariff, data logging, WAGES metering, Gateway, class 0.2S accuracy, simultaneous communication via Modbus TCP and BACnet/IP Characteristics * High-accuracy energy metering: IEC Class 0.5S or Class 0.2S Multiple communication options: RS485, Ethernet or both Dual Ethernet ports (PM5560 models) to daisy chain meters together - less wiring, simpler installation Ethernet-to-serial gateway functionality (PM5560) Protocol options include Modbus RTU, Modbus TCP and BACnet/IP Data logging (PM5340, PM5560 models) Multiple tariffs (PM5340, PM5560 models) Complete WAGES monitoring with 4 Digital Inputs & 2 Digital Outputs Onboard web pages (PM5560 models) for viewing real-time and logged information Bright, anti-glare graphical display with intuitive menu-driven navigation 108 Premset Catalog schneider-electric.com

109 Protection, monitoring and control Integrated measurement PM8000 series Power Quality Meter PowerLogic PM8000 series: Compact, high-performance meters for cost and network management applications on feeders and critical loads. Detailed PQ compliance reporting, and expert-level root-cause analytics. Power monitoring, logging, and forecasting to help ensure your electrical system stays within safe operating tolerances, avoiding the risk of overloads, unbalances, or high peak demand PM8000 series Power Quality Meter Applications and main features The PowerLogic PM8000 series meter is a highly accurate, extremely reliable power and energy meter with unmatched fl exibility and usability. The meter combines accurate 3-phase energy and power measurements with data logging, power quality analysis, alarming and I/O capabilities not typically available in such a compact meter. The PM8000 series meters are compliant with stringent international standards that guarantee their metering accuracy and power quality measurements. Ideal for industrial and critical power installations that are responsible for maintaining the operation and profi tability of a facility. The PM8000 series is available in the versions: PM8240, panel mount, integrated display PM8244, DIN rail mount, remote display PB Characteristics High-accuracy energy metering: IEC Class 0.2S Time synchronization Multi-tariff support WAGES metering support PQ compliance monitoring: IEC class S, IEC 62586, EN 50160, IEEE 519 PQ analysis capabilities: Dip & swell detection, waveform capture, disturbance direction detection, trending & forecasting Protocols: ION, Modbus, DNP3, IEC Ports: RS-485, dual-port Ethernet, Ethernet-to-serial gateway Graphical, color display Onboard, customizable web pages Modular I/O extension modules. schneider-electric.com Premset Catalog 109

110 Protection, monitoring and control Control SC110: electrical operation auxiliaries The SC110 is an intelligent electronic device designed to control and monitor all the components involved in the remote control of core units. It integrates all the necessary functions for reliable remote control: Electrical interlocking Remote control supervision Front panel interface for local operation Built-in Modbus communication and Plug and play design makes the SC110 and the remote control facility: - easy to use - easy to upgrade. SC110 universal intelligent controller SC110 is a compact device with digital inputs and outputs to monitor all the components associated with the electrical operation of the core unit: MCH, MX, XF, auxiliary contacts. It can be associated with a control panel (SC-MI). Switchgear control functions Coil and motor operation Information on core unit status: main switch, earthing switch, lever insertion Built-in electrical interlocks: anti-pumping and anti-reflex functions External interlocking feature Lockout of electrical operation after tripping (option) Modbus communication for remote control via data transmission Switchgear monitoring PM Diagnosis information: motor consumption Core unit auxiliary contacts status Logging of time-stamped events Modbus communication for remote indication of monitoring information PM SC110A 3 RJ45 Modbus plugs SC110 types SC110-A SC110-E Vdc p 110 Vdc/Vac - 240Vac/250Vdc p Network communication p p SC-MI control panel SC-MI control panels SC-MI 10 SC-MI 20 On/Off pushbuttons p p Remote/local switch p DM Modbus SC110 MCH MX XF Auxiliary contacts The SC110 is installed in the Low Voltage cabinet of the functional unit. It controls and monitors all the devices needed for electrical operation: MCH, MX, XF, auxiliary contacts. 110 Premset Catalog schneider-electric.com

111 Protection, monitoring and control Control Architecture of feeder automation Schneider Electric offers you a complete solution, including: The Easergy R200 telecontrol interface Premset switchgear that can be easily adapted for telecontrol The SCADA and DMS system Premset range, more than ready Premset switchgear is suited to telecontrol thanks to options such as: LV control cabinet including an R200 RTU Motorised operating mechanism Auxiliary fault and position indication contacts Current sensors for fault detection Continuity of service supervised by an overall telecontrol solution DM100010EN HV/MV Substation automation Feeder automation DM Network control centre Easergy R200 Easergy R200 Premset Premset Premset Communication network: radio, PSTN, GSM/ GPRS, Ethernet Communication network MV ring Premset Premset Premset Easergy R200 PE58301 Telvent DMS system schneider-electric.com Premset Catalog 111

112 Protection, monitoring and control Control Easergy R200: control unit PE57570p Easergy R200 is a Remote Terminal Unit (RTU) intended for typical remote management applications in the Energy industry and for MV infrastructures in general. Easergy R200: an interface designed for telecontrol of MV networks The Easergy R200 plug and play RTU integrates all the functional units necessary for remote supervision and control of an MV switchboard cubicle: Transmission of switch open/close orders Exchanges with the control centre. Easergy R200 is of proven reliability and availability, ready to ensure switchgear operation at any time. It is simple to set up and to operate. Communication Easergy R200 can manage both serial type and IP protocols. It is thus possible to mix serial and IP transmission media in a given application. Communication possibilities are continuously evolving to keep pace with your needs: IEC and IEC protocols DNP3 serial and TCP protocols Modbus serial and TCP protocols Other proprietary protocols An extensive choice of integrated modems and interfaces: RS232/485 serial interface GSM/GPRS modem 3G Modem Voice modem (PSTN) FSK radio modem FFSK radio modem Ethernet port Local control in SCADA Easergy R200 incorporates a Web data server in HTML page form for data confi guration and monitoring. All that is needed to log on is a PC with a Web browser. Remote access is possible via GSM, GPRS, Ethernet or PSTN transmission networks and can be implemented in parallel from the remote control centre. Thanks to this remote access and its capability to send s and SMSs, the R200 offers you a cost-effective solution to monitor your MV substation without a SCADA system. The embedded Web server allows local monitoring of the substation. 112 Premset Catalog schneider-electric.com

113 Protection, monitoring and control Control Easergy R200: control unit Built-in solutions for protecting, monitoring and controlling your installation. Energy availability Measurement Remote fault detection Remote control and protection devices. Easy to use Compact design with built-in devices - no engineering required Scalable with just enough dedicated solutions from monitoring to remote control Robust devices designed for harsh environments Easy and safe plug and play connection Open to standard protocols, ensuring easy SCADA connection R200 Premset PM100016_Former _??? PE57570p schneider-electric.com Premset Catalog 113

114 Protection, monitoring and control Control ATS100: automatic transfert system An MV power supply interruption is unacceptable, especially in critical applications. The Premset system therefore proposes an automatic source transfer solution. Source transfer The ATS100 drives automatic transfer from the normal MV source to the back-up source in order to keep supplying the MV substation in case of failure of the normal source. ATS100 can drive either Load Break Switch or Circuit Breaker. There are 3 types of ATS100 depending of single line diagram and sources. ATS100-ACO: 2 line incomers DM L1 and L2 can be either normal or backup source. Upon loss of Normal source, Backup source will automatically supply the substation. When Normal source recover there are 3 possibilities depending of the confi guration : Self-return : The Normal source will automatically supply the substation No-return : Only a manual operation will be possible for Line to supply again the substation. Auto-return : The Normal source will automatically supply the substation only in case of loss of the back-up sources. ATS100 L1 ATS100-ACO: 2 line incomers L1 L2 G L2 ATS100-GEN (*): 1 line and 1 generator incomers L1 and L2 can be either Line or Generator source. Only the Line can be the Normal source. Upon loss of it, Generator source will automatically be started and the supply the substation. When Line source recover there are 3 possibilities depending of the confi guration: Self-return : The Line source will automatically supply the substation and generator will be shut down No-return : Only a manual operation will be possible for Line to supply again the substation Auto-return : The Line source will automatically supply the substation only in case of loss of the generator sources ATS100-BTA : 2 line incomers with bus tie ATS100-GEN: 1 line and 1 generator incomers Normal situation is L1 and L2 closed and Bus Tie open. In case of loss of one of the lines, the bus tie is automatically closed to recover the supply of the substation. When both lines are back, depending of the confi guration, the Normal situation is automatically recovered or not. L1 L2 ATS100-BTA : 2 line incomers with bus tie * Please consult us for availability 114 Premset Catalog schneider-electric.com

115 Protection, monitoring and control Control ATS100: automatic transfert system Characteristics Switch response time Parallel coupling Load shedding Time delay before changing source 0.5s to 3s Coonfi gurable to avoid black-out when restoring normal situation Confi gurable to adapt load to the capacity of the generator or to restart loads in sequence after blackout. Confi gurable up to 120s Time delay before recovering normal situation Configurable up to 30mn Remote communication WebServer Ethernet, GSM, GPRS, or 3G communication with: IEC and IEC protocols DNP3 serial and TCP protocols Modbus serial and TCP protocols Easergy ATS100 incorporates a Web data server in HTML page form for data confi guration and monitoring. All that is needed to log on is a PC with a Web browser. DM L1 L2 Typical diagram 2 VPIS-VOs Voltage sensor: dedicated version of VPIS with Voltage Output signal. Flair 23DM Flair 23DM 2 Flair 23DMs Voltage detector + Fault Passage Indicator: a relay is activated when a loss of voltage is detected from the VPIS voltage output signal. If a fault current is detected, the Automatic Transfer System is locked out in order to avoid closing the healthy line on the fault. SC110 SC110 ATS100 1 ATS100 + switch or CB function Based on inputs coming from the Flair 23DMs, the decision is made to switch from one line to the other. M Field bus M SCADA, BMS Communication facilities may be added Communication to SCADA or BMS (optional) Web Server: confi guration, diagnostics, alar ms, logs schneider-electric.com Premset Catalog 115

116 Protection, monitoring and control Control PS100: high-availability power supply Backup solution for MV switchgear power needs in the event of micro outages and power interruptions. Easy maintenance with only one battery Remote battery monitoring High level of insulation to protect the electronic devices in harsh MV environments End-of-life alarm possible via Modbus communication Compliant with standards IEC (10 kv level). PS100 backup power supply for MV substations Applications The power supply unit supplies backup operating power for: MV switchgear motor mechanisms and circuit breaker coils Transmission equipment (e.g. radio) Control units such as RTU (R200) or Automatic Transfer System (ATS100) Protection relays, Fault Passage Indicators and other electronic devices High availabilty power supply PM A battery provides uninterrupted operation of the whole substation in the event of loss of the main supply. The backup power supply unit: Includes a regulated and temperature-compensated charger Stops the battery before deep discharge Carries out a battery check every 12 hours Measures battery ageing Forwards monitoring information via a Modbus communication port and output relays PS100 PS100 benefi ts Only one battery Traditional backup power supplies require a set of 2 or 4 batteries to produce 24 V or 48 V, with complicated replacement and adjustment of the battery pack. The PS100 needs only one battery, simplifying replacement. The battery is a standard sealed lead-acid 12 V battery with a 10-years service. It can be purchased easily, anywhere in the world. Improved availability of MV substations The PS100 is designed to ride through power network interruptions of up to 48 hours. It is associated with a battery selected to meet the required backup time. For example, a 38 Ah battery provides 12 hours of backup time to a Premset switchboard including 4 Sepam units. The PS100 protects and optimises the battery with state-of-the-art monitoring. A Modbus communication port forwards monitoring data to allow optimised maintenance operations. 116 Premset Catalog schneider-electric.com

117 Protection, monitoring and control Control PS100: high-availability power supply DM Battery + PS100 Additional energy backup The PS100 stops supplying power and reserves an additional energy backup to restart the installation after an extended power interruption. The additional energy backup can be enabled with a local pushbutton to provide energy for restarting the protection relays and operating the MV switchgear. Withstands severe substation environments The PS100 includes 10 kv insulation, electronic protection against overvoltage and overloads, and automatic restart after a fault. Main features DIN rail mounting for easy integration in any LV cabinet 2 power supply outputs 12 Vdc - 18 W continuous W 20 s (for modem, radio, RTU) 48 Vdc or 24 Vdc W /1 minute (for switchgear operating mechanism motors) and 90 W / continuous for protection relays, electronic devices RJ45 Modbus communication port 2 output relays (AC supply ON, Battery ON) Diagnosis with LEDs 1 sealed lead-acid 12 V battery with a 10-years service life (from 24 Ah to 40 Ah) Power supply paralleling available with a 2nd PS C to +70 C operating temperature Range PS100-48V PS100-24V Bat24AH Bat38AH 48 Vdc power supply and battery charger 24 Vdc power supply and battery charger 24 Ah long life battery 38 Ah long life battery schneider-electric.com Premset Catalog 117

118 Connections 118 Premset Catalog schneider-electric.com

119 Connections Busbar and cable arrangements 120 Cable connections 121 Network cable testing and diagnosis device 124 Schneider Electric services 126 Facility Hero 128 schneider-electric.com Premset Catalog 119

120 Connections Busbar and cable arrangements SSIS connections with shielded solid insulation, eliminating all electric fields in open air. Flat and smooth interface between connections, allowing flexibility and misalignment in any direction: easier floor installation Only one cable connection set, used everywhere: many possibilities for cable entry arrangements Universal system of power connections The Premset system is based on a set of common elements, used throughout the system: 2 types of bar elements, used to make up the busbar system as well as risers and downstream connections between cubicles. One set of 3 connections for cables, used in various directions: front, rear, bottom, top The connection interface between these elements is always the same (Schneider Electric patented design), allowing a wide variety of arrangements. For example, the set of cable connections can be fitted in different directions to implement various cable entry arrangements: front bottom, top rear, bottom rear, direct connection to busbars, cable in cable out. PM PM PM DM PM PM Busbars with shielded solid insulation PM Cable connections with shielded solid insulation 120 Premset Catalog schneider-electric.com

121 Connections Cable connections PM Only one type of bushing to simplify installation, but various arrangements of connections to fit any application. Large choice of cable box and bottom compartment dimensions. LV cabinet Cable test Top connection Core unit Bottom connection Bottom compartment Bottom compartment The bottom compartment is the lower part of Premset cubicles. It has been designed separately from the rest of the cubicle to offer different versions. It comes in two different heights to match the space required for cable bending and switchgear installation: Standard height, for cable connections at a height of 700 mm. Low-height version for cable connections at a height of 500 mm, allowing installation of switchgear in rooms with low ceilings (total height of switchgear as low as 1350 mm, depending on LV cabinet dimensions). For higher installations, raising plinths can be fitted as accessories, with two different heights. Cable connections Cable boxes are available in 2 different depths to meet the needs of various types of installations: number of cables, type of connections, bending radius of cables, surge arresters. Cable boxes can be interlocked with main and earthing switches (see core unit pages) and can be fitted with two transparent windows (not compatible with internal arc performance). Cable bushings are standardised Type "C" (EN50181), M16 screw type bushings as defined by standard IEC 60137, in order to simplify the choice and installation of connections. Cable connections are always horizontally aligned, 700 or 500 mm high depending on height of the bottom compartment (please refer to dimension drawings in the technical appendix). Compatible cable connections 1 cable per phase D06H DM cables per phase DM schneider-electric.com Premset Catalog 121

122 Connections Cable connections Compatible cable connections except for I12H and D12H Check the cables that you are using are compatible with the recommendations supplied in the catalog. Otherwise use other compatible cables with these recommendations. Supplier Performance Cr. section (mm²) Euromold (Nexans) NKT Cables GmbH Südkabel Tyco / Raychem (insulated adapter) 3M Up to 12 kv, 630 A Up to 17,5 kv, 630 A Up to 12 kv, 630 A Up to 17,5 kv, 630 A Up to 12 kv, 630 A Up to 17,5 kv, 630 A Up to 12 kv, 630 A Up to 17,5 kv, 630 A Up to 12 kv, 630 A Up to 17,5kV, 630 A Reference Type 2 c/p + Surge arrester LB E 2 cables / phase (2 c/p) TB T ² TB T TB T ² + VRU1 + Surge arrester + VRU TB + 400PB-XSA T + S ² ² TB + 300SA T + S ² TB PB-XSA T + S ² ² K400LB E ² K400TB T K430TB T ² K440TB T K400TB + K400PB-XSA T + S ² ² K430TB + 300SA T + S ² K440 TB + K400 PB-XSA T + S ² ² CB T CB CSA12 T + S ² CB T CB CSA24 T + S ² SET12 T SEHDT13 T ³ ² SEHDT13 + MUT13 T + S ² ² SET24 T SEHDT23 T ³ ² SEHDT23 + MUT23 T + S ² ² RICS-5113 T RICS-5123 T RICS-5133 T 300 RICS-5143 T RICS-5139 T + S 300 RICS-5149 T + S RICS-5123 T RICS-5133 T RICS-5143 T RICS-5139 T + S RICS-5149 T + S EE T EE T ² EE MUT23 T + S ² ² EE T EE T EE MUT23 T + S ² ² (1) For 2 cables/phase, 2 cables/phase + Surge arrester, 2 cables/phase + VRU1, please consult Schneider Electric (2) Need deeper cable (500mm) compartment door (3) Need deeper cable (500mm) compartment door for internal arc with standard version E: Elbow connector T: T connector T + S = T connector + surge arrester 122 Premset Catalog schneider-electric.com

123 Connections Cable connections Compatible cable connections for I12H and D12H Check the cables that you are using are compatible with the recommendations supplied in the catalog. Otherwise use other compatible cables with these recommendations. Supplier Performance Cr. section (mm²) Euromold (Nexans) NKT Cables GmbH Südkabel Tyco / Raychem (insulated adapter) 3M Up to 12 kv, 630 A Up to 17,5 kv, 630 A Up to 12 kv, 630 A Up to 17,5 kv, 630 A Up to 12 kv, 630 A Up to 17,5 kv, 630 A Up to 12 kv, 630 A Up to 17,5 kv, 630 A Up to 12 kv, 630 A Up to 17,5kV, 630 A Reference Type 4 c/p + Surge arrester LB E (1) For more or less than 2 cables/phase, please consult Schneider Electric (2) Need deeper cable compartment door: 500mm (450mm for I12H and D12H) (3) Need deeper cable compartment door 500mm (450mm for I12H and D12H) for internal arc withstand version 4 cables / phase (4 c/p) TB + 400TB T ² TB + 430TB T TB + 440TB T ² + VRU1 + Surge arrester + VRU TB + 400TB + 400PB-XSA T + S ² ² TB + 430TB + 300SA T + S ² TB + 440TB PB-XSA T + S ² ² K400LB+K400LB E K400TB+K400TB T ² K430TBK430TB T K440TB+K440TB T ² K400TB+K400TB + K400PB-XSA T + S ² ² K430TB+K430TB + 300SA T + S ² K440 TB+K440 TB + K400 PB-XSA T + S ² ² CB CB T CB CB CSA12 T + S ² CB CB T CB CB CSA24 T + S ² SET12+SET12 T SEHDT13+SEHDT13 T ³ ² SEHDT13 +SEHDT13 + MUT13 T + S ² ² SET24+SET24 T SEHDT23+SEHDT23 T ³ ² SEHDT23+SEHDT23 + MUT23 T + S ² ² RICS RICS-5113 T RICS RICS-5123 T RICS RICS-5133 T 300 RICS RICS-5143 T RICS RICS-5139 T + S 300 RICS RICS-5149 T + S RICS RICS-5123 T RICS RICS-5133 T RICS RICS-5143 T RICS RICS-5139 T + S RICS RICS-5149 T + S EE EE T EE EE T ² EE EE MUT23 T + S ² ² EE T EE T ² EE EE MUT23 T + S ² ² E: Elbow connector T: T connector T + S = T connector + surge arrester schneider-electric.com Premset Catalog 123

124 Connections Network cable testing and diagnosis device Premset offers an original primary circuit arrangement allowing direct access to cable conductors without operating the main switches or dismantling the cables connections. Combined with a dedicated cable test device, it provides high operator safety during cable testing and diagnosis. Cable testing and cable diagnosis Medium voltage cable testing is a demanding task that leaves no room for error Work is carried out on the main circuit with a high-voltage test bench Earthing is removed during testing Access to the main circuit for test connections may require access to the cable box and dismantling of cable termination insulation Procedures must be followed strictly to ensure the safety of personnel Cable connections must be properly reassembled to restore full insulation PM Intuitive and easy cable access with Premset Premset switchboards can be fitted with a dedicated cable testing device that greatly increases safety during cable testing Cable testing can be carried out without accessing the cable box (cables remain connected) and without touching the cable terminations The test device can be connected from the front of the switchboard, prior to removing the earth link Earth link removal is the last operation to be carried out, using a special earthing bar disconnection system, without any operation of the main switching device or main earthing switch Earth link removal featuring full failsafe interlocking, i.e. the earth link can be opened only if the main earthing switch is closed (cable earthed) and the main earthing switch can be opened only if the earthing link is closed Test bench connections are delivered separately. They can also be adapted locally to any specific test set. 124 Premset Catalog schneider-electric.com

125 Connections Network cable testing and diagnosis device The cable testing device can be used on both ends of cable to be tested, in order to isolate completely the cable section from the network. DM PM Safe and fully interlocked device Double isolating gap during testing Direct access to cable conductor without operating the main switch Cable Technical characteristics Cable testing device can be used for various testing and diagnosis purposes: DC tests up to 36 kv DC x 15 min Very low frequency testing from 0.1 Hz up to 20 kv x 30 min (sinusoidal signal), and 28 kv x 30 min for cos2 signal. 50/60 Hz dielectric tests up to 14 kv x 1 min Tan Delta diagnosis: power dissipation 18 kv. Performance characteristics have been validated in accordance with standard IEC , edition 2 schneider-electric.com Premset Catalog 125

126 Connections Schneider Electric Services Peace of mind throughout your installation life cycle DM How can you cut costs and improve performance at the same time? When it comes to your electrical distribution infrastructure, the answer is straight-forward - get professional expertise. Life cycle services Plan What are my options? Install How do I install and commission? Plan Schneider Electric helps you to plan the full design and execution of your solution, looking at securing your process and optimizing your time: Technical feasibility studies: Accompany customer to design solution in his given environment Preliminary design: Accelerate turnround time to come to a final solution design Install Schneider Electric will help you to install efficient, reliable and safe solutions based on your plans. Project management: Designed to help you complete your projects on time and within budget Commissioning: Ensures your actual performance versus design, through on site testing & commissioning, tools & procedures Operate How do I operate and maintain? Optimize How do I optimize? Renew How do I renew my solution? Operate Schneider Electric helps you maximize your installation uptime and control your capital expenditures through its service offering. Asset operation solutions: The information you need to increase safety, enhance installation performance, and optimize asset maintenance and investment Advantage service plans: Customized service plans which cover preventive, predictive and corrective maintenance On site maintenance services: Extensive knowledge and experience in electrical distribution maintenance Spare parts management: Ensure spare parts availability and optimized maintenance budget of your spare parts Technical training: To build up necessary skills and competencies. in order to properly operate your installations in safety Optimize Schneider Electric provides recommendations for improved safety, availability, reliability & quality. MP4 electrical assessment: Define improvement & risk management program 126 Premset Catalog schneider-electric.com

127 Connections Schneider Electric Services Peace of mind throughout your installation life cycle When it comes to your electrical distribution installation, we can help you: Increase productivity, reliability, and safety Mitigate risk and limit downtime Keep equipment up to date and extend lifespan Cut cost and increase savings Improve your return on investment Renew Schneider Electric extends the life of your system while providing upgrades. Schneider Electric offers to take full responsibility for the end-of-life processing of old electrical equipments. ECOFIT : Keep up to date & improve performance of your electrical installations (LV, MV, Protection Relays) MV product end of life: Recycle & recover outdated equipment with end of life services CONTACT US! electricaldistributionservices schneider-electric.com Premset Catalog 127

128 Connections Facility Hero Preventive & predictive maintenance using QR codes What is Facility Hero? Facility Hero is a smart maintenance log book that can be accessed from any smartphone, tablet, or computer. This 100% collaborative, connected system keeps maintenance technicians in the field in constant contact with their maintenance community: manager, customer, contractors and peers for fast and effective interventions. Accessible by anyone, anywhere, anytime Facility Hero works on 3G, 4G, and Wi-fi networks and can also be used offline. Simply download the application right to your smartphone or tablet, set up an account, and get started. The right information, fast Overall view of equipment (status, tasks, the week's reminders) Full maintenance logs (breakdowns, maintenance reports) Fast access to history equipment maintenance logs via the QR code on the equipment Rich maintenance reports including voice memos, notes, photos, and measurements The right decision and the right action at the right time Quickly add a new piece of equipment Access periodic reading measurements, recent malfunctions Locate equipment by GPS in real time Monitor equipment remotely and in real time Manage your maintenance teams and interventions effectively Real-time work orders sharing, and reporting with selected users Get inspection reports by mail and share them in just two clicks Monitor all regular operations such as scheduling, and incomplete or upcoming tasks 128 Premset Catalog schneider-electric.com

129 Connections Facility Hero Preventive & predictive maintenance using QR codes Facility Hero New improve the efficiency on maintenance! FACILITY HERO BENEFITS Enhance the efficiency of maintenance operations and insure your uptime: Access automatically to your Premset equipment maintenance planning by flashing the QR code Find the QR codes on your products or on the catalogue product data sheet MV product end of life: Recycle & recover outdated equipment with end of life services > Download the free version of Facility Hero: Access automatically to the maintenance recommendations of your equipments by flashing the QR codes Cloud Logbook to organise and follow your maintenance Remote alarming > Access to the maintenance of your equipement: Circuit breaker function Switch function Metering & other functions schneider-electric.com Premset Catalog 129

130 Technical appendix 130 Premset Catalog schneider-electric.com

131 Technical appendix Dimensions 132 Civil engineering 137 Ground preparation 137 Standard design 138 Arc control design (upwards exhaust) 139 Arc control design (downwards exhaust) 140 Raising plinths 142 VIP tripping curves 143 VIP 40 and VIP 45 tripping curve 143 VIP 400 and VIP 410 tripping curves 144 Order form - Premset (indoor) standard offer 146 schneider-electric.com Premset Catalog 131

132 Technical appendix Dimensions Unit type Height Width Depth (1) Weight (2) (mm) (mm) (mm) (kg) (kg) I06T I06H D01N D02N D06N D06H E-SB G M06S M06A VTM VTP VTM-D VTP-D VTM-C VTM-F VTF I12H D12H M12S M12A G Weight with packing (1) With arc control design, when it is front cable connection, the depth: 1135 mm, when it is rear cable connection, the depth : 1208 mm (2) With arc control design, when it is front cable connection, the weight increases 20 kg, when it is rear cable connection, the weight increases 50 kg Floor preparation Units may be installed on ordinary concrete floors, with or without trenches depending on the type and crosssection of cables. Required civil works are identical for all units. Fixing of units With each other The units are simply bolted together to form the MV switchboard (bolts supplied). To the floor For switchboards comprising up to three units, the four corners of the switchboard must be fixed to the floor using: - bolts (not supplied) screwed into nuts set into the floor using a sealing pistol - threaded rods grouted into the ground For switchboards comprising more than three units, the number and position of fixing points depends on local criteria (earthquake withstand capacities). 132 Premset Catalog schneider-electric.com

133 Technical appendix Dimensions Fixing the Switchboard on the floor Front cable connection Fixing without internal arc exhausting Use spit drills to fix the cubicles on the floor Fix each cubicle using the 2 holes at the rear bottom corners and the 2 ground fixing brackets at the front Nota: the rear brackets are not required except for seismic constraints Fixing with internal arc exhausting DM holes Ø 14 SM holes Ø Front fixations 315 Chimney 375 Front fixations DM holes Ø 14 SM holes Ø Front fixations 315 Chimney 375 Front fixations Front fixations 315 Chimney 375 Front fixations All dimensions in mm. Rear cable connection DM DM Chimney holes Ø Front fixations 7 holes Ø Chimney 375 Front fixations Chimney 375 Front fixations All dimensions in mm. schneider-electric.com Premset Catalog 133

134 Technical appendix Dimensions For non internal arc application Front cable connection 375 mm wide cubicle, 630 A Cable termination height: 500 mm All dimensions in mm. SM C-Max C B D & E A H LV cabinet A 1127 H1 LV cabinet A (when no cable 1350 testing device) H2 LV cabinet D & E 1461 B H5 H3 H4 H2 H1 H H3 LV cabinet B 1573 H4 LV cabinet C H5 LV cabinet C-Max 2045 B1 Non internal arc 1336 D1 Without internal arc exhausting 910 Note: Dimensions are the same for bar-connected cubicles D mm wide cubicle, 630 A Cable termination height: 700 mm (For I12H and D12H: 750 mm wide cubicle) All dimensions in mm. SM C-Max C B D & E A H LV cabinet A 1327 H1 LV cabinet A (when no cable 1550 testing device) H2 LV cabinet D & E 1661 H3 LV cabinet B 1773 B H5 H3 H4 H2 H1 H H4 LV cabinet C 1995 H5 LV cabinet C-Max B1 Non internal arc 1536 D1 Without internal arc exhausting 910 Note: Dimensions are the same for bar-connected cubicles D Premset Catalog schneider-electric.com

135 Technical appendix Dimensions For internal arc application Front cable connection 375 mm wide cubicle, 630 A Cable termination height: 500 mm All dimensions in mm. SM C-Max C B D & E A H LV cabinet A 1127 H1 LV cabinet A (when no cable 1350 testing device) H2 LV cabinet D & E 1461 H3 LV cabinet B 1573 B3 B H3 H4H5 H2 H1 H H4 LV cabinet C 1795 H5 LV cabinet C-Max B2 Internal arc bottom exhaust 1349 B3 Internal arc top exhaust 1664 D2 With internal arc exhausting 1135 Note: Dimensions are the same for bar-connected cubicles D mm wide cubicle, 630 A Cable termination height: 700 mm (For I12H and D12H: 750 mm wide cubicle) All dimensions in mm. SM C-Max C B D & E A 289 H LV cabinet A 1327 H1 LV cabinet A (when no cable 1550 testing device) H2 LV cabinet D & E 1661 B4 B3 B2 79 H5 H3 H4 H2 H1 H H3 LV cabinet B 1773 H4 LV cabinet C H5 LV cabinet C-Max 2245 B2 Internal arc bottom exhaust 1549 B3 Internal arc top exhaust 1864 D2 With internal arc exhausting D2 40 Note: Dimensions are the same for bar-connected cubicles. schneider-electric.com Premset Catalog 135

136 Technical appendix Dimensions For internal arc application Rear cable connection 375 mm wide cubicle, 630 A Cable termination height: 700 mm (For I12H and D12H: 750 mm wide cubicle) SM C-Max C B D & E A All dimensions in mm. H1 LV cabinet A (when no cable 1550 testing device) H2 LV cabinet D & E 1661 H3 LV cabinet B 1773 H4 LV cabinet C 1995 H5 LV cabinet C-Max 2245 B3 B H H1 H5 H4 H3 H2 B1 Door top entry Door bottom entry B1 B2 Internal arc bottom exhaust 1549 B3 Internal arc top exhaust 1864 D2 With internal arc exhausting 1262 Note: Dimensions are the same for bar-connected cubicles D mm Wide Cubicle, 1250 A Cable termination height: 700 mm SM C All dimensions in mm. H LV cabinet A 1327 H1 LV cabinet A (when no cable testing 1550 device) H4 LV cabinet C 1995 B2 Internal arc bottom exhaust 1549 B3 Internal arc top exhaust 1864 D2 With internal arc exhausting 1262 B3 B A 79 H4 H1 Note: Dimensions are the same for bar-connected cubicles. 700 B1 H D Premset Catalog schneider-electric.com

137 OK Technical appendix Civil engineering Ground preparation To ensure the internal arc performance, ground implementation must comply with following requirements: Floor flatness tolerance is within 7mm per 2m Failure to follow these instructions can result in equipment damage, not maintain the internal arc performance. SM OK DM OK OK OK OK I O schneider-electric.com Premset Catalog 137

138 Technical appendix Civil engineering Standard design DM Cable connection and cable trench Cable insulation Cable Cross-section (mm 2 ) Bending radius R (mm) Cable trench depth P (mm) Dry insulation Single-core to Three-core mm P R 50 mm Paper impregnated non-draining type Single-core to Three-core to Note: trench depths can be reduced and sometimes eliminated by adding a plinth. Trench depth P for Premset without plinth. Position of cubicles in a substation Installation of a switchboard with standard design DE58658 (1) 100 mm (2) 910 mm 100 mm (minimum) 500 mm (minimum) (1) 500 mm is recommended for ease of installation and maintenance. (2) 500 mm is requested if there is M06A, M12A, D12H and I12H. 138 Premset Catalog schneider-electric.com

139 Technical appendix Civil engineering Arc control design (upwards exhaust) Front cable connection For cable connection and cable trench request please consult Standard design Installation of a switchboard With arc control design: A-FLR with upwards exhaust left side (ceiling height 2500mm) Evacuation duct conduit DE mm mm 680 mm To enable the evacuation of gases by the top, users must install a conduit fixed to the coupling flange at right or left of the switchboard. For IP3X protection performance, a flap must be installed with this coupling flange on the lateral side of the cubicle duct mm Premset The end of the duct must block water, dust, moisture, animals, from entering and at the same time enable the evacuation of gases into a dedicated area through a device situated at the outer and of the duct (not supplied). Evacuation duct conduit example The evacuation duct must be made of metal sheet of sufficient thickness to withstand pressure and hot gases. Duct (not supplied) The thickness of metal 1.5mm DE58661 Position of cubicle in a substation With arc control design: A-FLR with upwards exhaust (1) (2) 100 mm 1135 mm Coupling flange (supplied) PE mm (minimum) 500 mm (minimum) (1) 500 mm is recommended for ease of installation and maintenance. (2) 500 mm is requested if there is M06A, M12A, D12H and I12H Note: evacuation duct must be manufactured in accordance with the architecture of the building from switchboard to outside schneider-electric.com Premset Catalog 139

Innovation for MV distribution

Innovation for MV distribution Innovation for MV distribution Introducing Premset switchgear, a new way to design, install, and operate MV networks. schneider-electric.us/premset 2 schneider-electric.us/premset schneider-electric.us/premset

More information

VIP 40/45 VIP 400/410

VIP 40/45 VIP 400/410 40/45 400/410 Selection guide 01 PM100573 40/45 PM100576 400/410 self-powered integrated protection relay Optimised performance for transformer, incomer, feeder and bus riser protection Complete engineered

More information

Medium Voltage Air Insulated Switchgear for Secondary Distribution Product overview

Medium Voltage Air Insulated Switchgear for Secondary Distribution Product overview EXTERNAL VERSION PRODUCT PRESENTATION, NOVEMBER 2017 UniSec Medium Voltage Air Insulated Switchgear for Secondary Distribution Product overview Secondary Distribution General product positioning Commercial

More information

GHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits

GHA. Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv. Gas-Insulated Switchgear. Customer Benefits 01 Gas-Insulated Circuit-Breaker Switchgear Unit up to 40.5 kv PM103255 Energy supply security is our permanent challenge. At Schneider Electric, we are constantly developing and improving our products

More information

Air-insulated medium-voltage secondary distribution switchgear

Air-insulated medium-voltage secondary distribution switchgear DISTRIBUTION SOLUTIONS Air-insulated medium-voltage secondary distribution switchgear Compact size Complete solution Factory tested Air-insulated medium-voltage secondary distribution switchgear The ABB

More information

Innovation on Medium Voltage Switchgear

Innovation on Medium Voltage Switchgear Bruno Rivas, Guarulhos - Brazil, April 2015 Jornadas Técnicas de ABB en Chile Innovation on Medium Voltage Switchgear May 13, 2015 Slide 1 Application 13. Mai 2015 Slide 2 PPMV Brazil Factory Unigear Insourcing

More information

power pazifik MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv

power pazifik MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv Manufactured by: MV Switchgear Secondary Distribution Networks Fully Gas-Insulated Modular and Compact (RMU) System Up to 36 kv BO-CGM.3/3 SMART RMU Switchgear in Metro Manila Protection and safety for

More information

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium

Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium Our Power & Control line of Business offers solutions that safely distribute power to your home or business. Our product range includes Low/Medium Voltage Panels and Enclosures designed and built with

More information

Medium Voltage Distribution Catalogue GenieEvo range. Air Insulated MV Switchgear kv

Medium Voltage Distribution Catalogue GenieEvo range. Air Insulated MV Switchgear kv Medium Voltage Distribution Catalogue 2015 GenieEvo range Air Insulated MV Switchgear 3.3-13.8 kv Medium Voltage Distribution GenieEvo Your requirements Peace of mind Energy availability Safety GenieEvo

More information

Benefits, offering and references

Benefits, offering and references DOC ID: 9AKK107045A9180 DISTRIBUTION SOLUTIONS Digital medium-voltage switchgear Benefits, offering and references Contents Digital switchgear for medium-voltage applications Digital switchgear definition

More information

MV Network Switchgear, Protection and Control

MV Network Switchgear, Protection and Control MV Network Switchgear, Protection and Control Ravinder Negi Manager, Services Execution INDIA Schneider Electric, New Delhi. Agenda An Overview MV Network Basic Definitions Circuit breaker Switchgear Control

More information

Products Portfolio. Pole mounted Vacuum Recloser

Products Portfolio. Pole mounted Vacuum Recloser Products Portfolio Pole mounted Vacuum Recloser Efacec Switchgear Efacec Switchgear is a leading company in Portugal and a worldwide reference in the development of solutions for power generation, transmission,

More information

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety

MEDIUM VOLTAGE PRODUCTS. UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety MEDIUM VOLTAGE PRODUCTS UniSec Air-insulated medium voltage secondary distribution switchgear Informed choice for safety 2 UNISEC AIR-INSULATED MEDIUM VOLTAGE SECONDARY DISTRIBUTION SWITCHGEAR Operator

More information

11 kv Indoor Switchgear - SCADA Controlled

11 kv Indoor Switchgear - SCADA Controlled Specification 11 kv Indoor Switchgear - SCADA Controlled Important Warning This document is one of a set of standards developed solely and specifically for use on the rail network owned or managed by the

More information

Package Substation. The efficient solution for your electrical distribution network

Package Substation. The efficient solution for your electrical distribution network Package Substation The efficient solution for your electrical distribution network Why Prefabricated Substations? Biosco, safe and effective substations Safety: A fully tested electrical equipment > Much

More information

KMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available

KMP A3. Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available KMP A3 Air Insulated Medium Voltage Switchgear Powerful. Safe. Highly Available High power switchgear systems For primary applications The name MediPower represents powerful medium voltage energy distribution

More information

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers

Symmetra PX 48kW. Scalable from 16 to 48kW. Make the most of your energy TM. Modular, Scalable, High-Efficiency Power Protection for Data Centers Symmetra PX 48kW Scalable from 16 to 48kW Modular, Scalable, High-Efficiency Power Protection for Data Centers High performance, right-sized, modular, scalable, 3-phase power protection with high efficiency

More information

Premset. 15 kv Compact modular vacuum switchgear. Make the most of your energy. Medium Voltage Distribution Catalogue 2013

Premset. 15 kv Compact modular vacuum switchgear. Make the most of your energy. Medium Voltage Distribution Catalogue 2013 Medium Voltage Distribution Catalogue 2013 Premset 15 kv Compact modular vacuum switchgear With Shielded Solid Insulation System Make the most of your energy 2 AMTED399053EN Premset General contents Overview

More information

Grid Automation packaged solutions Optimal automation of medium voltage grids

Grid Automation packaged solutions Optimal automation of medium voltage grids Grid Automation packaged solutions Optimal automation of medium voltage grids Application principles of the Zone concept Grid Automation (GA) packaged solutions The zone concept offers a method to analyze

More information

MEDIUM VOLTAGE RING MAIN UNIT

MEDIUM VOLTAGE RING MAIN UNIT MEDIUM VOLTAGE RING MAIN UNIT SFA-RM up to www.alfanar.com Contents 1 - Introduction 4 Introduction to SFA-RM 4 a - SFA - RM Solution 4 b - Quality Management 4 c - Quality Checks and Tests 4 d - Environmental

More information

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD

24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD United States 24973 Circuit Breaker MINIATURE CIRCUIT BREAKER, 440VAC, 10A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Approvals: IEC 60947-2 Rated

More information

Power Transmission Division Link between power generation and distribution

Power Transmission Division Link between power generation and distribution Power Transmission Division Link between power generation and distribution Seite 4 High Voltage Substations Schemes, Devices and Types of AIS Installation Content Link between power generation and distribution

More information

UniSec, MV AIS for Secondary Distribution Smart Grid applications

UniSec, MV AIS for Secondary Distribution Smart Grid applications Ing. Natalia Moizzes- Switchgear Product Specialist Chile Abril 14 th 2015 UniSec, MV AIS for Secondary Distribution Smart Grid applications Slide 1 Concept - Needs and Solutions Requests are: Manage faults

More information

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards)

////// SUBSTATIONS. DC Switchgear Range. Type MBS (IEEE/ANSI standards) ////// SUBSTATIONS DC Switchgear Range Type MBS (IEEE/ANSI standards) GENERAL INFORMATION With a complete range of equipment and a leading expertise in DC traction power substations, Sécheron SA is a world

More information

Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS

Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS Rapier GX Gas Enclosed Load Break Switch and Sectionaliser up to 38kV with automation or remote control options ENGINEERING BRILLIANT SOLUTIONS RAPIER GX Gas Enclosed Switch Our new RAPIER GX, pole-mounted

More information

PROTECTION RELAYS: INNOVATIONS FOR THE BENEFIT OF THE USER

PROTECTION RELAYS: INNOVATIONS FOR THE BENEFIT OF THE USER PROTECTION RELAYS: INNOVATIONS FOR THE BENEFIT OF THE USER C. Petit Schneider Electric, France Innovation in the field of medium voltage protection devices is accelerating to meet the ever growing demands

More information

ABB Digital medium-voltage switchgear

ABB Digital medium-voltage switchgear NAMIBIA AMEU/AEDU MARCH 2018 ABB Digital medium-voltage switchgear Barry Addinall UniGear Digital Contents 1. Digital switchgear 2. Complexity of Distribution networks 3. New technologies using digital

More information

Protection relays.

Protection relays. Protection relays www.vamp.fi Vamp Ltd Vamp Ltd, with a strong experience of designing devices, is an independent supplier of relays and monitoring equipment. The company has an established reputation

More information

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution

Sentron 3VT circuit breakers Simply Smart: First choice for power distribution s Sentron 3VT circuit breakers Simply Smart: First choice for power distribution www.siemens.com/industry Sentron 3VT Molded Case Circuit-Breakers - 10-1600Amperes With the standard line of 3VT molded-case

More information

SIEMENS 8DJH 11/22 kv Ring Main Units

SIEMENS 8DJH 11/22 kv Ring Main Units POWER AUTOMATION TECHNOLOGIES SIEMENS 8DJH 11/22 kv Ring Main Units Overview of Outdoor and Indoor solutions 01 02 Transformer Kiosk Indoor on Base Absorber Class A 03 07 Outdoor Class A Outdoor Class

More information

ABB AG - EPDS. Gas-insulated switchgear Type ZX2

ABB AG - EPDS. Gas-insulated switchgear Type ZX2 ABB AG - EPDS Gas-insulated switchgear Medium voltage switchgear Single or double busbar systems 12 kv, 2500 A, 40 ka 24 kv, 2500 A, 40 ka 36 kv, 2500 A, 40 ka Slide 2 Medium voltage switchgear With IAC

More information

POWER GRID AUTOMATION. Pág.. n. RMU Automation

POWER GRID AUTOMATION. Pág.. n. RMU Automation POWER GRID AUTOMATION RMU Automation Distribution Network Non-Controlled Secondary Distribution Systems Distribution Network RMU Automation - Levels RMU Automation - RTU / FRTU SMART CONTROLLER Monitoring

More information

ABB AG Calor Emag Medium Voltage Products Gas-insulated switchgear Type ZX2. ABB Gas-insulated switchgear type ZX2 1

ABB AG Calor Emag Medium Voltage Products Gas-insulated switchgear Type ZX2. ABB Gas-insulated switchgear type ZX2 1 ABB AG Calor Emag Medium Voltage Products Gas-insulated switchgear 17.02.2015 Gas-insulated switchgear type ZX2 1 Medium voltage switchgear type ZX2 Single or double busbar systems 12 kv, 2500 A, 40 ka

More information

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip

Sivacon S4. Low-Voltage Switchboards. siemens.co.uk/tip Product Managers and dedicated Business Development Managers are available to assist with all your enquiries. Technical presentations (Forms of Separation, Discrimination etc) available Site response capability

More information

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection

1S20. Arc Fault Monitor Relay. Features. Introduction. ARC Fault Protection Technical Bulletin Arc Fault Monitor Relay Features Compact, economic design Simple panel mounting for retrofit applications Two or three arc sensor inputs Two high speed tripping duty arc sense output

More information

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager

MNS Platform, low voltage systems Rear Access Power Motor Control Center. Alberto Carini, Global Product Manager MNS Platform, low voltage systems Rear Access Power Motor Control Center Alberto Carini, Global Product Manager MNS Platform, low voltage systems Add Value to our customers Sales After sales Maximum safety;

More information

Performance. Simplicity. Sepam, over 20 years of experience of the world leader. Sepam protection relays. For your peace of mind

Performance. Simplicity. Sepam, over 20 years of experience of the world leader. Sepam protection relays. For your peace of mind Performance to serve your installation better Effective b Thermal based on temperature rise calculation with predictive data to optimize process control. b Directional phase overcurrent for ring networks.

More information

Catalog. Arc Guard System TM TVOC-2

Catalog. Arc Guard System TM TVOC-2 Catalog Arc Guard System TM TVOC-2 Introduction An even better Arc Guard System TVOC-2, ABB s latest Arc Monitor, builds on the well known TVOC design. Its new functions and features improve an already

More information

DESCRIPTIVE BULLETIN. SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear

DESCRIPTIVE BULLETIN. SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear DESCRIPTIVE BULLETIN SafeGear 5/15 kv, up to 50 ka arc-resistant switchgear 2 S A F E G E A R 5/ 1 5 K V, U P TO 5 0 K A A R C - R E S I S TA N T S W I TC H G E A R SafeGear meets today s challenge for

More information

MESP TECHNICAL SPECIFICATION FOR 22 kv METAL ENCLOSED SWITCHGEAR

MESP TECHNICAL SPECIFICATION FOR 22 kv METAL ENCLOSED SWITCHGEAR Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR 22 kv Version: 2 Issued: 19 th December 2016 Owner: Chief Engineer Approved By: Andrew Russack Head of Engineering - Electrical

More information

Modular, scalable, high-efficiency power protection for data centers

Modular, scalable, high-efficiency power protection for data centers Scalable from 16 kw to 160 kw Modular, scalable, high-efficiency power protection for data centers The right-sized UPS for demanding business-critical applications The Schneider Electric Symmetra PX 96/160

More information

60103 Circuit Breaker

60103 Circuit Breaker 6003 Circuit Breaker United States MINIATURE CIRCUIT BREAKER, 20/240VAC, 2A, CIRCUIT BREAKER TYPE: STANDARD Image not available Product Information Features and Specifications Circuit Breaker Type: Standard

More information

Ground Breaking MV Switchgear

Ground Breaking MV Switchgear ISO 9001:2008 and ISO 14001:2004 certification ETALON Ground Breaking MV Switchgear Etalon is vacuum switchgear that fits most of the switchgear applications available and meets the most strict safety

More information

SACE Emax 2 Specification guide

SACE Emax 2 Specification guide SACE Emax 2 Specification guide Specification Number: 26 01 20.17 Product Name: LOW VOLTAGE POWER CIRCUIT BREAKERS PART 1 GENERAL NOTE: ( ) Indicates option or a selection is to be made for quantity or

More information

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD

MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD United States MG24434 Supplementary Protector SUPPLEMENTARY PROTECTOR, 240VAC, 16A, CIRCUIT BREAKER TYPE: STANDARD Product Information Features and Specifications For Use With: OEM Panels Approvals: UL

More information

CENTERLINE 2500 Motor Control Centers

CENTERLINE 2500 Motor Control Centers CENTERLINE 2500 Motor Control Centers High Performance Motor Control Centers and Switch Gear Meeting IEC 61439-2 Product Description Allen-Bradley CENTERLINE 2500 motor control centers (MCCs) are designed

More information

IEC & 2 standard. The reference for safe and reliable LV switchboards

IEC & 2 standard. The reference for safe and reliable LV switchboards IEC 61439-1 & 2 standard The reference for safe and reliable LV switchboards IEC61439-1 & 2 The power of a standard adapted to your needs IEC standards are today legal or market references. The new IEC

More information

Prisma Plus System P Cubicles up to 4000 A

Prisma Plus System P Cubicles up to 4000 A Low Voltage electric distribution Prisma Plus System P Cubicles up to 4000 A Catalogue 2012 Presentation PD390180_SE.eps IP30/31/55 cubicles b Applications: v indoor cubicles for main or subdistribution

More information

MGE Galaxy /900 kva

MGE Galaxy /900 kva MGE Galaxy 9000 800/900 kva Data centers are becoming increasingly large, Blade Servers are demanding more power, and there is increasing demand from semi conductors for the digital economy. The MGE Galaxy

More information

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical

.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of

More information

BCM2 Series Branch Circuit Monitors Quick Setup Guide

BCM2 Series Branch Circuit Monitors Quick Setup Guide BCM2 Series Branch Circuit Monitors Quick Setup Guide Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw Unique, fully modular and redundant solution The solution for > Computer rooms > Data centres > Banks > Healthcare facilities > Insurance > Telecom Advantages > Ensures absolute business continuity > Aligns

More information

Merlin Gerin GenieEvo metalclad MV switchgear kV Selection guide

Merlin Gerin GenieEvo metalclad MV switchgear kV Selection guide Merlin Gerin GenieEvo metalclad MV switchgear 3.3-13.8kV Selection guide GenieEvo selection guide Contents Section one Product overview 5 Section two Introduction 15 Section three Network functions Summary

More information

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21

ATV930U30M3 variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Characteristics variable speed drive - ATV930-3kW - 200/240Vwith braking unit - IP21 Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

ENhanced TEChnology. Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver.

ENhanced TEChnology.  Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV. Ver. ENhanced TEChnology www.entecene.co.kr Solid insulated vacuum recloser for power distribution system thru 15kV, 27kV, 38kV Ver. 081226 General features We, ENTEC introduce a Solid Insulated Vacuum Recloser

More information

Type 8DA and 8DB up to 40.5 kv, Gas-Insulated

Type 8DA and 8DB up to 40.5 kv, Gas-Insulated Catalog H 35.11 Edition September 2017 Fixed-Mounted d Circuit-Breaker it Switchgear Type 8D and 8DB up to 40.5 kv, Gas-Insulated Medium-Voltage Switchgear siemens.com/medium-voltage-switchgear pplication

More information

Section 4 Ground-Fault Protection Devices

Section 4 Ground-Fault Protection Devices Multi 9 System Catalog Section 4Ground-Fault Protection Devices Section 4Ground-Fault Protection Devices Selection Table The Multi 9 System includes one UL Listed and three IEC rated product families that

More information

Flair 21D - 22D - 23D - 23DM Self-powered, adjustment-free fault passage indicators

Flair 21D - 22D - 23D - 23DM Self-powered, adjustment-free fault passage indicators Technical leaflet - MV network management 01 Self-powered, adjustment-free fault passage indicators EMS58355 1 Customer benefits At the cutting edge of technology, they are used on underground MV networks

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM

MESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V Version: 1 Issued: March 2014 Owner: Electrical Networks Asset

More information

Medium voltage switchgear With fixed pattern circuit breaker GenieEvo

Medium voltage switchgear With fixed pattern circuit breaker GenieEvo Medium voltage switchgear With fixed pattern circuit breaker GenieEvo Simple and highly reliable switchgear for primary and secondary distribution GenieEvo is an indoor switchgear assembly circuit breaker

More information

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet

ATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet Characteristics variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups

Galaxy VX. From 500 to 1500 kw N+1 Parallel solutions up to 4000 kw 380V / 400V / 415V / 440V. schneider-electric.com/ups Galaxy VX Highly efficient, scalable, three-phase power protection with flexible operating modes and ECOnversion for large facilities, data centers, and business-critical applications. From 500 to 1500

More information

Build electrical installations more efficiently. Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A

Build electrical installations more efficiently. Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A Build electrical installations more efficiently Prisma Plus P Simple, functional systems for safe, upgradeable LV switchboards up to 3200 A Develop your business efficiency w Switchboards that are safe

More information

Grid Automation Controller COM600 How it fits into the Smart Grid?

Grid Automation Controller COM600 How it fits into the Smart Grid? ABB Oy Distribution Automation Grid Automation Controller How it fits into the Smart Grid? May 27, 2014 Slide 1 1MRS756763 E Content Technical Presentation May 27, 2014 Slide 2 Description Grid Automation

More information

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw

MODULYS GP Unique, fully modular and redundant solution Green Power 2.0 range from 25 to 600 kva/kw Unique, fully modular and redundant solution The solution for > Computer rooms > Data centres > Banks > Healthcare facilities > Insurance > Telecom Advantages > Ensures absolute business continuity > Aligns

More information

TRENDS IN SWITCHGEAR SPECIFICATIONS

TRENDS IN SWITCHGEAR SPECIFICATIONS TRENDS IN SWITCHGEAR SPECIFICATIONS What changes are we seeing in equipment specifications? What s being discussed in client meetings? What s happening in the market to support these requests? EQUIPMENT

More information

COMPACT SUBSTATION WITH 34.5kV GIS (GAS-INSULATED SWITCHGEAR. Cleverson Shindi Takiguchi S&C Electric Europe LTd. Cape Town/WC South Africa

COMPACT SUBSTATION WITH 34.5kV GIS (GAS-INSULATED SWITCHGEAR. Cleverson Shindi Takiguchi S&C Electric Europe LTd. Cape Town/WC South Africa COMPACT SUBSTATION WITH 34.5kV GIS (GAS-INSULATED SWITCHGEAR Cleverson Shindi Takiguchi S&C Electric Europe LTd. Cape Town/WC South Africa Alexandre Taijun Ohara S&C Electric Company Curitiba/PR Brazil

More information

ELG4125: System Protection

ELG4125: System Protection ELG4125: System Protection System Protection Any power system is prone to 'faults', (also called short-circuits), which occur mostly as a result of insulation failure and sometimes due to external causes.

More information

Modular, scalable, high-efficiency power protection for data centers

Modular, scalable, high-efficiency power protection for data centers Scalable to 20 kw Modular, scalable, high-efficiency power protection for data centers The Symmetra TM PX 20 kw is a world-class, high-efficiency, ENERGY STAR qualified power protection system designed

More information

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1

ATV630U15N4 variable speed drive ATV kW/2HP V - IP21/UL type 1 Product datasheet Characteristics ATV630U15N4 variable speed drive ATV630-1.5kW/2HP - 380...480V - IP21/UL type 1 Main Range of product Product or component type Product specific application Device short

More information

SECTION SWITCHBOARDS

SECTION SWITCHBOARDS SECTION 26 24 13 PART 1 - GENERAL 1.1 SUMMARY A. Work Included: 1. Switchboards 2. Commercial Metering Switchboards 3. Non-Utility Power Meters (Microprocessor-Based Metering Equipment) PART 2 - PRODUCTS

More information

Switching gears. Moving to smart switchgear for primary and secondary substations

Switching gears. Moving to smart switchgear for primary and secondary substations Moving to smart switchgear for primary and secondary substations VINCENZO BALZANO, MARTIN CELKO Medium-voltage (MV) distribution systems are undergoing a revolution: Gone are the days when they merely

More information

Netcon 100. Smart Platform for Distribution Automation. Control and monitoring solution for intelligent electricity distribution networks

Netcon 100. Smart Platform for Distribution Automation. Control and monitoring solution for intelligent electricity distribution networks Netcon 100 Smart Platform for Distribution Automation Control and monitoring solution for intelligent electricity distribution networks Remote and local control of switching devices Overcurrent and earth

More information

SWITCHGEAR MODELS CEP 14 / 15

SWITCHGEAR MODELS CEP 14 / 15 PRODUCT LEAFLET SWITCHGEAR MODELS CEP 14 / 15 For network 950 V - 3,200 V - 5,500 V - 6,600 V Switchgear with three compartments Outgoing feeder contactor Switchgear with two compartments Outgoing feeder

More information

Business continuity made easy

Business continuity made easy Business continuity made easy Schneider Electric Easy UPS 3 Series Easy UPS 3S: 220/230/240/380/400/415V Easy UPS 3M: 380/400/415V schneider-electric.com/ups Business continuity made easy The Schneider

More information

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch

ATV650U30N4E variable speed drive ATV650-3kW V - IP55 - disconnect switch Characteristics variable speed drive ATV650-3kW - 380...480V - IP55 - disconnect switch Main Range of product Product or component type Product specific application Device short name Variant Product destination

More information

ATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet

ATV340D18N4E variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet Characteristics variable speed drive - 18kW- 400V - 3 phases - ATV340 Ethernet Main Range of product Product or component type Device application Device short name Variant Product destination Mounting

More information

EMS CX 3 - State and control module for Latching relays and Contactors

EMS CX 3 - State and control module for Latching relays and Contactors LEGRAND - BP30076 87045 LIMOGES CEDEX FRANCE Telephone: 05 55 06 87 87 Fax: 05 55 06 88 88 Contents Pages 1. Description - Use... 1 2. Range... 1 3. Overall dimensions... 1 4. Preparation - Connection...

More information

Overvoltage Protection Devices

Overvoltage Protection Devices Siemens AG 2010 Overvoltage Protection Devices /2 Introduction /3 Lightning Arresters, Type 1 /5 Combination Surge Arresters, Type 1 and Type 2 /7 Surge Arresters, Type 2 /11 Surge Arresters, Type 3 /12

More information

Compact NSX communication

Compact NSX communication Functions and characteristics Compact NSX communication Communications modules All Compact NSX devices can be equipped with the communication function via a prewired connection system and a Modbus network

More information

Quasar Series Technical Features

Quasar Series Technical Features Product Description The Quasar Series is a modern imcc (Intelligent Motor Control Center) switchboard line for low voltage and currents up to 3150 A, and in compliance with IEC 60439-1 - TTA compliant

More information

VisoVac padmount fault interrupter

VisoVac padmount fault interrupter Network Protector Catalog Data CA024003EN New Issue VisoVac padmount fault interrupter General The medium voltage padmount vacuum fault interrupter from Eaton delivers economical, reliable and flexible

More information

Bus Bar Protection Relay B-PRO 4000

Bus Bar Protection Relay B-PRO 4000 Bus Bar Protection Relay B-PRO 4000 Product Overview The IEC 61850 station bus embedded B-PRO 4000 relay provides complete bus and substation differential protection (low impedance) with CT saturation

More information

Lowering Lifecycle Costs

Lowering Lifecycle Costs Lowering Lifecycle Costs with Intelligent Motor Control Centers Standards Certification Education & Training Publishing Conferences & Exhibits Speakers: Presented and Authored by Jeff M. Miller, PE, ENV

More information

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services.

Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much to maintain aging switchgear? Circuit breaker solutions from Square D Services. Spending too much time and money on equipment maintenance? Square D Services: Your source for circuit breaker

More information

Circuit Breakers,Reclosers, Switches, and Fuses

Circuit Breakers,Reclosers, Switches, and Fuses Section 17 Circuit Breakers,Reclosers, Switches, and Fuses 170. ARRANGEMENT This rule requires circuit breakers, reclosers, switches, and fuses be accessible only to qualified persons. Section 17 is part

More information

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER!

QUICK SETUP GUIDE. BCM2 Series Branch Circuit Monitors. Safety Information. Equipment Maintenance and Service. Product Overview. Raritan DANGER! QUICK SETUP GUIDE BCM2 Series Branch Circuit Monitors Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA 70E in the USA, or applicable

More information

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field

DTRV-EP. COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS. Application field DTRV-EP COMPLEX DIGITAL PROTECTION FOR 120 kv / MEDIUM VOLTAGE TRANSFORMERS Application field The DTRV type of complex transformer protection is designed to protect 120 kv / medium voltage transformers,

More information

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers

Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power Transformers Session Five: IEC61850 Based Process Bus Protection Solution for Remote Located Power 1. Abstract Dinesh Mithanthaya Design Manager, Horizon Power Higher capacity substation power transformers ( 5MVA),are

More information

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin

Overcurrent and Arc Protection by Reyrolle Alexander Erokhin. 21, 2017 I Berlin Overcurrent and Arc Protection by Reyrolle Alexander Erokhin VAR Partner Day September 20-21, 21, 2017 I Berlin Reyrolle Product Range by SIEMENS Challenges We Meet for our Customers Easy-to-use protection

More information

InHand Wireless. As an important sector of smart grid building, smart distribution network faces the

InHand Wireless. As an important sector of smart grid building, smart distribution network faces the InHand Wireless Overhead Line System Overhead Line Sensor Key Features: Innovative low current (10A) auto power-harvesting technology, maintains network connection and reliable operation Advanced electronic

More information

MiCOM P122C Time-Overcurrent Protection

MiCOM P122C Time-Overcurrent Protection Protection Relays 01 MiCOM P122C Time-Overcurrent Protection Customer Benefits 1A/5A software setting 4 function keys Compact unit for flush and wall-surface mounting Comprehensive measurements Disturbance

More information

EFASOLAR PVStation Solutions

EFASOLAR PVStation Solutions www.efacec.com EFASOLAR PVStation Solutions EFASOLAR PVStation EFASOLAR PVStation Solutions 0,5 MW 1 x EFASOLAR 50 0,50 MW 1 x EFASOLAR 500M 1 MW 1,46 MW Efacec is a century-long experienced company in

More information

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity

Galaxy VM. 160/200 kva Parallel capable up to 800 kva. Three-phase power protection. Galaxy VM trusted partner for your business continuity Galaxy VM 160/200 kva Parallel capable up to 800 kva Three-phase power protection Galaxy VM trusted partner for your business continuity Highly efficient, easy-to-deploy, three-phase power protection that

More information

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1

Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC. ABB Group June 21, 2013 Slide 1 Alberto Carini, LPLS Italy, June 2013 MNS is The Intelligent MCC June 21, 2013 Slide 1 The MCC evolution Traditional MCC Intelligent relays MCC with integrated intelligence June 21, 2013 Slide 2 The intelligent

More information

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus

Non-conventional instrument transformers Advanced GIS substations with IEC LE process bus Non-conventional instrument transformers Advanced GIS substations with IEC 61850-9-2LE process bus Content Towards the digital GIS substations Optimized substation design NCIT for gas-insulated switchgears

More information

Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches

Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches Medium-Voltage Circuit Breaker-Type Automatic Transfer Switches and Bypass/Isolation Switches RTS SERIES RTS Series Medium-Voltage Circuit Breaker-Type Automatic Transfer Circuit breaker medium-voltage

More information

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid

FFI. Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars. Presented By: Greg Pelster & Robert Schmid Advances in Medium and Low Voltage Power Distribution ESS Metron Expo and Technical Seminars Presented By: Greg Pelster & Robert Schmid FFI Ferrie, Franzmann Industries LOW VOLTAGE SWITCHGEAR & LOW VOLTAGE

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA