MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.
|
|
- Gabriella Lindsey
- 5 years ago
- Views:
Transcription
1 MODEL: R-NL Remote I/O R Series LonWorks INTERFACE MODULE (I/O points) 7. (.08) 0 (.) 09 (.9) mm (inch) MODEL: R NL [][] ORDERING INFORMATION Code number: R-NL-[][] Specify a code from below for each [] and []. (e.g. R-NL-R/Q) Specify the specification for option code /Q (e.g. /C0) [] POWER INPUT N: No power supply AC Power K: 00 0 V AC (Operational voltage range 8 - V, 7 - Hz) * L: 00 0 V AC (Operational voltage range 70 - V, 7 - Hz) * DC Power R: V DC (Operational voltage V ±0 %, ripple 0 %p-p max.) * * Not selectable for use with independent power modules. [] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C0: Silicone coating /C0: Polyurethane coating /C0: Rubber coating RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker. GENERAL SPECIFICATIONS Connection Network: Euro type connector terminal (applicable wire size 0. to. mm, stripped length 7 mm) Internal bus: Via the Installation Base (model: R-BSx) Internal power: Via the Installation Base (model: R-BSx) Power input, RUN contact output: M separable screw terminal (torque 0. N m) Screw terminal: Nickel-plated steel Isolation: LonWorks to internal bus or internal power to power input to RUN contact output to FG Input error data: Input value setting at input module error with side DIP SW Slot assignment: Set with the side DIP switch RUN indicator: Bi-color (green/red) LED; Green ON in communications with another device on-line or changing the output data (turns off after seconds of no communication) ERR indicator: Bi-color (green/red) LED; Green ON in normal status; Green blinks when the APB file is not adequately imported; Green/Orange turn ON in turn in an abnormality. RUN CONTACT OUTPUT RUN contact: Turns on while the green RUN LED is ON (LonWorks in normal communication) Rated load: 0 V 0. A (cos ø = ) 0 V 0. A (resistive load) Maximum switching voltage: 0 V AC or 0 V DC Maximum switching power: 0 VA or 0 W Minimum load: V ma Mechanical life: 0 7 cycles (rate 00 cycles/min.) When driving an inductive load, external contact protection and noise quenching recommended. LonWorks COMMUNICATION Neuron Chip: FT0 (NeuronID printed in numbers and bar code [peel-off code 9 format]) Transceiver: FT-X (equivalent to FTT0A) Transmission speed: 78 kbps Twisted-pair cable Distance, free topology: 00 meters Max. nodes/channel LNS: Ver..0 Service Pack 8 or higher ONLINE indicator: Red LED ON: Off-line or no network information (decommissioned) R-NL SPECIFICATIONS ES-88 Rev.9 Page /
2 MODEL: R-NL Blinking in approx. 0. Hz: On-line (ready to communicate network variables) Blinking in approx. Hz for sec: Wink message received SERVICE indicator: Green LED OFF: Normal operations Blinking in approx. 0. Hz: No network information ON: Internal program error SERVICE switch: Used to identify the node in LonWorks network configuration RESET switch: Resetting the Neuron Chip Possible I/O combinations Analog I/O 0 SNVT_lev_percent 0 SNVT_lev_percent SNVT_lev_percent (factory default) PERFORMANCE Insulation resistance: 00 MΩ with 00 V DC Dielectric strength: 00 V minute (LonWorks or internal bus or internal power to power input to RUN contact output to FG) Temperature Input ( C input module use) 0 SNVT_temp 0 SNVT_temp_p Discrete I/O (Usable with the R-DAx and the R-DCx) 0 SNVT_switch 0 SNVT_switch SNVT_switch Totalized Pulse I/O (Usable as analog I/O) 0 SNVT_count 0 SNVT_count SNVT_count Totalized Pulse Input, Discrete I/O (Totalized pulse usable as analog input) (Usable with the R-DAx and the R-DCx) Totalized Pulse Input Discrete Input Output Network Variable Type SNVT_count SNVT_switch INSTALLATION Power consumption AC: Approx. 0 VA DC: Approx. W Current consumption (no power supply): 00 ma Output current (power supply): 0 ma continuous at 0 V DC; 00 ma for 0 minutes Operating temperature: -0 to + C ( to F) Operating humidity: 0 to 90 %RH (non-condensing) Atmosphere: No corrosive gas or heavy dust Mounting: Installation Base (model: R-BSx) Weight: 00 g (0. lb) R-NL SPECIFICATIONS ES-88 Rev.9 Page /
3 MODEL: R-NL EXTERNAL VIEW FRONT VIEW SIDE VIEW ONLINE LED RUN LED SERVICE LED ERR LED Configuration Jack Euro Type Connector Terminal SERVICE SW RESET SW SW ON 8 7 DIP SW SW ON 8 7 SW ON COMMUNICATION CABLE CONNECTIONS HOST PC R-NLx R-NLx Terminator TRANSMISSION DATA DESCRIPTIONS ANALOG INPUT / OUTPUT The DIP SW located at the side of the module specifies each I/O module's data allocation (occupied data area). [Example ] Seven (7) of 8-point analog input module: Module R-SV8S 8 nvolv0 through nvolv08 Module R-SV8S 8 nvolv09 through nvolv Module R-SV8S 8 nvolv7 through nvolv Module R-SV8S 8 nvolv through nvolv Module R-SV8S 8 nvolv through nvolv0 Module R-SV8S 8 nvolv through nvolv8 Module 7 R-SV8S 8 nvolv9 through nvolv Module 8 R-NL-N Module 9 R-PS-R The same principle is applied to Analog Output (RNL-LVO) or Temperature Input (RNL_T, RNL_TP). R-NL SPECIFICATIONS ES-88 Rev.9 Page /
4 MODEL: R-NL DISCRETE INPUT / OUTPUT One () data area can handle points of discrete signals. [Example ] Four () of -point discrete input module: Module R-DAS nvosw0 through nvosw Module R-DAS nvosw7 through nvosw Module R-DAS nvosw through nvosw8 Module R-DAS nvosw9 through nvosw Module R-NL-N Module R-PS-R Channels 9 through of the Module are not transmitted. MIXED I/O Network Variables for the input channels are assigned first, and then those for the output channels are assigned to the next module position. [Example ] Four () of 8-point analog input module and three () of 8-point analog output: Module R-SV8S 8 nvolv0 through nvolv08 Module R-SV8S 8 nvolv09 through nvolv Module R-SV8S 8 nvolv7 through nvolv Module R-SV8S 8 nvolv through nvolv Module R-YV8S 8 nvilv0 through nvilv08 Module R-YV8S 8 nvilv09 through nvilv Module 7 R-YV8S 8 nvilv7 through nvilv Module 8 R-NL-N Module 9 R-PS-R TOTALIZED PULSE INPUT / DISCRETE I/O Network Variables for the discrete input channels are assigned first, and then those for the totalized pulse input channels are assigned to the next module position. Finally those for the discrete output channels are assigned to the following module position. The I/O modules must be assigned as in the fllowing example. Adequate operation is not guaranteed in any other configuration. [Example ] One () of -point totalized pulse input module, one () of -point discrete input module, and one () of -point discrete output: Module R-DAS nvosw0 through nvosw Module R-PAS nvoc0 through nvoc Module R-DCS nvisw0 through nvisw Module R-NL-N Module R-PS-R R-NL SPECIFICATIONS ES-88 Rev.9 Page /
5 MODEL: R-NL I/O COMBINATIONS A dedicated Device File for each I/O device depending upon I/O combinations is required for the setting up using an integration tool such as Lon Maker. On-line download is available for Device Image files at M-System's homepage. Functional Blocks usable for respective files are not identical to all. Refer to the table below. ANALOG INPUT / OUTPUT 0 SNVT_lev_percent RNL_LVI_0.XIF NodeObject RNL_LVI_0.APB NLLVIn 0 SNVT_lev_percent RNL_LVO_0.XIF NodeObject RNL_LVO_0.APB NLLVOut SNVT_lev_percent RNL_LVIO_0.XIF NodeObject RNL_LVIO_0.APB NLLVIO TEMPERATURE INPUT ( C) 0 SNVT_temp RNL_TI_0.XIF NodeObject RNL_TI_0.APB NLTIn 0 SNVT_temp_p RNL_TPI_0.XIF NodeObject RNL_TPI_0.APB NLTPIn DISCRETE INPUT / OUTPUT 0 SNVT_switch RNL_SWI_0.XIF NodeObject RNL_SWI_0.APB NLSWIn 0 SNVT_switch RNL_SWO_0.XIF NodeObject RNL_SWO_0.APB NLSWOut SNVT_switch RNL_SWIO_0.XIF NodeObject RNL_SWIO_0.APB NLSWIO TOTALIZED PULSE INPUT / OUTPUT 0 SNVT_count RNL_CI_0.XIF NodeObject RNL_CI_0.APB NLCIn 0 SNVT_count RNL_CO_0.XIF NodeObject RNL_CO_0.APB NLCOut SNVT_count RNL_CICO_0.XIF NodeObject RNL_CICO_0.APB NLCInOut TOTALIZED PULSE INPUT / DISCRETE INPUT / DISCRETE OUTPUT NO. of DATA USABLE TOTAL. PULSE DISCRETE NETWORK VARIABLE DEVICE IMAGE FUNCTIONAL INPUT BLOCKS SNVT_count RNL_CISWISWO_0.XIF NodeObject SNVT_switch RNL_CISWISWO_0.APB NLCISWIO XIF File: Device Interface File (external interface) APB File: Downloadable Application Image File (program for NeuronChip) R-NL SPECIFICATIONS ES-88 Rev.9 Page /
6 EXTERNAL DIMENSIONS & TERMINAL ASSIGNMENTS unit: mm (inch) MODEL: R-NL 7. (.08) 09 (.9) POSITIONING GUIDE 0 (.) M SCREW. (.) TERMINAL COVER SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Caution: FG terminal is NOT a protective conductor terminal. ONLINE/SERVICE LED RUN/ERR LED RUN + RUN CONTACT OUTPUT RUN Transceiver FT-X SERVICE SW RESET SW Neuron Chip FT0 Control Circuit DIP SW Communication Circuit BUS CONNECTOR INTERNAL BUS INTERNAL POWER U (+) * POWER INPUT V ( ) * * FG CONFIGURATION JACK JACK *Not provided with No Power Supply type module. Specifications are subject to change without notice. R-NL SPECIFICATIONS ES-88 Rev.9 Page /
MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.
MODEL: R-NL Remote I/O R Series LonWorks INTERFACE MODULE (analog I/O points, discrete I/O 8 points) 7. (.08) 0 (.) 09 (.9) mm (inch) MODEL: R NL [][] ORDERING INFORMATI Code number: R-NL-[][] Specify
More informationR3-NL2 INSTALLATION BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL LONWORKS INTERFACE MODULE MODEL. (I/O 56 points)
INSTRUCTION MANUAL LONWORKS INTERFACE MODULE (I/O 6 points) MODEL R-NL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If
More informationMODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)
MODEL: R-NE Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) 7. (.8) 9 (.9) (.) mm (inch) MODEL: R-NE-[][] ORDERING INFORMATION Code number: R-NE-[][] Specify a code from below for each [] and
More informationR3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)
Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL R-NE MODEL & SUFFIX CODE SELECTION R NE MODEL POWER INPUT K : V AC L : V AC R : V DC N : No power supply * *. Choose N (no power supply)
More informationR3-NL1 LONWORKS INTERFACE MODULE BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL. R3-nL1 MODEL
INSTRUCTION MANUAL LONWORKS INTERFACE MODULE (analog I/O points, discrete I/O 8 points) MODEL R-nL R-NL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you
More informationMODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system
More informationMODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series
Remote I/O R3 Series FL-net INTERFACE MODULE (OPCN-2, Ver.2. supported) Functions & Features FL-net (OPCN-2), Ethernet based, controller level network, compatible remote I/O 1 Mbps/1 Mbps cyclic transmission
More informationMODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable
More informationMODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)
PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to
More informationMODEL: R1M-GH. PC Recorders R1M Series
PC Recorders Series PC RECORDER (thermocouple or DC input, 16 points) Functions & Features Industrial recorder on PC 16-point thermocouple or DC inputs Easy system expansion via Modbus RTU Recorded data
More informationR: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.
Tower Light Series CC-Link TOWER LIGHT (0 mm dia., layers) Functions & Features Lighting, blinking and buzzing are controllable with PLC. Bi-color lighting available in fourth layer Separable tension clamp
More informationMODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)
Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast
More informationMODEL: 47LYV. Digital Panel Meters 47 Series
Digital Panel Meters 47 Series DC INPUT DIGITAL PANEL METER (4 1/2 digit, process meter, LED display type) Functions & Features 4 ½ digit DC input digital panel meter 1/8 DIN size Moving average function
More informationMODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC
MODEL: M1EX 2 Channel Super-mini Signal Conditioners with Display M1E Series SIGNAL TRANSMITTER (2 channels, PC programmable) Functions & Features Converts DC input from a sensor into a standard process
More informationMODEL: WL40EW2F. Wireless I/O WL40F Series
Wireless I/O WL40F Series WIRELESS GATEWAY Modbus/TCP (Ethernet), Modbus-RTU Transparent 900MHz Band Wireless Device (parent device) 60 (2.36) FUTIONS & FEATURES This unit Incorporates 900MHz band wireless
More informationMODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC
2 Channel Super-mini Signal Conditioners with Display M1E Series POTENTIOMETER TRANSMITTER (2 channels, PC programmable) Functions & Features Potentiometer s zero/span points can be captured by onsite
More informationMODEL: R2K-1 SEN TRONIC AG. R2K Series
1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission
More informationMODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series
MODEL: MEXM Super-mini Signal Conditioners with Mini-M ME Series POTENTIOMETER TRANSMITTER (PC programmable) Functions & Features Provides a DC output proportional to a potentiometer or slidewire position
More informationMODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]
Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) 44 (5.67) 7 (.83) * mm (inch) *Selectable with option code /4: 400 mm /6: 600 mm Language blank: Japanese /E: English
More informationMODEL: GR8-EM. Communication Adaptor GR8 Series
Communication Adaptor GR8 Series Ethernet/RS-485 Adaptor (Modbus use) Functions & Features Bidirectional protocol converter for Modbus/TCP (Ethernet) and Modbus RTU (RS-485) Fast response time thanks to
More informationMODEL: 40DN. Digital Panel Meters 40 Series
Digital Panel Meters 40 Series LOOP POWERED DIGITAL PANEL METER (4 digits, process meter) Functions & Features 4 digit (±9999) loop powered panel meter No external power source needed Scaling function
More informationMODEL: 43AL1. Digital Panel Meters 43 Series
Digital Panel Meters 43 Series LOOP POWERED DIGITAL PANEL METER (process meter) Functions & Features Loop powered -1999 to 9999 compact digital meter Scaling function Screwless spring terminal 24 (.94)
More informationMODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White
MODEL: IT0SW Tower Light Series WIRELESS LAN TOWER LIGHT (small size, 0 mm dia., Modbus/TCP, access point, - layers) Functions & Features Lighting, blinking and buzzing available with contact input or
More informationMODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series
Digital Panel Meters 40 Series RTD INPUT DIGITA PANE METER (4 digits, process meter) Functions & Features 4 digit (±9999) panel meter functions igh visible, 0.8" (20.3mm) high and bright ED 48 (1.89) mm
More informationMODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER
Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network
More informationMODEL: M8BS-16. [3] OPTIONS blank: none /Q: With options (specify the specification)
MOEL: M8S-6 ual Output Super-mini Signal onditioners Pico-M Series INSTLLTION SE (6 positions) Functions & Features Holding up to 6 modules of Pico-M series signal conditioners Power supplied through printed
More information73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE
Paperless Recording System PAPERLESS RECORDER (selectable input modules) MODEL & SUFFIX CODE SELECTION MODEL 144 (5.67) MODEL LANGUAGE E : English N : Japanese POWER INPUT M2: 100 240V AC R : 24V DC A
More informationR6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)
INSTRUCTION MANUAL CC-Link INTERFACE MODULE (CC-Link Ver..; for -point analog signals) MODEL R-NC BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received
More informationMODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8
Web Data Logger DL8 WEB-ENABLED REMOTE TERMINAL UNIT Functions and features Remote monitoring of equipment and plants by using modern communication infrastructure Monitoring and logging of a wide variety
More informationR7D-RR8 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, 8 points MODEL. (DeviceNet)
INSTRUCTION MANUAL REMOTE CONTROL RELAY CONTROL MODULE, points (DeviceNet) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined
More informationMODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER
Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network
More informationNEUROLOGIC RESEARCH CORPORATION MODEL 2500
NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication
More informationBEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection)
INSTRUCTION MANUAL PNP TRANSISTOR OUTPUT MODULE, 16 points (MECHATROLINK-I / -II, short circuit protection) R7ML-DC16D MODEL R7ML-DC16D BEFORE USE... Thank you for choosing M-System. Before use, please
More informationR1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)
Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE
More informationCONTENTS 1. BEFORE USE GENERAL DESCRIPTION POINTS OF CAUTION HARDWARE SPECIFICATIONS... 4
INSTRUCTION MANUAL COMMUNICATION CONTROLLER (DeviceNet) MODEL M2BD CONTENTS 1. BEFORE USE... 2 2. GENERAL DESCRIPTION... 2 3. POINTS OF CAUTION... 3 4. HARDWARE SPECIFICATIONS... 4 4.1. M2BD-x1 (suffix
More informationPWR. Power Module Slots
INSTRUCTION MANUAL ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check the contents of the package you received as outlined below. If you
More informationMODEL: CND. Multiplex Transmission System
POW RUN SA1 SA2 MODEL: CND Multiplex Transmission System ADAPTOR CONNECTOR Functions & Features Simplifies wiring wk between multiplex transmission units (DLA1) and 10-RACK, 15-RACK and signal conditioner
More informationR1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)
INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationMODEL: 40DV SEN TRONIC AG. Digital Panel Meters 40 Series
Digital Panel Meters 40 Series DC INPUT DIGIT PNE METER (4 digits, process meter) Functions & Features 4 digit (±9999) panel meter Scaling and functions igh visible, 0.8" (20.3mm) high and bright ED 48
More informationR3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)
INSTRUCTION MANUAL ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have
More informationDAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS
REPETER (SIN-NET, M-us use) MODEL DL MODEL & SUFFIX CODE SELECTION MODEL CLE & PORT TYPE : Twisted-pair cable, ports : Fiber optics (PCF), ports Twisted-pair cable, port 5 : Fiber optics (I-50 nm), port
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More information3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.
2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can
More informationMODEL: MD7TC. Lightning Surge Protectors for Electronics Equipment M-RESTER
MODEL: MDTC Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR THERMOCOUPLE USE (ultra-slim) Functions & Features High discharge current capacity 0 ka ( / 0 μs),
More informationR1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)
INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If
More informationMODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)
Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source
More informationMODEL 1600 FEATURES DESCRIPTION WIRING AND INSTALLATION NETWORK DISPLAY
FEATURES Highly visible fluorescent alphanumeric display able to operate over a temperature range of -40 to 85 C Large 0.43 high numeric display format. 1/8 DIN panel-mount enclosure. Multiple display
More informationMODEL: 43DV2. Digital Panel Meters 43 Series
Digital Panel Meters 43 Series DC INPUT DIGITA PANE METER (process meter) Functions & Features -1999 to +9999 digital panel meter Scaling & old functions available Screwless spring terminal (Input range:
More informationDIO-1616LN-FIT. Features. Specifications. Ethernet Remote I/O F&eIT N Series Isolated Digital Input/Output Unit DIO-1616LN-FIT 1. Ver.1.
Ethernet Remote I/O F&eIT N Series Isolated Digital / DIO-1616LN-FIT * Specifications, color and design of the products are subject to change without notice. This product is an isolated digital input and
More informationMODEL: MD7ST. [3] LOOP DISCONNECT FUSE 0: Without 1: With (CENELEC/ATEX approval Not selectable)
MODEL: MDST Lightning Surge Protectors for Electronics Equipment M-RESTER LIGHTNING SURGE PROTECTOR FOR STANDARD SIGNAL LINE (ultra-slim) Functions & Features High discharge current capacity 0 ka ( / 0μs),
More informationLON-module for MULTICAL 601
LON-module for MULTICAL 601 Type 67-00-24-000-000 i n s t a l l a t i o n Kamstrup A/S Industrivej 28, Stilling, DK-8660 Skanderborg TEL: +45 89 93 10 00 FAX: +45 89 93 10 01 info@kamstrup.com www.kamstrup.com
More informationHITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions
HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction
More informationE4PA. Ultrasonic Displacement Sensor. Ordering Information
Ultrasonic Displacement Sensor Ideal for controlling liquid level. Long sensing distance and high-resolution analog output. High-precision detection with a wide range of measurements Four types of Sensors
More informationTerminal block 2 A 5 X 3. Specification
D Series Features Automatic communication speed recognition : Enables to recognize communication speed automatically when connecting with master Network Voltage monitoring : If PV is lower than SV, enables
More information1201L-1K RTD Controller. Revision 1.1. Nico Technology Ltd. 1 Rev.1.1
1201L-1K RTD Controller Revision 1.1 Nico Technology Ltd. 24F,No.37,SanMin Rd, 2.Sec, PanChiao City, Taipei County, Taiwan Phone +886-2-2954-5338 Fax +886-2-2954-5308 Product Info Thomas@nico-tech.com
More informationCommunications & Networking
8-Point Source Input & 8-Point Transistor Sink Output odule () Key features include: Communicate with network 8-point source input and 8-point sink output module Removable terminal blocks Use as remote
More informationGeneral Specifications
General GS 34M06C01-01E FA-M3 Basic Modules (Base, Power Supply, CPU Modules and ROM Packs) F3BU04-0N, F3BU06-0N, F3BU05-0D, F3BU09-0N, F3BU13-0N, F3BU16-0N F3PU10-0S, F3PU0-0S, F3PU30-0S,
More informationCommunications & Networking
is a type of field bus that is primarily intended to be used to control sensors and actuators. is a network system that is compatible with the IEC62026 standard. A master device can communicate with slave
More informationSYSMAC Remote Transistor Module
9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models
More informationR6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)
INSTRUCTION MANUAL ETHERNET INTERFACE MODULE (Modbus/TCP, for 32-point analog signals) MODEL R6-NE1 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received
More informationOHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L
AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power
More informationTimers. RTE Series. RTE Series Analog Timers. Specifications. G-8 USA: (800) 262-IDEC or (408) , Canada (888) 317-IDEC
Analog Timers Key features of the RTE series include: time ranges and timing functions ON-delay, interval, OFF-delay, one-shot Time delays up to 0 hours Space-saving package (." x." x.0") High repeat accuracy
More informationCommunication & Networking
MicroSmart Master Module Capable of Connecting 62 Slaves Compliance with Ver. 2.1 specifi cations Digital and analog slaves can be connected. Configuration and slave monitoring can be done using LED indicators
More informationSuitable for detecting transparent films or transparent bottles
Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16
More informationEnergy Management Energy Transducer Type ET112
Energy Management Energy Transducer Type Single phase energy transducer Class 1 (kwh according to EN62053-21 Class B (kwh according to EN50470-3 Accuracy ±0.5% RDG (current/voltage Direct current measurement
More informationThread length (overall length) material
Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive
More informationMIC-2 MKII, Multi-instrument DATA SHEET
MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)
More informationPGR-2601 MANUAL DC GROUND-FAULT RELAY
POWR-GARD Ungrounded DC System PGR-2601 SERIES DC Ground-Fault Relay PGR-2601 MANUAL DC GROUND-FAULT RELAY AUGUST 31, 2009 REVISION 1 POWR-GARD DC GROUND-FAULT RELAY PWR TRIP 5 4 3 2 6 - BUS 8 10 15 20
More informationDLS-E2 TELEMETERING UNIT BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL MODEL. (16 contact inputs & 16 open collector outputs)
INSTRUCTION MANUAL TELEMETERING UNIT ( contact inputs & open collector outputs) MODEL DLS-qE DLS-E BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received
More informationCTR21, CTR22, CTR23, and CTR24 Wall Modules
CTR21, CTR22, CTR23, and CTR24 Wall Modules FEATURES SPECIFICATION DATA The CTR21, CTR22, CTR23, and CTR24 family of wall modules include: Models with setpoint adjustment. Models with occupied/unoccupied
More informationOTB1C0DM9LP I/O distributed module OTB - CANopen bus m
Characteristics I/O distributed module OTB - CANopen bus - 0..1000 m Main Range of product Product or component type Integrated connection type Bus type Jan 28, 2018 Modicon OTB I/O distributed module
More informationUNT1100 Series. Binary Output Jumpers AO2 AO1 AO3 AO4 AOCM AOCM AOCM AOCM AO1. AI Switches Job Information N2 Address. Ref N2+ N2- ADDR 0 = ALL OPEN
1 2 8 4 AI6 R R Installation Bulletin UNT1100 Issue Date 0309 UNT1100 Series Introduction The Unitary (UNT) controller (UNT1100 Series) is a digital controller with applications for air handling units,
More informationOTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m
Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Product availability : Stock - Normally stocked in distribution facility Price* : 494.00 USD Main Range of product
More informationCommunication Controller CC-Link/CPL Converter CMC10A
No. CP SS 1766E Communication Controller CC-Link/CPL Converter CMC10A The communication controller CMC10A is a converter designed for the communication between Yamatake's digital indicating controller
More informationOTB1S0DM9LP I/O distributed module OTB - Modbus non isolated serial link m
Characteristics I/O distributed module OTB - Modbus non isolated serial link - 0..10 m Complementary Topology Bus length Main Number of devices per segment 0...32 Data format Parity Discrete input voltage
More informationSolving your relay requirements since 1922
Expected Life @ 25 C: 100,000 operations minimum at rated loads Solving your relay requirements since 1922 C Series TDR Solid state analog circuitry Delay on operate timing mode Compact size Relay output
More informationIO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs
IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,
More informationOTB1C0DM9LP. Main , length of segment <= 185 m , length of segment <= 160 m. 3.4 kohm for I8...I kohm I0...I1 5.7 kohm I6...
Product datasheet Characteristics OTB1C0DM9LP Complementary Topology Number of slave 63 Bus length Number of devices per segment Discrete input voltage Discrete input voltage type Discrete input type Input
More informationMICREX-SX Series Renewal Tool Announcement of Release of MICREX-F Size I/O Module
Dear Customers, January 2016 Fuji Electric Co., Ltd. MICREX-SX Series Renewal Tool Announcement of Release of MICREX-F Size I/O Module Thank you for using the Fuji programmable controller. We hereby announce
More informationVisualize the actual worksite status! Simple and Intelligent I/O Slave Units.
Digital I/O Slave Units with Screw Terminal Blocks (2-tier Terminal Block/Relay Output/SSR Output) CRT1-@D(-1)/@D(-1)/ROS@/ROF@ Visualize the actual worksite status! Simple and Intelligent I/O Slave Units.
More informationInductive Proximity Sensor
Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.
More informationWeb-enabled DAQ System
2016-09 EC-8631 500479 6-0001 Rev.0 01 Web-enabled DAQ System Model: TR30-G High Speed Sampling 5 ms/ai 16 points HTTP server Modbus/TCP master and slave Trigger recording FTP client and server E-mailing
More informationPGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY
Tel: +1-800-832-3873 E-mail: techline@littelfuse.com www.littelfuse.com PGR-4300 MANUAL GENERATOR GROUND-FAULT RELAY REVISION 3-B-041318 Copyright 2018 by Littelfuse, Inc. All rights reserved. Document
More informationTABLE OF CONTENTS. Communication Functions
TABLE OF CONTENTS Chapter 1: Chapter 2: Chapter 3: Chapter 4: General Features....................................................... 1-1 Functions......................................................
More informationIndustrial Control Relays Relays and terminal module RS type
Relaysandterminal module Relays-and-terminal module RS, N A very compact, space-saving terminal module containing four or six relays with one NO contact. Features The RS series relays-and-terminal module
More informationDIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E
INSTALLATION MANUAL DIGITAL INPUT/OUTPUT RELAY INTERFACE BMS-IFDD01E Thank you very much for purchasing this TOSHIBA Digital Input/Output Relay Interface. Please read this manual carefully beforehand for
More informationPRCMT18-5DO PRCMT18-5DC PRCMT18-5DO-I PRCMT18-5DC-I
PRCM Series Cylindrical Connector Type Proximity Sensor Features Improved the noise immunity with dedicated IC Built-in reverse polarity protection circuit (DC -wire type) Built-in surge protection circuit
More informationTimers. GT3W Series Dual Time Range Timers. 250V AC/150V DC Time Range. 1: 0.1sec to 6 hours, 3: 0.1sec to 300 hours
GT3W Key features: Sequential start, sequential interval, on-delay, recycler, and interval ON timing functions 2 time settings in one timer 8 selectable operation modes on each model Mountable in sockets
More information4. Sensing Distance. 2: 2 mm. 4: 4 mm 8: 8 mm 15: 15 mm 16: 16 mm 20: 20 mm
Inductive Sensor Double Sensing Distance Model Number Legend SALIENT FEATURES IP - 7, Brass Housing Short - Circuit protection Reverse Polarity Protection Shielded and Non - Shielded Prewired and Connector
More informationEnergy Management Modular DC Energy analyzer Type VMU-E and VMU-X
Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.
More informationPC RELAY TERMINAL/ PC TERMINAL
Input points Output points PC Relay (PC relays mounted) PC Input points Output points Input points Output points Input points Output points Input points Output points Output points ORDERING INFORMATION
More informationEnergy Management Modular DC Energy analyzer Type VIM-E and VIM-X
Energy Management Modular DC Energy analyzer Type VIM-E and VIM-X Modular solution based on the combination of two units: VIM-E analysis unit and VIM-X universal power supply and RS485 communication unit.
More information7-4-2 CP1W-MAD11/CPM1A-MAD11 Analog I/O Units
7-4-2 CP1W-MAD11/CPM1A-MAD11 I/O Units Part Names CP1W-MAD11/CPM1A-MAD11 Each CP1W-MAD11/CPM1A-MAD11 I/O Unit provides 2 analog inputs and 1 analog output. The analog input range can be set to 0 to 5 VDC,
More informationMeasurement Systems Datascan Installation and User Guide
Measurement Systems Datascan Installation and User Guide Supplied By Contents Contents 1. INTRODUCTION... 1 1.1 GENERAL... 1 1.2 DATASCAN MODULE RANGE... 1 1.2.1 Measurement Processors... 1 1.2.2 Analog
More informationProgrammable Relay ZEN V2 Units
Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty
More informationThread length. 27 (40) mm. 27 (44) mm. 27 (40) mm. 34 (50) mm. 34 (49) mm. 39 (60) mm. 39 (54) mm. 44 (65) mm. 44 (59) mm
Long Distance Cylindrical. Extra long for increased protection and sensing performance triple proximity sensors for flush mounting requirements. designed and tested for extra long life. Ordering Information
More informationMini Photoelectric Sensor
Mini Photoelectric Sensor High cost-performance Mini Photoelectric Sensor Saves Installation Space and Wiring Effort and Detects Minute Sensing Objects Pin-point beam (1 to 2-mm dia.) makes it possible
More informationOTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m
Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete
More informationFunctional data Nominal torque min. 180 in lb [20 NM] Communicative control Cloud: (call for clientapi )
Cloud capable and communicating failsafe damper actuator for adjusting dampers in commercial HVAC applications. Failsafe Air Damper Size Up to approx. 45 sq. ft. Nominal Torque 180 in lb [20 NM] Power
More informationSafety Control. FS1A Multi-function Safety Relay. Optional Parts. Connecting Tool. Marked Cable Tie. DIN Rail BNDN1000 Aluminum, 1m 35mm wide
Multi-function Relay Key features: No programming required. Configuration complete by turning on a logic switch A safety circuit can be configured easily just by selecting a logic from eight preprogrammed