MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White

Size: px
Start display at page:

Download "MODEL: IT40SW2. Tower Light Series. [2] LAMP 1 COLOR (1st layer from the top) R: Red Y: Amber G: Green B: Blue W: White"

Transcription

1 MODEL: IT0SW Tower Light Series WIRELESS LAN TOWER LIGHT (small size, 0 mm dia., Modbus/TCP, access point, - layers) Functions & Features Lighting, blinking and buzzing available with contact input or PC via Modbus/TCP. status acquisition available through wireless LAN. Connection to network with bridge function, in remote I/O Ethernet type via wireless LAN. LAN access point complied with IEEE80.b/g/n Nondirectional antenna (60 horizontal) Client use is available by mode change. Conforming to Electronic Communications Act, 00 of the Republic of South Africa 88 (.7) A [] LAMP COLOR (st layer from the top) [] LAMP COLOR (nd layer from the top) N: None (not available when Lamp Layers selected are - ) [] LAMP COLOR (rd layer from the top) N: None (not available when Lamp Layers selected are - ) mm (inch.) Lamp Layers 60 (.6) A (8.8) 6 (0.08) 88 (.) 0 (.60) (.86) MODEL: IT0SW-[][][][][][6]D-R[7] ORDERING INFORMATION Code number: IT0SW-[][][][][][6]D-R[7] Specify a code from below for each [] through [7]. (e.g. IT0SW-RYGBWD-R/ZA) [] LAMP LAYERS : layer : layers : layers : layers : layers [] LAMP COLOR (th layer from the top) N: None (not available when Lamp Layers selected are - ) [6] LAMP COLOR N: None (not available when Lamp Layers selected are ) * The selection of the same color for more than one layer is not available. * Select "None" option for the layers other than the selected. MOUNTING D: Direct mounting IT0SW SPECIFICATIONS ES-86 Rev.8 Page /6

2 MODEL: IT0SW DESIGN TYPE : Type (refer to outline dimensions) POWER INPUT DC Power R: V DC (Operational voltage range V ±0 %, ripple 0 %p-p max.) [7] COUNTRY blank: Japan, EU /ZA: South African Republic RELATED PRODUCTS LAN cable (model: ITCA) Mounting Pole (model: ITPL) PC configurator software (model: ITCFG) Functions are configurable using the PC Configurator Software. Downloadable at M-System s web site. GENERAL SPECIFICATIONS Degree of protection: IP 6, vertical mounting only (bottom connectors excluded) Connection Power: UL007 AWG0 Input: UL007 AWG Ethernet: RJ- Modular Jack Housing material: Flame-resistant resin Lens: Flame-resistant resin (transparent) Isolation: Discrete input or power input to network DIP SW Setting: Frequency of lamp blinking and buzzing discontinuance, buzzing volume level, output at connection failed and IP address (refer to the instruction manual) Lamp: Red, amber, green, blue and white LEDs on/blinking (approx. Hz, 0 Hz) Indicator LEDs: Power, Run (Refer to the insruction manual) Buzzing: Approx.. khz Interval: continuous/intermittent (approx. Hz, 0 Hz) COMMUNICATION Common spec. Modbus protocol Protocol: Modbus/TCP Data: RTU (Binary) Port No.: 0 Max. number of socket connections: 0 DHCP protocl: DHCP server IP address: (factory setting); Selectable with PC Configurator Software (model: ITCFG) Ethernet Communication Standard: IEEE 80.u Transmission: 0BASE-T, 00BASE-TX Baud rate: 0/00 Mbps (Auto Negotiation function) Transmission media: 0BASE-T (STP, Category ) 00BASE- TX (STP, Category e) Max. length of fieldbus segment: 00 meters IP address: (factory setting); Selectable with PC Configurator Software Ethernet indicator LED: Link, Link00, COL LAN Communication Standard: IEEE 80.b/g/n Frequency range: MHz (ch - ch) Max. transmision distance (optical): Approx. 0m (depends on setting) Access mode: infrastructure Security: WEP 6bit/8bit, WPA (TKIP, AES), WPA (TKIP, AES) LAN indicator: WLAN Number of clients: INPUT SPECIFICATIONS Discrete Input: Dry contact, open collector NPN Input resistance: Approx.. kω Common: Negative common NPN ON level: V /. ma (Input - COM) OFF level: 8 V DC / ma (Input - COM) Input current:. ma per V DC INSTALLATION Power consumption DC: Approx.. W Operating temperature: -0 to + C ( to F) Operating humidity: 0 to 8 %RH (non-condensing) Atmosphere: No corrosive gas Mounting: Direct mounting Mounting direction: Vertical Weight: Approx. 60 g (. lb) PERFORMANCE Insulation resistance: 00 MΩ with 00 V DC Dielectric strength: 00 V minute (discrete input or power to network IT0SW SPECIFICATIONS ES-86 Rev.8 Page /6

3 MODEL: IT0SW STANDARDS & APPROVALS Built-in module certified under Japanese Radio Law EU conformity: RE Directive EN 00 8 V.. RoHS Directive EN 08 EN V.9. EN Certified under Electronic Communications Act, 00 of ICASA (Independent Communications Authority of South Africa) EXTERNAL VIEW FRONT VIEW (with the cover open) BOTTOM VIEW Lamp Lamp Lamp Power Link COL WLAN Run Link00 WLAN FRONT Lamp Mode Ethernet Modular Jack Status Indicator LED Power Link COLWLAN Run Link00WLAN DIP SW Antenna IP Address Reset Buzzer Aperture Gasket IT0SW SPECIFICATIONS ES-86 Rev.8 Page /6

4 MODEL: IT0SW DIMENSIONS unit: mm 0±.dia. A± Control Panel Cover R77. 6 lengths* (8) Lamp Layers A Bolts and Nuts (M) (8) Approx.00 ±. dia. Lead wires (0 dia.) *. Consult M-System for other bolt length. MOUNTING REQUIREMENTS unit: mm Wiring Hole 0 dia.* dia. Holes ( dia.) 0 Front *Protect wires to prevent scratching them at the edge of the compartment. IT0SW SPECIFICATIONS ES-86 Rev.8 Page /6

5 MODEL: IT0SW SCHEMATIC CIRCUITRY & CONNECTION DIAGRAM Antenna Connector Comm. LAMP BUZZER To other Ethernet devices LAMP INPUT Red RJ- JACK LAMP * Isolation Comm. STAUS IND. LED DIP SW LAMP INPUT LAMP INPUT LAMP INPUT Yellow Green Blue LAMP * LAMP * LAMP * Control IP ADDR. RESET SW INPUT LAMP INPUT White LAMP * Input BUZZER INPUT Continuance Purple BUZZER BUZZER INPUT Discontinuance Cyan BUZZER LAMP COM Brown POWER Gray Black + /COM Power *. Example of layers in order: red, yellow, green, blue and white. Lamp and wire color are the same. WIRING TO INPUT SIGNAL e.g. NPN input e.g. ON TOWER LIGHT LAMP LAMP ON TOWER LIGHT LAMP LAMP LAMP LAMP LAMP LAMP LAMP LAMP BUZZER BUZZER BUZZER BUZZER + + /COM /COM Note : If On (Continuous) and Blink (Intermittent) are set simultaneously for a single lamp (buzzer), Blink (Intermittent) is disabled. The same procedure will be applyed also for the others lamps. IT0SW SPECIFICATIONS ES-86 Rev.8 Page /6

6 MODEL: IT0SW SYSTEM CONFIGURATION EXAMPLES EXAMPLE. Activate the tower light lamp and buzzer with contact input.. Aquire data of contact status of tower light lamp with PC. IT0SW Communication IT0SW ITxSW PC IT60SW EXAMPLE. Activate the tower light lamp and buzzer with PC. Communication IT0SW PC ITxSW Communication EXAMPLE. Activate the tower light lamp and buzzer with PC.. Interchange data between PC and Remote I/O. IT0SW PC Comm. ITxSW IT60SW Remote I/O Contact status of tower light described on example is also available while interchanging data with PC. Client is available with ITxSW. Specifications are subject to change without notice. IT0SW SPECIFICATIONS ES-86 Rev.8 Page 6/6

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White.

R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. R: Red Y: Amber G: Green B: Blue W: White. Tower Light Series CC-Link TOWER LIGHT (0 mm dia., layers) Functions & Features Lighting, blinking and buzzing are controllable with PLC. Bi-color lighting available in fourth layer Separable tension clamp

More information

MODEL: WL40EW2F. Wireless I/O WL40F Series

MODEL: WL40EW2F. Wireless I/O WL40F Series Wireless I/O WL40F Series WIRELESS GATEWAY Modbus/TCP (Ethernet), Modbus-RTU Transparent 900MHz Band Wireless Device (parent device) 60 (2.36) FUTIONS & FEATURES This unit Incorporates 900MHz band wireless

More information

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08)

MODEL: R3-NE1. Remote I/O R3 Series. ETHERNET INTERFACE MODULE (Modbus/TCP) 27.5 (1.08) MODEL: R-NE Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) 7. (.8) 9 (.9) (.) mm (inch) MODEL: R-NE-[][] ORDERING INFORMATION Code number: R-NE-[][] Specify a code from below for each [] and

More information

MODEL: GR8-EM. Communication Adaptor GR8 Series

MODEL: GR8-EM. Communication Adaptor GR8 Series Communication Adaptor GR8 Series Ethernet/RS-485 Adaptor (Modbus use) Functions & Features Bidirectional protocol converter for Modbus/TCP (Ethernet) and Modbus RTU (RS-485) Fast response time thanks to

More information

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-D1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact output, 32 points) Functions & Features Industrial recorder on PC 32-point open collector outputs Easy system expansion via Modbus RTU Recorded data exportable

More information

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP)

R3-NE1 ETHERNET INTERFACE MODULE MODEL. Remote I/O R3 Series. (Modbus/TCP) Remote I/O R Series ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL R-NE MODEL & SUFFIX CODE SELECTION R NE MODEL POWER INPUT K : V AC L : V AC R : V DC N : No power supply * *. Choose N (no power supply)

More information

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-A1. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders R1M Series PC RECORDER (contact input, 32 points) Functions & Features Industrial recorder on PC 32-point dry contact inputs Easy system expansion via Modbus RTU Recorded data exportable to

More information

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.)

MODEL: R1M-P4. PC Recorders R1M Series. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) PC Recorders Series PC RECORDER (4 totalized counter inputs, 8 contact inputs and outputs) Functions & Features Industrial recorder on PC Totalized counter inputs Counts stored in E 2 PROM Easy system

More information

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series

MODEL: R3-NFL1. SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) Remote I/O R3 Series Remote I/O R3 Series FL-net INTERFACE MODULE (OPCN-2, Ver.2. supported) Functions & Features FL-net (OPCN-2), Ethernet based, controller level network, compatible remote I/O 1 Mbps/1 Mbps cyclic transmission

More information

MODEL: R1M-GH. PC Recorders R1M Series

MODEL: R1M-GH. PC Recorders R1M Series PC Recorders Series PC RECORDER (thermocouple or DC input, 16 points) Functions & Features Industrial recorder on PC 16-point thermocouple or DC inputs Easy system expansion via Modbus RTU Recorded data

More information

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series

MODEL: M2EXM. Super-mini Signal Conditioners with Display Mini-M M2E Series MODEL: MEXM Super-mini Signal Conditioners with Mini-M ME Series POTENTIOMETER TRANSMITTER (PC programmable) Functions & Features Provides a DC output proportional to a potentiometer or slidewire position

More information

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M1EXV. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC MODEL: M1EX 2 Channel Super-mini Signal Conditioners with Display M1E Series SIGNAL TRANSMITTER (2 channels, PC programmable) Functions & Features Converts DC input from a sensor into a standard process

More information

MODEL: R2K-1 SEN TRONIC AG. R2K Series

MODEL: R2K-1 SEN TRONIC AG. R2K Series 1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission

More information

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC

MODEL: M1EXM. OUTPUT Field-selectable DC Output Current output: 0-20 ma DC Voltage output: V DC Voltage output: V DC 2 Channel Super-mini Signal Conditioners with Display M1E Series POTENTIOMETER TRANSMITTER (2 channels, PC programmable) Functions & Features Potentiometer s zero/span points can be captured by onsite

More information

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions

ICP DAS. ICP DAS 2015 M2M WLAN Wireless Solutions ICP DAS 2015 M2M WLAN Wireless Solutions Industrial Computer Industrial Product Data Computer Acquisition Product System Data Acquisition System PAC WLAN Wireless Solutions Wi-Fi Products WLAN Converter

More information

MODEL: 47LYV. Digital Panel Meters 47 Series

MODEL: 47LYV. Digital Panel Meters 47 Series Digital Panel Meters 47 Series DC INPUT DIGITAL PANEL METER (4 1/2 digit, process meter, LED display type) Functions & Features 4 ½ digit DC input digital panel meter 1/8 DIN size Moving average function

More information

MODEL: 43AL1. Digital Panel Meters 43 Series

MODEL: 43AL1. Digital Panel Meters 43 Series Digital Panel Meters 43 Series LOOP POWERED DIGITAL PANEL METER (process meter) Functions & Features Loop powered -1999 to 9999 compact digital meter Scaling function Screwless spring terminal 24 (.94)

More information

MODEL: 40DN. Digital Panel Meters 40 Series

MODEL: 40DN. Digital Panel Meters 40 Series Digital Panel Meters 40 Series LOOP POWERED DIGITAL PANEL METER (4 digits, process meter) Functions & Features 4 digit (±9999) loop powered panel meter No external power source needed Scaling function

More information

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network

More information

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: R3-NL1. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker. MODEL: R-NL Remote I/O R Series LonWorks INTERFACE MODULE (analog I/O points, discrete I/O 8 points) 7. (.08) 0 (.) 09 (.9) mm (inch) MODEL: R NL [][] ORDERING INFORMATI Code number: R-NL-[][] Specify

More information

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER

MODEL: MDCAT. Lightning Surge Protectors for Electronics Equipment M-RESTER Lightning Surge Protectors for Electronics Equipment M-RESTER LIHTNIN SURE PROTECTOR FOR ETHERNET (PoE / 10 BASE-T / 100 BASE-TX / 1000 BASE-T) Functions & Features Designed specifically for Ethernet network

More information

MODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8

MODEL: DL8. POWER INPUT DC power R: 24 V DC (Operational voltage range: ±10 %; ripple 10 %p-p max.) Web Data Logger DL8 Web Data Logger DL8 WEB-ENABLED REMOTE TERMINAL UNIT Functions and features Remote monitoring of equipment and plants by using modern communication infrastructure Monitoring and logging of a wide variety

More information

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast

More information

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points)

R1M-GH THERMOCOUPLE & DC INPUT MODULE MODEL. Remote I/O R1M Series. (16 points) Remote I/O R1M Series THERMOCOUPLE & DC INPUT MODULE (16 points) MODEL MODEL & SUFFIX CODE SELECTION R1MGH2T MODEL Modbus protocol I/O TYPE GH2 : Thermocouple or DC input, 16 points FIELD TERMINAL TYPE

More information

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker.

MODEL: R3-NL2. RELATED PRODUCTS XIF File (Device Interface File) XIF file is used to define a LonWorks device when programmed on LonMaker. MODEL: R-NL Remote I/O R Series LonWorks INTERFACE MODULE (I/O points) 7. (.08) 0 (.) 09 (.9) mm (inch) MODEL: R NL [][] ORDERING INFORMATION Code number: R-NL-[][] Specify a code from below for each []

More information

MW5501C Series MW5502C Series. 1 or 2-Port Industrial Wireless Modbus TCP/RTU/ASCII Gateway FEATURE HIGHLIGHTS PRODUCT DESCRIPTION

MW5501C Series MW5502C Series. 1 or 2-Port Industrial Wireless Modbus TCP/RTU/ASCII Gateway FEATURE HIGHLIGHTS PRODUCT DESCRIPTION MW550C Series MW550C Series or -Port Industrial Wireless Modbus TCP/RTU/ASCII Gateway FEATURE HIGHLIGHTS Designed for 80. b/g/n networks, FCC (USA), ETSI (Europe) certified x 00BaseT(X) RJ45 port, and

More information

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range.

3-step setting 2. 2-Color Display High-Precision Digital Pressure Switch. ZSE30A(F)/ISE30A Series. Added vacuum range. 2-Color Display High-Precision Digital Pressure Switch ZSE3A(F)/E3A Series RoHS Can copy to up to 1 switches simultaneously. setting labor Minimizing ZSE3 E3 ZSE4 E4 The settings of the master sensor can

More information

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3]

MODEL: SC100. Single Loop Controller Series. MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) MODEL: SC100 [1]0 [2][3] Single Loop Controller Series MULTI-FUNCTION PID CONTROLLER (color LCD with touch-panel) 44 (5.67) 7 (.83) * mm (inch) *Selectable with option code /4: 400 mm /6: 600 mm Language blank: Japanese /E: English

More information

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP)

R3-GE1 BEFORE USE... INSTALLATION POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP) INSTRUCTION MANUAL ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If you have

More information

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m.

E3S-A. Built-in Amplifier Photoelectric Sensor (Medium Size) Ordering Information. Built-in Amplifier Photoelectric Sensors. Horizontal. 7 m. Built-in Amplifier (Medium Size) ES-A Be sure to read Safety Precautions on page 0. Ordering Information Built-in Amplifier s Red light Infrared light Sensing method Appearance Connection method Sensing

More information

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m)

Light ON 5m. * Light ON. 2.5m (3m) Light ON. (5m) All voltage photoelectric sensors Built-in amplifier accepts wide supply voltage range. Slim, space-saving construction measures only x x 7.4 mm. s with long life expectancy and high switching capacity

More information

elettriche DataSheet Zeus Link_Wi-Fi_EN

elettriche DataSheet Zeus Link_Wi-Fi_EN Zeus Link Wi-Fi Wireless AP Bridge/Client/Router 230 Vac Power supply Small footprint: 1 DIN module only Fast Ethernet Interface USB 2.0 Mass storage interface to connect external 3G modem Firmware upgradable

More information

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are

G9SA. Ordering Information. Safety Relay Unit. The G9SA Series Offers a Complete Line of Compact Units. H Several types of 45-mm wide Units are Safety Relay Unit The G9SA Series Offers a Complete Line of Compact Units H Several types of -mm wide Units are available: a -pole model, a -pole model, models with poles and OFF-delay poles H 7.-mm wide

More information

Multiple Solutions in One Device

Multiple Solutions in One Device High-Power Wireless AC600 Dual-Band Outdoor Access Point and Repeater 433 Mbps Wireless AC (5 GHz) + 150 Mbps Wireless N (2.4 GHz), IP65, 28 dbm, Wireless Client Isolation, Passive PoE, Wall- and Pole-mount

More information

PWR. Power Module Slots

PWR. Power Module Slots INSTRUCTION MANUAL ETHERNET INTERFACE MODULE (Modbus/TCP) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check the contents of the package you received as outlined below. If you

More information

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1

E2A. Ordering Information. Cylindrical Proximity Sensor. Safe Mounting with Greater Sensing Distance. E2A Cylindrical Proximity Sensor 1 Cylindrical Proximity Sensor E2A Safe Mounting with Greater Sensing Distance Ensures a sensing distance approximately 1. to 2 times larger than that of any conventional OMRON Sensor. Problems such as the

More information

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.

A16. Separate Construction with Cylindrical 16-dia. Body. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia. Pushbutton Switch (Detachable) (Lighted/Non-Lighted) (Cylindrical 16-dia.) Separate Construction with Cylindrical 16-dia. Body Miniature design of 28.5 mm, the smallest class in the industry. Detachable

More information

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series

MODEL: 40DR SEN TRONIC AG. Digital Panel Meters 40 Series Digital Panel Meters 40 Series RTD INPUT DIGITA PANE METER (4 digits, process meter) Functions & Features 4 digit (±9999) panel meter functions igh visible, 0.8" (20.3mm) high and bright ED 48 (1.89) mm

More information

General Specifications

General Specifications General Specifications LN90 Interface Adapter GENERAL This General Specification (GS) describes the specification for Interface Adapter. This product is a RS-485 signal relay and power supply for the Field

More information

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC

Installation Sensing distance Connection Output configuration Operation mode NO Operation mode NC Standard (thin shape) Inductive Proximity Sensor Thin shape for space saving surface mounting Direct side wall mounting for bracket-less installation Ordering Information DC 3-wire Models Installation

More information

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections.

Designed for commercial, residential and industrial applications, guarantee rapid installation with few and easy connections. Gateways from M-Bus/wM-Bus to Modbus TCP/IP Benefits SIU-MBMs are gateways that transform data from the M-Bus and wireless M-Bus protocol into the Modbus TCP/IP protocol, to then send them to a master.

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Miniature, Slim-styled Proximity Sensor Space-saving Sensor ideal for timing cam and dog detection. Four mounting holes provided: two each mounting from side or rear of the housing.

More information

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations

Slim Relay G2RV. Model Number Structure. Ordering Information. Model Number Legend. List of Models. Relay and Socket Combinations Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Transparent housing enables checking relay

More information

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing

Oil-resistive, Long-range Photoelectric Sensor with Metal Housing Oil-resistive, Long-range with Metal Housing ES-C Water- and Oil-resistive with Metal Housing Used for Long-range Sensing Satisfies the water- and oil-resistive requirements and safe enough for use in

More information

E4PA. Ultrasonic Displacement Sensor. Ordering Information

E4PA. Ultrasonic Displacement Sensor. Ordering Information Ultrasonic Displacement Sensor Ideal for controlling liquid level. Long sensing distance and high-resolution analog output. High-precision detection with a wide range of measurements Four types of Sensors

More information

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter

Option 2. Nil. Note 1) Option 1. Note With waterproof seal and mounting screw. With waterproof seal and mounting screw. 48 conversion adapter Series 0-PSE00 RoHS Remote Type Multi-Channel Digital Pressure Sensor Controller How to Order Clean series 0 PSE0 0 M Input/Output specifications 0 NPN 5 outputs + Auto shift input PNP 5 outputs + Auto

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Main Range of product Product or component type Integrated connection type Mar 31, 2018 Modicon OTB I/O distributed module Discrete

More information

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS

DAL4 REPEATER MODEL. (SIN-NET, M-Bus use) MODEL & SUFFIX CODE SELECTION DAL4 TRANSMISSION ORDERING INFORMATION RELATED PRODUCTS GENERAL SPECIFICATIONS REPETER (SIN-NET, M-us use) MODEL DL MODEL & SUFFIX CODE SELECTION MODEL CLE & PORT TYPE : Twisted-pair cable, ports : Fiber optics (PCF), ports Twisted-pair cable, port 5 : Fiber optics (I-50 nm), port

More information

DMT345 and DMT346 Dewpoint Transmitters

DMT345 and DMT346 Dewpoint Transmitters DMT345 and DMT346 Dewpoint Transmitters for High Temperature Applications Features DMT345 measures humidity at temperatures up to 180 C (356 F) DMT346 measures humidity at temperatures up to 350 C (+662

More information

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System

Advant OCS. The Compact and Cost Effective Advant Controller. Advant Controller 210. Open Control System Advant OCS Open Control System Advant Controller 210 The Compact and Cost Effective Advant Controller Advant Controller 210 is a small, cost-effective system belonging to the Advant Controller family.

More information

MODEL: CND. Multiplex Transmission System

MODEL: CND. Multiplex Transmission System POW RUN SA1 SA2 MODEL: CND Multiplex Transmission System ADAPTOR CONNECTOR Functions & Features Simplifies wiring wk between multiplex transmission units (DLA1) and 10-RACK, 15-RACK and signal conditioner

More information

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible

Main contacts Auxiliary contact Number of input channels Rated voltage Model Category 24 VAC/VDC 3PST-NO SPST-NC 1 channel or 2 channels possible Safety Relay Unit Four kinds of -mm wide Units are available: A -safety contact model, a -safety contact model, and models with safety contacts and OFF-delay safety contacts. Also available are 7.-mm wide

More information

Inductive Proximity Sensor

Inductive Proximity Sensor Inductive Proximity Sensor Subminiature Sensor with Cable Amplifier Offers Greater Mounting Flexibility Programmable Controller-compatible Subminiature, shielded sensing head (3 or 8 dia.) allows the Sensor

More information

Web-enabled DAQ System

Web-enabled DAQ System 2016-09 EC-8631 500479 6-0001 Rev.0 01 Web-enabled DAQ System Model: TR30-G High Speed Sampling 5 ms/ai 16 points HTTP server Modbus/TCP master and slave Trigger recording FTP client and server E-mailing

More information

EIS-EXTEND-C-EU. Ethernet Coaxial Extender for 10/100 Networks. Extend Ethernet Coaxial Connections Up to 8530 Feet

EIS-EXTEND-C-EU. Ethernet Coaxial Extender for 10/100 Networks. Extend Ethernet Coaxial Connections Up to 8530 Feet Features EIS-EXTEND-C EIS-EXTEND-C-5009-ds - 1/4 Ethernet Coaxial Extender for 10/100 Networks Functional Description The model EIS-EXTEND-C allows your existing coaxial cable to be used to extend Ethernet

More information

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m

OTB1E0DM9LP I/O distributed module OTB - Ethernet TCP/IP m Characteristics I/O distributed module OTB - Ethernet TCP/IP - 0..100 m Complementary Concept Port Ethernet Bus length Main Number of devices per segment 0...256 Communication service Web services Discrete

More information

JetWave IEEE802.11a and b/g Wireless Outdoor AP/Bridge. Installation. Wireless Outdoor AP. RoHS LAN 1 LAN 2

JetWave IEEE802.11a and b/g Wireless Outdoor AP/Bridge. Installation. Wireless Outdoor AP. RoHS LAN 1 LAN 2 JetWave 2640 IEEE802.11a and 802.11b/g Wireless Outdoor AP/Bridge RoHS Support both IEEE 802.11a and 802.11b/g with maximum net data rate of 54 Mbps High Gain 23dbi Panel Antenna maximizes transmission

More information

must Operate Voltage (V)

must Operate Voltage (V) force-guided relays g7sa G7SA compact, Slim relays conforming to en Standards Relays with forcibly guided contacts (EN50205 Class A, certifi ed by VDE) Supports the CE marking of machinery (Machinery Directive)

More information

IAP-320 series are reliable a/b/g WLAN Access Point with 2 ports LAN. It supports 802.1X and MAC filters for

IAP-320 series are reliable a/b/g WLAN Access Point with 2 ports LAN. It supports 802.1X and MAC filters for IAP-320 / IAP-320+ Industrial IEEE 802.11 a/b/g wireless access point with 2x10/100Base-T(X) Features High Speed Air Connectivity: WLAN interface support up to 54Mbps link speed Highly Security Capability:

More information

Safety Relay Unit (I/O Unit Type)

Safety Relay Unit (I/O Unit Type) Safety Relay Unit (I/O Unit Type) CQM1-SF200/ CS1W-SF200 Same Dimensions as I/O Unit Less Installation Space and Wiring Required Safety Relay Unit that can be used as an I/O Unit for OMRON s CQM1H and

More information

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals)

R6-NE1 BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL ETHERNET INTERFACE MODULE MODEL. (Modbus/TCP, for 32-point analog signals) INSTRUCTION MANUAL ETHERNET INTERFACE MODULE (Modbus/TCP, for 32-point analog signals) MODEL R6-NE1 BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received

More information

MODEL: 43DV2. Digital Panel Meters 43 Series

MODEL: 43DV2. Digital Panel Meters 43 Series Digital Panel Meters 43 Series DC INPUT DIGITA PANE METER (process meter) Functions & Features -1999 to +9999 digital panel meter Scaling & old functions available Screwless spring terminal (Input range:

More information

MIC-2 MKII, Multi-instrument DATA SHEET

MIC-2 MKII, Multi-instrument DATA SHEET MIC-2 MKII, Multi-instrument DATA SHEET Measurements All 3-phase AC measurements True RMS 4-Quadrant energy Power Quality Analysis Replaces analogue meters RS-485 Modbus RTU protocol TCP/IP Modbus (optional)

More information

Industrial IEEE b/g/n wireless access point with 2x10/100Base-T(X) Features

Industrial IEEE b/g/n wireless access point with 2x10/100Base-T(X) Features IAP-420 / IAP-420+ Industrial IEEE 802.11 b/g/n wireless access point with 2x10/100Base-T(X) Features High Speed Air Connectivity: WLAN interface support up to 150 Mbps link speed Highly Security Capability:

More information

128MB non-volatile flash memory; unlimited storage via remote network device.

128MB non-volatile flash memory; unlimited storage via remote network device. The following sections list general specifications for the In-Sight Micro vision systems. In-Sight Micro Vision System Specifications Table 3-1: In-Sight Micro Vision System Specifications Specifications

More information

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR

Operation mode. Output configuration. Relay DC SSR. Light-ON Dark-ON (switch selectable) Relay DC SSR. Relay DC SSR Built-in Power Supply Photoelectric Sensor CSM DS_E_12_3 Model Contribute to Overall Cost Reduction erminal Block Models Easy to wire and adjust. For the most recent information on models that have been

More information

JetWave IEEE802.11a Wireless Outdoor AP/Bridge. Installation. Wireless Outdoor AP. RoHS LAN 1 LAN 2 LAN 1 LAN 2

JetWave IEEE802.11a Wireless Outdoor AP/Bridge. Installation. Wireless Outdoor AP. RoHS LAN 1 LAN 2 LAN 1 LAN 2 IEEE802.11a /Bridge RoHS IEEE 802.11a 5GHz band with maximum net data rate of 54 Mbit/s High Gain 23dbi Panel Antenna maximizes transmission distance to at least 40KM Rugged IP67 Protection Housing for

More information

Series Watt DC Power Supplies

Series Watt DC Power Supplies Keithley Instruments 28775 Aurora Road Cleveland, Ohio 44139 1-800-935-5595 http://www.keithley.com Series 2268 850-Watt DC Power Supplies Specifications SPECIFICATION CONDITIONS This document contains

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If

More information

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2

DPST-NO None 2 channels Auto-reset Inverse (+/-) 24 VAC/VDC 4 G9SB-2002-A 1 channel or 2 Safety Relay Unit Ultra Slim Safety Relay Unit 17.5 mm wide models available with 2 or 3 poles. 22.5 mm wide 3 pole models also available EN Standards (TÜV approval) DIN-track mounting possible Ordering

More information

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals)

R6-NC1 BEFORE USE... POINTS OF CAUTION. INSTRUCTION MANUAL CC-Link INTERFACE MODULE MODEL. (CC-Link Ver.1.10; for 16-point analog signals) INSTRUCTION MANUAL CC-Link INTERFACE MODULE (CC-Link Ver..; for -point analog signals) MODEL R-NC BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received

More information

LCOS Projector 4K6020Z

LCOS Projector 4K6020Z LCOS Projector 4K6020Z Basic specifications 1.Product classification Item name Image device, number Projection lens Projector Reflective LCD panel (LCOS), 3 panels Detachable 2.Image device Number of pixels

More information

Mini Photoelectric Sensor

Mini Photoelectric Sensor Mini Photoelectric Sensor High cost-performance Mini Photoelectric Sensor Saves Installation Space and Wiring Effort and Detects Minute Sensing Objects Pin-point beam (1 to 2-mm dia.) makes it possible

More information

SYSMAC Remote Transistor Module

SYSMAC Remote Transistor Module 9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models

More information

RS232C/RS485 Data can be easily monitored by LAN

RS232C/RS485 Data can be easily monitored by LAN KS SIGNAL CVERTER (AKS) RSC/RS8 Data can be easily monitored by LAN KS SIGNAL CVERTER FEATURES The connectors are located on the front panel. Easy to connect Easy to operate Can be connected to the LAN

More information

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4.

CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. POWER SUPPLY RELAY OUTPUTS. Power supply. 4. CLIMATIX STEQ, STCM DATASHEET FOR CONTROLLING, SWITCHING AND MONITORING FUNCTIONS. 4. Relays Power supply 2. Relays 8. Universal Inputs/ Process Bus (KNX) RS485 (Modbus) Tool (USB) Ethernet Tool (USB)/

More information

SCADAPack Smart RTU

SCADAPack Smart RTU SCADAPack 330 334 Smart RTU 1 Built on the proven SCADAPack 300 platform, the SCADAPack 330 and 334 feature high-performance 32-bit processing, highspeed LAN, serial and USB communications, integrated

More information

VER05 Series. xxx Series. 5 Watt. AC-DC Power Supplies. Models & Ratings. Input. Output

VER05 Series. xxx Series. 5 Watt.   AC-DC Power Supplies. Models & Ratings. Input. Output 5 Watt xxx Series Energy Efficiency Level VI Barrel Jack & USB Versions Interchangeable Mains Connectors Included Universal Input Output Voltages from 5.0 V to 12.0 V Class II Construction Low Cost B R

More information

Classification Enclosure rating Input voltage Type of

Classification Enclosure rating Input voltage Type of Slim Relay G2RV The World's First Industrial Slim Relay Large plug-in terminals for reliable connection. LED indicator and mechanical flag to check operation. Special input type with gold plated contacts.

More information

SpectraGuard Sensor SS-300-AT-C-50 Technical Specifications

SpectraGuard Sensor SS-300-AT-C-50 Technical Specifications SpectraGuard Sensor SS-300-AT-C-50 Technical Specifications 1 Product Overview ITEM Product Name Model Number Power Supply SpectraGuard Sensor SS-300-AT-C-50 802.3af Class 0 Power Over Ethernet Nominal

More information

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)

R1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points) INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.

More information

Device Networking Access

Device Networking Access Device Networking Access Industrial Wireless Serial Device Server SW550X Series RoHS compliant Designed for 2.11a/b/g/n networks The SW550X Series is our latest addition to our Industrial Embedded PCB

More information

Industrial IEEE a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features

Industrial IEEE a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features IGAP-620 / IGAP-620+ Industrial IEEE 802.11 a/b/g/n wireless access point with 2x10/100/1000Base-T(X) Features High Speed Air Connectivity: WLAN interface support up to 300Mbps link speed Highly Security

More information

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X

Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Energy Management Modular DC Energy analyzer Type VMU-E and VMU-X Modular solution based on the combination of two units: VMU-E analysis unit and VMU-X universal power supply and RS485 communication unit.

More information

Bulletin 855E 50 mm Control Tower Stack Lights

Bulletin 855E 50 mm Control Tower Stack Lights Bulletin 855E 50 mm Control Tower Stack Lights Light Modules Sound Modules Flashing Incandescent 855E 10 FN 4 Voltage Light Module Type Lens Color 00 0 250V AC/DC (no lamp module) (1) XN Steady no lamp

More information

WLAN Products 2.1 Overview P WLAN Remote Maintenance Device P WLAN Converter P Applications P2-4-1

WLAN Products 2.1 Overview P WLAN Remote Maintenance Device P WLAN Converter P Applications P2-4-1 WLAN Products.1 Overview P-1-1. WLAN Remote Maintenance Device P--1.3 WLAN Converter P-3-1.4 Applications P-4-1 Overview.1. Overview WLAN Products Overview 1 WLAN (Wireless Local Area Network) links devices

More information

Quick Start Guide. Indoor Stand-Alone Access Point. SunSpot AC1200 and SunSpot N300.

Quick Start Guide. Indoor Stand-Alone Access Point. SunSpot AC1200 and SunSpot N300. Indoor Stand-Alone Access Point SunSpot AC00 and SunSpot N300 The SunSpot N300 and the SunSpot AC00 are single- and dual-band concurrent access points (AP s) respectively. The units are designed to be

More information

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only)

Product Discontinuation Notices. Discontinuation Notice of Compact proximity sensor TL-M series (for china area only) PRODUCT NEWS Product Discontinuation Notices August 1, 2011 Proximity Sensors No. 2011248E-2 Discontinuation Notice of Compact proximity sensor (for china area only) Product Discontinuation Recommended

More information

Programmable Relay ZEN V2 Units

Programmable Relay ZEN V2 Units Programmable Relay ZEN V2 Units Please read and understand this catalog before purchasing the products. Please consult your OMRON representative if you have any questions or comments. Refer to Warranty

More information

Drawing No. Page NHL-3FV1N-W18 SPECIFICATIONS. Product Name: Network Monitor Signal Tower with MP3 Model: NHL-3FV1N-RYG

Drawing No. Page NHL-3FV1N-W18 SPECIFICATIONS. Product Name: Network Monitor Signal Tower with MP3 Model: NHL-3FV1N-RYG SPCIFICATIONS Product Name: Network Monitor Signal Tower with MP3 Model: NHL-3FV1N-RYG 1. General Specifications Model NHL-3FV1N Rated Voltage 24VDC (Main Unit) Operating Voltage Range Rated Voltage ±10%

More information

In-Sight 7010C/7200C/7400C

In-Sight 7010C/7200C/7400C The following sections list general specifications for the In-Sight vision system. Vision System Specifications Table 3-1: Vision System Specifications Specifications Minimum Firmware Requirement Job/Program

More information

Multi-Point Gas Detection and Control System

Multi-Point Gas Detection and Control System Multi-Point Gas Detection and Control System Specifications subject to change without notice. USA 40804 Page of 7 DESCRIPTION Wall mounted, microprocessor-based, multi-point, analog electronic control

More information

General Specifications

General Specifications General Specifications YFGW710 Field Wireless Integrated Gateway GENERAL This General Specification (GS) describes the hardware specifications for Field Wireless Integrated Gateway and specifications of

More information

Page. Rev. Drawing No. NHL-5FV2-W18 SPECIFICATIONS. Product Name: Network Monitor Signal Tower with MP3 Model: NH - FV2 -

Page. Rev. Drawing No. NHL-5FV2-W18 SPECIFICATIONS. Product Name: Network Monitor Signal Tower with MP3 Model: NH - FV2 - NHL5FV2W18 SPECIFICATIONS Product Name: Network Monitor Signal Tower with MP3 Model: NH FV2 NHL5FV2W18 1. General Specifications 5 tiers NHL5FV2 NHP5FV2 4 tiers NHL4FV2 NHP4FV2 Model 3 tiers NHL3FV2 NHP3FV2

More information

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges

Solid-state Timer. Ordering Information. Specifications. Miniature Timer Compatible with the MY Relay. Accessories. Time Ranges Solid-state Timer Miniature Timer Compatible with the MY Relay Large transparent time-setting knob facilitates time setting. Flat-blade and Phillips screwdrivers can also be used for time setting. Approved

More information

LVX Control Unit. Features:

LVX Control Unit. Features: Date 2013-02-28 Control Unit Features: Most parameters can be defined as required for your interfaces. You decide which information is output and how. Fast cycle times, just a few µs/beam. Maximum beam-count

More information

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function.

E4PA-N. Application Examples. Features. Ultrasonic Displacement Sensor. Now, more advanced with a new mutual interference prevention function. Ultrasonic Displacement Sensor Now, more advanced with a new mutual interference prevention function. Application Examples Detecting slackness in sheet materials Detecting liquid levels Remotely detecting

More information

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE

73VR3000 PAPERLESS RECORDER MODEL. Paperless Recording System. (selectable input modules) MODEL & SUFFIX CODE SELECTION 73VR3000 R3 TYPE Paperless Recording System PAPERLESS RECORDER (selectable input modules) MODEL & SUFFIX CODE SELECTION MODEL 144 (5.67) MODEL LANGUAGE E : English N : Japanese POWER INPUT M2: 100 240V AC R : 24V DC A

More information

Model Number Structure

Model Number Structure Solid State Relays with Failure Detection Function G3PC Detects failures in SSR used for heater temperature control and simultaneously outputs alarm signal. This SSR supports the safe design of heater

More information