PRODUCT INFORMATION. DeviceNet Triple Play Digital Communications Board. SA Actuator with AUMA Matic Motor Controls
|
|
- Estella Floyd
- 5 years ago
- Views:
Transcription
1 GENERAL DESCRIPTION The DeviceNet Digital Communications Board is furnished in the AUMA Matic motor control housing for controlling electric motor driven actuators used on valves, dampers and other devices. The board serves as the actuator s interface with the plant control system. SA Actuator with AUMA Matic Motor Controls DeviceNet Digital Communications Board Page 1 of 5
2 Detailed Description The primary actuator communication protocol is the open, non-proprietary DeviceNet protocol. DeviceNet is a modern communication system that is easy to install and configure. Through the use of EDS (electronic data sheets) files, system configuration is very quick and easy. The EDS file defines the communication requirements and I/O properties of the actuator. During system configuration, each node (actuator) on the network is automatically matched to the appropriate EDS file by a DeviceNet configurator. This allows the I/O information from each actuator to be mapped into the DeviceNet scanner without operator knowledge of the equipment. This process greatly simplifies system configuration allowing an entire network to be configured in minutes. DeviceNet is also supported by most major equipment manufacturers. That means off-the-shelf solutions are available for many control problems. Flexibility has been built-in. This board has been called the "Triple Play" because older technology has been built-in allowing control using either the Modbus Protocol or an Analog Positioning Signal. This is a very attractive option for customers who want to migrate to a new High-Technology Protocol from either the Modbus or Analog control. The plant can continue to operate using existing control technology and move to the advanced protocol with no additional actuator hardware. The board has 8 digital inputs, 4 digital outputs, and 5 analog inputs. These I/O are completely definable by the customer. Customer Configuration: The 7 digital inputs are typically used to monitor actuator indications: Open Limit Switch Open Torque Switch Close Limit Switch Close Torque Switch Thermal Contact Incorrect Voltage Phasing Selector Switch in Remote Two of the four digital outputs are usually: Open Command Close Command One of the analog inputs is Actuator Position. This typically leaves 1 digital input, 2 digital outputs and 4 analog inputs remaining for special customer requirements. Page 2 of 5
3 DeviceNet / Technical Details Communication protocol Network topology CAN Controller Area Network Two shielded twisted pair in one cable (power and signal on same network cable) per DeviceNet specifications DeviceNet Linear (trunkline/dropline) bus, bus termination on both ends Removal of stations without affecting other stations Transmission Speed and Line Length Note: Kbaud = 1000 bits/s Number of Stations Bus access data transfer rate 125 Kbaud 250 Kbaud 500 Kbaud 64 stations per scanner Master-Slave line length 500 meters / 1640 ft. 250 meters / 820 ft. 100 meters / 328 ft. Note: CAN extenders allow much longer lengths (eg.: 10 extenders at 125 Kbaud becomes 5,500 meters / 3.4 miles in length) Error Management Indications Fault Indications Analog / digital inputs Digital outputs DeviceNet Port Power Consumption Proven CAN Standard including CRC (Cyclic Redundancy Check) on each frame; Excellent diagnostic capabilities and network status OPEN STOP CLOSE Run to Setpoint Position End-of-travel positions OPEN, CLOSED Continuous valve position Selector switch in position LOCAL / OFF / REMOTE Open torque switch tripped Closed torque switch tripped Motor protection tripped Phase failure, wrong phase sequence Open torque switch tripped in mid-travel (available) Closed torque switch tripped in mid-travel (available) 5 analog inputs 8 digital inputs 4 digital outputs 75 ma (max.) at 24 VDC Page 3 of 5
4 MODBUS / Technical Details Communication protocol Network topology EIA-485 (RS-485) Shielded twisted pair MODBUS (ASCII or RTU) Linear bus (line) Data transfer rate data transfer rate in bit/s distance / segment length in m Number of stations No. active stations (masters) 1 Bus access 2,400 9,600 19,200 1, stations in each segment without repeaters, up to 247 stations with repeaters (6) Master-slave Function Codes 01 Read Coil Status 02 Read Input Status (Coils) (Registers) Indications 02 (Input Status) 04 (Registers) Fault Indications 02 (Input Status) Analog / digital inputs Digital outputs 03 Read Holding Registers 04 Read Input Registers 05 Single Coil Write 06 Single Register Write 15 Multiple Coil Write 16 Multiple Register Write OPEN - Coil STOP - Coil CLOSE - Coil Run to Setpoint Position - Register End-of-travel positions OPEN, CLOSED - Status Selector switch in position LOCAL / OFF / REMOTE - Status Open torque switch tripped - Status Closed torque switch tripped - Status Continuous valve position - Register Motor protection tripped - Status Phase failure, wrong phase sequence - Status Open torque switch tripped in mid-travel (option) - Status Closed torque switch tripped in mid-travel (option) - Status 5 analog inputs / 8 digital inputs 4 digital outputs Page 4 of 5
5 Analog interface / Technical Details Signal Type Communication function Monitoring capabilities (No control) Status Relay failure Analog control Shielded twisted pair Voltage signal (Range: 0-10VDC) Current signal (Range: 0 20 ma) Actuator positioned according to control signal value Actuator will fail as is or fail to a preset position when control signal is below the minimum defined value for the actuator. DeviceNet or Modbus Loss of signal Loss of board power All information is subject to change without notice. 4 Zesta Drive Pittsburgh, PA USA Ph: Page 5 of 5
PRODUCT INFORMATION. AUMA Actuators, Inc. Pittsburgh PA USA. Triple Play Digital Communications Board DeviceNet / Modbus CDN455
GENERAL DESCRIPTION The CDN455 Digital Communications Board is furnished in the AUMA Matic motor control housing for controlling electric motor driven actuators used on valves, dampers and other devices.
More informationModbus. Serial communication and control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems
Electric Actuators and Control Systems Established Leaders in Valve Actuation Modbus Serial communication and control of Rotork actuators Publication S117E Issue 04/09 Rotork actuators have been in use
More informationIssue Abbreviated BSP-Numbering system AUMA MATIC BASIC types AMB and Basic Compact (AUMA Actuators Inc.) Uncontrolled copy!
Issue 2004-06-16 Abbreviated BSP-Numbering system AUMA MATIC BASIC types AMB and Basic Compact (AUMA Actuators Inc.) Only for internal use EWH-34 SHORT GB-01 Distributor: Uncontrolled copy! Issue 1 dated
More informationModbus Actuator Control
Modbus Actuator Control Serial communication and control of Rotork actuators Redefining Flow Control Contents Section Page Introduction 3 Modbus Overview 4 Modbus Features Modbus Module 5 RS-485 Communication
More information01325T -- Robot Welder
WELDING MANIFOLDS WITH DeviceNet INTERFACE 01325T -- Robot Welder 01326T -- Pedestal Welder Station #2 (WELD) SOL 14 Station #1 (BACKUP) SOL 14 SOL 12 Prop. Reg. Water Saver Inputs Power (Aux.) DeviceNet
More informationDual Module VCT. 5. Lexan Enclosure is Water & Corrosion Proof Contaminants will not affect the module as long as terminal strip is not immersed.
2 The integrates position sensing, communication electronics, power outputs, auxiliary inputs and wire termination into a fully sealed compact package. The module also integrates a terminal strip directly
More informationWe reserve the right to alter data according to improvements made. Previous documents become invalid with the issue of this document.
General information AC 01.2 actuator controls for controlling multi-turn actuators of the SA/SAR.2 type range and part-turn actuators of the SQ/SQR type range with interface. Features and functions Power
More informationepac Operation & Instruction Manual For Non-intrusive feature 1 P a g e
epac Operation & Instruction Manual For Non-intrusive feature 1 P a g e INDEX: I INDEX 1 II INTRODUCTION 2 III FRONT PANEL DETAILS 2 IV PROGRAM MODE 5 CALIBRATION MODE 10 V VI TOPOLOGY & TERMINATION DETAILS
More informationMULTIPLE PROTOCOLS FOR VALVE ACTUATOR CONNECTIVITY
MULTILE ROTOCOLS FOR VALVE ACTUATOR CONNECTIVITY EIM CONTROLS WHICH ROTOCOL IS BEST FOR YOUR ALICATION? This document provides a brief description of each protocol, along with EIM s implementation of that
More informationOutline. EtherNet/IP Introduction EtherNet/IP products EtherNet/IP Ring Topology Implicit and Explicit Message Applications
EtherNet/IP Outline EtherNet/IP Introduction EtherNet/IP products EtherNet/IP Ring Topology Implicit and Explicit Message Applications Outline EtherNet/IP Introduction EtherNet/IP products EtherNet/IP
More informationStandard Options. Model 4100 Position Indicating Meter. Three Phase Motor Control. Positran Transmitter
Standard Options Model 4100 Position Indicating Meter A percent-of-full-travel meter is supplied with a trim potentiometer resistor, terminal block and connectors. A potentiometer is required in the actuator
More informationInstallation and maintenance instructions
Before installation these instructions must be fully read and understood Table of contents 1. Introduction... 1 2. Operation and storage... 1 3. Distinguish OLD/NEW models... 1 4. Installation... 3 4.1
More informationBus Transmitter Expansion Module (Fiber Media) with built-in switch. PROFINET Slave, Version 2.2 Class A IO-Device
Remote I/O Units A Remote I/O Unit connects modules to a host PLC or computer via a variety of networks. This makes it easy to include in the innovative PROFINET interface, as well as Genius, Profibus-DP,
More informationELECTRIC ACTUATORS Innovations for SGC part-turn actuators and SVC valve actuators
ELECTRIC ACTUATORS Innovations for SGC part-turn actuators and SVC valve actuators SGC PART-TURN ACTUATORS 2 SVC GLOBE VALVE ACTUATORS 3 NEWS ON COMPACT ACTUATORS 3 SVC globe valve actuators with enhanced
More informationHART INTERFACE FOR INTELLI+
User Manual HART INTERFACE FOR INTELLI+ 4 rue d'arsonval - BP 70091 95505 GONESSE cedex Tel: +33 (0) 1 34.07.71.00 Fax: +33 (0) 1 34.07.71.01 1 www.bernardcontrols.com Modification Control Indice Date
More informationL5353 Profibus-DP Communications Interface
L5353 Profibus-DP Communications Interface Technical Manual HA470380 Issue 2 Copyright SSD Drives, Inc 2005 All rights strictly reserved. No part of this document may be stored in a retrieval system, or
More informationACExC 01.2 Modbus TCP/IP
General information ACExC 01.2 actuator controls for controlling multi-turn actuators of the SAEx/SAREx.2 type range and part-turn actuators of the SQEx/SQREx.2 type range with interface. Features and
More informationisma-b-fcu FCU Hardware User Manual Global Control 5 Sp. z o.o. Warsaw, Poland
isma-b-fcu User Manual FCU Hardware Global Control 5 Sp. z o.o. Warsaw, Poland www.gc5.pl Table of contents 1 Introduction 3 1.1 Document change log 3 1.2 Safety rules 3 1.3 Technical specifications 4
More information01348(N or G) MH** -- Material Handling (N or G) MH** -- Material Handling
MATERIAL HANDLING MANIFOLDS WITH DeviceNet INTERFACE 01348(N or G) MH** -- Material Handling 01351(N or G) MH** -- Material Handling Note: N = NPT ports G = BSPP ports SOL 14 SOL 12 Station #3 SOL 14 SOL
More informationINTELLIS. WESTLOCK Network Systems Group NETWORK SYSTEMS FOR VALVE AUTOMATION. ModBus, DeviceNet, AS-interface Profibus, Foundation Fieldbus
INTELLIS NETWORK SYSTEMS FOR VALVE AUTOMATION ModBus, DeviceNet, AS-interface Profibus, Foundation Fieldbus WESTLOCK Network Systems Group INTELLIS Network Systems for Valve Automation I ntellis is a family
More informationINSTRUCTION SHEET. Eaton Logic Controller DeviceNet Distributed I/O Adapter Module. [Applicable Distributed I/O Adapter Module] ELC-CADNET
2010-12-10 5011697801-ECD1 Eaton Logic Controller DeviceNet Distributed I/O Adapter INSTRUCTION SHEET [Applicable Distributed I/O Adapter ] IL05004007E 002-1214120-02 Thank you for choosing the Eaton Logic
More informationQUCM Limitorque Controller
QUCM Limitorque Valve Controller Application Manual QUCM Limitorque Controller Installation and Programming Manual This Manual describes the QUCM application for interfacing Limitorque Valve Actuators
More informationSPM90 MODBUS PROTOCOL AND REGISTER LIST V1.0
SPM90 MODBUS PROTOCOL AND REGISTER LIST V1.0 目 录 1. Introduction... 1 1.1 Purpose of the Communication Protocol... 1 1.2 Version of Communication Protocol... 1 2. Detailed Description of the SPM90 Modbus
More informationM-series Profibus DP Series 2 Plus Interface Card
DeltaV Distributed Control Systems Product Data Sheet M-series Profibus DP Series 2 Plus Interface Card The DeltaV M-series Profibus DP Interface Card provides the solution for interfacing to discrete
More informationDiagnostics (Logical) Diagnostics (Physical)
Enclosure Mounted Input/Output Stations In-Cabinet I/O IP 20 Protection Ideal for Retrofits Automatic Baud Rate Sensing FDN20-4S-4XSG FDN20-4S-4XSG-E* FDN20-4S-4XSG-DIN* * Not UL Electrical Operating Current:
More informationPROFIBUS Additional Board for SMARTCON Control System
SEC- 1 General Information A fieldbus interface is available for SCHIEBEL actuators in the ACTUSMART and SMARTCON series for the standardised bus system PROFIBUS-DP. This interface is a hardware option
More informationELECTRIC ACTUATORS Compact devices for the automation of globe valves, ball valves and butterfl y valves
ELECTRIC ACTUATORS Compact devices for the automation of globe valves, ball valves and butterfl y valves SGC PART-TURN ACTUATORS 2 SVC GLOBE VALVE ACTUATORS 3 SGC part-turn actuators and SVC globe valve
More informationUSER INSTRUCTIONS. Limitorque Master Station III. Installation Operation Maintenance. Experience In Motion FCD LMENIM /13
USER INSTRUCTIONS Limitorque Master Station III FCD LMENIM5001-02 12/13 Installation Operation Maintenance Experience In Motion Contents 1. Introduction 5 2. Function Flowchart 9 3. Quick Startup 12 4.
More informationSDM-8AO. Expansion Module 8 analog outputs. Manufactured for
Version 1.0 16.05.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationMPCR Series DeviceNet Technical Manual TDMPCRDNTM2-0EN 01/08 Subject to change without notice
MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction... 3 Product Overview... 3 About DeviceNet... 4 Overview... 4 MPCR DeviceNet Features... 4 Cabling and Drop Line Lengths
More informationPowered to Perform. Everyday Reliability. Exceptional Value. Expertise and Support
A decentralized solution. Many drive applications utilize control panels with complex wiring taking up large amounts of space. These control panels are often mounted away from the application requiring
More informationUSER MANUAL. Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26
USER MANUAL Modbus IHP24-A IHP24-AF IHP24-B IHP24-BF IHP24-F IHP24-I 1/26 Table of contents 1 General... 3 1.1 Safety instructions... 3 2 Purpose... 4 3 Specifications... 5 3.1 Electrical specifications
More informationTURCK Industrial I/O DeviceNet Products
TURCK Industrial I/O DeviceNet Products F1 TURCK Inc. 3000 Campus Drive Minneapolis, MN 55441 Application Support: 1-800-544-7769 Fax: (763) 553-0708 www.turck.com Industrial Automation DeviceNet System
More informationCarbon Monoxide Sensor - ModBus
Introduction The CO Sensor uses an electrochemical sensor to monitor CO level in a range of 0 to 500 ppm and communicates via an RS-485 network configured for ModBus protocol. Before Installation Read
More informationStep 1: Choose the Appropriate CPU Step 2: Make the Connections
CHAPTER GS1 MODBUS 5 COMMUNICATIONS Contents of this Chapter... Communication Parameters Summary.....................5 2 GS1 Parameter Memory Addresses........................5 4 GS1 Status Addresses..................................5
More informationLowering Lifecycle Costs
Lowering Lifecycle Costs with Intelligent Motor Control Centers Standards Certification Education & Training Publishing Conferences & Exhibits Speakers: Presented and Authored by Jeff M. Miller, PE, ENV
More informationINSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC.
INSTRUCTION MANUAL STATION CONTROLLER SC1000 MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road, Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Revision Date: 9-11-08 Applications: Simplex,
More informationAL2-MBU Advanced Manual
AL2-MBU Advanced Manual REVISION 003.08 December 2008 REVISION LIST 001.08 January 2008 Preliminary version 002.08 June 2008 First official release 003.08 December 2008 New feature: Force Multiple Coils
More informationOptidrive Applications Support Library
Optidrive Applications Support Library Application Note Title AN-ODE-3-038 Related Products Optidrive E3 Overview Level 3 Modbus RTU Control and Register Mapping 1 Fundamental - No previous experience
More informationDesign of Communication Function Test System for Intelligent Low Voltage Electrical Apparatus Based on LabVIEW and Modbus RTU Protocol
2017 Asia-Pacific Engineering and Technology Conference (APETC 2017) ISBN: 978-1-60595-443-1 Design of Communication Function Test System for Intelligent Low Voltage Electrical Apparatus Based on LabVIEW
More informationADJUSTABLE SPEED DRIVES. QX7 Series. HVAC 18-Pulse. Phone: Fax: Web:
ADJUSTABLE SPEED DRIVES QX7 Series HVAC 18-Pulse Toshiba QX7 The Toshiba QX7 adjustable speed drive is designed for HVAC applications where harmonic content is critical to the power grid. The QX7 s patented
More informationFieldLink process networking
FieldLink process networking Enclosures Junction module (JM) StoneL s Junction Module (JM) enclosure is an environmetally hardened platform which is suitable for use in the most extreme corrosive and hazardous
More informationIFC 100 Supplementary instructions
IFC 100 Supplementary instructions Signal converter for electromagnetic flowmeters Description of Modbus interface Electronic Revision: ER 3.0.xx Modbus version: 1.0.xx KROHNE CONTENTS IFC 100 1 Important
More informationAS-Interface INSTALLATION GUIDE, TIPS AND TRICKS
AS-Interface INSTALLATION GUIDE, TIPS AND TRICKS AS-Interface Installation guide Tips and Tricks 2 Index AS-Interface General Features 4 AS-Interface Key Features 7 Selecting the Cable 8 Cable Routing
More informationMPCR Series DeviceNet Technical Manual
MPCR Series DeviceNet Technical Manual Table of Contents MPCR Series Introduction...3 Product Overview...3 About DeviceNet...4 Overview...4 MPCR DeviceNet Features...4 Cabling and Drop Line Lengths (as
More informationM-series Profibus DP Series 2 Plus Interface Card
January 2013 Page 1 M-series Profibus DP Series 2 Plus Interface Card The DeltaV M-series Profibus DP Interface Card provides the solution for interfacing to discrete actuators and sensors. Offers freedom
More informationUser Guide IM/C250 MOD_3. Modbus (RTU) Communications Option C250 and V250
User Guide IM/C250 MOD_3 Modbus (RTU) Communications Option C250 and V250 Electrical Safety This instrument complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements for electrical
More informationABOUT THE DEVICENET SMARTMOTOR
ABOUT THE DEVICENET SMARTMOTOR DeviceNet Overview DeviceNet is an open network standard that provides for reduced system complexity and significant reductions in wiring costs. DeviceNet allows a SmartMotor
More informationInstruction Manual. Save These Instructions. Centrifugal Compressor Control System. Model Xe-145F Modbus. Instruction Manual
80446685 Revision B April 2013 Centrifugal Compressor Control System Model Xe-145F Modbus Instruction Manual Instruction Manual Save These Instructions Contents OVERVIEW...................................................................................................
More informationAnybus-CC CFW-11. User s Manual. Phone: Fax: Web: -
Anybus-CC CFW-11 User s Manual Anybus-CC User s Manual Series: CFW-11 Language: English Document Number: 0899.5750 / 06 Publication Date: 09/2013 CONTENTS CONTENTS... 3 ABOUT THE MANUAL... 6 ABBREVIATIONS
More informationTechnical Manual. HA Issue 4. Copyright Parker SSD Drives, Inc 2008
Technical Manual HA470380 Issue 4 Copyright Parker SSD Drives, Inc 2008 All rights strictly reserved. No part of this document may be stored in a retrieval system, or transmitted in any form or by any
More informationGE Power Management. MMII Intelligent MCC Controller
A concept that will offer reduced overall installed cost and production efficiency through information availability to operators and maintenance. Presentation Overview 6 Applications 6 Protection and Control
More informationMeasure & Control Temperature & CO2 levels with analog & digital I/O
MADE IN OZ HTC-DIGITAL-LCD PROGRAMMABLE TEMPERATURE CONTROLLER c/w YEARLY PROGRAMMABLE TIME SWITCH COMPATIBLE WITH A WIDE RANGE OF SENSORS ROOM O/A WALL DUCT PIPE Use Features Measure & Control Temperature
More informationMotors I Automation I Energy I Transmission & Distribution I Coatings. SymbiNet CFW-11. User s Manual
Motors I Automation I Energy I Transmission & Distribution I Coatings SymbiNet CFW-11 User s Manual SymbiNet User s Manual Series: CFW-11 Language: English Document Number: 10002033446 / 00 Publication
More informationSMART E-BILL GENERATION USING PLC
RESEARCH ARTICLE SMART E-BILL GENERATION USING PLC A.PRIYANKA 1, G.SAHITHI 2, SNEHA 3, K.RAMANJANEYA REDDY 4 1(Assistant Professor, Electronics and communication engineering, AITS, Rajampet Email : priyanka3aluru@gmail.com)
More informationUSER INSTRUCTIONS. Limitorque Master Station III. Installation Operation Maintenance. Experience In Motion FCD LMENIM /12
USER INSTRUCTIONS Limitorque Master Station III FCD LMENIM5001-01 05/12 Installation Operation Maintenance Experience In Motion Contents 1. Introduction 5 2. Function Flowchart 9 3. Quick Startup 12 4.
More informationETHERNET/MFC 010 Technical Datasheet
ETHERNET/MFC 010 Technical Datasheet EtherNet/IP interface box in combination with MFC 010 Seamless integration into EtherNet/IP environments Integrated web server for easy configuration, maintenance and
More informationIntellis Network Control Monitors
Non-hazardous, Intrinsically Safe, Explosionproof/Flameproof - ATEX/IEC Intellis is a family of fully-integrated control monitors that provide cost-effective valve automation and intelligent networking
More informationTHE FULL RANGE FOR PROCESS AUTOMATION. This document provided by Barr-Thorp Electric Co., Inc
THE FULL RANGE FOR PROCESS AUTOMATION www.turck.com TURCK Process Automation Networks DeviceNet Selection Guide AIM Page FDN20 Page OEM Page Discrete Input J11-J13, J29, J37 Discrete Input & Ouput J59
More informationWireless Transducer MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:
Wireless Transducer INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 2 Revision
More informationVersaMax IP. Proficy Machine Edition. Publication Reference Chart
Distributed I/O is designed to offer the ruggedness and reliability of a standard I/O system installed in a NEMA 4 cabinet, without the cost and effort to build the cabinet. is IP67 rated so it can be
More informationLMV2 / LMV3... Modbus. User Documentation. Building Technologies Division
LMV2 / LMV3... Modbus User Documentation The LMV2... / LMV3... burner management system and this User Documentation are intended for OEMs and system integrators which integrate the system in their products!
More informationSDM-6RO. Expansion Module 6 relay outputs. Manufactured for
Version 1.0 5.02.2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationRS485 MODBUS Module 8AO
Version 1.3 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationDiagnostics (Physical)
DeviceNet Spanner Rugged, Fully Potted Stations IP 67 Protection Communicate Between s Connect Two DeviceNet Networks FDN-DN1 Electrical Operating Current: 125 ma from segment A, 30 ma from segment B Power
More informationM-System s. 17 years of successful sales, 480,000 total units sold! selectable. Mixed Signal. Mixed Signal. Compact, Mixed Signal
M-System s 0-0 EC-Z -00 Rev. 000 years of successful sales, 0,000 total units sold! Freely communicates with host devices without needing extra programming. Compliant with major open networks regularly
More informationDeviceNet. Controller Area Network control of Rotork actuators. Established Leaders in Valve Actuation. Electric Actuators and Control Systems
Electric Actuators and Control Systems Established Leaders in Valve Actuation DeviceNet Controller Area Network control of Rotork actuators PUB060-004-00 Issue 05/10 Rotork actuators have been in use all
More informationRS485 MODBUS Module 6RO
Version 2.0 12/02/2013 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained in this manual have
More informationHow to Control and Monitor a C441 Motor Insight via DeviceNet
Application of DeviceNet and Motor Insight How to Control and Monitor a C441 Motor Insight via DeviceNet Application: The purpose of this application example is to demonstrate how to control and monitor
More informationMODERNIZE YOUR DC CRANES. Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives
TM MODERNIZE YOUR DC CRANES Convert Your DC Controls to State-of-the-Art Energy Efficient OmniPulse DDC Series 2 Drives Magnetek, the leader in digital power and motion control systems, brings you the
More informationSAE J1939. Serial Control and Communications Vehicle Network
SAE J1939 Serial Control and Communications Vehicle Network Literature Literature on Controller Area Network, CANopen and SAE J1939 Page 2 What is SAE J1939 General Aspects Higher-layer protocol based
More informationXPSMF35. Product data sheet Characteristics. Preventa safety PLC compact - Profibus DP protocol. Main. Complementary. Safety module name
Product data sheet Characteristics XPSMF3542 Preventa safety PLC compact - Profibus DP protocol Main Range of product Product or component type Safety module name Safety module application Nov 13, 2018
More informationSC1000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703
SC1000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Operating Program Revision: 8 Revision Date: 5-16-11 STATION
More informationAC 01.2 Foundation Fieldbus
General information AC 01.2 actuator controls for controlling multi-turn actuators of the SA/SAR.2 type range and part-turn actuators of the SG/SGR type range with interface. Features and functions Power
More information3 CH Analog Output module / CANopen
3 CH Analog Output module / CANopen Power Supply 1..4 Vdc, 19..28 Vac Isolation 1,5 kvac (5 way) Accuracy,5% A/D resolution 14 bit Channels 3 Voltage range 1 V Current range..2, 4..2 ma RPDO < 2 ms (-1%
More informationINTELLIS. Modbus Direct Network Monitor
INTELLIS Modbus Direct Network Monitor System Installation and Operation Manual Phone: (201) 794-7650 Fax: (201)794-0913 Chapter 1 Modbus Protocol Revision History Revision 1.0 30 April, 2002 Initial Version
More informationE.CK Centronik Control and Indication Specification CENTRONIK FUNCTION AND PROTECTION DETAILS. Local Control. Local Indication.
TITLE: MODELS: CENTRONIK FUNCTION AND PROTECTION DETAILS CENTRONIK UNIT Centork CKC and CKRC range actuators with Centronik controls have an assigned wiring diagram and terminal plan for the specific build
More informationRS 485 Mini Modbus 1AO
RS 485 Mini Modbus 1AO Version 1.0 14/08/2014 Manufactured for Thank you for choosing our product. This manual will help you with proper support and proper operation of the device. The information contained
More informationNon-communicating room controllers
3 881 DESIO RXA on-communicating room controllers For fan-coil systems RXA20.1 RXA21.1 RXA22.1 The RXA20.1, RXA21.1 and RXA22.1 room controllers are used for temperature control in individual rooms. For
More informationQuantum III. Compact DC Drive Package. Slitter DC Drive Package. Quantum III
Compact DC Drive Package The delivers a DC drive package that integrates the intelligence of the Mentor II with a space saving design that incorporates many accessories typically required in the North
More informationLecture: Communication in PLC
PROGRAMMABLE CONTROLLERS Jerzy Kasprzyk Lecture: Communication in PLC 1. Introduction CPU PADT (Programming And Debugging Tool), RS232 (RS 485) protocols (SNP, Modbus, etc.), Ethernet; LAN (Local Area
More informationUser Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6. /8 DIN Process Indicators and Controllers C100, C150, C160 and V100
User Guide Supplement Modbus TM Serial Data Communications Option IM/C100 MOD_6 1 /8 DIN Process Indicators and Controllers C100, C150, C160 and V100 Electrical Safety This equipment complies with the
More informationOperating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2. Level Indicator L150 and L160
Operating Guide MODBUS (RTU) Communications Option IM/L150 MOD_2 Level Indicator L150 and L160 Electrical Safety This equipment complies with the requirements of CEI/IEC 61010-1:2001-2 "Safety requirements
More informationDeviceNet Expansion Board
DeviceNet Expansion Board Catalog No. EXBD05 Installation and Operating Manual 10/02 Table of Contents Section 1 General Information................................................... 1 1 Introduction.......................................................
More informationSR489 SR489. Generator Management Relay. Economical protection, metering, and monitoring functions for small and medium sized generators.
SR489 Generator Management Relay Economical protection, metering, and monitoring functions for small and medium sized generators. 1 Product Highlights Inputs / Outputs Generator Protection Power Metering
More informationAutomate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control
Welcome to NovaTech Automate and Preserve Electromechanical Relay Investment Part 3 of 3 Using the Bitronics 70 Series to Improve Remote Monitoring and Control Paul Grabowski About the Author Paul Grabowski
More informationFREQUENCY CONVERTER FC102 (QUICK GUIDE)
FREQUENCY CONVERTER FC102 (QUICK GUIDE) INSTALLATION AND MAINTENANCE Content Page Safety instructions 2 IT system 3x230VAC 2 Connections 3 Control unit (LCP) 4 Manual operation 4 Reverse the direction
More informationInterface Definition RISH EM 2340/1320/30/ _Rev. D - 8/2016
Interface Definition RISH EM 2340/1320/30/40 1 2-60-006-00-00494_Rev. D - 8/2016 2 Section DIGITAL MULTIFUNCTION INSTRUMENT Contents 1. Introduction Programmable Multi-function Energy Meter Installation
More informationApplication Note (Revision NEW, 9/2004) Original Instructions Simple Generator Drive Steam Turbine Applications
Application Note 51235 (Revision NEW, 9/2004) Original Instructions Simple Generator Drive Steam Turbine Applications Woodward reserves the right to update any portion of this publication at any time.
More informationExtension Board for MODBUS-RTU on SMARTCON Control Unit
Extension Board for MODBUS on SMARTCON Control Unit SEC-DS-GERMAN-MODBUS-RTU-V2.00-2015.02.12 Extension Board for MODBUS-RTU on SMARTCON Control Unit 1 General Information For SCHIEBEL ACTUSMART or SMARTCON
More informationF02 SERIES ELECTRIC ACTUATORS
F02 SERIES ELECTRIC ACTUATORS F02 Series Overview A WORLD OF EXPERIENCE Biffi has been a leading manufacturer of valve actuators for more than 50 years. As one of the few manufacturers with a global presence,
More informationLUFP9 Telemecanique User s Manual. Gateway DeviceNet / Modbus RTU
LUFP9 Telemecanique User s Manual Gateway DeviceNet / Modbus RTU 1 2 Table of Contents Safety Information...4 Disclaimer...4 About the Book...5 1. Introduction...6 1.1. Introduction to the User s Manual...
More informationDREHMO i - matic Electrical actuator with integral controls
DREHMO i - matic Electrical actuator with integral controls Complementary operating manual for drives with PROFIBUS interface Installation manual T.-Nr. 166781 Operating manual Version 1.14 Date: September,
More informationWhite paper. Communication with SACE Emax 2 circuit-breakers
White paper Communication with SACE Emax 2 circuit-breakers Communication with SACE Emax 2 circuit-breakers Index 1 Introduction...2 2 Communication with SACE Emax 2 circuit-breakers...3 2.1 The trip
More informationMasibus Automation And Instrumentation Pvt. Ltd.
Operator s Manual DIGITAL CONTROLLER 5006H Masibus Automation And Instrumentation Pvt. Ltd. B/30, GIDC Electronics Estate, Sector-25, Gandhinagar-382044, Gujarat, India Ph: 91 79 23287275-79 Fax: 91 79
More informationSelect Family: MicroLogix 1100 or 1400 Controller
Select Family: MicroLogix 1100 or 1400 Controller 21 Select Family: MicroLogix 1100 or 1400 Controller Step 1 - Select: controller family - based on memory, I/O, added functionality, programming instructions
More informationModbus RTU Actuator Control Mk2 Option Card Technical Manual (IQ Pro, IQT Pro, SI Pro, EH Pro, ROMpak and Q)
Modbus RTU Actuator Control Mk2 Option Card Technical Manual (IQ Pro, IQT Pro, SI Pro, EH Pro, ROMpak and Q) Publication PUB091-003-00_1014 Modbus MFU Option Card Installation Manual The Modbus card described
More informationlnvertek Drives.com ct,ve ELECTRICAL SUPPLIERS LTD
lnvertek Drives.com ft ct,ve ELECTRICAL SUPPLIERS LTD OptidriveE2 Technical Product Guide 1.1 OVERVIEW Range IP20 IP66X (NON SWITCHED) IP66Y (SWITCHED) Supply Voltage Range Power Range 110 115 + / 10%
More informationHART. Actuator Control. Redefining Flow Control
HART Actuator Control Contents Section Page Introduction 3 Actuator Control 4 HART Module 5 HART Network 5 Point-To-Point Network 6 Multi-Drop Network 6 Commands 7 Control Features 8-9 Device Description
More informationAUMA 50 YEARS OF ELECTIC ACTUATON
AUMA 50 YEARS OF ELECTIC ACTUATON Motor controls and remote communication Werner Laengin, AUMA Germany ONCE UPON A TIME. 2 THE HISTORY OF COMMUNICATION All these communication protocols are now standardised
More information