1 EDfuse NG - The modern measurement system in high-volt, high-current, low-current and low-volt ranges V

2 EDfuse The modular system for intelligent measurement of operating and quiescent currents in the vehicle The best performance, comfort and safety are features which are required of all vehicles nowadays. In order for these demands to be fulfilled, the complexity of the vehicle continually increases and the number of control devices and electrical consumers also increases permanently. Electrically driven automobiles also promise a way to sufficient, efficient mobility. However, electrical energy in vehicles is a scarce commodity due to the limited storage capacity. This particularly applies to purely electrically driven vehicles as the range rapidly reduces is the use of electrical energy is not optimized. The consumption of fuel is also negatively affected in the case of vehicles with a conventional combustion engine, if the electrical energy is not distributed and used as well as possible. This is why optimization of the energy flow is extremely important. With EDfuse, a modular measurement system developed by EDAG, energy efficiency in the vehicle can be significantly increased. Currents and voltages are precisely detected and documents in order to determine the optimal distribution of electrical energy. Due to the integrated galvanic separation between measurement technology and the vehicle, as well as all measurement elements among themselves, measurements in on-board networks with different supply voltages are possible; low-volt, high-volt or combined lowhigh volt systems. It is not important whether short or long-term measurements are to be carried out. The existing fuse elements can simply be replaced with intelligent measurement sensors and the fuse function is maintained. EDfuse stands for comfortable and efficient validation of electrical energy distribution in the vehicle.

3 EDfuse The Product In contrast to standard measurement methods such as current probe measurement or digital multimeters, the EDfuse works self-sufficiently. After one-off installation, EDfuse can carry out the measurement independently and save the detected data. The data can be analyzed at a later date. EDfuse can be individually arranged according to your requirements and your interests. Due to the modular design of EDfuse, almost all challenges with respect to the distribution of energy in the vehicle can be mastered without any difficulties. EDfuse can be extended with further modules thanks to the modular construction. Whether in stationary or mobile use, the system can also do justice to complex demands. Due to the simple expansion of modules, EDfuse is suitable for use in the workshop as well as for performing highly complex measurements in vehicle development. You will receive an overview of the available components of the EDfuse measurement system on the following page. EDfuse offers solutions for a number of applications: Measurement of currents and voltages in high-volt and high-current systems of hybrid and electric vehicles. Identification of quiescent 1) and operating current problems. Validation and optimization of electrical energy distribution in vehicles. Long-term data storage of all measured currents and voltages. 1) Quiscent current = Ignition Off Draw (IOD)

4 EDfuse system overview It is an advantage of the EDfuse measuring system that it can be variably combined. You can select from the available components the ones which are required for your use and also expand your EDfuse measuring system in future at any time. The modules of EDfuse shown in the figure are illustrated on the following pages in detail. 2x Mini fuse PC ATO fuse Configurator Connecting cable Maxi fuse USB 8x Shunt CAN 12V CAN Interface 1 Connecting cable Clamp-on ammeter Current sensor High-volt CAN Interface 2-n Voltage sensor HV Terminating resistor Voltage sensor Battery case Breakoutcable Temperature sensor Service Case Fuse + Breakoutbox adapters

5 EDfuse Hand Device For mobile use in workshops: The hand device fulfils a central function among the EDfuse modules. Currents and voltages can be immediately measured and recorded due to the possibility of directly connecting two measurement sensors. Due to the simply menu guide, the hand device is quickly and simply ready-for-use, it saves large amounts of data and works self-sufficiently after the initial installation. Analysis of the data found on a SD memory card can therefore take place at a later date. For you, as the user, this guarantees high flexibility and less time. The hand device is designed for demanding temperature ranges and, thanks to the construction, can also be used under difficult external conditions. The integrated battery pack allows a long measurement period of up to eight hours. For complex applications: The device offers more advantages in automobile development, but also in difficult error patterns in the service area. In combination with one or several CAN interfaces or high-volt or high-current sensors, it can detect up to 200 measurement points parallel. The user quickly gains a full overview of the energy distribution in the vehicle. The device works like an CAN data logger. The hand device can also be conveniently used as a display, operating and storage device. Hand device technical specification: Temperature range between -20 C and +60 C (-4 F and 140 F) SD card for data storage up to 32 GB Protection class IP54 Robust construction suitable for the workshop Simple, self-explanatory operation Weight: ca. 1.5 kg (3.3 lbs) Integrated charger Connection options for EDfuse CAN interface Connection options for EDfuse high-current and high voltage sensors Measurement period up to 8h with integrated battery pack for 2 sensors EDfuse Hand Device

6 EDfuse CAN Interface The EDfuse CAN interface takes over several central functions at once. It's main task is to combine the different EDfuse modules and provide obtained information either to the EDfuse hand device or external data loggers. Up to eight low-volt sensors for detecting current or voltage can be connected to the CAN interface. They are individually galvanically separated. Using the EDfuse hand device or an external data logger, the incoming information is processed further. As a user, you are therefore free to choose the data storage device. The number of measurement points can be increased to up to 200 by connecting several CAN interfaces (maximum 25). It is therefore possible to detect currents and voltages throughout the whole vehicle in all installation positions. The configuration of measurement points on the respective CAN interfaces takes place via EDfuse configurator software using the USB interface or the EDfuse hand device. Due to the widely detected operating voltage and temperature range, use in all areas of the vehicle is guaranteed without loss of function - including during operation. CAN interface technical specification: Temperature range between -40 C and +85 C (-40 F an d 185 F) Connection of up to 8 sensors Galvanic separation of individual sensors Robust construction suitable for the workshop Configuration using the hand device or PC software Weight: ca. 650 g (1.4 lb) Connection options for CAN interface Connection options for high-current sensors Operating voltage 9 to 36 V (external power supply) Protection class IP 54 CAN-Interface

7 EDfuse shunt 300A The EDfuse shunt expands the EDfuse family by current measurement in interruptible electrical circuits. Therefore the shunt is integrated into the electrical circuit directly and allows a recording of measurement values analogously and in combination with other sensors. The EDfuse shunt can be used either directly to the handheld or in conjunction with the CAN interfaces. EDfuse Shunt Shunt low-volt technical specification: EDfuse Shunt low-volt measurement range: -300 A to +300 A DC continuous load A to A DC temporary resolution : up to 1 ma operating temperature of -40 C to +85 C (-40 F and +185 F) scanning frequency up to 1 khz measurement accuracy better than 1%

8 EDfuse clamp-on ammeter 30A/1000A The EDfuse clamp-on ammeter opens up the possibility to measure currents to 30A or to 1000A, without having to undo the electrical circuit. This measurement procedure is suitable also for highvolt applications. Various vehicle conditions and in particular error situations can be analyzed in combination with other EDfuse sensors. EDfuse clamp-on ammeter 30A 1000A Technical specification Clamp-on ammeter 30 A: measurement range from -30 A to +30 A scanning frequency up to 1 khz resolution: ±1mA measurement accuracy: ±1% operating temperature: 0 C to 50 C (32 F to 122 F) pliers opening up: 25mm battery life: 30h continuous operation Technical specification Clamp-on ammeter 1000 A: measurement range from A to A scanning frequency up to 1 khz resolution: ±500mA measurement accuracy: ±1% operating temperature: 0 C to 75 C (32 F to 67 F) pliers opening up: 32mm battery life: 50h continuous operation

9 EDfuse high-volt current and voltage sensor With the development of current sensors in the high-volt range, the EDfuse is perfectly equipped for the automobile future of electric and hybrid vehicles. The detection of electrical factors works for you as a user in the same way as the sensors in the low-volt range. As an independent module, the high-volt and the high-current sensor are either directly used on the hand device or in combination with the CAN interfaces. Measurements in mixed operations can also be performed with these modules. This means that equipment which combines both low-volt and high-volt ranges is easy to realize with EDfuse. High-volt technical specification: EDfuse high-volt current sensor Measurement range : A to A DC Resolution : 1 ma For use in high-volt systems up to 1000 V DC (galvanic isolation) Operating temperature of -40 C to +85 C (-40 F and 185 F) Scanning frequency up to 1 khz High-volt connections on request according to customer requirements Measurement accuracy better than 1,5 % Current sensor for high-volt applications EDfuse high-volt voltage sensor Measurement range : V bis V DC Resolution : 1 mv For use in high-volt systems up to 1000 V DC (galvanic isolation) Operating temperature of -40 C to +85 C (-40 F and 185 F) Scanning frequency up to 1 khz High-volt connections on request according to customer requirements Measurement accuracy better than 1%

10 EDfuse low-volt measurement fuses The EDfuse measurement fuses MINI, ATO and MAXI are plugged instead of the vehicle fuse. The sensors take over measurement of the quiescent and operating currents as well as the modules protected by the fuse in the current path. Replacement of the sensors to measure quiescent currents and operating currents is not necessary. The same sensor guarantees both measurements with high accuracy. Measurement takes place using the original safety wire. You therefore always have the additional fuse function even when the system is not in the measurement mode and there is never an additional resistance in the circuit like on a standard current shunt. The fuse wire itself is used to measure the shunt voltage. MINI, ATO, MAXI technical specification: Temperature range between -40 C and +85 C (-40 F and 185 F) Available in all fuse sizes Measurement takes place using original fuse wire Scanning rate: max. 1 khz per sensor. Resolution: 4µA/Bit to 265 µa/bit, depending on sensor current ampere rating. Accuracy: better than 1% in the operating current range. Different parameters can be stored in each sensor which simplify the measurement analysis Low-volt current sensors

11 EDfuse low-volt voltage sensor The EDfuse voltage sensor offers a simple opportunity to detect voltages such as battery voltage, synchronized with the obtained current values. This allows you, as a user, to identify errors in the electronics caused by lower voltages in the vehicle. The overall picture of the energy flow in the vehicle is therefore represented. Low-volt voltage sensor Technical specification: Measurement range between -100 and +100 V Sample frequency up to 1 khz Resolution depending on sample rate between 0.2 mv/bit and 1.7 mv/bit Measurement error less than 0.5% Galvanix seperated Low-volt voltage sensor

12 EDfuse HiL-module The EDfuse HiL-module is an all-purpose, autarkical current measurement system for the use in hardware in the loop test beds. Whether components-hil, system-hil or complete vehicle HiL, you can use this measurement system for all sorts of applications in typical 19-inch racks. The application is rather simple. You have to place the EDfuse HiL-module in a free slot, feed to the supply voltage internally via a separate connector and thus, the current measurement system is ready for the use on the hardware side. The measurement system is parameterized with the enclosed configurator software via the USB existing at the front so that you can record current courses very exactly, time synchronously and in a broad range of measurement on eight channels by the use of this module to the current recording during your system tests. You can optionally configure the current measurement modules for different measurement ranges and fitting sizes. The use of up to 10 current measuring modules makes measurements possible simultaneously with up to 80 channels. The sampling rate of up to 1 khz per channel creates a detailed representation. With the logging of the measuring data via the frontal CAN you have a universal interface for the data recording and therefore you can process the incoming information in your HiL main system without further ado. By the open CAN protocol it is possible for you to process the data at any time compatible to other records. Also precise measurements in systems with different supply voltage are ensured by the integrated galvanic isolation of all measuring elements with each other. In addition it is possible to run the EDfuse HiL module as a self-sufficient measurement system with the optional EDfuse handheld or an external data logger. HiL-module Technical specification HiL-module supply Voltage U sup : 9 V to 36 V sampling rate: max. 1 khz per sensor, 8 khz cumulative sampling rate measurement accuracy: better than 1 % at operating current Measuring channels galvanic isolated Frame size: height 6 HE, wide 10 TE, further sizes on request customizable 8 channels per card, expendable on up to 10 current measuring modules Data format: Standard CAN, 1 Mbit, ID optional configurable Measurement ranges: 2 A, 5 A, 25 A higher measurement ranges on request resolution: 4 µa/bit to 265 µa/bit, depending on the measurement range

13 EDfuse temperature sensor Temperatures of -40 C to +105 C (-40 F to 221 F) ca n be taken up parallel to the usual current and voltage measurements of your EDfuse system by the EDfuse temperature sensor. Applications, such as the analysis of the current consumption within a climatic chamber cycle, therefore become possible. The temperature sensors can be integrated several times in a system configuration and therefore they offer the possibility to take measurements at different positions and exhibits. EDfuse temperature sensor Technical specification temperature sensor: working temperature: -40 C to 200 C sensor (-40 F to 392 F) -40 C to 105 C electronics (-40 F to 221 F) resolution: 0,1 K scanning frequency up to 1 khz measurement accuracy: ± 0,4 K + 0,002 T uncalibrated ± 0,1 K + 0,0017 T calibrated

14 EDfuse battery module The EDfuse battery module can be used for independent energy supply of the EDfuse measurement system and further measurement technology. The measurement time period and therefore the recording of data can be extended with the use of this module. With a battery capacity of 42 Ah and an integrated charger as well as additional connections for the supply of external units with a 12 V supply voltage, the battery module is more than "just" a battery case. It is possible to measure for 8 hours continuously with the maximum version of the battery module using 25 CAN interfaces and 200 measurement points. A configuration example with a CAN interface, the hand device and 8 measurement points allows a measurement of approx. 1 week. With the "Break-Out function" it is particularly easy to extract the CAN messages from the measurement internal CAN Bus using the battery module. A Break-Out function with all EDfuse signals in contained in the battery module (CAN, enable signal).the enable signal can be used to issue an impulse for the start of measurements. Battery module technical specification 42 Ah battery capacity 12 V supply voltage 12 V connection (power socket) Break-Out function (CAN) Charger with 3A charging current Digital display of battery State of Charge Integration in measurement equipment Additional storage space for transport of EDfuse measurement technology Weight: ca. 20 kg (44 lbs) Fixing options in the vehicle for safe transport Comfortable transportation of the case thanks to the "trolley" design with wheels Battery module

15 Contact Technical: Dipl. Inf. Benjamin Diegelmann Product Manager SE E/E Commercial: Dipl. Ing. Oliver Findeis Key Account Manager PD E/E Tel: +49(0)661 / oliver.findeis@edag.de Tel.: +49(0)661 / EDAG GmbH & Co KGaA Reesbergstrasse 1 D Fulda Jennifer Rajala Head of E/E jennifer.rajala@edag-us.com Tel: / EDAG Inc. 275 Rex Blvd Auburn Hills, MI, USA

NTC/PTC- SIMULATION NTCS channel version

NTC/PTC- SIMULATION NTCS channel version NTC/PTC- SIMULATION 2-channel version MORE SAFETY AND CONTROL FOR YOUR DEVELOPMENT. Efficiency, reliability and safety of modern lithium ion batteries for electric vehicle drives strongly depend on the

More information

Electronic SUNSTAR & 传感与控制 Software TEL: FAX: KiBox To Go Measurement and Ev

Electronic SUNSTAR & 传感与控制 Software   TEL: FAX: KiBox To Go Measurement and Ev Electronic SUNSTAR & 传感与控制 Software http://www.sensor-ic.com/ TEL:0755-83376549 KiBox To Go Measurement and Evaluation System for Combustion Analysis in Test Vehicles with KiBox Cockpit Software The KiBox

More information

Introduction. Chapter 2

Introduction. Chapter 2 The Vantage PRO unit (Figure 2-1) combines a digital and graphing multimeter, lab scope and ignition scope with a powerful diagnostic database. Figure 2-1 Vantage PRO This diagnostic database gives you

More information

BMS: Installation Manual v2.x - Documentation

BMS: Installation Manual v2.x - Documentation Page 1 of 7 BMS: Installation Manual v2.x From Documentation This section describes how external peripheral devices are connected and additional functions of the BMS are used. I you have not done so already,

More information

Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition

Electronic Multi-channel Load PMLA. 150 W / 600 W 40 V up to 240 V 1 A up to 120 A. Preliminary Edition Electronic Multi-channel Load PMLA 150 W / 600 W 40 V up to 240 V 1 A up to 120 A Preliminary Edition Functionality Interface Overview Master RS-232 X CAN O USB X Analog O LAN X Analog isoliert / GPIB

More information

User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY!

User Manual INSTRUCTIONS FOR QUALIFIED PERSONNEL ONLY! Telemetrie-Messtechnik Schnorrenberg User Manual CTP8-Rotate 8 (4) channel telemetry for rotating applications like wheels or rotors, high signal bandwidth, 16bit, software programmable INSTRUCTIONS FOR

More information

Abstract. GLV User Manual 1

Abstract. GLV User Manual 1 GLV User Manual 1 Abstract This user manual is a high level document that explains all operational procedures and techniques needed to operate the GLV system in a safe and effective manner. Anyone operating

More information

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories

PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories Mini Clamps: Part Number 111.7015 PQ-Box 100, 150, 200 & 300 Power Quality Analyser Clamps & Accessories Description 10 ma-to-20 A or 100 ma-to-200 A. Switchable range mini clamp. 40 Hz 20 khz 4 x mini

More information

Energy Management System. Operation and Installation Manual

Energy Management System. Operation and Installation Manual Energy Management System Operation and Installation Manual AA Portable Power Corp 825 S 19 TH Street, Richmond, CA 94804 www.batteryspace.com Table of Contents 1 Introduction 3 2. Packing List 5 3. Specifications

More information

AC/DC Peak Voltmeter, Types MU17 and MU18

AC/DC Peak Voltmeter, Types MU17 and MU18 HIGHVOLT Prüftechnik Dresden GmbH Marie-Curie-Straße 10 01139 Dresden, Phone +49 351 845 700 Fax +49 351 845 679 E-mail sales@highvolt.de Web http://www.highvolt.de Data Sheet 5.56/7 AC/DC Peak Voltmeter,

More information

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles

KiBox To Go. Electronics & Software. Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles Electronics & Software KiBox To Go Measurement and Evaluation System for Combustion Analysis on Test Benches and in Vehicles Type 2893A... with KiBox Cockpit Software The KiBox is a complete combustion

More information

Precise results in record time.

Precise results in record time. Precise results in record time. AVL DITEST SCOPE Precision automotive measurement device FUTURE SOLUTIONS FOR TODAY The quickest way to reliable results. AVL DITEST SCOPE AUTOMOTIVE MEASUREMENT UNITS T

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels 4 additional analog

More information

VariTrans P Standard-Signal Isolators

VariTrans P Standard-Signal Isolators VariTrans Standard-Signal Isolators Warranty Defects occurring within 5 years from delivery date shall be remedied free of charge at our works (carriage and insurance paid by sender). The professional

More information

Photovoltaik ON GRID / OFF GRID

Photovoltaik ON GRID / OFF GRID Photovoltaik ON GRID / OFF GRID BST the flexible training system from for building automation based on real components. BST mobile practical safe elabo-ts.com Photovoltaic Off Grid System DC Hybrid AC

More information

aentron Energy System 1 to 900 Vdc

aentron Energy System 1 to 900 Vdc aentron Energy System 1 to 900 Vdc The aentron lithium-ion energy system enables the realisation of a modular and scalable lithium-ion battery solution. The management of large lithium-ion batteries systems

More information

SCP for Plastics Processing

SCP for Plastics Processing Measure & Analyze MCS SCP for Plastics Processing Modules for Signal Conditioning System Type 2853A..., 2207A..., 5063A..., 5227A..., 5613A... The SCP is a modular system for conditioning measuring signals

More information

Circuit Breaker Analyzer & Timer CAT65

Circuit Breaker Analyzer & Timer CAT65 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

Orion Jr. Purchasing Guide Rev. 1.2

Orion Jr. Purchasing Guide Rev. 1.2 www.orionbms.com Orion Jr. Purchasing Guide Rev. 1.2 The Orion Jr. BMS is a low cost battery management system designed to manage low voltage lithium ion battery packs up to 48V nominal. The Orion Jr.

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

CBA 1000 CHARACTERISTICS

CBA 1000 CHARACTERISTICS Circuit Breaker Analyzer and Microhmmeter Circuit Breaker timing test set. Built-in 200 A microhmmeter. 16 timing channels. Up to 4 trip/close coils control. Motion and speed analyzer. Static and dynamic

More information

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 33. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

TANDO 700. High-precision measuring and analysis system for dissipation/power factor and capacitance

TANDO 700. High-precision measuring and analysis system for dissipation/power factor and capacitance TANDO 700 High-precision measuring and analysis system for dissipation/power factor and capacitance High-voltage insulation testing made safe, easy and reliable Why dissipation/power factor and capacitance?

More information

HiRES TRANSIENT RECORDER

HiRES TRANSIENT RECORDER HiRES TRANSIENT RECORDER n Measurement of voltage, current and other values n Exact measurements even in environments with very strong EMI n Reliable signal transmission via fiber optic cables n Sophisticated

More information

PAS 300, PROFIBUS Slave Interface Module

PAS 300, PROFIBUS Slave Interface Module Catalog 08 PROFIBUS-Components 27 PAS 300, PROFIBUS Slave Interface Module PROFIBUS PROFIBUS slave interfaces PROFIBUS slave module The PROFIBUS slave interface module PAS 300 from the Systeme Helmholz

More information

Circuit Breaker Analyzer & Timer CAT66

Circuit Breaker Analyzer & Timer CAT66 Safe and fast testing with BSG (Both Sides Grounded) Timing and motion measurement 6 timing channels (3x2) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer input channels

More information

Advantageous PLUS Technology for SITRAFFIC C800. Your Success is Our Goal. Industrial Solutions and Services

Advantageous PLUS Technology for SITRAFFIC C800. Your Success is Our Goal. Industrial Solutions and Services Industrial Solutions and Services Peripheral lamp switches and sensors for the traffic control units SITRAFFIC C800VP, C800VPX, C840VP, C840VPX Advantageous PLUS Technology for SITRAFFIC C800 Your Success

More information

ICCS Controllers Intelligent Control and Command Systems

ICCS Controllers Intelligent Control and Command Systems ICCS Controllers Intelligent Control and Command Systems Intelligent controllers for realization of functions in vehicles Powerful Versatile Easy to program Standardized ICCS Controllers Overview ICCS

More information

Functional Testing of Electric Vehicle Battery Management Systems (BMS) using a PXI Platform Grant Gothing Project Engineer Bloomy Controls U.S.A.

Functional Testing of Electric Vehicle Battery Management Systems (BMS) using a PXI Platform Grant Gothing Project Engineer Bloomy Controls U.S.A. Functional Testing of Electric Vehicle Battery Management Systems (BMS) using a PXI Platform Grant Gothing Project Engineer Bloomy Controls U.S.A. The Challenge: Design and develop a flexible and cost-effective

More information

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000

High-Voltage Isolation Amplifiers / Shunt Isolators. VariTrans P 42000 Universal high-voltage isolator. Input voltages up to Vin = ±3600 V. The Task In high-voltage systems, unipolar or bipolar voltage signals ranging from 100 V to 3600 V must be galvanically isolated and

More information

DRTS 33. The new generation of advanced three phase relay test set

DRTS 33. The new generation of advanced three phase relay test set The new generation of advanced three phase relay test set Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Local control with color display Simultaneously available:

More information

-mbms. Battery Management SYSTEM OVERVIEW. Automation, Connectivity and Electrification of Mobile Machines ELECTRIFICATION SOLUTIONS

-mbms. Battery Management SYSTEM OVERVIEW. Automation, Connectivity and Electrification of Mobile Machines ELECTRIFICATION SOLUTIONS Automation, Connectivity and Electrification of Mobile Machines ELECTRIFICATION SOLUTIONS SYSTEM OVERVIEW -mbms Battery-Management-System for Li-Ion Batteries Complete Solution Quick & Easy Integration

More information

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL

200 VA bis VA 10 V bis 80 V 2 A bis 320 A. Source-Sink NL 200 VA bis 3.120 VA 10 V bis 80 V 2 A bis 320 A NL AC, NL Series Interface overview RS-232 X USB X GPIB O LAN O System bus O Analog X Analog isolated O X Standard O Option / not available NL1V20C40 2-quadrant

More information

Hand-held thermometer Model CTH7000

Hand-held thermometer Model CTH7000 Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 Applications Precision thermometer for very accurate temperature measurements in a range of -200... +962 C Reference

More information

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument

ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. ALMEMO V7 Measuring Instrument ALMEMO V7 Measuring Instrument ALMEMO 202 ALMEMO professional measuring instrument, latest V7 generation with data logger function. Two measuring inputs for all digital ALMEMO D7 sensors. Special functions

More information

Portable Multi-Function Calibrator Model CEP6000

Portable Multi-Function Calibrator Model CEP6000 Calibration Technology Portable Multi-Function Calibrator Model CEP6000 WIKA Data Sheet CT 83.01 Applications Calibration service companies/service industry Instrument and control workshops Industry (Laboratories,

More information

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter

CBA 1000 Circuit Breaker Analyzer and MicroOhmmeter Circuit Breaker Analyzer and MicroOhmmeter Circuit Breaker timing test set. 16 timing channels. Up to 4 trip/close coils control. Motion and speed analyzer. Suitable for EHV, HV and MV circuit breakers.

More information

Circuit Breaker Analyzer & Timer CAT126

Circuit Breaker Analyzer & Timer CAT126 Circuit Breaker Analyzer & Timer CAT126 Robust design for field use Timing and motion measurement 12 timing channels (3x4) for main and resistive contacts 6 timing channels for auxiliary inputs 3 transducer

More information

MEASURING AND TESTING INSTRUMENTS

MEASURING AND TESTING INSTRUMENTS MEASURING AND TESTING INSTRUMENTS Whether measuring temperature, current or voltage testing the right measuring tool can facilitate the everyday work. If one wants to perform several measuring tasks at

More information

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. I/O expansion modules. Modules from the

THE SOLUTION. MFW product family OPERATING INSTRUCTIONS. I/O expansion modules. Modules from the Modules from the MFW product family 14.06.2004 I/O expansion modules Increasing the number of inputs and outputs of the MFW basic modules INFOwww.ees-online.de Table of contents 1 Applicability 3 2 General

More information

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE

WE CONNECT REAL WORLD STRUCTURAL MONITORING SMART SENSORS SOFTWARE CLOUD WIRELESS INTERFACE TO THE WE CONNECT REAL WORLD TO THE STRUCTURAL MONITORING SENSORS WIRELESS INTERFACE SOFTWARE CLOUD Rev.10 del 3/10/017 Redatto da: R&D e MKT Approvato da: CEO Smart structural WIRELESS Interface NI00 devices

More information

PI 500 Hand-held instrument for industry

PI 500 Hand-held instrument for industry PI 500 Hand-held instrument for industry The new PI 500 is an all-purpose hand-held measuring instrument for many applications in industry like e. g.: Flow measurement Pressure/vacuum measurement Temperature

More information

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION

MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION MICRO BURN IN PRODUCTS LISTED IN MODEL NUMBER ORDER FOLLOWED BY A BRIEF DESCRIPTION MODEL 102P 102R DESCRIPTION Floor Stand (Plane) Floor Stand (Modified) HTRB Burn-In System (diode) Component Burn-In

More information

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534

EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534 Product data sheet 5.1 92.047 EY-IO 534: I/O module, analogue inputs with galvanic isolation, modu534 How energy efficiency is improved SAUTER EY-modulo 5 technology: modular, fast and universal Features

More information

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation

IV-30 Operating Manual for Pulse Distributor Cassette with potential separation IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC

More information

Operating Instructions

Operating Instructions Operating Instructions for the WABCO Diagnostic Controller 446 300 320 0 with Program Card ECAS 4x2-A 446 300 521 0 or ECAS 6x2-A 446 300 527 0 or ECAS BUS-A 446 300 529 0 March 1996 Edition Copyright

More information

Demonstration Case BENNING DB 1

Demonstration Case BENNING DB 1 Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...

More information

Circuit Breaker Analyzer & Timer CAT-P

Circuit Breaker Analyzer & Timer CAT-P Circuit Breaker Analyzer & Timer CAT-P Portable (1,4 kg / 3.1 lbs) Internal battery power supply Online measurement (First trip test) Offline measurement DC voltage and DC current measurement Touch screen

More information

Analog Devices: 6B Series Backplanes : 6B Series : IOS Subsystems : Market Solutions

Analog Devices: 6B Series Backplanes : 6B Series : IOS Subsystems : Market Solutions Page 1 of 11 Search: Parametric Search Replacement Parts Search View Cart My Account Log Home > Other > IOS Subsystems > Contact Us P Product Categories Amplifiers and Comparators Analog to Digital Converters

More information

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters.

DRTS 64. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters. The new generation of advanced test equipment for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters

DRTS 66. The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters The new generation of advanced test equipments for Relays, Energy meters, Transducers and Power quality meters Testing all relay technologies: electromechanical, solid state, numerical and IEC61850 Manual

More information

Features. Description. Applications

Features. Description. Applications Description Features The electronic loads of the ZSAC series are optimized for the practical use in laboratories, manufacturing and quality control. Power: Voltage: Current: 400W... 12600W 260V... 440V

More information

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL

Technical documentation NLS-3000 NAVIGATION LIGHT CONTROL PANEL Technical documentation LIGHT CONTROL PANEL For use on seagoing vessels Change status Version Date Author Checked Remark 0.1 07.08.2008 STO HN 1. Edition Page 1 of 26 Table of contents 1. Application and

More information

LANGER EMV-TECHNIK. Operating instructions. CAN 100 Optical fibre probe. 1. Use 2

LANGER EMV-TECHNIK. Operating instructions. CAN 100 Optical fibre probe. 1. Use 2 LANGER EMV-TECHNIK Operating instructions CAN 100 Optical fibre probe Contents: Page 1. Use 2 2. Operation 2 2.1. Mechanical connection 2 2.2. Optical connection 3 2.3. Electrical connection 3 2.4. Using

More information

MULTICHANNEL DATA RECORDERS

MULTICHANNEL DATA RECORDERS MULTICHANNEL DATA RECORDERS Introduction ma + V / mv RTD + - universal inputs + - TC universal inputs: RTD + TC or U + I (SRD-99) fixed inputs: RTD, TC, U, I (SRD-N16) 2 relay outputs memory up to 3 000

More information

Handheld Micro Ohmmeters RMO-H series

Handheld Micro Ohmmeters RMO-H series Handheld Micro Ohmmeters RMO-H series Handheld only 0,95 kg / 2.1 lbs Powerful regulated current up to 300 A DC Automatic test current ramp Operated by high-capacity battery Measuring range 0,1 μω 2000

More information

WALKING TEST KIT WT5000

WALKING TEST KIT WT5000 reliable & caring since 1976 WALKING TEST KIT WT5000 Walking Test Kit, includes: a WT5000 electrometer, A/D converter with software, hand-held probe, connecting cables, conductive carrying case, user s

More information

Connect - Contact - Control. High Voltage Contactors. F 170e

Connect - Contact - Control. High Voltage Contactors. F 170e Connect - Contact - Control High Voltage Contactors F 170e 2 Contents Page 1.0. Application...3 2.0. Power Rating...3 3.0. Device Data...4 3.1. Electronic Contactor Type ZH 767E / 767F... 4 3.2. Contactor

More information

BERMAD Irrigation. BIC Wire RTU

BERMAD Irrigation. BIC Wire RTU BIC 2500 2-Wire RTU System guide Versions : 2007 Contents 1. System Overview 3 1.1. Technical SpecificationS 3 1.1. System ComponentS 4 2. Installation 5 2.1 Cable Test 5 2.2. Ground RodS 6 2.3 Addressing

More information

Redundant Power Supplies. Keep Machines Up When Power Goes Down

Redundant Power Supplies. Keep Machines Up When Power Goes Down Redundant Power Supplies Keep Machines Up When Power Goes Down When your operation is critical, you need power you can count on. Redundant Power Systems are ideal for any equipment where the highest attainable

More information

MID approval no. DE-08-MI004-PTB004 Date of release

MID approval no. DE-08-MI004-PTB004 Date of release 1. Identification Energy and Flow Computer Flow rate and energy calculator for liquids, gases and water steam E-DB-1000-700-01 MID approval no. DE-08-MI004-PTB004 Date of release 04.01.08 2. Area of Application

More information

Strain Gage Measuring Amplifier GSV-3

Strain Gage Measuring Amplifier GSV-3 Strain Gage Measuring Amplifier GS-3 Tel 03302 559 282, Fax: 03302 559 141, info@me-systeme.de, www.me-systeme.de 1 Strain Gage Measuring Amplifier GS-3 Description...4 Models...5 Measurement Resolution...5

More information

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load)

PROFITEST PV Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load) Peak Power Measuring Instrument and Curve Tracer for PV Modules and Strings (Measurement at Capacitive Load) 3-349-632-03 1/5.11 Generator voltage up to 1000 V DC, current up to 20 A DC Measurement of

More information

Circuit Breaker Analyzer & Timer CAT-P

Circuit Breaker Analyzer & Timer CAT-P Circuit Breaker Analyzer & Timer CAT-P Portable (1,4 kg / 3.1 lbs) Internal battery power supply Online measurement (First trip test) Offline measurement DC voltage and DC current measurement Touch screen

More information

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with

OPERATION MANUAL. SD card real time datalogger, RS232/USB PRESSURE METER. Model : PS-9303SD. Your purchase of this PRESSURE METER with SD card real time datalogger, RS232/USB PRESSURE METER Model : PS-9303SD Your purchase of this PRESSURE METER with S D C A R D DATALOGGER marks a step forward for you into the field of precision measurement.

More information

ALMEMO Measuring Instruments

ALMEMO Measuring Instruments ALMEMO 5690-1M09 and functions and functions, as for ALMEMO 5690 series Master measuring circuit, 9 ALMEMO input sockets, electrically isolated, suitable for 9 ALMEMO sensors Up to 9 ALMEMO connectors;

More information

A P P L I C A T I O N

A P P L I C A T I O N Circuit Breaker timing test set 16 timing channels Motion and speed analyzer Built-in 200 A microohmmeter Up to 4 trip/close coils control Static and dynamic contact resistance measurement Suitable for

More information

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory.

General information. Engineering with. Supply voltage. Load voltage L+ Input current. Power losses. Memory. Work memory. Product data sheet SIMATIC S7-300, CPU 314C-2DP COMPACT CPU WITH MPI, 24 DI/16 DO, 4AI, 2AO, 1 PT100, 4 FAST COUNTERS (60 KHZ), INTEGRATED DP INTERFACE, INTEGRATED 24V DC POWER SUPPLY, 64 KBYTE WORKING

More information

MODEL 9250 Preliminary data sheet

MODEL 9250 Preliminary data sheet Delivery: ex stock Warranty: 24 months Universal Instrumentation Amplifier for strain gage, potentiometric, DC/DC and incremental sensors MODEL 9250 Preliminary data sheet NEW burster TEDS Highlights Ultra-fast

More information

DBK48. Multipurpose Isolated Signal-Conditioning Module. Description. Supports up to Sixteen 8B Modules

DBK48. Multipurpose Isolated Signal-Conditioning Module. Description. Supports up to Sixteen 8B Modules DBK48 Multipurpose Isolated Signal-Conditioning Module Description 1 Safety Concerns 2 Hardware Setup 2 Installing 8B Modules 4 Installing Plug-in Resistors to Create 4 to 20 ma Loops 5 Making Terminal

More information

Hand-held thermometer Model CTH7000

Hand-held thermometer Model CTH7000 Calibration technology Hand-held thermometer Model CTH7000 WIKA data sheet CT 55.50 for further approvals see page 2 Applications Precision thermometer for very accurate temperature measurements in a range

More information

ICS Regent. Monitored Digital Input Modules 24 VDC (T3411) PD-6031

ICS Regent. Monitored Digital Input Modules 24 VDC (T3411) PD-6031 ICS Regent PD-6031 Monitored Digital Input Modules 24 VDC (T3411) Issue 1, March, 06 Monitored digital input modules provide input sensing for 16 field input devices. With a line monitor device installed

More information

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet

TURCK Process Automation IS Interface Technology. Interface Modules. IM Series Cabinet Process Automation IS Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to solve the problems associated with the

More information

ISAscale High Current Sensor Module For Electric Vehicles

ISAscale High Current Sensor Module For Electric Vehicles ISAscale High Current Sensor Module For Electric Vehicles 1 INTRODUCTION This User Manual describes use and operation of the ISAscale IVT-Modular high current sensor module for Electric Vehicles. The IVT

More information

HEW.E. High Rate Discharge Tester HEW

HEW.E. High Rate Discharge Tester HEW HEW.E High Rate Discharge Tester HEW High Rate Discharge Tester HEW 1. The Concept The High Rate Discharge Tester HEW is particularly designed for testing the cranking performance (cold and warm cranking)

More information

APPLICATION GUIDE. Interface Modules IM Series.

APPLICATION GUIDE. Interface Modules IM Series. Interface Modules IM Series APPLICATION GUIDE www.turck.com Interface Technology Interface Modules TURCK's IM series of Isolating Intrinsically Safe Barriers is designed to be a simple and safe way to

More information

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing.

VariTrans B The world s first 3-port standard signal isolator in a 6-mm modular housing. Standard-Signal Isolation Amplifiers The world s first 3-port standard signal isolator in a 6-mm modular housing. The Task Isolation and, if required, conversion of 0... 20 ma, 4... 20 ma, and 0... 10

More information

ICS Regent. Guarded Analog Output Modules. 4 to 20 ma (T3480) PD-6026

ICS Regent. Guarded Analog Output Modules. 4 to 20 ma (T3480) PD-6026 ICS Regent PD-6026 Guarded Analog Output Modules 4 to 20 ma (T3480) Issue 1, March, 06 Guarded analog output modules provide 4 to 20 ma current outputs for a maximum of six user loads per module. These

More information

MBM - Modular I/O system IP20

MBM - Modular I/O system IP20 - Modular I/O system IP20 Input/output module digital 4-way Ordering data 4 digital inputs and outputs 55882 3-wire screw terminal block 55832 3-wire spring clamp terminal block 55852 Load weight 1) 1.00

More information

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement

CALYS 50. Field multifunction calibrator for basic use. Calibration measurement for basic use Description is a basic multifunction calibrator within CALYS range. It is the perfect tool for advanced process maintenance and use on test bench in all industries. Suitable for all field

More information

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24

DINALOG A 96 x 24. Programmable quasi-analogue bar graph meters. Technical characteristics DINALOG A 96 x 24 Bar graph displays For process control, automation, and laboratory applications Current, voltage, resistance, frequency and temperature Up to 0.5% resolution DINALOG A 96 x 24 Programmable quasi-analogue

More information

AVL ELECTRIFICATION TEST SOLUTIONS

AVL ELECTRIFICATION TEST SOLUTIONS AVL ELECTRIFICATION TEST SOLUTIONS E-INTEGRATION TEST SYSTEM Mario Propst AVL List GmbH (Headquarters) CONTENT o Applications o System solutions o Product solutions o Use cases o Customer References Mario

More information

DC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling

DC-204R DC-204Ra SMART DYNAMIC STRAIN RECORDER. 200kHz 2GB UPS. Strain DC voltage Temperature. TML Pam E-442B. capacity. High speed sampling TML Pam E-442B SMART DYNAMIC STRAIN RECORDER Standard With analog output DC-204R DC-204Ra Strain DC voltage Temperature High speed sampling 200kHz Large data recording 2GB capacity Automatic data storing

More information

DREAM 2 WIRED RTU SYSTEM GUIDE

DREAM 2 WIRED RTU SYSTEM GUIDE TALGIL COMPUTING & CONTROL LTD. NAAMAN CENTER, HAIFA - ACCO ROAD ISRAEL P.O. BOX 775 KIRYAT MOTZKIN 26119 TEL: 972-4-8775947-8775948 FAX: 972-4-8775949 DREAM 2 WIRED SYSTEM GUIDE 2007 1 CONTENTS 1. SYSTEM

More information

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200

Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 Accessories for the mobile Power Quality Analyzers PQ-Box 100 & 150 & 200 05-2017 Accessories for PQ-Box 100 & 150 & 200 Page 1 Rogowski coil set CAT IV 600V Current range: 1A to 3000A RMS; Accuracy: 1%

More information

Clamp meter with Data recorder SERIES set

Clamp meter with Data recorder SERIES set Clamp meter with Data recorder SERIES set UPCB-03 (Included) Optional Hard carrying case CA-08 Clamp meter with Data recorder set /DL-9602SD SET * Complete set are includes : 1. Clamp meter CM-9930R. 2.

More information

Laboratory automation

Laboratory automation Siemens AG 2008 Laboratory automation /2 SIMATIC PCS 7 LAB: Compact control system for the laboratory automation Siemens ST PCS 7.1 Update October 2008 Laboratory automation Siemens AG 2008 Overview PCS

More information

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM

OBSOLETE. Isolated, Linearized, Thermocouple Input 3B47 FEATURES APPLICATIONS PRODUCT OVERVIEW FUNCTIONAL BLOCK DIAGRAM FEATURES Interfaces, amplifies, filters, isolates, & linearizes analog input voltages from a J, K, T, E, R, S or B-type thermocouple Thermocouple input signal is internally linearized High accuracy internal

More information

ACR8000 Hardware Manual

ACR8000 Hardware Manual p/n YPM08119 Automation ACR8000 Hardware Manual Effective: October 7, 2002 This page intentionally left blank. ACR8000 Hardware Manual P/N PM08119 Version Change: From: Version 1.02, Dated 7/8/1999 To:

More information

PROGRAMMABLE DC ELECTRONIC LOAD MODEL 6310A SERIES MODEL 6310A SERIES. Programmable DC Electronic Load. Key Features:

PROGRAMMABLE DC ELECTRONIC LOAD MODEL 6310A SERIES MODEL 6310A SERIES. Programmable DC Electronic Load. Key Features: Programmable DC Electronic Load MODEL 6310A SERES Key Features: PROGRAMMABLE DC ELECTRONC LOAD MODEL 6310A SERES The Chroma 6310A series Programmable programmable parameters include: slew rate, DC Electronic

More information

SAT BMS. User Guide. Rev

SAT BMS. User Guide. Rev SAT BMS User Guide Rev001. 2015.11 CONTENTS 1 SAFETY... 3 1.1 General guidance... 3 2 SAT BMS Introduction... 4 2.1 General overview... 4 2.2 BMS General wiring structure... 4 2.3 Hardware... 4 2.4 Program...

More information

imc BUSDAQflex compact mobile expandable Intelligent multi-bus data logger for field and vehicle buses imc productive testing

imc BUSDAQflex compact mobile expandable Intelligent multi-bus data logger for field and vehicle buses imc productive testing imc BUSDAQflex compact mobile expandable Intelligent multi-bus data logger for field and vehicle buses imc productive testing www.imc-berlin.com/busdaq imc BUSDAQflex at a glance Provides 2 to 12 CAN nodes

More information

CONTROL CABINET KR C1 A. Technical Data. KRC1A_Tech.Dat en. 1of 11

CONTROL CABINET KR C1 A. Technical Data. KRC1A_Tech.Dat en. 1of 11 CONTROL CABINET KR C1 A Technical Data 1of 11 e Copyright KUKA Roboter GmbH This documentation or excerpts therefrom may not be reproduced or disclosed to third parties without the express permission of

More information

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server

NI2400/NI816/NI4866 DATALOGGER NI2400/NI816/NI /16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATALOGGER NI2400/NI816/NI4866 8/16/24 CHANNEL ETHERNET DATA LOGGER with Embedded Web Server DATASHEET Rev. 08 del 08/10/2018 Redatto da R&D Approvato da MKT GENERAL 1SPECIFICATIONS NI4866 NI816 NI2400

More information

Operation Manual of Smart Battery Systems (SBS) with SmBus V1.1 support for 12.8V LiFePO4 battery pack (6.6Ah-100Ah)

Operation Manual of Smart Battery Systems (SBS) with SmBus V1.1 support for 12.8V LiFePO4 battery pack (6.6Ah-100Ah) Operation Manual of Smart Battery Systems (SBS) with SmBus V1.1 support for 12.8V LiFePO4 battery pack (6.6Ah-100Ah) AA Portable Power Corp (http://www.batteryspace.com) Address: 860 S, 19 th St, Unit

More information

RT4F-120V/20A-WAC RECTIFIER

RT4F-120V/20A-WAC RECTIFIER The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with

More information

Excel Power Distribution

Excel Power Distribution www.excel-networking.com Excel Power Distribution Section 7 In this Section: Pages Power Distribution Units 154 Efficiency Measurements 154 Excel Modular PDU Range 155 Excel Standard PDUs 156 Excel Intelligent

More information

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017

ICS Regent. Relay Output Modules. Low Power and High Power (T3446L and T3446H) PD-6017 ICS Regent PD-6017 Relay Output Modules Low Power and High Power (T3446L and T3446H) Issue 1, March, 06 Relay output modules provide control of eight user output loads. Two types of relay output modules

More information

Programmable D.C. Electronic Load

Programmable D.C. Electronic Load Programmable D.C. Electronic Load D35 PEL-2004 PEL-2002 FEATURES NEW NEW * Sequence Function to do High Speed Load Simulations * Flexible Configuration with Mainframes and Plug-in Modules * Multiple Independent

More information

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X

PolluTherm. calculator hous. 2 from hous. 1 until X X X X X* X* M-Bus- M-Bus and 2 2PM pulse inputs X X X X 1. Use of the option modules There are two different housings with which these same plug-in units can be used namely: Calculator housing 1 (PolluTherm, PolluStat E and PolluFlow 2010) indicated by a lid

More information