RM238 Series. Rackmount Chassis User Manual. January 2019 Version 1.0

Size: px
Start display at page:

Download "RM238 Series. Rackmount Chassis User Manual. January 2019 Version 1.0"

Transcription

1 Rackmount Chassis User Manual January 2019 Version 1.0 A document provides an overview of product features, functions, architecture, and support specifications

2 DISCLAIMERS No license (express or implied, by estoppel or otherwise) to any intellectual property rights is granted by this document. Chenbro disclaims all express and implied warranties, including without limitation, the implied warranties of merchantability, fitness for a particular purpose, and non-infringement, as well as any warranty arising from course of performance, course of dealing, or usage in trade. This document contains information on products, services and/or processes in development. All information provided here is subject to change without notice. Contact your Chenbro representative to obtain the latest Configuration Guide. The products and services described may contain defects or errors known as errata which may cause deviations from published specifications. Current characterized errata are available on request. Chenbro, and the Chenbro logo are trademarks of Chenbro Micom Co.,Ltd in the worldwide. *Other names and brands may be claimed as the property of others 2018 Chenbro Micom Co.,Ltd. <Table of Contents 2

3 Table of Contents Table of Contents... 3 List of Figures... 4 List of Tables Product Overview System Features Overview Front Panel Back Panel Front Control Panel Storage Configurations Chassis Dimensions Available Rack Mounting Kit Options (Refer to Installation ) System Level Environmental Specifications System Packaging Installation Top Cover Removal and Installation HDD Cage Removal and Installation Hot-swap HDD Assembly Removal and Installation Internal 2.5 HDD Removal and Installation Internal Slim ODD Removal and Installation System Maintenance Fan Assembly Removal and Installation x 2.5 Hot-swap Drive Cage Installation (Back Panel) Full Height PCI-e Card Installation PSU Installation Slide Rail Installation Backplane Storage Backplane Options Port 12Gb/s SAS Passive Backplane Port 12Gb/s SAS Passive Backplane Port 12Gb/s SASActive Backplane x 2.5 Drive Bay Accessory Kit Port 12Gb/s SAS Passive Backplane Port 12Gb/sSAS Passive Backplane Docked with Expander board Port SATA/SAS/NVMe (4 x Tri-mode) Passive Backplane Port PCIe Gen3NVMe Passive Backplane Maintenance and Service <Table of Contents 3

4 List of Figures Figure 1 RM23808 overview... 9 Figure 2 RM23812 overview... 9 Figure 3 RM23824 overview... 9 Figure 4 RM23808 major components overview Figure 5 RM23812 major components overview Figure 6 RM23824 major components overview Figure 7 RM23808 front panel Figure 8 RM23812 front panel Figure 9 RM23824 front panel Figure 10 Back panel with single PSU Figure 11 Back panel with redundant PSU Figure 12 Front control panel Figure 13 8 x 3.5 front drive bay configuration Figure x 3.5 front drive bay configuration Figure x 2.5 front drive bay configuration (24 x SATA/SAS) Figure x 2.5 front drive bay configuration (4 x NVMe + 20 x SATA/SAS) Figure x 2.5 front drive bay configuration (8 x NVMe + 16 x SATA/SAS) Figure x 2.5 front drive bay configuration (20 x NVMe + 4 x SATA/SAS) Figure x 2.5 front drive bay configuration (24 x NVMe) Figure 20 Chassis dimensions Figure 21 Label emboss dimensions Figure 22 Rear top cover removal Figure 23 Front top cover removal Figure 24 Front top cover installation Figure 26 HDD cage removal Figure 27 HDD cage installation Figure hot-swap HDD assembly removal Figure hot-swap HDD assembly installation Figure HDD removal Figure HDD installation Figure " hot-swap HDD assembly removal Figure Hot-swap HDD assembly installation Figure HDD removal Figure HDD installation Figure HDD removal in 3.5 tray Figure HDD installation in 3.5 tray Figure 38 Internal 2.5'' HDD removal (RM23808) List of Figures 4

5 Figure 39 Internal 2.5'' HDD installation (RM23808) Figure 40 Internal slim ODD removal (RM23808) Figure 41 Internal slim ODD installation (RM23808) Figure 42 Removal of whole system from the rack Figure 43 Installation of whole system into the rack Figure 44 Fan assembly removal Figure 45 Fan assembly installation Figure 46 Fan module removal Figure 48 Air baffle removal Figure 49 Air baffle installation Figure 50 2 x 2.5'' drive cage bracket installation (back panel) Figure 51 2 x 2.5'' drive cage installation (back panel) Figure 52 2 x 2.5 drive cage backplane installation (back panel) Figure 53 Full height back panel bracket Figure 54 Riser card and bracket installation Figure 55 Single 2U PSU installation Figure 56 Redundant PSU cage assembly Figure 57 Redundant PSU cage installation Figure 58 CRPS module installation Figure 59 CRPS module removal Figure 60 Slide rail installation-1 ( B0) Figure 61 Slide rail installation-2 ( B0) Figure 62 Slide rail Installation-3 ( B0) Figure 63 Slide rail Installation-4 ( B0) Figure 64 Drive tray LED identification Figure Port SATA/SAS passive backplane device side Figure Port SATA/SAS passive backplane host side Figure Port SATA/SAS passive backplane device side Figure Port SATA/SAS passive backplane host side Figure 69 12G Mini SAS HD Port Active Backplane front view Figure Port SATA/SAS active backplane host side Figure '' 2-bay drive module Figure '' 2-Port SATA/SAS passive backplane device side Figure '' 2-port SATA/SAS passive backplane host side Figure '' 2-Port NVMe passive backplane device side Figure '' 2-port NVMe passive backplane host side Figure Port SATA/SAS passive backplane device side Figure Port SATA/SAS passive backplane host side Figure Port SATA/SAS passive backplane device side Figure Port SATA/SAS passive backplane host side List of Figures 5

6 Figure 80 Expander board back view Figure 81 Expander board front view Figure '' 8-port SATA/SAS/NVMe Backplane front view Figure '' 8-port SATA/SAS/NVMe passive backplane host side Figure '' 8-port NVMe passive backplane device side Figure '' 8-port NVMe passive backplane host side List of Figures 6

7 List of Tables Table 1 Chenbro RM23808/12/24 Specifications... 8 Table 2 Front control panel Table 3 Slide rail options Table 4 System environmental specifications summary Table 5 System packaging information Table 6 Product weight information Table 7 Drive power LED/activity LED behavior Table Port SATA/SAS passive backplane Table 9 Connector description for port SATA/SAS passive backplane Table 10 Fan Setting for RM Table Port SATA/SAS passive backplane Table 12 Connector description for port SATA/SAS passive backplane Table 13 Dip Switch Setting Table Port SATA/SAS active backplane Table 15 Connector description for port SATA/SAS active backplane Table 16 Dip Switch Setting Table 17 Fan Setting for RM Table 18 Solution and operating condition for bay drive module Table Port SATA/SAS passive backplane Table 20 Connector description for port SATA/SAS passive backplane Table Port NVMe passive backplane Table 22 Connector description for port NVMe passive backplane Table Port SATA/SAS passive backplane Table 24 Connector description for port SATA/SAS passive backplane Table 25 Dip Switch Setting Table Port SATA/SAS Passive Backplane Table 27 Connector description for port SATA/SAS passive backplane Table 28 12Gb/s expander board Table 29 Connector description for expander board Table 30 Dip Switch Setting Table " 8-port SATA/SAS/NVMe (4 x Tri-mode) passive backplane Table 32 Connector description for port SATA/SAS/NVMe passive backplane Table Port NVMe passive backplane Table 34 Connector description for port NVMe passive backplane List of Tables 7

8 1. Product Overview This RM238 Series offers a variety of system options to meet the varied configuration requirements of high-density/high-performance computing environments. This 2U chassis supports both 2.5 and 3.5 storage form factors with different drive bay configurations. This chapter provides a high-level overview of the system features and available options as support for different storage configurations within this product series. More detail for each major component, feature, or option is provided in the following chapters. Feature Table 1 Description Chenbro RM23808/12/24 Specifications M/B Form Factor ATX (12 x 9.6 ) / CEB(12 x 10.5 )/ E-ATX (12 x 13 ) Dimension (D x W x H) Drive Bay 660mm x 438mm x 87mm 26 x 17.2 x 3.4 RM23808: 8 x 3.5 Hot-swap, 2 x 2.5 Internal, 1 x Slim ODD, 2 x 2.5 Hot-swap (rear, option) RM23812: 12 x 3.5 Hot-swap, 2 x 2.5 Hot-swap (rear, option) RM2324: 24 x 2.5 Hot-swap, 2 x 2.5 Hot-swap (rear, option) Backplane SATA/SAS: 12Gb/s Active or Passive BP, SGPIO, I2C NVMe: PCIe Gen3 Passive BP, I2C Power Supply Indicator Front Control Front I/O System Security System Fan Expansion Slot Front Bezel Rail Kit 1+1 CRPS or Single 2U 1 x Power Status, 2 x LAN Activity, 1 x UID, 1 x System Status, 1 x HDD Status Power On/Off, UID, System Reset 2 x USB3.0 Intrusion Switch (option) Up to 6 Hot-swap Fans with 80mm Size 7 x Low Profile or 3 x Full Height Security Bezel w/ or w/o Lock (option) Tool-less Slide Rail Packaging Cubic Feet 3.29 Container Loading 20': 200, 40': 460, 40'H: 506 Product Overview/ 8

9 1-1 System Features Overview Figure 1 RM23808 overview Figure 2 RM23812 overview Figure 3 RM23824 overview Product Overview/ 9

10 Figure 4 RM23808 major components overview Figure 5 RM23812 major components overview Figure 6 RM23824 major components overview A. Front Top Cover B. Rear Top Cover C. Label Embossment D. Rear Top Cover Latch E. Internal 2.5 HDD Bays F. Fan Assembly G. Slim ODD Bay H. Server Board I. 2.5 HDD Hot-swap Cage J. Power Supply Unit Product Overview/ 10

11 1-2 Front Panel Figure 7 RM23808 front panel Figure 8 RM23812 front panel Figure 9 RM23824 front panel A. Front Control Panel B. Storage Drive Bay C. Info Tag D. Rack Handles E. Slim ODD Bay Product Overview/ 11

12 1-3 Back Panel Figure 10 Back panel with single PSU Figure 11 Back panel with redundant PSU A. Single 2U Power Supply B. CRPS Power Supply C. I/O Gasket D. Low Profile Expansion Slots E. 2 x 2.5 Hot-swap Drives Product Overview/ 12

13 1-4 Front Control Panel Figure 12 Front control panel Table 2 Front control panel Label ICON Indicator, button, or connector A B C Power Button UID Button Reset Button D USB 3.0 E F G H I HDD Activity LED System Alarm LED LAN1, LAN2 Activity LED Rack Handle (Left) Rack Handle (Right) Product Overview/ 13

14 1-5 Storage Configurations Figure 13 8 x 3.5 front drive bay configuration Figure x 3.5 front drive bay configuration Figure x 2.5 front drive bay configuration (24 x SATA/SAS) Product Overview/ 14

15 Figure x 2.5 front drive bay configuration (4 x NVMe + 20 x SATA/SAS) Figure x 2.5 front drive bay configuration (8 x NVMe + 16 x SATA/SAS) Figure x 2.5 front drive bay configuration (20 x NVMe + 4 x SATA/SAS) Figure x 2.5 front drive bay configuration (24 x NVMe) Product Overview/ 15

16 1-6 Chassis Dimensions Figure 20 Chassis dimensions Figure 21 Label emboss dimensions Product Overview/ 16

17 1-7 Available Rack Mounting Kit Options (Refer to Installation ) Advisory Note Available rack and cabinet mounting kits are not designed to support shipment of the server system while installed in a rack. If you chose to do so, Chenbro advises you to verify your shipping configuration with appropriate shock and vibration testing before shipment. Chenbro does not perform shipping tests which cover the complex combination of unique rack offerings and custom packaging options. Caution: Exceeding the specified maximum weight limit of a given rail kit or misalignment of the server in the rack may result in failure of the rack rails, causing damage to the system or personal injury. Two persons to operate or the use of a mechanical assist tool to install and align the server into the rack is highly recommended. Available rack mounting kits: Table 3 Slide rail options Part Number B0 (A ) 84H (3A02-599) Rail Dimension (mm/inch) 835/32.9" 599/23.6" Applicable Cabinet-Post to Post (mm/inch) 668~937/26.3"~36.9" 660~838/26"~33" 3 Section/2 Section 3 Section 2 Section Post to Post Distance (mm/inch) 668~937/26.3"~36.9" 660~838/26"~33" Traveling Distance (mm/inch) 782/30.8" 560/22.0" Support Chassis Width (mm) Loading (kg) 30.8kg 18.8kg Tool-less/Non Tool-less Tool-less Tool-less Support CMA Yes No Product Overview/ 17

18 1-8 System Level Environmental Specifications The following table defines the system level specifications under operating and non-operating environments. Parameter Table 4 System environmental specifications summary Specification Temperature Operating 5º C to 35º C (41º F to 95º F) Temperature Non-Operating -40º C to 70º C (-40º F to 158º F) Humidity Non-Operating 50% to 90%, non-condensing with a maximum wet bulb of 28 C (at temperatures from 25 C to 35 C) Unpackaged Shock Non-Operating Trapezoidal, 25 g, velocity change is based on product weight Unpackaged Vibration Operating g2/hz to g2/hz Input acceleration is 0.26 g RMS 10 minutes per axis for all 3 axes on all samples Random control limit tolerance is ± 3 db Sag & bow Non-Operating Tolerance analysis among rack, rail and chassis Actual on rack test with EIA Go-NoGo fixture EMI Pre-scan Radiated Emissions CISPR CLASS A (under 6dB): 30~1000 MHz vertical/horizontal 1G~6G GHz vertical/ horizontal 1G~18G GHz vertical/horizontal ESD Contact and Air Discharge Electrostatic Discharge Immunity Test IEC RVI Operating HDD class: Class 1: Highest performance, reliability, and data integrity Class 2: A second tier of performance, reliability, and data integrity HDD I/O throughput degradation SPEC Pass/Fail Criteria: No functional failure during test or post-test diagnostics. Requirement to pass test is based on IOMeter data throughput (in IO s per second) expressed as a percent of Test HDD maximum theoretical baseline performance Class1: > 90% of baseline for 4K random writes and > 80% of baseline for 128K sequential writes. Class2: > 85% of baseline for 4K random writes and > 75% of baseline for 128K sequential writes. Mix: > 80% of baseline for 4K random writes and > 70% of baseline for 128K sequential writes. Packaged Non-Operating ISTA (weight over 68 kg, 1B ; weight equal or less than 68 kg, 1A) Vibration Packaged Drop Non-Operating Drop height change is based on product weight Non-palletized product: Investigation: Test requirement is 6 face drops, 8 corner drops and 12 edge drops for a total of 26 drops. Validation: Test requirement is 6 face drops, 2 corner drops and 3 edge drops for a total of 11 drops. Palletized product: (Both investigation and validation) Perform two bottom drops at the specified height, 10 bottom drops at one half of the specified height. Perform 4 rotational edge drops (one per edge) at the specified height. Product Overview/ 18

19 1-9 System Packaging The original Chenbro packaging, where the server system is delivered, is designed to provide protection for L5 configuration and tested to meet ISTA (International Safe Transit Association) Test Procedure 1A (2008). The packaging is also designed to be reused for shipment after the system integration has been completed. The original packaging includes the shipping box, and various protective inner packaging components, which are designed to function together as a protective packaging system. When reused, all of the original packaging material must be used, including box and each inner packaging component. In addition, all inner packaging components MUST be reinstalled in the proper location to ensure adequate protection to the system for subsequent shipment. Table 5 System packaging information Part Number Single/ Bulk Form factor (mm) Support level A0 Single 830 x 590 x 190 L5 NOTE: The design of the inner packaging components does not prevent improper placement within the packaging assembly. There is only one correct packaging assembly that will allow the package to meet the ISTA (International Safe Transit Association) Test Procedure 1A (2008). Failure to follow the specified packaging assembly instructions may result in damage to the system during shipment. Product Un-packaged Net Weight (kg) Table 6 Product weight information Packaged Gross Weight (kg) Un-packaged Net Weight (lbs) Packaged Gross Weight (lbs) RM RM RM NOTE: An L5 system does not include M/B, processors, memory, drives, or add-in cards. It is the system configuration as shipped from Chenbro. Weights of integrated system (system configurations that include the items above) will vary depending on the final system configuration. Product Overview/ 19

20 2. Installation RM238 series supports a variety of different storage options: Up to 8 x 3.5 hot-swap HDD or 2.5 HDD/SSD (RM23808) Up to 12 x 3.5 hot-swap HDD or 2.5 HDD/SSD (RM23812) Up to 24 x 2.5 hot-swap HDD/SSD (RM23824) 2 x 2.5 hot-swap SATA SSD [7mm or 9.5mm thickness] or NVMe SSD[7mm or 15mm(x1) thickness with upgrade kit] Support for different storage and peripheral options will vary depending on the system model and/or available accessory options installed. / Installation 20

21 2-1 Top Cover Removal and Installation Figure 22 Rear top cover removal 1. Loosen 2 screws on the rear top cover. 2. Pull the latch as shown to release the cover. 3. Remove it vertically by both hands to hold each side. Figure 23 Front top cover removal 1. Press 2 buttons with your 2 thumbs on the cover without release. 2. Slide the cover as shown and remove it vertically. / Installation 21

22 Figure 24 Front top cover installation 1. Align the guide pins of this cover with the grooves on the chassis base. (3 guide pins for both side) 2. Slide this cover toward the front panel until it clicks. Figure 25 Rear top cover installation 1. Align the guide pins of the rear top cover with the grooves on the chassis base. (4 guide pins for both side) 2. Install the cover vertically as shown, and press the latch to lock. 3. Secure with two screws. / Installation 22

23 2-2 HDD Cage Removal and Installation Figure 26 HDD cage removal 1. Loosen the two screws of the chassis base as shown. 2. Pull the HDD cage toward the front panel until it unlocks. 3. Remove the HDD cage vertically. Figure 27 HDD cage installation 1. Align the guide pins of the HDD cage with the grooves on the chassis base as shown. 2. Push HDD cage backward the front panel until it locks. 3. Secure HDD cage with 2 screws as shown. NOTE: All cage SKUs follow the same removal and installation guidelines. / Installation 23

24 2-3 Hot-swap HDD Assembly Removal and Installation Figure hot-swap HDD assembly removal 1. Press the tray button, and release the latch as shown. 2. Pull out the HDD assembly away from the drive bay. Figure hot-swap HDD assembly installation 1. With the open latch, insert the HDD assembly into the drive bay until the end of the HDD cage. 2.Push the latch when it is secured with a click. / Installation 24

25 Figure HDD removal 1. Bottom up the HDD tray, and face the wider side of HDD tray as shown. 2. Press your 2 thumbs on the HDD as shown NOTE: Please operate this on a stable surface in case the HDD dropping unexpectedly. 3. Lift the narrower side with your other fingers and release the HDD. Figure HDD installation 1. Slide in the HDD until align the anchor point of HDD tray. 2. Push down the HDD when it is secured with a click. / Installation 25

26 Figure " hot-swap HDD assembly removal 1. Press the tray button, and release the latch as shown. 2. Pull out the HDD assembly away from drive bay. Figure Hot-swap HDD assembly installation 1. With the open latch, insert the HDD assembly into the drive bay until the end of the HDD cage. 2. Push the latch when it is secured with a click. / Installation 26

27 Figure HDD removal 1. Bottom up the HDD tray, and face the non-concave side of HDD tray as shown. 2. Press your 2 thumbs on the HDD as shown. NOTE: Please operate this on a stable surface in case the HDD dropping unexpectedly 3. Lift the concave side with your other fingers and release the HDD. Figure HDD installation 1. Slide in the HDD until align the anchor point of HDD tray. 2. Push down the HDD when it is secured with a click. NOTE: To ensure proper system airflow requirements, all front drive bays are suggested to populate with a 3.5" drive tray in where it is supposed to be installed with a 3.5 drive, a 2.5 drive with plastic dummy filler or only dummy filler. In addition, in order to support a 2.5 drive in a 3.5 tray, a screw-type tray is required. / Installation 27

28 Figure HDD removal in 3.5 tray 1. Loosen 3 screws as shown. 2. Remove the HDD. Figure HDD installation in 3.5 tray 1. Install the HDD in the position on the tray. 2. Secure 3 screws as shown. / Installation 28

29 2-4 Internal 2.5 HDD Removal and Installation Figure 38 Internal 2.5'' HDD removal (RM23808) 1. Lift the plastic bracket tab to release 2.5 HDD assembly as shown. 2. Remove it from the HDD cage. 3. Detach the plastic bracket from 2.5 HDD. Figure 39 Internal 2.5'' HDD installation (RM23808) 1. Attach the plastic bracket with 2.5 HDD by engaging 4 pins with the dimples on one side of HDD. 2. Align the 2 dimples of the other side of HDD with the 2 hooks on the HDD cage as shown. 3. Push down the side with plastic bracket of 2.5 HDD assembly until it is secured with a click. / Installation 29

30 2-5 Internal Slim ODD Removal and Installation Figure 40 Internal slim ODD removal (RM23808) 1. Press the latch to release the ODD assembly. 2. Pull it out. 3. Loosen the 2 screws to detach the plastic bracket. Figure 41 Internal slim ODD installation (RM23808) 1. Secure the plastic bracket onto the slim ODD with 2 screws. 2. Insert the slim ODD assembly into the drive bay and push it until is secured with a click. / Installation 30

31 2-6 System Maintenance Figure 42 Removal of whole system from the rack 1. Open the latches and loosen the screws inside the latches as shown. 2. Firmly grab the rack handle on both sides. 3. Pull out the system from the rack with 2 hands. Figure 43 Installation of whole system into the rack 1. Firmly hold the system on both sides with 2 hands. 2. Align the slide rail of it with the slide rail on the rack. 3. Push the system until it secures, and tighten the screws in the latches on both sides. / Installation 31

32 2-7 Fan Assembly Removal and Installation Figure 44 Fan assembly removal 1. Loosen the thumb screws on both sides of the fan assembly. 2. Disconnect all the fan connectors. 3. Remove the fan assembly from the chassis base. Figure 45 Fan assembly installation 1. Install the fan assembly in place by aligning thumb screws with the screw holes on the chassis base. 2. Secure the thumb screws until it is fixed. 3. Connect the related fan connectors. / Installation 32

33 Figure 46 Fan module removal 1.Press the latch and remove the fan module from the bay of fan cage vertically. Figure 47 Fan module installation 1. Insert the fan module into the bay of fan cage until it is secured with a click. NOTE: All the fan modules are inserted with the same direction as the fan cage indicates. / Installation 33

34 Figure 48 Air baffle removal 1. Pull out the air baffle from the bay of fan cage. Figure 49 Air baffle installation 1. Insert the air baffle into the bay of fan cage until it locks. / Installation 34

35 2-8 2 x 2.5 Hot-swap Drive Cage Installation (Back Panel) Figure 50 2 x 2.5'' drive cage bracket installation (back panel) 1. Ensure the alignment of screw holes between the drive cage bracket and chassis base as shown. 2. Tighten the bracket with 2 screws. NOTE: Screw direction must be from outside of chassis to inside Figure 51 2 x 2.5'' drive cage installation (back panel) 1. Ensure the alignment of 1 screw hole between the cage and the bracket, and the other 1 between the cage and the backplane. 2. Secure the cage to the back panel with 1 screw. 3. Tighten the thumb screw on the cage to the bracket until it is fixed. / Installation 35

36 Figure 52 2 x 2.5 drive cage backplane installation (back panel) 1. Attach the backplane to the rear of 2.5 HDD cage. 2. Lock the backplane with the cage by sliding it as shown. 3. Tighten the backplane with 1 screw until it is fixed. / Installation 36

37 2-9 Full Height PCI-e Card Installation Figure 53 Full height back panel bracket 1. Replace the low profile back panel bracket with the full height one. 2. Secure the bracket with 2 screws. Figure 54 Riser card and bracket installation 3. Align 3 screw holes of the riser card with T nails on the bracket, and slide the riser card until it is secured with a click. 4. Tighten the riser card with 1 screw as shown. 5. Align 2 screw holes of PCIe slot bracket with the PCIe card as shown, and secure them with screws. 6. Insert the PCIe card into the slot on the riser card. 7. Secure the PCIe slot bracket and the riser card bracket with 1 screw. / Installation 37

38 2-10 PSU Installation Figure 55 Single 2U PSU installation 1. Install the PSU and ensure the alignment of PSU screws holes with the ones on chassis base and back panel matched. 2. Secure the PSU with 3 screws to the back panel. 3. Secure the PSU with 2 screws to the chassis base. / Installation 38

39 Figure 56 Redundant PSU cage assembly 1. Attach the PSU side bracket to the PSU cage, and secure it with 2 screws from the inside of PSU cage as shown. 2. Attach the PSU front bracket to the PSU cage, and secure it with 2 screws. 3. Install the PSU cage into the chassis and ensure the alignment of screw holes and bracket matched. Figure 57 Redundant PSU cage installation 4. Secure the PSU cage to the chassis base and the back panel with 4 screws. 5. Secure the PSU cage front bracket to the chassis base with 2 screws. / Installation 39

40 Figure 58 CRPS module installation 1. Insert CRPS module into the PSU cage and push until it is secured with a click. Figure 59 CRPS module removal 1. Press the latch without release as shown. 2. Pull the module handle to remove it from the PSU cage. / Installation 40

41 2-11 Slide Rail Installation Figure 60 Slide rail installation-1 ( B0) 1. Attach the inner rail to the chassis base while align T pins on the side of the system with the slots on the inner rail. Figure 61 Slide rail installation-2 ( B0) 2. Engage T pins with the slots on the inner rail. / Installation 41

42 Figure 62 Slide rail Installation-3 ( B0) 3. Lift the latch as shown. 4. Secure the inner rail with 1 screw. Figure 63 Slide rail Installation-4 ( B0) 5. Install the system into the rack with 2 persons. / Installation 42

43 3. Backplane Each drive tray includes separate LED indicators for drive activity and drive status. Light pipes integrated into the drive tray direct light emitted from LEDs mounted next to each drive connector on the backplane to the drive tray faceplate, making them visible from the front of the system Figure 64 Drive tray LED identification Table 7 Drive power LED/activity LED behavior LED ICON LED Color Behavior Condition A,C Power LED N/A Stay off Fault Blue Solid on Present B,D Activity LED Green Solid on Access Red Solid on Failure 1Hz blink Rebuild 4Hz blink Locate NOTE: The drive activity LED is driven by signals coming from the drive itself. Drive vendors may choose to operate the activity LED different from what is described in the table above. Should the activity LED on a given drive type behave differently than what is described, customers should take the drive vendor specifications as a reference for the specific drive model to determine what the expected drive activity LED operation should be. / Backplane 43

44 3-1 Storage Backplane Options RM238 series supports below backplane. 8 x 3.5 Mini-SAS HD passive backplane 12 x 3.5 Mini-SAS HD passive backplane 12 x 3.5 Mini-SAS HD active backplane 2 x 2.5 SATA/SAS backplane 2 x 2.5 NVMe passive backplane 8 x 2.5 Mini-SAS HD passive backplane 16 x 2.5 Mini-SAS HD passive backplane with docked expander board 8 x 2.5 Mini-SAS HD passive backplane with 4 x tri-mode (SATA/SAS/NVMe) backplane 8x 2.5 NVMe passive backplane All available SATA/SAS backplanes include the following common features: 12Gb/s SAS and 6Gbps SATA 29-pin SFF Gb/s rated drive interface connectors, providing both power and I/O signals to attached devices Hot swap support for SATA/SAS devices I2C interface from a 4-pin connector for device status communication to the BMC over SMBus LEDs to indicate drive activity and status for each attached device / Backplane 44

45 Port 12Gb/s SAS Passive Backplane Table Port SATA/SAS passive backplane Specification Host Interface HDD Interface Hot-Swap Display Environment Monitor Connectors Dimension Material Mini-SAS HD SFF-8680 Yes, allows user to replace device on line LED indicates storage device status Power LED Off (Fault) Blue on (Present) Activity LED Green on(access) Red on (Failure) Red 1Hz blink (Rebuild) Red 4Hz blink (Locate) Temperature sensor TMP75 (U3) 1. 8 x SFF x Mini-SAS HD 3. 1 x 8-pin ATX Mini-Fit power connector for +12V only 4. 4 x 4-pin fan connectors 5. 1 x 4-pin I2C connector 6. 1 x 1-pin SMD switch 432.0(L) x 53.2(W) x 2.4(H) mm FR4 4 layers Figure Port SATA/SAS passive backplane device side A. HDD_0 B. HDD_1 C. HDD_2 D. HDD_3 E. HDD_4 F. HDD_5 G. HDD_6 H. HDD_7 / Backplane 45

46 Figure Port SATA/SAS passive backplane host side Table 9 Connector description for port SATA/SAS passive backplane Label Connector Description Drawing A Power The backplane includes one power connector supplying 12V input to the backplane. Power is routed to the backplane via a power cable harness from the power supply. B Mini-SAS HD The backplane includes two multi-ports Mini-SAS HD connectors providing data signals for eight SAS/SATA drives on the backplane. A cable can be routed from matching connectors on the server board or add-in SATA/SAS HBA cards. C I2C The backplane includes one 4-pin connector used as a management interface to the server board. D Fan The backplane includes four fan connectors used to control and monitor fan speeds. E DIP switch Set the DIP switch to ON for RM23808 F CN3 (Mute pin) Fan setting for RM23808 G JC1 (JCK pin) Fan setting for RM23808 / Backplane 46

47 Table 10 Fan Setting for RM23808 DIP NC3(Mute pin) JA1(JCK pins) Fan ON PIN 5,6 OPEN PIN 4,6 SHORT 4 ON PIN 5,6 OPEN PIN 2,4 SHORT 2 ON PIN 5,6 SHORT N/A (No matter what status) 3 / Backplane 47

48 Port 12Gb/s SAS Passive Backplane Table Port SATA/SAS passive backplane Specification Host Interface Device Interface Hot-Swap Display Environment Monitor Connectors Dimension Material Mini-SAS HD SFF-8680 Yes, allows user to replace storage device on line LED indicates storage device status Power LED Off (Fault) Blue on (Present) Activity LED Green on(access) Red on (Failure) Red 1Hz blink (Rebuild) Red 4Hz blink (Locate) Temperature sensor TMP75 (U04,U05) x SFF x Mini-SAS HD 3. 2 x 8-pin ATX Mini-Fit power connectors for +12V only 4. 4 x 4-pin fan connectors 5. 1 x 4-pin I2C connector 6. 1 x 8-pin SMD switch 432.0(L) x 81.0(W) x 2.4(H) mm FR4 6 layers Figure Port SATA/SAS passive backplane device side A. HDD_0 B. HDD_1 C. HDD_2 D. HDD_3 E. HDD_4 F. HDD_5 G. HDD_6 H. HDD_7 I. HDD_8 J. HDD_9 K. HDD_10 L. HDD_11 / Backplane 48

49 Figure Port SATA/SAS passive backplane host side Table 12 Connector description for port SATA/SAS passive backplane Label Description Description Drawing A Power The backplane includes two power connectors supplying 12V input to the backplane. Power is routed to the backplane via a power cable harness from the power supply. B Mini-SAS HD The backplane includes three multi-ports Mini-SAS HD connectors providing data signals for twelve SATA/SAS drives on the backplane. A cable can be routed from matching connectors on the server board or add-in SATA/SAS HBA cards. C I2C The backplane includes one 4-pin connector used as a management interface to the server board. D Fan The backplane includes four fan connectors used to control and monitor fan speeds. E DIP switch Follow below dip switch setting / Backplane 49

50 Table 13 Dip Switch Setting PIN-Number PIN-Definition ON OFF 1 Fan 1 EN DISABLE 2 Fan 2 EN DISABLE 3 Fan 3 EN DISABLE 4 Fan 4 EN DISABLE 5 MB PWM EN DISABLE 6 Temperature Alarm ACC Mode SGPIO HDD 8 Buzzer Alarm EN DISABLE / Backplane 50

51 Port 12Gb/s SASActive Backplane Table Port SATA/SAS active backplane Specification Host Interface Device Interface Hot-Swap Display Environment Monitor Connectors Dimension Material Mini-SAS HD SFF-8680 Yes, allows user to replace storage device on line LED indicates storage device status Power LED Off (Fault) Blue on (Present) Activity LED Green on(access) Red on (Failure) Red 1Hz blink (Rebuild) Red 4Hz blink (Locate) Temperature sensor TMP75 (U7,U8) x SFF x Mini-SAS HD 3. 2 x 8-pin ATX Mini-Fit power connectors for +12V only 4. 4 x 4-pin fan connectors 5. 1 x 4-pin I2C connector 6. 1 x 8-pin SMD switch 432.0(L) x 81.0(W) x 2.4(H) mm FR4 8 layers Figure 69 12G Mini SAS HD Port Active Backplane front view A. HDD_0 B. HDD_1 C. HDD_2 D. HDD_3 E. HDD_4 F. HDD_5 G. HDD_6 H. HDD_7 I. HDD_8 J. HDD_9 K. HDD_10 L. HDD_11 / Backplane 51

52 Figure Port SATA/SAS active backplane host side Table 15 Connector description for port SATA/SAS active backplane Label Description Description Drawing A Power The backplane includes two power connectors supplying 12V input to the backplane. Power is routed to the backplane via a power cable harness from the power supply. B Mini-SAS HD The backplane includes two multi-ports Mini-SAS HD connectors providing data signals for twelve SATA/SAS drives on the backplane. A cable can be routed from matching connectors on the add-in SATA/SAS HBA cards. C I2C The backplane includes one 4-pin connector used as a management interface to the server board. D Fan The backplane includes four fan connectors used to control and monitor fan speeds. E DIP switch Follow below dip switch setting F JC5 Fan setting for RM23812 active BP / Backplane 52

53 Table 16 Dip Switch Setting PIN-Number PIN-Definition ON OFF 1 System Fan Quantity PWM EN DISABLE 3 Temperature Alarm System Fan EN DISABLE 5 Buzzer EN DISABLE 6 SES MON EN DISABLE 7/8 I2C Address SET SET Table 17 Fan Setting for RM23812 DIP JC5 Fan DIP 4 ON,DIP 1 OFF PIN 5,6 OPEN 4 DIP 4 ON,DIP 1 ON PIN 5,6 OPEN 2 DIP 4 ON PIN 5,6 SHORT 3 / Backplane 53

54 3-5 2 x 2.5 Drive Bay Accessory Kit Chenbro Accessory Kit Product Code: 83H for SATA/SAS module and A0 for NVMe module. The 2U product family provides the option to support 2 x 6 Gbps SATA SSDs or 2 x PCIe NVMe SSDs installed to a drive module mounted in the back of the system. Figure '' 2-bay drive module Table 18 Solution and operating condition for bay drive module Drive type Application Drive thickness Drive quantity Air duct System ambient temperature SATA SSD OS/Cache 7mm 2 X mm 2 X 35 3 NVMe SSD Cache 7mm 2 V mm 1 V 35 4 System fan required NOTE : 1. 2-port drive module is designed for OS and cache applications in which 7mm/9.5mm SATA SSD or 7mm/15mm NVMe are suggested. 2. For these configurations, stressed program is set as 100% random write which generates the most heat as the worst scenario. Solutions above are suggested for better thermal performance under this stressed condition. 3. Disk/flash drive behavior in OS/cache application is similar to mix random read/write which may allow users to adopt 2x 15mm NVMe. Physical test is suggested to evaluate the operating condition. The backplane includes several connectors and a jumper block, as defined in the following illustrations. / Backplane 54

55 Table Port SATA/SAS passive backplane Specification Host Interface Device Interface Hot-Swap Display Environment Monitor Connectors Dimension Material SATA 7-pin SFF-8680 Yes, allows user to replace storage device on line LED indicates storage device status Power LED Off (Fault) Blue on (Present) Activity LED Green on(access) Red on (Failure) Red 1Hz blink (Rebuild) Red 4Hz blink (Locate) Temperature sensor TMP75 (U2) 1. 2 x SFF x SATA 7-pin connector 3. 1 x 4-pin ATX Mini-Fit power connector for +5V and +12V 4. 1 x 4-pin I2C connector 77.0(L) x 38.7(W) x 2.4(H) mm FR4 4 layers Figure '' 2-Port SATA/SAS passive backplane device side A. HDD0 B. HDD1 / Backplane 55

56 Figure '' 2-port SATA/SAS passive backplane host side Table 20 Connector description for port SATA/SAS passive backplane Label Connector Description Picture A Power The backplane includes one power connector supplying 5V/12V input to the backplane. Power is routed to the backplane via a power cable harness from the power supply. B SATA 7-pin The backplane includes two SATA 7-pin connectors providing data signals for two SATA/SAS drives on the backplane. A cable can be routed from matching connectors on the server board or add-in SATA/SAS HBA cards. C I2C The backplane includes one 4-pin connector used as a management interface to the server board. / Backplane 56

57 Table Port NVMe passive backplane Specification Host Interface Device Interface Hot-Swap Display Environment Monitor Connectors Dimension Material OCuLink SFF-8639 (U.2) Yes, allows user to replace storage device on line LED indicates storage device status Power LED Off (Fault) Blue on (Present) Activity LED Green on(access) Red on (Failure) Red 1Hz blink (Rebuild) Red 4Hz blink (Locate) Temperature sensor TMP75 (U1) 1. 2 x SFF-8639 (U.2) 2. 2 x OCuLink 3. 1 x 4-pin ATX Mini-Fit power connector for +12V only 4. I x 4-pin I2C connector 77.0(L) x 34.0(W) x 2.4(H) mm FR4 6 layers Figure '' 2-Port NVMe passive backplane device side A. HDD0 B. HDD1 / Backplane 57

58 Figure '' 2-port NVMe passive backplane host side Table 22 Connector description for port NVMe passive backplane Label Connector Description Picture A Power The backplane includes one power connector supplying 12V input to the backplane. Power is routed to the backplane via a power cable harness from the power supply. B OCuLink The backplane includes two OCuLink connectors providing data signals for two NVMe drives on the backplane. A cable can be routed from matching connectors on the server board or add-in switch cards. C I2C The backplane includes one 4-pin connector used as a management interface to the server board. / Backplane 58

59 Port 12Gb/s SAS Passive Backplane Table Port SATA/SAS passive backplane Specification Host Interface Device Interface Hot-Swap Display Environment Monitor Connectors Dimension Material Mini-SAS HD SFF-8680 Yes, allows user to replace storage device on line LED indicates storage device status Power LED Off (Fault) Blue on (Present) Activity LED Green on(access) Red on (Failure) Red 1Hz blink (Rebuild) Red 4Hz blink (Locate) Temperature sensor TMP75 (U3) 1. 8 x SFF x Mini-SAS HD 3. 1 x 8-pin ATX Mini-Fit power connector for +12V only 4. 4 x 4-pin fan connectors 5. 2 x 4-pin I2C connectors 6. 1 x 6-pin SMD switch 142.0(L) x 580(W) x 2.4(H) mm FR4 8 layers Figure Port SATA/SAS passive backplane device side A. HDD_0 B. HDD_1 C. HDD_2 D. HDD_3 E. HDD_4 F. HDD_5 G. HDD_6 H. HDD_7 / Backplane 59

60 Figure Port SATA/SAS passive backplane host side Table 24 Connector description for port SATA/SAS passive backplane Label Connector Description Picture A Power The backplane includes one power connector supplying 12V input to the backplane. Power is routed to the backplane via a power cable harness from the power supply. B Mini-SAS HD The backplane includes two multi-ports Mini-SAS HD connectors providing data signals for eight SATA/SAS drives on the backplane. A cable can be routed from matching connectors on the server board or add-in SATA/SAS HBA cards. C I2C The backplane includes two 4-pin connectors. One is used as a management interface to the server board and the other is for BP to BP communication. D Fan The backplane includes four FAN connectors used to control and monitor fan speeds. E DIP switch Follow below dip switch setting Table 25 Dip Switch Setting PIN-Number PIN-Definition ON OFF 1 Board ID 0 EN DISABLE 2 Board ID 1 EN DISABLE 3 System Fan EN DISABLE 4 Buzzer Alarm EN DISABLE 5 Temperature Alarm ACC Mode HDD SGPIO / Backplane 60

61 Port 12Gb/sSAS Passive Backplane Docked with Expander board Host Interface Device Interface Hot-Swap Display Table Port SATA/SAS Passive Backplane Docking to expander board SFF-8680 Specification Yes, allows user to replace storage device on line LED indicates storage device status Power LED Off (Fault) Blue on (Present) Activity LED Green on(access) Red on (Failure) Red 1Hz blink (Rebuild) Red 4Hz blink (Locate) Environment Monitor Temperature sensor TMP75 (U1, U4, U10, U11) Connectors Dimension Material x SFF x 8-pin ATX Mini-Fit power connectors for +12V only 3. 1 x 4-pin I2C connector 286.0(L) x 80.0(W) x 2.4(H) mm FR4 8 layers Figure Port SATA/SAS passive backplane device side A. HDD_0 B. HDD_1 C. HDD_2 D. HDD_3 E. HDD_4 F. HDD_5 G. HDD_6 H. HDD_7 I. HDD_8 J. HDD_9 K. HDD_10 L. HDD_11 M. HDD_12 N. HDD_13 O. HDD_14 P. HDD_15 / Backplane 61

62 Figure Port SATA/SAS passive backplane host side Table 27 Connector description for port SATA/SAS passive backplane Label Connector Description Picture A Power The backplane includes two power connectors supplying 12V input to the backplane. Power is routed to the backplane via a power cable harness from the power supply. B I2C The backplane includes one 4-pin connector used as a management interface to the server board. / Backplane 62

63 Table 28 12Gb/s expander board Specification Host Interface Device Interface Hot-Swap Environment Monitor Connectors Dimension Material SFF-8680 Mini-SAS HD (to 8-port BP)/Board docking (to 16-port BP) Yes, allows user to replace storage device on line Temperature sensor TMP75 (U3) 1. 5 x Mini-SAS HD 2. 1 x 8-pin ATX Mini-Fit power connector for +12V only 3. 5 x 4-pin fan connectors 4. 2 x 4-pin I2C connectors 5. 1 x 8-pin SMD switch 250.0(L) x 67.8(W) x 1.6(H) mm FR4 8 layers Figure 80 Expander board back view / Backplane 63

64 Figure 81 Expander board front view Table 29 Connector description for expander board Label Connector Description Picture A Power The backplane includes one power connector supplying 12V input to the backplane. Power is routed to the backplane via a power cable harness from the power supply. B Mini-SAS HD The expander board includes five multi-ports Mini-SAS HD connectors which two are connected to 8-port BP and three are connected to M/B. A cable can be routed from matching connectors on the add-in SATA/SAS HBA cards. C I2C The backplane includes two 4-pin connectors used as a management interface to the server board. D Fan The expander board includes five fan connectors used to control and monitor fan speeds. E DIP switch Follow below dip switch setting Table 30 Dip Switch Setting PIN-Number PIN-Definition ON OFF 1 System Fan Quantity Smart Fan EN DISABLE 3 Temperature Alarm Fan Alarm EN DISABLE 5 Buzzer EN DISABLE 6 SES Monitor EN Page 0x08 only 7 I2C Address C0 C2 8 BP SKU Tri mode BP 16-port BP only / Backplane 64

65 Port SATA/SAS/NVMe (4 x Tri-mode) Passive Backplane Table " 8-port SATA/SAS/NVMe (4 x Tri-mode) passive backplane Specification Host Interface Device Interface Hot-Swap Display Environment Monitor Connectors Dimension Material Mini-SAS HD/OCuLink SFF-8639 Yes, allows user to replace storage device on line LED indicates storage device status Power LED Off (Fault) Blue on (Present) Activity LED Green on(access) Red on (Failure) Red 1Hz blink (Rebuild) Red 4Hz blink (Locate) Temperature sensor TMP75 (U02) 1. 8 x SFF x OCuLink 3. 2 x Mini-SAS HD 4. 1 x 8-pin ATX Mini-Fit Power connector for +12V only 142.0(L) x 80.0(W) x 2.4(H) mm FR4 8 layers Figure '' 8-port SATA/SAS/NVMe Backplane front view A. HDD_0 B. HDD_1 C. HDD_2 D. HDD_3 E. HDD_4 F. HDD_5 G. HDD_6 H. HDD_7 / Backplane 65

66 Figure '' 8-port SATA/SAS/NVMe passive backplane host side Table 32 Connector description for port SATA/SAS/NVMe passive backplane Label Connector Description Picture A Power The backplane includes one 2 x 4 connector supplying 12V power to the backplane. Power is routed to the backplane via a power cable harness from the power supply. B Mini-SAS HD The backplane includes two multi-ports Mini-SAS HD connectors providing data signals for eight SATA/SAS drives on the backplane. A cable can be routed from matching connectors on the server board or add-in SATA/SAS HBA cards. C OCuLink The backplane includes four OCuLink connectors providing data signals for four NVMe drives on the backplane. A cable can be routed from matching connectors on the server board or add-in switch cards. D I2C The backplane includes two 4-pin connectors. One is used for LED signal transmission and the other is for thermal sensor monitoring to MB.

67 Port PCIe Gen3NVMe Passive Backplane Table Port NVMe passive backplane Specification Host Interface Device Interface Hot-Swap Display Environment Monitor Connectors Dimension Material OCuLink SFF-8639 Yes, allows user to replace storage device on line LED indicates storage device status Power LED Off (Fault) Blue on (Present) Activity LED Green on(access) Red on (Failure) Red 1Hz blink (Rebuild) Red 4Hz blink (Locate) Temperature sensor TMP75 (U02) 1. 8 x SFF x OCuLink 3. 1 x 8-pin ATX Mini-Fit power connector for +12V only 5. 2 x I2C connectors 142.0(L) x80.0(w) x 2.4(H) mm FR4 8 layers Figure '' 8-port NVMe passive backplane device side A. HDD_0 B. HDD_1 C. HDD_2 D. HDD_3 E. HDD_4 F. HDD_5 G. HDD_6 H. HDD_7 / Backplane 67

68 Figure '' 8-port NVMe passive backplane host side Table 34 Connector description for port NVMe passive backplane Label Connector Description Picture A Power The backplane includes one 2 x 4 connector supplying 12V power to the backplane. Power is routed to the backplane via a power cable harness from the power supply. B OCuLink The backplane includes eight OCuLink connectors providing data signals for eight NVMe drives on the backplane. A cable can be routed from matching connectors on the server board or add-in switch cards. C I2C The backplane includes two 4-pin connectors. One is used as a management interface to the server board and the other is for BP to BP communication. / Backplane 68

69 4. Maintenance and Service DOA (Dead on Arrival) If the products are found Defect On Arrival, please contact Chenbro s regional sales or regional CQE and indicate the defective status via along with product photos, description. You may need to return the damaged item by request. The customer should ensure that the products are Defect On Arrival within three months from CHENBRO shipping date and the damages are not caused by shipping or failures resulting from accident, misuse, abuse, neglect, mishandling, misapplication, modification, improper operation, improper repair or rework. CHENBRO are not responsible for the cost of replacement including the delivery cost. CHENBRO also reserves the right to examine the DOA products. If the damages of DOA products are caused by improper action as described above, the customer shall be liable for paying the related charge having occurred or paying the price of the replacements if the DOA products are totally discarded. Apply a RMA number Return the product for repairing Receive Service charges notice Receive the repaired product TECHNICAL SUPPORT Please provide following information when you apply technical support: Product model name and/or part number Product serial number and bar code Buzzer beeping pattern and/or failure LED flashing pattern Detailed, specific questions You may also contact Chenbro s regional technical support as below- Website: CENBRO MICOM CO., LTD. fae@chenbro.com Tel: Fax: CHENBRO MICOM (USA) INC. usfae@chenbro.com Tel: Fax: Chenbro Europe B.V. defae@chenbro.com Tel: Fax: / Maintenance and Service 69

Chenbro. ES34169 Chassis User s Manual. April / 2 /

Chenbro. ES34169 Chassis User s Manual. April / 2 / Chenbro ES34169 Chassis User Manual April / 2 / 2010 www.chenbro.com 1 Copyright Copyright 2007 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual are

More information

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H User s Manual. Version A0. July / 28 / 2008

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H User s Manual. Version A0. July / 28 / 2008 CHENBRO Storage Chassis 4-Port Backplane 80H103215-013 Version A0 July / 28 / 2008 1 Copyright Copyright 2006 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in

More information

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H C0. User s Manual. September / 10 / 2009

CHENBRO. Storage Chassis 4-Port Mini-SAS Backplane 80H C0. User s Manual. September / 10 / 2009 CHENBRO Storage Chassis 4-Port Backplane 80H10321513C0 September / 10 / 2009 1 Copyright Copyright 2006 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual

More information

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E

Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E Serial ATA Hot Swap Drive Cage Upgrade Kit for: Intel Server Chassis SC5200 Intel Server Chassis SC5250-E A Guide for Technically Qualified Assemblers of Intel Identified Subassemblies/Products Order Number:

More information

Intel Storage System JBOD2000S3

Intel Storage System JBOD2000S3 Intel Storage System JBOD2000S3 Product Family Configuration Guide A reference document used to assist customers in ordering parts and accessories available to configure the Intel Storage System JBOD2000S3

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

CHENBRO. 4-Port SAS / SATA-II Backplane 80H User s Manual. Version 1.1~1.3. July / 18 / 2008

CHENBRO. 4-Port SAS / SATA-II Backplane 80H User s Manual. Version 1.1~1.3. July / 18 / 2008 CHENBRO 4-Port SAS / SATA-II Backplane 80H102209-010 Version 1.1~1.3 July / 18 / 2008 1 Copyright Copyright 2006 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials

More information

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

64 Bays SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0 64 Bays SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Preface... 4 Before You Begin... 5 Safety Guidelines... 5 Controller Configurations... 5 Packaging, Shipment and Delivery... 5 Unpacking

More information

19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness

19 Rackmount Cases A3211. Enrich Your Product Line and Build Your Brand Awareness 19 Rackmount Cases A3211 Enrich Your Product Line and Build Your Brand Awareness 0303-00283 USER S MANUAL Table of Contents 1. Introduction. 1 2. Standard parts. 2 2-1 Disassembly of the Top Cover...2

More information

Oracle <Insert Picture Here>

Oracle <Insert Picture Here> Slide 1 Oracle Slide 2 WZT-6509 version B Sun Fire Nehalem and Westmere Rack-Mount Server Installation and Replacement Welcome to the installation and replacement

More information

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems.

DNS User Manual. Version Dec DataON Storage, storage division of Area Data Systems. DNS-2670 User Manual Version Dec. 2015 DataON Storage, storage division of Area Data Systems. Contents 1 Introduction... 1 1.1 System Overview... 3 1.1.1 System Top View...3 1.1.2 Front View...4 1.1.3

More information

Chenbro RB14604/08 Spares/Accessories List and Configuration Guide

Chenbro RB14604/08 Spares/Accessories List and Configuration Guide Chenbro RB4604/08 Spares/Accessories List and Configuration Guide A reference guide to assist customers in ordering the necessary components to configure the Chenbro RB4604/08 Revision.0 June 207 REVISION

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

Chenbro RM238 Series Spares/Accessories List and Configuration Guide

Chenbro RM238 Series Spares/Accessories List and Configuration Guide Chenbro RM238 Series Spares/Accessories List and Configuration Guide A reference guide to assist customers in ordering the necessary components to configure the Chenbro RM238 series Revision. December

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2 SAS to SAS/SATA JBOD Subsystem Revision 1.2 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Subsystem... 6 1.4 Identifying Parts

More information

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting

MIC-3001/8. 3U/4U CompactPCI. Enclosure for Rackmounting MIC-3001/8 3U/4U CompactPCI Enclosure for Rackmounting Copyright Notice This document is copyrighted, 1999. All rights are reserved. The original manufacturer reserves the right to make improvements to

More information

Chassis (FRU) Replacement Guide

Chassis (FRU) Replacement Guide SIEM9750 Release 1.0 Chassis (FRU) Replacement Guide Issue: 02 Date: 2011-11-07 Page 1 of 26 This document is intended for Symantec support personnel, IBM, or other authorized Symantec Service Partners.

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0 SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Terminologies... 6 Chapter 2 Getting Started... 7 2.1 Unpacking

More information

CHENBRO. 6-Port 3Gb/s Mini-SAS Backplane 80H A0. User s Manual. August / 2010

CHENBRO. 6-Port 3Gb/s Mini-SAS Backplane 80H A0. User s Manual. August / 2010 CHENBRO 6-Port 3Gb/s Mini-SAS Backplane 80H10321709A0 August / 2010 1 Copyright Copyright 2010 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual are

More information

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options

Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options CHAPTER 4 Installing the Cisco ADE 2130 and 2140 Series Appliance Hardware Options This chapter provides instructions for installing, replacing, and removing various hardware options in your Cisco ADE

More information

RM414 User s Manual. Preliminary Release

RM414 User s Manual. Preliminary Release Preliminary Release Copyright This document is copyrighted, 2003, by Chenbro Micom Co., Ltd. All rights are reserved. Chenbro Micom Co., Ltd. reserves the right to make improvements to the products described

More information

CHENBRO. SR30169 Server Chassis 4-Port 6Gb/s SAS/SATA Backplane. User s Manual 80H A0. Revision: 1.1. Dec / 3 / 2013

CHENBRO. SR30169 Server Chassis 4-Port 6Gb/s SAS/SATA Backplane. User s Manual 80H A0. Revision: 1.1. Dec / 3 / 2013 CHENBRO SR30169 Server Chassis 4-Port 6Gb/s SAS/SATA Backplane User s Manual 80H10230101A0 Revision: 1.1 Dec / 3 / 2013 1 Copyright Copyright 2010 Chenbro Micom Co., Ltd. All rights reserved. Unless otherwise

More information

Dell PowerVault MD3060e Storage Enclosure Owner's Manual

Dell PowerVault MD3060e Storage Enclosure Owner's Manual Dell PowerVault MD3060e Storage Enclosure Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you

More information

HP ProLiant DL165 G7 Server

HP ProLiant DL165 G7 Server HP ProLiant DL165 G7 Server Installation Instructions Part Number 601464-003 Identifying server components Front panel components Figure 1 Front Panel Components / 4 3.5 LFF HDD Item Description 1 Thumbscrews

More information

RSC-1R Rackmount Storage Chassis User's Manual

RSC-1R Rackmount Storage Chassis User's Manual RSC-1R Rackmount Storage Chassis User's Manual UM_RSC-1R_v.1_071216 CONTENTS PREFACE... i SAFETY INSTRUCTIONS... ii Chapter 1. Prodcut Introduction... 1 1.1 Box Content...1 1.2 Specifications...2 1.3 General

More information

HP ProLiant MicroServer

HP ProLiant MicroServer HP ProLiant MicroServer Installation Sheet Part Number 615715-004 Panel door components Item Component 1 16 screws for HDD installation 2 4 screws for ODD installation 3 Screw driver Rear panel components

More information

DNS-2608 Enterprise JBOD Enclosure User Manual

DNS-2608 Enterprise JBOD Enclosure User Manual DNS-2608 Enterprise JBOD Enclosure User Manual Nov.2017 Copyright DataON. All rights reserved. www.dataonstorage.com 1 Contents Package Contents... 3 System Requirements... 3 Technical Support... 3 DataON

More information

CHASSIS INSTALLATION GUIDE

CHASSIS INSTALLATION GUIDE SUPER SC942S-600 SC942i-600/550 SC942 CHASSIS INSTALLATION GUIDE 1.0 SUPER SC942 Chassis User's Guide Table of Contents Chapter I: Unpacking and Check Lists... 1-3 Chapter 2: Installation Procedures...

More information

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual

MIC-3001/8. 3U/4U CompactPCI Enclosure for Rack Mounting. User Manual MIC-3001/8 3U/4U CompactPCI Enclosure for Rack Mounting User Manual Copyright The documentation and the software included with this product are copyrighted 2004 by Advantech Co., Ltd. All rights are reserved.

More information

FWA-6280A User Manual 1. FWA-6280A User Manual

FWA-6280A User Manual 1. FWA-6280A User Manual 1 Copyright Notice This document is copyrighted, 2005. All rights are reserved. The original Manufacturer reserves the right to make improvements to the products described in this manual at any time without

More information

1.2 Intel Server Chassis SC5400BASE Summary

1.2 Intel Server Chassis SC5400BASE Summary Introduction Intel Server Chassis SC5400BASE Customization Panels Unpainted Rack Top Cover Slim Line CDROM/USB Floppy Kit Intel Server Chassis SC5400BRP 10-pack Branding / Customization Panels Unpainted

More information

CHENBRO. User s Manual port 6Gb/s SAS Expander Backplane 80H A0. Version A0

CHENBRO. User s Manual port 6Gb/s SAS Expander Backplane 80H A0. Version A0 - 1 - CHENBRO 3.5 24-port 6Gb/s SAS Expander Backplane 80H10341801A0 Version A0 May / 05 / 2011 - 2 - Copyright Copyright 2011 CHENBRO Micom Co., Ltd.. All rights reserved. Unless otherwise indicated,

More information

User manual. Gaming 978BG - Tank-Buster

User manual. Gaming 978BG - Tank-Buster User manual Gaming 978BG - Tank-Buster Content Chapter 1 Product introduction 1.1 Specification...03 1.2 Accessory...04 Chapter 2 Installation guide 2.1 Side panel assembly...05 2.2 Motherboard installation...06

More information

Dell SC5020 and SC5020F Storage Systems Getting Started Guide

Dell SC5020 and SC5020F Storage Systems Getting Started Guide Dell SC5020 and SC5020F Storage Systems Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

CSE-M14T Mobile Rack USER'S GUIDE

CSE-M14T Mobile Rack USER'S GUIDE SUPER CSE-M14T Mobile Rack USER'S GUIDE Rev. 1.0 CSE-M14T Mobile Rack User's Guide The information in this User s Guide has been carefully reviewed and is believed to be accurate. The vendor assumes no

More information

Dell MD1280 Storage Enclosure Getting Started Guide

Dell MD1280 Storage Enclosure Getting Started Guide Dell MD1280 Storage Enclosure Getting Started Guide Regulatory Model: SP-2584, E11J Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

RMC HS. User Manual. Version 1.0

RMC HS. User Manual. Version 1.0 RMC2108-670-HS User Manual Version 1.0 Content Manual Structure Foreword Chapter 1 Chassis Overview Chapter 2 Easy Installation Instruction Chapter 3 Chassis Parameters Foreword This manual is about the

More information

Intel IP Network Server NSI2U

Intel IP Network Server NSI2U Product Brief Intel IP Network Server NSI2U The Intel IP Network Server, an alternative to custom chassis for network security applications, raises the performance bar for IP network security products

More information

Dell SCv3000 and SCv3020 Storage System Getting Started Guide

Dell SCv3000 and SCv3020 Storage System Getting Started Guide Dell SCv3000 and SCv3020 Storage System Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make

More information

SAS JBOD Installation Reference Guide Revision 1.0

SAS JBOD Installation Reference Guide Revision 1.0 SAS JBOD 16-bay Rackmount Enclosure Installation Reference Guide Revision 1.0 P/N: PW0020000000281 Copyright No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

Wiwynn SV320 Maintenance User Manual

Wiwynn SV320 Maintenance User Manual Wiwynn SV30 Maintenance User Manual Version. Published Apr. 03 Copyright 0 Wiwynn. All rights reserved Content System Upgrades...5 Opening the Server...5 Removing the Top Cover... 5 Installing the Top

More information

CHENBRO. User s Manual SK to-1 SATA / SAS HDD Storage Kit. Version A2~A4. May / 26 / 2008

CHENBRO. User s Manual SK to-1 SATA / SAS HDD Storage Kit. Version A2~A4. May / 26 / 2008 CHENBRO SK31101 1-to-1 SATA / SAS HDD Storage Kit Version A2~A4 May / 26 / 2008 1 Copyright Copyright 2006 CHENBRO Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this

More information

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-8i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.2 DB15-000984-02 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

1U Device Expansion Unit Configuration Guide

1U Device Expansion Unit Configuration Guide 1U Device Expansion Unit Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper

More information

Xpander Rack Mount 16 5U Gen 3 with Redundant Power [Part # XPRMG3-1625URP] User Guide

Xpander Rack Mount 16 5U Gen 3 with Redundant Power [Part # XPRMG3-1625URP] User Guide Xpander Rack Mount 16 5U Gen 3 with Redundant Power [Part # XPRMG3-1625URP] User Guide Xpander Rack Mount 16 5U Gen 3 with Redundant Power (RP) supplies is a rack mount PCI Express (PCIe) expansion enclosure

More information

Dell EMC Storage MD1280 Enclosure Owner's Manual

Dell EMC Storage MD1280 Enclosure Owner's Manual Dell EMC Storage MD1280 Enclosure Owner's Manual Regulatory Model: SP-2584, E11J Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product.

More information

Customer Replacement Procedure

Customer Replacement Procedure Customer Replacement Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Replacing a faulted 80-drive DAE cooling module 302-003-777 REV 01 July 2017 This document describes how to replace

More information

80H A0 80H A0 80H A0

80H A0 80H A0 80H A0 CHENBRO 2.5 24-Port 6Gb/s SAS Expander Backplane 80H10341802A0 80H10341803A0 80H17341801A0 User s Manual Version A0 March / 31 / 2011 Copyright Copyright 2011 CHENBRO Micom Co., Ltd.. All rights reserved.

More information

Flexible General-Purpose Server Board in a Standard Form Factor

Flexible General-Purpose Server Board in a Standard Form Factor Product brief Small and Medium Business, Storage, Networking, Web Hosting, and Security Appliances Intel Server Board S2600ST Product Family Featuring the Intel Xeon Processor Scalable Family Flexible

More information

NAS System. User s Manual. Revision 1.0

NAS System. User s Manual. Revision 1.0 User s Manual Revision 1.0 Before You Begin efore going through with this manual, you should read and focus on the following safety guidelines. Information about the NAS system s packaging and delivery

More information

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual

Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Dell SCv300 and SCv320 Expansion Enclosure Owner's Manual Regulatory Model: E03J, E04J Regulatory Type: E03J001, E04J001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that

More information

3+1 U CPCI Serial System

3+1 U CPCI Serial System 3+ U CPCI Serial System User s Manual Product Number: 4579-46/47/48/49/40/4/4/43/44 Doc-No: 6397-349_R.0 January 06 R.0 January 06 Initial Release Impressum: Schroff GmbH Langenalber Str. 96-00 75334 Straubenhardt,

More information

MPP1700 User s Manual

MPP1700 User s Manual 2011 Visionary Solutions, Inc. All rights reserved. Please visit the support section of our website at www.vsicam.com for manuals, other documentation, and software downloads. Visionary Solutions, Inc.

More information

TRC-190 User s Manual

TRC-190 User s Manual User s Manual Edition 3.2, May 2017 www.moxa.com/product 2017 Moxa Inc. All rights reserved. User s Manual The software described in this manual is furnished under a license agreement and may be used only

More information

WMC-402M. Wallmount Chassis User Manual

WMC-402M. Wallmount Chassis User Manual WMC-402M Wallmount Chassis User Manual Copyright Notice This document and product is copyrighted, January 2014, by AICSYS, Inc. All rights are reserved. No part of this manual may be reproduced, copied,

More information

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-16i PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.1 DB15-001137-01 For a comprehensive list of changes to this document, see the Revision History.

More information

Dell SC460 Expansion Enclosure Getting Started Guide

Dell SC460 Expansion Enclosure Getting Started Guide Dell SC460 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:

More information

CHENBRO CK port SAS Expander Card User s Manual. Version B0. September / 01 / 2009

CHENBRO CK port SAS Expander Card User s Manual. Version B0. September / 01 / 2009 CHENBRO CK12803 28-port SAS Expander Card Version B0 September / 01 / 2009 1 Copyright Copyright 2008 CHENBRO Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual

More information

Dell SC5020 and SC5020F Storage System Owner s Manual

Dell SC5020 and SC5020F Storage System Owner s Manual Dell SC5020 and SC5020F Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

SGI InfiniteStorage 120

SGI InfiniteStorage 120 SGI InfiniteStorage 120 Mass Storage Hardware Topics Edition 003 007-4853-003 Proprietary Rights Notices COPYRIGHT 2006, 2007 SGI. All rights reserved; provided portions may be copyright in third parties,

More information

High Performance Computing

High Performance Computing 21 High Performance Computing High Performance Computing Systems 21-2 HPC-1420-ISSE Robust 1U Intel Quad Core Xeon Server with Innovative Cable-less Design 21-3 HPC-2820-ISSE 2U Intel Quad Core Xeon Server

More information

CHENBRO. 8-Port 6Gb/s SATA Backplane 80H A0. User s Manual. September / 2010

CHENBRO. 8-Port 6Gb/s SATA Backplane 80H A0. User s Manual. September / 2010 CHENBRO 8-Port 6Gb/s SATA Backplane 80H10313107A0 September / 2010 1 Copyright Copyright 2010 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this manual are

More information

Rocsecure NE52 NAS System

Rocsecure NE52 NAS System Rocsecure NE52 NAS System Revision 1.0 Table of Contents Preface... 3 Before You Begin... 4 Safety Guidelines... 4 Packaging, Shipment and Delivery... 4 Chapter 1 Introduction... 5 1.1 Key Features...

More information

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9207-4i4e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.1 DB15-000858-02 Revision History Version and Date Description of Changes Final Version 2.1, Updated

More information

SCv360 Expansion Enclosure

SCv360 Expansion Enclosure SCv360 Expansion Enclosure Getting Started Guide Regulatory Model: CYAE Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION:

More information

SCSI Cable Installation Instructions

SCSI Cable Installation Instructions Identifying the SCSI Cable Parts SCSI Cable Installation Instructions for HP ProLiant DL100 Series Generation 2 Servers Item Description 1 Connector end 2 240 mm location 3 Terminator end Read instructions

More information

CHENBRO. 24-Port 3.5 mini-sas Backplane with Expander 80H A0. User s Manual. December 2012

CHENBRO. 24-Port 3.5 mini-sas Backplane with Expander 80H A0. User s Manual. December 2012 CHENBRO 24-Port 3.5 mini-sas Backplane with Expander 80H10024001A0 December 2012 1 Copyright Copyright 2012 Chenbro Micom Co., Ltd.. All rights reserved. Unless otherwise indicated, all materials in this

More information

Dell SC7020 Storage Controller Getting Started Guide

Dell SC7020 Storage Controller Getting Started Guide Dell SC7020 Storage Controller Getting Started Guide Regulatory Model: E03T Regulatory Type: E03T001 Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better

More information

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9207-8e PCI Express to 6Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 2.3 DB15-000859-04 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy

Data Sheet Fujitsu Server PRIMERGY CX400 M1 Compact and Easy Data Sheet Fujitsu Server Compact and Easy Data Sheet Fujitsu Server Compact and Easy Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing The Fujitsu Server helps to meet the immense challenges

More information

RACK-220 CHASSIS USER S MANUAL

RACK-220 CHASSIS USER S MANUAL RACK-220 CHASSIS USER S MANUAL 1 Copyright Notice This document and product is copyrighted, Jun 1999, by ICP Electronics Inc. All rights are reserved. No part of this manual may be reproduced, copied,

More information

MIC Advantech CompactPCI. Modular Industrial Computer. 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane

MIC Advantech CompactPCI. Modular Industrial Computer. 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane MIC-3081 10U high 8-slot enclosure with CT bus and rear I/O for CompactPCI backplane Advantech CompactPCI Modular Industrial Computer Copyright Notice This document is copyrighted, 2003. All rights are

More information

SATA II HDD Canister KISS DA 435 Quick Reference Guide

SATA II HDD Canister KISS DA 435 Quick Reference Guide SATA II HDD Canister KISS DA 435 Quick Reference Guide If it s embedded, it s Kontron 1. Table of Contents SATA II HDD Canister KISS DA 435 1. Table of Contents 1. Table of Contents... 1 2. Important Information...

More information

Dell EMC PowerVault MD3460 Storage Arrays

Dell EMC PowerVault MD3460 Storage Arrays Dell EMC PowerVault MD3460 Storage Arrays Owner's Manual Regulatory Model: E08J Series Regulatory Type: E08J001 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you

More information

TESLA 1U GPU COMPUTING SYSTEMS

TESLA 1U GPU COMPUTING SYSTEMS TESLA 1U GPU COMPUTING SYSTEMS SP-04975-001_v02 March 2010 Specification DOCUMENT CHANGE HISTORY SP-04975-001_v02 Version Date Authors Description of Change 01 November 13, 2009 GG, SM Preliminary Information

More information

Installing the NVR Connectivity and 2nd CPU Kits 1

Installing the NVR Connectivity and 2nd CPU Kits 1 Installing the NVR Connectivity and 2 nd CPU Kits Avigilon provides two optional kits for network video recorders (NVR): NVR Connectivity Kit (HD-NVR3-PRMEXP-DAS-CONNECT-KIT) provides all the components

More information

Xpander Rack Mount 8 5U Gen 3 User Guide

Xpander Rack Mount 8 5U Gen 3 User Guide Xpander Rack Mount 8 5U Gen 3 User Guide Xpander Rack Mount 8 5U is a rack mount PCI Express (PCIe) expansion enclosure that enables connection of 8 double-wide graphics or other controllers with top-connected

More information

McAfee Network Security Platform

McAfee Network Security Platform NTBA Appliance T-1200 and T-600 Quick Start Guide Revision C McAfee Network Security Platform This guide is a high-level description of how to install and configure McAfee Network Threat Behavior Analysis

More information

SCv3000 and SCv3020 Storage System. Owner s Manual

SCv3000 and SCv3020 Storage System. Owner s Manual SCv3000 and SCv3020 Storage System Owner s Manual Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

CHENBRO. 80H A0 Rev A0 User s Manual 01 / 03 / 2011

CHENBRO. 80H A0 Rev A0 User s Manual 01 / 03 / 2011 2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 CHENBRO Storage Chassis 2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 Rev A0 01 / 03 / 2011 1 2.5 HDD 8-Port 6Gb/s Backplane 80H10323406A0 Copyright Copyright

More information

Replacing a 3.5-inch disk drive

Replacing a 3.5-inch disk drive EMC VNXe Replacing a 3.5-inch disk drive 302-000-213 REV 02 July, 2015 This document describes how to replace a disk drive in a supported 12-slot disk enclosure: 12-slot disk processor enclosure (DPE)

More information

HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide. May 2003 (Third Edition) Part Number

HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide. May 2003 (Third Edition) Part Number HP ProLiant DL380 Generation 3 Server Maintenance and Service Guide May 2003 (Third Edition) Part Number 291916-003 2003 Hewlett-Packard Development Company, L.P. Microsoft, Windows, and Windows NT are

More information

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID Xserve RAID and Xserve RAID (SFP) Updated: 25 May 2004 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc.

More information

Dolphin DXE410 Expansion Chassis

Dolphin DXE410 Expansion Chassis Dolphin DXE410 Expansion Chassis User Guide Revision Information: Revision 2.0 Dolphin Interconnect Solutions, 225 Cedar Hill Street, Marlborough, MA 01752 www.dolphinics.com September 2008 Dolphin Interconnect

More information

Installing the IPS 4345 and IPS 4360

Installing the IPS 4345 and IPS 4360 CHAPTER 4 Installing the IPS 4345 and IPS 4360 Contents This chapter describes the Cisco IPS 4345 and the IPS 4360, and includes the following sections: Installation Notes and Caveats, page 4-1 Product

More information

Tiger Box Expansion Chassis Assembly Guide

Tiger Box Expansion Chassis Assembly Guide Tiger Box Expansion Chassis Assembly Guide Product Overview................................. 3 Tiger Box Expansion Chassis Features............... 3 Package Content............................. 4 Hardware

More information

HYPER-UNIFIED STORAGE. Nexsan Unity

HYPER-UNIFIED STORAGE. Nexsan Unity HYPER-UNIFIED STORAGE Nexsan Unity Storage Expansion Reference Guide Unity v. 5.1 NEXSAN 325 E. Hillcrest Drive, Suite #150 Thousand Oaks, CA 91360 USA Printed Wednesday, November 28, 2018 www.nexsan.com

More information

Intel Server Board S3200SH, Intel Server System SR1530SH Intel Server System SR1530HSH Spares / Parts List & Configuration Guide

Intel Server Board S3200SH, Intel Server System SR1530SH Intel Server System SR1530HSH Spares / Parts List & Configuration Guide Intel Server Board S3200SH, Intel Server System SR1530SH Intel Server System SR1530HSH Spares / Parts List & Configuration Guide A reference guide to assist customers in ordering the necessary components

More information

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server

Data Sheet FUJITSU Server PRIMERGY CX400 M1 Scale out Server Data Sheet FUJITSU Server Scale out Server Data Sheet FUJITSU Server Scale out Server Scale-Out Smart for HPC, Cloud and Hyper-Converged Computing FUJITSU Server PRIMERGY will give you the servers you

More information

PCIE PCIE GEN2 EXPANSION SYSTEM USER S MANUAL

PCIE PCIE GEN2 EXPANSION SYSTEM USER S MANUAL PCIE2-2711 PCIE GEN2 EXPANSION SYSTEM USER S MANUAL The information in this document has been carefully checked and is believed to be entirely reliable. However, no responsibility is assumed for inaccuracies.

More information

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0 4-Bay Rack Mount Chassis User Manual February 6, 2009 - v1.0 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM esata equipped

More information

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003

Dell PowerEdge FD332. Owner's Manual. Regulatory Model: E02B Regulatory Type: E02B003 Dell PowerEdge FD332 Owner's Manual Regulatory Model: E02B Regulatory Type: E02B003 Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your computer.

More information

Introduction...1. Package Contents... 1 Product Features... 1 Specifications Product Schematic...2. HDD Installation...3

Introduction...1. Package Contents... 1 Product Features... 1 Specifications Product Schematic...2. HDD Installation...3 1 Table of Contents Introduction...1 Package Contents... 1 Product Features... 1 Specifications... 1 Product Schematic...2 HDD Installation...3 Connecting to your Computer...6 Connecting to Mac...7 Connecting

More information

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter

LSI SAS e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter LSI SAS 9300-8e PCI Express to 12Gb/s Serial Attached SCSI (SAS) Host Bus Adapter User Guide Version 1.3 DB15-000902-03 For a comprehensive list of changes to this document, see the Revision History. Corporate

More information

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved.

apple Service Source Xserve RAID 17 March Apple Computer, Inc. All rights reserved. apple Service Source Xserve RAID 17 March 2003 2003 Apple Computer, Inc. All rights reserved. apple Service Source Basics Xserve RAID 2003 Apple Computer, Inc. All rights reserved. Overview Xserve RAID

More information

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014

ETERNUS JX60. Technical Product Introduction. 0 Copyright Fujitsu, Release June 2014 0 Copyright Fujitsu, Release June 2014 Highlights The passive storage subsystem accommodates up to 240 HDDs 3.5" SAS 2.0 Nearline SAS 7200 rpm, max. storage capacity 960 TB 1) One or two 6 Gbit/s SAS interfaces

More information

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware.

Before you begin. Installation and Setup Instructions for E-Series 60-Drive Trays. Unpack & Prepare. Install Hardware. Connect Hardware. Before you begin Installation and Setup Instructions for E-Series 60-Drive Trays E760, E5560, and E5660 controller-drive trays DE6600 expansion drive trays Unpack & Prepare Install Hardware Connect Hardware

More information

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A

3-4 SAS/SATA II HDD Canister Entry version USER S MANUAL XC-34D1-SA10-0-R. Document number: MAN A 3-4 SAS/SATA II HDD Canister Entry version XC-34D1-SA10-0-R USER S MANUAL Document number: MAN-00077-A ii Preface Important Information Warranty Our product is warranted against defects in materials and

More information

Customer Upgrade Procedure

Customer Upgrade Procedure Customer Upgrade Dell EMC Unity Family Dell EMC Unity All Flash and Unity Hybrid Adding an optional 80-drive DAE disk drive 302-003-780 REV 01 July 2017 This document describes how to add an optional 80-drive

More information

NEC Express5800/R120e-1M System Configuration Guide

NEC Express5800/R120e-1M System Configuration Guide NEC Express5800/R120e-1M System Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and

More information