1 Nivowave Continuous level measuring system Table of contents Page Safety notes / Technical support G Applications / Overview G Function G Transducer selection guide G Evaluation overview G Technical data Dimensions G Electrical Data / Electronic G Mechanical Data G Operating conditions G Approvals G Accessories G Options G Mounting G Electrical installation Safety Instructions G Connection NW 00 to NW 00 G Power supply, -0mA, Relay output G0 Avoid of Cross Talking of multiple Transducers G Nivowave PC-converter G GSM Modem NW 000 G Modbus network G Profibus DP G Fieldbus Software G Notes for use in Hazardous Locations G0 Subject to technical change. We assume no liability for typing errors. Different variations than specified are possible. Please contact our technical consultants. NW gi00 page G

2 Nivowave Safety notes / Technical support Continuous level measuring system Notes Installation, maintenance and commissioning may be accomplished only by qualified technical personnel. The product must be used only in the manner outlined in this instruction manual. Special attention must be paid to warnings and notes as follows: WARNING Relates to a caution symbol on the product: A failure to observe the necessary precautions can result in death, serious injury and/or considerable material damage. WARNING A failure to observe the necessary precautions can result in death, serious injury and/or considerable material damage. CAUTION This symbol is used, when there is no corresponding caution symbol on the product. A failure to observe the necessary precautions can result in considerable material damage. Safety symbols In manual and on product Description CAUTION: refer to accompanying documents (manual) for details. Earth (ground) Terminal Protective Conductor Terminal Technical support Please get in contact to your local supplier (address see under uwt.de). Otherwise you can contact: UWT GmbH Tel.: 00 (0) -0 Westendstr. Fax. 00 (0) D- Betzigau info@uwt.de page G gi00 NW

3 Nivowave Continuous level measuring system Applications / Overview The Nivowave is a non intrusive acoustic wave measurement system. It is used for level monitoring of solids and liquids. It can be delivered with ATEX approval for use in Hazardous Locations. The Nivowave system is normally mounted at the top of the silo or tank. A selection of fields of applications and industries: Water / Waste water: Inlet screens, sumps, pump stations, water towers, dam level, chemical, open channel flow etc. Level measurement in solids Mining: Crushers, surge bins, ore passes, conveyor profile, blocked chute, stockpile, stackers, reclaimers, storage silos etc. Powers stations: Boiler bunkers, raw coal bunkers, ash pits, fly ash silos, etc. Food Plastics Chemicals Irrigation Cement Grain Paper Quarries Standard Series with horn for high performance in complex solid applications Integral NW 000 series Smart NW 000 series Remote NW 00 series (Transducer) With display and programming buttons implemented Without display and programming buttons. Programmable with Nivowave PC- software (optional) (optional) NW 00 (Level controller) Light series without horn for easy solid measurements in small vessels Integral NW 000L series Smart NW 000L series With display and programming buttons implemented Without display and programming buttons. Programmable with Nivowave PC- software NW gi00 page G

4 Nivowave Overview / Function Level measurement in liquids Integral NW 000L series Continuous level measuring system Smart NW 000L series Light series without horn for normal liquid applications With display and programming buttons implemented Without display and programming buttons. Programmable with Nivowave PC- software Integral NW 000 series Smart NW 000 series Standard Series with horn for high performance in complex liquid applications With display and programming buttons implemented Without display and programming buttons. Programmable with Nivowave PC- software Function The Nivowave emits a high powered acoustic wave transmit pulse which is reflected from the surface of the material being measured. The reflected signal is processed using specially developed software to enhance the correct signal and reject false or spurious echoes. The transmission of these high powered waves ensures minimal losses through the enviroment where the sensor is located. Due to the high powered emitted pulse, any losses have a far less effect than traditional ultrasonic devices. More energy is transmitted hence more energy is returned. The receiver circuitry is designed to indentify and monitor low level return signals even when noise levels are quite high. The measured signal is temperature compensated to provide maximum accuracy to the outputs and display. Advantages Large selection of transducers. No contact between the tranducer and the material. Suitable for measuring many different applications. Easy to calibrate and commission. Wireless monitoring and programming with GSM possible. page G gi00 NW

5 Nivowave Continuous level measuring system Transducer Selection guide Transducer selection by applications The following graphic is a guideline for the selection of the right transducer depending on the application. Anyway it is recommended to contact the local distributor to ensure a proper transducer selection fitting to the individual application. Liquids waveless x o ripply x o Solids granular x o powder x o Degree of difficulty Max. measurement distance Note: x Normal measurement o Measurement also during filling process or with strongly absorbent surface (e.g. cellulose, wood chips, foil snippet, foam formation) Measurement distance >m ( ft) on request Degree of difficulty Transducer ratings Light Series Standard Series Frequency Min. Blanking Distance Measurement Accuracy at ideal conditions (of adjusted range) Beam Angle Number of pulses per minute /-Wire V DC/ 0V AC -Wire ma -Wire 0mA NW...0L 0kHz 0, m ( ) +/- 0,% NW...0L 0kHz 0,0m ( ) +/- 0,% NW...0L 0kHz 0,m ( ) +/- 0,% NW...0 0kHz 0, m ( ) +/- 0,% NW...0 0kHz 0,m ( ) +/- 0,% 0 NW... khz 0,0m ( ) +/- 0,% 0 0 NW... khz,0m ( ) +/- 0,% 0 NW...0 0kHz,m ( ) +/- 0,% 0 0, NW gi00 page G

6 Nivowave Evaluation overview Continuous level measuring system Signal interface Integral NW 000 series Smart NW 000 series Remote Integral NW 000L series Smart NW 000L series NW 00 series (Transducer) NW 00 (Level controller) -0mA active -0mA passive -0mA HART Modbus Profibus DP () () Note: Available is GSD file; Read Only of measurement value Remote control Nivowave units with Modbus interface Modbus Nivowave PC-converter RS GSM-Modem NW 000 USB Nivowave PC-Software Programming, Diagnose, Display of Level measurement Nivowave PC-Software Programming, Diagnose, Display of Level measurement Touchscreen Visualisation of Level measurement (Panel mounting) page G gi00 NW

7 Nivowave Continuous level measuring system Technical Data Dimensions Standard series Integral NW 000 series Smart NW 000 series Remote NW 00 series Integral NW 000 series Smart NW 000 series Remote NW 00 series Selected Flange A B C E mm inch mm inch mm inch mm inch NW 00 NW 00 NW 0 DN0 / " NW 00 NW 00 NW 0 DN0 / " DN / " NW 0 NW 0 NW DN / " DN00 / " DN0 / " NW 0 NW 0 NW DN00 / " DN00 / " DN0 / " NW 00 NW 00 NW 0 DN00 / " DN0 / ".. () () ()... ().... ().. () Note: () Flexible polyurethan horn is used, which can be folded together to fit in the mounting nozzle NW gi00 page G

8 Nivowave Technical data Dimensions Light series Integral NW 000L series Continuous level measuring system Smart NW 000L series Level controller NW 00 GSM Modem NW 000 Flanges NW flanges Lk D d Holes fitting to mm inch mm inch mm inch number DN0 PN DN PN DN00 PN DN0 PN " bs ANSI " bs ANSI " bs ANSI " bs ANSI page G gi00 NW

9 Nivowave Continuous level measuring system Technical data Electrical data Connection terminals max..mm (AWG ) Cable entry NW 00: pieces M0 x. srewed cable gland and pieces blind plug NW 000L series, piece M0 x. srewed cable gland NW 000, NW 000L series, pieces M x. srewed cable gland and piece blind plug NW 000: pieces M0 x. srewed cable gland Extension cables for Remote Transducer and Modbus Specifications see in chapter "Electrical installation". Suggested cable types see in chapter "Accessories". Extension cables for Profibus DP Use common recommended Profibus cables Protection class I Installation category II Pollution degree Electronic -wire version /-wire version Supply voltage NW 00, NW 000, NW 000L series: - 0V DC (max. ripple = 0mV) NW 000, NW 000L series: - V DC (max. ripple = 0mV) All voltages incl. % of EN NW 00, NW 000, NW 000L series: - 0V DC (max. ripple = 0mV) 0-0V 0/0Hz (option) NW 000, NW 000L series: - V DC (max. ripple = 0mV) All voltages incl. % of EN Installed load max. 0,W max. W at V DC max. VA at 0V AC Signal output -0mA max. 0 Ohms (at V DC supply voltage) max. 0 Ohms (passive, at V DC supply voltage) max. 00 Ohms (active) Signal output Relay no relais avaliable x SPDT (NW 00) x SPST (NW 000, NW 000L series) x SPDT (NW 000, NW 000L series) Relay SPDT: max. 0V AC, 0.A, VA, non inductive max. 0V DC, 0.A, 0W Relay SPST: max. 0V DC, 0.A, non inductive Communication HART -0mA HART Rev Baud Rate = 0 Device number range 0- (selectable in menue) Voltage range: V DC Typical load: 0 Ohms same as for -wire version Communication Modbus Physical layer: RS and Ground Mode: RTU, Modbus type: Slave Device number range: - (selectable in menue) Baudrate: 00 Baud, Data bits:, Stop Bits: Parity: None Multi-drop configuration possible NW gi00 page G

10 Nivowave Technical data Communication Profibus DP Continuous level measuring system Physical layer: RS, isolated Type: Slave Device number range: 0 - (selectable in menue) Baudrate:. kbps to Mbps Display LCD display: line x digit (no display for Smart NW 000, NW 000L series) Available communication by GSD file, Read only LCD display: line x digit (no display for Smart NW 000, NW 000L series) Indicating light Status of relais by build in LED Memory Non-volatile (no backup battery required) > years data retention Non-volatile (no backup battery required) > years data retention Isolation Mechanical data AC Power supply to any output: 000Vrms DC Power supply to any output*: 00Vrms * Modbus is not isolated against DC power supply. Electronic Housing NW 00: Material: Plastic PC Colour: RAL 0 grey NW 000, NW 000L series: Material: Plastic Valox U Colour: RAL 0 gentian blue Transducer body Transducer face Process connection NW 00, NW 000, NW 000L, NW 000, NW 000L series: Housing material: Plastic Polypropylen (for ATEX: polypropylen / aluminium) Colour: RAL 0 grey Standard series NW 00, NW 000, NW 000 series, depending on selected model: Polyolfin version for dry/ condensed athmosphere, max +0 C (+ F) Teflon version for dry/ wet/ steamy athmosphere, max. + C (+ F) Light series NW 000L, NW 000L series: Teflon Titanium version for dry/ wet/ steamy athmosphere, max + C (+0 F) for dry/ wet/ steamy athmosphere, max. + C (+ F) Standard series NW 00, NW 000, NW 000 series: Flange material: Polypropylen version for 0 C ( F) and C ( F) Carbon version for C (0 F) Flange type: DIN or ANSI according to selection Light series NW 000L, NW 000L series: Polypropylen Horn Ingress protection Standard series NW 00, NW 000, NW 000 series: Horn material: Polypropylen or PUR version for 0 C ( F) and C ( F) Carbon version for C (0 F) Standard series: NW 00: IP (EN 0), NEMA X NW 00, NW 000 series: IP (EN 0) NW 000 series: IP (EN 0) Light series: NW 000L, NW 000L series: IP (EN 0) page G gi00 NW

11 Nivowave Continuous level measuring system Technical data Overall weight (ca.) NW 00: NW 00, NW 000 series: kg (.lbs) Transducer (without flange / horn) NW 0, NW 00 NW 0, NW 00 NW, NW 0 NW, NW 0 NW 0, NW 00 kg (. lbs).kg (. lbs) kg ( lbs) kg ( lbs) kg ( lbs) DN0 PN DN PN DN00 PN DN0 PN " lbs " lbs " lbs " lbs Flange incl. horn 0.kg (.lbs).kg (.0lbs).kg (.lbs).kg (.0lbs) 0.kg (.lbs).kg (.0lbs).kg (.lbs).kg (.0lbs) NW 000 series: NW 00 NW 00 NW 0 NW 0 NW 00 Housing with Transducer (without flange / horn) kg (. lbs).kg ( lbs) kg ( lbs) kg ( lbs) kg ( lbs) DN0 PN DN PN DN00 PN DN0 PN " lbs " lbs " lbs " lbs Flange incl. horn 0.kg (.lbs).kg (.0lbs).kg (.lbs).kg (.0lbs) 0.kg (.lbs).kg (.0lbs).kg (.lbs).kg (.0lbs) NW 000L series: NW 000L series: kg (. lbs) kg (. lbs) Operating conditions Ambient temperature (housing, outside process) All series: C ( F) C (-.. + F) ATEX version Process temperature Depending on selected model: NW 00 series: -0 C (-0 F).. +0 C ( F) / C ( F) / C (0 F) -0 C (- F).. +0 C ( F) / C ( F) ATEX version NW 000, NW 000 series: -0 C (-0 F).. +0 C ( F) / C ( F) -0 C (- F).. +0 C ( F) / C ( F) ATEX version NW 000 NW 000L, NW 000L series: -0 C (-0 F).. + C ( F) Max. process overpressure NW 00, NW 000, NW 000 series: 0mbar (.psi) NW 000L, NW 000L series: bar (psi) Relative Humidity Altitude 0-0%, suitable for outdoor use max..000m (.ft) Approvals General purpose CE EN - Hazardous Locations (optional) ATEX Dust Explosion ATEX II D and /D Ex td A0/ IP T C EMC EN -A Pressure Equipment Directive (//EC) The units are not subject to this directive, because they are classified as pressure-keeping equipment and do not have a pressurized housing (see Art., Abs...). The unit is NOT intended for use as a equipment part with safety function (Art., Abs...). If the units should be used as equipment part with safety function, please contact the manufacturer. NW gi00 page G

12 Nivowave Accessories GSM Modem NW 000 Continuous level measuring system Enables wireless control to a remote PC in combination with the Nivowave PC-Software. Modbus connection for direct connection to Nivowave units with Modbus signal output. Works as a Modbus master. Contact your local distributor for the definition of needed SIM-card and a receiver on the remote PC side. Network Type: Frequency 00/00 MHz 00 Baud (for USA) or Frequency 00/00 MHz 00 Baud (for Europe) Power supply: -0V DC or 0-0V AC Ambient temperature: C ( F) Ingress protection: IP (EN 0), NEMA X Overall weight: kg (.lbs) Nivowave PC-Software PC Software for Programming Diagnose Display of Level measurement Connection via RS (Modbus) to PC. To connect the PC, use the Nivowave PC-Converter More detailed information: See external manual of Nivowave PC-Software Nivowave PC-Converter USB to RS (Modbus) converter Connects a PC via USB to the Modbus output of series NW 00, NW 000, NW 000L, NW 000, NW 000L and NW 000. RS USB It works as a Modbus Master. It is used mainly for programming and diagnose of the Nivowave units. It provides no galvanic isolation between USB and RS. page G gi00 NW

13 Nivowave Continuous level measuring system Accessories Overview of mounting accessories Protection hose Hose conduit Terminal box PK/PK Mounting Plate PK UV protection cover Extension cable Terminal Box PK For extension of the connection cable of NW 00, NW 000, NW 000L series. Terminals integrated Cable glands pieces Mx. + blind plug Including Mounting Plate PK Ingress protection IP Ambient temperature: -0 C C (- C.. F) Dimensions PK: mm x mm (." x.") PK ATEX: 0mm x 0mm (." x.") Version PK ATEX for installation in ATEX Zone Certificate: ATEX II D Ex td A IP T0 C Modbus Terminal Box PK For installing a Modbus network with the Nivowave units Terminals integrated Cable glands pieces Mx. + blind plug Ingress protection IP Ambient temperature: -0 C C (- C.. F) Dimensions: PK: mm x mm (." x.") PK ATEX: 0mm x 0mm (." x.") Version PK ATEX for installation in ATEX Zone Certificate: ATEX II D Ex td A IP T0 C NW gi00 page G

14 Nivowave Accessories Cabeling system: Continuous level measuring system PK PK Modbus and Power supply Modbus and Power supply To Nivowave to Nivowave Optional also output from Nivowave : -0mA Relais Nivowave Optional also output from Nivowave : -0mA Relais Mounting Plate PK Used for mounting the Terminal box PK directly on the flange of the transducers Extension cables / cable protection For extending the cables of the Transducer NW 00 series and Smart NW 000, NW 000L series For wiring a Modbus network Notes for choosing the right cable see chapter "Electrical Installation" It is generally recommended to protect PVC signal cables from UV influence by installing them in pipes Shielded cable Cross section 0,mm (AWG) Capacitance nf/km (between wires) / 0nF/km (wire to shield) Common shield -0 C (- F) to 0 C ( F), PVC (LiYCY) Available with wires Twisted pair cable conductor twisted pair instrument cable Each twisted pair has a separate shield plus one common shield One twisted pair: cross section 0,mm (AWG), used for Power Supply line One twisted pair: cross section 0,mm (AWG), used for A/B line Impedance Ohms Capacitance 0nF/km (between twisted pair wires) - C ( F) to 0 C ( F), PVC Protection hose For installation of transducer cable or modbus cable in ATEX Zone Threaded hose coupling With thread Mx.. Fitting with protection hose. Applicable for ATEX Zone UV protection cover For installation of ATEX transducers in the sun With connection thread Mx, for mounting the threaded hose coupling Mounting kit Sealings, screws and washers for fixing the unit on a flange. page G gi00 NW

15 Nivowave Continuous level measuring system Accessories / Options Modbus Biasing Network PK Stabilizer for Modbus communication. Supports the needed Biasing voltages to ensure a proper function in a network with long installed cables. Implements the needed termination resistor for the beginning of the Modbus network. To be connected to V DC supply voltage. DIN Rail mounting. Can be placed in the PK Terminal box or in a cabinet. Modbus Termination Resistor PK Ohms resistor for the end of the Modbus network. DIN Rail mounting. Can be placed in the PK Terminal box. Modbus Terminal Clamps PK Option: Aiming kit Used for wiring a Modbus network inside the terminal compartment of the NW 00. Dimensions: xx0mm (0.x0.x0.") Set includes terminals (needed for one NW 00) For aiming the Transducer in the application. Necessary only in case of wrong echoes caused by ladders, beams and other fixtures in the vessel. Normal measurement of solids does NOT require aiming to the material angle of repose. The Aiming kit is optional available to the straight Tansducer fixing, which is delivered as standard. NW gi00 page G

16 Nivowave Mounting General Safety Instructions Continuous level measuring system Process pressure Chemical resistance against the medium Environment and installation conditions Industrial conditions Working temperature Mounting location Flange mounting Improper installation may result in loss of process pressure. Materials of construction are choosen based on their chemical compatibility (or inertness) for general purposes. For exposure to specific environments, check with chemical compatibility charts before installing. Do not put into service where there is a possibility of contact with acetic acid. Environment and installation conditions should be checked regularly This equipment is designed for use in normal industrial conditions relating to humidity, vibration, etc. If the user intends to operate the equipment in more severe environmental conditions, the manufacturer or local distributor should be consulted for advice. The working must not exceed the operating temperature range stated in the technical data. The right mounting place is significant for a proper function. Observe mounting instructions. A plastic sealing must be used to tighten the flange. Additional Safety Instructions for Hazardous Locations Installation regulations UV For devices to use in Hazardous Locations the respectively valid installation regulations must be observed. To prevent the effect of long term UV exposure, the transducers must be protected from direct sunlight. Amplifier mounting Mounting NW 00 and NW 000 Select a suitable mounting position that is not in direct sunlight. If necessary, utilize a sunshade. Observe the minimum and maximum temperature limits. Do not mount near sources of high E.M.F. such as high current cables, motor starters, or S.C.R. variable speed drives. Avoid mounting in high vibration areas. If necessary, use rubber absorption mounts if mounting in light vibration areas. page G gi00 NW

17 Nivowave Continuous level measuring system Mounting Transducer mounting Mounting position Selecting a suitable position to mount the transducer on the vessel is the most important step. Please read the following installation guide and contact your representative if you have any doubts or questions. A clear line of sight from the transducer to the product being monitored is preferred. First priority is to keep the transducer away from fill pipes, ladders, beams etc. Normal measurement of solids does NOT require aiming to the material angle of repose. Aiming the Transducer to the material angle of repose is only in seldom cases necessary. It is required, if any ladders, beams etc cause wrong echoes. In this case, use the Aiming kit to blank these wrong echoes. Solids Liquids Due to the high transmitted power of the transducer it is normally NOT necessary to aim the transducer to the material angle of repose. Enough echo is reflected by vertical mounting. Vertical mounting of transducer Vertical mounting of transducer Distance to vessel roof Standard series Light series Nozzle Horn The horn must protrude at least 0mm (") into the vessel. See in table on page G the dimension "B" of the horn. Use this value as a reference to define the max. height of the nozzle. The face (membran) of transducer must extend at least mm (0.") into the vessel. See dimension on page G. NW gi00 page G

18 Nivowave Mounting / Electrical installation Blanking distance Continuous level measuring system The transducer face must be at least the Blanking distance away from highest product level at all times. Increase the distance of the stated values by 0% if there is foam, dust, steam, or condensation in the vessel. Blanking distance Highest permitted product level Electrical installation Standard series Integral NW 000 series Smart NW 000 series Remote NW 00 series Min. Blanking Distance NW 00 NW 00 NW 0 0. m ( ) NW 00 NW 00 NW 0 0.m ( ) NW 0 NW 0 NW 0.0m ( ) NW 0 NW 0 NW.0m ( ) NW 00 NW 00 NW 0.m ( ) Light series Integral NW 000L series Smart NW 000L series Min. Blanking Distance NW 00L NW 00L 0. m ( ) NW 00L NW 00L 0.0m ( ) NW 00L NW 00L 0.m ( ) General Safety Instructions Handling In the case of inexpert handling or handling malpractice, the electric safety of the device cannot be guaranteed. Installation regulations Fuse RCCB protection Power supply switch Wiring diagram Supply voltage Cable gland The local regulations must be observed. Use a fuse to protect the power supply circuit and the output circuits. In the case of a defect, the distribution voltage must automatically be cut off by a RCCB protection switch so as to protect the user of the device from indirect contact with dangerous electric tensions. A voltage-disconnecting switch must be provided near the device. The electrical connections are made in accordance with the wiring diagram. Compare the supply voltage applied with the specifications given on the name plate before switching the device on. Make sure that the screwed cable gland safely seals the cable and that it is tight (danger of water intrusion). Cable glands that are not used have to be locked with a closing element. page G gi00 NW

19 Nivowave Continuous level measuring system Electrical installation Field wiring cables All field wirings must have insulation suitable for at least 0V AC. The temperature rating must be at least 0 C ( F). Connecting the terminals Make sure that max. mm (0, ) of the pigtails are bared (danger of contact with live parts). Relay protection Provide protection for relay contacts as to protect the device against spikes with inductive loads. Additional Safety Instructions for Hazardous Locations Installation regulations Cable glands Cables Earthing For devices to use in Hazardous Locations the respectively valid installation regulations must be observed. The used entry devices and blanking elements must have an adequate type approval and a temperature range of at least 0 C (- F) to +0 C ( F). In addition they shall be suitable for the conditions and correctly installed. Where applicable the provided original parts of the manufacturer must be used. To be compliant, the equipment must be installed with suitable protection for the cable. It must be protected in a suitable manner and terminated in an enclosure suitable for the environment. A pull relief must be provided for the cables, when the device is installed with the factory provided cable glands. Cables must only be replaced by the same cable type. If extending the cable, it must be protected in a junction box and terminated in an enclosure suitable for the environment. Where earth connection is present, the units must be earthed. Wiring / Hardware configurations Before making any wiring or hardware configuration changes, it is important to disconnect power from the equipment. Connection NW 00 to NW 00 Connection Transducer Recommended cables: Cable length <0m ( ft): Shielded cable (specifications see page G) Cable length >0m (ft) - 00m (0ft): Twisted pair cable (specifications see page G) Transmitter NW 00 max. 0m / 00m depending on used cable type connect shield to terminal "Black" * If the shield on the Transducer cable is not present, cut and dismantle the cable (shield is factory provided connected to black wire) Terminal box PK Red Black Blue White Shield* Transducer NW 00 series NW gi00 page G

20 Nivowave Electrical installation NW 00, NW 000, NW 000L series Power supply, -0mA output, Relay output Continuous level measuring system Power supply /-wire DC supply AC supply AC or DC supply depending on ordered version max..mm (AWG) -0mA output wire wire HART / wire / wire HART -0V DC Active (/ wire version) 0-0V AC Passive ( wire, / wire version) Note: Terminal "DC-IN -" and "Earth" are internally connected max..mm (AWG) max. 00 Ohm max. 0 Ohm at VDC supply voltage Relay output / wire / wire: Isolated output: can be made common with + or - of DC supply supply Power supply -0V DC Relay to max. Relay (depending on selected version) Independent programmable * Use shielded cable. Connect shield to either DCor Earth Switching logic: See describtion in the programming manual under "Output Adjustment Menue" Fuse: max. 0,A max. 0V AC, 0,A, VA, non inductive page G 0 gi00 NW

21 Nivowave Continuous level measuring system Electrical installation NW 000, NW 000L series Version with cable Cable colours Signal DC IN Comms -0mA Relais Connection Cable colour + - B A - + Red Black Blue White Green COM NO Yellow Brown Orange or pink TEST IN Purple Cables are present according to the ordered version Shield* NW 000, NW 000L series Version with cable Cable extension with Terminal Box PK Recommended cables: If "Comms" connection is only used to program or diagnose the unit (no evaluation in a Modbus network): Shielded cable (specifications see page G), max. cable length 0m (ft) If "Comms"connection is used in a Modbus network for evaluation: Twisted pair cable (specifications see page G), max. cable lenght 00m (0ft) * If the shield on the cable is not present, cut and dismantle the cable (shield is factory provided connected to black wire) Evaluation system max.cable length: see notes above NW 000, NW 000L series Version with cable Terminal box PK Red Black Blue White Shield** Green Yellow Brown Orange or pink * Use shielded cable. Connect shield to DC-. ** If the shield on the unit cable is not present, cut and dismantle the cable (shield is factory provided connected to black wire) NW gi00 page G

22 Nivowave Electrical installation NW 000, NW 000L series Power supply, -0mA output, Relay output Continuous level measuring system Power supply /-wire Version with junction box max..mm (AWG) Version with cable DC IN + - Red Black -V DC -V DC -0mA output (passive) wire / wire Version with junction box max..mm (AWG) Version with cable -0mA - + Green Yellow -V DC max. 0 Ohm at VDC supply voltage / wire: Isolated output: can be made common with + or - of DC power supply -V DC * Use shielded cable. Connect shield to DCmax. 0 Ohm at VDC supply voltage Relay output / wire Version with junction box Version with cable Relay max..mm (AWG) COM Brown NO Orange or pink Relay available Fuse: max. 0,A Fuse: max. 0,A max. 0V DC, 0, A non inductive max. 0V DC, 0, A non inductive page G gi00 NW

23 Nivowave Continuous level measuring system Electrical installation NW 00, NW 000, NW 000L, NW 000, NW 000L series Avoid of Cross Talking of multiple Transducers Cross Talking situation When installing more than one Transducer in a silo, it can happen, that one Transducer influences the other, which can lead to a wrong measurement. To avoid this, following wiring and programming is recommended: Wiring To reach a common ground for all Nivowaves, it is necessary either to connect all DC-IN - or all Earth terminals in parallel. Note: DC-IN - and Earth are connected together inside the Nivowave. To next Nivowave Programming In the software setup of each Nivowave (Output Adjust Menu), program Relay to FS (Failsafe) mode. You could use a different Relay number in the same way, if Relay is needed for another function. Function TEST IN connection: While the Transducer is pulsing, the TEST IN connection is driven to 0V by this Nivowave. While the TEST IN is set to 0V from outside (by another Nivowave), the Transducer will not pulse. The combination of these two functions avoid, that the Transducers can pulse at the same time. This means that no crosstalking can happen. To reach this, it is necessary to connect the TEST IN terminals of the Nivowaves together. Relay: The Relay (programmed into Failsafe mode) is in line with the TEST IN connection. The function of this is to prevent a possible lock up of the whole system if one Nivowave has a problem (such as power failure). Any time that a Nivowave is in the failed state, it will be disconnected by the Relay from the other Nivowaves, so they can continue working together. NW gi00 page G

24 Nivowave Electrical installation Nivowave PC-converter Continuous level measuring system Use of Nivowave PCconverter The Nivowave PC-converter works as a Modbus Master. It is used mainly for programming and diagnose. Powers supply is supported through USB. USB Modbus RS Cable colour: White Blue or Brown Black Connection Modbus Line A Modbus Line B Shield Connecting Nivowave PC-converter to a single Nivowave unit CAUTION The converter is not isolated between USB and RS side. Take care, that the used PC or Laptop is galvanically isolated from Earth. Connection without Biasing network Connection with Biasing network PK In case of a unstable network the use of the Biasing network PK is recommended. USB Nivowave PC-converter White Blue Black max. cable length: 0m USB Nivowave PC-converter White Blue Black Biasing network PK DC-, DC+ = V Supporting voltage for the Biasing network max. cable length: 0m Connecting Nivowave PC-converter to a Modbus Network CAUTION * Connect shield to either "DC-IN -" or "Shld" or "Earth" It should be avoided, that another Modbus Master is connected together with the Nivowave PC-converter. The converter is not isolated between USB and RS side. Take care, that the used PC or Laptop is galvanically isolated from Earth. For permant installation it is recommended to use a converter, which has a galvanic isolation implemented. Nivowave PC-converter USB White Blue Black Connected with A/B lines of the Network cable* Connected with shield of the Network cable* *See Modbus networks on page G page G gi00 NW

25 Nivowave Continuous level measuring system Electrical installation GSM Modem NW 000 CAUTION General notes In case of combination of NW 000 with a -wire -0mA version of Nivowave: The Modbus inside the Nivowave is NOT galvanically isolated from the -0mA line. The power supply of the -0mA loop must be isolated from the NW 000 power supply (Earth for AC supply, DC+ and DC- for DC supply of NW 000). The GSM Modem NW 00 works as a Modbus Master. All terminals which are present on the NW 000 and which are not mentioned on this page are not used. Power supply DC supply AC or DC supply depending on ordered version AC supply max..mm (AWG) -0V DC 0-0V AC Note: Terminal "DC-IN -" and "Earth" are internally connected. Connecting NW 000 to a single Nivowave unit Connection without Biasing network Connection with Biasing network PK In case of a unstable network the use of the Biasing network PK is recommended.. NW 000 NW 000 Connecting NW 000 to a Modbus Network max. cable length: 0m * Connect shield to either "DC-IN -" or "Shld" or "Earth" CAUTION It should be avoided, that another Modbus Master is connected together with the NW 000. NW 000 Connected with A/B lines of the Network cable* Biasing network PK DC-, DC+ = V Supporting voltage for the Biasing network max. cable length: 0m Connected with shield of the Network cable* *See Modbus networks on page G NW gi00 page G

26 Nivowave Electrical installation Modbus: Installing a Modbus Network Continuous level measuring system General note Recommended cable for Modbus network The mentioned line "A" is connected to Modbus line "D", and line "B" to "D0". Twisted pair cable (specifications see page G) Modbus and DC supply in the same cable Cable colours in case of using NW 000, NW 000L series as a cable version Blue White Red Black Blue White Red Black max. lenght of branching 0m (ft) Blue White Red Black To Modbus Master Shield shall be connected to DC- Biasing network (with Termination resistor) A, B = Modbus RS DC-, DC+ = V Power supply Max. lenght of network: 00m (0ft) Max. Modbus units possible Termination resistor Additional use of -0mA output and Relay should be wired in a sparate cable, not mixed with the Modbus network. Note: Terminal "DC-IN -" and "Earth" are internally connected Modbus in a separate cable * Connect shield to either "DC-IN -" or "Shld" or "Earth" max. lenght of branching 0m (ft) To Modbus Master Shield shall be connected to Earth Biasing network (with Termination resistor) A, B = Modbus RS DC-, DC+ = V Supporting voltage for the Biasing network Max. lenght of network: 00m (0ft) Max. Modbus units possible Termination resistor Additional use of -0mA output and Relay should be wired in a sparate cable, not mixed with the Modbus network. page G gi00 NW

27 Nivowave Continuous level measuring system Electrical installation Modbus: Accessories for a Modbus Network Use of Biasing network PK PK is used to stabilize the Modbus network, if long cables are used. It implements also the needed Terminal resistor at the beginning of the network. Required voltage: DC+/DC- V DC The Biasing network with Terminal resistor can be part of a Modbus Master, or be a separate module. The design or the values of the components can be different, when using other suppliers of a biasing network. It must be able to ensure a proper working voltage of ca. 00mV between A and B, if none of the connected Modbus units is talking. Biasing network PK with integrated Terminal resistor Use of Terminal Box PK Termination resistor PK at the end of the Modbus network. To be connected to terminal and. Implementation on the Branching points of Modbus Incoming Modbus cable Outgoing Modbus cable Modbus cable to Nivowave Terminal: Connection Power supply DC+ Power supply DC- Modbus Line B Modbus Line A Modbus Shield Terminals for cable-extension of the -0mA and Relay output from NW 000 and NW 000L series (cable version) additional to the Modbus connection: Terminal: Connection -0mA - -0mA + Relay COM Relay NO Free terminal Use of Terminal clamps PK The terminal clamps PK enables safe and easy wiring of the Modbus cable inside the terminal compartment of NW 00. No extra terminal box is required. Terminal compartment of NW 00 Terminals of NW 00 Terminal clamps PK max..mm (AWG ) Incoming Modbus cable Outgoing Modbus cable NW gi00 page G

28 Nivowave Electrical installation / Fieldbus Software Profibus DP Continuous level measuring system Connection on NW 00 Profibus circuit is isolated Cabeling according to Profibus DP standards Fieldbus Software HART Supported commands HART Multidrop Combination with other fieldbusses Universal commands: Command (Dec): Function: 0 Read Unique Identifier Read Primary Variable Read Current and Percent Range Read Dynamic Variables and PV Current Write Polling Address Read Unique Identifier by Tag Read Message Read Tag, Descriptor and Date Read PV sensor information Read PV Output information Read Final Assembly Number Write Message Write Tag, Descriptor and Date Write Final Assembly Number Common practice commands: Command (Dec): Function: Write Primary Variable Damping value Write Primary Variable Range values Write Primary Variable Units Burst Mode Control The units will work in this way, if the current output at "ma Adj" and "0mA Adj" (in the "Output adjustment menue") is set to nearly the same value (according to the system requirement). The command to go to fixed current mode is not supported. Only one fieldbus can be used at the same time. The required bus can be choosen in the "Output Adjustment Menu" under "Comm Type". page G gi00 NW

29 Nivowave Continuous level measuring system Fieldbus Software Modbus Supported commands Reading: Support of all diagnostics and parameters using command 0 HEX : Read Holding Register Main important registers to be used are: 0 Dec Low Level Setpoint in mm 0 Dec High Level Setpoint in mm 0 Dec Displayed Distance in mm Note: Depending on the used Modbus Master the "0" of the register adress is not used. Writing: Support of all parameters using command 0 HEX : Write Single Register Not suported is command HEX : Write Multiple Register. Multi-drop network Combination with other fieldbusses Factory setting of adress is. Each unit which takes part of the network must be set to a individual adress. This is done in the "Output Adjustment Menu" under "Comm Type". Only one fieldbus can be used at the same time. The required bus can be choosen in the "Output Adjustment Menu" under "Comm Type". Profibus DP Data in GSD file Reading of measured distance between Transducer face and material (in mm): Byte: Describtion: Type: Value: Most significant Byte Unsigned Binary Less significant Byte Unsigned Binary Example: Byte = = Dec Byte = 0000 = Dec Value = x + = mm Combination with other fieldbusses Only one fieldbus can be used at the same time. The required bus can be choosen in the "Output Adjustment Menu" under "Comm Type". NW gi00 page G

30 Nivowave Notes for use in Hazardous Locations ATEX Zone classification Continuous level measuring system category usable in zone Dust applications D 0,, D, D * *) in case of conductive dust additional demands for the installation are possible General Notes Marking Devices with Ex approval are marked on name the plate Max. Surface Temperature Rated max. surface temperature (valid for max. ambient and process temperature as stated in the technical data): Nivowave units: C ( F) Terminal boxes PK ATEX and PK ATEX: 0 C ( F) Permitted zones for installation Transmitter NW 00 Transducer NW 00 series NW 000 series Terminal Box PK ATEX PK ATEX Zone Zone 0 Safe area Zone 0 Zone 0 Zone page G 0 gi00 NW

Nivotec 1. Table of contents. Level monitoring system NT 3500 Technical information / Instruction manual. Page

Nivotec 1. Table of contents. Level monitoring system NT 3500 Technical information / Instruction manual. Page Nivotec 1 Table of contents Page Safety notes / Technical support G ------------------------------------------------------------------------------------------------------ Overview G ------------------------------------------------------------------------------------------------------

More information

Level monitoring system NT 3500 Technical information / Instruction manual

Level monitoring system NT 3500 Technical information / Instruction manual Table of contents Safety notes / Technical support Page ------------------------------------------------------------------------------------------------------ Overview ------------------------------------------------------------------------------------------------------

More information

Gladiator Acoustic Switch Series

Gladiator Acoustic Switch Series A Higher Level of Performance Data Sheet Gladiator Acoustic Switch Series Non-contact Self Cleaning Blocked Chute Detection For more information, please visit > www.hawkmeasure.com Acoustic Cleaning Principle

More information

Gladiator. Vibration Smart Switch Series. Data Sheet. A Higher Level of Performance. A level switch for liquids and solids.

Gladiator. Vibration Smart Switch Series. Data Sheet. A Higher Level of Performance. A level switch for liquids and solids. A Higher Level of Performance Data Sheet Gladiator Vibration Smart Switch Series A level switch for liquids and solids For more information, please visit > www.hawkmeasure.com Overview The Gladiator Smart

More information

Acoustic Switch Series

Acoustic Switch Series A higher level of performance Data Sheet Acoustic Switch Series - Non-contact self cleaning blocked chute detection - Principle of Operation The Gladiator Acoustic Switch uses Acoustic Wave technology

More information

Continuous level measuring system NB 3000 Selection list

Continuous level measuring system NB 3000 Selection list Table of contents Page Overview 2 ------------------------------------------------------------------------------------------------------------------- Specifications 3 -------------------------------------------------------------------------------------------------------------------

More information

Gladiator. Vibration Smart Switch Series. Data Sheet. Overview. A Higher Level of Performance. A level switch for liquids and solids

Gladiator. Vibration Smart Switch Series. Data Sheet. Overview. A Higher Level of Performance. A level switch for liquids and solids Gladiator Admittance Smart Switch Series A Higher Level of Performance Data Sheet Gladiator Vibration Smart Switch Series A level switch for liquids and solids For more information, please visit > www.hawkmeasure.com

More information

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min.

Siemens AG Continuous level measurement - Radar transmitters. Configuration. Mounting on a nozzle. Installation min. Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Level monitoring system NT 4500 Technical information / Instruction manual

Level monitoring system NT 4500 Technical information / Instruction manual Nivotec 1 Table of contents Safety notes/ Technical support Page ------------------------------------------------------------------------------------------------------ Overview ------------------------------------------------------------------------------------------------------

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

ULTRASONIC LEVEL METERS ULM 53L

ULTRASONIC LEVEL METERS ULM 53L Preliminary data ULTRASONIC LEVEL METERS ULM 53L For continuous level measurement of liquids (even if polluted), mash and paste materials in open or closed vessels, sumps, open channels, etc. Customer

More information

Series ULT Ultrasonic Level Transmitter

Series ULT Ultrasonic Level Transmitter Bulletin L-45 Series ULT Ultrasonic Level Transmitter Specifications - Installation and Operating Instructions 3 29/32 [99.21] 4 9/32 [108.74] 2X 1/2 NPT ø3 21/64 [84.53] 8 1/16 [204.79] Series ULT Ultrasonic

More information

Ultrasonic Transmitters SITRANS LU150. Operating Instructions

Ultrasonic Transmitters SITRANS LU150. Operating Instructions Ultrasonic Transmitters Operating Instructions Edition 03/2016 Introduction 1 Description 2 Installing and mounting 3 Ultrasonic transmitters Operating Instructions Connecting 4 Commissioning 5 Operating

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

Flow Measurement SITRANS F US Inline

Flow Measurement SITRANS F US Inline Overview Function Displays and keypad Operation of the SITRANS FUS060 transmitter can be carried out using: Keypad and display unit HART communicator PC/laptop and SIMATIC PDM software via HART communication

More information

PanelView Plus/VersaView CE Terminals and Display Modules

PanelView Plus/VersaView CE Terminals and Display Modules Installation Instructions PanelView Plus/VersaView CE Terminals and Display Modules (Catalog Numbers 2711P-xxxxxx, 6182H-xxxxxx) English Inside: Overview...2 For More Information...2 Modular Components...3

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Continuous level measurement Radar transmitters

Continuous level measurement Radar transmitters Overview Configuration Mounting on a nozzle Min. clearance: 10 (0.4) Installation min. 1 000 (39) is a 2-wire 2 GHz pulse radar level transmitter for continuous monitoring of solids in storage vessels

More information

Gladiator Admittance Smart Switch Series

Gladiator Admittance Smart Switch Series A Higher Level of Performance Data Sheet Gladiator Admittance Smart Switch Series An All-round Point Level Switch For more information, please visit > www.hawkmeasure.com The is a third generation, state-of-the-art

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage.

Assembly. max Example: 2-wire connection IH More connection types see section electrical connections. Auxiliary voltage. Guided Level Radar Features Measurement independent of density, temperature, and dust Measurement also possible with foam on the surface Simple, menu-guided on-site operation with four-line plain text

More information

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual

CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 RS485 to 7x, 6x, 5x, 4x Multimode Fiber Optic Star Coupler User Manual CMU 100 / 2.5.6.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6.6 12, CMU 100 / 2.5.6.6.6.6.6.6 12, CMU 100 / 8.5.6.6.6.6.6.6 12,

More information

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description

RAD-DOR4-IFS. I/O extension module, 4 digital relay outputs. INTERFACE Data sheet. 1 Description I/O extension module, 4 digital relay outputs INTERFACE Data sheet 104834_en_01 PHOENIX CONTACT 2013-01-21 1 Description The RAD-DOR4-IFS I/O extension module can be used in conjunction with Radioline

More information

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882

1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 1/32-DIN TEMPERATURE CONTROLLER INSTALLATION, WIRING AND OPERATION MANUAL FORM 3882 This manual is intended for use in support of installation, commissioning and configuration of the 1/32-DIN Temperature

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2013 Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance

More information

Float Switches with Permanent Magnet For Vertical Installation Model RSM

Float Switches with Permanent Magnet For Vertical Installation Model RSM Level Measurement Float Switches with Permanent Magnet For Vertical Installation Model RSM WIKA Data Sheet LM 30.01 Applications Level measurement for almost all liquid media Pump/level control and monitoring

More information

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application

60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application WWW.PHIHONG.COM 60W Power over Ethernet Waterproof Adapter PoE IEEE BT Single Port Injector for Outdoor Application Features Compliant with the IEEE802.3bt Standard Non-Vented Case with Mounting Bracket

More information

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)

MODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz) Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2012 Level measurement Overview EchoMax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing

More information

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS

MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS MPI-DN, MPI-D MULTICHANNEL ELECTRONIC RECORDER for HART or RS-485/ MODBUS RTU SENSORS 18 channels for HART / Modbus RTU sensors 2 digital channels 16 math channels 4 relay outputs for alarm or control

More information

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK

Analyzer/Controller. ph/orp HART. Model 54e ph/orp ESSENTIAL INSTRUCTIONS WARNINGS RISK OF ELECTRICAL SHOCK Instruction Sheet PN 51A-54epH/rev J October 2010 ph/orp HART Model 54e ph/orp Analyzer/Controller For additional information, please visit our website at www.emersonprocess.com/raihome/liquid/. ESSENTIAL

More information

Product information Ultrasonic

Product information Ultrasonic Product information Ultrasonic Level measurement in liquids and bulk solids VEGASON 6 VEGASON 6 VEGASON 6 Document ID: 90 Contents Contents Measuring principle... Type overview... 4 Instrument selection...

More information

General-Purpose Photoelectric Sensor

General-Purpose Photoelectric Sensor General-Purpose Photoelectric Sensor Compact Limit Switch Style with Universal Supply FET output allows for solid state switching of AC or DC Universal AC/DC power supply Choose cable or connector types

More information

Continuous level measurement Ultrasonic transducers

Continuous level measurement Ultrasonic transducers Siemens G 2012 Level Measurement Overview Echomax XPS/XCT transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing

More information

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid

Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid Echotouch, EchoSpan & EchoSwitch Ultrasonic Liquid The Echotouch, EchoSpan and EchoSwitch are innovative ultrasonic liquid level sensor families that replace float, conductance and pressure sensors that

More information

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description

RAD-DI8-IFS. I/O extension module with 8 digital inputs or 2 pulse inputs. INTERFACE Data sheet. 1 Description I/O extension module with 8 digital inputs or 2 pulse inputs INTERFACE Data sheet 0483_en_00 PHOENIX CONTACT 203-04-05 Description The I/O extension module can be used in conjunction with Radioline wireless

More information

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions

DXTH DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY. Mounting and operating instructions DUAL DUCT SENSOR / SWITCH FOR TEMPERATURE AND HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL

More information

ABB Drives. User s Manual Modbus Adapter Module FMBA-01

ABB Drives. User s Manual Modbus Adapter Module FMBA-01 ABB Drives User s Manual Modbus Adapter Module FMBA-01 Modbus Adapter Module FMBA-01 User s Manual 3AFE68586704 REV A EN EFFECTIVE: 27.06.2005 2005 ABB Oy. All Rights Reserved. 5 Safety instructions

More information

Float Switches with Permanent Magnet For Horizontal Installation Model HIF

Float Switches with Permanent Magnet For Horizontal Installation Model HIF Level Measurement Float Switches with Permanent Magnet For Horizontal Installation Model HIF WIKA Data Sheet LM 30.02 Applications Level measurement for almost all liquid media Pump/level control Chemical

More information

Operating Instructions

Operating Instructions Introduction To protect the signal lines of field devices and systems in the cabinet against lightning. Pepperl+Fuchs covers the complete range of Surge Protection Barriers. Housing types Depending on

More information

Level Measurement Continuous level measurement - Ultrasonic transducers

Level Measurement Continuous level measurement - Ultrasonic transducers Overview transducers use ultrasonic technology to measure level in a wide range of liquids and solids. Benefits Integral temperature compensation Low ringing effect reduces blanking distance Optional foam

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Carbon Monoxide Sensor - ModBus

Carbon Monoxide Sensor - ModBus Introduction The CO Sensor uses an electrochemical sensor to monitor CO level in a range of 0 to 500 ppm and communicates via an RS-485 network configured for ModBus protocol. Before Installation Read

More information

Technical Information Promonitor NRF560

Technical Information Promonitor NRF560 TI00462G/08/EN/03.14 71264171 Products Solutions Services Technical Information For tank side monitor and control of Proservo NMS5 intelligent tank gauge Application is a monitoring unit for use with Proservo

More information

Operating instructions. Switching amplifier DN0210 DN / / 2015

Operating instructions. Switching amplifier DN0210 DN / / 2015 Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5

More information

F1000 User's Manual. (Version: V1.01)

F1000 User's Manual. (Version: V1.01) (Version: V1.01) Contents Chapter 1 Overview... 2 Chapter 2 Installation... 3 2.1 Installation guide... 3 2.1.1 Installation position... 3 2.1.2 NEMA4 standard installation... 3 2.1.3 Environment precautions...

More information

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER

ECHOMAX XPS-10 ULTRASONIC TRANSDUCER Datasheet ECHOMX XPS-10 ULTRSONIC TRNSDUCER Supplied by.com Call us on + (0)118 916 920 Email info@27able.com Overview transducers use ultrasonic technology to measure level in a wide range of liquids

More information

SMARTLINE RM76 Supplementary instructions

SMARTLINE RM76 Supplementary instructions SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the

More information

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34)

EE360. High-End Moisture in Oil Transmitter. Typical applications. Features EE360 EE360. (+34) is dedicated for reliable monitoring of lubrication, hydraulic and insulation oils as well as diesel fuel. In addition to highly accurate measurement of water activity (a w ) and temperature (T), calculates

More information

DR7100 SERIES Supplementary instructions

DR7100 SERIES Supplementary instructions DR700 SERIES Supplementary instructions Guided Radar (TDR) Level Instrument for 2-wire control systems Supplementary Instructions for ATEX applications AMETEK Drexelbrook - EDO -0-2, DR700-LM ATEX, Issue

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

Installation Manual Series PQ-L. Electronic Module. Bulletin /UK

Installation Manual Series PQ-L. Electronic Module.  Bulletin /UK Bulletin 5715-571 /UK Installation Manual Electronic Module Gutenbergstr. 38 41564 Kaarst, Germany Tel.: (+) 2131-513-0 Fax: (+) 2131-513-230 www.parker.com Copyright Ó 2000, Note This document and other

More information

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W

Output Signal Active Note DC V. Electrical Data Power Supply DC V, ±10%, 1.4 W Differential Pressure Sensor (Air) Differential pressure transmitter with 8 selectable ranges 0 to 5/10 V, 4 to 20 ma outputs and Modbus functionality. NEMA 4X / IP65 rated enclosure. For monitoring the

More information

CEM M-RS485 INSTRUCTION MANUAL (M014B A)

CEM M-RS485 INSTRUCTION MANUAL (M014B A) Communications interface CEM M-RS485 INSTRUCTION MANUAL (M014B01-03-14A) 2 SAFETY PRECAUTIONS Follow the warnings described in this manual with the symbols shown below. DANGER Warns of a risk, which could

More information

Smart Wireless THUM Adapter

Smart Wireless THUM Adapter Reference Manual Smart Wireless THUM Adapter www.rosemount.com Reference Manual Smart Wireless THUM Adapter Smart Wireless THUM Adapter Smart Wireless THUM Adapter Hardware Revision 1 HART Device Revision

More information

MODEL 8000MP LEVEL SENSOR

MODEL 8000MP LEVEL SENSOR 1 MODEL 8000MP LEVEL SENSOR INSTRUCTIONS FOR INSTALLATION, OPERATION & MAINTENANCE VISIT OUR WEBSITE SIGMACONTROLS.COM 2 SERIES 8000MP LEVEL SENSOR 1. DESCRIPTION The Model 8000MP Submersible Level Sensor

More information

Level Measurement Continuous level measurement - Ultrasonic controllers

Level Measurement Continuous level measurement - Ultrasonic controllers Continuous level measurement Ultrasonic controllers Overview is a versatile short to mediumrange ultrasonic single and multivessel level monitor/controller for virtually any application in a wide range

More information

EH-RIO IP67 Profibus-DP I/O modules

EH-RIO IP67 Profibus-DP I/O modules Installation Instructions EH-RIO IP67 Profibus-DP I/O modules (RIO-PBXDP8M12, -PBXDP8M8, -PBYTP8M12, -PBYTP8M8, -PBXYP8M12, -PBXYP8M8) M12 Style Connectors M8 Style Connectors 43819 The EH-RIO IP67 Profibus-DP

More information

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits

RHE16. Compact Multifunction Coriolis Flow Meter Transmitter. Features. Applications. Benefits RHE16 Compact Multifunction Coriolis Flow Meter Transmitter Features Extremely compact footprint ideal for embedding into small systems and machines Mount remotely or in compact form Low installation cost

More information

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features

TRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. This general purpose, 2-wire, to 20 ma loop powered transmitter is ideal for liquids, slurries, and bulk materials in open

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

Level Measurement Continuous level measurement - Ultrasonic transmitters

Level Measurement Continuous level measurement - Ultrasonic transmitters Overview Configuration is a short-range integrated ultrasonic level transmitter. It is intrinsically safe (ATEX, CSA, FM, IECEx, NEPSI), 2 wire, to 20 ma loop powered, ideal for liquids, slurries, and

More information

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2

Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 Electronic pressure measurement Pressure transmitter for highest pressure applications Up to 217,500 psi (15,000 bar) Model HP-2 WIKA data sheet PE 81.53 Applications Test bench construction Water jet

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

Level Measurement Continuous level measurement Ultrasonic controllers

Level Measurement Continuous level measurement Ultrasonic controllers Overview is a versatile short to mediumrange ultrasonic single and multivessel level monitor/controller for virtually any application in a wide range of industries. Application can be used with various

More information

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE

TraceTek Leak Detection Master Module Installation Instructions TOOLS REQUIRED STORAGE TTDM-128 TraceTek Leak Detection Master Module Installation Instructions TRACETEK APPROVALS AND CERTIFICATIONS TYPE NM General Signaling Equipment 76LJ GENERAL INFORMATION Please read these instructions

More information

IF-80x Outdoor Terminal

IF-80x Outdoor Terminal 95-10330_IF-800 V2016-10-20 Outdoor Terminal IF-80x Outdoor Terminal 1 IF-800 Outdoor / IF-801 We are pleased that you have decided to use a terminal of the IF-80x series for recording access data. Scope

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

RS-FS-N01 Wind speed transmitter user's Guide (485type)

RS-FS-N01 Wind speed transmitter user's Guide (485type) RS-FS-N01 Wind speed transmitter user's Guide (485type) Issue: V1.0 1 2 Context 1. Introduction... 4 2. Installation instructions...5 3. Configure the software installation and use... 6 4. Communication

More information

onlinecomponents.com

onlinecomponents.com R General-Purpose Fiber-optic Sensor Compact Limit Switch Style with Universal Supply H FET output allows for solid state switching of AC or DC H Universal AC/DC power supply H Choose cable or connector

More information

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide

Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Multi-instrument Communication, MIC-2 MKII DIN Quick Start Guide Warnings and legal information Installation and terminals Communication I/O options Alarming Utility software More information Specifications

More information

Level-Lance Model 5400A

Level-Lance Model 5400A Sales Manual Section 100 PRODUCT SPECIFICATION 5400A GENERAL DESCRIPTION The ROBERTSHAW Level-Lance Model 5400A is a microprocessor based, multi-point On-Off capacitance type level detection system. Utilizing

More information

InView Marquee Message Display

InView Marquee Message Display Installation Instructions InView Marquee Message Display Introduction These instructions show how to change the serial address and how to mount InView series signs with NEMA Types 4, 4X, and 12 enclosures.

More information

LC2300 Level Controller Installation and Maintenance Instructions

LC2300 Level Controller Installation and Maintenance Instructions 4025350/5 IM-P402-72 AB Issue 5 LC2300 Level Controller Installation and Maintenance Instructions 1 General safety information LC2300 2 General product information 3 Installation >50% >100%

More information

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES

SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES SYSTEM COMPONENTS SYSTEM COMPONENTS MODULES O U R P R O F E S S I O N MULTIFUNCTIONAL CURRENT CONTROLLED SWITCH MODULES MAIN FEATURES 4 20 ma input Relay output Rail mountable Intrinsically safe Associated

More information

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition).

*Approved by CSA for non-hazardous locations (Group Safety Publication IEC Third Edition). PowerCore Model MPC-20 Installation Manual *Approved by CSA for non-hazardous locations (Group Safety Publication IEC 61010-1 Third Edition). Products covered in this document comply with European Council

More information

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL

MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL MYRIAD QLC 4-CHANNEL MONITOR/CONTROLLER INSTRUCTION MANUAL VISIT OUR WEBSITE SIGMACONTROLS.COM MYR QLC MANUAL 013114 2 TABLE OF CONTENTS INTRODUCTION 3 Ordering Information Specifications Features WIRING

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual.

PHOENIX CONTACT - 11/2007. This data sheet is only valid in association with the IB IL SYS PRO UM E user manual. INTERBUS Inline Bus Coupler; Remote Bus Connections Via D-SUB Connectors REMOTE IN BA UL RD RC DSUB LD AUTOMATIONWORX Data Sheet 6362_en_03 PHOENIX CONTACT - 11/2007 REMOTE OUT Description The bus coupler

More information

Suitable for detecting transparent films or transparent bottles

Suitable for detecting transparent films or transparent bottles Ultrasonic Sensor Suitable for detecting transparent films or transparent bottles Reliable detection of transparent objects The sensor reliably detects transparent films or transparent objects. Only 16

More information

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller),

PHOENIX CONTACT Pin. SUBCON-PLUS M ARCNET, MULTI/MININET (B&R), SYSTEM 2003 (B&R), P-NET SUCONET K1, K2 (EATON/Moeller), Fast connector with screw terminal block connection for fieldbus systems Data sheet 00287_en_02 PHOENIX CONTACT 207-04-2 Description The SUBCON-PLUS/... D-SUB series is specifically designed for use in

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service.

QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB PM Series Power Meter. Safety Information. Equipment Maintenance and Service. PM Series Power Meter QUICK SETUP GUIDE PMC-1000, PMC-1001, PMM-1000, PMB-1960 Safety Information DANGER! HAZARD OF ELECTRIC SHOCK, EXPLOSION, OR ARC FLASH Follow safe electrical work practices. See NFPA

More information

Level gauges Series LS Level indicator, switch and transmitter for liquids

Level gauges Series LS Level indicator, switch and transmitter for liquids Level gauges Series LS Level indicator, switch and transmitter for liquids Simple construction Resistant under extreme temperature and pressure conditions No risk of leakage Measuring range: from 150 mm

More information

Model 7705 Control Module

Model 7705 Control Module www.keithley.com Model 7705 Control Module User s Guide PA-696 Rev. D / October 2006 A G R E A T E R M E A S U R E O F C O N F I D E N C E Safety Precautions The following safety precautions should be

More information

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS

OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS OPERATING INSTRUCTIONS 7 SERIES STATIC GENERATORS GB Contents Page 1 Introduction 4 2 Safety 5 3 Use 6 4 Checking on Delivered Equipment 6 5 General Specification and Dimensions 7 6 Positioning 10 7 Operating

More information

Millenium II +: general characteristics

Millenium II +: general characteristics Millenium II +: general characteristics Starter kit Blind Temperature sensors Special starter kits Bare board Power supply Level detection Local extensions Accessories Standard Expandable Adjacent extensions

More information

SUBCON-PLUS-PROFIB...

SUBCON-PLUS-PROFIB... Fast connector for PROFIBUS systems Data sheet 101610_en_10 PHOENIX CONTACT 2017-03-27 1 Description The SUBCON-PLUS-PROFIB... D-SUB series is specifically designed for use in PROFIBUS systems up to 12

More information

Thread length (overall length) material

Thread length (overall length) material Cylindrical Proximity Sensor for Mobile Usage Designed and tested to keep your machines moving IP69k tested and certified for highest water resistance e1 type approval (according to automotive directive

More information

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions

HITACHI. EH-150 series PLC EH-RTD8 Resistance Temperature Detective input module Instruction manual. Safety precautions HITACHI EH-150 series PLC Resistance Temperature Detective input module Instruction manual Thank you for purchasing a Hitachi Programmable Logic Controller. To operate it safely, please read this instruction

More information

RXTH DUAL ROOM SENSOR / SWITCH

RXTH DUAL ROOM SENSOR / SWITCH DUAL ROOM SENSOR / SWITCH FOR TEMPERATURE AND RELATIVE HUMIDITY Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE

More information

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway

Fieldgate SFG500. Technical Information. Intelligent Ethernet/PROFIBUS gateway Technical Information Fieldgate Intelligent Ethernet/PROFIBUS gateway Application Fieldgate is a system component that provides an independent access route to a PROFIBUS network. It may be used in a variety

More information

HART Density Gauge Datasheet

HART Density Gauge Datasheet HART Density Gauge Datasheet PRI 160 Pavilion 11, Coxwold Way Document Number : TD0015 Revision : A Issue : 0 Date : 31/03/2004 REVISION STATUS SIGNED / DATED A Original issue R. Field C Cunningham ISSUE

More information