Certificate of Compliance

Size: px
Start display at page:

Download "Certificate of Compliance"

Transcription

1 Certificate of Compliance Certificate: Master Contract: (104225_0_000) Project: Date ssued: ssued to: Siemens AG Östliche Rheinbrückenstr. 50 PD PA P R&D PM CRT Karlsruhe, Baden-Württemberg GERMANY Attention: Christian Haag The products listed below are eligible to bear the CSA Mark shown ssued by: Marin Banu Marin Banu PRODUCTS CLASS - C PROCESS CONTROL EQUPMENT-For Hazardous Locations- CLASS - C PROCESS CONTROL EQUPMENT-ntrinsically Safe, Entity - For Hazardous Locations- PROCESS CONTROL EQUPMENT CLASS PROCESS CONTROL EQUPMENT- ntrinsically Safe Entity For Hazardous Locations Type of Electro pneumatic Positioner SPART PS2 = 6DR5 6DR5ayb-0cdef-g**h Zjjj c = E / b = 0 Ex ib C T4/T6 Gb Cl Div. 1 Gr. A-D Entity Parameters, Temperature Codes and maximum Ambient Temperatures per nstallation Dwg A5E D Rev. 15 Enclosure Type 4X. CLASS PROCESS CONTROL EQUPMENT- For Hazardous Locations 6DR5ayb-0cdef-g**h Zjjj c = E / b = 5, 6 DQD 507 Rev Page 1

2 Certificate: Project: Master Contract: Date ssued: Ex db C T4/T6 Gb Cl Div. 1 Gr. C and D Ex tb C T100 C Db Cl, Div. 1 Gr. A-D Cl, Div. 1 Gr. E-G; Cl. nput rated 20mA, 35Vdc maximum. Ambient temperature range 30 C to 80 C max. CLASS PROCESS CONTROL EQUPMENT- ntrinsically Safe Entity For Hazardous Locations 6DR5ayb-0cdef-g**h Zjjj c = E / b = 1, 2, 3 Ex ib C T4/T6 Gb; Ex ib C, T130 C Db; Cl, Div. 1 Gr. A-D Cl, Div. 1 Gr. E-G; Cl. Entity Parameters, Temperature Codes and maximum Ambient Temperatures per nstallation Dwg A5E D Rev. 15 Enclosure Type 4X. CLASS PROCESS CONTROL EQUPMENT- For Hazardous Locations 6DR5ayb-0cdef-g**h Zjjj c = G / b = 1, 2, 3, 5, 6 Ex na C T4/T6; Cl Div. 2 Gr. A-D T4/T6 nput rated 20mA, 35Vdc maximum. Ambient temperature range 30 C to 80 C max. CLASS PROCESS CONTROL EQUPMENT- For Hazardous Locations 6DR5ayb-0cdef-g**h Zjjj c = D / b= 1, 2, 3 Ex tb C T100 C Db; Cl, Div. 1 Gr. A-D; Cl, Div. 1 Gr. E-G; Cl. Ex na C T4/T6 Gc; Cl Div. 2 Gr. A-D T4/T6 nput rated 20mA, 35Vdc maximum. Ambient temperature range 30 C to 80 C max. CLASS PROCESS CONTROL EQUPMENT- ntrinsically Safe Entity For Hazardous Locations 6DR5ayb-0cdef-g**h Zjjj c = K / b= 1, 2, 3; 5; 6 DQD 507 Rev Page 2

3 Certificate: Project: Master Contract: Date ssued: Ex ib C T4/T6 Gb; Ex ib C, T130 C Db; Cl, Div. 1 Gr. A-D Cl, Div. 1 Gr. E-G; Cl. Entity Parameters, Temperature Codes and maximum Ambient Temperatures per nstallation Dwg A5E D Rev. 15. Enclosure Type 4X. CLASS PROCESS CONTROL EQUPMENT- For Hazardous Locations Ex na C T4/T6 Gc; Cl Div. 2 Gr. A-D T4/T6 Ex tb C T100 C Db; Cl, Div. 1 Gr. A-D Cl, Div. 1 Gr. E-G; Cl. nput rated 20mA, 35Vdc maximum. Ambient temperature range 30 C to 80 C max. CLASS PROCESS CONTROL EQUPMENT- ntrinsically Safe Entity For Hazardous Locations 6DR5ayb-0cdef-g**h Zjjj c = F / b= 1, 2, 3; 5, 6 Ex ib C T4/T6 Gb; Ex ib C T130 C Db; Cl, Div. 1 Gr. A-D Cl, Div. 1 Gr. E-G; Cl. Entity Parameters, Temperature Codes and maximum Ambient Temperatures per nstallation Dwg A5E D Rev. 15 Enclosure Type 4X. CLASS PROCESS CONTROL EQUPMENT- For Hazardous Locations Ex na C T4/T6 Gc; Cl Div 2 Gp A-D T4/T6 nput rated 20mA, 35Vdc maximum. Ambient temperature range 30 C to 80 C max. TYPE DESGNATONS Options intend for Electro pneumatic Positioners: Designation Type number Type key Alarm module 6DR4004-6A e=1 DQD 507 Rev Page 3

4 Certificate: Project: Master Contract: Date ssued: SA module (slot initiators) 6DR4004-6G e=2 Mechanical limit switch module 6DR4004-6K e=3 Position feedback module 6DR4004-6J f=1 or f=3 EMC filter module 6DR4004-6F f=2 or f=3 nternal NCS module 6DR4004-5LE e=9 Z=L1A External position detection system in an Polycarbonate enclosure with potentiometer C73451-A430-D78 External position detection system in an aluminum enclosure with potentiometer 6DR4004-1ES External Non-Contacting Sensor (NCS) in aluminum enclosure 6DR4004-2ES Non contacting sensor (NCS) 6DR4004-6N**0-*** Pressure regulator G ¼ 6DR4004-3P h=9; jjj = R3A Pressure regulator ½ NPT 6DR4004-3PN h=9; jjj = R3B OPOS nterface 6DR4004-5PB b=0,1, 2, 3; jjj = K20 Entity Parameters, Temperature Codes and maximum Ambient Temperatures per nstallation Dwg A5E D Rev. 15 Enclosure Type 4X. APPLCABLE REQUREMENTS Not linked to the type key of the basic device Standard Year of issue Specification CAN/CSA-C22.2 No Electrical Apparatus for Explosive Gas Atmospheres Part 0: General Requirements CAN/CSA C22.2 No : Electrical Apparatus for Explosive Gas Atmospheres Part 1: Flameproof Enclosures "d" CAN/CSA-C22.2 No Electrical Apparatus for Explosive Gas Atmospheres Part 7: ncreased Safety "e CAN/CSA-C22.2 No Electrical Apparatus for Explosive Gas Atmospheres Part 11: ntrinsic Safety "i CAN/CSA-C22.2 No Electrical Apparatus for Explosive Gas Atmospheres Part 15: Construction, test and marking of type of protection "n" DQD 507 Rev Page 4

5 Certificate: Project: Master Contract: Date ssued: CAN/CSA-C22.2 No Electrical Apparatus for Explosive Dust Atmospheres Part 31: Equipment dust ignition protection by enclosure "t" CAN/CSA-C22.2 No. 25-M1966 Enclosures for Use in Class, Groups E, F and G Hazardous Locations CAN/CSA-C22.2 No.30-M1986 Explosion-Proof Enclosures for Use in Class Hazardous Locations CAN/CSA-C22.2 No. 94-M91 R1997 Special Purpose Enclosures CAN/CSA C22.2 No. C22.2 No Safety requirements for electrical equipment for measurement, control, and laboratory use Part 1: General requirements; 3 rd Edition CAN/CSA-C22.2 No ntrinsically Safe and Non-ncendive Equipment for Use in Hazardous Locations CSA C22.2 No Nonincendive Electrical Equipment for Use in Class and, Division 2 and Class, Divisions 1 and 2 Hazardous (Classified) Locations CAN/CSA-C22.2 No. 0-M91 R2001 General Requirements - Canadian Electrical Code, Part CAN/CSA C22.2 No Degrees of protection provided by enclosures (P Code) MARKNGS The manufacturer is required to apply the following markings: Products shall be marked with the markings specified by the particular product standard. Products certified for Canada shall have all Caution and Warning markings in both English and French. Additional bilingual markings not covered by the product standard(s) may be required by the Authorities Having Jurisdiction. t is the responsibility of the manufacturer to provide and apply these additional markings, where applicable, in accordance with the requirements of those authorities. DQD 507 Rev Page 5

6 Certificate: Project: Master Contract: Date ssued: The products listed are eligible to bear the CSA Mark shown with adjacent indicators 'C' and 'US' for Canada and US (indicating that products have been manufactured to the requirements of both Canadian and U.S. Standards) or with adjacent indicator 'US' for US only or without either indicator for Canada only. Markings appear on CSA accepted adhesive nameplates as per label drawing A5E and having following content according to the type code: D R 5 a y b - 0 c d e f - g * * h - Z j j j Type of Sipart PS2 Content Marking CSA Monogram CSA CSA Certificate Number CSA18CA X (all) Company name SEMENS Model name / number SPART PS2 6DR5* Serial number F-Nr. * b = 5 or 6 Uaux = 9 32V Electrical Ratings b = 0, 1,2 or 3 Uaux = 18 30V (all) Maximum Working Pressure p = bar b = 5 or 6 and c = E Ex db C, Ex tb C b = 1, 2, 3, 5 or 6 and c = F Ex ia C, Ex ic C, Ex ia C, Ex ec C b = 1, 2, 3, 5, or 6 and c = G Ex ec C Hazardous Location Designations Ex ia C, Ex ic C, b = 1, 2, 3, 5 or 6 and c = K Ex ia C, Ex ec C Ex tb C b = 0 and c = E Ex ia C, Ex ic C, b = 1, 2 or 3 and c = E Ex ia C, Ex ic C, Ex ia C, b = 1, 2 or 3 and c = D Ex ec C, Ex tb C Temperature Code T4/T6 Special purpose enclosure designation Type 4X (all) Do not open when an explosive atmosphere is present. Do not separate when energized. b = 0, 1, 2, or 3 and c = D, E, F, G, K, nstall per control drawing Warning A5E D Rev.15 b = 5 or 6 and c = E Seal all conduits within 18 inches (all) Potential electrostatic charging hazard b = 0, 1, 2, or 3 and c = D, E, F, G, K Use supply wires suitable for 20 K above Ta Markings for ntrinsic safety and Non-sparking protection - Submittor s name, tradename and/or CSA Master Contract ; - CSA certificate number CSA18CA X - Model designations; - CSA Monogram; DQD 507 Rev Page 6

7 Certificate: Project: Master Contract: Date ssued: Serial number or date code; - Hazardous Locations designations; - Special purpose enclosure designation, TYPE 4X; - Caution markings, WARNNG: Handle nstrument to avoid electrostatic charge appear in a visible manner on polymeric enclosure and nstall per Control Dwg A5E D, A5E AA or A5E AC. - WARNNG: Use supply wires suitable for 20K above Ta - WARNNG - EXPLOSON HAZARD SUBSTTUTON OF COMPONENTS MAY MPAR SUTABLTY FOR CLASS, DVSONS 1 and 2; - WARNNG - EXPLOSON HAZARD - DO NOT DSCONNECT WHLE CRCUT S LVE UNLESS - AREA S KNOWN TO BE NON-HAZARDOUS - The classification, Ex ib C as applicable; Optional marking: Class, Zone 1; Ex ib C as applicable. - The classification, Ex ib C as applicable; Optional marking: Zn 21 Ex ib C as applicable. - The classification, Ex na C as applicable; Optional marking: Cl Zn 2 Ex na C as applicable. Markings for Explosion-proof protection - Sbmittor s name, tradename and/or CSA Master Contract ; - CSA Monogram - CSA certificate number CSA18CA X - Company name - Model name / number - Serial number - Electrical Ratings and Maximum Working Pressure - Hazardous Location Designations - Ex db C/ Ex tb C - Temperature Code T4/T6 - Ambient Temperature Range - Enclosure Type and P rating - Warning re. Seal all conduits within 18 inches - Warning re. Do not open when energized appears on the cover only - The classification, Ex db C as applicable; Optional marking: Cl Zn 1 Ex db C as applicable. - The classification, Ex tb C as applicable; Optional marking: Zn 21 Ex tb C as applicable. Specific Conditions of Use The gaps of the equipment are increased to the safety level of EN table 2 (C). Repairs on flame-proof joints can only be done by original manufacturer. Explosive atmospheres are not allowed as pneumatic working medium. Only clean, dry and oil-free working medium is allowed. The electropneumatic positioner SPART PS2 type 6DR5ayb-0cdef-g**h-Zjjj can also be operated with clean dry natural gas, freely of additions at place of air. A requirement for operation with natural gas is the use of basic electronics and option modules taking into consideration the safety requirements of the type of protection Ex ia and an electric connection with protection level ia, Category 2G. Components that are used with this device have to be in accordance with actual ECEx standards, consist of actual ECEx certificates, and provide at least the minimum specifications of this device. Especially, DQD 507 Rev Page 7

8 Certificate: Project: Master Contract: Date ssued: unused openings have to be closed by ECEx certified blind-plugs. The carrier installed inside the housing is an integral part of the enclosure and is a part of the explosionproof concept. t s not allowed to use the enclosure without the carrier installed. Screws used for installing the carrier need to be fasten and secured according to manufacturer s requirements. Use within carbon disulphide atmospheres is not allowed. The electropneumatic positioner SPART PS2 type 6DR5ayb-0cdef-g**h-Zjjj has to be erected in such a way that the plastic window is only exposed to a low level of hazard of mechanical damage. The applied dust explosion protection by enclosure Ex tb C and Ex ia C respectively the type of protection ec C is not permitted for the electropneumatic positioner in plastic housing (b = 0). The electropneumatic positioner SPART PS2 and the option external position detection system with plastic housing (b = 0) shall be protected against the build-up of electrostatic charges. The connecting and disconnecting of the not energy limited circuits to the terminals and the plugging resp. unplugging of the M12 connector and of the internal plug- and socket connectors under voltage is permitted only if the presence of hazardous atmosphere can be excluded. The capacitance of the labels exceeds the allowed value of 3pF. Operating instructions must be observed. DQD 507 Rev Page 8

9 Supplement to Certificate of Compliance Certificate: Master Contract: (104225_0_000) The products listed, including the latest revision described below, are eligible to be marked in accordance with the referenced Certificate. Project Date Description Product Certification History Update of the CSA certificate , combined with CSA certificate DQD 507 Rev Page 1

10 Positioners Electropneumatic positioners Country-Specific Documentation Edition 05/2018 Answers for industry.

11

12 1.0 Description 1.1 Electropneumatic Positioner SPART PS2 The SPART PS2 electropneumatic positioner serves as a coupling module between closed-loop controller and pneumatic actuators. Together with the pneumatic actuator, it forms a control-loop in which the actual value x is the position of the drive rod with linear actuators or the position of the drive shaft with part-turn actuators and the command variable is the positioning current of a closed-loop controller or manual control station of 0/4 to 20 ma. By comparison between the set point and actual value, the microcontroller generates pneumatic positioning increments ± y which are applied to the actuator via piezo-pre controlled valves. The actuator volume integrates the positioning increments into the positioning pressure y which moves the drive rod or shaft approximately proportionally. The pneumatic actuators are available in single-acting and double-acting versions. n the case of the single-acting version, only one volume is aerated and vented; the resulting pressure works against a spring. n the case of the double-acting version, two volumes work against each other; when one volume is aerated, the other is vented. The following devices are suitable for potentially explosive atmosphere resp. indoor or outdoor use SPART PS2 6DR5ayb-*cdef-g*Ah-Z jjj 1.2 Non Contacting Sensor (NCS) The Non Contacting Position Sensor (NCS) is a sensor to detect valve and flap positions for the electro pneumatic positioner SPART PS2. The NCS and electro pneumatic positioner SPART PS2 can be mounted separately in all housing variants. The electropneumatic positioner SPART PS2 can then be mounted at some distance on a mounting tube or similar and is connected to the NCS by an electric cable. The NCS consists of a potted sensor and a magnet. The magnet is mounted directly on the spindle in linear actuators or on the drive shaft in part-turn actuators 1.3 External Position Detection System (EPDS) The positioner facilitates the separate installation of a position detection system, e. g. C73451-A430-D78. The stroke or rotary angle is recorded directly at the drive by means of an external position detection system. t is therefore possible to install the control unit at some distance away, e. g. on an assembly pipe or similar. The positioner is wired to the position detection system by means of electrical cable. The positioner is connected to the drive via one or two pneumatic lines. Such a separate installation is useful whenever the ambient conditions at the fitting exceed the specified positioner values. The external position detection system is mounted onto the console on part-turn actuators and to a bracket on linear actuators. The bracket can be a NAMUR type, or any other mounting bracket. Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/2018 1

13 2.0 Option modules The basic device can be equipped or retrofitted with the following different modules: Positioner SPART PS2 Designation Type no. Type code (1) Alarm module 6DR4004-6A g= 1 (2) SA module (Slot initiators) 6DR4004-6G g=2 (3) Mechanical limit switch module 6DR4004-6K g=3 (4) Position feedback module 6DR4004-6J h=1 resp. h=3 (5) EMC filter module 6DR4004-6F h=1 resp. h=3 (6) External position detection system C73451-A430-D78 not attached with the type code (7) Non contacting sensor (NCS) 6DR4004-6N**0-*** of basic device (8) nternal NCS module 6DR4004-5LE e=9 and Z= L1A (1) The alarm module provides 3 binary outputs and one binary input. The binary outputs can be used to monitor the manipulated variable for 2 limits as well as the microcontroller including its position control function for faults. (2) The SA module provides 3 binary outputs. n addition to monitoring the microcontroller with its position control function for faults, it is possible to monitor the valve position using 2 slot initiators even in the case of a device failure. (4) The manipulated variable y (valve position) can be output as a current (4 to 20 ma) by means of the position feedback module. (5) The EMC filter module is intend to connecting an external position detection system e. g. C74451-A430-D78 (6) or Non contacting sensor 6DR4004-6N**0-*** (7) for position feedback. The alarm (1) or SA module (2) or EMC filter module (5) or nternal NCS module (8) are intended to installed into the same slot. Therefore, the device can only be equipped with one of these modules. 3.0 Designation code Positioner SPART PS2: 6DR5ayb-0cdef-g**h-Z jjj a = 0, 2, 5 or 6 y = 1, or 2 b = 0, 1, 2, 3, 5, 6 c = E, G, D, F or K d = G, N, M, P, R or S e = 0, 1, 2, 3 or 9 f = 0, 1, 2 or 3 g = 0, 3, or 7 h = 0, 1, 2, 3, 4 or 9R** jjj = A20, A40; C20, D53, D54, D55, D56, D57, F01, K**, L1A, M40, R**, S**, Y** * = any character Frei verwendbar Siemens AG 2018, Control Drawing 2 A5E D-15, 05/2018

14 4.0 Max. permissible ambient temperatures ntrinsic safety (S) ncreased safety (ec) Type Designation T4 T6 SPART PS 2 positioner 6DR5ayb-*cdef-g*Ah-Z jjj -30 C Ta +80 C -30 C Ta +50 C SPART PS 2 positioner 6DR5ayb-*cdef-g*Ah-Z jjj with the data (Z = M40) -40 C Ta +80 C -40 C Ta +50 C SPART PS 2 positioner 6DR5ayb-*cdef-g*Ah-Z jjj with the data (a = 0. 2) and (e = 0, 1, 2, 3) and (f = 0, 2) -30 C Ta +80 C -30 C Ta +60 C SPART PS 2 positioner 6DR5ayb-*cdef-g*Ah-Z jjj with the data (a = 0. 2) and (e = 0, 1, 2, 3) and (f = 0, 2) (Z = M40) -40 C Ta +80 C -40 C Ta +60 C Option: Non contacting sensor (NCS) -40 C Ta +70 C 6DR4004-6N**0-*** -40 C Ta +90 C Option: External position detection system -40 C Ta +60 C C73451-A430-D78 / 6DR4004-1ES External Non-Contacting Sensor (NCS) 6DR4004-2ES -40 C Ta +90 C -40 C Ta +50 C Dust ignition proof (DP) Type Designation SPART PS2 positioner 6DR5ayb-*cdef-g*Ah-Z jjj with the data: c = D or K SPART PS2 positioner 6DR5ayb-*cdef-g*Ah-Z jjj with the data: c = D or K and -Z M40-30 C Ta +80 C -40 C Ta +80 C Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/2018 3

15 5.0 Explosion protection / EX Markings Electropneumatic positioner SPART PS2 6DR5ayb-0cdef-g**h Zjjj with the datas: c = E / b = 0 6DR5ayb-0cdef-g**h Zjjj with the datas: c = E / b = 5, 6 6DR5ayb-0cdef-g**h Zjjj with the datas: c = E / b = 1, 2, 3 6DR5ayb-0cdef-g**h Zjjj with the datas: c = G / b = 1, 2, 3, 5, 6 6DR5ayb-0cdef-g**h Zjjj with the datas: c = D / b= 1, 2, 3 6DR5ayb-0cdef-g**h Zjjj with the datas: c = K / b= 1, 2, 3; 5; 6 6DR5ayb-0cdef-g**h Zjjj with the datas: c = F / b= 1, 2, 3; 5, 6 EX MARKNGS Gas, type of protection by S FM + CSA: Cl Zn 1 AEx ib C Gb / Cl Zn 1 Ex ib C Gb S Cl Div 1 Gp A-D Gas, type of protection by XP FM: Cl Zn 1 AEx db C Gb / XP Cl Div 1 Gp A-D CSA Cl Zn 1 Ex db C Gb / XP Cl Div 1 Gp C-D Dust type of protection by DP FM + CSA: Zn 21 AEx tb C T100 C Db / Zn 21 Ex tb C T100 C Db DP Cl, Div 1 Gp E-G Gas, Dust type of protection by S FM + CSA: Cl Zn 1 AEx ib C Gb / Cl Zn 1 Ex ib C Gb Zn 21 AEx ib C, T130 C Db Zn 21 Ex ib C, T130 C Db S Cl,, Div 1 Gp A-G Gas, type of protection by N FM + CSA: Cl Zn 2 AEx na C Gc / Cl Zn 2 Ex na C Gc N Cl Div 2 Gp A-D Dust type of protection by DP: FM + CSA: Zn 21 AEx tb C T100 C Db / Zn 21 Ex tb C T100 C Db DP Cl, Div 1 Gp E-G Gas, type of protection by N FM + CSA: Cl Zn 2 AEx na C Gc / Cl Zn 2 Ex na C Gc N Cl Div 2 Gp A-D Gas, Dust type of protection by S FM + CSA: Cl Zn 1 AEx ib C Gb / Cl Zn 1 Ex ib C Gb Zn 21 AEx ib C, T130 C Db / Zn 21 Ex ib C, T130 C Db S Cl,, Div 1 Gp A-G Gas, type of protection by N FM + CSA: Cl Zn 2 AEx na C Gc / Cl Zn 2 Ex na C Gc N Cl Div 2 Gp A-D Dust type of protection by DP FM + CSA: Zn 21 AEx tb C T100 C Db / Zn 21 Ex tb C T100 C Db DP Cl, Div 1 Gp E-G Gas, Dust type of protection by S FM + CSA: Cl Zn 1 AEx ib C Gb / Cl Zn 1 Ex ib C Gb Zn 21 AEx ib C T130 C Db / Zn 21 Ex ib C T130 C Db S Cl,, Div 1 Gp A-G Gas, type of protection by N FM + CSA: Cl Zn 2 AEx na C Gc / Cl Zn 2 Ex na C Gc N Cl Div 2 Gp A-D Frei verwendbar Siemens AG 2018, Control Drawing 4 A5E D-15, 05/2018

16 External position detection system C73451-A430-D78 External position detection system in an Polycarbonate enclosure with potentiometer 6DR4004-1ES External position detection system in an aluminum enclosure with potentiometer 6DR4004-2ES External Non-Contacting Sensor (NCS) in aluminum enclosure 6DR4004-6N External Non contacting sensor NCS EX MARKNGS Gas, type of protection by S FM + CSA: Cl Zn 1 AEx ib C Gb / Cl Zn 1 Ex ib C Gb S Cl Div 1 Gp A-D Gas, Dust type of protection by S FM + CSA: Cl Zn 1 AEx ib C Gb / Cl Zn 1 Ex ib C Gb Zn 21 AEx ib C T130 C Db / Zn 21 Ex ib C T130 C Db S Cl,, Div 1 Gp A-G Gas, type of protection by N FM + CSA: Cl Zn 2 AEx na C Gc / Cl Zn 2 Ex na C Gc N Cl Div 2 Gp A-D Dust type of protection by DP FM + CSA: Zn 21 AEx tb C T100 C Db / Zn 21 Ex tb C T100 C Db DP Cl, Div 1 Gp E-G Gas, Dust type of protection by S FM + CSA: Cl Zn 1 AEx ib C Gb / Cl Zn 1 Ex ib C Gb Zn 21 AEx ib C T130 C Db / Zn 21 Ex ib C T130 C Db S Cl,, Div 1 Gp A-G Gas, type of protection by N FM + CSA: Cl Zn 2 AEx na C Gc / Cl Zn 2 Ex na C Gc N Cl Div 2 Gp A-D Dust type of protection by DP FM + CSA: Zn 21 AEx tb C T100 C Db / Zn 21 Ex tb C T100 C Db DP Cl, Div 1 Gp E-G Gas, Dust type of protection by S FM + CSA: Cl Zn 1 AEx ib C Gb / Cl Zn 1 Ex ib C Gb Zn 21 AEx ib C T130 C Db / Zn 21 Ex ib C T130 C Db S Cl,, Div 1 Gp A-G Gas, type of protection by N FM + CSA: Cl Zn 2 AEx na C Gc / Cl Zn 2 Ex na C Gc N Cl Div 2 Gp A-D Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/2018 5

17 6.0 Safety Notes 6.1 Approved associated apparatus or approved barrier must be installed in accordance with manufacturer instructions. 6.2 Approved associated apparatus or approved barrier must meet the following requirements: Vo < Vi max. lo < i max. Po < Pi max. Ca >Ci+Ccable La >Li+Lcable 6.3 The maximum non-hazardous area voltage must not exceed 250 V. 6.4 The installation must be in accordance with the National Electrical Code NFPA 70, Article 504, 505, and ANS/SA-Rp The cable shield must be connected to earth potential in accordance with ANS/SA-Rp Use only supply wires suitable for 20 C above surrounding temperature. 6.7 Substitution of components may impair intrinsic safety. 6.8 Limited energy circuits (N, Ex ic) Class / Division 2 - Zone 2 application (non-incendive field wiring) Barrier for non-incendive field wiring is required for connection to power supply. Electrical parameters are the same as for intrinsic safety. Without the use of conduit, Associated non-incendive Field Wiring Apparatus is required for connection to the power supply. 6.9 None sparking circuits (N, Ex ec) / Dust ignition proof (DP, Ex tb) Class / Division 2 - Zone 2 application; Class, / Division 1 - Zone 21 application (DP): No barrier is required for division 2 / zone 2 resp. division 1 / zone 21 installation. Equipment must be wired per the NEC division 2 / zone 2 wiring methods ntrinsic safety (S, Ex ib) Division 1 / Zone 1 application: With type of protection ntrinsic safety (S), only for connection to certified intrinsic safety circuits 6.11 Diameter of cable for delivered cable gland is 6 to 12 mm and for the second cable gland with two cable entries it is 4 to 5 mm The position feedback module is only for use in temperature class T Before commissioning the indications of the protection type which are not being used has to be removed Only certified, intrinsic safety electric circuits must be connected as auxiliary power, control and signal current circuits. Frei verwendbar Siemens AG 2018, Control Drawing 6 A5E D-15, 05/2018

18 6.15 The electro pneumatic positioner SPART PS2 type 6DR5ayb-0cdef-g**h-Zjjj can also be operated with clean dry natural gas, freely of additions at place of air. A requirement for operation with natural gas is the use of basic electronics and option modules taking into consideration the safety requirements of the type of protection Ex ia and an electric connection with protection level ia, Category 2G Use within Carbon Disulphide atmospheres is not allowed Repairs on flame-proof joints can only be done by original manufacturer The carrier installed inside the housing is an integral part of the enclosure and is a part of the explosion proof concept. t s not allowed to use the enclosure without the carrier installed. Screws used for installing the carrier need to be fasten and secured according to manufacturer s requirements The electro pneumatic positioner SPART PS2 and the option external position detection system with plastic housing (b = 0) shall be erected in such a way that the plastic window is only exposed to a low level of hazard of mechanical damage The electro pneumatic positioner SPART PS2 and the option external position detection system with plastic housing (b = 0) shall be protected against the build-up of electrostatic charges The connecting and disconnecting of the not energy limited circuits to the terminals and the plugging resp. unplugging of the M12 connector and of the internal plug- and socket connectors under voltage is permitted only if the presence of hazardous atmosphere can be excluded The labels used on the device can reach a charging capacity of 5pF. Keep the device and the cables at a distance from strong electromagnetic fields. Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/2018 7

19 7.0 FSCO-Concept The FSCO Concept allows interconnection of intrinsic safety apparatus to associated apparatus not specifically examined in such combination. The criteria for interconnection is that the voltage (Ui or Vmax), the current (i or max) and the power (Pi or Pmax) which intrinsic safety apparatus can receive and remain intrinsic safety, considering faults, must be equal or greater than the voltage. (Uo or Voc or Vt), the current (o or sc or i) and the power (Po or Pmax) levels which can be delivered by the associated apparatus, considering faults and applicable factors. n addition, the maximum unprotected capacitance (Ci) and inductance (Li) of each apparatus (other than the termination) connected to the fieldbus must be less than or equal to 5 nf and 10 μh respectively. n each segment only one active device, normally the associated apparatus, is allowed to provide the necessary energy for the fieldbus system. The allowed voltage Uo (or Voc or Vt) of the associated apparatus is limited to the range of 14 V DC to 24 V DC. All other equipment connected to the bus cable has to be passive, meaning that they are not allowed to provide energy to the system, except to a leakage current of 50 μa for each connected device. Separately powered equipment needs a galvanic isolation to assure that the intrinsic safety fieldbus circuit remains passive. The cable used to interconnect the devices needs to have the parameters in the following range: loop resistance R. : Ω/km inductance per unit length L.: mh/km capacitance per unit length C.: nf/km C = Cline/ line Cline/screen, if both lines are floating or C = Cline/ line + Cline/screen, if the screen is connected to one line. Maximum allowed cable length: CLASS, ZONE 1 ib length of spur cable: length of trunk cable: total length (sum of trunk and spur cables): length of splice 30 m 5 km 5 km 1 m At each end of the trunk cable an approved infallible line termination with the following parameters is suitable: R = W C = μf One of the allowed terminations might already be integrated in the associated apparatus. The number of passive devices connected to the bus segment is not limited due to.s. reasons. lf the above rules are respected, up to the specified total length, the inductance and capacitance of the cable will not impair the intrinsic safety or the installation. Frei verwendbar Siemens AG 2018, Control Drawing 8 A5E D-15, 05/2018

20 8.0 Block diagram FSCO Wiring Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/2018 9

21 9.0 Block diagram SPART PS2 (6DR50) / without HART / 2-wire operation nput Power Supply and Control Loop Binary nput Display Power supply 301R 619R 2 4V 2x 7V5 2x 22V 3V 2x 4V7 10µ GN D 3 But tons 10k C PU 10k 10 k GND 6R 4 Valve Driver 8x 4V7 GND 24V 10k 2x 4V7 2x 22V 2x 22V BN1 GN D X4 2x 619R 604R 604R P5 P6 P7 P8 EMC filter module 6DR4004-6F for extern al position detection system Filter X2 Vref Pot GND 3V Ribbon Cable 4 nternal Poti Piezo Va lves X5 X3 6 Rib bon Cable 8 = X3 = X # # = X1 A1 = A2 = X1 BN2 Mechan. Limit Switch Module 6DR4004-6K 3 1 V max 15V 3 2 max 25mA P max 64mW V max 30V max 100mA P max 0.75W SA Module 6DR4004-6G each circuit: V max 15V max 25mA P max 64mW 5 2 Alarm Module 6DR4004-6A circuit BN2: V max 25,2V other circuits: V max 15V max 25mA P max 64mW Position Feedback Module 6DR4004-6J for T4: V max 30V max 100mA P max 1W Ribbon Cable 6 V max 30V max 100mA P max 1W C73451-A nternal NCS module 6DR4004-5LE External Sensor: U o 5 V o 100 ma Po 33 mw Co 1uF Lo 1mH Ext. Sen sor Frei verwendbar Siemens AG 2018, Control Drawing 10 A5E D-15, 05/2018

22 10.0 Block diagram SPART PS2 (6DR52) / HART / 4-wire operation nput Power Supply V 30V max 100mA max P max 1W nput Control Loop 6 V max 30V max 100mA P max 1W Binary nput 10 Display Power supply 2k42 301R 619R 2 4V 2x 7V5 2x 22V 3V 2x 4V7 10µ GN D 3 Bu ttons H ART nterfa ce 10k 10k 1 0k GND 6R 4 Valve Driver 8x 4V7 GND 24 V 10k 2x 4V7 2x 22V 2x 22V GN D 2x 619R 604R 604R P5 P6 P7 P8 Piezo Valves X5 X3 6 Ribbon Cable 8 = X3 = X # # = X1 A1 = A2 = X1 BN2 Mechan. Limit Switch Module 6DR4004-6K 31 V max 15V 32 max 25mA P max 64mW V 30V max max 100mA P max 0.75W SA Module 6DR4004-6G each circuit: V max 15V max 25mA P 64mW max 52 Alarm Module 6DR4004-6A circuit BN2: V max 25,2V other circuits: V m ax 15V max 25mA P m ax 64mW for T4: V max 30V max 100mA P 1W max Ribbon Cable C73451-A CPU BN1 X4 EMC filter module 6DR4004-6F R ibb on Ca ble X2 4 for externa l position detection system Filter Vref Pot GND 3V nternal Poti nternal NCS module 6DR4004-5LE External Sensor: U o 5 V o 100 ma Po 33 mw Co 1uF Lo 1mH Ext. Sensor Position Feedback Module 6DR4004-6J Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/

23 11.0 Block diagram SPART PS2 PA (6DR55) Shut-down nput Vmax 30 V max 0.1 A Pmax 1 W FSCO-Source V max 17.5 V max 380 ma 6 P max 5.32 W any FM a. Barrier V max 24 V 7 max 200 ma P max 1.2 W 9 Binary nput 10 10k 2x 2V7 249k 2k21 VCC shutdown Display 10k SPC4 3 Buttons Psekundär < 150mW 40mA 2x 24V 301R 619R 24V CPU VCC SM1 GND 2x 4V7 10R 47µF Diode bridge GND GND 10µF VCC 10k 4 10k 8x 4V7 GND 8 100k VCC 24V 150k Valve Driver 100k GND 2x 604R 2x 604R P5 P6 P7 P8 Piezo Valve s X5 X3 6 Ribbon Cable = X3 = X # # = X1 A1 = A2 = X1 BN2 Mechan. Limit Switch Module 6DR4004-6K 31 V m ax 15.5V 32 max 25mA P m ax 64mW V m ax 30V 100mA max P m ax 0.75W SA Module 6DR4004-6G each circuit: V m ax 15.5V max 25mA P m ax 64mW 52 Alarm Module 6DR4004-6A circuit BN2: V max 25.2V other circuits: V max 15.5V max 25mA P max 64mW for T4: V max 30V max 100mA P 1W max Ribbon Cable A5E BN1 X4 EMC filter module 6DR4004-6F R ibb on Ca ble X2 4 fo r external position detection system Filter Vref Pot GND 3V nternal Poti nternal NCS module 6DR4004-5LE External Sensor: U o 5 V o 100 ma Po 33 mw Co 1uF Lo 1mH Ext. Sensor Position Feedback Module 6DR4004-6J Frei verwendbar Siemens AG 2018, Control Drawing 12 A5E D-15, 05/2018

24 12.0 Block diagram SPART PS2 FF (6DR56) Shut-down nput Vmax 30 V max 0.1 A Pmax 1 W FSCO-Source V max 17.5 V max 380 ma P max 5.32 W any FM a. Barrier 6 V max 24 V 7 max 200 ma P max 1.2 W 9 Binary nput 10 10k 2x 2V7 249k 2k21 VCC shutdown Display 10k SPC4 3 Buttons Psekundär < 150mW 40mA 2x 24V 301R 619R 24V CPU VCC SM1 GND 2x 4V7 10R 47µF Diode bridge GND GND 10µF VCC 10k 4 10k 8x 4V7 GND 8 100k VCC 24V 150k Valve Driver 100k GND 2x 604R 2x 604R P5 P6 P7 P8 Piezo Valve s X5 X3 6 Ribbon Cable = X3 = X # # = X1 A1 = A2 = X1 BN2 Mechan. Limit Switch Module 6DR4004-6K 31 V m ax 15.5V 32 max 25mA P m ax 64mW V m ax 30V max 100mA P m ax 0.75W SA Module 6DR4004-6G each circuit: V m ax 15.5V max 25mA P m ax 64mW 52 Alarm Module 6DR4004-6A circuit BN2: V max 25.2V other circuits: V max 15.5V max 25mA P max 64mW for T4: V max 30V max 100mA P max 1W Ribbon Cable A5E BN1 X4 EMC filter module 6DR4004-6F R ibb on Ca ble X2 4 fo r external position detection system Filter Vref Pot GND 3V nternal Poti nternal NCS module 6DR4004-5LE External Sensor: U o 5 V o 100 ma Po 33 mw Co 1uF Lo 1mH Ext. Sensor Position Feedback Module 6DR4004-6J Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/

25 13.0 Connection Overview Electropneumatic Positioner SPART PS2 / basic electronic 13.1 FOUNDATON Fieldbus (FF) / PROFBUS (PA) SPART PS2 6DR55**-*****-****-Z jjj (FF) SPART PS2 6DR56**-*****-****-Z jjj (PA) Class / Division 1 - Zone 1 application (S, Ex ib): Refer to safety notes clause 6.10 PROFBUS/ FOUNDATON Fieldbus circuit (terminals 6 and 7): Fieldbus FSCO-Model Vi =17.5 V i = 380 ma, Pi = 5.32 W C i = 0 L i = 8 μh FM approved barrier or power supply Vi =24 V i = 250 ma, Pi = 1.2 W C i = 0 L i = 8 μh Binary input circuit (terminals 9 and 10): Connected by jumper, or connection to switching contact. Shut down circuit (terminals 81 and 82): Vi = 30 V i = 100 ma Pi = 1 W, Ci = 0 Li = 0 Class / Division 2 - Zone 2 application / non incendive field wiring) (N, Ex ic): Refer to safety notes clause 6.8 PROFBUS/ FOUNDATON Fieldbus circuit (terminals 6 and 7): Vmax = 32 V C i = 0 L i = 8 μh Binary input circuit (terminals 9 and 10): Vo max = 5 V o max = 55 ma Shut down circuit (terminals 81 and 82): Vmax = 30 V i = 100 ma Class / Division 2 - Zone 2 application (N, Ex ec): Class, / Division 1 - Zone 21 application (DP, Ex tb): Refer to safety notes clause 6.9. PROFBUS/ FOUNDATON Fieldbus circuit (terminals 6 and 7): Un = 30 V n = 100 ma Binary input circuit (terminals 9 and 10): Vo max = 5 V o max = 55 ma Shut down circuit (terminals 81 and 82): Un = 30 V n = 100 ma Frei verwendbar Siemens AG 2018, Control Drawing 14 A5E D-15, 05/2018

26 Wire connection without HART SPART PS2 6DR50**-*****-****-Z-jjj Class / Division 1 - Zone 1 application (S, Ex ib): Refer to safety notes clause wire basic device without HART circuit 4 20mA (terminals 6 and 7/8): Vi =30 V i = 100 ma Pi =1 W Ci = 11 nf Li = 207 µh Binary input circuit (terminals 9 and 10): Connected by jumper, or connection to switching contact. Class / Division 2 - Zone 2 application / non incendive field wiring) (N, Ex ic): Refer to safety notes clause wire basic device without HART circuit 4 20mA (terminals 6 and 7/8): Vmax = 30 V max = 100 ma Binary input circuit (terminals 9 and 10): Vo max = 5 V o max = 0.25 ma Class / Division 2 - Zone 2 application (N, Ex ec): Class, / Division 1 - Zone 21 application (DP, Ex tb): Refer to safety notes clause wire basic device without HART circuit 4 20mA (terminals 6 and 7/8): Un= 30 V n= 100 ma Binary input circuit (terminals 9 and 10): Vo max = 5 V o max = 0.25 ma Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/

27 Wire connection with HART SPART PS2 6DR52**-*****-****-Z-jjj Class / Division 1 - Zone 1 application (S, Ex ib) Refer to safety notes clause wire basic device with HART circuit 4 20mA Power supply and control circuits connected in series, 4 to 20 ma Terminals 3 and 7/8; jumpers across terminals 4/5-6 With type of protection ntrinsic safety (S), only for connection to certified intrinsic safety circuits with the following maximum values: Vi = 30 V i = 100 ma Pi = 1 W Ci = 11 nf Li = 310 µh Binary input circuit (terminals 9 and 10): Connected by jumper, or connection to switching contact. Class / Division 2 Zone 2 application / non incendive field wiring (N, Ex ic): Refer to safety notes clause wire basic device with HART circuit 4 20mA. Vmax = 30 V max = 100 ma Binary input circuit (terminals 9 and 10): Vo max = 5 V o max = 0.25 ma Class / Division 2 Zone 2 application (N, Ex ec): Class, / Division 1 - Zone 21 application (DP, Ex tb): Refer to safety notes clause wire basic device with HART circuit 4 20mA. Un = 30 V n = 100 ma Binary input circuit (terminals 9 and 10): Vo max = 5 V o max = 0.25 ma Frei verwendbar Siemens AG 2018, Control Drawing 16 A5E D-15, 05/2018

28 13.4 3/4-Wire connection with HART SPART PS2 6DR52**-*****-****-Z-jjj Class / Division 1 - Zone 1 application (S, Ex ib) Refer to safety notes clause /4-wire basic device with HART Auxiliary power supply 18 to 30 V Terminals 2 and 4/5 Control current 4 to 20 ma: Terminals 6 and 7/8 4 Wire: Auxiliary power supply and control current electrical isolated. 3 Wire: Common base point Terminals 4/5 and 7/8 Vi = 30 V i = 100 ma Pi = 1 W Ci = 11 nf Li = 310 µh Binary input circuit (terminals 9 and 10): Connected by jumper, or connection to switching contact. Class / Division 2 Zone 2 application / non incendive field wiring (N, Ex ic): Refer to safety notes clause wire basic device with HART circuit 4 20mA. Vmax = 30 V max = 100 ma Binary input circuit (terminals 9 and 10): Vo max = 5 V o max = 0.25 ma Class / Division 2 Zone 2 application (N, Ex ec): Class, / Division 1 - Zone 21 application (DP, Ex tb): Refer to safety notes clause wire basic device with HART circuit 4 20mA. Un = 30 V n = 100 ma Binary input circuit (terminals 9 and 10): Vo max = 5 V o max = 0.25 ma Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/

29 14.0 Connection Overview Electropneumatic Positioner SPART PS2 / Options 14.1 Alarm module 6DR4004-6A Class / Division 1 - Zone 1 application (S, Ex ib) Refer to safety notes clause Binary output circuits (terminals 31 and 32, 41 and 42, 51 and 52) Safe electrical isolation from each other: Vi =15 V i = 25 ma Pi =64 W Ci = 5.2 nf Li = 0 µh Binary input circuit (terminals 11 and 12): Safe electrical isolation from the binary outputs and basic device: Vi =25.2 V Ci = 0 nf Li = 0 µh Binary input circuit (terminals 21 and 22): Jumpered, no electrical isolation from basic device: Vi =25.2 V Ci = 0 nf Li = 0 µh Class / Division 2 Zone 2 application / non incendive field wiring (N, Ex ic): Refer to safety notes clause 6.8. Binary output circuits (terminals 31 and 32, 41 and 42, 51 and 52) Safe electrical isolation from each other: Vmax =15 V max = 25 ma Ci = 5.2 nf Li = 0 µh Binary input circuit (terminals 11 and 12): Safe electrical isolation from the binary outputs and basic device: Vmax =25.2 V Ci = 0 nf Li = 0 µh Binary input circuit (terminals 21 and 22): Jumpered, no electrical isolation from basic device. Vo max = 5 V o max = 0.01 ma Class / Division 2 Zone 2 application (N, Ex ec): Class, / Division 1 - Zone 21 application (DP, Ex tb): Refer to safety notes clause 6.9. Binary output circuits (terminals 31 and 32, 41 and 42, 51 and 52) Safe electrical isolation from each other: Un =15 V n = 25 ma Binary input circuit (terminals 11 and 12): Safe electrical isolation from the binary outputs and basic device: Un =25.2 V Binary input circuit (terminals 21 and 22): Jumpered, no electrical isolation from basic device. Vo max = 5 V o max = 0.01 ma Frei verwendbar Siemens AG 2018, Control Drawing 18 A5E D-15, 05/2018

30 14.2 SA module 6DR4004-6G Class / Division 1 - Zone 1 application (S, Ex ib) Refer to safety notes clause Binary output circuit fault signal (terminals 31 and 32) Vi =15 V i = 25 ma Pi =64 W Ci = 5.2 nf Li = 0 µh Binary input circuits slot initiators (terminals 41 and 42, 51 and 52): Vi =15 V i = 25 ma Pi =64 W Ci = 161 nf Li = 120 µh Class / Division 2 Zone 2 application / non incendive field wiring (N, Ex ic): Refer to safety notes clause 6.8. Binary output circuit fault signal (terminals 31 and 32) Safe electrical isolation from each other: Vi =15 V i = 25 ma Binary input circuits slot initiators (terminals 41 and 42, 51 and 52): Safe electrical isolation from the binary outputs and basic device: Vi =15 V i = 25 ma Ci = 161 nf Li = 120 µh Class / Division 2 Zone 2 application (N, Ex ec): Class, / Division 1 - Zone 21 application (DP, Ex tb): Refer to safety notes clause 6.9. Binary output circuit fault signal (terminals 31 and 32) Safe electrical isolation from each other: Un =15 V n= 25 ma Binary input circuits slot initiators (terminals 41 and 42, 51 and 52): Safe electrical isolation from the binary outputs and basic device: Un =15 V n= 25 ma Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/

31 14.3 Position feedback module 6DR4004-6J Class / Division 1 - Zone 1 application (S, Ex ib) Refer to safety notes clause 6.10 / Only for use in temperature class T4 Current output circuit (terminals 61 and 62) Safe electrical isolation from inserted other modules and basic device: Vi =30 V i = 100 ma Pi =1.0 W Ci = 11 nf Li = 0 µh Class / Division 2 Zone 2 application / non incendive field wiring (N, Ex ic): Refer to safety notes clause 6.8 / Only for use in temperature class T4 Current output circuit (terminals 61 and 62) Safe electrical isolation from inserted other modules and basic device: Vmax =30 V max = 100 ma Class / Division 2 Zone 2 application (N, Ex ec): Class, / Division 1 - Zone 21 application (DP, Ex tb): Refer to safety notes clause 6.9 / Only for use in temperature class T4 Current output circuit (terminals 61 and 62) Safe electrical isolation from inserted other modules and basic device: Un =30 V n = 100 ma Frei verwendbar Siemens AG 2018, Control Drawing 20 A5E D-15, 05/2018

32 14.4 Limit switch module 6DR4004-6K Class / Division 1 - Zone 1 application (S, Ex ib) Refer to safety notes clause Binary output circuits (terminals 31 and 32) Safe electrical isolation from inserted other modules and basic device: Vi =15 V i = 25 ma Pi =64 W Ci = 5.2 nf Li = 0 µh Binary input circuit (terminals 41 and 42, 51 and 52): Safe electrical isolation from each other, other modules and basic device: Vi =30 V i = 100 ma Pi =750 mw Ci = 0 nf Li = 0 µh Class / Division 2 Zone 2 application / non incendive field wiring (N, Ex ic): Refer to safety notes clause 6.8. Binary output circuits (terminals 31 and 32) Safe electrical isolation from inserted other modules and basic device: Vi =15 V i = 25 ma Binary input circuit (terminals 41 and 42, 51 and 52): Safe electrical isolation from each other, other modules and basic device: Vi =30 V i = 100 ma Class, / Division 1 - Zone 21 application (DP, Ex tb): Refer to safety notes clause 6.9 / Only for use type of ignition DP Binary output circuits (terminals 31 and 32) Safe electrical isolation from inserted other modules and basic device: Un =15 V Un = 25 ma Binary input circuit (terminals 41 and 42, 51 and 52): Safe electrical isolation from each other, other modules and basic device: Un =30 V n = 100 ma Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/

33 14.5 EMC filter module 6DR4004-6F (For external position detection system) Potentially explosive atmosphere EMC filter module 6DR4004-6F External Position Sensor Vref Pot GND VCC Class / Division 1 - Zone 1 application (S, Ex ib) Refer to safety notes clause Class / Division 2 Zone 2 application / non incendive field wiring (N, Ex ic): Refer to safety notes clause 6.8. Supplied via basic device with Profibus PA (6DR55) resp. Foundation Fieldbus FF (6DR56) Terminals 1 4 Vo max =5 V o max = 112 ma Po max =120 mw Co max = 1 µf Lo max = 1 mh Supplied via other basic devices without HART (6DR50, 6DR640) resp. with HART (6DR52, 6DR642) Terminals 1 4 Vo max =5 V o max = 100 ma Po max =33 mw Co max = 1 µf Lo max = 1 mh Class / Division 2 Zone 2 application (N, Ex ec): Class, / Division 1 - Zone 21 application (DP, Ex tb): Refer to safety notes clause 6.9 Un =5 V Frei verwendbar Siemens AG 2018, Control Drawing 22 A5E D-15, 05/2018

34 14.6 Non contacting Sensor (NCS) 6DR4004-6N**-*** (Position sensor, connectable to EMC-Filter module 6DR4004-6F) Class / Division 1 - Zone 1 application (S, Ex ib) Refer to safety notes clause Wires x y Vi =5 V i = 160 ma Pi =120 W Ci = 110 nf +(690 pf/m) of connection cable Li = 270 µh + (6,58µH/m) of connection cable Class / Division 2 Zone 2 application / non incendive field wiring (N, Ex ic): Refer to safety notes clause 6.8. Wires x y Vmax =5 V max = 160 ma Ci = 110 nf +(690 pf/m) of connection cable Li = 270 µh + (6,58µH/m) of connection cable Class / Division 2 Zone 2 application (N, Ex ec): Refer to safety notes clause 6.9 / / Only for use type of ignition (N, Ex na) Wires x y Un =5 V n = 160 ma Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/

35 14.7 External position detection system (EPDS) 6DR4004-1ES (Passive Potentiometer into Aluminum enclosure connectable to EMC-Filter module 6DR4004-6F) Class / Division 1 - Zone 1 application (S, Ex ib) Refer to safety notes clause Terminal x y Vi =5 V Ci = 10 nf Li = 240 µh Class / Division 2 Zone 2 application / non incendive field wiring (N, Ex ic): Refer to safety notes clause 6.8. Terminal x y Vmax =5 V Ci = 10 nf Li = 240 µh Class / Division 2 Zone 2 application (N, Ex ec): Refer to safety notes clause 6.9 / / Only for use type of ignition (N, Ex ec) Wires x y Un =5 V Frei verwendbar Siemens AG 2018, Control Drawing 24 A5E D-15, 05/2018

36 14.8 External position detection system (EPDS) C73451-A430-D78 (Passive potentiometer into polycarbonat enclosure connectable to EMC filter module 6DR4004-6F) Class / Division 1 - Zone 1 application (S, Ex ib) Refer to safety notes clause Terminal x y Vi =5 V Ci = 10 nf Li = 240 µh Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/

37 15.0 M12 Connector configurations 15.1 List of available combinations M12 connector with basic electronics Optional design of M12 connector with basic device PA 6DR55 and FF 6DR Optional design of M12 connector with basic device with or without HART 6DR M12 connector with option modules Optional design of additional connector M12 to connection of the position feedback module 6DR4004-6J, ordering code -Z D Optional design of additional connector M12 to the connection of an external position detection system, ordering code -Z D Optional design of additional connector M12 to the connection of the output terminals Alarm module 6DR4004-6J // A1 resp. A2, ordering code -Z D Optional design of additional connector M12 to the connection of the output terminals SA module 6DR4004-6G // 1 resp. 2, ordering code -Z D Optional design of additional connector M12 to the connection of the output terminals Mechanical limit switch module module 6DR4004-6K // A1 resp. A2, ordering code -Z D M12 connector pin assignment 15.3 M12 connector diagrams Diagram 1: Basic electronics; (2-wire without HART Ex / non Ex) or (2-wire with HART non Ex) Diagram 2: Basic electronics, (PROFBUS PA Ex / non Ex) Diagram 3: Basic electronics (FOUNDATON Fieldbus Ex non EX Diagram 4: Second M12 connector wired to position feedback module 6DR4004-6J Diagram 5: Second M12 connector wired to EMC filter module for external position detection system Diagram 6: Second M12 connector wired to alarm module 6DR4004-6A Diagram 7: Second M12 connector wired to SA module 6DR4004-6G Diagram 8: Second M12 connector wired to Mechanical limit switch module module 6DR4004-6K Frei verwendbar Siemens AG 2018, Control Drawing 26 A5E D-15, 05/2018

38 M12 connector with basic electronics Optional design of M12 connector with basic device PA 6DR55 and FF 6DR56 The basic electronics of the SPART PS2 positioner in the design PA/FF (type key variable a = 5 or 6) is optionally connected via an M12 connector installed in the enclosure (type key variable d = R or S) to the bus voltage (max. Ui = 24 V, max. i = 380 ma). Terminal Polarity Braid Pin allocation connector Connection colour (see clause 2) 6 Blue 3 7 Brown 1 Screen Black 4 - unassigned White Optional design of M12 connector with basic device with or without HART 6DR50 The basic electronics of the SPART PS2 positioner in the design with or without HART (type key variable a = 0) is optionally connected via an M12 connector installed in the enclosure (type key variable d = R or S) to the control current (W 4 to 20 ma), terminal (6 + 7/8) at (max. Ui = 30 V) or (max. i = 100 ma). Terminal Polarity Braid Pin allocation connector Connection colour (see clause 2) 6 (-) Blue 3 7 (+) Brown 1 Screen Black 4 - unassigned White M12 connector with option modules Optional design of additional connector M12 to connection of the position feedback module 6DR4004-6J, ordering code -Z D53 By using the order code -Z D53), an additional M12 connector is electrically connected with the current output of the position feedback module 6DR4004-6J. The max. permissible electrical values are (max. Ui = 30 V), (max. i= 100 ma). Terminal Polarity Braid Pin allocation connector Connection colour (see clause 2) 62 (-) Blue 3 61 (+) Brown 1 Screen Black 4 - unassigned White Optional design of additional connector M12 to the connection of an external position detection system, ordering code Z D54 By using the order code -Z D54, an additional M12 connector is electrically connected with the EMC filter module 6DR4004-6F (f=2) to the connection of an external position detection system. The max. electrical values are (Uo max. = 5 V), (Po max. = 120 mw). Terminal Polarity Braid Pin allocation connector Connection colour (see clause 2) POT (X1/2) Potentiometer Blue 3 VCC (X1/4) (+) Brown 1 GND (X1/1) (-) Black 4 VREF (X1/3) Potentiometer slider White 2 Frei verwendbar Siemens AG 2018, Control Drawing A5E D-15, 05/

Refer to attachment for more details. Andreas Meyer

Refer to attachment for more details. Andreas Meyer IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

Intrinsic Safety Control Drawing

Intrinsic Safety Control Drawing s Intrinsic Safety Control Drawing system in total PLC PC Not hazardous area PROFIBUS DP Associated Apparatus Class I, DIV 2, GP A...D Class I, ZN 1, IIC T4 PROFIBUS-DP Ex i Terminating resistor Class

More information

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015

Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A /00 08/2015 Operating instructions (Safety-related part ATEX and IECEx) Inductive NAMUR sensors NN504A NN505A NN506A NN507A 80013497/00 08/015 Remarks for safe use in hazardous areas Functions and features Use in

More information

Safety Instructions Levelflex FMP50/51/52/53/54/55/56/57

Safety Instructions Levelflex FMP50/51/52/53/54/55/56/57 XA00531F-D/00/EN/16.16 71313127 Products Solutions Services Safety Instructions FMP50/51/52/53/54/55/56/57 4-20 ma HART Control Drawing IS Document: XA00531F-D Safety instructions for electrical apparatus

More information

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm. Short-circuit protection NCN-FK-N-V-V 002 Model Number NCN-FK-N-V-V Features Direct mounting on standard actuators Compact and stable housing with terminal compartment connection Fixed setting EC-Type Examination Certificate TÜV99

More information

FLEX Ex Spring Clamp Terminal Base

FLEX Ex Spring Clamp Terminal Base Installation Instructions FLEX Ex Spring Clamp Terminal Base (Cat. No. 1797-TB3S) 1 10 11 4 Only remove this cover plug if connecting another terminal base unit. 3 5 6 12 2 7 8 9 41253 Component Identification

More information

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth.

Do not open when energized or when an explosive atmosphere is present. Electrostatic hazard, clean only with damp cloth. D460/D470 Series - ATEX certified position transmitter nnnn II 2 GD ITS 11 ATEX 17431X Ex d IIC T* Gb Tamb -*ºC to +*ºC Ex tb IIIC T* Db Tamb -*ºC to +*ºC IP6X Ambient variation -60 C to +110 C (T4/T130

More information

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur. egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730-0 Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves Set point Travel 4 to 20 ma 5.3 to 200 mm The positioner

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity Certificate : IECEx PTB 04.0005 http://iecex.iec.ch/iecex/iecexweb.nsf/certificatesajax/iecex%20ptb%2004.0005%... Seite 1 von 4 10.01.2013 INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F

INSTRUCTION MANUAL. Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD PSD1000F PSD1000 - PSD1000F INSTRUCTION MANUAL Universal AC Input Switching Power Supply 24 Vdc Output DIN-Rail Models PSD1000, PSD1000F PSD1000 - Universal AC Input Switching Power Supply 24 Vdc Output ISM0089-4

More information

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description

FB-6SP and FB-12SP. Block device couplers. Data sheet 3177_en_A. 2 Features. 1 Description Block device couplers Data sheet 3177_en_A 1 Description PHOENX CONTACT 2015-01-20 2 Features The and block couplers provide an interface between the fieldbus trunk cable and field devices on Foundation

More information

5 Fieldbus Technology

5 Fieldbus Technology 5 Fieldbus Technology Ex e / Ex i 10922E00 The s Ex e/ex i connect intrinsically safe Foundation Fieldbus H1 or Profibus PA field devices to a non-intrinsically safe / Ex e trunk. Up to four intrinsically

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1746881 (024321_0_000) Issued to: Mine Safety Appliances Company North American Division 1000 Cranberry Woods Dr. Cranberry Township, Pennsylvania 16066-5296 USA

More information

MANUAL Surge Protectors

MANUAL Surge Protectors PROCESS AUTOMATION MANUAL Surge Protectors DP-LBF-I1.36.DE and DP-LBF- I1.36.IE With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery

More information

How to calculate an Intrinsically Safe loop approval.

How to calculate an Intrinsically Safe loop approval. MIE TALK - October 2016 How to calculate an Intrinsically Safe loop approval. EXPLOSIVE ATMOSPHERES Compile by: Gary Friend BSc PrEng, CEng MIET, Sales DirectorExtech Safety Systems (MTL, Beka Associates,

More information

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module)

MODEL: 6DV-B. [2] TERMINAL BLOCK 0: None (Euro terminal block at the rear of indicator module) Field-mounted Two-wire Signal Conditioners 6-UNIT -DIGIT LOOP POWERED INDICATOR (outdoor enclosure, intrinsically safe/explosion-proof) Functions & Features -digit LED display No external power source

More information

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur.

Segment Protector for Cabinet Installation R2-SP-IC* Features. Assembly. Function. Connection. Trunk, Ex na non-arcing. Spur. egment Protector for Cabinet nstallation Features Assembly 4... 12 outputs Ex ic (FCO or Entity) or non-incendive (Div 2) Advanced fault isolation at the spur egment Protector in Zone 2/Div. 2 nstruments

More information

Safety Instructions Cerabar M PMC51, PMP51, PMP55

Safety Instructions Cerabar M PMC51, PMP51, PMP55 XA00470P-B/00/EN/14.13 71224652 Products Solutions Services Safety Instructions PMC51, PMP51, PMP55 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6...T4 Ga/Gb Ex ia IIC T6...T3 Ga/Gb IECEx

More information

Series 3730 Type Electropneumatic Positioner

Series 3730 Type Electropneumatic Positioner Series 3730 Type 3730- Electropneumatic Positioner Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating, automatic adaptation to valve and

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel.

The 470-Z1 consists of an aluminium enclosure, which has the supply / interface connections either via the bottom side or enclosure back panel. February 23, 2018 Annexe to: IECEx CML 15.0097X Issue 4 Applicant: Apparatus: HMI Elements Limited 470-Z1 Module Description of Equipment The 470-Z1 is a mains supplied, transportable hazardous area

More information

General Specifications

General Specifications General Specifications Model MLX Loop Powered Process Indicator GS 60A02S01-01E-A The Model MLX Loop-Powered Process Indicator receives DC current signals from electronic transmitters and indicates process

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

Series 3730 Electropneumatic Positioner Type

Series 3730 Electropneumatic Positioner Type Series 3730 Electropneumatic Positioner Type 3730-0 Application Single-acting or double-acting positioner for attachment to pneumatic control valves Reference variable Travels 4 to 20 ma 5.3 to 200 mm

More information

Explosion Proof I/P Transducer

Explosion Proof I/P Transducer Type 950XP Explosion Proof I/P Transducer Installation, Operation and Maintenance Instructions 2" Pipe A 1 1/2" Pipe (49.5) 0 (88.9) (25.4) Holes for Mounting 1/2 NPT/M20 ("K" option) Port for Conduit

More information

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus

Cerabar S PMC71, PMP71, PMP ma HART, PROFIBUS PA, FOUNDATION Fieldbus Safety Instructions PMC71, PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex ia IIC T6 Ga/Gb IECEx KEM06.0011 0 XA00696P-D Safety instructions for electrical apparatus for explosion-hazardous

More information

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks

Sensor boxes SRBC. Festo core product range Covers 80% of your automation tasks Sensor boxes SRBC q/w Worldwide: Superb: Easy: Festo core product range Covers 80% of your automation tasks Always in stock Festo quality at an attractive price Reduces procurement and storing complexity

More information

Digital Positioner 8049

Digital Positioner 8049 Compact digital positioner for pneumatic control valves. Positioner can be integrated into valve actuator (no external moving parts for stroke feedback) Wide range of strokes - 8 mm No steady-state air

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70013111 (064969_0_000) Issued to: MSA - The Safety Company 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296 USA Attention: Stephen Kancel The

More information

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication

Series 3730 Electropneumatic Positioner Type with PROFIBUS-PA communication Series 3730 Electropneumatic Positioner Type 3730-4 with PROFIBUS-PA communication Application Positioner for attachment to pneumatic control valves Travels 3.6 to 200 mm Opening angle 24 to 100 Smart,

More information

Fisher i2p-100 Electro-Pneumatic Transducer

Fisher i2p-100 Electro-Pneumatic Transducer i2p-100 Transducer Product Bulletin Fisher i2p-100 Electro-Pneumatic Transducer The Fisher i2p-100 electro-pneumatic transducer, uses a converter module that converts a milliampere input to a proportional

More information

PI-EX-ME-2NAM/COC-24VDC

PI-EX-ME-2NAM/COC-24VDC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 4 V DC Supply INTERFACE Data Sheet 0033_0_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/COC-4VDC

More information

Assembly MAU. MUX 4 Channels 8 Channels Zone 1

Assembly MAU. MUX 4 Channels 8 Channels Zone 1 Multi-Input/Output Device for Cabinet Installation Features Assembly For discrete inputs and outputs Installation in Zone 1/Div. 1, intrinsically safe Sensors in Zone 0/Div. 1 Connection to fieldbus acc.

More information

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication

SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication R V Data Sheet 12.07 DS EVE0105 -(en) SRD991 Intelligent Positioner with HART, FoxCom, PROFIBUS-PA, FOUNDATION Fieldbus H1 or Without Communication The intelligent positioner SRD991 is designed to operate

More information

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069

INSTRUCTION MANUAL. SIL 3 Relay Output Module DIN-Rail Models D1092S-069, D1092D-069 D1092S D1092D-069 D09S09 D09D09 INSTRUCTION MANUAL SIL Relay Output Module DINRail Models D09S09, D09D09 D0909 SIL Relay Output Module ISM00 SIL Applications For Safety Related System and SIL, SIL Applications according

More information

Safety Instructions Cerabar S PMP71, PMP75

Safety Instructions Cerabar S PMP71, PMP75 /00/EN/01.14 71249311 Products Solutions Services Safety Instructions PMP71, PMP75 4-20 ma HART, PROFIBUS PA, FOUNDATION Fieldbus Ex d IIC T* Gb TÜV 13.0902X Segurança TÜV INMETRO OCP 0004 Document: Safety

More information

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi

Inductive angle sensor with analog output Ri360P1-DSU35TC-ELi-Exi ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detection of angular range 0 to 360 P1-Ri-QR14 positioning element included in delivery Measuring

More information

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex)

FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Data Sheet FieldIT Multi Barrier NMB204/NMB204-EX (MB 204/MB 204-Ex) Intrinsically safe power supply of up to 31 stations on the bus cascadable multi barrier Intrinsically safe connection of up to 4 field

More information

PHOENIX CONTACT - 12/2007

PHOENIX CONTACT - 12/2007 Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Active Transistor Output, Two-Channel INTERFACE Data Sheet 0943_00_en PHOENIX CONTACT - /007 Description The PI-EX-ME-NAM/TO-A is a two-channel

More information

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12

4 Remote I/O. Analog Output Module HART Ex i / I.S. Outputs, 8 Channels Series 9466/12 0 4 Remote I/O 8 channels for controlling HART control valves and positioners Intrinsically safe outputs Ex ia IIC Galvanic isolation between outputs and system Open-circuit and short-circuit monitoring

More information

Digital electropneumatic positioner

Digital electropneumatic positioner Digital electropneumatic positioner Type 879 can be combined with Compact metal housing Graphic display with backlight Easy start-up Comprehensive range of additional software functions Profibus DPV1 (optional)

More information

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters

System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters System 6000 Electropneumatic Converters (proportional valves) Electronic Controllers Signal Converters Edition November 2003 Information Sheet T 6000 EN Proportional valves e/p Converters Type 6 66 626

More information

PROFIBUS-PA Positioner Type 3785

PROFIBUS-PA Positioner Type 3785 PROFIBUS-PA Positioner Type 3785 Application Single-acting or double-acting PROFIBUS-PA positioner for attachment to pneumatic control valves. Rated travel from 7.5 to 120 mm Opening angle up to 120 Smart,

More information

Installation & Operation Manual

Installation & Operation Manual Via Enrico Fermi, 2 I-25015 Desenzano del Garda (BS) - Italy Phone: +39 030 7870787 Fax: +39 030 7870777 www.solexy.net BAF Intrinsically Safe Ethernet Coupler for signals operating in Hazardous Areas

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 way spool valves electromagnetic actuated, indirectly controlled G1/4, 1/4 NPT, G1/2, 1/2 NPT 70 Inline 3/, / & /3 way spool valves electromagnetic actuated, indirectly controlled G/, / NPT, G/, / NPT Main application: single and double operated actuators TÜV-approval based on type examination

More information

Zener Barriers Bulletin 937Z

Zener Barriers Bulletin 937Z Technical Data Zener Barriers Bulletin 937Z Topic Page Introduction 2 Mounting 2 Housing 3 Operating Principle 3 Specifications 6 Introduction Allen-Bradley Zener barriers are a cost-effective solution

More information

Inductive sensor with analog output BI15-M30-LI-EXI

Inductive sensor with analog output BI15-M30-LI-EXI ATEX category II 1 G, Ex-zone 0 ATEX category II 2 D, Ex-zone 21 Threaded barrel, M30 x 1.5 Chrome-plated brass Analog+ Extended operating range 2-wire, 14 30 VDC Analog output 4 20 ma Cable connection

More information

PI-EX-ME-2NAM/COC-120VAC

PI-EX-ME-2NAM/COC-120VAC PI-EX-ME-NAM/COC-0VAC Ex-i NAMUR Isolation Amplifier, With Intrinsically Safe Input and Relay Output, PDT, Two-Channel, 0 V AC Supply INTERFACE Data Sheet 0944_00_en PHOENIX CONTACT - 0/008 Description

More information

SMARTLINE RM76 Supplementary instructions

SMARTLINE RM76 Supplementary instructions SMARTLINE RM76 Supplementary instructions 2-wire / Guided Radar (TDR) Level Meter Supplementary Instructions for ATEX applications CONTENTS SMARTLINE RM76 1 General safety information 5 1.1 Scope of the

More information

BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12

BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12 BA304D Intrinsically safe loop-powered 3½ digit field mounting indicator issue 12 Issue: 12 25 th September 2008 2 CONTENTS 1. Description 2. Operation 3. Intrinsic Safety Certification 3.1 ATEX certificate

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 70013111 (064969_0_000) Issued to: MSA - The Safety Company 1000 Cranberry Woods Dr Cranberry Township, Pennsylvania 16066-5296 USA Attention: Stephen Kancel The

More information

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication

Series 3731 Electropneumatic Ex d Positioner Type with FOUNDATION TM Fieldbus communication Series 3731 Electropneumatic Ex d Positioner Type 3731-5 with FOUNDATION TM Fieldbus communication Application Positioner for attachment to pneumatic control valves Travel: 3.6 to 200 mm Opening angle:

More information

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC

Signal processor MS96 for flow sensors MS96-11EX0-R/230VAC MS96-11EX0-R/230VAC ATEX category II (1) G, Ex Zone 0 ATEX category II (1) D, Ex Zone 20 single-channel signal processor MS96 for connection of an intrinsically safe flow control sensor in zone 0 adjustment

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Automatic end position adjustment With ATEX II cat. G/D and cat. D/G

More information

General Specifications

General Specifications General Specifications EJA-E Series FOUNDATION TM Fieldbus Communication FOUNDATION fieldbus is the digital communication line for the field instruments, whose signal is internationally standardized by

More information

Digital electropneumatic Positioner SideControl

Digital electropneumatic Positioner SideControl Digital electropneumatic Positioner SideControl Type 8791 BASIC can be combined with Compact and robust design Easy to start using tune function Dynamic positioning system with no air consumption in controlled

More information

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication

Data Sheet T 8493 EN. Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Data Sheet T 8493 EN Series 3793 TROVIS 3793 Electropneumatic Positioner with HART communication Application Single-acting or double-acting positioner for attachment to pneumatic control valves. Self-calibrating,

More information

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505

Operating Instructions. Intrinsically Safe Isolation Relay for Switches Model: REL manual_rel-6_0505 Operating Instructions Intrinsically Safe Isolation Relay for Switches Model: REL-6003 manual_rel-6_0505 1. Contents 1. Contents...2 2. Note...3 3. Instrument Inspection...3 4. Regulation Use...3 5. Operating

More information

SideControl Positioner

SideControl Positioner SideControl Positioner Electropneumatic positioner for pneumatically actuated process valves II (1) 2 G EEx ia IIC T6 approval can be combined with... Type 2712 Globe valve Globe valve acc. to NAMUR/IEC

More information

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner

Data Sheet T 8394 EN. Series 3725 Type 3725 Electropneumatic Positioner Data Sheet T 8394 EN Series 3725 Type 3725 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to

More information

Digital Output Module 8-Channel Version for Zone 2 Series 9475/

Digital Output Module 8-Channel Version for Zone 2 Series 9475/ > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Line fault monitoring per channel > Diagnostics based on NE107 > Module can be replaced in

More information

F101, F102, F104. Relcom Installation Instructions. Fieldbus Power Supply F101-PS

F101, F102, F104. Relcom  Installation Instructions. Fieldbus Power Supply F101-PS F101, F102, F104 Fieldbus Power Supply F101-PS Installation Instructions Relcom www.mtl-fieldbus.com CONTENTS PAGE 1 OVERVIEW 2 2 DESCRIPTION 2 3 COMPONENTS AND ACCESSORIES 2 4 MECHANICAL 3 4.1 Mounting

More information

Digital Output Module 8-Channel Version for Zone 1 Series 9475/

Digital Output Module 8-Channel Version for Zone 1 Series 9475/ www.stahl.de > 8-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

Rotork Fairchild PAX1 Linear Actuator User s Manual

Rotork Fairchild PAX1 Linear Actuator User s Manual Rotork Fairchild PAX1 Linear Actuator User s Manual Product Overview The PAX1 is a flexible low voltage DC powered linear actuator featuring a 5 mm maximum thrust rod stroke moving at speeds up to 0 mm/min

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ia > For Ex i solenoid valves and display elements > Additional Ex i control input for "Plant STOP" (acc. IEC61508 up to SIL2) >

More information

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT

97105 Inline 3/2, 5/2 & 5/3 spool valves electromagnetic actuated, indirectly controlled G 1/4, 1/4 NPT, G 1/2, 1/2 NPT 705 Inline 3/, 5/ & 5/3 spool valves electromagnetic actuated, indirectly controlled G /, / NPT, G /, / NPT For single and double operated actuators Valves for safety systems up to SIL (IEC 6508) Crossover-free

More information

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5

TFR5. Room or outdoor temperature sensor. Operating instructions for temperature sensor. English page 1...5 EN/2018-03-14 Design and specifications subject to change without notice Operating instructions for temperature sensor English page 1...5 Field of application CombiTemp is a temperature sensor, based on

More information

Startup instructions. AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC)

Startup instructions. AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC) Startup instructions AutoConfiguration Adapter ACA21-USB (EEC) ACA22-USB (EEC) ACA21-M12 (EEC) ACA22-M12 (EEC) Release 02 04/2014 Technical Support https://hirschmann-support.belden.eu.com The naming of

More information

Certificate of Compliance

Certificate of Compliance Certificate of Compliance Certificate: 1367759 (LR 18656) Master Contract: 158394 Issued to: Honeywell Inc. 512 Virginia Dr Fort Washington, PA 19034-3260 USA Attention: Edward A. Child The products listed

More information

Positioners SIPART PS2. Technical description. 6/12 Siemens FI Benefits. Overview

Positioners SIPART PS2. Technical description. 6/12 Siemens FI Benefits. Overview Positioners Siemens AG 2010 Technical description Overview Electropneumatic positioner in the Makrolon enclosure Ex d electropneumatic positioner in flameproof aluminium enclosure (Ex d) in stainless steel

More information

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div.

Termination Board FC-GPCS-SAI16-PF. Features. Assembly. Function. Connection. SAI-1620m HART 24 V DC (I), 24 V DC (II) Fault. Zone 0, 1, 2 Div. Features Assembly System board for Honeywell Safety Manager For 6-channel AI card SAI-60m For 6 modules Recommended module: HiC05 (AI) 4 V DC supply Hazardous area: pluggable screw terminals, blue Non-hazardous

More information

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06

YT-870 / 875 Series. Rotork YTC Limited VERSION 1.06 PRODUCT MANUAL Rotork YTC Limited VERSION 1.06 Contents 1 Introduction... 3 1.1 General Information for the users... 3 1.2 Manufacturer Warranty... 3 1.3 Explosion Proof Warning... 4 2 Product Description...

More information

Digital Output Module 4-Channel Version for Zone 1 Series 9475/

Digital Output Module 4-Channel Version for Zone 1 Series 9475/ www.stahl.de > 4-channel digital output > Intrinsically safe outputs Ex ib > Suitable for Ex i hydraulic valves and solenoid valves > Additional Ex i control input for (in accordance with IEC 61508 through

More information

Type i2p-100 Electro-Pneumatic Transducer

Type i2p-100 Electro-Pneumatic Transducer Product Bulletin i2p-100 Transducer Type i2p-100 Electro-Pneumatic Transducer The Type i2p-100 electro-pneumatic transducer, shown in figure 1, uses a patented converter module that converts a milliampere

More information

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function PNP NO/NC Rated operating distance s n 5 mm Model Number Features 5 mm flush ATEX-approval for zone and zone Accessories BF 8 Mounting flange, 8 mm EXG-8 Quick mounting bracket with dead stop Technical Data specifications Switching element function

More information

Emergency power supply NV2.1-12iaE

Emergency power supply NV2.1-12iaE Ordering Data Designation Type Item no. 372 100 04 AX Supply of consumers even in case of failure or shutdown of the input / charging current circuit NiCd as energy store Intrinsically safe input voltage

More information

Smart Wireless THUM Adapter

Smart Wireless THUM Adapter Quick Installation Guide Smart Wireless THUM Adapter Smart Wireless THUM Adapter Start Wireless Considerations Step 1: Physical Installation Step 2: Verify Operation Reference Information Product Certifications

More information

Technical Information RIA15

Technical Information RIA15 T004K/09/EN/04.4 759844 Products Solutions Services Technical nformation RA5 Loop-powered 4 to 0 ma with optional HART communication Compact with very low voltage drop for universal use to display 4 to

More information

M E M O R A N D U M I.S.

M E M O R A N D U M I.S. Physikalisch-Technische Bundesanstalt Department 3.6 " Intrinsic safety and Safety of Systems" 38023 Braunschweig Germany P.O. Box 33 45 Tel. ++49 531 592-3630 Fax ++49 531 592-3605 M E M O R A N D U M

More information

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0.

LMP 308. Separable Stainless Steel Probe. Stainless Steel Sensor. accuracy according to IEC 60770: standard: 0.35 % FSO option: 0.25 % FSO / 0. LMP 08 Separable Stainless Steel Sensor accuracy according to IEC 60770: standard: 0.5 % FSO option: 0.25 % FSO / 0. % FSO Nominal pressure from 0... mh 2 O up to 0... 250 mh 2 O Output signals 2-wire:

More information

Pneumatic Control/Feedback

Pneumatic Control/Feedback 897 /Feedback Type 897 can be combined with... Compact design Integrated pilot valve with manual override Internal control air routing Bright LED position indicator Automatic end position adjustment Type

More information

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S

D1093S INSTRUCTION MANUAL. D SIL 3 Relay Output Module with Line and Load diagnostics. DIN-Rail Model D1093S D109S INSTRUCTION MANUAL SIL Relay Output Module with Line and diagnostics DINRail Model D109S D109 SIL Relay Output Module with Line and diagnostics ISM0096 SIL Applications For Safety Related System

More information

Tutorial: Characteristics & Requirements of Physical Networks in the Process Industry

Tutorial: Characteristics & Requirements of Physical Networks in the Process Industry Tutorial: Characteristics & Requirements of Physical Networks in the Process Industry IEEE802.3cg 10 Mb/s Single Twisted Pair Ethernet Task Force Brian Franchuk Martin Zielinski Introduction 2 Pertinent

More information

Digital electropneumatic positioner SideControl

Digital electropneumatic positioner SideControl Digital electropneumatic positioner Type 879 can be combined with Compact and robust design Easy to start using tune function Integrated diagnostic functions for valve monitoring (optional) Dynamic positioning

More information

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97

Inductive sensor Dual sensors with extended temperature range NI4-DSU35TC-2Y1X2/S97 ATEX category II 2 G, Ex zone 1 ATEX category II 1 D, Ex-zone 20 for temperatures up to -25 C SIL2 acc. to IEC 61508 Rectangular, housing DSU35 Plastic, PP-GF30-VO Two outputs for monitoring the position

More information

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI

Inductive Angle Sensor With Analog Output RI360P1-DSU35TC-ELI-EXI ATEX category II 2 G, Ex Zone 1 ATEX category II 2 D, Ex Zone 21 Rectangular, housing DSU35 Plastic, PP-GF30-VO Detecting angular positions of 0 to 360 P1-Ri-DSU35 positioning element included in delivery

More information

Introduction. Additional Information. Digital Positioner for the positioning of pneumatically controlled final control elements.

Introduction. Additional Information. Digital Positioner for the positioning of pneumatically controlled final control elements. ABB MEASUREMENT & ANALYTICS OPERATING INSTRUCTION PositionMaster EDP300 Digital Positioner Digital Positioner for the positioning of pneumatically controlled final control elements. EDP300 Introduction

More information

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div.

Termination Board. HiCTB08-SCT-44C-SC-RA. Features. Assembly. Function. Connection. 24 V DC (I), 24 V DC (II), Fault. Zone 0, 1, 2 Div. Termination Board HiCTB08-SCT-C-SC-RA Features Assembly For 8 modules V DC supply Supported signal types: DI/DO/AI/TI/AO Hazardous area: screw terminals, blue Safe area: screw terminals, black Function

More information

SITRANS TH400 SITRANS T. Temperature transmitter SITRANS TH400. Introduction 1. General safety notes. Description 3. Assembly. Connecting.

SITRANS TH400 SITRANS T. Temperature transmitter SITRANS TH400. Introduction 1. General safety notes. Description 3. Assembly. Connecting. Introduction 1 General safety notes 2 SITRANS T Temperature transmitter Operating Instructions Description 3 Assembly 4 Connecting 5 Operation 6 Commissioning 7 Functions 8 Service and maintenance 9 Technical

More information

High-precision valve control using intelligent positioners. sipart

High-precision valve control using intelligent positioners. sipart High-precision valve control using intelligent positioners sipart The SIPART PS2 electropneumatic positioner is number 1 in its field by a very wide margin. Our past experience gathered from 15 years in

More information

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001

PROCESS AUTOMATION. MANUAL Z-System. Zener Barriers ISO9001 PROCESS AUTOMATION MANUAL Z-System Zener Barriers ISO9001 With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and

More information

T EN TROVIS Electropneumatic Positioner

T EN TROVIS Electropneumatic Positioner T 8484-1 EN TROVIS 3730-1 Electropneumatic Positioner Application Single-acting positioner for attachment to pneumatic globe and rotary valves. Self-calibrating, automatic adaptation to valve and actuator.

More information

IECEx Certificate of Conformity

IECEx Certificate of Conformity IECEx Certificate of Conformity INTERNATIONAL ELECTROTECHNICAL COMMISSION IEC Certification Scheme for Explosive Atmospheres for rules and details of the IECEx Scheme visit www.iecex.com Certificate No.:

More information

BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3

BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting Fieldbus Display issue 3 TR Automatyka Sp. z o. o. Tel. (+48 022) 886 10 16 www.trautomatyka.pl ul. Lechicka 14 ; 02-156 Warszawa Fax. (+48 022) 846 50 37 biuro@trautomatyka.pl BA488CF-P PROFIBUS PA Intrinsically safe Panel mounting

More information

The High Power Trunk Alternative to FISCO and FNICO

The High Power Trunk Alternative to FISCO and FNICO The High Power Trunk Alternative to FISCO and FNICO Bernd Schuessler, Business Development Manager Pepperl+Fuchs Twinsburg, OH 330-486-0002 www.fieldconnex.info End users throughout the Fieldbus world

More information