Installation Guide Versatile Access Power and Integration Enclosures

Size: px
Start display at page:

Download "Installation Guide Versatile Access Power and Integration Enclosures"

Transcription

1 Rev Installation Guide Versatile Access Power and Integration Enclosures Trove1C1 Trove2CV2 - Trove1 enclosure with - Trove2 enclosure with /CDVI backplane (TC1) /CDVI backplane (TCV2) TC1 TCV2 - /CDVI backplane only - /CDVI backplane only Overview: Trove1C1 and Trove2CV2 accommodate various combinations of CDVI boards with or without power supplies and accessories for access systems. Specifications: 19 Gauge grey enclosure with ample knockouts for convenient access. Trove1C1 - Trove1 enclosure with TC1 /CDVI backplane. Includes: tamper switch, cam lock, lock nuts and mounting hardware. Enclosure Dimensions (H x W x D): 18 x 14.5 x (457mm x 368mm x 118mm) TC1 - TC1 /CDVI backplane. 19 Gauge backplane. Includes mounting hardware. Dimensions (H x W x D): x 12.5 x ( mm x 317.5mm x 7.9mm) TC1 Backplane accommodates a combination of the following: One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eflow4nb, eflow6nb, eflow102nb or eflow104nb. One (1) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6. Four (4) A22 modules. Trove2CV2 - Trove2 enclosure with TCV2 /CDVI backplane. Includes: tamper switch, cam lock, lock nuts and mounting hardware. Enclosure Dimensions (H x W x D): x x 6.5 (692.15mm x mm x 165.1mm) TCV2 - TCV2 /CDVI backplane. 19 Gauge backplane. Includes mounting hardware. Dimensions (H x W x D): x x ( mm x mm x 7.9mm) TCV2 Backplane accommodates a combination of the following: Two (2) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eflow4nb, eflow6nb, eflow102nb or eflow104nb. One (1) ACM8(CB), or two (2) MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6. Five (5) A22 modules. Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 1 -

2 Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. 2. Trove1C1 (Fig. 5, pg. 5) Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws. Trove2CV2 (Fig. 9, pg. 8) Mark and predrill holes on the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws. 3. Mount UL Listed tamper switch (Included) (Ademco model 112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2 from the right side (Fig. 1, pg. 1). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. 4. Mount /CDVI modules to TC1 or TCV2 backplane, refer to pages 3 and 6. Mounting Hardware: Plastic Standoff Metal Standoff 3/8 Pan Head Screw Honeywell model # 112 Tamper Switch or equivalent (provided) Enclosure to Access Control Panel or U.L. Listed Reporting Device Fig. 1 Edge of Enclosure Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI

3 TC1: Configuration of Power Supply and/or Sub-Assembly Boards and CDVI Modules 1. Fasten standoffs (provided) to pems that match the hole pattern for Power Supply/Chargers or Sub-Assembly boards (Fig. 3, pg. 3). Fasten metal standoffs in the correct locations to provide proper grounding, see below (Fig. 3, pg. 3). 2. Mount boards to standoffs utilizing 5/16 pan head screws (provided) (Fig. 3, pg. 3). 3. Mount appropriate CDVI A22 modules into the correct positions (Fig. 3, pg. 3). by postioning standoffs over appropriate holes on the backplane and depress down on board to secure standoff to the backplane (Fig. 2, pg. 3). Note: CDVI A22 modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 3 below. 4. Fasten TC1 backplane to Trove1 enclosure utilizing pan head screws (provided). Fig. 3 - Trove1C1/TC1 Configurations Plastic Stand Off pre-mounted into CDVI Atrium modules Insert into TC1/TCV2 backplane Fig. 2 Metal Standoff Placement Power Supply Sub- Assembly Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 3 -

4 Fig. 4 TC1 Dimensions 0.5 (12.7mm) 12.5 (321.31mm) 8.15 (207.01mm) (422.9mm) (397.5mm) 6.25 (158.75mm) 0.5 (12.7mm) Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI

5 Fig. 5 Trove1C1 Enclosure Dimensions (H x W x D): 18 x 14.5 x (457mm x 368mm x 118mm) 7.25 (184.15mm) 14.5 (321.31mm) 1.45 (36.83mm) (49.483mm) 4.5 (114.3mm) 13.0 (330.2mm) 1.5 (38.09mm) (14.98mm) 1.5 (38.09mm) (14.52mm) 8.5 (215.9mm) 8.5 (215.9mm) 18.0 (457.2mm) 6.5 (165.1mm) 6.5 (165.1mm) (15.27mm) (27.83mm) 4.5 (114.3mm) 4.5 (114.3mm) 2.75 (69.85mm) (28.32mm) (34.59mm) Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 5 -

6 TCV2: Configuration of Power Supply and/or Sub-Assembly Boards and CDVI Modules 1. Fasten standoffs (provided) to pems that match the hole pattern for Power Supply/Chargers or Sub-Assembly boards (Fig. 7, pg. 6). Fasten metal standoffs in the correct locations to provide proper grounding, see below (Fig. 7, pg. 6). Note: sub-assembly position can accommodate either one (1) ACM8/ ACM8CB or two (2) PD4UL/PD4ULCB, PD8UL/PD8ULCB or MOM5. 2. Mount boards to standoffs utilizing 5/16 pan head screws (provided) (Fig. 7, pg. 6). 3. Mount appropriate CDVI A22 modules into the correct positions (Fig. 7, pg. 6). by postioning standoffs over appropriate holes on the backplane and depress down on board to secure standoff to the backplane (Fig. 6, pg. 6). Note: CDVI A22 modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 7 below. 4. Fasten TCV2 backplane to Trove2 enclosure utilizing pan head screws (provided). Fig. 7 Plastic Stand Off pre-mounted into CDVI Atrium modules Insert into TC1/TCV2 backplane Fig. 6 Power Supply Metal Standoff Placement Power Supply or Sub-Assembly Metal Standoff Placement Sub-Assembly Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI

7 Fig (190.5mm) TCV2 Dimensions 19.4 (492.76mm) 7.5 (190.5mm) (633.73mm) ( 3.96mm) 25.4 (645.16mm) (320.55mm) (320.55mm) (215.77mm) (412.62mm) 1.0 (25.4mm) 0.45 (11.43mm) 7.5 (190.5mm) 1.0 (25.4mm) 7.5 (190.5mm) 9.2 Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 7 -

8 Fig. 9 Trove2CV2 Enclosure Dimensions (H x W x D): x x 6.5 (692.15mm x mm x 165.1mm) 5.25 (133.35mm) 3.50 (88.9mm) (546.1mm) 3.50 (88.9mm) 5.25 (133.35mm) (14.29mm) (61.34mm) 1.77 (44.96mm) (17.399mm) Knockouts (28.32mm) (22.479mm) 6.25 (158.75mm) 6.25 (158.75mm) 0.85 (21.59mm) 1.5 (38.1mm) (502.92mm) 6.75 (171.45mm) G (685.8mm) 8.25 (209.54mm) 8.00 (203.2mm) 0.85 (21.59mm) 1.00 (25.4mm) 5.25 (133.35mm) 7.00 (177.79mm) 5.25 (133.35mm) is not responsible for any typographical errors. Product specifications are subject to change without notice th Street, Brooklyn New York USA, , fax: website: info@altronix.com. Made in USA. IITrove1C1/Trove2CV2 - Rev F22P MEMBER Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI

Installation Guide. Versatile Access Power and Integration Enclosures. Trove2M2 - Trove2 enclosure with Altronix/Mercury backplane

Installation Guide. Versatile Access Power and Integration Enclosures. Trove2M2 - Trove2 enclosure with Altronix/Mercury backplane Versatile Access Power and Integration Enclosures Installation Guide Models Include: Trove2M2 - Trove2 enclosure with / backplane TM2 - / backplane only Trove2V2 - Trove2 enclosure with / backplane TV2

More information

Access & Power Integration Solutions

Access & Power Integration Solutions ccess & Power Integration Solutions Installation Guide for models: T2MK3F4 - (1) eflow6n - Power Supply/Charger - (1) CM4 - Fused ccess Power Controller T2MK3F4Q - (1) eflow6n - Power Supply/Charger -

More information

Expandable Power Systems

Expandable Power Systems Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.

More information

DC Outdoor Power Supply/Chargers

DC Outdoor Power Supply/Chargers DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC

More information

718.567.8181 info@altronix.com 1 Trove access and power integration solutions easily combine Altronix power and accessories with access controllers available from the industry s leading manufacturers.

More information

3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide Embedded 3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide Models include: NetWaySP3WP - Includes Fiber Optic SFP 1G, 3-port PoE+ switch and power supply. - NEMA4/4X, IP66 rated Outdoor

More information

8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual

8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual Embedded 8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual NetWaySP8WP - Includes Fiber Optic SFP 1G Link, 8-port PoE switch and power supply. - NEMA4/4X, IP66 rated Outdoor enclosure.

More information

4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide

4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide Embedded 4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide Models include: NetWaySP4WP - Includes Fiber Optic SFP 1G Link, 4-port PoE+ switch and power supply. - NEMA4/4X, IP66 rated

More information

AL168 Series Multi-Output Power Supplies

AL168 Series Multi-Output Power Supplies AL168 Series Multi- Power Supplies Installation Guide Models Include: AL168CB - 16VAC @ 6A (100VA) or 18VAC @ 5.5A (100VA). AL168175CB - 16VAC @ 10A (175VA). AL168300CB - 16VAC @ 18A (350VA) or 18VAC @

More information

Active UTP Transceiver Hub with Integral Isolated Camera Power

Active UTP Transceiver Hub with Integral Isolated Camera Power Active UTP Transceiver Hub with Integral Isolated Installation Guide HubWayEX16SP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Rev. 011810 More than just power. TM

More information

Enclosures AE1/AE3. Installation Guide

Enclosures AE1/AE3. Installation Guide Enclosures AE1/AE3 en Installation Guide Enclosures Safety en 3 1 Safety Notice! Do not flush mount! Regulatory agency requirements prohibit flush mounting the enclosures.! Caution! Ensure the enclosure

More information

NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC

NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC Installation Guide NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC Rev. 112713 Overview: Altroni NetWay1DWP Outdoor Single Port Midspan

More information

long range ethernet Extend Ethernet range 5x the distance - without repeaters. Long Range Ethernet Adapters Features:

long range ethernet Extend Ethernet range 5x the distance - without repeaters. Long Range Ethernet Adapters Features: FEATURED PRODUCTS SECURITY / ACCESS / FIRE / SURVEILLANCE long range ethernet 2 Extend Ethernet range 5x the distance - without repeaters. - Deploy IP cameras/edge devices up to 500m over CAT5e/6. - Passes

More information

Rack Mount Power Supplies

Rack Mount Power Supplies Rack Mount Power Supplies Installation Guide Models Include: VertiLine33D - 12VDC @ 8A - Sixteen (16) PTC protected outputs VertiLine33TD - 12VDC @ 16A - Sixteen (16) PTC protected outputs VertiLine63D

More information

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8D HubWay16D - Eight (8) Channels - Sixteen (16) Channels HubWay82D HubWay162D - HubWay8 w/eight (8) HubWayAv - HubWay16

More information

Transceiver Hub with Integral Camera Power

Transceiver Hub with Integral Camera Power Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8CD HubWay16CD - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver Hub

More information

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide Active UTP Transceiver Hub with Integral Installation Guide Models Include: HubWayLD8CDS - UL Listed eight (8) Channel Active UTP Transceiver Hub with Integral HubWayLD82CDS - UL Listed eight (8) Channel

More information

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Passive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide Passive UTP Transceiver Hub with Integral Isolated Installation Guide Models Include: HubWay8Di HubWay16Di - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver

More information

Active UTP Transceiver Hub with Integral Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Camera Power Installation Guide Active UTP Transceiver Hub with Integral Installation Guide Models Include: HubWayLD8D HubWayLD16D - Eight (8) Channels - Sixteen (16) Channels HubWayLD82D HubWayLD162D - HubWayLD8D w/eight (8) HubWayAv

More information

Passive UTP Transceiver Hub Installation Guide

Passive UTP Transceiver Hub Installation Guide Video Data Passive UTP Transceiver Hub Installation Guide Models Include: - Sixteen (16) Camera Channels Rev. 121710 More than just power. TM Overview: Altronix Passive UTP Transceiver Hub transmits UTP

More information

Installation and User Guide

Installation and User Guide Installation and User Guide VADDIO DOMEVIEW HD INDOOR PENDANT MOUNT DOME ENCLOSURE FOR THE VADDIO HD-20, HD-19 AND HD-18 PTZ CAMERAS Part Number: 998-9100-200 2011 Vaddio - All Rights Reserved DomeVIEW

More information

ebridge200b - Managed Two Port Transceiver Board

ebridge200b - Managed Two Port Transceiver Board PLUS ebridge200b - Managed Two Pt Transceiver Board Installation Guide Rev. 049207 Overview: ebridge200b long range Ethernet transceiver/media converter transmits data and power over Coax CAT5 cable over

More information

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide

Active UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide Active UTP Transceiver Hub with Integral Isolated Installation Guide Models Include: HubWayLD8Di HubWayLD16Di - UL Listed eight (8) Channel Active UTP - UL Listed sixteen (16) Channel Active UTP Transceiver

More information

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)

User s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1) User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com

More information

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)

Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only) Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only) **TURN POWER OFF OF MACHINE BEFORE INSTALLATION** READ ALL INSTRUCTIONS BEFORE STARTING INSTALLATION Retrofit Kit Contents PART NAME

More information

Universal Desktop and Monitor Stand

Universal Desktop and Monitor Stand Universal Desktop and Monitor Stand Installation Instructions Kit P/N: 114-6013 Kit Contents Kit Contents: (1) Stand Assembly (1) VESA Monitor Bracket (1) Bottom Bracket (1) Top Bracket (1) Clamp Bracket

More information

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version

USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version 2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS 19 20 21 01 07 22 23 13 10 12 08 17 18 11 02 14 15 04 03 16 WELCOME PARTS LIST Thank you for purchasing this HealthPoint Technology Cabinet from Humanscale! Before you begin installing

More information

Installation Guide. Rev

Installation Guide. Rev Installation Guide Rev. 120913 NetWay4ES - 4-Port Managed /+ Switch NetWay4ESK - Kit includes: NetWay4ES and NetWay1E (84W Midspan Injector, 115VAC input) NetWay4ESKV - Kit includes: NetWay4ES and NetWay1EV

More information

Vertiv VR Rack 1.0 GENERAL

Vertiv VR Rack 1.0 GENERAL 1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic

More information

EWS660AP. Quick Installation Guide

EWS660AP. Quick Installation Guide Package contents - Managed indoor access point - Power adapter - RJ-45 Ethernet cable - Mounting bracket - Mounting kit - T-Rail mounting kit IP Adress configuration Step 1: Once your computer is on, ensure

More information

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)

INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY L DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY L SYSTEMS) Doc. 6001025 Rev B INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS) Rev. B Doc. 6001025 Page 1 of 13 IMPORTANT NOTICE This document covers

More information

New IP & Power Solutions. for 2018

New IP & Power Solutions. for 2018 New IP & Power Solutions for 2018 long range ethernet 2 Extend Ethernet range 5x the distance - without repeaters. - Deploy IP cameras/edge devices up to 500m over CAT5e/6. - Passes PoE/PoE+ generated

More information

7403 K321. Display Wall Mount. Kit Instructions. Issue A

7403 K321. Display Wall Mount. Kit Instructions. Issue A 7403 K321 Display Wall Mount Kit Instructions Issue A ii Revision Record Issue Date Remarks A Nov 2008 First issue 1 Introduction This kit is used in to secure a 7403 Display Head on a vertical surface.

More information

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES 1. Turn off and unplug the game. COPYRIGHT 2007 MERIT ENTERTAINMENT 2. Unlock and open the CPU section. Ion evo/evo Wallette/Elite Edge ECS Motherboard Removal 3. Remove the 3 screws securing the I/O board

More information

AM-516. Adaptor Ring. User s Manual. Complies with FD8162 fixed dome camera. Rev IP Surveillance

AM-516. Adaptor Ring. User s Manual. Complies with FD8162 fixed dome camera. Rev IP Surveillance AM-516 Adaptor Ring User s Manual Complies with FD8162 fixed dome camera Rev. 1.0 IP Surveillance I Overview AM-516 Adaptor Ring Adaptor ring for FD8162 fixed dome camera. The supported installation types

More information

Assembly Instructions for #5630 Medication PalWOW

Assembly Instructions for #5630 Medication PalWOW Assembly Instructions for #5630 Medication PalWOW Before assembling, please familiarize yourself with all the parts and check to make sure you have all the parts as listed below. A B A & B - The box in

More information

BL-FLOWSTN-P FlowStation Module Installation Guide

BL-FLOWSTN-P FlowStation Module Installation Guide Introduction Baseline s FlowStation is available as an add-on module that is installed inside a pedestal enclosure with a BaseStation 3200 irrigation controller. The FlowStation module comes with a 5-port

More information

Firebox X Edge e-series De-Manufacturing Instructions

Firebox X Edge e-series De-Manufacturing Instructions Firebox X Edge e-series De-Manufacturing Instructions Document Number: 480-2530-001 WatchGuard Technologies. Doc #480-2530-001 Rev. A Page 1 of 9 1.0 Purpose This instruction defines the de-manufacturing

More information

Installing a Power over Ethernet injector

Installing a Power over Ethernet injector Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart

More information

Network Power Distribution Module

Network Power Distribution Module Please be sure to visit altronix.com for latest firmware and installation instructions Network Power Distribution Module Installation and Programming Manual Models include: LINQ8PD - Network Power Distribution

More information

INSTRUCTION BULLETIN

INSTRUCTION BULLETIN INSTRUCTION BULLETIN No. 9008755 Machine: T16 Published: 03-2011 Rev. 00 NOTE: DO NOT DISCARD the Parts List from the Instruction Bulletin. Place the Parts List in the appropriate place in the machine

More information

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions

USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions 2008-2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla St. Chatsworth, CA 91311 www.calmotion.com Introduction This

More information

HomeWorks Remote Power Feed-Through Panels

HomeWorks Remote Power Feed-Through Panels power feed-through panels are available in two different sizes, each of which may be either surface-mounted or recess-mounted, in an electrical closet or other equipment room. The number of remote power

More information

IS-DM220/IR/HB IS-DM220

IS-DM220/IR/HB IS-DM220 IS-DM220/IR/HB IS-DM220 Installation Guide Indoor/Outdoor Ver. 1.2 00P6NX223ZXSEA2 Table of Contents 1. Indoor Camera Installation... 3 1.1 Hard Ceiling... 3 1.2 In-Ceiling (T-Bar) Mounting... 13 1.3 4S

More information

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security

modular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,

More information

PoE Managed Midspan Solution for Standard Network Infrastructure

PoE Managed Midspan Solution for Standard Network Infrastructure Power over the Ethernet PoE Managed Midspan Solution for Standard Network Infrastructure Installation Guide Models Include: NetWay8M NetWay16M - Eight (8) Port PoE Midspan Injector - Sixteen (16) Port

More information

Terminal Equipment Controller Enclosure

Terminal Equipment Controller Enclosure Document No. 550-196 Terminal Equipment Controller Enclosure Product Description A Terminal Equipment Controller enclosure is a general-purpose metal cabinet with a removable cover that houses an electronic

More information

TruPortal Dual Door Interface Module Quick Reference

TruPortal Dual Door Interface Module Quick Reference TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers

More information

Installation Notes TII Model 341 Protector

Installation Notes TII Model 341 Protector Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow

More information

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:

Phase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin: Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss

More information

TDM To MiniMech conversion ProceDure

TDM To MiniMech conversion ProceDure TDM To MiniMech conversion ProceDure (Model 9100 ATM) TDN 07102-00079 Apr 1 2009 CorporATe HeAdquArTers: 522 E. Railroad Street Long Beach, MS 39560 PHONE: (228) 868-1317 FAX: (228) 868-0437 COPYRIGHT

More information

TELEPHONE FLUSH WALL PLATE

TELEPHONE FLUSH WALL PLATE TELEPHONE FLUSH WALL PLATE Single Jack Modular flush wall jack assembly allows flush-mounted connection of plug-ended modular line cords. Ideal for initial installation or conversion from existing wall

More information

ASSEMBLY AND ADJUSTMENT

ASSEMBLY AND ADJUSTMENT EDGE-WALL MONITOR ARM EDGE-WALL Rev A 2/17 Model EDGE-WALL-SLV ASSEMBLY AND ADJUSTMENT EDGE-WALL MONITOR ARM PLEASE REVIEW these instructions before beginning the installation. Check that all parts and

More information

How to Design Custom Enclosures for Motherboard-Based Systems

How to Design Custom Enclosures for Motherboard-Based Systems PROTOCASE TECHNICAL BULLETIN How to Design Custom Enclosures for Motherboard-Based Systems (covering ATX and Mini ITX form factors) Document Edition - 1 Last Updated: June 6 th,2011 Protocase, Inc. All

More information

TensionLitePlus Kiosk Design 4

TensionLitePlus Kiosk Design 4 TensionLitePlus Kiosk Design 4 TensionLite Plus Kiosks combine lightweight aluminum tube frames with state-of-the-art printed stretch zipper pillowcase fabric graphics to create funky and functional multimedia

More information

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions

SITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions Introduction 1 Installing/Mounting 2 SITRANS F Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel Hardware Installation Instructions 1/2010 A5E02518333A Revision 04 Legal information Warning notice

More information

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions

Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions 299-600-96 Rev. F MCG Surge Protection Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions Important Warranty Information: MCG surge protectors are designed to work at specific voltages

More information

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power.

Ethernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power. Ethernet/Network Communications Module Installation and Programming Manual LINQ2 - Two (2) Port Connectivity Module DOC#: LINQ2 Rev. 060514 More than just power. Overview: Altronix LINQ2 network module

More information

15P0097Q1 SINUS K - PENTA REMOTE MOUNTING THE KEYPAD MOUNTING GUIDE

15P0097Q1 SINUS K - PENTA REMOTE MOUNTING THE KEYPAD MOUNTING GUIDE 15P0097Q1 THE KEYPAD MOUNTING Upd. 12/01/06 R. 01 English This manual is integrant and essential to the product. Carefully read the instructions contained herein as they provide important hints for use

More information

Portable Staging User Guide

Portable Staging User Guide Portable Staging User Guide Components: ExpressDeck was designed for quick and easy assembly: set up is a snap, even if you have no experience! So let s take a moment to meet the components of your new

More information

Probably the fastest enclosure in the world

Probably the fastest enclosure in the world 95 9 enclosure system Probably the fastest enclosure in the world Sample configuration tools required no no tools required Vitaro can be assembled within less than 60 seconds. 00:00 00:0 00:08 00: 00:5

More information

PACSystems* RX3i IC695ACC650

PACSystems* RX3i IC695ACC650 September 2012 PACSystems* RX3i IC695ACC650 Series 90-70 to RX3i Conversion Rack The conversion rack provides a solution for converting an existing Series 90-70 system to PACSystems RX3i, minimizing outage

More information

TruPortal Output Expansion Board Quick Reference

TruPortal Output Expansion Board Quick Reference TruPortal Output Expansion Board Quick Reference en-us Packing List Introduction A TruPortal system can be expanded by adding an Input/Output Expansion module (TP-ADD-IO-BRD) that consists of: One TruPortal

More information

HAW-SIBU. Rack Installation Guide. Version 1.0.1

HAW-SIBU. Rack Installation Guide. Version 1.0.1 HAW-SIBU Rack Installation Guide Version 1.0.1 Mounting HAW-SIBU in a Rack The instructions here apply to the Sony HAW-SIBU. Cautions * Do not lift or move the HAW-SIBU unit by the handles on the ear brackets

More information

INSTALLATION INSTRUCTIONS: E KIT-EMV-INGENICO ICMP CRADLE-PAYPOINT E KIT-EMV-VERIFONE E355 CRADLE-PAYPOINT

INSTALLATION INSTRUCTIONS: E KIT-EMV-INGENICO ICMP CRADLE-PAYPOINT E KIT-EMV-VERIFONE E355 CRADLE-PAYPOINT E953516 KIT-EMV-INGENICO ICMP CRADLE-PAYPOINT E002639 KIT-EMV-VERIFONE E355 CRADLE-PAYPOINT 1 1- Add payment module to bracket (1) 2 Screws, X2 3- Add payment module/bracket (1) to bracket (2) with 2 screws

More information

DOCKING STATION SPECIFICATIONS

DOCKING STATION SPECIFICATIONS ONE PERSON STATION Power Outlets Data Jack Plate Mouse Brackets Front Covers Cable Holes Cable Holes Overview: The Docking Station distributes power, data, and laptop storage to each user. It also offers

More information

E1135C PDU and Pod Upgrade Procedure

E1135C PDU and Pod Upgrade Procedure E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support

More information

Series Amp Pad Mount Quick Connect Input and Output Power Panels

Series Amp Pad Mount Quick Connect Input and Output Power Panels Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.

More information

Formulate Accent - 04

Formulate Accent - 04 Formulate Accent - 04 FMLT-WL04 Formulate accents enhance the funtionality of any 10ft or 20ft backwall and add more real estate for messaging too! With monitor supports, literature pockets, shelves, tables,

More information

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116

XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116 XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116 XDBKITS5 Option Kit Installation Manual vacon 3 Installing the Bus / DB Terminal Option Kit Introduction The XDBKITS5 option kit is

More information

GV-EL124S Electric Strike

GV-EL124S Electric Strike GV-EL124S Electric Strike Featured with a built-in door status sensor, the GV-EL124S is a fail-secure electric strike, but it is field convertible from fail secure to fail safe. It can be mounted either

More information

Quick Start Guide. SEB-710 I/O Expansion board. Introduction

Quick Start Guide. SEB-710 I/O Expansion board. Introduction SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay

More information

Eaton LCD Lift Flat Panel Display System. Installation Guide

Eaton LCD Lift Flat Panel Display System. Installation Guide Eaton LCD Lift Flat Panel Display System Eaton LCD Lift Flat Panel Display System Installation Guide Copyright 2011 Eaton Corporation, Worcester, MA, USA. All rights reserved. Information in this document

More information

Assembly Instructions Triton Enclosure for Poseidon With Data Acquisition November, 2007 V0.9 DSC Document #

Assembly Instructions Triton Enclosure for Poseidon With Data Acquisition November, 2007 V0.9 DSC Document # Assembly Instructions Triton Enclosure for Poseidon With Data Acquisition November, 2007 V0.9 DSC Document #7521002 Diamond Systems Corp. (650) 810-2500 www.diamondsystems.com This document describes how

More information

Series Amp Quick Connect Input and Output Power Panels

Series Amp Quick Connect Input and Output Power Panels Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is

More information

PXC Compact Unitary Equipment Controller (UEC)

PXC Compact Unitary Equipment Controller (UEC) Document No. 553-169 PXC Compact Unitary Equipment Controller (UEC) Product Description The PXC Unitary Equipment Controller (UEC) is an MS/TP device that can be configured as a programmable, stand-alone

More information

FLEXBOX. Installation Guide

FLEXBOX. Installation Guide FLEXBOX Installation Guide FLEXBOX 1 Important Safety Instructions WEIGHT LIMIT MAXIMUM WEIGHT 50 LBS. THE STRUCTURE TO WHICH THE BOX IS MOUNTED (CEIL- ING, WALL, TABLE, POLE) MUST BE ABLE TO SUPPORT FIVE

More information

In-ceiling Housing. Installation Manual SHP-3701F

In-ceiling Housing. Installation Manual SHP-3701F In-ceiling Housing Installation Manual SHP-3701F TABLE OF CONTENTS Overview 3 What s Included 3 Installation Instructions 4 Installation (SCP-3430 Series) 4 Installation (SCP-3370/SNP-5200 SERIES) 9 Installation

More information

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2

TECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2 document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com

More information

EP/2 Installation Instructions

EP/2 Installation Instructions 1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in

More information

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES Hard Drive Removal IMPORTANT NOTE: If you are replacing a PATA hard drive with a SATA hard drive, please see PATA to SATA Hard Drive Conversion. Hard Drive Identification: To determine whether your hard

More information

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215

More information

PowerLogic High Density Metering System 1-Meter Enclosure

PowerLogic High Density Metering System 1-Meter Enclosure PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these

More information

Wireless Key fob, Key pad & Receiver Range

Wireless Key fob, Key pad & Receiver Range Wireless Key fob, Key pad & Receiver Range 4Ch Wireless Receiver 4x Voltage Free relay outputs (NO + NC) 100m Transmission range Multiple user codes 2 Channel wireless control Clear hinge up lid 12V DC

More information

TSMIU Wireless Bridge Installation and Configuration

TSMIU Wireless Bridge Installation and Configuration ation uration EPM Software must be 7.6.0.16 or greater and latest 750-E700B MIU code Hardware Installation 1. To install wireless bridge / bracket assembly and antenna, the MIU must be turned off and the

More information

Kit K Instructions. V8700 to Alpha Conversion Instructions

Kit K Instructions. V8700 to Alpha Conversion Instructions V8700 to Alpha Conversion Instructions Contents Contents Installation Instructions for Kit K-00927-0001 Before You Begin..................................................................................

More information

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES

ATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES Hard Drive Removal IMPORTANT NOTE: If you are replacing a PATA hard drive with a SATA hard drive, please see PATA to SATA Hard Drive Conversion. Hard Drive Identification: To determine whether your hard

More information

7" Touch Screen Display

7 Touch Screen Display 7" Touch Screen Display Installation Guide Contents Minimum Requirements...1 Select a Location...1 Initial Setup...2 Unboxing...2 Installation...3 Prepare the Panel...3 Install the Mounting Plate...3 Mount

More information

Warning Before Installation. Package Contents EN-1. Power off the Network Camera as soon as smoke or unusual odors are detected.

Warning Before Installation. Package Contents EN-1. Power off the Network Camera as soon as smoke or unusual odors are detected. English Warning Before Installation Power off the Network Camera as soon as smoke or unusual odors are detected. Do not place the Network Camera on unsteady surfaces. Do not insert sharp or tiny objects

More information

To Purchase This Item, Visit BMI Gaming (800)

To Purchase This Item, Visit BMI Gaming   (800) OWNERS AND SERVICE MANUAL INNOVATIVE CONCEPTS IN ENTERTAINMENT INC. 10123 MAIN STREET, CLARENCE, NY 14031 SERVICE: 1-716-759-0360 FAX: 1-716-759-0884 E-MAIL: service@icegame.com WEBSITE: www.icegame.com

More information

Thanks for shopping with Improvements! Chalet Standard Mailbox Item # (With 1 Line Plaque) Item # (With 2 Line Plaque)

Thanks for shopping with Improvements! Chalet Standard Mailbox Item # (With 1 Line Plaque) Item # (With 2 Line Plaque) Thanks for shopping with Improvements! Chalet Standard Mailbox Item #476200 (With 1 Line Plaque) Item #476242 (With 2 Line Plaque) To order, call 1-800-642-2112 West Chester, OH 45069 Made in China 1014

More information

PCLASS Integrated Paxton Access Power

PCLASS Integrated Paxton Access Power PCLASS Integrated Paxton Access Power All-in-one multi-door power solutions for Paxton Net2 and BLU controllers. Single and Dual Voltage, Standard and Networked. PCLASS Product Guide {jatabs type="content"

More information

Part Name/Description Part Number Quantity

Part Name/Description Part Number Quantity Part Name/Description Part Number Quantity Direct Command Kit 4100883 1 Installation Instructions 2006336 1 Hardware Kit Large Module 2001354-1 2 Cable Installation Kit 2000901-1 1 Quick Reference Card

More information

Tyler - Middle Mount For Bell 407, 206 & 206L Series Helicopters FAA STC # SH3246NM

Tyler - Middle Mount For Bell 407, 206 & 206L Series Helicopters FAA STC # SH3246NM MIDDLE MOUNT 407 / JET RANGER / LONG RANGER INSTALLATION MANUAL Tyler - Middle Mount For Bell 407, 206 & 206L Series Helicopters FAA STC # SH3246NM PLEASE RETURN THIS MANUAL WITH EQUIPMENT This manual

More information

Please read thoroughly before starting installation and check that kit contents are complete.

Please read thoroughly before starting installation and check that kit contents are complete. Chrysler/Dodge/Jeep Remote Add-On CD player for RA1, RA2, RA3, or RA4 radios (Kit # 5000-8750) 2013-current RAM truck and Viper; 2015-current Charger, Challenger, and 300; 2017 Pacifica Please read thoroughly

More information

FortiCam FD40 Mounting Guide

FortiCam FD40 Mounting Guide FortiCam FD40 Mounting Guide 1 FORTINET DOCUMENT LIBRARY http://docs.fortinet.com FORTINET VIDEO GUIDE http://video.fortinet.com FORTINET BLOG https://blog.fortinet.com CUSTOMER SERVICE & SUPPORT https://support.fortinet.com

More information

Portable Staging User Guide

Portable Staging User Guide Portable Staging User Guide Components: Putting together your smart stage system was designed to be simple enough for anyone to do easily. Nonetheless, let s take a moment for a little meet and greet A.)

More information

Use flat head screws for the out side of chassis and pan head screw for inside of chassis.

Use flat head screws for the out side of chassis and pan head screw for inside of chassis. These are instructions are guidelines in building a Storage Pod. 2-a Use flat head screws for the out side of chassis and pan head screw for inside of chassis. 1. Take the main chassis and check the chassis

More information

Ultima X5000 Rectangular Duct Mount Kit User Instructions

Ultima X5000 Rectangular Duct Mount Kit User Instructions Ultima X5000 Rectangular Duct Mount Kit User Instructions MSA Kit 10176947 - Ultima X5000 316 Stainless Steel Parts List / Instructions Rectangular Gasket (1) Rectangular Duct Mount Base Plate (1) Base

More information