Installation Guide Versatile Access Power and Integration Enclosures
|
|
- Jessie Parsons
- 5 years ago
- Views:
Transcription
1 Rev Installation Guide Versatile Access Power and Integration Enclosures Trove1C1 Trove2CV2 - Trove1 enclosure with - Trove2 enclosure with /CDVI backplane (TC1) /CDVI backplane (TCV2) TC1 TCV2 - /CDVI backplane only - /CDVI backplane only Overview: Trove1C1 and Trove2CV2 accommodate various combinations of CDVI boards with or without power supplies and accessories for access systems. Specifications: 19 Gauge grey enclosure with ample knockouts for convenient access. Trove1C1 - Trove1 enclosure with TC1 /CDVI backplane. Includes: tamper switch, cam lock, lock nuts and mounting hardware. Enclosure Dimensions (H x W x D): 18 x 14.5 x (457mm x 368mm x 118mm) TC1 - TC1 /CDVI backplane. 19 Gauge backplane. Includes mounting hardware. Dimensions (H x W x D): x 12.5 x ( mm x 317.5mm x 7.9mm) TC1 Backplane accommodates a combination of the following: One (1) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eflow4nb, eflow6nb, eflow102nb or eflow104nb. One (1) ACM4(CB), MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6. Four (4) A22 modules. Trove2CV2 - Trove2 enclosure with TCV2 /CDVI backplane. Includes: tamper switch, cam lock, lock nuts and mounting hardware. Enclosure Dimensions (H x W x D): x x 6.5 (692.15mm x mm x 165.1mm) TCV2 - TCV2 /CDVI backplane. 19 Gauge backplane. Includes mounting hardware. Dimensions (H x W x D): x x ( mm x mm x 7.9mm) TCV2 Backplane accommodates a combination of the following: Two (2) AL400ULXB2, AL600ULXB, AL1012ULXB, AL1024ULXB2, eflow4nb, eflow6nb, eflow102nb or eflow104nb. One (1) ACM8(CB), or two (2) MOM5, PD4UL(CB), PD8UL(CB), PDS8(CB), VR6. Five (5) A22 modules. Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 1 -
2 Installation Instructions: Wiring methods shall be in accordance with the National Electrical Code/NFPA 70/ANSI, and with all local codes and authorities having jurisdiction. Product is intended for indoor use only. 1. Remove backplane from enclosure. Do not discard hardware. 2. Trove1C1 (Fig. 5, pg. 5) Mark and predrill holes on the wall to line up with the top two keyholes in the enclosure. Install two upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the two upper screws, level and secure. Mark the position of the lower two holes. Remove the enclosure. Drill the lower holes and install the two fasteners. Place the enclosure s upper keyholes over the two upper screws. Install the two lower screws and make sure to tighten all screws. Trove2CV2 (Fig. 9, pg. 8) Mark and predrill holes on the wall to line up with the top three keyholes in the enclosure. Install three upper fasteners and screws in the wall with the screw heads protruding. Place the enclosure s upper keyholes over the three upper screws, level and secure. Mark the position of the lower three holes. Remove the enclosure. Drill the lower holes and install the three fasteners. Place the enclosure s upper keyholes over the three upper screws. Install the three lower screws and make sure to tighten all screws. 3. Mount UL Listed tamper switch (Included) (Ademco model 112 or equivalent) in desired location, opposite hinge. Slide the tamper switch bracket onto the edge of the enclosure approximately 2 from the right side (Fig. 1, pg. 1). Connect tamper switch wiring to the Access Control Panel input or the appropriate UL Listed reporting device. To activate alarm signal open the door of the enclosure. 4. Mount /CDVI modules to TC1 or TCV2 backplane, refer to pages 3 and 6. Mounting Hardware: Plastic Standoff Metal Standoff 3/8 Pan Head Screw Honeywell model # 112 Tamper Switch or equivalent (provided) Enclosure to Access Control Panel or U.L. Listed Reporting Device Fig. 1 Edge of Enclosure Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI
3 TC1: Configuration of Power Supply and/or Sub-Assembly Boards and CDVI Modules 1. Fasten standoffs (provided) to pems that match the hole pattern for Power Supply/Chargers or Sub-Assembly boards (Fig. 3, pg. 3). Fasten metal standoffs in the correct locations to provide proper grounding, see below (Fig. 3, pg. 3). 2. Mount boards to standoffs utilizing 5/16 pan head screws (provided) (Fig. 3, pg. 3). 3. Mount appropriate CDVI A22 modules into the correct positions (Fig. 3, pg. 3). by postioning standoffs over appropriate holes on the backplane and depress down on board to secure standoff to the backplane (Fig. 2, pg. 3). Note: CDVI A22 modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 3 below. 4. Fasten TC1 backplane to Trove1 enclosure utilizing pan head screws (provided). Fig. 3 - Trove1C1/TC1 Configurations Plastic Stand Off pre-mounted into CDVI Atrium modules Insert into TC1/TCV2 backplane Fig. 2 Metal Standoff Placement Power Supply Sub- Assembly Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 3 -
4 Fig. 4 TC1 Dimensions 0.5 (12.7mm) 12.5 (321.31mm) 8.15 (207.01mm) (422.9mm) (397.5mm) 6.25 (158.75mm) 0.5 (12.7mm) Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI
5 Fig. 5 Trove1C1 Enclosure Dimensions (H x W x D): 18 x 14.5 x (457mm x 368mm x 118mm) 7.25 (184.15mm) 14.5 (321.31mm) 1.45 (36.83mm) (49.483mm) 4.5 (114.3mm) 13.0 (330.2mm) 1.5 (38.09mm) (14.98mm) 1.5 (38.09mm) (14.52mm) 8.5 (215.9mm) 8.5 (215.9mm) 18.0 (457.2mm) 6.5 (165.1mm) 6.5 (165.1mm) (15.27mm) (27.83mm) 4.5 (114.3mm) 4.5 (114.3mm) 2.75 (69.85mm) (28.32mm) (34.59mm) Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 5 -
6 TCV2: Configuration of Power Supply and/or Sub-Assembly Boards and CDVI Modules 1. Fasten standoffs (provided) to pems that match the hole pattern for Power Supply/Chargers or Sub-Assembly boards (Fig. 7, pg. 6). Fasten metal standoffs in the correct locations to provide proper grounding, see below (Fig. 7, pg. 6). Note: sub-assembly position can accommodate either one (1) ACM8/ ACM8CB or two (2) PD4UL/PD4ULCB, PD8UL/PD8ULCB or MOM5. 2. Mount boards to standoffs utilizing 5/16 pan head screws (provided) (Fig. 7, pg. 6). 3. Mount appropriate CDVI A22 modules into the correct positions (Fig. 7, pg. 6). by postioning standoffs over appropriate holes on the backplane and depress down on board to secure standoff to the backplane (Fig. 6, pg. 6). Note: CDVI A22 modules have one (1) RJ45 jack each. Please make sure that they are mounted correctly, as shown in Fig. 7 below. 4. Fasten TCV2 backplane to Trove2 enclosure utilizing pan head screws (provided). Fig. 7 Plastic Stand Off pre-mounted into CDVI Atrium modules Insert into TC1/TCV2 backplane Fig. 6 Power Supply Metal Standoff Placement Power Supply or Sub-Assembly Metal Standoff Placement Sub-Assembly Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI
7 Fig (190.5mm) TCV2 Dimensions 19.4 (492.76mm) 7.5 (190.5mm) (633.73mm) ( 3.96mm) 25.4 (645.16mm) (320.55mm) (320.55mm) (215.77mm) (412.62mm) 1.0 (25.4mm) 0.45 (11.43mm) 7.5 (190.5mm) 1.0 (25.4mm) 7.5 (190.5mm) 9.2 Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI - 7 -
8 Fig. 9 Trove2CV2 Enclosure Dimensions (H x W x D): x x 6.5 (692.15mm x mm x 165.1mm) 5.25 (133.35mm) 3.50 (88.9mm) (546.1mm) 3.50 (88.9mm) 5.25 (133.35mm) (14.29mm) (61.34mm) 1.77 (44.96mm) (17.399mm) Knockouts (28.32mm) (22.479mm) 6.25 (158.75mm) 6.25 (158.75mm) 0.85 (21.59mm) 1.5 (38.1mm) (502.92mm) 6.75 (171.45mm) G (685.8mm) 8.25 (209.54mm) 8.00 (203.2mm) 0.85 (21.59mm) 1.00 (25.4mm) 5.25 (133.35mm) 7.00 (177.79mm) 5.25 (133.35mm) is not responsible for any typographical errors. Product specifications are subject to change without notice th Street, Brooklyn New York USA, , fax: website: info@altronix.com. Made in USA. IITrove1C1/Trove2CV2 - Rev F22P MEMBER Trove1C1/TC1/Trove2CV2/TCV2 - /CDVI
Installation Guide. Versatile Access Power and Integration Enclosures. Trove2M2 - Trove2 enclosure with Altronix/Mercury backplane
Versatile Access Power and Integration Enclosures Installation Guide Models Include: Trove2M2 - Trove2 enclosure with / backplane TM2 - / backplane only Trove2V2 - Trove2 enclosure with / backplane TV2
More informationAccess & Power Integration Solutions
ccess & Power Integration Solutions Installation Guide for models: T2MK3F4 - (1) eflow6n - Power Supply/Charger - (1) CM4 - Fused ccess Power Controller T2MK3F4Q - (1) eflow6n - Power Supply/Charger -
More informationExpandable Power Systems
Expandable Power Systems Installation Guide Models Include: Maximal11EV 12VDC @ 4A or 24VDC @ 3A. 12VDC @ 4A or 24VDC @ 3A. Maximal33EV 12VDC or 24VDC @ 6A. 12VDC or 24VDC @ 6A. Maximal37EV 24VDC @ 10A.
More informationDC Outdoor Power Supply/Chargers
DC Outdoor Power Supply/Chargers Installation Guide Models Include: WayPoint3 WayPoint7-2.5A @ 12VDC or 24VDC. - 6A @ 12VDC or 24VDC. - 115/230VAC input. - 115VAC input. WayPoint5 WayPoint7V - 4A @ 12VDC
More information718.567.8181 info@altronix.com 1 Trove access and power integration solutions easily combine Altronix power and accessories with access controllers available from the industry s leading manufacturers.
More information3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide
Embedded 3-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide Models include: NetWaySP3WP - Includes Fiber Optic SFP 1G, 3-port PoE+ switch and power supply. - NEMA4/4X, IP66 rated Outdoor
More information8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual
Embedded 8-Port Ethernet over Fiber PoE Hardened Switches Installation Manual NetWaySP8WP - Includes Fiber Optic SFP 1G Link, 8-port PoE switch and power supply. - NEMA4/4X, IP66 rated Outdoor enclosure.
More information4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide
Embedded 4-Port Ethernet over Fiber PoE+ Hardened Switches Installation Guide Models include: NetWaySP4WP - Includes Fiber Optic SFP 1G Link, 4-port PoE+ switch and power supply. - NEMA4/4X, IP66 rated
More informationAL168 Series Multi-Output Power Supplies
AL168 Series Multi- Power Supplies Installation Guide Models Include: AL168CB - 16VAC @ 6A (100VA) or 18VAC @ 5.5A (100VA). AL168175CB - 16VAC @ 10A (175VA). AL168300CB - 16VAC @ 18A (350VA) or 18VAC @
More informationActive UTP Transceiver Hub with Integral Isolated Camera Power
Active UTP Transceiver Hub with Integral Isolated Installation Guide HubWayEX16SP - UL Listed sixteen (16) Channel Active UTP Transceiver Hub with Integral Isolated Rev. 011810 More than just power. TM
More informationEnclosures AE1/AE3. Installation Guide
Enclosures AE1/AE3 en Installation Guide Enclosures Safety en 3 1 Safety Notice! Do not flush mount! Regulatory agency requirements prohibit flush mounting the enclosures.! Caution! Ensure the enclosure
More informationNetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC
Installation Guide NetWay1DWP - Outdoor Single Port Hi-PoE Injector NetWay1DWPM - Outdoor Managed Single Hi-PoE Injector I.T.E. 43KC Rev. 112713 Overview: Altroni NetWay1DWP Outdoor Single Port Midspan
More informationlong range ethernet Extend Ethernet range 5x the distance - without repeaters. Long Range Ethernet Adapters Features:
FEATURED PRODUCTS SECURITY / ACCESS / FIRE / SURVEILLANCE long range ethernet 2 Extend Ethernet range 5x the distance - without repeaters. - Deploy IP cameras/edge devices up to 500m over CAT5e/6. - Passes
More informationRack Mount Power Supplies
Rack Mount Power Supplies Installation Guide Models Include: VertiLine33D - 12VDC @ 8A - Sixteen (16) PTC protected outputs VertiLine33TD - 12VDC @ 16A - Sixteen (16) PTC protected outputs VertiLine63D
More informationPassive UTP Transceiver Hub with Integral Camera Power Installation Guide
Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8D HubWay16D - Eight (8) Channels - Sixteen (16) Channels HubWay82D HubWay162D - HubWay8 w/eight (8) HubWayAv - HubWay16
More informationTransceiver Hub with Integral Camera Power
Passive UTP Transceiver Hub with Integral Installation Guide Models Include: HubWay8CD HubWay16CD - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver Hub
More informationActive UTP Transceiver Hub with Integral Camera Power Installation Guide
Active UTP Transceiver Hub with Integral Installation Guide Models Include: HubWayLD8CDS - UL Listed eight (8) Channel Active UTP Transceiver Hub with Integral HubWayLD82CDS - UL Listed eight (8) Channel
More informationPassive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide
Passive UTP Transceiver Hub with Integral Isolated Installation Guide Models Include: HubWay8Di HubWay16Di - UL Listed eight (8) Channel Passive UTP - UL Listed sixteen (16) Channel Passive UTP Transceiver
More informationActive UTP Transceiver Hub with Integral Camera Power Installation Guide
Active UTP Transceiver Hub with Integral Installation Guide Models Include: HubWayLD8D HubWayLD16D - Eight (8) Channels - Sixteen (16) Channels HubWayLD82D HubWayLD162D - HubWayLD8D w/eight (8) HubWayAv
More informationPassive UTP Transceiver Hub Installation Guide
Video Data Passive UTP Transceiver Hub Installation Guide Models Include: - Sixteen (16) Camera Channels Rev. 121710 More than just power. TM Overview: Altronix Passive UTP Transceiver Hub transmits UTP
More informationInstallation and User Guide
Installation and User Guide VADDIO DOMEVIEW HD INDOOR PENDANT MOUNT DOME ENCLOSURE FOR THE VADDIO HD-20, HD-19 AND HD-18 PTZ CAMERAS Part Number: 998-9100-200 2011 Vaddio - All Rights Reserved DomeVIEW
More informationebridge200b - Managed Two Port Transceiver Board
PLUS ebridge200b - Managed Two Pt Transceiver Board Installation Guide Rev. 049207 Overview: ebridge200b long range Ethernet transceiver/media converter transmits data and power over Coax CAT5 cable over
More informationActive UTP Transceiver Hub with Integral Isolated Camera Power Installation Guide
Active UTP Transceiver Hub with Integral Isolated Installation Guide Models Include: HubWayLD8Di HubWayLD16Di - UL Listed eight (8) Channel Active UTP - UL Listed sixteen (16) Channel Active UTP Transceiver
More informationUser s Guide. Includes Mounting, Installation, and Product Registration nd Avenue NE Arlington, WA USA (+1)
User s Guide Includes Mounting, Installation, and Product Registration 500 19009 62nd Avenue NE Arlington, WA USA (+1) 360-435-6030 European Sales Office Barcelona, España (+34) 600-843-845 www.outbackpower.com
More informationInstructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only)
Instructions to Install Retrofit Kit RVMC 4/5000 Machine (MDB Only) **TURN POWER OFF OF MACHINE BEFORE INSTALLATION** READ ALL INSTRUCTIONS BEFORE STARTING INSTALLATION Retrofit Kit Contents PART NAME
More informationUniversal Desktop and Monitor Stand
Universal Desktop and Monitor Stand Installation Instructions Kit P/N: 114-6013 Kit Contents Kit Contents: (1) Stand Assembly (1) VESA Monitor Bracket (1) Bottom Bracket (1) Top Bracket (1) Clamp Bracket
More informationUSBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version
USBCNC-SW USB Disk Key reader for CNC Controls Machine Mount instructions for Universal Switcher Version 2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla Street Chatsworth, CA 91311
More informationINSTALLATION INSTRUCTIONS
INSTALLATION INSTRUCTIONS 19 20 21 01 07 22 23 13 10 12 08 17 18 11 02 14 15 04 03 16 WELCOME PARTS LIST Thank you for purchasing this HealthPoint Technology Cabinet from Humanscale! Before you begin installing
More informationInstallation Guide. Rev
Installation Guide Rev. 120913 NetWay4ES - 4-Port Managed /+ Switch NetWay4ESK - Kit includes: NetWay4ES and NetWay1E (84W Midspan Injector, 115VAC input) NetWay4ESKV - Kit includes: NetWay4ES and NetWay1EV
More informationVertiv VR Rack 1.0 GENERAL
1.1 SUMMARY Vertiv VR Rack Guide Specifications 1.0 GENERAL This specification defines the mechanical characteristics and requirements for the Vertiv VR Rack. A series of adaptive and scalable electronic
More informationEWS660AP. Quick Installation Guide
Package contents - Managed indoor access point - Power adapter - RJ-45 Ethernet cable - Mounting bracket - Mounting kit - T-Rail mounting kit IP Adress configuration Step 1: Once your computer is on, ensure
More informationINSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS)
Doc. 6001025 Rev B INSTRUCTIONS FOR THE INSTALLATION OF THE INFINITY "L" DISPLAY HOOD (INTO PREVIOUSLY INSTALLED INFINITY "L" SYSTEMS) Rev. B Doc. 6001025 Page 1 of 13 IMPORTANT NOTICE This document covers
More informationNew IP & Power Solutions. for 2018
New IP & Power Solutions for 2018 long range ethernet 2 Extend Ethernet range 5x the distance - without repeaters. - Deploy IP cameras/edge devices up to 500m over CAT5e/6. - Passes PoE/PoE+ generated
More information7403 K321. Display Wall Mount. Kit Instructions. Issue A
7403 K321 Display Wall Mount Kit Instructions Issue A ii Revision Record Issue Date Remarks A Nov 2008 First issue 1 Introduction This kit is used in to secure a 7403 Display Head on a vertical surface.
More informationATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES
1. Turn off and unplug the game. COPYRIGHT 2007 MERIT ENTERTAINMENT 2. Unlock and open the CPU section. Ion evo/evo Wallette/Elite Edge ECS Motherboard Removal 3. Remove the 3 screws securing the I/O board
More informationAM-516. Adaptor Ring. User s Manual. Complies with FD8162 fixed dome camera. Rev IP Surveillance
AM-516 Adaptor Ring User s Manual Complies with FD8162 fixed dome camera Rev. 1.0 IP Surveillance I Overview AM-516 Adaptor Ring Adaptor ring for FD8162 fixed dome camera. The supported installation types
More informationAssembly Instructions for #5630 Medication PalWOW
Assembly Instructions for #5630 Medication PalWOW Before assembling, please familiarize yourself with all the parts and check to make sure you have all the parts as listed below. A B A & B - The box in
More informationBL-FLOWSTN-P FlowStation Module Installation Guide
Introduction Baseline s FlowStation is available as an add-on module that is installed inside a pedestal enclosure with a BaseStation 3200 irrigation controller. The FlowStation module comes with a 5-port
More informationFirebox X Edge e-series De-Manufacturing Instructions
Firebox X Edge e-series De-Manufacturing Instructions Document Number: 480-2530-001 WatchGuard Technologies. Doc #480-2530-001 Rev. A Page 1 of 9 1.0 Purpose This instruction defines the de-manufacturing
More informationInstalling a Power over Ethernet injector
Installing a Power over Ethernet injector AlphaEclipse StreetSmart and RoadStar signs The instructions in this document explain how to install/replace a Power over Ethernet (PoE) injector in a StreetSmart
More informationNetwork Power Distribution Module
Please be sure to visit altronix.com for latest firmware and installation instructions Network Power Distribution Module Installation and Programming Manual Models include: LINQ8PD - Network Power Distribution
More informationINSTRUCTION BULLETIN
INSTRUCTION BULLETIN No. 9008755 Machine: T16 Published: 03-2011 Rev. 00 NOTE: DO NOT DISCARD the Parts List from the Instruction Bulletin. Place the Parts List in the appropriate place in the machine
More informationUSBCNC USB Disk Key reader for CNC Controls Machine Mount instructions
USBCNC USB Disk Key reader for CNC Controls Machine Mount instructions 2008-2015 Calmotion LLC, All rights reserved Calmotion LLC 21720 Marilla St. Chatsworth, CA 91311 www.calmotion.com Introduction This
More informationHomeWorks Remote Power Feed-Through Panels
power feed-through panels are available in two different sizes, each of which may be either surface-mounted or recess-mounted, in an electrical closet or other equipment room. The number of remote power
More informationIS-DM220/IR/HB IS-DM220
IS-DM220/IR/HB IS-DM220 Installation Guide Indoor/Outdoor Ver. 1.2 00P6NX223ZXSEA2 Table of Contents 1. Indoor Camera Installation... 3 1.1 Hard Ceiling... 3 1.2 In-Ceiling (T-Bar) Mounting... 13 1.3 4S
More informationmodular enclosure MUREVA, IP65 weatherproof & versatile enclosures aesthetics multi-functional evolutionary ergonomics and time saving security
aesthetics c Elegant and robust design. c Colour easy to integrate in any environment. weatherproof & versatile enclosures multi-functional c Different solutions for: industrial control, electrical distribution,
More informationPoE Managed Midspan Solution for Standard Network Infrastructure
Power over the Ethernet PoE Managed Midspan Solution for Standard Network Infrastructure Installation Guide Models Include: NetWay8M NetWay16M - Eight (8) Port PoE Midspan Injector - Sixteen (16) Port
More informationTerminal Equipment Controller Enclosure
Document No. 550-196 Terminal Equipment Controller Enclosure Product Description A Terminal Equipment Controller enclosure is a general-purpose metal cabinet with a removable cover that houses an electronic
More informationTruPortal Dual Door Interface Module Quick Reference
TruPortal Dual Door Interface Module Quick Reference en-us Packing List Introduction The TruPortal Dual Door Interface Module (TP-ADD-2D) can support two complete door configurations, with up to two readers
More informationInstallation Notes TII Model 341 Protector
Installation Notes TII Model 341 Protector (ATT-IS PEC 32918) for MERLIN Communications System In Range Out of Building (IROB) Station Installation By Trained Technician Only WARNING: Failure to follow
More informationPhase Loss Protection Upgrade. Phase Loss Protection Upgrade. In this bulletin:
Phase Loss Protection Upgrade In this bulletin: Introduction... 2 Purpose... 2 General... 2 Applicability... 2 HD3070 Phase Loss Protection Upgrade Kit Parts... 2 Preparation... 4 Install the Phase Loss
More informationTDM To MiniMech conversion ProceDure
TDM To MiniMech conversion ProceDure (Model 9100 ATM) TDN 07102-00079 Apr 1 2009 CorporATe HeAdquArTers: 522 E. Railroad Street Long Beach, MS 39560 PHONE: (228) 868-1317 FAX: (228) 868-0437 COPYRIGHT
More informationTELEPHONE FLUSH WALL PLATE
TELEPHONE FLUSH WALL PLATE Single Jack Modular flush wall jack assembly allows flush-mounted connection of plug-ended modular line cords. Ideal for initial installation or conversion from existing wall
More informationASSEMBLY AND ADJUSTMENT
EDGE-WALL MONITOR ARM EDGE-WALL Rev A 2/17 Model EDGE-WALL-SLV ASSEMBLY AND ADJUSTMENT EDGE-WALL MONITOR ARM PLEASE REVIEW these instructions before beginning the installation. Check that all parts and
More informationHow to Design Custom Enclosures for Motherboard-Based Systems
PROTOCASE TECHNICAL BULLETIN How to Design Custom Enclosures for Motherboard-Based Systems (covering ATX and Mini ITX form factors) Document Edition - 1 Last Updated: June 6 th,2011 Protocase, Inc. All
More informationTensionLitePlus Kiosk Design 4
TensionLitePlus Kiosk Design 4 TensionLite Plus Kiosks combine lightweight aluminum tube frames with state-of-the-art printed stretch zipper pillowcase fabric graphics to create funky and functional multimedia
More informationSITRANS F. Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel. Introduction 1. Installing/Mounting 2. Hardware Installation Instructions
Introduction 1 Installing/Mounting 2 SITRANS F Flowmeters SysCom Upgrade Kit IP65 (NEMA 4X) Multi-Channel Hardware Installation Instructions 1/2010 A5E02518333A Revision 04 Legal information Warning notice
More informationModels 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions
299-600-96 Rev. F MCG Surge Protection Models 120LS, 200LS, 300LS, 400LS, 560LS Installation Instructions Important Warranty Information: MCG surge protectors are designed to work at specific voltages
More informationEthernet/Network Communications Module. Installation and Programming Manual. LINQ2 - Two (2) Port Connectivity Module. More than just power.
Ethernet/Network Communications Module Installation and Programming Manual LINQ2 - Two (2) Port Connectivity Module DOC#: LINQ2 Rev. 060514 More than just power. Overview: Altronix LINQ2 network module
More information15P0097Q1 SINUS K - PENTA REMOTE MOUNTING THE KEYPAD MOUNTING GUIDE
15P0097Q1 THE KEYPAD MOUNTING Upd. 12/01/06 R. 01 English This manual is integrant and essential to the product. Carefully read the instructions contained herein as they provide important hints for use
More informationPortable Staging User Guide
Portable Staging User Guide Components: ExpressDeck was designed for quick and easy assembly: set up is a snap, even if you have no experience! So let s take a moment to meet the components of your new
More informationProbably the fastest enclosure in the world
95 9 enclosure system Probably the fastest enclosure in the world Sample configuration tools required no no tools required Vitaro can be assembled within less than 60 seconds. 00:00 00:0 00:08 00: 00:5
More informationPACSystems* RX3i IC695ACC650
September 2012 PACSystems* RX3i IC695ACC650 Series 90-70 to RX3i Conversion Rack The conversion rack provides a solution for converting an existing Series 90-70 system to PACSystems RX3i, minimizing outage
More informationTruPortal Output Expansion Board Quick Reference
TruPortal Output Expansion Board Quick Reference en-us Packing List Introduction A TruPortal system can be expanded by adding an Input/Output Expansion module (TP-ADD-IO-BRD) that consists of: One TruPortal
More informationHAW-SIBU. Rack Installation Guide. Version 1.0.1
HAW-SIBU Rack Installation Guide Version 1.0.1 Mounting HAW-SIBU in a Rack The instructions here apply to the Sony HAW-SIBU. Cautions * Do not lift or move the HAW-SIBU unit by the handles on the ear brackets
More informationINSTALLATION INSTRUCTIONS: E KIT-EMV-INGENICO ICMP CRADLE-PAYPOINT E KIT-EMV-VERIFONE E355 CRADLE-PAYPOINT
E953516 KIT-EMV-INGENICO ICMP CRADLE-PAYPOINT E002639 KIT-EMV-VERIFONE E355 CRADLE-PAYPOINT 1 1- Add payment module to bracket (1) 2 Screws, X2 3- Add payment module/bracket (1) to bracket (2) with 2 screws
More informationDOCKING STATION SPECIFICATIONS
ONE PERSON STATION Power Outlets Data Jack Plate Mouse Brackets Front Covers Cable Holes Cable Holes Overview: The Docking Station distributes power, data, and laptop storage to each user. It also offers
More informationE1135C PDU and Pod Upgrade Procedure
E4030-90010 Rev. B 12/2003 In this Document... Tools Needed, 2 Contents of the Upgrade Kits, 2 Installation Procedures, 4 Verifying the Power Option of the New PDU, 4 Removing the PDU from the Support
More informationSeries Amp Pad Mount Quick Connect Input and Output Power Panels
Series 300 2000-4000 Amp Pad Mount Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury.
More informationFormulate Accent - 04
Formulate Accent - 04 FMLT-WL04 Formulate accents enhance the funtionality of any 10ft or 20ft backwall and add more real estate for messaging too! With monitor supports, literature pockets, shelves, tables,
More informationXDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116
XDBKITS5 Bus / DB Terminal Kit (Size 5) Installation Manual DPD00116 XDBKITS5 Option Kit Installation Manual vacon 3 Installing the Bus / DB Terminal Option Kit Introduction The XDBKITS5 option kit is
More informationGV-EL124S Electric Strike
GV-EL124S Electric Strike Featured with a built-in door status sensor, the GV-EL124S is a fail-secure electric strike, but it is field convertible from fail secure to fail safe. It can be mounted either
More informationQuick Start Guide. SEB-710 I/O Expansion board. Introduction
SEB-710 I/O Expansion board Revision 1.0 - (March, 2011) Saflec Systems (Pty) Ltd Quick Start Guide Introduction The SEB-710 is an I/O expansion device for additional inputs and outputs. It has eight relay
More informationEaton LCD Lift Flat Panel Display System. Installation Guide
Eaton LCD Lift Flat Panel Display System Eaton LCD Lift Flat Panel Display System Installation Guide Copyright 2011 Eaton Corporation, Worcester, MA, USA. All rights reserved. Information in this document
More informationAssembly Instructions Triton Enclosure for Poseidon With Data Acquisition November, 2007 V0.9 DSC Document #
Assembly Instructions Triton Enclosure for Poseidon With Data Acquisition November, 2007 V0.9 DSC Document #7521002 Diamond Systems Corp. (650) 810-2500 www.diamondsystems.com This document describes how
More informationSeries Amp Quick Connect Input and Output Power Panels
Series 300 1200-1600 Amp Quick Connect Input and Output Power Panels DANGER is used in this manual to warn of a hazard situation which, if not avoided, will result in death or serious injury. WARNING is
More informationPXC Compact Unitary Equipment Controller (UEC)
Document No. 553-169 PXC Compact Unitary Equipment Controller (UEC) Product Description The PXC Unitary Equipment Controller (UEC) is an MS/TP device that can be configured as a programmable, stand-alone
More informationFLEXBOX. Installation Guide
FLEXBOX Installation Guide FLEXBOX 1 Important Safety Instructions WEIGHT LIMIT MAXIMUM WEIGHT 50 LBS. THE STRUCTURE TO WHICH THE BOX IS MOUNTED (CEIL- ING, WALL, TABLE, POLE) MUST BE ABLE TO SUPPORT FIVE
More informationIn-ceiling Housing. Installation Manual SHP-3701F
In-ceiling Housing Installation Manual SHP-3701F TABLE OF CONTENTS Overview 3 What s Included 3 Installation Instructions 4 Installation (SCP-3430 Series) 4 Installation (SCP-3370/SNP-5200 SERIES) 9 Installation
More informationTECHKNOW, INC. Kiosk Order Confirmation System INSTALLATION MANUAL. Revision Date: July 11, 2012 Part # Version 3.2
document Page 1 of 18 TECHKNOW, INC Kiosk Order Confirmation System INSTALLATION MANUAL Revision Date: July 11, 2012 Part # Version 3.2 Techknow, Inc. 393 Mayfield Road Duncan, SC 29334 www.gotechknow.com
More informationEP/2 Installation Instructions
1 2 3 4 7 ENTER 0 5 6 8 9 CLEAR + - LOGIC ONE EP/2 EP/2 Installation Instructions DOC. #569011000 A 7/30/04 PRINTED IN U.S.A. Regulatory Compliance Safety This device has been tested and found to be in
More informationATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES
Hard Drive Removal IMPORTANT NOTE: If you are replacing a PATA hard drive with a SATA hard drive, please see PATA to SATA Hard Drive Conversion. Hard Drive Identification: To determine whether your hard
More informationINSTALLATION INSTRUCTIONS
TM REPLACEMENT PARTS FOR USE WITH CX SERIES PANELS INSTALLATION INSTRUCTIONS Hubbell Control Solutions 9601 Dessau Road Building One Suite 100 Austin, TX 78754 Toll Free: 888-698-3242 Fax: 512-450-1215
More informationPowerLogic High Density Metering System 1-Meter Enclosure
PowerLogic High Density Metering System 1-Meter Enclosure Installation Guide 63230-508-211A1 Safety information PowerLogic High Density Metering System 1-Meter Enclosure Important information Read these
More informationWireless Key fob, Key pad & Receiver Range
Wireless Key fob, Key pad & Receiver Range 4Ch Wireless Receiver 4x Voltage Free relay outputs (NO + NC) 100m Transmission range Multiple user codes 2 Channel wireless control Clear hinge up lid 12V DC
More informationTSMIU Wireless Bridge Installation and Configuration
ation uration EPM Software must be 7.6.0.16 or greater and latest 750-E700B MIU code Hardware Installation 1. To install wireless bridge / bracket assembly and antenna, the MIU must be turned off and the
More informationKit K Instructions. V8700 to Alpha Conversion Instructions
V8700 to Alpha Conversion Instructions Contents Contents Installation Instructions for Kit K-00927-0001 Before You Begin..................................................................................
More informationATTENTION: OBSERVE PRECAUTIONS FOR HANDLING ESD-SENSITIVE DEVICES
Hard Drive Removal IMPORTANT NOTE: If you are replacing a PATA hard drive with a SATA hard drive, please see PATA to SATA Hard Drive Conversion. Hard Drive Identification: To determine whether your hard
More information7" Touch Screen Display
7" Touch Screen Display Installation Guide Contents Minimum Requirements...1 Select a Location...1 Initial Setup...2 Unboxing...2 Installation...3 Prepare the Panel...3 Install the Mounting Plate...3 Mount
More informationWarning Before Installation. Package Contents EN-1. Power off the Network Camera as soon as smoke or unusual odors are detected.
English Warning Before Installation Power off the Network Camera as soon as smoke or unusual odors are detected. Do not place the Network Camera on unsteady surfaces. Do not insert sharp or tiny objects
More informationTo Purchase This Item, Visit BMI Gaming (800)
OWNERS AND SERVICE MANUAL INNOVATIVE CONCEPTS IN ENTERTAINMENT INC. 10123 MAIN STREET, CLARENCE, NY 14031 SERVICE: 1-716-759-0360 FAX: 1-716-759-0884 E-MAIL: service@icegame.com WEBSITE: www.icegame.com
More informationThanks for shopping with Improvements! Chalet Standard Mailbox Item # (With 1 Line Plaque) Item # (With 2 Line Plaque)
Thanks for shopping with Improvements! Chalet Standard Mailbox Item #476200 (With 1 Line Plaque) Item #476242 (With 2 Line Plaque) To order, call 1-800-642-2112 West Chester, OH 45069 Made in China 1014
More informationPCLASS Integrated Paxton Access Power
PCLASS Integrated Paxton Access Power All-in-one multi-door power solutions for Paxton Net2 and BLU controllers. Single and Dual Voltage, Standard and Networked. PCLASS Product Guide {jatabs type="content"
More informationPart Name/Description Part Number Quantity
Part Name/Description Part Number Quantity Direct Command Kit 4100883 1 Installation Instructions 2006336 1 Hardware Kit Large Module 2001354-1 2 Cable Installation Kit 2000901-1 1 Quick Reference Card
More informationTyler - Middle Mount For Bell 407, 206 & 206L Series Helicopters FAA STC # SH3246NM
MIDDLE MOUNT 407 / JET RANGER / LONG RANGER INSTALLATION MANUAL Tyler - Middle Mount For Bell 407, 206 & 206L Series Helicopters FAA STC # SH3246NM PLEASE RETURN THIS MANUAL WITH EQUIPMENT This manual
More informationPlease read thoroughly before starting installation and check that kit contents are complete.
Chrysler/Dodge/Jeep Remote Add-On CD player for RA1, RA2, RA3, or RA4 radios (Kit # 5000-8750) 2013-current RAM truck and Viper; 2015-current Charger, Challenger, and 300; 2017 Pacifica Please read thoroughly
More informationFortiCam FD40 Mounting Guide
FortiCam FD40 Mounting Guide 1 FORTINET DOCUMENT LIBRARY http://docs.fortinet.com FORTINET VIDEO GUIDE http://video.fortinet.com FORTINET BLOG https://blog.fortinet.com CUSTOMER SERVICE & SUPPORT https://support.fortinet.com
More informationPortable Staging User Guide
Portable Staging User Guide Components: Putting together your smart stage system was designed to be simple enough for anyone to do easily. Nonetheless, let s take a moment for a little meet and greet A.)
More informationUse flat head screws for the out side of chassis and pan head screw for inside of chassis.
These are instructions are guidelines in building a Storage Pod. 2-a Use flat head screws for the out side of chassis and pan head screw for inside of chassis. 1. Take the main chassis and check the chassis
More informationUltima X5000 Rectangular Duct Mount Kit User Instructions
Ultima X5000 Rectangular Duct Mount Kit User Instructions MSA Kit 10176947 - Ultima X5000 316 Stainless Steel Parts List / Instructions Rectangular Gasket (1) Rectangular Duct Mount Base Plate (1) Base
More information