1 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite TR TR 610 top2 G D Montage- und Bedienungsanleitung 1 Schaltuhr für Kleinlasten 2 0,5mm - 2,5mm 2 8mm V~ 50-60Hz R 10a - 30T GB F Notice de montage et d utilisation 13 Horloge programmable pour faibles charges MENU 1 OK top2 TR 610 I Istruzioni per il montaggio e per l uso 25 Timer per carichi minimi 16(6) 250V~ C O Montage- en bedieningshandleiding 37 Schakelklok voor kleine lasten G Assembly and operating instructions 49 Time switch for small loads TR 610 top2 G
2 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 2 Contents Basic advice 51 Screen display and keys/operating principle 52 Menu overview 53 Connection/assembly 54 Initial start-up 55 Menu item PROGRAM Reprogram switching time 56 Change switching time 57 Menu item MANUAL Manual and permanent switching 58 Menu item OPTIONS PIN code 58 Memory card OBELISK top2, RESET 59 Technical data 60 Service address/hotline 60 50
3 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 3 Basic advice WARNING Danger of death through electric shock or fire! ÿ Installation should only be carried out by professional electrician! GB The device is designed for installation on DIN top hat rails (in accordance with EN 60715) Corresponds to type 1 STU in accordance with IEC/EN , designed for use in normal environment Power reserve (10 years) is reduced with memory card inserted (in battery mode) Designated use: The time switch is used to control tasks in small load applications For use only in closed, dry rooms Suitable for switching SELV (Safety Extra-Low Voltage) devices Disposal Dispose of equipment in an environmentally-friendly manner 51
4 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 4 Screen display and keys Operating principle Programmed switch times Date display Channel status ON OFF Display of active buttons with relevant function Time display Days of the week from Read text line Flashing text/symbol represents question 2. Make decision ÿ MENU Activate display Open menu Terminate programme ESC (Leave menu) ÿ ÉÑ Alternatives are displayed ÿ OK Save selection Confirm selection YES Confirmation OK press NO Change/ revise ÉÑ press 52
5 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 5 Menu overview MENU OFF 9:40 46 PROGRAM TIME/DATE MANUAL OPTIONS END NEW TIME PERM ON OPERATING HOUR GB CHECK SET DATE PERM OFF LCD ILLUMINA- TION MODIFY DELETE SU-WI WEEK DAY OVERRIDE ON HOLIDAY LANGUAGE PIN END FORM DATE END FACTORY SETTINGS FORM TIME INFO END END 53
6 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 6 Connection/installation Connect cable WARNING Warning, danger of death through electric shock! ÿ Must be installed by professional electrician! ÿ Disconnect power source. ÿ Cover or shield any adjacent live components. ÿ Ensure device cannot be switched on! ÿ Check power supply is disconnected! ÿ Earth and bypass! ÿ Strip cable by 8 mm (max. 9). ÿ Insert cable at 45 in the open terminal (2 cables per terminal is possible). ÿ Only for flexible wiring: Press screwdriver downwards to open spring screwless terminal. Spring screwless terminal Spring screwless terminal NC contact Test tap 45 cable 54
7 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 7 Initial start-up (see fig.) GERMAN YEAR Set date, time and summer-/winter time rule MONTH DAY HOUR GB ÿ Press desired button and follow on-screen instructions. MINUTE SU-WI EUROPA ok SU-WI GB/IRL/P SU-WI FIN/GR/ TR ok OFF 9:40 46 SU-WI CDN SU-WI USA07 SU-W IRAN SU-WI FREE RULE SU-WI FIX DATE NO SU-WI 55
8 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 8 Reprogram swtiching time (see fig.) PROGRAM ok NEW ÿ Press MENU. ÿ Confirm with OK or select desired setting ÉÑ. ÿ Reconfirm with OK. You have 56 memory locations available. SWITCH FREE 56 ON On HOUR MINUTE same switching time for several days = Block SAVE ADD TUESDAY COPY MONDAY SAVE Switching time for one day 56
9 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 9 Change/delete switching time (see fig.) ÿ Press MENU. ÿ Confirm with OK or select desired setting ÉÑ. ÿ Reconfirm with OK. PROGRAM NEW CHECK MODIFY DELETE ok SWITCH MONDAY GB You can either change or delete a block, i.e. a switching time copied for several days (e.g. Mon-Fri) or a single switching time. MODIFY HOUR MODIFY MINUTE MODIFY BLOCK MODIFY SINGLE DAY 57
10 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 10 Manual and permanent switching Manual and permanent switching can be selected by using menu option MANUAL or (in the automatic display) via a combination of buttons (see fig.). PIN code The PIN code is set in the menu under OPTIONS (see fig.). If you have lost the PIN call the Theben Hotline. OPTIONS OPERATING HOUR Activate manual switching LCD ILLUMINA- TION ÿ Quickly press both buttons simultaneously. Activate permanent switching ÿ Press both buttons simultaneously for 2 seconds. LANGUAGE PIN FACTORY SETTINGS ok WITH PIN CURRENT PIN Cancelling manual/permanent switching ÿ Press both buttons simultaneously. INFO NEW PIN
11 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 11 Memory card OBELISK top2 Use memory card ÿ Insert memory card in the time switch. ÿ Request saved switch timings, read to/from the time switch or start Obelisk program. ÿ Memory card OBELISK top2 (No ) after Programming etc. remove and store in cover. Avoid mechanical overload or contamin ation caused by other storage/transport. RESET COPY OBELISK -> CLOCK COPY TCLOCKI -> OBELISK RUN OBELISK CHECK OBELISK ÿ Press the 4 buttons simultaneously. You can choose between KEEP PROGRAM and DELETE PROGRAM. GB 59
12 TERMINA 610 top2_gb_sel 170 top_neu_ _D :12 Seite 12 Technical data Nominal voltage: V~, +10 %/-15 % Frequency: Hz Power consumption: typ. 8 VA Switching output: switching of choice of phase is permitted Contact: suitable for for switching smallest loads and SELV Type of contact: contact μ Contact material: AgNi 90/10-htv Switching capacity max.: 16 A, 250 V~, cos ϕ = 1; 2 A, 250 V~, cos ϕ = 0.6 Switching capacity min.: < 1 ma/< 1 V Shortest switching time: 1 minute Accuracy: ±0,25 s/day at +25 C Power reserve: 10 years at 20 C Permissible ambient temperature: 30 C C Protection class: II in accordance with EN for designated installation Protection rating: IP 20 in accordance with EN Pollution degree: 2 Rated impulse withstand voltage: 4 kv Service address/hotline Service address Theben AG Hohenbergstr Haigerloch GERMANY Phone Fax: Hotline Phone Fax: hotline@theben.de Addresses, telephone numbers etc.
TR TR 608 top TR 609 top D GB F I E NL. Installation and operating instructions Digital time switch. TR 609 top2
309559 01 TR TR 608 top2 6080100 TR 609 top2 6090100 L N 230-240V~ 3 µ 50-60Hz R10a -25T 2 1 16(4)A 250V~ GB Installation and operating instructions Digital time switch D GB F I E NL TR 609 top2 MENU OK
More informationLUNA LUNA 120 top2 D GB F I E P NL PL. Installation and operating instructions Twilight switch. LUNA 120 top2
2 309 272 01 LUNA LUNA 120 top2 GB 120 0 100 120 0 200 0 6 12 18 24 Installation and operating instructions Twilight switch MENU 1 OK 2 Lux 2000 LUNA 120 top2 D GB F I E P NL PL 2600 W 16A-10AX 250V~ 0,5mm
More informationLUNA LUNA 111 top2 LUNA 112 top2 D GB F I E P , , Assembly and operating instructions Digital twilight switch
2 2 309 271 01 LUNA LUNA 111 top2 LUNA 112 top2 111 0 100, 111 0 200 112 0 100, 112 0 200 Ext L N Data + 4 5 6 C2 Ext1 Ext2 L N Data + GB Assembly and operating instructions Digital twilight switch MENU
More information1. Basic safety information 4 2. Proper use 4
307075 EN Time switch TR 611 top2 6110100 TR 622 top2 6220100 1. Basic safety information 4 2. Proper se 4 Disposal 4 3. Installation and connection 5 Monting the time switch 5 Connecting the cable 7 Disconnecting
More information1. Basic safety information 3 2. Proper use 3
0 6 12 18 24 0 6 12 18 24 307262 01 4 5 6 C2 0,5mm 2-2,5mm 2 8mm 230-240V~ 50-60Hz R 10a -30T 0,5mm 2-2,5mm 2 8mm 230-240V~ 50-60Hz R 10a -30T EN Time switch DV1K 108272 DV2K 108273 MENU OK 1 C1 16(10)A
More informationOperating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2
Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2 Dear client, if you have the newer device, please use page 1 to 33 RAMSES RAMSES 811 top2 RAMSES 831 top2 8119132 8319132
More informationclick DuoFix screwless Plug-in screwless terminal NC contact Test tap
307098 Time switch installation EN Astro Time Switch SELEKTA 170 top2 1700100 1. Basic safety information WARNING Danger of death from electric shock or fire! ¾Installation shold only be carried ot by
More informationRAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2
309 358 04 RAMSES RAMSES 811 top2 RAMSES 831 top2 811 9 132 831 9 132 RAMSES 812 top2 RAMSES 832 top2 812 0 132 832 0 132 GB Installation and operating instructions Room thermostat D GB F E I NL RAMSES
More informationVARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX
307031 VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX 8269210 8269211 GB Installation and operating instructions Room thermostat D GB F I E NL VARIA 826 S KNX Contents Basic safety instructions 3 Display
More information1. Basic safety information 4 2. Proper use 4
8mm 0 6 12 18 24 µ 307263 01 L N EN Astro Time Switch ASTRO1K 108274 0,5mm 2-2,5mm 2 MENU 16(10)A 250V~ 230-240V~ 50-60Hz R 10a -30T OK 1 2 3 1. Basic safety information 4 2. Proper se 4 Disposal 4 3.
More information1. Basic safety information 4 2. Proper use 4
+ 2 µ 2 1 Ext 1 307266 01 L N EN Astro Time Switch ASTRO1K1M 108277 230-240V~ 50-60Hz R10a -25T 16(4)A 250V~ MENU OK 1. Basic safety information 4 2. Proper se 4 Disposal 4 3. Installation and connection
More informationData sheet no Data sheet General data sheet Status: 00 hst/ml Distribution: Valid from: Release: Device no.:
Data sheet TR 671 top2 TR 672 top2 Page 1 of 8 Device characteristics Device type Memory slots Operation User guidance Display lighting Program display Summer/Winter time Copy Time format Date format 1
More informationPlug-in screwless terminal NC contact. OBELISK top2 memory card ( )
307038 45 cable E Digital twilight switch UA 111 top2 1110100/ 1110200 UA 112 top2 1120100/ 1120200 oad line connection Plg-in screwless terminal C contact Test tap 1. Basic safety information! WARIG Danger
More informationD GB F NL I E P. Overview per day of the programmed switching. Channel statuses are displayed ON / OFF
D GB F NL I E P 310 783 03 TR 610 top TERMINA 1-channel 7 day timers According to version preprogrammed with the current time and summer/ winter norm time Safety Information The connection and installation
More informationProduct and Applications Description. Application Programs. Example of Operation. Installation Instructions. load circuit AC 230/400V L1 L2 L3 N
Product and Applications Description Application Programs 20 A4 Binary 906401 4 binary outputs 1 status request available for each output 1 relation can be set allows 1 positive drive for each output initial
More informationProduct and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005
Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program
More informationSwitching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX
Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1
More informationProduct and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More informationETD-BL-1T-OFF-CC- 10S
Timer relay with off delay (with control contact) and adjustable time Data sheet 103617_en_03 1 Description PHOENIX CONTACT - 2013-09-16 Features Compact timer relay in 6.2 mm housing for controlling time
More informationVEO. V2UF230V10 Art.Nr.: TECHNICAL DATA
Continous voltage monitoring Mains fluctuation detection Detects voltage drop / short interruptions of at least 10ms Prevents undefined states in switching and control systems Generates reset pulse after
More informationPSR-SCP- 24DC/SSM/2X1 PSR-SPP- 24DC/SSM/2X1
PSR-SCP- DC/SSM/2X1 PSR-SPP- DC/SSM/2X1 Safety Relay With Downtime Monitoring INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- DC/SSM/2X1 safety relay can be used in safety circuits
More informationProduct and functional description
Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,
More informationMonitoring technique. VARIMETER Voltage relay MK 9064N, MH 9064
Monitoring technique VARIMETER Voltage relay MK 9064N, MH 9064 0269462 Your Advantages Preventive maintenance For better productivity Quicker fault locating Precise and reliable Min-, Max. value or window
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationProduct and functional description
Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus
More informationSiemens Spares. RL 513D23 Switching actuator (relay), 3 x 6A. Technical Product Information
Gamma instabus Technical Product Information RL 513D23 Switching actuator (relay), 3 x 6A 5WG1 513-4DB23 Switching actuator for independent switching of three lighting luminaire groups or other loads one
More informationPSR-PC50. SIL 3 coupling relay for safety-related switch on. Data sheet. 1 Description
SIL 3 coupling relay for safety-related switch on Data sheet 105818_en_01 PHOENIX CONTACT 2014-08-18 1 Description The PSR-PC50 SIL coupling relay can be used for power adaptation and electrical isolation
More informationControl elements. Fine adjustment. Status indication. 24 V DC typ. 0,25 W / 0,25 VA. 24 V DC typ. 0,03 W / 0,09 VA. 0,15 3 s. 0,5 10 h.
On-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationProduct and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs
Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).
More informationVEO. V2ZR V AC/DC Art.Nr.: V2ZR10P V AC/DC Art.Nr.: TECHNICAL DATA
Off-Delay 10 time ranges Supply voltage 24-240V AC/DC 1 change-over contact Width 22,5 mm Control elements Fine adjustment Setting of time range Status indication LED U/t: Supply voltage LED R: Relay status
More informationVEO. V2ZS V AC/DC Art.Nr.: V2ZS20P V AC/DC Art.Nr.: TECHNICAL DATA
4 time ranges 4 transition times Supply voltage 12-240V AC/DC 2 normally open contacts Width 22,5 mm Control elements Fine adjustment star contactor Setting of time range star contactor Transit time Status
More informationProduct and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012
Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982201 The push button interface UP 220/31 is a binary input and output devices for installation
More informationProduct and functional description
Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,
More informationProduct and functional description
Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.
More informationOPERATING MANUAL. Quality control system on the production complies with requirements ISO 9001:2008
Ltd Intelligent industrial electronics Astronomical time relay REV 225 OPERATING MANUAL Quality control system on the production complies with requirements ISO 9001:2008 Dear customer, Company LTD. thanks
More informationISOMETER isoev425 with coupling device AGH420
with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles Preliminary datasheet isoev425_d00126_02_d_xxde/09.2015 with coupling device
More informationPSR-SCP- 24DC/URM4/4X1/2X2/B PSR-SPP- 24DC/URM4/4X1/2X2/B
Safety Relay as a Contact Extension Block INTERFACE Data Sheet PHOENIX CONTACT - 05/2006 Description The PSR-...- 24DC/URM4/4X1/2X2/B safety relay can be used as a contact extension block in safety circuits
More informationREDUNDANCY MODULE TSP-REM360 AND TSP-REM600
REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side
More informationEMD-FL-C-10. Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks
Electronic monitoring relay for overcurrent and undercurrent monitoring of direct and alternating current in single-phase networks INTERFACE Data Sheet 102057_en_01 Description PHOENIX CONTACT - 02/2008
More informationPHOENIX CONTACT - 07/2006
Buffer module with maintenance-free capacitor-based power storage device INTERFACE Data sheet 102035_03_en PHOENIX CONTACT - 07/2006 Description Short-term mains interruptions are bridged by QUINT BUFFER,
More informationTechnical data sheets
echnical data sheets Ready-to-connect spring return actuator with emergency function for VAV and CAV units in ventilation and air conditioning systems in buildings For air dampers up to approx. 4 m 2 orque
More informationPHOENIX CONTACT - 01/2007
Uninterruptible power supply INTERFACE Data Sheet 103123_00_en PHOENIX CONTACT - 01/2007 Description Especially compact and easy-to-use, the new MINI-DC-UPS/ 24 DC/2 is a combination of the power supply
More informationPush Button Interface UP 220D31
Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982203 The push button interface is a binary input and output devices for installation in in-wall
More informationElectronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-ERS.12 ON-delayed with 1 c/o (SPDT) contact The CT-ERS.12 is an electronic timer from the CT-S range with ON-delay and 10 time ranges. All electronic timers from the CT-S
More informationESB A ESB A
ESB00163 16A ESB00323 32A Made in Germany Inrush Current Limiter, Inrush Protector, 3-phase 200/400/500Vac For capacitive loads, models with 16A & 32A, -40 C... +55 respective +70 C Short Specification:
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More informationDALI Professional Controller-4. Control unit Operating instructions
LI Professional Controller-4 Control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Description... 5 Purpose and application 5 Configuration 5 Design 5 Connections
More informationZCM-12, ZCM-12P/U TIME PROGRAMMER WEEK S, DOUBLE CHANNEL
ZCM-12, ZCM-12P/U TIME PROGRAMMER WEEK S, DOUBLE CHANNEL INSTRUCTION MANUAL ZAMEL Sp. z o.o. ul. Zielona 27, 43-200 Pszczyna, Poland Tel. +48 (32) 210 46 65, Fax +48 (32) 210 80 04 www.zamelcet.com, e-mail:
More information584 5WG AB_1 DELTA
Product DELTA profil DELTA style DELTA ambiente Display and control unit 5WG1 585-2AB01 pearl grey 5WG1 585-2AB11 titanium white 5WG1 585-2AB21 anthracite 5WG1 585-2AB71 silver 5WG1 585-2AB11 titanium
More informationFP735Si Electronic 3-Channel Full Programmer for Heating and Hot Water with Service Interval Timer. Installation Guide MAKING MODERN LIVING POSSIBLE
MAKING MODERN LIVING POSSIBLE FP735Si Electronic 3-Channel Full Programmer for Heating and Hot Water with Service Interval Timer Danfoss Heating Installation Guide For a large print version of these instructions
More informationVoltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages
Data sheet Voltage monitoring relays CM-ESS.1 For single-phase AC/DC voltages The CM-ESS.1 is an electronic voltage monitoring relay that provides reliable monitoring of voltages as well as detection of
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 2 safety contacts (N/O), delay-on de-energisation
More informationRhino Buffer Module PSM24-BFM600S. Operating Instructions
Rhino Buffer Module PSM24-BFM600S Operating Instructions RHINO BUFFER MODULE PSM24-BFM600S Description The PSM24-BFM600S Buffer Module will hold the output voltage of a 24 VDC power supply after brownouts
More informationProduct and functional description
Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The
More informationPHARAO. Compact controllers for installation and automation technology
PHARAO Compact controllers for installation and automation technology Various expansion modules PHARAO-II 25 (DC) 2 Communication in all directions By connecting a GSM modem, it is now possible to send
More informationElectronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-EBD.12 Flasher starting with ON with 1 c/o (SPDT) contact The CT-EBD.12 is an electronic time relay with the function flasher starting with ON. It is from the CT-D range.
More informationOperating instructions AS-i SmartLine module AC3200 AC /00 06/2016
Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target
More informationDemonstration Case BENNING DB 1
Operating manual Demonstration Case BENNING DB 1 part no. 044132 Table of contents 1 Introduction...3 2 Safety instructions...4 3 Applicable regulations...5 4 Device description...5 4.1 Measuring / testing...
More informationProduct and function description
GAMMA instabus The following display and operating functions can be configured: switching, switching with forced control, dimming, sun protection control, recall and save scenes, sending and displaying
More informationMINI MCR-SL-UI-2I. Configurable signal duplicator. Data sheet. 1 Description
Configurable signal duplicator Data sheet 102382_en_03 PHOENIX CONTACT 2012-05-02 1 Description The MINI MCR-SL-UI-2I(-SP)(-NC) configurable signal duplicator is used to electrically isolate, condition,
More informationElectronic timer CT-SDS.23 Star-delta change-over with 2 n/o contacts
Data sheet Electronic timer CT-SDS. Star-delta change-over with n/o contacts The CT-SDS. is an electronic timer from the CT-S range with Star-delta change-over and 7 time ranges. All electronic timers
More information02/11/2015
35 mm - 1 Relay 8A OUR1 Part number 88867105 Multi-function or mono-function Multi-range Multi-voltage Relay output 1 or 2 : 8 A - 250 V (10 A UL) LED status indicator Option of connecting an external
More informationElectronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-APS.21 OFF-delayed with 2 c/o (SPDT) contacts The CT-APS.21 is an electronic timer from the CT-S range with OFF-delay. It provides 10 time ranges and a continuous rated control
More informationProduct and Applications Description. Note. Example of Operation. Installation Instructions. Application Programs WARNING
Product and Applications Description Note If the application program is not loaded completely by the ETS, you had better interrupt the 24 V voltage supply of the I/O-module during the loading interval.
More informationZEITSCHALTUHR TIMER SWITCH TIJDSCHAKELKLOK KOPPLINGSUR RELOJ TEMPORIZADOR IDŐZÍTŐ KAPCSOLÓ ΧΡΟΝΟΔΙΑΚΟΠΤΗΣ DZ 20-A V2
DZ 20-A V2 ZEITSCHALTUHR Bedienungs- und Sicherheitshinweise TIJDSCHAKELKLOK Bedienings- en veiligheidsinstructies TIMER SWITCH Operation and Safety Notes KOPPLINGSUR Bruksanvisning och säkerhetsanvisningar
More informationAC5160 Controller. Fire & Security Products. SiPass integrated
AC5160 Controller SiPass integrated Wall housing with pre-assembled SiPass basic components Equipped with one ACC, two DRI and one power supply Extendable with additional components The AC5160 is a wall
More informationCPCI-PS24 24V-Power Supply
24V-Power Supply Hardware Manual to Product I.2301.21 esd electronic system design gmbh Vahrenwalder Str. 207 30165 Hannover Germany http://www.esd.eu Phone: +49 (0) 511 3 72 98-0 Fax: +49 (0) 511 3 72
More informationMINI MCR-SL-PT100-UI-200
Configurable temperature transducer for PT00 INTERFACE Data sheet 078_en_0 PHOENIX CONTACT 00-0-5 Description The MINI MCR-SL-PT00-UI-00... is a configurable -way isolated temperature transducer. It is
More informationTP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Installation and User Instructions
TP5000 Si Range Electronic 5/2 day programmable room thermostat Mains, Battery and RF versions Certification Mark GB Installation and User Instructions GB Index Index 3-14 Product Specification 3 Installation
More informationSafe timer relay/contact expansion modules
Contact expander module for increasing the number of available contacts, Pulse-on timer relay for step-by-step control of movement sequences, Delay-on energisation timer for unlocking an interlock with
More informationVIBRATION MONITOR CX-RLY
VIBRATION MONITOR CX-RLY MaintTech Norrkoping Airport Sweden Email: mainttech@live.se Website: www.mainttech.se 1 CX-RLY-C MODULE Version 1 1 Important User Information Solid-state equipment has operational
More informationIndustrial motor controller for brushed DC motors 24 VDC
Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 6 A Control with the following functions: - reversal of direction of rotation - overcurrent shutdown depends on
More informationBulletin 817 Thermistor Protection Relay
6 Bulletin 817 Accurate Temperature Monitoring for Critical Applications Automatic, Manual and Remote Reset Status Indicating LEDs DIN Rail or Panel Mounting Guarded Terminals IP20 1 N.O. and 1 N.C. Output
More informationElectronic timer CT-SDD.22 Star-delta change-over with 2 n/o contacts
Data sheet Electronic timer CT-SDD. Star-delta change-over with n/o contacts The CT-SDD. is an electronic time relay with star-delta change-over. It is from the CT-D range. With their MDRC profile and
More informationElectronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact
Data sheet Electronic timer CT-ARS.11 OFF-delayed without auxiliary voltage with 1 c/o (SPDT) contact The CT-ARS.11 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges
More informationElectrical data Nominal voltage AC/DC 24 V Nominal voltage frequency
echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet
More informationSafety Switching Devices SNO 4003K. Basic device for Emergency-Stop and Safety Gate Applications PI E
EN 60204-1 Stop category 0 EN 954-1 Safety category 4 Basic device to EN 60204-1 and EN 954-1 single E-stop monitoring. Manual or automatic start Application up to safety category 2 and stop category 0
More informationOperating instructions. Speed monitor D / / 2014
Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5
More informationPHOENIX CONTACT - 01/2010. Features. DANGER OF EXPLOSION! Only remove equipment when it is disconnected and not in the potentially explosive area.
Uninterruptible power supply with integrated power supply unit INTERFACE Data sheet 104211_en_00 1 Description PHOENIX CONTACT - 01/2010 Features The MINI-DC-UPS provide an uninterruptible DC voltage both
More informationDigital time switch SHT-1/2 - two channel - with daily and weekly program. Operating manual. Content. 1. Before you start Features of the device
Digital time switch SHT-1/2 - two channel - with daily and weekly program Operating manual 2115;211-2-1 Rev.: Thank you for buying this device. As a reward for your confidence you will get hight technical
More informationQUINT-DC-UPS/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/10 Order No.: 2866226 Uninterruptible power supply 24 V DC/10 A, with integrated 1.3 Ah battery module. In the download area, there is a clearly arranged
More informationElectronic timer CT-ERD.12
2CDC 251 092 F0t06 a Rotary switch for the preselection of the time range b Potentiometer with direct reading scale for the fine adjustment of the time delay c U: green LED V control supply voltage applied
More informationPower supply. Interface technology in modular housing DIN rail devices, IM series. Features
Features 2,2 kò,5 W 5 V 5,1 V,3 W 24 VDC 2,5 A GN / L 85...264 VAC 9...375 VDC / N Safety extra-low voltage SELV IEC/ EN 695 Output voltage adjustable 24 28 VDC Nominal current 2.5 A Single/parallel operating
More informationQUINT-DC-UPS/24DC/40. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-DC-UPS/24DC/40 Order No.: 2866242 Uninterruptible power supply 24 V/40 A. In the download area, there is a clearly arranged selection table available with load currents
More informationRM84 miniature relays
RM84 miniature relays RM84 Contact data Number and type of contacts Contact material Rated / max. switching voltage Min. switching voltage Rated load (capacity) AC AC1 AC15 DC1 DC13 Motor load acc. to
More information24 V DC typ. 0,65 W. Liquid level with conductive probes (type SK1, SK5) Resistance measurement E1-E0, E2-E0, E3-E0, E4-E0
monitoring in conductive liquids 4 probe inputs for level monitoring Multifunction Adjustable sensor voltage Supply voltage 24-240V AC/DC Protective separation of measuring circuit 3 normally open contacts
More information1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions
DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please
More informationOperating and mounting instructions
General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore
More informationRTU500 series Data Sheet Power Supply CP-E 24/2.5
Data Sheet Power Supply CP-E 24/2.5 Power Supply CP-E 24/2.5 Application The primary switch mode power supply offers two voltage input ranges. This enables the supply with AC or DC. Furthermore it is equipped
More informationPositive-guided relay outputs: 4 safety contacts (N/O), instantaneous
ohne Abbildung Contact expansion module for increasing the number of available contacts Approvals PZE X4.1P with universal power supply Unit features Positive-guided relay outputs: 4 safety contacts (N/O),
More informationILBIB24DO16-DSUB. Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors
Inline Block IO Module for INTERBUS With 16 Digital Outputs; Bus Connection via D-SUB Connectors AUTOMATIONWORX Data Sheet 7119_en_02 PHOENIX CONTACT - 03/2007 Description The ILB IB 24 DO16-DSUB module
More informationis then retained absolutely without interruption.
Page 1 of 11 DC UPS uninterruptible power supplies - DC UPS module 6 A Compact design, only 50 mm wide Simple DIN rail mounting Absolutely interruption-free buffering of mains failures through immediately
More information2. Safety information 3
1. Contents 2 1. Contents Page 2. Safety instructions 3 3. Assembly, putting into operation, connection 4 4. Control elements 5 5. Display 6 6. General 7 7. Factory setting 8 7.1 Changing the settings
More informationISOMETER isopv with coupling device AGH-PV
Insulation monitoring device for unearthed AC, AC/DC and DC systems (IT systems) for photovoltaic plants up to AC 793 V/DC 1100 V Vorläufiges Datenblatt IsoPV_D00024_02_D_XXEN/07.2018 ISOMETER with coupling
More informationPSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B
PSR-SCP- 24DC/SDC4/2X1/B PSR-SPP- 24DC/SDC4/2X1/B Safety Relay for Emergency Stop and Safety Door Circuits INTERFACE Data Sheet 102858_02_en PHOENIX CONTACT - 12/2006 Description The PSR-...- 24DC/SDC4/2X1/B
More informationDANGER indicates that death or severe personal injury will result if proper precautions are not taken.
SIMATIC ET 200S distributed I/O SIMATIC ET 200S distributed I/O Digital electronic module 4DI DC24V HF (6ES7131-4BD01-0AB0) Manual Preface Properties 1 Parameters 2 Diagnostics 3 04/2007 A5E01077141-01
More informationElectronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts
Data sheet Electronic timer CT-ARS.21 OFF-delayed without auxiliary voltage with 2 c/o (SPDT) contacts The CT-ARS.21 is an electronic timer from the CT-S range with true OFF-delay. It provides 7 time ranges
More informationPSR UC/ESAM4/3X1/1X2/B
Safety relay for emergency stop and safety door monitoring Data sheet 105318_en_02 PHOENIX CONTACT 2014-06-13 1 Description The safety relay can be used in safety circuits according to EN 60240-1 and IEC
More informationISOMETER isoev425/isoev425hc with coupling device AGH420
with coupling device AGH420 Insulation monitoring device for unearthed DC circuits (IT systems) for charging electric vehicles isoev425_d00126_04_d_xxen/06.2018 with coupling device AGH420 Insulation monitoring
More informationMINI MCR-SL-PT100-UI. Active resistance thermometer measuring transducer. Data sheet. 1 Description
Active resistance thermometer measuring transducer Data sheet 099_en_06 PHOENIX CONTACT 0-0- Description The 6. mm wide MINI MCR-SL-PT00-UI-... is a configurable, -way isolated temperature measuring transducer.
More information