1 VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX GB Installation and operating instructions Room thermostat D GB F I E NL VARIA 826 S KNX
2 Contents Basic safety instructions 3 Display and push buttons 4 Overview 5 Connection 6 Installation/Dismantling 7 Programming physical address, bus connection 8 User operation Start-up 9 Hotkey function/operating modes 10 Room temp. controller 11 Weather menu 14 Professional electrician operation Weather forecast menu (6 h) 16 Page freely programmable via ETS 17 SETTINGS menu 20 PIN, date and time, setpoint values, time program, language, display, system Technical date 29 Service address/hotline 29 Table : Set program 2
3 Basic safety instructions GB WARNING Danger of death through electric shock or fire! Installation should only be carried out by a professional electrician! The device can be installed in flush-mounted sockets in walls and is designed for use in a normal environment; device complies with EN Professional installation of bus lines and commissioning of devices requires compliance with the provisions of EN for switches or similar installation equipment for use in building systems technology! Tampering with, or making modifications to, the device will invalidate the guarantee Designated use VARIA controls all room functions such as heating, air conditioning, ventilation, lighting and sun protection Only to be used in closed, dry rooms (house, office, conservatory etc.) Disposal Dispose of device in environmentally sound manner 3
4 Screen and keys Select settings Row END Store and confirm selection change values Date display Temperature display Time program display for temperature control Time display Operation mode symbol Comfort, standby modes, temperature reduction at night, frost protection, comfort extension etc. Fan 4
5 Overview For daily use... For occasional use... GB Room temp. controller Set point value 22.0 C Operation mode Comfort Fan stepl auto Overview. Room temp. controller Set point value Operation mode Fan level Overview.. SETTINGS Date and time.... Temperature.. Switching program.. Language.. Display.. System.. End settings Weather Temperature 21.7 C Wind 7.3 km/h Brightness 200 Lux Rain no Min/max values.. Weather forecast (6h) Temperature setpoint value Precipitation Rain amount Wind force Continue.. Weather Temperature Wind Brightness Rain Min/Max values.. Weather forecast (6h) Temperature Precipitation Rain amount Wind force Continue.. Settings Date and time Temperature Switching program Language Display System Close settings 5
6 Connection WARNING Danger of death through electric shock! Must only be installed by professional electrician! Disconnect power source! Cover or shield any adjacent live components. Ensure device cannot be switched on again! Check power supply is disconnected! Earth and bypass! Ensure installation height of 1.5 m. 6
7 Installation All 3 lugs on the device (top and bottom) must be firmly clicked into place. Remove protective film. GB Dismantling Press down on the top of the device with a screwdriver to release the device from the wall. Montage Demontage 7
8 Program physical address Move a magnet along the right upper side of the device. The programming LED lights up VARIA is in program mode The program mode can also be set using the settings menu under system. Bus connection Open cover. Plug bus line into bus terminals. Ensure correct polarity. Plug bus terminal into the device. Close flap. MAGNET Bus line Bus terminal Start-up, diagnostics and configuration are handled by ETS (KNX tool software). Remove bus line Remove the bus line with a twist-pull motion from the bus terminal. 8
9 User operation Start-up Date and time are preset ex works. Different pages can be displayed. The pages displayed depends on the programming by a professional electrician. Please refer to the Product Handbo for detailed functional descriptions (at GB Fr 09/05/13 11: C Auto Quick access Room temperature control Example for a Favorites/Overview page With the keys set desired room temperature. 9
10 Fr 09/05/13 11: C Auto Hot key function Special function for easy switch on/off (e.g. lighting). Function: The light can be switched on or off by pressing the buttons / or. This function must be activated by a professional electrician. Fr 09/05/13 11: C Auto Operation modes/fan levels You can choose between 5 operation modes: Comfort mode Standby mode Temperature reduction at night Frost protection Comfort extension Fan: You can choose Auto, On/Off or the fan levels 1, 2, 3. 10
11 Room thermostat temp. controller Weather Weather forecast (6h) SETTINGS Room temp. controller menu Room temperature/change setpoint value Press button. Confirm room temperature controller with. With set the desired set point. Confirm with. GB Room temp. controller Set point value C 22.0 C Operation mode Comfort Fan step auto Overview.. 11
12 Change operation mode Room temp. controller Set point value 21.7 C Operating mode Comfort Fan step auto Overview.. Press button. Confirm room temperature controller with. With the keys select operating mode. With set the desired operating (page 10) mode. Confirm with. Comfort extension is not possible if presence detectors are used. 12
13 Room temp. controller Set point value 21.7 C Operation mode Comfort Fan step Auto Overview.. Change fan stage Press button. Confirm room temperature controller with. With the keys select fan level. With set the desired fan level. The following appears in the display when a fan coil actuator is connected. You can choose from Auto, On/Off or fan levels 1, 2, 3. GB Overview.. Fr 09/05/13 11: C Auto Press button. Confirm room temperature controller with. With the keys select overview. Confirm with. The overview page appears. 13
14 Weather menu Room temp. controller Weather Weather forecast (6h) SETTINGS Display for temperature, wind speed, brightness and rain values (from a weather station) Query weather data Press button. With the keys Confirm with. select weather. Weather Temperature 21.7 C Wind 7.3 km/h Brightness 200 Lux Rain no Min/max values The weather data appears in the display. 14
15 Weather Temperature 21.7 C Wind 7.3 km/h Brightness 200 Lux Rain no Min/max values.. Query min/max values Press button. With the keys select weather. Confirm with. Confirm min/max values with. GB The minimum and maximum temperature, wind and rain values are displayed from the start of the recording operations. Rest min/max values Min/max values Since 23/06/08 3 pm Min Max Temp C Wind km/h Rain --- Reset Back With Reset. Confirm with. The record is deleted and restarted. The min/max values function only appears if it is selected by the professional electrician. 15
16 Professional electrician operation Weather forecast menu (6h) Room temp. controller Weather Weather forecast (6h) SETTINGS (the menu only appears when it was set by the electrician) Press button. With the keys select Weather forecast (6h). Confirm with. The weather data appears in the display. Weather forecast (6h) Temperature setpoint value Precipitation Rain amount Wind force Continue.. 16
17 Pages freely programmable via ETS Display of values and control of different functions in 8 lines: light scenes, sun protection systems, etc. (up to 40 values/functions). GB LIVING ROOM Ceiling light ON Standard lamp OFF Temperature 21.7 C Operation mode Comfort Heating performance 0% Window open Shutter position 100 % The texts are set by the professional electrician and appear automatically in the display. Press button. With the keys Confirm with. select e.g. living room. 17
18 LIVING ROOM PAGE 1 Switching ON Temperature 21.7 C Operation mode Comfort Heating performance 0% Window open Shutter position 100 % Dimmer off 1. "Switching" example With select Switching. Press push button. The displayed value changes, a telegram is sent. Press. The displayed value is sent. LIVING ROOM PAGE 2 Active switching on Temperature 21.7 C Operation mode Comfort Heating performance 0% Window open Shutter position 100 % Dimmers Dimming ON 2. "Dimming" example With select. Dimming Press push button briefly. The light is switched On/Off. Press push button and hold for some time. This appears : The dimming telegram is sent. Press. The displayed value is sent. 18
19 BEDROOM PAGE 3 Active switching on Temperature 21.7 C Operation mode Comfort Blinds Window ON open Shutter position 100 % Dimmer off 3. "Blinds" example With select Blinds. Press push button briefly. The blinds slat position is changed. Press push button and hold for some time. This appears : The corresponding value is sent. GB A professional electrician can adjust the setting so that the blinds stop once the button is released or when is pressed. BEDROOM PAGE 3 Light scene Temperature ON 21.7 C Operation mode Comfort Blinds Window open Shutter position 100 % Dimmer off 4. Example: "Temperature", "Light scenes", "Percentage values" etc. With e.g. select Light scene. Press push button briefly. Press. The displayed value is sent. 19
20 Professional electrician operation SETTINGS menu Room temp. controller Weather Weather forecast (6h) SETTINGS The PIN code appears first (if set by professional electrician). Press button. Using the push buttons select SETTINGS. Enter the figures with and confirm with. SETTINGS Date and time.... Temperature.. Switching program.. Language.. Display.. System.. Close settings Afterwards using Confirm with. select desired line. 20
21 Date and time :56:47 Summer-Winter: EU Back Setting date and time.. With select desired line. Confirm with. With change the value. Confirm with. GB Set temperature Set room temperature: Comparison with the existing Temperature Room temp 20.5 C Cool/Heat 21.0 C Cool/Heat 19.0 C Cool/Heat 16.0 C Back room temperature With select desired line. With change the value. Confirm with. Each value can be set separately. There are, however, minimum/maximum permitted differences between the values, which are automatically adjusted if necessary. 21
22 Set time program There are 8 channels with weekly programs (minimum switching interval of 15 min.) (see table on page 30). Channel 1 is allocated to the room thermostat (RTR) and has the following operation modes: Temperature reduction at night, standby and comfort For every channel can no program can be selected among: the fixed programs (Prog 13) a freely programmable program (own program) Time program Channel Intern: Prog 1: Prog 1 1 Channel 2: Own prog Channel 3: Own prog Channel 4: Own prog Channel 5: No prog Channel 6: No prog Channel 7: No prog Back With select desired channel. Using select program. Confirm with. If no prog. or prog. 13 is selected, a previously programmed internal program is faded out rather than deleted. 22
23 Channel 1: Prog Weekday: Monday Details... Copy to: Channel 2 Back Set time program You can now can select between various functions: Weekday, Details.., Copy to.. Using the Details.. menu, you can see all the programs in detail. GB The buttons on the VARIA device are given a different function. Example: tt Back Channel 1 Monday 00:0000: p End time program q Move left in time bar Move right in time bar Arrow in display points to current time in time bar 0-24 hrs Select operation mode Back Arrow shows the relevant operation mode P 23
24 Set time program Channel 2: Own prog Weekday: Monday Details..... Copy to: Channel 3 Copy to: Tuesday Back Set own program The buttons now have a different function (see p. 23). Details Using the Details.. menu, you can change the operation mode or switching status or time. Back P With select the operating mode or with or set the desired time. Channel 2 Monday 06:0006:15 t u Confirm with. 24
25 Back On Off Channel 2 Monday 07:0012: P Set specific times e.g. set time from 7:0012:00 (ON) With set the arrow to 7:00 am. With select On. With set the arrow to 12:00 am. Confirm with. GB Back On Off Channel 2 Monday 07:0012:00 t u P 25
26 Copy to: Tuesday (example) Channel 2: Own prog Day of the week: Monday Details... Copy to: Channel 3 Copy to: Tue Back With the push buttons Copy to: Tuesday select With set the day of the week. Confirm with. Copy to: Channel 3 (example) Channel 2: Own prog Day of the week: Monday Details... Copy to: Channel 3 Back With the push buttons Copy to: Channel 3 With set the channel. Confirm with. select The whole weekly program is copied. 26
27 Language English English French Italian Spanish Dutch Swedish Back Setting the language With Confirm with. select desired line. GB Setting the display Display Key sound: On Key light: Off Max. brightness: 100% Back With With select desired line. change the value. Confirm with. 27
28 System System Prog. mode: active Phys. addr SW: 043 S/N: FD: 0036 Back Professional electrician operation only! Prog. mode: with change. Phys. add. (physical address) SW (Software version) S/N (Serial number) FD (Finishing date) 28
29 Technical data Operating voltage: Bus voltage KNX V DC Power input KNX bus: 10 ma (without key light) 24 ma (with 100 % key light) Bus terminal: bus connection Power reserve: 1.5 years Permissible ambient temperature: 0 C C Protection class: III in accordance with EN Protection rating: IP 20 Mode of operation: type 1 SU in accordance with EN Battery type: CR2032 Rated impulse voltage: 0,8 kv Pollution degree: 2 The ETS database is available at Please refer to the KNX Handbo for detailed functional descriptions. Service address/hotline Service address Theben AG Hohenbergstr Haigerloch GERMANY Tel Fax Hotline Tel Fax hotline@theben.de Addresses, telephone numbers etc. GB 29
30 Table 1: Set program Feste (unveränderliche Programme) bei VVARIA 824 und 826 Programm Zeit 00:00-01:00 01:00 02:00 02:00 03:00 03:00 04:00 04:00 05:00 05:00-06:00 06:00-07:00 07:00-08:00 08:00-09:00 09:00-10:00 10:00-11:00 11:00-12:00 12:00-13:00 13:00-14:00 14:00-15:00 15:00-16:00 16:00-17:00 17:00-18:00 18:00-19:00 19:00-20:00 20:00-20:00 21:00-22:00 22:00-23:00 23:00 24:00 Prog 1 Mo-Fr Komfort Standby Nacht Prog 1 Sa, So Komfort Standby Nacht Prog 2 Mo-Fr Komfort Standby Nacht Prog 2 Sa, So Komfort Standby Nacht Prog 3 Mo-Fr Komfort Standby Nacht Prog 3 Sa, So Komfort Standby Nacht
TR TR 608 top TR 609 top D GB F I E NL. Installation and operating instructions Digital time switch. TR 609 top2
309559 01 TR TR 608 top2 6080100 TR 609 top2 6090100 L N 230-240V~ 3 µ 50-60Hz R10a -25T 2 1 16(4)A 250V~ GB Installation and operating instructions Digital time switch D GB F I E NL TR 609 top2 MENU OK
More informationOperating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2
Operating instructions for RAMSES 811 top2_812 top2 and RAMSES 831 top2_832 top2 Dear client, if you have the newer device, please use page 1 to 33 RAMSES RAMSES 811 top2 RAMSES 831 top2 8119132 8319132
More informationRAMSES D GB F NL. Installation and operating instructions Room thermostat. RAMSES 832 top2
309 358 04 RAMSES RAMSES 811 top2 RAMSES 831 top2 811 9 132 831 9 132 RAMSES 812 top2 RAMSES 832 top2 812 0 132 832 0 132 GB Installation and operating instructions Room thermostat D GB F E I NL RAMSES
More informationLUNA LUNA 120 top2 D GB F I E P NL PL. Installation and operating instructions Twilight switch. LUNA 120 top2
2 309 272 01 LUNA LUNA 120 top2 GB 120 0 100 120 0 200 0 6 12 18 24 Installation and operating instructions Twilight switch MENU 1 OK 2 Lux 2000 LUNA 120 top2 D GB F I E P NL PL 2600 W 16A-10AX 250V~ 0,5mm
More informationTR TR 610 top2 G
TERMINA 610 top2_gb_sel 170 top_neu_310 719_D 31.03.14 17:12 Seite 1 309346 03 TR TR 610 top2 G 610 0 110 D Montage- und Bedienungsanleitung 1 Schaltuhr für Kleinlasten 2 0,5mm - 2,5mm 2 8mm 230-240V~
More informationLUNA LUNA 111 top2 LUNA 112 top2 D GB F I E P , , Assembly and operating instructions Digital twilight switch
2 2 309 271 01 LUNA LUNA 111 top2 LUNA 112 top2 111 0 100, 111 0 200 112 0 100, 112 0 200 Ext L N Data + 4 5 6 C2 Ext1 Ext2 L N Data + GB Assembly and operating instructions Digital twilight switch MENU
More informationUse of the application program. Table of Contents. GAMMA instabus Application program description. April B0 CO Room Control Unit
Use of the application program Product family: Product type: Manufacturer: Displays Display and operating units Siemens AG Name Room control unit UP 227 DELTA i-system Order no.: Table of Contents 5WG1
More informationTebis application software
5 Tebis application software SXB322AU V 1.x 2 inputs / 2-output module LED SXB344AU V 1.x 4 inputs / 4-output module LED Product reference Product designation TXB322AU TXB344AU Embedded module: 2 inputs
More informationProduct and function description
GAMMA instabus The following display and operating functions can be configured: switching, switching with forced control, dimming, sun protection control, recall and save scenes, sending and displaying
More informationWeather station AP 257/51
Gamma instabus Weather station GPS AP 257/61 Weather station AP 257/51 Technical product information 5WG1 257-3AB61 5WG1 257-3AB51 Weather station with sensors to survey temperature, brightness, rain and
More informationProduct and Applications Description. Application programs. instabus EIB Technical Product Information. February 2012
Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982201 The push button interface UP 220/31 is a binary input and output devices for installation
More informationWeather station GPS AP 257/61 Weather station AP 257/51
Gamma instabus Weather station GPS AP 257/61 Weather station AP 257/51 Technical product information 5WG1 257-3AB61 5WG1 257-3AB51 Weather station with sensors to survey temperature, brightness, rain and
More informationKNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX
2CKA001473B8667 23.02.2017 KNX Technical Manual Busch-Presence detector KNX / Busch-Watchdog Sky KNX Busch-Presence detector mini KNX 6131/20-xxx Busch-Presence detector mini, premium, KNX 6131/21-xxx
More informationPush Button Interface UP 220D31
Product and Applications Description Application programs UP 220/31 07 B0 S4 On-off-toggle/Dim/Shu/Value 982203 The push button interface is a binary input and output devices for installation in in-wall
More informationApplication description for the KNXnet/IP Interface Web
Contents 1. General 1. General... 1 1.1 Basic information about the KNX/EIB BUS... 1 1.2 Application versions......1 1.3 Symbols...1 1.4 Function description... 2 1.5 Short description of the function
More informationSupplementary operating instructions for your air curtain system Controller TMC 500
Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016
More informationApplication description
Manufacturer Berker Motion detector Application description KNX motion detector module comfort 1.10m KNX motion detector module comfort 2.20m ETS KNX motion detector module comfort 1.10m ETS KNX motion
More information1. Basic safety information 4 2. Proper use 4
307075 EN Time switch TR 611 top2 6110100 TR 622 top2 6220100 1. Basic safety information 4 2. Proper se 4 Disposal 4 3. Installation and connection 5 Monting the time switch 5 Connecting the cable 7 Disconnecting
More informationProduct and functional description. Application Program. instabus EIB Technical product information. April (6 x AC 230 V / 0,05 A)
Product and functional description also functions if the bus cable is not connected or if the bus communication fails. After a long push button action (> 2 s), the other valve group is selected. The yellow
More informationInstallation Instructions
Dual EIB bus coupler Order no.: 1246 651, 1246 661, 1246 671 rmation The Gira SmartSensor is a product of the Instabus KNX/EIB System and complies with KNX/EIBA directives. The functions of the device
More informationKNX/EIB Push button sensor 3 Plus F Safety instructions. 2 Device components. 3 Function
Push button sensor 3 Plus 2-gang F100 Order No. : 2042 xx Push button sensor 3 Plus 3-gang (1+2) F100 Order No. : 2043 xx Push button sensor 3 Plus 6-gang (2+4) F100 Order No. : 2046 xx Operating instructions
More information1373-1-8645 23.09.2014 Operating Instructions Comfort timer control element for blind, light, and relay control 6455-101-500 6455-101-509 1 Safety... 4 2 Intended use... 4 3 Environment... 4 4 Setup and
More informationUC102 basic version with display and knob UC102BL version with display, knob and backlight UC102DK version without knob and display
UC102 Communicative heating controller Summary UC102 is a communicative room heating controller with two inputs and one PWM output for control of a radiator or electrical heater. It can work autonomously,
More information/ 2CKA001473B KNX Technical Reference Manual ABB i-bus KNX. Room temperature controller with display 6108/18-500
1473-1-8913 / 2CKA001473B8913 23.03.2016 KNX Technical Reference Manual ABB i-bus KNX Room temperature controller with display 6108/18-500 Table of contents Table of contents 1 s on the instruction manual...
More informationRoom controller LS 990 / LS plus Stainless Steel / Aluminium
Room controller LS 990 / LS plus Stainless Steel / Aluminium 1 RCDES 2021 RCDES 2022 RCDES 2023 RCDES 2024 RCDES 2044 2 Ref.-No. KNX room controller display ETS-product family: Heating, ventilation, A/C
More informationTemperature control unit
Temperature control unit 5739 18/19 Installation manual Part. U3582A - 12/08-01 PC Contents 1 - Introduction 5 1.1 - Warnings and tips 5 1.2 - Contents of package 5 2 - Description of the Control unit
More informationPush-buttons 18. Light scenes push-buttons 21. Push-buttons with thermostat 22. Labelling ields 24
A wide array of alternative materials and colours have been added to the convenient variety of KNX functionality of the. Frameless KNX push-button with full-material rockers (glass, stainless steel and
More informationUser instructions. By-me automation module for video door entry unit.
User instructions By-me automation module for video door entry unit. Contents CONTENTS 1. The By-me module 1 2. Description 2 3. Main menu 2 3.1 Settings 3 3.1.1 Home automation system settings 3 Time
More informationProduct documentation
Product documentation Universal push-button module with integrated BCU, 1-gang Universal push-button module with integrated BCU, 2-gang Universal push-button module with integrated BCU, 3-gang Universal
More informationDELTA profil wall switch, single UP 241/2 5WG AB_2
UP 241/2 5WG1 241-2AB_2 UP 241/3,with status LED 5WG1 241-2AB_3 UP 243/2 5WG1 243-2AB_2 UP 243/3,with status LED 5WG1 243-2AB_3 UP 245/2 5WG1 245-2AB_2 UP 245/3,with status LED 5WG1 245-2AB_3 UP 245/4,with
More informationProduct and Application Description
Technical Product - Information Product and Application Description The room temperature controller UP 237K and UP 252K are available in the following colors, matching the design of the wall switch design
More informationProduct and functional description
Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The
More informationApplication description. KNX Push-button module 1gang. KNX Push-button module 2gang
Application description KNX Push-button module 1/2gang Electrical/mechanical data: see the operating instructions for the product Order number Product designation Application programme TP product Radio
More informationProduct and Function Description
Product and Function Description and the LED display. The touchscreen can be used to select from up to 6 languages for the display of texts and messages. The room temperature controller integrated in Contouch
More informationEASY application description KNX room thermostat/room controller. Application description
Application description Electrical/mechanical data: see the operating instructions for the product Order number Product designation Application programme TP product Radio product 8044 01 00 KNX thermostat
More informationeelecta & new products
eelecta & new products Home and Building Evolution Eelectron - Via Magenta 77/22, I-20017 Rho (MI), Italy Eric Ducros eric.ducros@eelectron.com +39 02.9316681 www.eelectron.com info@eelectron.com www.eelectron.com
More informationDELTA i-system wall switch single UP 221/2 5WG AB_2
DELTA i-system wall switch single UP 221/2 5WG1 221-2AB_2 UP 221/3,with status LED 5WG1 221-2AB_3 wall switch double UP 222/2, 5WG1 222-2AB_2 UP 222/3,with status LED 5WG1 222-2AB_3 wall switch triple
More informationEY-RU 355: Room operating unit, ecounit355
Product data sheet 1.1 94.041 EY-RU 355: Room operating unit, ecounit355 How energy efficiency is improved Individual setting of occupancy and absence as well as room setpoint correction, control of lights
More information252F 5WG FB_1 DELTA
Product DELTA i-system DELTA profil Fan-Coil Unit Operator Panels Hotel titanium white 5WG1 237-2FB11 pearl grey 5WG1 252-2FB01 carbon metallic 5WG1 237-2FB21 titanium white 5WG1 252-2FB11 aluminum metallic
More informationProduct and functional description
Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus
More informationGAMMA instabus Application Program Description. November CO Touch-Panel
Use of the application program Product family: Product type: Manufacturer: Name: Order no.: Name: Order no.: Display Display units Siemens UP 588/2 Colour Touch Panel (AC 230 V) 5WG 588-2AB2 UP 588/22
More informationApplication description. Motion detector KNX- BCU
Application description Motion detector KNX-BCU Electrical/mechanical data: see the operating instructions for the product Order number Product designation Application programme TP product Radio product
More informationProduct and functional description
Product and functional description Connection example The universal dimmer main module N 528/31 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,
More information/ 2CKA001473B Technical Reference Manual Busch-SmartTouch. Busch-SmartTouch 7'' 6136/07-xxx-500
1473-1-9264 / 2CKA001473B9264 25.08.2017 Technical Reference Manual Busch-SmartTouch Busch-SmartTouch 7'' 6136/07-xxx-500 Tabl e of cont ents Table of contents 1 s on the instruction manual... 11 2 Safety...
More informationLUXORliving System manual Version 1
LUXORliving System manual Version 1 2018-04-18 Contents 1 General 3 2 System 4 3 Installation 5 4 Start-up 7 4.1 Establish a connection 7 4.2 Configuration with LUXORplug 10 4.3 Programming with LUXORplug
More informationSwitching Actuators N530, 6AX Switching Actuators N532, 10AX Switching Actuators N534, 16/20AX
Gamma instabus Technical Product nformation Switching Actuators N53, 6AX Switching Actuators N532, 1AX Switching Actuators N534, 16/2AX 4x AC 23V 5WG1 53-1DB31 5WG1 532-1DB31 5WG1 534-1DB31 8x AC 23V 5WG1
More informationKNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :
Blind actuator 4-gang 24 V DC Order-No. : 2154 00 Blind actuator 4-gang 230 V AC Order-No. : 2160 00 Blind actuator 2-gang 230 V AC Order-No. : 2152 00 Blind actuator 4-gang 230 V AC Order-No. : 1039 00
More informationEY-RU : Room operating unit, ecounit
Product data sheet 94.040 EY-RU 341...346: Room operating unit, ecounit341...346 How energy efficiency is improved Individual setting of occupancy and absence as well as a room setpoint correction and
More informationApplication description. KNX push-button 1gang. KNX push-button 2gang. KNX push-button 3gang. KNX push-button 4gang. Page 1/51
Application description KNX push-button 1, 2, 3 and 4gang Electrical/mechanical data: see the operating instructions for the product Order number Product designation Application programme TP product Radio
More informationProduct and functional description
Product and functional description Connection example The universal dimmer submodule N 528/41 is an installation device for DIN-rail mounting, with N-system dimensions. It is designed for lighting control,
More informationPush button UP 287, 4 - fold
Product DELTA profil DELTA style Push button 1-fold pearl grey 5WG1 241-2AB01 titanium white 5WG1 285-2AB11 titanium white 5WG1 241-2AB11 basalt black 5WG1 285-2AB21 anthracite 5WG1 241-2AB21 titanium
More informationapplication software
application software application software RF input product Electrical / Mechanical characteristics: see product user manual Product reference Product designation TP device RF devices 8565 52 xx 8565 62
More informationEY-RU : Room operating unit, ecounit
Product data sheet 9.00 EY-RU 31...36: Room operating unit, ecounit31...36 How energy efficiency is improved Individual setting of occupancy and absence as well as a room setpoint correction and control
More informationInstruction Manual Digital socket box timer
Instruction Manual Digital socket box timer Grässlin UK Vale Rise Tonbridge/Kent TN9 TB Tel. (0 ) 98 88 Fax (0 ) www.tfc-group.co.uk OK page Safety precautions, short description, wiring diagram... Installation...
More informationEIB/KNX ENO Radio bus interface (32-channel)
EIB/KNX ENO Radio bus interface (32-channel) Interface between EnOcean and EIB/KNX, on-wall mounting (Quelle: EIBMARKT GmbH, Reference No.: N000406) Page 1 Application EIB/KNX ENO Radio bus interface acts
More informationBuilding Control GAMMA instabus
The worldwide standard for home and building control Building Control GAMMA instabus siemens.com/gamma The comprehensive GAMMA instabus product portfolio comprises intelligent devices and is your key to
More informationKNX S-B2-UP. Actuator for 230 V or 24 V. Installation and Adjustment
EN KNX S-B2-UP Actuator for 230 V or 24 V Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical data... 3 1.2. Structure... 4 1.2.1. Structure 230 V AC version... 4 1.2.2. Structure
More informationGlass sensors 35. Supplementary products 39
Understatement is an art, and the makes it perfect. Up to eight functions are concealed under a pure surface that is practically flush with the wall, and can be custom-labelled on request. A single touch
More informationProduct and functional description
Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.
More informationProduct documentation
Product documentation Rotary sensor ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 58579 Schalksmühle Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-2 04 kundencenter@jung.de www.jung.de Service Center Kupferstr.
More informationColour Touch Panel 3.5
Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R Colour Touch Panel 3.5 User manual-ver. 1.2 CHTF-35/01.1 CHTF-35/01.2.21 CHTF-35/01.2.22 CHTF-35/01.2.24 KNX/EIB Intelligent Installation Systems
More informationIntegration Note OVERVIEW AND SUPPORTED FEATURES
Manufacturer: Model Number(s): KNX Climate (Various) Minimum Core Module g! 5.4 Version: g! 6.2 Minimum for Fan Coil Climate Modes Document Revision Date: 10/8/2015 OVERVIEW AND SUPPORTED FEATURES Integration
More informationRoom controller STRA-17
Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control
More informationKNX DALI Gateway Plus - User Manual
KNX DALI Gateway Plus - User Manual Item No.: LC-013-064 1. Product Description The KNX DALI gateway Plus is the interface between the KNX installation and the DALI lighting system. It allows up to 64
More informationKNX S4-B10 230V. Multifunctional Actuator. Installation and Adjustment
EN KNX S4-B10 230V Multifunctional Actuator Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical data... 4 2. Installation and start-up... 5 2.1. Notes on installation... 5 2.2. Device
More information76 F. Ductless Split Air Conditioner. YR-E16b Wired Controller User Manual WARNING
Ductless Split Air Conditioner YR-E16b Wired Controller User Manual Set temp. 76 F Indoor temp. 70 F Indoor humidity 32%RH Qty. online Standby Defrost Master Outdoor temp. 36 F Outdoor humidity 32%RH Mode
More information1 Safety instructions. 2 Device components. KNX Touch/Glass sensor comfort
Touch/Glass sensor 1gang comfort with bus coupling unit Order No. : 7514 1x xx Touch/Glass sensor 2gang comfort with bus coupling unit Order No. : 7514 2x xx Touch/Glass sensor 3gang comfort with bus coupling
More informationUse of the application program
Use of the application program Product family: Product type: Manufacturer: Display Display units Siemens AG Name: Contouch Room Controller UP 204 Order no.: 5WG1 204-2AB11, titanium white, 5WG1 204-2AB21,
More informationInstallation and User Guide
D5 Installation and User Guide 8-Channel DALI Controller (478) Introduction The 478 is for controlling DALI ballasts, drivers and load interface units (except for the 490 Blinds Controller). Do not connect
More informationINSTRUCTIONS FOR USING THE CONTROL PANEL
DIGIT SED ELECTRONIC CONTROLLER WITH LCD DISPLAY 1.09.370E 10.01.2007 VALLOX These instructions replace and complement the instructions for use and maintenance of the following VALLOX units: VALLOX DIGIT
More informationRC-CDTO. Pre-programmed room controller with display, communication and three-point control
revision 02 2016 RC-CDTO Pre-programmed room controller with display, communication and three-point control RC-CDTO is a complete pre-programmed room controller from the Regio Midi series intended to control
More informationWeekday / weekend room temperature controller
s 2 203 Weekday / weekend room temperature controller Heating applications REV17.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display
More informationIS-ZW-RC-1 Remote Control Installation Sheet
GE Security IS-ZW-RC-1 Remote Control Installation Sheet Description Z-Wave technology is designed to automate lighting/home control and provides easy remote operation of all your Z-Wave enabled devices.
More informationProduct and Applications Description. Example of Operation. Installation Instructions WARNING. Note. Application Programs
Product and Applications Description Example of Operation dimmer UP 525/11 load circuit AC 230 V L1 N The dimmer UP 525/11 is a dimming actuator for mounting in box mounts (a.o. 60 mm Ø, 60 mm depth).
More informationUsing the application program. Functional description. GAMMA instabus Application Program Description. October Event Module 800A06
Using the application program Product range: Product type: Manufacturer: Controllers Controllers Siemens Name: Event Module N 341 Order No.: 5WG1 341-1AB01 Functional description With the help of a special
More informationGVS K-BUS R KNX/EIB Push Button Sensor Contents 1. Summary
Guangzhou Video-star Electronics Industrial Co., Ltd K-BUS R Push Button Sensor User manual-ver. 1.1 CHKP-01/01.1.xx CHKP-02/01.1.xx CHKP-03/01.1.xx KNX/EIB Intelligent Installation Systems GVS K-BUS R
More informationRVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting
G2522en Heating controller Installation Instructions RVL470 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a
More informationCS2000 Automatic control V3 Quick Guide
112626E-03 2017-09 CS2000 Automatic control V3 Quick Guide ! All electrical connections must be made by an expert. 2 Contents! This quick guide only applies to software version V3.x To view current software
More informationCommunicative controller for VAV systems
FCR015 Communicative controller for VAV systems Summary FCR015 is a communicative controller for heating and cooling panels and a VAV (variable air volume) damper. It measures temperature and CO 2 concentration
More informationUse of the application program
Use of the application program Product family: Product type: Manufacturer: Display Display units Siemens AG Name: Contouch Room Controller UP 204 Order no.: 5WG1 204-2AB11, titanium white, 5WG1 204-2AB21,
More informationStructure of the device. Push-button sensor module. Ref.-no.: 4008 TSM Safety instructions
Push-button sensor module Ref.-no.: 4008 TSM Safety instructions Caution! Electrical devices may only be installed and fitted by electrically skilled persons. Non-compliance with the installation information
More informationOperating and mounting instructions
General Usage IPAS DALI Gateways bring together the crossfunctional KNX installation bus and the lighting control specific DALI-Bus (IEC 60929). Lights with cost-effective, digital DALI ECGs can therefore
More informationDuoFern Multiple Wall Controller
DuoFern Multiple Wall Controller 9494-1 Instruction manual for the electrical connection and for commissioning Item no. 3250 19 74 / Type: 9494-1 (surface-mounted with battery) VBD 663-2 (12.16) Dear Customer,
More information7-day room temperature controller
s 2 208 7-day room temperature controller Heating applications REV34.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display and large
More informationSTRA-17 Room controller. Installation and maintenance manual. Content
Content Installation preparations... Wiring diagram...3 Display handling...5 Technical data...6 Configuration...7 Operating modes...7 Controller modes...7 Activation operating modes...7 Control states...8
More information7-day room temperature controller
s 2 205 7-day room temperature controller Heating or cooling applications REV24.. Mains-independent, battery-operated room temperature controller featuring user-friendly operation, easy-to-read display
More information1 Safety instructions. 2 Device components. 3 Function. IC00P01DAL - DALI gateway. DALI gateway. Operating instructions
DALI gateway Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property damage possible. Please
More informationPre-programmed room controller with display and communication
revision 01 2014 RC-C3DOC Pre-programmed room controller with display and communication RC-C3DOC is a complete pre-programmed room controller from the Regio Midi series intended to control heating, cooling
More informationRoom Temperature Controller with 7-Day Time Switch, LCD and opt. Remote Temperature Sensor
3 036 Room emperature Controller with 7-Day ime Switch, LCD and opt Remote emperature Sensor for heating systems RDE201 2-position control with ON/OFF output for heating Operating modes: normal operation
More informationZEITSCHALTUHR TIMER SWITCH TIJDSCHAKELKLOK KOPPLINGSUR RELOJ TEMPORIZADOR IDŐZÍTŐ KAPCSOLÓ ΧΡΟΝΟΔΙΑΚΟΠΤΗΣ DZ 20-A V2
DZ 20-A V2 ZEITSCHALTUHR Bedienungs- und Sicherheitshinweise TIJDSCHAKELKLOK Bedienings- en veiligheidsinstructies TIMER SWITCH Operation and Safety Notes KOPPLINGSUR Bruksanvisning och säkerhetsanvisningar
More informationQMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74 QMX3.P37. Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode
s 1 602 QMX3.P37 QMX3.P34 / P74 QMX3.P02 QMX3.P70 QMX3.P30 Desigo TRA Wall-mounted sensors and room operator units for KNX PL-Link, KNX S-mode and KNX LTE-Mode QMX3.P30 QMX3.P70 QMX3.P02 QMX3.P34 QMX3.P74
More informationProduct documentation
Product documentation KNX Room controller display compact module ALBRECHT JUNG GMBH & CO. KG Volmestraße 1 D-58579 Schalksmühle Telefon: +49.23 55.8 06-0 Telefax: +49.23 55.8 06-1 89 E-mail: mail.info@jung.de
More informationKNX S-B4T-UP. Actuator for 230 V or 24 V. Installation and Adjustment
EN KNX S-B4T-UP Actuator for 230 V or 24 V Installation and Adjustment 1 Content 1. Description... 3 1.1. Technical data... 3 1.2. Structure... 4 1.2.1. Structure 230 V AC version... 4 1.2.2. Strucure
More informationRCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs
revision 04 2016 RCF-230CAD Room controller with communication for fancoil applications with two analogue 0...10 V DC outputs Intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint
More informationSmart Touch Thermostat Colour Touchscreen Thermostat
OBSMART Smart Touch Thermostat Colour Touchscreen Thermostat INTRODUCTION Orbry Smart Touch Thermostat The Orbry Smart Touch Thermostat is a digital thermostat, which is designed for electric underfloor
More informationApplication description
Hersteller Berker Taster ETS Multifunktions-Tastsensor 1-4fach Application description 1-fold KNX multifunctional push-button 2-fold KNX multifunctional push-button 3-fold KNX multifunctional push-button
More informationSemi flush-mounted room temperature controllers with LCD
s 3 077 RDD310 RDE410 Semi flush-mounted room temperature controllers with LCD For heating systems RDD310 RDE410 RDD310 and RDE410 features: Operating voltage AC 230 V 2-position control with On / Off
More informationProduct and Applications Description. Application Programs. Note. instabus EIB Technical Product Information. June 2005
Product and Applications Description Application Programs The application programs of the dimmer UP 525/01 consist of two elements: the actuating and the sensor program element. The tasks actuating program
More informationConnections, displays and operating elements. Hand 1 / / 4
GB Blind actuator REG-K/4x24/6 with manual mode Operating instructions Hand Connections, displays and operating elements I H 1 2 1 2 1 2 1 2 Hand 3 4 3 4 3 4 3 4 B A C D E ½ CAUTION The blind actuator
More informationclick DuoFix screwless Plug-in screwless terminal NC contact Test tap
307098 Time switch installation EN Astro Time Switch SELEKTA 170 top2 1700100 1. Basic safety information WARNING Danger of death from electric shock or fire! ¾Installation shold only be carried ot by
More information