STYX network. Electronic scoring systems. Installation Start-up Function control / updates / support

Size: px
Start display at page:

Download "STYX network. Electronic scoring systems. Installation Start-up Function control / updates / support"

Transcription

1 Start-up Function control / updates / support SIUS AG Im Langhag 1 CH-8307 Effretikon Switzerland Phone info@sius.com

2 Table of contents STYX/LON hybrid network overview 3 Description and connectors of components 4 8 STYX cables 9 Target line 10 Lane scoreboards 11 Firing line 12 Segment control (10-Lane-Command-Desk) 13 Control room 14 Rack SR01 structure and cabling Page Start-up - pending 18 Function control / updates / support - pending Table of contents 2

3 overview Segment with 20 lines Weitere Lane Scoreboards Weitere Segmentkontrolle Legend LON 110V 240V LON-Backbone USB Ethernet STYX Target line Firing line Lane scoreboards Segment control Control room STYX/LON hybrid network 3 overview

4 components Pos. 1 SNC01 connector The connector connects maximally 5 devices (targets or lane scoreboards) with the network. The installation should be made at an easily accessible place protected from ammunition fragments (e.g. in a cable duct) in the middle of the devices to be connected. In a STYX segment maximally 4 SNC01 connectors (for 20 devices) can be linked together. Following STYX segments must be connected separately direct to the rack in the control room. SPS01 Power supply (48V) STYX device 1 STYX device 2 STYX device 3 STYX device 4 STYX device 5 Do not remove the existing protective covers of unused channels. From SNC02 connector (rack/control room) or previous SNC01 connector To next SNC01 connector Control lamps Pos. A1.1 SPS01 power supply for connector Power supply for SNC01 connector and devices connected to it, equipped with a country-specific device plug and a corresponding connection cable. Link (green) = connection with device Device plug (power supply) Max (orange) = max. data speed Err (red) = error On (green) = power To SNC01 STYX network connector Pos. Article no. Description components 1 SNC01 connector (for max. 5 targets resp. lane displays), Dimensions (WxHxD): 283x41x43mm, Weight: 0,5kg 1.1 SPS01 Power supply for connector 48V/5A, Dimensions (WxHxD): 220x40x68mm, Weight: 1,3kg Country-specific power supply cable > AA1** components 4 Description and connectors

5 Pos. 2 STE01 adapter STYX to ethernet Pos. 3 STL01 converter STYX to LON This adapter enables the connection of printers resp. PC s/laptops to the STYXnetwork. The converter is the interface from the STYX to the LON network. By using it, devices, which only have a LON connector can be integrated in the network. Connector Control lamps Connector ethernet (to printer/ PC/laptop) Watchdog (green) = function monitoring Wink (green) = device identification Link (green) = connected to LON network LON connector STYX connector ACT (orange) = communication activity Pos. 4 SLS01 STYX lane scoreboard The SLS01 STYX lane scoreboard receives the data of the according lane and sends those as a video signal to the connected screen TV. LON connector (not in use) STYX connector (from SNC01 connector) HDMI (to connected screen TV) Pos. Article no. Description components 2 STE01 Adapter STYX to Ethernet, Dimensions (WxHxD): 69x44x40mm, Weight: 0,2kg 3 STL01 Converter STYX to LON, Dimensions (WxHxD): 205x53x160mm, Weight: 0,6kg 4 SLS01 STYX lane scoreboard incl. dowels/screws for wall mounting, Dimensions (WxHxD): 205x53x160mm, Weight: 0,6kg components 5 Description and connectors

6 Pos. 5 SR01 Rack 19" master, connector, server and the optional UPS (uninterruptible power supply) can be placed in the rack. The rack is equipped with removable side panels on both sides which enables easy access, even with already mounted devices. The rack has openings on top, bottom and in the rear for cable routing. The cover plates can be broken out. top rear bottom Mounting to a wall: In the rear the rack is equipped with a mounting bracket, which enables the mounting to a wall. The mounting bracket is fixed with screws to the rack. These must be removed from inside of the rack. The mounting bracket can be removed now. It can be mounted with screws and dowels at the required height to the wall. The rack can be hooked up to the mounting bracket on the wall. Finally affix it with the screws from inside of the rack. Pos. Article no. Description components 5 SR01 Rack 19" incl. 6 way power distribution cable, Dimensions (WxHxD): 600x450x505mm, Weight: 16kg Country-specific power supply cable > AA1** components 6 Description and connectors

7 Pos. 5.1 SNC02 connector 19" The SNC02 connector 19" is placed in the rack and establishes the connection with all used STYX devices in the network. If not enough free channels are available, further SNC02 connectors can be connected. STYX segments (of 20 targets / lane scoreboards) must be connected in ascending order, i.e. STYX segment 1 (1 20) > STYX segment 2 (21 40) > STYX segment 3 (41 60) etc. Opening for cable (power supply) from behind Power supply STYX device 1 STYX device 2 STYX device 3 STYX device 4 STYX device 5 From SNM01 master or previous SNC02 connector (rack / control room) To SNS01 server or next SNC02 connector Control lamps: same as SNC01 connector (see page 5). Pos. 5.2 SNS01 server The SNS01 server is placed in the rack. It saves and manages all data and services. PC/laptop (SIUS support) USB STYX connector (to «Out» connector of SNC02 connector) Power supply 110V / 230V Pos. Article no. Description components 5.1 SNC02 STYX-Network-Connector 19" inkl. Montageschrauben/-muttern, Masse (BxHxT): 482x43x220mm, Gewicht: 2kg 5.2 SNS01V2 server «Infrastructure» (Infrastruktur) incl. mounting screws/nuts Dimensions (WxHxD): 482x43x220mm, Weight: 1,5kg SNS01V3 server «Themelia» (Scheiben) incl. mounting screws/nuts Dimensions (WxHxD): 482x43x220mm, Weight: 1,5kg SNS01V4 server «Kanopus» (Lane Score Boards) incl. mounting screws/nuts Dimensions (WxHxD): 482x43x220mm, Weight: 1,5kg SNS01V1 server (spare, unconfigured) incl. mounting screws/nuts Dimensions (WxHxD): 482x43x220mm, Weight: 1,5kg Country-specific power supply cable > AA1** components 7 Description and connectors

8 Pos. 5.3 SNM01 STYX-Network-Master The SNS01 master is placed in the rack. It manages the network and the adressing of the devices. The ethernet connector enables the access to the internet. PC/Laptop (SIUS support) Ethernet (internet access) Actually not in use STYX connector (to «In» connector of SNC02 connector in rack / control room) Power supply 110V / 230V Pos. 5.4 UPS001 uninterruptible power supply (option) We recommend the installation of an UPS001 (needed for ISSF competitions). It secures an uninterruptible power supply for all devices in the rack and protects from data loss. PC/Laptop (SIUS support) Telephone / Overvoltage protection for network Power supply (UPS001) Power supply (to devices) Pos. Article no. Description components 5.3 SNM01 master incl. mounting screws/nuts, Dimensions (WxHxD): 482x43x220mm, Weight: 1,5kg 5.4 UPS001 Uninterruptible power supply (option) 450VA/280W, incl. brackets and mounting screws Country-specific power supply cable > AA1** components 8 Description and connectors

9 KSN001 STYX cables The cables are equipped with a female connector and a male connector. The maximum distance from a network connector to another network connector is 130m (2x65.0m cable). If the distance is larger then 130m, an additional connector must be connected = connector > 2x65.0m cable > connector > required extension cable. 6mm Female Male 15mm The following cables (lengths) are available: KSN STYX cable 0.7m KSN001-2 STYX cable 2.0m KSN001-3 STYX cable 3.0m KSN STYX cable 10.0m KSN STYX cable 20.0m KSN STYX cable 40.0m KSN STYX cable 65.0m components 9 STYX cables

10 target line The cabling of the targets is made according to the illustration below. The targets LS25/50 are equipped with a STYX connection cable, which also provides the power supply STYX cable 2.0m KSN STYX cable 0.7m KSN STYX cable 0.7m KSN STYX cable 2.0m KSN STYX Power supply SPS01 STYX cable 7m KSN001-7 connector SNC01 to connector SNC01 (next 5 lines) STYX cable 65m KSN to connector SNC01 (Segment control / TLCDBOX) 5 targets can be connected to a single connector SNC01. The connector SNC01 should be placed well protected (e.g. in a cable duct) in the middle of these 5 targets. The provided STYX connection cable of the targets is 1,4m long. Depending on the situation, extension cables are needed. The outer targets on either side (1+5 / 6+10 etc.) need an extension cable of min. 2.0m. Both inner targets (2+4 / 7+9 etc.) need an extension cable of min. 0.7m. The individual connectors SNC01 has to be connected. It is possible to connect a maximum of 4 connectors SNC01 to a STYX segment (= 20 targets). and cabling can differ. The according installation plans are relevant. 10 Target line

11 160 (39) lane scoreboards The cabling of the lane scoreboards is made according to the illustration below. The TV screens / HDMI cables are (if not ordered from SIUS) not included in delivery and must be provided by the customer himself TV screen lane scoreboard HDMI cable STYXlane scoreboard SLS01 STYX cable KSN001-L* (L*=length) STYX power supply SPS01 STYX cable 7m KSN001-7 connector SNC01 to connector SNC01 (next 5 lines) STYX cable KSN001-L* (L*=length) to connector SNC02 (rack / control room) 5 STYX lane scoreboards SLS01 can be connected to a single connector SNC01. The connector SNC01 should be placed well protected (e.g. in a cable duct / behind a panel) depending on the situation. The length of the cables depends on the placement of the devices. The individual connectors SNC01 has to be connected. It is possible to connect a maximum of 4 connectors SNC01 to a STYX segment (= 20 lane scoreboards). The first connector SNC01 of a segment has to be connected to the connector SNC02 (rack/ control room). Wall mounting STYX lane scoreboard SLS01 (44.5) (44.5) 54 The device has 2 openings on the bottom side. It can be mounted to a wall with the provided dowels/screws. and cabling can differ. The according installation plans are relevant. 11 Lane scoreboards

12 firing line (control units) The cabling of the SA951 control units is made according to the illustration below. It is a standard LON cabling of 10 control units, which has to be connected with the segment control (10 lane command desk). Terminator KL001-R Y cable KL013 Power supply NT211 LON cable 2m KL LON cable 2m KL T adapter KL001-T LON cable 2m KL Line 1 Line 2 Line 3 Line 4 Line 5 Line 10 Barcode scanner AAG133-80SX LON cable KL001-L* (L*= length) Remote control RC211 Line printer D112-USB-N to segment control (10 lane command desk) and cabling can differ. The according installation plans are relevant. 12 Firing line (control units)

13 segment control (10 lane command desk) The cabling of the segment control is made according to the illustration below. It is a combination of STYX and LON cabling. To control units (firing line) LON cable KL001-L* (L*=lenght) LON cable 1m KL STYX to LON converter STL01 LON cable 1m KL Terminator KL001-R To connector SNC01 (target line) or next TLCDBOX To connector SNC02 (rack/control room) or previous TLCDBOX STYX cable 20m KSN STYX cable KSN001-L* (L*=lenght) Terminator KL001-R Router RTR5000 STYX cable 0.7m KSN STYX to ethernet adapter STE01 connector SNC01 10 lane command desk To next TLCDBOX STYX power supply SPS01 Legend: LON / LTW network Ethernet/USB/HDMI of devices inside the TLCDBOX Devices are cabled according to picture below and then placed in the TLCDBOX. and cabling can differ. The according installation plans are relevant. 13 Segment control (TLCDBOX)

14 control room The cabling of the control room is made according to the illustration below, but can differ depending on the circumstances and the size of the installation. We recommend internet access for broadcasting and support. To segment control (TLCDBOX) LON cable KL001-L* (L*=lenght) Rack 19" SR01 1x master SNM01 3x connector SNC02 3x server 1xSNS01V4, 1xSNS01V3, 1xSNS01V2 STYX to ethernet adapter STE01 STYX cable KSN001-L* (L*=lenght) SNI T-Adapter KL001-T To segment control (TLCDBOX > targets) Segment 01 (01 20) Segment 02 (21 40) Segment 03 (41 60) Segment 04 (61 80) To lane scoreboards Uninterruptible power supply UPS001 4 x STYX cable 4 x KSN001-L* (L*=lenght) 4 x STYX-Kabel 4 x KSN001-L* (L*=lenght) Ethernet cable AA203-L* (L*=lenght) STYX to ethernet adapter STE01 Internet access I-Adapter fem-fem KL001-I Terminator KL001-R Central computer (SIUSDATA/SIUSRANK) Legend: LON / LTW network Ethernet/USB Access to the Internet is provided by the STYX Network Master SNM01. The Ethernet connection of the central computer is exclusively for the (Ethernet DHCP network setting) and is connected via the STE01 adapter. The computer may not be logged in to an additional LAN (e.g. via second Ethernet connection, USB adapter, WiFi etc.). If data exchange between central computer and further devices is requested, it must be done via internet cloud as Dropbox, icloud, GDrive etc., cabling and number of devices can differ. The according installation plans are relevant. 14 Control room

15 Structure and cabling of rack SR01 The rack is delivered assembled (without devices). For wall mounting > see page 6. Screws/nuts/angles for the installation of the devices are included. The side panels can be removed by simultaneously pressing both locking buttoms inwards. Depending on local circumstances the attaching of the door can be changed (left/right side of the rack). The enclosed SIUS sticker can be placed in front on the glass door. If installing the optional UPS001 for an uninterruptible power supply, the mounting angles must be screwed to the bottom rails first. The position of the device should ensure that the glass door of the rack still can be closed. Side view: 4x 8x The mounting rails for the devices are premounted at the 6th hole of the bottom rails. That ensures that in front is sufficient space for cable routing. With the provided screws and nuts the devices can be attached to the mounting rails. The number of required devices depends on the size of the installation. Screw the UPS001 to the mounting angles. Arrangement of devices from top to bottom: 1x SNM01 master 3x SNC02 connector 3x SNS01 server Option: UPS001 uninterruptible power supply 7x 15 Rack SR01 structure

16 top The rack has openings on top, bottom and in the rear for cable routing. The cover plates can be broken out. rear Remove the cover plate of the requested opening ➊ for cable routing. bottom ➋ The cables can be connected according to the illustration. Front view: To modem (control room) for internet access To segment control (TLCDBOX > targets) A B C D To lane scoreboards F G H I 4x 4x A B C D F G H I E K Cables of STYX segments (of 20 targets / lane scoreboards) must be connected in ascending order to the Network Connectors. A > B > C > D > E > F > G > H > I > K etc. It is possible to connect targets and lane scoreboards to the same Network Connector. This must be done in ascending order. Network Server «Kanopus» (Lane Score Boards) To socket Network Server «Themelia» (Targets) Network Server «Infrastructure» (Infrastructure) To printer (control room) To central computer (control room) Power supply from UPS001 Power supply from 6 way distribution cable AA377 STYX cable Ethernet cable (to modem for broadcasting and online support) 16 Rack SR01 cabling

17 Cable routing The 6 way distribution cable A377 for power supply is included. It can be attached with the provided cable tie The cables can be routed/attached according to the examples laterally to the mounting rail. shown below. Geräte Steckdose Rear view (power supply): To socket Power supply from UPS001 Power supply from 6 way distribution cable AA Rack SR01 cabling-

18 Start-up / function control / updates / support pending

19 - 19 -

20 SIUS worldwide There are SIUS representatives all around the globe. Find your local SIUS sales partner here: > contact 20

LS25/50 LASERSCORE. Electronic scoring systems. Installation overview and components. ISSF approval phase 1, 2 and 3

LS25/50 LASERSCORE. Electronic scoring systems. Installation overview and components. ISSF approval phase 1, 2 and 3 ISSF approval phase, 2 and Basic configuration of the target for 25 resp. 50 meters rifle and pistol Installation overview and components SIUS AG Im Langhag CH-807 Effretikon Switzerland Phone +4 52 54

More information

Electronic scoring systems

Electronic scoring systems overview and components sius ag Im Langhag CH-8307 Effretikon Switzerland Phone +4 5 354 60 60 www.sius.com info@sius.com table of contents Installation overview 3 0-LANE-COMMAND-DESK 4 Control room 5

More information

HS10 HYBRIDSCORE. Electronic scoring systems. Installation overview and components. ISSF approval phase 1

HS10 HYBRIDSCORE. Electronic scoring systems. Installation overview and components. ISSF approval phase 1 ISSF approval phase Basic configuration of the target for airguns and small bore rifles Installation overview and components SIUS AG Im Langhag CH-8307 Effretikon Switzerland Phone +4 52 354 60 60 Fax

More information

SIUSLANE. Electronic scoring systems. Low-cost scoring system with PC/Laptop SIUS AG

SIUSLANE. Electronic scoring systems. Low-cost scoring system with PC/Laptop SIUS AG SIUSLANE s tion n a c i l app scriptio e l b i e Poss ction d fun and Low-cost scoring system with PC/Laptop SIUS AG Im Langhag 1 CH-8307 Effretikon Switzerland Phone +41 52 354 60 60 www.sius.com info@sius.com

More information

Electronic scoring systems

Electronic scoring systems Worldwide only 0m laser target with ISSF approval phase, and Installation overview and components Basic configuration of the target for airguns and small bore rifles SIUS AG Im Langhag CH-807 Effretikon

More information

S310. Electronic scoring systems. Installation overview and components. Worldwide only 300m target with ISSF approval phase 1, 2 and 3

S310. Electronic scoring systems. Installation overview and components. Worldwide only 300m target with ISSF approval phase 1, 2 and 3 Worldwide only 300m target with ISSF approval phase, 2 and 3 Installation overview and components Basic configuration of the target for big bore rifles (ISSF 300m) SIUS AG Im Langhag CH-8307 Effretikon

More information

HS10 HYBRIDSCORE. Single Lane 10m. SIUS AG Im Langhag 1 CH-8307 Effretikon Switzerland Phone

HS10 HYBRIDSCORE. Single Lane 10m. SIUS AG Im Langhag 1 CH-8307 Effretikon Switzerland Phone SIUS AG Im Langhag 1 CH-8307 Effretikon Switzerland Phone +41 52 354 60 60 www.sius.com info@sius.com HS10 HYBRIDSCORE Mounting height = 1.537m ± 0,05m Target HS10 without digital display Target holder

More information

Quick start guide for i5 520 ( or )

Quick start guide for i5 520 ( or ) Quick start guide for i5 520 (9405-520 or 9406-520) 1 Before you begin This Quick start guide contains an abbreviated set of setup instructions designed to help you quickly unpack and set up a standard

More information

350 East Plumeria Drive San Jose, CA USA February

350 East Plumeria Drive San Jose, CA USA February Installation Guide 350 East Plumeria Drive San Jose, CA 95134 USA February 2013 201-15135-03 Support Thank you for selecting NETGEAR products. After installing your device, locate the serial number on

More information

Emporio EPoS Setup Guide

Emporio EPoS Setup Guide Emporio EPoS Setup Guide Contents Hardware Dell Optiplex GX520 PC Vibrant Touch Screen Monitor Epson TM-T88IV Receipt Printer DigiPOS Cash Drawer inc Cable Pole Display Symbol LS9203 Scanner Belkin Surge

More information

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays

Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40 - 55 flat Panel Displays Installation and Assembly: 2 x 2 Video Wall Ceiling Mount for 40" - 55" flat Panel Displays Model: DS-VWT955-2X2 EXTENSION COLUMN (SOLD SEPARATELY) COMPATIBILITY Display width must be a minimum of 36"

More information

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions

1 Safety instructions. 2 Device components. 3 Function. Smart Control IP. Art. No. SC 1000 IP. Operating instructions Smart Control IP Art. No. SC 1000 IP Operating instructions 1 Safety instructions Electrical equipment may only be installed and fitted by electrically skilled persons. Serious injuries, fire or property

More information

KVM Accessories 7.5 G&D IF IT S KVM. KVM Accessories. Space-saving fasteners for rack mounting

KVM Accessories 7.5 G&D IF IT S KVM. KVM Accessories. Space-saving fasteners for rack mounting KVM Accessories Space-saving fasteners for rack mounting G&D IF IT S KVM The company Guntermann & Drunck is regarded as a leading manufacturer of digital and analogue KVM equipment used in control rooms

More information

Floor Standing Pedestal

Floor Standing Pedestal 2336 K052 Floor Standing Pedestal Kit Instructions Issue C Revision Record Issue Date Remarks A Feb 20021 First issue B June 2007 Added pedestal floor bolting procedure C Mar 2011 Added Universal Mounting

More information

RittalXpress TS IT Enclosure Assemble-to-Order Program

RittalXpress TS IT Enclosure Assemble-to-Order Program RittalXpress TS IT Enclosure Assemble-to-Order Program DESIGN YOUR DATA CENTER BY THE NUMBERS. Count down to success: 4, 3, 2, 1... Complete four easy steps, your order can be shipped in three days and

More information

Digital Menu Board Wall Mount Installation Instructions

Digital Menu Board Wall Mount Installation Instructions Digital Menu Board Wall Mount Installation MDSWMB2T4249 MDSWMB3T4249 www.microndisplaysolutions.com Table of Contents Important Safety... 3 Models and Specifications... 4 Package Contents... 5 Step 1 Two(2)

More information

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing

D-Net CABINETS. D-Net cabinets are a versatile racking system suitable for housing D-Net CABINETS D-Net cabinets are a versatile racking system suitable for housing networking and various structured cabling components. D-Net Cabinets are manufactured in Taiwan in compliance with ISO9001:2000

More information

M1034W Engineering Workstation

M1034W Engineering Workstation M1034W Engineering Workstation Container Contents Included in container The list below shows components included in an M1034W Engineering Workstation container. M1034W Engineering Workstation Chassis mounting

More information

MAGIXBOX TM. Quick Start Guide

MAGIXBOX TM. Quick Start Guide TM TM by TouchMagix MAGIXBOX TM Quick Start Guide What s in the box: Ankle Ceiling Plate Extendable Rod Connector Piece Middle Piece Universal Spider Super clamp with ball socket Safety Cable Projector

More information

Quick start guide for p5 520 ( )

Quick start guide for p5 520 ( ) Quick start guide for p5 520 (9111-520) 1 Before you begin This Quick start guide contains an abbreviated set of setup instructions designed to help you quickly unpack and set up a standard system. Users

More information

The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse

The list below shows items not included with a SmartVDI-110 Server. Monitors Ethernet cables (copper) Fiber optic cables Keyboard and mouse SmartVDI-110 Server Quick Start Guide Container Contents Included in container The list below shows components included in a SmartVDI-110 container. SmartVDI-110 Server Chassis mounting rails and hardware

More information

M1032W Engineering Workstation. The list below shows components included in an M1032W Engineering Workstation container.

M1032W Engineering Workstation. The list below shows components included in an M1032W Engineering Workstation container. M1032W Engineering Workstation Container Contents Included in container The list below shows components included in an M1032W Engineering Workstation container. M1032W Engineering Workstation Chassis mounting

More information

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I

Table of Contents. 1 Welcome. 2 Install your Access Point-I. 3 Using the Access Point-I Table of Contents 1 Welcome Introducing the Avaya Wireless LAN 1-1 About the Access Point-I 1-2 Finding Information 1-3 2 Install your Access Point-I Overview 2-1 Verify Kit Contents 2-2 Write Down Product

More information

Intelligent DC UPS Module

Intelligent DC UPS Module Intelligent DC UPS Module 2V/9~36V DC Input, 2V DC Output Uninterruptible Power Supply Module with Diagnostics Features Model Name AUPS-A0 / AUPS-A20 Input Power AUPS-B0 (2V) AUPS-A20 (9~36V) AUPS-B20

More information

Dell Venue 11 Pro Bundle

Dell Venue 11 Pro Bundle One Blue Hill Plaza, 16 th Floor, PO Box 1546 Pearl River, NY 10965 1-800-PC-AMERICA, 1-800-722-6374 (Voice) 845-920-0800 (Fax) 845-920-0880 Dell Venue 11 Pro Bundle This document provides step-by-step

More information

Installation guide. for Cisco TelePresence MX700 Dual Camera mounted on the wall

Installation guide. for Cisco TelePresence MX700 Dual Camera mounted on the wall Installation guide for Cisco TelePresence MX700 Dual Camera mounted on the wall http://www.cisco.com/go/mx-docs This guide covers the MX700 with dual camera, mounted on the wall. Manpower We recommend

More information

KRONOS INSTALLATION INSTRUCTIONS

KRONOS INSTALLATION INSTRUCTIONS INSTALLATION INSTRUCTIONS TABLE OF CONTENTS ENCLOSURE AND DONGLE ASSEMBLY 1 LIGHTED ENCLOSURES 2-10 2 SLIM ENCLOSURE 11-17 3 WIRED-ETHERNET DONGLE 18-25 4 REAR-OFFSET MOUNT 26-33 5 SIDE-MOUNT 34-41 6 SURFACE

More information

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged

15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged 15U Wall-Mount Server Rack Cabinet - 20 in. Deep - Hinged Product ID: RK1520WALHM This 15U server or network rack cabinet lets you mount your EIA-310 compliant equipment to the wall, in a secure enclosure

More information

A. Monitor Settings. 1. Right-Click on the desktop. Select Properties. 2. Change color quality to highest (32bit).

A. Monitor Settings. 1. Right-Click on the desktop. Select Properties. 2. Change color quality to highest (32bit). A. Monitor Settings 1. Right-Click on the desktop. Select Properties 2. Change color quality to highest (32bit). 1 B. Hardware Installation 1. Connector Instruction Open the cover to find the cable connectors

More information

Counting ramp SP User s manual.

Counting ramp SP User s manual. Counting ramp SP2-143 User s manual www.schick-sa.com Table of content 1 Introduction 3 2 LED colours definitions 3 2.1 Normal operating mode 3 3 Installation 3 3.1 Fitting 3 3.2 Connections 3 3.3 Limit

More information

Installation guide. for Cisco TelePresence MX700 Dual Camera on a free standing floor stand or a floor stand secured to the wall

Installation guide. for Cisco TelePresence MX700 Dual Camera on a free standing floor stand or a floor stand secured to the wall Installation guide for Cisco TelePresence MX700 Dual Camera on a free standing floor stand or a floor stand secured to the wall http://www.cisco.com/go/mx-docs This guide covers the floor stand mounted

More information

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description

ME PLC Multifunctional housing for complex electronics. Data sheet _en_01. 1 Description Multifunctional housing for complex electronics Data sheet 105504_en_01 PHOENIX CONTACT 2013-04-08 1 Description The housings of the ME PLC 40... product group consist of a 40-mm wide housing base with

More information

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation

Installation Manual. Mounting Instructions Mechanical Mounting. Luminato. Teleste Corporation Luminato Installation Manual Teleste Corporation Mounting Instructions Mechanical Mounting Luminato Mechanical Installation, agile_59300316, rev0044 Introduction 1 Contents Introduction 4 General... 4

More information

350 East Plumeria Drive San Jose, CA USA May

350 East Plumeria Drive San Jose, CA USA May Installation Guide 350 East Plumeria Drive San Jose, CA 95134 USA May 2012 201-15135-02 NETGEAR, Inc. All rights reserved. No part of this publication may be reproduced, transmitted, transcribed, stored

More information

19" TiRAX cabinet system. from page 3. 19" NETcell cabinet system from page 31. Open 19" racks from page 43

19 TiRAX cabinet system. from page 3. 19 NETcell cabinet system from page 31. Open 19 racks from page 43 9" TiRAX cabinet system from page 9" NETcell cabinet system from page Open 9" racks from page Wall-mounting/stand-alone distribution systems from page 5 Wall-mounting enclosure systems from page 6 Air

More information

550 and 750 VA a multi-socket UPS to make all your connections easier. Protection adapted to meet all your needs

550 and 750 VA a multi-socket UPS to make all your connections easier. Protection adapted to meet all your needs NeTYS PL 550 and 750 VA a multi-socket to make all your connections easier An innovative solution A compact design, it integrates a larger number of sockets adapted to IT environments, facilitating connection.

More information

LifeSize ClearSea Installation Guide August 2012

LifeSize ClearSea Installation Guide August 2012 LifeSize ClearSea Installation Guide August 2012 LifeSize ClearSea LifeSize ClearSea Virtual Machine LifeSize ClearSea Installation Guide 2 LifeSize ClearSea This guide describes how to install and configure

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server in a rack cabinet, review the following guidelines:

More information

Netfinity White Paper Netfinity Technology Center

Netfinity White Paper Netfinity Technology Center Netfinity White Paper Netfinity Technology Center Rack Storage Expansion Enclosure Planning Guide Abstract This paper is designed for use by Pre-Sales technical marketing representatives. This includes

More information

TASER Axon Dock Installation Manual IMPORTANT SAFETY INSTRUCTIONS

TASER Axon Dock Installation Manual IMPORTANT SAFETY INSTRUCTIONS TASER Axon Dock Installation Manual IMPORTANT SAFETY INSTRUCTIONS Read all warnings and instructions. Save these instructions. The most up-to-date warnings and instructions are available at www.taser.com

More information

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment)

Accessories for control enclosures. BERNSTEIN attachment solutions. Double coupling head (console version with suspension system attachment) 25 Accessories for control enclosures BERNSTEIN attachment Single coupling head (suspended console version) Double coupling head (console version with suspension system attachment) 322.5 231 232 140 The

More information

IBM Systems. Quick start guide for IBM System p5 505 ( )

IBM Systems. Quick start guide for IBM System p5 505 ( ) IBM Systems Quick start guide for IBM System p5 505 (9115-505) 1 Before you begin This Quick start guide contains an abbreviated set of setup instructions designed to help you quickly unpack and set up

More information

All company and product names are or Registered Trademarks of their respective owners.

All company and product names are or Registered Trademarks of their respective owners. Install guide No part of this documentation may be reproduced in any form whatsoever or be stored in any data retrieval system without prior written permission of the copyright owners. This documentation

More information

User Manual. Printer P-52RUE

User Manual. Printer P-52RUE User Manual P-52RUE Overview 3 4 2 5 1 6 13 12 7 11 10 9 8 Overview Table 1 Paper feed button 8 Ethernet RJ45 connection 2 Status indicator 9 USB device connection 3 Paper cutter 10 RS232 connection 4

More information

8/16/32-Ch Network Video Recorder NVR Series

8/16/32-Ch Network Video Recorder NVR Series 8/16/32-Ch Network Video Recorder NVR Series Quick Installation Guide Table of Contents Chapter 1. Introduction...3 1.1 Before Installation...3 Chapter 2. Physical Description and Installation...4 2.1

More information

9. SPARE PARTS -43- STEAM SYSTEM (OPTION ONLY) Steam Switch Water Solenoid

9. SPARE PARTS -43- STEAM SYSTEM (OPTION ONLY) Steam Switch Water Solenoid 9. SPARE PARTS PART NO DESCRIPTION CONTROLS 021473 Switch - Power 024562 Power Relay (From S/N 232054) 024563 Power Relay Upgrade Kit (To S/N 232053) 017121 Thermostat 020823 Knob - Thermostat / Bake Timer

More information

Surveillance Flexibility with GeoVision Wireless Cube IP Cameras

Surveillance Flexibility with GeoVision Wireless Cube IP Cameras Surveillance Flexibility with GeoVision Wireless Cube IP Cameras Applied to Article ID: GV15-13-03-07-l Release Date: 03/07/2013 GV-CBW120 / 220 GV-CAW120 / 220 Introduction Taking advantage of the light

More information

A. Monitor Settings. 1. Right-Click on the desktop. Select Properties. 2. Change color quality to highest (32bit).

A. Monitor Settings. 1. Right-Click on the desktop. Select Properties. 2. Change color quality to highest (32bit). A. Monitor Settings 1. Right-Click on the desktop. Select Properties 2. Change color quality to highest (32bit). 1 B. Hardware Installation 1. Connector Instruction Connect the power adaptor first and

More information

gams Installation Guide gams Environmental Monitoring Ltd. Copyright

gams Installation Guide gams Environmental Monitoring Ltd. Copyright gams Installation Guide gams Environmental Monitoring Ltd. Copyright 2015-2018 Table of Content Preparing for installation Installing monitors Connecting monitors to Internet 1.1 Use pre-flight checklist

More information

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E

Operating Instructions (Compact) SIMATIC. Industrial PC SIMATIC Microbox PC 420. Siemens. Release 11/2006 A5E Operating Instructions (Compact) 1 SIMATIC Industrial PC Release 11/2006 A5E00344128-04 Siemens Safety Guidelines This manual contains notices you have to observe in order to ensure your personal safety,

More information

Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide

Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide Microsoft Azure StorSimple Appliance 8600 Hardware Installation Guide Contents Unpack your device... Prerequisites... Unpacking your device... Rack-mount your device... Site preparation... Prerequisites...

More information

Stripes. 19" Outlet Stripes Desktop Outlet Stripes IP Power Distribution Units IP Monitoring Units UPS...

Stripes. 19 Outlet Stripes Desktop Outlet Stripes IP Power Distribution Units IP Monitoring Units UPS... Stripes 19" Outlet Stripes... 90 Desktop Outlet Stripes... 93 IP Power Distribution Units... 94 IP Monitoring Units... 95 UPS... 96 19" Outlet Stripes DIGITUS 19" outlet strip with switch, 7 outlets DIGITUS

More information

Foreseesons Monitor Installation Instructions

Foreseesons Monitor Installation Instructions Foreseesons Monitor Installation Instructions Visit the Merit Entertainment Web site http://www.meritind.com PM0626-04 Table of Contents Parts List... p. 1 Cabinet Identification... p. 1 Cabinets with

More information

Automated Parking Technologies, LLC

Automated Parking Technologies, LLC The Administration Unit/Pay Station is the central component of Parking Management System 450. Controlled via a central computer, it provides a comprehensive range of functions for monitoring and controlling

More information

Installation guide. for Cisco TelePresence MX700 Single Camera on a free standing floor stand or a floor stand secured to the wall

Installation guide. for Cisco TelePresence MX700 Single Camera on a free standing floor stand or a floor stand secured to the wall Installation guide for Cisco TelePresence MX700 Single Camera on a free standing floor stand or a floor stand secured to the wall https://www.cisco.com/go/mx-docs This guide covers the floor stand mounted

More information

AccuPOS Hardware Setup Guide TABLE OF CONTENTS

AccuPOS Hardware Setup Guide TABLE OF CONTENTS AccuPOS Hardware Setup Guide TABLE OF CONTENTS 1. Receipt Printer (TSP 100) a. Unpacking b. Parts Identification c. Hardware setup and Cable connection d. Software Setup e. Configuring Receipt Printer

More information

HG659 Quick Start Guide. Vodafone Power to you

HG659 Quick Start Guide. Vodafone Power to you HG659 Quick Start Guide Vodafone Power to you Start here if you use Gigabit Broadband 2 Your quick start guide for Gigabit Broadband What s in the box for FIBRE to the building? HG659 router Ethernet cable

More information

EWS660AP. Quick Installation Guide

EWS660AP. Quick Installation Guide Package contents - Managed indoor access point - Power adapter - RJ-45 Ethernet cable - Mounting bracket - Mounting kit - T-Rail mounting kit IP Adress configuration Step 1: Once your computer is on, ensure

More information

Next Generation Firewall

Next Generation Firewall Next Generation Firewall Hardware Guide Models 1101, 1105, 2101, 2105 Revision D Contents Introduction on page 2 Find product documentation on page 2 Series 1100 features on page 3 Series 2100 features

More information

Hardware Installation Guide

Hardware Installation Guide Hardware Installation Guide Congratulations on purchasing a LogLogic ppliance! The LogLogic ppliance-based solution enables you to capture and manage log data from all types of sources in your enterprise.

More information

Rack Installation Instructions

Rack Installation Instructions Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. Before installing your server in a rack cabinet, review the following guidelines:

More information

Hassle-free equipment installation

Hassle-free equipment installation 22U 36in Knock-Down Server Rack Cabinet with Casters StarTech ID: RK2236BKF This server rack provides 22U of storage space in a sleek secure cabinet for storing EIA-310 compliant 19 rackmount devices such

More information

Operating Instructions USM Haller Tables

Operating Instructions USM Haller Tables 1 Introduction 1.1 Type description 1.2 General safety instructions 1. Safety precautions 1.4 Cleaning, water protection 1.5 Clamping protection 1.6 Maximum load 1.7 Storage instructions 1.8 Transport

More information

LD4650 Universal USB-C Dock with K-Fob Smart Lock

LD4650 Universal USB-C Dock with K-Fob Smart Lock LD4650 Universal USB-C Dock with K-Fob Smart Lock Part Numbers: K38401M (Multi-User); UPC Codes: 8589638401 (Multi-User); K38400NA (Single-User) 8589638401 (Single-User) The LD4650P Universal USB-C Dock

More information

LGX Core-NC210: i5 NUC Industrial Computer

LGX Core-NC210: i5 NUC Industrial Computer LGX Core-NC210: i5 NUC Industrial Computer LGX Core-NC210 Features 2.80 GHz Intel Dual Core i5 1 HDMI, 1 USB 3.0 (Front), and 2 USB 2.0 (Back) Intel QS77 Express Chipset Optimized cooling keeps the system

More information

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions

HP UPS R/T3000 G2. Overview. Precautions. Kit contents. Installation Instructions HP UPS R/T3000 G2 Installation Instructions Overview The HP UPS R/T3000 G2 features a 2U rack-mount with convertible tower design and offers power protection for loads up to a maximum of 3300 VA/3000 W

More information

Parts List by Ass y 1. DRYER CBINET ASS Y

Parts List by Ass y 1. DRYER CBINET ASS Y Parts List by Ass y 1. DRYER CBINET ASS Y 9 ASKO, TLS752XXL - Electric dryer #107752PP (TLS752) Pos Spare part No. Description Qty Comment Cabinet C01 3610392900 Base 1 Pc's C01 3612206500 Frame Top -

More information

1. Move the cardboard carton close to the installation site, making sure you have adequate space to remove all the contents of the box.

1. Move the cardboard carton close to the installation site, making sure you have adequate space to remove all the contents of the box. Install the vedge 1000 Router Once you have prepared your site for router installation, unpack the vedge 1000 router. If you plan to install the router in a 19-inch rack, unpack the rack-mount kit as well

More information

Interfaces Service and Field

Interfaces Service and Field Interfaces Service and Field Front Panel Interfaces Interfaces Service Receptacles Cable Entry Systems 02 TRANSFORMATOREN 03 MODLINK MSDD THE CONNECTION TO THE OUTSIDE WORLD A safe bet MARKET REQUIREMENTS

More information

Views of the HC-1021 Series. Front View of HC-1021IR. HC-1021IR/1021P Infotainment Terminal User Manual

Views of the HC-1021 Series. Front View of HC-1021IR. HC-1021IR/1021P Infotainment Terminal User Manual HC-1021IR/1021P Infotainment Terminal User Manual HC-1021IR HC-1021P Package Contents HC-1021 series terminal x1 Power adaptor...x1 Power cord.x1 I/O cable cover (including 2 screws).x1 User manual...x1

More information

ST101-SR Installation Guide

ST101-SR Installation Guide ST101-SR Installation Guide Removing the Chassis Cover 1. Make sure the system and all other peripheral devices connected to it has been powered-off. 2. Disconnect all power cords and cables. 3. The screw

More information

Plug & Play WiFi IP Kit

Plug & Play WiFi IP Kit Page: 1 Plug & Play WiFi IP Kit IP cameras and NVR WiFi Installation manual How to install the system How networking How to insert an additional camera Page: 2 Contents of this handbook The WiFi kit RKK

More information

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443

Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443 Thanks for shopping with Improvements! Lighted Canterbury Christmas Greenery Doorway Arch Item #548443 IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY. PARTS LIST: 2 Metal Plate Stands 5 Greenery

More information

AS7.P CF20 NPT DOCK AS7.P CF20 DPT DOCK AS7.P CF20 NPT DOCK WITH SCREEN LOCK AS7.P CF20 DPT DOCK WITH SCREEN LOCK AS7

AS7.P CF20 NPT DOCK AS7.P CF20 DPT DOCK AS7.P CF20 NPT DOCK WITH SCREEN LOCK AS7.P CF20 DPT DOCK WITH SCREEN LOCK AS7 AS7.P020.100 CF20 NPT DOCK AS7.P020.102 CF20 DPT DOCK AS7.P020.200 CF20 NPT DOCK WITH SCREEN LOCK AS7.P020.202 CF20 DPT DOCK WITH SCREEN LOCK AS7.P020.001 CF20 SCREEN LOCK ARM PANASONIC TOUGHBOOK CF20

More information

Power Focus 4000 Systems

Power Focus 4000 Systems Power Focus 4000 Systems DS DRIVE SYSTEMS 141 Power Focus Controller POWER FOCUS 4000 SYSTEMS Controller hardware: The Power Focus range controls tools from the Tensor S, ST,STR, DS and ETX families. The

More information

ReachFree ID Installation Instructions for Wash Select II. Unitec

ReachFree ID Installation Instructions for Wash Select II. Unitec ReachFree ID Installation Instructions for Wash Select II Unitec www.startwithunitec.com Proprietary Information and Materials of Unitec Inc. Such proprietary information and materials may not be disclosed

More information

Stonesoft Next Generation Firewall. Hardware Guide Models 5201, 5205, Revision C

Stonesoft Next Generation Firewall. Hardware Guide Models 5201, 5205, Revision C Stonesoft Next Generation Firewall Hardware Guide Models 5201, 5205, 5206 Revision C Table of contents 1 Appliance features...3 Model 5201, 5205, and 5206 features... 3 Interface modules...6 2 Precautions...

More information

IPLoA-MESH-AC--W User Guide

IPLoA-MESH-AC--W User Guide IPLoA-MESH-AC--W User Guide Table of Contents 3 Introduction 3 Hardware specification 4 Software feature 5 Interface 6 Mounting 7 Installation of the HomeMesh Network 8 Mesh installation via PDS cable,

More information

S Series Stand Assembly Instructions

S Series Stand Assembly Instructions S Series Stand Assembly Instructions Contents Stand Base Column Transducer holder Magnetic screwdriver, Allen bit & Phillips bit Grommets (4) Allen wrench 8mm Phillips-head screws (4) 12mm Allen-head screws

More information

Model KB 400 Cooling incubators with compressor technology

Model KB 400 Cooling incubators with compressor technology Model KB 400 Cooling incubators with compressor technology The powerful virtuoso in cooling incubators for microorganisms: the KB masters temperature ranges from -5 C to 100 C. The new KB series consumes

More information

Quick Installation Guide

Quick Installation Guide Nextiva HDR 1800 High-Definition Receiver Version 1.0 Quick Installation Guide All users should read the Nextiva HDR 1800 User Guide for complete details on installation, usage and functionality. This

More information

The basic product comes with the IRS5 control board, 3 internal cables, 1 external cable with a 5 volt adapter and a mounting bracket with hardware.

The basic product comes with the IRS5 control board, 3 internal cables, 1 external cable with a 5 volt adapter and a mounting bracket with hardware. Please read these instructions and watch the Installation Video before you proceed with the installation of the PC-IRS5-01. Installation Video: http://youtu.be/os98e32vhb4 The PC-IRS5-01 Infrared Receiver

More information

Limanda. Technical data

Limanda. Technical data Polyamide hand held enclosures for data acquisition, MCR and automation engineering 2 sizes: 270 x 248 x 64 mm to 311 x 281 x 72 mm Large fitting area For installations and command devices mobile and stationary

More information

89SV80/R1200. Mechanical Components. Marshalling rack cubicle with double-sided MTP-Elements. Application. Description. Cubicle

89SV80/R1200. Mechanical Components. Marshalling rack cubicle with double-sided MTP-Elements. Application. Description. Cubicle Module Description Procontrol P Mechanical Components Marshalling rack cubicle with double-sided MTP-Elements 1KGD 400 012 E, Edition 01/2010 89SV80/R1200 Application The marshalling rack cubicle has the

More information

IBM. Rack Installation Instructions

IBM. Rack Installation Instructions IBM Rack Installation Instructions Review the documentation that comes with your rack cabinet for safety and cabling information. When installing your server in a rack cabinet, consider the following:

More information

HG659 Quick Start Guide

HG659 Quick Start Guide HG659 Quick Start Guide The future is exciting. Ready? Your quick start guide for Gigabit Broadband Start here if you use Gigabit Broadband Using Fibre to connect what s in the box HG659 router Ethernet

More information

Table of contents SiusBTS... 3 General...4 Initialization view... 5 Configuration view...6 Exercise view... 8 Main menu File...

Table of contents SiusBTS... 3 General...4 Initialization view... 5 Configuration view...6 Exercise view... 8 Main menu File... SiusBTS User guide Table of contents SiusBTS... 3 General...4 Initialization view... 5 Configuration view...6 Exercise view... 8 Main menu... 11 File...12 Report designer... 13 View...14 User data editor...15

More information

Kit Instructions. Camera (NTSC) and Telephone Handset Upgrade K034 Issue A

Kit Instructions. Camera (NTSC) and Telephone Handset Upgrade K034 Issue A Kit Instructions Camera (NTSC) and Telephone Handset Upgrade 7705-K034 Issue A The product described in this book is a licensed product of NCR Corporation. NCR is a registered trademark of NCR Corporation.

More information

WNVR SERIES. QUICK SETUP GUIDE CONTACT US. PHONE (English & Spanish) WEBSITE

WNVR SERIES.   QUICK SETUP GUIDE CONTACT US. PHONE (English & Spanish) WEBSITE QUICK SETUP UIDE CONTACT US PHONE (English & Spanish) Sales Support 1.866.390.1303, Option 3 9:00 am 6:00 pm EST Monday Friday Technical Support 1.866.390.1303, Option 4 Live Chat 24/7, 365 days a year

More information

Innovative Americans, LLC. HD Media Pack Installation Manual

Innovative Americans, LLC. HD Media Pack Installation Manual Innovative Americans, LLC HD Media Pack Installation Manual Please read this manual before you begin! Your installation will be EASIER and SAFER if you take a few moments to read this document!! Proudly

More information

E4233. English. P-Series. ASUS PC (Desktop Barebone) Installation manual. Download the latest manual from the ASUS website:

E4233. English. P-Series. ASUS PC (Desktop Barebone) Installation manual. Download the latest manual from the ASUS website: E P-Series ASUS PC (Desktop Barebone) Installation manual P P Download the latest manual from the ASUS website: www.asus.com Front/Rear panel features P Front (Close) P Front (Close) Front (Open) Rear

More information

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft

USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP ft USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP - 1000 ft Product ID: SV565UTPUSA The SV565UTPUSA USB VGA KVM Console Extender w/ Serial & Audio Over Cat5 UTP (1000 ft) lets you control a

More information

Havis Integrated Control System Installation Instructions for Standard* Ford Police Interceptor Utility

Havis Integrated Control System Installation Instructions for Standard* Ford Police Interceptor Utility Installation Instructions for Standard* Ford Police Interceptor Utility Does not properly fit instrument panel in an Interceptor Utility with Interior Upgrade Code 65U Upgrade Package Includes: Cloth Seats

More information

modlink msdd Front panel interfaces

modlink msdd Front panel interfaces Tight and with full visibility The connecting mechanism of the Modlink MSDD with integrated locking mechanism allows the components to be used under protection class IP65. This protection class prevents

More information

Rack Mount 17 &19 Console User Manual

Rack Mount 17 &19 Console User Manual Rack Mount 17 &19 Console www.szkinan.com @all right reserved Shenzhen Kinan Technology Co.,Ltd Printing Date:2014/08 Version: V2.0 Description Single port console integrate the monitor, keyboard and mouse

More information

829MA 6 and 829MB 6 Data Mountings

829MA 6 and 829MB 6 Data Mountings Telecommunications Group Section 829 MA6 001 Equipment Issue 1 Third Printing, June 2001 829MA 6 and 829MB 6 Data Mountings CONTENTS PAGE Part 1. GENERAL.............................................................................

More information

Model VD 23 Vacuum drying chambers for non-flammable solvents

Model VD 23 Vacuum drying chambers for non-flammable solvents Model VD 23 Vacuum drying chambers for non-flammable solvents A BINDER vacuum drying oven VD series gently dries materials with homogeneous temperature distribution. The patented expansion shelf technology

More information

4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection

4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection 4-Port Industrial USB to RS-232/422/485 Serial Adapter - 15 kv ESD Protection Product ID: ICUSB234854I Add four extra COM ports to your laptop or desktop computer, quickly and easily. This USB to RS232/422/485

More information

NEC Server Rack Configuration Guide

NEC Server Rack Configuration Guide NEC Server Rack Configuration Guide Introduction This document contains product and configuration information that will enable you to configure your system. The guide will ensure fast and proper configuration

More information

Next Generation Firewall

Next Generation Firewall Next Generation Firewall Hardware Guide Models 1101, 1105, 2101, 2105 Revision E Contents Introduction on page 2 Find product documentation on page 2 Series 1100 features on page 3 Series 2100 features