Ridder Power-Roller RPR User Manual
|
|
- Eileen Lawrence
- 5 years ago
- Views:
Transcription
1 User Manual RPR100-4 Ridder Power-Roller Tel. +31 (0) Fax +31 (0)
2 English Contents Ridder Power-Roller - Parts list RPR Ridder Power-Roller Technical data RPR Duty cycle Limit switch Connection diagram RPR Electrical installation RPR Guiding RPR Tel. +31 (0) Fax +31 (0) info@ridder.com
3 Ridder Power-Roller - Parts list RPR100-4 Tel. +31 (0) Fax +31 (0) info@ridder.com 2
4 Ridder Power-Roller - RPR Tel. +31 (0) Fax +31 (0) info@ridder.com
5 Ridder Power-Roller - RPR100-4 Tel. +31 (0) Fax +31 (0) info@ridder.com 4
6 Technical data RPR100-4 The technical information relating to the RPR100-4 is presented below. Duty cycle The RPR100-4 motor has a duty cycle of 10 minutes (kb=s2 (10min)). After that, it must be allowed to cool to 1 C above room temperature. Limit switch The RPR100-4 is switched off by means of the built-in linear limit switch. The linear limit switch used to switch off the RPR100-4 must not be connected directly to the motor. A separate linear limit circuit must be added to the circuit (see electrical circuit diagram, page 14). If the motor and linear limit switch are connected in such a way that the "wrong end" of the linear limit switch is connected up, connection wires 4 and 8 (on the junction box) need to be switched round. 5 Tel. +31 (0) Fax +31 (0) info@ridder.com
7 RPR Power Roller: Wiring Diagrams On the page that follows a wiring diagram for the RPR PowerRoller roller-screen drive-unit is shown. Certain codes are given beside the symbols used in the diagrams. A more complete description of these codes is given in the table below Symbol Description CB Control box with switch components EM Electric motor ES11, ES12 RSU limit switch duty switches ES21, ES22 RSU limit switch system safety switches F1 Fuse K11 Auxiliary relay for mains power cut-out (safety switches) K11/1, K11/2 Auxiliary contact K11 K21, K22 Reversing relay for rotation direction (3-phase) L1, L2, L3 Power source N Neutral conductor P21/1, P22/1 Auxiliary contacts for K21 and K22, electrical safeguard for reverse switching P71, P72 Contacts for automatic control (open or closed) PE Earth contact Q41 Motor protection switch (with Dahlander for low speed) Q41/1 Auxiliary contact Q41 RSU Limit switch S11 Manual switch (bypasses protection circuit) S111 Manual switch Stop - Open - Close - automatic S211 Manual switch U1 Safety transformer (compliant with EN 61558)
8 RPR Power Roller: Wiring Diagrams RPR PowerRoller 3-phase Wiring diagram for RPR PowerRoller with a 3-phase electric motor (type A). Reversing rotational direction RPR PowerRoller: Exchanging the two phases on the electric motor connection strip. Reversing direction of limit switch system: Exchanging the connectors 1 and 7 in connector block for the RSU end switch. Current strength (I) in the switch circuit: This should have a value between 45mA and 130mA (24V-AC).
9 Electrical installation The connection or installation of electronic components may only be made by a qualified electro technician. Guiding RPR100-4 The guiding consists of a tube with a bend at the bottom which allows for the Ridder Power-Roller to tilt away. This guide tube is attached to the base of the greenhouse and/or the girder by means of brackets. The tube is 52 mm shorter than the height of the girder (see dimensional sketch, page 8). In view of the fact that a precise length is essential for the proper operation of the Power-Roller, it needs to be made to measure on site, with the aid of a pipe cutter, for example. Precision is required for the fixing of the mounting brackets to the base of the greenhouse and to the girder. A distance of 80 mm needs to be kept between the column and the back of the mounting bracket. There is a margin of -4 to +2 mm, in connection with the swinging out of the RPR100-4 when following the bend in the guiding. The heart of the guide tube must be mounted at least 75 mm out of the column to ensure that the cable protection can be mounted independently. 7 Tel. +31 (0) Fax +31 (0) info@ridder.com
10 3 Tel. +31 (0) Fax +31 (0)
11 , Tel. +31 (0) Fax +31 (0) info@ridder.com
12
13 Ridder Aandrijfsystemen BV Postbus AJ Harderwijk (NL) Lorentzstraat AX Harderwijk (NL) Telefoon +31 (0) Telefax +31 (0) Internet
MX1 Reversible AC Motor Controller. Supplementary Wiring Examples
MX1 Reversible AC Motor Controller Supplementary Wiring Examples DANGER Electrocution Hazard! Ensure all power is disconnected before servicing or wiring. Install all electrical equipment and wiring in
More informationEM2020 Selectable AC transducer A (UK)
Installation and start up instructions EM2020 Selectable AC transducer 4189300016A (UK) Watt or var transducer Supply and measuring voltage up to 690V Configuration via PC-interface possible FAGET 35 mm
More informationHydroGuard 4 to 20 ma Output Module. For use with HydroGuard Water Quality Monitor and Controller
HydroGuard 4 to 20 ma Output Module For use with HydroGuard Water Quality Monitor and Controller Technician's Manual Installation, Operation, and Maintenance Guide Chapter 1: Preface... 3 1.1 Intended
More informationSupplementary manual UVR16x2E-DE/NP Relay versions
Technische Alternative RT GmbH A-3872 Amaliendorf, Langestr. 124 Tel +43 (0)2862 53635 mail@ta.co.at UVR16x2E-DE UVR16x2E-NP Manual vers. 1.4 EN Supplementary manual UVR16x2E-DE/NP Relay versions Table
More informationMagnetically Actuated Safety Interlock Switches
Rev. 7.07 C US Conforms to EN1088, EN292, EN6020-1 CSA approved MA Series Magnetically Actuated Safety Interlock es Large selection choose from a large selection of contact configurations housed in plastic
More informationInstruction Manual. M Pump Motor Controller. For file reference, please record the following data:
Instruction Manual M Pump Motor Controller For file reference, please record the following data: Model No: Serial No: Installation Date: Installation Location: When ordering replacement parts for your
More informationRako RAK4-R Instruction Manual
Rako RAK4-R Instruction Manual Before Attempting To Program A System Refer To One Of The Following Documents : RAK4 Wireless System Setup Guide (Systems Controlled By An RxLink) Wired System Programming
More informationSafety Contacts: AC models MA-1 thru 5, 10, 12, 13, 16 1 N/C MA-13, 16, 21 2 N/C DC models MA-12, 13, 14, 16 1 N/C MA-13, 15, 16, 20, 21 2 N/C
r Safety Interlock Switches MA Series MA Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic to satisfy most application
More informationMagnetically Actuated Safety Interlock Switches
Conforms to EN10, EN292, EN020-1 CSA and BG approved Actual Size Magnetically Actuated Safety Interlock Switches Large selection choose from a large selection of contact configurations housed in plastic,
More informationNokeval. FD100 series. User Manual
Nokeval FD100 series User Manual Contents Document information... 2 FD100A4 and FD100A6 field displays... 3 Power supply connection... 4 Configuring... 5 Specifications... 7 Document information Device
More informationRLD Software Download Original Instruction
Lorentzstraat 32 3846 AX Harderwijk PO Box 360 3840 AJ Harderwijk the Netherlands T +31 (0)341 416 854 F +31 (0)341 416 611 I ridder.com E info@ridder.com Instruction RLD Software Download Original Instruction
More informationOperating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage
Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling
More informationCI-tronic Reversing contactor Type RCI
Data sheet CI-tronic Reversing contactor Type RCI RCI reversing contactors are designed for demanding forward/reverse control of three-phase AC motors. The zero cross switching method ensures very fast
More informationKNX/EIB KNX Blind actuator. 1 Safety instructions. 2 Device components. Blind actuator 4-gang 24 V DC Order-No. :
Blind actuator 4-gang 24 V DC Order-No. : 2154 00 Blind actuator 4-gang 230 V AC Order-No. : 2160 00 Blind actuator 2-gang 230 V AC Order-No. : 2152 00 Blind actuator 4-gang 230 V AC Order-No. : 1039 00
More informationPositive-guided relay outputs: 4 safety contacts (N/O), instantaneous
ohne Abbildung Contact expansion module for increasing the number of available contacts Approvals PZE X4.1P with universal power supply Unit features Positive-guided relay outputs: 4 safety contacts (N/O),
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL August 2016 This product is designed and manufactured by: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Phone: +31 (0)30 2411901 Fax: +31
More informationVariable Area Flowmeters Installation Instructions G Series and M Series
Variable Area Flowmeters Installation Instructions G Series and M Series Safety Definitions Potential danger to life or of serious injuries. Potential for personal injury from electrical shock. Safety
More informationFor full product information, visit Use the SpeedSpec code or scan the QR Code for quick access to the specific web page.
R Safety Interlock Switches MA Series MA For full product information, visit www.sti.com. Use the SpeedSpec code or scan the QR Code for quick access to the specific web page. Magnetically Actuated Safety
More informationEMM 3-24DC/500AC-16-IFS
Extract from the online catalog EMM 3-24DC/500AC-16-IFS Order No.: 2297523 Electronic motor management with integrated current transformers up to 16 A - active power measurement for overload and underload
More informationBS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL
BS 181 SINGLE CHANNEL POWER SUPPLY USER MANUAL Issue 2011 ASL Intercom BV DESIGNED & MANUFACTURED BY: ASL Intercom B.V. Zonnebaan 42 3542 EG Utrecht The Netherlands Tel: +31 (0)30 2411901 Fax: +31 (0)30
More informationUSER MANUAL INSTALLATION MANUAL. Isolation transformers. ITR Isolation Transformer 7000 W 230V/32A
USER MANUAL INSTALLATION MANUAL Isolation transformers ITR000702000 Isolation Transformer 7000 W 230V/32A Victron Energy B.V. The Netherlands General phone: +31 (0)36 535 97 00 Customer support desk: +31
More informationThe JODEL Piglet System Installer s Manual
The JODEL Piglet System Installer s Manual O Donnell Enterprises Ltd Tierlahood, Stradone, Co Cavan, Ireland Phone 00353 (0)49 4330088 Fax 00353 (0)49 4330200 Mobile 00353 (0)86 2597617 E mail jodelpad@eircomnet
More informationMBP68300 SERIES. AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters. BPU69000 Dual External static switch Plug-in unit
MBP68300 SERIES AC-distribution, Static Switch and Manual Bypass for DAC60000 Dual Inverters Modular Construction AC-distribution 3pcs of MCBs Manual bypass switch BPU69000 Dual External static switch
More informationDatasheet - SRB 402EM-24V
Print - Create PDF - Create EXCEL file 20.04.2011-18:31:35h Datasheet - SRB 402EM-24V Output expanders / SRB 402EM Expander module for contact expansion 4 safety contacts, STOP 0 2 Signalling outputs (Minor
More informationF3ET Lightcurtain in robust aluminium housing
Lightcurtain in robust aluminium housing FET Lightcurtain in robust aluminium housing The FET lightcurtains provide a reliable area monitoring in a robust housing. The M2 -pin connectors and optical synchronisation
More informationOPERATING INSTRUCTIONS PA AMPLIFIER P-1812
OPERATING INSTRUCTIONS PA AMPLIFIER P-1812 Please follow the instructions in this manual to obtain the optimum results from this unit. We also recommend that you keep this manual handy for future reference.
More informationOrdering Key. Type Rated Operational Rated operational Control Voltage Uc Options
otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and
More informationpointofsale available at your local trade outlet
pointofsale available at your local trade outlet pointofsale products IP65 pushbuttons Ø22.5mm Contact rating @ 240V AC 10A Resistive (AC1), 6A (AC15) PB01C PB02C PB03C PB04C PB05C PB06C PB07C PB08C PB09C
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Unit features Positive-guided relay outputs: 7 safety contacts (N/O), instantaneous 2 auxiliary contacts (N/C),
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons, safety gates and light barriers. Approvals Block diagram Unit features Positive-guided relay outputs: 6 safety contacts (N/O), instantaneous 4 auxiliary
More informationAUTOMATE AC MECHANICAL LIMIT TUBULAR MOTOR
AUTOMATE AC MECHANICAL LIMIT TUBULAR MOTOR MECHANICAL LIMIT QUIET OPERATION AUTOMATE mechanical limit AC motors come in 35mm and 45mm diameters with various torque and speeds, including models with Quiet
More informationDatasheet - ZR Z
Print - Create PDF - Create EXCEL file 21.04.2011-16:57:42h Datasheet - ZR 236-11Z Position switch / 236 thermoplastic enclosure - DIN EN 50047 with Actuator / 236 Roller plunger R thermoplastic enclosure
More informationSIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY (PART NO. 8890) INSTALLATION INSTRUCTIONS
SEE SAFETY WARNING ON PAGE 6 SIAC-PS 3G SIGNAL ISOLATOR WITH POWER SUPPLY IS DESIGNED TO BE USED WITH KBAC 3G SERIES DRIVES ONLY KBAC 3G SERIES MODELS CONTAIN THE "(3G)" DESIGNATOR ON THE PRODUCT LABEL
More informationCompact Coded Magnetic Safety Interlock Switch and Control Units
C Conforms to EN292, EN60204-1, EN954-1, EN1088, EN60947-5-3, EN947-5-3, EN50081, EN50082, EN61000-6-2 UL and C-UL listed, TUV certified Description R US Compact Coded Magnetic Safety Interlock Switch
More informationRated operational Control Voltage Uc Supply Voltage Connection Rated operational current 40 C voltage Ue Us 25A AC-53a 32A AC-53a
otor Controllers AC Semiconductor otor Controller Type RSHR 3-Phase Soft starting and stopping of 3-phase squirrel cage motors Control of all 3 phases In Line or In Delta motor connection Low inrush and
More informationOccupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE
Occupancy and Vacancy Sensors ROOM CONTROLLER* DAYLIGHT SENSOR WPP-INT INSTALLATION GUIDE 2 Part Number: WIR-3110 WARNING! SYSTEM MUST BE INSTALLED IN ACCORDANCE WITH LOCAL AND NATIONAL ELECTRICAL CODES
More informationDatasheet - AZ 15 ZVRK
24.12.2015-09:51:40h Datasheet - AZ 15 ZVRK Safety switch with separate actuator / AZ 15 Preferred typ Thermoplastic enclosure Double-insulated Long life 52 mm x 75 mm x 30 mm Multiple coding Large wiring
More informationBS 287 DUAL CHANNEL POWER SUPPLY. User Manual. January 2017 V1.0
BS 287 DUAL CHANNEL POWER SUPPLY User Manual January 2017 V1.0 Table of contents 1.0 SAFETY INSTRUCTIONS... 3 2.0 GENERAL DESCRIPTION PS 289... 4 3.0 MECHANICAL INSTALLATION... 5 4.0 MAINS POWER & SAFETY
More informationStandard icontrol Power Supply Kit
Instruction Sheet P/N 07150A Standard icontrol Power Supply Kit This instruction sheet is a guide for upgrading to the Standard icontrol Power Supply. WARNING: Allow only qualified personnel to perform
More informationMAXIMA+ Series Rotary Level Indicator
MAXIMA+ Series Rotary Level Indicator BinMaster: Division of Garner Industries 7201 N. 98th St., Lincoln, NE 68507 402-434-9102 email: info@binmaster.com www.binmaster.com OPERATING INSTRUCTIONS PLEASE
More informationCI-tronic Soft start motor controller
MAKING MODERN LIVING POSSIBLE CI-tronic Soft start motor controller MCI 3, MCI 15, MCI 25, MCI 30 I-O, MCI 40-3D and MCI 50-3 I-O Technical brochure Contents Page Soft start motor controller, MCI 3, MCI
More informationSAFETY LOCKING DEVICES
L200 Heavy-Duty L200 Safety Locking Device on a very large gate in a logistics operation with forklift traffic The L200 Safety Locking Device designed for highly demanding applications is predestined for
More informationVersatile Safety Interlock Switch with Guard Door Locking
R Conforms to EN1088, EN60947-5-1, EN292, EN60204-1 UL and C-UL listed, BG approved Versatile Safety Interlock Switch with Guard Door Locking High locking force of 450 pounds locks guard door shut until
More informationTXM1.8RB. TX-I/O Blinds module
s 8 178 8178p01 TX-I/O Blinds module TXM1.8RB 8 non-floating relay outputs for... 4 blinds motors with 2 end switches, or 2 blinds motors with 3 end switches, or 2 blinds motors with 2 end switches + 1
More informationNo cable required between transmitter and receiver. Exact Channel Select. Floating Blanking. Choice of operating modes.
MiniSafe File No. LR90200 Description MiniSafe 0.75 inch (19mm) resolution 65 foot (20 meter) range Protected heights from 10 to 55 inches (263 to 1394mm) Compact size 1.4 x 2 inches (35 x 50mm) Simple
More informationInstallation & Operation Guide
Installation & Operation Guide Direct Digital VAV Controllers KMD-7001/7051 - VAV Terminal Units KMD-7002/7052 - Dual Duct VAV Units KMD-7003/7053 - Fan Induction Units 907-019-01C 1 Introduction This
More informationSlimline LED Floodlight
Slimline LED Floodlight Model: LEDPRO10WH (White) Model: LEDPRO10B (Black) Model: LEDPRO30WH (White) Model: LEDPRO30B (Black) Model: LEDPRO20WH (White) Model: LEDPRO20B (Black) Model: LEDPRO50WH (White)
More informationASI QUINT /2.4 EFD
Extract from the online catalog ASI QUINT 100-240/2.4 EFD Order No.: 2736686 Power supply unit für AS interface, 2.4 A, integrated ground fault detector, IP20 degree of protection Commercial data EAN 4017918959678
More informationQUINT-PS/ 1AC/24DC/20/CO
Extract from the online catalog QUINT-PS/ 1AC/24DC/20/CO Order No.: 2320898 DIN rail power supply unit 24 V DC/20 A/CO, dip-coated circuit board, primary-switched, 1-phase. For the first time, SFB (selective
More informationQUINT-PS/1AC/24DC/10. Extract from the online catalog. Order No.:
Extract from the online catalog QUINT-PS/1AC/24DC/10 Order No.: 2866763 DIN rail power supply unit 24 V DC/10 A, primary-switched mode, 1- phase. The SFB technology (Selective Fusebreaking Technology)
More informationMAXIMA + Series ROTARY LEVEL CONTROL
Price $5.00 MAXIMA + Series ROTARY LEVEL CONTROL OPERATING INSTRUCTIONS PLEASE READ CAREFULLY Division of Garner Industries 7201 North 98th Street Lincoln, NE 68507-9741 (402) 434-9102 925-0268 Rev. A
More informationDEEP SEA ELECTRONICS PLC
COMPLEX SOLUTIONS MADE SIMPLE DEEP SEA ELECTRONICS PLC DSE705 ATS CONTROL MODULE OPERATING MANUAL Deep Sea Electronics Plc Highfield House Hunmanby North Yorkshire YO14 0PH ENGLAND Sales Tel: +44 (0) 1723
More informationLOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E
LOGIC CONTROLLER INSTALLATION MANUAL NTR 756 B /E Table of contents 1. INTRODUCTION...1 2. HARDWARE DESCRIPTION...2 3. INSTALLATION...6 4. CONNECTION...8 5. USER SAFETY AND PROTECTION OF THE EQUIPMENT...11
More informationPTC/PT100 board 2.0 Option
PTC/PT100 board 2.0 Option Instruction Manual - English PTC/PT100 board 2.0 Option Instruction Manual - English Document number: 01-3873-01 Edition: r1 Date of release: 2006-10-30 Copyright Emotron AB
More informationDatasheet - SLB 200-C04-1R
14.02.2013-17:06:30h Datasheet - SLB 200-C04-1R Safety light barriers / Safety monitoring modules to monitor safety light barriers / SLB 200-C Up to 2 light barrier pairs SLB 200 can be connected 1 safety
More informationGEMÜ 723 Motorized ball valve
Motorized ball valve Features High flow rates Low weight Choice of various body materials and connection types Available as shut off or control valve / and /-way versions available The / and/or /-way ball
More information3RV1 Circuit-Breakers
SIRIUS 3R Description Mountable accessories 3RV1 Circuit- Breakers Circuit-breaker S00 with mountable accessories 3 2 1 5.1 NSK-7715a 4 Circuit-breaker S0 with mountable accessories 1 7 3 5.2 2 6 NSK-7716a
More informationSMARTSCAN INFORMATION
SMARTSCAN INFORMATION RY4 SERIES SAFETY RELAYS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.com, www.smartscan.co.uk
More informationQUINT-PS/ 1AC/24DC/ 5
Extract from the online catalog QUINT-PS/ 1AC/24DC/ 5 Order No.: 2866750 DIN rail power supply unit 24 V DC/5 A, primary switched-mode, 1- phase. The SFB technology (Selective Fuse Breaking Technology)
More informationQUINT-PS AC/24DC/10
Extract from the online catalog QUINT-PS-100-240AC/24DC/10 Order No.: 2938604 DIN rail power supply unit 24 V DC/10 A, primary switched-mode, 1- phase Commercial data EAN 4017918890537 Pack 1 Pcs. Customs
More informationSwitching Power Supply
Switching Power Supply Highly Reliable and Full-functioned 1-year Life Expectancy, 12, 1, or 24 V output voltages, and 30, 60, 0, or 10 W power ratings. 8 to 132 VAC or 170 to 264 VAC switchable input
More informationDatasheet - ZS Z
Datasheet - ZS 236-11Z Position switch / 236 thermoplastic enclosure - DIN EN 50047 with Actuator / 236 Plunger S thermoplastic enclosure Good resistance to oil and petroleum spirit Wide range of alternative
More informationSafe monitoring relays
monitor for safe standstill monitoring Approvals Block diagram Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous LED indicator
More informationRelative and differential pressure transmitter type 652
Relative and differential pressure transmitter type 652 Pressure range 0... 50 1000 mbar Type 652 pressure transmitters are ideally suited to the continuous monitoring of liquid or level, (especially in
More informationMSR 2400W. Multi purpose Power System for Telecom and Industrial Applications. Nominal Output Voltage. Voltage Setting Range
MSR 2400W Multi purpose Power System for Telecom and Industrial Applications 2400 W modular system All voltages available 0 144VDC per module U and I adjustable from 0 to max value Hot-swap plug-in modules
More informationPressure switch KP. Data sheet
Data sheet Pressure switch KP The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems.
More informationAV24-MFT AV24-MFT2 AV24-MFT2-C105. Power consumption In operation For wire sizing N 1700 N Control Control signal Y Operating range
echnical data sheet AV4-MF()(-C105) Multi-functional linear actuators for -way and 3-way globe valves Actuating force 500 N Nominal voltage AC/DC 4 V Control: modulating DC 0 10 V Position feedback DC
More informationProducts no longer available
echnical data sheet NVF4-MF(-E)-R Modulating linear actuator with emergency function for -way and 3-way globe valves Actuating force 800 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position
More informationUser manual Technical parameters
User manual Technical parameters thyro System english Thyristor for reactive current compensation 2 KBR GmbH Subject to technical changes Contents Intended use... 4 Safety Notes... 6 Application range...
More informationEXPANSION PERIPHERAL CVM-R10 C. (Code ) INSTRUCTION MANUAL ( M / 00 A ) (c) CIRCUTOR S.A.
EXPANSION PERIPHERAL CVM-R10 C (Code 7 70 217 ) INSTRUCTION MANUAL ( M 981 170 / 00 A ) (c) CIRCUTOR S.A. ------ CVM-R10 C Peripheral --------------- Pag. 1 CVM-R10C EXPANSION PERIPHERAL 1.- DESCRIPTION
More informationegate Product Catalog Electronic activegate Control Stabilize your Process
Product Catalog Electronic activegate Control Stabilize your Process CAT-16-0013_EN-Rev06 EN 05/2017 Electric Valve Gate Product Description Hot Runner System Patented electronically actuated Valve Gate
More informationPositive-guided relay outputs: 3 safety contacts (N/O), instantaneous. 1 auxiliary contact (N/C), instantaneous
Safety relay for monitoring E-STOP pushbuttons. Approvals Unit features Positive-guided relay outputs: 3 safety contacts (N/O), instantaneous 1 auxiliary contact (N/C), instantaneous Safe separation of
More informationOT EASY 60 II. LED control unit Operating instructions
II LED control unit Operating instructions Contents Safety... 4 General instructions 4 Safety instructions 4 Intended use 4 Description... 5 Function and application 5 Function 5 Important definitions
More informationPlexo IP 55/IP 66. Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE. For reference only.
Plexo IP 55/IP 66 Makes your day, rain or shine PLEXO / WEATHERPROOF PRODUCT GUIDE www.legrand.com.sg Plexo IP 55 Ingenious features for easy installation >> Time saving guaranteed: no cut-out Uncut pierceable
More informationTSXPAY262 Preventa safety module - 24 V DC - standard format - < 5 W
Characteristics Preventa safety module - 24 V DC - standard format - < 5 W Main Range of product Product or component type Complementary [Us] rated supply voltage Supply voltage limits Activation threshold
More informationMRT1 Test Unit. Manual MRT1 (Revision A)
MRT1 Test Unit Manual MRT1 (Revision A) Woodward Manual MRT1 GB Woodward Governor Company reserves the right to update any portion of this publication at any time. Information provided by Woodward Governor
More informationThis document describes the features and functional specifications of the ECONO3 air conditioner controller.
TITLE : FUNCTIONAL SPECIFICATION FOR ECONO3 COOL REV : 01 DATE : MARCH 13, 2001. 1. INTRODUCTION 1.1 Scope of Document This document describes the features and functional specifications of the ECONO3 air
More informationPressure switch KP. Data sheet
Data sheet Pressure switch KP The KP pressure switches can be used as safety switches against too low a suction pressure and / or too high a discharge pressure in refrigeration and air conditioning systems.
More informationVEO. V2PF480Y/277VSY01 Art.Nr.: V2PF480Y/277VSY01P Art.Nr.: TECHNICAL DATA
Monitoring of phase sequence and phase loss Monitoring of asymmetry Supply voltage 208-480 V AC Supply circuit = measuring circuit 1 change-over contact Width 22,5 mm Control elements Asymmetry Status
More informationINSTALLATION & OPERATING MANUAL
INSTALLATION & OPERATING MANUAL IC 90 CHECK CONTENTS Package should contain.. Meter. Fixing Brackets (). Installation and Instruction Manual. The IC 90 meter is the latest kwh meter in the 900 series from
More informationASM1, ASM1E, ASM2E. AS-i Safety Monitor. Subject to change without prior notice. Technische Änderungen vorbehalten /02
ASM1, ASM1E, ASM2E AS-i Safety Monitor 50101229-2009/02 Technische Änderungen vorbehalten Subject to change without prior notice Information on the use of the connecting and operating instructions These
More informationPlexo IP 55/IP 66 Makes your day, rain or shine
Plexo IP 55/IP 66 Makes your day, rain or shine PLEXO / WEATHERPROOF WIRING DEVICES www.legrand.com.sg Plexo IP 55 Ingenious features for easy installation >> Time saving guaranteed: no cut-out Uncut pierceable
More informationEasy Analog RNB130. Technical Information. Primary switched-mode power supply
Technical Information Easy Analog RNB130 Primary switched-mode power supply Your benefits Small housing, 35 mm (1.38") width High availability Wide range input - can be used world-wide Power reserve (Power
More informationUniversal Motor Controller UMC22-FBP. Excellent motor protection and control ATEX ABB
Universal Motor Controller UMC-FBP Excellent motor protection and control ATEX ABB FieldBusPlug: the concept ABB s communicative product family comprises a wide range of switching, controlling and automation
More informationVC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide
Beyond Comfort VC3000 Series Line Voltage Switching Relay Pack Controllers Installation Guide August 10 th, 2010 (For Commercial and Lodging HVAC Fan Coil Applications) 028-0296-R1-LIT-VC3000-E01 Index
More informationPART NUMBER STRUCTURE. P-DUKE Technology Co., Ltd Page 1
Medical Automation Datacom IPC Industry Measurement Telecom Automobile Boat Charger PV Railway PART NUMBER STRUCTURE M A H 450 U S 12 - F2 Application Package Dimension Output Input Output Output Protection
More informationE-STOP relays, safety gate monitors
Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous Connection options for: E-STOP pushbutton Reset button LED indicator for: Switch status channel 1/2 Supply voltage See
More information16ADA series Max. output power 16W
Switch mode power supplies 16ADA series Max. output power 16W This product is intended for general use to feed electric and electronic devices in covered rooms, in environments without risk of explosion.
More informationInBin-P Pressure switches from 5 Pa Pa
InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact
More informationS8VE (60/90/120/180/240-W Models)
Switch Mode Power Supply S8VE (60/90/120/180/240-W Models) CSM_S8VE_DS_E_1_1 60/90/120/180/240-W Models Improved Versions of Standard-type Power Supplies without Indication Monitor. Safety standards: UL508/60950-1,
More informationUniversal Power Supplies
, Features Universal input: 90 264 VAC or 120 30 VDC Active power factor correction (>0.95) High efficiency up to 93% Load share function for up to 3 units in parallel Adjustable output voltage EMI/EMC
More informationBlueWave ~ Intelligent Energy Control. Installation and User Manual for BW2/C and BW3/C versions. Quick Guide
BlueWave ~ Intelligent Energy Control Installation and User Manual for BW2/C and BW3/C versions Quick Guide Press button to override or activate Channel 1 Press button to override or activate Channel 2
More informationHZS Internal Controller Expansion
HZS 532-2 Internal Controller Expansion Date of creation: 19.05.2016 Version date: 19.05.2016 Article number: 05-895-532-2E Publisher: SIGMATEK GmbH & Co KG A-5112 Lamprechtshausen Tel.: 06274/4321 Fax:
More informationE-STOP relays, safety gate monitors
Safety relay for monitoring E-STOP pushbuttons and safety gates. Approvals Unit features Positive-guided relay outputs: 2 safety contacts (N/O), instantaneous 2 safety contacts (N/O), delay-on de-energisation
More information24/48/120 VAC Interface Card Instruction Manual
24/48/120 VAC Interface Card Instruction Manual Distributed by Ergonomic Partners Sales@ErgonomicPartners.com www.ergonomicpartners.com Tel: (314) 884-8884 April 2012 Part Number: -R2 Copyright 2012 Magnetek
More informationSAFETY SWITCHES. Phone: Fax: Web: S20 Safety Switch
SAFETY SWITCHES S0 Safety Switch S0 Safety Switch for guarding the sliding door on a pick-and-place machine The S0 is a Safety Switch without guard interlocking, which can always be used when the dangerous
More informationIGLOO IGLOO EASY INSTRUCTION MANUAL
ENGLISH EASY C695 C698 INSTRUCTION MANUAL PRELIMINARY Congratulations on choosing a Clay Paky product! We thank you for your custom. Please note that this product, as all the others in the rich Clay Paky
More informationESB ⅓ Hz 440Hz. Inrush Current Limiter, Inrush Current Protection For capacitive loads, 115Vac/230Vac 16A, 16 ⅓ Hz 440Hz, - 40 C...
ESB101 Made in Germany Inrush Current Limiter, Inrush Current Protection For capacitive loads, 115Vac/ 16A, 16 ⅓ Hz 440Hz, - 40 C...+70 C Short Specification: Peak- / R.M.S. current limiter 90-130Vac /
More informationUser s guide. Torch height controller. Model : THC Controller
User s guide Torch height controller. Model : THC Controller SAFETY WHILE OPERATING THE DEVICE HAS INSIDE ITS CASING AND ON ITS CONNECTORS HIGH VOLTAGE WHICH IS DANGEROUS FOR HUMAN LIFE AND HEALTH. Remember
More informationOperating and Maintenance Instructions
Part No Description Dual EC Fan Controller Issue Date Bug no Comments 1 10 July 2012 1205 Signed CE front sheet & instructions clarified 2 28 Jan 2013 1205 Instructions clarified, identify Live & SELV
More information