TableofContents. Important Information: Warning: Please read operating manual carefully before operation.

Size: px
Start display at page:

Download "TableofContents. Important Information: Warning: Please read operating manual carefully before operation."

Transcription

1 Important Information: Please read operating manual carefully before operation. Warning: Overpush or overdraw the syringe may result in the fluid sprayed. Use appropriate measures to protect operator and equipment. Be careful during operation. When the fluid sprays out on the drive unit please shut down the power supply immediately and clean the drive unit, then turn on the power supply. If a trouble happens please contact us or our dealer. Don't repair the equipment by yourself. Be careful when inserting or extracting the connection wire between controller and drive unit to prevent the plug from damaging. If the power line or the plug are worn or damaged please pull out the plug. Please shut down the power supply before connecting the external control equipment. TableofContents Introduction Operation Panel Basic Operation Start/Stop Key Fast Forward Key Fast Reverse Key Rotary Coded Switch Channels Switch Key Menu Frame Work Multichannel Running Interface Multichannel Functions Setting Drive Unit Copy Parameters Set Delay Time Controller I.D. Single Channel Running Interface Single Channel Functions Setting Working ion meters Setting Acceptable Drive Units and Syringes Syringe Loading External Control Function Maintenance Warranty Technical Specifications

2 Introduction TS series products are controllers of four channels and multifunction syringe pumps. They need to be connected with drive units to constitute syringe pump systems of strong functions and easytooperate. They are widely used in biological laboratory. There are 3 types: Controller Type TSA TSA TSB DriveUnitType L007A L007A W009B Working Mode Infusiononly Infusion/Withdrawal Infusion/Withdrawal Operation Panel Fast Forward Key Channels Switch Key Fast Reverse Key Start/Stop Key Rotary Coded Switch S S3 S S Controller S Drive Unit S3 Glass Syringe F5 F F Power Switch F F4 F Power Socket F3 F3DriveUnitSocket F4 External Control Input and Communication Interface F5 External Control Output Interface Controller and drive unit are connected through 8 pin S terminal. Be careful when insertion or extraction. Please see page for detail information about External control function. Basic Operation Start/Stop Key Start/Stop Key to start or stop the pump. In multichannel working mode, to pause the running state, the pump will prompt if continue the current working state. Fast Forward Key In multichannel working mode, pressing the Fast Forward Key all the enabling channels infuse at the max. speed. In single channel working mode, pressing the Fast Forward Key this channel infuses at the max. speed. Loose this key the pump stops. Other keys are invalid when pressing this key. Fast Reverse Key In multichannel working mode, pressing the Fast Reverse Key all the enabling channels withdraw at the max. speed. In single channel working mode, pressing the Fast Reverse Key this channel withdraws at the max. speed. Loose this key the pump stops. Other keys are invalid when pressing this key. Fast Forward Key and Fast Reverse Key are invalid when the pump is in running state. Rotary Coded Switch () Turn the Rotary Coded Switch for menu selection or parameter setting. Rotary Coded Switch for confirmation. Put the finger in the center of the switch to press the. Put the finger on the small concave which is on the side of the switch to. Channels Switch Key Switch between different channels. Cancel current operation and return to previous menu.

3 Menu Frame Work Multichannel Running Interface #: #: 3#: 4#: Unit: # # 3# 4# # # 3# 4# Delay time: # 6.0 sec # 0.0 sec 3# 0.0 sec 4# 0.0 sec Controller ID: # nl/sec 0.0 sec Syringe: 00μL #V ol: 360 μl 40 sec 5 Syringe: 500μL 3# Vol: 860 μl 68.3 sec 0 Syringe: 000μL Infusion Withdrawal I/W W/I Continuous Unimetrics Becton Dickinson Hamilton Barrel I.D. Disp Vol Unit μL Infusion Unit 8.5 sec Withdrawal Unit 7.0 sec Copy No.: 0 Pause Time: 0. min Vol: 50.00μL Time: 60sec Act: 50.00μL Yes No Cancel Switch on the pump. First initializing, and then display the running interface. #: #: 3#: 4#: a b #: #: 3#: 4#: a. Enabling symbol: Symbol of enabling or disabling the channels. Means enabling the current channel. means disabling the current channel. The disabling channel is invalid when the pump is in running state or switching the channels. b. Channel number: Channel serial number. c. Start/Stop state: Display the state of current channel. Start displays. Stop displays. Pause displays. d. Direction: Display running direction. Infusion displays. Withdrawal displays. e. Working mode: Display current working mode. Display in infusion, withdrawal, infusion/withdrawal, withdrawal/infusion modes. Display in continuous mode. Multichannel Functions Setting Drive Unit: Means enabling the current channel. Means disabling the current channel. The disabling channel will not work when the pump is working. The setting method is as below: Unit: # # 3# 4# # # 3# 4# Yes or No e d c Unit: # # 3# 4# # # 3# 4# to set the enabling channels Turn the 4# Vol:700 nl 5 sec Syringe: 0μL : Volume Speed Flow Unit: # # 3# 4# # # 3# 4# Turn the to select the channels 3 4

4 Copy Parameters the parameters of one drive unit as copy parameters, all enabling channels will run according to copy parameters. Not setting copy parameters each enabling channel will run according to its own parameters setting. Means copy channel; means noncopy channel. Only one channel can be selected as copy channel, or noncopy channel is acceptable. The setting method is as below: #: #: 3#: 4#: Set Delay Time #: #: 3#: 4#: Unit: Unit: # # 3# 4# # # 3# 4# # # 3# 4# # # 3# 4# Yes the copy channel or No Turn the Unit: # # 3# 4# # # 3# 4# Delay time: # : 6.0 min # : 0.0 sec 3# : 0.0 sec 4# : 0.0 sec 5 Turn the Yes or No Unit: # # 3# 4# # # 3# 4# to set the copy channel Set delay time to start each drive unit in turn. Time units are sec, min and hour. Time numerical value is from 0. to The setting method is as below: if save the change Turn the to set the delay time Delay time: # : 6.0 sec # : 0.0 sec 3# : 0.0 sec Delay time: # : 6.0 sec # : 0.0 sec 3# : 0.0 sec channel Delay time: # : 6.0 min # : 0.0 sec 3# : 0.0 sec 4# : 0.0 sec Turn the to set the time unit Controller I.D. When control computer controls many pumps through RS485 interface, it must identify each controller's I.D.. This controller I.D. should be unique. It's the identification of this controller. The controller address serial number is from to 30. The default is. The setting method is as below: #: #: 3#: 4#: #: #: 3#: 4#: Single Channel Running Interface Unit: # # 3# 4# # # 3# 4# 6 Controller ID: Turn the Yes or No # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Controller ID: Turn the to set the controller I.D. Switch on the pump. First initializing, and then display the multichannel running interface. Press Channels Switch Key to enter single channel running interface. Please see below for detail operation: Press Channels Switch Key Press Channels Switch Key # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Press Channels Switch Key 3# Vol:.860 μl 8.3 sec 0 Syringe: 00μL Press Channels Switch Key 4# Vol:.860 μl 8.3 sec 0 Syringe: 00μL

5 Three Display Modes for Single Channel Running Interface: Volume Display a. b. c. d. Speed Display # Vol:.860 μl 8.3 sec 0 Syringe: 00μL e. f. g. Single Channel Functions Setting 5 functions are set: # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Please see page 6 Display for Speed and Turn the Flow Rate Display #: 6.75mm/min 8.3 sec 0 Syringe: 00μL #: 4.0nL/sec 8.3 sec 0 Syringe: 00μL a.display mode: Display the current volume, flow rates or speed. Please see page 6 for setting method. b.time: Required time for one time infusing or withdrawal. Counting down when running. c.syringe: Display selected syringe. d.start/stop state: Start displays ; Stop displays ; Pause displays. e.copy number: Display dispensing copy number. Counting down when running (no display in continuous mode). f. Working mode: Display current working mode. Display in infusion, withdrawal, infusion/withdrawal, withdrawal/infusion modes. Display in continuous mode. g.direction: Display running direction. Infusion displays. Withdrawal displays. 7 TSA controller disables. It only has infusion working mode. Working ion # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Please see page 6 Display for Speed and Yes to save the No not to save to return Prompts working mode Yes or No 8 Infusion Withdrawal I/W W/I Turn the to select working mode Continuous Turn the Turn the to select working mode Infusion: The pump infuses during the whole working course Withdrawal: The pump withdraws during the whole working course Infusion/Withdrawal: The pump infuses first and then withdraws during the whole working course Withdrawal/Infusion: The pump withdraws first and then infuses during the whole working course Continuous: The pump infuses first and then withdraws, and then cycles continuously Please see page Dispensing Parameters Setting to set the parameters for above working modes.

6 Standard Syringe # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Please see page 6 Display for Speed and the specification Three syringe manufacturers are listed in the TSA,TSA menu. Please see below table for specifications: Unimetrics Yes to save the No not to save to return Unimetrics Hamilton SGE Spec( μl) I.D. ( mm) Spec( cc) I.D. ( mm) I.D. ( mm) Turn the to highlight Yes or No Size ( μl) I.D. :.3mm Unimetrics Becton Dickinson Hamilton Barrel I.D. the type Three syringe manufacturers are listed in the TSB menu. Please see below table for specifications: Becton Dickinson Hamilton Spec( μl) I.D. ( mm) Spec( ml) Spec( μl) I.D. ( mm) Spec( μl) I.D. ( mm) Setting and the Inner Diameter of the Syringe. Setting the Inner Diameter of the Syringe If the syringe used is not listed in the menu the inner diameter of the syringe needs to be measured and entered (0.0 mm 40 mm). The pump can save 4 inner diameters of the syringes. # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Please see page 6 Display for Speed and # : 8.00mm # : 0.00mm 3# : 0.00mm 4# : 0.00mm Yes # : 8.00mm # : 5.00mm 3# : 0.00mm 4# : 0.00mm Yes to save the No not to save to return No # : 0.00mm # : 0.00mm 3# : 0.00mm 4# : 0.00mm # : 8.00mm # : 0.00mm 3# : 0.00mm 4# : 0.00mm. the Inner Diameter of the Syringe the inner diameter of the syringe after setting the inner diameter. Turn the to highlight the Turn the to set the inner diameter Unimetrics Becton Dickinson Hamilton Barrel I.D. 0 Yes or No Yes or No Unimetrics Becton Dickinson Hamilton Barrel I.D.

7 meters Setting The dispense parameters include dispense volume, infusion time, withdrawal time, copy number and pause time. Dispense volume: It is the volume for one time infusion or withdrawal The volume range is nl to ml There are volume units of nl, 0.0nL, 0.μL, μl and 0.0mL available. # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Please see page 6 Display for Speed and Yes to save the No not to save to return Turn the and highlight the Yes or No Disp Vol Unit μL Infusion Unit 8.5 sec Disp Vol Unit μL Infusion Unit 8.5 sec Turn the and set the unit Disp Vol Unit μL Infusion Unit 8.5 sec Turn the to set the volume When the one time dispensing volume or the total dispensing volume (multiply one time dispensing volume by copy number) are more than the volume of the syringe the running interface will display Vol Overflow (see below). Please change the syringe or adjust the dispensing volume or the copy number. Vol overflow! 8.3 sec 0 Syringe: 00μL Infusion time: It is the time for one time infusion The range of infusion time is from 0. second to hours There are time units of second, minute and hour available # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Please see page 6 Display for Speed and Yes to save the No not to save to return Turn the and highlight the Yes or No When the pump can't infuse volume in time the running interface will display Ispeed Overflow (see below). Pleaseadjustthedispensingtimeorthedispensingvolume. Ispeed Overflow! 8.3 sec 0 Syringe: 00μL Disp Vol Unit μL Infusion Unit 8.5 sec Disp Vol Unit μL Infusion Unit 8.5 sec Turn the and set the unit Disp Vol Unit μL Infusion Unit 8.5 sec Turnthe tosetthetime

8 Withdrawaltime:Itisthetimeforonetimewithdrawal The range of withdrawal time is from 0. second to hours There are time units of second, minute and hour available # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Please see page 6 Display for Speed and Yes to save the No not to save to return Turn the and highlight the Yes or No Wspeed Overflow! 8.3 sec 0 Syringe: 00μL Withdrawal Unit 8.3 sec Copy No.: Withdrawal Unit 8.3 sec Copy No.: Turn the and set the unit Withdrawal Unit 8.3 sec Copy No.: Turnthe tosetthetime When the pump can't withdrawal volume in time the running interface will display Wspeed Overflow (see below). Please adjust the dispensing time or the dispensing volume. Copy Number: It is the total infusion and withdrawal numbers of the whole working course. The range is 999. In Infusion/Withdrawal (I/W) and Withdrawal/Infusion (W/I) modes, one time working course is finishing one time infusion and withdrawal. # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Please see page 6 Display for Speed and # Vol:.860 μl 8.3 sec 0 Syringe: 00μL Yes to save the Yes to save the No not to save to return 3 4 Vol overflow! 8.3 sec 0 Syringe: 00μL Pause Time: 0. min Pause Time: No not to save Withdrawal Unit 60.0 sec to return Copy No.: Turn the and set the copy number When the one time dispensing volume or the total dispensing volume (multiply one time dispensing volume by copy number) are more than the volume of the syringe the running interface will display Vol Overflow (see right). Please change the syringe or adjust the dispensing volume or the copy number. Turn the and highlight the DispensePara Yes or No Yes or No Pause Time: It is the stop time between two dispensing operation. Therangeis min. Please see page 6 Display for Speed and Turn the and highlight the DispensePara Withdrawal Unit 60.0 sec Copy No.: 0. min Turn the and set the pause time

9 When the accuracy of the dispensing volume can not reach 0.5% (in the condition of 30% of max. infusion distance), calibration is needed to adjust the linear speed of the drive unit. 8.3 sec 0 # Vol:.860 μl Syringe: 00μL 8.3 sec 0 Syringe: 00μL Please see page 6 Display for Speed and Turn the and highlight the Yes or No Interface A 0% 50% 80% Vol: Time: 60sec Act: 0.00μL Vol: 0.00μL Time: 60sec Act: 0.00μL Start/Stop Key to start the test # Vol:.860 μl Please see page 6 Display for Speed and Yes to save the No not to save to return : Volume Speed Flow Turn the and highlight the Display Mode the Display Mode Yes or No Yes to save the No not to save to return Turn the to enter the calibration volume Yes or No Vol: 0.00μL Time: 60sec Act: 0.00μL Vol: 0.00μL Time: 60sec Act: 0.00μL Turn the to enter the actual volume There are volume, speed and flow rate display modes available. Volume: Display current one time infusion or withdrawal volume Speed: Display current running speed Flow rates (Flow): Display current flow rates Volume (Vol): The required volume for calibration Enter volume setting interface (see Interface A) and to set the calibration volume. There are 0%, 50% and 80% of the syringe volume available. When selecting the userdefined syringe the default calibration volume is 50% of the syringe volume. Please see page 9 to select suitable syringe. Time: The calibration time for the pump is minute. Actual volume (Act): Start/Stop Key after setting the calibration volume. Enter the actual volume. 5 6

10 Acceptable Drive Units and Syringes TSB/W009B TSA/L007A TSA/L007A Drive Unit Glass Syringe Drive Unit Glass Syringe Controller Controller Reference Flow Rates List Syringe Material Glass Syringe Specification ( μl) Glass Syringe Inner Diameter (mm) Flow Rate (/min) Glass Syringe nL 3.30nL 3.8μL 33.0μL 6.60nL 66.0μL 3.8nL 3.8μL 3.96nL 39.6μL 66.nL 66.μL 3.4nL 34.μL Syringe Material Syringe Specification ( μl) Flow Rate (/min) Syringe Material Syringe Specification ( cc) Flow Rate (/min) Syringe Material Syringe Specification ( ml) Flow Rate (/min) Glass Syringe nL 3.30nL 3.8μL 33.0μL 6.60nL 66.0μL 3.8nL 3.8μL 3.96nL 39.6μL Plastic Syringe 66.nL 66.μL 0.38μL 0.460μL 0.896μL.306μL.6μL.904μL.38mL 4.60mL 8.96mL 3.06mL.6mL 9.04mL Plastic Syringe 3.4nL 34.μL μL 0.330μL 0.66μL.33μL 3.305μL 6.60μL.3mL 3.30mL 6.6mL 3.3mL 33.05mL 66.0mL μl ml 7 8

11 Syringe Loading TSB/W009B TSA/L007A Pressing Knob Plunger Fixing Board. Lift up and rotate the pressing knob Barrel Fixing Board.Rotate the tightening knobs according to the arrowhead directions. Loose the plunger fixing board and the barrel fixing board Loading Pole. 3. Lift up the pressing knob and rotate the press knob according to the arrowhead direction to fix the glass syringe See above drawing to load the glass syringe Pressing Knob.Lift up the pressing knob and rotate the pressing knob according to the arrowhead direction. Load the syringe. Rotate the pressing knob to press the syringe TSA/L007A. Lift up and rotate the pressing knob. Rotate and loose the tightening knobs according to the arrowhead directions Pressing Knob Loading Pole. See above drawing to load the glass syringe. Lift up the press knob and rotate the press knob according to the arrowhead direction to press the glass syringe Tightening Knob 3.Tighten the tightening knobs according to the arrowhead directions to fix the syringe 3. Rotate the tightening knobs according to the arrowhead directions to fix the glass syringe Tightening Knob 9 0

12 External Control Function External Control Output Interface Start/Stop State Output Direction State Output Maintenance Keep the surface of the pump clean and dry. Prevent the liquids from entering the inner of the drive units. The surface of drive units are not organic solvent and aggressive liquids resistant. Please pay attention when using. Note If a trouble happens, please contact us or our dealers. Warranty Channel 3 4 Channel Channel 3 Channel Stop State: OC gate is open ( )(5 6)(9 0)(3 4) Running State: OC gate is close are 4 suits OC gates Infusion: OC gate is open Withdrawal:OCgateisclose (3 4)(7 8)( )(5 6) are 4 suits OC gates External Control Input and Communication Interface Port Definition: # +5V # COM 3# COM for external control start/stop 4# External control start/stop: change to high level, start and stop states switch 5# NC 6# COM for Rs485 7# RS485 B 8# RS485 A 3# are RS485 communication bus ports. Can connect to the control computer (computer, PLC, SCM). The warranty period for this product is one year. If repair or adjustment is necessary within the warranty period, the problem will be corrected at no charge if it is not due to misuse or abuse on your part, as determined by the manufacturer. Repair costs outside the warranty period, or those resulting from product misuse or abuse,maybeinvoicedtoyou. TSA/L007A TSA/L007A TSB/W009B Technical Specifications System Functions Parameters Setting: The parameters of each channel can be different Parameters Saving: The parameters of each channel can be saved Running Control: Each drive unit can be controlled separately; Or four drive units can be controlled to run simultaneously or run at different time Copy Channel: All drive units can be run according to the parameters of one drive unit of them Delaying Startup: Delaying startup time of each channel can be controlled separately Memory Function: resume operation or remain stopped when power returns after an interruption Block Protection: When one drive unit stops accidently, the system will warm and stop External Control: Each channel has two ways OC gate output to indicate the start/stop and running direction of this channel Communication: Realize computer control through RS485 communication interface Main Functions for Each Channel ion: The syringe can be selected in the manufacturer table which includes manufacturer and size Userdefined Syringe: 4 inner diameter of userdefined syringe barrel canbeinputandsaved Working Mode Setting: TSA has only infusion working mode. TS A/TSB has 5 working modes available: infusion, withdrawal, infusion/withdrawal, withdrawal/infusion, continuous Parameters Setting: Set dispensing volume, infusion time, withdrawal time, pause time and copy number Display ion: Different parameters (volume, flow rate, linear speed) can be selected in the main display interface FastForward&FastReverse:Infusionorwithdrawalatthemax.speed : Acquire accurate volume through calibration

13 TSA/L007A, TSA/L007A Specifications Max. Infusion Distance: 70 mm AcceptableGlassSyringe:5μL000μL Linear Speed: 7.94 μm/min 79.4 mm/min Adjusting Resolution: 7.94 μm/min Distance Resolution: 0.65 μm Linear Force: > 0 N Setting Mode: Membrane Keypad and rotary coded switch Accuracy: ± 0.5% error in the condition of 30% of max. infusion distance Display: 8x64 graphic LCD External Control: Input control: start/stop Output control: start/stop, direction (OC gate) Communication Interface: RS485 Power:AC00V40VorDCV/3.A Power Consumption: 4W OperatingCondition:Temperature040 Relative humidity 80 % ControllerDimensions(L W H): Controller Weight: 0.9 Kg DriveUnitDimensions(L W H): (mm) DriveUnitWeight:0.6Kg IP Rating: IP TSB/W009B Specifications Max. Infusion Distance: 90 mm AcceptableSyringe:5μL60mL Linear Speed: 7.9 μm/min 79.4 mm/min Adjusting Resolution: 7.94 μm/min Distance Resolution: 0.65 μm Linear Force: > 90 N Setting Mode: Membrane Keypad and rotary coded switch Accuracy: ± 0.5% error in the condition Of 30% of max. Infusion distance Display: 8x64 graphic LCD External Control: Input control: start/stop Output control: start/stop, direction (OC gate) Communication Interface: RS485 Power:AC00V 40VorDCV/3.A Power Consumption: 34W OperatingCondition:Temperature040 Relative humidity 80 % ControllerDimensions(L W H): Controller Weight: 0.9 Kg DriveUnitDimensions(L W H): (mm) DriveUnitWeight:3Kg IP Rating: IP4 3 4

14 BaodingLongerPrecisionPumpCo.,Ltd ADD: Building A,Chuangye Center Baoding National High Tech Industrial Development Zone Baoding, Hebei, China 0705 TEL: FAX: E mail: longer@longerpump.com Longer Syringe Pump Operating Manual SYRINGE PUMP OPERATING MANUAL TSA/L007A TSA/L007A TSB/W009B Baoding Longer Precision Pump Co., Ltd.

kd Scientific Model 200 Series

kd Scientific Model 200 Series kd Scientific Model 200 Series Contents Introduction 1 Specifications 2 Features 3 Operating Instructions 13 Power switch 6 Syringe loading 6 Withdrawal operation 6 Menu features 8 Keypad functions 8 Fast

More information

Intelligent Flow Rate Peristaltic Pump- Lab V Series. Model No.: Lab V1, Lab V3, Lab V6. Acceptable Pump Head: YZ1515x, YZ2515x, SN Series, MC Series

Intelligent Flow Rate Peristaltic Pump- Lab V Series. Model No.: Lab V1, Lab V3, Lab V6. Acceptable Pump Head: YZ1515x, YZ2515x, SN Series, MC Series Intelligent Flow Rate Peristaltic Pump- Lab V Series Model No.: Lab V1, Lab V3, Lab V6 Acceptable Pump Head: YZ1515x, YZ2515x, SN Series, MC Series New Features 1. Portable handheld design, feel comfortable

More information

The Stoelting Quintessential Injector (QSI)

The Stoelting Quintessential Injector (QSI) Operation Manual The Stoelting Quintessential Injector (QSI) Direct infusion and/or withdrawal of small (i.e. pico-, nano-, micro-liter) volumes Catalog Number 53311 Stoelting Co. Revised May 2007 Stoelting

More information

Pump 33 DDS Dual Drive System

Pump 33 DDS Dual Drive System Pump 33 DDS Dual Drive System User s Manual Pump 33 DDS 70-3333 Table of Contents SUBJECT PAGE # Warranty & Repair Information 2 Safety Information 3 Product Overview - Theory of Operation 4 Features 4

More information

CMA 4004 Syringe Pump

CMA 4004 Syringe Pump CMA 4004 Syringe Pump USER S MANUAL CMA-Harvard Apparatus 4004 Syringe Pump Publication 5800-001 Rev 1.0 www.microdialysis.com Table of Contents SUBJECT Table of Contents PAGE NO. General Information...6

More information

New Era Pump Systems Inc.

New Era Pump Systems Inc. New Era Pump Systems Inc. WWW.SYRINGEPUMP.COM Model: NE-300 Just Infusion NE-1000 Family of Programmable Syringe Pumps Infusion Rate 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 Time WHAT S YOUR APPLICATION?

More information

New Era Pump Systems Inc.

New Era Pump Systems Inc. New Era Pump Systems Inc. WWW.SYRINGEPUMP.COM Multi-Phaser Model: NE-1000 NE-1000 Family of Programmable Syringe Pumps Infusion Rate 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 Time WHAT S YOUR APPLICATION?

More information

SyringePump.com. Model: NE-4000 Two Channel Syringe Pump Multi-Phaser NE-1000 Series of Programmable Syringe Pumps Firmware Version: V3.

SyringePump.com. Model: NE-4000 Two Channel Syringe Pump Multi-Phaser NE-1000 Series of Programmable Syringe Pumps Firmware Version: V3. SyringePump.com Model: NE-4000 Two Channel Syringe Pump Multi-Phaser NE-1000 Series of Programmable Syringe Pumps Firmware Version: V3.919 Infusion Rate 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90

More information

GOLANDER PUMP. Operation Manual. For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S.

GOLANDER PUMP. Operation Manual. For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S. GOLANDER PUMP Operation Manual For Microflow Variable-Speed Peristaltic Pump BT50S/BT102S info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents Safety Cautions... 1 1 Description... 1 2

More information

SYRINGE PUMPS SO ADVANCED, THEY RE SIMPLE!

SYRINGE PUMPS SO ADVANCED, THEY RE SIMPLE! SYRINGE PUMPS SO ADVANCED, THEY RE SIMPLE! MICROPROCESSOR CONTROLLED EXTREMELY LOW FREE FLOW PULSE RATES EASY SYRINGE LOADING FAST FORWARD/FAST REVERSE CONTINUOUSLY VARIABLE FLOW RATE ACROSS THE FLOW RATE

More information

SyringeTWO Programmable Syringe Pump User s Manual

SyringeTWO Programmable Syringe Pump User s Manual SyringeTWO Programmable Syringe Pump User s Manual QUICKSTART Enjoy your pump sooner using this simple guide PARTS INCLUDED In this box you will find: 1 SETUP PUMPING PARAMETERS To Change Numbers: Use

More information

T100&JY15-12 Series Variable Speed Peristaltic Pump Operating Manual

T100&JY15-12 Series Variable Speed Peristaltic Pump Operating Manual T100&JY15-12 Series Variable Speed Peristaltic Pump Operating Manual 2013-6 Contents 1 General Information... 1 1.1 Precaution... 1 1.2 Warranty and Service... 1 1.2.1 Warranty Service... 1 1.2.2 Maintenance

More information

SyringePump.com. Model: NE-1000 Multi-Phaser NE-1000 Series of Programmable Syringe Pumps Firmware Version: V Time

SyringePump.com. Model: NE-1000 Multi-Phaser NE-1000 Series of Programmable Syringe Pumps Firmware Version: V Time 1 SyringePump.com Model: NE-1000 Multi-Phaser NE-1000 Series of Programmable Syringe Pumps Firmware Version: V3.923 Infusion Rate 60 50 40 30 20 10 0 0 10 20 30 40 50 60 70 80 90 Time WHAT S YOUR APPLICATION?

More information

SyringeONE Programmable Syringe Pump User s Manual

SyringeONE Programmable Syringe Pump User s Manual SyringeONE Programmable Syringe Pump User s Manual - QUICKSTART Enjoy your pump sooner using this simple guide PARTS INCLUDED In this box you will find: 1 SETUP PUMPING PARAMETERS To Change Numbers: Use

More information

GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual

GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual GOLANDER PUMP BQ80S Microflow Variable-Speed Peristaltic Pump Operation Manual info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents 1 Safety Cautions... 1 2 Introduction... 1 3 Functions

More information

FT-20 Fire Training Fog Machine User Manual English

FT-20 Fire Training Fog Machine User Manual English FT-20 Fire Training Fog Machine User Manual English 2017 Antari Lighting and Effects Ltd. 1 User Manual - English Safety Information Please read the following safety information carefully before operating

More information

FUSION SERIES USER MANUAL

FUSION SERIES USER MANUAL FUSION SERIES USER MANUAL EU Declaration of Conformity (DoC) 6 Manual Description 7 General Information 7 Safety Information 7 Warranty and Repair Information 9 Limited Warranty 9 Repair Facilities and

More information

Nanoject III. Programmable Nanoliter Injector INSTRUCTION MANUAL

Nanoject III. Programmable Nanoliter Injector INSTRUCTION MANUAL Nanoject III Programmable Nanoliter Injector INSTRUCTION MANUAL 3-000-207 MADE LABORATORY EQUIPMENT E21997 IN USA Rules for Safe Operation For indoor use only. Never operate unit in an explosive atmosphere.

More information

Densitometer DEN-1. Operating instructions. For version V.1GW

Densitometer DEN-1. Operating instructions. For version V.1GW Densitometer For version V.1GW Contents 1 Safety...3 2 General Information...4 3 Getting started...5 4 Operation of...7 5 Maintenance...9 6 Specifications...10 7 Guarantee and service...11 Page 3 1. Safety

More information

Model 11 Plus Syringe Pump User s Manual

Model 11 Plus Syringe Pump User s Manual Model 11 Plus Syringe Pump User s Manual Single Syringe Pump MA1 70-2208 Dual Syringe Pump MA1 70-2209 Single Syringe Pump with Serial Communication MA1 70-2211 Dual Syringe Pump with Serial Communication

More information

ADVANCED SYRINGE PUMP

ADVANCED SYRINGE PUMP instrumentation and software for research ADVANCED SYRINGE PUMP PHM-111-EC USER S MANUAL DOC-032 Rev. 1.8 Copyright 20144 All Rights Reserved Med Associates Inc. P.O. Box 319 St. Albans, Vermont 05478

More information

Date: 00/0 0/00 New Era Pump Systems Catalog

Date: 00/0 0/00 New Era Pump Systems Catalog Date: 00/0 0/00 New Era Pump Systems 2009 Catalog New Era Pump Systems Inc. NE-1000 - $750 The NE-1000 is a full featured, easy-to-use syringe pump for all of your precision fluid dispensing needs. A cost

More information

Cole-Parmer 100 Touch Screen

Cole-Parmer 100 Touch Screen Cole-Parmer 100 Touch Screen USER S MANUAL COLE-PARMER 100 TOUCH SCREEN SERIES w w w. c o l e p a r m e r. c o m Table of Contents Table of Contents SUBJECT PAGE NO. General Information...6 Safety Information...6

More information

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment

Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment FAST SHIPPING AND DELIVERY TENS OF THOUSANDS OF IN-STOCK ITEMS EQUIPMENT DEMOS HUNDREDS OF MANUFACTURERS SUPPORTED

More information

Model Pico Plus Syringe Pump User s Manual

Model Pico Plus Syringe Pump User s Manual Model Pico Plus Syringe Pump User s Manual 70-2213 1 Table of Contents SUBJECT PAGE NO. Table of Contents...1 General Information - Warranty and Repairs...2 General Safety Summary...3-4 Introduction...5

More information

CHEMYX. Intellectual Property. Fusion Series User Manual. Updated: Chemyx Inc Cash Road Stafford, TX USA.

CHEMYX. Intellectual Property. Fusion Series User Manual. Updated: Chemyx Inc Cash Road Stafford, TX USA. CHEMYX Chemyx Inc. 10905 Cash Road Stafford, TX 77477 USA www.chemyx.com Updated: 2016-11-08 Intellectual Property All Intellectual Properties, as defined below, owned by or which is otherwise the property

More information

Model 410 Series Syringe Pumps User s Manual

Model 410 Series Syringe Pumps User s Manual Model 410 Series Syringe Pumps User s Manual Publication 5605-001-REV-D WEEE/RoHS Compliance Statement EU Directives WEEE and RoHS To Our Valued Customers: We are committed to being a good corporate citizen.

More information

PHD 4400 Syringe Pump Series User s Manual

PHD 4400 Syringe Pump Series User s Manual PHD 4400 Syringe Pump Series User s Manual PHD 4400 Hpsi Programmable 70-2200 PHD 4400 Hpsi Remote Programmable 70-2201 Publication 5406-001-REV-G Table of Contents SUBJECT PAGE # Warranty & Repair Information

More information

FUSION 4000 & 6000 USER MANUAL

FUSION 4000 & 6000 USER MANUAL FUSION 4000 & 6000 USER MANUAL EU Declaration of Conformity (DoC)...6 General Description...7 Warranty and Repair Information...9 Warranty Information...9 Repair Facilities and Parts...10 Dead Pixel Policy...10

More information

FT-20 Fire Training Fog Machine User Manual English

FT-20 Fire Training Fog Machine User Manual English FT-20 Fire Training Fog Machine User Manual English 2018 Antari Lighting and Effects Ltd. 1 User Manual - English Safety Information Please read the following safety information carefully before operating

More information

-bio. Densitometer DEN-1B Operating instructions

-bio. Densitometer DEN-1B Operating instructions -bio Densitometer Contents 1 Safety...4 2 General Information...6 3 Getting started...8 4 Operation of...10 5 Maintenance...12 6 Specifications...13 7 Guarantee and service...14 Version 1.01 - May 2012

More information

PHD ULTRA HPSI/XF Syringe Pump Series User s Guide

PHD ULTRA HPSI/XF Syringe Pump Series User s Guide PHD ULTRA HPSI/XF Syringe Pump Series User s Guide PHD ULTRA HPSI MA1 70-3111 PHD ULTRA HPSI MA1 70-3112 (10 syr feeding station) PHD ULTRA XF MA1 70-3313 PATENTS PENDING Table of Contents 2 Table of Contents

More information

A150 Benchtop Conductivity Meter Instruction Manual

A150 Benchtop Conductivity Meter Instruction Manual A150 Benchtop Conductivity Meter Instruction Manual BANTE INSTRUMENTS CO., LTD A150 Benchtop Conductivity Meter 1 Introduction Thank you for selecting the A150 benchtop conductivity meter. This manual

More information

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD

DDS-12DW Benchtop Conductivity Meter. Instruction Manual BANTE INSTRUMENTS CO., LTD DDS-12DW Benchtop Conductivity Meter Instruction Manual BANTE INSTRUMENTS CO., LTD DDS-12DW Benchtop Conductivity Meter 1 Introduction Thank you for selecting the DDS-12DW benchtop conductivity meter.

More information

DIGITAL GEAR PUMP DRIVE OPERATING MANUAL: Model No.

DIGITAL GEAR PUMP DRIVE OPERATING MANUAL: Model No. OPERATING MANUAL: DIGITAL GEAR PUMP DRIVE Model No. 75211-70 Digital Gear Pump Drive 75211-70 A-1299-1142 Edition 01 Cole-Parmer 1-800-323-4340 ((U.S. and Canada only) 11 (847) 549-7600 (Outside U.S.)

More information

MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page #

MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1. Table Of Contents. Section Description Page # MULTISPENSE 2000 W/TOUCHSCREEN CONTROLLER MODULE Page 3-1 Table Of Contents Section Description Page # 3. Multispense 2000 W/Touchscreen Controller Module... 3-2 3.1 Description... 3-2 3.1.1 Front Panel

More information

Nanomite Syringe Pump User s Manual. Nanomite Syringe Pump MA

Nanomite Syringe Pump User s Manual. Nanomite Syringe Pump MA Nanomite Syringe Pump User s Manual Nanomite Syringe Pump MA1 70-2217 WEEE/RoHS Compliance Statement EU Directives WEEE and RoHS To Our Valued Customers: We are committed to being a good corporate citizen.

More information

Legato Series: The Newest

Legato Series: The Newest The Legato product line is the latest generation of syringe pumps. The Legato series offers unparalleled ease of use through the high resolution color touch screen user interface. The full touch screen

More information

Automated Analytical Syringe User Manual

Automated Analytical Syringe User Manual XR Every One an Expert Automated Analytical Syringe User Manual WARNING Only trained laboratory personnel that have read this manual and the warnings and cautions contained in it should operate the evol.

More information

"Infuses Only!" Your partner for Scientific & Medical Equipments

Infuses Only! Your partner for Scientific & Medical Equipments NE-300 "Just Infusion Syringe Pump Holds small or big syringes up to 60 ml Pump continuously until you stop the pump Infusion rate can be changed while pumping Remembers previous settings on power up Power

More information

NANOLITER2010 Nanoliter Injector with SMARTouch Controller

NANOLITER2010 Nanoliter Injector with SMARTouch Controller WORLD PRECISION INSTRUMENTS Instrumenting scientific ideas QUICK START GUIDE NANOLITER2010 Nanoliter Injector with SMARTouch Controller Serial No. www.wpiinc.com 061217 Copyright 2017 by World Precision

More information

SPM Zero dead volume dilutor DATASHEET

SPM Zero dead volume dilutor DATASHEET Environmental conditions Operating temperature Humidity Max pressure 5-40 C (41-104 F) 20-80%, non-condensing 5 bars (72 psi) Fluidic characteristics Tube port fittings Wetted materials Channel diameter

More information

Torque Meter. Instruction Manual

Torque Meter. Instruction Manual Torque Meter 840062 Instruction Manual CONTENTS I. Introduction... 4 II. Meter Description... 4 III. Operating Instructions 1. Measuring Procedures... 5 2. Automatic Shut Off... 6 3. Battery Replacement...

More information

GOLANDER PUMP Operation Manual For Intelligent Dispensing Peristaltic Pump BT100F-1

GOLANDER PUMP Operation Manual For Intelligent Dispensing Peristaltic Pump BT100F-1 GOLANDER PUMP Operation Manual For Intelligent Dispensing Peristaltic Pump BT100F-1 info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents Safety Cautions... 1 1 Description... 1 2 Functions

More information

GOLANDER PUMP. Operation Manual. For Intelligent Dispensing Peristaltic Pump BT101F, BT301F, BT601F.

GOLANDER PUMP. Operation Manual. For Intelligent Dispensing Peristaltic Pump BT101F, BT301F, BT601F. GOLANDER PUMP Operation Manual For Intelligent Dispensing Peristaltic Pump BT101F, BT301F, BT601F info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents Safety Cautions... 1 1 Description...

More information

ml/h ml/h ml/h ml/h or off or off )or off

ml/h ml/h ml/h ml/h or off or off )or off 3 6 ELECTROSURGICAL UNIT MEDITOM DT-400/300S 09... MEDITOM DT-200/150S 10 ml/h ml/h ml/h ml/h or off )or off or off )or off 22 22 SYRINGE PUMP MEDIFUSION MS-2200 A side range of flow rate setting available

More information

Sonic Ruptor 400. User Manual

Sonic Ruptor 400. User Manual Sonic Ruptor 400 User Manual Data herein has been verified and validated. It is believed adequate for the intended use of the instrument. If the instrument or procedures are used for purposes over and

More information

Mini-Rotator with timer for test tubes PTR-25

Mini-Rotator with timer for test tubes PTR-25 Mini-Rotator with timer for test tubes PTR-25 For version V.1GW Contents 1 Safety...3 2 General Information...5 3 Getting started...6 4 Operation...7 5 Specifications...9 6 Guarantee and service...10 7

More information

NIR Moisture Analyzer KB-30

NIR Moisture Analyzer KB-30 NIR Moisture Analyzer KB-30 Operation Manual Safety Precautions FPL950701 Improper use of the NIR moisture analyzer in violation of the following safety notes may result in death, injury or damage to property

More information

PHD ULTRA Syringe Pump Series User s Guide

PHD ULTRA Syringe Pump Series User s Guide PHD ULTRA Syringe Pump Series User s Guide PHD ULTRA Series MA1 70-3xxx PATENTS PENDING Table of Contents 2 Table of Contents SUBJECT PAGE NO. Quick Guide...6 10 Things You Need To Know To Use The PHD

More information

CAPSULE MIXER. User Manual

CAPSULE MIXER. User Manual CAPSULE MIXER User Manual Disclaimer: 1. First of all, we would like to thank you for purchasing Monitex AM-I Optimum Capsule Mixer. Please carefully read the user manual and operate the apparatus accordingly.

More information

Model 33 Twin Syringe Pump User's Manual

Model 33 Twin Syringe Pump User's Manual Model 33 Twin Syringe Pump User's Manual Syringe Pump Model 33 MA1-55-3333 1 Table of Contents SUBJECT PAGE Table of Contents...1 Warranty and Repair Information...2 Specifications...3 Features...4 Initial

More information

PUMP DRIVE OPERA TING MANUAL: A Edition 01

PUMP DRIVE OPERA TING MANUAL: A Edition 01 OPERA TING MANUAL: PUMP DRIVE 77420-00 Pump Drive, shown with 77600-62 High Performance I/P Pump Head. 77420-00 A-1288-0990 Edition 01 1-800-637-3739 (U.S. and Canada only) 11 (847) 381-7050 (Outside U.S.)

More information

Cole-Parmer Modular Touch Screen Dispensing Pump

Cole-Parmer Modular Touch Screen Dispensing Pump Cole-Parmer Modular Touch Screen Dispensing Pump USER S MANUAL COLE-PARMER MODULAR TOUCH SCREEN DISPENSING PUMP SERIES www.coleparmer.com Publication 5607-018-REV-B Table of Contents Table of Contents

More information

Z-380 Fazer Machine User Manual English

Z-380 Fazer Machine User Manual English Z-380 Fazer Machine User Manual English 2015 Antari Lighting and Effects Ltd. User Manual Safety Information Please read the following safety information carefully before operating the machine. Information

More information

Zenith DS9000 Dispensing System

Zenith DS9000 Dispensing System Page Date: 04/2009 Zenith DS9000 Dispensing System Installation & Operation Manual Page 2 Table of Content Introduction... 3 Control Specification... 4 Wiring Diagram... 5 Wiring Instructions... 6 Field

More information

RD-SDM02 Contact Angle Measurement Instrument. Operation Manual

RD-SDM02 Contact Angle Measurement Instrument. Operation Manual RD-SDM02 Contact Angle Measurement Instrument Operation Manual The components of the RD-SDM02 system are not resistant against acids, bases or aggressive organic solvents. RD Support does not provide for

More information

Industrial Peristaltic Pump G100-1J Operating Manual

Industrial Peristaltic Pump G100-1J Operating Manual Industrial Peristaltic Pump G100-1J Operating Manual 1 Content 1 General Information... 4 1.1 Precaution...4 1.2 Warranty and Service... 4 1.2.1 Warranty Service... 4 1.2.2 Maintenance Service... 5 1.2.3

More information

3700 SERIES USER MANUAL

3700 SERIES USER MANUAL SAFETY GUIDE This manual contains the precautions necessary to ensure your personal safety as well as for protection for the products and the connected equipment. These precautions are highlighted with

More information

Torque Meter. Instruction Manual

Torque Meter. Instruction Manual Torque Meter 840062 Instruction Manual Torque Meter - 840062 Copyright 2013 by Sper Scientific ALL RIGHTS RESERVED Printed in the USA The contents of this manual may not be reproduced or transmitted in

More information

Microplate shaker PMS-1000i

Microplate shaker PMS-1000i Microplate shaker PMS-1000i For version V.2GW Page 2 Contents 1 Safety...4 2 General Information...5 3 Getting Started...6 4 Operation of PMS-1000i...7 5 Specifications...9 6 Guarantee and Service...10

More information

MyGenie TM 32 Thermal Block

MyGenie TM 32 Thermal Block User s Guide MyGenie TM 32 Thermal Block A-2030-4 MyGenie TM 32 Thermal Block User s Guide Version No.: 1.1 (2013-05) Please read all the information in booklet before using the instrument Bioneer 8-11,

More information

MG268-F2 USER's MANUAL

MG268-F2 USER's MANUAL MG268-F2 USER's MANUAL Please read this manual seriously before using! Made in China KSJ Photoelectrical Instruments Co., Ltd. Add.: Middle of Binnan Street, Dongbin Industrial Zone, Donghai Bincheng,

More information

Milliliter OEM Pump Module Users Manual

Milliliter OEM Pump Module Users Manual Milliliter OEM Pump Module Users Manual Model #78-2910 Publication # 5417-003 Rev. D WEEE/RoHS Compliance Statement EU Directives WEEE and RoHS To Our Valued Customers: We are committed to being a good

More information

GOLANDER PUMP. Operation Manual. For Intelligent Flow Peristaltic Pump BT100L, BT300L, BT600L.

GOLANDER PUMP. Operation Manual. For Intelligent Flow Peristaltic Pump BT100L, BT300L, BT600L. GOLANDER PUMP Operation Manual For Intelligent Flow Peristaltic Pump BT100L, BT300L, BT600L info@golanderpump.com http://golanderpump.com 1-678-587-8806 Contents Safety Cautions... 1 1 Description... 1

More information

1065AR1_M3_MAN_Argos_OmegaZenPipetteController_Manual.indd 2

1065AR1_M3_MAN_Argos_OmegaZenPipetteController_Manual.indd 2 Pipette Controller Operator's Manual En ligne; Manuel de l opérateur Online; Bedienungshandbuch En línea; Manual del operador In linea; Manuale d uso www.argos-tech.com RoHS 1065AR1_M3_MAN_Argos_OmegaZenPipetteController_Manual.indd

More information

OZONE SWITCH Model OS-6. OS-6 Features

OZONE SWITCH Model OS-6. OS-6 Features USER MANUAL OZONE SWITCH Model OS-6 OS-6 Features The OS-6 is an industrial grade ozone controller and monitor. The OS-6 design is optimized for accuracy and ease of installation, setup and operation.

More information

Z-350 FAZER USER MANUAL

Z-350 FAZER USER MANUAL www.clubsoundrent.nl Z-350 FAZER USER MANUAL English Français Deutsch 2013 Antari Lighting and Effects Ltd. 1 User Manual Safety Information Please read the following safety information carefully before

More information

DEN-1 Densitometer Suspension turbidity detector

DEN-1 Densitometer Suspension turbidity detector Medical Biological Research & Technologies DEN-1 Densitometer Suspension turbidity detector Operating Manual Certificate for version V.1AW Contents 1. Safety Precautions 2. General Information 3. Getting

More information

V1.0. Showven Technologies Co.,Ltd.

V1.0. Showven Technologies Co.,Ltd. V1.0 Showven Technologies Co.,Ltd. Foreword X-S3000 PRO FOG MACHINE USER MANUAL Thanks for choosing SHOWVEN PRO FOG MACHINE. Please read following manual carefully and completely before operating this

More information

HDT-400L HARDNESS TESTER. Instruction Manual

HDT-400L HARDNESS TESTER. Instruction Manual HDT-400L HARDNESS TESTER Instruction Manual Revision 052615-1 LOGAN INSTRUMENTS CORP. 19 C School House Rd., Somerset, NJ 08873 Tel: 732-302-9888 Fax: 732-302-9898 E-Mail: info@loganinstruments.com www.loganinstruments.com

More information

ChEmyx. Nexus Series User Manual. Chemyx Inc Cash Road Stafford, TX USA.

ChEmyx. Nexus Series User Manual. Chemyx Inc Cash Road Stafford, TX USA. ChEmyx Nexus Series User Manual Chemyx Inc. 10905 Cash Road Stafford, TX 77477 USA www.chemyx.com Intellectual Property All Intellectual Properties, as defined below, owned by or which is otherwise the

More information

OPERATING MANUAL: L/S & I/P DIGITAL PUMP DRIVES WITH ETHERNET/IP Model Nos. MASTERFLEX L/S 07551-40 07551-40 07575-50 07575-60 77420-30 77420-40 A-1299-1166 Edition 03 (US & Canada only) Toll Free 1-800-MASTERFLEX

More information

Installation and User Manual. version 1.00 MODWF 2014/53/UE EN : /30/UE EN55022:2010 EN :2005 EN :2007

Installation and User Manual. version 1.00 MODWF 2014/53/UE EN : /30/UE EN55022:2010 EN :2005 EN :2007 Installation and User Manual version 1.00 MODWF 2014/53/UE EN300 328:2016 2014/30/UE EN55022:2010 EN61000-6-2:2005 EN61000-6-4:2007 SYSTEM IDENTIFICATION Load Cell Systems reserves the right to change

More information

Mobile: Fax:

Mobile: Fax: 1.0 DESIGN OF THE DEVICE Hand wheel Name of the calibration curve Measuring chamber Water content Power button LED (green / orange) Batteries slot (flipside) 14.0 WARRANTY Electromatic Equipment Co., Inc.

More information

Super Box. Quick start manual Trouble shooting guide

Super Box. Quick start manual Trouble shooting guide Super Box Quick start manual Trouble shooting guide Super Box Quick start manual 1. How to use the USB memory stick Make sure to either use the provided USB stick or to reformat the USB stick you plan

More information

Installation manual plugs and connectors with screw connection (16/32 A)

Installation manual plugs and connectors with screw connection (16/32 A) EN Installation manual plugs and connectors with screw connection (16/32 60003213 Issue 04.2016 2016-04-01 Table of contents 1 About this manual 3 1.1 Structure of the warnings 3 1.2 Symbols used 4 1.3

More information

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements

USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements USER MANUAL AD331 AD332 Waterproof Portable Meters for EC and TDS Measurements www.adwainstruments.com Dear Customer, Thank you for choosing an Adwa product. Please read carefully this manual before starting

More information

DIGITAL PUMP DRIVES OPERATING MANUAL: Model Nos.

DIGITAL PUMP DRIVES OPERATING MANUAL: Model Nos. OPERATING MANUAL: DIGITAL PUMP DRIVES Model Nos. 77922-18 77922-38 A-1299-7349 Edition 01 Argos Technologies (US only) Toll Free 1-800-866-8675 (Outside US & Canada) 1-800-622-0456 E-mail: info@argos-tech.com

More information

F4 Dosing Pump User Manual (V1.0)

F4 Dosing Pump User Manual (V1.0) F4 Dosing Pump User Manual (V1.0) Kamoer Fluid Tech (Shanghai) Co.,Ltd. www.kamoer.com Contents WARRANTY... 2 NOTICE... 3 1. INTRODUCTION... 4 1.1 ABOUT... 4 1.2 UNPACKING... 5 1.3 STRUCTURE DIAGRAM...

More information

Operating Instructions ProMinent Vario/gamma/Sigma/beta Simulator

Operating Instructions ProMinent Vario/gamma/Sigma/beta Simulator Operating Instructions Vario/gamma/Sigma/beta Simulator Contents Page Unpacking... 2 Description of Controls & Operation... 2 Page Maintenance... 4 Repair Service... 4 Read the operating instructions before

More information

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M

Operation Manual. Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M Operation Manual Hand-held Conductivity/Salinity/TDS/ Temperature Meter 3010M CONTENTS GENERAL INTRODUCTION...2 INITIAL INSPECTION......2 WATER PROOF.......2 INSTALLING THE BATTERIES.....3 DISPLAY & KEYS

More information

LabVIEW Driver. User guide Version

LabVIEW Driver. User guide Version LabVIEW Driver User guide Version 1.0.0 2016 Table of Contents Version History...3 Copyright...4 Software License...5 Operational Safety...6 Warranty and Support...7 Introduction...8 Requirements...9 How

More information

Chemyx. NanoJet Series User Manual. Intellectual Property All Intellectual Properties, as defined below, owned by or

Chemyx. NanoJet Series User Manual. Intellectual Property All Intellectual Properties, as defined below, owned by or Chemyx NanoJet Series User Manual Chemyx Inc. 10905 Cash Road Stafford, TX 77477 USA www.chemyx.com Intellectual Property All Intellectual Properties, as defined below, owned by or which is otherwise the

More information

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL

BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL BENCH-TOP DIGITAL MULTIMETER INSTRUCTION MANUAL SK-4033 / SK-4035 Thank you for purchasing KAISE MODEL SK-4033/4035 BENCH-TOP DIGITAL MULTIMETERS. To obtain the maximum performance of this instrument,

More information

Variable Temperature Digital Solder and Testing Station

Variable Temperature Digital Solder and Testing Station Variable Temperature Digital Solder and Testing Station Model: DSTS User Manual To avoid electric shock or injury, read the following carefully before using. 1. This appliance is only for household use.

More information

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions.

WARNING: Do not use the thermometer/data logger before you read the users manual and the following instructions. 55 This unit passes the following tests EN 61326-1:2006 (CISPR11,IEC/EN 61000-3-2:2006, IEC/EN 61000-3-3: 1995+A1 :2001+A2:2005 IEC/EN 61000-4-2/-3/-5/-6/-11) WARNING: Do not use the thermometer/data logger

More information

Instruction Manual HI 9033 HI Waterproof Multi-Range EC and TDS Meters for Field Applications.

Instruction Manual HI 9033 HI Waterproof Multi-Range EC and TDS Meters for Field Applications. Instruction Manual HI 9033 HI 9034 Waterproof Multi-Range EC and TDS Meters for Field Applications www.hannainst.com PRELIMINARY EXAMINATION Dear Customer, Thank you for choosing a HANNA instruments product.

More information

pumps Pump 11 Plus, see page 8 EC Pump 33, see page 14 PHD 22/2000 Hpsi, see page 20

pumps Pump 11 Plus, see page 8 EC Pump 33, see page 14 PHD 22/2000 Hpsi, see page 20 pumps Pump 11 Plus, see page 8 Products Page No. Pump Selection Guide 2-7 Syringe Pumps 8-22 Applications 23-27 Software & Drivers 28-29 Accessories 30 OEM Pumps 31-37 Peristaltic Pumps 38-42 Blood Pumps

More information

Model 44 Syringe Pump Series User s Manual. Model 44 Programmable

Model 44 Syringe Pump Series User s Manual. Model 44 Programmable Model 44 Syringe Pump Series User s Manual Model 44 Programmable 55-1144 1 Table of Contents SUBJECT PAGE NO. Table of Contents...1 General Information Warranty and Repairs...2-3 Technical Specifications...4-5

More information

CHEMYX. Fusion Touch User Manual. Chemyx Inc Greenbriar suite D Stafford, TX

CHEMYX. Fusion Touch User Manual. Chemyx Inc Greenbriar suite D Stafford, TX CHEMYX Fusion Touch User Manual Chemyx Inc. 4003 Greenbriar suite D Stafford, TX 77477 www.chemyx.com Intellectual Property All Intellectual Properties, as defined below, owned by or which is otherwise

More information

Quick Start Guide. Liquid Dosing Pump. Register your new product today at

Quick Start Guide. Liquid Dosing Pump. Register your new product today at Quick Start Guide Liquid Dosing Pump Register your new product today at www.coralvue.com/register Congratulations on your purchase of an IceCap Liquid Dosing Pump! Please read this entire Quick Start Guide

More information

Mitos P-Pump. product datasheet

Mitos P-Pump. product datasheet product datasheet page Product description 2 Main benefits 3 Why choose the Mitos P-Pump? 3 Closed-loop flow control 4 Product specifications 5 Accessories - overview 6 Mitos P-Pump Basic 7 Mitos P-Pump

More information

Orbital shaker PSU-10i

Orbital shaker PSU-10i Orbital shaker PSU-10i For version V.3GW Contents 1 Safety...3 2 General Information...5 3 Getting Started...6 4 Operation of PSU-10i...7 5 Specifications...8 6 Guarantee and service...10 Page 2 1. Safety

More information

High Efficiency LED Driver DCCP-DPR Series USER MANUAL. This manual offers important information and suggestions with

High Efficiency LED Driver DCCP-DPR Series USER MANUAL. This manual offers important information and suggestions with EPSOLAR High Efficiency LED Driver DCCP-DPR Series USER MANUAL Thank you very much for selecting our DCCP-DPR LED Driver product! This manual offers important information and suggestions with respect to

More information

Version: Document Number: V1.0.2 NS A5 Receiving Card Product Description XI'AN NOVASTAR TECH CO.,LTD

Version: Document Number: V1.0.2 NS A5 Receiving Card Product Description XI'AN NOVASTAR TECH CO.,LTD Version: Document Number: V1.0.2 NS110100303 A5 Receiving Card Change History Version Publish Date Description V1.0.2 2017-06-22 Optimized the document structure and content. V1.0.1 2016-10-26 Optimized

More information

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this

OPERATION MANUAL. Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER. Model : SL-4113G. Your purchase of this Green power, Hybrid power Auto range, A/C weighting SOUND LEVEL METER Model : SL-4113G Your purchase of this SOUND LEVEL METER marks a step forward for you into the field of precision measurement. Although

More information

Fog machine PT Users Manual

Fog machine PT Users Manual Fog machine PT-1500 Users Manual Table of content 1. Safety instructions... 3 1.1. For safe and efficient operation... 3 2. Intended use of the device... 4 2.1. Overhead installation... 5 2.2. Electrical

More information

RESS. Manual. Rotary-Ball-Camera Pro. The Producer. Visual Inspection Sweep Instruments Measuring Instruments

RESS. Manual. Rotary-Ball-Camera Pro. The Producer. Visual Inspection Sweep Instruments Measuring Instruments RESS The Producer Visual Inspection Sweep Instruments Measuring Instruments Manual Rotary-Ball-Camera Pro Summary of the contents Rotary-Ball-CameraPro 1. Commissioning 2. Safety Notes 3. Working with

More information

Advanced Camcorder Support System. Instruction Manual

Advanced Camcorder Support System. Instruction Manual Advanced Camcorder Support System Instruction Manual PAG ORBITOR Advanced Camcorder Support System Instruction Manual CONTENTS SECTION PAGE 1 SAFETY 2 2 ASSEMBLY & OPERATION 3 3 PARTS AND ASSEMBLIES 9

More information