Slide 0 Welcome to the Support and Maintenance chapter of the ETERNUS DX90 S2 web based training.

Size: px
Start display at page:

Download "Slide 0 Welcome to the Support and Maintenance chapter of the ETERNUS DX90 S2 web based training."

Transcription

1 Slide 0 Welcome to the Support and Maintenance chapter of the ETERNUS DX90 S2 web based training. 1 This module introduces support and maintenance related operations and procedures for the ETERNUS DX60 S2. Some of the sections are focusing on those functions of the built-in ETERNUS Web GUI that are needed for typical maintenance procedures, whereas some sections describe useful functions for daily technical support work. 2 This first chapter focuses on those functions that are typically needed for standard Maintenance Operations. These functions can be found from the Device Status menu. 3 This screen we have already seen couple of times in the previous chapters. On this screen you can see the overall status of the Controller Enclosure and of the Drive Enclosure, if there is one attached to the system. Should any component in the Controller or Drive Enclosure have an error, it would be indicated here. On this screen it is possible to confirm the status of each device and component by clicking on the item of interest, after which all the related information will be shown. The Maintenance Operations are conducted from this screen, for each device or component of the system; functions like Replace or Force Disable are shown on the bottom right corner of the screen. The available functions depend on the component being selected and its current status. 4 As already mentioned in the Hardware and Software Installation chapter, the ETERNUS DX60 S2 can indicate need for preventive maintenance by changing the system status from Normal to Warning and showing which component is in need of preventive maintenance. This function is applicable to all those components that are available as spare parts. Preventive maintenance aims to prevent component failures before they occur by suggesting a parts replacement prior to the failure. The system mode must be set to Maintenance before starting preventive maintenance actions. 5 With the Force Disable function, you can force a detachment of a component, in other words force the system to a degraded state. Force Disable can be used to detach a component which for example has not reached a normal status after a service procedure. Force Disable can be executed on any component regardless of its current status. 6 Opposite to what we can do with the Force Disable, with the Force Enable we can attach a component to the system by forcing the component to reboot.

2 For example, if during a service procedure we have removed from the system a component due to a failure of another component, the Force Reboot can be used reattach the component. 7 If you want to permanently remove a disk from the system due to a defect or if you for example have unused disk or disks in one ETERNUS system and you want to use them in another ETERNUS system, the disks can detached from the system using the Reduce Disk function. Please note that functional disks must not be removed by simply pulling them out, this function must always be used when removing a disk from the system. 8 To physically locate the system or its particular module you can enable the Identify LED. On the Controller Module and Drive Enclosure the LED is located in the Operation Panel on the left hand side of the front panel. The Identity LEDs of the CMs and PSUs are visible in the backside of the unit. When activated this LED is blinking in blue. 9 The RAID Group Status screen shows the list of RAID Groups and the detailed information of each registered RAID Group. This function provides System Administrators and Maintenance Engineers an overview of the RAID Groups and the Logical Volumes assigned to the RAID Groups. Also an ongoing Rebuild or Copy Back and Expand progress is shown here. 10 On the Volume Status screen you can see the status of each Volume registered in the device; if a Volume is being currently formatted or migrated it is shown here. 11 Next we will have a look at the Maintenance Utilities which are available under the menu Maintenance. 12 This function sets the system to a Maintenance mode, which means that remote reporting is deactivated, Sense Information is ignored and the status LEDs are disabled. This enables maintenance work on the system without generating any unnecessary error messages. It is very important to set the system back to "Normal" mode after the maintenance procedures are finished, in the last chapter of this module we will see how to do that. 13 The Add Drive Enclosure function of the Hardware Maintenance menu provides the possibility to add a Drive Enclosure to the system without having to switch the system off. This functionality is naturally only available with the 3.5 inch Controller Module. 14

3 The Remove Drive Enclosure is obviously the opposite function to adding a Drive Enclosure. A prerequisite for a removal of a Drive Enclosure is that all disks in it are unused, meaning, not allocated to a RAID Group. 15 If the system has only one Controller Module fitted, a second CM can be added with the Add Controller Module function. If there is Drive Enclosure attached to the Controller Enclosure, it makes obviously sense to fit at the same time a second SAS Expansion Module to the DE d-e]. In this case both the Controller Module and the Expansion Module are added to the system in one go. 16 This function deletes all statistical information and sense data, meaning internal system data which has not been reported to the host. Always after having put the system in Maintenance Mode for maintenance procedures that might cause the system to generate error notifications, it is recommended to delete the sense data. 17 In this chapter we will have a look at the different options the ETERNUS DX60 S2 offers to view various log information of the system and how to export this information for further analysis and reporting. 18 Through the Event Log menu you can access the event log of the system. The event log can hold up to 400 events. When the system log reaches this limit the older events are automatically deleted as new events are recorded. There are different types of log instances - Information, Warnings, Errors and Maintenance related - like the ones that we see here: creation or deletion of RAID Groups, system status related and component failures. Individual log entries can also be deleted here. The Event Log is held separate from the internal device logs, meaning that deleting an internal device log will not erase the Event Log and vice versa. 19 Panic Dump is a copy of the system operating memory content of the Controller Module at the time when a failure occurred. This memory dump can be used to analyze the cause of the failure. The dump file can be saved in various file sizes which enables for example use of floppies or providing a convenient file size for an attachment. On this screen it is also possible to delete a specific Panic Dump. For each Controller Module a maximum of two Panic Dumps can be held, if more CM failures occur, the latest and the oldest will be held. In other words, from four occurred CM failures the first and the fourth are held. 20 From the Error Information menu it is possible to see an overview of the Disk Errors and Port Errors. This information can be very useful to identify degradation or early failure signs of the system components.

4 21 The Export Log function allows exporting the internal maintenance information log for recording the device maintenance history or for further problem analysis. As already mentioned by the Panic Dump, with "Log File Size" it is possible to define the maximum size of each block of log to be exported: the default size of 4.27 Megabytes produces the smallest amount but biggest size of files, whereas the other options produce smaller file sizes but respectively a larger number of files. Here one should select the file size which best suites the consequent handling of the log data. With this function it is also possible to delete chosen parts of the log information. 22 This function saves the configuration information of the ETERNUS DX60 S2 in a file that has an extension cfg. This file can be consequently used as a configuration file to copy a system configuration to other ETERNUS systems with identical hardware configuration. The file can also be used as a recovery file if problems are experienced after the configuration is changed, therefore it is recommended to export the configuration file before making changes to the system hardware configuration. 23 On this screen it is possible to see - and if wanted, to export - the G-List, or Grown Defect List, which is a list of disk related errors saved on each disk's disk management area. Please note that disk access from the Host must be prevented when extracting the G-List. 24 In this next chapter we will get ourselves familiar with some further system related utilities. There are utilities for system shutdown, shutdown and restart, and for initializing a system disk. The Cache utilities allow us to manage pinned data and to force a cache write back. Recovery utilities provide us several possibilities to recover the system if configuration related problems should occur. Setting up manually which Controller Module has the Master role can be done with the "Change Master CM" function. Furthermore, Diagnosis utilities provide the possibility to diagnose the disks and the RAID Groups. 25 For a remote shutdown and or restart in the case the front panel power switch has an error or the system hangs, this function provides the possibility to restart the system or to power it down. 26 Initialize system disk prepares a system disk - drive zero or one - for use in the ETERNUS DX60 S2. This function initializes all firmware archives, system logs and Panic dumps. After initializing a system disk it is necessary to register the active firmware. Failing to do that would for example cause problems with Controller Module maintenance and when attaching a second Controller Module or with Drive Enclosure expansion.

5 27 This function is for writing back or deleting "pinned data" generated in the device cache area. Pinned data is the data left in the cache due to unsuccessful write-back to the disk drive from the cache area. This can be caused for example when a RAID Group has not been accessible because of a power failure. 28 If the user data could not be written to the data disk from the cache area, this function forcibly writes back all the user data left in the cache area. 29 First of the Recovery utilities that we will have a look at is the Apply Configuration function. A system configuration can be restored from three different sources: From one of the three latest automatically saved configurations. From one of the four user defined backup configurations - following page shows how to back up the configuration - or from a configuration file which has been exported with the "Export Configuration" function as explained in the previous chapter. Choosing "Restore" as the apply mode would apply one of the above configurations, choosing "Initialize" would not only apply the above configuration but also reset the configuration insofar that the Volumes need to be formatted after the system has been once power cycled. 30 With the "Backup Configuration" function one can permanently save, or backup, a configuration. Like mentioned on the previous page, the configuration can be later restored should problems occur after a system configuration change - therefore it is recommended to always take copy of the system configuration before applying any changes to the configuration. 31 With this screen you can resolve a problem situation that is caused by a system problem which has occurred either during power down or power up. Backup Fail refers to a system status that has been caused by an error that occurred at power failure or during the power down sequence. Restore Fail is the status that results when the system is not able to complete the power on sequence because of an error at power on. In both cases, even if the cause of the error has been rectified, it may happen that the system does not come back to status "Normal". In such cases, clicking on Reset clears the Backup Fail or Restore Fail status. 32 If any abnormality is detected during the power on sequence, the device status is set to Not Ready and consequently no I/O can be received from the host. In this situation the user data saved in the system disk from the cache memory will not be restored back to the system cache memory. This function can be used to forcibly restore this user data to the system cache memory and thus avoid any loss of data. After clearing the cause of the problem, execute Force Restore by clicking on "Restore" and power off/on the device.

6 33 Should the very unlikely situation occur that an ETERNUS DX60 S2 with dual controller configuration looses one controller and panics at the same time, the system may end up with a status Machine Down. Consequently all Host paths are shut in order to save the Dirty Data, which refers to data inconsistency caused by data not having been synchronized between a RAID Group and the system cache. In order to avoid data loss, a system in Machine Down status cannot be switched off. Executing the "Reset Machine Down Recovery" function resets the status and allows the machine to be powered off and restarted again. 34 With this function it is possible to reboot the Controller Module or Modules fitted in the system, a reboot will be performed in 30 seconds after executing this function. 35 The Change Master CM function gives us the option to manually choose which of the two fitted Controller Modules has the role Master. To use this function, choose the CM which currently has the role Slave. The following page shows the roles of the CMs during maintenance operations and the possible ways to connect an ETERNUS and the management server or PC. 36 For the maintenance operations the management server or PC must be connected to the CM that has the Master role. This connection can be done either by direct connection, or by using a switch or a hub. Please note that only the networked connection is redundant. When connected over a network and the link to the Master CM goes down, the Slave takes over the Master role and its IP address automatically. A further option is to set an IP address for the Slave Controller Module in the "Set Network Environment" menu, in which case the Slave Controller takes over the functionality of the Master CM automatically if the LAN link to the Master CM goes down. 37 First of the two available Diagnosis utilities is the Disk Diagnosis. This function checks the state and the condition of the selected disks. Please note that the disks being diagnosed must not be in other use during the diagnosis, meaning there should be no Host access, migration, RAID Group change or similar in progress. After having chosen which disks to diagnose - the options are "All Disks", "Unused Disks", "Selected Disks" and "Selected Drive Enclosures" - the diagnose can be started. Depending on the number of disks and their capacities the diagnosis can take a longer or shorter time, after which the results are shown. 38 Similarly as the utility on the previous page is for diagnosing a disk or disks in the system, the RAID Group Diagnosis utility is for diagnosing the existing RAID Groups. This utility is especially useful when for example a disk multi-dead status has occurred after "All Controller Module Panic" and one wants to ensure the reliability of the RAID Group before restoring the data.

7 39 The Maintenance Procedures chapter introduces us to the Maintenance and Status LEDs, how to put the system in maintenance mode and what needs to be done before starting with Hot Maintenance procedures. 40 There is a General Status LED on the left hand side of the front panel. When the system is fully functional the status LED lights green. The other LED showing information about the system status is the general Fault LED. 41 In addition to the general Status, there are also LEDs on each module. These LEDs are named STS; when the LED is green the system is running normal. If a LED lights steady in orange then the module in question needs attention and typically needs to be replaced. 42 In the beginning of the chapter Maintenance Utilities we mentioned that before executing functions like add or remove Drive Enclosure the system needs to be set in Maintenance Mode. The purpose of the Maintenance Mode is to stop unnecessary external reporting You can verify the system status from the Device Status Menu 43 This brings us to the last chapter of this module. In this chapter we will have a look at the procedures and practices related to parts replacement, handling of system internal information and how to stop the Maintenance Mode and exit the GUI. 44 Let's see how to proceed when we want to do a hot replacement - meaning parts replacement without switching the system off - for the Controller Module one. First we choose Menu "Status" and Sub Menu "Device Status". Next we click on Controller Module 1, please notice the red symbol indicating a component error. The component can be replaced when the red symbol is shown, if the component has a status "Normal" or "Warning", it would be necessary first to "Force Disable" the component before proceeding. 45 After having enabled the hot replacement, the part can be replaced as per the instructions given in the Maintenance Manual. The table shows the typical times needed for a component replacement. Having replaced the component its status changes to show if the replacement was successful. 46 As mentioned on the previous page, after the replacement the component status must change from Maintenance to Normal. 47

8 If the replaced component was the only defective component in the system, the next step in the replacement procedure is to "Delete Sense Data". This prevents the error data that has potentially been generated by ETERNUS during the maintenance procedure from being sent out. 48 It is a good practice to collect the ETERNUS system internal logs after all maintenance work, as already mentioned in the chapter "Log and Dump Management", we can export the file in various file sizes. 49 In case of a Controller Module replacement, we recommend taking Panic Dump for analyzing the cause of failure. 50 As the last step of the replacement procedure it is important to stop the Maintenance Mode, this can be done from the "Start/End Maintenance" Menu. Always confirm from the "Device Status" Menu that the system returns back to "Normal" Mode. 51 After that we finish off our maintenance tasks by logging out of the GUI, however, before doing that we want to make absolutely sure that the system runs fully functional when we leave the customer site. To do that, we check the Device Status, the status of the RAID Groups and the status of all Volumes. We also check that the System LED on the left hand side of the front panel lights green. Only after that we log ourselves out of the system by clicking on "Logoff". 52 Here are useful links for reference documentation and additional information regarding the subjects covered in this training module. 53 That brings us to the end of this web based training module. Thank you for your attention.

ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2

ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 Support and Maintenance Support and Maintenance ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 0 Content Maintenance Utilities Maintenance Operations Log

More information

10 Having Hot Spare disks available in the system is strongly recommended. There are two types of Hot Spare disks:

10 Having Hot Spare disks available in the system is strongly recommended. There are two types of Hot Spare disks: 0 This Web Based Training module provides support and maintenance related information for the ETERNUS DX S2 family. This module provides an introduction to a number of ETERNUS Web GUI functions, for a

More information

17 In big Data Centers it may be practical to collect event and error messages to a central syslog server.

17 In big Data Centers it may be practical to collect event and error messages to a central syslog server. Slide 0 Welcome to this Web-Based-Training session providing you an introduction to the Initial Setup of the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2. 1 In this first chapter we will look at the

More information

This symbol points out hazards that can lead to non-functional configurations, data loss, equipment damage or even personal injury.

This symbol points out hazards that can lead to non-functional configurations, data loss, equipment damage or even personal injury. PRACTICAL EXERCISE Exercise Exercise number 9 Objective Upgrade the System Firmware Target time 30 minutes Release October 2011 Pages 10 This exercise provides step-by-step instructions to a firmware update.

More information

Installing the IBM ServeRAID Cluster Solution

Installing the IBM ServeRAID Cluster Solution Installing the IBM ServeRAID Cluster Solution For IBM Netfinity ServeRAID-4x Ultra160 SCSI Controllers Copyright IBM Corp. 2000 1 2 IBM Netfinity Installing the IBM ServeRAID Cluster Solution Chapter 1.

More information

ETERNUS DX60 and DX80

ETERNUS DX60 and DX80 Highlights Low environmental impact Highly scalable & versatile connectivity User friendly management systems Outstanding reliability 1 Overview (1) are designed to meet the needs of all environments from

More information

ETERNUS DX80 S2 and DX90 S2. Hardware Installation

ETERNUS DX80 S2 and DX90 S2. Hardware Installation Content Package Contents Rack Mounting Power Cabling Backend Cabling QSFP Power On Procedure Power Off Procedures Operator Panel - Function Button 1 Package Contents (1) Controller Enclosure Kit Installation

More information

ETERNUS DX Advanced Copy Functions

ETERNUS DX Advanced Copy Functions ETERNUS DX Advanced Copy Functions 0 Content Equivalent Copy (EC) Session in General Equivalent Copy (EC) Concept EC Concept Diagram EC Cancel, Suspend and Resume Equivalent Copy - Process Mirroring Mechanisms

More information

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak

Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak Version 5b Offline Array Recovery Procedures SuperTrak SX6000 and UltraTrak This document describes the procedures for protecting data and restoring array status to arrays that have gone OFFLINE. Promise

More information

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu.

Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. Slide 0 Welcome to this Web Based Training session introducing the ETERNUS DX80 S2, DX90 S2, DX410 S2 and DX440 S2 storage systems from Fujitsu. 1 This training module is divided in six main chapters.

More information

Technical Guide Network Video Recorder Enterprise Edition Maintenance Guide

Technical Guide Network Video Recorder Enterprise Edition Maintenance Guide Technical Guide Network Video Recorder Enterprise Edition Maintenance Guide Network Video Management System March 23, 2018 NVMSTG008 Revision 1.3.0 CONTENTS 1. Overview... 3 1.1. About This Document...

More information

That is achieved by having a CM Expander in each CM and by providing an internal cross connection between the CMs and their CM Expanders. Should one C

That is achieved by having a CM Expander in each CM and by providing an internal cross connection between the CMs and their CM Expanders. Should one C 0 The ETERNUS DX is a seamless product family, providing data center class features from Entry to Enterprise models. This ETERNUS DX Web Based Training module provides a technical introduction to the features

More information

Storage Systems Storage Systems Copyright 2018 Stone Computers Ltd. All Rights Reserved. 2

Storage Systems Storage Systems Copyright 2018 Stone Computers Ltd. All Rights Reserved. 2 Storage Systems Copyright 2018 Stone Computers Ltd. All Rights Reserved. 2 Dothill Storage Systems Copyright 2018 Stone Computers Ltd. All Rights Reserved. 3 Connecting to a Dothill Storage System' Management

More information

The USB connector can be used for firmware updates and storing the Library configuration.

The USB connector can be used for firmware updates and storing the Library configuration. Slide 0 Welcome to this Fujitsu Web Based Training. This module provides a technical introduction to the ETERNUS LT Tape Libraries. There are three models; LT 20 S2, LT40 S2 and LT60 S2. The model designation

More information

High-reliability, High-availability Cluster System Supporting Cloud Environment

High-reliability, High-availability Cluster System Supporting Cloud Environment High-reliability, High-availability Cluster Supporting Cloud Environment Seishiro Hamanaka Kunikazu Takahashi Fujitsu is offering FUJITSU Software, a high-reliability software platform that supports the

More information

10 The next chapter of this Web Based Training module describe the two different Remote Equivalent Transfer Modes; synchronous and asynchronous.

10 The next chapter of this Web Based Training module describe the two different Remote Equivalent Transfer Modes; synchronous and asynchronous. Slide 0 Welcome to this Web Based Training session providing an introduction to the fundamentals of Remote Equivalent Copy. This is one of the ETERNUS DX Advanced Copy Functions available in Fujitsu ETERNUS

More information

NEC Express5800 Series. StorView Ver. 3. Operation Guide. for N F B

NEC Express5800 Series. StorView Ver. 3. Operation Guide. for N F B NEC Express5800 Series StorView Ver. 3 Operation Guide for N8190-121F Trademarks NEC ESMPRO is the registered trademark of NEC Corporation. Microsoft, Windows are registered trademarks or trademarks of

More information

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL

PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL PROMISE ARRAY MANAGEMENT ( PAM) USER MANUAL Copyright 2002, Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced or transmitted

More information

RAID EzAssist Configuration Utility User Reference Guide

RAID EzAssist Configuration Utility User Reference Guide RAID EzAssist Configuration Utility User Reference Guide DB13-000047-00 First Edition 08P5519 Proprietary Rights Notice This document contains proprietary information of LSI Logic Corporation. The information

More information

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2

Taurus Super-S3 LCM. Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.2 Dual-Bay RAID Storage Enclosure for two 3.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.2 www.inxtron.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 Technical Specifications...

More information

The term "physical drive" refers to a single hard disk module. Figure 1. Physical Drive

The term physical drive refers to a single hard disk module. Figure 1. Physical Drive HP NetRAID Tutorial RAID Overview HP NetRAID Series adapters let you link multiple hard disk drives together and write data across them as if they were one large drive. With the HP NetRAID Series adapter,

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.0 SAS to SAS/SATA JBOD Subsystem Revision 1.0 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Terminologies... 6 Chapter 2 Getting Started... 7 2.1 Unpacking

More information

EClass. SR2.2 Release Notes. Release Notes Document. Version 1.02 Date: 08/09/2007. Copyright 2007, Promise Technology, Inc. All Rights Reserved

EClass. SR2.2 Release Notes. Release Notes Document. Version 1.02 Date: 08/09/2007. Copyright 2007, Promise Technology, Inc. All Rights Reserved EClass SR2.2 Release Notes Release Notes Document Version 1.02 Date: 08/09/2007 Copyright 2007, Promise Technology, Inc. All Rights Reserved Revision Date Release Label Revision History Release Version

More information

Technical Guide Network Video Recorder Standard Edition Maintenance Guide

Technical Guide Network Video Recorder Standard Edition Maintenance Guide Technical Guide Network Video Recorder Standard Edition Maintenance Guide Network Video Management System November 14, 2017 NVMSTG009 Revision 1.2.0 CONTENTS 1. Overview... 3 1.1. About This Document...

More information

Hot Standby Configuration Guide

Hot Standby Configuration Guide Version 1.1 Date: November 4, 2016 Yeastar Information Technology Co. Ltd. 1 Contents Hot Standby Introduction... 3 Hot Standby Scenario... 3 Precondition... 3 Setup Hot Standby... 4 Hot Standby Failover

More information

Installation and User's Guide

Installation and User's Guide IBM Netfinity High-Availability Cluster Solutions Using the IBM ServeRAID -3H and IBM ServeRAID-3HB Ultra2 SCSI Controllers Installation and User's Guide IBM IBM IBM Netfinity High-Availability Cluster

More information

CMS Failover White Paper. Surveillance Station and above

CMS Failover White Paper. Surveillance Station and above CMS Failover White Paper Surveillance Station 8.0.0 and above 1 Table of Contents Introduction 3 Overview Failover Framework Flexible Failover Settings Migration of Device Licenses Downtime Failover Setup

More information

Design Guide (Basic) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems. System configuration design

Design Guide (Basic) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems. System configuration design FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Design Guide (Basic) System configuration design Table of Contents 1. Function Overview 14 2. Basic Functions

More information

AssuredSAN Event Descriptions Reference Guide

AssuredSAN Event Descriptions Reference Guide AssuredSAN Event Descriptions Reference Guide Abstract This guide is for reference by storage administrators to help troubleshoot storage-system issues. It describes event messages that may be reported

More information

Upgrading the Server Software

Upgrading the Server Software APPENDIXB This appendix describes how to upgrade or reinstall the Cisco PAM server software, desktop client software, and Gateway module firmware. Contents Upgrade Notes for Release 1.5.0, page B-2 Obtaining

More information

Taurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1

Taurus Mini Super-S3. Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives. User Manual March 31, 2014 v1.1 Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives User Manual March 31, 2014 v1.1 EN Table of Contents Table of Contents 1 Introduction... 1 1.1 System Requirements... 1 1.1.1 PC

More information

HPE ProLiant Gen9 Troubleshooting Guide

HPE ProLiant Gen9 Troubleshooting Guide HPE ProLiant Gen9 Troubleshooting Guide Volume II: Error Messages Abstract This guide provides a list of error messages associated with HPE ProLiant servers, Integrated Lights-Out, Smart Array storage,

More information

3 Here is a short overview of the specifications. A link to a data sheet with full specification details is given later in this web based training

3 Here is a short overview of the specifications. A link to a data sheet with full specification details is given later in this web based training 1 Welcome to this web based training session. This presentation provides you an introduction to the Fujitsu ETERNUS JX40. The JX40 is a passive direct server attached drive extension offering extension

More information

Monitoring ETERNUS DX systems with ServerView Operations Manager

Monitoring ETERNUS DX systems with ServerView Operations Manager User Guide - English FUJITSU Software ServerView Suite Monitoring ETERNUS DX systems with ServerView Operations Manager Edition February 2018 Comments Suggestions Corrections The User Documentation Department

More information

iscsi sub-system event log

iscsi sub-system event log iscsi sub-system event log lntroduction The Event log records the information about the iscsi sub-system. This document will describe how to analyze the event log and provide insight on how to deal with

More information

StoreOnce software revision (BB ) release notes

StoreOnce software revision (BB ) release notes StoreOnce software revision 3.14.1 (BB943-10504) release notes Abstract This document describes the StoreOnce System 3.14.1 software release, BB943-10504.rpm. This is a mandatory upgrade for the products

More information

Taurus Mini Super-S LCM

Taurus Mini Super-S LCM Dual-Bay RAID Storage Enclosure for two 2.5-inch Serial ATA Hard Drives User Manual August 1, 2011 v1.0 www.akitio.com EN Table of Contents Table of Contents 1 Introduction... 1 1.1 System Requirements...

More information

SAS JBOD Installation Reference Guide Revision 1.0

SAS JBOD Installation Reference Guide Revision 1.0 SAS JBOD 16-bay Rackmount Enclosure Installation Reference Guide Revision 1.0 P/N: PW0020000000281 Copyright No part of this publication may be reproduced, stored in a retrieval system, or transmitted

More information

2012 Lenovo Server Client Performs All Steps from ISP Machine 1. Check the ISP CD/DVD drive and remove any disks that are currently loaded.

2012 Lenovo Server Client Performs All Steps from ISP Machine 1. Check the ISP CD/DVD drive and remove any disks that are currently loaded. 2012 Lenovo Server Client Performs All Steps from ISP Machine 1. Check the ISP CD/DVD drive and remove any disks that are currently loaded. 2. Log onto the Windows side of the ISP and go to the QsrSoft

More information

Dell DL4300 Appliance Release Notes

Dell DL4300 Appliance Release Notes Dell DL4300 Appliance Release Notes Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates either potential

More information

Product Release Notes

Product Release Notes Product Release Notes ATTO Configuration Tool v3.38 - Windows 1. General Release Information The ATTO Configuration Tool helps you customize the settings of your ATTO storage Controller to maximize the

More information

AMD RAID Installation Guide

AMD RAID Installation Guide AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 7 / 7 64-bit / Vista TM / Vista TM 64-bit /

More information

Introduction. Storage Failure Recovery Logging Undo Logging Redo Logging ARIES

Introduction. Storage Failure Recovery Logging Undo Logging Redo Logging ARIES Introduction Storage Failure Recovery Logging Undo Logging Redo Logging ARIES Volatile storage Main memory Cache memory Nonvolatile storage Stable storage Online (e.g. hard disk, solid state disk) Transaction

More information

Managing Configurations

Managing Configurations CHAPTER 3 The Configurations page is your starting point for managing device configurations for network elements managed by Cisco Prime Network by using the CM tools. The following table lists the main

More information

PowerVault MD3 Storage Array Enterprise % Availability

PowerVault MD3 Storage Array Enterprise % Availability PowerVault MD3 Storage Array Enterprise 99.999% Availability Dell Engineering June 2015 A Dell Technical White Paper THIS WHITE PAPER IS FOR INFORMATIONAL PURPOSES ONLY, AND MAY CONTAIN TYPOGRAPHICAL ERRORS

More information

NAS System. User s Manual. Revision 1.0

NAS System. User s Manual. Revision 1.0 User s Manual Revision 1.0 Before You Begin efore going through with this manual, you should read and focus on the following safety guidelines. Information about the NAS system s packaging and delivery

More information

Lenovo RAID Introduction Reference Information

Lenovo RAID Introduction Reference Information Lenovo RAID Introduction Reference Information Using a Redundant Array of Independent Disks (RAID) to store data remains one of the most common and cost-efficient methods to increase server's storage performance,

More information

ERserver. Service provider information Service functions

ERserver. Service provider information Service functions ERserver Service provider information Service functions ERserver Service provider information Service functions Note Before using this information and the product it supports, be sure to read the information

More information

HP OpenView Storage Data Protector A.05.10

HP OpenView Storage Data Protector A.05.10 HP OpenView Storage Data Protector A.05.10 ZDB for HP StorageWorks Enterprise Virtual Array (EVA) in the CA Configuration White Paper Edition: August 2004 Manufacturing Part Number: n/a August 2004 Copyright

More information

Upgrading R/Evolution Storage Systems

Upgrading R/Evolution Storage Systems Upgrading R/Evolution Storage Systems This guide describes considerations and procedures for upgrading the following R/Evolution storage systems: 2000 Series to 2002 Series storage systems 2000 Series

More information

RocketRAID 2720C2. User Manual V1.00

RocketRAID 2720C2. User Manual V1.00 RocketRAID 2720C2 User Manual V1.00 Nov. 6, 2013 1 Table of contents 1. HighPoint RocketRAID 2720C2 -Cross-Synch Storage Solution... 3 2. Kit Contents... 3 3. Installing the RocketRAID 2720C2 Host Adapters...

More information

Dell EMC ME4 Series Storage Systems. Release Notes

Dell EMC ME4 Series Storage Systems. Release Notes Dell EMC ME4 Series Storage Systems Release Notes Notes, cautions, and warnings NOTE: A NOTE indicates important information that helps you make better use of your product. CAUTION: A CAUTION indicates

More information

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide

High Density RocketRAID EJ6172 Device Board Data RAID Installation Guide High Density RocketRAID 2711 + EJ6172 Device Board Data RAID Installation Guide Introduction The HighPoint High Density Storage Solutions hammer down high density storage cost over a single mini- SAS port.

More information

Drobo B810n Getting Started Guide

Drobo B810n Getting Started Guide Drobo B810n Getting Started Guide Table of Contents 1: Before You Begin... 4 1.1 Product features at a glance... 4 1.2 Checking box contents... 5 1.3 Checking system requirements... 5 1.4 Checking hardware

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.2 SAS to SAS/SATA JBOD Subsystem Revision 1.2 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Subsystem... 6 1.4 Identifying Parts

More information

Barracuda Message Archiver Panel Indicators, Ports, and Connectors

Barracuda Message Archiver Panel Indicators, Ports, and Connectors Barracuda Message Archiver Panel Indicators, Ports, and Connectors This article refers to Barracuda Message Archiver firmware firmware version 5.0 or higher. The illustrations in this article are based

More information

RocketStor 6328 Thunderbolt 2 RAID Host Adapters User s Guide for Mac

RocketStor 6328 Thunderbolt 2 RAID Host Adapters User s Guide for Mac RocketStor 6328 Thunderbolt 2 RAID Host Adapters User s Guide for Mac Revision: 1.00 Mar. 12, 2014 HighPoint Technologies, Inc. 1 Table of Contents 1. HighPoint RocketStor 6328.3 2. System Requirement

More information

ThinkSystem SR650 Messages and Codes Reference

ThinkSystem SR650 Messages and Codes Reference ThinkSystem SR650 Messages and Codes Reference Machine Types: 7X05 and 7X06 Note Before using this information and the product it supports, be sure to read and understand the safety information and the

More information

Self-encrypting drives (SED): helping prevent data loss, theft, and misplacement

Self-encrypting drives (SED): helping prevent data loss, theft, and misplacement Self-encrypting drives (SED): helping prevent data loss, theft, and misplacement White paper Version: 1.1 Updated: Sep., 2017 Abstract: This white paper introduces Infortrend self-encrypting drive technology,

More information

Your Challenges, Our Solutions. The NAS and/or laptop storage are not enough; how can I upgrade once and expand all?

Your Challenges, Our Solutions. The NAS and/or laptop storage are not enough; how can I upgrade once and expand all? Your Challenges, Our Solutions The NAS and/or laptop storage are not enough; how can I upgrade once and expand all? How to expand painlessly to keep the data flow? While personal data is growing on both

More information

3ware Release Notes Supporting 9690SA and 9650SE controllers

3ware Release Notes Supporting 9690SA and 9650SE controllers 3ware 9.5.2 Release Notes Supporting 9690SA and 9650SE controllers READ ME FIRST! Final Introduction Thank you for purchasing 3ware SAS and SATA RAID controllers. This document describes important recommendations

More information

SOFTWARE GUIDE VT-100. imageraid Series Storage System. (Text-based User Interface)

SOFTWARE GUIDE VT-100. imageraid Series Storage System. (Text-based User Interface) SOFTWARE GUIDE VT-100 imageraid Series Storage System (Text-based User Interface) SOFTWARE GUIDE VT-100 imageraid Series Storage System (Text-based User Interface) Fujitsu Europe Limited Restricted Rights

More information

RocketRAID 2840A. SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller. User s Guide v1.0

RocketRAID 2840A. SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller. User s Guide v1.0 RocketRAID 2840A SAS 6Gb/s PCI-Express 3.0 x8 RAID Controller User s Guide v1.0 1 Table of Contents 1. HighPoint RocketRAID 2840A Overview... 3 2. Board Layout & Hardware Installation... 4 3. Using the

More information

ReadyNAS OS 6 Desktop Storage Systems

ReadyNAS OS 6 Desktop Storage Systems ReadyNAS OS 6 Desktop Storage Systems Hardware Manual Models: 102 104 312 314 350 East Plumeria Drive San Jose, CA 95134 USA March 2013 202-11206-02 v1.0 Support Thank you for selecting NETGEAR products.

More information

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1

SAS to SAS/SATA JBOD Subsystem. User Manual. Revision 1.1 SAS to SAS/SATA JBOD Subsystem Revision 1.1 Table of Contents Chapter 1 Introduction... 3 1.1 Features... 4 1.2 Technical Specifications... 5 1.3 Unpacking the JBOD Expansion Chassis... 6 1.4 Identifying

More information

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 6 Supporting Hard Drives

A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e. Chapter 6 Supporting Hard Drives A+ Guide to Hardware: Managing, Maintaining, and Troubleshooting, 5e Chapter 6 Supporting Hard Drives Objectives Learn about the technologies used inside a hard drive and how data is organized on the drive

More information

RocketU 1144CM Host Controller

RocketU 1144CM Host Controller RocketU 1144CM Host Controller 4-Port USB 3.0 PCI-Express 2.0 x4 RAID HBA for Mac User s Guide Revision: 1.0 Dec. 13, 2012 HighPoint Technologies, Inc. 1 Copyright Copyright 2013 HighPoint Technologies,

More information

Dell PowerEdge RAID Controller (PERC) S130 User s Guide

Dell PowerEdge RAID Controller (PERC) S130 User s Guide Dell PowerEdge RAID Controller (PERC) S130 User s Guide Notes, Cautions, and Warnings NOTE: A NOTE indicates important information that helps you make better use of your computer. CAUTION: A CAUTION indicates

More information

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2

Taurus Super-S LCM. Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives. User Manual July 27, v1.2 Dual-Bay RAID Storage Enclosure for two 3.5 Serial ATA Hard Drives User Manual July 27, 2009 - v1.2 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III

More information

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide

ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide ServeRAID M5015 and M5014 SAS/SATA Controllers Product Guide The ServeRAID M5015 and ServeRAID M5014 SAS/SATA Controllers for System x are the next-generation 6 Gbps SAS 2.0 RAID controllers. The adapters

More information

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide. support.dell.com

Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5. User s Guide.   support.dell.com Dell OpenManage Connection for Tivoli Enterprise Console Version 3.5 User s Guide www.dell.com support.dell.com Notes and Notices NOTE: A NOTE indicates important information that helps you make better

More information

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0

MD4 esata. 4-Bay Rack Mount Chassis. User Manual February 6, v1.0 4-Bay Rack Mount Chassis User Manual February 6, 2009 - v1.0 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM esata equipped

More information

MNAS-4100 User s Guide. Preliminary draft only

MNAS-4100 User s Guide. Preliminary draft only MNAS-4100 User s Guide Preliminary draft only April 2006 TRADEMARKS All brand and product names are trademarks or registered trademarks of their respective companies. NOTE The information in this manual

More information

P3AM ENZ0. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems. Operation Guide (Basic)

P3AM ENZ0. FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems. Operation Guide (Basic) FUJITSU Storage ETERNUS DX100 S4/DX200 S4, ETERNUS DX100 S3/DX200 S3 Hybrid Storage Systems Operation Guide (Basic) This page is intentionally left blank. Preface Fujitsu would like to thank you for purchasing

More information

Contact DDN Technical Support for assistance if you need to update SEP firmware version or earlier on the SS8460.

Contact DDN Technical Support for assistance if you need to update SEP firmware version or earlier on the SS8460. SEP firmware version 0120-145 is a MANDATORY UPGRADE for all SS8460 enclosures. The firmware addresses an issue with resonance or vibration that can cause rotating disk drives to persistently fail or go

More information

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018

White Paper. EonStor GS Family Best Practices Guide. Version: 1.1 Updated: Apr., 2018 EonStor GS Family Best Practices Guide White Paper Version: 1.1 Updated: Apr., 2018 Abstract: This guide provides recommendations of best practices for installation and configuration to meet customer performance

More information

AMD RAID Installation Guide

AMD RAID Installation Guide AMD RAID Installation Guide 1. AMD BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows 7 / 7 64-bit / Vista TM / Vista TM 64-bit /

More information

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, v1.2

Hydra Super-S LCM. 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, v1.2 4-Bay RAID Storage Enclosure (3.5 SATA HDD) User Manual July 30, 2009 - v1.2 EN Introduction 1 Introduction 1.1 System Requirements 1.1.1 PC Requirements Minimum Intel Pentium III CPU 500MHz, 128MB RAM

More information

User s guide for T5_R5 esuf

User s guide for T5_R5 esuf User s guide for T5_R5 esuf Overview Introduction T5_R5-ESUF is One to Five SATA Port Multiplier hardware RAID Controller with LCD Module. It is designed to provide USB2.0/FireWire400/800 and esata ports

More information

RocketRAID 3600 Series

RocketRAID 3600 Series RocketRAID 3600 Series SATA 6Gb/s PCI-Express 2.0 x 8 RAID HBA User s Guide Revision: 1.01 Jun. 23, 2015 HighPoint Technologies, Inc. 1 Copyright Copyright 2013 HighPoint Technologies, Inc. This document

More information

Scale-Out Functionality User Guide (rev. v3 FW v and after) Important Notes:

Scale-Out Functionality User Guide (rev. v3 FW v and after) Important Notes: Scale-Out Functionality User Guide (rev. v3 FW v3.02.00 and after) Important Notes: 1. The Client mode is the default mode. 2. The Scale-Out function can be setup as Client-Server combo mode or Pure Server

More information

Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual

Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual Dell PowerVault MD3800i and MD3820i Storage Arrays Owner's Manual Regulatory Model: E03J and E04J Series Regulatory Type: E03J001 and E04J001 Notes, cautions, and warnings NOTE: A NOTE indicates important

More information

MSA Event Descriptions Reference Guide

MSA Event Descriptions Reference Guide MSA Event Descriptions Reference Guide Abstract This guide is for reference by storage administrators to help troubleshoot storage-system issues. It describes event messages that may be reported during

More information

Universal RAID Utility (VMware Version) User's Guide. 1st Edition February A

Universal RAID Utility (VMware Version) User's Guide. 1st Edition February A Universal RAID Utility (VMware Version) User's Guide 1st Edition February 2009 808-882328-750-A Trademarks NEC ESMPRO and NEC EXPRESSBUILDER are trademarks of NEC Corporation. VMware is a registered trademark

More information

NVIDIA RAID Installation Guide

NVIDIA RAID Installation Guide NVIDIA RAID Installation Guide 1. NVIDIA BIOS RAID Installation Guide.. 2 1.1 Introduction to RAID.. 2 1.2 RAID Configurations Precautions 3 1.3 Installing Windows XP / XP 64-bit / Vista / Vista 64-bit

More information

This page is intentionally left blank.

This page is intentionally left blank. This page is intentionally left blank. Preface This ETERNUS Multipath Driver User's Guide describes the features, functions, and operation of the "ETERNUS Multipath Driver" (hereafter referred to as "Multipath

More information

Chapter 2 Using WebBIOS This chapter explains the WebBIOS setup procedures. WebBIOS is a basic utility to set up and manage the array controller.

Chapter 2 Using WebBIOS This chapter explains the WebBIOS setup procedures. WebBIOS is a basic utility to set up and manage the array controller. MegaRAID SAS User s Guide Areas Covered Before Reading This Manual This section explains the notes for your safety and conventions used in this manual. Chapter 1 Overview This chapter provides an overview

More information

XP7 High Availability User Guide

XP7 High Availability User Guide XP7 High Availability User Guide Abstract HPE XP7 High Availability helps you create and maintain a synchronous copy of critical data in a remote location. This document describes and provides instructions

More information

Replication is the process of creating an

Replication is the process of creating an Chapter 13 Local tion tion is the process of creating an exact copy of data. Creating one or more replicas of the production data is one of the ways to provide Business Continuity (BC). These replicas

More information

Storage Profiles. Storage Profiles. Storage Profiles, page 12

Storage Profiles. Storage Profiles. Storage Profiles, page 12 , page 1 Disk Groups and Disk Group Configuration Policies, page 2 RAID Levels, page 6 Automatic Disk Selection, page 7 Supported LUN Modifications, page 8 Unsupported LUN Modifications, page 8 Disk Insertion

More information

FASTTRAK TX4000 QUICK START GUIDE. Version 1.2

FASTTRAK TX4000 QUICK START GUIDE. Version 1.2 FASTTRAK TX4000 QUICK START GUIDE Version 1.2 FastTrak TX4000 Copyright 2002 Promise Technology, Inc. Copyright by Promise Technology, Inc. (Promise Technology). No part of this manual may be reproduced

More information

HMC ENHANCED GUI QUICK START GUIDE 1.0 Classic GUI to Enhanced GUI Mappings and Enhanced GUI Improvements

HMC ENHANCED GUI QUICK START GUIDE 1.0 Classic GUI to Enhanced GUI Mappings and Enhanced GUI Improvements HMC ENHANCED GUI QUICK START GUIDE 1.0 Classic GUI to Enhanced GUI Mappings and Enhanced GUI Improvements August 2017 Table of Contents Contributing Author: Karyn Corneli Co-Author: Jacobo Vargas Introduction...

More information

Understanding printer messages

Understanding printer messages The operator panel displays messages describing the current state of the printer and indicates possible printer problems you must resolve. This topic provides a list of all printer messages, explains what

More information

SOHOTANK ST4-TB User Manual

SOHOTANK ST4-TB User Manual SOHOTANK ST4-TB User Manual Introduction SOHOTANK ST4-TB User Manual Thank you for purchasing STARDOM products. This manual will introduce the ST4 Series. Before using your ST4, please read this manual

More information

This option lets you reset the password that you use to log in if you do not remember it. To change the password,

This option lets you reset the password that you use to log in if you do not remember it. To change the password, User s Guide Overview IDrive offers the most cost effective BMR functionality with onsite disk image backup for SMBs. Store entire data of hard disks including the operating system (OS) and application

More information

SAP Engineering Control Center Interface to Inventor - User Manual

SAP Engineering Control Center Interface to Inventor - User Manual User Manual Management of CAD data and documents in SAP SAP Engineering Control Center Interface to Inventor SAP Engineering Control Center Interface to Inventor manages design data in SAP. Given by the

More information

Chapter 2 CommVault Data Management Concepts

Chapter 2 CommVault Data Management Concepts Chapter 2 CommVault Data Management Concepts 10 - CommVault Data Management Concepts The Simpana product suite offers a wide range of features and options to provide great flexibility in configuring and

More information

Drobo 5N2 User Guide

Drobo 5N2 User Guide Drobo 5N2 User Guide Contents 1 Drobo 5N2 User Guide... 6 1.1 Before You Begin... 7 1.1.1 Product Features at a Glance... 8 1.1.2 Checking Box Contents...10 1.1.3 Checking System Requirements...11 1.1.3.1

More information

Getting Started. HP Business PCs

Getting Started. HP Business PCs Getting Started HP Business PCs Copyright 2010, 2012-2014, 2016 HP Development Company, L.P. Windows is a registered trademark or trademark of Microsoft Corporation in the United States and/or other countries.

More information