Connection box ECblue (LON)

Size: px
Start display at page:

Download "Connection box ECblue (LON)"

Transcription

1 Connection box ECblue (LON) english Connection control fan MICRO-FIT Operating Instructions

2 General notes 1 General notes 1.1 Meaning These description is valid only in combination with operating instructions of the used devices. The remarks concerning safety, installation and connection described in those operating instructions must be followed! Before installation and start-up, read this documentation carefully to ensure correct use! 2 Safety instructions Mounting, electrical connection, and start-up operation may only be carried out by an electrical specialist in accordance with electrotechnical regulations (e.g. DIN EN or DIN EN 60204)! It is strictly forbidden for work to be carried out on any components while they are connected to live voltage. The open equipment is protected to IP00. It is possible to come into direct contact with dangerous voltages! 3 General description 3.1 Application This connection box can only be used in conjunction with ZIEHL-ABEGG ECblue fans with motor size B (IP20). 3.2 Function ECblue fans combined with the ECblue (LON) connection box provide the following functions: The connection box can be used to communicate with the fan controller. ECblue fans can be integrated into existing LON networks. A LON network of several ECblue fans can be built up. The communication between the fans happens via LONWORKS TP/FT Transport The device is packed ex factory to suit the transport method previously agreed. Always use the original packaging materials when transporting the device. Avoid shocks and impacts to the device during the transport. During manual handling the human lifting and carrying restrictions must be observed and adhered to. 3.4 Storage The device must be stored in its original packaging in a dry and weather-proof room. Avoid exposure to extreme heat and cold. Avoid over-long storage periods (we recommend a maximum of one year). 3.5 Disposal / recycling Disposal must be carried out professionally and in an environmentally friendly way in accordance with the respective national legal stipulations. " Separate the materials by type and in an environmentally friendly way. " If necessary, commission a specialist company with the waste disposal. 2/10

3 Mounting 4 Mounting Proceed as follows: " Create the installation cut-out and fastening hole as shown in the drawing. " Insert the device into the installation cut-out from the front and secure with a screw. Dimensions [mm] 3/10

4 Electrical installation 5 Electrical installation 5.1 Safety precautions Danger due to electric current Work on electric components may only be carried out by trained electricians or by persons instructed in electricity under the supervision of an electrician in accordance with electrical engineering regulations. It is forbidden to carry out work on electrically live parts. 5.2 Connection components Front view Back 1 Fan control connection (MICRO-FIT, max. connection cross-section: 0.14 mm 2 / AWG26). The LEDs on the connection box are supplied from the connected fan (output voltage +10 V). 2 Connection line fan (tension clamp connection mm 2 flexible with wire end ferrule) 3 Line input connection box (Wieland plug series GST 18i3, suitable socket part e.g. GST 18i3 S B1 Z R1 or GST 18i3 1 F B2 Z R1) 4 LED green = Operation / Flashing error code (see ECblue assembly instructions, chapter Operating state display ) 5 LED red = Fault (see ECblue assembly instructions, chapter operating state display ) 6 BUS1 (RJ45) 7 Service (RJ45) 8 BUS2 (RJ45) 9 HALL sensor for "service pin". To trigger the "service pin", position the bar magnet (item no ) in the left corner. Information " As an option, the service pin can be triggered with a 5 V pulse (typical duration 0.5 s) at V+ and V-. " The fan must be set to the address of 247, otherwise no communication! 4/10

5 Electrical installation 5.3 BUS1, BUS2 and Service pin assignment 1. Net A 2. Net B 3. not connected 4. not connected 5. not connected 6. not connected 7. GND (V-) 8. ID +5V (V+) PIN 1 on BUS1, BUS2 and Service are through connected (NET bus connection A for fan). PIN 2 on BUS1, BUS2 and Service are through connected (NET B bus connection for fan). PIN 3 and PIN 6 are not connected. PIN 4 on BUS1, BUS2 and Service are only through connected to one another. PIN 5 on BUS1, BUS2 and Service are only through connected to one another. PIN 7 on BUS1, BUS2 and Service are through connected to one another. NET_A NET_B V- V+ NET_A NET_B V- V+ NET_A NET_B V- V+ X1-a 1 X1-b 2 X1-c 3 X1-d 4 X1-e 5 X1-f 6 X1-g 7 X1-h 8 X2-a 1 X2-b 2 X2-c 3 X2-d 4 X2-e 5 X2-f 6 X2-g 7 X2-h 8 X3-a 1 X3-b 2 X3-c 3 X3-d 4 X3-e 5 X3-f 6 X3-g 7 X3-h 8 NET_A NET_B ID (+5V) ID (+5V) GND ID (+5V) BUS1 Service BUS2 MOBS05A_extract /10

6 Electrical installation 5.4 Communication Bus connection The connection is made using the RJ45 sockets, Bus 1 and Bus 2. A minimum of CAT5 (STP) are recommended as the cables. The cable shield is connected to PE by an RC element inside the connection box. As well as a Service PIN message at the LON node being triggered by a magnet (see Connection components chapter), it can alternatively be triggered at any time by applying a brief 5 V (+- 10%, typical 5 ma) voltage pulse of typically 0.5 s at PIN 7 (GND) and PIN 8 (+5V). Using the Service connection,m this can also be done with the bus wiring connected to BUS1 and BUS2. Information The wiring connected to the connection box is always based on the bus topology. With the recommended CAT5 patch cable, the maximum cable length is 500 m. ( Wiring and terminator in the LON network) Wiring and terminating resistor in the LON network With bus wiring, a terminating resistor of 100 Ω / 0.25 W must be fitted to the beinning and end of the line. Information The stub lines to the individual devices should be kept as short as possible (max. 5 m). Example: bus wiring 100 ohm 100 ohm 100 ohm = terminating resistor v_busverdr_lon.vsd Information If any matters are unclear, you can send for our technical information sheet "Network structure of a LON " - TIL00_35. It contains information about the topology, circuitry and selection of types of cable. 6/10

7 Electrical installation Network variable interface for ECblue connection box This network variable interface enables the user to monitor the motor controller and change the speed of the controlled fan. The interface primarily represents a speed sensor (nvospeed), as this function is the focus when operating the fan. The interface also uses nvoalarm to provide the device status for the network. The device uses nvopowerout to provide the current fan level of the power component. The speed and fan level can theoretically be used to determine the degree of filter contamination. The controller can be used to move to three fixed (static) operating points. The values of the operating points determine ncispeed1, ncispeed2 and ncispeed3. The setting is made in percent, with % corresponding to a speed between 0 ncimaxspeed. The choice of one of the two operating points is made using nvispeedselect or, if the internal timer clock (nciautonight) is activated, based on the time settings using ncinightsrt and ncinightend. If using nvispeedselect, note that the value of this variable is volatile, i.e. after a device reset the variable takes on the value 0 (day). To ensure that night operation is maintained, the variable should be updated cyclically. You can use ncienable to enable the motor controller function. The variables nvovisual, nvoparameter and nviparameter are available for use with ZIEHL-ABEGG software and installation devices. For dynamic operation, i.e. operation in which the speed changes very often (e.g. control applications), a different operating mode has to be selected as the static rotational speed specifications ncispeedx only allow a limited number of write accesses (max. 10,000 over the service life of the device). You can use Nv ncioperationmode to activate dynamic operation. The rotational speed specification can be expressed as a percentage (as for ncispeedx) using nvispeedrel or by specifying an absolute speed using nvispeedabs. Both specifications are limited by nciminspeed and ncimaxspeed. For a device reset, in dynamic operation the value of the static operating point ncispeed1 is copied to the dynamic input variables. This guarantees starting with no delay, a kind of emergency speed. The minimum and maximum time between the send actions for a network variable (nvo) can be set using nciminsendtime and ncimaxsendtime. Objekt Type #0 Node Inputs/outputs Type SNVT Value range Default Description nvirequest nvostatus SNVT_obj_request (92) SNVT_obj_- status (93) All bits are 0 Input, which can be used to initiate status messages for the node. Generated when updating nvirequest. 7/10

8 Electrical installation Objekt Type #1 Open Loop Sensor Inputs/outputs Type Value range Default Description nvospeed nvoalarm SNVT_rpm (102) SNVT_alarm_2 (164) , 0xFFFF nvoerror* uint (1 Byte) 128, 0 invalid nvorelais nvispeedselect ncienable ncimaxspeed nciminspeed ncispeed1 ncispeed2 nciautonight nvitime ncinightsrt ncinightend SNVT_switch (95) disc (22) disc (22) SNVT_rpm (102) SNVT_rpm (102) cont (55) cont (55) disc (22) SNVT_time_stamp (84) SNVT_time_stamp (84) SNVT_time_stamp (84).value ,.state 0,1 X X X X X Measured absolute speed Option 128 no fault > 128 fault code table Fault output. In case of fault.state = 1 and.value x 2 = Fault code ST_OFF (0): ncispeed1 ST_LOW (1): ncispeed2 ST_MED (2): ncispeed3 ST_ON, ST_OFF , 0xFFFF , 0xFFFF.value ,.value , ST_ON, ST_OFF ST_OFF Fan blocked ST_ON Fan enabled 1100 Maximal Speed 0 Minimal Speed 0 Operating point 1 (day) 0 Operating point 2 (night) ST_OFF Internal interval timer blocked ST_ON Internal interval timer operational System time nvoconttemp** uint (1 Byte) 0.. X Option nvopowerout SNVT_switch (95).value ,.state 0,1 Night operation start time Night operation end time X Power requirement (in %) nvovisual*** struct_visual Summary of important nvo for faster queries nvopararesp*** viparareq*** ncispeed3 SNVT_preset (94) SNVT_preset (94) cont (55) ncioperationmode disc (22) nvispeedrel nvispeedabs cont (55) SNVT_rpm (102).value , To allow easier / extended configuration with ZIEHL- ABEGG software and installation devices 0 Operating point 3 (holiday) ST_OFF (0): Static operation with ncispeedx ST_LOW (1): Dynamic operation with nvispeedrel ST_MED (2): Dynamic operation with nvispeedabs.value , , 0xFFFF ncispeed1 ncispeed1 abs. Dynamic rotational speed specification, relative Dynamic rotational speed specification, absolute 8/10

9 Enclosure nciminsendtime ncimaxsendtime nviaddrrelais SNVT_time_- sec (107) SNVT_time_- sec (107) SNVT_switch (95) , 0,1sec , 0,1sec.value ,.state 0,1 2,0 sec Minimum time between send actions 60,0 sec Maximum time between send actions for Nv (if no send action occurs within this time, one is generated) 0 0 For internal ZIEHL-ABEGG use only! Required for MODBUS AUTO addressing. * Use nvoalarm or nvorelay for preference ** Not used, only for testing purposes/diagnostics *** For internal ZIEHL-ABEGG use only Alarm codes (nvoalarm, nvorelay) error code Error description Reaction 128 no error 129 general error No specific description 131 motor over temperature (thermostats) Motor shuts down. After cooling, switching back on is possible by enabling again or re-applying the mains voltage. 132 Motor blocked Motor shuts down. Starting retried after approx. 1 minute. 134 Earth fault Motor shuts down. Switching back on is only possible by re-applying the mains voltage. 135 Hall sensor error Starting retried after approx. 1 minute. 136 Overcurrent fault Motor shuts down. Starting retried after approx. 1 minute. 150 external communication error Motor continues running with last set values 158 Supply voltage too high (overvoltage) Motor shuts down. Starting retried if undervoltage no longer exists within 75 s. Otherwise fault message. 6 Enclosure 6.1 Technical data Type Part-No Voltage supply Transceiver Communication Connection box - ECblue Electromagnetic compatibility Connection box ECblue (LON) 10 V DC, I max 30 ma, from ECblue motor size B (IP20) TP/FT10 RS485 Permissible ambient temperature C Permissible temperature range for storage and transport Housing protection Weight Interference emission EN (domestic household applications) Interference immunity EN (industrial applications) C IP20 (in installed condition) 0.16 holder plate 9/10

10 Enclosure 6.2 Manufacturer reference Our products are manufactured in accordance with the relevant international regulations. If you have any questions concerning the use of our products or plan special uses, please contact: ZIEHL-ABEGG SE Heinz-Ziehl-Straße Künzelsau Telephone: +49 (0) Telefax: +49 (0) Service information If you have any technical questions while commissioning or regarding malfunctions, please contact our technical support for control systems - ventilation technology. phone: +49 (0) fan-controls-service@ziehl-abegg.de Our worldwide contacts are available in our subsidiaries for deliveries outside of Germany, see If you make returns for inspections or repairs we need certain information in order to facilitate focused trouble shooting and fast repair. Please use our repair ticket for this. It is provided to you after you have consulted our support department. In addition, you can download it from our homepage. Support - Downloads - General documents. 10/10

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002

english S-5EC Potentiometer 5-step Operating Instructions Keep for reference! L-BAL-E265-GB 1608 Index 002 S-5EC english Potentiometer 5-step Operating Instructions Keep for reference! Content 1 General notes............................................ 3 1.1 Structure of the operating instructions....................

More information

Communication module for ZIEHL-ABEGG ECblue fans and frequency inverters of the Basic series

Communication module for ZIEHL-ABEGG ECblue fans and frequency inverters of the Basic series AM-PROFINET english 349072 Communication module for ZIEHL-ABEGG ECblue fans and frequency inverters of the Basic series Operating Instructions Attention, electrostatically sensitive components! See chapter

More information

AM-PROFIBUS. Part.-No Operating Instructions. Attention, electrostatically sensitive components! See chapter 4 "Mounting the Module" english

AM-PROFIBUS. Part.-No Operating Instructions. Attention, electrostatically sensitive components! See chapter 4 Mounting the Module english AM-PROFIBUS english Part.-No. 349063 Communication module for ZIEHL-ABEGG ECblue fans and frequency inverters of the Basic series Operating Instructions Attention, electrostatically sensitive components!

More information

ECblue highefficiency

ECblue highefficiency Movement by Perfection The Royal League in ventilation, control and drive technology ECblue highefficiency motors The complete range for axial and centrifugal fans Choose efficiency: The innovative range

More information

SK CU4-ECT-C Part number:

SK CU4-ECT-C Part number: SK CU4-ECT-C Part number: 275 271 517 EtherCAT Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

Operating Instructions VEGAMET 381

Operating Instructions VEGAMET 381 Operating Instructions VEGAMET 381 in out Contents Contents 1 About this document... 4 1.1 Function... 4 1.2 Target group... 4 1.3 Symbolism used... 4 2 For your safety... 6 2.1 Authorised personnel...

More information

SK CU4-EIP-C Part number:

SK CU4-EIP-C Part number: SK CU4-EIP-C Part number: 275 271 519 EtherNet/IP Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

LONWORKS Power Line Communication Adapter

LONWORKS Power Line Communication Adapter ABB AB P.O. Box 1005 SE-611 29 NYKÖPING Sweden Tel: +46-155 295000 Fax: +46-155 288110 LONWORKS Power Line Communication Adapter CAL 06000/CCL 06000 User s Manual Rev A Page 1 of 15 Table of Contents 1

More information

English. Operating manual. Universal transmitter UT125. Save for later reference. Companies / brands of GHM

English. Operating manual. Universal transmitter UT125.  Save for later reference. Companies / brands of GHM English Operating manual Universal transmitter UT125 Companies / brands of GHM www.ghm-messtechnik.de Save for later reference. Table of contents page 1. Intended use (areas of application)... 3 1.1 Safety

More information

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions

MVS RAIL ELECTRONIC FAN SPEED CONTROLLER. Mounting and operating instructions DIN RAIL ELECTRONIC FAN SPEED Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 WIRING

More information

RTD-W Installation Instructions

RTD-W Installation Instructions RTD-W Installation Instructions 0V +V POWER 15-24VDC 0V S1 S2 S3 0V S4 S5 S6 English RTD-W Installation Instructions 100.00 RTD-W Control Interface realtime Control Systems 24VAC/30VDC, 1A REMC P1 P2 RS485

More information

NEUROLOGIC RESEARCH CORPORATION MODEL 2150

NEUROLOGIC RESEARCH CORPORATION MODEL 2150 NEUROLOGIC RESEARCH CORPORATION FOUR DIGITAL INPUT / FOUR DIGITAL OUTPUT NETWORK NODE - Very compact design available in DIN Rail and NEMA 4X enclosures. - LonWorks FTT-10A network interface with all inputs

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -...

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 120 W -... T-Logg 120 K -... E39.0.1X.6C-01 Data logger for standard signals as of version 1.0 Operating Instruction T-Logg 120... T-Logg 120 W -... T-Logg 120 K -... GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße

More information

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS

MAKING MODERN LIVING POSSIBLE AK-255 CO 2. Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS MAKING MODERN LIVING POSSIBLE Controller On-Site Installation Guide DANFOSS ELECTRONIC CONTROLS & SENSORS How to Use This Guide Read this Guide completely as you install and start up your new Controller.

More information

Resistance measuring module

Resistance measuring module s 8 176 8176P01 TX-I/O Resistance measuring module TXM1.8P 8 inputs with LED signal / fault display. 8 resistance measuring inputs with individual configuration of resistance or temperature measurement.

More information

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center.

Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or service center. Liebert PSA iton User Manual Version: V2.8 Revision date: November 14, 2005 Emerson Network Power provides customers with technical support. Users may contact the nearest Emerson local sales office or

More information

Operating Manual. English. Digital-Analog Converter DACON8-UMB.

Operating Manual. English. Digital-Analog Converter DACON8-UMB. English Digital-Analog Converter www.lufft.de G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany. We reserve the right to amend technical specifications at any time. Contents 1 Please Read Before

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet LR24A-MOD Communicative rotary actuator for ball valves orque motor 5 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion of sensor signals Communication via BACnet

More information

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016

Operating instructions AS-i SmartLine module AC3200 AC /00 06/2016 Operating instructions AS-i SmartLine module AC3200 AC3201 80237876/00 06/2016 Contents 1 Preliminary note...3 1.1 Symbols used...3 1.2 Warnings used...3 2 Safety instructions...3 2.1 General...3 2.2 Target

More information

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC

Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC Data sheet GCM MOD GMM EC.1 Communications module Modbus for GMM EC ERP no.: 5206415 GCM MOD GMM EC.1 www.guentner.de Page 2 / 15 Contents 1 GCM MOD GMM EC.1...3 1.1 Functional description...3 1.2 Connections...

More information

DPC200 Part.-No

DPC200 Part.-No english DPC200 484048 Sensor-control module for differential pressure and volume Operating Instructions Software version: D1673A from Version 1.03 Content 1 General notes.........................................

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 H20.0.34.6C-05 EASYBus-Sensor module for temperature from version V3.2 Operating Manual EBT 2R Content 1 INTENDED USE 2 2 GENERAL ADVICE 2 3 SAFETY INSTRUCTIONS 2 4 DISPOSAL NOTES 2 5 ASSIGNMENT 3 6 DIMENSION

More information

MODEL 2000T Initial Draft

MODEL 2000T Initial Draft TEMPERATURE DISPLAY AND COMMAND MODULE On-board temperature sensor. Mounts on any standard single-gang wiring conduit box. Compact, thin and stylish design. Only 2.8 W x 4.55 H x 0.79 D Sensing element

More information

Operating instructions Evaluation system for flow sensors VS / / 2013

Operating instructions Evaluation system for flow sensors VS / / 2013 Operating instructions Evaluation system for flow sensors VS3000 7097 / 0 07 / 203 Contents Preliminary note...2 2 Safety instructions...3 3 Function and features... Mounting.... Mounting of the sensors...

More information

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO

Operating Manual UMB ISO Converter ISOCON Order Number: 8160.UISO Order Number: 8160.UISO Status: V3; 17.09.2010c G. Lufft Mess- und Regeltechnik GmbH, Fellbach, Germany 1 TABLE OF CONTENTS PLEASE READ BEFORE USE... 3 DESCRIPTION... 5 UMB ISO CONVERTER ISOCON... 6 CONFIGURATION...

More information

LX Series Remote Input/Output (I/O) Controller

LX Series Remote Input/Output (I/O) Controller LX Series Remote Input/Output (I/O) Controller Product Bulletin LX-IO520-1, LX-IO401-1, LX-IO301-1 Code No. LIT-12011491 Issued June 22, 2009 The LX Series Remote Input/Output (I/O) controller extends

More information

Manual Release 09/2002. cm-lon FOR LOGO! Communication with LOGO! with LON systems

Manual Release 09/2002. cm-lon FOR LOGO! Communication with LOGO! with LON systems Manual Release 09/2002 cm-lon FOR LOGO! Communication with LOGO! with LON systems s LOGO! Expansion Module Manual Chapters Safety Notices 1 Getting to know 2 Mounting and wiring the 3 Putting the into

More information

Display Panel BAT 100 LSN. en Operation Guide

Display Panel BAT 100 LSN. en Operation Guide Display Panel BAT 100 LSN en Operation Guide Display Panel Table of Contents en 3 Table of contents 1 Safety 4 2 Short information 4 3 System overview 5 4 Installation 6 5 Connection 11 6 Maintenance

More information

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket

LM24A-MOD. Cable 1 m, 6 x 0.75 mm 2 RJ12 socket echnical data sheet Damper actuator for Modbus for adjusting air dampers in ventilation and air conditioning systems in buildings orque 5 Nm Nominal voltage AC/DC 4V Communication via Modbus RU (RS-485)

More information

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication

RXB10.1. Room controller. Siemens Building Technologies Building Automation DESIGO RXB. for chilled ceilings and radiators with EIB bus communication 3 870 DESIO RXB Room controller for chilled ceilings and radiators with EIB bus communication RXB10.1 The RXB10.1 controller is used for temperature control in individual rooms: For chilled ceilings and

More information

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions

HPS-M -2 DIFFERENTIAL PRESSURE TRANSMITTER. Mounting and operating instructions DIFFERENTIAL PRESSURE Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 5 OPERATIONAL

More information

Operating instructions. Speed monitor D / / 2014

Operating instructions. Speed monitor D / / 2014 Operating instructions Speed monitor D200 80005257 / 00 05 / 2014 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5 2.2 Target group...5

More information

SK CU4-PNT-C Part number:

SK CU4-PNT-C Part number: SK CU4-PNT-C Part number: 275 271 515 PROFINET IO Internal Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

Operating instructions. Standstill monitor A / / 2011

Operating instructions. Standstill monitor A / / 2011 Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II

More information

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide

Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541 PoE Model: KSD-541-P. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-P Installation Guide DOC.080104-1- (C) 2008 KTI Networks Inc. All rights reserved.

More information

MU110-6U. Analog output module 6 channel. User guide

MU110-6U. Analog output module 6 channel. User guide MU110-6U Analog output module 6 channel User guide MU110-6U_2016.12_0221_EN All rights reserved Subject to technical changes and misprints akytec GmbH Vahrenwalder Str. 269 A 30179 Hannover Тел.: +49 (0)

More information

TAC Xenta 121-HP Programmable Heat Pump Application

TAC Xenta 121-HP Programmable Heat Pump Application TAC Vista TAC Xenta 121-HP Programmable Heat Pump Application TAC Xenta 121-HP is an easily programmable controller intended for heat pumps, with or without re-heat. It can be configured for use with 1,

More information

Operating instructions RFID evaluation unit DTE / / 2016

Operating instructions RFID evaluation unit DTE / / 2016 Operating instructions RFID evaluation unit DTE101 80005398 / 01 06 / 2016 Contents 1 Preliminary note...4 1.1 Notes on this document...4 1.2 Symbols used...4 2 Safety instructions...4 2.1 General...4

More information

DSE2548 DSENET OUTPUT EXPANSION MODULE. DSEGenset DSE2548 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS

DSE2548 DSENET OUTPUT EXPANSION MODULE. DSEGenset DSE2548 COMPREHENSIVE FEATURE LIST TO SUIT A WIDE VARIETY OF GEN-SET APPLICATIONS DSEGenset DSE2548 DSENET OUTPUT EXPANSION MODULE ENVIRONMENTAL TESTING STANDARDS ELECTRO-MAGNETIC COMPATIBILITY BS EN 61000-6-2 EMC Generic Immunity Standard for the Industrial Environment BS EN 61000-6-4

More information

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel

Manual# Installation Manual. 200E Series. DCU 210E/208E Engine Panel RP 210E/220E Remote Panel Manual# 1006495 Installation Manual 200E Series DCU 210E/208E Engine Panel RP 210E/220E Remote Panel Installation Manual for the Marine Pro 200E Series ~~~ DCU 210E/208E Diesel Engine Control Unit RP 210E/220E

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 641 DESIGO RX Room unit with PPS2 interface for use with: QAX321 devices of the ranges DESIGO RXC, RXB, and RXA (PPS2) DESIGO PX Automation stations 1) devices with a PPS2 interface Room temperature

More information

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L

OHIO SEMITRONICS, INC. AC MULTIFUNCTION PROGRAMMABLE TRANSDUCERS & -1000L AC PROGRAMMABLE TRANSDUCERS MODBUS OR LONWORKS DESCRIPTION The DMT-1000 is a programmable transducer with an RS-485 bus interface (MODBUS ). It supervises several variables of a poly-phase electrical power

More information

Supplementary operating instructions for your air curtain system Controller TMC 500

Supplementary operating instructions for your air curtain system Controller TMC 500 Supplementary operating instructions for your air curtain system Controller TMC 500 (Translation of the original) Serial number: Year: Please quote this number when contacting customer service! Date 08.04.2016

More information

English. Operating manual. Limit switch GS125. Keep for future reference. Ventures / brands of GHM

English. Operating manual. Limit switch GS125.  Keep for future reference. Ventures / brands of GHM English Operating manual Limit switch GS125 Ventures / brands of GHM www.ghm-messtechnik.de Keep for future reference. Table of contents Page 1. Intended use (areas of application)... 3 1.1 Safety signs

More information

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications

DESIGO RX Individual room controllers. for fan-coil systems, chilled ceilings and radiators, with LONMARK-compatible bus communications 3 834 DESIO RX Individual room controllers for fan-coil systems, chilled ceilings and radiators, with MARK-compatible bus communications RXC20.1 RXC21.1 The RXC20.1 and RXC21.1 controllers are used for

More information

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26

GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26 E39.0.31.6C-02 Data logger for humidity temperature as of version V1.0 Operating Manual T-Logg 160 GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0 +49 (0) 9402

More information

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions

STR-3 STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER. Mounting and operating instructions STANDARD 3-PHASE 230 VAC TRANSFORMER CONTROLLER Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA

More information

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x

Operating Instructions (Translation) 3. Safety Information. 1. Description. 2. Explosion Protection. Supply module Type 17-21BB-170x 1. Description The supply module was developed specially for direct mounting in hazardous areas in Zone 1 and 21 and is ATEX-certified. The supply module is a permanently installed piece of electrical

More information

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions

DSTHM-2 COMBINED T AND RH DUCT TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAMS 5 WIRING AND

More information

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02

NMID. Remote control. SAPIM I/O number. SAPIM I/O number NBRN (RS485) ZM100. Relay, 24 VDC - + UO07 UI11 UI10 UI09 UI08 UI07 UI06 UI05 UI04 UI03 UI02 1/8 NRK16/A, NRK16-B/A, (NRK16-T /A, NRK14-T /A, NRK16-WEB/A) Control and interlock devices with pre-programmed system-specific application modules The controllers may be used as stand-alone control and

More information

MINI MCR-SL-MUX-V8-FLK 16

MINI MCR-SL-MUX-V8-FLK 16 Multiplexer Data sheet 445_en_4 PHOENIX CONTACT 22-5-2 Description The MINI Analog multiplexer can be used to generate one analog output from up to eight input signals. During cyclical execution, 8, 6,

More information

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version

Part No. Description Product Life Cycle Phase *) unit, 24 VDC, spring terminals. unit, 24 VDC, spring terminals, XC version Ordering Data DATA SHEET TU520 Terminal Unit 1 Ordering Data Part No. Description Product Life Cycle Phase *) 1SAP 214 400 R0001 1SAP 414 400 R0001 TU520-ETH, PROFINET I/O terminal unit, 24 VDC, spring

More information

CMC III Universal Sensor

CMC III Universal Sensor CMC III Universal Sensor DK 7030.190 Assembly and operating instructions Foreword Foreword Dear Customer, Thank you for choosing our CMC III universal sensor (referred to hereafter as "universal sensor")!

More information

EY-RU 355: Room operating unit, ecounit355

EY-RU 355: Room operating unit, ecounit355 Product data sheet 1.1 94.041 EY-RU 355: Room operating unit, ecounit355 How energy efficiency is improved Individual setting of occupancy and absence as well as room setpoint correction, control of lights

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

Mounting and Operating Instructions EB EN. Electric Actuators with LON Interface. Type 5824 without Type 5825 with fail-safe action

Mounting and Operating Instructions EB EN. Electric Actuators with LON Interface. Type 5824 without Type 5825 with fail-safe action Electric Actuators with LON Interface Type 5824 without Type 5825 with fail-safe action Fig. 1 Type 5824 Actuator Mounting and Operating Instructions EB 5824-9 EN Edition June 2003 Contents Contents Page

More information

SK TU4-CAO-C Part number:

SK TU4-CAO-C Part number: SK TU4-CAO-C Part number: 275 281 151 CANopen External Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

EY-EM : Remote I/O module, ecolink

EY-EM : Remote I/O module, ecolink EY-EM 510...512: Remote I/O module, ecolink510...512 How energy efficiency is improved Optimum adjustment to applications by means of module technology. Reduction in wiring Features Part of the SAUTER

More information

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions

KNX T-UP. Temperature Sensor. Technical specifications and installation instructions EN KNX T-UP Temperature Sensor Technical specifications and installation instructions Elsner Elektronik GmbH Control and Automation Engineering Herdweg 7 D 75391 Gechingen Phone +49 (0) 70 56 / 93 97-0

More information

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E

GREISINGER electronic GmbH. D Regenstauf, Hans-Sachs-Straße 26. T-Logg 100. T-Logg 100 E E39.0.0X.6C-03 Data logger for temperature as of version V1.3 Operating Manual T-Logg 100 T-Logg 100 T-Logg 100 E GREISINGER electronic GmbH D - 93128 Regenstauf, Hans-Sachs-Straße 26 +49 (0) 9402 / 9383-0

More information

Zone monitoring device TGÜ-BS 2.6 (Slave) for car parks

Zone monitoring device TGÜ-BS 2.6 (Slave) for car parks Zone monitoring device TGÜ-BS 2.6 (Slave) for car parks Gas zone device with bus technology Up to 100 measuring points for CO, NO 2, LPG, CH 4 Additional measuring points with repeater Additional zone

More information

TF501, TF521 Terminal Bases

TF501, TF521 Terminal Bases Ordering Data DATA SHEET TF501, TF521 Terminal Bases 1 Ordering Data Part No. Scope of delivery Product life cycle status 1SAP 117 000 R0271 1SAP 317 000 R0271 1SAP 117 200 R0271 1SAP 317 200 R0271 TF501-CMS,

More information

GS202 Encoder Switch

GS202 Encoder Switch GS202 Encoder Switch 20:2 encoder switch 20 encoder inputs (TTL / RS422 standard) Input signals A, /A, B, /B, Z, /Z on each encoder input 2 x 6 control inputs (HTL / PNP) 2 encoder outputs (TTL / RS422

More information

Product and functional description

Product and functional description Product and functional description The RS 525/23 Universal Dimmer is a KNX device with one dimmer output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The bus

More information

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description

RAD-DO8-IFS. I/O extension module, eight digital transistor outputs. Data sheet. 1 Description I/O extension module, eight digital transistor outputs Data sheet 105364_en_00 PHOENIX CONTACT 2013-03-26 1 Description The I/O extension module can be used in conjunction with Radioline wireless modules

More information

RTD-NET Installation Instructions

RTD-NET Installation Instructions LED3 SW1 LED4 RTD-NET Installation Instructions 0V +V POWER 15-24VDC English RTD-NET Installation Instructions 100.00 RTD-NET Control Interface realtime Control Systems REMC P1 P2 RS485 D-BUS DB DA GND

More information

s Spring return C / max C

s Spring return C / max C echnical data sheet SF4A actuator for WORKS with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx. 4 m orque 0 Nm Nominal

More information

LRC-XDP. LRC-XDP Datasheet. LRC-XDP Display Panel for Toshiba air-conditioning units. Description

LRC-XDP. LRC-XDP Datasheet. LRC-XDP Display Panel for Toshiba air-conditioning units. Description Display Panel for Toshiba air-conditioning units Description The RealTime is a monitoring panel compatible with the Toshiba LG1 air-conditioning control interface. The XDP displays the current operating

More information

EY-RU : Room operating unit, ecounit

EY-RU : Room operating unit, ecounit Product data sheet 94.040 EY-RU 341...346: Room operating unit, ecounit341...346 How energy efficiency is improved Individual setting of occupancy and absence as well as a room setpoint correction and

More information

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide

INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS. KCD-400 Series. Installation Guide INDUSTRIAL 1000BASE-T TO 1000BASE-X MEDIA CONVERTERS KCD-400 Series Installation Guide DOC.060227-KCD-400-1- (C) 2005 KTI Networks Inc. All rights reserved. No part of this documentation may be reproduced

More information

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH

Industriefunkuhren. Technical Manual. Signal Converter. for DIN Rail Mounting Series 4800xx-yy ENGLISH Industriefunkuhren Technical Manual Signal Converter for DIN Rail Mounting Series 4800xx-yy ENGLISH Version: 01.01-19.07.2007 2 / 23 Signal Converter 4800 - V01.01 INPORTANT NOTES Downloading Technical

More information

RXTP ROOM TEMPERATURE

RXTP ROOM TEMPERATURE ROOM TEMPERATURE CONTROLLER WITH PI CONTROL Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4

More information

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O

TXM1.8T. Triac module Used for Thermic and motor-driven actuators (AC 24 V) TX-I/O s 8 179 8179p01 TX-I/O Triac module sed for Thermic and motor-driven actuators (AC 24 V) AC 24 V-controlled devices TXM1.8T 8 triac outputs (AC 24 V), configured individually for: Permanent contact Three-point

More information

Manual FC 3500 DC Fan Control

Manual FC 3500 DC Fan Control Manual FC 3500 DC Fan Control Description: FC 3500 DC Type: Manual File: Do150304 FC 3500 DC V12 EN.docx VDH Products BV Pages: By: Initials: 23 BVDB Doc.no: Version: Date: 150304 1.2 15-04-2015 Table

More information

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O

TXM1.8U TXM1.8U-ML. Universal modules TX-I/O s 8 173 TX-I/O niversal modules TXM1.8 TXM1.8-ML Two fully compatible versions: TXM1.8: 8 inputs/outputs with LED signal / fault indication TXM1.8-ML: As TXM1.8, but with additional local override facility

More information

R70 Ethernet to CAN interface Manual (1.4 EN)

R70 Ethernet to CAN interface Manual (1.4 EN) R70 Ethernet to CAN interface Manual (1.4 EN) General information R70 Ethernet to CAN interface Manual Version 1.4 EN, 04/2009, DOC01816 Copyright 2009 by d&b audiotechnik GmbH; all rights reserved. d&b

More information

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions

RST ROOM TEMPERATURE TRANSMITTER. Mounting and operating instructions Mounting and operating instructions Table of contents SAFETY AND PRECAUTIONS 3 PRODUCT DESCRIPTION 4 ARTICLE CODES 4 INTENDED AREA OF USE 4 TECHNICAL DATA 4 STANDARDS 4 OPERATIONAL DIAGRAM 5 WIRING AND

More information

Products no longer available

Products no longer available echnical data sheet NVF4-MF(-E)-R Modulating linear actuator with emergency function for -way and 3-way globe valves Actuating force 800 N Nominal voltage AC/DC 4 V Modulating control DC 0... 10 V Position

More information

Electronic Temperature Controller. Instruction Manual Version

Electronic Temperature Controller. Instruction Manual Version Electronic Temperature Controller 701 Instruction Manual Version 1.00.01 Dear Customer, we have made up this operating manual in such a way that all necessary information about the product can be found

More information

SK TU4-PBR Part number:

SK TU4-PBR Part number: SK TU4-PBR Part number: 275 281 100 PROFIBUS DP External Bus Interface The bus interface may only be installed and commissioned by qualified electricians. An electrician is a person who, because of their

More information

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007

Installation instructions Diagnostic electronics for vibration sensors VSE / / 2007 Installation instructions Diagnostic electronics for vibration sensors UK VSE00 70406 / 00 07 / 2007 Contents Safety instructions 3 Function and features 4 Mounting 4 Mounting of the sensors 5 Electrical

More information

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage

Operating and Installation Manual. EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Operating and Installation Manual EASYLAB Expansion modules Type EM-TRF for 230 V AC mains voltage Type EM-TRF-USV for 230 V AC mains voltage; provides uninterruptible power supply (UPS) The art of handling

More information

MC 11 EB-2 Power supply cabinet with external bus, AC version

MC 11 EB-2 Power supply cabinet with external bus, AC version MC 11 EB-2 Power supply cabinet with external bus, AC version USER/MAINTENANCE MANUAL 1 SLOT 0 SLOT 1 SLOT 2 SLOT 3 SLOT 4 SLOT 5 SLOT 6 SLOT 7 SLOT 8 SLOT 9 SLOT 10 SLOT 11 EB-2 (a) MC11 (b) (c) Figures

More information

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX

VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX D GB F I E NL. Installation and operating instructions Room thermostat VARIA 826 S KNX 307031 VARIA VARIA 826 S WH KNX VARIA 826 S BK KNX 8269210 8269211 GB Installation and operating instructions Room thermostat D GB F I E NL VARIA 826 S KNX Contents Basic safety instructions 3 Display

More information

Product and functional description

Product and functional description Product and functional description The RS 520/23 shutter / blind actuator is a KNX device with one relay output. The device is installed in an AP 118 Control Module Box or an AP 641 Room Control Box. The

More information

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2

dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Safety information 1 General 2 dv/dt filter compact plus Voltage Peak Limiter SINAMICS SINAMICS G120P dv/dt filter compact plus Voltage Peak Limiter Operating Instructions Safety information 1 General 2 Mechanical installation 3 Electrical

More information

Manual Control Unit GFC 32

Manual Control Unit GFC 32 Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control

More information

Compact universal controllers

Compact universal controllers 7 867 Compact universal controllers RWF55... The RWF55 is used mainly for controlling the temperature or pressure in oil- or gas-fired heating plants. If the relevant parameters are set, the RWF55 can

More information

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's

Operation Manual Profibus DP -Display HE 5120 P with digital I/O's Operation Manual Profibus DP -Display HE 510 P with digital I/O's "HESCH" Schröder GmbH Boschstraße 8 31535 Neustadt Telefon +49 (0) 503 / 9535-0 Telefax +49 (0) 503 / 9535-99 e-mail: info@hesch.de http://www.hesch.de

More information

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02

RXL24.1. Room controller RXL. Communicating controller for chilled ceiling and radiator applications CC-02 s 3 878 RXL Room controller RXL24.1 Communicating controller for chilled ceiling and radiator applications CC-02 The RXL24.1 room controller is used for temperature control in individual rooms. For chilled

More information

Product and functional description

Product and functional description Product and functional description The UP 525/13 Universal Dimmer is a KNX device with one dimmer output. The device is installed in a flushmount wall box (60 mm Ø, depth 60 mm) or an installation box.

More information

Manual and Protocol Description

Manual and Protocol Description Communication Module MSR240 1 Manual and Protocol Description Overview The MSR240 Communication Module serves as an interface between a MSR210 or MSR211 Basic Module and a standard serial data communication

More information

Industrial motor controller for brushed DC motors 24 VDC

Industrial motor controller for brushed DC motors 24 VDC Industrial motor controller for brushed DC motors 24 VDC Design for output currents up to 6 A Control with the following functions: - reversal of direction of rotation - overcurrent shutdown - overcurrent

More information

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter

Lantech IPGC-0101DSFP. User Manual. 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter Lantech IGC-0101DSFP IPGC-0101DSFP 10/100/1000T (PoE at) to 100/1000M SFP Industrial Switch Converter User Manual Dec 2016 Recommendation for Shielded network cables STP cables have additional shielding

More information

Room unit with PPS2 interface

Room unit with PPS2 interface 1 642 Desigo RX Room unit with PPS2 interface for use with: QAX33.1 devices of the ranges Desigo RXC, RXB, RXL, and RXA (PPS2) Desigo PX Automation stations 1) devices with a PPS2 interface Room temperature

More information

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide

Industrial 5-Port Fast Ethernet Switches. with SFP Slot and optional 4 PoE PSE Ports. Basic Model: KSD-541. PoE Model: KSD-541-HP. Installation Guide Industrial 5-Port Fast Ethernet Switches with SFP Slot and optional 4 PoE PSE Ports Basic Model: KSD-541 PoE Model: KSD-541-HP Installation Guide DOC.141201-1- (C) 2014 KTI Networks Inc. All rights reserved.

More information

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC

QAX50.1 QAX50.5 QAX51.1 QAX51.5. Flexible room unit. Desigo RXC 1 648 Desigo RXC Flexible room unit for integrated operation of HVAC, lighting and blinds in individual rooms; with LONMARK -compatible bus communication QAX50.1 QAX50.5 QAX51.1 QAX51.5 Room temperature

More information

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet

Controller module. Brief description. Features. Block structure. Page 1/7. Data Sheet JUMO GmbH & Co. KG Delivery address:mackenrodtstraße 14, 36039 Fulda, Germany Postal address: 36035 Fulda, Germany Phone: +49 661 6003-0 Fax: +49 661 6003-607 E-mail: mail@jumo.net Internet: www.jumo.net

More information

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station

RXM39.1. PL-Link IO Block. Desigo TRA. Use with PXC3 series room automation station s 3 836 3836P01 Desigo TRA PL-Link IO Block Use with PXC3 series room automation station RXM39.1 The PL-Link IO Block contains the inputs and outputs controlled by a room automation station via PL-Link.

More information

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency

Electrical data Nominal voltage AC/DC 24 V Nominal voltage frequency echnical data sheet GM24A-MOD Communicative damper actuator for adjusting dampers in technical building installations orque motor 40 Nm Nominal voltage AC/DC 24 V Control modulating,, hybrid mode Conversion

More information