9. External Control Adaptor for Outdoor Unit
|
|
- Darlene Hawkins
- 6 years ago
- Views:
Transcription
1 External Control Adaptor for Outdoor Unit OH0-1. External Control Adaptor for Outdoor Unit.1 DTA104A61 / DTA104A62 / DTA104A53 53 FXC(Q)... KRP1B6 FXFQ-P... KRP1H FXF, FXFQ-M... KRP1D FXH(Q)... KRP1C3 FXA(Q)... KRP4A3 FXD(Q)... KRP1B101 FXMQ-P... KRP4A6 C: 1PA63164D 22 Control Systems
2 OH0-1 External Control Adaptor for Outdoor Unit 2.1 DTA104A61 / DTA104A62 / DTA104A53 C: 1PA63164D Control Systems 22
3 External Control Adaptor for Outdoor Unit OH0-1 BSV(Q) FXK(Q) 1PA63164B-3 FXC(Q) FXS(Q) FXYB Note : Installation box is necessary for second adaptor (FXS). <Slim ceiling mounted duct type> FXZQ FXD(Q) 230 Control Systems
4 OH0-1 External Control Adaptor for Outdoor Unit FXMQ40~125MA FXM40~125 FXM(Q) FXH(Q) Adaptor PC Board Installation Box Cover (Optional Kit KRP1C3) Adaptor PC Board (DTA104A62) PCB Support 2.1 DTA104A61 / DTA104A62 / DTA104A53 Note: Installation box for adaptor PCB is required to install the adaptor. Adaptor PC Board Installation Box (Optional Kit KRP1C3) Note: For installation, the optional kit of adaptor PCB installation box is required. FXL(Q) FXN(Q) Control Systems 231
5 External Control Adaptor for Outdoor Unit OH Control Systems
6 OH0-1 External Control Adaptor for Outdoor Unit [Input signal] Constant a contact Input current is approx. 10 ma per contact. For the relay contact, use a weak current contact. [Outside wiring specifications] Recommended wiring:0.5-2 mm 2 sheathed wire Wiring length: Within 150 m Keep a minimum 50 mm from power supply wiring to prevent malfunction. Demand input terminal Short circuit between (Demand 1) - (C)...As a guideline, demand should be about 0%. Short circuit between (Demand 2) - (C)...As a guideline, demand should be about 40%. Short circuit between (Demand 3) - (C)...Forced thermo OFF Low-noise input terminal When terminals are short-circuited during cooling, capacity save (outdoor unit fan low-speed turn, compressor frequency control) is carried out. use only at night when load is slight. How to set demand control in the field 1. Outdoor unit field setting Setting mode 1...Turn ON low noise control as explained in the outdoor unit s service manual. Setting mode 2...Match low noise and demand addresses to the external control adaptor address. 2. External control adaptor settings Function switch (SS1) Set SS1 to either BOTH or DE. Address setting switch (DS1,DS2) Match DS1 and DS2 to the low noise and demand addresses of the outdoor unit. 2.1 DTA104A61 / DTA104A62 / DTA104A53 Control Systems 233
7 External Control Adaptor for Outdoor Unit OH Control Systems
8 OH0-1 External Control Adaptor for Outdoor Unit Fig. 1 Setting of 5-bit cool/heat address by DS1,2 2 Designate and set cool/heat addresses 0-31 for each operation mode switch unit. No. 0 No. No. No. 15 No. 16 No. 31 : OFF : ON Upper 2 bits DS2 Lower 3 bits DS1 CENTRAL LOWER C/H NO. ADRESS DEMAND CONTROL ADRESS.1 DTA104A61 / DTA104A62 / DTA104A53 Fig. 2 (Ex.) To set the outdoor unit s cool/heat address to No. 15 : Off On Flicker 5-bit When power turned on Procedure Setting contents MODE TEST Hold down next page button for 5 secs. Push operation button one time. Push confirmation button one time. Push operation button 15 times. (Address No. = Times pushed) Push confirmation button two times. Push next page button one time. Setting mode (factory set) Enters address setting. Enters cool/heat address setting. Make sure cool/heat address has been entered. Sets cool/heat address. Check cool/heat address. Returns to set mode. C/H SELECT IND MASTER SLAVE L.N.O.P. SEQ. START Fig. 3 (Ex.) To set the outdoor unit s demand address to No. : Off On Flicker 5-bit When power turned on Procedure Setting contents MODE TEST Hold down next page button for 5 secs. Push operation button two times. Push confirmation button one time. Push operation button times. (Address No. = Times pushed) Push confirmation button two times. Push next page button one time. Setting mode (factory set) Enters address setting. Enters demand address setting. Make sure demand address has been entered. Sets demand address. Check demand address. Returns to set mode. C/H SELECT IND MASTER SLAVE L.N.O.P. SEQ. START Control Systems 235
EEDEN technical data. air conditioning systems. Individual Control Systems
EEDEN08-204 technical data Individual Control Systems air conditioning systems 2e TABLE OF CONTENTS Individual control systems 1 Possible individual control systems.............................. 21 Survey................................................................
More informationSubmittal Data Sheet intelligent Touch Manager DCM601A71
For use with the following VRV Models: FXAQ, FXDQ, FXEQ, FXFQ, FXHQ, FXLQ, FXMQ, FXMQ_MF, FXNQ, FXTQ, FXUQ, FXZQ, VAM For use with the following Daikin SkyAir Models: FAQ, FBQ, FCQ, FHQ, FTQ Capacity:
More informationSYSTEM OUTLINE KRP4A Group control adapter PCB (installation box is necessary)
2.9. KRP4A51-52-53-54 Group control adapter PCB (installation box is necessary) Accessories Check if the following accessories are included in the kit. Relay harness PC board support x 4 x 1 (1) x 1 each
More informationDAIKIN. DS-net Engineering Data
DS-net Engineering Data 1. Overview -For A/Cs used to cool facilities such as unmanned relay stations -Local control (*1) for uninterrupted operation, backup operation, rotation operation, etc. -Remote
More informationINSTALLATION MANUAL. Modbus interface PCB kit EKFCMBCB7
INSTALLATION MANUAL 1 1 A B C 5 INSTALLATION MANUAL Modbus interface PCB Kit 1 1 SS1 SS OFF ON 5 CONTENTS page Content of kit... Name of parts... Specification of communication wires... Installation method
More informationINSTALLATION MANUAL. Remote controller BRC315D7
INSTALLATION MANUAL 2 3 4 2 2 S M S M PCB J5 J8 2 3 5 4 5 6 6 7 P2 P P2 P a d 2 b c 4 3 UNIT No. GROUP SETTING e 3 7 4 5 6 7 6 5 2 READ THIS MANUAL ATTENTIVELY BEFORE STARTING UP THE UNIT. DO NOT THROW
More informationtechnical data Systems Individual control systems
technical data Systems Individual control systems Individual control systems 17 1 Possible individual control systems...2 2 BRC2A51 - Simplified remote control Explanation of buttons and functions... 3
More informationINSTALLATION MANUAL For authorized service personnel only.
AIR CONDITIONER SIMPLE REMOTE CONTROLLER (WIRED TYPE) UTY-RSNUM INSTALLATION MANUAL For authorized service personnel only. English Français Español Contents. SAFETY PRECAUTIONS...2 2. ACCESSORIES...2 3.
More informationWireless Remote Controller Kit
INSTALLATION MANUAL Wireless Remote Controller Kit LS BRC4C8 Read these instructions carefully before installation. Keep this manual in a handy place for future reference. This manual should be left with
More informationUSER S MANUAL. FX2N-32DP-IF Profibus-DP Interface Unit
USER S MANUAL FX2N-32DP-IF Profibus-DP Interface Unit FX2N-32DP-IF Profibus-DP Interface Unit Foreword This manual contains text, diagrams and explanations which will guide the reader in the correct installation
More informationDESIGN & TECHNICAL MANUAL
AIR CONDITIONER Duct type DESIGN & TECHNICAL MANUAL INDOOR ARYG72LHTA ARYG90LHTA OUTDOOR AOYG72LRLA AOYG90LRLA DR_AR012EF_03 2017.04.07 Notices: Product specifications and design are subject to change
More informationControl system. Type FSL-CONTROL II. Modular, stand-alone room control system, specially for decentralised ventilation systems (with bus communication
X X testregistrierung Control system Type Central BMS interface DCP-FSL II-Stand-alone Pressure independent control valve Straight-way valve Modular, stand-alone room control system, specially for decentralised
More informationIntercom Installation The b-red. KIT audio entry control systems AKW200/201
Intercom Installation The b-red KIT audio entry control systems AKW200/201 What is the b-red 2 wire system? The b-red is an entry level intercom system, It makes use of digital technology and as such communication
More informationQUICK REFERENCE. Remote controller BRC1E51
QUICK REFERENCE 1 2 3 4 1 2 1 2 6 9 2 3 4 5 7 6 8 1 10 mm L 120 19 120 mm 2 2 5 7 1+2 2 1 3 7 5 4 2 6 8 8.1 P1 P2 1 8.2 P1 P2 1 PCB 2 PCB 2 5 3 3 4 5 1x 1x 4 8.4 8.1 8.4 8.2 8.3 8.4 4 4 5 P1 P2 1 5 P1
More information9.5 nominal torque 4.5 W 16 VA. Min. 30 nominal voltage Min. 30 Nm. Reversible with switch By mounting. MIN (minimum position)
echnical data sheet EF24A- Communicative spring return actuator with emergency function for adjusting air dampers in ventilation and air conditioning systems in buildings For air dampers up to approx.
More informationInstallation Manual. DZK BACnet
Installation Manual DZK BACnet InterfacepbilCodarPageNumber TABLE OF CONTENTS Page Overview... 5 Outline and Features... 5 System outline... 5 Specifications and device elements... 6 Functional specifications...
More information3. The circuit is composed of 1 set of Relay circuit.
Part Number : Product Name : FK-FA1420 ONE CHANNEL 12V RELAY MODULE This is the experimental module for a relay controller as the fundamental controlling programming. It is adaptable or is able to upgrade
More informationControl. Systems. Climate comfort. All Seasons. Heating. Air Conditioning. Applied Systems. Refrigeration
Control All Seasons Climate comfort Systems Heating Air Conditioning Applied Systems Refrigeration Daikin Europe N.V. ABOUT DAIKIN Daikin has a worldwide reputation based on 85 years experience in the
More informationSINGLE. Technical Data Book Zone Control Systems
SINGLE Technical Data Book Zone Control Systems Zone control system 2 I. Zone control system 1 Zone controller & remote temperature sensor 1. MWRZS00 / MWRZS10 / MRWTS 1) Features.... 4 2) Product specification...
More information7. PCB AND FUNCTIONS
Contents. PCB AND FUNCTIS. Outdoor Unit Control PCB... - -. Outdoor Unit Control PCB CR-C0DXH... - -. Outdoor Unit FAN PCB FAN-C00DXH... - -. Outdoor Unit FAN PCB FAN-C0DXH... - -. Outdoor Unit Filer PCB
More informationAC Power Management field for 20 years Expanding to Complement and Protect DSP Processors, Amplifiers, and IP Products Innovation, Protection,
AC Power Management field for 20 years Expanding to Complement and Protect DSP Processors, Amplifiers, and IP Products Innovation, Protection, Convenience, Value Sequencers ETA-S15L 15A / 1800W Power Conditioning
More informationQuick installation guide
Quick installation guide Subject Ref. No. Vers. Ziehl Abegg EC-Blue motors quick configuration guide 1.0 1 / 3 Issued by Department D. Rizzotti Air Business Center Approved by Location Date 23/05/2013
More informationMAKING MODERN LIVING POSSIBLE. Installation Guide. Twin Kit 086L
MAKING MODERN LIVING POSSIBLE Installation Guide 086L70 www.heating.danfoss.com Danfoss A/S is not liable or bound by warranty if these instructions are not adhered to during installation or service. The
More informationMM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning
MM-A20 BMS Interface for Mitsubishi Electric Split Air-Conditioning Installation and User Guide www.microtrol.co.uk Contents 1. Supplied Parts...2 2. Important Information...3 3. Product Overview...4
More informationC7110C1001A / C7110D1009A WALL MODULES
HONEYWELL EXCEL 5000 OPEN SYSTEM GENERAL The C7110C1001A and C7110D1009A are combined CO2 / temperature wall modules designed for applications in indoor ventilation and air conditioning systems. In conjunction
More informationWizard- 3 Controller to Optional Track 1-4 Playback Set-up
Wizard- 3 Controller to Optional Track 1-4 Playback Set-up 09/24/09 REM-CH Header PINS Not Used 1-Pin G-Pin Track 1-4 ming Selection Switches Momentary Push Button () () () () Toggle Switch Toggle Switch
More informationDowngrade DVM S models for DVM +2 or +3 systems. DVM +2 or DVM +3 ODU or DVM+3 indoor units. No spare parts available or repairs are not possible.
Date: 05/02/2017 Subject: Downgrade DVM S models for DVM +2 or +3 systems Models: DVM S 6-12 Ton Heat Pump Models Downgrade DVM S models for DVM +2 or +3 systems When do we need this? - When an older system
More informationSwitching Power Supply
Switching Power Supply Highly Reliable and Full-functioned 1-year Life Expectancy, 12, 1, or 24 V output voltages, and 30, 60, 0, or 10 W power ratings. 8 to 132 VAC or 170 to 264 VAC switchable input
More informationSpeak to and see your visitor from your smart-phone. Easy wireless connection to existing home Wi-Fi. Up to 60 metre range with included directional
Speak to and see your visitor from your smart-phone. Easy wireless connection to existing home Wi-Fi. Up to 60 metre range with included directional antenna (dependant on location of router in house).
More informationTwo remote controller system with one Lossnay Basic System (Refer to page C-10) Multiple Lossnay units with one remote controller.
Control CHAPTER 1 System Design 1. System Examples One with one remote Multiple units with one remote Two remote system with one Basic System (Refer to page C-10) Non-polar Two wires Power supply Remote
More informationWiring Diagrams INDEX. UNIT DESCRIPTION DRAWING NUMBER FIG. NO. 09DK Field Wiring 09DK DK054,064
09DK054-094 Air-Cooled Condenser Units 50/60 Hz Wiring Diagrams INDEX UNIT DESCRIPTION DRAWING NUMBER FIG. NO. 09DK054-094 Field Wiring 09DK500319 1 09DK054,064 Wiring Diagram and Component Arrangement
More informationOwner's Manual. Carrier TOSH BA REMOTE CONTROLLER FOR AIR CONDITIONER (SPLIT TYPE) Wireless remote controller kit TCB-AX21 UL
TOSH BA Carrier REMOTE CONTROLLER FOR AIR CONDITIONER (SPLIT TYPE) Owner's Manual Remote Controller Model name: Wireless remote controller kit TCB-AX21 UL Generic model name Wireless remote controller
More informationRCF-230CD. Communicating room thermostat for fan-coil applications with on/off outputs
revision 11 2013 RCF-230CD Communicating room thermostat for fan-coil applications with on/off outputs RCF-230CD intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint and fan
More informationECON-ZIP-BASE. ZIP Economizer Base Module
ECON-ZIP-BASE ZIP Economizer Base Module You can mount the ZIP Economizer in any orientation; it is recommended that you mount it in a position that will allow full utilization of the LCD and key pad and
More informationCOMFORT CONTROL CENTER SERVICE INSTRUCTIONS
USA SERVICE OFFICE Dometic Corporation 2320 Industrial Parkway Elkhart, IN 46516 574-294-2511 CANADA Dometic Corporation 46 Zatonski, Unit 3 Brantford, ON N3T 5L8 CANADA 519-720-9578 For Service Center
More informationNetworkable Dual Duct VAV Controller Specification and Installation Instructions
Controller Models EVCBM14NIT2S (Master controller / 2 TRIACs) EVCS14N (Slave controller) TRL Series Thermostat TRL24 (Room Sensor: Temp) TRLH24 (Room Sensor: Temp and %RH) TRLG24 (Room Sensor: Temp and
More informationDigital Keypad Introduction
K2 Digital Keypad Introduction The K02 uses the latest microprocessor technology to operate door strikes and security systems that require a momentary (timed) or latching dry contact closure. All programming
More informationPA5000 SERIES USER MANUAL
PA5000 SERIES 4G CELL PHONE ENTRY SYSTEM USER MANUAL Rev. C Platinum Access Systems Inc. PRODUCT LINE PA5020 --- Cell Phone Entry System PA5022 --- Cell Phone Entry System (Flush Mount) SPECIFICATIONS
More informationINTERFACE SPECIFICATION
INTERFACE SPECIFICATION MODBUS CONVERTOR UTY-VMGX PART NO. 9708438030 Modbus is registered trademarks of Schneider Electric SA. LONWORKS is registered trademark of Echelon Corporation in the United States
More informationRCF-230CAD. Communicating room controller for fan-coil applications with two analogue V DC outputs
revision 01 2015 RCF-230CAD Communicating room controller for fan-coil applications with two analogue 0...10 V DC outputs RCF-230CAD intended to control heating and/or cooling in 2- or 4-pipe installations.
More informationTechnology is nothing without control
46 Technology is nothing without control An innovative and complete range of integrated controls for application in the Toshiba VRF MiNi-SMMS, SMMS, SHRM systems ensures maximum comfort and excellent performance
More informationRCF-230CAD. Room controller with communication for fancoil applications with two analogue V DC outputs
revision 04 2016 RCF-230CAD Room controller with communication for fancoil applications with two analogue 0...10 V DC outputs Intended to control heating and/or cooling in 2- or 4-pipe installations. Setpoint
More informationThe PanasonicVRF Driver
The PanasonicVRF Driver The PanasonicVRF driver interfaces to a Panasonic or Sanyo variable refrigerant flow (VRF) air conditioning system. Compatible VRF systems include Panasonic ECOi, ECO G, and Sanyo
More informationInnovative Electronics for a changing world MANUAL POE 4+4 GM
Innovative Electronics for a changing world MANUAL POE 4+4 GM Index: Description Technical and connections Screen shots Physical Description: The POE 4 +4 GM is an 4+4 = 8 Channel Gigabit DC passive power
More informationINSTALLATION INSTRUCTIONS
Wired Remote Controller 7 Day Programmable Ductless Systems KSACN0401AAA (High Wall Models) KSACN0501AAA (Ducted/Cassette Models) INSTALLATION INSTRUCTIONS NOTE: Read the entire instruction manual before
More informationOutdoor Motorized Dome. Quick Installation Guide 86085A
Outdoor Motorized Dome Quick Installation Guide 86085A3340020 Outdoor Motorized Dome Quick Installation Guide Please follow the installation steps below to set up Outdoor Motorized Dome IP Camera. Check
More informationManual Control Unit GFC 16
Manual Control Unit 1400003_EN/04.2017 Index 1. Main features 3 2. Tekniske data 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 5 7. Remote 7 8. Shut down
More informationLED Driver Constant voltage. Driver LC 200W 24V SC SNC essence series
Driver essence series Product description LED Driver Output voltage 24 V Max. output power 2 W Dimmable via PWM LED dimmers Nominal life-time up to 5, h 5-year guarantee Typical application Cove lighting,
More informationZAVIO Outdoor IR Mini Dome. Quick Installation Guide
ZAVIO Outdoor IR Mini Dome Quick Installation Guide 0 Quick Installation Guide Please follow the installation steps below to set up your IP Camera. Check the package contents with the list below. See P.1
More informationWiring diagrams. Wiring diagrams for installers and planners. 1 LUXOMAT PD1, PD2, PD4, PD5-Clip and Indoor180 Master- and Slave 2 LUXOMAT PD2-24V
Wiring diagrams Wiring diagrams for installers and planners 1 UXOMAT PD1, PD2, PD4, PD5-Clip and Indoor180 Master- and Slave 2 UXOMAT PD2-24V 3 UXOMAT PD1-DIM, PD2-DIM, PD4-DIM, PD3-2C-E 4 UXOMAT PD4,
More informationFX1N-4EX-BD Input Expansion Board
Input Expansion Board USER S MANUAL JY992D95001C This manual contains text, diagrams and explanations which will guide the reader in the correct installation, safe use and operation of the FX 1N-4EX-BD
More informationINFORMATION ON REPAIRS OF PART
IFORMATIO O REPAIRS OF PART In case of replacing the parts shown in the Current spec. column, please use the parts shown in the Substitute spec. column referring to the instructions below. Item: Micro
More informationComplete Installation manual
VapoChill TM CPU Cooling System - LightSpeed [AC] TM asetek Inc. Complete Installation manual Date Version Comments 01-04-2004 1.0 1 Installing the VapoChill LightSpeed [AC] TM Preparing the case Step
More informationLossnay Remote Controller
Remote Controller . Summary Technical manual detailing the control and operation of commercial-type units (LGH-RX5-E Series). Possible System Configurations () When using only the remote. (2) Linking
More informationMiG2 CONTROLLERS. 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities
MiG2 CONTROLLERS 2 & 4 Stage General Purpose Controllers, with Air-conditioning Facilities The MiG2 controllers incorporate: 2 Inputs (Configurable as Resistive, 0 10V, 0 20mA or 4 20mA) 2 or 4 Relay Outputs
More informationRoom controller STRA-17
Room controller STRA-17 Application example Room 2 Room 3 Room 4 SCADA EXOline alt. RS485 Modbus Transformer STRZ-24 (Required component) STRA-17 is a preprogrammed room controller intended to control
More informationSYSMAC Remote Transistor Module
9 SYSMAC Remote Transistor Module Ultra-compact Remote I/O Modules to Match Most Applications 1 4-point, 8-point and 16-point models 1 4-point models measure 82 W x 32 D x 64.5 H mm; 8- and 16-point models
More informationManual Control Unit GFC 32
Manual Control Unit 1400004_EN/05.2017 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections 5 6. Settings 6 7. Remote control
More informationDip Switch settings.
Smart Temp Australia P/L EC 02 Multifunction Module Instruction Manual Ver 1.0 Preface The EC 02 module is a dedicated companion module for exclusive use with the Smart Temp SMT 770 thermostat (firmware
More informationR1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)
INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below. If
More informationLED Driver Constant voltage. Driver LC 35W 24V SC SNC essence series
Driver LC 35W 24V SC SNC essence series Product description LED Driver Output voltage 24 V Max. output power 35 W Dimmable via PWM LED dimmers Nominal life-time up to 50,000 h 5-year guarantee Typical
More informationINDOOR UNIT CONTROLLER (IUC) Operation Manual
INDOOR UNIT CONTROLLER (IUC) Operation Manual Date: 9 June 2015 Issue: 4 Note: Information in this document applies to IUC controllers programmed with software version 1.5. Page 1 of 11 Contents 1. Introduction...
More informationMitsubishi Electric Air-conditioner Network System
Mitsubishi Electric Air-conditioner Network System Central Controller Model: GB-50A Installation Manual Contents 1. Safety Precautions to be Observed without Fail...1 2. Confirmation of Parts...3 3. Product
More informationDAY AND NIGHT COLOR CAMERA
INSTRUCTION MANUAL DAY AND NIGHT COLOR CAMERA MODEL HDC518 Copyright 2007 Clover Electronics U.S.A. All Rights Reserved. PRECAUTIONS To avoid electrical shock, do not open the case of this product. Operate
More informationINSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST
INSTALLATION INSTRUCTIONS ECONOMIZER WITH EXHAUST MODEL WGSEIFM-5 For Use with Bard 3 through 5 Ton Step Capacity Wall Mount Air Conditioners with Gas Heat Bard Manufacturing Company, Inc. Bryan, Ohio
More informationUser Manual. EventCUBE CW/WW
User Manual EventCUBE CW/WW Introduction: Thank you for your purchase. The EventCUBE CW/WW is a DMX intelligent LED Pin Spot light. This LED Pin Spot light is for the serious production company looking
More informationAS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input
Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20
More information2M IR Mini Dome Quick Installation Guide
1 2M IR Mini Dome Quick Installation Guide Please follow the installation steps below to set up 2M IR Mini Dome IP Camera. Check the package contents against the list below. See P.1 Physical overview.
More informationLUXOMAT Schematics for electricians and consultants
B.E.G. WIIG DIAGAMS FO MOTIO- AD OCCUPACY DETECTOS UXOMAT Schematics for electricians and consultants Index Wiring diagrams for outdoor and ceiling-mounted motion detectors Wiring diagrams for wall-mounted
More information2003 Nissan Pathfinder SE
Fan Control Amplifier The fan control amplifier is located on the cooling unit. The fan control amp. receives a gate voltage from the auto amp. to step-lessly maintain the blower fan motor voltage in the
More informationW i F i P r e d a t o r 2
W i F i P r e d a t o r 2 W i - F i V i d e o I n t e r c o m Existing Wi-Fi hub Long range antenna (up to 60m working range depending on router type and location)! Search: WIFI PRO 2 OR Scan QR Code Simple
More informationFile E Project 98NK15665A. Issued January 26, 1999 Revised December 21, 2016 REPORT
File E193475 Project 98NK15665A Issued January 26, 1999 Revised December 21, 2016 REPORT on TRIP DEVICES FOR USE IN LOW VOLTAGE AC POWER CIRCUIT BREAKERS Under The Classification Program Utility Relay
More informationProduct Family: Electro Mechanical Relays Number: AN-LC-008
APPLICATION NOTE THIS INFORMATION PROVIDED BY AUTOMATIONDIRECT.COM TECHNICAL SUPPORT These documents are provided by our technical support department to assist others. We do not guarantee that the data
More informationR-150 DMX Light Source
R-150 DMX Light Source Instruction Menu Thank You for purchasing the R-150 DMX LIGHT SOURCE. Please read carefully the instruction menu before using the R-150 DMX LIGHT SOURCE. If you have any questions
More informationOperating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC /00 07/2017
Operating instructions ClassicLine module AC5204 / AC5209 / AC5212 AC5235 / AC5236 / AC5237 AC5274 7390889/00 07/2017 Contents 1 Functions and features...3 2 Operating and display elements...3 3 Installation...4
More informationSAMURAI SCAN 50 LED-SC50D. User Guide. Innovation, Quality, Performance. Professional Entertainment Technology 19-
SAMURAI SCAN 50 LED-SC50D Innovation, Quality, Performance User Guide Professional Entertainment Technology 19- EC Declaration of Conformity We declare that our products (lighting equipments) comply with
More informationTECHNICAL MANUAL (CONTROLS) Models. Lossnay Unit. Lossnay Remote Controller LGH-150RX3-E LGH-25RX3-E LGH-35RX3-E LGH-50RX3-E LGH-80RX3-E LGH-100RX3-E
TECHNICAL MANUAL (CONTROLS) Models Unit LGH-15RX3-E LGH-25RX3-E LGH-35RX3-E LGH-50RX3-E LGH-80RX3-E LGH-100RX3-E LGH-150RX3-E LGH-200RX3-E Remote Controller PZ-41SLB-E PZ-52SF-E CONTENTS 1. Summary...............................................................................
More informationR1M-GH BEFORE USE... POINTS OF CAUTION INSTRUCTION MANUAL PC RECORDER MODEL. (thermocouple or DC input, 16 points)
INSTRUCTION MANUAL PC RECORDER (thermocouple or DC input, points) MODEL RM-GH BEFORE USE... Thank you for choosing M-System. Before use, please check contents of the package you received as outlined below.
More informationINSTRUCTION MANUAL A141 High Level Audible Warning System
24V DC (18V to 30V DC range) 115 or 230VAC (90V to 264V AC range) Operating Temp: -20 to +55 C IP Rating: IP65 Marking: 3) Installation Requirements 1) Introduction The A141 high level audible warning
More informationManual Simatek Control Unit GFC 32
Manual Simatek Control Unit GFC 32 Original instructions 1400004_GB Ver. 2014.01.09 Index 1. Main features 3 2. Technical features 3 3. Installation guidelines 4 4. Preliminary checks 5 5. Electrical connections
More informationOPERATION INSTRUCTIONS
2018 Lennox Industries Inc. Dallas, Texas, USA OPERATION INSTRUCTIONS V0STAT52 Wireless Indoor Unit Controller CONTROLS 507459-04 05/2018 This manual must be left with the owner for future reference. IMPORTANT
More information3. Alignment and Adjustments
3. 3-1 Test Mode How to Approach Test Mode You can approach the Test Mode by pressing the on/off switch of indoor unit for 5 seconds. on/off switch Test Mode Operation Option After installing the air conditioner,
More informationInBin-P Pressure switches from 5 Pa Pa
InBin-P Pressure switches from 5 Pa...100 Pa Electrical, binary pressure or differential pressure switches with adjustable switch activation delay 24 VAC/DC supply voltage, potential free switching contact
More informationIndication and Adjustment Product Information VEGADIS 61. Level Switching Pressure
Indication and Adjustment Product Information VEGADIS 61 Level Switching Pressure 2 VEGADIS 61 Contents Contents 1 Product description...4 1.1 Configuration... 4 1.2 Principle of operation... 4 1.3 Adjustment...
More informationTIME DELAY RELAYS Product Summary
Product Summary Macromatic offers a wide variety of time delay relays and accessories. Each one has different features and operating characteristics, allowing you to choose the exact product to meet your
More informationSTRA-17 Room controller. Installation and maintenance manual. Content
Content Installation preparations... Wiring diagram...3 Display handling...5 Technical data...6 Configuration...7 Operating modes...7 Controller modes...7 Activation operating modes...7 Control states...8
More informationMultiple Output Linear DC Power Supply
Multiple Output 180W~315W Introduction The TP2000 and TP2000TK series are linear DC power supplies with 3 channels, 195W to 315W output. In constant voltage and current operations, the power supply provides
More informationCONTROLLER INSTALLATION OPERATION & QUICK START
CONTROLLER INSTALLATION OPERATION & QUICK START Controller: 8403-066 ECU Series Controller Manual: 2100-559 Supersedes: NEW File: Tab 19 Date: 05-02-11 Page 1 of 6 TABLE OF CONTENTS Installation Note...
More informationMODEL: M5DY SEN TRONIC AG CURRENT LOOP SUPPLY. [2] POWER INPUT AC Power M: V AC (Operational voltage range V, Hz)
Super-mini Terminal Block Signal Conditioners M5-UNIT CURRENT LOOP SUPPLY Functions & Features Powering a 0 ma DC current loop Applicable to smart transmitters Isolation between the input and output Fast
More informationi.shine 3148 RGBW Color Stainer XP USER MANUAL
i.shine 3148 RGBW Color Stainer XP USER MANUAL Thank you very much for choosing our product. For safety purpose, please read this manual carefully before your operation. This manual included installation
More informationExBin-D Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh)
Transducers for ExPro-B... sensors (probes) ExPro-B... Thermostats / humidistats ( C, % rh) Electrical, explosion proof transducers only connectable to ExPro-B... thermostats and humidistats 24 VAC/DC
More informationLossnay Energy Recovery Ventilator
Energy Recovery Ventilator MODELS: LGH-5RVX-E, LGH-5RVX-E, LGH-35RVX-E LGH-5RVX-E, LGH-65RVX-E, LGH-8RVX-E LGH-RVX-E, LGH-5RVX-E, LGH-RVX-E Installation Instructions (For use by dealer/contractor) English
More informationCommunications & Networking
is a type of field bus that is primarily intended to be used to control sensors and actuators. is a network system that is compatible with the IEC62026 standard. A master device can communicate with slave
More informationMODEL: R2K-1 SEN TRONIC AG. R2K Series
1 MODEL: R2K-1 R2K Series /RS-485 CONVERTER Functions & Features Bidirectional converter between and RS-485 used when connecting Modbus RS-485 devices to a PC CE marking Standard: Conforms to, EIA Transmission
More informationOperating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC /00 02/2015
Operating instructions ClassicLine module AC5203 / AC5205 AC5208 / AC5211 AC5213 / AC5214 AC5215 / AC5233 AC5294 80226775/00 02/2015 Contents 1 Preliminary note...3 2 Safety instructions...3 3 Functions
More informationMOS FET Relay. Ordering Information. Application Examples G3VM- XN(F)/4N(F)
MOS FET Relay G3VM- XN(F)/4N(F) SSR for Switching Analog Signals, with an I/O Dielectric Strength of 2.5 kvac Using Optical Isolation Switches minute analog signals. Linear voltage and current characteristics.
More informationWiring Inside the card reader you will see a circuit board. The connections are as follows:
Power Adaptor (12VDC, Max. Current: 1A) If you purchased the Cardlock Series power supply cut the head of the adaptor and strip the insulation. If your locking mechanism, electric strike or magnetic lock
More informationIO-INTERFACE. Procon. INSTALLATION MANUAL Version 1.01 MITSUBISHI ELECTRIC FOR INSTALLERS
Procon IO-INTERFACE FOR INSTALLERS INSTALLATION MANUAL Version 1.01 For safe and correct use, please read this installation manual thoroughly before installing the PROCON IO-INTERFACE. MITSUBISHI ELECTRIC
More informationi.shine 1136 RGBW Color Stainer CN USER MANUAL
i.shine 1136 RGBW Color Stainer CN USER MANUAL Thank you very much for choosing our product. For safety purpose, please read this manual carefully before your operation. This manual included installation
More informationINSTALLATION MANUAL Wired Remote Control
INSTALLATION MANUAL Wired Remote Control MWR-SH00 System Air Conditioner E DB98-28133A(1) Safety Precautions This installation manual describes how to install the wired remote control. For installation
More information