1 Quick reference guide to using the Elgar PIP9012A series plug in programmers. Some of the features described herein are options installed on the power source and/or the PIP9012A. The following section will help in determine the presence of these options. (Note: Many Elgar sources and plug in modules are modified to meet special requirements. This document is ment to cover only the standard products. Contact Elgar for information if any questions regarding operation or identification of non standard products arise. Power source options These options are the Output Disconnect Relay and the Range Change Relay options. These can be identified as follows: Output disconnect relay: The letter "D" will appear in the model number as shown on the nameplate. i.e. 1001SL-12D or 501SX-14D. Range change relay: The number 4,8,5 will appear in the model number on the nameplate in the second digit after the first dash number. i.e. 1001SL-14 or 1001SX Test option: The letter "T" will appear in the model number as shown on the nameplate. i.e. 1001SL-12T or 501SX-14T. PIP9012A Options On the PIP9012A series, the TEST option is identified by the letter T appearing on the nameplate: i.e. PIP9012A-1T or PIP9012A-3T PIP9012A-1T-101.
2 Quick Reference PIP9012A Keyboard Operation, Basic Figure 1 PIP9012A series keypad and display Voltage program Four number keys must be pressed, followed by the [#] key then [1] key. In voltage program, the decimal point is always located between the third and fourth digits. ie. XXX.X To set volts: [1][3][1][5][#][1] To set volts: [1][3][0][0][#][1] To set 46.5 volts: [0][4][6][5][#][1] Frequency program Four number keys must be pressed, followed by the [#] key then [6] key. The location of the decimal point is dependent on the frequency range Selected: (see Changing Frequency Ranges) Hz range: between second and third digit XX.XX Hz range: between third and fourth digit XXX.X Hz range: to the right of the fourth digit XXXX. To set 47.75Hz in the Hz range [4][7][7][5][#][6]
3 To set 475.8Hz in the Hz range [4][7][5][8][#][6] To set 4500Hz in the Hz range [4][5][0][0][#][6] Changing Frequency Range One number key must be pressed, followed by the [#] key then [7] key. To set Hz range: [0][#][7] To set Hz range: [1][#][7] To set Hz range: [2][#][7] Note: Default values for each range are set on power up: Hz range: 60.00Hz Hz range: 400.0Hz Hz range: 0400Hz (Power up default range and frequency) Changing Voltage Range One number key must be pressed, followed by the [#] key then [8] key. To set program range to volts: [0][#][8] To set program range to volts: [1][#][8] 260V LED on display lights (to be used with sources having and volt ranges) NOTE: If power source is equipped with range change relays, the PIP9012A will toggle the output configuration accordingly. If the source is not equipped with range change relays, the jumpers on the source must be set for the same range as selected. The output voltage is automatically dropped to zero to prevent relay contact arcing and damage to loads powered by source. The voltage must be reprogrammed. Output Disconnect Relay Control One number key must be pressed, followed by the [#] key then [3] key. Open the output relay: [0][#][3] Close output relay: [1][#][3] CLS LED on display lights To Recall Programmed Values
4 The [*] key must be pressed, followed by [1],[6], or [9] To recall programmed voltage [*][1] To recall programmed frequency [*][6] To recall programmed current limit [*][9] NOTE: Current limit programming / recall will not function unless the PIP9012A is equipped with a TEST option and the power source are both equipped with the TEST option To Measure A single number key pressed followed by [#] key then the [4] key. To measure frequency: [0][#][4] To measure A phase voltage: [1][#][4] To measure B phase voltage: [2][#][4] To measure C phase voltage: [3][#][4] To measure A phase current: [4][#][4] To measure B phase current: [5][#][4] To measure C phase current: [6][#][4] To measure A phase wattage: [7][#][4] To measure B phase wattage: [8][#][4] To measure C phase wattage: [9][#][4] The display will continuously update reading until another key is pressed. Note: The measure function is available only if the PIP9012A is equipped with the test option and the power source is equipped with the test option. To set a current limit Four number keys must be pressed, followed by the [#] key then [9] key. In current limit program, the decimal point is always located between the second and third digits. i.e. XX.XX To set a limit of 5.5A: [0][5][5][0][#][9] To set a limit of 12.0A: [1][2][0][0][#][9] To set to max limit: [0][0][0][0][#][9] Note: The current limit will not function if the measurement function is in operation.
5 Note: The current limit function is available only if the PIP9012A is equipped with the test option and the power source is equipped with the test option. PIP9012A Operation, Advanced Line cycle drop out programming the PIP9012A Drop a number of line cycles The function of the drop key is dependent on the setting of jumper W1 on PIP9012A main board. In order to drop full cycles, the jumper labeled W1 on the main board must be set to the alternate position. NOTE: When the alternate jumper position is selected, several important changes occur. 1) The ZERO command still causes the voltage change to occur at zero crossing, but it now will do so only on a positive going edge. 2) The PEAK command will no longer effect a voltage change on the peak of a wave, but will change on a zero crossing only on a negative going edge. 3) If the test option (The letter T designation in the model number)is installed, the command FREQ command will read back 1/2 of the true frequency. If R25 on the Test Board is increased to 21K, then R23 will calibrate FREQ readback properly while in the full drop cycles mode (jumper W1 installed). 4) The DROP n command will now drop a full cycle for each integer value from 1 to 9. The drop will occur at zero crossing only on a negative going edge. 5) The ON 1 command will now start at zero crossing on a positive going edge. 6) The ON 2 command will now start at a zero crossing on a negative going edge. 7) The ON 0 and OFF commands function is not altered.
6 1/2 cycle drop out programming the PIP9012A In order to drop 1/2, the jumper labeled W1 on the main board is left in the normal position. 8) The ZERO command causes the voltage change to occur at zero crossing on a random positive or negative going edge. 9) The PEAK command will effect a voltage change on the peak of a wave random positive or negative going edge. 10) The DROP n command will now drop a 1/2 cycle for each integer value from 1 to 9. The drop will start at a peak on a random negative or positive going edge. 11) The ON 1 command will now start at zero crossing on a random positive going or negative going edge. 12) The ON 2 command will now start at a peak on a random negative or positive going edge.
7 PIP9012A Remote Operation, Basic Voltage Program String format: VOLTS <floating point value> To set volts: VOLTS To set volts: VOLTS 130 To set 46.5 volts: VOLTS 46.5 To set 156 volts: VOLTS 1.56E+2 Frequency Program String Format: FREQ <floating point value> To set 47.75Hz FREQ To set 475.8Hz FREQ To set 4500Hz FREQ 4500 Changing Frequency Range String Format: RNGF <x> x=0 for Hz range x=1 for Hz range x=2 for Hz range To set Hz range: RNGF 0 To set Hz range: RNGF 1 To set Hz range: RNGF 2 Note: Default values for each range are set on power up: Hz range: 60.00Hz Hz range: 400.0Hz Hz range: 0400Hz (Power up default range and frequency) Changing Voltage Range String format: RNG <y> y=0 for 0-135vac range y=1 for 0-270vac range To set program range to volts: RNG 0 To set program range to volts: RNG 1
8 (to be used with sources having and volt ranges) NOTE: If power source is equipped with range change relays, the PIP9012A will toggle the output configuration accordingly. If the source is not equipped with range change relays, the jumpers on the source must be set for the same range as selected. The output voltage is automatically dropped to zero to prevent relay contact arcing and damage to loads powered by source. The voltage must be reprogrammed. Closing Output Disconnect Relay String format: CLS Note: It is good practice to program the output to zero volts prior to sending the CLS command. This is especially important when output is above 130VAC or is system ground is noisy. Open Output Disconnect Relay String format: OPN Note: It is good practice to program the output to zero volts prior to sending the OPN command. This is especially important when output is above 130VAC or is system ground is noisy.
9
PAS 9732/AI ENGINEERING SPECIFICATION
Document PAS010 Revision C 8/27/03 PAS 9732/AI ENGINEERING SPECIFICATION 8 CHANNEL, 14 BIT, 3 MHz per CHANNEL VME ANALOG INPUT CARD Revision A (11/18/2000) Additional copies of this manual or other Precision
More informationGE Fanuc IC694ALG221. Rx3i PacSystem
GE Fanuc IC694ALG221 http://www.pdfsupply.com/automation/ge-fanuc/rx3i-pacsystem/ic694alg221 Rx3i PacSystem Input module, analog 4 point current. IC694A IC694AL IC694ALG 919-535-3180 sales@pdfsupply.com
More informationAirTest Model CN9000 Series Sensor Controller
AirTest Model CN9000 Series Sensor Controller AirTest Model CN9000 Series Sensor Controller THEORY OF OPERATION A basic CN9000 configuration consists of Input/Process/Display combination modules, a 3 relay
More informationOperating Instructions
CHEMICAL DRAINAGE SYSTEMS Fusion Lock Welding Unit Operating Instructions Table of Contents Specifications...................................................... 4 Important!.........................................................
More informationDCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies
DCS-E 1kW Series, DLM-E 3kW & 4kW Power Supplies M51A Option: Isolated Analog Programming Manual Power Supplies Elgar Electronics Corporation 9250 Brown Deer Road San Diego, CA 92121-2294 1-800-73ELGAR
More informationEMCP 4.4 Simulator Manual. Author: Lucas Tolbert CIC Engineering 345 Center Street East Peoria, IL
EMCP 4.4 Simulator Manual Author: Lucas Tolbert CIC Engineering 345 Center Street East Peoria, IL Date of Origin: 11/23/2010 Overview This document will detail the features and operation of the EMCP 4.4
More informationBOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.
QUICK START GUIDE I INTRODUCTION KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY 1.1. SCOPE OF MANUAL. This Quick Start Guide covers simple installation and local operation of the Kepco 100W,
More information80W (16V/5A) Power Supply with USB Output. User Manual
Test Equipment Depot - 800.517.8431-99 Washington Street Melrose, MA 02176 TestEquipmentDepot.com 1325 80W (16V/5A) Power Supply with USB Output User Manual 1325 Volt. C.V. Amp. C.C. V OUTPUT ON/OFF A
More informationNTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY
NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY USER MANUAL Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct
More informationBIPOLAR OPERATIONAL POWER SUPPLY
QUICK START GUIDE I INTRODUCTION KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY 1.1. SCOPE OF MANUAL. This Quick Start Guide covers simple installation and local operation of the Kepco 100W,
More informationBOP QUICK START GUIDE 100W, 200W, 400W. KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY I INTRODUCTION
QUICK START GUIDE I INTRODUCTION KEPCO An ISO 9001 Company. BIPOLAR OPERATIONAL POWER SUPPLY 1.1. SCOPE OF MANUAL. This Quick Start Guide covers simple installation and local operation of the Kepco 100W,
More informationInstallation & Operation
LED Readout Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon
More informationMultifunction Calibrator
Multifunction Calibrator Model CL TC - - - C V _ TECPEL CO., LTD. Features:. - (KΩ load, V Loop Supply). -.,-.V, -.V. K, J, E, T Thermocouple ( C and ). Frequency -.. Basic Accuracy. Easy Key-pad Operation.
More informationPACSystems* RX3i IC694ALG233
November 2015 PACSystems* RX3i IC694ALG233 Advanced Diagnostics Analog Current Input Module 16 Channel The PACSystems* RX3i 16-Channel Analog Current Input module provides 16 single-ended input channels.
More informationReference. Menu Overview. Functions Common to Generator (TX) and Analyzer (RX) AC Power. Selecting 115 VAC or 230 VAC Operation
Menu Overview A wide range of "auxiliary" setup functions is provided in the GB1400 Generator and Analyzer Menu systems. To enter the Generator or Analyzer Menu system, simply press the instrument's F1
More informationProtection System Simulator SIM600. Installation Manual
Protection System Simulator SIM600 1MRS756102 Issued: 08.12.2008 Version: B Protection System Simulator SIM600 Contents: 1. About this manual... 5 1.1. Copyrights... 5 1.2. Trademarks... 5 1.3. Guarantee...
More informationPower Supply (48Vdc, 2.5A)
Telecommunications Group Section 855-180-201 Equipment Issue 1 Fourth Printing, September 2006 8551-80 Power Supply (48Vdc, 2.5A) Compliant with UL Standard 60950, Second Edition* CONTENTS PAGE Part 1.
More informationModel 815 User s Manual
Model 815 User s Manual CAUTION Risk of electrical shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Weigh-Tronix reserves the right to change
More informationAgilent 66000A 1200 W DC Modular Power System, GPIB
Agilent 66000A 1200 W DC Modular Power System, GPIB Data Sheet Speed and accuracy for test optimization 8-slot mainframe accepts up to 8 DC power modules 1200 W total DC power output, up to 150 W per module
More informationCM78N C-01 Operating Manual CONFIGURING INSTRUCTIONS
CM78N TWO-PRESET PROGRAMMABLE ELECTRONIC COUNTER SOFTWARE C-01 CONFIGURING INSTRUCTIONS The instrument can be set up y the user to fit to different operating ways. There are three different basic configurations
More informationHypot III. Graphic Liquid Crystal Display. 10 Memories with 3 Steps per Memory. Low Limit Detection System. SmartGFI Circuit (Patent Pending)
Hypot III DIELECTRIC WITHSTAND TESTERS For Production Line Safety Agency Compliance Testing Graphic Liquid Crystal Display 10 Memories with 3 Steps per Memory Low Limit Detection System 3605 AC Hipot SmartGFI
More information15P0102Q2 SINUS PENTA KEYPAD CONNECTED TO NETWORK RS485 USERS MANUAL
15P0102Q2 SINUS PENTA KEYPAD CONNECTED TO NETWORK RS485 Upd. 08/06/04 R. 00 English This manual is integrant and essential to the product. Carefully read the instructions contained herein as they provide
More informationNEUROLOGIC RESEARCH CORPORATION MODEL 2500
NEUROLOGIC RESEARCH CORPORATION MODEL 2500 NETWORK HUMISTAT Compact, self-contained dehumidifier controller. 0.5 degrees C accuracy typical. RH sensor is digitally calibrated for 2% accuracy. Open communication
More informationINSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH
Instr. No. 2650-887C INSTALLATION INSTRUCTIONS 5" SINGLE CHANNEL ULTIMATE TACH MODEL 6871, 6872, 6873, 6874, 6875, 6877 IMPORTANT WEAR SAFETY GLASSES 5 4 6 COPYRIGHT PATENT PENDING 3 7 8 PLAYBACK 9 2 0
More informationRMS-U-RB-8 Relay box 8 User Manual
RMS-U-RB-8 Relay box 8 User Manual Version 1.1; 28.05.2014 2013 CONTEG, spol. s r.o. All rights reserved. No part of this publication may be used, reproduced, photocopied, transmitted or stored in any
More informationPlug & Play MCL488 FEATURES PRODUCT OVERVIEW MULTI-CHANNEL LOADS. Front Panel, Analog IEEE 488, or RS232 Control
MCL88 MULTI- LOADS Plug & Play FEATURES Front Panel, Analog IEEE 88, or RS232 Control 0 Amp, 350 Watt Modules 30 Amp, 75 Watt Modules Channels in 50V, 00V, 00V, or 00V Configurations Paralleling Channels
More informationSC100 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. (407) Phone: Website:
SC100 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: Website: (407) 299-3825 www.mpelectronics.com Operating Program Revision: 1 Revision Date: 4-2-18
More informationAnalog Current Input - 16 Channel IC693ALG223. Current Ranges. Power Requirements and LEDs. Location in System. Analog Input Modules
Analog Input Modules Analog Current Input - 16 Channel IC693ALG223 The 16-Channel Analog Current Input module provides up to 16 single-ended input channels, each capable of converting an analog input signal
More informationNTP-6621 / 6631 / 6661 SWITCHING MODE POWER SUPPLY with USB REMOTE CONTROL
NTP-6621 / 6631 / 6661 SWITCHING MODE POWER SUPPLY with USB REMOTE CONTROL USER MANUAL Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation
More informationThe 3 kw Models will accept 200*/230 VAC single phase and 200*/208 VAC three phase input power.
Sorensen DLM 3 & 4 kw Series DC Power Supply 3 4 kw 5 600 V 5 450 A 208 230 208 400 480 The Sorensen DLM 3kW and 4kW Series programmable DC power supplies are designed to provide highly stable, continuously
More informationELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL
ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL. 60101 www.electronicdisplays.com PRODUCT PART NUMBER : ED225MPC 2L N1-VERT-1001- KYN1 DESCRIPTION: Indoor 4 digit, 2.25 inch high, red LED, 2
More informationSensacell Troubleshooting Guide
A ONLY SOME MODULES LIGHT UP B PANEL DOES NOT LIGHT UP Only some modules light up Panel does not light up Check jumpers and power wiring AC Power present at Power Supply input terminals? Check AC Line
More informationPAD ANALOG / DIGITAL TRAINER OPERATOR S MANUAL
PAD - 234 ANALOG / DIGITAL TRAINER OPERATOR S MANUAL Rev. 7/94 GENERAL OPERATING PROCEDURES 1. This manual should be read thoroughly before engaging in any experimentation. 2. As a general rule, NEVER
More informationLAUREL. Laureate Digital Panel Meter for Process and Ratiometric Signals ELECTRONICS, INC. Features. Description
LAUREL ELECTRONICS, INC. Laureate Digital Panel Meter for Process and Ratiometric Signals Features Reads process signals from ±200 mv to ±600V or ±2 ma to ±5A full scale Ratiometric mode for bridges and
More informationIPM650 Intelligent Panel-Mount Display
Quick Start Guide IPM650 Intelligent Panel-Mount Display Sensor Solutions Source Load Torque Pressure Multi Component Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more
More informationCheckSum. FUNC-2B Functional Test Module. The FUNC-2B features:
CheckSum FUNC-2B Functional Test Module FUNC-2B Functional Test Module Made in U.S.A. The CheckSum Model FUNC-2B Functional Test System is designed to be used as an extension to a CheckSum ICT System.
More informationOPERATING INSTRUCTIONS for the CT Digital Circuit Breaker Analyzer
OPERATING INSTRUCTIONS for the CT-6500 Digital Circuit Breaker Analyzer Vanguard Instruments Company 1710 Grevillea Court Ontario, California 91761 TEL: (909) 923-9390 September 2003 FAX: (909) 923-9391
More informationDLRO 200 High Current, Low Resistance Ohmmeter
M DLRO 200 High Current, Low Resistance Ohmmeter USER MANUAL GSAFETY WARNINGS THESE SAFETY WARNINGS MUST BE READ AND UNDERSTOOD BEFORE THE INSTRUMENT IS USED. n DLRO200 is supplied without a plug terminating
More information405A Timer with Instantaneous Relay
< Marsh Bellofram Group of Companies < Automatic Timing & Controls < Timer < 405A Series Downloadable Files: 405A Series 405A Timer with Instantaneous Relay On-Delay version with instantaneous relay Selectable
More informationICS Regent. Guarded Analog Output Modules. 4 to 20 ma (T3480) PD-6026
ICS Regent PD-6026 Guarded Analog Output Modules 4 to 20 ma (T3480) Issue 1, March, 06 Guarded analog output modules provide 4 to 20 ma current outputs for a maximum of six user loads per module. These
More informationinstallation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE
POWER MONITORING INSTALLATION GUIDE H8030/8031 H8030/8031 Modbus Energy Meter Networked kw/kwh Transducer Product Identification Model Max Amps CT Size Enhanced Data Stream Meters H8030-0100- 100 H8030-0300-
More informationPACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223
May 2014 PACSystems* RX3i and Series 90*-30 IC694ALG223 and IC693ALG223 Analog Current Input Module 16 Channel The PACSystems* RX3i/Series 90* 16-Channel Analog Current Input module provides 16 single-ended
More informationKTD-125/ KTD-125P/125P-24 KTD-127/127W PTZ Receivers
KTD-125/125-24 KTD-125P/125P-24 KTD-127/127W PTZ Receivers 2003 Kalatel, a GE Interlogix company All Rights Reserved. Any GE Interlogix, Kalatel division, software supplied with GE Interlogix, Kalatel
More informationTABLE OF CONTENTS ARC DATA MONITOR III, PORTABLE MODEL D OPERATIONS MANUAL 09/03/97
TABLE OF CONTENTS ARC DATA MONITOR III, PORTABLE MODEL D OPERATIONS MANUAL 09/03/97 SECTION 1 - INTRODUCTION 1.0 Overview...1 1.1 ADM Sensors and Output Functions...2 1.2 Operational Modes...2 1.3 User-Defined
More informationFEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)
COUNTERS for IMPULSES Series MAG983-X COUNTERS for IMPULSE signals FEMA ELECTRÓNICA MAG983-1 MAG983-2 MAG983-3 MAG983-4 IDEAL SOLUTION for impulse counting applications where the operator has no access
More informationIgnitron Driver Manual (N = cable length in meters -example IG5F2-10 = unit with a 10 meter cable length)
North Star High Voltage 12604 N New Reflection Dr, Marana, AZ 85653 520 780 9030; (206)219-4205 FAX www.highvoltageprobes.com DANGER - Voltages of up to 2.5 kv are generated by this unit Ignitron circuits
More informationAPEX Junior Cased Weighing Indicator/Controller
APEX Junior Cased Weighing Indicator/Controller Non-Trade User Manual www.pcm-uk.com APPROVED DISTRIBUTORS OF: Electronic Weighing Services 1 Index Section 1: Setting Up (Terminations and time/date routines)
More information750/760 Feeder Management Relay Instruction Manual
GE Digital Energy 750/760 Feeder Management Relay Instruction Manual Software Revision: 7.4x Manual P/N: 1601-0120-AK Manual Order Code: GEK-106471T GE Digital Energy 650 Markland Street Markham, Ontario
More informationI. PANEL DESCRIPTION... 1
Table of Contents I. PANEL DESCRIPTION... 1 II. OPERATING INSTRUCTION... 7 1. MA OUTPUT... 7 1A. GENERAL OPERATION 4-20MA... 7 1B. SELECT 0-20MA OR 0-24MA... 8 1C. ENTER A VALUE LESS THAN 1... 9 2. % (PERCENTAGE)
More informationIS31LT3918 T8 Lighting Evaluation Board Guide
Description Quick Start The IS31LT3918 LED driver IC is a peak current detection buck converter which operates in constant off time mode. It operates over a very wide input voltage supply range of 6VDC
More informationBTU-4D/BTU-4D-I Digital Temperature Unit & Sensors. Installation and Operation Manual
BTU-4D/BTU-4D-I Digital Temperature Unit & Sensors Installation and Operation Manual BTU-4D/BTU-4D-I Installation and Operation Manual Rev E Table of Contents Introduction... 1 TEMP OUTDOOR Sensor... 1
More informationMAINTENANCE MANUAL KTS 153 TEST SET
MAINTENANCE MANUAL KTS 153 TEST SET MANUAL NUMBER 006-15631-0007 REVISION 7 FEBRUARY, 2002 WARNING Prior to the export of this document, review for export license requirement is needed. COPYRIGHT NOTICE
More informationIPS INTELLIGENT PUMP STARTER
IPS INTELLIGENT PUMP STARTER The IPS Intelligent Pump Starter features SMARTSTART motor protection, integrated electronic pump protection overload, and power metering and data logging options. Ø & Ø, 0/60
More informationDIGITAL PANEL METERS
DIGITAL PANEL METERS 3 1/2 digit,4 1/2 digit - A/C D/C Voltage/Current 3 1/2 digit4 1/2 digit- AC/DCVoltage/Current-TRMS DPM U AC/DC VOLTAGE / CURRENT 3 1/2 DIGIT - MODEL : PE 3000 4 1/2 DIGIT - MODEL
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationModel OI x22 ProSafe
Model OI-7420 4x22 ProSafe Operation Manual Revision 2.0w Product Overview The Otis Instruments, Inc. GenII ProSafe 4x22 Model OI-7420 is a two channel gas monitor that functions as a transmission controller.
More informationInnovative Electronics for a Changing World. Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring
Innovative Electronics for a Changing World Charge Smart R1 MPPT 12V/24V Auto detect Mains and Solar Battery charger with Remote Network Monitoring INDEX 1. SYSTEM DESCRIPTION 2. SYSTEM WIRING 3. SYSTEM
More informationOpal Pro AB Ethernet IP. Opal Pro MS6 SERIES. AB Ethernet IP Interface Users Manual. Revision Page 1
Opal Pro MS6 SERIES AB Ethernet IP Interface Users Manual Revision 1.02 Page 1 Page 2 FOR YOUR SAFETY Only qualified personnel should install this equipment, after first reading and understanding all the
More informationInstallation & Operation Guide
Installation & Operation Guide (Shown with optional Override Board Cover) KMD-5831 Programmable Loop Controller PLC-28 Direct Digital Controller 902-019-04B 1 Introduction This section provides a brief
More informationAgilent 84904, 6, 7K/L Programmable Step Attenuators
Agilent 84904, 6, 7K/L Programmable Step Attenuators Data Sheet High Accuracy,Excellent Reliability, Long Life Features and description DC to 26.5 GHz, DC to 40 GHz frequency coverage Optional calibration
More informationKNOCK METER from Insane Import Performance (c) Leonard R White 2014 DOWNLOAD GUI INSANE IMPORT PERFORMANCE CONNECTIONS. If yours was sent assembled
KNOCK METER from Insane Import Performance (c) Leonard R White 2014 DOWNLOAD GUI INSANE IMPORT PERFORMANCE CONNECTIONS If yours was sent assembled Red = 12v switched ignition on Black = Ground/shielding/sensor
More informationEM271 COMMUNICATION PROTOCOL. Version 0 Revision 0
EM271 COMMUNICATION PROTOCOL Version 0 Revision 0 May 12 th, 2014 Index 1.1 Introduction... 3 1.2 MODBUS functions... 3 1.2.1 Function 03h (Read Holding Registers)... 3 1.2.2 Function 04h (Read Input Registers)...
More informationNo actual trip output occurs if the upper paddle is removed first.
BE1-27/59 SCOPE This test procedure covers the testing of the Basler BE1-27/59 under/overvoltage relay. Refer to IM 9170600990 Rev. L (12/12) for testing support information and component level identification.
More informationEM24-DIN PFA, PFB & X models
EM24-DIN PFA, PFB & X models COMMUNICATION PROTOCOL Version 4 Revision 0 December 03 th, 2012 Index 1.1 Introduction...3 1.2 MODBUS functions...3 1.2.1 Function 03h (Read Holding Registers)...3 1.2.2 Function
More informationPACSystems* RX3i IC694ALG232
November 2015 PACSystems* RX3i IC694ALG232 Advanced Diagnostics 16 Channel Input Analog Voltage Module The PACSystems* RX3i 16-Channel Analog Voltage Input module provides 16 single-ended or 8 differential
More informationEZCT-2KA. current transformer test set
EZCT-2KA current transformer test set EZCT-2KA current transformer test set Product Overview The EZCT-2KA is Vanguard s third-generation microprocessor-based current transformer test set. The EZCT-2KA
More informationVariable Frequency Drive Design Guidelines
Variable Frequency Drive Design Guidelines The Variable Frequency Drive Design Standard provides design criteria and specifications used in the procurement and application of variable frequency drives
More informationQC-3265 Checkweigher User s Manual
QC-3265 Checkweigher User s Manual CAUTION Risk of electrical shock. Do not remove cover. No user serviceable parts inside. Refer servicing to qualified service personnel. Weigh-Tronix reserves the right
More informationCAN-Transceiver Data Register Map MODBUS Slave RTU
MODBUS Slave RTU V1.40 Table of Contents INTRODUCTION... 3 CAN TRANSCEIVER GLOBAL DATA... 3 OPTIONAL DIGITAL INPUTS... 3 AVC (TR CONTROL) REGISTER BASE ADDRESSES... 3 AVC MODBUS REGISTER DEFINITION...
More informationHI-POT TESTER. User s Manual
HI-POT TESTER 7620 User s Manual Contents 1. Before Use... 1.1Electric Shock Avoidance... 4 1.2 Grounding... 4 1.3 AC Power Supply... 4 1.4 Connecting Test Leads... 4 1.5 Warm Up... 4 1.6 External Control...
More informationSeven Channel Remote Control
Seven Channel Remote Control Page 1 Versa7 Kit Contents The Versa7 is designed to remotely control up to seven devices, or functions. All seven functions can be controlled with the supplied four button
More informationINSTALLATION INSTRUCTIONS
TT-568 /a INSTALLATION INSTRUCTIONS Original Issue Date: 2/ Model: 4/20RES and 4/20RESL Generator Sets Market: Residential/Commercial Subject: RDC and DC Controller Replacement Kits GM79884 and GM79885
More informationADDENDUM FOR 20, 27, & 28 OPTIONS
ADDENDUM FOR 20, OPTIONS GENERAL The 20, 27, and 28 option provides for an alarm contact OR an AC transfer switch on EXELTECH XP Series inverters. The alarm relay monitors the inverter s AC output and
More informationCL-12 Linear Fader Controller for the 688. User Guide
CL-12 Linear Fader Controller for the 688 User Guide Legal Notices Product specifications and features are subject to change without prior notification. Copyright 2015 Sound Devices, C. All rights reserved.
More informationGV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000
GV3000/SE Operator Interface Module (OIM) User Guide Version 2.0 M/N 2RK3000 Instruction Manual D2-3342-2 The information in this manual is subject to change without notice. Throughout this manual, the
More informationOwner s Manual Revision 4.01 Option 1
Owner s Manual Revision 4.01 Option 1 Special Version of the SW series Inverter / Charger for Motor Coach Applications Part # 2031-7 (Supplement to Normal Manual) Effective Date: April 17, 1996 Trace Engineering
More informationLAUREL. Laureate Digital Panel Meter for Load Cell & Microvolt Input ELECTRONICS, INC. Features. Description
Description LAUREL ELECTRONICS, INC. Features Laureate Digital Panel Meter for Load Cell & Microvolt Input 20, 50, 100, 250 & 500 mv ranges Span adjust from 0 to ±99,999, zero adjust from -99,999 to +99,999
More informationXT-9100 Configuration Guide
System 9100 Technical Manual 636.4 Configuration Guides Section Configuration Guide Issue Date 0896 XT-9100 Configuration Guide XT-9100 Extension Module/XP-910x Expansion Modules Page 3 Introduction 3
More informationEM270 COMMUNICATION PROTOCOL. Version 1 Revision 0
EM270 COMMUNICATION PROTOCOL Version 1 Revision 0 October 4 th, 2013 Index 1.1 Introduction... 3 1.2 MODBUS functions... 3 1.2.1 Function 03h (Read Holding Registers)... 3 1.2.2 Function 04h (Read Input
More informationSC168MBM 16x8 Characters MODBUS MASTER LCD
Product Description SC168MBM is a programmable LCD that serve as MASTER RTU MODBUS device. It reads and display registers values from MODBUS Slave devices through its RS485 port. The LCD can be configured
More informationJANUARY 2000 TS800A TS801. MicroScanner
JANUARY 2000 TS800A TS801 MicroScanner CUSTOMER SUPPORT INFORMATION Order toll-free in the U.S.: Call 877-877-BBOX (outside U.S. call 724-746-5500) FREE technical support 24 hours a day, 7 days a week:
More informationElectric Actuators and Control Systems. Established Leaders in Valve Actuation AD Instruction Manual. Publication P972E Issue 08/09
Electric Actuators and Control Systems Established Leaders in Valve Actuation AD-9120 Instruction Manual Publication P972E Issue 08/09 Instruction Manual IM-0626 AD-9120 Digital Servo Amplifier Table of
More information1-1 AC DRIVE OVERVIEW EXERCISE OBJECTIVE
1-1 EXERCISE OBJECTIVE Familiarize yourself with the AC Drive. Read AC Drive parameter settings. Set the basic AC Drive parameters to control the Four-Pole Squirrel-Cage Induction Motor. DISCUSSION Figure
More information.2 Section General Commissioning (Cx) Requirements. .3 Section Common Work Requirements - Electrical
Issued for Review Section 26 28 16.01 Air Circuit Breakers Page 1 of 7 PART 1 GENERAL 1.1 GENERAL.1 This specification serves to define requirements for a replacement of low voltage circuit breaker of
More informationModel OI x42 ProSafe
Model OI-7440 4x42 ProSafe Operation Manual Revision 2.2w Product Overview The Otis Instruments, Inc. GenII ProSafe 4x42 Model OI-7440 is a four channel gas monitor that functions as a transmission controller.
More informationInductive and Capacitive Proximity Sensors Identification Codes. Product Type/Size Output Type of Sensing Options Group of Housing Output Distance
Proximity Sensors Inductive Sensors Inductive Proximity Sensors are used when the target or object to be sensed is metal. Inductive types are the most widely used proximity sensors for industrial applications.
More informationChronomax Time Switch
Naztec Operations Manual For Chronomax Time Switch Version 1.x/2.x/3.x April 2003 Published by: Naztec, Inc. 820 Park Two Drive Sugar Land, Texas 77478 Phone: (281) 240-7233 Fax: (281) 240-7238 Copyright
More informationElectronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features
Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter
More informationPMDX-108-Output. 8-Channel Isolated Output Board for PC parallel port pins 2-9. User s Manual
PMDX-108-Output 8-Channel Isolated Output Board for PC parallel port pins 2-9 User s Manual Date: 25 February 2010 PMDX Web: http://www.pmdx.com 9704-D Gunston Cove Rd Phone: +1 (703) 372-2975 Lorton,
More informationELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL
ELECTRONIC DISPLAYS INC. 135 S. CHURCH STREET ADDISON, ILL. 60101 www.electronicdisplays.com ED206/406-115 4D N1 - KY DESCRIPTION: 2.25 in. or 4.0 in. high, red 7 segment display; Programmable up/downtimer
More informationCantata m100 Amplifier
Cantata m100 Amplifier Getting Started Guide www.resolutionaudio.com +1.415.553.4100 Safety Information CAUTION RISK OF ELECTRICAL SHOCK DO NOT OPEN CAUTION: TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO
More informationInstruction Manual for BE-SP3 Circuit. 10/21/07
Page 1 of 54 Instruction Manual for BE-SP3 Circuit. 10/21/07 Page 1 Index: Page 2 BE-SP3 Circuit Specifications. Page 3-4 Intro to the BE-SP3. Page 5 Basics of serial to parallel. Page 6-7 ASCII Code.
More informationNETRONICS HS3500 CONTROLLER
NETRONICS HS3500 CONTROLLER CUSTOMER NAME CONTROLLER SERIAL # CONTROLLER PART # PERSONALITY SWITCH SETTINGS BULLET PRESS CONFIGURATION DELIVERY DATE Contact the factory for help setting up your application.
More informationDescription of Optional MEMORY AND TIME DELAY P-C BOARD. Part Number
TO-210 121090 Revised Description of Optional MEMORY AND TIME DELAY P-C BOARD Part Number 282308 HOBART BROTHERS COMPANY Airport Systems Group Troy, Ohio 45373 U.S.A. This page intentionally left blank.
More informationTABLE I RANGE, POWER, OUTPUT (CONDUCTIVITY MEASUREMENTS)
Issue 11 Page 1 of 5 Model Selection Guide Instructions Consult Steps to Selecting Appropriate Conductivity Instrumentation and Cells before making selections below. Select the desired key number. The
More informationINSTRUCTION MANUAL. for. Kit, Variable Frequency and Voltage. for use with. Hobart Series A. 180 kva PoWerMaster Converter
TO-314 Original 050506 Revision 1 012611 INSTRUCTION MANUAL for Kit, Variable Frequency and Voltage for use with Hobart Series 500049A 180 kva PoWerMaster Converter Hobart Ground Power Troy, Ohio 45373
More informationGNM3D Series COMMUNICATION PROTOCOL. Version 1 Revision 0
GNM3D Series COMMUNICATION PROTOCOL Version 1 Revision 0 Index 1.1 1.2 Introduction... 3 MODBUS functions... 3 1.2.1 Function 03h (Read Holding Registers)... 3 1.2.2 Function 04h (Read Input Registers)...
More informationRS3000 SERIES BILL ACCEPTORS
Flash Diagnostic Codes RS3000 SERIES BILL ACCEPTORS INSTALLATION GUIDE s of the bill acceptor. Below is a chart that lists all the flash codes of the RS3000 Bill Acceptor and a description of each code.
More informationATE-DMG QUICK START GUIDE. KEPCO An ISO 9001 Company. VOLTAGE/CURRENT STABILIZED POWER SUPPLY WARNINGS I INTRODUCTION II SAFETY.
QUICK START GUIDE KEPCO An ISO 9001 Company. ATE-DMG VOLTAGE/CURRENT STABILIZED POWER SUPPLY I INTRODUCTION 1.1. SCOPE OF MANUAL. This Quick Start Guide covers simple installation and local operation of
More information