1 CM78N TWO-PRESET PROGRAMMABLE ELECTRONIC COUNTER SOFTWARE C-01 CONFIGURING INSTRUCTIONS The instrument can be set up y the user to fit to different operating ways. There are three different basic configurations available: Up/down counter with settable cycle Partial/total counter with settable cycle counter with settable cycle Each basic configuration has settable operating modes. BASIC CONFIGURATIONS The choice of the basic configurations is performed as follows: Press the key F and as the display shows Ch.Set. digit the key sequence R Arrow 2 Arrow 4 (the sequence must be entered within 5 seconds). The display will show: Configuration Count type Input polarity Decimal digits F.XXXX Arrow key 1 Press the arrow key corresponding to the mode to be set until you reach the number corresponding to the required function. Find hereunder the list of functions and corresponding numbers: Configuration Up/Down counter with settable cycle 0 Partial/Total counter with settable cycle 1 counter with settable cycle 2 Count type Bidirectional x 4 0 Bidirectional x 1 1 Monodirecal on the falling edge 2 Monodirectional on the rising edge 3 Monodirectional with multiplication x 2 4 Functional inputs polarity NPN 0 PNP 1 Decimal digits No one 0 One decimal 1 Two decimals 2 Three Decimals 3 After the settings press the key F to confirm and switch to setting the speficic operating modes, according to the chosen basic configuration. 1 /7
2 SPECIFIC SETTINGS This phase is accessed by pressing the key F and, as the display shows Ch.Set the key sequence Arrow 1, Arrow 6, Arrow 2. The setting is made by pressing the arrow key corresponding to the mode to be set until you reach the number corresponding to the required function. The following three cases may occur, according to the choice made for the basic configuration. Chosen configuration: Up/Down Counter with settable cycle Reset Mode(IN 1) On the state 0 c. XXX On the front 1 Reset Mode Count Mode Single with steady outputs 0 Single with pulse outputs 1 Repeating with steady output 1 and pulse output 2 2 Repeating with pulse outputs 3 Chosen configuration: Partial/Total Counter with settable cycle c. XXX Preselections mode Dividing fact.for total Chosen configuration: Counter with settable cycle c. XXXX s counter s no.set Deceleration set Count Mode Up-counter 0 Down-counter 1 Single with steady outputs 0 Single with pulse outputs 1 Repeating with steady output 1 and pulse output 2 2 Repeating with pulse outputs 3 Preselections Mode 2 on partial count 0 1on partial count, 1 on deceleration value 1 1 on partial count, 1 on total count 2 Dividing Factor on Total Count Dividing factor x 1 0 Dividing factor x 10 1 Dividing factor x Dividing factor x Counter Inside 0 External 1 Number Set Free 0 Under constants key 1 Deceleration Set Free 0 Under constants key 1 Single with steady outputs 0 Single with pulse outputs 1 Repeating with steady output 1 and pulse output 2 2 Repeating with pulse outputs 3 2 /7
3 INSTALLATION INSTRUCTIONS TECHNICAL SPECIFICATIONS SUPPLY 230 or 115 or 24 Vac 50/60 Hz ±10% -4 VA, 24Vdc* o 12 Vdc* ±15% 4 W (see the instrument label). *Remark: the supply negative pole (terminal 1) is connected to circuit 0 Volt (terminal 8). TRANSDUCER SUPPLY 12 Vdc max 60 ma, 5Vdc 60 ma optional (code X09) FUNCTIONAL INPUTS: accepting signals by NPN/PNP transducers INPUTS: closing T.min = 20 ms OUTPUTS: Outputs are on relay with Normally Open contacts. I max 3A V max 220V COUNT FREQUENCY: 25 KHz (primary wave) MEMORY: Data, preselections and count record are stored on EEPROM. COUNT INPUT SIGNALS The instrument accepts count signals by: Monodirectional encoders with NPN open collector or push-pull output Bidirectional encoders with NPN open collector or push-pull output 1 Namur inductor with NPN open collector or push-pull output 2 Namur inductors with NPN open collector or push-pull output 90 degree out of phase CONNECTION Link connections to the quick-coupling terminal box as mentioned in the enclosed diagram C2614. REMARK To avoid damaging interference, it is recommended, as for all low voltage equipment, to use a shielded cable for the execution of connections and to separate the signal cable path of the counter from possible connection cables of power utilities. MAINTENANCE Counters do not require any particular maintenance. Keys shall not be pressed with sharp objects to avoid damaging of the keyboard. OPERATING INSTRUCTIONS After choosing the basic configuration and the specific settings (see par. 1 and 2 of the present manual) you can enter the operating parameters, named constants. CONSTANTS SET The constants menu is accessed by pressing the key F and, when the display shows ch.set. the constants key P2 F P1. The different constants are displayed in sequence: use the arrow keys to modify the values and the key F to confirm your choice and switch to the following parameter. The key R sets the constant value to zero. Factor It is the multiplying factor of the input pulses and ranges between 0.01 and The display shows FAtt. followed by the current value. Use the arrow keys to modify the value (the key R sets to zero) and F to confirm. Load It is the value entered in the count record in case of reset by keyboard or by input. The display shows LoAd followed by the current value. Output 1 Time It is the time output 1 remains on, expressed in seconds. The minimum setting is 0.1 sec, the max. setting is 25.0 sec. (default 0.3 sec.). The parameter is only shown if the option time output 1 was enabled in the modes set. The display identification is tout 1. 3 /7
4 Output 2 Time It is the time output 2 remains on, expressed in seconds. The minimum setting is 0.1 sec, the max. setting is 25.0 sec. (default 0.3 sec.). The parameter is only shown if the option time output 2 was enabled in the modes set. The display identification is tout 2. s Number The parameter is only shown in case it was chosen the basic configuration counter and the option settable cycle was enabled in the modes set. The display identification is n.cicli. Deceleration The parameter is only shown in case it was chosen the basic configuration counter and the option deceleration was enabled in the modes set. The display identification is rall. OPERATING WAY BASIC CONFIGURATION 0: Up/Down Counter With Settable Preselections set: 1- Up-counter: Press -P1- to access the first preselection setting phase Press P2- to access the second preselection setting phase. A flashing dot appears on the display right side during the phase. Press -P1- to leave the first preselection setting phase. Press P2- to leave the second preselection setting phase. 2-Down-counter: Press P1 to access the LOAD value (measure) setting phase. Press P2 to access the DECELERATION setting phase. A flashing dot appears on the display right side during the phase. Press -P1- to leave the LOAD setting phase. Press P2- to leave the DECELERATION setting phase. REPEATED CYCLE 1-Up-Counter: At reaching of the second preselection the relay OUT2 gets excited for the set time and the count is reset at the same time. Since the count is reset in 0.5 ms it is advisable to adjust the machine speed so that the count frequency is equal or less than 1 KHz after the first preset reaching (deceleration) in order to avoid count errors. The count reset always takes place in correspondance with the second preselection: therefore if you use one single preselection it is necessary to use the second one. 2-Down-Counter: At reaching of the zero value the relay OUT 2 gets excited for the set time and at the same time the LOAD value is entered in the count record. The LOAD value is entered in 0.5 ms, therefore it is advisable to adjust the machine speed so that the count frequency is equal or less than 1 KHz after the first preset reaching (deceleration) in order to avoid count errors. LOAD BY KEYBOARD Pressing the key R the display shows the flashing message LOAD. Press the key R again to reset or enter the load value or the key F to switch to the count display with no modifications. INPUTS/OUTPUTS The instrument is equipped with two inputs, IN 1 = load/reset and IN2 = count block, and with two relay outputs with normally open contacts; in case of up-counter the contacts close at reaching of the relevant preselections; in case of down-counter they close at reaching of the deceleration value (OUT 1) and zero (OUT 2). 4 /7
5 BASIC CONFIGURATION 1: Partial/Total Counter With Settable Preselections set: Preselection Mode 2 Partial counter: Press -P1- to access the first preselection setting phase Press P2- to access the second preselection setting phase. A flashing dot appears on the display right side during the phase. Press -P1- to leave the first preselection setting phase. Press P2- to leave the second preselection setting phase. Preselection Mode: 1 DECELERATION + 1 PRESET ON PARTIAL COUNT P1 is the deceleration value, P2 is the preselection value. Operation example: -P1(deceleration) = 10 P2(preselection) = 100 The relay OUT 1 gets excited at 90 (preselection deceleration) and relay OUT 2 gets excited at 100 (preselection). Preselection Mode: 1 preselection on partial count + 1 PRESET ON total count -P1- is the preset on partial count, -P2- is the preset on total count. REPEATED CYCLE WITH PRESELECTIONS ON THE PARTIAL COUNT ONLY At reaching of the second preselection the relay OUT2 gets excited for the set time and the count is reset at the same time. The count reset always takes place in correspondance with the second preselection: therefore if you use one single preselection it is necessary to use the second one. REPEATED CYCLE WITH ONE PRESELECTION ON PARTIAL COUNTER AND ONE PRESELECTION ON TOTAL COUNTER Operating cycle: Timed OUT 2 Steady OUT 1 Partial count: At reaching of preselection P1 the relay OUT2 gets excited for the set time and the partial count is reset at the same time Total count: At reaching of the second preselection P2 the relay OUT1 gets excited and it remain excited until the total counter is reset. REPEATED OPERATING CYCLE WITH TIME OUTPUTS REPEATING OPERATING CYCLE TIME OUTPUTS Partial count: At reaching of preselection P1 the relay OUT1 gets excited for the set time and the partial count is reset at the same time Total count: At reaching of the second preselection P2 the relay OUT2 gets excited and the total count is reset at the same time. REMARK FOR THE REPEATED CYCLE: The count is reset in 0.5 ms, therefore it is advisable to adjust the machine speed so that the count frequency is equal or less than 1 KHz after the first preset reaching (deceleration) in order to avoid count errors. CHOICE OF THE DISPLAY MODE To switch from tne PARTIAL COUNT display to the TOTAL COUNT display press the key R or agendo on input IN2. During the total count display a dot lights on the first display on the left. INPUTS/OUTPUTS The inputs IN1 IN2 IN3 are enabled by the input signal edge. IN1 Resets the displayed value IN2 Partial/total display switch IN3 Total count reset With reference to the preselection mode, outputs are: Mode 0: OUT1= Presel.1 OUT2=Presel2 Mode 1: OUT1= Decel. OUT2= Presel. Mode 2: OUT1= Total OUT2= Partial 5 /7
6 BASIC CONFIGURATION 2: Counter with cycle counter and settable cycle Preselection and deceleration set: If the option was enabled in the modes set, pressing -P1- gives access to the deceleration value setting phase Press P2- to access the preselection setting phase. A flashing dot appears on the display right side during the phase. Press -P1- to leave the deceleration setting phase. Press P2- to leave the preselection setting phase. REMARK: The preselection value is only selectable in the positive field CYCLES NUMBER SET If the option was enabled in the modes set, pressing -F1- gives access to the cycles number setting phase Press -F- again to leave the phase. REMARK: The cycle counter can be disabled by setting 0 as value. CHOICE OF THE DISPLAY MODE To switch from tne COUNT display to the CYCLES COUNTER display (and vice-versa) press the key R. During the cycles counter display a dot lights on the display left side. COUNT RESET/CYCLES COUNTER The count is reset on input IN1 edge. The cycles counter is reset on input IN3 edge. EXTERNAL CYCLES COUNTER In case an external cycles counter is implemented, the cycles counter is increased on input IN2 edge. OUTPUTS OUT 1 = Deceleration + s end, OUT 2 = Stop Single cycles steady outputs inside cycles counter external cycles counter Decel. Stop Count. Count. s Cont. s Reset Reset Reset Count Reset Reset Single or repeated cycle pulse outputs Rall. Stop For repeating cycle the count s s reset is automatic Reset Count Reset Repeating cycle Steady out 1 Pulse out 2 Decel.. Stop s Reset Count Reset 6 /7
7 CM78N TEST PHASE CM78N main functions may be tested as follows: Press the key F6 until the instrument enters the test phase The display shows: test DISPLAY, OUTPUTS AND KEYBOARD TEST Keys functions is as follows, during this phase: The key F enables/disables the display test The arrow keys F1 F6 lighten\switch off the relevant decimal points.. t.e.s.t. P1 enables/disables the relay corresponding to output 1 and signals it on the display P2 enables/disables the relay corresponding to output 2 and signals it on the display o o test Output 1 Output 2 INPUTS TEST Closing the inputs on the terminal box is signalled by the enlightment of the relevant segments on the display: IN3 IN2 IN1 test TESTING END The relay corresponding to output 1 and signals it on the display R when the display shows test to leave the phase and switch to the instrument normal operating way. Via Vittorio Veneto, 4 I CORSICO (MI) Tel Fax info@elap.it 7 /7
8
PANEL DIGITAL READOUT ABSOLUTE/RELATIVE DISPLAY INPUT BY POTENTIOMETER 2 RELAY OUTPUTS
VD4 LQ2R PANEL DIGITAL READOUT ABSOLUTE/RELATIVE DISPLAY INPUT BY POTENTIOMETER 2 RELAY OUTPUTS Digital readouts series VD4 LQ can be coupled to linear and rotary potentiometers with resistive value ranging
More informationPanel Indicators. NEW 4~20mA Panel Display. Process Indicators INTECH INSTRUMENTS.
The LPI-LCD-6-4~20mA panel display is ideal for displaying a variety of process variables, and is easy to scale to your required engineering units. LPI-LCD-6 4~20mA Panel Display. Loop powered. Loop powered
More informationElectronic Preset Counter with 2 Presets and Print interface. NE213 Prog Features
Electronic Preset Counter with 2 Presets and Print interface NE21 Prog. 09 Features Order designation Order no. Interface RS22 Models Connection Functions LED-preset counter with 2 presets Batch counter
More information02/11/2015
48 x 48 Max. Counting Speed 5 KHZ Green backlit LCD display Part number 87629111 Counter, Preselection chronometer Maximum input frequency 5 k Hz Simple parameter setting, configuration using text menus
More informationFACTORY AUTOMATION. Manual Speed Monitor KFU8-DW-1.D
FACTORY AUTOMATION Manual Speed Monitor KFU8-DW-.D With regard to the supply of products, the current issue of the following document is applicable: The General Terms of Delivery for Products and Services
More informationAmplifiers, Counters, Timers & Controls
Amplifiers, Counters, Timers & Controls Panel Meter 814 Counter/Timer/Rate Indicator 815-817 Speed Monitor 818-819 Signal Converter 820-822 Power Supplies/Amplifier 823-824 813 Panel Meter Panel Meter
More informationsigno 727 SSI Operating Instructions Position-Indicator with/without limit values and SSI input from absolute encoder
Operating Instructions signo 727 SSI Position-Indicator with/without limit values and SSI input from absolute encoder Contents 1. Safety instructions 1 2. Mounting of the position indicator 2 2.1 Mounting
More informationUniversal counter UZ 9648 Counting - length measurement - metering - positioning
+49-(0)40-670 73-0 Fax +49-(0)40-670 73-288 info@martens-elektronik.de www.ghm-messtechnik.de Universal counter UZ 9648 Counting - length measurement - metering - positioning Features M LED-Display 14.2mm
More informationG60 SERIES ELECTRONIC PRESET COUNTER ESC P1 / P2 SHIFT RESET ENT
LINE SEIKI G0 SERIES ELECTRONIC P COUNTER or DIGITS ( Line LED Display) POWER SUPPLY (AC0 ~ 0V) PRESCALE FUNCTION KEY PROTECT, MEMORY DECIMAL POINT POSITIONING DUST / SPLASH PROOF G0 - G0 - MODEL SELECTION
More informationsigno 727 SSI operating instructions
operating instructions signo 727 SSI Position-Indicator with/without limit values and SSI input from absolute encoder 1. Safety instructions This instrument has been built and tested in accordance with
More informationFEMA ELECTRÓNICA. Series MAG983-X. COUNTERS for IMPULSE signals MAG983-1 MAG983-2 MAG983-3 MAG USER S MANUAL (HT0695-r050705)
COUNTERS for IMPULSES Series MAG983-X COUNTERS for IMPULSE signals FEMA ELECTRÓNICA MAG983-1 MAG983-2 MAG983-3 MAG983-4 IDEAL SOLUTION for impulse counting applications where the operator has no access
More informationDigital Frequency Divider INSTRUCTION MANUAL CONTENTS. 1. Working Principle Installation Setting Up Technical Data 4.
Digital Frequency Divider INSTRUCTION MANUAL CONTENTS 1. Working Principle 2 2. Installation 2 3. Setting Up 3 4. Technical Data 4 Code: 189/1a 1 WORKING PRINCIPLE The DFD has been designed to generate
More informationNF760 Batch Controller
NF760 Batch Controller Overview The NF760 Batch Controller is suited to flow applications where precise measurement and control of batch quantities is required. Batch total, flow rate, accumulated total
More informationTC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER
TC 34 MICROPROCESSOR-BASED DIGITAL ELECTRONIC COUNTER TECHNICAL DATA MECHANICAL DATA Housing Self-extinguishing plastic, UL 94 V0 Dimensions 33x75 mm depth 64 mm Weight 175 g approx. Connections 2,5 mm
More informationUsers Manual. TABLE OF CONTENTS 1 WORKING PRINCIPLE Operating limits Applications... 2
instrumentación para fluidos Digital frequency divider DFD-2 E Users Manual TABLE OF CONTENTS 1 WORKING PRINCIPLE... 2 1.1 Operating limits... 2 1.2 Applications... 2 2 INSTALLATION... 2 2.1 Mains connection...
More informationVeeder-Root brand Series C628 Rate Meter (C628-4XXX)
Introduction Your Veeder-Root brand C628 Rate Meter is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed to
More informationHardware Manual CNC760
Hardware Manual CNC760 Revision 3 6 December, 2017 Released Copyright 2017 by Eding CNC History: Revision Date Author 1 22-5-2017 AB 2 23-6-2017 AB 3 6-12-2017 AB Revision overview: Revision Remarks 1
More informationUser friendly and easy to program
New Product Digital Panel Meter WPMZ User friendly and easy to program μm m/min mm rpm m/min ton Universal design! New Digital Panel Meter Specification is subject to change without notice Watanabe Electric
More informationDisplays Transducers. Displays and transducers
JJ Displays JJ Transducers Displays and transducers DS_Displays_and_transducers 06/2016 225 Displays and transducers Our electronic devices for flow and volume measurement are suitable for all SIKA flow
More informationUltrasonic sensors Discrete output Analog output
Analog output General information Switch or analog outputs Sensing distances up to 6m Stainless steel housing Quick disconnect Index Discrete.... Analog....6 Technical data....8 AC 00 0/98 ULTRASONIC :
More informationGFC114. Low Power Flow Computer FEATURES
Low Power Flow Computer FEATURES l UNIVERSAL INPUT, 5 khz, CAN POWER THE l SIMPLIFIED MENUS AND PROGRAMMING l NO NEED OF AMPLIFIERS OR LINEARIZERS l SEVEN DIGIT RATE WITH PROGRAMMABLE DECIMAL PLACES l
More informationDIGITAL DISPLAY. for Industry Applications. Series WAY-SSI. Key-Features:
DIGITAL DISPLAY for Industry Applications Series WAY-SSI Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Description...4 Order Code & Accessories...6 - WAY-SSI-S:
More informationINSTALLATION MANUAL. LC 200 Electronic Overload Guard. Software versione PW0501 R 0.3
INSTALLATION MANUAL LC 200 Electronic Overload Guard Software versione PW0501 R 0.3 CONTENTS MAIN FEATURES LC 200 TECHNICAL FEATURES Page 2 SYMBOLS Page 3 WARNINGS Page 3 IDENTIFICATION DATA PLATE Page
More informationModular Panel Meter Series EDM 35
Modular Panel Meter Series EDM 35 CONTENTS Page 1. Introduction 2 1.1 Getting Started 2 1.2 Overall Description 3 1.3 Features 3 1.4 Block Schematic 4 2. Unit Description 4 2.1 Modules 4 2.2 Main Unit
More informationD115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors
D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to
More informationEWCH 485 Electronic Pulse Counter
Electronic Pulse Counter Technical Data Sheet INSTRUMENT DESCRIPTION GENERAL DESCRIPTION is a programmable microprocessor based counter with 1or 2 outputs. The instrument offers the possibility to program:
More informationIntroduction. Features. Index
Introduction A new standard of performance and functionality in a compact preset counter. The V454501 Single Preset Counter offers a pre-settable counter with full calibration for a variety of applications.
More informationProgrammable Position Indicators
SERIES 54-76 Programmable Position Indicators ( ) ELGO ELECTRIC INCR INCR ABS Series 54 or use with Encoders Series 56 or use with MX magnetic scale Series 74 off Series 54 in one enclosure Series 75 off
More informationOrientation F7 Drive Software Technical Manual
Software Number: VSF11006X, Drive Models: CIMR-F7UXXXXXX-063 Document Number: TM.F7SW.063, Date: 03/03/06, Rev: 06-03 Orientation F7 Drive Software Technical Manual This document is intended to provide
More informationNokeval. No Manual. Models 575F, 1000F, 1100F, Scalable counter for pulse sensors
No 90 Nokeval Manual Models 7F, 000F, 00F, 800-0 Scalable counter for pulse sensors Manufacturer: Nokeval Oy Yrittäjäkatu 700 NOKIA Finland Tel. +8 800 Fax. +8 0 Counter / batch controller XX-0 for pulse
More informationProduct Description. Contents. Fusion Series. New Information December 2003
Fusion Series Technical Data New Information December 2003 Durant Fusion Product Description The Durant Fusion from Eaton Electrical is an industrial control unit consisting of a high speed count control
More informationLAUREL. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets ELECTRONICS, INC. Features.
Description LAUREL ELECTRONICS, INC. Laureate Dual-Channel Pulse Input Totalizer With Two Independently Scalable Input Channels & Presets Features Frequencies up to 1 MHz Totals stored in non-volatile
More informationV E1B Snap-in I/O Module
V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital
More informationUser safety and equipment protection guidelines
Snap-in I/O Module The V200-18-E1 plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. The module offers: 3 analog inputs 16 digital
More informationGIR 230 FR Version 1.1
E33.0.02.6C-02 Manual for connection and operation of GIR 230 FR page 1 of 20 Manual for connection and operation of GIR 230 FR Version 1.1 E33.0.02.6C-02 Manual for connection and operation of GIR 230
More informationNTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY
NTP-5521/5531/5561 SWITCHING MODE POWER SUPPLY USER MANUAL Keep this manual in a safe place for quick reference at all times. This manual contains important safety and operation instructions for correct
More informationInstruction Manual IUC-79-FTF 0-10 VDC. Thresholds: ON: TP1=3V OFF: TP2=1V ON: TP1= OFF: TP2= 100 microsec. Not Installed
Manufacturers of Process Controls and Instrumentation Instruction Manual Model: IUC-79-FTF Function: Frequency to Frequency Isolator Option: Input: -DIV (Frequency Divider) -BUF (Frequency/Pulse Buffer)
More informationBatch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs
Datasheet N410 User-friendly batch controller Reliable Batch Controller with numerical keypad, remote control inputs and 3 control / alarm / pulse outputs Advantages Save time and cost with the easy to
More information10 DIGITAL MICRO-PROCESS TOTALIZER METER with ALARMS / ANALOG OUTPUT / PULSE OUTPUT / RS-485. T Total Alarm x 1 + FRONT PANEL & KEY FUNCTIONS
0 DIGITAL MICRO-PROCESS TOTALIZER METER with ALARMS / ANALOG OUTPUT / PULSE OUTPUT / RS-85 + FEATURES! Accuracy: + - 0.00% F.S. High brightness 0." LED; Rate of display range: 0~99999 Rate / Total decimal
More informationTECO L510 Inverter. Quick Start Guide. Step 1. Supply & Motor connection
Quick Start Guide TECO L510 Inverter This guide is to assist you in installing and running the inverter and verify that it is functioning correctly for it s main and basic features. For detailed information
More informationQuick Start Guide For GVX9000 AF Drives
Quick Start Guide For GVX9000 AF Drives June 2006 New Information 5011646300 00GQ MN04000002E June 2006 Step 1 Wiring Hazardous High Voltage HIGH VOLTAGE! Motor control equipment and electronic controllers
More informationHints for Replacement of Obsolete Controller Models BY240 with New Models BY340
Hints for Replacement of Obsolete Controller Models BY240 with New Models BY340 Previous Configuration: BY240 Synchronous Controller Option: Parallel interface PS240 and BCD thumbwheel switch set BY106-5
More informationMicrocontroller Based Temperature/Process Scanner (Product Code 7.4 to 7.6) MSI-804 with 16 relays
Microcontroller Based Temperature/Process Scanner (Product Code 7.4 to 7.6) MSI-04 MSI-04 with 16 relays Wise Description: Sr. No Product Description (X = channel ) Size (WxHxD) (mm.) 7.4 MSI-04-F-X 7.5
More informationEnergy Management Modular Energy meters Type EM2-96
Energy Management Modular Energy meters Type EM2-96 Product Description µp-based modular energy meter with a built-in configuration key-pad. The energies are both partial and total counted. The housing
More informationElectronic SD1, AS 8, ASR 14, ASR 20
Electronic SD1, AS 8, ASR 14, ASR 20 2 Electronic SD1, AS 8, ASR 14, ASR 20 Contents Page List of contents..................................................... 3 Function and characteristics.........................
More informationSC2000 MOTOR PROTECTION ELECTRONICS, INC. INSTRUCTION MANUAL. Phone: (407) Fax: (407) Vulcan Road Apopka, Florida 32703
SC2000 INSTRUCTION MANUAL MOTOR PROTECTION ELECTRONICS, INC. 2464 Vulcan Road Apopka, Florida 32703 Phone: (407) 299-3825 Fax: (407) 294-9435 Operating Program Revision: 10 Revision Date: 1-9-12 STATION
More informationQuick Start Guide Cutler-Hammer SVX9000 Drives from Eaton Corporation CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and
Quick Start Guide Cutler-Hammer SVX9000 Drives from Eaton Corporation CONTENT STEP 1 Keypad Operation Overview STEP 2 Standard Wiring Diagrams and Connections STEP 3 Start-Up Wizard STEP 4 Operating and
More informationOperating Manual. ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz. Product Features:
Operating Manual ZX020 Miniature Low Cost Counter for Input Frequencies up to 60 khz Product Features: Miniature panel housing Bright LED display with 6 digits Add-on frame for clip or screw mounting Counting
More information7.6 DI Technical Data. 140 DI135 Chapter 3. General Information
7.6 DI135 7.6.1 Technical Data Module ID General Information Model Number Short Description C-UL-US Listed DI135 7DI135.70 2003 digital input module, 4 inputs 24 VDC, sink, incremental encoder operation:
More informationPLCADD1616 User Guide 3/29/10. Overview
PLCADD1616 User Guide 3/29/10 Overview The PLCADD1616 is a PLC expansion board used to add digital inputs and outputs to a compatible host PLC. The PLCADD1616 has 16 relay outputs and 16 optically isolated
More informationDIGITAL DISPLAY. for Industry Applications. Series WAY-D. Key-Features:
DIGITAL DISPLAY for Industry Applications Series WAY-D Key-Features: Content: Technical Data.2 Technical Drawing...2 Electrical Connection...3 Programming...5 Control s...6 Order Code & Accessories...7
More informationAI-917-A0. Analogue Input Module (4x 0-20 ma)
General Specifications GS48D17A00-00E-N AI-917-A0 Analogue Input Module (4x 0-20 ma) GENERAL Figure 1 This module has four analogue inputs and four logic pulse outputs. AI-917-A0 Analogue Input Module
More informationMOD. KBC HEAD KONTAX BATCH CONTROLLER
MOD. KBC HEAD KONTAX BATCH CONTROLLER THE INSTRUMENT DESCRIBED IN THIS MANUAL COMPLIES WITH STANDARDS EMC LIKE ESTABLISHED FROM DIRECTIVE THE EEC AND THE 89/336 DIRECTIVE LOW TENSION THE EEC 73/23 2/2/27
More informationGPIO CONFIGURATION. Screen Touch-Pads <LOCAL RACK> Selects the GPIO in the Local Rack (16 GPIO channels).
CONFIGURATION GPIO In the GPIO (General Purpose Input Output) Page you can configure all GPIO channels that are available in the Soundcraft Vi Series. To access the GPIO page, press the [MENU] key, this
More informationVeeder-Root brand. Squire Dual Preset Counter. Technical Manual
Introduction A new standard of performance and functionality in a compact preset counter. The Squire Dual Preset Counter offers a two level presettable counter and controller for slowdown and stop/cut
More informationMFJ-484 GRANDMASTER MEMORY KEYER CONTROL FUNCTIONS
MFJ-484 GRANDMASTER MEMORY KEYER The MFJ-484 is a highly sophisticated memory keyer using 15 state-of-the-art Integrated Circuits and 4 Random Access Memories which are standards of the industry. It provides
More informationDX 342. Multi Function Counters with 2 Presets, 2 Relay Outputs and Serial RS 232 / RS 485 Interface. Operating Instructions. control motion interface
control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com DX 342 Multi Function Counters with
More informationSERIE 59. Rear clamp. Frontal clamp HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS
HIGH RESOLUTION HOLLOW SHAFT INCREMENTAL ENCODER FOR INDUSTRIAL APPLICATIONS Resolution up to 50.000 pulses per turn External diameter 58 mm Hollow shaft from Ø 10 to 14 mm Protection class IP67 according
More informationLASER. Laser Displacement Transducer. Series LAH-G1. Key-Features:
LASER Laser Displacement Transducer Series LAH-G1 Key-Features: Content: Technical Data...2 Technical Drawing...3 Electrical Connection...4 Order Code...5 ranges up to 300 mm Resolution up to 0.5 μm Protection
More informationCylindrical Proximity Sensor
Cylindrical Proximity Sensor A New Series of Easy-to-use and Tough Models with a Yellow Indicator New series of TL-X2C1-GE models with improved performance over the previous TL-X-E models. Also, in addition
More informationSpeed indicator DR 1010 Revolution per minute - speed - flow
Speed indicator DR 1010 Revolution per minute speed flow Features M LEDDisplay 14.2 mm red M Display range 0... 99999 M 0... 3 decimal points or floating point programmable M Inputs for switching contacts,
More informationBY340 and BY641. High Performance Low Cost Synchronous Controllers. Operating Instructions. control motion interface
control motion interface motrona GmbH Zwischen den Wegen 32 78239 Rielasingen - Germany Tel. +49 (0)7731-9332-0 Fax +49 (0)7731-9332-30 info@motrona.com www.motrona.com BY340 and BY641 High Performance
More informationINSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT
1 INSTRUCTION MANUAL FOR THE MC-01 CONTROL UNIT TABLE OF CONTENTS 1 INSTALLATION... 2 1.1 Mounting... 2 1.2 Mains Connection... 2 1.3 Relay Connection... 3 1.4 Pulse Input Connection... 3 1.5 4-20 ma Output
More informationIPM650 Intelligent Panel-Mount Display
Quick Start Guide IPM650 Intelligent Panel-Mount Display Sensor Solutions Source Load Torque Pressure Multi Component Calibration Instruments Software www.futek.com Getting Help TECHNICAL SUPPORT For more
More informationBatch Controller with numerical keypad and receipt printer driver
Datasheet N413 Batch Controller for ticket printing Reliable Batch Controller with numerical keypad and receipt printer driver Advantages Save time and cost with the easy to operate numerical keypad. Your
More informationVeeder-Root brand C346 Preset Counter Rate Meter Time Counter
Introduction The Veeder-Root brand C346 family offers a new level of performance in a 1/16 DIN instrument. Fully programmable to operate as a preset counter, a rate meter (with outputs) or an elapsed time
More informationinstallation Operation ADDRESS product diagram H8030/8031 INSTALLATION GUIDE
POWER MONITORING INSTALLATION GUIDE H8030/8031 H8030/8031 Modbus Energy Meter Networked kw/kwh Transducer Product Identification Model Max Amps CT Size Enhanced Data Stream Meters H8030-0100- 100 H8030-0300-
More informationADDJOG User Guide 7/30/10. Overview
ADDJOG User Guide 7/30/10 Overview The ADDJOG is a PLC expansion board used to add digital inputs and outputs to a compatible host PLC. The ADDJOG has 64 open collector outputs and 64 non-isolated inputs.
More informationDIGITAL DISPLAY. for Industry Applications. Serie REX-D. Key-Features:
DIGITAL DISPLAY for Industry Applications Serie REX-D Key-Features: Content: 01.07.16 - REX-D-X345: only display - REX-D-X347: display with two presets and switching out puts - REX-D-X348: Display with
More information1.6. Counters, Panel Meters, Tachometers and Timers. Contents Description Fusion Integrated Machine Control Standards and Certifications...
.6 Contents Standards and Certifications............... Product Selection....................... Technical Data and Specifications........... Dimensions............................ Learn Online Page V3-T-04
More informationTachometers TC-4B-V TC-6A-V Electronic cam-operated switching devices FC-21-V... 50
List of content page Counters and indicators DA5-IU-C... 10 DA5-IU-2K-C... 12 DA5-IU-2K-V... 12 KCM-51-C... 14 KCM-51-V... 14 KCM-70-C... 16 KCM-70-V... 16 KCM-70A-C... 18 KCM-70A-V... 18 KCT-6S-C... 20
More information7511 / / / 711 / / 731 / Preset 27
22 Timers Timers Electronic 23 7511 / 3410 23 6320 / 720-6300 24 ElectRo-MeCH 25 710 / 711 / 720 25 722 / 731 / 732 26 Preset 27 7932 27 Electronic 23 7511 Series 8 digit self powered LCD electronic timer
More informationSENSORLESS VECTOR CONTROL
D SERIES EM16 STANDARD DRIVE SENSORLESS VECTOR CONTROL EM16 STANDARD DRIVE SENSORLESS VECTOR CONTROL 1 2 SERIES 1 2 page 4 page 6 Introduction Fields of application 3 page 7 4 page 8 Designation Product
More informationLAUREL ELECTRONICS, INC.
Description LAUREL ELECTRONICS, INC. Laureate Pulse or Analog Input Batch Controller Automatic batch control for repetitive liquid fill operations Features Available for turbine flow meter pulse signals
More informationMODEL 715AN QUADRATURE DEGREES COUNTER
MODEL 715AN QUADRATURE DEGREES COUNTER DESIGN CONCEPTS INC 707 N. Lindenwood Olathe, Kansas 66062 PHONE: (913) 782-5672 FAX: (913) 782-5766 E-MAIL : info@dcimeters.com 0411 TABLE OF CONTENTS 2. Features
More informationCheckSum. FUNC-2B Functional Test Module. The FUNC-2B features:
CheckSum FUNC-2B Functional Test Module FUNC-2B Functional Test Module Made in U.S.A. The CheckSum Model FUNC-2B Functional Test System is designed to be used as an extension to a CheckSum ICT System.
More information407B 1/16 DIN Multi-Mode Timer
< Marsh Bellofram Group of Companies < Automatic Timing & Controls < Timer < 407B Series Downloadable Files: 407B Series 407B 1/16 DIN Multi-Mode Timer Selectable On-Delay/Off-Delay/Interval Timing Modes
More informationV E2B Snap-in I/O Module
i4 Automation Ltd - 01480 395256 V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration.
More information405A Timer with Instantaneous Relay
< Marsh Bellofram Group of Companies < Automatic Timing & Controls < Timer < 405A Series Downloadable Files: 405A Series 405A Timer with Instantaneous Relay On-Delay version with instantaneous relay Selectable
More information02/11/2015
DIN Rail Mount 35 mm HSV Part number 84874320 Control of overspeed, underspeed, operating rate, stopping Measurement via discrete sensors - 3-wire PNP or NPN, Namur, voltage 0-30V or volt-free contact
More informationGFC111-MB. Flow Computer With RS485 MODBUS FEATURES 1. DESCRIPTION APPLICATIONS
Flow Computer With RS485 MODBUS FEATURES l RS485 MODBUS RTU, 1/8 LOAD l PROGRAMMABLE ADDRESS, BAUD RATE, PARITY AND STOP BITS l UNIVERSAL INPUT, 5 khz, CAN POWER THE SENSOR l NO NEED OF AMPLIFIERS OR LINEARIZERS
More informationInstallation & Operation
LED Readout Installation & Operation WARRANTY Accurate Technology, Inc. warrants the ProScale Systems against defective parts and workmanship for 1 year commencing from the date of original purchase. Upon
More informationInductive and Capacitive Proximity Sensors Identification Codes. Product Type/Size Output Type of Sensing Options Group of Housing Output Distance
Proximity Sensors Inductive Sensors Inductive Proximity Sensors are used when the target or object to be sensed is metal. Inductive types are the most widely used proximity sensors for industrial applications.
More informationY800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels
Y800 Plus Frequency, Rate & Period Meter With dual, independently field-scalable channels Description Features Frequencies from 0.005 Hz to 1 MHz 6-digit resolution at update rates up to 25/s Selectable
More informationDX 345, DX 346, DX 347, DX 348
control motion interface DX 345, DX 346, DX 347, DX 348 Universal Display Units with Impulse Inputs DX 345: DX 346: DX 347: DX 348: Display only Display with Analogue Output Display with Two Presets and
More informationKTC. Preset Counter/ Timer. Programmable Type. Model Number Legend SALIENT FEATURES. Sensing. Digital Panel Meters
Preset Counter/ Timer Programmable Type Model Number Legend SALIENT FEATURES 6 Digits PV, SV Universal Input Dual alarm output MODBUS via RS-485 High Speed - 10 KCPS Multiple output modes Batch Counting,
More informationQuick Reference Elgar PIP9012A Series
Quick reference guide to using the Elgar PIP9012A series plug in programmers. Some of the features described herein are options installed on the power source and/or the PIP9012A. The following section
More informationTechnical specifications
Technical specifications General information Operating temperature -25 to 60 C Storage temperature -40 to 70 C Enclosure type Panel installation (DIN IEC 61554) Enclosure fixing Screw-type clamping technology
More informationHybrid AC Driver [GCNC-1110]
Page 1 Installation Manual and Datasheet Page 2 Key Features Smooth and quiet operation at all speeds and extremely low motor heating Industrial grade performance for an alternating current servo motor
More informationCONFIGURABLE FREQUENCY INDICATOR - INTERCEPTOR. Main input. Scale limits. Alarms (set points) Alarm masking. Relay contact. Triac output (option)
40F 96 CONFIGURABLE FREQUENCY INDICATOR INTERCEPTOR USER S MANUAL SOFTWARE VERSION.0x code 867A / edition 0.5 0/04 INSTALLATION Dimensions and cutout: Panel mounting 2 TECHNICAL SPECIFICATIONS Display
More informationVorne Industries. 87/415 Rate Monitor Display User's Manual Industrial Drive Itasca, IL (630) Telefax (630)
Vorne Industries 87/415 Rate Monitor Display User's Manual 1445 Industrial Drive Itasca, IL 60143-1849 (630) 875-3600 Telefax (630) 875-3609 . 3 Chapter 1 Setting Up Your Display For Operation... 1.1 Accessing
More informationLAUREL. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input ELECTRONICS, INC. Features. Description
LAUREL ELECTRONICS, INC. MAGNA Series Large Digit Displays for Counter / Totalizer Pulse Input Features Choice of 2-1/4", 4", 6" or 8" digit heights Choice of 4 or 6 digits with decimal points Choice of
More informationPeak/Valley Hold Unit (PVHU) User Manual V3.00
Peak/Valley Hold Unit (PVHU) User Manual V3.00 Part Number: DO-UM0084/30/UE Applies to Firmware Version: V3.01 Reference: Peak_Valley Hold Unit (PVHU) User Manual.docx Date: 30 May 2016 Version: 3.00 Peak/Valley
More informationIO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs
IO-DI8-TO8 I/O Expansion Module 8 Inputs, 8 Outputs The IO-DI8-TO8 is an I/O expansion module that can be used in conjunction with specific Unitronics OPLC controllers. The module offers 8 digital inputs,
More informationAbsolute Rotary Encoder E6C-N. Ordering Information. Ideal for Stepping Motor Tripping Detection and Position Control of Loaders or Unloaders
Absolute Rotary Encoder Ideal for Stepping Motor Tripping Detection and Position Control of Loaders or Unloaders No need to reset origin point at power-up IP50 certification Ideal for packaging, plastics,
More informationThe PM1000 series is a universal 4 digit LED plug-on display for transmitters with 4-20mA 2 wire output and fitted with DIN43650 connector.
PM1000 SERIES PLUG-ON DISPLAY BRIGHT LED DISPLAY INDICATION RANGE -999 TO +9999 FITS TO DIN 43650 CONNECTOR PLUG-ON TO ANY TRANSMITTER WITH 4-20MA OUTPUT EASY TO SCALE ON SITE ROBUST DESIGN SET POINT OPTION
More informationVeeder-Root brand Series S628 Strain Gauge (S628-6XXX)
Introduction Your Veeder-Root brand S628 Strain Gauge is one model in a family of 1/8 DIN units which offers breakthrough display technology as well as easy-to-program single-line parameters. Designed
More informationS-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT
S-Line HIGH BRIGHTNESS AND ACCURACY DIGITAL LED INDICATORS 100% Made & Designed in Italy MODULAR INDICATORS / TOTALIZERS WITH UNIVERSAL ANALOG INPUT INDICATORS / SIGNAL GENERATORS WITH ANALOG INPUT COMPACT
More informationV E1B Snap-in I/O Module
V200-18-E1B Snap-in I/O Module The V200-18-E1B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital
More informationV E2B Snap-in I/O Module
V200-18-E2B Snap-in I/O Module The V200-18-E2B plugs directly into the back of compatible Unitronics OPLCs, creating a selfcontained PLC unit with a local I/O configuration. Features 16 isolated digital
More information