Annex E - Standard Parts
|
|
- Chad Houston
- 6 years ago
- Views:
Transcription
1 IDM UID 4H8SJC VERSION CREATED ON / VERSION / STATUS 20 Jun 2012 / 2.0/ Approved EXTERNAL REFERENCE Handbook (not under Configuration Control) Annex E - Standard Parts This document contains the RH control system standard parts requirements. A DA review was held on a pre-release (RHCS Handbook Annex E v1.1 review report (A6TE26)) and the report comments have been applied in version 2.0. Approval Process Name Action Affiliation Author Hamilton D. 20-Jun-2012:signed IO/DG/DIP/CIE/AOP/RH CoAuthor Reviewers Choi C.- H. Friconneau J.- P. Nakahira M. Palmer J. Tesini A. Blackler K. 21-Jun-2012:recommended 04-Jul-2012:recommended 06-Jul-2012:recommended 21-Jun-2012:recommended 10-Jul-2012:recommended 27-Jul-2012:recommended IO/DG/DIP/CIE/AOP/RH IO/DG/DIP/CIE/AOP/RH IO/DG/DIP/CIE/AOP/RH IO/DG/DIP/CIE/AOP/RH IO/DG/DIP/CIE/AOP/RH IO/DG/DIP/CIE/AOP Approver Kondoh M. 27-Sep-2012:approved IO/DG/DIP/CIE Document Security: level 1 (IO unclassified) RO: Tesini Alessandro Read Access RO, project administrator, AD: ITER, AD: External Collaborators, AD: Section - Remote Handling, AD: Section - Remote Handling - EXT PDF generated on 27-Sep-2012 DISCLAIMER : UNCONTROLLED WHEN PRINTED PLEASE CHECK THE STATUS OF THE DOCUMENT IN IDM
2 Change Log Title (Uid) Version Latest Status Issue Date Description of Change Annex E - Standard Parts (4H8SJC_v2_0) v2.0 Approved 20 Jun 2012 The results of the RH standard parts evaluations and the CODAC updates to their catalogue items were taken into account in this major update of the Annex E - Standard Parts document. The Annex E document provides the function and interface requirements for the parts of the RH Control System architecture. The recommended solutions for these parts are provided in a separate catalogue document (ITER_D_A6CMLW). Annex E - Standard Parts (4H8SJC_v1_0) v1.0 Approved 28 Jun 2011 PDF generated on 27-Sep-2012 DISCLAIMER : UNCONTROLLED WHEN PRINTED PLEASE CHECK THE STATUS OF THE DOCUMENT IN IDM
3 RHCS Design Handbook Annex E Standard Parts Table of Contents 1 Introduction Overview Abbreviated terms, acronyms and definitions References RH Infrastructure File Network Control Network Real-time network Audio-Video Network Diagnostic network Communication Middleware Communication Protocol Video Signal Distribution Protocol Emergency Stop System Software Development Environment High-Level Control System One Arm Force-Feedback Master Device Two Arm Force-feedback Master device Joystick Device Emergency Stop Buttons Viewing Monitors Desktop Operating System Server Operating System Database System Operations Management System Command & Control Virtual Reality Computer Assisted Teleoperation Structural Simulator Synthetic Viewing System Remote Diagnostic Structured Language ITER Organization 1
4 4 Low-Level Control System Electrical Distribution Board Electrical Distribution Panel Cubicle External Connectors Penetration Connectors Field cabling Real-Time Operating System (RTOS) Operating Framework RH Library On-Line Condition Monitoring Control Cubicle Products General Purpose Processor Board Control Unit Communication Bus Field Communication Bus General I/O Programmable Logic Controller Motion Controller Resolver Driver Strain Gauge Driver Camera Driver Auxiliary Joint Driver Main Joint Driver Heavy Duty Joint Driver Hydraulic Servo Valve Hydraulic Solenoid Valve Power Relay ITER Organization 2
5 1 Introduction 1.1 Overview The project wishes to control the complexity of the I&C by encouraging the use of standard COTS parts. The CODAC section has defined a number of standard parts for ITER I&C [1], the electrical section has defined standards for electrical parts [2], and the RH section has instigated a programme of evaluation studies [3] to identify suitable standard parts for the functional roles defined in the RH specifications. This document will be used to identify the function and interface requirements of the RH control system standard parts. The actual standard parts shall be listed in a separate document (RH standard parts catalogue [4]) that will be updated as-and-when suitable parts are identified. The products specified in the RH standard parts catalogue to fulfil the standard part requirements are provided as guidelines to the suppliers. The IO will encourage and facilitate the use of the guideline products, but the supplier is responsible for taking due diligence in the selection of parts for use in the supply of a system. [RQ-E-001] The RH equipment system design parts shall be compatible with the function and interface requirements that are defined in this document. 1.2 Abbreviated terms, acronyms and definitions API CAT CODAC COTS C&C EDH HLCS HMI IO IT I/O LAN LLCS NTP OMS PBS PLC POSIX RH RHCS RT RTOS R&D SCS UML USB VR Application Programming Interface Computer Assisted Teleoperation Control, Data Acquisition, and Communication Commercial Off-The-Shelf Command & Control Electrical Design Handbook High-Level Control System Human Machine Interface ITER Organization Information Technology Input/Output Local Area Network Low-Level Control System Network Timing Protocol Operations Management System Plant Breakdown Structure Programmable Logic Controller Portable Operating System Interface Remote Handling Remote Handling Control System Real-Time Real-Time Operating System Research and Development Supervisory Control System Unified Modeling Language Universal Serial Bus Virtual Reality ITER Organization 3
6 1.3 References [1] Satellite documents to CODAC Plant Control Design Handbook (27LH2V). [SD12] Slow Controller catalogue (333J63 v1.7), [SD13] Guidelines for fast controllers (333K4C v1.3), [SD14] Fast Controller products catalogue (345X28 v1.3), [SD15] Cubicle products catalogue (35LXVZ v2.3), [SD16] Guidelines for the design of the PIS (3PZ2D2, v2.4), [2] Electrical Design Handbook (EDH) [3] RH standard parts evaluation folders (6UNJ3R), (6V9RJU). WP4-5 Controller Interface Protocol Evaluation Report (6UVMLD) [4] RH Control System Standard Parts Catalogue (A6CMLW) [5] ITER Process for Human Machine Interface (HMI) Development (3T9UK2). ITER Organization 4
7 2 RH Infrastructure The IO RH section will install a basic infrastructure for the RH equipment systems to integrate with in order to become part of the overall RH System. This integrating infrastructure is procured through the Supervisory Control System (23.07) and the compatibility with the infrastructure shall be handled through the interfaces between the RH equipment systems (23.01, 23.02, 23.03, 23.05, 23.06, 23.10) and The RH infrastructure parts include:- File Network Control Network Real-time Network Audio-Video Network Diagnostic Network Communication Middleware Communication Protocol Video Signal Distribution Protocol Emergency Stop System Software Development Environment ITER Organization 5
8 2.1 File Network Function [RQ-E-002] The File Network shall provide the general backbone for communication between high-level control system applications within the Plant Operating Zone. [RQ-E-003] The File Network shall support general application traffic such as file transfers, loading of applications from servers, server calls, and so on Interface [RQ-E-004] The interface shall be the general personal computer standard for gigabit Ethernet network. [RQ-E-005] The RH high-level control system applications shall connect to the File Network Standard Part ITER Organization 6
9 2.2 Control Network Function [RQ-E-006] The Control Network shall provide the mechanism for communication of RH operation control data between the high-level control system applications and the low-level control system applications. [RQ-E-007] The CODAC Network Timing Protocol (NTP) shall be implemented through the RH Control Network. [RQ-E-008] The traffic on the Control Network shall be controlled so that 99.9% of operator initiated command messages are processed with less than 50msec delay Interface [RQ-E-009] The RH equipment system interfaces with the Control Network shall be handled through the communications interface sheet with PBS Standard Part ITER Organization 7
10 2.3 Real-time network Function [RQ-E-010] The Real-time (RT) Network provides a mechanism for digital communication between RH controllers with high reliability deterministic timing. [RQ-E-012] The bandwidth of the Real-time Network shall support, as a minimum, 10 pairs of controllers sending and receiving 128 byte data packages at 1kHz cycle rate. [RQ-E-013] The average variation in timing of the reception of packages (jitter) shall be less than 20µsec. [RQ-E-014] The occurrence of a delay greater than 100 µsec in reception of a data package shall be less than 1 in (this is considered a missed deadline). [RQ-E-015] The occurrence of more than two consecutive missed deadlines shall be less than 1 in 10,000,000,000 (approximately a year of RH controller operation). [RQ-E-016] The RH controllers should be able to continue operation through 2 missed control cycles. The RH controllers should trip to safe state if the number of consecutive missed data packages exceeds the controller safe limits, and in any case if 5 consecutive deadlines are missed Interface [RQ-E-017] The RH equipment system interfaces with the Real-time Network shall be handled through the communications interface sheet with PBS Standard Part ITER Organization 8
11 2.4 Audio-Video Network Function [RQ-E-018] The Audio-Video Network shall provide the mechanism for communication of RH audio and video signal data. [RQ-E-019] The Audio-Video Network shall implement a mechanism for reserving bandwidth for point-topoint connections so that video data can be streamed at a regular rate with low jitter. [RQ-E-020] The Audio-Video Network shall be sized to support simultaneous viewing of up to one hundred and twenty 640x480 pixel resolution video signals at 30Hz update rate in each of the RH control rooms Interface [RQ-E-021] The RH equipment system interfaces with the Audio-Video Network shall be handled through the communications interface sheet with PBS Standard Part ITER Organization 9
12 2.5 Diagnostic network Function [RQ-E-022] The Diagnostic Network shall provide the mechanism for communication of RH equipment diagnostic data between the low-level control system applications and the high-level control system applications Interface [RQ-E-023] The RH equipment system interfaces with the Diagnostics Network shall be handled through the communications interface sheet with PBS Standard Part ITER Organization 10
13 2.6 Communication Middleware Function [RQ-E-024] The Communication Middleware shall provide a standard mechanism for communication between the heterogenous applications of the RH control system. [RQ-E-025] The Communication Middleware shall provide connection management. [RQ-E-026] The Communication Middleware shall support synchronous function calls (remote procedure calls). [RQ-E-027] The Communication Middleware shall support asynchronous messaging (events/alarms). [RQ-E-028] The Communication Middleware shall support bulk data transfers (file transfers) Interface [RQ-E-029] The Communication Middleware shall be compatible with the IO/RH standard communication protocol. [RQ-E-030] The RH equipment system interfaces with the Communication Middleware shall be handled through the communications interface sheet with PBS Standard Part ITER Organization 11
14 2.7 Communication Protocol Function [RQ-E-031] The Communication Protocol shall define a standard set of rules for RH operation control communications. [RQ-E-032] The Communication Protocol shall define the protocol for managing connections between applications. [RQ-E-033] The Communication Protocol shall define the protocol for managing the operator high-level behaviour commands to RH equipment controllers (complex list of commands with varying parameters). [RQ-E-034] The Communication Protocol shall define the protocol for reading and writing application control parameters. [RQ-E-035] The Communication Protocol shall define the protocol for managing periodic RH equipment controller status reports (complex data telegrams). [RQ-E-036] The Communication Protocol shall define the protocol for managing asynchronous reporting of events and alarms. [RQ-E-037] The Communication Protocol shall define the protocol for transferring bulk data. [RQ-E-038] The Communication Protocol shall define the primitive data types for RH operation control communications Interface [RQ-E-039] The RH equipment system operation control communications shall be compatible with the RH standard Communication Protocol [3]. [RQ-E-040] The RH equipment system diagnostic communications shall be compatible with the RH standard Communication Protocol [3] Standard Part ITER Organization 12
15 2.8 Video Signal Distribution Protocol Function [RQ-E-041] The Video Signal Distribution Protocol shall provide a standard and efficient way of distributing video signals over the audio-video network (to monitors or recording devices). [RQ-E-042] The Video Signal Distribution Protocol shall provide low-latency streaming of video over a local area network Interface [RQ-E-043] The Video Signal Distribution Protocol shall be compatible with the IO/RH Audio-Video Network. [RQ-E-044] The Video Signal Distribution Protocol shall be compatible with the RH standard for viewing monitors Standard Part ITER Organization 13
16 2.9 Emergency Stop System Function [RQ-E-045] The Emergency Stop System shall provide a hierarchical push-button network for tripping the emergency stop circuits of groups of RH equipment controllers. [RQ-E-046] The Emergency Stop System shall be compatible with French regulations in personnel safety. [RQ-E-047] The Emergency Stop System shall be compatible with a configuration involving two control rooms with:- Supervisor station with emergency stops to trip all controllers operating from control room, Six work-cells with emergency stops to trip all controllers operating from work-cell, Average of 16 controllers being operated from a work-cell. [RQ-E-048] The Emergency Stop System shall be configurable so that the controllers linked to a control room work-cell can be re-defined from one RH shutdown to another. [RQ-E-049] The Emergency Stop System shall be compatible with distributed RH controllers over distances up to 1km Interface [RQ-E-050] The Emergency Stop System distribution between controller locations and server room shall be compatible with a single 20mm diameter cable. [RQ-E-051] The RH equipment system interfaces with the Emergency Stop System shall be handled through the interface with PBS Standard Part ITER Organization 14
17 2.10 Software Development Environment Function [RQ-E-052] The Software Development Environment shall provide a standard environment for developing ITER/RH software applications. [RQ-E-053] The Software Development Environment shall be compatible with software development in Java, C/C++, Python programming languages. [RQ-E-054] The Software Development Environment shall provide build and debugging tools for the development of the RH high-level control system applications. [RQ-E-055] The Software Development Environment shall provide build and debugging tools for the development of the RH low-level control system applications. [RQ-E-056] The Software Development Environment shall provide a toolkit for developing graphical user interfaces. [RQ-E-057] The Software Development Environment shall provide a toolkit for developing embedded controller applications. [RQ-E-058] The Software Development Environment shall support the use of the Unified Modeling Language Interface [RQ-E-059] The Software Development Environment shall be compatible with the RH standard Desktop Operating System. [RQ-E-060] The Software Development Environment shall be compatible with the CODAC software management tools (Subversion, Bugzilla, Maven). [RQ-E-061] The RH equipment system software shall be compatible with the IO/RH Software Development Environment Standard Part ITER Organization 15
18 3 High-Level Control System The high-level control system concerns the operator interfaces in the RH control room(s). Each RH equipment system provides a high-level control system for operation of its RH equipment, and these shall contain the parts/modules defined by the RH control system architecture. The RH high-level control system parts include:- One Arm Force-Feedback Master Device Two Arm Force-Feedback Master Device Joystick Device Emergency Stop Buttons Viewing Monitors Desktop Operating System Server Operating System Database System Operations Management System Command & Control Virtual Reality Computer Assisted Teleoperation Structural Simulator Synthetic Viewing System Remote Diagnostic Structured Language ITER Organization 16
19 3.1 One Arm Force-Feedback Master Device Function [RQ-B-043] The 1 arm master-arm device shall fulfil the following technical requirements:- full 6 degree of freedom in Cartesian space plus gripper, workspace shall contain a 400mm sided cube as a minimum, capable of exerting a sustained maximum force in the range 30N to 60N, shall have a maximum tip speed in the range 600mm/sec to 1200mm/sec, static friction overcome with a force less than 2% of the arm maximum sustained force, shall move smoothly with a force ripple less than 1% of maximum sustained force, shall have a Cartesian position resolution of better than working range/10000, shall have a Cartesian velocity resolution of better than max speed/200. [RQ-E-062] The One Arm Force-feedback Master device shall be configurable for use with kinematically dissimilar slave devices. [RQ-E-063] The One Arm Force-feedback Master device shall support on-line modification (scaling, offsetting) of mapping between master and slave work spaces. [RQ-E-064] The One Arm Force-feedback Master device controller shall comply with the controller requirements expressed in the main body and Annex C of the RHCS Design Handbook. [RQ-E-065] The height of the master arm shall be adjustable to support operation of the device in operator sitting and standing positions Interface [RQ-E-066] The One Arm Force-feedback Master device controller shall be compatible with the space and mounting allowed in the RH standard work-cell. [RQ-E-067] The One Arm Force-feedback Master device controller shall communicate with high-level control system applications (such as Command & Control) using the RH Control Network. [RQ-E-068] The One Arm Force-feedback Master device Control Network communications shall be compatible with the RH standard middleware and communication protocols. [RQ-E-069] The One Arm Force-feedback Master device controller shall communicate with the slave arm controller using the RH real-time network Standard Part ITER Organization 17
20 3.2 Two Arm Force-feedback Master device Function [RQ-E-070] The Two Arm Force-feedback Master device shall provide high sensitivity force-feedback position control over two ITER servo-manipulator arms deployed in hazardous areas. [RQ-E-071] The Two Arm Force-feedback Master device shall provide force-feedback position control over single ITER power manipulator arms deployed in hazardous areas. [RQ-B-043] Each of the arms of the two arm master device shall fulfil the following technical requirements:- full 6 degree of freedom in Cartesian space plus gripper, workspace shall contain a 400mm sided cube as a minimum, capable of exerting a sustained maximum force in the range 30N to 60N, shall have a maximum tip speed in the range 600mm/sec to 1200mm/sec, static friction overcome with a force less than 2% of the arm maximum sustained force, shall move smoothly with a force ripple less than 1% of maximum sustained force, shall have a Cartesian position resolution of better than working range/10000, shall have a Cartesian velocity resolution of better than max speed/200. [RQ-E-072] The Two Arm Force-feedback Master device shall be configurable for use with kinematically dissimilar slave devices. [RQ-E-073] The Two Arm Force-feedback Master device shall support on-line modification (scaling, offsetting) of mapping between master and slave work spaces. [RQ-E-074] The Two Arm Force-feedback Master device controller shall comply with the controller requirements expressed in the main body and Annex C of the RHCS Design Handbook. [RQ-E-075] The height of the master arms shall be adjustable to support operation of the device in operator sitting and standing positions. [RQ-E-076] The separation between the two master arms shall be adjustable up to 2m Interface [RQ-E-077] The Two Arm Force-feedback Master device controller shall be compatible with the space and mounting allowed in the RH standard work-cell. [RQ-E-078] The Two Arm Force-feedback Master device controller shall communicate with high-level control system applications (such as Command & Control) using the RH Control Network. [RQ-E-079] The Two Arm Force-feedback Master device Control Network communications shall be compatible with the RH standard middleware and communication protocols. [RQ-E-080] The Two Arm Force-feedback Master device controller shall communicate with the slave arm controller using the RH real-time network Standard Part ITER Organization 18
21 3.3 Joystick Device Function [RQ-E-081] The Joystick requirements shall comply with input device requirements provided in annex B of the RHCS Design handbook (RQ-B-044, RQ-B-045, RQ-B-046, RQ-B-039, RQ-B-040, RQ-B-042, RQ-B- 095). [RQ-E-082] The Joystick Device shall provide a guiding force to assist operators in controlling a single degree of freedom at a time if required. [RQ-E-083] The Joystick Device shall a minimum resolution of 128 unique measurements linear over with working range of the 6 degrees of freedom Interface [RQ-E-084] The Joystick requirements shall comply with input device interface requirements provided in annex B of the RHCS Design handbook (RQ-B-047, RQ-B-048). [RQ-E-085] The Joystick device shall provide a USB interface to a Joystick controller that serves many joysticks. [RQ-E-086] The Joystick device shall include drivers compatible with integration to RH applications. [RQ-E-087] The Joystick device shall be compatible with mounting on RH control room desks Standard Part ITER Organization 19
22 3.4 Emergency Stop Buttons Function [RQ-E-088] The Emergency Stop Buttons shall provide operators with a single action pushbutton mechanism for activating an emergency stop trip. [RQ-E-089] Once pressed an Emergency Stop Button shall latch this state until released by an operator. [RQ-E-090] The Emergency Stop Buttons shall be compatible with French regulations in personnel safety Interface [RQ-E-091] The Emergency Stop Buttons shall be compatible with connection to the Emergency Stop System. [RQ-E-092] The Emergency Stop Buttons shall be compatible with fixing to RH control room desks. [RQ-E-093] The Emergency Stop Buttons shall be compatible with fixing to RH controller cubicles. [RQ-E-094] The Emergency Stop Buttons shall be compatible with attaching to a flying lead Standard Part ITER Organization 20
23 3.5 Viewing Monitors Function [RQ-E-095] The Viewing Monitors shall provide the display of video signals that are streamed over the audiovideo network. [RQ-B-076] The Viewing monitors shall provide the following camera signal display functionality:- Connection to video network, Display of viewing signal sent to monitor Interface [RQ-E-096] The Viewing Monitors shall connect to the RH audio-video network. [RQ-E-097] The Viewing Monitors shall be compatible with the RH standard for video signal distribution over the audio-video network Standard Part ITER Organization 21
24 3.6 Desktop Operating System Function [RQ-E-098] The Desktop Operating System shall provide general computer operating system support to RH high-level control system applications Interface [RQ-E-099] The Desktop Operating System shall install on and interface with desktop and laptop personal computers. [RQ-E-100] The Desktop Operating System shall be compatible with the RH standard Software Development Environment. [RQ-E-101] The Desktop Operating System shall interface with the RH networks. [RQ-E-102] The Desktop Operating System shall be compatible with the deployment of the RH standard communication middleware Standard Part ITER Organization 22
25 3.7 Server Operating System Function [RQ-E-103] The Server Operating System shall provide server computer operating system support to RH server applications. [RQ-E-104] The Server Operating System shall manage and facilitate use of the server computer hardware resources. [RQ-E-105] The Server Operating System shall provide a desktop environment with tools and services for the management of data and applications on the server computer Interface [RQ-E-106] The Server Operating System shall install on and interface with server computers. [RQ-E-107] The Server Operating System shall be compatible with providing server services to the RH standard Desktop Operating System. [RQ-E-108] The Server Operating System shall interface with the RH networks. [RQ-E-109] The Server Operating System shall be compatible with the deployment of the RH standard communication middleware. [RQ-E-110] The Server Operating System shall be compatible with the installation of RH standard database system Standard Part ITER Organization 23
26 3.8 Database System Function [RQ-E-111] The Database System shall provide relational database services to RH control system applications. [RQ-E-112] The Database System shall support a database size in excess of 100 gigabyte Interface [RQ-E-113] The Database System shall conform to the ANSI-SQL:2008 standard. [RQ-E-114] The Database System shall be compatible with the RH standard Server Operating System. [RQ-E-115] The Database System shall be compatible with developments using the RH standard Software Development Environment. [RQ-E-116] The Database System shall be compatible with integration to CODAC databases Standard Part ITER Organization 24
27 3.9 Operations Management System Function The Operations Management System (OMS) is a tool for managing the planning, execution, and reporting of RH operation campaigns. [RQ-E-117] The OMS shall support parallel use by a minimum of 10 client connections (operators working on different parts of RH operation procedures). The OMS requirements are provided in annex B of the RHCS Design handbook (RQ-B-011, RQ-B-012, RQ- B-013, RQ-B-014, RQ-B-015, RQ-B-016, RQ-B-017, RQ-B-018, RQ-B-019, RQ-B-020, RQ-B-021, RQ-B- 022, RQ-B-023, RQ-B-001, RQ-B-002, RQ-B-003, RQ-B-004, RQ-B-005, RQ-B-006, RQ-B-007, RQ-B-008, RQ-B-009, RQ-B-010) Interface OMS interface requirements are provided in annex B of the RHCS Design handbook (RQ-B-024, RQ-B-025, RQ-B-026, RQ-B-027). [RQ-E-118] The OMS shall be compatible with the RH standard Desktop Operating System. [RQ-E-119] The OMS software shall be compatible with the RH standard Software Development Environment. [RQ-E-120] The OMS shall support use of the RH standard Structured Language for recording operation procedures. [RQ-E-121] The OMS shall communicate the progression through operation procedures over the RH control network using the Structured Language format (so that other high-level control system applications such as Command & Control and Virtual Reality can be informed). [RQ-E-122] The OMS shall conform to the RH standard Database system. [RQ-E-123] The OMS shall be compatible with the ITER Engineering Database Standard Part ITER Organization 25
28 3.10 Command & Control Function The Command & Control (C&C) application provides a unified operator interface for commanding RH equipment system operations. The C&C requirements are provided in annex B of the RHCS Design handbook (RQ-B-094, RQ-B-028, RQ- B-029, RQ-B-030, RQ-B-031, RQ-B-032, RQ-B-033, RQ-B-034, RQ-B-084, RQ-B-085, RQ-B-086, RQ-B- 087, RQ-B-088, RQ-B-089, RQ-B-090, RQ-B-091, RQ-B-092, RQ-B-093) Interface C&C interface requirements are provided in annex B of the RHCS Design handbook (RQ-B-035, RQ-B-036, RQ-B-037, RQ-B-038). [RQ-E-124] The C&C shall be compatible with the RH standard Desktop Operating System. [RQ-E-125] The C&C software shall be compatible with the RH standard Software Development Environment. [RQ-E-126] The C&C communications with the low-level control system shall conform to the RH standard communication protocol. [RQ-E-127] The C&C shall support use of the RH standard Structured Language for recording RH equipment system automated sequences. [RQ-E-128] The C&C shall comply with the ITER process for human machine interface development [5] Standard Part ITER Organization 26
29 3.11 Virtual Reality Function The VR system provides live 3D monitoring of the remote handling operations. The VR requirements are provided in annex B of the RHCS Design handbook (RQ-B-049, RQ-B-050, RQ-B- 051, RQ-B-054, RQ-B-055, RQ-B-056) Interface VR interface requirements are provided in annex B of the RHCS Design handbook (RQ-B-059, RQ-B-060, RQ-B-061, RQ-B-062). [RQ-E-129] The VR shall be compatible with the RH standard Desktop Operating System. [RQ-E-130] The VR shall interface with the RH standard Computer Assisted Teleoperation in order to define the environment for the force calculations. [RQ-E-131] The VR shall interface with the RH standard Structural Simulator for structural position updates. [RQ-E-132] The VR shall be compatible with the RH standard Structured Language for tracking RH equipment operations Standard Part ITER Organization 27
30 3.12 Computer Assisted Teleoperation Function The Computer Assisted Teleoperation (CAT) provides force assistance to RH operations based on modelling of forces and collisions in a 3D virtual environment. The CAT requirements are provided in annex B of the RHCS Design handbook (RQ-B-053, RQ-B-054, RQ- B-058) Interface [RQ-E-133] The CAT shall be compatible with the RH standard Desktop or Server Operating System. [RQ-E-134] The CAT shall interface with the RH standard Virtual Reality system using the RH standard Communication Middleware. [RQ-E-135] The CAT shall interface with the RH equipment controllers for position and load updates using the RH standard Communication Protocol. [RQ-E-136] The CAT shall interface with the RH standard Structural Simulator system using the RH standard Communication Middleware Standard Part ITER Organization 28
31 3.13 Structural Simulator Function The Structural Simulator provides simulation of the RH equipment structures deformations under load in realtime to improve accuracy of virtual reality representation of RH equipment in the remote environment. The Structural Simulator requirements are provided in annex B of the RHCS Design handbook (RQ-B-052, RQ-B-054, RQ-B-057). [RQ-E-139] The Structural Simulator shall be capable of providing structural simulation calculations at a minimum rate of 2Hz with a maximum latency of 200msec and jitter of 50msec Interface [RQ-E-140] The Structural Simulator shall be compatible with the RH standard Desktop or Server Operating System. [RQ-E-141] Structural Simulator software that is specifically developed for IO shall be compatible with the RH standard Software Development Environment. [RQ-E-142] The Structural Simulator shall interface with the RH standard Virtual Reality system using the RH standard Communication Middleware. [RQ-E-143] The Structural Simulator shall interface with the RH equipment controllers or the Command & Control application for position and load updates using the RH standard Communication Protocol Standard Part ITER Organization 29
32 3.14 Synthetic Viewing System Function The Synthetic Viewing system provides optimized viewing of the remote environment based on a fusion of live sensor data and 3D model data. Synthetic Viewing is an element of the overall Viewing System and requirements are provided in annex B of the RHCS Design handbook (RQ-B-074) Interface [RQ-E-146] The Synthetic Viewing system shall interface with ITER 3D model data in order to load the RH equipment/tools and ITER environment models. [RQ-E-147] The Synthetic Viewing system shall interface with the RH standard Audio-Video Network to receive live streaming of environment sensing data. [RQ-E-148] The Synthetic Viewing system shall interface with the RH standard Audio-Video Network to output live streaming of optimized viewing images for display on RH standard Viewing Monitors. [RQ-E-149] The Synthetic Viewing system shall interface with the RH standard Control Network for sending/receiving control communications with the Viewing GUI and the camera sensor controllers. [RQ-E-150] The Synthetic Viewing system shall be compatible with the RH standard Communication Middleware and Communication Protocol for communication over the Control Network. [RQ-E-151] The Synthetic Viewing system shall be compatible with the RH standard Video Signal Distribution Protocol for communication over the Audio-Video Network Standard Part ITER Organization 30
33 3.15 Remote Diagnostic Function The Remote Diagnostic system is a high-level control system application that shall provide overall monitoring of RH equipment condition monitoring data and tools for assisting fault finding. The Remote Diagnostic requirements are provide in annex B of the RHCS Design handbook (RQ-B-063, RQ-B-064, RQ-B-065, RQ-B-066) Interface [RQ-E-152] The Remote Diagnostic system interface requirements are provide in annex B of the RHCS Design handbook (RQ-B-067, RQ-B-068, RQ-B-069, RQ-B-070). [RQ-E-153] The Remote Diagnostic system shall interface with the condition monitoring module of the RH equipment controllers over the RH Diagnostic Network. [RQ-E-154] The Remote Diagnostic system communications with the RH equipment controllers shall conform to the RH standard Communication Protocol. [RQ-E-155] The Remote Diagnostic system shall interface with CODAC for data archiving and retrieval Standard Part ITER Organization 31
34 3.16 Structured Language Function The Structured Language is a common language format to be adopted across all the RH equipment systems for programming RH operations (RQ-C-051). The Structured Language grammar and basic commands are provided in annex C of the RHCS Design handbook (section 4.2) Interface [RQ-E-156] The Structured Language shall be used within the Operations Management System for unambiguously recording RH task procedures. [RQ-E-157] The Structured Language shall be used within the Command & Control system for recording RH equipment automated sequences. [RQ-E-158] The Structured Language shall be compatible with tracking operations on the Virtual Reality system Standard Part ITER Organization 32
35 4 Low-Level Control System The low-level control system concerns the control cubicles that are typically located in dedicated cubicle rooms away from the hazardous environment. In some cases, the low-level control system can be distributed out to on-board controls. Each RH equipment system will contain a set of control cubicles for driving the RH equipment and tools. The RH low-level control system parts include:- Electrical Distribution Board Electrical Distribution Panel Cubicle External Connectors Penetration Connectors Field Cabling Real-Time Operating System Operating Framework RH Library On-Line Condition Monitoring Control Cubicle Products General Purpose Processor Board Control Unit Communication Bus Field Communication Bus General I/O Programmable Logic Controller Motion Controller Resolver Driver Strain Gauge Driver Camera Driver Auxiliary Joint Driver Main Joint Driver Heavy Duty Joint Driver Hydraulic Servo Valve Hydraulic Solenoid Valve Power Relay ITER Organization 33
36 4.1 Electrical Distribution Board Function [RQ-E-159] The Electrical Distribution Board shall connect to PBS 43 power from load centres and shall be capable of providing individually tripped power up to 25kVA for at least 30 loads. [RQ-E-160] The Electrical Distribution Board trip settings shall be configurable for each load. [RQ-E-161] The Electrical Distribution Board individual load supplies shall be lockable in the off position to allow safe maintenance of loads. [RQ-E-162] The Electrical Distribution Board shall comply with the low voltage standards defined in the Electrical Design Handbook [2] (see also EDH Guide A (ITER_D_2EB9VT)) Interface [RQ-E-163] The Electrical Distribution Board shall be self-standing and comply with the space reservation of 1000mm wide x 600mm deep x 2200mm height. [RQ-E-164] The interface between the Electrical Distribution Board and the power line from the load centre shall be as defined in the interface between PBS23 (Remote Handling) and PBS 43 (Steady-state power supply) Standard Part ITER Organization 34
37 4.2 Electrical Distribution Panel Function [RQ-E-165] The Electrical Distribution Panel shall connect to PBS 43 power from load centres and shall provide individually tripped power up to 25kVA for up to 10 loads. [RQ-E-166] The Electrical Distribution Panel trip settings shall be configurable for each load. [RQ-E-167] The Electrical Distribution Panel individual load supplies shall be lockable in the off position to allow safe maintenance of loads. [RQ-E-168] The Electrical Distribution Panel shall comply with the low voltage standards defined in the Electrical Design Handbook [2] (see also EDH Guide A (ITER_D_2EB9VT)) Interface [RQ-E-169] The Electrical Distribution Panel shall be wall mounted and comply with the space reservation of 600mm wide x 300mm deep x 800mm height. [RQ-E-170] The interface between the Electrical Distribution Board and the power line from the load centre shall be as defined in the interface between PBS23 (Remote Handling) and PBS 43 (Steady-state power supply) Standard Part ITER Organization 35
38 4.3 Cubicle External Connectors Function [RQ-E-171] The Cubicle External Connectors shall connect cubicles to the field cabling Interface [RQ-E-172] Cubicles for in-vessel operations shall interface with the standard cabling to the Cask service connectors in port cells Standard Part ITER Organization 36
39 4.4 Penetration Connectors Function [RQ-E-173] The Penetration Connectors shall provide remote handling compatible connectors for penetrations into red zones Interface [RQ-E-174] The Penetration Connectors shall be compatible with the design of the Hot Cell penetrations. [RQ-E-175] The Penetration Connectors shall be compatible with remote connect and disconnect by remote handling equipment Standard Part ITER Organization 37
40 4.5 Field cabling Function [RQ-E-176] The Field Cabling shall provide electrical connection between RH controllers and base connectors for RH equipment Interface [RQ-E-177] The Field Cabling shall be compatible with RH standards for connectors. [RQ-E-178] The Field Cabling shall be qualified for the environment conditions in which it will be deployed Standard Part ITER Organization 38
41 4.6 Real-Time Operating System (RTOS) Function [RQ-E-179] The Real-Time Operating System (RTOS) shall provide embedded computer operating system support to control system applications (computational processing, interrupt and timing services, networking services, file system access, peripheral device drivers). [RQ-E-180] The RTOS shall provide POSIX.1, POSIX.1b, and POSIX.1c functionality to control system applications. [RQ-E-181] The RTOS shall support deterministic timing with average interrupt latencies to user code of less than 70µsec for real-time processes. [RQ-E-182] The RTOS average jitter in the interrupt latency to user code shall be less than 30µsec. [RQ-E-183] The occurrence of interrupt latency greater than 100 µsec shall be less than 1 in (this is considered a missed deadline). [RQ-E-184] The occurrence of more than two consecutive missed deadlines shall be less than 1 in 10,000,000,000 (approximately a year of RH controller operation). [RQ-E-185] The RH controllers should be able to continue operation through 2 missed control cycles. The RH controllers should trip to safe state if the number of consecutive missed control cycles exceeds the controller safe limit, and in any case if 5 consecutive control cycles are missed Interface [RQ-E-186] The RTOS shall install on and interface with the RH General Purpose Processor Board. [RQ-E-187] The RTOS shall manage and facilitate application use of the embedded processor board hardware resources. [RQ-E-188] The RTOS shall be compliant with POSIX.1, POSIX.1b, and POSIX.1c for interfacing with RH control system applications. [RQ-E-189] The RTOS shall have an application development environment that is compatible with the RH Desktop Operating System Standard Part ITER Organization 39
42 4.7 Operating Framework Function [RQ-E-190] The Operating Framework is a software platform for the RH controllers that shall provide services in support of real-time modular control system applications. [RQ-E-191] The Operating Framework shall support a component oriented software engineering paradigm. [RQ-E-192] The Operating Framework shall support a separation of the following programming concerns:- Computation - to execute algorithms in modules running in a real-time framework, Communication - to communicate Process Data between modules, Configuration - to configure software modules (at run-time), Connection - to connect modules during deployment, Coordination - to orchestrate and monitor the execution of modules. [RQ-E-193] The Operating Framework shall provide a standard way to execute computations deterministically in a software module. [RQ-E-194] The Operating Framework shall provide a standard way of providing data inputs and outputs to computations. [RQ-E-195] The Operating Framework shall provide an abstraction of the interfaces to the underlying realtime operating system services. [RQ-E-196] The Operating Framework shall provide application components with an execution context. [RQ-E-197] The Operating Framework shall facilitate communication between application components. [RQ-E-198] The Operating Framework shall facilitate coordination of application components executing state machines (hierarchical state machine support, event handling, exposing of component operating states). [RQ-E-199] The Operating Framework shall offer tool support for component oriented application development (introspection, logging, monitoring, visualization, and code generation where possible). [RQ-E-325] The Operating Framework shall support components with the following interfaces:- Properties description and configuration of component internals Methods immediate calls, executed synchronously in caller execution context, Commands functions taking time, executed in components execution context, Events publishing of state changes, alarms, Dataflow support real-time streaming of data between components Interface [RQ-E-200] The Operating Framework shall be compatible with the RH standard for real-time operating system. [RQ-E-201] The Operating Framework shall be compatible with the RH standard for middleware communication. [RQ-E-202] The Operating Framework shall be compatible with development of RH applications using an RH standard programming language (Java/C/C++) Standard Part ITER Organization 40
43 4.8 RH Library Function [RQ-E-203] The RH library shall provide efficient small (dimension < 10) vector and matrix handling and operations. [RQ-E-204] The RH library shall provide common robotic mathematical functions:- Linear algebra, roots of polynomials, least squares fitting, B-splines, numerical differentiation, numerical integration, general vector and matrix operations, differential equations, random numbers. [RQ-E-205] The RH library shall provide common robotic calculation functions:- Position representation, coordinate frame transformations, rotations, representing robotic chains, forward kinematics, inverse kinematics, operations with velocities and forces (Jacobian), dealing with singularities, redundancies, solving robot dynamics, trajectory planning, interpolation in Cartesian space. [RQ-E-206] The RH library shall provide common signal conditioning functions:- Filtering and smoothing of signal data, deriving additional measurements from data, decomposing complex signal data into constituent parts Interface [RQ-E-207] The RH library module shall be compatible with the RH standard RTOS. [RQ-E-208] The RH library module shall be compatible with the RH standard operating framework component interfacing Standard Part ITER Organization 41
44 4.9 On-Line Condition Monitoring Function [RQ-097] The equipment controllers shall implement a condition monitoring system to continuously monitor equipment performance against nominal performance. [RQ-E-209] The on-line condition monitoring system shall continuously monitor equipment performance against nominal performance. [RQ-E-210] The on-line condition monitoring system shall report to high-level control system (events/alarms) regarding deviations from nominal performance. [RQ-E-211] The on-line condition monitoring system shall send equipment diagnostic data to the high-level control system at a minimum frequency of 3 Hz for archiving. [RQ-E-212] The on-line condition monitoring system shall provide functionality for configuring and running diagnostic tests. [RQ-E-213] The on-line condition monitoring system shall provide gathering of diagnostic data at high rates (minimum 20Hz) during diagnostic tests and afterwards sending the block of data to the high-level control system Interface [RQ-E-214] The on-line condition monitoring system shall be compatible with the RH standard for general purpose processing board (may be shared with control system or a dedicated processor board). [RQ-E-215] The on-line condition monitoring system shall operate as a software component separate from the equipment control system and interfacing through standard component interface structure. [RQ-E-216] The on-line condition monitoring system shall collect data (control signals, sensor feedback) from the control system where relevant for the condition monitoring functions. [RQ-E-217] The on-line condition monitoring system shall interface with the RH General I/O standard for gathering diagnostic data not available from the control system modules Standard Part ITER Organization 42
45 4.10 Control Cubicle Products Function [RQ-E-218] The control cubicle shall provide floor standing housing for the embedded controller parts. [RQ-E-219] The control cubicle shall provide electromagnetic protection. [RQ-E-220] The control cubicle shall provide ventilation. [RQ-E-221] The control cubicle shall provide full length access doors to the front and back of the cubicle. [RQ-E-222] The doors shall have locking by Front Securit key N o 405. [RQ-E-223] The control cubicle shall support mounting of external connectors on the top of the cubicle. [RQ-E-224] The control cubicle shall provide features to support transport of the cubicles. [RQ-E-225] The control cubicle shall have an external master switch for turning off the cubicle mains power. [RQ-E-226] The control cubicle shall provide an internal temperature measurement to the control system. [RQ-E-227] The control cubicle shall monitoring of the front and back door closed states. [RQ-E-228] The control cubicle shall provide a connection to earth. [RQ-E-229] The Electrical Distribution Board shall comply with the low voltage standards defined in the Electrical Design Handbook [2] (see also EDH Guide A (ITER_D_2EB9VT)) Interface [RQ-E-230] The control cubicle shall comply with space reservation of 0.8m x 0.8m base and 2.2m height. [RQ-E-231] The control cubicle shall provide support for 19 control system chassis modules. [RQ-E-232] The control cubicle shall provide cable trays for internal control system cable routing. [RQ-E-233] Door monitoring switches shall be compatible with 24V DC low current acquisition loop. [RQ-E-234] Cubicle temperature monitoring shall provide a 4-20mA current signal to control system Standard Part ITER Organization 43
46 4.11 General Purpose Processor Board Function [RQ-E-235] The General Purpose Processor Board shall provide computing services for RH control system applications (computational processing, memory, data storage, network interfacing, peripheral interfacing). [RQ-E-236] The General Purpose Processor Board shall provide board support package functionality allowing the operating system to interface with the processor board hardware Interface [RQ-E-237] The General Purpose Processor Board support package shall be compatible with the RH standard RTOS. [RQ-E-238] The General Purpose Processor Board shall provide output to support the connection of a computer monitor. [RQ-E-239] The General Purpose Processor Board shall provide at least one Ethernet connection. [RQ-E-240] The General Purpose Processor Board shall be compatible with the RH standard control unit communication bus. [RQ-E-241] The General Purpose Processor Board shall be compatible with a 4U chassis. [RQ-E-242] The General Purpose Processor Board shall be compatible with the CODAC Fast Controller platform (Fast Controllers Catalogue Datasheet - PICMG 1.3 PC 4U Industrial Computer (33ZH3R) ) Standard Part ITER Organization 44
Plant System I&C Architecture
IDM UID 32GEBH VERSION CREATED ON / VERSION / STATUS 06 Feb 2013 / 2.4/ Approved EXTERNAL REFERENCE Technical Specifications (In-Cash Procurement) Plant System I&C Architecture This technical note discusses
More informationElectrical Demand Specification (Reference SOP: )
Project: Equipment Description: Location: Equipment No.: Project No: Protocol No.: Content Index 1. GENERAL...3 Design Standards...3 1.1. Standards...3 2. DESIGN...3 2.1. Safety...3 2.2. Circuit protection...3
More informationAS-i Safety Relay Output Module with Diagnostic Slave
AS-i Safety Relay Output Module with Diagnostic Slave User Manual...supports the requirements for AS-i Safety up to SIL3 Revision date: 2016-03-9 Subject to modifications without notice. Generally, this
More informationTABLE OF CONTENTS. Page 2 14
TABLE OF CONTENTS INTRODUCTION... 3 WARNING SIGNS AND THEIR MEANINGS... 3 1. PRODUCT OVERVIEW... 4 1.1. Basic features and components... 4 1.2. Supply package... 5 1.3. Robot arm specifications... 6 1.4.
More informationStandard specifications RS007LFF60
Standard specifications RS007LFF60 December 05, 2017 KAWASAKI HEAVY INDUSTRIES, LTD. ROBOT DIVISION Materials and specifications are subject to change without notice. Specification : (Arm): (Controller):
More informationHand. Desk 4. Panda research 5. Franka Control Interface (FCI) Robot Model Library. ROS support. 1 technical data is subject to change
TECHNICAL DATA 1, 2 Arm degrees of freedom 7 DOF payload 3 kg sensitivity joint torque sensors in all 7 axes maximum reach 855 mm joint position limits A1: -170/170, A2: -105/105, [ ] A3: -170/170, A4:
More informationD115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors
D115 The Fast Optimal Servo Amplifier For Brush, Brushless, Voice Coil Servo Motors Ron Boe 5/15/2014 This user guide details the servo drives capabilities and physical interfaces. Users will be able to
More informationSPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station
SPI PowerNet requirements for the non-contestable Interface Works at Deer Park Terminal Station SPI PowerNet Reference: ZD23 Version: 1.1 Issue date: 15 May 2014 Contents 1 Scope... 3 2 Deer Park Terminal
More informationAS-i Safety Relay Output Module with Diagnostic Slave
AS-i Safety Relay Output Module with Diagnostic Slave User Manual Revision date: 2013-01-30...supports the requirements for AS-i Safety up to SIL3 Subject to modifications without notice. Generally, this
More information2. REAL-TIME CONTROL SYSTEM AND REAL-TIME NETWORKS
2. REAL-TIME CONTROL SYSTEM AND REAL-TIME NETWORKS 2.1 Real-Time and Control Computer based digital controllers typically have the ability to monitor a number of discrete and analog inputs, perform complex
More informationRT4F-110V/25A RECTIFIER
The RT4F-110V/25A is a hot-pluggable switched mode rectifier (SMR) module designed to provide up to 25A of output current into a 110V nominal system. Examples of such systems are 60 cells lead acid (136V
More informationEMS10 - EMS50. Cameo specification sheet. Product Description
Product Description Wall Mount Fist Microphones 10, 20 or 50 Selection Buttons EN54 Compliant Indicators and Controls EN54 Fault List Display Speech Level VU Bargraph Fully Monitored Hardware Bypass Fallback
More informationEM-F-7G Safety Extension Module
EM-F-7G Safety Extension Module One-channel control with four safety output channels Features Safety Extension Module provides additional safety outputs for a Primary Safety Device (for example, an E-stop
More informationHexapod Motion Controller with EtherCAT
Hexapod Motion Controller with EtherCAT Control a 6-Axis Positioning System via Fieldbus Interface C-887.53x Integration into an automation system Synchronous motion in 6 axes Cycle time 1 ms Commanding
More informationRT4B-110V/12A RECTIFIER
The RT4B-110V/12A is a switched mode rectifier (SMR) module designed to provide up to 12A of output current into a 110V nominal system. It can be used with or without a cooling fan. With a fan it runs
More informationUSER GUIDE. AXIS T8120 Midspan 15 W 1-port ENGLISH
USER GUIDE AXIS T8120 Midspan 15 W 1-port ENGLISH Legal Considerations Video and audio surveillance can be prohibited by laws that vary from country to country. Check the laws in your local region before
More informationTRACKER 240 SERIES. Load Cell and Weighing Indicators. A Precision Measurement Instrument with Outstanding Features
TRACKER 240 SERIES Load Cell and Weighing Indicators A Precision Measurement Instrument with Outstanding Features TRACKER 240 SERIES INDICATORS Ratiometric Measurement Tare and Auto Transducer Excitation
More informationOvation Ethernet Link Controller Module Data Sheet
Ovation Ethernet Link Controller Module Features: Provides native Ethernet connectivity capability at the I/O level Enables faster, more efficient integration of robust data from third-party devices Dedicated
More informationRT12-240V/2.4kW Rectifier Specification
The RT12-240V/2.4kW is a switched mode rectifier (SMR) module that delivers up to 2.4kW of output power (and up to 11A output current) into a 240V nominal DC system. The RT12 suits AC supply voltages between
More informationINTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS
INTRINSICALLY SAFE INSTRUMENTATION FOR HAZARDOUS AREAS SHORT FORM 2002 SERIES D1000 Intrinsically Safe Galvanic Isolators SERIES D1000, for DIN Rail Mounting, provide the most simple and cost effective
More informationRT4F-120V/20A-WAC RECTIFIER
The RT4F-120V/20A-WAC is a switched mode rectifier/charger module designed to provide up to 20A of output current into a 120V nominal system. This charger has been designed for use in conjunction with
More informationIndustrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter
/ S15 / Industrial RS-232/ RS-422/ RS-485 over Ethernet Media Converter Serial Interface One RS-232 port and one RS-422/485 port to one Base-FX Media Conversion Cost effective solutions of RS-232/ RS-422/
More informationUSB-L111. USB-L111 User Manual TPM. Version: V M05. To properly use the product, read this manual thoroughly is necessary.
USB-L111 USB-L111 User Manual Version: V1.0 2012M05 To properly use the product, read this manual thoroughly is necessary. Part No.: 81-0211100-010 1 Revision History Date Revision Description 2011/8/5
More informationSpecification Voltage Limiting Device
Engineering Specification Electrical Networks L1-CHE-SPE-152 Specification Voltage Limiting Device Version: 1 Issued: 20 th April 2018 Owner: Chief Engineer Approved By: Andrew Russack Head of Engineering,
More informationControl D. Controller Module for Proportional Valve Control. Installation Manual
Control D Controller Module Table of Contents Control D 1 1.1 1.2 1.3 1.3.1 1.3.2 1.4 2 3 4 5 5.1 5.2 5.3 6 7 8 Description 3 How To Order 3 Operating Elements 3 Adjustment 4 Operation 4 Auto-adapt 4 Operating
More informationOct Karl. A. Meier
ADVANCED Motion Controls Oct 2012 New motio on control system options utilizing EtherCAT technology Karl A. Meier Overview This document describes the evolution of motion and control system architectures
More informationStatus display unit with P-bus connection
8 917 DESIO TM I/O modules with P-bus connection PHM1.36TL for connections to automation stations with P-bus for status indication of up to 24 messages for remote control of up to 12 operating points in
More informationMulti-Axis Position Control by EtherCAT Real-time Networking
Multi-Axis Position Control by EtherCAT Real-time Networking Lecture Topics EtherCAT Applications Overview The EtherCAT Control Approach The EtherCAT Data Processing Time Synchronization Requirements in
More informationINDUSTRIAL CONTROL SYSTEMS & COMPUTER PROCESS CONTROL
1 INDUSTRIAL CONTROL SYSTEMS & COMPUTER PROCESS CONTROL INDUSTRIAL CONTROL - DEFINED The automatic regulation of unit operations and their associated equipment as well as the integration and coordination
More informationE Copyright VARAN BUS USER ORGANIZATION 06/2015. Real Time Ethernet VARAN Bus
8100000100-E Copyright BUS USER ORGANIZATION 06/2015 Real Time Ethernet Bus - Versatile Automation Random Access Network The bus system meets all requirements of a modern industry network optimized for
More informationProduct Specifications
Product Specifications VIBROCONTROL 6000 Monitoring System Description of Functionality Overview The VIBROCONTROL 6000 Monitoring System is used for both stand-alone machine protection and condition monitoring
More informationSIMADYN D Digital Control System. Fiber-Optic Rack Coupling CS12. User Manual. Edition DK No
SIMADYN D Digital Control System User Manual Fiber-Optic Rack Coupling CS12 Edition 05.95 DK No. 237741 User Manual, Fiber-Optic Rack Coupling CS12 Edition Status 1 Fiber-Optic Rack Coupling CS12 05.95
More informationELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS
ELECTRICAL, INSTRUMENTATION & CONTROL SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017 ELECTRICAL PLANT CONCEPT The electrical equipment, depending
More informationINTER PLANT STANDARD STEEL INDUSTRY
INTER PLANT STANDARD STEEL INDUSTRY PARTICULAR REQUIREMENTS OF ROLLING MILL VVVF DRIVES IPSS: 1-10-043-15 IPSS CORRESPONDING IS DOES NOT EXIST 0. FOREWORD 0.1 This Inter Plant Standard has been prepared
More informationController Cardax FT Controller The CardaxFT Controller 5000 is the intelligent field controller in the CardaxFT security system.
The features described in this data sheet are being progressively added to the CardaxFT Controller (5000 Series) during 2002/2003. Please contact Cardax for further information. Cardax FT Controller 5000
More informationProduct Manual. USB 2.0 Over IP Network Industrial 4-Port Hub TCP/IP Network. Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-4NET
USB 2.0 Over IP Network Industrial 4-Port Hub TCP/IP Network Product Manual Coolgear, Inc. Version 1.1 September 2017 Model Number: USBG-4NET 2 USBG-4NET Product Manual Revision History Revision Date Author
More informationGuidelines for diagnostic data structure and plant system status information
ITER_D_ 354SJ3 v. 2.1 Guidelines for diagnostic data structure and plant system status information Abstract This document provides guidelines for the data structure that should be used by diagnostic systems
More informationReal Time Control of the MIT Vehicle Emulator System
Proceedings of the 1991 American Control Conference June, 1991, Boston, MA Real Time Control of the MIT Vehicle Emulator System William K. Durfee, Husni R. Idris and Steven Dubowsky Department of Mechanical
More informationRVL470. Heating controller. G2522en. Installation Instructions. 1 Installation. 2 Commissioning Wall mounting DIN rail mounting
G2522en Heating controller Installation Instructions RVL470 1 Installation 1.1 Place of installation In a dry room, e.g. the boiler room Mounting choices: In a control panel (on the inner wall or on a
More informationSPOS (Station Point of Sale) 200. SFTP (Station Fare Transaction Processor) 35. CQD (Card Query Device) 35. HCR (Handheld Card Reader) Cradles 120
DESIGN GUIDELINES PRESTO INSTALLATION & CONNECTIVITY PAGE 1 of 4 ELECTRICAL CONNECTIVITY AND WIRING Communications Conduits Conduits designated for Presto equipment data wiring shall be clearly identified
More informationATV340D75N4E variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet
Characteristics variable speed drive - 75kW- 400V - 3 phases - ATV340 Ethernet Main Range of product Product or component type Device application Device short name Variant Product destination Mounting
More informationIV-30 Operating Manual for Pulse Distributor Cassette with potential separation
IV-30 Operating Manual for Pulse Distributor Cassette with potential separation Edition-/Rev.-Date: 09/08/2006 Document-/Rev.-No.: TR - EAK - BA - GB - 0093-02 Software version: - File name: TR-EAK-BA-GB-0093-02.DOC
More informationUser Manual CODAC Core System Overview
IDM UID 34SDZ5 VERSION CREATED ON / VERSION / STATUS 10 Feb 2014 / 4.2 / Approved EXTERNAL REFERENCE User Manual This document is an overview of the software distribution. It is a part of the documentation
More informationINSTALLATION MANUAL SLI 50 INVERTER
INSTALLATION MANUAL SLI 50 INVERTER www.unipowerco.com Manual No. SLI-50-48-3 2016 UNIPOWER LLC All Rights Reserved UNIPOWER LLC 3900 Coral Ridge Drive, Coral Springs, Florida 33065, USA sales@unipowerco.com
More information1.2 Intel Server Chassis SC5400BASE Summary
Introduction Intel Server Chassis SC5400BASE Customization Panels Unpainted Rack Top Cover Slim Line CDROM/USB Floppy Kit Intel Server Chassis SC5400BRP 10-pack Branding / Customization Panels Unpainted
More informationCODAC Core System Overview
IDM UID 34SDZ5 VERSION CREATED ON / VERSION / STATUS 26 Jun 2014 / 4.3 / Approved EXTERNAL REFERENCE User Manual This document is an overview of the software distribution. It is a part of the documentation
More information4 balanced inputs 1 relay output
Cardax FT Controller 5000GL provides flexible system architecture with options of GBUS and LOCAL BUS communications to field devices, to meet a wide range of site requirements. Cardax FT Controller 5000GL
More informationRT4F-48V/50A-WAC RECTIFIER
The RT4F-48V/50A-WAC is a switched mode rectifier (SMR) module designed to provide up to 58A of output current into a 48V nominal system, over a wide range of AC input voltage. This rectifier has been
More informationProduct specification Articulated robot
Product specification Articulated robot IRB 1600-5/1.2 IRB 1600-5/1.45 IRB 1600-7/1.2 IRB 1600-7/1.45 M2004 1 Description 1.1.1 Introduction Manipulator axes Axis 3 - Axis 4 + Axis 5 - + + - + - Axis 6
More informationOperating Manual FPGA-based High-Speed Micro-PLC
ZX20T Operating Manual FPGA-based High-Speed Micro-PLC Zander GmbH & Co. KG Am Gut Wolf 15 52070 Aachen, Deutschland info@zander-aachen.de www.zander-aachen.de Part No.: E61-335-10 Edition: H03 This document
More informationSIPROTEC 7SC805. Merging Unit for conventional instrument transformer. Products for digital substations.
Products for digital substations SIPROTEC 7SC805 Merging Unit for conventional instrument transformer Integrated PRP, HSR www.siemens.com/processbus built to create digital substations based on IEC 61850-9-2
More informationFL MC 2000T. Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections. Data sheet 3379_en_B
Fiber optic converter for 10/100Base-Tx to single- or multi-mode fiberglass with SC-duplex and ST connections Data sheet 3379_en_B 1 Description PHOENIX CONTACT 2015-07-14 2 Features Media converters provide
More informationMAINTENANCE MANUAL. EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS
MAINTENANCE MANUAL EDACS REDUNDANT POWER SUPPLY SYSTEM 350A1441P1 and P2 POWER MODULE CHASSIS 350A1441P3, P4, AND P5 POWER MODULES TABLE OF CONTENTS SPECIFICATIONS*... 2 INTRODUCTION... 3 DESCRIPTION...
More informationOperating instructions. ProcessLine analogue module AC / / 2012
Operating instructions ProcessLine analogue module AC2916 739089 / 01 06 / 2012 Contents 1 Safety instructions... 3 2 Functions and features... 4 3 Operating and display elements... 4 4 Electrical connection...
More informationTitle Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units. Reference Number SPS 30 - (RIC Standard: SC SP)
Discipline Engineering Standard - NSW Category Signalling Title Power Supply Units for Signalling Equipment - DC (Regulated & Filtered) Units Reference Number SPS 30 - (RIC Standard: SC 09 10 07 00 SP)
More informationRemoval of Hardware ESD, Independent of Safety Logic Solver
Removal of Hardware ESD, Independent of Safety Logic Solver by Sam Roy Executive summary This is a discussion to remove independent hardware based Emergency Shutdown for Logic Solver as identified in ANSI/ISA-84.00.01-2004,
More informationDS2020SingleAxis ExtremelyCompact ServoDrives
DS2020SingleAxis ExtremelyCompact ServoDrives INTRODUCTION If you need the best performance and design flexibility, look no further than Moog and its expertise. With collaboration, creativity and cutting-edge
More informationMotion Controller. MXC Series Multi-Axis Motion Controller Compact Motion Controller with up to 6 Axes of Control
MXC Series Multi-Axis Motion Controller Compact Motion Controller with up to 6 Axes of Control Allied Motion s MXC motion controller is a very compact, multi-axis servo and/or step motor motion controller,
More informationHDC MK2 Digital Control for Rigging System
HDC MK2 Digital Control for Rigging System WALL MOUNTED VERSION PDA WiFi FEATURES The HDC MK2 is a Rigging Control System utilized for either direct control of simple motorized rigging products or fully
More informationStride Industrial Ethernet Switches
8-Port Ethernet Switch with Fiber Port STRIDE Industrial Ethernet Switch with eight 10/100BaseT RJ45 Ethernet ports and one 100BaseFX Fiber optic port (ST type multimode fiber connector for links up to
More information1. The camera shall be 20fps Resolution and be 25 fps resolution for advances picture quality supporting 25fps.
Technical specification for CCTV system: 1- Indoor Fixed Full HD Cameras 1. The camera shall be 3MP @ 20fps Resolution and be 2MP @ 25 fps resolution for advances picture quality supporting H.264 @ 25fps.
More informationREDUNDANCY MODULE TSP-REM360 AND TSP-REM600
REDUNDANCY MODULE TSP-REM360 AND TSP-REM600 Operating Instructions Seite 1 Dimensions drawings: TSP-REM360 Weight: 0.882lb Gewicht: 0.40kg Seite 2 Dimensions drawings: TSP-REM600 Bottom view Top view Side
More informationA P P L I C A T I O N
Circuit Breaker timing test set 16 timing channels Motion and speed analyzer Built-in 200 A microohmmeter Up to 4 trip/close coils control Static and dynamic contact resistance measurement Suitable for
More informationRobotEye RELW60. High Speed Long Wave Infra-Red Thermal Imaging System User Manual
RobotEye RELW60 High Speed Long Wave Infra-Red Thermal Imaging System User Manual. Unit F1, 13-15 Forrester St Kingsgrove NSW 2208 Australia ii Copyright Notice and Disclaimer Copyright 2015 ( Ocular Robotics
More informationQUICK START GUIDE PC-MCAT 64
ETHERCAT 100 BASE-T ETHERNET (GIG-E) STATUS LED S HDMI OUTPUT USB (X4) DUAL INPUT, POWER BATTERY COVER CHASSIS EARTH SCREW QUICK START GUIDE PC-MCAT 64 P760 00 Safety Warning During the installation or
More informationAutomation innovations in material handling. Smart solutions to meet logistics challenges
Automation innovations in material handling Smart solutions to meet logistics challenges Urbanization, connectivity everywhere, e-commerce, and mass personalization are reshaping the landscape in manufacturing
More informationAS-i Safety Relay Output Module with Diagnostic Slave, 1 EDM, 1 x 2 channel Safe Input
ext. in ext. in AS-i Safety Relay Output Module with Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V Additionally 1 EDM input, 1 x
More informationMODERN /CONTROLROOMS THE FINDING A SOLUTION THAT WORKS FOR THE WAY YOU WORK
THE MODERN CONTROL ROOM FINDING A SOLUTION THAT WORKS FOR THE WAY YOU WORK BLACKBOX.COM /CONTROLROOMS CONTROL ROOM SIGNAL FLOW SOURCES SIGNAL MANAGEMENT OPERATOR CONSOLES VIDEO WALL MAIN CONTROL ROOM Video
More information1. Introduction. 2. Design. Safety and Emergency Stop Circuit Design Standard. Safety and Emergency Stop Circuit Design Standard.
Safety and Emergency Stop Circuit Design Standard The Safety and Emergency Stop Circuit Design Standard provide design criteria and specifications for safety and emergency stop circuits used in General
More informationFiber optic converter audio and CAN TA OPERATION MANUAL
Fiber optic converter audio and CAN TA-110.1 IOA110-1 March 2009 LANEX S.A., Technical support: tel. ul.ceramiczna 8, 20-150 Lublin tel. +48 81 443 96 36 Contents 1. General Characteristics.... 5 1.1.
More informationATS-16 HV USER MANUAL. Automatic Transfer Switch 16A / 230Vac V090318
ATS-16 HV Automatic Transfer Switch 16A / 230Vac USER MANUAL V090318 SAFETY Intended use The ATS-16 HV device serves as a power source selector to provide improved power supply for connected loads. ATS-16
More informationNETRONICS HS3500 CONTROLLER
NETRONICS HS3500 CONTROLLER CUSTOMER NAME CONTROLLER SERIAL # CONTROLLER PART # PERSONALITY SWITCH SETTINGS BULLET PRESS CONFIGURATION DELIVERY DATE Contact the factory for help setting up your application.
More informationOperating instructions. Switching amplifier DN0210 DN / / 2015
Operating instructions Switching amplifier DN0210 DN0220 UK 80011079 / 00 01 / 2015 Contents 1 Preliminary note...4 1.1 Symbols used...4 1.2 Warning signs used...4 2 Safety instructions...5 2.1 General...5
More informationRhino Redundancy Module PSM24-REM360S. Operating Instructions
Rhino Redundancy Module PSM4-REM360S Operating Instructions RHINO REDUNDANCY MODULE PSM4-REM360S Description With this module and two power supplies of the PSM series (78, 90, 56, 80 and 360 watt models),
More informationI/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications
I/A Series Remote Terminal Unit (RTU) RTU 20 for Oil, Gas, and Water SCADA Applications RTU 20 OVERVIEW The I/A Series RTU 20 is an Intelligent Remote Device capable of performing a full range of control
More informationTABLE OF CONTENTS. Page 2 35
TABLE OF CONTENTS INTRODUCTION... 3 WARNING SIGNS AND THEIR MEANINGS... 3 1. ABOUT THE PULSE ROBOT... 4 1.1. The hardware and software... 4 1.2. The operating states of the PULSE robot... 5 1.3. Safe operation
More informationMESP TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V DC TRACTION SYSTEM
Engineering Specification Electrical Networks TECHNICAL SPECIFICATION FOR A RECTIFIER UNIT CONTROL & PROTECTION SYSTEM FOR USE IN THE 1500V Version: 1 Issued: March 2014 Owner: Electrical Networks Asset
More informationC x Hexapod Motion Controller
C-887.52x Hexapod Motion Controller Compact Bench-Top Device for Controlling 6-Axis Systems Sophisticated controller using vector algorithms Commanding in Cartesian coordinates Changes of the reference
More informationIntegrated Control & Drive Solution
Integrated Control & Drive Solution Fusion Introducing FUSION, an integrated elevator control and drive solution that provides superior performance through S-curve technology, and significantly reduces
More informationFL MC 2000E (SM40) LC
IEC 61850 fiber optic converter with LC fiber optic connection (1310 nm) to convert 100Base-Tx to single- or multi-mode fiber glass Data sheet 3205_en_C 1 Description PHOENIX CONTACT 2014-04-04 2 Features
More informationDrive Control via EtherNet/IP using CIP Motion and CIP Sync Profile Extensions
Drive Control via EtherNet/IP using CIP Motion and CIP Sync Profile Extensions High-Performance Closed Loop Drive Control Using EtherNet/IP 2 This session will discuss why Industrial Ethernet is emerging
More informationATV32HU30N4 variable speed drive ATV32-3 kw V - 3 phase - with heat sink
Characteristics variable speed drive ATV32-3 kw - 400 V - 3 phase - with heat sink Complementary Line current Apparent power Prospective line Isc Nominal output current Maximum transient current Speed
More informationMODERN /CONTROLROOMS THE FIND A SOLUTION THAT WORKS FOR THE WAY YOU WORK
THE MODERN CONTROL ROOM FIND A SOLUTION THAT WORKS FOR THE WAY YOU WORK BLACKBOX.COM /CONTROLROOMS CONTROL ROOM SIGNAL FLOW SOURCES SIGNAL MANAGEMENT OPERATOR CONSOLES VIDEO WALL MAIN CONTROL ROOM Video
More informationCONTENTS INTRODUCTION. System overview...2. Axis module...3 Interface...3 Technical characteristics and environmental data...4 Dimensions...
DS2020Si ngl eaxi s Ext r emel ycompact Ser vodr i ves INTRODUCTION If you need the best performance and design flexibility, look no further than Moog and its expertise. With collaboration, creativity
More informationHigher Availability: Self-diagnostics. Automatically tests unit electronics and batteries. Designed to simplify maintenance and troubleshooting.
UPS operation and display panel can rotate 90 degrees, which provides upright viewing for users. Liebert GXT3 UPS Includes These Outstanding Features: Flexibility: Rack/tower configuration. The versatile
More informationAS-i Safety Relay Output Module with Diagnostic Slave and 1 EDM Input
Safety + standard I/O in one module Safety relay output with galvanically isolated contact sets, approved up to 230 V IEC 61508 SIL 3, EN ISO 13849-1/PLe Kat 4, EN 62061 SIL 3 Protection category IP20
More informationPD 527 Valve Control Module PD Series 600. Product Data Sheet February 2015 SD E06
PD 527 Valve Control Module PD Series 600 Product Data Sheet February 2015 SD 8719-2E06 PD 527 Valve Control Module February 2015 Introduction The PD 527 Valve Control Module is specially designed to control
More informationHow to Choose the Right Bus for Your Measurement System
1 How to Choose the Right Bus for Your Measurement System Overview When you have hundreds of different data acquisition (DAQ) devices to choose from on a wide variety of buses, it can be difficult to select
More informationWatchmaker precision for robotic placement of automobile body parts
FlexPlace Watchmaker precision for robotic placement of automobile body parts Staff Report ABB s commitment to adding value for customers includes a constant quest for innovation and improvement new ideas,
More informationVAMP 221. Table of Contents
2 V221/EN M/E019 VAMP 221 Table of Contents Table of Contents 1. General... 7 1.1. VAMP 221 arc protection system components... 7 1.1.1. Central unit VAMP 221... 9 1.1.2. I/O units VAM 12L / VAM 12 LD,
More informationDrive inverter for asynchronous AC motors without encoder feedback. The units are not option capable.
MDX61B System overview MOVIDRIVE MDX60B/61B is the new generation of drive inverters from SEW EURODRIVE. The new series B MOVIDRIVE drive inverters, which feature a modular design, provide enhanced functions
More informationPROFINET The leading communication system
Titel einer Beispielpräsentation PROFINET The leading communication system Proven and future-oriented PROFINET 2 3 4 Market & Applications PROFINET overview 0 Reasons for PROFINET Industrie 4.0 and PROFINET
More informationChloride CROSS Rack 16 A, 32 A and 63 A
AC Power for Business-Critical Continuity Chloride CROSS Rack 16 A, 32 A and 63 A STS Catalogue Chloride CROSS Rack High Voltage and Low Voltage 2 Pole Complete Reliability On-line Static Switch 16 A,
More informationDrive and Control Systems: Technical Update. John A. Looser Faustel, Incorporated
Drive and Control Systems: Technical Update John A. Looser Faustel, Incorporated Coating and Laminating Equipment Key Control Areas Variable Speed Drives Programmable Logic Controllers (PLC) Human Machine
More informationS7316: Real-Time Robotics Control and Simulation for Deformable Terrain Applications Using the GPU
S7316: Real-Time Robotics Control and Simulation for Deformable Terrain Applications Using the GPU Daniel Melanz Copyright 2017 Energid Technology Overview 1. Who are we? 2. What do we do? 3. How do we
More informationMaking Hazardous Operations Safe and Productive
NEW Safety Guard Switching Unit G9SX-GS Making Hazardous Operations Safe and Productive Making Hazardous Operations Safe and Productive This new addition to the model of Flexible Safety Unit G9SX series
More informationPROFIBUS. Sharani Sankaran
PROFIBUS Sharani Sankaran fq8610@wayne.edu Outline Introduction TransmissionTechnologies Communication Protocol Application Profiles Integration Technologies Technical Support INTRODUCTION: Field buses
More informationSMARTSCAN INFORMATION
SMARTSCAN INFORMATION SL4 (014) SERIES SAFETY LIGHT CURTAINS HANDBOOK Smartscan Ltd, Pywell Road, CORBY, NN17 5XJ, UK, Tel: +44 (0) 1536 401313, Fax: +44 (0) 1536 268954, Email: sales@smartscan.co.uk,
More information1000Base-SX / LX to 10/100/1000Base-T 802.3at PoE Industrial Media Converter
Base-SX / LX to 10/100/Base-T 802.3at Industrial Media Converter Physical Port PLANET IGTP-80xT Industrial Gigabit Media Converter series combines Ethernet media conversion (from Base-X to 10/100/Base-T)
More informationOperating instructions. Standstill monitor A / / 2011
Operating instructions Standstill monitor A300 UK 1 2 3 4 5 6 7 8 7390337 / 01 02 / 2011 1 2 3 4 5 6 7 8 switchpoint min max pulse/min power Made in Germany ifm electronic gmbh D 45127 Essen func. I II
More information